HomeMy WebLinkAbout18507 86th Dr Ne_BLD5458_2025
Permit Packet Coversheet
Community and Economic Development
City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551
Page 1 of 1
Permit Number: Permit Type:
Address/Parcel: Completed (Month/Year):
Land Use
Notice of Decision
Staff Report
Application
Narrative
Legal Description
Vicinity Map
Site Plan
Landscape Plan
Complete Streets Checklist
Traffic Impact Analysis
Snohomish County Traffic Mitigation Offer
WSDOT Traffic Offer Form
Tree Survey
Stormwater Drainage Report
Geotech Report
Critical Area Evaluation Form
SEPA Checklist
Public Notice Material
Noticing and Related Documents
Water / Sewer Availability Certificate
Unanticipated Discovery Plan Form
Aerial Photo of Site
Proposed Building Materials
Lighting Plans and Lighting Cut Sheets
Color Elevations
Design Matrix
Plat Map
Title Report
Lot Closures
Preliminary Civil Plans
Archaeological Survey
o Confidential Documents. Contact the
City to obtain.
Topography (Existing Conditions)
CC&R’s
Deeds / Easements / Conveyances
/Dedications
Developer’s Agreement
Recorded Copies
Bonding or Assignment of Funds
o Confidential Documents. Contact the
City to obtain.
Letters and Project Documents
Other:
Civil
Issued Permit
Application
Other Applications
Construction Calculation Worksheet
Approved Plans
Review Comment Form
Letters and Project Documents
Other Agency Permits
Reports:
o Drainage Report Pg:
o Stormwater Pg:
o Geotech Pg:
o All Other Reports
SEPA and Noticing Materials
Inspections
As-Builts
Other:
Building
Issued Permit
Application
Additional Applications
Approved Plans
Site Plan
Letters and Project Documents
Calculations
Project Specification Manuals
Reports
Certificate of Occupancy
Inspections
Other:
BLD5458 Residential Single Family
18507 86th Dr Ne December 2024
✔
✔
✔
✔
CITY OF ARLINGTON
18204 59th Avenue NE, Arlington, WA 98223
INSP ECTIONS: 360-403-3417 - Permit Center: 360-403-3551
B UILDING PERM IT
18507 86TH DR NE
Parcel #:
Pe rmit #: 5458
PERMIT EXPIRES 180 DAYS AFTER
DATE OF ISSUANCE.
Scope of Work: Construct SFR Valuation: 543571.50
OWNER APPLICANT CONTRACTOR
BRIDGEMONT LLC Bridgemont LLC Robinett Homes, LLC
116 AVE C 116 Avenue C 116 Avenue C
SNOHOMISH, WA 98290 Snohomish, WA, 98290 Snohomish, WA 98290
4254902205 425-490-2205
LIC: 602167298 EXP: 01/31/2025
LIC: ROBINHL943LZ EXP: 10/19/2024
MECHANICAL CONTRACTOR PLUM B ING CONTRACTOR
LIC #:EXP:LIC #:EXP:
JOB DESCRIPTION
P ERMIT TYPE:RESIDENTIAL SINGLE FAMILY CODE YEAR:2018
STORIES:2 CONST. TYP E:VA
DWELLING UNITS:1 OCC GROUP :R-3; Residential
BUILDINGS:1 OCC LOAD:
PERMIT APPROVAL
The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any
other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the
Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any
period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice
or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is
authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or
any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or
decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or
on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or
federal law, or any order, proclamation, guidance or decision of the Governor.
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK
AUTHORIZED THEREBY; NO P ERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE
STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APP LICATION IS NOT A P ERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEP UTY AND
ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUP Y A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN
MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110.
SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on
your sales tax return form and coded City of Arlington #3101.
03/28/2024
Applicant Signature Date Building Official Date
Sarah Uplinger
CONDITIONS
See redlined drawings for additional requirements. Adhere to approved plans. Service elements are not allowed on the facade of the
structure. All electrical (PUD), heating units, AC units, etc. are to be placed on the side or rear of the structure. Approved job copy
shall be onsite for inspections. Call for inspections.
The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property
owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or
community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities
before commencing construction. The property owner shall ensure that the construction project complies with all applicable design
review requirements.
THIS P ERMIT AUTHORIZES ONLY THE WORK NOTED. THIS P ERMIT COVERS WORK TO BE DONE ON P RIVATE
PROPERTY ONLY. ANY CONSTRUCTION ON THE P UBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS,
MARQUEES, ETC.) WILL REQUIRE SEP ARATE PERMISSION.
PERM IT FEES
Date De s cription Fe e Amount
03/28/2024 Building Plan Review $3,365.77
03/28/2024 Processing/Technology $25.00
03/28/2024 Building Permit $5,175.02
03/28/2024 Park - Community SF $1,662.00
03/28/2024 State Surcharge - 1st DU $6.50
Total Due :$10,234.29
Total Payme nt:$10,234.29
B alance Due :$0.00
CALL FOR INSPECTIONS
Call by 3:30 pm for ne xt day ins pe ction, allow 48 hours for Fire Ins pe ctions
Whe n calling for an ins pe ction ple as e le ave the following information:
Pe rmit Numbe r, Type of Ins pe ction be ing re que s te d, and whe the r you pre fe r morning or afte rnoon
INSPECTION INFORM ATION Pas s /Fail
SITE PLAN FOR
IN THE NW 1/4 OF THE NW 1/4 OF SECTION 24, T.31N., R.5E., W.M.
LOT 15, BRIDGEMONT RB - AFN #202212215003
HOUSE ELEVATIONS:
LEGEND:
OWNER:APPLICANT & CONTACT:
PARCEL DATA TAX ACCOUNT NUMBER:
NOTES:
6/28/2023 7:43:32 PM
tecinstruct LLC
4111 164th St SW
Unit 51
Lynnwood, WA 98087
Phone (206) 553 9076
rheimisch@yahoo.com
Engineering
1. LATERAL DESIGN
Project: Robinett Homes, Plan 3038
tecinstruct LLC
1.1 Seismic Design
Criteria Basic Seismic-Force-Resisting System Diaphragms / Shear Walls
Medium Building Height H = 25 ft
Seimic Use Group II
Importance Factor Ie = 1.0
Site Class D
Seismic Design Category D
Response Factor R = 6.5 (light frame wood building)
Seismic Response Coefficient Cs = 0.15
Building Weight
The weight of the walls is applied by adding 5 psf to the roof DL and 10 psf to the floor DL .
With the flat roof snow load 38 psf, 20% of the snow load is added to the roof DL (ASCE 12.7.2.4)
2nd level W = (15 + 5 + 0.2 x 38) x 1,900 sqft = 52,440 lbs
1st level W = (20 + 10) x 1,900 sqft = 57,000 lbs
Total Building Weight W = 109,440 lbs
Base Shear VBase = Cs x W = 0.15 x 109,440 = 16,420 lbs
Design Shear: To convert from strength level to ASD, Base Shear is multiplied by 0.7
VDesign = 0.7 x 16,420 = 11,500 lbs
Vertical Distribution: Fx = Cvx x V = Cvx x 11,500
Cvx = (wx x hxk) / ∑ (wi x hik) with k = 1.0 for T < 0.5 sec
Level wx hx wxhx wxhx/∑wihi Fx LLR vxFR LFR vxLR
(lb) (ft) (lb-ft) (%) (lbs) (ft) (plf) (ft) (plf)
2nd 52,440 17 891,480 63 7,245 50 145 42 170
1st 57,000 9 513,000 37 4,255 50 85 45 95
∑ 109,440 --- 1,404,480 100 11,500
Project: Robinett Homes, Plan 3038
tecinstruct LLC
1.2 Wind Design
Directional Procedure, Part 2 (simplified method) per ASCE 7-10, Chapter 27.5
Design Criteria: Enclosed Simple Diaphragm Building
Risk Category II
Basic Wind Speed per Table 26.5-1A 110 MpH
Directionality Factor Kd 0.85
Exposure Category C
As this design is used as a basic plan for multiple locations, conservatively category
„C“ is used to determine wind loads
Wind Speed up factor Kzt 1.0
Enclosure Classification enclosed
Net pressure at top of wall ph , Table 27.6-1 26.2 psf
(conservatively also used for bottom of wall)
As the shear wall design is performed for ASD, the load is multiplied with 0.7
Applied wind pressure 0.7 x 26.2 18.34, say 20 psf
Uniform wind loads on diaphragms
Roof w/ trib h 11 ft w = 10 x 20 = 220 plf
Floor w/ trib h 9 ft w = 9 x 20 = 180 plf
°
°
4'
8' 4"
4'
6020 2030
4 x 8 4 x 8
4,620 lbs W
3,570 lbs S
220 plf Wind / 170 plf Seismic
AC
4,620 lbs W
3,570 lbs S
P1-6 P1-6 P1-6 A
P1-6 AA
Sh
e
a
r
W
a
l
l
L
a
y
o
u
t
2
n
d
L
e
v
e
l
°
°
4'
8' 4"
°
DROP
ZONE
4'
2050 2050
60-94" S.G.D.
I
5-1/8 x 12" GLB
4x104x10
I
I
I
1,980 lbs W
1,045 lbs S
180 plf Wind / 95 plf Seismic
AC
3,960 lbs W
2,090 lbs S
B
1,980 lbs W
1,045 lbs S
P1-3 P1-3 P1-3 11
P1-6
P1-6
22
22
P1-6 11
Sh
e
a
r
W
a
l
l
L
a
y
o
u
t
1
s
t
L
e
v
e
l
Pr
o
j
e
c
t
:
R
o
b
i
n
e
t
t
P
l
a
n
3
0
8
3
Sh
e
a
r
W
a
l
l
T
y
p
e
s
SW
O
S
B
N
a
i
l
s
N
a
i
l
s
N
a
i
l
s
B
o
u
n
d
a
r
y
S
e
i
s
m
i
c
W
i
n
d
A
n
c
h
o
r
ty
p
e
e
d
g
e
f
i
e
l
d
M
e
m
b
e
r
l
i
s
t
x
.
9
4
x
1
.
4
Bo
l
t
5
/
8
"
@
@
(t
o
a
d
j
u
s
t
@
(i
n
o
.
c
.
)
(
i
n
o
.
c
.
)
fo
r
H
F
)
p
l
f
(
i
n
o
.
c
.
)
P1
-
6
7/
1
6
"
8
d
6
"
1
2
"
2
x
2
2
5
3
1
5
4
8
"
P1
-
3
7/
1
6
"
8
d
3
"
1
2
"
3
x
4
2
5
5
9
0
3
6
"
Ro
o
f
7/
1
6
"
8
d
6
"
1
2
"
2x
2
2
6
3
1
6
Fl
o
o
r
3/
4
"
C
D
X
10
d
6"
12
"
2x
30
0
4
2
0
St
r
a
p
s
Ca
l
l
o
u
t
S
t
r
a
p
A
l
l
W
o
o
d
N
a
i
l
s
/
T
M
e
m
b
e
r
B
o
l
t
s
(l
b
s
)
(
i
n
)
A
MS
T
3
7
2
3
4
5
(
2
)
2
x
2
0
-
1
6
d
B
MS
T
C
4
8
B
3
3
3
8
0
(
2
)
2
x
3
8
-
1
0
d
Ho
l
d
o
w
n
s
Ca
l
l
o
u
t
H
D
A
l
l
W
o
o
d
B
o
l
t
B
o
l
t
T
M
e
m
b
e
r
t
y
p
e
e
m
b
m
t
.
(l
b
s
)
1
HD
U
2
2
2
1
5
(
2
)
2
x
S
B
5
/
8
x
2
4
1
8
"
2
HD
U
4
3
2
8
5
(
2
)
2
x
S
B
5
/
8
x
2
4
1
8
"
te
c
i
n
s
t
r
u
c
t
L
L
C
Pr
o
j
e
c
t
:
R
o
b
i
n
e
t
t
P
l
a
n
3
0
8
3
Gr
i
d
3
W
i
n
d
Sh
e
a
r
d
e
s
i
g
n
O
v
e
r
t
u
r
n
i
n
g
Le
v
e
l
S
h
e
a
r
S
h
e
a
r
L
e
n
g
t
h
S
h
e
a
r
S
W
P
a
n
e
l
L
h
A
s
p
e
c
t
M
o
t
W
a
l
l
R
/
Fl
M
r
e
s
M
t
o
t
M
t
o
t
U
p
l
i
f
t
H
W
st
o
r
y
a
c
c
t
o
t
a
l
u
n
i
f
o
r
m
T
y
p
e
Ra
t
i
o
t
r
i
b
.
