Loading...
HomeMy WebLinkAbout4804 196th Pl Ne_BLD5631_2025 i Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 591h Avenue NE • Arlington,WA 98223 • Phone (360)403-3551 Permit Number: BLD5631 Permit Type: Residential Mechanical Address/Parcel: 4804 196th PI Ne Completed (Month/Year): October 2023 Land Use ❑ Notice of Decision ❑ Bonding or Assignment of Funds ❑ Staff Report o Confidential Documents. Contact the ❑ Application City to obtain. ❑ Narrative ❑ Letters and Project Documents ❑ Legal Description ❑ Other: ❑ Vicinity Map ❑ Site Plan Civil ❑ Landscape Plan ❑ Issued Permit ❑ Complete Streets Checklist ❑ Application ❑ Traffic Impact Analysis ❑ Other Applications ❑ Snohomish County Traffic Mitigation Offer ❑ Construction Calculation Worksheet ❑ WSDOT Traffic Offer Form ❑ Approved Plans ❑ Tree Survey ❑ Review Comment Form ❑ Stormwater Drainage Report ❑ Letters and Project Documents ❑ Geotech Report ❑ Other Agency Permits ❑ Critical Area Evaluation Form ❑ Reports: ❑ SEPA Checklist o Drainage Report Pg: ❑ Public Notice Material o Stormwater Pg: ❑ Noticing and Related Documents o Geotech Pg: ❑ Water/Sewer Availability Certificate o All Other Reports ❑ Unanticipated Discovery Plan Form ❑ SEPA and Noticing Materials ❑ Aerial Photo of Site ❑ Inspections ❑ Proposed Building Materials ❑ As-Builts ❑ Lighting Plans and Lighting Cut Sheets ❑ Other: ❑ Color Elevations ❑ Design Matrix Building ❑ Plat Map ❑✓ Issued Permit ❑ Title Report ❑✓ Application ❑ Lot Closures ❑ Additional Applications ❑ Preliminary Civil Plans ❑ Approved Plans ❑ Archaeological Survey ❑ Site Plan o Confidential Documents. Contact the ❑ Letters and Project Documents City to obtain. ❑ Calculations ❑ Topography(Existing Conditions) ❑✓ Project Specification Manuals ❑ CC&R's ❑ Reports ❑ Deeds/Easements/Conveyances ❑ Certificate of Occupancy /Dedications ❑ Inspections ❑ Developer's Agreement ❑ Other: ❑ Recorded Copies Page 1 of 1 CITY OF ARLINGTON • 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 4804 196TH PL NE Permit#: 5631 PERMIT EXPIRES 180 DAYS AFTER Parcel#:00671900000200 DATE OF ISSUANCE. Scope of Work:Replace existing electric furnace with a new electric furnace. Valuation:6883.00 OWNER APPLICANT CONTRACTOR BANC ONE MTG CORP Day and Nite Plumbing and Heating Day&Nite Plumbing&Heating,Inc ROBERTSON JOANNE H 8928467 450 16614 13th Ave W 16614 13th Ave W E WASHINGTON ST#324 INDIANAPOLIS,WA 46204 Lynnwood,WA 98037 Lynnwood,WA 98037 425-775-6464 425-775-6464 LIC:DAYNINP789D5 EXP:03/29/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2018 STORIES: 1 CONST,TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC I I OARC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. �a �1�LGy. 10/10/2023 --h d Applicant Signatu /batJ Building Official Date CONDITIONS Adhere to approved plans.Call for inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/10/2023 Processingfrechnology $25.00 10/10/2023 Inspection $75.00 10/10/2023 Mechanical Base $25.00 10/10/2023 Forced Air Heat $15.00 10/10/2023 Credit Card Service $3.75 10/10/2023 Credit Card Service $0.45 Total Due: $144.20 Total Payment: $144.20 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/fail RESIDENTIAL MECHANICAL APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit: ❑ New Installation ❑✓ Addition/Alteration/Repair ❑ Gas Piping Property Address: 4804 196th PI NE Project Valuation: 6,883.00 Lot#: Parcel ID No.: 00671900000200 Preferred Contact: ❑ Owner ❑ Contractor Project Description: Replace existing electric furnace with a new electric furnace. Owner Name: Amine Nhila Home No.: hil ana . 217-417-8371 Email Address: @gmailcom Cell No.: Mailing Address: 4804 196th PI NE City: Arlington State: WA Zip:98223 Da and Nite Plumbing and Heating 425-775-6464 Contractor Name: Y 9 9 Office No.: Email Address: bryan@dayandnite.net Cell No.: Mailing Address: 16614 13th Ave W City: Lynnwood State: WA Zip:98037 L&I Contractor License Number: DAYNINP789D5 Expiration Date: 3/29/24 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information O Not Applicable ❑ CSST ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ 1/2" ❑ 5/s" ❑ 3/4" ❑ 1" ❑ 11/2" ❑ 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: MECHANICAL PERMIT FEES (per unit) Type of Fixture No.of Units Cost per Unit Subtotal Model No. Additional Plan Review fees x $75.00 = Air Cond.Unit 5100Btu h x $ 15.00 = Air Cond.Unit>100Btu h x $25.00 = Air Cond.Unit>500Btu h x $50.00 = Air Handling Units 1 x $15.00 = 15.00 Base Mechanical Fee 1 x $25.00 = $2S.00 Boiler<100Btu h>3hp x $ 15.00 = Boiler>1 million Btu/h<SOhp x $25.00 = REV03.2022 Pagel of 2 MECHANICAL PERMS FEES (per unit) Boiler>1.5 million Btu/h<50hp x $50.00 = Boiler>100Btu h 3-15h x $15.00 = Boiler>500Btu h 1S-30hp x $25.00 = Commercial Hoods-Type I x $25.00 = Commercial Hoods-Type II x $50.00 = Diffusers x $15.00 = Dryer Ducting x $15.00 = Ductwork(drawings