HomeMy WebLinkAbout20300 79th Dr Ne_BLD5329_2025 i
Permit Packet Coversheet
Community and Economic Development
City of Arlington • 18204 591h Avenue NE • Arlington,WA 98223 • Phone (360)403-3551
Permit Number: BLD5329 Permit Type: Residential Mechanical
Address/Parcel: 20300 79th Dr Ne Completed (Month/Year): EXPIRED January 2024
Land Use
❑ Notice of Decision ❑ Bonding or Assignment of Funds
❑ Staff Report o Confidential Documents. Contact the
❑ Application City to obtain.
❑ Narrative ❑ Letters and Project Documents
❑ Legal Description ❑ Other:
❑ Vicinity Map
❑ Site Plan Civil
❑ Landscape Plan ❑ Issued Permit
❑ Complete Streets Checklist ❑ Application
❑ Traffic Impact Analysis ❑ Other Applications
❑ Snohomish County Traffic Mitigation Offer ❑ Construction Calculation Worksheet
❑ WSDOT Traffic Offer Form ❑ Approved Plans
❑ Tree Survey ❑ Review Comment Form
❑ Stormwater Drainage Report ❑ Letters and Project Documents
❑ Geotech Report ❑ Other Agency Permits
❑ Critical Area Evaluation Form ❑ Reports:
❑ SEPA Checklist o Drainage Report Pg:
❑ Public Notice Material o Stormwater Pg:
❑ Noticing and Related Documents o Geotech Pg:
❑ Water/Sewer Availability Certificate o All Other Reports
❑ Unanticipated Discovery Plan Form ❑ SEPA and Noticing Materials
❑ Aerial Photo of Site ❑ Inspections
❑ Proposed Building Materials ❑ As-Builts
❑ Lighting Plans and Lighting Cut Sheets ❑ Other:
❑ Color Elevations
❑ Design Matrix Building
❑ Plat Map ❑✓ Issued Permit
❑ Title Report ❑✓ Application
❑ Lot Closures ❑ Additional Applications
❑ Preliminary Civil Plans ❑✓ Approved Plans
❑ Archaeological Survey ❑ Site Plan
o Confidential Documents. Contact the ❑ Letters and Project Documents
City to obtain. ❑ Calculations
❑ Topography(Existing Conditions) ❑✓ Project Specification Manuals
❑ CC&R's ❑ Reports
❑ Deeds/Easements/Conveyances ❑ Certificate of Occupancy
/Dedications ❑ Inspections
❑ Developer's Agreement ❑ Other:
❑ Recorded Copies
Page 1 of 1
CITY OF ARLINGTON
18204 59th Avenue NE,Arlington,WA 98223
INSPECTIONS: 360-403-3417-Permit Center:360-403-3551
BUILDING PERMIT
20300 79TH DR NE Permit#: 5329
Parcel#:00825900001500 PERMIT EXPIRES 180 DAYS AFTER
DATE OF ISSUANCE.
Scope of Work:Replace existing gas furnace with a new gas furnace in the same Valuation:4059.00
location,located in the garage.
OWNER APPLICANT CONTRACTOR
HOOD LOREN J&MICHELE C Day and Nite Plumbing and Heating Day&Nite Plumbing&Heating,Inc
20300 79TH DR NE 16614 13TH AV W 16614 13th Ave W
ARLINGTON,WA 98223 LYNNWOOD Lynnwood,WA 98037
425-775-6464 425-775-6464
LIC:DAYNINP789D5 EXP:03/29/2024
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2018
STORIES: CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any
other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the
Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any
period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance
advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building
official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this
jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,
guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is
determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City
ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor.
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK
AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE
OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND
ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN
MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110.
SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on
your sales tax return form and coded City of Arlington#3101.
&n6:� A A25 GI.Gr�6--347� 05/02/2023
Applicant Signature Date Building Official Date
CONDITIONS
Adhere to approved plans.Call for inspection.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE
PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,
< OTC Residential Mechanical Application
Property Information Contractor(s)
Search properties: Search contractors:
i I
x X
HOOD LOREN J&MICHELE C f,� Day&Nite Plumbing&Heating,Inc
Parcel:oo825900001500 --- Bryan Radcliff
20300 7gTH DR NE
Indieafes Required Field
Applicant Information
Contact: j Bryan Radcliff
I
Phone: 425-775-6464
Email: bryan@edayandnite.net
'Company/Applicant Name: ( Day and Nite Plumbing and Heating �
Company/Applicant Address: 1661413TH AV W
City,State,Zip: LYNNWOOD
Cell Phone:
4257756464
Project Information
Project Name:
Hood
'Scope of Work: Replace existing gas furnace with a new gas furnace in the sa
Project Type: ( Replaced
'Valuation: 4059
SUBMIT ELECTRONIC FILES AND TWO(2)COPIES OF THE FOLLOWING FOR PLAN REVIEW;
Scaled Construction Drawings:
Mechanical Equipment Cut Sheets:
Gas Piping
Pressure Piping Schematic,drawn to scale is Required.Show Pipe size(s)and Length(s)from
meter to all appliances. NOTE:Any interior pressure regulators must be indicated.
New gas piping requires a pressure test hooking to any appliance
Sediment traps(drips)are required on all gas lines
Gas lines are required to be supported/secured per IFGS,Section 415.
