Loading...
HomeMy WebLinkAbout7530 204th St Ne_BLD6118_2025 Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551 Page 1 of 1 Permit Number: Permit Type: Address/Parcel: Completed (Month/Year): Land Use ˆ Notice of Decision ˆ Staff Report ˆ Application ˆ Narrative ˆ Legal Description ˆ Vicinity Map ˆ Site Plan ˆ Landscape Plan ˆ Complete Streets Checklist ˆ Traffic Impact Analysis ˆ Snohomish County Traffic Mitigation Offer ˆ WSDOT Traffic Offer Form ˆ Tree Survey ˆ Stormwater Drainage Report ˆ Geotech Report ˆ Critical Area Evaluation Form ˆ SEPA Checklist ˆ Public Notice Material ˆ Noticing and Related Documents ˆ Water / Sewer Availability Certificate ˆ Unanticipated Discovery Plan Form ˆ Aerial Photo of Site ˆ Proposed Building Materials ˆ Lighting Plans and Lighting Cut Sheets ˆ Color Elevations ˆ Design Matrix ˆ Plat Map ˆ Title Report ˆ Lot Closures ˆ Preliminary Civil Plans ˆ Archaeological Survey o Confidential Documents. Contact the City to obtain. ˆ Topography (Existing Conditions) ˆ CC&R’s ˆ Deeds / Easements / Conveyances /Dedications ˆ Developer’s Agreement ˆ Recorded Copies ˆ Bonding or Assignment of Funds o Confidential Documents. Contact the City to obtain. ˆ Letters and Project Documents ˆ Other: Civil ˆ Issued Permit ˆ Application ˆ Other Applications ˆ Construction Calculation Worksheet ˆ Approved Plans ˆ Review Comment Form ˆ Letters and Project Documents ˆ Other Agency Permits ˆ Reports: o Drainage Report Pg: o Stormwater Pg: o Geotech Pg: o All Other Reports ˆ SEPA and Noticing Materials ˆ Inspections ˆ As-Builts ˆ Other: Building ˆ Issued Permit ˆ Application ˆ Additional Applications ˆ Approved Plans ˆ Site Plan ˆ Letters and Project Documents ˆ Calculations ˆ Project Specification Manuals ˆ Reports ˆ Certificate of Occupancy ˆ Inspections ˆ Other: BLD6118 Demolition 7530 204th St Ne December 2024 ✔ ✔ ✔ ✔ ✔ ✔ CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 B UILDING PERM IT 7530 204TH ST NE Parcel #: 31051400100600 Pe rmit #: 6118 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work: Remove existing building, surface lots, utilities, trees on south / west property line (except large douglas fir) per plans for the new wet rabbit car wash plans. Valuation: 38525.00 OWNER APPLICANT CONTRACTOR CHAFFEE CHARLES T & ELLEN Wet Rabbit Car Wash Saybr Contractors, Inc 7530 204TH ST NE 1219 State Ave 3852 S 66th St ARLINGTON, WA 98223-8912 Marysville, WA 98270 Tacoma, WA 98409 206-284-8200 253-533-2382 LIC: 601 795 367 EXP: 08/31/2025 LIC: SAYBRCI033L7 EXP: 06/30/2026 MECHANICAL CONTRACTOR PLUMB ING CONTRACTOR LIC #:EXP:LIC #:EXP: JOB DESCRIPTION PERMIT TYPE:DEMOLITION CODE YEAR:2021 STORIES:1 CONST. TYP E:VB DWELLING UNITS:OCC GROUP :B; Business BUILDINGS:OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO P ERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A P ERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEP UTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 08/22/2024 Applicant Signature Date Building Official Date CONDITIONS Adhere to Puget Sound Clean Air Procedures and Guidelines. The existing sewer line shall be cut and capped prior to demolition and shall be inspected by the wastewater department. Contact the City of Arlington Public Works Department at 360-435-3526 for notification of demolition for water and wastewater inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS P ERMIT COVERS WORK TO BE DONE ON P RIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date De s cription Fe e Amount 08/26/2024 Web Only - Demolition $100.00 08/26/2024 Credit Card Service $3.00 08/26/2024 Processing/Technology $25.00 08/26/2024 Inspection $75.00 Total Due :$203.00 Total Payme nt:$203.00 B alance Due :$0.00 CALL FOR INSPECTIONS Call by 3:30 pm for ne xt day ins pe ction, allow 48 hours for Fire Ins pe ctions Whe n calling for an ins pe ction ple as e le ave the following information: Pe rmit Numbe r, Type of Ins pe ction be ing re que s te d, and whe the r you pre fe r morning or afte rnoon INSPECTION INFORM ATION Pas s /Fail PO Box 39220 9822 32nd