required) x $25.00 = Evaporative Coolers x $15.00 = Exhaust Ventilation Fans x $15.00 = Fireplace/Insert/Stove x $15.00 = Forced Air Heat<_100 Btu h x $15.00 = Forced Air Heat>100 Btu h x $25.00 = Gas Clothes Dryer x $15.00 = Gas Fired AC 5100 Btu h x $15.00 = Gas Fired AC>100 Btu h x $25.00 = Gas Fired AC>500 Btu h x $50.00 = Gas Pi in 5 5 units x $15.00 = Gas Piping>5 units (plus<5 units x $2.00 = Heat Exchangers x $15.00 = Heat Pump-Condensing Unit x $25.00 = Hot Water Heat Coils x $15.00 = Miscellaneous Appliance-regulated by x $15.00 = mechanical code,not otherwise specified Pkg.Units 5100btu x $25.00 = Pkg.Units>100btu x $50.00 = Range/Cook top-Gas Fired x $15.00 = Refrigeration Unit_<100Btu h x $15.00 = Refrigeration Unit>100Btu h x $25.00 = Refrigeration.Unit>500Btu h x $50.00 = Re-inspection fee x $75.00 = Residential Range Hood x $15.00 = Unit Heaters 5 100 Btu h x $15.00 = Unit Heaters>100 Btu h x $25.00 = VAV Boxes(Variable Air Volume,part of air x $10.00 = conditioning system) Wall Heaters-Gas Fired x $25.00 = Water Heater-Gas Fired x $25.00 = Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total REV2.2020 Page 2 of 2 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated 1 hereby certify that 1 am the ❑Owner, ❑Applicant, ❑Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be it)accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington.A final inspection and approval shall be obtained when complete. 41�t_ Bryan Radcliff 10/9/23 Signa e Print Name Date SAVE PRINT REV2.2020 Page 3 of 3 " 1COIL SIZES 002 THRU II . 1hroduct Data PREMIUM ENVIRONMENTALLY SOUND FAN COIL The FV4C is the premium air handler combining the proven technology of Bryant fan coils with environmentally sound Puron© l` refrigerant.The FV4C achieves an operational advantage when the ECM (Electronically Commutated Motor) is combined with a Bryant Preferred' heat pump with Puron®refrigerant. With attention to quiet,efficient,and comfortable operation,Bryant has developed a new benchmark for superior indoor comfort and ++++J control. Bryant's heat pump and air conditioning systems now feature Puron© refrigerant(R-410A), the chlorine-free refrigerant that is the future for the residential heating and cooling industry. The FV4C using Puron© refrigerant maximizes performance for environmentally sound systems. In addition to environmental safety, these systems are 30 to 40% more efficient than standard heating and cooling systems, thereby combining excellence in efficiency and environmental safety. The FV4C provides these benefits due to Bryant's command of ECM technology. These motors are extremely efficient at all 1 speeds, and enable the FV4C to operate at the correct speed to deliver airflow precisely, ensuring proper performance across a wide range of duct static pressures. This adaptive efficiency also makes installation quality easier to achieve for today's demanding homeowner. Bryant's command of ECM technology may be most evident in the comfort advantages that ECM can deliver. Operation set up steps on the Easy Select' Board provide the installing technician with alternatives to maximize comfort and efficiency. For true indoor comfort, the homeowner can achieve command of both temperature and humidity in cooling and heating modes. Another feature which sets the FV4C apart is the factory-installed TXV, which enhances efficiency and provides compressor protecting operation at all recommended conditions. Grooved tubing, louvered aluminum fins, and the large face areas of the FV4C refrigerant coils also provide superior efficiency, for high SEER and HSPF performance.Bryant leads the way in condensate control, a hallmark of these multipoise fan coils. All of these featured components are protected within a rugged, prepainted i• metal cabinet lined with super thick, high density insulation. For neat, high quality installations the unit exterior features sweat refrigerant connections for simple leak free performance, and multiple electrical entry for both high and low voltage service. .' For superior technology and unmatched comfort, the environmentally sound and efficient FV4C can't be beat. A/ l� ��-o�1&Cl-+ � �5 FEATURES Environmentally Sound Refrigerant Technology • Puron®,chlorine-free,non-ozone depleting refrigerant • Thermostatic Expansion Valve(TXV)designed to maximize performance with Puron®refrigerant Energy Efficient Operation • Electronically Commutating Motor(ECM)operates efficiently at all speeds • Maximizes efficiency of heating and cooling systems • Ultra low power consumption during fan only operation Indoor Weather Control • Warm,comfortable heating air temperatures • Unmatched humidity control,especially with Bryant's thermostats with relative humidity controls Airflow and Sound Technology • Diffuser air discharge section for high airflow efficiency and quiet,smooth operation • High duct static capability • Unique cabinet design that meets new stringent regulations for air leakage.Meets requirements of a 2%cabinet leakage rate when tested at 1.0 inches of static pressure Condensate Control and Disposal Technology • Minimal standing waterless microbial growth for improved IAQ and reduced condensate line clogging and related condensate leakage • Condensate fittings relocated away from turbulent airflow patterns at the blower entrance for improved condensate control performance • Overflow feature for slope coil units allows condensate to exit the unit without damage to product under clogged primary and secondary line conditions • Tested for condensate disposal at conditions much more severe than those required by AHRI • Primary and secondary drain connections to comply with HUD • All pans constructed of an injection molded glass-filled polycarbonate engineered resin material,with brass drain connections. • High density,super thick cabinetry insulation with vapor barrier • Pre-painted galvanized sheet metal cabinet Heat Transfer Technology • Grooved tubing • Lanced sine wave aluminum fins • Discreet refined counter-flow refrigerant circuitry • Bi-flow hard shut-off TXV metering device Quality Assisting,Ease of Installation and Service Features • All units multipoise • Provision made for suspending from roof or ceiling joints • Modular cabinet on 003 thru 006 units • Sweat connections for leak free service • Multiple electrical entry for application flexibility(high and low voltage) • Low voltage terminal strip,to safely hold connections within the cabinet • Cabinet construction features innovations designed to prevent cabinet sweating Controls and Electrical Features • Easy Select- Board to maximize comfort,efficiency,and safe heater airflow operation • Easy plug connection provided for quick installation of accessory heater packages • 40VA 208/230v transformer • Replaceable 5-amp blade-type auto fuse protects against transformer secondary short Filter Features • Factory supplied filter • Cleanable polyester filter media • Filter"springs"out for easy access-no tools required • Newly improved filter rack area-filter door insulation added for an improved air seal 2 MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 F V 4 C N B 0 0 3 0 0 0 Product F=Fan Coil Type V=Puron© Refrigerant Coil Type Position T00=Tin—plated 4=Multipoise 000=Copper L00=Aluminum Series C Capacity 002=18-36,000 Electrical 003=24-42,000 N =208/230v,1 ph-60 Hz 005=30-48,000 006=30-60,000 Cabinet/Insulation B=Modular F=Single piece ® Use of the d l Cergfied p�pa Inelcatese O �� Puron.,. ram For e bon In Vie 0 ogrem Forveri nid , M.—aimeniary wino rehgaam 1 cergficatbn for iMivitlual pructs,go to ehricli-t.y«g. ISO 9001 wli Gi In, , • rm A SPECIFICATIO COIL Refrigerant Metering Device uron®Refrigerant(R-410A) TXV Size 2 Ton 3 Ton 1 4 Ton 5 Ton Rows/Fins Per In. 3/14.5 Face Area(Sq Ft) 3.46 15.93 7.42 Configuration A Slope A BLOWER&MOTOR Air Discharge Upflow,Downflow,Horizontal 525/470 700/630 875/785 1050/945 CFM(Nominal Clg/Htg) 700/630 875/785 1050/945 1225/1100 875/785 1050/945 1225/1100 1400/1260 1050/945 1225/1100 1400/1260 1750/1575 Motor HP(ECM) 1/2 3/4 FILTER CLEANABLE 21-1/2"(546 mm)by 16-3/8"(417 mm)1 19-7/8"(505 mm) 23-5/16"(585 mm) CABINET CONFIGURATION OPTIONS 1 Piece 1 Piece or Modular Modular 3 E co co �=W =E o _ W E ro I I I aW Jed •_ __ � � I I I I -$t �`�'- I I I N N M g • E fl f- N co h LA E a a � N vm w I m I �o Y' D) D) N O m O (D CO CO N (D (D o�`V�� E oo ao N rn ao ao S6 Ws< E Itv (n co V -q Ig (0 OO m W M N (D a) D) N H E E D) co N O D) D) m m tO o m m E v v (n v v v nSlt a v d a a = I I CO C I I �oLL D) m N (n m D) N E r- r` r- cD N r- co co E Lo co Lo (co ND Lo Lo CC)Zm (D 0o m r — ao cD ` = I I — LO I I N r` n o� co v r` r-o m (n (n E M M � o M M mu Z7- o _ 0 - Cl)LO LO D) N Cl) M .� . - z S� O Lu M LO CON co N n - N O O O O 00 0 0 0 0 z N mLL 1 Z z z z z z Z V> d' V> UO' VU' V> A 4 ® F. YCCOo °r° rnmc00o °r° - © o C7 ED a_ O N r m O N �) T N M N r O O W N V Z— G 0 pW O O x- _ _ ~ a W W „ - n. Q_ pJ Q Q Q O Q :Xg ti 3� o S © �> b © Oj ~ S� p oo Ernrnrn � rn <r o) m N O O co E co (o co V' (o (o _ - d „ � I I I I I g oa O N N M M N (o Z.© - ?a b o o d N a E „ - ` OOO co � co - { o m F^ LL O 'd i i i rn i s .