Proper Combustion air and venting required for all appliances
A shut-off valve is required within 6 feet of all appliances
Proposed Material:
Proposed Size:
Distance from meter for furthest appliance:
Total BTU's of all appliances:
Number of Units
Air Cond.Unit 5 loo BTU/h: o
Dryer Ducting: 0
i
Exhaust/Vents/Vent Fans: 0
i
Fireplace/Insert/Woodstove: 0
Forced Air Heat 510o BTU/h: I 1
Clothes Dryer-LPG: 0
Gas Fired A/C<_loo BTU/h:
o
1
Gas Piping/Units: i 0 i
Heat Pump-Condensing Unit: 0
Range/Cooktop Gas Fired: 0
Refrigeration Unit 5100 BTU/h: I 0
Range Hood: 0
Wall Heater Gas Fired: 0 1
Water Heater Gas Fired: 0
1 AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN
DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION
OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18,27.THIS APPLICATION IS NOT A PERMIT UNTIL
SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS
UNLAWFUL TO USE OR OCCUPY BUILDING OR STRUCTURE UNTIL FINAL INSPECTION
HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED,
IBCiio/IRCsso,
Signature: Bryan Radcliff
Required Files for OTC Residential Mechanical Application
dsubmitted Without file(s)listed below or with the Wrong file type,application Will not be accepted.
Application Additional Submittal Documents
(File Types:.docx,jpeg,.jpg,.png,or,pdf): (File Types:,docx,jpeg,jpg,.png,or.pdf):
Choose File Application.pdf Choose Flle Spec Sheet.pdf
i
Description of the Application I Description of the Additional Submittal
Documents
Other Files:
Files
Remove i files
Scaled Const Drawing.pdf 19 KB
Choose Files]No file chosen
Pay Fr-:85,
Accessibility
ao3pD
� Funnaee-
Gara9 e.
r7/qfA
1
800SA/801 SA
L,egacy,80, 80%AFUE, Single-Stage, Multi-Speed ECM, i
Non-Condensing Gas Furnaces
0
i
Product Data
PERFORMANCE
® ® Single Stage gas valve
®�— Fixed-Speeds,Constant Torque(FCT)ECM blower motor
dl ®� QuieTechT11'noise reduction system
4 �®����� • Microprocessor based"smart"control center
®� Adjustable heating air temperature rise
®®®® Enhanced diagnostics with LED and reflective sight glass,
non-volatile fault code memory,and self test feature
• Perfect LightTar Igniter
1 • Patented blocked vent safeguard designed to ensure proper furnace
venting
• Inner door for tighter scaling
INSTALLATION FLEXIBILITY
• 4-way Multipoise furnace, 13 vent applications
l HYBRID HEAT®Dual Fuel System compatible
4 All models are chimney friendly when used with accessory vent kit
• Select sizes approved for twinning,refer to accessory kit listing
800SA/801SA GAS FURNACE A190Ifi5 APPLICATIONS
• Compact design-only 33-1/3 in.(847 mm)tall
The 800SA/8015A LegaTMT"r Line 4-way Multipoise Gas Furnaces . propane convertible with gas conversion accessory
feature Bryant's QuieTech noise reduction system for incredibly quiet
induced draft operation. Applications are easy with 4-way multipoise • Convenient Air Purifier and Humidifier connections
design, through-the-fimace downflow venting, 13 different venting CERTIFICATION
options, and designed for easy service access.An inner blower door is
provided for tighter sealing in sensitive applications.The 800SA/801SA Cabinet air leakage less than 2.0% at 10 in, W.C. and cabinet air
furnaces are approved for use with natural or propane gas, and the leakage less than 1.4%at 0.5 in.W.C.when tested in accordance with
801SA-Low NOx units are designed for California installations and can ASHRAE standard 193
be installed in air quality management districts with a 40 ng/J NOx Residential installations eligible for consumer financing through the
emissions limit. Retail Credit Program
�E 51 G,y srrtt����4
J
P �
CFRTIF���® IS09001,
Quality
LEGACY
LINE
Use of the AM Certified W Mark indicates a
rnanufaoturer'a parNdpation in the program.For
verificadon of cardficaticn for individual products,
go to wwwehridirectoryorg.
A210031
800SA/801SA:Product Data
s,
SPECIFICATIONS
Unit Size 71
r 36045E14 36045E17 36070E14 36070E17 4807OE17 4807OE21 42090E17
RATINGS AND PERFORMANCE
Input Btuh* All Standard 44,000 44,000 66,000 66,000 66,000 66,000 88,000
All Low NOx Upflow
Nonweatherized ICS All Low Nox 42,000 42,000 63,000 63,000 63,000 63,000 84,000
Downflow/Horizontal
Output Capacity All Standard
(Btuh)t All Low NOx Upflow 36,000 35,000 54,000 54,000 54,000 53,000 71,000
Nonweatherized ICS All Low Nox 34,000 34,000 51,000 51,000 51,000 51,000 68,000
Downflow/Horizontal
AFUEt 80%
Certified Temperature Rise Range-*F(`C) 30-60 30-60 30-60 35-65 25-55 25-55 40-70
(17-33) (17-33) (17-33) (19-36) (14-30) (14-30) (22-39)
Certified External Heat/Cool 0.10/0.50 0.10/0.50 0.12/0.50 0.12/0.50 0.12/0.50 0.12/0.50 0.15/0.50
Static Pressure
Heating 710 760 1090 985 1175 1305 1203
Airflow CFM$ Cooling 1080 1215 1070 1005 1515 1545 1210
ELECTRICAL
Unit Volts-Hertz-Phase 115-60-1
Operating Voltage
Min Max 104-127
Range
Maximum Unit Amps 5.6 7.6 5.6 5.6 10.8 10.0 8.3
Unit Ampacity 7.8 10.3 7.8 7.8 14.3 13.3 11.0
Maximum Wire Length 47(14.3) 36(11) 47(14.3) 47(14.3) 25(7.6) 27(8.2) 33(10.1)
(Measure 1 Way In Ft(M)
Minimum Wire Size 14
Maximum Fuse or Ckt Bkr Size(Amps)*" 15
Transformer(24v) 40va
External Control Heating 12va
Power Available Cooling 35va
Air Conditioning Blower Relay Standard
Controls
Heating Blower Control Solid State Time Operation
Burners(Monoport) 2 2 3 3 3 3 4
Gas Connection Size 1/2in.NPT
GAS CONTROLS
Mfr WhiteRodgers
Gas Valve Min.inlet pressure 4.5(Natural Gas)
(Redundant) (In.W.C.)