Ave Ct S Lakewood, WA 98499 Phone: 253.588.0440 Fax: 253.588.0198 www.nwabatement.com Asbestos Survey “It’s Not What We Do, It’s How We Do It” Project: Asbestos Survey Previous Medical Office (Proposed Demolition) 7530 204th St NE, Arlington, WA 98223 Prepared For: Wet Rabbit 1219 State Ave, Marysville, WA 98270 Project Number: SR24-4350 SECTION 1 |Inspection Report SECTION 2 |Laboratory Results SECTION 3 |Photographs SECTION 4 |AHERA Certification TABLE OF CONTENTS SECTION 1 |Inspection Report Northwest Abatement Services, Inc. Inspection Report | 1 AHERA Certified Asbestos Survey / Inspection Report 06-11-2024 Prepared For: Wet Rabbit Project: Asbestos Survey Previous Medical Office – (Proposed Demolition) 7530 204th St NE, Arlington, WA 98223 A. Background On 06-06-2024 Northwest Abatement Services, Inc. performed an asbestos identification inspection which will serve as our report for all visible Asbestos Containing Building Materials located on the roof at the address listed above. The purpose of this inspection was to ascertain the presence of asbestos containing materials located in the structure and provide a report to conform to WAC 296-62-077, PSCAA Regulation III, Section 4 and 40 CFR 763 requirements for identification of asbestos. This survey also satisfies regulatory criteria established by OSHA’s Department of Labor and Washington State’s Department of Labor and Industries for identifying asbestos containing materials associated with the structure for future abatement and demolition. A copy of this report may be submitted to the appropriate agencies as proof that a survey was performed prior to any renovation or demolition. A copy of this report should also be given to the contractor and/or be maintained onsite during any abatement and demolition activities. B. Sampling Methodology Suspect materials were sampled by an AHERA (Asbestos Hazard Emergency Response Act) accredited inspector. Sample locations for this survey were chosen in a non-random fashion, with emphasis being placed on obtaining samples of each type of accessible, suspect material, while minimizing damage to the material being sampled. Samples were collected by carefully removing small portions of the suspect material in a non-abrasive manner. If possible, samples were collected from existing damaged areas. Friable materials are materials which can be crushed, pulverized, or reduced to powder by hand pressure. These materials were wetted with amended water prior to sampling to protect the inspector from potential exposure or accidental fiber release. PPE (personal protective clothing) will only be utilized at the inspector’s discretion. A particular suspect material may be located in various separate places throughout the structure. The EPA does not require that these materials be sampled in each location. Suspect materials of the same type, age, appearance have the same date of installation, and are sampled in accordance with AHERA requirements, must provide statistically reliable data which can be extrapolated on all remaining non sampled areas. AHERA Protocol determines the number of samples of each material to be collected, depending on it’s category and amount of material present. The goal of AHERA is to ensure statistically reliable data and it accomplishes this by requiring or suggesting a minimum number of samples to be collected, and in some cases, by using random sampling techniques to determine sampling locations. However, in every case, AHERA relies on the judgment of the inspectors who are experienced in AHERA methodology and the type of facilities being inspected. (see appendix A at end of the report) After identifying the suspect materials, bulk samples were collected and taken to an asbestos laboratory to be analyzed for the amount of asbestos and, the type of asbestos, if any. The asbestos samples were analyzed using Polarized Light Microscopy (PLM), stain dispersion staining techniques in accordance with the EPA Method 600/R-93/166, which has a reliable limit of quantification of one percent asbestos by