Loading...
HomeMy WebLinkAbout8021 Vista Dr_BLD5680_2025 i Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 591h Avenue NE • Arlington,WA 98223 • Phone (360)403-3551 Permit Number: BLD5680 Permit Type: Residential Mechanical Address/Parcel: 8021 Vista Dr Completed (Month/Year): EXPIRED April 2024 Land Use ❑ Notice of Decision ❑ Bonding or Assignment of Funds ❑ Staff Report o Confidential Documents. Contact the ❑ Application City to obtain. ❑ Narrative ❑ Letters and Project Documents ❑ Legal Description ❑ Other: ❑ Vicinity Map ❑ Site Plan Civil ❑ Landscape Plan ❑ Issued Permit ❑ Complete Streets Checklist ❑ Application ❑ Traffic Impact Analysis ❑ Other Applications ❑ Snohomish County Traffic Mitigation Offer ❑ Construction Calculation Worksheet ❑ WSDOT Traffic Offer Form ❑ Approved Plans ❑ Tree Survey ❑ Review Comment Form ❑ Stormwater Drainage Report ❑ Letters and Project Documents ❑ Geotech Report ❑ Other Agency Permits ❑ Critical Area Evaluation Form ❑ Reports: ❑ SEPA Checklist o Drainage Report Pg: ❑ Public Notice Material o Stormwater Pg: ❑ Noticing and Related Documents o Geotech Pg: ❑ Water/Sewer Availability Certificate o All Other Reports ❑ Unanticipated Discovery Plan Form ❑ SEPA and Noticing Materials ❑ Aerial Photo of Site ❑ Inspections ❑ Proposed Building Materials ❑ As-Builts ❑ Lighting Plans and Lighting Cut Sheets ❑ Other: ❑ Color Elevations ❑ Design Matrix Building ❑ Plat Map ❑✓ Issued Permit ❑ Title Report ❑✓ Application ❑ Lot Closures ❑ Additional Applications ❑ Preliminary Civil Plans ❑ Approved Plans ❑ Archaeological Survey ❑ Site Plan o Confidential Documents. Contact the ❑ Letters and Project Documents City to obtain. ❑ Calculations ❑ Topography(Existing Conditions) ❑✓ Project Specification Manuals ❑ CC&R's ❑ Reports ❑ Deeds/Easements/Conveyances ❑ Certificate of Occupancy /Dedications ❑ Inspections ❑ Developer's Agreement ❑ Other: ❑ Recorded Copies Page 1 of 1 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 8021 VISTA DR Permit#:5680 Parcel#:00904500004200 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:REMOVE/REPLACE GAS WATER HEATER Valuation:2333.00 OWNER APPLICANT CONTRACTOR MARLA BROWN FAST WATER HEATER FAST WATER HEATER CO. 8021 VISTA DR 11715 N Creek PKWY S#C106 12601 132ND AVE ARLINGTON,WA 98223-4013 Bothell KIRKLAND,WA 98034 4256367054 800-454-8985 LIC:602 564 544 EXP:05/31/2024 LIC:FASTWWi3948BC E(P:01/04=4 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2018 STORIES: 2 CONST.TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC I10/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 11/01/2023 �Vicant Signature Date Building Official Date CONDITIONS Adhere to approved mechanical equipment. Call for final inspection.Permit shall be onsite for inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 01/22/2024 Processing/Technology $25.00 01/2212024 Inspecton $75.00 01/2212024 K/bchanical Base $25.00 01/22=4 Water Heater-LPG $25.00 01/22/2024 Credit Card Seruce $4.50 Total Due: $154.50 Total Payment: $154.50 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail RESIDENTIAL MECHANICAL APPLICATION Community and Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit: ❑ New Installation 0 Addition/Alteration/Repair ❑ Gas Piping Property Address: 8021 VISTA DR Project Valuation: 2333 Lot#: Parcel ID No.: 00904500004200 Preferred Contact: ❑ Owner O Contractor Project Description: REMOVE/REPLACE GAS WATER HEATER Owner Name: MARLA BROWN Home No.: 425-359-9957 Email Address: Cell No.: Mailing Address: 8021 VISTA DR City:ARLINGTON State: WA Zip:98223 Contractor Name: FAST WATER HEATER Office No.: 425-636-7054 Email Address: permits d@fastWatef heater Cell No.: Mailing Address: 11715 N CREEK PKWY S 4C106 City,. BOTH ELL State: Zip:WA 98011 L&I Contractor License Number: FASTWWH948BC Expiration Date: 1/4/24 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information ❑ Not Applicable ❑ css-r ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ 1/2" ❑ 5/8" ❑ 3/4" ❑ 1" ❑ 11/2" ❑ 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: MECHANICAL PERMIT FEES (per unit) Type of Fixture No.of Units Cost per Unit Subtotal Model No. Additional Plan Review fees x $75.00 = Air Cond.Unit<_100Btu h x $15.00 _ Air Cond.Unit>10OBtu h x $25.00 = Air Cond.Unit>50013tu h x $50.00 = Air Handling Units x $15.00 = Base Mechanical Fee 1 x $25.00 = $25.00 ;q Boiler<10013tu h>3h x $ 15.00 = Boiler>1 million Btu/h<50hp x $25.00 = REV03.2022 Page 1 of 2 MECHANICAL PERMIT FEES (per unit) Boiler>1.5 million Btu/h<50hp x $50.00 = Boiler>100Btu h 3-15h x $15.00 = Boiler>500Btu h 15-30hp x $25.00 = Commercial Hoods-Type 1 x $25.00 = Commercial Hoods-Type 11 x $50.00 = Diffusers x $15.00 = Dryer Ducting x $15.00 = Ductwork(drawings required) x $25.00 = Evaporative Coolers x $15.00 = Exhaust Ventilation Fans x $15.00 = Fire lace Insert Stove x $15.00 = Forced Air Heat<_100 Btu h x $15.00 = Forced Air Heat>100 Btu h x $25.00 = Gas Clothes Dryer x $15.00 = Gas Fired AC<_100 Btu h x $15.00 = Gas Fired AC>100 Btu h x $25.00 = Gas Fired AC>500 Btu h x $50.00 = Gas Piping:'5 units x $15.00 = Gas Piping>5 units (plus<5 units x $2.00 = Heat Exchangers x $1S.00 = Heat Pump-Condensing Unit x $25.00 = Hot Water Heat Coils x $15.00 = Miscellaneous Appliance-regulated by x $15.00 = mechanical code,not otherwise specified Pkg.Units<_100btu x $25.00 = Pkg.Units>100btu x $50.00 = Range/Cook top-Gas Fired x $15.00 = Refrip,eration Unit s100Btu h x $15.00 = Refrigeration Unit>100Btu h x $25.00 = Refrigeration.Unit>500Btu h x $50.00 = Re-inspection fee x $75.00 = Residential Range Hood x $15.00 = Unit Heaters 15 100 Btu h x $15.00 = Unit Heaters>100 Btu h x $25.00 = VAV Boxes(Variable Air Volume,part of air x $10.00 conditioning system) Wall Heaters-Gas Fired x $25.00 = Water Heater-Gas Fired x $25.00 = Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total REV2.2020 Page 2 of 2 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE M SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated I hereby certify that I am the Owner, [:]Applicant, M.nrtractor, and authorized to sign this application and that the above information is correct and construction on,and the occupy rr-v and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington,and the City of Arlington.A final inspection and approval shall be obtained when complete. ANTHONY DANESE 11/1 /23 Signatur Print Name Date SAVE PRINT REV2.2020 Page 3 of -( r _� � 1 C -� qft pp71YN Drawingforloh#: (' Address J77,4rw�.ws Customer I73 - New Water Piping -----New 1—NOR IWwl.nM ssLootion 0.17 7 Modelri Water Heater BTU's Total Feet of Gas Line Outdoor Dist to Property Line PERFORMANCE PLUS --------- - WTVIF TT 0 The new degree of comfort® The PERFORMANCE PLUS° atmospheric gas water heaters are engineered for more ' hot water at a low operating cost Efficiency Longer Life .58- .65 UEF ■Premium grade anode rod provides Performance long-lasting tank protection ■FHR: 68-81 gallons High Altitude Compliant ■Recovery: Up to 40.4 GPH at a ■All models certified up to 8,500 ft. 90'F rise, depending on model above sea level, some models certified up to 10,200 ft.See Diagnostic Valve specifications chart'" ■Self powered diagnostic Plus... gas control valve for • improved monitoring ■Easy to light—no matches required and service ■Temperature and pressure relief valve Low Emissions included ■Eco-friendly burner, low NOx design ■Low lead compliant ■Meets 40 ng/J NOx requirements Warranty ■9-Year limited warranty for tank Self-Cleaning and parts, 2-year full in-home labor ■Fights sediment and warranty" mineral build-up `See written warranty for complete details ■Reduces fuel costs Units meet or exceed ANSI requirements and have .. been tested according to D.O.E.procedures.Units Maintenance Free meet or exceed the energy efficiency requirements Burner System of NAECA,ASHRAE standard 90,ICC Code and all state energy efficiency performance criteria. ■Exclusive air/fuel shut-off device PERFORMANCE PLUS ■Maintenance free—no filter to clean Atmospheric ■Disables the heater in the presence of 40 and 50-Gallon Capacities flammable vapor accumulation Up to 40,000 Btu/h 7 " MI on Combustion Shut-of System Flame Arrestor Plate O UO Maintenance Free tEED Point=i See specifications chart on back. 12/20 FORM NO.THD-P+HE Rev.5 1 1 The new degree of comfort® PERFORMANCE PLUS" Atmospheric Gas S• - • Ht to Water Water7(LBS) (UEF)y rm Nominal Rated Gas Input Recovery First Hour Ht.to Tank Gas Vent Conn. Ht.to Side Conn. g Gallon Gallon Model in Thous. in G.P.H. Rat ing Vent Height Diam. Conn. Size Center T&PValve Size or juel.,T,pe Description Capacity Capacity Number Btu/h 9-F Rise (Gallons) A B C D E F G H Tall 50 48 XG50T0911l 40 40.4 77 62-3/4 59-1/4 21-1/2 14 3or4 8 52-1/2 3/4 165 0.64 Tall 40 38 XG40T09HE4000** 40 40.4 81 63-3/4 60-1/4 19-1/2 14 3 or4 8 53-1/2 3/4 135 0.65 Short 40 39 XG40S09HE38U0** 38 38.4 68 53-3/4 50-1/4 21-1/2 14 3 8 44 3/4 125 0.58 Tall 50 48 XP50T09HE36U0 36 36.4 77 62-3/4 59-1/4 21-1/2 14 3 or 8 52-1/2 3/4 165 0.64 Tall 40 38 XP40T09HE36U0** 36 36.4 81 63-3/4 60-1/4 19-1/2 14 3 or4 8 53-1/2 3/4 135 0.65 Short 40 39 XP40S09HE36U0** 36 36.4 68 53-3/4 50-1/4 21-1/2 14 3 8 44 3/4 125 0.58 Uniform Energy Factor and rated gallon capacity based on Department of Energy(DOE)requirements. **Models certified up to 12,500 ft.above sea level. FLUE O ANODEROD *. 0 HOT O H WATER COLD LEED Point 1 CONNECTION WATER- 1 1 1 1 CONNECTION 1 1 ' F '1 1 it E If 3/4" N.P.T. RELIEF VALVE OPENING 0 C l4 B 1/2" G D In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway,Suite 100 Roswell,Georgia 30076 • www.rheem.com 12/20 FORM NO.THD-P+HE Rev.5