HomeMy WebLinkAbout3911 174th Pl Ne_BLD5746_2025 i
Permit Packet Coversheet
Community and Economic Development
City of Arlington • 18204 591h Avenue NE • Arlington,WA 98223 • Phone (360)403-3551
Permit Number: BLD5746 Permit Type: Residential Mechanical
Address/Parcel: 3911 174th PI Ne Completed (Month/Year): February 2024
Land Use
❑ Notice of Decision ❑ Bonding or Assignment of Funds
❑ Staff Report o Confidential Documents. Contact the
❑ Application City to obtain.
❑ Narrative ❑ Letters and Project Documents
❑ Legal Description ❑ Other:
❑ Vicinity Map
❑ Site Plan Civil
❑ Landscape Plan ❑ Issued Permit
❑ Complete Streets Checklist ❑ Application
❑ Traffic Impact Analysis ❑ Other Applications
❑ Snohomish County Traffic Mitigation Offer ❑ Construction Calculation Worksheet
❑ WSDOT Traffic Offer Form ❑ Approved Plans
❑ Tree Survey ❑ Review Comment Form
❑ Stormwater Drainage Report ❑ Letters and Project Documents
❑ Geotech Report ❑ Other Agency Permits
❑ Critical Area Evaluation Form ❑ Reports:
❑ SEPA Checklist o Drainage Report Pg:
❑ Public Notice Material o Stormwater Pg:
❑ Noticing and Related Documents o Geotech Pg:
❑ Water/Sewer Availability Certificate o All Other Reports
❑ Unanticipated Discovery Plan Form ❑ SEPA and Noticing Materials
❑ Aerial Photo of Site ❑ Inspections
❑ Proposed Building Materials ❑ As-Builts
❑ Lighting Plans and Lighting Cut Sheets ❑ Other:
❑ Color Elevations
❑ Design Matrix Building
❑ Plat Map ❑✓ Issued Permit
❑ Title Report ❑✓ Application
❑ Lot Closures ❑ Additional Applications
❑ Preliminary Civil Plans ❑ Approved Plans
❑ Archaeological Survey ❑✓ Site Plan
o Confidential Documents. Contact the ❑ Letters and Project Documents
City to obtain. ❑ Calculations
❑ Topography(Existing Conditions) ❑✓ Project Specification Manuals
❑ CC&R's ❑ Reports
❑ Deeds/Easements/Conveyances ❑ Certificate of Occupancy
/Dedications ❑ Inspections
❑ Developer's Agreement ❑ Other:
❑ Recorded Copies
Page 1 of 1
CITY OF ARLINGTON
18204 59th Avenue NE,Arlington,WA 98223
INSPECTIONS:360-403-3417-Permit Center:360-403-3551
BUILDING PERMIT
3911 174TH PL NE Permit#:5746
Parcel#:00934700002500 PERMIT EXPIRES 180 DAYS AFTER
DATE OF ISSUANCE.
Scope of Work:REMOVE/REPLACE GAS WATER HEATER Valuation:3161.00
OWNER APPLICANT CONTRACTOR
AZGHANDI MASOUD V/RAFATNIA FAST WATER HEATER FAST WATER HEATER CO.
SHAHRZAD
3911 174TH PL NE 16120 WOODINVILLE-REDMOND RD 12601 132ND AVE
NE „
ARLINGTON,WA 98223-3704 WOODINVILLE,WA 98072 KIRKLAND,WA 98034
4256367054 800-454-8985
LIC:602 564 544 EXP:OS/31/2024
LIU FAST V WF1<?48BC EXP:011O 2024
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
LIC#: EXP: LIC#: EXP:
,JOB DESCRIPTION
PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2018
STORIES: 0 CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any
other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the
Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any
period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice
or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid. The building official is
authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or
any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or
decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or
on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or
federal law,or any order,proclamation,guidance or decision of the Governor.
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK
AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE
STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND
ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN
MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110.
SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on
your sales tax return form and coded City of Arlington#3101.
12/21/2023
pplicant Signature Date Building Official Date
CONDITIONS
ADHERE TO THE INSTALLATION OF THE APPROVED APPLIANCE.APPROVED JOB COPY SHALL BE ONSITE
FOR INSPECTION.CALL FOR INSPECTION.
The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property
owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or
community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities
before commencing construction.The property owner shall ensure that the construction project complies with all applicable design
review requirements.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE
PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,
MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
01/05/2024 Processing/Technology $25.00
01/05/2024 Inspection $75.00
01/05=4 Nechanical Base $25.00
01/05/2024 Water Heater-LPG $25.00
01/05/2024 Credit Card Service $4.50
Total Due: $154.50
Total Payment: $154.50
Balance Due: $0.00
CALL FOR INSPECTIONS
Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
INSPECTION INFORMATION I Pass/Fail
i
RESIDENTIAL MECHANICAL APPLICATION
Community and Economic Development
City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 •Phone(360)403-3551
This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping.