Max.inlet pressure 13.6(Natural Gas)
(In.W.C.)
Ignition Device Hot Surface
Factory installed orifice Size 43
BLOWER DATA
Direct Drive Motor HP 1/3 1/2 1/3 1/3 3/4 3/4 1/2
Motor Full Load Amps 4.4 6.4 4.4 4.4 9.60 8.8 6.8
RPM(Nominal)Speeds 1050-5 1050-5 1050-5 1050-5 1050-5 1050-5 1050-5
Blower Wheel Diameter x Width -In.(mm) 10 x 6 10 x 8 10 x 6 11 x 8 11 x 8 10 x 10 11 x 8
(254 x 152) (254 x 203) (254 x 152) (279 x 203) (279 x 203) (254 x 254) (279 x 203)
*. Gas input ratings are certified for elevations to 2000 ft.(610 M). In USA,For elevations above 2000 ft(610 M),reduce ratings 4 percent for each 1000 ft(305 M)above sea
level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table FA or furnace installation instructions,
t. Capacity in accordance with U.S.Government DOE test procedures,
$. Airflow shown is for bottom only return-air supply for the as-shipped speed tap,For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required
for each return-air supply.An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in.(110 mm)wide,high efficiency media filter..
**, Time-delay type is recommended.
ICS=Isolated Combustion System
Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations.
2
800SA/801 SA:Product Data
SPECIFICATIONS (continued)
Unit Size 4809OE21 6009OE21 6009OE24 6011OE21 60110E24 60135E24 60155E24
RATINGS AND PERFORMANCE
All Standard 88,000 88,000 88,000 110,000 110,000 132,000 154,000
Input Btuh' All Low NOx Upflow
Nonweatherized ICS All Low NOx 84,000 84,000 84,000 105,000 105,000 126,000 147,000
Downflow/Horizontal
Output Capacity All Standard 72,000 71,000 72,000 90,000 90,000 107,000 125,000
(Btuh)t All Low NOx Upflow
Nonweatherized ICS All Low NOx 68,000 68,000 69,000 85,000 86,000 102,000 119,000
Downflow/Horizontal
AFUEt 80%
Certified Temperature Rise Range°F(°C) 35-65 25-55 30-60 30-60 30-60 40-70 45-75
(19-36) (14-30) (17-33) (17-33) (17-33) (22-39) (25-41)
Certified External Heat/Cool 0,15/0.50 0.15/0.50 0.15/0.50 0.20/0.50 0.20/0.80 0,20/0.50 0.20/0.50
Static Pressure
Heating 1418 1650 1565 1890 1930 1760 1950
Airflow CFM$ Cooling 1445 1980 1960 2040 2005 1810 1965
Electrical
Unit Volts-Hertz-Phase 115-60-1
Operating Voltage Min-Max 104-127
Range
Maximum Unit Amps 8.3 13 10.3 13.4 10.7 10.7 10.7
Unit Ampacity 11 16.90 13.50 17.40 14 14 14
Maximum Wire Length (Measure 1 Way in Ft 33(10.1) 34(10.4) 27(8.2) 33(10.1) 26(7.9) 26(7.9) 26(7.9)
(M))
Minimum Wire Size 14 12 14 12 14 14 14
Maximum Fuse or Ckt Bkr Size(Amps)** 15 20 15 20 15 15 15
Transformer(24v) 40va
External Control Heating 12va
Power Available Cooling 35va
Air Conditioning Blower Relay Standard
CONTROLS
Heating Blower Control SolidState Time Operation
Burners(Monoport) 4 4 4 5 5 6 7
Gas Connection Size 1/21n.NPT
GAS CONTROLS
Mfr. WhiteRodgers
Gas Valve Min,inlet pressure 4.5(Natural Gas)
(Redundant) (In.W.C,)
Max.inlet pressure
13.6(Natural Gas)
(In.W,C.)
Ignition Device Hot Surface
Factory installed orifice Size 43
BLOWER DATA
Direct Drive Motor HP 1/2 1 3/4 1 3/4 3/4 3/4
Motor Full Load Amps 6.80 11.50 8.80 11.50 8.80 8.80 8.80
RPM(Nominal)Speeds 1050-5 1050-5 1050-5 1050-5 1050-5 1050-5 1050-5
Blower Wheel Diameter x Width-In.(mm) 10 x 10 11 x 11 11 x 11 11 x 11 11 x 11 11 x 11 11 x 11
(254 x 254) (279 x 279) (279 x 279) (279 x 279) (279 x 279) (279 x 279) (279 x 279)
*, Gas input ratings are certified for elevations to 2000 ft.(610 M). In USA,for elevations above 2000 ft.(610 M),reduce ratings 4 percent for each 1000 ft.(305 M)above sea
level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table FA or furnace installation instructions.
t. Capacity in accordance with U,S.Government DOE test procedures.
$. Airflow shown is for bottom only return-air supply for the as-shipped speed tap.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required
for each return-air supply.An airflow reduction ofup to 7 percent may occur when using the factory-specified 4-5/I6-in.(I 10 nmm)wide,high efficiency media filter..