— -W= - =N c i i i I i � �''� - co (o N M co N p 4 IR- i V N N co N El. Ell M (n (o 0 0 Co) 0 0 M O M 0 0 0 Z Z Z Z Z Z vvvv � v A 5 PERFORMANCE DATA FV4C ADVANCED FAN COIL AIRFLOW DELIVERY CHART (CFM) OPERATING MODE SINGLE—SPEED TWO—SPEED APPLICATION FAN ONLY APPLICATION UNIT OUTDOOR High Speed Low Speed SIZE UNIT Nominal A/C Nominal A/C Nominal A/C CAPACITY A/C Cooling Lo Med High Cooling Dehumidity A/C Cooling A/C Cooling Cooling Dehumidity Cooling Dehumidity 018 525 420 — — — — 350 420 525 024 700 560 700 560 560 450 350 560 700 002 030 875 700 — — — — 440 700 875 036 1050 840 1050 840 840 670 525 840 1050 024 700 560 700 560 560 450 415 560 700 033030 875 700 — — — — 440 700 875 003 036 1050 840 1050 840 840 670 525 840 1050 042 1225 980 — — — — 610 980 1225 030 875 700 — — — — 440 700 875 036 1050 840 1050 840 840 670 525 840 1050 005 042 1225 980 — — — — 610 980 1225 048 1400 1120 1400 1120 1120 895 700 1 1120 1400 036 1050 840 1050 840 840 670 540 840 1050 042 1225 980 — — — — 610 980 1225 006 048 1400 1120 1400 1120 1120 895 700 1120 1400 060 1750 1400 1750 1400 1400 1120 875 1400 1750 NOTES: 1. The above airflows result with the AC,HP CFM ADJUST select jumper set on NOM. 2. Air flow can be adjusted+15%or—10%by selecting HI or LO respectively for all modes except fan only. 3. Dry coil at 230 volts and with 10kW heater and filter installed. 4. Airflows shown are at standard air conditions. *Consult ARI ratings before matching outdoor unit with FV4C fan coil. FV4C ADVANCED FAN COIL AIRFLOW DELIVERY CHART (CFM) OPERATING MODE SINGLE—SPEED TWO—SPEED APPLICATION FAN ONLY OUTDOOR APPLICATION UNIT UNIT High Speed Low Speed SIZE CAPACITY Heat Pump Heat Pump Comfort Efficiency Heat Pump Heat Pump Heat Pump Heat Pump Lo Med High Comfort Efficiency Comfort Efficiency 018 470 525 — — — — 350 380 470 024 630 700 630 700 505 560 350 505 630 002 030 785 875 390 630 785 036 945 1050 945 1050 755 840 470 755 945 024 630 700 630 700 415 560 415 505 630 00003003 030 785 875 — — — — 415 630 785 036 945 1050 945 1050 755 840 470 755 945 042 1100 1225 — 550 880 1100 030 785 875 — — — — 425 630 785 036 945 1050 945 1050 755 840 470 755 945 005 042 1100 1225 — — — — 550 880 1100 048 1260 1400 1260 1400 1010 1120 630 1010 1260 036 945 1050 945 1050 755 840 540 755 945 042 1100 1225 — — — — 550 880 1100 006 048 1260 1400 1260 1400 1010 1120 630 1010 1260 060 1575 1750 1575 1750 1260 1400 785 1260 1575 NOTES: 1. The above airflows result with the AC,HP CFM ADJUST select jumper set on NOM. 2. Air flow can be adjusted+15%or—10%by selecting HI or LO respectively for all modes except fan only. 3. Dry coil at 230 volts and with 10kW heater and filter installed. 4. Airflows shown are at standard air conditions. 6 PERFORMANCE DATA (cont) AIRFLOW DELIVERY CHART(CFM)—ELECTRIC HEATING MODES FAN OUTDOOR ELECTRIC HEATER kW RANGE UNIT UNIT 0-5 0-10 0-15 0-20 SIZE CAPACITY BTUH Lo Nom High Lo Nom High Lo Nom High Lo Nom High 18,000 625 625 625 675 675 — — — — — — — 24,000 650 725 835 — 725 835 875 875 875 — — — 002 30,000 815 905 1040 — 905 1040 900 900 1040 1100 1100 1100 36,000 980 1085 1250 980 1085 1250 980 1085 1250 1100 1100 1250 24,000 675 725 835 875 875 — — — — — — — 30,000 815 905 1040 875 905 1040 1100 1100 1100 — — — 003 36,000 980 1085 1250 980 1085 1250 1100 1100 1250 1225 1225 1250 42,000 1140 1270 1460 1140 1 1270 1 1460 1 1140 1270 1460 1225 1270 1460 FAN OUTDOOR ELECTRIC HEATER kW RANGE UNIT UNIT 0-10 0-15 0-20 0-30 SIZE CAPACITY BTUH Lo Nom High Lo Nom High Lo Nom High Lo Nam High 30,000 975 975 1040 1100 1100 1100 — — — — — — 36,000 980 1085 1250 1100 1100 1250 1250 1250 1250 — — — 005 42,000 1140 1270 1460 1140 1270 1460 1250 1270 1460 — — — 48,000 1305 1450 1665 1305 1450 1665 1305 1450 1665 1500 1500 1665 36,000 1100 1100 1250 1350 1350 1350 — — — — — — 42,000 1140 1270 1460 1350 1350 1460 1525 1525 1525 — — — 006 48,000 1305 1450 1665 1350 1450 1665 1525 1525 1665 1750 1750 1750 60,000 1630 1810 2085 1630 1810 2085 1630 1810 2085 1750 1810 2085 NOTE:Lo,NOM,and HI refer to AC,HP CFM ADJUST selection. — Airflow not recommended for heater/system size. MINIMUM CFM FOR ELECTRIC HEATER APPLICATION CFM FAN COIL UNIT HEAT PUMP HEATER SIZE kW UNIT SIZE 5 8,9,10 15 18,20 24,30 Heater Only 625 625 725 875 — 018 625 625 — — — 002 024 650 725 875 — — 030 800 875 875 1040 — 036 970 970 970 1040 — Heater Only 675 700 1650 1050 — 024 675 875 — — — 003 030 800 875 1100 — — 036 975 975 1100 1225 — 042 1125 1125 1125 1225 — Heater Only 675 700 1050 1050 1400 018 800 875 1100 — — 005 036 975 975 1100 1225 — 042 1125 1125 1125 1225 — 048 1305 1305 1305 1305 1400 Heater Only 1050 1050 1050 1050 1750 018 1100 1100 1350 1350 — 006 042 1125 1125 1350 1350 — 048 1300 1300 1350 1465 1750 060 1625 1625 1625 1750 1750 NOTES: 1. Heater Only—Air conditioner with electric heater application. 2. These airflows are minimum acceptable airflows as UL listed.Actual airflow,delivered will be per airflow delivery chart for Electric Heating Modes. 