Loading...
HomeMy WebLinkAbout17212 51st Ave Ne Ste104_BLD6219_2025 Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551 Page 1 of 1 Permit Number: Permit Type: Address/Parcel: Completed (Month/Year): Land Use ˆ Notice of Decision ˆ Staff Report ˆ Application ˆ Narrative ˆ Legal Description ˆ Vicinity Map ˆ Site Plan ˆ Landscape Plan ˆ Complete Streets Checklist ˆ Traffic Impact Analysis ˆ Snohomish County Traffic Mitigation Offer ˆ WSDOT Traffic Offer Form ˆ Tree Survey ˆ Stormwater Drainage Report ˆ Geotech Report ˆ Critical Area Evaluation Form ˆ SEPA Checklist ˆ Public Notice Material ˆ Noticing and Related Documents ˆ Water / Sewer Availability Certificate ˆ Unanticipated Discovery Plan Form ˆ Aerial Photo of Site ˆ Proposed Building Materials ˆ Lighting Plans and Lighting Cut Sheets ˆ Color Elevations ˆ Design Matrix ˆ Plat Map ˆ Title Report ˆ Lot Closures ˆ Preliminary Civil Plans ˆ Archaeological Survey o Confidential Documents. Contact the City to obtain. ˆ Topography (Existing Conditions) ˆ CC&R’s ˆ Deeds / Easements / Conveyances /Dedications ˆ Developer’s Agreement ˆ Recorded Copies ˆ Bonding or Assignment of Funds o Confidential Documents. Contact the City to obtain. ˆ Letters and Project Documents ˆ Other: Civil ˆ Issued Permit ˆ Application ˆ Other Applications ˆ Construction Calculation Worksheet ˆ Approved Plans ˆ Review Comment Form ˆ Letters and Project Documents ˆ Other Agency Permits ˆ Reports: o Drainage Report Pg: o Stormwater Pg: o Geotech Pg: o All Other Reports ˆ SEPA and Noticing Materials ˆ Inspections ˆ As-Builts ˆ Other: Building ˆ Issued Permit ˆ Application ˆ Additional Applications ˆ Approved Plans ˆ Site Plan ˆ Letters and Project Documents ˆ Calculations ˆ Project Specification Manuals ˆ Reports ˆ Certificate of Occupancy ˆ Inspections ˆ Other: BLD6219 Fire Alarm 17212 51st Ave Ne Ste 104 December 2024 ✔ ✔ ✔ ✔ SK-PS6 / SK-PS10 6 Amp and 10 Amp, 24 Volt Power Supplies The PS Series is a remote power supply line from Silent Knight and is a direct replacement for the 5495/5499. The SK-PS6 is a 6 amp and the SK-PS10 is a 10 amp, remote power supply with battery charger that may be connected to any 12 or 24 volt fire alarm control panel (FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs (notification appliance circuits) configured as either Class B or Class A (requires the ZNAC-PS option card) with multiple sync protocol options. The PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door holders, and other fire alarm system peripherals. The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. FEATURES AND BENEFITS • Up to five (6 amp model) or seven (10 amp model) independently-configurable, power- limited output circuits for: –Class B and/or Class A NACs –Class B and/or Class A resettable or non- resettable 24V auxiliary power –door holder power • Converts from Class B to Class A wiring without losing any outputs using the ZNAC- PS converter card (sold separately) • Optimal for powering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated power • Optional addressable control, monitor, and relay modules and power-supervision relay (EOLR-1) • Configurable for ANSI® Temporal 3 or Temporal 4 coded output • UL-Listed NAC synchronization using System Sensor®, Wheelock®, Gentex®, or AMSECO® appliances • Synchronization can be triggered from FACP NAC/remote sync outputs, cascaded power supply, or a control module, single or multi, which may be housed within the power supply cabinet • Ability to cascade up to four power supplies • Two (6 amp model) or three (10 amp model) fully-isolated input/control circuits which can be programmed to any output • Two Form C normally-closed trouble relays