Loading...
HomeMy WebLinkAbout18423 HAWKSVIEW DR_BLD6670_2026 RESIDENTIAL BUILDING PERMIT APPLICATION Community and Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223 • Phone (360) 403-3551 The following information is required for Residential: Single Family, Duplex, Townhomes, Additions, and Accessory Structure Building Permit Applications. Mark each box to designate that the information has been provided. Please submit this checklist as part of the submittal documents. EACH BUILDING OR STRUCTURE REQUIRES A SEPARATE SUBMITTAL. Incomplete applications will not be accepted. SUBMIT ELECTRONIC FILES FOR EACH OF THE FOLLOWING: REQUIRED DOCUMENTS Proof of approved Zoning Verification City of Arlington Residential Permit Application Site Plan Architectural Plans Structural Plans Structural Calculations Project Specification Manuals, if applicable WSEC Compliance Forms https://waenergycodes.com/ Special Inspection and Testing Agreement, if applicable Deferred Submittal Request, if applicable 1. Plan Review fee is due at time of submittal and remaining balance will be due at time of issuance. 2. The City of Arlington does not review or inspect electrical systems. Contact Labor and Industries at lni.wa.govor 360-416-3000. A. DEFERRED SUBMITTALS If the project requires any of the following, a Deferred Submittal Request MUST be completed. Deferred submittals require separate applications, plans and plan review. 1. Mechanical Plans (if not included in the plan set) 2. Plumbing Plans (if not included in the plan set) 3. Fire Sprinkler B. SPECIAL INSPECTION AND TESTING AGREEMENT A Special Inspection Firm is required to perform special inspections for the following type of work. *The Special Inspection and Testing Agreement MUST be submitted with the Building Application. Structural Masonry Spray-Applied Fireproofing Other - Specify: ____________________  I acknowledge that all items designated as submittal requirements must accompany my Building Permit Application to be considered a complete submittal. RESIDENTIAL BUILDING Type of Permit: Single-family Duplex Townhouse  Addition/Alteration Accessory Structure IBC Construction Type: 3 IBC OccupancyType: R3 BuildingSquare Footage: 3315 Number of Stories: 2 Square Footage Per Floor: B: 756 1st:1600 2nd: 3rd: Garage: 595 PropertyAddress: 18423 Hawksview Drive, Arlington Project Valuation: 725000 Lot #: 20 Parcel ID No.: 008983-000-020-00 Preferred Contact:  Owner  Contractor Project Finishing basement space by adding interior walls, flooring, and insulation. Scope of Work: Owner Name: Kyle Scott Home No.: Email Address: kylegscott94@gmail.com Cell No.: 4254265630 MailingAddress: 18423 Hawksview Dr City: Arlington State: WA Zip: 98223 PrimaryContractor: Office No.: Email Address: Cell No.: MailingAddress: City: State: Zip: L&I Contractor License Number: Expiration Date: MECHANICAL SYSTEM INFORMATION  Not Applicable Type of Permit:  New Installation  Addition/Alteration/Repair  Gas Piping Mechanical Contractor: Office No.: Email Address: Cell No.: MailingAddress: City: State: Zip: L&I Contractor License Number: Expiration Date: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances REV03.2022 Page 2 of 6 RESIDENTIAL BUILDING MECHANICAL PERMIT FEES (per unit) Type of Fixture No. of Units Cost per Unit Subtotal Model No. Additional Plan Review fees x $ 75.00 = Air Cond. Unit ≤100Btu /h x $ 15.00 = Air Cond. Unit >100Btu/h x $ 25.00 = Air Cond. Unit >500Btu/h x $ 50.00 = Air HandlingUnits x $ 15.00 = Base Mechanical Fee 1 x $ 25.00 = $ 25.00 Boiler <100Btu/h >3hp x $ 15.00 = Boiler >1 million Btu/h<50hp x $ 25.00 = Boiler >1.5 million Btu/h<50hp x $ 50.00 = Boiler >100Btu/h 3-15hp x $ 