7 PERFORMANCE DATA (cont) 5.7 0.6 -------------4--------------1--------------I------------- --------------I------------- 0.5 ------------ ------------- --------------------------- ------------- ------------- ti 0.4 ------------------------- --------------------------- ---------------------------- ACCEPTABLE RANGE RETURNTOOHIGH STATIC 0.3 ------------—---------------------------------------- --- PRESSURE fA��LT TO MAKE i 0.2 -------------—-------------------------- ------------- ------------—------------ 0.1 ------------—----------------------------------------- --------------------------- 0 0 0.1 02 0:3 0A 0:5 0.6 RETURN STATIC PRESSURE,IN.W.C. A02296 ACCEPTABLE DUCT CONDITIONS For satisfactory operation(specifically making dry secondary trap), system static pressure drop at any airflow given the actual drop at 1 subject fan Coils must be installed with duct systems which fall known point. within the"Acceptable Range"illustrated above. For example, a duct system is designed for 0.15 in.water column The airflow performance charts for the FV4C fan coil depict (in. w.c.) drop at 1200 CFM. The FV4CNF005 operating at nominal airflow delivery for heating and cooling mode operation nominal cooling airflow would deliver 1050 CFM with a duct versus duct system static pressure drop.Cooling mode operation is system drop of 0.11 in. w.c.. (See point 1.) On the same duct shown as solid vertical lines for all 4 system size selections. system, the FV4CNF005 operating at nominal heating airflow Heating mode operation for the 4 system size selections are shown would deliver 945 CFM with a duct system drop of 0.09 in.w.c. as dashed vertical lines. (See point 2.) The dotted curved lines are static pressure drop characteristics for This example is but one of many possible duct system designs.The several fixed-duct systems.These lines can be used to predict the FV4CNF005 will deliver the above airflows against much higher static pressures. AIRFLOW PERFORMANCE NOM. CLG DUCT NOM SYSTEMS HTG cc to 1 2 L__036 i I 1 1 945 1050 mo SCFM A09339 8 AIRFLOW PERFORMANCE 0.9- 0.8— .4 0.7— d 0.6— w A LU X (L 0.5 I I I J* Z ac 0.2— .............. .......... f 0.1 ........ ................. .......... ............. ........................ . ............ 1 1 036 0118-0 to-024-v- 1-+-030 036— Hi Cooling 0 i 400 500 600 700 800 900 1000 1100 1200 1300 SUM A09340 FV4CNFOO2 Nominal Cooling and Heat Pump Efficiency airflow for each size selection.Airflow can be adjusted+15%to—10%. ———— Nominal Heat Pump Comfort airflow for each size selection.Airflow can be adjusted+15%to—10%. Maximum cooling airflow for largest size selection.Adjusted+15%from nominal. ...... Fixed Duct Systems(See description under Acceptable Duct Conditions.) 9 AIRFLOW PERFORMANCE 1.3- 1 1.2- 1 I I Y 1.0- It 1 It 1 I I 0.9- 0.8- Mill 0.7- CL F- -J 0.6- Z 0.5 0.4- 0.3- 0.2- .............. ............ .............................. L. ............... 0.1 .......... ............... - ............... 1 042. ............*** I --I I-o-024 1 1 030 036---m-1 :-*-042----J Hi Cooling 0 500 600 700 800 900 1000 1100 1200 1300 1400 1500 SUM A"9341 FV4CN B'F �03 �.J� Arfl.w can be ad '15.X Nominal Cooling and Heat Pump Effi airflow for each i cti.n to for ea ch a �ec + s, w c e a Ju,'to 15Z ---- Nominal Heat Pump Comfort airflow an to —- Maximum cooling airflow for largest size selection.Adjusted+15%from nominal. ...... Fixed Duct Systems(See description under Acceptable Duct Conditions.) 10 AIRFLOW PERFORMANCE 1.3- 1.2- 1.1 lAt I It 1.0- 0.9- 0.8- LLI UJ 0.7-' 0 1 rl -J 0.6- Z w 0.5- 0.4 0.3- 0.2- 0.1 ............ - ........... J...... ........... ........... ... ......... 048 030 ► 1-0360 1 042—P. 1,048, Hi Cooling 0 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 SUM A09342 FV4CN(B,F)005 Nominal Cooling and Heat Pump Efficiency airflow for each size selection.Airflow can be adjusted+15%to—10%. ———— Nominal Heat Pump Comfort airflow for each size selection,Airflow can be adjusted+15%to—10%. Maximum cooling airflow for largest size selection.Adjusted+15%from nominal. ...... Fixed Duct Systems(See description under Acceptable Duct Conditions.) 11 AIRFLOW PERFORMANCE 1.7- 1.6- 1.5- 1.4- 1.3- 1.2— it 1.0- 0.9— V) LU cc 0.8— 0. -J 0.7I 'I— /* <z UJ 0.6- 0.4— 0.3- 0.2— ... ........ ................. ........... ....... ..... ............................ ............... ............ ......... ........................... 0.1— ............J................. ............ ..... .................. .......... ..... 060 ..............:0-036--; 1,048­p- 060— Hi Cooling 0 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 SUM A09343 FV4CNBOO6 Nominal Cooling and Heat Pump Efficiency airflow for each size selection.Airflow can be adjusted+15%to—10%. ———— Nominal Heat Pump Comfort airflow for each size selection.Airflow can be adjusted+15%to—10%. Maximum cooling airflow for largest size selection.Adjusted+15%from nominal. ...... Fixed Duct Systems(See description under Acceptable Duct Conditions.) 