Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
870 Wesley St Unit 103_BLD5646_2025
i Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 591h Avenue NE • Arlington,WA 98223 • Phone (360)403-3551 Permit Number: BLD5646 Permit Type: Residential Plumbing Address/Parcel: 870 Wesley St Unit 103 Completed (Month/Year): EXPIRED April 2024 Land Use ❑ Notice of Decision ❑ Bonding or Assignment of Funds ❑ Staff Report o Confidential Documents. Contact the ❑ Application City to obtain. ❑ Narrative ❑ Letters and Project Documents ❑ Legal Description ❑ Other: ❑ Vicinity Map ❑ Site Plan Civil ❑ Landscape Plan ❑ Issued Permit ❑ Complete Streets Checklist ❑ Application ❑ Traffic Impact Analysis ❑ Other Applications ❑ Snohomish County Traffic Mitigation Offer ❑ Construction Calculation Worksheet ❑ WSDOT Traffic Offer Form ❑ Approved Plans ❑ Tree Survey ❑ Review Comment Form ❑ Stormwater Drainage Report ❑ Letters and Project Documents ❑ Geotech Report ❑ Other Agency Permits ❑ Critical Area Evaluation Form ❑ Reports: ❑ SEPA Checklist o Drainage Report Pg: ❑ Public Notice Material o Stormwater Pg: ❑ Noticing and Related Documents o Geotech Pg: ❑ Water/Sewer Availability Certificate o All Other Reports ❑ Unanticipated Discovery Plan Form ❑ SEPA and Noticing Materials ❑ Aerial Photo of Site ❑ Inspections ❑ Proposed Building Materials ❑ As-Builts ❑ Lighting Plans and Lighting Cut Sheets ❑ Other: ❑ Color Elevations ❑ Design Matrix Building ❑ Plat Map ❑✓ Issued Permit ❑ Title Report ❑✓ Application ❑ Lot Closures ❑ Additional Applications ❑ Preliminary Civil Plans ❑ Approved Plans ❑ Archaeological Survey ❑ Site Plan o Confidential Documents. Contact the ❑ Letters and Project Documents City to obtain. ❑ Calculations ❑ Topography(Existing Conditions) ❑✓ Project Specification Manuals ❑ CC&R's ❑ Reports ❑ Deeds/Easements/Conveyances ❑ Certificate of Occupancy /Dedications ❑ Inspections ❑ Developer's Agreement ❑ Other: ❑ Recorded Copies Page 1 of 1 ' CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center:360403-3551 BUILDING PERMIT 870 WESLEY ST UNIT 103 Permit#:5646 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 00878000010300 DATE OF ISSUANCE. Scope of Work: Replace 40 gallon natural gas water heater Valuation: 2448.32 OWNER APPLICANT CONTRACTOR GASS JULIE MICHELLE JO Absolute Plumbing Inc Absolute Plumbing 870 WESLEY ST UNIT 103 PO Box 1445 PO Box 1445 ARLINGTON,WA 98223-1682 Mount Vernon Mount Vernon,WA 98273 3606106141 360-610-6141 LIC:ABSOLP'799MB EXP:07/12/2024 LIC:603 305 333 EXP:05/31/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL PLUMBING CODE YEAR: 2018 STORIES: 1 CONST.TYPE: VB DWELLING UNITS: OCC GROUP: R-3; Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 10/IRCI 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. ` /O /& g 0g :?--;- Gi.� 10/13/2023 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved mechanical equipment.Call for final inspection.Permit shall be onsite for inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/13/2023 Processing/Technology $25.00 10/13/2023 Inspection $75.00 10/13/2023 Plumbing Base $25.00 10/13/2023 Water Heater(Tank) $25.00 10/13/2023 Medical Gas Piping $60.00 Total Due: $210.00 Total Payment: $210.