H
t
r
i
b
.
L
R
e
s
t
r
.
a
c
c
T
V
(
l
b
s
)
V
(
l
b
s
)
L
(
f
t
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
k
/
L
(
l
b
-
f
t
)
(
f
t
)
(
f
t)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
s
2
55
0
0
5
5
0
0
3
0
.
0
18
3
P
1
-
6
3-
1
p
3
0
.
0
8
0
.
2
7
4
4
0
0
0
8
2
2
6
5
5
0
1
7
4
5
0
1
7
4
5
0
58
2
MS
T
3
7
1
23
4
0
7
8
4
0
2
8
.
0
28
0
P
1
-
3
3-
1
2
8
.
0
9
0
.
3
2
7
0
5
6
0
9
2
2
5
4
1
0
4
5
1
5
0
6
2
6
0
0
22
3
6
HD
U
2
ba
s
e
d
o
n
p
e
r
f
d
e
s
i
g
n
Bo
l
d
i
n
d
i
c
a
t
e
s
t
h
a
t
w
i
n
d
g
o
v
e
r
n
s
p
Pa
n
e
l
U
n
i
t
h
o
p
/
Σ
L
i
L
Sh
e
a
t
h
i
n
g
Co
q
'
Na
i
l
i
n
g
Sh
e
a
r
h
t
o
t
a
l
t
o
t
a
l
f
r
o
m
ΣL
i
/
L
SD
P
W
S
(p
l
f
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
%
4
.
3
.
3
.
5
1-
1
2
n
d
18
3
h
/
2
2
2
3
0
7
3
0
.
8
8
28
4
P1
-
6
1-
1
1
s
t
28
0
2
h
/
3
2
4
2
8
8
6
0
.
8
6
38
0
P1
-
3
pe
r
f
o
r
a
t
e
d
p
a
n
e
l
te
c
i
n
s
t
r
u
c
t
L
L
C
Pr
o
j
e
c
t
:
R
o
b
i
n
e
t
t
P
l
a
n
3
0
8
3
Gr
i
d
1
S
e
i
s
m
i
c
Sh
e
a
r
d
e
s
i
g
n
O
v
e
r
t
u
r
n
i
n
g
Le
v
e
l
S
h
e
a
r
S
h
e
a
r
L
e
n
g
t
h
S
h
e
a
r
S
W
P
a
n
e
l
L
h
A
s
p
e
c
t
M
o
t
W
a
l
l
R
/
Fl
M
r
e
s
M
t
o
t
M
t
o
t
U
p
l
i
f
t
H
W
st
o
r
y
a
c
c
t
o
t
a
l
u
n
i
f
o
r
m
T
y
p
e
Ra
t
i
o
t
r
i
b
.
H
t
r
i
b
.
L
R
e
s
t
r
.
a
c
c
T
V
(
l
b
s
)
V
(
l
b
s
)
L
(
f
t
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
k
/
L
(
l
b
-
f
t
)
(
f
t
)
(
f
t)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
s
2
36
2
5
3
6
2
5
3
0
.
0
1
2
1
P
1
-
6
3
-
1
p
3
0
.
0
8
0
.
2
7
2
9
0
0
0
8
2
2
6
5
5
0
2
4
5
0
2
4
5
0
82
MS
T
3
7
1
11
0
5
4
7
3
0
2
8
.
0
1
6
9
P
1
-
6
3
-
1
2
8
.
0
9
0
.
3
2
4
2
5
7
0
9
2
2
5
4
1
0
1
7
1
6
0
1
9
6
10
70
0
HD
U
2
ba
s
e
d
o
n
p
e
r
f
d
e
s
i
g
n
Bo
l
d
i
n
d
i
c
a
t
e
s
t
h
a
t
s
e
i
s
m
i
c
g
o
v
e
r
n
s
p
Pa
n
e
l
U
n
i
t
h
o
p
/
Σ
L
i
L
Sh
e
a
t
h
i
n
g
Co
q
'
Na
i
l
i
n
g
Sh
e
a
r
h
t
o
t
a
l
t
o
t
a
l
f
r
o
m
ΣL
i
/
L
SD
P
W
S
(p
l
f
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
%
4
.
3
.
3
.
5
1-
1
2
n
d
12
1
h
/
2
2
2
3
0
7
3
0
.
8
8
18
8
P1
-
6
1-
1
1
s
t
16
9
2
h
/
3
2
4
2
8
8
6
0
.
8
6
22
9
P1
-
6
pe
r
f
o
r
a
t
e
d
p
a
n
e
l
te
c
i
n
s
t
r
u
c
t
L
L
C
Pr
o
j
e
c
t
:
R
o
b
i
n
e
t
t
P
l
a
n
3
0
8
3
Gr
i
d
2
W
i
n
d
Sh
e
a
r
d
e
s
i
g
n
O
v
e
r
t
u
r
n
i
n
g
Le
v
e
l
S
h
e
a
r
S
h
e
a
r
L
e
n
g
t
h
S
h
e
a
r
S
W
P
a
n
e
l
L
h
A
s
p
e
c
t
M
o
t
W
a
l
l
R
/
Fl
M
r
e
s
M
t
o
t
M
t
o
t
U
p
l
i
f
t
H
W
st
o
r
y
a
c
c
t
o
t
a
l
u
n
i
f
o
r
m
T
y
p
e
Ra
t
i
o
t
r
i
b
.
H
t
r
i
b
.
L
R
e
s
t
r
.
a
c
c
T
V
(
l
b
s
)
V
(
l
b
s
)
L
(
f
t
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
k
/
L
(
l
b
-
f
t
)
(
f
t
)
(
f
t)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
s
2
No
s
h
e
a
r
w
a
l
l
s
i
n
g
r
i
d
2
a
t
2
n
d
l
e
v
e
l
1
45
0
0
4
5
0
0
1
4
.
0
32
1
P
1
-
6
2-
1
8
.
0
9
1
.
1
3
2
3
1
4
3
9
2
1
9
8
0
2
1
1
6
3
2
1
1
6
3
26
4
5
HD
U
4
2-
2
6
.
0
9
1
.
5
1
7
3
5
7
9
2
1
0
8
9
1
6
2
6
8
1
6
2
6
8
27
1
1
HD
U
4
Bo
l
d
i
n
d
i
c
a
t
e
s
t
h
a
t
w
i
n
d
g
o
v
e
r
n
s
te
c
i
n
s
t
r
u
c
t
L
L
C
Pr
o
j
e
c
t
:
R
o
b
i
n
e
t
t
P
l
a
n
3
0
8
3
Gr
i
d
2
S
e
i
s
m
i
c
Sh
e
a
r
d
e
s
i
g
n
O
v
e
r
t
u
r
n
i
n
g
Le
v
e
l
S
h
e
a
r
S
h
e
a
r
L
e
n
g
t
h
S
h
e
a
r
S
W
P
a
n
e
l
L
h
A
s
p
e
c
t
M
o
t
W
a
l
l
R
/
Fl
M
r
e
s
M
t
o
t
M
t
o
t
U
p
l
i
f
t
H
W
st
o
r
y
a
c
c
t
o
t
a
l
u
n
i
f
o
r
m
T
y
p
e
Ra
t
i
o
t
r
i
b
.
H
t
r
i
b
.
L
R
e
s
t
r
.
a
c
c
T
V
(
l
b
s
)
V
(
l
b
s
)
L
(
f
t
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
k
/
L
(
l
b
-
f
t
)
(
f
t
)
(
f
t)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
s
2
No
s
h
e
a
r
w
a
l
l
s
i
n
g
r
i
d
2
a
t
2
n
d
l
e
v
e
l
1
21
2
5
2
1
2
5
1
4
.
0
1
5
2
P
1
-
6
2
-
1
8
.
0
9
1
.
1
3
1
0
9
2
9
9
2
1
9
8
0
8
9
4
9
8
9
4
9
11
1
9
HD
U
2
2-
2
6
.
0
9
1
.
5
8
1
9
6
9
2
1
0
8
9
7
1
0
7
7
1
0
7
11
8
5
HD
U
2
Bo
l
d
i
n
d
i
c
a
t
e
s
t
h
a
t
s
e
i
s
m
i
c
g
o
v
e
r
n
s
te
c
i
n
s
t
r
u
c
t
L
L
C
Pr
o
j
e
c
t
:
R
o
b
i
n
e
t
t
P
l
a
n
3
0
8
3
Gr
i
d
3
W
i
n
d
Sh
e
a
r
d
e
s
i
g
n
O
v
e
r
t
u
r
n
i
n
g
Le
v
e
l
S
h
e
a
r
S
h
e
a
r
L
e
n
g
t
h
S
h
e
a
r
S
W
P
a
n
e
l
L
h
A
s
p
e
c
t
M
o
t
W
a
l
l
R
/
Fl
M
r
e
s
M
t
o
t
M
t
o
t
U
p
l
i
f
t
H
W
st
o
r
y
a
c
c
t
o
t
a
l
u
n
i
f
o
r
m
T
y
p
e
Ra
t
i
o
t
r
i
b
.
H
t
r
i
b
.
L
R
e
s
t
r
.
a
c
c
T
V
(
l
b
s
)
V
(
l
b
s
)
L
(
f
t
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
k
/
L
(
l
b
-
f
t
)
(
f
t
)
(
f
t)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
s
2
55
0
0
5
5
0
0
3
3
.
0
16
7
P
1
-
6
3-
1
3
3
.
0
8
0
.
2
4
4
4
0
0
0
8
2
3
2
1
7
5
1
1
8
2
5
1
1
8
2
5
35
8
MS
T
3
7
1
21
6
0
7
6
6
0
3
9
.
0
19
6
P
1
-
6
3-
1
3
9
.
0
9
0
.
2
3
6
8
9
4
0
9
2
4
9
5
5
0
1
9
3
9
1
3
1
2
1
6
80
0
HD
U
2
Bo
l
d
i
n
d
i
c
a
t
e
s
t
h
a
t
w
i
n
d
g
o
v
e
r
n
s
te
c
i
n
s
t
r
u
c
t
L
L
C
Pr
o
j
e
c
t
:
R
o
b
i
n
e
t
t
P
l
a
n
3
0
8
3
Gr
i
d
3
S
e
i
s
m
i
c
Sh
e
a
r
d
e
s
i
g
n
O
v
e
r
t
u
r
n
i
n
g
Le
v
e
l
S
h
e
a
r
S
h
e
a
r
L
e
n
g
t
h
S
h
e
a
r
S
W
P
a
n
e
l
L
h
A
s
p
e
c
t
M
o
t
W
a
l
l
R
/
Fl
M
r
e
s
M
t
o
t
M
t
o
t
U
p
l
i
f
t
H
W
st
o
r
y
a
c
c
t
o
t
a
l
u
n
i
f
o
r
m
T
y
p
e
Ra
t
i
o
t
r
i
b
.
H
t
r
i
b
.
L
R
e
s
t
r
.
a
c
c
T
V
(
l
b
s
)
V
(
l
b
s
)
L
(
f
t
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
k
/
L
(
l
b
-
f
t
)
(
f
t
)
(
f
t)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
s
2
36
2
5
3
6
2
5
3
3
.
0
1
1
0
P
1
-
6
3
-
1
3
3
.
0
8
0
.
2
4
2
9
0
0
0
8
2
3
2
1
7
5
-
3
1
7
5
-
3
1
75
-9
6
no
t
r
q
d
1
10
2
0
4
6
4
5
3
9
.
0
1
1
9
P
1
-
6
3
-
1
3
9
.
0
9
0
.
2
3
4
1
8
0
5
9
2
4
9
5
5
0
-
7
7
4
5
-
1
0
92
0
-2
8
0
no
t
r
q
d
Bo
l
d
i
n
d
i
c
a
t
e
s
t
h
a
t
s
e
i
s
m
i
c
g
o
v
e
r
n
s
te
c
i
n
s
t
r
u
c
t
L
L
C
Pr
o
j
e
c
t
:
R
o
b
i
n
e
t
t
P
l
a
n
3
0
8
3
Gr
i
d
A
W
i
n
d
Sh
e
a
r
d
e
s
i
g
n
O
v
e
r
t
u
r
n
i
n
g
Le
v
e
l
S
h
e
a
r
S
h
e
a
r
L
e
n
g
t
h
S
h
e
a
r
S
W
P
a
n
e
l
L
h
A
s
p
e
c
t
M
o
t
W
a
l
l
R
/
Fl
M
r
e
s
M
t
o
t
M
t
o
t
U
p
l
i
f
t
H
W
st
o
r
y
a
c
c
t
o
t
a
l
u
n
i
f
o
r
m
T
y
p
e
Ra
t
i
o
t
r
i
b
.