12 PERFORMANCE DATA (cont) COOLING CAPACITIES (MBtuh) EVAP SATURATED TEMPERATURE LEAVING EVAPORATOR(°F/'C) UNIT COIL 35/2 1 40/4 1 45/7 7 50/10 1 55/13 SIZE AIR Evaporator Air-Entering Wet-Bulb Temperature Cfm 72°F 67°F 62°F 72°F 67°F 62°F 72°F 67°F 62°F 72°F 67°F 62°F 72°F 67°F 62°F BF 22°C 19°C 17°C 22°C 19°C 17°C 22°C 19°C 17°C 22°C 19°C 17°C 22°C 19°C 17°C 500 40 32 26 36 28 22 32 24 18 27 19 14 21 13 11 0.04 18 18 19 16 16 17 14 14 15 12 12 13 10 10 11 650 50 40 32 45 36 27 39 30 22 33 24 18 26 17 14 0.07 21 22 23 19 20 21 16 17 18 14 15 16 12 13 14 002 875 58 49 38 53 42 32 46 35 27 39 28 22 31 20 18 0.10 24 26 28 22 24 25 19 21 22 17 19 19 15 16 18 1000 62 51 41 56 45 35 50 38 29 42 30 24 33 22 20 0.11 26 28 31 23 26 28 21 23 25 18 20 21 16 18 20 1250 67 55 45 61 49 39 54 42 33 46 34 28 37 25 24 0.13 29 33 36 27 30 33 24 27 30 22 24 26 19 21 24 800r28 48 38 53 42 32 46 35 24 39 27 20 30 18 16 0.20 293125 27 28 22 23 24 19 20 20 16 16 16 1000 56 45 61 49 37 54 41 29 45 32 25 35 22 20 003 0.22 34 37 29 31 33 26 28 28 23 24 25 19 20 20 1200 62 49 68 54 42 60 45 34 50 36 29 40 25 23 0.25 39 42 32 36 38 29 32 33 26 28 29 22 23 23 1400 80 67 54 73 59 46 64 49 38 54 39 32 43 28 27 0.27 38 43 47 35 39 43 32 36 37 28 32 32 24 26 27 750 61 49 39 55 43 33 48 37 27 41 29 20 33 21 17 0.04 `27 27 28 24 25 25 181R6146 22 18 18 18 15 15 15 950 74 60 48 67 53 40 33 50 35 25 39 24 21 0.06 32 34 35 29 30 31 27 22 23 23 18 18 19 005 1150 89 72 57 79 63 48 38 58 41 31 44 29 25 0.07 37 39 41 33 35 36 32 25 26 27 20 22 22 1500 103 84 66 92 73 56 46 67 48 39 52 34 31 0.10 43 46 49 38 41 44 39 29 32 33 25 27 27 1700 110 89 71 99 78 60 49 72 51 42 56 37 35 0.11 45 50 53 41 45 48 42 31 34 36 27 29 30 1050 77 62 50 69 55 43 35 52 38 27 41 27 22 0.01 34 36 37 31 32 33 29 23 25 24 20 20 20 1300 100 82 65 90 71 55 79 60 45 66 47 37 49 32 27 0.02 42 45 47 37 40 42 33 35 37 29 31 32 23 25 24 006 1750 117 96 77 106 84 65 93 71 53 78 56 46 60 40 34 0.04 48 53 57 44 48 52 39 43 46 34 38 39 29 31 31 2050 126 103 83 114 91 71 99 76 59 84 60 50 65 44 39 0.05 52 58 63 48 53 57 43 47 51 37 42 43 33 35 35 2300 132 108 87 119 95 75 105 80 63 88 63 54 70 47 42 0.06 55 62 68 _,57-1 1 45 51 54 40 45 46 35 39 38 BF-Bypass Factor -Sensible Heat Capacity(1000 Btuh) 0 -Gross Cooling Capacity(1000 Btuh) NOTES: 1. Contact manufacturer for cooling capacities at conditions other than SHC CORRECTION FACTOR shown in table. I 2. Formulas: ENTERING AIR DRY-BULB TEMPERATURE°F(°C) Leaving db = entering db-sensible heat cap. 79(26) 78(26) 77(25) 76(24) 75(24) Under 1.09 x CFM BYPASS 75(24) Leaving wb=wb corresponding to enthalpy of air leaving coil(htwb) FACTOR hj,b=hey b-total capacity(Btuh) 81 (27) 82(28) 83(28) 84(29) 85(29) Over 85 4.5 x CFM Correction Factor where h,,wb = enthaipy of air entering coil. Direct interpolation is permissible.Do not extrapolate. 0.10 .098 1.96 2.94 3.92 4.91 Use 3. SHC is based on 80°F db temperature of air entering coil. Below 0.20 0.87 1.74 2.62 3.49 4.36 formula 80°F db,subtract(Correction Factor x CFM)from SHC.Above 80°F shown db,add(Correction Factor x CFM)to SHC. 0.30 0.76 1.53 2.29 3.05 3.82 below 4. Bypass Factor=0 indicates no psychometric solution.Use bypass factor of next lower EWB for approximation. Interpolation is permissible. Correction Factor=1.09 x(1 -BF)x(db-80) I 13 PERFORMANCE DATA (cont) ESTIMATED SOUND POWER LEVEL(dBA)* UNIT CONDITIONS OCTAVE BAND CENTER FREQUENCY SIZE CFM ESP 63 125 250 500 1000 2000 4000 400 0.25 63.0 59.0 55.0 52.0 50.0 48.0 44.0 600 0.25 64.7 60.7 56.7 53.7 51.7 49.7 45.7 800 0.25 66.0 62.0 58.0 55.0 53.0 51.0 47.0 FV-002 1000 0.25 67.0 63.0 59.0 56.0 54.0 52.0 48.0 1200 0.25 67.8 63.8 59.8 56.8 54.8 52.8 48.8 1400 0.25 68.4 64.4 60.4 57.4 55.4 53.4 49.4 400 0.25 63.0 59.0 55.0 52.0 50.0 48.0 44.0 600 0.25 64.7 60.7 56.7 53.7 51.7 49.7 45.7 800 0.25 66.0 62.0 58.0 55.0 53.0 51.0 47.0 FV-003 1000 0.25 67.0 63.0 59.0 56.0 54.0 52.0 48.0 1200 0.25 67.8 63.8 59.8 56.8 54.8 52.8 48.8 1400 0.25 68.4 64.4 60.4 57.4 55.4 53.4 49.4 636 0.25 65.0 61.0 57.0 54.0 52.0 50.0 46.0 400 0.25 63.0 59.0 55.0 52.0 50.0 48.0 44.0 600 0.25 64.7 60.7 56.7 53.7 51.7 49.7 45.7 800 0.25 66.0 62.0 58.0 55.0 53.0 51.0 47.0 FV-005 1000 0.25 67.0 E60.7 59.0 56.0 54.0 52.0 48.0 1200 0.25 67.8 59.8 56.8 54.8 52.8 48.8 1400 0.25 68.4 60.4 57.4 55.4 53.4 49.4 1600 0.25 69.0 61.0 58.0 56.0 54.0 50.0 600 0.25 64.7 56.7 53.7 51.7 49.7 45.7 800 0.25 66.0 58.0 55.0 53.0 51.0 47.0 1000 0.25 67.0 59.0 56.0 54.0 52.0 48.0 1200 0.25 67.8 59.8 56.8 54.8 52.8 48.8 FV-006 1400 0.25 68.4 64.4 60.4 57.4 55.4 53.4 49.4 1600 0.25 69.0 65.0 61.0 58.0 56.0 54.0 50.0 1800 0.25 69.5 65.5 61.5 58.5 56.5 54.5 50.5 2000 0.25 70.0 66.0 62.0 59.0 57.0 55.0 51.0 2150 0.25 70.3 66.3 62.3 59.3 57.3 55.3 51.3 * Estimated sound power levels have been derived using the method described in the 1987 ASH RAE Systems&Applications Handbook,chapter 52,p.52.7. CFM-Cubic Ft Per Minute ESP-External Static Pressure(in.w.c.) RPM-Revolutions Per Minute AIRFLOW PERFORMANCE CORRECTION FACTORS ATIC PRESSURE HEATER kW ELEMENTS COR ECTION(in.wc) Slze =00 Size 006 0 0 +.02 +.03 5 1 +.01 +.02 8,10 2 0 0 9,15 3 -.02 -.03 20 4 -.04 -.06 18,24,30 6 -.06 -.10 The FV4C airflow performance table