volume. Northwest Abatement Services, Inc. Inspection Report | 2 C. AHERA Certified Inspector Information The Certified AHERA Inspector was Paul Peters. Certification #: BI/R-NES-10-20-23-03, Expiration 10-20-2024 D. Survey Findings There was a total of thirty-nine suspect asbestos containing building materials (bulk samples), removed from the structure listed above, for lab analysis. Based on the field inspection, homogenization of materials, and the results of the lab analysis, Zero of the thirty-nine samples tested Positive for Asbestos: Sample Number Material Asbestos Content Quantity Northwest Abatement Services, Inc. Inspection Report | 3 E. Building Description The commercial structure is located at – 7530 204th St NE, Arlington, WA 98223 The commercial structure has description of – Finished walls, acoustic tile ceilings, luxury vinyl plank, vinyl sheet and vinyl composition tile flooring throughout. Note: All suspect ACM finishes were sampled and tested according to AHERA Protocol. (See appendix A) The suspect ACM (asbestos containing materials) sampled for analysis are as follows: Sample Number Material Location 1 Wallboard Front Entry Waiting Room 1A Joint Compound Front Entry Waiting Room 1B Texture Front Entry Waiting Room 2 Wallboard Waiting Room Cove 2A Joint Compound Waiting Room Cove 2B Texture Waiting Room Cove 3 Wallboard Front Right Office 3A Joint Compound Front Right Office 3B Texture Front Right Office 4 Wallboard Rear Entry 4A Joint Compound Rear Entry 4B Texture Rear Entry 5 Wallboard Rear Middle Office 5A Joint Compound Rear Middle Office 5B Texture Rear Middle Office 6 Wallboard Left Middle Office 6A Joint Compound Left Middle Office 6B Texture Left Middle Office 7 Wallboard Center Office 7A Joint Compound Center Office 7B Texture Center Office 8 Vinyl Sheet Rear Entry 8A Mastic Rear Entry 9 Luxury Vinyl Plank Rear Entry 10 Vinyl Sheet Rear Right Bathroom 10A Mastic Rear Right Bathroom 11 Mastic, Cove Base Rear Middle Office 12 Vinyl Sheet Rear Middle Office 12A Mastic Rear Middle Office 13 Mastic, Cove Base Left Side Hall 14 Vinyl Sheet Front Left Bathroom 14A Mastic Front Left Bathroom 15 Vinyl Sheet Front Utility Room 15A Mastic Front Utility Room 16 Ceiling Tile Waiting Room 17 Asphalt Shingle South Roof Shingle 18 Roof Core Central Roof Northwest Abatement Services, Inc. Inspection Report | 4 19 Roof Core South Roof 20 Roof Core North Roof Northwest Abatement Services, Inc. Inspection Report | 5 F. Conclusion Laboratory results did not show any asbestos in the samples tested. No abatement is required unless discovery of suspect materials. Prior to any demolition or renovation, all friable and non-friable asbestos containing materials (ACM) are to be removed and disposed of in accordance with applicable Federal, State and Local regulations. If there is any asbestos containing materials left on site, that will not be disturbed during the renovation or demolition process, an Asbestos Operational and Maintenance Program (OM) is to be developed and implemented to monitor the remaining ACM. In the event any suspect materials are detected during the demolition of this structure, you will need to cease all demolition activities and have these materials sampled for Asbestos. The Puget Sound Clean Air Authority requires that all materials that contain 1% or more Asbestos, that these materials be removed by a licensed and Certified Asbestos removal contractor, prior to any demolition or renovation. The abatement contractor should provide the Owner with copies of all required notifications to PSCAA and the Department of Labor and Industries. A certification letter will need to be obtained from the abatement contractor prior to applying for a demolition permit with PSCAA. PSCAA will also want to see a copy of the asbestos survey. Although extreme thoroughness and expertise were exercised to ensure the completeness of this survey, existing conditions may have prevented the discovery of other suspect asbestos containing material. NW Abatement Services, Inc. is not responsible for materials