H
t
r
i
b
.
L
R
e
s
t
r
.
a
c
c
T
V
(
l
b
s
)
V
(
l
b
s
)
L
(
f
t
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
k
/
L
(
l
b
-
f
t
)
(
f
t
)
(
f
t)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
s
2
46
2
0
4
6
2
0
4
9
.
0
94
P
1
-
3
A-
1
p
1
0
.
0
8
0
.
8
7
5
4
3
8
1
5
6
5
5
5
9
8
8
9
8
8
99
MS
T
3
7
A-
2
p
1
6
.
0
8
0
.
5
1
2
0
6
9
8
2
7
4
4
0
4
6
2
9
4
6
2
9
28
9
MS
T
3
7
A
-
3
p
2
3
.
0
8
0
.
3
5
1
7
3
4
9
8
1
5
3
5
7
0
8
-
1
8
3
5
9
-
1
8
3
5
9
-7
9
8
no
t
r
q
d
ba
s
e
d
o
n
p
e
r
f
d
e
s
i
g
n
1
19
8
0
6
6
0
0
2
7
.
0
24
4
P
1
-
6
A-
1
1
2
.
0
9
0
.
7
5
2
6
4
0
0
9
5
5
7
9
6
2
0
6
0
4
2
1
5
9
2
17
9
9
HD
U
2
P1
-
3
A-
2
p
7
.
0
9
1
.
2
9
1
5
4
0
0
9
5
1
9
1
1
1
3
4
8
9
1
8
1
1
8
25
8
8
HD
U
4
P1
-
6
A-
3
4
.
0
8
2
7
8
2
2
8
5
5
4
6
7
2
7
6
7
2
7
6
18
1
9
HD
U
2
P1
-
6
A-
4
4
.
0
8
2
7
8
2
2
8
5
5
4
6
7
2
7
6
7
2
7
6
18
1
9
HD
U
2
Bo
l
d
i
n
d
i
c
a
t
e
s
t
h
a
t
w
i
n
d
g
o
v
e
r
n
s
p
p
e
r
f
o
r
a
t
e
d
p
a
n
e
l
Pa
n
e
l
U
n
i
t
h
o
p
/
Σ
L
i
L
S
h
e
a
t
h
i
n
g
C
o
q
'
N
a
i
l
i
n
g
Sh
e
a
r
h
t
o
t
a
l
t
o
t
a
l
f
r
o
m
ΣL
i
/
L
SD
P
W
S
(p
l
f
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
%
4
.
3
.
3
.
5
A-
1
2
n
d
94
5
h
/
6
5
1
0
5
0
0
.
5
7
33
0
P1
-
3
A-
2
2
n
d
94
5
h
/
6
8
1
6
5
0
0
.
5
7
33
0
P1
-
3
A-
3
2
n
d
94
2
h
/
3
1
0
2
3
4
3
0
.
6
4
33
8
P1
-
3
A-
2
1
s
t
24
4
h
/
2
5
7
7
1
0
.
8
7
39
3
P1
-
3
te
c
i
n
s
t
r
u
c
t
L
L
C
Pr
o
j
e
c
t
:
R
o
b
i
n
e
t
t
P
l
a
n
3
0
8
3
Gr
i
d
A
S
e
i
s
m
i
c
Sh
e
a
r
d
e
s
i
g
n
O
v
e
r
t
u
r
n
i
n
g
Le
v
e
l
S
h
e
a
r
S
h
e
a
r
L
e
n
g
t
h
S
h
e
a
r
S
W
P
a
n
e
l
L
h
A
s
p
e
c
t
M
o
t
W
a
l
l
R
/
Fl
M
r
e
s
M
t
o
t
M
t
o
t
U
p
l
i
f
t
H
W
st
o
r
y
a
c
c
t
o
t
a
l
u
n
i
f
o
r
m
T
y
p
e
Ra
t
i
o
t
r
i
b
.
H
t
r
i
b
.
L
R
e
s
t
r
.
a
c
c
T
V
(
l
b
s
)
V
(
l
b
s
)
L
(
f
t
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
k
/
L
(
l
b
-
f
t
)
(
f
t
)
(
f
t)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
s
2
35
7
0
3
5
7
0
4
9
.
0
7
3
P
1
-
3
A
-
1
p
1
0
.
0
8
0
.
8
5
8
2
9
8
1
5
6
5
5
5
-
7
2
6
-
7
2
6
-7
3
no
t
r
q
d
A-
2
p
1
6
.
0
8
0
.
5
9
3
2
6
8
2
7
4
4
0
1
8
8
6
1
8
8
6
11
8
MS
T
3
7
A
-
3
p
2
3
.
0
8
0
.
3
5
1
3
4
0
6
8
1
5
3
5
7
0
8
-
2
2
3
0
2
-
2
2
3
0
2
-9
7
0
no
t
r
q
d
ba
s
e
d
o
n
p
e
r
f
d
e
s
i
g
n
1
10
4
5
4
6
1
5
2
7
.
0
1
7
1
P
1
-
6
A
-
1
1
2
.
0
9
0
.
7
5
1
8
4
6
0
9
5
5
7
9
6
1
2
6
6
4
1
1
9
3
8
99
5
HD
U
2
P1
-
3
A
-
2
p
7
.
0
9
1
.
2
9
1
0
7
6
8
9
5
1
9
1
1
8
8
5
7
1
0
7
4
3
15
3
5
HD
U
4
P1
-
6
A-
3
4
.
0
8
2
5
4
7
0
8
5
5
4
6
4
9
2
4
4
9
2
4
12
3
1
HD
U
2
P1
-
6
A-
4
4
.
0
8
2
5
4
7
0
8
5
5
4
6
4
9
2
4
4
9
2
4
12
3
1
HD
U
2
Bo
l
d
i
n
d
i
c
a
t
e
s
t
h
a
t
s
e
i
s
m
i
c
g
o
v
e
r
n
s
p
p
e
r
f
o
r
a
t
e
d
p
a
n
e
l
Pa
n
e
l
U
n
i
t
h
o
p
/
Σ
L
i
L
S
h
e
a
t
h
i
n
g
C
o
q
'
N
a
i
l
i
n
g
Sh
e
a
r
h
t
o
t
a
l
t
o
t
a
l
f
r
o
m
ΣL
i
/
L
SD
P
W
S
(p
l
f
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
%
4
.
3
.
3
.
5
A-
1
2
n
d
73
5
h
/
6
5
1
0
5
0
0
.
5
7
2
5
6
P1
-
3
A-
2
2
n
d
73
5
h
/
6
8
1
6
5
0
0
.
5
7
2
5
6
P1
-
3
A-
3
2
n
d
73
2
h
/
3
1
0
2
3
4
3
0
.
6
4
2
6
2
P1
-
3
A-
2
1
s
t
17
1
h
/
2
5
7
7
1
0
.
8
7
2
7
5
P1
-
3
te
c
i
n
s
t
r
u
c
t
L
L
C
Pr
o
j
e
c
t
:
R
o
b
i
n
e
t
t
P
l
a
n
3
0
8
3
Gr
i
d
B
W
i
n
d
Sh
e
a
r
d
e
s
i
g
n
O
v
e
r
t
u
r
n
i
n
g
Le
v
e
l
S
h
e
a
r
S
h
e
a
r
L
e
n
g
t
h
S
h
e
a
r
S
W
P
a
n
e
l
L
h
A
s
p
e
c
t
M
o
t
W
a
l
l
R
/
Fl
M
r
e
s
M
t
o
t
M
t
o
t
U
p
l
i
f
t
H
W
st
o
r
y
a
c
c
t
o
t
a
l
u
n
i
f
o
r
m
T
y
p
e
Ra
t
i
o
t
r
i
b
.
H
t
r
i
b
.
L
R
e
s
t
r
.
a
c
c
T
V
(
l
b
s
)
V
(
l
b
s
)
L
(
f
t
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
k
/
L
(
l
b
-
f
t
)
(
f
t
)
(
f
t)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
s
2
No
s
h
e
a
r
w
a
l
l
s
i
n
g
r
i
d
B
a
t
2
n
d
l
e
v
e
l
71
5
f
r
o
m
g
r
i
d
A
a
b
o
v
e
1
39
6
0
4
6
7
5
3
4
.
0
13
8
P
1
-
6
B-
1
1
1
.
0
9
0
.
8
2
1
3
6
1
3
9
5
4
8
5
1
8
7
6
2
8
7
6
2
79
7
HD
U
2
B-
2
2
3
.
0
9
0
.
3
9
2
8
4
6
3
9
5
2
1
7
3
5
6
7
2
8
6
7
2
8
29
3
HD
U
2
Bo
l
d
i
n
d
i
c
a
t
e
s
t
h
a
t
w
i
n
d
g
o
v
e
r
n
s
te
c
i
n
s
t
r
u
c
t
L
L
C
Pr
o
j
e
c
t
:
R
o
b
i
n
e
t
t
P
l
a
n
3
0
8
3
Gr
i
d
B
S
e
i
s
m
i
c
Sh
e
a
r
d
e
s
i
g
n
O
v
e
r
t
u
r
n
i
n
g
Le
v
e
l
S
h
e
a
r
S
h
e
a
r
L
e
n
g
t
h
S
h
e
a
r
S
W
P
a
n
e
l
L
h
A
s
p
e
c
t
M
o
t
W
a
l
l
R
/
Fl
M
r
e
s
M
t
o
t
M
t
o
t
U
p
l
i
f
t
H
W
st
o
r
y
a
c
c
t
o
t
a
l
u
n
i
f
o
r
m
T
y
p
e
Ra
t
i
o
t
r
i
b
.
H
t
r
i
b
.
L
R
e
s
t
r
.
a
c
c
T
V
(
l
b
s
)
V
(
l
b
s
)
L
(
f
t
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
k
/
L
(
l
b
-
f
t
)
(
f
t
)
(
f
t)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
s
2
No
s
h
e
a
r
w
a
l
l
s
i
n
g
r
i
d
B
a
t
2
n
d
l
e
v
e
l
71
5
f
r
o
m
g
r
i
d
A
a
b
o
v
e
1
20
9
0
2
8
0
5
3
4
.
0
8
3
P
1
-
6
B
-
1
1
1
.
0
9
0
.
8
2
8
1
6
8
9
5
4
8
5
1
3
3
1
7
3
3
1
7
30
2
HD
U
2
B-
2
2
3
.
0
9
0
.
3
9
1
7
0
7
8
9
5
2
1
7
3
5
-
4
6
5
8
-
4
6
5
8
-2
0
3
no
t
r
q
d
Bo
l
d
i
n
d
i
c
a
t
e
s
t
h
a
t
s
e
i
s
m
i
c
g
o
v
e
r
n
s
te
c
i
n
s
t
r
u
c
t
L
L
C
Pr
o
j
e
c
t
:
R
o
b
i
n
e
t
t
P
l
a
n
3
0
8
3
Gr
i
d
C
W
i
n
d
Sh
e
a
r
d
e
s
i
g
n
O
v
e
r
t
u
r
n
i
n
g
Le
v
e
l
S
h
e
a
r
S
h
e
a
r
L
e
n
g
t
h
S
h
e
a
r
S
W
P
a
n
e
l
L
h
A
s
p
e
c
t
M
o
t
W
a
l
l
R
/
Fl
M
r
e
s
M
t
o
t
M
t
o
t
U
p
l
i
f
t
H
W
st
o
r
y
a
c
c
t
o
t
a
l
u
n
i
f
o
r
m
T
y
p
e
Ra
t
i
o
t
r
i
b
.
H
t
r
i
b
.
L
R
e
s
t
r
.
a
c
c
T
V
(
l
b
s
)
V
(
l
b
s
)
L
(
f
t
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
k
/
L
(
l
b
-
f
t
)
(
f
t
)
(
f
t)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
s
2
46
2
0
4
6
2
0
5
1
.
0
91
P
1
-
6
C-
1
p
1
9
.