was developed using fan coils with 10-kW electric heaters(2 elements)in the units.For fan coils with heaters made up of a different number of elements,the external available static at a given CFM from the table may be corrected by adding or subtracting pressure.Use table for this correction. FACTORY-INSTALLED FILTER STATIC PRESSURE DROP (in. we) UNIT CFM SIZE 400 600 800 1000 1200 1400 1600 1800 2000 002 0.020 0.044 0.048 0.072 0.100 - - - - 003 - 0.020 0.035 0.051 0.070 0.092 - - - 005 - - 0.035 0.051 0.070 0.092 0.120 - - 006 - - - 0.038 0.053 0.070 0.086 0.105 0.133 14 PERFORMANCE DATA (cont) AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PRESSURE DROP (IN. WC) AT INDICATED AIRFLOW (DRY TO WET COIL) UNIT CFM SIZE 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 002 0.012 0.016 0.022 0.028 0.034 0.040 0.049 - - - - 003 - 0.026 0.034 0.042 0.052 0.063 0.075 0.083 1 0.091 0.098 0.110 005 - 0.006 0.008 0.010 0.012 0.015 0.017 0.020 1 0.023 0.027 0.030 CFM 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 006 0.013 1 0.016 1 0.018 0.020 0.023 0.027 0.030 0.034 0.039 0.044 0.048 UNITS WITHOUT ELECTRICAL HEAT MIN BRANCH CIRCUIT UNIT SIZE VOLTS-PHASE FLA CKT Min Wire Fuse/Ckt Bkr AMPS Size Awg* Amps 002 208/230-1 4.3 5.4 14 15 003 208/230-1 4.3 5.4 14 15 005 1 208/230-1 4.3 5.4 14 15 006 1 208/230-1 6.8 8.5 14 15 * Use copper wire only to connect unit,If other than uncoated(non-plated)75°C copper wire(solid wire for 10 AWG and smaller,stranded wire for larger than 10 AWG)is used consult applicable tables of the National Electric Code(ANSI/NFPA 70). NOTE:If branch circuit wire length exceeds 100 ft,consult NEC 210-19a to determine maximum wire length.Use 2%voltage drop. FLA-Full Load Amps ELECTRIC HEATERS INTERNAL FAN COIL HEATING INTELLIGENT HEATER kW VOLTS/ STAGES(kW CIRCUIT SIZE USED CAP.@ HEAT PART NO. @ 240V PHASE OPERATING) PROTECTION WITH 230Vt CAPABLEtt(kW OPERATING) KFCEH0501 N05 5 230/1 5 None All 15,700 - KFCEH0801N08 8 230/1 8 None All 25,100 - KFCEH0901N10 10 230/1 10 None All 31,400 - KFCEH3001 F15 15 230/1 5,15 Fuses** All 47,100 5,10,15 KFCEH3201F20 20 230/1 5,20 Fuses** All 62,800 5,10,15,20 KFCEH2901 N09 9 230/1* 3,9 None All 28,300 3,6,9 KFCEH1601315 15 230/3 5,15 None All 47,100 - KFCEH2O01318 18 230/3 6,12,18 None All 56,500 - KFCEH3401 F24 24 230/3t 8,16,24 Fuses 005,006 78,500 8,16,24 KFCEH3501 F30 30 230/3t 10,20,30 Fuses 005,006 94,200 10,20,30 KFCEH2401 C05 5 230/1 5 Ckt Bkr All 15,700 - KFCEH2501C08 8 230/1 8 Ckt Bkr All 25,100 - KFCEH2601C10 10 230/1 10 Ckt Bkr All 31,400 - KFCEH3101C15 15 230/1 5,15 Ckt Bkr All 47,100 5,10,15 KFOEH3301020 20 230/1 5,20 Ckt Bkr All 62,800 5,10,15,20 *Field convertible to 3 phase. t These heaters field convertible to single phase. t Blower motor heat not included. **Single point wiring kit required for these heaters in Canada. tt Heaters designated with kW Operating Values are Intelligent Heat capable when used with compatible thermostat. ELECTRIC HEATER INTERNAL PROTECTION I j HEATER kW FUSES QTY/SIZE CKT BKR QTY/SIZE* 5 - 1/60 j 8 - 1/60 9 - - 10 - 1/60 15 2/30,2/60 2/60 15 - - 18 - - 20 4/60 2/60 24 6/60 - 30 6/60 - * All circuit breakers are 2 pole. i I j 15 i 3 IT, 1 mil y - - ^ 3 C N # 2 d wo e ccm � J f00 aOD N J N r C I I I I I I I I I I I I I I ig a A 9 An ' o •- rTl J Nt� bp C AG m � m N 3 l l l l l l l a a I I a a I I I I a 3w o o zS�� o cN W ESN d QU o 0 0 0 o I�1 v in U J m a\o r U o m Cl) l l l l l l a a l l a a l l l l w> N m m d v cn W �r 0 1 1 1 1 1 1 1 1 a a I I a a I I I I 3 N y em M z Q m a a o a 3 r Q 2 m m O 0 W �Ui U 3Q 'e _ pa , , , _ aa _ I _ a � I _ _ aa o P/ 0 O O U O o O -6 14 r't Y Fl 7 w o �' o iLJ-+ A O Q�i �o o Z cts O O "M y d aR m U o m o m " ^ m U pp 14 U a H o o Q n Ad Ol l l l l l l l l a a l l l l 0 m C m a 7 d x1--1 N m = L a N •y c 9 9 I l 9 a I I I a 5 CC, v t a w m 01 N � O. N (d U Q N N M N 3 d m I a a A 111 0 0 p cm d i aU F1�--N1I J mN �"cit3 E � ^ — LL N o a O lU 8 ,w T axamw c m —sLLr m FwFSQF Z U Z U Z Z Z V u V Z Z ti. U LL U " m Oas N IL zUa m N"N m l6 ftl E d Q N O N N = L L ld m m ax aulw - .- .- n m - m � 3 � m OC Q O. 2 O'O E N Y r M O .00 m O N m m m n o v o O1 O O E uU - .Q N N th 0) m 7 41 O. x a a 3 E m w > m o d m o •� c 0 3W c ¢QI dtC„ 'Yn SeSU mSmSU ==U „1 xLL imU Y =LLLL =YWYe� Y$ WY x d aLL voLL .Ki }U�U-F xYm d C nQx a—! LL o im"-F NWZ rnaN s U Od LL —z u z i U Z J N z W w - ++U F LL rmC x YOU Y Y ]C I[ Y 16 ACCESSORIES ITEM ACCESSORY PART NO.