that may be hidden from sight and cannot be discovered with reasonable diligence. Any suspect material not covered in this survey that is encountered during the renovation or demolition procedure should be verified by analysis prior to disturbance. This report has been prepared for the sole use of our client and its representatives for this project only. The analyses, conclusions and recommendations presented in this report are based upon conditions encountered at the time of our survey only. The scope of services performed during this survey may not be appropriate for the needs of others. Re-use of this document or the findings, conclusions or recommendations presented herein, are at the sole risk of said user. NW Abatement Services, Inc. cannot be held responsible for the interpretation by others of the data contained in this report. The conclusions presented in this report were based on the results of sample analysis presented by a subcontracted, third party, analytical laboratory. Northwest Abatement Services, Inc. is not responsible for variations in analytical results or inaccuracies resulting from laboratory analysis. This survey is not intended for use as abatement plans and/or specifications. Northwest Abatement Services, Inc. recommends that professional plans and specifications be prepared for all large-scale projects. No warranty, expressed or implied, is made. If you have any questions regarding this asbestos survey/inspection report, please contact us at (253) 588-0440, or FAX: (253) 588-0198. Respectfully submitted, Paul Peters Paul Peters Certified AHERA Inspector NORTHWEST ABATEMENT SERVICES, INC. Northwest Abatement Services, Inc. Inspection Report | 6 Appendix A The following AHERA protocol was used in determining the number of suspect samples to collect: Surfacing materials: 1) Homogeneous area equal to or less than 1000 SF (minimum 3 samples). 2) Homogeneous area greater than 1000 SF but less than 5000 SF. (5 samples) 3) Homogeneous area greater than 5000 SF. (7 samples) Thermal Systems Insulation (TSI): 1) Homogeneous area (1 per each type of suspect materials). Miscellaneous materials: 1) Homogeneous area (1 per each type of suspect materials) Suspect Materials are divided into 3 categories: 1) Surfacing materials – ACM sprayed or troweled on surfaces (walls, ceilings, and structural members) for acoustical, decorative, thermal insulation or fireproofing purposes. Examples include plaster, popcorn textured ceilings, skim coat textures, and structural fireproofing. 2) Thermal System Insulation – Insulation used to inhibit heat transfer or prevent condensation on pipes, boilers, tanks, ducts, and various other components of hot and cold water systems, and heating, ventilation, and air conditioning (HVAC) systems. Examples include pipe lagging, pipe wrap; block, batt, and blanket insulation; cement and “muds” and a variety of other products such as gaskets and ropes. 3) Miscellaneous Materials – Materials not classified under surfacing materials or thermal systems insulation. Examples include: floor tile, ceiling tile, roofing felts, concrete piping, outdoor siding and fabrics, glazing putty, wall board and associated assembly component, various mastics, etc. such as floor tile mastics, wall board mastics, ceiling tile mastics etc. SECTION 2 |Laboratory Results SanAir ID#: 24031598 Project #: SR24-4350 Project Name: 7530 204th St NE, Arlington Report Date: 6/10/2024 Analysis Report prepared for Northwest Abatement Services, Inc. Page 1 of 11 Dear Paul Peters, We at SanAir would like to thank you for the work you recently submitted. The 39 sample(s) were received on Friday, June 07, 2024 via UPS. The final report(s) is enclosed for the following sample(s): 1, 1A, 1B, 2, 2A, 2B, 3, 3A, 3B, 4, 4A, 4B, 5, 5A, 5B, 6, 6A, 6B, 7, 7A, 7B, 8, 8A, 9, 10, 10A, 11, 12, 12A, 13, 14, 14A, 15, 15A, 16, 17, 18, 19, 20. These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report. Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory Final Report Includes: - Cover Letter - Analysis Pages - Disclaimers and Additional Information Sample conditions: - 39 samples in Good condition. 