for AC Trouble and General Trouble • 6 or 10 amp full load output, respectively, with 3 A maximum/circuit • Individual NAC power and trouble LEDs for diagnostic efficiency • Trouble history mode for diagnostic support • Wide range end-of-line supervision value (normal: 2-27K ohms) • Selectable earth fault detection (enable or disable) • AC trouble report delay timer • Completely configurable via onboard DIP switches, no extra software required • Self-contained in compact, locking cabinet constructed of heavy gauge steel with a corrosion-resistant powder coat chip and scratch-resistant finish • Cabinet designed with ten double knockouts and a removable door for ease of installation and wiring • Includes integral battery charger capable of charging up to 33 AH batteries • Cabinet can house two 7 AH or 18 AH batteries • Battery charger may be disabled via DIP switch for applications requiring larger batteries and external battery charger • Removable terminal blocks accommodate up to 12 AWG (3.1mm2) wire • Works with any UL 864 FACP which utilizes an industry-standard reverse-polarity notification circuit The PS Series are independently configurable power supplies, allowing you to pair any input with any output, and feature LED diagnostics for troubleshooting. Page 2 of 3 — SK-61095:C • 3/10/2021 ORDERING INFORMATION SK-PS6: 6.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, red SK-PS10: 10.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, red ZNAC-PS: Optional Class A converter card, sold separately SK-CONTROL: Addressable Control Module for one Class B or Class A zone of supervised, polarized Notification Appliances. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. SK-RELAY: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch SK-MONITOR: Addressable Monitor Module for one zone of normally open dry-contact initiating devices. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Class B or Class A SK-MONITOR-2: Dual Monitor Module. Same as SK-MONITOR except it provides two inputs for Class B wiring only SK-RELAYMON-2: Provides two monitored inputs and two Form-C relays. Functions in Class B wiring only SK-CONTROL-6: Six-circuit supervised control module SK-RELAY-6: Six Form-C relay control module EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power BAT-1270-BP: Battery, 12 volt, 7.0 AH, 5-pack (two required) BAT-12180-BP: Battery, 12 volt, 18AH, 2-pack BAT-12330: Battery, 12 volt, 33AH SEISKIT-MULTI-1: Seismic kit for the PS Series. Includes bracket and hardware for two 7AH or two 18AH batteries. SK-PS6 / SK-PS10 TECHNICAL SPECIFICATIONS SK-61095 | C | 03/21 ©2021 Honeywell International Inc. Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.silentknight.com Silent Knight® and System Sensor® are registered trademarks of Honeywell International, Inc. Wheelock® is a registered trademark of Cooper Technologies Company. Gentex® is a registered trademark of Gentex Corporation. AMSECO® is a registered trademark of Potter Electric Signal Company, LLC. ANSI® is a registered trademark of the American National Standards Institute, Inc. ©2021 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of origin: USA PRIMARY (AC) POWER SK-PS6: 120 VAC, 50/60 Hz, 5.0A maximum SK-PS10: 120VAC, 50/60 Hz, 6.2 A maximum Wire Size: #12-14 AWG with 600 V insulation COMMAND INPUT CIRCUIT Trigger Input Voltage: 9 to 32 VDC Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 - 16 V) RELAY CIRCUITS Trouble Contact Rating: 4 A at 24 VDC OUTPUT CIRCUITS • 24 VDC filtered • SK-PS6: TB8-TB9 – 1A Regulated, 3A special applications; TB10-TB12 – 0.3A Regulated, 3A special applications • SK-PS10: TB8-TB11 – 1.5A Regulated, 3A special applications; TB12-TB14 – 0.3A Regulated, 3A special applications • 6.0 A (SK-PS6) or 10.0 (SK-PS10) maximum total continuous current for all outputs SECONDARY POWER (BATTERY) CHARGING CIRCUIT • Supports lead-acid batteries only • Float-charge voltage: 27.6 VDC • Maximum current charge: 1.5 A • Maximum battery capacity: 18 AH (inside cabinet) • Maximum battery charging capacity: 33 AH (external cabinet) PHYSICAL Dimensions: 20.0”H x 14.5”W x 3.5”D (cm: 50.8H x 36.83W x 8.9D) Weight: with two 7Ah batteries is 24 pounds (10.9 kg), with two 18 AH batteries is 39 pounds (17.7 kg) STANDARDS AND CODES The SK-PS complies with the following standards: NFPA 72: National Fire Alarm Code UL 864: Standard for Control Units for Fire Alarm Systems (NAC expander mode) UL 1481: Power Supplies for Fire Alarm Systems AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S3511 CSFM: 7315-0559:0522 FDNY Approved FM Approved 7300-1653:0525 7135-1653:0503 7135-1653:0526 Horn Strobes and Strobes: S5512, S4011 3057072 FM23FPUS0195 Horns: S4011 Agency Listings AVDS916-01 • 10/03/2023 • Page 1 Features • LED technology provides lower current draw • Digital Voltage Meter (DVM) diagnostic test points for Horn Strobes and Strobes • Common aesthetics across the L-Series platform • Standard and compact sizes • Tamper-resistant construction • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Rotary switches for candela, tone and volume selections • Mounting plate provides plug-in design for easier installation and shorting springs to check wiring continuity • Electrically compatible with legacy SpectrAlert, SpectrAlert Advance and L-series devices • Synchronization through use of UL approved power supplies that support System Sensor Sync protocol or System Sensor MDL3 Sync Module • Horns, Strobes and Horn Strobes listed for wall or ceiling use The System Sensor L-Series and L-Series with LED platform offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draw and modern aesthetics. LED lighting technology offers significantly lower current draw compared to older Xenon bulbs across a full candela range. This improves design flexibility for notification appliance circuits (NACs) while also reducing power supply requirements allowing for simpler and lower cost installations. Flexible design options meet virtually any application requirement: wall or ceiling mount, standard or compact sizes, red or white color choices, bezel kits for alternate markings and languages, and LED color lenses for distinctive visual signaling. In addition, installers can easily adapt devices using field selectable candela, tone and volume settings using rotary switches. The L-Series and L-Series with LED line is developed to simplify installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. The universal mounting plate includes an onboard shorting spring, so installers can test wiring continuity before the device is installed. In addition, the System Sensor L-Series with LED notification appliances offer a new diagnostic test point feature that allows you to measure device voltage with a digital voltage meter (DVM) without removing the appliance from the wall or ceiling. The DVM test points are discreetly located on the face of the notification appliance which enable faster troubleshooting and end of line (EOL) voltage checks while greatly reducing the risk of misplacing or damaging appliances during troubleshooting. L-Series and L-Series with LED Indoor Selectable Horns, Strobes and Horn Strobes System Sensor L-Series and L-Series with LED audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Horns: S4011 AVDS916-01 • 10/03/2023 • Page 2 L-Series and L-Series with LED