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail RESIDENTIAL PLUMBING APPLICATION Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new,repaired,altered or replaced plumbing installation for existing residences. Please fill out all pages of this application and include all information. The City of Arlington does not require a permit to stop leaks or clear stoppages,unless the piping is repaired,altered or replaced. Type of Permit: ❑ New Installation ❑ Addition ❑ Alteration ❑ Repair Property Address: 870 Wesley St #1`-103 Project Valuation: 2448.32 Lot#: 12 Parcel ID No.: 00878000010300 Preferred Contact: ❑ Owner O Contractor Project Description:Replace 40 gallon natural gas water heater Owner Name: Brigitte Patterson Home No.: 206 454-9984 Email Address: Cell No.: Mailing Address: 870 Wesley St# 103 City: Arlington State: WA Zip:98223 Contractor Name: JO Absolute Plumbing Inc Office No.: 3606106141 Email Address: absoluteplumbing247@yahoo.com Cell No.: Mailing Address: PO BOX 1445 City: Mount Vernon State: WA Zip:98273 L&I Contractor License Number:ABSOLP*799MB Expiration Date: 05/31/2024 • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) • Cross-Connection-Control may be required Proposed Interior Water Piping Size: ❑ 1/" ❑ S/s" ❑ 3/4 ❑ 1" Proposed Interior Piping Material: ❑CPVC ❑ Brass ❑ Copper ❑ PEX-AL-PEX ❑ PEX ❑ Galvanized Steel ❑ Other Proposed Exterior Water Piping Size: ❑ 1/2" ❑ S/s" ❑ 3K" ❑ 1" ❑ 11/2" ❑ 2" Proposed Exterior Piping Material: ❑ PVC ❑ PE ❑ Copper ❑ PEX-AL-PEX ❑ PEX-AL-PE ❑ PEX ❑ Other Proposed Drain-Waste-Vent(DWV) ❑ Schedule 40 ABS DWV ❑ Copper ❑ Galvanized Steel ❑ Cast Iron Material: ❑ Schedule 40 PVC DWV ❑ Brass ❑ Other Proposed Drain-Waste-Vent(DWV) ❑ 1/„ ❑ s/s„ ❑ 3/a" ❑ 1" ❑ 11/2" ❑ 2" ❑ 3" 04" Piping Size: PLUMBING PERMIT FEES (per fixture) Type of Fixture No.of Fixtures Cost per Fixture Subtotal Additional Plan Review fees x $75.00 = Alteration repair piping x $ 15.00 = Backflow Assembly x $25.00 = Base Plumbing Fee 1 x $25.00 = $25.00 Bath Shower Combo x $ 15.00 = Building Main Waste x $25.00 = Clothes Washer x $ 15.00 = Dishwasher x $ 15.00 = REV03.2022 Pagel of 2 PLUMBING PERMIT FEES (per fixture) Drinking Fountain x $ 15.00 = Floor Drains x $15.00 = Grease Interceptor x $75.00 = Grease Trap x $25.00 = Hose Bibb x $15.00 = Icemaker Refrigerator x $ 15.00 = Irrigation-per meter x $25.00 = Kitchen Sink&Disposal x $ 15.00 = Laundry Tray x $ 15.00 = Lavatory x $ 15.00 = Med Gas Piping<-5 inlets outlets x $60.00 = Med Gas Piping> 5 inlets/outlets(plus<-5 x $5.00 = inlets outlets Miscellaneous-regulated by plumbing code,not x $ 15.00 = otherwise specified Pretreatment Interceptor x $15.00 = Re-inspection Fee x $75.00 = Roof Drains x $ 15.00 = Shower(only) x $ 15.00 = Sink bar,service,etc. x $ 15.00 = Toilets x $15.00 = Urinal x $ 15.00 = Vacuum Breakers x $25.00 = Water Heater 1 x $25.00 = MODEL NO.: X640T06RV36U1 Water Heater-Tankless x $25.00 = MODEL NO.: Permit Fee 25 Inspection Fee $75.00 Processing/Technology Fee $25.00 Total 125.00 I hereby certify that I am the❑Owner, EjApplicant, E Contractor,and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington,and the City of Arlington.A final inspection and approval shall be obtained when complete. ,Janine Hill 10/13/23 Sigr4atu e Print Name Date SAVE PRINT REV03.2022 Page 2 of 2 PERFORMANCE TM 00 The new degree of comfort' The PERFORMANCE TMatmospheric gas water heaters feature a diagnostic ' gas valve and a six-year warranty Efficiency Longer Life ■.59- .65 UEF I Premium grade anode rod provides Performance long-lasting tank protection ■FHR: 52-94 gallons Plus... ■Recovery: