Loading...
HomeMy WebLinkAbout20910 67th Ave Ne_BLD6270_2025 Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551 Page 1 of 1 Permit Number: Permit Type: Address/Parcel: Completed (Month/Year): Land Use ˆ Notice of Decision ˆ Staff Report ˆ Application ˆ Narrative ˆ Legal Description ˆ Vicinity Map ˆ Site Plan ˆ Landscape Plan ˆ Complete Streets Checklist ˆ Traffic Impact Analysis ˆ Snohomish County Traffic Mitigation Offer ˆ WSDOT Traffic Offer Form ˆ Tree Survey ˆ Stormwater Drainage Report ˆ Geotech Report ˆ Critical Area Evaluation Form ˆ SEPA Checklist ˆ Public Notice Material ˆ Noticing and Related Documents ˆ Water / Sewer Availability Certificate ˆ Unanticipated Discovery Plan Form ˆ Aerial Photo of Site ˆ Proposed Building Materials ˆ Lighting Plans and Lighting Cut Sheets ˆ Color Elevations ˆ Design Matrix ˆ Plat Map ˆ Title Report ˆ Lot Closures ˆ Preliminary Civil Plans ˆ Archaeological Survey o Confidential Documents. Contact the City to obtain. ˆ Topography (Existing Conditions) ˆ CC&R’s ˆ Deeds / Easements / Conveyances /Dedications ˆ Developer’s Agreement ˆ Recorded Copies ˆ Bonding or Assignment of Funds o Confidential Documents. Contact the City to obtain. ˆ Letters and Project Documents ˆ Other: Civil ˆ Issued Permit ˆ Application ˆ Other Applications ˆ Construction Calculation Worksheet ˆ Approved Plans ˆ Review Comment Form ˆ Letters and Project Documents ˆ Other Agency Permits ˆ Reports: o Drainage Report Pg: o Stormwater Pg: o Geotech Pg: o All Other Reports ˆ SEPA and Noticing Materials ˆ Inspections ˆ As-Builts ˆ Other: Building ˆ Issued Permit ˆ Application ˆ Additional Applications ˆ Approved Plans ˆ Site Plan ˆ Letters and Project Documents ˆ Calculations ˆ Project Specification Manuals ˆ Reports ˆ Certificate of Occupancy ˆ Inspections ˆ Other: BLD6270 Residential Plumbing 20910 67th Ave Ne December 2024 ✔ ✔ ✔ RESIDENTIAL PLUMBING APPLICATION Community and Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 REV03.2022 Page 1 of 2 This application is for new, repaired, altered or replaced plumbing installation for existing residences. Please fill out all pages of this application and include all information. The City of Arlington does not require a permit to stop leaks or clear stoppages, unless the piping is repaired, altered or replaced. • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) • Cross-Connection-Control may be required PLUMBING PERMIT FEES (per fixture) Additional Plan Review fees x $ 75.00 = Alteration/repair piping x $ 15.00 = Backflow Assembly x $25.00 = Base Plumbing Fee 1 x $ 25.00 = $25.00 Bath/Shower Combo x $ 15.00 = Building Main Waste x $ 25.00 = Clothes Washer x $ 15.00 = Dishwasher x $ 15.00 = Type of Permit:  New Installation  Addition  Alteration  Repair Property Address: Project Valuation: Lot #: Parcel ID No.: Preferred Contact: Owner Contractor Project Description: Owner Name: Home No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Contractor Name: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: Proposed Interior Water Piping Size:  ½”  ⅝”  ¾”  1” Proposed Interior Piping Material:  CPVC  Brass  Copper  PEX-AL-PEX  PEX  Galvanized Steel  Other Proposed Exterior Water Piping Size:  ½”  ⅝”  ¾”  1”  1½”  2” Proposed Exterior Piping Material:  PVC  PE  Copper  PEX-AL-PEX  PEX-AL-PE  PEX  Other Proposed Drain-Waste-Vent (DWV) Material: Schedule 40 ABS DWV Copper Galvanized Steel Cast Iron Schedule 40 PVC DWV Brass Other Proposed Drain-Waste-Vent (DWV) Piping Size:  ½”  ⅝”  ¾”  1”  1½”  2”  3” 4” Water Residential Electric Professional Prestige ProTerra Hybrid Electric Heat Pump Water