Specifications Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage, LED Strobes and Horn Strobes Regulated 24 VDC Nominal Voltage, Horns Regulated 12 VDC or regulated 24 DC/FWR Operating Voltage Range, LED Strobes and Horn Strobes 16 to 33 V (24 V nominal) Operating Voltage Range, Horns 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG UL/ULC Maxmimum Strobe Current Draw (mA) Candela Rating 16–33 Volts Wall Ceiling Candela Range 15 18 18 30 22 22 75 70 70 95 75 75 110 85 — 115 —90 135 105 — 150 —110 177 —115 185 120 — UL/ULC Current Draw Data, Horn Tones, and Sound Output Data UL/ULC Maximum Horn Strobe Current Draw (mA) and Sound Output (dBA) Switch Pos.Sound Pattern Volume Setting Current Draw (mA RMS), Horn Strobe, Candela Range (15-185 cd) Sound Output (dBA) 16-33 Volts 16-33V 15cd 30cd 75cd 95cd 110cd WALL 115cd CEILING 135cd WALL 150cd CEILING 177cd CEILING 185cd WALL DC 1 Temporal 3 High 35 38 87 92 94 120 189 189 190 190 87 2 Temporal 3 Low 35 38 87 92 94 120 135 135 145 145 79 3 Non-Temporal High 50 52 87 92 94 120 127 127 135 135 87 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 79 5 3.1KHz Temporal 3 High 35 38 87 89 91 115 155 155 165 165 86 6 3.1KHz Temporal 3 Low 35 38 87 89 91 115 128 130 135 135 80 7 3.1KHz Non-Temporal High 40 42 87 89 91 115 125 125 135 135 86 8 3.1KHz Non-Temporal Low 35 38 87 89 91 115 120 120 130 130 80 UL/ULC Maxmimum Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 AVDS916-01 • 10/03/2023 • Page 3 L-Series with LED Dimensions: Wall-Mounted Equipment Compact Strobe, Horn Strobe for Wall Compact Horn Strobes, Horn Strobes for Walls Surface Mount Back Box for Walls ( SBBRL/SBBWL) 4.82" (12.24 cm)1.85" (4.69 cm) 5.78" 1.55" (3.9 cm) 3.57" (9.1 cm) 5.38" (13.7 cm) Compact Surface Mount Back Box for Walls (SBBGRL, SBBGWL) 4.7" 119 mm 5.67" 144 mm 1.25" 32 mm 3.46" 88 mm 1.25" 32 mm 5.27" 133.9 mm 4.7" 119 mm 5.67" 144 mm 1.25" (53 mm) 3.46" 88 mm 5.27" 1.25" (31.8 mm) (53 mm) Horn A0549-00A0613-00 A0554-01 A0617-00 A0557-00A0547-00 Strobes and Horn Strobes for Ceilings Surface Mount Back Box for Ceilings (SBBCRL, SBCWL) 6.83" diam. (173.5 mm) 1.25" (52.6 mm) 6.92" diam. (175.77 mm) 2.5" (64 mm) A0608-00 A0546-00 L-Series with LED Dimensions: Ceiling-Mounted Equipment System Sensor® is a registered trademark of Honeywell International, Inc. 3825 Ohio Avenue • St. Charles, IL 60174 USA Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com 3333 Unity Drive, Mississauga, ON L5L 3S6 Canada Phone: 800-SENSOR2 • Fax: 905-812-0771 www.systemsensor.ca ©2023 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS916-01 • 10/03/2023 Model Description L-Series with LED Horn Strobes P2RLED 2-Wire, Horn Strobe, Wall, Red P2RLED-B 2-Wire, Horn Strobe, Wall, Red, Bilingual P2WLED 2-Wire, Horn Strobe, Wall, White P2WLED-B 2-Wire, Horn Strobe, Wall, White, Bilingual P2GRLED 2-Wire, Compact Horn Strobe, Wall, Red P2GRLED-B 2-Wire, Compact Horn Strobe, Wall, Red, Bilingual P2GWLED 2-Wire, Compact Horn Strobe, Wall, White P2GWLED-B 2-Wire, Compact Horn Strobe, Wall, White, Bilingual P2RLED-P 2-Wire, Horn Strobe, Wall, Red, Plain P2WLED-P 2-Wire, Horn Strobe, Wall, White, Plain P2RLED-SP 2-Wire, Horn Strobe, Wall, Red, FUEGO P2WLED-SP 2-Wire, Horn Strobe, Wall, White, FUEGO PC2RLED 2-Wire, Horn Strobe, Ceiling, Red PC2RLED-B 2-Wire, Horn Strobe, Ceiling, Red, Bilingual PC2WLED 2-Wire, Horn Strobe, Ceiling, White PC2WLED-B 2-Wire, Horn Strobe, Ceiling, White, Bilingual L-Series with LED Strobes SRLED Strobe, Wall, Red SRLED-B Strobe, Wall, Red, Bilingual SWLED Strobe, Wall, White SWLED-B Strobe, Wall, White, Bilingual SGRLED Strobe, Compact, Wall, Red SGRLED-B Strobe, Compact, Wall, Red, Bilingual SGWLED Strobe, Compact, Wall, White