* FAN COIL SIZE USED WITH 1. Disconnect Kit KFADK0201 DSC Cooling controls and heaters 3-through 10-kW KFACB0201CFB 002 2. Downflow Base Kit KFACB0301 CFB 003,005 KFACB0401 CFB 006 3. Downflow Conversion Kit KFADCO201SLP 003 KFADC0401ACL 002,005,006 4. Single-Point Wiring Kit KFASP0101SPK Only with 15-and 20-kW Fused Heaters KFAFK0212MED 002 5. Filter Kit(12 Pack) KFAFK0312LRG 003,005 KFAFK0412XXL 006 FNCCABBB0017 002 (FILCCFNC0017) 6 Fan Coil Filter Cabinet FNCCABBB0021 003,005 (Fan Coil Filter Media) (FILCCFNC0021) FNCCABBB0024 006 (FILCCFNC0024) GAPABXBB1620 002 (GAPCBBAR1620) 7 Perfect Air' Air Purifier GAPABXBB2020 003,005 (Perfect Air' Purifier Replacement Cartridge) (GAPCBBAR2020) GAPABXBB2420 006 (GAPCBBAR2420) 8. PVC Condensate Trap Kit(50 pack) KFAET0150ETK All 9. Air Cleaner 240-volt Conversion Kit KEAVCO201240 All 10. Downflow/Horizontal Conversion Gasket Kit KFAHDO101 SLP All 11. Airflow Sensor Kit(Air Cleaner) KEAAC0101AAA All 12. ECM Motor Test KFASD0301 VSP All 13. Horizontal Water Management Kit(25 pack) KFAHC0125AAA All KFAFRO101 FRM NA 14. Standard Filter Rack Kit KFAFR0201 FRM 002 KFAFR0301FRM 003,005 KFAFR0401FRM 006 * Factory authorized and listed,field installed. Accessory Kits Description Suggested and Required Use 1. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. SUGGESTED USE:Units for 3-through 10-kW electric resistance heaters and cooling controls. 2. Downflow Base Kit This kit is designed to provide a 1-in.(25MM)minimum clearance between unit discharge plenum,ductwork,and combustible mate- rials.It also provides a gap-free seal with the floor. REQUIRED USE:This kit must be used whenever fan coils are used in downflow applications. 3. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal-left applications.Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications.Separate kits are available for slope coils and A-coils. REQUIRED USE:This kit must be used whenever fan coils are used in downflow,applications. 4. Single Point Wiring Kit The single point wiring kit acts as a jumper between L1 and L3 lugs,and between the L2 and L4 lugs.This allows the installer to run 2 heavy-gauge,high-voltage wires into the fan coil rather than 4 light-gauge,high-voltage wires. SUGGESTED USE:Fan coils with IS-and 20-kW fused heaters only. 5. Filter Kit(12 pack) The kit consists of 12 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean,which increases heat transfer and,in turn,the efficiency of the system. SUGGESTED USE:To replace filters in fan coils. REQUIRED USE:All units unless a filter grille is used. 6. Fan Coil Filter Cabinet This cabinet is mounted to the fan coil on the return air end and designed to slip over the outer fan coil casing. The cabinets are insulated using the same insulation as production fan coils. They are designed for the removal of particulates from indoor air using FILBBFNC00(14,17,21,24)media filter cartridges.These fan coil media filter cartridge kits are designed for the removal of particles from indoor air. The cartridge is installed in the return air duct next to the air handler or further upstream. SUGGESTED USE: All fan coils. 7. Perfect Air' Air Purifier The Perfect Air Purifier wires directly to fan coil and requires no duct transitions with Bryant units. These purifiers both capture and kill airborne viruses,bacteria,mold spores,and allergens. It comes with an airflow sensor. Maintenance is limited to replacement of the purification cartridge,GAPBBAR(1620/2020 or 2420),and inspection/brush cleaning of the ionization array. SUGGESTED USE: All fan coils. 17 ACCESSORIES (cont) 8. Condensate Drain Trap Kit This kit consists of 50 PVC condensate traps.Each trap is pre-formed and ready for field installation.This deep trap helps the system make and hold proper condensate flow even during blower initiation. SUGGESTED USE:All fan coils. 9. Air Cleaner 240-volt Conversion Kit The AIRA electronic air cleaner comes ready for 115-v operation. REQUIRED USE:This kit is required when running 240-volt circuit to air cleaner. 10. Downflow/Horizontal Conversion Gasket Kit This kit provides the proper gasketing of units when applied in either a downflow (FE4A or FE5A) or horizontal (FE4A only) application. REQUIRED USE:Fan coils in either downflow or horizontal applications. 11. Airflow Sensor Kit(Air Cleaner) The AIRA electronic air cleaner comes ready for 115-v operation REQUIRED USE: This kit is required whenever an electronic air cleaner is used. 12. ECM Motor Test Kit Operates variable speed blower at several speeds independent of circuit board and wiring harness. 13. Horizontal Water Management Kit This kit provides proper installation of fan coils under conditions of high static pressure and high relative humidty. SUGGESTED USE: All fan coils. 14. Standard Filter Rack Kit This kit mounts in fan coil filter rack area and modifies the existing filter rack to support standard 1-in.filter sizes. SUGGESTED USE:Fan coils using standard filter sizes. ©2014 Bryant Heating&Cooling Systems•7310 W.Morris St.•Indianapolis,IN 46231 Edition Date: 02/14 U.S.Export Classification:EAR99. Catalog No. PDSFV4C-03 Manufacturer reserves the right to discontinue,or change at any time,specifications or designs without notice and without Incurring obligations. Replaces:PDSFV4C-02 18