Loading...
HomeMy WebLinkAbout340 E Burke Ave_BLD5698_2025 i Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 591h Avenue NE • Arlington,WA 98223 • Phone (360)403-3551 Permit Number: BLD5698 Permit Type: Residential Plumbing Address/Parcel: 340 E Burke Ave Completed (Month/Year): EXPIRED May 2024 Land Use ❑ Notice of Decision ❑ Bonding or Assignment of Funds ❑ Staff Report o Confidential Documents. Contact the ❑ Application City to obtain. ❑ Narrative ❑ Letters and Project Documents ❑ Legal Description ❑ Other: ❑ Vicinity Map ❑ Site Plan Civil ❑ Landscape Plan ❑ Issued Permit ❑ Complete Streets Checklist ❑ Application ❑ Traffic Impact Analysis ❑ Other Applications ❑ Snohomish County Traffic Mitigation Offer ❑ Construction Calculation Worksheet ❑ WSDOT Traffic Offer Form ❑ Approved Plans ❑ Tree Survey ❑ Review Comment Form ❑ Stormwater Drainage Report ❑ Letters and Project Documents ❑ Geotech Report ❑ Other Agency Permits ❑ Critical Area Evaluation Form ❑ Reports: ❑ SEPA Checklist o Drainage Report Pg: ❑ Public Notice Material o Stormwater Pg: ❑ Noticing and Related Documents o Geotech Pg: ❑ Water/Sewer Availability Certificate o All Other Reports ❑ Unanticipated Discovery Plan Form ❑ SEPA and Noticing Materials ❑ Aerial Photo of Site ❑ Inspections ❑ Proposed Building Materials ❑ As-Builts ❑ Lighting Plans and Lighting Cut Sheets ❑ Other: ❑ Color Elevations ❑ Design Matrix Building ❑ Plat Map ❑✓ Issued Permit ❑ Title Report ❑✓ Application ❑ Lot Closures ❑ Additional Applications ❑ Preliminary Civil Plans ❑ Approved Plans ❑ Archaeological Survey ❑ Site Plan o Confidential Documents. Contact the ❑ Letters and Project Documents City to obtain. ❑ Calculations ❑ Topography(Existing Conditions) ❑✓ Project Specification Manuals ❑ CC&R's ❑ Reports ❑ Deeds/Easements/Conveyances ❑ Certificate of Occupancy /Dedications ❑ Inspections ❑ Developer's Agreement ❑ Other: ❑ Recorded Copies Page 1 of 1 H O D '-' o r-)-tro o w -0 G7 o 07 C7 ~d r cn o td Q b w R x a H G� CD A n < CD v x a s oo o °O i , 77M � O ID Z 0ID * �by t o CrJ y � d0 p � � o m < Z o0 z �Z�11 to b ° � p tr O D z �Mn g tTlt7' CD , C] CD co Q N v� M � � CD .� n tr � � H C z Z x o � � CD W rD CD t7 n a ° o Z M O �MO � K o n o 0CD .� �, �• � o � y b � n n o o c cn CD D o CD CD o w iD v, r o o o o CD w O CD 0 o a o M dCD CD C,) o r 0 CD .; UQ O O Y M [ I10 M D o cD w C3 7 (7 C7 O O d �" t LT1 o CD td Z Z o CD �•, C "'� O,C �, O " O C r ni tr' CD Cn aD o C0.D o t" d Y C y O Ua n p- cu o v '' rri O Z a c 'Rho Q , CD z Sri C�r1 O C a rD ' cAo _ o0 Z n o 0 � w 7 w a ' Cd n ? o rn Q y 00 �� ri o w o � w 7y n "o �' x o � m '* CD D M Z ?» a o CD OH w O 0-4w SD o trc � w Z o x o nL.< ° w < M °° C7 Z M v' �C w n cr a, C. o ` Y C � � o y 00 CD � t7 H n_ �z cD C CDCD �1 M C G CDcn p Ili 1� � 4 y C7 y UQUQ ; ; ; ; d a C) > Y - r cn cn cn cn r d U r" d CD ° M N N N W 0 '•°7 > r o T M ate. nj . Cs, o - D C .i CIO CA w CD cn 2 � n V] p c G w D n O r° CDcwu x n O c " ` v W a c 7� O z N o PO CD Caw � C� Z b �,qti o M 70 w oo N m o (IQ CD o o _ � � M w o. C � o .o Dg YD LD �- H ° Od O a r O d-c-, ° o2 `° o IQ d < o - z Z .2 ov O 7� � M � CD ° T1 C ro M ac o71 O ° o D,O p-ti .