SGWLED-B Strobe, Compact, Wall, White, Bilingual SRLED-P Strobe, Wall, Red, Plain SWLED-P Strobe, Wall, White, Plain SRLED-SP Strobe, Wall, Red, FUEGO SWLED-CLR- ALERT Strobe, Wall, White, ALERT SWLED-ALERT Strobe, Wall, White, ALERT, Amber Lens SCRLED Strobe, Ceiling, Red SCRLED-B Strobe, Ceiling, Red, Bilingual SCRLED-P Strobe, Ceiling, White, Plain SCWLED Strobe, Ceiling, White SCWLED-B Strobe, Ceiling, White, Bilingual SCWLED-P Strobe, Ceiling, White, Plain SCWLED-CLR- ALERT Strobe, Ceiling, White, ALERT L-Series Horns HRL*Horn, Red HRLA*Horn, Red, Plain, ULC HWL*Horn, White HWLA*Horn, White, Plain, ULC HGRL*Compact Horn, Red HGRLA*Compact Horn, Red, Plain, ULC HGWL*Compact Horn, White HGWLA*Compact Horn, White, Plain, ULC L-Series with LED: Ordering Information Model Description LED Lenses LENS-A3 Lens LED Amber Wall/Ceiling LENS-B3 Lens LED Blue Wall/Ceiling LENS-G3 Lens LED Green Wall/Ceiling LENS-R3 Lens LED Red Wall/Ceiling Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White TRC-2 Universal Ceiling Trim Ring, Red TRC-2W Universal Ceiling Trim Ring, White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White Bezels† BZR Wall Red Bezel Kit BZW Wall White Bezel Kit BZGR Compact Wall Red Bezel Kit BZGW Compact Wall White Bezel Kit BZRC Horn Strobe Ceiling Red Bezel Kit BZWC Horn Strobe Ceiling White Bezel Kit Notes for L-Series With LED Horn Strobes and Strobes: All -P models have a plain housing (no “FIRE” marking on cover). All -SP models have “FUEGO” marking on cover. All -ALERT models have “ALERT” marking on cover. All -B models have “FIRE/FEU” marking on cover for use in Canadian applications. Amber lenses are not for use in Canadian applications Notes for L-Series Horns: *Horn-only models are listed for wall or ceiling use. Notes for Bezels: †Each bezel pack ships in a package of 5. Add one of the following extensions for print/language options: -F (FIRE), -AL (ALERT), -EV (EVAC), -AG (AGENT), -P (Plain), -FR (FEU), -PG (FOGO), -SP (FUEGO), -SPE (FUEGO/FIRE). SK-PHOTO-W SERIES Addressable Photoelectric Smoke Detectors The Silent Knight® SK-PHOTO-W Series feature a modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The SK-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the SK-PHOTO Series detectors. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector’s address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DNR Series duct detector housings. FEATURES AND BENEFITS • Designed to meet UL 1268 7th Edition • Sleek and stylish contemporary design • Stable communication technique with noise immunity • Addressable by device • Rotary, decimal addressing (Refer to the Silent Knight panel manuals for device capacity) • Two-wire SLC connection • LEDs blink every time the unit is polled • 360°-field viewing angle of the visual alarm indicators (two bi-color LEDs); LEDs blink green in Normal condition and turn on steady red in Alarm • Integral communications and built-in device-type identification • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Walk test with address display (an address of 121 will blink the detector LED 12- (pause)-1) • Low standby current • Built-in tamper-resistant feature • Designed for direct-surface or electrical- box mounting • Sealed against back pressure • Plugs into separate base for ease of installation and maintenance • Expanded color options • SEMS screws for wiring of the separate base • Optional remote, single-gang LED accessory • Optional sounder, relay, and isolator bases Page 2 of 3 — 351634:B • 7/1/2019 INSTALLATION The SK-PHOTO-W Series plug-in intelligent thermal detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see