Please fill out all pages of this application and include all information.
Type of Permit: ❑ New Installation ❑✓ Addition/Alteration/Repair ❑ Gas Piping
Property Address: 3911 174TH PL NE Project Valuation: 3161
Lot#: Parcel ID No.: 00934700002500 Preferred Contact: ❑ Owner O Contractor
Project Description: REMOVE/REPLACE GAS WATER HEATER
Owner Name:
MASOUD VATANPOUR Home No.: 425-753-1103
Email Address: Cell No.:
Mailing Address: 3911 174TH PL NE City:ARLINGTON State: WA Zip:98223
FAST WATER HEATER 425-636-7054
Contractor Name: Office No.:
Email Address: permits@fastwaterheater.com Cell No.: `
Mailing Address. 15120WOODWWILLE REDMOND RD NE,STE 15 City: WOODINVILLE State: WA Zip:
L&I Contractor License Number: FASTWWH948BC Expiration Date: 1/4/24
• New gas piping requires a pressure test hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper Combustion air and venting required for all appliances
• A shut-off valve is required within 6 feet of all appliances
Gas Piping Information ❑ Not Applicable
❑CSST ❑ Brass ❑ Other
Proposed Piping Material:
❑ Black Steel ❑ Galvanized Steel
Proposed Piping Size: ❑ 1h" ❑ 5/s" ❑ 3/4" ❑ 1" ❑ 11/2" ❑ 2"
Distance from Meter to furthest Appliance: Total BTU's of all Appliances:
MECHANICAL PERMIT FEES (per unit)
Type of Fixture No.of Units Cost per Unit Subtotal Model No.
Additional Plan Review fees x $75.00 =
Air Cond.Unit<_100Btu h x $15.00 =
Air Cond.Unit>100Btu h x $25.00 =
Air Cond.Unit>50013tu h x $50.00 =
Air Handling Units x $15.00 =
Base Mechanical Fee 1 x $25.00 = $25.00111111111111111111
Boiler<10013tu/h>3h x $15.00 = 77
Boiler>1 million Btu h<50h x $25.00 =
REV03.2022 Pagel of 2
MECHANICAL PERMIT FEES (per unit)
Boiler>1.5 million Btu/h<50hp x $50.00 =
Boiler>100Btu h 3-15h x $ 15.00 = _
Boiler>500Btu h 15-30hp x $25.00 =
Commercial Hoods-Type I x $25.00 =
Commercial Hoods-Type I1 x $50.00 =
Diffusers x $15.00 =
Dryer Ducting x $15.00 =
Ductwork(drawings required) x $25.00 =
Evaporative Coolers x $15.00 =
Exhaust Ventilation Fans x $15.00 =
Fireplace/Insert/Stove x $15.00 =
Forced Air Heat<_100 Btu h x $15.00 =
Forced Air Heat>100 Btu h x $25.00 =
Gas Clothes Dryer x $15.00 =
Gas Fired AC 5100 Btu h x $15.00 =
Gas Fired AC>100 Btu h x $25.00 =
Gas Fired AC>500 Btu h x $50.00 =
Gas Pi in 5 5 units x $15.00 =
Gas Piping>5 units(plus<5 units x $2.00 =
Heat Exchangers x $15.00 =
Heat Pump-Condensing Unit x $25.00 =
Hot Water Heat Coils x $15.00 =
Miscellaneous Appliance-regulated by x $15.00 =
mechanical code,not otherwise specified
Pkg.Units 15100btu x $25.00 =
Pkg.Units>100btu x $50.00 =
Range/Cook top-Gas Fired x $15.00 =
Refrigeration Unit<_100Btu h x $15.00 =
Refrigeration Unit>100Btu h x $25.00 =
Refrigeration.Unit>500Btu h x $50.00 =
Re-inspection fee x $75.00 =
Residential Range Hood x $15.00 =
Unit Heaters<_ 100 Btu h x $15.00 =
Unit Heaters>100 Btu h x $25.00 =
VAV Boxes(Variable Air Volume,part of air x $10.00 =
conditioning system)
Wall Heaters-Gas Fired x $25.00 =
Water Heater-Gas Fired x $25.00 =
Permit Fee
Inspection Fee $75.00
Processing/Technology Fee $25.00
Total
REV2.2020 Page 2 of 2
PRESSURE PIPING SCHEMATIC
COMPLETE FOR GAS PIPING ONLY
SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE
Show Pipe Size(s) and Length(s) from meter to all appliances
NOTE: Any interior pressure regulators must be indicated
I hereby certify that I am the ❑Owner, ❑Applicant ❑Contractor, and authorized to sign this application and that the above
information is correct and construction on,and the occupancy and the use of the above-described property will be in accordance with
the laws, rules and regulation of the State of Washington, and the City of Arlington.A final inspection and approval shall be obtained
when complete.