10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com SR24-4350Project Number: SR24-4350P.O. Number: Project Name:7530 204th St NE, Arlington 6/6/2024Collected Date: 6/7/2024 10:00:00 AMReceived Date: 6/10/2024 12:20:12 PM 24031598 SanAir ID Number FINAL REPORT Northwest Abatement Services, Inc.Name: Address:P.O. Box 39220 Lakewood, WA 98496 253-588-0440Phone: Page 2 of 11 Analyst: Pisula, Nicholas Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 1 / 24031598-001 Wallboard/Front Entry Waiting Room Grey Non-Fibrous Homogeneous 5% Cellulose 95% Other None Detected 1A / 24031598-002 Joint Compound/Front Entry Waiting Room White Non-Fibrous Homogeneous 100% Other None Detected 1B / 24031598-003 Texture/Front Entry Waiting Room White Non-Fibrous Homogeneous 100% Other None Detected 2 / 24031598-004 Wallboard/Waiting Area Cove Grey Non-Fibrous Homogeneous 5% Cellulose 95% Other None Detected 2A / 24031598-005 Joint Compound/Waiting Area Cove White Non-Fibrous Homogeneous 100% Other None Detected 2B / 24031598-006 Texture/Waiting Area Cove White Non-Fibrous Homogeneous 100% Other None Detected 3 / 24031598-007 Wallboard/Front Right Office Grey Non-Fibrous Homogeneous 5% Cellulose 95% Other None Detected 3A / 24031598-008 Joint Compound/Front Right Office White Non-Fibrous Homogeneous 100% Other None Detected 3B / 24031598-009 Texture/Front Right Office White Non-Fibrous Homogeneous 100% Other None Detected 4 / 24031598-010 Wallboard/Rear Entry Grey Non-Fibrous Homogeneous 5% Cellulose 95% Other None Detected Analyst: Analysis Date:6/10/2024 Date:6/10/2024 Approved Signatory: SR24-4350Project Number: SR24-4350P.O. Number: Project Name:7530 204th St NE, Arlington 6/6/2024Collected Date: 6/7/2024 10:00:00 AMReceived Date: 6/10/2024 12:20:12 PM 24031598 SanAir ID Number FINAL REPORT Northwest Abatement Services, Inc.Name: Address:P.O. Box 39220 Lakewood, WA 98496 253-588-0440Phone: Page 3 of 11 Analyst: Pisula, Nicholas Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 4A / 24031598-011 Joint Compound/Rear Entry White Non-Fibrous Homogeneous 100% Other None Detected 4B / 24031598-012 Texture/Rear Entry White Non-Fibrous Homogeneous 100% Other None Detected 5 / 24031598-013 Wallboard/Rear Middle Office Grey Non-Fibrous Homogeneous 5% Cellulose 95% Other None Detected 5A / 24031598-014 Joint Compound/Rear Middle Office White Non-Fibrous Homogeneous 100% Other None Detected 5B / 24031598-015 Texture/Rear Middle Office White Non-Fibrous Homogeneous 100% Other None Detected 6 / 24031598-016 Wallboard/Left Middle Office Grey Non-Fibrous Homogeneous 5% Cellulose 95% Other None Detected 6A / 24031598-017 Joint Compound/Left Middle Office White Non-Fibrous Homogeneous 100% Other None Detected 6B / 24031598-018 Texture/Left Middle Office White Non-Fibrous Homogeneous 100% Other None Detected 7 / 24031598-019 Wallboard/Center Office Grey Non-Fibrous Homogeneous 5% Cellulose 95% Other None Detected 7A / 24031598-020 Joint Compound/Center Office White Non-Fibrous Homogeneous 100% Other None Detected Analyst: Analysis Date:6/10/2024 Date:6/10/2024 Approved Signatory: 10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com SR24-4350Project Number: SR24-4350P.O. Number: Project Name:7530 204th St NE, Arlington 6/6/2024Collected Date: 6/7/2024 10:00:00 AMReceived Date: 6/10/2024 12:20:12 PM 24031598 SanAir ID Number FINAL REPORT Northwest Abatement Services, Inc.Name: Address:P.O. Box 39220 Lakewood, WA 98496 253-588-0440Phone: Page 4 of 11 Analyst: Pisula, Nicholas Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 7B / 24031598-021 Texture/Center Office White Non-Fibrous Homogeneous 100% Other None Detected 8 / 24031598-022 Vinyl Sheet/Rear Entry Grey Non-Fibrous Homogeneous 100% Other None Detected 8A / 24031598-023 Mastic/Rear Entry Tan Non-Fibrous Homogeneous 100% Other None Detected 9 / 24031598-024 LVP/Rear Entry Grey Non-Fibrous Homogeneous 100% Other None Detected 10 / 24031598-025 Vinyl Sheet/Rear Right Bathroom Grey