HomeMy WebLinkAbout20910 67th Ave Ne_BLD6270_2025
Permit Packet Coversheet
Community and Economic Development
City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551
Page 1 of 1
Permit Number: Permit Type:
Address/Parcel: Completed (Month/Year):
Land Use
Notice of Decision
Staff Report
Application
Narrative
Legal Description
Vicinity Map
Site Plan
Landscape Plan
Complete Streets Checklist
Traffic Impact Analysis
Snohomish County Traffic Mitigation Offer
WSDOT Traffic Offer Form
Tree Survey
Stormwater Drainage Report
Geotech Report
Critical Area Evaluation Form
SEPA Checklist
Public Notice Material
Noticing and Related Documents
Water / Sewer Availability Certificate
Unanticipated Discovery Plan Form
Aerial Photo of Site
Proposed Building Materials
Lighting Plans and Lighting Cut Sheets
Color Elevations
Design Matrix
Plat Map
Title Report
Lot Closures
Preliminary Civil Plans
Archaeological Survey
o Confidential Documents. Contact the
City to obtain.
Topography (Existing Conditions)
CC&R’s
Deeds / Easements / Conveyances
/Dedications
Developer’s Agreement
Recorded Copies
Bonding or Assignment of Funds
o Confidential Documents. Contact the
City to obtain.
Letters and Project Documents
Other:
Civil
Issued Permit
Application
Other Applications
Construction Calculation Worksheet
Approved Plans
Review Comment Form
Letters and Project Documents
Other Agency Permits
Reports:
o Drainage Report Pg:
o Stormwater Pg:
o Geotech Pg:
o All Other Reports
SEPA and Noticing Materials
Inspections
As-Builts
Other:
Building
Issued Permit
Application
Additional Applications
Approved Plans
Site Plan
Letters and Project Documents
Calculations
Project Specification Manuals
Reports
Certificate of Occupancy
Inspections
Other:
BLD6270 Residential Plumbing
20910 67th Ave Ne December 2024
✔
✔
✔
RESIDENTIAL PLUMBING APPLICATION
Community and Economic Development
City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551
REV03.2022 Page 1 of 2
This application is for new, repaired, altered or replaced plumbing installation for existing residences. Please fill out all pages of this application and include all information. The City of Arlington does not require a permit to stop leaks or clear stoppages, unless the piping is repaired, altered or replaced.
• All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019
• All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV)
• Cross-Connection-Control may be required
PLUMBING PERMIT FEES (per fixture)
Additional Plan Review fees x $ 75.00 = Alteration/repair piping x $ 15.00 = Backflow Assembly x $25.00 = Base Plumbing Fee 1 x $ 25.00 = $25.00 Bath/Shower Combo x $ 15.00 = Building Main Waste x $ 25.00 = Clothes Washer x $ 15.00 = Dishwasher x $ 15.00 =
Type of Permit: New Installation Addition Alteration Repair Property Address: Project Valuation: Lot #: Parcel ID No.: Preferred Contact: Owner Contractor Project Description: Owner Name: Home No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Contractor Name: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date:
Proposed Interior Water Piping Size: ½” ⅝” ¾” 1” Proposed Interior Piping Material: CPVC Brass Copper PEX-AL-PEX PEX Galvanized Steel Other Proposed Exterior Water Piping Size: ½” ⅝” ¾” 1” 1½” 2” Proposed Exterior Piping Material: PVC PE Copper PEX-AL-PEX PEX-AL-PE PEX Other Proposed Drain-Waste-Vent (DWV) Material: Schedule 40 ABS DWV Copper Galvanized Steel Cast Iron Schedule 40 PVC DWV Brass Other Proposed Drain-Waste-Vent (DWV) Piping Size: ½” ⅝” ¾” 1” 1½” 2” 3” 4”
Water
Residential Electric
Professional Prestige ProTerra
Hybrid Electric Heat Pump Water Heaters
07/24 WP FORM NO. HP-400-NO SO
INTEGR AT ED HOME COMFOR
Professional Prestige® ProTerra® Hybrid
Electric Heat Pump is the most efficient
water heater available
Professional Prestige
ProTerra Hybrid Electric
Heat Pump
40, 50, 65 and 80-Gallon
Capacities
208-240 Volt / 1 PH
30 and 15 Amp
Electric