Are ANTHONY DANESE 12/21 /23
Signatur Print Name Date
SAVE PRINT
REV2.2020 Page 3 of 3
��,...
Drawing for Job#: Address ) / j G NST
1s°ia r
Customer U New WatarPlping. -----New Gas Pip!ng New Tankl..WWI- O OIdTanklacadon
Modelk �
Water Heater BTU's �(���
Total Feet of Gas Line `, �
Outdoor Dist to Property Line — \e
Residential Gas
' Water Professional Classic
Atmospheric Water Heaters
The new degree of comfort'
Professional Classic°Atmospheric gas
water heaters are engineered for more
hot water at a low operating cost L `'
Efficiency Altitude Certification
• .58- .66 UEF •All models certified up to 5,999 feet
• More hot water at a low operating cost above sea level, some certified up
to 10,000 feet. Consult factory for
Performance specifications
• FHR: 51 -87 gallons Plus...
rz
• Recovery:30.3 to 40.4 GPH at a IVA e
Easy to light—no matches required
90'F rise, depending on model . EverKleen®patented system fights
Guardian System'"&Sensor sediment build-up
• Exclusive air/fuel shut-off device • Exclusive Rheemglas®tank lining
• Maintenance free—no filter to clean resists corrosion and prolongs tank life
• Protective control system that • Enhanced flow brass drain valve
disables the heater in the presence of •Temperature and pressure relief valve
flammable vapor accumulation included
• Factory installed temperature and
pressure relief valve on select models
• Low lead compliant
Combustion Shut-off System .'Flame Arrestor Plate •Standard replacement parts
Warranty
o •6-Year limited tank and parts
warranty"
Maintenance Free •With ProtectionPlusO the 6-year limited
tank warranty becomes 10-year Professional Classic
Low Emissions `See Residential Warranty Certificate for Atmospheric
• Eco-friendly burner, low NOx design complete information 29, 30, 40 and
• Meets 40 ng/J NOx requirements Units meet or exceed ANSI requirements and have 50-Gallon Capacities
been tested according to D.O.E.procedures.Units U to 40 000 BTU/h
Longer Life meet or exceed the energy efficiency requirements p
• Premium ro anod
e de d provides of NAECA,ASHRAE standard 90,ICC Code and all Natural and LP Gas
g long-lasting tank protection state energy efficiency performance criteria.
*LEED Point=1
See specifications chart on back.
INTEGRATED HOME
06/22 FORM NO.FROG RH N COMBO Rev.5
Residential Gas
' Water Professional Classic
Atmospheric Water Heaters
The new degree of comfort°
Professional Classic° Atmospheric Specifications
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS(SHOWN IN INCHES) ENERGY INFO.
GASINPUT RECOVERY FIRST
IN THOUS. IN G.P.H. HOUR HT.TO
T RATING HEIGHT HT.TO WATER SIDE WATER UNIFORM
Y NOMINAL RATED BTU/H 90°PRISE (GALLONS) TO TANK GAS VENT CONN. T&P CONN. SHIP ENERGY
P GALLON GALLON MODEL VENT HEIGHT DIAM. CONN. SIZE CENTER VALVE SIZE WE FACTOR
E CAPACITY CAPACITY NUMBER NAT. LP NAT. LP NAT. LP A B C D E F G H (LBS) (UEF)
Tall 29 28 PROG29-32N RH63 32 - 32.3 - 63 - 59-3/4 56-7/8 16-1/2 14-1/4 3 or 4 8 50-3/4 3/4 110 0.60