**. Time-delay type is recommended.
ICS=Isolated Combustion System
Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations.
3
800SA/801SA:Product Data
MODEL NUMBER NOMENCLATURE
1 2 3 4 5 6,7 8-10 11 12-13 14 15 16
Heat Major Cooling Voltage Minor
Exchanger Tler/NOx AFUE/NOx Heating Stages Series Capacity(CFM) Heating Input Motor Type Width (1-phase) Un-used Series
9 8 7 M B 42 060 C 17 A - A
C=Comm,Variable-
8 Speed Ee
0-80% Constant Airflow 4=
14,20=Base 1=80%Low Nox (VCA)ECM VfiH 1=Legacy Line ---- 17-175
E=Fixed-Speeds -2=92% Constant Torque 21=21,0
2=Preferred 24=24,5"
6=95% (FCT)ECM
3=Ultra Law Nox 24=800 CFM
8=Evolution 6=96% 30=1000 CFM 026=26,000 BTUh V=Variable-Speed
7=979b 040=40,000 BTUh Constant Torque
8=98% M=Modulating A 36=1200 CFM 060=60,000 BTUh (VCT)ECM
1;=Single Stage B 42=1400 CFM
T=Two-Stage C 48=1600 CFM 155=155,000 RTUh
D 60=2000 CFM
--- 66=2200 CFM
A200522
FURNACE COMPONENTS
INDUCER MOTOR VENT
ASSEMBLY F ELBOW
- MAIN LIMIT SWITCH
PRESSURE - (BEHIND GAS VALVE)
SWITCH
BLOCKED VENT
SWITCH
FLUE COLLECTOR
BOX a FLAME
OAS VALVE SENSOR
�I
o
MANUAL RESET GAS MANIFOLD
LIMIT SWITCHES o
r
HOTSURFACE
IGNITOR
GAS BURNER
1 0
BLOWER
DOOR SAFETY
SWITCH
FURNACE
CONTROL BLOWER AND
BOARD m MOTOR
I�
i
A 190086
NOTE:The furnaces are factory shipped for use with natural gas.These furnaces can be field-converted for propane gas with a factory-authorized and
listed accessory conversion kit.
Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations.
4
i
800SA/801SA:Product Data
ACCESSORIES
DESCRIPTION PART NO. 36045E14 ,�36045E17 3607OE14 36070E17 48070E17 4807OE21 42090E17
FHG1425-2 X -
External Bottom Return Filter Rack' FHG1625-2 X - X X X
FHG2025-2 - X
Unframed Filter 3/4-in.(19 mm)' 325531-402 X X X X X X
325531-403 X
Flue Extension KGAFE0112UPH X X X X X X X
Combustible Floor Base KGASB0201ALL X X X X X X X
Downflow Vent Guard KGBVG0101DFG X X X X X X X
Vent Extension Kit KGAVE0101DNH X X X X X X X
KGADA0101ALL X X X X X X X
Coil Adapter Kit KGADA0201ALL X X X X X X X
KGADA0301ALL X X X X X X X
Chimney Adapter Kit KGACA02014FC X X X X X X X
Natural-to-Propane Conversion Kitt AGAGC8NPS01A X X X X X X X
Propane-to-Natural Conversion Kitt AGAGC8PNS01A X X X X X X X
Twinning Kit FCT-ECM Motor AGATWNDTE01A X
Blower Speed Tap Jumper Kit AGABLRJMP10A X X X X X X X
(10 pack)
*. Purchased through Replacement Components
t. Factory-authorized and field installed.Fuel conversion kits are CSA(formerly AGA/CGA)recognized.
X=Accessory
DESCRIPTION PART NO. 4809OE21 6009OE21 6009OE24 60110E21 60110E24 60135E24 60155E24
External Bottom Return FHG2025-2 X X X
Filter Rack FHG2424-2 X X X X
Unframed Filter 3/4-in. 325531-403 X X X
(19 mm)* 325531-404 X X X X
Flue Extension KGAFE0112UPH X X X X X X X
Combustible Floor Base KGASB0201ALL X X X X X X X
Downflow Vent Guard KGBVG0101 DFG X X X X X X X
Vent Extension Kit KGAVE0101DNH X X X X X X X
KGADA0101ALL X X X X X X X
Coil Adapter Kit KGADA0201ALL X X X X X X X
KGADA0301ALL X X X X X X X
Chimney Adapter Kit KGACA02014FC X X X X X
KGACA02015FC - X X
Natural-to-Propane
AGAGC8NPS01A X X X X X X X
Conversion Kitt
Propane-to-Natural AGAGC8PNS01A X X X X X X X
Conversion Kitt
Twinning Kit FCT-ECM AGATWNDTE01A X X X X X X X
Motor
Blower Speed Tap Jumper
Kit AGABLRJMP10A X X X X X X X
(10 pack)
*. Purchased through Replacement Components
1. Factory-authorized and field installed.Fuel conversion kits are CSA(formerly AGA/CGA)recognized.
X=Accessory
ORFICIES
Gas Orifice Kit-#42(Nat Gas) LH32DB207
Gas Orifice Kit-#43(Nat Gas) LH32DB202
Gas Orifice Kit-#44(Nat Gas) LH32DB200
Gas Orifice Kit-#45(Nat Gas) LH32DB205
Gas Orifice Kit-#46(Nat Gas) LH32DB208
Gas Orifice Kit-#47(Nat Gas) LH32DBO78 See Installation Instructions for model,altitude,
Gas Orifice Kit-#48(Nat Gas) LH32DBO76 and heat value usages.