0
9
0
.
4
7
1
5
4
9
1
9
2
1
1
6
0
0
3
8
9
1
3
8
9
1
20
5
MS
T
C
4
8
B
3
C-
2
p
1
7
.
0
9
0
.
5
3
1
3
8
6
0
9
2
9
2
5
7
4
6
0
4
4
6
0
4
27
1
MS
T
3
7
C
-
3
p
1
4
.
0
9
0
.
6
4
1
1
4
1
4
9
2
6
2
3
7
5
1
7
7
5
1
7
7
37
0
MS
T
3
7
1
19
8
0
6
6
0
0
4
7
.
0
14
0
P
1
-
6
C-
1
4
.
5
9
2
5
6
8
7
9
5
7
5
6
4
9
3
1
8
8
2
2
19
6
1
HD
U
2
P1
-
3
C-
2
p
1
7
.
0
9
0
.
5
3
2
1
4
8
5
9
5
1
1
7
8
1
9
7
0
4
1
4
3
0
8
84
2
HD
U
2
P1
-
3
C-
3
p
1
4
.
0
9
0
.
6
4
1
7
6
9
4
9
5
7
9
3
8
9
7
5
6
1
4
9
3
3
10
6
7
HD
U
2
Bo
l
d
i
n
d
i
c
a
t
e
s
t
h
a
t
w
i
n
d
g
o
v
e
r
n
s
p
p
e
r
f
o
r
a
t
e
d
p
a
n
e
l
Pa
n
e
l
U
n
i
t
h
o
p
/
Σ
L
i
L
S
h
e
a
t
h
i
n
g
C
o
q
'
N
a
i
l
i
n
g
Sh
e
a
r
h
t
o
t
a
l
t
o
t
a
l
f
r
o
m
ΣL
i
/
L
SD
P
W
S
(p
l
f
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
%
4
.
3
.
3
.
5
C-
1
2
n
d
91
h
/
2
1
1
1
9
5
8
0
.
8
2
19
2
P1
-
6
C-
2
2
n
d
91
h
/
2
1
3
1
7
7
6
0
.
8
9
13
4
P1
-
6
C-
3
2
n
d
91
h
/
2
8
1
4
5
7
0
.
8
2
19
4
P1
-
6
C-
2
2
n
d
14
0
2
h
/
3
7
1
7
4
1
0
.
6
3
54
0
P1
-
3
C-
3
2
n
d
14
0
2
h
/
3
7
1
4
5
0
0
.
6
7
41
8
P1
-
3
te
c
i
n
s
t
r
u
c
t
L
L
C
Pr
o
j
e
c
t
:
R
o
b
i
n
e
t
t
P
l
a
n
3
0
8
3
Gr
i
d
C
S
e
i
s
m
i
c
Sh
e
a
r
d
e
s
i
g
n
O
v
e
r
t
u
r
n
i
n
g
Le
v
e
l
S
h
e
a
r
S
h
e
a
r
L
e
n
g
t
h
S
h
e
a
r
S
W
P
a
n
e
l
L
h
A
s
p
e
c
t
M
o
t
W
a
l
l
R
/
Fl
M
r
e
s
M
t
o
t
M
t
o
t
U
p
l
i
f
t
H
W
st
o
r
y
a
c
c
t
o
t
a
l
u
n
i
f
o
r
m
T
y
p
e
Ra
t
i
o
t
r
i
b
.
H
t
r
i
b
.
L
R
e
s
t
r
.
a
c
c
T
V
(
l
b
s
)
V
(
l
b
s
)
L
(
f
t
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
k
/
L
(
l
b
-
f
t
)
(
f
t
)
(
f
t)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
-
f
t
)
(
l
b
s
2
35
7
0
3
5
7
0
5
1
.
0
7
0
P
1
-
6
C
-
1
p
1
9
.
0
9
0
.
4
7
1
1
9
7
0
9
2
1
1
6
0
0
3
7
1
3
7
1
20
MS
T
C
4
8
B
3
C-
2
p
1
7
.
0
9
0
.
5
3
1
0
7
1
0
9
2
9
2
5
7
1
4
5
4
1
4
5
4
86
MS
T
3
7
C
-
3
p
1
4
.
0
9
0
.
6
4
8
8
2
0
9
2
6
2
3
7
2
5
8
3
2
5
8
3
18
5
MS
T
3
7
1
10
4
5
4
6
1
5
4
7
.
0
9
8
P
1
-
6
C
-
1
4
.
5
9
2
3
9
7
7
9
5
7
5
6
3
2
2
1
3
5
9
1
79
8
HD
U
2
P1
-
3
C
-
2
p
1
7
.
0
9
0
.
5
3
1
5
0
2
3
9
5
1
1
7
8
1
3
2
4
2
4
6
9
6
27
6
HD
U
2
P1
-
3
C-
3
p
1
4
.
0
9
0
.
6
4
1
2
3
7
2
9
5
7
9
3
8
4
4
3
4
7
0
1
7
50
1
HD
U
2
Bo
l
d
i
n
d
i
c
a
t
e
s
t
h
a
t
s
e
i
s
m
i
c
g
o
v
e
r
n
s
p
p
e
r
f
o
r
a
t
e
d
p
a
n
e
l
Pa
n
e
l
U
n
i
t
h
o
p
/
Σ
L
i
L
S
h
e
a
t
h
i
n
g
C
o
q
'
N
a
i
l
i
n
g
Sh
e
a
r
h
t
o
t
a
l
t
o
t
a
l
f
r
o
m
ΣL
i
/
L
SD
P
W
S
(p
l
f
)
v
(
p
l
f
)
(
f
t
)
(
f
t
)
%
4
.
3
.
3
.
5
C-
1
2
n
d
70
h
/
2
1
1
1
9
5
8
0
.
8
2
1
4
7
P1
-
6
C-
2
2
n
d
70
h
/
2
1
3
1
7
7
6
0
.
8
9
1
0
3
P1
-
6
C-
3
2
n
d
70
h
/
2
8
1
4
5
7
0
.
8
2
1
4
9
P1
-
6
C-
2
2
n
d
98
2
h
/
3
7
1
7
4
1
0
.
6
3
3
7
8
P1
-
3
C-
3
2
n
d
98
2
h
/
3
7
1
4
5
0
0
.
6
7
2
9
3
P1
-
3
te
c
i
n
s
t
r
u
c
t
L
L
C
tecinstruct LLC
4111 164th St SW
Unit 51
Lynnwood, WA 98087
Phone (206) 553 9076
rheimisch@yahoo.com
Engineering
2. GRAVITY DESIGN
Project: Robinett Homes, Plan 3038
tecinstruct LLC
2.1 Design Criteria
Dead Loads Roof Coating/Waterproofing 2.0
Sheathing OSB/Plywood 15/32“ 2.0
Trusses / Framing 3.0
Insulation R-38 1.2
Gypsum Board 5/8“ 2.8
Miscellaneous (Sprinkler, HVAC etc) 1.5
Total 12.5, say 15 psf
Floors Living Finished Floor (carpet) 1.0
Sheathing OSB/Plywood 3/4“ 2.5
Floor Joists / TJIs 2.5
Insulation R-11 1.0
Gypsum Board 5/8“ 2.8
Miscellaneous (Sprinkler, HVAC etc) 1.5
Non bearing partitions 8.0
Total 19.3, say 20 psf
Decks/Balconies Decking 3.0
Floor Joists / TJIs 2.5
Miscellaneous (Railing/Waterproofing) 1.5
Total 7.0 say 10 psf
Ext. Walls Siding 3.0
Sheathing 15/32“ OSB/Plywood 2.0
2x6“ Studs @ 16“ o.c. 1.5
Insulation R-21 0.6
Gypsum Board 5/8“ 2.8
Total 9.9, say 10 psf
Int. Walls 2x4“ Studs @ 16“ o.c. 1.5
Gypsum Board (2 sides) 5/8“ 5.6
Total 7.1, say 8 psf
Live Loads Roof 20 psf
Living areas 40 psf
Decks/Balconies 60 psf
Snow Load Snow Ground Load 38 psf
Snow Roof Load (no reduction applied) 38 psf
Project: Robinett Homes, Plan 3038
tecinstruct LLC
2.2 Key List
Roof
Key No. 1.1 Manufactured Truss Roof
Key No. 1.2 Overframing, HF No. 2, 2x6”, @ 24” o.c.
Key No. 1.3 Header, DF No. 2, 4x12”
Key No. 1.4 Header, DF No. 2, 4x10”
Key No. 1.5 Header, DF No. 2, 4x8”
Key No. 1.6 Header, DF No. 2, 4x6”
Floor above Main Level
Key No. 2.1 Manufactured Truss Roof above Garage and Porch
Key No. 2.2 TJI 230, 2-5/16x11-7/8”, @ 16” o.c. (Alternative: HF No. 2, 2x12”, @ 16” o.c.)
Key No. 2.3 Stair Stringers, HF No. 2, 2x12”, @ 16” o.c.
Key No. 2.4 Landing Joists, HF No. 2, 2x6”, @ 16” o.c.
Key No. 2.5 Glulam WS, flush, 24F-1.8E, 5-1/8x25-/12”
Key No. 2.6 Glulam WS, flush, 24F-1.8E, 5-1/8x12”
Key No. 2.7 Beam, flush, 4x12”
Key No. 2.8 Garage Header, DF No. 2, 6x12”
Key No. 2.9 Beam, DF No. 2. 6x12”
Key No. 2.10 Beam, DF No. 2. 6x12”
Key No. 2.11 Header, DF No. 2, 6x12”
Key No. 2.12 Header, DF No. 2, 4x10”
Key No. 2.13 Header, DF No. 2, 4x6”
Key No. 2.15 Post at Porch, HF No. 2, 6x6”, P.T.
Key No. 2.14 Post, DF No. 2, 6x6”
Key No. 2.15 Post at Porch, HF No. 2, 6x6”, P.T.
Framing above Crawl Space
Key No. 3.1 TJI 230, 2-5/16x11-7/8”, @ 16” o.c. (Alternative HF No. 2, 2x12”, @ 16” o.c.)
Key No. 3.2 Beam, DF No. 2, 4x10”
Foundation
Key No. 4.1 Continuous Footing, fc = 2,500 psi, 16x8”, w/ Stem Wall 8”
Key No. 4.2 Pad Footing, fc = 2,500 psi, 42x42x12”
Key No. 4.3 Pad Footing, fc = 2,500 psi, 30x30x12”
Key No. 4.4 Pad Footing, fc = 2,500 psi, 24x24x12”
Project: Robinett Homes, Plan 3038
tecinstruct LLC
2.3 Roof
Key No. 1.1 Manufactured Truss Roof
Span: L = varies
Load: DL = 15 psf
SL = 38 psf
Layout and design per manufacturer
Key No. 1.2 Overframing, HF No. 2, 2x6”, @ 24” o.c.
Per span tables
Key No. 1.3 Header, DF No. 2, 4x12”
Span: L = 8 ft
Load: roof w/ trib 15 ft
DL 15 x 15 = 225 plf
SL 15 x 38 = 570 plf
For calculation see design sheets.
Key No. 1.4 Header, DF No. 2, 4x10”
Span: L = 6 ft
Load: roof w/ trib 17 ft
DL 17 x 15 = 255 plf
SL 17 x 38 = 650 plf
For calculation see design sheets.
Key No. 1.5 Header, DF No. 2, 4x8”
Span: max L = 8 ft
Load: roof w/ trib 3 ft
DL 3 x 15 = 45 plf
SL 3 x 38 = 120 plf
For calculation see design sheets.
Key No. 1.6 Header, DF No. 2, 4x6”
Span: L = 2.5 ft
Load: roof w/ trib 15 ft
DL 15 x 15 = 225 plf
SL 15 x 38 = 570 plf
For calculation see design sheets.
Project: Robinett Homes, Plan 3038
tecinstruct LLC
2.4 Floor above Main Level
Key No. 2.1 Manufactured Truss Roof above Garage and Porch
Span: L = varies
Load: DL = 15 psf
SL = 38 psf
Layout and design per manufacturer
Key No. 2.2 TJI 230, 2-5/16x11-7/8”, @ 16” o.c. (Alternative: HF No. 2, 2x12”, @ 16” o.c.)
Span: L = 18 ft
Loads: DL = 20 psf
LL = 40 psf
Per iLevel span tables for deflection L/480
For HF, see design sheets
Key No. 2.3 Stair Stringers, HF No. 2, 2x12”, @ 16” o.c.