15.00 = Boiler >500Btu/h 15-30hp x $ 25.00 = Diffusers x $ 15.00 = Dryer Ducting x $ 15.00 = Ductwork(drawings required) x $ 25.00 = Evaporative Coolers x $ 15.00 = Exhaust/Ventilation Fans x $ 15.00 = Fireplace/Insert/Stove x $ 15.00 = Forced Air Heat ≤100 Btu /h x $ 15.00 = Forced Air Heat >100 Btu/h x $ 25.00 = Gas Clothes Dryer x $ 15.00 = Gas Fired AC ≤100 Btu /h x $ 15.00 = Gas Fired AC >100 Btu/h x $ 25.00 = Gas Fired AC > 500 Btu/h x $ 50.00 = Gas Piping≤ 5 units x $ 15.00 = Gas Piping> 5 units(plus <5 units) x $ 2.00 = Heat Exchangers x $ 15.00 = Heat Pump-CondensingUnit x $ 25.00 = Hot Water Heat Coils x $ 15.00 = Miscellaneous Appliance - regulated by $ 15.00 x = mechanical code, not otherwise specified Pkg. Units ≤100btu x $ 25.00 = Pkg. Units >100btu x $50.00 = Range/Cook top-Gas Fired x $ 15.00 = Refrigeration Unit ≤100Btu/h x $ 15.00 = Refrigeration Unit >100Btu/h x $ 25.00 = Refrigeration. Unit >500Btu/h x $ 50.00 = Re-inspection fee x $ 75.00 = Residential Range Hood x $ 15.00 = Unit Heaters ≤ 100 Btu /h x $ 15.00 = Unit Heaters >100 Btu/h x $ 25.00 = VAV Boxes (Variable Air Volume, part of air $ 10.00 x = conditioningsystem) Wall Heaters - Gas Fired x $ 25.00 = Water Heater - Gas Fired x $ 25.00 = Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total REV03.2022 Page 3 of 6 RESIDENTIAL BUILDING GAS PIPING INFORMATION  Not Applicable Proposed Piping Material: CSST Brass Galvanized Steel Black Steel  Other _______________ Proposed Piping Size: ½” ⅝” ¾” 1” 1½” 2” Distance from Meter to furthest Appliance: Total BTU’s of all Appliances: PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY – USE A SEPARATE SHEET, IF NECESSARY  SCHEMATIC IS TO SCALE  SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated REV03.2022 Page 4 of 6 RESIDENTIAL BUILDING PLUMBING SYSTEM INFORMATION  Not Applicable Type of Permit:  New Installation  Addition/Alteration/Repair PlumbingContractor: Office No.: Email Address: Cell No.: MailingAddress: City: State: Zip: L&I Contractor License Number: Expiration Date: • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) • Cross-Connection-Control may be required Proposed Interior Water Piping Size: ½” ⅝” ¾” 1” CPVC Brass PEX-AL-PEX PEX Proposed Interior Piping Material: Copper Galvanized Steel Other _______________________ Proposed Exterior Water Piping Size: ½” ⅝” ¾” 1” 1½” 2” PVC Copper PEX-AL-PEX PEX-AL-PE Proposed Exterior Piping Material: PE PEX Other Schedule 40 ABS DWV Copper Galvanized Steel Cast Iron Proposed Drain-Waste-Vent (DWV) Material: Schedule 40 PVC DWV Brass Other: ________________________________ Proposed Drain-Waste-Vent (DWV) ½” ⅝” ¾” 1” 1½” 2” 3” 4” Piping Size: PLUMBING PERMIT FEES (per fixture) Type of Fixture No. of Fixtures Costper Fixture Subtotal Additional Plan Review fees x $ 75.00 = Alteration/repairpiping x $ 15.00 = Backflow Assembly x $25.00 = Base PlumbingFee 1 x $ 25.00 = $25.00 Bath/Shower Combo x $ 15.00 = BuildingMain Waste x $ 25.00 = Clothes Washer x $ 15.00 = Dishwasher x $ 15.00 = Floor Drains x $ 15.00 = Grease Interceptor x $ 75.00 = Grease Trap x $ 25.00 = Hose Bibb x $ 15.00 = REV03.2022 Page 5 of 6 RESIDENTIAL BUILDING PLUMBING PERMIT FEES (per fixture) Icemaker/Refrigerator x $ 15.00 = Irrigation – per meter x $ 25.00 = Kitchen Sink & Disposal x $ 15.00 = LaundryTray x $ 15.00 = Lavatory x $ 15.00 = Miscellaneous – regulated by plumbing code, not x $ 15.00 = otherwise specified Re-inspection Fee x $ 75.00 = Roof Drains x $ 15.00 = Shower(only) x $ 15.00 = Sink(bar, service, etc.) x $ 15.00 = Toilets x $ 15.00 = Urinal x $ 15.00 = Vacuum Breakers x $ 25.00 = Water Heater x $ 25.00 = MODEL NO.: Water Heater – Tankless x $ 25.00 = MODEL NO.: Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total I hereby certify that I am the  Owner Architect Engineer Contractor and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above- described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. Kyle Scott 08/11/25 Signature Print Name Date SAVE PRINT REV03.2022 Page 6 of 6 2021 WSEC-R 2nd Edition Remodel / Alteration Worksheet Will you be exposing the walls? Will the roof/ceiling framing cavities or attic be exposed? Will the will the floor framing cavities be exposed? Yes No Yes No Yes No If yes, If yes, If yes, 2 X 4 wall studs require R-15 insulation Exposed roof or ceiling assemblies must be insulated - Exposed floor cavities must be insulated to R-30 Vaulted ceilings, Insulate to the full depth of the 2 X 6 wall studs require R-21 insulation framing member If siding is replaced C.I. equal to R-5 may need installed Flat ceilings, install R-60 insulation or what the under the siding. attic space can accommodate based on the roof pitch Are more than 10% of the light fixtures being Are the windows and/or doors being replaced? Will the heating or cooling system be replaced? Will the hot water system be altered? changed? Yes No Yes No Yes No Yes No If yes, If yes, If yes, If yes, New equipment must meet current New water heating equipment must New windows and doors (+frames) must 100% of all lamps must be high requirements and the ducts need to be meet current code requirements have an area weighted average U-factor of efficacy tested ≤0.30 R503.2 Change in space conditioning. Any non-conditioned or low-energy space that is altered to become conditioned space shall be required to be brought into full compliance with this (WSEC-R) code. R503.1.1 Building envelope. Building envelope assemblies that are part of the alteration shall comply with Section R402.1.3 or R402.1.5, Sections R402.2.1 through R402.2.11, R402.3.1, R402.3.2, R402.3.5 and R402.4.2. Exception: The following alterations need not comply with the requirements for new construction provided the energy use of the building is not increased: 1. Storm windows installed over existing fenestration. 2. Existing ceiling, wall or floor cavities exposed during construction provided that these cavities are filled with insulation. 2x4 framed walls shall be insulated to a minimum of R-15 and 2x6 framed walls shall be insulated to a minimum of R-21. 3. Construction where the existing roof, wall or floor cavity is not exposed. 4. Roof recover. 5. Roofs without insulation in the cavity and where the sheathing or insulation is exposed during reroofing shall be insulated either above or below the sheathing. 6. Surface-applied window film installed on existing single pane fenestration assemblies to reduce solar heat gain provided the code does not require the glazing fenestration to be replaced. R503.1.1.1 Replacement fenestration. Where some or all of an existing fenestration unit is replaced with a new fenestration product, including sash and glazing, the replacement fenestration unit shall meet the applicable requirements for U-factor and SHGC in Table R402.1.3. Where more than one replacement fenestration unit is being installed, an area-weighted average of the U-factor and SHGC of all replacement fenestration shall be permitted to be used to demonstrate compliance. R503.1.2 Heating and cooling systems. New heating, cooling and duct systems that are part of the alteration shall comply with Section R403. Exceptions: 1. Where ducts from an existing heating and cooling system are extended, duct systems with less than 40 linear feet in unconditioned spaces shall not be required to be tested in accordance with Section R403.2.2 2. Existing duct systems constructed, insulated or sealed with asbestos. R502.1.1.2 Heating and cooling systems. New heating, cooling and duct systems that are part of the addition shall comply with Section R403. Exception: The following need not comply with the testing requirements of Section R403.3.3: 1. Additions of less than 750 square feet. 2. Duct systems that are documented to have been previously sealed as confirmed through field verification and diagnostic testing in accordance with procedures in WSU RS-33. 