Gas Orifice Kit-#54(LP) LH32DB203
Gas Orifice Kit-#55(LP) LH32DB201
Gas Orifice Kit-#56(LP) LH32DB206
Gas Orifice Kit-1.25mm(LP) LH32DB209
Gas Orifice Kit-1.30mm(LP) LH32DB210
Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations.
5
800SA/801SA:Product Data
ACCESSORIES
DESCRIPTION ACCESSORY
HUMIDIFIER Model HUM
HEAT RECOVERY VENTILATOR Model HRV
ENERGY RECOVERY VENTILATOR Model ERV
UV LIGHTS Model UVL
Bryant has a wide variety of thermostats for your system,please visit www.Bryant.com to see all thermostat and IAQ products.
DESCRIPTION ACCESSORY 14" 17" 21" 24"
Bryant Carbon Monoxide Alarm(10 pack) COALMBBNRB02-A10 X X X X
Bryant Evolution Air Purifier-16x25(407x635 mm) DGAPAXX1625 X X -
Bryant Evolution Air Purifier-20x25(508x635 mm) DGAPAXX2025 X X
Bryant Evolution Air Purifier Rep].Filter-16x25(407x635 mm) GAPBBCAR1625-A05 X X
Bryant Evolution Air Purifier Repl.Filter-20x25(508x635 mm) GAPBBCAR2025-A05 X X
Cartridge Media Filter-16"(407 mm)(MERV 11) FILXXCAR0116 X X
Cartridge Media Filter-16"(407 mm)(MERV 8) FILXXCAR0016 X X
Cartridge Media Filter-20"(508 mm)(MERV 8) FILXXCAR0020 - X
Cartridge Media Filter-20"(508 mm)(MERV11) FILXXCAR0120 - X
Cartridge Media Filter-24"(610 mm)(MERV 8) FILXXCAR0024 X
Cartridge Media Filter-24"(610 mm)(MERV11) FILXXCAR0124 - - X
EZ Flex Cabinet Side or Bottom-16" EZXCAB--0016 X X -
EZ Flex Cabinet Side or Bottom-20" EZXCAB--0020 - X X
EZ Flex Replacement Filters 16" MERV 10 EXPXXFIL0016 X X
EZ Flex Replacement Filters 16" MERV 13 EXPXXFIL0316 X X
EZ Flex Replacement Filters 20" MERV 10 EXPXXFIL0020 - - X
EZ Flex Replacement Filters 20" MERV 13 EXPXXFIL0320 - - X
EZ Flex Replacement Filters 24" MERV 10 EXPXXFIL0024 - - X
EZ Flex Replacement Filters 24" MERV 13 EXPXXFIL0324 - - X
EZ-Flex Filter with End Caps-16"(407 mm)(MERV 10) EXPXXUNVO016 X X -
EZ-Flex Filter with End Caps-16"(407 mm)(MERV 13) EXPXXUNV0316 X X -
EZ-Flex Filter with End Caps-20"(508 mm)(MERV 10) EXPXXUNVO020 - X
EZ-Flex Filter with End Caps-20"(508 mm)(MERV 13) EXPXXUNV0320 - X
EZ-Flex Filter with End Caps-24"(610 mm)(MERV 10) EXPXXUNVO024 - - X
EZ-Flex Filter with End Caps-24"(610 mm)(MERV 13) EXPXXUNV0324 - X
Media Filter Cabinet-20" FILGABXL0020 - X -
Media Filter Cabinet-24" FILCABXL0024 - X
Media Filter Cabinet-16" FILCABXL0016 X X - -
TYPICAL WIRING SCHEMATIC
---- FIELD 24-V WIRING
---- FIELD 115-,208/230-,460-V WIRING
— FACTORY 24-V WIRING
— FACTORY 115-V WIRING
NOTE 2 THERMOSTAT
FIVE WIRE w e R G Y TERMINALS FIELD-SUPPLIED
THREE-WIRE I I I I I DISCONNECT
HEATING-ONLY I I I I I
BLOWER DOOR SWITCH I I 1 I I == 460-V 0 OR
I I —_— THREE
PHASE
�
WH `' l'.J ---i--� i I
O I 1 I
N i i i -- --- 208/230-V
=GND GND SINGLE
R G ___�____--_I I 0 PHASE
115-V FIELD AUXILIARY O i 1 ♦_ _ ___ -__-----
SUPPLIED ----------- Ir =GND
SUPPLIED L ^
DISCONNECT ____NOTE 1____; k:_
CONDENSING
Y ------
UNIT
24-V TWO
TERMINAL WIRE
BLOCK
FURNACE NOTES: 1. Connect Y-terminal in furnace as shown for proper blower operation.
2. Some thermostats require a"C"terminal connection as shown.
3. If any of the original wire,as supplied,must be replaced,use
same tvne or eaulvalent wire,
A 190079
Representative drawing only,some models may vary.
Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations.