Up to 51 GPH at a ■Easy to light—no matches required 900 F rise, depending on model ■Temperature and pressure relief valve Diagnostic Valve included Self powered diagnostic ■Low lead compliant gas control valve for ■Standard replacement parts improved monitoring Warranty and service ■6-Year limited warranty for tank Low Emissions and parts, 1-year full in-home labor ■Eco-friendly burner, low NOx design warranty* ■Meets 40 ng/J NOx requirements 'See written warranty for complete details oa9nost Units meet or exceed ANSI requirements and have Maintenance Free been tested according to D.O.E.procedures.Units '• Burner System meet or exceed the energy efficiency requirements of NAener AS efficiency standard an I criteria. Code and all I ■Exclusive air/fuel shut-off device state energy efficiency performance criteria. ■Maintenance free—no filter to clean ■Disables the heater in the presence of flammable vapor accumulation PERFORMANCE 7i" M Atmospheric Combustion Shut-off System Flame Arrestor Plate 29, 30, 40, 50 and 55-Gallon Capacities Up to 50,000 Btu/h Maintenance Free © LP iLEED Point=1 See specifications chart on back. 04/17 FORM NO.THD-PGRH N Rev.3 The new degree of comfort- PERFORMANCE- Atmospheric Gas Specifications Ht.to Water Water 7Energy niform Inal R Gas I ut Recovery First Hour Ht.to Tank Gas Vent Conn. Ht.to Side Conn. Shipnergy Gallon Gallon Model in Thous. in G.P.H. Delivery Vent Height Diam. Conn. Size Center T&P Valve Size Weight actor Description Capacity Capacity Number Btu/h 90°F Rise G.P.H. A B CD E F G H (LBS) (UEF) , i i Tall 55 55 XG55T ECEC5000I 50 51 94 59-1/8 55-7/8 23-3/4 14-1/4 4 8 48-3/4 3/4 175 0.59 0.62 Tall 55 55 XP55TO6EC451.10r 45 46 94 59-1/8 55-7/8 23-3/4 14-1/4 4 8 48-3/4 3/4 175 0.59 0.62 DiagnosticPerformance-Self Powered Tall 50 48 XG50T06HE4000} 40 40.4 83 62-3/4 59-1/4 21-1/2 14-1/2 3 or4 8 52-1/2 3/4 165 0.62 0.65 Short 40 39 XG40SME381.101 38 38.4 67 53-3/4 50-1/4 21-1/2 14-1/2 3 8 44 3/4 125 0.62 0.59 Tall 50 48 XP50TO6HE36UOt 36 36.4 81 62-3/4 59-1/4 21-1/2 14-1/2 3 or4 8 52-1/2 3/4 165 0.62 0.65 Short 40 39 XP4OSO6HE36UOt 36 36.4 67 53-3/4 50-1/4 21-1/2 14-1/2 3 8 44 3/4 125 0.62 0.59 Tall 50 48 XG50T06EC38U1 38 38.4 78 61-1/4 58-1/4 20-1/2 14-1/4 3or4 8 51-3/8 3/4 140 0.60 0.63 Short 50 48 XG50S06EC40U1 40 40.4 80 54-1/4 51 23-3/4 14-1/4 3or4 8 44 3/4 186 0.60 0.64 Tall 40 38 XG40T06EC36U1 36 36.4 67 61-1/2 58-1/2 19 14-1/4 3or4 8 52-1/4 3/4 127 0.62 0.59 Short 40 39 X140SO6E134UO 34 34.3 67 52-1/8 49-1/4 21 14-1/4 3or4 8 42-3/4 3/4 120 0.62 0.59 Short 30 29 XG30S06EC30U1 30 30.3 52 49-7/8 46-1/4 19-3/4 14-1/4 3or4 8 40-3/8 3/4 112 0.63 0.60 Tall 29 28 XG29T06EC32U1 32 32.3 50 59-3/4 56-1/2 16-1/2 14-1/4 3or4 8 50-3/4 3/4 110 0.63 0.60 ��. Tall 50 48 XP50TO6EC36Ul 36 36.4 92 61-1/4 58-1/4 20-1/2 14-1/4 3or4 8 51-3/8 3/4 125 0.60 0.63 Tall 40 38 XP40T06EC32U1 32 32.3 67 61-1/2 58-1/2 18-1/2 14-1/4 3or4 8 52-1/4 3/4 125 0.62 0.59 Tall 29 28 XP29T06EC30U1 30 30.3 52 59-3/4 56-1/2 16-1/2 14-1/4 3or4 8 50-3/4 3/4 110 0.63 0.60 Uniform Energy Factor,Energy Factor and rated gallon capacity based on Department of Energy(DOE)requirements. G. FLUE O ANODE ROD tLEED PoiM=1 H HOT O O COLD H WATER i i CONNECTION WATER CONNECTION ' F 'i i it E If 3/4" N.P.T. RELIEF VALVE OPENING 0 C A B 1/2" G D In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road Montgomery,Alabama 36117-4305 • www.rheem.com 04/17 FORM NO.THD-PGRH N Rev.3