3. Ducts with less than 40 linear feet in unconditioned spaces. 4. Existing duct systems constructed, insulated or sealed with asbestos. R503.1.4 Lighting. New lighting systems that are part of the alteration shall comply with Section R404.1. Exception: Alterations that replace less than 10 percent of the luminaires in a space, provided that such alterations do not increase the installed interior lighting power. R503.1.3 Service hot water systems. New service hot water systems that are part of the alteration shall comply with Section R403.5. Permit #: 6670 Permit Date: 08/11/25 Permit Type: RESIDENTIAL ALTERATION Project Name: Scott Finishing Basement Applicant Name: Kyle Scott Applicant Address: 18423 Hawksview DR Applicant, City, State, Arlington, WA, 98223 Zip: Contact: Kyle Scott Phone: 4254265630 Email: Kylegscott94@gmail.com Scope of Work: Finishing basement space by adding interior walls, flooring, and insulation. A total of 756 sq being worked on Valuation: 25000.00 Square Feet: 3315 Number of Stories: 2 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 09/19/2025 Permit Expires: 04/20/2026 Form Permit Type: RESIDENTIAL ALTERATION Status: COMPLETE Assigned To: Kristin Foster Property Parcel # Address Legal Description Owner Name Owner Phone Zoning SCOTT 100 SINGLE 00898300002000 18423 HAWKSVIEW DR KYLE/SCOTT FAMILY JEREMY RESIDENCE Contractors License Contractor Primary Contact Phone Address Contractor Type License # 18423 Hawksview Kyle Scott OWNER Dr Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status R20. 02/02/2026 ADDITION/ALTERATION 02/03/2026 02/03/2026 BUILDING Approved FINAL 10/06/2025 R10. FRAMING 10/07/2025 10/07/2025 BUILDING Approved 10/20/2025 R11. INSULATION 10/20/2025 BUILDING Approved Plan Reviews Date Review Type Description Assigned To Review Status RESIDENTIAL Approved with 08/11/2025 See red lined drawings BUILDING ALTERATION Conditions RESIDENTIAL Development 08/11/2025 No civil comments Approved ALTERATION Services Manager RESIDENTIAL 08/11/2025 No land use concerns. PLANNING Approved ALTERATION Fees Fee Description Notes Amount Building Plan Review Table 4-2 $381.06 Credit Card Service $11.43 Processing/Technology $25.00 Building Permit Table 4-1 $586.24 State Surcharge - 1st DU Residential - 1st Unit $6.50 Credit Card Service $18.53 Total $1,028.76 Attached Letters Date Letter Description 09/19/2025 Building Permit 08/11/2025 Web Form - Building Application Payments Date Paid By Description Payment Type Accepted By Amount 08/11/2025 Kyle G 239764565 Hannah Hardwick $11.43 XBP Conf: 08/11/2025 $381.06 239764565 09/05/2025 Jeremy Scott 242162239 Hannah Hardwick $18.53 XBP Conf: 09/05/2025 $617.74 242162239 Outstanding Balance $0.00 Notes Date Note Created By: 09/18/2025 Emailed the owner the Affidavit in Lieu of Contractor form to complete. Kristin Foster 09/17/2025 Emailed for contractor information. Kristin Foster Uploaded Files Date File Name 09/19/2025 28375242-20250811_BLD6670_Approved FloorPlan.pdf 09/19/2025 28375240-20250919_BLD6670_IssuedPermit.pdf 08/11/2025 27749376-20250811_BLD6670_Application.pdf 08/11/2025 27749378-20250811_BLD6670_WSEC.pdf