6
800SA/801SA:Product Data
AIR DELIVERY - CFM (with filter)
Wire Test Airflow Delivery @ Various External Static Pressures
Furnace Lead Function
Color 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0,8 0.9 1
Gray Cooling.Do not use for heating. 1230 1190 1155 1120 1080 1045 1010 975 935 895
Yellow Alt Cooling or alt Heating 980 945 920 890 855 815 770 735 690 645
36045E14 �� Orange Alt Cooling or alt Heating 770 720 685 640 600 560 520 475 430 385
Blue Heating or alt Cooling 710 660 620 580 540 490 455 415 375 335
Red Alt Cooling.Do not use for heating. 600 540 500 455 415 385 345 305 235 -
Gray Cooling.Do not use for heating. 1370 1335 1295 1255 1215 1175 1135 1095 1055 1020
Yellow Alt Cooling or alt Heating 1130 1085 1040 995 955 910 865 825 780 730
36045E17 Orange Alt Cooling or alt Heating 930 885 835 795 745 700 655 600 545 495
Blue Heating or alt Cooling 760 720 670 625 580 515 460 410 355 300
Red Alt Coolin .Do not use for heatin . 610 500 445 375 320 260 200 135 -
Gray Cooling.Do not use for heating. 1205 1170 1143 1105 1070 1035 1000 960 925 885
Blue Heating or alt Cooling 1095 1060 1030 995 960 925 885 840 800 735
3607OE14 Yellow Alt Cooling or alt Heating 920 880 845 805 765 730 685 620 560 510
Orange Alt Cooling.Do not use for heating. 715 650 610 575 520 465 410 380 305 245
Red Alt Cooling.Do not use for heating. 635 490 445 375 315 270 205 230 190 140
Gray Cooling.Do not use for heating. 1185 1140 1095 1055 1005 960 915 865 820 780
Yellow Alt Cooling or all Heating 1000 940 895 850 800 750 695 650 600 555
36070E17 Blue Heating or all Cooling 990 935 895 845 790 740 690 640 590 535
Orange Alt Cooling or all Heating 855 775 720 660 605 560 495 435 385 335
Red Alt Cooling.Do not use for heatin . 860 685 515 445 385 340 275 205 -
Gray Cooling.Do not use for heating. 1650 1615 1580 1545 1515 1480 1445 1415 1380 1350
Yellow Alt Cooling.Do not use for heating. 1405 1365 1325 1285 1250 1215 1175 1140 1100 1065
48070E17 Orange Alt Cooling or all Heating 1255 1215 1175 1130 1090 1050 1010 970 930 895
Blue Heating or alt Cooling 1185 1140 1095 1050 1005 965 920 880 840 800
Red Alt Cooling.Do not use for heating. 1100 1050 1005 960 915 870 825 785 740 700
Gray Cooling.Do not use for heating. 1735 1685 1640 1595 1545 1495 1450 1405 1360 1310
Yellow Alt Cooling or all Heating 1480 1435 1395 1340 1290 1240 1190 1135 1085 1030
4807OE21 Blue Heating or alt Cooling 1315 1275 1225 1180 1135 1085 1030 975 915 860
Orange Alt Cooling or all Heating 1135 1080 1030 985 935 885 835 770 705 645
Red Alt Cooling.Do not use for heatin . 980 930 875 820 775 715 665 595 530 455
Gray Cooling,Do not use for heating. 1355 1320 1285 1245 1210 1165 1125 1080 1025 815
Yellow Alt Cooling or alt Heating 1295 1255 1220 1185 1140 1100 1055 1005 955 815
4209OE17 Blue Heating or alt Cooling 1220 1185 1150 1105 1065 1025 975 915 840 740
Orange Alt Cooling or alt Heating 1030 985 940 900 845 790 715 655 590 535
Red Alt Cooling.Do not use for heating. 945 905 855 800 750 670 600 540 490 435
Gray Cooling.Do not use for heating. 1625 1580 1535 1490 1445 1395 1340 1260 1135 995
Yellow Alt Cooling or alt Heating 1425 1380 1335 1290 1235 1185 1125 1075 1020 640
4809OE21 Blue Heating or alt Cooling 1440 1395 1350 1305 1255 1200 1145 1090 1040 950
Orange Alt Cooling or alt Heating 1260 1210 1160 1105 1050 990 935 880 820 755
Red Alt Cooling.Do not use for heatin . 1095 1040 980 905 845 780 720 650 585 520
Gray Cooling.Do not use for heating. 2180 2130 2080 2030 1980 1925 1870 1805 1745 1680
Yellow Alt Cooling or all Heating 1900 1845 1795 1740 1685 1635 1570 1500 1435 1375
6009OE21 Blue Heating or alt Cooling 1685 1620 1565 1505 1455 1385 1320 1260 1200 1140
Orange Alt Cooling or alt Heating 1390 1315 1240 1175 1095 1030 970 900 825 760
Red Alt Cooling.Do not use for heatin . 1240 1155 1075 990 915 835 765 690 615 555
Gray Cooling.Do not use for heating. 2190 2135 2075 2015 1960 1900 1835 1775 1705 1630
Yellow Alt Cooling or alt Heating 1870 1810 1745 1685 1625 1565 1495 1420 1345 1280
6009OE24 Blue Heating or all Cooling 1580 1510 1445 1385 1320 1240 1175 1115 1050 970
Orange Alt Cooling or all Heating 1305 1220 1160 1075 1000 930 865 770 690 610
Red Alt Cooling.Do not use for heating. 1210 1075 1000 915 845 765 675 595 515 425
Gray Cooling.Do not use for heating. 2255 2205 2150 2100 2040 985 1920 835 735 6 5
Blue Heating or all Cooling 1945 1890 1830 1770 1715 1655 1600 1545 1480 1430
6011OE21 Yellow Alt Cooling or all Heating 1600 1525 1465 1400 1335 1275 1210 1150 1080 1015
Orange Alt Cooling.Do not use for heating. 1420 1340 1280 1200 1140 1065 1005 925 865 790
Red Alt Cooling.Do not use for heatin . 1280 1205 1140 1055 990 910 840 760 695 630
Gray Cooling.Do not use for heating. 2250 2190 2130 2070 2005 1950 1885 1820 1755 1685
Blue Heating or all Cooling 1995 1930 1865 1800 1740 1670 1605 1535 1465 1400
60110E24 Yellow Alt Cooling.Do not use for heating. 1540 1460 1385 1305 1235 1165 1095 1035 955 890
Orange Alt Cooling or alt Heating 1345 1195 1135 1055 980 920 845 770 695 620
Red Alt Cooling.Do not use for heating. 1335 1075 965 890 820 735 660 580 505 440
Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations.