LEED Points = 3
Efficiency
• Up to 4.07 UEF reduces operating
cost
• ENERGY STAR® certified
• Title 24 Compliant (JA13 Ready)
Performance
• Delivers hot water faster than most
standard electric water heaters –
60-87 gallons first-hour delivery,
depending on model
• Ambient operating range: 37-145° F
is widest in class, offering more heat
pump operation annually; designed to
meet Northern Climate Spec (Tier 4)
• Quiet Operation
Easy Installation
• Universal top and side water
connections
• Quick access to electrical junction box
• Duct ready design
• Easily replaces a standard electric
water heater
Integration
• Electronic control for easy temperature
adjustment and mode management
• Audible alarm for service alerts
• Built-in Wi-Fi powered by EcoNet®*
and free mobile app gives users
control over water heater, allowing for
customizable temperature, vacation
settings, energy savings and system
monitoring at home or away
• Demand Response Ready with built-in
EcoPort™ (CTA-2045 Port)
• Easily add leak detection and
prevention with the leak
sensor and shut-off valve kit
(part# SP21265A sold separately)
Operation Modes
• Energy Saver
• Heat Pump
• High Demand
• Electric
• Vacation/Away: 2-28 days (or placed
on hold indefinitely)
Plus…
• Premium grade anode rod extends
the life of the tank
• Dip tube diffuser reduces sediment
improving efficiency and tank life
• 3/4" NPT water inlet and outlet;
3/4" condensate drain connections
• Incoloy stainless steel resistor
elements
• Dry-fire protection
• Easy access, top mounted washable
air filter
• 2" Non-CFC foam insulation
• Enhanced flow brass drain valve
• Temperature and pressure relief valve
installed
• Design certified to NSF/ANSI 372
(Lead Content)
Warranty
• 10-Year limited tank and parts
warranty
See Residential Warranty Certificate for complete
information
Units meet or exceed ANSI requirements and have
been tested according to D.O.E. procedures. Units
meet or exceed the energy efficiency requirements
of NAECA, ASHRAE standard 90, ICC Code and all
state energy efficiency performance criteria.
See specifications chart on next page.
*Wi-Fi broadband internet connection required.
New! Top Connections
and Duct Ready Design
Professional Prestige® ProTerra Hybrid Electric Heat Pump Specifications
2
Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements.
All units have integrated Wi-Fi control board.
DESCRIPTION ENERGY INFO FEATURES SHIPPING WEIGHTS
NOMINAL
GALLON
CAPACITY
RATED
GALLON
CAPACITY
MODEL
NUMBER
MODEL
VARIANT
ELECTRIC
BREAKER
SIZE
UNIFORM
ENERGY FACTOR
(UEF)
COMPRESSOR
BTU/H
UEF
FIRST HR.
RATING
G.P.H.
RECOVERY
IN G.P.H
90° F RISE
ELEMENT
WATTAGE
TOTAL
UNIT
WATTAGE
MAX
AMPS
UNIT
WT.
(LBS)
APPROX.
SHIP WT.
(LBS.)
ProTerra 30 Amp
40 36 PROPH40 T2 RH400-30 702303 30 3.83 4,200 60 27 4,500 5,000 21 166 184
50 45 PROPH50 T2 RH400-30 702300 30 3.88 4,200 67 27 4,500 5,000 21 185 203
65 59 PROPH65 T2 RH400-30 702302 30 4.05 4,200 76.6 27 4,500 5,000 21 245 289
80 72 PROPH80 T2 RH400-30 702344 30 4.07 4,200 87 27 4,500 5,000 21 261 306
ProTerra 15 Amp
40 36 PROPH40 T2 RH400-15 702293 15 3.45 4,200 46 16 2,250 2,750 12 166 184
50 45 PROPH50 T2 RH400-15 702297 15 3.75 4,200 52 16 2,250 2,750 12 185 203
65 59 PROPH65 T2 RH400-15 702292 15 3.55 4,200 54 16 2,250 2,750 12 245 289
80 72 PROPH80 T2 RH400-15 702295 15 3.70 4,200 67 16 2,250 2,750 12 261 306
DESCRIPTION DIMENSIONS (SHOWN IN INCHES)
NOMINAL
GALLON
CAPACITY
MODEL
NUMBER A B C D E F G H I J K
40 PROPH40 62-5/16 20-1/4 47 3-5/8 39-5/8 25-3/8 20-1/2 78-7/8 20-1/4 21-3/4 64-15/16
50 PROPH50 61-3/4 22-1/4 47 3-5/8 39-5/8 27-3/8 22-1/2 78-5/8 22-1/4 21-3/4 64-3/8
65 PROPH65 64-3/16 24-1/4 49 3-7/8 42-3/8 29-1/2 24-5/8 81-1/8 24-1/4 25-13/16 66-13/16
80 PROPH80 74-3/16 24-1/4 59 3-7/8 42-3/8 29-1/2 24-5/8 91 24-1/4 25-11/16 76-13/16
A
C E
DD
B
F
G
2” Clearance Needed
for T&P Release
H
I
J
K
Room size: Larger than 700 ft3 (e.g. 7' x 10' x 10').