Non-Fibrous Homogeneous 100% Other None Detected 10A / 24031598-026 Mastic/Rear Right Bathroom Tan Non-Fibrous Homogeneous 100% Other None Detected 11 / 24031598-027 Mastic, Cove Base/Rear Middle Office Tan Non-Fibrous Homogeneous 100% Other None Detected 12 / 24031598-028 Vinyl Sheet/Rear Middle Office Tan Non-Fibrous Homogeneous 100% Other None Detected 12A / 24031598-029 Mastic/Rear Middle Office Tan Non-Fibrous Homogeneous 100% Other None Detected 13 / 24031598-030 Mastic, Cove Base/Left Side Hall Tan Non-Fibrous Homogeneous 100% Other None Detected Analyst: Analysis Date:6/10/2024 Date:6/10/2024 Approved Signatory: 10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com SR24-4350Project Number: SR24-4350P.O. Number: Project Name:7530 204th St NE, Arlington 6/6/2024Collected Date: 6/7/2024 10:00:00 AMReceived Date: 6/10/2024 12:20:12 PM 24031598 SanAir ID Number FINAL REPORT Northwest Abatement Services, Inc.Name: Address:P.O. Box 39220 Lakewood, WA 98496 253-588-0440Phone: Page 5 of 11 Analyst: Pisula, Nicholas Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 14 / 24031598-031 Vinyl Sheet/Front Left Bathroom Grey Non-Fibrous Homogeneous 100% Other None Detected 14A / 24031598-032 Mastic/Front Left Bathroom Tan Non-Fibrous Homogeneous 100% Other None Detected 15 / 24031598-033 Vinyl Sheet/Front Utility Room Beige Non-Fibrous Homogeneous 100% Other None Detected 15A / 24031598-034 Mastic/Front Utility Room Tan Non-Fibrous Homogeneous 100% Other None Detected 16 / 24031598-035 Ceiling Tile/Waiting Room White Fibrous Homogeneous 60% Cellulose 30% Min. Wool 10% Other None Detected 17 / 24031598-036 Asphalt Shingle/South Roof, Shingle Brown Non-Fibrous Heterogeneous 100% Other None Detected 17 / 24031598-036 Asphalt Shingle/South Roof, Shingle Black Non-Fibrous Heterogeneous 100% Other None Detected 17 / 24031598-036 Asphalt Shingle/South Roof, Shingle Brown Non-Fibrous Heterogeneous 100% Other None Detected 17 / 24031598-036 Asphalt Shingle/South Roof, Tar Paper Black Fibrous Homogeneous 60% Cellulose 40% Other None Detected 18 / 24031598-037 Roof Core/Central Roof, Coating Silver Non-Fibrous Homogeneous 100% Other None Detected Analyst: Analysis Date:6/10/2024 Date:6/10/2024 Approved Signatory: 10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com SR24-4350Project Number: SR24-4350P.O. Number: Project Name:7530 204th St NE, Arlington 6/6/2024Collected Date: 6/7/2024 10:00:00 AMReceived Date: 6/10/2024 12:20:12 PM 24031598 SanAir ID Number FINAL REPORT Northwest Abatement Services, Inc.Name: Address:P.O. Box 39220 Lakewood, WA 98496 253-588-0440Phone: Page 6 of 11 Analyst: Pisula, Nicholas Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 18 / 24031598-037 Roof Core/Central Roof, Tar Black Non-Fibrous Homogeneous 100% Other None Detected 18 / 24031598-037 Roof Core/Central Roof, Felt Black Non-Fibrous Homogeneous 20% Glass 80% Other None Detected 18 / 24031598-037 Roof Core/Central Roof, Tar Black Non-Fibrous Homogeneous 100% Other None Detected 18 / 24031598-037 Roof Core/Central Roof, Felt Black Non-Fibrous Homogeneous 20% Glass 80% Other None Detected 18 / 24031598-037 Roof Core/Central Roof, Tar Black Non-Fibrous Homogeneous 100% Other None Detected 19 / 24031598-038 Roof Core/South Roof, Coating Silver Non-Fibrous Homogeneous 100% Other None Detected 19 / 24031598-038 Roof Core/South Roof, Tar Black Non-Fibrous Homogeneous 100% Other None Detected 19 / 24031598-038 Roof Core/South Roof, Felt Black Non-Fibrous Homogeneous 20% Glass 80% Other None Detected 19 / 24031598-038 Roof Core/South Roof, Tar Black Non-Fibrous Homogeneous 100% Other None Detected 19 / 24031598-038 Roof Core/South Roof, Felt Black Non-Fibrous Homogeneous 20% Glass 80% Other None Detected Analyst: Analysis Date:6/10/2024 Date:6/10/2024 Approved Signatory: 10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com SR24-4350Project Number: SR24-4350P.O. Number: Project Name:7530 204th St NE, Arlington 6/6/2024Collected Date: 6/7/2024 10:00:00 AMReceived Date: 6/10/2024 12:20:12 PM 24031598 SanAir ID Number FINAL