Span: L = 6 ft
Loads: DL = 20 psf
LL = 40 psf
Per span tables
Key No. 2.4 Landing Joists, HF No. 2, 2x6”, @ 16” o.c.
Span: L = 6 ft
Loads: DL = 20 psf
LL = 40 psf
Per span tables
Key No. 2.5 Glulam WS, flush, 24F-1.8E, 5-1/8x25-/12”
Span: L = 23 ft
Loads: upper roof w/ trib 20 ft, lower roof w/ trib 3 ft, floor w/ trib 8 ft, wall w/ h 8 ft
DL 23 x 15 + 8 x 20 + 8 x 10 = 585 plf
LL 8 x 40 = 320 plf
SL 23 x 38 = 875 plf
For calculation see design sheets
Key No. 2.6 Glulam WS, flush, 24F-1.8E, 5-1/8x12”
Span: L = 16 ft
Loads: floor w/ trib 12 ft
DL 12 x 20 = 240 plf
LL 12 x 40 = 480 plf
For calculation see design sheets
Project: Robinett Homes, Plan 3038
tecinstruct LLC
Key No. 2.7 Beam, flush, 4x12”
Span: L = 7 ft
Loads: floor w/ trib 14 ft
DL 14 x 20 = 280 plf
LL 14 x 40 = 560 plf
For calculation see design sheets
Key No. 2.8 Garage Header, DF No. 2, 6x12”
Span: L = 16 ft
Loads: lower roof w/ trib 4 ft
DL 4 x 15 = 60 plf
SL 4 x 38 = 160 plf
For calculation see design sheets
Key No. 2.9 Beam, DF No. 2. 6x12”
Span: L = 16 ft
Loads: roof w/ trib 6 ft
DL 6 x 15 = 90 plf
SL 6 x 38 = 230 plf
For calculation see design sheets
1% excess in stress is still within the intent of the design.
Key No. 2.10 Beam, DF No. 2. 6x12”
Span: L = 13 ft
Loads: roof w/ trib 3 ft, floor w/ trib 3 ft, wall w/ h 8 ft
DL 3 x 15 + 3 x 20 + 8 x 10 = 185 plf
LL 3 x 40 = 120 plf
SL 3 x 38 = 120 plf
For calculation see design sheets
1% excess in stress is still within the intent of the design.
Key No. 2.11 Header, DF No. 2, 6x12”
Span: L = 6 ft
Loads: upper roof w/ trib 15 ft, lower roof w/ trib 6 ft, floor w/ trib 10 ft, wall w/ h 8 ft
DL 21 x 15 + 10 x 20 + 8 x 10 = 595 plf
DL 10 x 40 = 400 plf
SL 23 x 38 = 875 plf
For calculation see design sheets
Key No. 2.12 Header, DF No. 2, 4x10”
Span: L = 7 ft
Loads: roof w/ trib 2 ft, floor w/ trib 8 ft, wall w/ h 8 ft
DL 2 x 15 + 8 x 20 + 8 x 10 = 270 plf
DL 8 x 40 = 320 plf
SL 2 x 38 = 80 plf
For calculation see design sheets
Project: Robinett Homes, Plan 3038
tecinstruct LLC
Key No. 2.13 Header, DF No. 2, 4x6”
Span: L = 5 ft
Loads: roof w/ trib 2 ft, floor w/ trib 3 ft, wall w/ h 8 ft
DL 2 x 15 + 3 x 20 + 8 x 10 = 170 plf
DL 3 x 40 = 120 plf
SL 2 x 38 = 80 plf
For calculation see design sheets. Also used for shorter spans.
Key No. 2.14 Post, DF No. 2, 6x6”
Height: H = 9 ft
Load: reaction from beam 2.5
PDL = 6,855 lbs
PLL = 10,500 lbs
For calculation see design sheets.
3% overstress is still within the intent of the design.
Key No. 2.15 Post at Porch, HF No. 2, 6x6”, P.T.
Height: H = 9 ft
Load: reaction from beam 2.9
PDL = 725 lbs
PLL = 1,850 lbs
Per inspection. Also used at front porch with less load.
Project: Robinett Homes, Plan 3038
tecinstruct LLC
2.5 Crawl Space
Key No. 3.1 TJI 230, 2-5/16x11-7/8”, @ 16” o.c. (Alternative HF No. 2, 2x12”, @ 16” o.c.)
Span: L = 18 ft
Loads: DL = 20 psf
LL = 40 psf
Same as 2.2
Key No. 3.2 Beam, DF No. 2, 4x10”
Max uniform load under load bearing wall
Span: L Continuous over several posts, >> designed as 3-span beam
= 4 + 4 + 4 ft
Load: (2) floors w/ tot trib 30 ft, wall w/ h 16 ft
DL 30 x 20 + 16 x 10 = 760 plf
LL 30 x 40 = 1,200 plf
For calculation see design sheets
Project: Robinett Homes, Plan 3038
tecinstruct LLC
2.6 Foundation
Key No. 4.1 Continuous Footing, fc = 2,500 psi, 16x8”, w/ Stem Wall 8”
Dimensions per prescriptive requirements
Reinforcement: (2) rebars # 4 longitudinal
hooked verticals # 3 @ 18” o.c., alternated
Key No. 4.2 Pad Footing, fc = 2,500 psi, 42x42x12”
Load from post 2.14
P = 17,355 lbs
Soil pressure 17,355 / 12.25 = 1,417 psf < 1,500
Rebars # 4 @ 6” o.c. each way
Key No. 4.3 Pad Footing, fc = 2,500 psi, 30x30x12”
Load reaction from (1.5x) beam 2.10
P 1.5 x 2,385 = 3,580 lbs
Soil pressure 2,575 / 4 = 530 psf < 1,500
Rebars # 4 @ 6” o.c. each way
Key No. 4.4 Pad Footing, fc = 2,500 psi, 24x24x12”
Load max P from post 2.15
P = 2,575 lbs
Soil pressure 2,575 / 4 = 644 psf < 1,500
Rebars # 4 @ 6” o.c. each way
Robinett Plan 3083
1_3 Header
Aug. 4, 2022 14:22
Design Check Calculation Sheet
WoodWorks Sizer 2019 (Update 4)
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
DL Dead Full UDL 225.0 plf
SL Snow Full UDL 570.0 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
8'-1.48"
8'0'
Unfactored:
Dead 914 914
Snow 2315 2315
Factored:
Total 3229 3229
Bearing:
Capacity
Beam 3229 3229
Support 3575 3575
Des ratio
Beam 1.00 1.00
Support 0.90 0.90
Load comb #2 #2
Length 1.48 1.48
Min req'd 1.48 1.48
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.11 1.11
Fcp sup 625 625
Lumber-soft, D.Fir-L (N), No.1/No.2, 4x12 (3-1/2"x11-1/4")
Supports: All - Timber-soft Beam, D.Fir-L (N) No.2
Total length: 8'-1.5"; Clear span: 7'-10.5"; Volume = 2.2 cu.ft.
Lateral support: top = at supports, bottom = at supports;
This section PASSES the design code check.
Analysis vs. Allowable Stress and Deflection using NDS 2018 :
Criterion Analysis Value Design Value Unit Analysis/Design
Shear fv = 91 Fv' = 207 psi fv/Fv' = 0.44
Bending(+) fb = 1034 Fb' = 1056 psi fb/Fb' = 0.98
Dead Defl'n 0.03 = < L/999
Live Defl'n 0.08 = < L/999 0.27 = L/360 in 0.30
Total Defl'n 0.11 = L/870 0.40 = L/240 in 0.28
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
WoodWorks® Sizer 2019 (Update 4)1_3 Header Page 2
Additional Data:
FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC#
Fv' 180 1.15 1.00 1.00 - - - - 1.00 1.00 2
Fb'+ 850 1.15 1.00 1.00 0.982 1.100 - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 2
Emin' 0.58 million 1.00 1.00 - - - - 1.00 1.00 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D + S
Bending(+): LC #2 = D + S
Deflection: LC #2 = D + S (live)
LC #2 = D + S (total)
Bearing : Support 1 – LC #2 = D + S
Support 2 – LC #2 = D + S
D=dead S=snow
All LC's are listed in the Analysis output
Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1
CALCULATIONS:
V max = 3180, V design = 2386 lbs; M(+) = 6360 lbs-ft
EIy = 664.44 lb-in^2
"Live" deflection is due to all non-dead loads (live, wind, snow…)
Total deflection = 1.0 dead + "live"
Lateral stability(+): Lu = 8' Le = 15'-10.25" RB = 13.2
Design Notes:
1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design
Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
Robinett Plan 3083
1_4 Header
Aug. 4, 2022 14:24
Design Check Calculation Sheet
WoodWorks Sizer 2019 (Update 4)
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
DL Dead Full UDL 255.0 plf
SL Snow Full UDL 650.0 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
6'-1.26"
6'0'
Unfactored:
Dead 778 778
Snow 1984 1984
Factored:
Total 2763 2763
Bearing:
Capacity
Beam 2763 2763
Support 3059 3059
Des ratio
Beam 1.00 1.00
Support 0.90 0.90
Load comb #2 #2
Length 1.26 1.26
Min req'd 1.26 1.26
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.11 1.11
Fcp sup 625 625
Lumber-soft, D.Fir-L (N), No.1/No.2, 4x10 (3-1/2"x9-1/4")
Supports: All - Timber-soft Beam, D.Fir-L (N) No.2
Total length: 6'-1.25"; Clear span: 5'-10.75"; Volume = 1.4 cu.ft.
Lateral support: top = at supports, bottom = at supports;
This section PASSES the design code check.
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
WoodWorks® Sizer 2019 (Update 4)1_4 Header Page 2
Analysis vs. Allowable Stress and Deflection using NDS 2018 :
Criterion Analysis Value Design Value Unit Analysis/Design
Shear fv = 91 Fv' = 207 psi fv/Fv' = 0.44
Bending(+) fb = 979 Fb' = 1160 psi fb/Fb' = 0.84
Dead Defl'n 0.02 = < L/999
Live Defl'n 0.05 = < L/999 0.20 = L/360 in 0.26
Total Defl'n 0.07 = < L/999 0.30 = L/240 in 0.24
Additional Data:
FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC#
Fv' 180 1.15 1.00 1.00 - - - - 1.00 1.00 2
Fb'+ 850 1.15 1.00 1.00 0.989 1.200 - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 2
Emin' 0.58 million 1.00 1.00 - - - - 1.00 1.00 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D + S
Bending(+): LC #2 = D + S
Deflection: LC #2 = D + S (live)
LC #2 = D + S (total)
Bearing : Support 1 – LC #2 = D + S
Support 2 – LC #2 = D + S
D=dead S=snow
All LC's are listed in the Analysis output
Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1
CALCULATIONS:
V max = 2715, V design = 1970 lbs; M(+) = 4073 lbs-ft
EIy = 369.34 lb-in^2
"Live" deflection is due to all non-dead loads (live, wind, snow…)
Total deflection = 1.0 dead + "live"
Lateral stability(+): Lu = 6' Le = 12'-1.13" RB = 10.5
Design Notes:
1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design
Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
Robinett Plan 3083
1_6 Header
Aug. 4, 2022 14:32
Design Check Calculation Sheet
WoodWorks Sizer 2019 (Update 4)
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
DL Dead Full UDL 225.0 plf
SL Snow Full UDL 570.0 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
2'-6.5"
2'-6"0'
Unfactored:
Dead 286 286
Snow 724 724
Factored:
Total 1010 1010
Bearing:
Capacity
Beam 1094 1094
Support 1211 1211
Des ratio
Beam 0.92 0.92
Support 0.83 0.83
Load comb #2 #2
Length 0.50* 0.50*
Min req'd 0.50* 0.50*
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.11 1.11
Fcp sup 625 625
*Minimum bearing length setting used: 1/2" for end supports
Lumber-soft, D.Fir-L (N), No.1/No.2, 4x6 (3-1/2"x5-1/2")
Supports: All - Timber-soft Beam, D.Fir-L (N) No.2
Total length: 2'-6.5"; Clear span: 2'-5.5"; Volume = 0.3 cu.ft.
Lateral support: top = at supports, bottom = at supports;
This section PASSES the design code check.