Heaters 07/24 WP FORM NO. HP-400-NO SO INTEGR AT ED HOME COMFOR Professional Prestige® ProTerra® Hybrid Electric Heat Pump is the most efficient water heater available Professional Prestige ProTerra Hybrid Electric Heat Pump 40, 50, 65 and 80-Gallon Capacities 208-240 Volt / 1 PH 30 and 15 Amp Electric LEED Points = 3 Efficiency • Up to 4.07 UEF reduces operating cost • ENERGY STAR® certified • Title 24 Compliant (JA13 Ready) Performance • Delivers hot water faster than most standard electric water heaters – 60-87 gallons first-hour delivery, depending on model • Ambient operating range: 37-145° F is widest in class, offering more heat pump operation annually; designed to meet Northern Climate Spec (Tier 4) • Quiet Operation Easy Installation • Universal top and side water connections • Quick access to electrical junction box • Duct ready design • Easily replaces a standard electric water heater Integration • Electronic control for easy temperature adjustment and mode management • Audible alarm for service alerts • Built-in Wi-Fi powered by EcoNet®* and free mobile app gives users control over water heater, allowing for customizable temperature, vacation settings, energy savings and system monitoring at home or away • Demand Response Ready with built-in EcoPort™ (CTA-2045 Port) • Easily add leak detection and prevention with the leak sensor and shut-off valve kit (part# SP21265A sold separately) Operation Modes • Energy Saver • Heat Pump • High Demand • Electric • Vacation/Away: 2-28 days (or placed on hold indefinitely) Plus… • Premium grade anode rod extends the life of the tank • Dip tube diffuser reduces sediment improving efficiency and tank life • 3/4" NPT water inlet and outlet; 3/4" condensate drain connections • Incoloy stainless steel resistor elements • Dry-fire protection • Easy access, top mounted washable air filter • 2" Non-CFC foam insulation • Enhanced flow brass drain valve • Temperature and pressure relief valve installed • Design certified to NSF/ANSI 372 (Lead Content) Warranty • 10-Year limited tank and parts warranty See Residential Warranty Certificate for complete information Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria. See specifications chart on next page. *Wi-Fi broadband internet connection required. New! Top Connections and Duct Ready Design Professional Prestige® ProTerra Hybrid Electric Heat Pump Specifications 2 Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements. All units have integrated Wi-Fi control board. DESCRIPTION ENERGY INFO FEATURES SHIPPING WEIGHTS NOMINAL GALLON CAPACITY RATED GALLON CAPACITY MODEL NUMBER MODEL VARIANT ELECTRIC BREAKER SIZE UNIFORM ENERGY FACTOR (UEF) COMPRESSOR BTU/H UEF FIRST HR. RATING G.P.H. RECOVERY IN G.P.H 90° F RISE ELEMENT WATTAGE TOTAL UNIT WATTAGE MAX AMPS UNIT WT. (LBS) APPROX. SHIP WT. (LBS.) ProTerra 30 Amp 40 36 PROPH40 T2 RH400-30 702303 30 3.83 4,200 60 27 4,500 5,000 21 166 184 50 45 PROPH50 T2 RH400-30 702300 30 3.88 4,200 67 27 4,500 5,000 21 185 203 65 59 PROPH65 T2 RH400-30 702302 30 4.05 4,200 76.6 27 4,500 5,000 21 245 289 80 72 PROPH80 T2 RH400-30 702344 30 4.07 4,200 87 27 4,500 5,000 21 261 306 ProTerra 15 Amp 40 36 PROPH40 T2 RH400-15 702293 15 3.45 4,200 46 16 2,250 2,750 12 166 184 50 45 PROPH50 T2 RH400-15 702297 15 3.75 4,200 52 16 2,250 2,750 12 185 203 65 59 PROPH65 T2 RH400-15 702292 15 3.55 4,200 54 16 2,250 2,750 12 245 289 80 72 PROPH80 T2 RH400-15 702295 15 3.70 4,200 67 16 2,250 2,750 12 261 306 DESCRIPTION DIMENSIONS (SHOWN IN INCHES) NOMINAL GALLON CAPACITY MODEL NUMBER A B C D E F G H I J K 40 PROPH40 62-5/16 20-1/4 47 3-5/8 39-5/8 25-3/8 