Requirements: No additional ventilation needed.
Heater: Not Ducted
24”
12” Max
Air exhaust
Door
.75”
Room size: Any size room
Requirements: No additional ventilation needed.
Heater: Ducted with inlet AND outlet ductRoom size: Any size room
Requirements: Air gap under door equal to 18 in2
(0.75” clearance)
Heater: Ducted with inlet OR outlet duct
Room size: Smaller than 700 ft3 (e.g. 7' x 10' x 10').
Requirements: Full louvered door OR two louvers
top and bottom. See below.
Heater: Not Ducted
24”.75”
Room: Small Closet
Requirements: * Air gap under door equal to 18 in2 (0.75” clearance).
* Louver must be located the same height on door as
the air exhaust on heater.
* Heater air exhaust must be positioned towards louver
within one foot of door.
Heater: Not ducted
3
Hybrid Electric Heat Pump Water Heater Installation Guidelines to Provide
Optimal Efficiency
NOTE: Heat pump water heater will operate in rooms less than 700 ft3 down to 450 ft3 but at reduced energy efficiency and reduced performance output. Reduced energy
efficiency and performance has not been evaluated by Rheem Manufacturing and not recommended for optimal performance of the unit. When unit is operated in a small
enclosure, a door or wall with a minimum of 2.3 sq ft of louvers is recommended to provide proper air changes for unit function.
Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100
Roswell, Georgia 30076 • www.rheem.com
Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Brampton, Ontario L6Y 0P5 • www.rheem.ca
07/24 WP FORM NO. HP-400-NO SO
INTEGR AT ED HOME COMFOR
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
4
Hybrid Electric Heat Pump Accessories List
Earthquake Isolation KitLeak Sensor
7" Diameter UL Certified
Termination Kit
8" Collar for Flex Venting
Vibration Isolation KitShutoff Valve
6" Diameter UL Certified
Termination Kit
25' Flexible 8" Diameter Duct Kit
8" Diameter UL Certified
Termination Kit
5" Diameter UL Certified
Termination Kit
8" Rigid Elbow Duct Kit
Leak Sensor & Shutoff Valve Kit
UPGRADE KIT (for ProTerra
models without LeakGuard
only) – Add leak detector and
shuttoff valve to protect from
water damage
PART NUMBER DESCRIPTION USE FOR
AP19134 Leak Sensor Automatic detection of internal and external leaks
AS50618A Shutoff Valve Automatic shut off of water supply to unit
SP20882 Earthquake Isolation Kit Installations in seismic regions
SP20883 Vibration Isolation Kit Installation on non-concrete floors
SP20884 8" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 8" diameter
SP20885 7" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 7" diameter
SP20886 6" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 6" diameter
SP20887 5" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 5" diameter
SP20888 8" Collar for Flex Venting Exhaust only to the outside ducting configuration (no inlet duct)
SP20889 25' Flexible 8" Diameter Duct Kit For up to 25' of ducting
SP20890 8" Rigid Elbow Duct Kit Installation in tight places where space needs to be minimized
UPGRADE KIT
SP21265A Kit - Automatically Shutoff Valve Assembly Add leak detector, shutoff valve and S.O.V. extension harness for top
connection setup
Water
Residential Electric
Professional Prestige ProTerra
Hybrid Electric Heat Pump Water Heaters