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
WoodWorks® Sizer 2019 (Update 4)1_6 Header Page 2
Analysis vs. Allowable Stress and Deflection using NDS 2018 :
Criterion Analysis Value Design Value Unit Analysis/Design
Shear fv = 48 Fv' = 207 psi fv/Fv' = 0.23
Bending(+) fb = 422 Fb' = 1271 psi fb/Fb' = 0.33
Dead Defl'n 0.00 = < L/999
Live Defl'n 0.01 = < L/999 0.08 = L/360 in 0.08
Total Defl'n 0.01 = < L/999 0.13 = L/240 in 0.07
Additional Data:
FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC#
Fv' 180 1.15 1.00 1.00 - - - - 1.00 1.00 2
Fb'+ 850 1.15 1.00 1.00 1.000 1.300 - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D + S
Bending(+): LC #2 = D + S
Deflection: LC #2 = D + S (live)
LC #2 = D + S (total)
Bearing : Support 1 – LC #2 = D + S
Support 2 – LC #2 = D + S
D=dead S=snow
All LC's are listed in the Analysis output
Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1
CALCULATIONS:
V max = 994, V design = 613 lbs; M(+) = 621 lbs-ft
EIy = 77.64 lb-in^2
"Live" deflection is due to all non-dead loads (live, wind, snow…)
Total deflection = 1.0 dead + "live"
Design Notes:
1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design
Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
Robinett Plan 3083
2_2 Floor Joist
Aug. 4, 2022 14:54
Design Check Calculation Sheet
WoodWorks Sizer 2019 (Update 4)
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
DL Dead Full Area 20.00(16.0") psf
LL Live Full UDL 40.0 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
18'-0.99"
18'0'
Unfactored:
Dead 241 241
Live 362 362
Factored:
Total 603 603
Bearing:
Capacity
Joist 603 603
Support 1163 1163
Des ratio
Joist 1.00 1.00
Support 0.52 0.52
Load comb #2 #2
Length 0.99 0.99
Min req'd 0.99 0.99
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.25 1.25
Fcp sup 625 625
Lumber-soft, Hem-Fir (N), No.1/No.2, 2x12 (1-1/2"x11-1/4")
Supports: All - Timber-soft Beam, D.Fir-L (N) No.2
Floor joist spaced at 16.0" c/c; Total length: 18'-1.0"; Clear span: 17'-11.0"; Volume = 2.1 cu.ft.
Lateral support: top = continuous, bottom = at supports; Repetitive factor: applied where permitted (refer to online help);
This section PASSES the design code check.
Analysis vs. Allowable Stress and Deflection using NDS 2018 :
Criterion Analysis Value Design Value Unit Analysis/Design
Shear fv = 48 Fv' = 145 psi fv/Fv' = 0.33
Bending(+) fb = 1024 Fb' = 1150 psi fb/Fb' = 0.89
Dead Defl'n 0.11 = < L/999
Live Defl'n 0.33 = L/651 0.60 = L/360 in 0.55
Total Defl'n 0.44 = L/488 0.90 = L/240 in 0.49
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
WoodWorks® Sizer 2019 (Update 4)2_2 Floor Joist Page 2
Additional Data:
FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC#
Fv' 145 1.00 1.00 1.00 - - - - 1.00 1.00 2
Fb'+ 1000 1.00 1.00 1.00 1.000 1.000 - 1.15 1.00 1.00 2
Fcp' 405 - 1.00 1.00 - - - - 1.00 1.00 -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 2
Emin' 0.58 million 1.00 1.00 - - - - 1.00 1.00 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D + L
Bending(+): LC #2 = D + L
Deflection: LC #2 = D + L (live)
LC #2 = D + L (total)
Bearing : Support 1 – LC #2 = D + L
Support 2 – LC #2 = D + L
D=dead L=live
All LC's are listed in the Analysis output
Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1
CALCULATIONS:
V max = 600, V design = 535 lbs; M(+) = 2700 lbs-ft
EIy = 284.76 lb-in^2
"Live" deflection is due to all non-dead loads (live, wind, snow…)
Total deflection = 0.5 dead + "live"
Design Notes:
1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design
Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
Robinett Plan 3083
2_5 GLB
Aug. 4, 2022 15:07
Design Check Calculation Sheet
WoodWorks Sizer 2019 (Update 4)
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
DL Dead Full UDL 585.0 plf
LL Live Full UDL 320.0 plf
SL Snow Full UDL 875.0 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
23'-5.21"
23'0'
Unfactored:
Dead 6854 6854
Live 3749 3749
Snow 10252 10252
Factored:
Total 17356 17356
Bearing:
Capacity
Beam 17356 17356
Support 17910 17910
Des ratio
Beam 1.00 1.00
Support 0.97 0.97
Load comb #3 #3
Length 5.21 5.21
Min req'd 5.21 5.21
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.07 1.07
Fcp sup 625 625
Glulam-Unbalan., West Species, 24F-1.8E WS, 5-1/8"x25-1/2"
Supports: All - Timber-soft Beam, D.Fir-L (N) No.2
Total length: 23'-5.19"; Clear span: 22'-6.81"; Volume = 21.3 cu.ft.; 17 laminations, 5-1/8" maximum width,
Lateral support: top = continuous, bottom = at supports;
This section PASSES the design code check.
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
WoodWorks® Sizer 2019 (Update 4)2_5 GLB Page 2
Analysis vs. Allowable Stress and Deflection using NDS 2018 :
Criterion Analysis Value Design Value Unit Analysis/Design
Shear fv = 156 Fv' = 305 psi fv/Fv' = 0.51
Bending(+) fb = 2116 Fb' = 2536 psi fb/Fb' = 0.83
Dead Defl'n 0.29 = L/955
Live Defl'n 0.44 = L/623 0.77 = L/360 in 0.58
Total Defl'n 0.73 = L/377 1.15 = L/240 in 0.64
Additional Data:
FACTORS: F/E(psi) CD CM Ct CL CV Cfu Cr Cfrt Notes Cvr LC#
Fv' 265 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 3
Fb'+ 2400 1.15 1.00 1.00 1.000 0.919 - - 1.00 1.00 - 3
Fcp' 650 - 1.00 1.00 - - - - 1.00 - - -
E' 1.8 million 1.00 1.00 - - - - 1.00 - - 3
Eminy' 0.85 million 1.00 1.00 - - - - 1.00 - - 3
CRITICAL LOAD COMBINATIONS:
Shear : LC #3 = D + 0.75(L + S)
Bending(+): LC #3 = D + 0.75(L + S)
Deflection: LC #3 = D + 0.75(L + S) (live)
LC #3 = D + 0.75(L + S) (total)
Bearing : Support 1 – LC #3 = D + 0.75(L + S)
Support 2 – LC #3 = D + 0.75(L + S)
D=dead L=live S=snow
All LC's are listed in the Analysis output
Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1
CALCULATIONS:
V max = 17034, V design = 13565 lbs; M(+) = 97948 lbs-ft
EIy = 12746 lb-in^2
"Live" deflection is due to all non-dead loads (live, wind, snow…)
Total deflection = 0.5 dead + "live"
Design Notes:
1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design
Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Glulam design values are for materials conforming to ANSI 117-2015 and manufactured in accordance with ANSI
A190.1-2012
4. GLULAM: bxd = actual breadth x actual depth.
5. Glulam Beams shall be laterally supported according to the provisions of NDS Clause 3.3.3.
6. GLULAM: bearing length based on smaller of Fcp(tension), Fcp(comp'n).
Robinett Plan 3083
2_6 GLB
Aug. 4, 2022 15:16
Design Check Calculation Sheet
WoodWorks Sizer 2019 (Update 4)
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
DL Dead Full UDL 240.0 plf
LL Live Full UDL 480.0 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
16'-1.74"
16'0'
Unfactored:
Dead 1937 1937
Live 3875 3875
Factored:
Total 5812 5812
Bearing:
Capacity
Beam 5812 5812
Support 5998 5998
Des ratio
Beam 1.00 1.00
Support 0.97 0.97
Load comb #2 #2
Length 1.74 1.74
Min req'd 1.74 1.74
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.07 1.07
Fcp sup 625 625
Glulam-Unbalan., West Species, 24F-1.8E WS, 5-1/8"x12"
Supports: All - Timber-soft Beam, D.Fir-L (N) No.2
Total length: 16'-1.75"; Clear span: 15'-10.25"; Volume = 6.9 cu.ft.; 8 laminations, 5-1/8" maximum width,
Lateral support: top = continuous, bottom = at supports;
This section PASSES the design code check.
Analysis vs. Allowable Stress and Deflection using NDS 2018 :
Criterion Analysis Value Design Value Unit Analysis/Design
Shear fv = 122 Fv' = 265 psi fv/Fv' = 0.46
Bending(+) fb = 2248 Fb' = 2400 psi fb/Fb' = 0.94
Dead Defl'n 0.13 = < L/999
Live Defl'n 0.53 = L/360 0.53 = L/360 in 1.00
Total Defl'n 0.67 = L/288 0.80 = L/240 in 0.83
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
WoodWorks® Sizer 2019 (Update 4)2_6 GLB Page 2
Additional Data:
FACTORS: F/E(psi) CD CM Ct CL CV Cfu Cr Cfrt Notes Cvr LC#
Fv' 265 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fb'+ 2400 1.00 1.00 1.00 1.000 1.000 - - 1.00 1.00 - 2
Fcp' 650 - 1.00 1.00 - - - - 1.00 - - -
E' 1.8 million 1.00 1.00 - - - - 1.00 - - 2
Eminy' 0.85 million 1.00 1.00 - - - - 1.00 - - 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D + L
Bending(+): LC #2 = D + L
Deflection: LC #2 = D + L (live)
LC #2 = D + L (total)
Bearing : Support 1 – LC #2 = D + L
Support 2 – LC #2 = D + L
D=dead L=live
All LC's are listed in the Analysis output
Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1
CALCULATIONS:
V max = 5760, V design = 4988 lbs; M(+) = 23040 lbs-ft
EIy = 1328.38 lb-in^2
"Live" deflection is due to all non-dead loads (live, wind, snow…)
Total deflection = 0.5 dead + "live"
Design Notes:
1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design
Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Glulam design values are for materials conforming to ANSI 117-2015 and manufactured in accordance with ANSI
A190.1-2012
4. GLULAM: bxd = actual breadth x actual depth.
5. Glulam Beams shall be laterally supported according to the provisions of NDS Clause 3.3.3.
6. GLULAM: bearing length based on smaller of Fcp(tension), Fcp(comp'n).
Robinett Plan 3083
2_7 Beam
Aug. 4, 2022 15:42
Design Check Calculation Sheet
WoodWorks Sizer 2019 (Update 4)
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
DL Dead Full UDL 280.0 plf
LL Live Full UDL 560.0 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
7'-1.37"
7'0'
Unfactored:
Dead 996 996
Live 1992 1992
Factored:
Total 2988 2988
Bearing:
Capacity
Beam 2988 2988
Support 3308 3308
Des ratio
Beam 1.00 1.00
Support 0.90 0.90
Load comb #2 #2
Length 1.37 1.37
Min req'd 1.37 1.37
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.11 1.11
Fcp sup 625 625
Lumber-soft, D.Fir-L (N), No.1/No.2, 4x12 (3-1/2"x11-1/4")
Supports: All - Timber-soft Beam, D.Fir-L (N) No.2
Total length: 7'-1.38"; Clear span: 6'-10.63"; Volume = 1.9 cu.ft.
Lateral support: top = continuous, bottom = at supports;
This section PASSES the design code check.