20-1/2 78-7/8 20-1/4 21-3/4 64-15/16 50 PROPH50 61-3/4 22-1/4 47 3-5/8 39-5/8 27-3/8 22-1/2 78-5/8 22-1/4 21-3/4 64-3/8 65 PROPH65 64-3/16 24-1/4 49 3-7/8 42-3/8 29-1/2 24-5/8 81-1/8 24-1/4 25-13/16 66-13/16 80 PROPH80 74-3/16 24-1/4 59 3-7/8 42-3/8 29-1/2 24-5/8 91 24-1/4 25-11/16 76-13/16 A C E DD B F G 2” Clearance Needed for T&P Release H I J K Room size: Larger than 700 ft3 (e.g. 7' x 10' x 10'). Requirements: No additional ventilation needed. Heater: Not Ducted 24” 12” Max Air exhaust Door .75” Room size: Any size room Requirements: No additional ventilation needed. Heater: Ducted with inlet AND outlet ductRoom size: Any size room Requirements: Air gap under door equal to 18 in2 (0.75” clearance) Heater: Ducted with inlet OR outlet duct Room size: Smaller than 700 ft3 (e.g. 7' x 10' x 10'). Requirements: Full louvered door OR two louvers top and bottom. See below. Heater: Not Ducted 24”.75” Room: Small Closet Requirements: * Air gap under door equal to 18 in2 (0.75” clearance). * Louver must be located the same height on door as the air exhaust on heater. * Heater air exhaust must be positioned towards louver within one foot of door. Heater: Not ducted 3 Hybrid Electric Heat Pump Water Heater Installation Guidelines to Provide Optimal Efficiency NOTE: Heat pump water heater will operate in rooms less than 700 ft3 down to 450 ft3 but at reduced energy efficiency and reduced performance output. Reduced energy efficiency and performance has not been evaluated by Rheem Manufacturing and not recommended for optimal performance of the unit. When unit is operated in a small enclosure, a door or wall with a minimum of 2.3 sq ft of louvers is recommended to provide proper air changes for unit function. Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 • www.rheem.com Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 • www.rheem.ca 07/24 WP FORM NO. HP-400-NO SO INTEGR AT ED HOME COMFOR In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. 4 Hybrid Electric Heat Pump Accessories List Earthquake Isolation KitLeak Sensor 7" Diameter UL Certified Termination Kit 8" Collar for Flex Venting Vibration Isolation KitShutoff Valve 6" Diameter UL Certified Termination Kit 25' Flexible 8" Diameter Duct Kit 8" Diameter UL Certified Termination Kit 5" Diameter UL Certified Termination Kit 8" Rigid Elbow Duct Kit Leak Sensor & Shutoff Valve Kit UPGRADE KIT (for ProTerra models without LeakGuard only) – Add leak detector and shuttoff valve to protect from water damage PART NUMBER DESCRIPTION USE FOR AP19134 Leak Sensor Automatic detection of internal and external leaks AS50618A Shutoff Valve Automatic shut off of water supply to unit SP20882 Earthquake Isolation Kit Installations in seismic regions SP20883 Vibration Isolation Kit Installation on non-concrete floors SP20884 8" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 8" diameter SP20885 7" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 7" diameter SP20886 6" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 6" diameter SP20887 5" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 5" diameter SP20888 8" Collar for Flex Venting Exhaust only to the outside ducting configuration (no inlet duct) SP20889 25' Flexible 8" Diameter Duct Kit For up to 25' of ducting SP20890 8" Rigid Elbow Duct Kit Installation in tight places where space needs to be minimized UPGRADE KIT SP21265A Kit - Automatically Shutoff Valve Assembly Add leak detector, shutoff valve and S.O.V. extension harness for top connection setup Water Residential Electric Professional Prestige ProTerra Hybrid Electric Heat Pump Water Heaters