- o �» d ° z rD CD Orri eD �] MdM Z O 7y p cu cu O7 7 r M M -� ° C is w M C w w R p rp EL E4 5. C G C 7j M (D <j do `1 D D C"D rD ?r cn o -n co M C w crD n CD CD M ma o ,c°o, M D O a o o Y o M � M 0. < �n CD q w ^rb d O o A z ° a D ° c o M cro o' v b CD D b d Ld (D m L, G a C/ :' C o ro No ° z 6A C/i Vl N N N W O O O C, cn U1 cn rD N O O O o 0 0 o p M O O O O o 0 6 0 -- RESIDENTIAL PLUMBING APPLICATION Community and Economic Development — City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 •Phone(360)403-3551 This application is for new,repaired,altered or replaced plumbing installation for existing residences. Please fill out all pages of this application and include all information. The City of Arlington does not require a permit to stop leaks or clear stoppages,unless the piping is repaired,altered or replaced. Type of Permit: ❑ New Installation ❑ Addition 0 Alteration ❑ Repair Property Address: 340 E BURKE AVE, UNIT 3 Project Valuation: 2516 Lot#: Parcel ID No.: 00461801400100 Preferred Contact: ❑ Owner O Contractor Project Description:REM OVE/REPLACE ELECTRIC WATER HEATER Owner Name: KRISTOPHER KRAMER/ DELTA PM Home No.: 360-659-7032 Email Address: maintenance@deltapropertymgmt.com Cell No.: Mailing Address: 316 PIONEER RD City: ELLENBORO State. NC Zip:28040 Contractor Name: FAST WATER HEATER Office No.: 425-636-7054 Email Address: permits@faStwaterheater.COrl1 Cell No.: Mailing Address: 11715 N CREEK PKWY S#C106 City: BOTH ELL State: WA Zip:98011 L&I Contractor License Number: FASTWWH948BC Expiration Date: 1/4/24 • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) • Cross-Connection-Control maybe required Proposed Interior Water Piping Size: ❑ 1h" ❑ 5/e" ❑ 3/4" ❑ 1" Proposed Interior Piping Material: ❑CPVC ❑ Brass ❑ Copper ❑ PFX-AL-PEX ❑ PEX ❑ Galvanized Steel ❑ Other Proposed Exterior Water Piping Size: ❑ 1/2" ❑ s/8" ❑ 3/4" ❑ 1" ❑ 11h" 112 Proposed Exterior Piping Material: ❑PVC ❑PE ❑ Copper ❑ PEX-AL-PEX ❑ PEX-AL-PE ❑ PEX ❑ Other Proposed Drain-Waste-Vent(DWV) ❑ Schedule 40 ABS DWV ❑ Copper ❑ Galvanized Steel ❑ Cast Iron Material: ❑ Schedule 40 PVC DWV ❑ Brass ❑ Other Proposed Drain-Waste-Vent(DWV) ❑ 1/z" ❑ s/s" ❑ 3/4" 1711 ❑ 11/z" ❑ 2" ❑ 3" 1714" Piping Size: PLUMBING PERMIT FEES (per fixture) Type of Fixture No.of Fixtures Cost per Fixture Subtotal Additional Plan Review fees x $75.00 = Alteration/repair piping x $15.00 = BackflowAssernbly x $25.00 = Base Plumbing Fee 1 x $25.00 = $25.00 Bath Shower Combo x $15.00 = Building Main Waste x $25.00 = Clothes Washer x $15.00 = Dishwasher x $15.00 = REV03.2022 Pagel of 2 PLUMBING PERMIT FEES (per fixture) Drinking Fountain x $15.00 = Floor Drains x $15.00 = Grease Interceptor x $75.00 = Grease Trap x $25.00 = Hose Bibb x $15.00 = Icemaker Ref'ri erator x $15.00 = -irrigation-per meter x $25.00 = Kitchen Sink&Disposal x $15.00 = -Laundry Tray x $15.00 = -Lavatory x $15.00 = Med Gas Pi in <-5 inlets outlets x $60.00 = Med Gas Piping>5 inlets/outlets(plus 15 5 x $5.00 = inlets outlets Miscellaneous-regulated by plumbing code,not x $15.00 = otherwise specified Pretreatment Interceptor x $15.00 = -Re-inspection Fee x $75.00 = Roof Drains x $15.00 = Shower(only) x $15.00 = Sink bar,service,etc. x $15.00 = Toilets x $15.00 = Urinal x $15.00 = Vacuum Breakers x $25.00 = Water Heater 1 x $25.00 = MODEL NO.: PROE50 MS RH CG Water Heater-Tankless x $25.00 = MODEL NO.: Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total I hereby certify that I am the❑Owner, ❑Applicant, ❑Contractor,and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington,and the City ofArlington.A final inspection and approval shrill be obtained when complete. ANTHONY DANESE 11/15/23 Signat Print Name Date SAVE PRINT REV03.2022 Page 2 of 2 Residential Electric ' Water Professional Classic Demand Response Ready Water Heaters The new degree of comfort' Professional Classic° Electric Demand Response Ready high efficiency water heaters are engineered for longer life and connection to utility demand response programs for energy savings Efficiency Easy to Install and Service li j -i • .92- .93 UEF • Durable brass drain valve helps • Dual 4500 and 5500 watt copper drain the tank faster to reduce time heating