SK-61045. Note: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring. Note: When using relay or sounder bases, consult the SK-ISO installation sheet I56-3627 for device limitations between isolator modules and isolator bases. OPERATION Each SK-PHOTO-W Series detector uses one of the panel’s addresses (total limit is panel dependent) on the Signaling Line Circuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The SK-PHOTO-W Series offers features and performance that represent the latest in smoke detector technology. PRODUCT LINE INFORMATION Note: “-IV” suffix indicates ivory color. SK-PHOTO-W: White, low-profile photoelectric sensor SK-PHOTO-T-W: White, same as SK-PHOTO-W but includes a built-in 135°F (57°C) fixed-temperature thermal device SK-PHOTO-R-W: White, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW B300-6: White, standard flanged low-profile mounting base B300-6-BP: Bulk pack of B300-6, package contains 10 B300-6-IV: Ivory, standard flanged low-profile mounting base B501-WHITE: White, standard European flangeless mounting base B501-BL: Black, standard European flangeless mounting base B501-IV: Ivory, standard European flangeless mounting base B501-WHITE-BP: Bulk pack of B501-WHITE, contains 10 B200S-WH: White, Intelligent, programmable sounder base B200S-IV: Ivory, Intelligent, programmable sounder base B200SR-WH: White, Intelligent sounder base for retrofit applications B200SR-IV: Ivory, Intelligent sounder base for retrofit applications B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications B224RB-WH: White, plug-in System Sensor® relay base B224RB-IV: Ivory, plug-in System Sensor relay base B224BI-WH: White, plug-in System Sensor isolator detector base B224BI-IV: Ivory, plug-in System Sensor isolator detector base ACCESSORIES TR300: White, replacement flange for B210LP or B300-6 bases TR300-IV: Ivory, replacement flange for B210LP or B300-6 bases RA100Z(A): Remote 3 – 32 VDC LED annunciator, mounts to a U.S. single-gang electrical box, for use with B501 and B300-6 bases only M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: White, detector color kit, pack of 10 CK300-IV: Ivory, detector color kit, pack of 10 CK300-BL: Black, detector color kit, pack of 10 SK-PHOTO-W SERIES TECHNICAL SPECIFICATIONS 351634 | B | 07/19 ©2019 Honeywell International Inc. Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.silentknight.com Silent Knight® and System Sensor® are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of origin: Mexico PHYSICAL/ENVIRONMENTAL Sensitivity: -UL Applications: 0.5% to 4.0% per foot obscuration. -ULC Applications: 0.5% to 3.5% per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter - B300-6: 6.1" (15.6 cm) diameter - B501: 4" (10.2 cm) diameter For a complete list of detector bases, see SK-61045. Shipping weight: 3.4 oz. (95 g) Operating temperature range: • SK-PHOTO-W: 32°F to 122°F (0°C to 50°C) • SK-PHOTO-T-W: 32°F to 100°F(0°C to 38°C) • SK-PHOTO-R-W installed in a DNR/DNRW: -4°F to 158°F (-20°C to 70°C) UL/ULC Listed Velocity Range: 0-4000 ft/ min. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10% – 93% non- condensing Thermal ratings: fixed-temperature set point 135°F (57°C), rate-of-rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak Standby current (max. avg.): 200µA @ 24 VDC (one communication every 5 seconds with LED enabled) Max current: 4.5 mA @ 24 VDC (“ON”) DETECTOR SPACING AND APPLICATIONS Silent Knight recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document A05-1003, is available at www.systemsensor.com. AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document.In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL Listed: S6173 • FM Approved •CSFM: 7272-0559:0512