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
WoodWorks® Sizer 2019 (Update 4)2_7 Beam Page 2
Analysis vs. Allowable Stress and Deflection using NDS 2018 :
Criterion Analysis Value Design Value Unit Analysis/Design
Shear fv = 80 Fv' = 180 psi fv/Fv' = 0.45
Bending(+) fb = 836 Fb' = 935 psi fb/Fb' = 0.89
Dead Defl'n 0.01 = < L/999
Live Defl'n 0.05 = < L/999 0.23 = L/360 in 0.20
Total Defl'n 0.06 = < L/999 0.35 = L/240 in 0.16
Additional Data:
FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC#
Fv' 180 1.00 1.00 1.00 - - - - 1.00 1.00 2
Fb'+ 850 1.00 1.00 1.00 1.000 1.100 - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 2
Emin' 0.58 million 1.00 1.00 - - - - 1.00 1.00 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D + L
Bending(+): LC #2 = D + L
Deflection: LC #2 = D + L (live)
LC #2 = D + L (total)
Bearing : Support 1 – LC #2 = D + L
Support 2 – LC #2 = D + L
D=dead L=live
All LC's are listed in the Analysis output
Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1
CALCULATIONS:
V max = 2940, V design = 2105 lbs; M(+) = 5145 lbs-ft
EIy = 664.44 lb-in^2
"Live" deflection is due to all non-dead loads (live, wind, snow…)
Total deflection = 0.5 dead + "live"
Design Notes:
1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design
Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
Robinett Plan 3083
2_8 Garage Header
Aug. 4, 2022 15:41
Design Check Calculation Sheet
WoodWorks Sizer 2019 (Update 4)
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
DL Dead Full UDL 60.0 plf
SL Snow Full UDL 160.0 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
16'-0.51"
16'0'
Unfactored:
Dead 481 481
Snow 1283 1283
Factored:
Total 1765 1765
Bearing:
Capacity
Beam 1765 1765
Support 1885 1885
Des ratio
Beam 1.00 1.00
Support 0.94 0.94
Load comb #2 #2
Length 0.51 0.51
Min req'd 0.51 0.51
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.07 1.07
Fcp sup 625 625
Timber-soft, D.Fir-L (N), No.2, 6x12 (5-1/2"x11-1/2")
Supports: All - Timber-soft Beam, D.Fir-L (N) No.2
Total length: 16'-0.5"; Clear span: 15'-11.5"; Volume = 7.0 cu.ft.; Beam or stringer
Lateral support: top = at supports, bottom = at supports;
This section PASSES the design code check.
Analysis vs. Allowable Stress and Deflection using NDS 2018 :
Criterion Analysis Value Design Value Unit Analysis/Design
Shear fv = 37 Fv' = 195 psi fv/Fv' = 0.19
Bending(+) fb = 697 Fb' = 991 psi fb/Fb' = 0.70
Dead Defl'n 0.10 = < L/999
Live Defl'n 0.26 = L/737 0.53 = L/360 in 0.49
Total Defl'n 0.36 = L/536 0.80 = L/240 in 0.45
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
WoodWorks® Sizer 2019 (Update 4)2_8 Garage Header Page 2
Additional Data:
FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC#
Fv' 170 1.15 1.00 1.00 - - - - 1.00 1.00 2
Fb'+ 875 1.15 1.00 1.00 0.985 1.000 - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 -
E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 2
Emin' 0.47 million 1.00 1.00 - - - - 1.00 1.00 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D + S
Bending(+): LC #2 = D + S
Deflection: LC #2 = D + S (live)
LC #2 = D + S (total)
Bearing : Support 1 – LC #2 = D + S
Support 2 – LC #2 = D + S
D=dead S=snow
All LC's are listed in the Analysis output
Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1
CALCULATIONS:
V max = 1760, V design = 1544 lbs; M(+) = 7040 lbs-ft
EIy = 906.17 lb-in^2
"Live" deflection is due to all non-dead loads (live, wind, snow…)
Total deflection = 1.0 dead + "live"
Lateral stability(+): Lu = 16' Le = 29'-5.25" RB = 11.6
Design Notes:
1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design
Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
Robinett Plan 3083
2_9 Beam
Aug. 4, 2022 17:08
Design Check Calculation Sheet
WoodWorks Sizer 2019 (Update 4)
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
DL Dead Full UDL 90.0 plf
SL Snow Full UDL 230.0 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
16'-0.75"
16'0'
Unfactored:
Dead 723 723
Snow 1847 1847
Factored:
Total 2570 2570
Bearing:
Capacity
Beam 2570 2570
Support 2745 2745
Des ratio
Beam 1.00 1.00
Support 0.94 0.94
Load comb #2 #2
Length 0.75 0.75
Min req'd 0.75 0.75
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.07 1.07
Fcp sup 625 625
Timber-soft, D.Fir-L (N), No.2, 6x12 (5-1/2"x11-1/2")
Supports: All - Timber-soft Beam, D.Fir-L (N) No.2
Total length: 16'-0.75"; Clear span: 15'-11.25"; Volume = 7.1 cu.ft.; Beam or stringer
Lateral support: top = continuous, bottom = at supports;
This section FAILS the design check
WARNING: This section violates the following design criteria: Bending
Analysis vs. Allowable Stress and Deflection using NDS 2018 :
Criterion Analysis Value Design Value Unit Analysis/Design
Shear fv = 53 Fv' = 195 psi fv/Fv' = 0.27
Bending(+) fb = 1014 Fb' = 1006 psi fb/Fb' = 1.01
Dead Defl'n 0.15 = < L/999
Live Defl'n 0.37 = L/513 0.53 = L/360 in 0.70
Total Defl'n 0.52 = L/368 0.80 = L/240 in 0.65
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
WoodWorks® Sizer 2019 (Update 4)2_9 Beam Page 2
Additional Data:
FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC#
Fv' 170 1.15 1.00 1.00 - - - - 1.00 1.00 2
Fb'+ 875 1.15 1.00 1.00 1.000 1.000 - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 -
E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 2
Emin' 0.47 million 1.00 1.00 - - - - 1.00 1.00 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D + S
Bending(+): LC #2 = D + S
Deflection: LC #2 = D + S (live)
LC #2 = D + S (total)
Bearing : Support 1 – LC #2 = D + S
Support 2 – LC #2 = D + S
D=dead S=snow
All LC's are listed in the Analysis output
Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1
CALCULATIONS:
V max = 2560, V design = 2243 lbs; M(+) = 10240 lbs-ft
EIy = 906.17 lb-in^2
"Live" deflection is due to all non-dead loads (live, wind, snow…)
Total deflection = 1.0 dead + "live"
Design Notes:
1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design
Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
Robinett Plan 3083
2_10 Beam
Aug. 4, 2022 17:15
Design Check Calculation Sheet
WoodWorks Sizer 2019 (Update 4)
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
DL Dead Full UDL 185.0 plf
LL Live Full UDL 120.0 plf
SL Snow Full UDL 120.0 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
13'-0.69"
13'0'
Unfactored:
Dead 1208 1208
Live 783 783
Snow 783 783
Factored:
Total 2383 2383
Bearing:
Capacity
Beam 2383 2383
Support 2546 2546
Des ratio
Beam 1.00 1.00
Support 0.94 0.94
Load comb #3 #3
Length 0.69 0.69
Min req'd 0.69 0.69
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.07 1.07
Fcp sup 625 625
Timber-soft, D.Fir-L (N), No.2, 6x12 (5-1/2"x11-1/2")
Supports: All - Timber-soft Beam, D.Fir-L (N) No.2
Total length: 13'-0.69"; Clear span: 12'-11.31"; Volume = 5.7 cu.ft.; Beam or stringer
Lateral support: top = continuous, bottom = at supports;
This section PASSES the design code check.
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
WoodWorks® Sizer 2019 (Update 4)2_10 Beam Page 2
Analysis vs. Allowable Stress and Deflection using NDS 2018 :
Criterion Analysis Value Design Value Unit Analysis/Design
Shear fv = 48 Fv' = 195 psi fv/Fv' = 0.24
Bending(+) fb = 763 Fb' = 1006 psi fb/Fb' = 0.76
Dead Defl'n 0.13 = < L/999
Live Defl'n 0.13 = < L/999 0.43 = L/360 in 0.29
Total Defl'n 0.26 = L/602 0.65 = L/240 in 0.40
Additional Data:
FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC#
Fv' 170 1.15 1.00 1.00 - - - - 1.00 1.00 3
Fb'+ 875 1.15 1.00 1.00 1.000 1.000 - 1.00 1.00 1.00 3
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 -
E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 3
Emin' 0.47 million 1.00 1.00 - - - - 1.00 1.00 3
CRITICAL LOAD COMBINATIONS:
Shear : LC #3 = D + 0.75(L + S)
Bending(+): LC #3 = D + 0.75(L + S)
Deflection: LC #3 = D + 0.75(L + S) (live)
LC #3 = D + 0.75(L + S) (total)
Bearing : Support 1 – LC #3 = D + 0.75(L + S)
Support 2 – LC #3 = D + 0.75(L + S)
D=dead L=live S=snow
All LC's are listed in the Analysis output
Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1
CALCULATIONS:
V max = 2373, V design = 2012 lbs; M(+) = 7711 lbs-ft
EIy = 906.17 lb-in^2
"Live" deflection is due to all non-dead loads (live, wind, snow…)
Total deflection = 0.5 dead + "live"
Design Notes:
1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design
Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
Robinett Plan 3083
2_11 Header
Aug. 4, 2022 19:47
Design Check Calculation Sheet
WoodWorks Sizer 2019 (Update 4)
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
DL Dead Full UDL 595.0 plf
LL Live Full UDL 400.0 plf
SL Snow Full UDL 895.0 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
6'-1.39"
6'0'
Unfactored:
Dead 1820 1820
Live 1223 1223
Snow 2737 2737
Factored:
Total 4790 4790
Bearing:
Capacity
Beam 4790 4790
Support 5116 5116
Des ratio
Beam 1.00 1.00
Support 0.94 0.94
Load comb #3 #3
Length 1.39 1.39
Min req'd 1.39 1.39
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.07 1.07
Fcp sup 625 625
Timber-soft, D.Fir-L (N), No.2, 6x12 (5-1/2"x11-1/2")
Supports: All - Timber-soft Beam, D.Fir-L (N) No.2
Total length: 6'-1.38"; Clear span: 5'-10.63"; Volume = 2.7 cu.ft.; Beam or stringer
Lateral support: top = at supports, bottom = at supports;
This section PASSES the design code check.
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
WoodWorks® Sizer 2019 (Update 4)2_11 Header Page 2
Analysis vs. Allowable Stress and Deflection using NDS 2018 :
Criterion Analysis Value Design Value Unit Analysis/Design
Shear fv = 74 Fv' = 195 psi fv/Fv' = 0.38
Bending(+) fb = 698 Fb' = 1001 psi fb/Fb' = 0.70
Dead Defl'n 0.02 = < L/999
Live Defl'n 0.03 = < L/999 0.20 = L/360 in 0.16
Total Defl'n 0.05 = < L/999 0.30 = L/240 in 0.17
Additional Data:
FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC#
Fv' 170 1.15 1.00 1.00 - - - - 1.00 1.00 3
Fb'+ 875 1.15 1.00 1.00 0.994 1.000 - 1.00 1.00 1.00 3
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 -
E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 3
Emin' 0.47 million 1.00 1.00 - - - - 1.00 1.00 3
CRITICAL LOAD COMBINATIONS:
Shear : LC #3 = D + 0.75(L + S)
Bending(+): LC #3 = D + 0.75(L + S)
Deflection: LC #3 = D + 0.75(L + S) (live)
LC #3 = D + 0.75(L + S) (total)
Bearing : Support 1 – LC #3 = D + 0.75(L + S)
Support 2 – LC #3 = D + 0.75(L + S)
D=dead L=live S=snow
All LC's are listed in the Analysis output
Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1
CALCULATIONS:
V max = 4699, V design = 3107 lbs; M(+) = 7048 lbs-ft
EIy = 906.17 lb-in^2
"Live" deflection is due to all non-dead loads (live, wind, snow…)
Total deflection = 0.5 dead + "live"
Lateral stability(+): Lu = 6' Le = 12'-4.31" RB = 7.5
Design Notes:
1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design
Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
Robinett Plan 3083
2_12 Header
Aug. 4, 2022 20:07
Design Check Calculation Sheet
WoodWorks Sizer 2019 (Update 4)
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
DL Dead Full UDL 270.0 plf
LL Live Full UDL 320.0 plf
SL Snow Full UDL 80.0 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
7'-0.95"
7'0'
Unfactored:
Dead 956 956
Live 1133 1133
Snow 283 283
Factored:
Total 2088 2088
Bearing:
Capacity
Beam 2088 2088
Support 2312 2312
Des ratio
Beam 1.00 1.00
Support 0.90 0.90
Load comb #2 #2
Length 0.95 0.95
Min req'd 0.95 0.95
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.11 1.11
Fcp sup 625 625
Lumber-soft, D.Fir-L (N), No.1/No.2, 4x10 (3-1/2"x9-1/4")
Supports: All - Timber-soft Beam, D.Fir-L (N) No.2
Total length: 7'-0.94"; Clear span: 6'-11.06"; Volume = 1.6 cu.ft.
Lateral support: top = at supports, bottom = at supports;
This section PASSES the design code check.