elements on the job Performance Plus... • FHR: 51 -72 gallons, based on gallon • EverKleen°self cleaning device fights capacity harmful sediment build-up with a • Recovery: 17 to 21 GPH at a 90° F high-velocity spiraling water stream— helps operating efficiency by saving rise, depending on model*** energy, money and improving tank life Longer Life \� • Premium grade anode rod provides 1 ' long-lasting tank protection ,r Features • User friendly interface on unit to easily i II adjust set temperature • Error code functionality triggers an audio alert to help prevent potential •Temperature and pressure relief water heater downtime valve included •Offers self-diagnostic control systems Warranty with LED lights indicating service is needed •6-Year limited tank and parts warranty* • Demand response ready EcoPort'M (CTA-2045 port) is built in for easy •With ProtectionPlus°the 6-year limited connect to utility demand response tank warranty becomes 10 year programs 'See Residential Warranty Certificate for complete information • High performance and lower operating cost Units meet or exceed ANSI requirements and have been tested according to D.O.E.procedures.Units Professional Classic • Electric junction box located above meet or exceed the energy efficiency requirements Electric Demand heating elements for easy installation of NAECA,ASHRAE standard 90,ICC Code and all state energy efficiency performance criteria. Response Ready •Over-temperature protector cuts off power in excess temperature 36 - 55-Gallon Capacities situations 240 Volt AC/Single Phase Electric LEED Point=1 See specifications chart on back. INTEGRATED HOME COMFORT 09/23 FORM NO.PROE RH HEDR Rev.2 Residential Electric ' w Water Professional Classic Demand II � Response Ready Water Heaters The new degree of comfort® Professional Classic° Electric Demand Response Ready Specifications DESCRIPTION FEATURES ROUGHING IN DIMENSIONS(SHOWN IN INCHES) ENERGY INFO. T UNIFORM Y NOMINAL RATED FIRST HOUR RECOVERY TANK HEIGHT TO APPROX. ENERGY P GALLON GALLON MODEL RATING IN G.P.H. HEIGHT WATER CONN. DIAMETER SHIP WE FACTOR E CAPACITY CAPACITY NUMBER (GALLONS) 90'F RISE A B C (LBS.) (UEF) Tall 40 36 PROE40 T2 RH CG 55 21 60-3/4 63-5/8 18-1/4 108 0.92 Tall 50 45 PROE50 T2 RH CG 63 21 58-1/2 61-3/4 20-1/4 124 0.92 Tall 55 55 PROE55 T2 RH CG 72 21 57 59-3/4 22-1/4 131 0.92 Med. 40 36 PROE40 M2 RH CG 55 21 48-3/8 50-1/2 20-1/4 109 0.93 Med. 50 45 PROE50 M2 RH CG 63 21 48 50-1/2 22-1/4 131 0.92 Short 38 35 PROE38 S2 RH BCG** 51 21 31-1/2 32-5/8 23 ill 0.92 Short 36 33 PROE36 S2 RH CG 51 21 31-1/2 33 24-1/4 121 0.92 Short 47 43 PROE47 S2 RH CG 54 21 32 34 26-1/4 152 0.92 Uniform Energy Factor and rated gallon capacity based on Department of Energy(DOE)requirements. a^� •Heaters furnished with standard 240 volt AC,single phase non-simultaneous wiring,and 4500 watt upper and lower heating elements. •Also available in 5500 watt upper and lower heating elements.If heating elements of different wattages than those shown are demanded, HOT WATER O COLD WATER they must be specifically requested. CONNECTION CONNECTION **Insulation blanket required to achieve UEF value.Water heater dimensions prior to installing insulation blanket. Blanket is included with water heater. i sl O Recovery=wattage/2.42 x temp.rise°F. Example: 450OW =21 GPH 2.42 x 90° ECOPORT ANODE (CTA-2045 PORT) ROD —Recovery calculations used are based on 4500 watt elements used in non-simultaneous operation. O LEED Point-1 B C� A 9 WATER CONNECTIONS ALL 3/4"N.P.T. In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway,Suite 100 Roswell,Georgia 30076 • www.rheem.com INTEGRATED HOME COMFORT 09/23 FORM NO.PROE RH HEDR Rev.2