7
800SA/801SA:Product Data
AIR DELIVERY - CFM (with filter) (Continued)
Wire Test Airflow Delivery @ Various External Static Pressures
Furnace Lead Function 0,1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Color
Gray Cooling.Do not use for heating, 2065 2005 1940 1875 1810 1740 1670 1600 1530 1470
Blue Heating or alt Cooling 1825 1760 1695 1630 1560 1490 1420 1350 1275 12M
60135E24 Yellow Alt Cooling or alt Heating 1760 1690 1625 1555 1485 1415 1345 1275 1200 1130
Orange Alt Cooling.Do not use for heating. 1620 1550 1480 1405 1335 1260 1195 1130 1065 995
Red Alt Cooling.Do not use for heaiin 1325 1260 1 1185 1 1100 1025 1 955 885 1 805 735 1 670
Gray Cooling.Do not use for heating. 2205 2150 2090 2030 1965 1905 1840 1780 1710 1645
Blue Heating or all Cooling 2055 1995 1935 1875 1810 1750 1690 1615 1540 1460
60155E24 Yellow Alt Cooling or all Heating 1860 1795 1730 1670 1605 1540 1470 1395 1320 1250
Orange Alt Cooling.Do not use for heating. 1495 1430 1355 1285 1210 1130 1065 995 930 850
Red Alt Cooling.Do not use for heating. 1295 1085 1000 910 835 765 670 600 530 465
FOOTNOTES
LA filter is required for each return-air inlet.Airflow performance included 3/4-in.(19 mm)washable filter media(see accessory list).To determine airflow performance without this filter,
assume an additional 0.1 In,W.C.available external static pressure.
2.Adjust the blower speed tabs as necessary for the proper air temperature rise for each installation.
3.--Indicates unstable operating conditions.
4.I17 the same motor speed tap is needed for heating and cooling,a Jumper Wire accessory kit is available(see Product Data sheet for the current Jumper Wire accessory part number),see
Function column for applicable limitations.
1" uitLLID
1\\ ro-I
SEE NOTES:1,2,4,5,7,8,9 O
.t
A02068
HORIZONTAL RIGHT SEE NOTES:1,2,4,5,7,8,9
A02065
i' HORIZONTAL LEFT
O
--- UrLa1111
SEE NOTES:1,2,4,7,8,9 0
A02069 0
HORIZONTAL RIGHT 1
)iLUMJ� SEE NOTES:1,2,4,5,7,8,9
=- HORIZONTAL LEFT A02066
O
a
'• a
SEE NOTES:1,2,4,5,7,8,9
HORIZONTAL RIGHT A02070 SEE NOTES:1,2,4,5,7,8,9
HORIZONTAL LEFT A02067
d
O
.1
SEE NOTES:1,2,4,7,8,9
HORIZONTAL LEFT n02064
Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations.
8
800SA/801SA:Product Data
u"u➢ui'
1 -
O O
Q o'
SEE NOTES:1,2,3,4,5,7,8,9
SEE NOTES:1,2,4,7,8,9 DOWNFLOW A02060
A02058
UPFLOW
o O
O o.
SEE NOTES:1,2,3,4,7,6,9
SEE NOTES:1,2,3,4,7,6,9
A020S9 A02063
UPFLOW DOWNFLOW
f i➢u��,]
1 d Luu4
O O
•0•
SEE NOTES:1,2,4,5,6,7,6,9
SEE NOTES:1,2,4,5,7,8,9 DOWNFLOW A02062
A02061
DOWNFLOW
VENTING NOTES
1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas Code (NFGC), ANSI
Z223.1/NFPA 54,
2. Immediately increase to 5-in.(127 mm)vent connector outside furnace casing when 5-in.(127 nun)vent connector required,refer to Note 1.
3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace,except when Downflow Vent
Guard is used in downflow position,
4. Type B vent where required,refer to Note 1,
5. 4-in,(102 mm)single wall vent must he used inside furnace casing and the Downflow Vent Guard Kit,
6. Accessory Downflow Vent Guard Kit required in downflow installations with bottom vent configuration.
7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kits for sizing and complete application
details.
8. Secure vent connector to furnace elbow with(2)corrosion-resistant sheet metal screws,space approximately 180 apart.
9. Secure all other single wall vent connector joints with (3) corrosion-resistant screws spaced approximately 120 apart. Secure Type B vent
connectors per vent connector manufacturer's recommendations.
Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations.
9
800SA1801SA:Product Data
DIMENSIONS
16 IIN----
r IG4).41
fI
D __..I
S�ii lfH I/Y � f IIB
— 1 illt
151 61
C 1 ..IS)a
I
Ilf'lYn �—I;i Il6
111.11 -------2i 1•/14-------
M1if[S'fIY I11 1502.41
11 1l1-
I IS/In 1511.tl1 -12 9114
i If/6 � 111 11 11 M1 —._ Is)s,11
1111 JI
1 5s 1l2 y 1Y,6/BI A _ 1Y)Ifi
1110 AIA r)r, -1-- (119 s1 I!I IIYI u I III -�
IS 1 it 1l1111 1 ��2�11 ��u u u 1111.11 / 111 it 1 1 1)116
[i _ � 1..1104 P/ u u u u Y 9l 4 i. III 1( AI I E(NINY 1 11_AI 111!/11
I i;U il�- _ _ _. u u u u � •�
— Y
ii u u
I12�YJ WI Jll 110)II I
iY jN ,tF/nnl In[Pliwl 111.5) 11 OIIpp fll d r /''
I J01 11 I SA)ItlIAI IiYU.I1 11'J i
W I•I � I I A 1�t�ar � -- —
t
pill,
il 159111 1 i� izi/il �Y r�rslncn
L—_—_—_---_ -------------
11 SIE E Ire <i1 Pi� 21 I/la 1
1519.51 0)IIIN Inl[1 1155,11 1 1/ v(ilil CL 5 I.:I 6Jii1 Stull W 11
i Im_ onru room na�il :c In dnl Inln iYiln
n .n 19 "1^ laue.oi iiJi/ii 1
I1J6.11
A 190084
TOP AND D VENT
A B BOTTOM FLUE BOTTOM CONNECTION SHIP WT.LB.