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
WoodWorks® Sizer 2019 (Update 4)2_12 Header Page 2
Analysis vs. Allowable Stress and Deflection using NDS 2018 :
Criterion Analysis Value Design Value Unit Analysis/Design
Shear fv = 74 Fv' = 180 psi fv/Fv' = 0.41
Bending(+) fb = 869 Fb' = 1009 psi fb/Fb' = 0.86
Dead Defl'n 0.04 = < L/999
Live Defl'n 0.04 = < L/999 0.23 = L/360 in 0.19
Total Defl'n 0.08 = < L/999 0.35 = L/240 in 0.24
Additional Data:
FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC#
Fv' 180 1.00 1.00 1.00 - - - - 1.00 1.00 2
Fb'+ 850 1.00 1.00 1.00 0.989 1.200 - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 3
Emin' 0.58 million 1.00 1.00 - - - - 1.00 1.00 3
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D + L
Bending(+): LC #2 = D + L
Deflection: LC #2 = D + L (live)
LC #3 = D + 0.75(L + S) (total)
Bearing : Support 1 – LC #2 = D + L
Support 2 – LC #2 = D + L
D=dead L=live S=snow
All LC's are listed in the Analysis output
Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1
CALCULATIONS:
V max = 2065, V design = 1587 lbs; M(+) = 3614 lbs-ft
EIy = 369.34 lb-in^2
"Live" deflection is due to all non-dead loads (live, wind, snow…)
Total deflection = 0.5 dead + "live"
Lateral stability(+): Lu = 7' Le = 13'-8.69" RB = 11.2
Design Notes:
1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design
Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
Robinett Plan 3083
2_13 Header
Aug. 4, 2022 20:18
Design Check Calculation Sheet
WoodWorks Sizer 2019 (Update 4)
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
DL Dead Full UDL 170.0 plf
LL Live Full UDL 120.0 plf
SL Snow Full UDL 80.0 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
5'-0.5"
5'0'
Unfactored:
Dead 429 429
Live 303 303
Snow 202 202
Factored:
Total 807 807
Bearing:
Capacity
Beam 1094 1094
Support 1211 1211
Des ratio
Beam 0.74 0.74
Support 0.67 0.67
Load comb #3 #3
Length 0.50* 0.50*
Min req'd 0.50* 0.50*
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.11 1.11
Fcp sup 625 625
*Minimum bearing length setting used: 1/2" for end supports
Lumber-soft, D.Fir-L (N), No.1/No.2, 4x6 (3-1/2"x5-1/2")
Supports: All - Timber-soft Beam, D.Fir-L (N) No.2
Total length: 5'-0.5"; Clear span: 4'-11.5"; Volume = 0.7 cu.ft.
Lateral support: top = at supports, bottom = at supports;
This section PASSES the design code check.
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
WoodWorks® Sizer 2019 (Update 4)2_13 Header Page 2
Analysis vs. Allowable Stress and Deflection using NDS 2018 :
Criterion Analysis Value Design Value Unit Analysis/Design
Shear fv = 46 Fv' = 180 psi fv/Fv' = 0.25
Bending(+) fb = 616 Fb' = 1105 psi fb/Fb' = 0.56
Dead Defl'n 0.03 = < L/999
Live Defl'n 0.03 = < L/999 0.17 = L/360 in 0.16
Total Defl'n 0.06 = < L/999 0.25 = L/240 in 0.23
Additional Data:
FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC#
Fv' 180 1.00 1.00 1.00 - - - - 1.00 1.00 2
Fb'+ 850 1.00 1.00 1.00 1.000 1.300 - 1.00 1.00 1.00 2
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 3
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D + L
Bending(+): LC #2 = D + L
Deflection: LC #3 = D + 0.75(L + S) (live)
LC #3 = D + 0.75(L + S) (total)
Bearing : Support 1 – LC #3 = D + 0.75(L + S)
Support 2 – LC #3 = D + 0.75(L + S)
D=dead L=live S=snow
All LC's are listed in the Analysis output
Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1
CALCULATIONS:
V max = 725, V design = 586 lbs; M(+) = 906 lbs-ft
EIy = 77.64 lb-in^2
"Live" deflection is due to all non-dead loads (live, wind, snow…)
Total deflection = 0.5 dead + "live"
Design Notes:
1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design
Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
2_14 Post
Aug. 4, 2022 20:31
Design Check Calculation Sheet
WoodWorks Sizer 2019 (Update 4)
Loads:
Load Type Distribution Location [ft] Magnitude Unit
Start End Start End
PDL Dead Axial (Ecc. = 0.00") 6855 lbs
PLL Live Axial (Ecc. = 0.00") 10500 lbs
Reactions (lbs):
9'
9'0'
Ba
s
e
To
p
Unfactored:
Lateral:
Dead
Live
Axial:
Dead 6855 6855
Live 10500 10500
Factored:
L->R
Load comb #1 #1
Timber-soft, D.Fir-L (N), No.2, 6x6 (5-1/2"x5-1/2")
Support: Non-wood
Total length: 9'; Volume = 1.9 cu.ft.; Post or timber
Pinned base; Ke x Lb: 1.0 x 9.0 = 9.0 ft; Ke x Ld: 1.0 x 9.0 = 9.0 ft;
This section FAILS the design check
WARNING: This section violates the following design criteria: Axial
Analysis vs. Allowable Stress and Deflection using NDS 2018 :
Criterion Analysis Value Design Value Unit Analysis/Design
Axial fc = 574 Fc' = 559 psi fc/Fc' = 1.03
Axial Bearing fc = 574 Fc* = 700 psi fc/Fc* = 0.82*
*Column requires a bearing plate at top as per NDS 3.10.1.3
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
WoodWorks® Sizer 2019 (Update 4)2_14 Post Page 2
Additional Data:
FACTORS: F/E(psi) CD CM Ct CL/CP CF Cfu Cr Cfrt Ci LC#
Fc' 700 1.00 1.00 1.00 0.799 1.000 - - 1.00 1.00 2
Fc* 700 1.00 1.00 1.00 - 1.000 - - 1.00 1.00 2
CRITICAL LOAD COMBINATIONS:
Axial : LC #2 = D + L
D=dead L=live
All LC's are listed in the Analysis output
Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1
Design Notes:
1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design
Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
Robinett Plan 3083
3_2 Beam
Aug. 4, 2022 20:48
Design Check Calculation Sheet
WoodWorks Sizer 2019 (Update 4)
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
DL Dead Full UDL No 760.0 plf
LL Live Full UDL Yes 1200.0 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
4'8'
12'-1.6"
12'0'
Unfactored:
Dead 1267 3344 3344 1267
Live 2240 5760 5760 2240
Factored:
Total 3507 9104 9104 3507
Bearing:
Capacity
Beam 3507 9104 9104 3507
Support 3883 9171 9171 3883
Des ratio
Beam 1.00 1.00 1.00 1.00
Support 0.90 0.99 0.99 0.90
Load comb #7 #5 #8 #7
Length 1.60 3.79 3.79 1.60
Min req'd 1.60 3.79 3.79 1.60
Cb 1.00 1.10 1.10 1.00
Cb min 1.00 1.10 1.10 1.00
Cb support 1.11 1.11 1.11 1.11
Fcp sup 625 625 625 625
Lumber-soft, D.Fir-L (N), No.1/No.2, 4x10 (3-1/2"x9-1/4")
Supports: All - Timber-soft Beam, D.Fir-L (N) No.2
Total length: 12'-1.63"; Clear span: 3'-9.31", 3'-8.19", 3'-9.31"; Volume = 2.7 cu.ft.
Lateral support: top = continuous, bottom = at end supports;
This section PASSES the design code check.
Analysis vs. Allowable Stress and Deflection using NDS 2018 :
Criterion Analysis Value Design Value Unit Analysis/Design
Shear fv = 139 Fv' = 180 psi fv/Fv' = 0.77
Bending(+) fb = 699 Fb' = 1020 psi fb/Fb' = 0.69
Bending(-) fb = 831 Fb' = 1000 psi fb/Fb' = 0.83
Dead Defl'n 0.01 = < L/999
Live Defl'n 0.01 = < L/999 0.13 = L/360 in 0.11
Total Defl'n 0.02 = < L/999 0.20 = L/240 in 0.10
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
WoodWorks® Sizer 2019 (Update 4)3_2 Beam Page 2
Additional Data:
FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC#
Fv' 180 1.00 1.00 1.00 - - - - 1.00 1.00 5
Fb'+ 850 1.00 1.00 1.00 1.000 1.200 - 1.00 1.00 1.00 7
Fb'- 850 1.00 1.00 1.00 0.980 1.200 - 1.00 1.00 1.00 5
Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 -
E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 7
Emin' 0.58 million 1.00 1.00 - - - - 1.00 1.00 7
CRITICAL LOAD COMBINATIONS:
Shear : LC #5 = D + L (pattern: LL_)
Bending(+): LC #7 = D + L (pattern: L_L)
Bending(-): LC #5 = D + L (pattern: LL_)
Deflection: LC #7 = D + L (pattern: L_L) (live)
LC #7 = D + L (pattern: L_L) (total)
Bearing : Support 1 – LC #7 = D + L (pattern: L_L)
Support 2 – LC #5 = D + L (pattern: LL_)
Support 3 – LC #8 = D + L (pattern: _LL)
Support 4 – LC #7 = D + L (pattern: L_L)
D=dead L=live
All LC's are listed in the Analysis output
Load Patterns: s=S/2, X=L+S or L+Lr, _=no pattern load in this span
Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1
CALCULATIONS:
V max = 4784, V design = 3003 lbs; M(+) = 2907 lbs-ft; M(-) = 3456 lbs-ft
EIy = 369.34 lb-in^2
"Live" deflection is due to all non-dead loads (live, wind, snow…)
Total deflection = 0.5 dead + "live"
Lateral stability(-): Lu = 12' Le = 22'-0.94" RB = 14.1; Lu based on full span
Design Notes:
1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design
Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the
middle 2/3 of 2 span beams and to the full length of cantilevers and other spans.
4. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
This message is from an External Sender
This message came from outside the City of Arlington
From:Sarah Uplinger
To:Kristin Foster
Subject:Re: Bridgemont SFR Review Comments
Date:Wednesday, October 18, 2023 1:04:01 PM
Attachments:image001.png
3038 Bridgemont Lot 15.pdf
2808A Bridgemont Lot 10.pdf
Oops somehow these 2 did not come through on the first email
- Sarah Uplinger
425-490-2205 Office
425-490-2206 FaxMy office hours are Monday -Thursday 7am-3pm
On Wed, Oct 18, 2023 at 12:57 PM Sarah Uplinger <sarah@robinetthomes.com> wrote:
Attached are new site plans for lots 3,5,7,8,9,10,11, 15 and 17.
The blank walls of windows are on the side of structures which will be blocked bythe structures adjacent. The walls of lots 1 & 18 which face the 186th St NE havebeen revised and will be submitted when those permits are ready for submission(later this week).
Hopefully that addresses the initial comments, I will be bringing physical copies of
these site plans along with the new permit submissions to the office tomorrow.
- Sarah Uplinger
425-490-2205 Office425-490-2206 FaxMy office hours are Monday -Thursday 7am-3pm
On Thu, Jul 20, 2023 at 9:04 AM Kristin Foster <kfoster@arlingtonwa.gov> wrote:
Good Morning,
Please see below review comments regarding the submittals we received for the single-
family homes. These comments apply to all plans (A, B and Gable). Please revise plans
accordingly per comments 1 and 2. Links to Arlington Municipal Code and the
Development Design Standards are provided below. Comment 3 is for your information
and will be conditioned on the building permit.
1. The single-family homes are subject to the Development Design Standards (DDS) per
AMC 20.46.010(a)(1).
2. No blank walls are allowed per DDS 2.2.3(a)(b) and 11.2.3.4. Please amend the right
side of the structures.
3. No service elements were shown on the plans. Service elements are not allowed on the
facade of the structure. All electrical (PUD), heating units, AC units, etc. are to be placed
on the side or rear of the structure.
AMC 20.46
Chapter-2046-Design (arlingtonwa.gov)
Development Design Standards
Development-Design-Standards (arlingtonwa.gov)
Feel free to reach out should you have any questions.
Regards,
Kristin Foster
Permit Technician
City of Arlington
Community & Economic Development
18204 59th Ave NE
Arlington, WA 98223
Office: 360-403-3545
www.arlingtonwa.gov