Tall 29 28 PROG29-30P RH63 - 30 - 30.3 - 63 59-3/4 56-7/8 16-1/2 14-1/4 3 or 4 8 50-3/4 3/4 110 0.60
Tall 40 38 PROG40-36NRH62t 36 - 36.4 - 64 - 61-1/2 58-1/2 19 14-1/4 3or4 8 52-1/4 3/4 127 0.58
Tall 40 38 PROG40-38NRH62t 38 - 38.4 - 64 - 61-1/2 58-1/2 19 14-1/4 3or4 8 52-1/4 3/4 127 0.58
Tall 40 38 PROG40-40NRH62t 40 - 40.4 - 84 - 63-1/4 60 19-1/2 14 3or4 8 53-1/2 3/4 135 0.66
Tall 40 38 PROG40-36PRH62t - 36 - 36.3 - 84 63-1/4 60 19-1/2 14 3or4 8 53-1/2 3/4 135 0.66
Tall 40 38 PROG40-32P RH62i - 32 - 32.3 - 67 61-1/2 58-1/2 18-1/2 14-1/4 3 or4 8 52-1/4 3/4 125 0.59
Tall 50 48 PROG50-40NRH62t 40 - 40.4 - 76 - 62-1/2 59-1/4 21-1/2 14-1/2 3or4 8 52-1/2 3/4 165 0.65
Tall 50 48 PROG50-36PRH621 - 36 - 36.4 - 76 62-1/2 59-1/4 21-1/2 14-1/2 3or4 8 52-1/2 3/4 165 0.65
Tall 50 48 PROG50-38NRH60t 38 - 38.4 - 85 - 61-1/4 58-3/8 20-1/2 14-1/4 3or4 8 51-3/8 3/4 150 0.64
Tall 50 48 PROG50-36PRH60t - 36 - 36.4 - 85 61-1/4 58-3/8 20-1/2 14-1/4 3or4 8 51-3/8 3/4 150 0.64
Short 30 29 PROG30S-301N RH63 30 - 30.3 - 51 - 49-7/8 47 19-3/4 14-1/4 3 or4 8 40-3/8 3/4 112 0.60
Short 40 38 PROG40S-40N RH62i 40 - 40.4 - 66 - 53-7/8 50-1/2 23 14-1/2 3 8 44 3/4 135 0.58
Short 40 38 PROG40S-36P RH62i - 36 - 36.4 - 66 53-7/8 50-1/2 23 14-1/2 3 8 44 3/4 135 0.58
Short 40 39 PROG40S-38NRH62t 38 - 38.4 - 65 - 53-1/4 50-1/4 21-3/8 14-1/4 3or4 8 44 3/4 125 0.58
Short 40 39 PROG40S-35PRH621 - 35 - 35.4 - 65 53-1/4 50-1/4 21-3/8 14-1/4 3or4 8 44 3/4 125 0.58
Short 40 38 PROG40S-34N RH62 34 - 34.3 - 65 - 52-3/8 49-1/8 21 14 3 or4 8 42-3/4 3/4 120 0.59
Short 40 38 PROG40S-31P RH62 - 31 - 31.3 - 65 52-3/8 49-1/8 21 14 3 or4 8 42-3/4 3/4 120 0.59
Short 50 48 PROG50S-40NRH61t 40 - 40.4 - 87 - 54-1/4 51-1/8 23-3/4 14-1/4 3or4 8 44 3/4 186 0.63
Short 1 50 1 48 1 PROG50S-36PRH61t - 36 - 36.4 - 87 54-1/4 51-1/8 23-3/4 14-1/4 3or4 8 44 3/4 186 0.63
Models with Installed Top T&P Valve
Tall 40 38 PROG40-38N RH62TT 38 1 - 138.41 - 1 64 1 - 1 61-1/2 58-1/2 19 14-1/41 3 or4 1 8 - 1 3/4 127 0.58
Tall 40 38 PROG40-40NRH62TT 40 - 40.4 - 84 - 63-1/4 60 19-1/2 14 3or4 8 - 3/4 135 0.66
Tall 50 48 PROG50-40NRH62TF 40 - 40.4 - 76 - 62-1/2 59-1/4 21-1/2 14-1/2 3or4 8 - 3/4 165 0.65
Tall 50 48 PROG50-38NRH60TT 38 - 38.4 - 85 - 61-1/4 58-3/8 20-1/2 14-1/4 3or4 8 - 3/4 150 0.64
Uniform Energy Factor and rated gallon capacity based on Department of Energy(DOE)requirements.
isFLUE O ANODEROD FLUE O ANODEROD
iLEED Point H COLD HOT H
WATER HOT WATER COLD
CONNECTION WATER
CONNECTION CON ECTION ; WATER
CONNECTION
INSTALLED
F T&P VALVE F
ICI EI�I it Eli
�T TOP"A 3R N.P.T.
-_ 1-1/2"ABOVE i i RELIEF
TOP PAN TO VALVE
CENTER OF OPENING
OPENING 0
C C�
A B A B
1/2" 1/2" G
f f
D D
Top T&P models
In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice.
Rheem Water Heating • 1115 Northmeadow Parkway,Suite 100
Roswell,Georgia 30076 • www.rheem.com
INTEGRATED HOME COMFORT
06/22 FORM NO.FROG RH N COMBO Rev.5