FU CE SIZE CABINET WIDTH OUTLET WIDTH COLLAR INLET WIDTH SIZE (KG)
36045E14 14-3/16(360) 12-9/16(319) 9-5/16(237) 12-11/16(322) 4(102) 104(47)
36045E17 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 119(54)
3607OE14 14-3/16(360) 12-9/16(319) 9-5/16(237) 12-11/16(322) 4(102) 114(52)
3607OE17 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 120(54)
4807OE17 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 126(57)
4807OE21 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 142(64)
4209OE17 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 131 (49)
4809OE21 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 137(62)
60090E21 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 140(64)
6009OE24 24-1/2(622) 22-7/8(581) 15-1/16(383) 23(584) 4(102) 146(66)
601IOE21 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 146(66)
601IOE24 24-1/2(622) 22-7/8(581) 15-1/16(383) 23(584) 4(102) 161 (73)
60135E24 24-1/2(622) 22-7/8(581) 15-1/16(383) 23(584) 4(102)' 167(76)
60155E24 24-1/2(622) 22-7/8(581) 15-1/16(383) 23(584) 4(102)n 168(76)
*. 135 and 155 size furnaces require a 5 or 6-in,(127 or 152 mm)vent, Use a vent adapter between furnace and vent stack. See Installation
Instructions for complete installation requirements.
Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations.
10
800SA/801 SA:Product Data
GUIDE SPECIFICATIONS Filters
Gas Furnace Furnace may have reusable-type filters.Filter shall be in,(mm)
800SA/801 SA W in, (mm). An accessory high efficiency Media Filter is
available as an option. Media Filter.
Casing
General Casing shall be of.030 in.(.76)thickness minimum,pre-painted steel.
SYSTEM DESCRIPTION Inducer Motor
Furnish a fixed capacity gas-fired furnace for use Inducer motor shall be soft mounted to reduce vibration transmission.
with natural gas or propane(factory authorized conversion kit required Draft Safeguard Switch
for propane);furnish cold air return plenum. Draft Safeguard Switch (blocked vent safeguard) shall be factory
QUALITY ASSURANCE installed to reduce the possibility of vent gas infiltration due to a blocked
Unit will be designed, tested and constructed to the current ANSI Z or restricted vent pipe.
21,47/CSA 23 design standard for gas-fired central furnaces. Heat Exchangers
Unit will be 3rd party certified by CSA to the current ANSI Z Heat exchangers shall be a 4-Pass 20 gage aluminized steel of
21.47/CSA 2.3 design standard for gas-fired central furnaces. fold-and-crimp sectional design when applied operating under negative
Unit will carry the CSA Blue Star@O label. pressure.
Unit efficiency testing will be performed per the current DOE test Controls
procedure as listed in the Federal Register. Control shall include a micro-processor based integrated electronic
Unit will be certified for capacity and efficiency and listed in the latest control board with at least 11 service troubleshooting codes displayed
AHRI Consumer's Directory of Certified Efficiency Ratings, via enhanced flashing LED diagnostic light on the control, a self-test
Unit shall carry the current Federal Trade Commission Energy Guide feature that checks all major functions of the furnace within one minute,
efficiency label, and a non-volatile memory replaceable automotive-type circuit
DELIVERY STORAGE AND HANDLING protection fuse, Multiple operational settings available including,
Unit shall be shipped as single package only and is stored and handled separate blower speeds for heating,cooling and continuous fan.Cooling
per unit manufacturer's recommendations. airflow will be selectable between 350 or 400 CFM per ton of air
WARRANTY(for inclusion by specifying engineer) conditioning.
OPERATING CHARACTERISTICS
Warranty certificate available upon request. Heating Capacity shall be Btuh input; Btuh output
EQUIPMENT capacity.
Components shall include: slow-opening gas valve to reduce ignition Fuel Gas Efficiency shall be 80% AFUE. Air delivery shall be
noise,regulate gas flow,with electric switch gas shut-off;flame proving CFM minimum at 0,50 In.W.C.external static pressure.
sensor, hot surface igniter, pressure switch assembly, flame rollout Dimensions shall be: depth in.(mm);width in.
switch, blower and inducer assembly, 40va transformer; low-voltage (rnm)' height in, (mm) (casing only). Height shall
(heating)(heating/cooling)thermostat,
be in. (mm) with A/C coil and in. (mm)
Blower Wheel and Blower Motor overall with plenum.
Galvanized blower wheel shall be centrifugal type, statically and ELECTRICAL REQUIREMENTS
dynamically balanced. Blower motor of fixed-speeds, constant torque Electrical supply shall be 115 volts, 60 Hz, single-phase (nominal).
ECM type shall be permanently lubricated with sealed bearings, of Minimum wire size shall be AWG; maximum fuse size or
hp,and shall be multiple-speed direct drive.Blower motor shall circuit breaker shall be Amps.
be soft mounted to the blower scroll to reduce vibration transmission, SPECIAL FEATURES
Refer to section of the product data sheet identifying accessories and
descriptions for specific features and available enhancements.
Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations.
11