REPORT Northwest Abatement Services, Inc.Name: Address:P.O. Box 39220 Lakewood, WA 98496 253-588-0440Phone: Page 7 of 11 Analyst: Pisula, Nicholas Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 19 / 24031598-038 Roof Core/South Roof, Tar Black Non-Fibrous Homogeneous 100% Other None Detected 20 / 24031598-039 Roof Core/North Roof, Coating Silver Non-Fibrous Homogeneous 100% Other None Detected 20 / 24031598-039 Roof Core/North Roof, Tar Black Non-Fibrous Homogeneous 100% Other None Detected 20 / 24031598-039 Roof Core/North Roof, Felt Black Non-Fibrous Homogeneous 20% Glass 80% Other None Detected 20 / 24031598-039 Roof Core/North Roof, Tar Black Non-Fibrous Homogeneous 100% Other None Detected 20 / 24031598-039 Roof Core/North Roof, Felt Black Non-Fibrous Homogeneous 20% Glass 80% Other None Detected 20 / 24031598-039 Roof Core/North Roof, Tar Black Non-Fibrous Homogeneous 100% Other None Detected Analyst: Analysis Date:6/10/2024 Date:6/10/2024 Approved Signatory: 10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com SR24-4350Project Number: SR24-4350P.O. Number: Project Name:7530 204th St NE, Arlington 6/6/2024Collected Date: 6/7/2024 10:00:00 AMReceived Date: 6/10/2024 12:20:12 PM 24031598 SanAir ID Number FINAL REPORT Northwest Abatement Services, Inc.Name: Address:P.O. Box 39220 Lakewood, WA 98496 253-588-0440Phone: Page 8 of 11 Disclaimer This report is the sole property of the client named on the SanAir Technologies Laboratory chain- of-custody (COC). Results in the report are confidential information intended only for the use by the customer listed on the COC. Neither results nor reports will be discussed with or released to any third party without our client's written permission. The final report shall not be reproduced except in full without written approval of the laboratory to assure that parts of the report are not taken out of context. This report and any information contained within shall not be edited, altered, or modified in any way by any persons or agencies receiving, viewing, distributing, or otherwise possessing a copy of this final report. The laboratory reserves the right to perform amendments to any finalized report, of which shall supersede and make obsolete any previous editions. Such changes, modifications, additions, or deletions shall be effective immediately upon notice thereof, which may be given by means including but not limited to posting on the SanAir client portal website, electronic or conventional mail, or by any other means. The information provided in this report applies only to the samples submitted and is relevant only for the date, time, and location of sampling. The accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client on the COC. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample(s) in the condition in which they arrived at the laboratory and information provided by the client on the COC, such as: project number, project name, collection dates, po number, special instructions, samples collected by, sample numbers, sample identifications, sample type, selected analysis type, flow rate, total volume or area, and start stop times that may affect the validity of the results in this report. Samples were received in good condition unless otherwise noted on the report. SanAir assumes no responsibility or liability for the manner in which the results are used or interpreted. This report does not constitute nor shall not be used by the client to claim product, process, system, or person certification, approval, or endorsement by NVLAP, NIST, NELAC, AIHA LAP, LLC or any other U.S. governmental agencies and may not be accredited by every local, state, and federal regulatory agencies. Samples are held for a period of 60 days. Fibers smaller than 5 microns cannot be seen with this method due to scope limitations. For NY state samples, method EPA 600/M4-82-020 is performed. NYELAP Disclaimer: Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing. Asbestos Accreditations National Voluntary Laboratory Accreditation Program (NVLAP) Lab Code 200870-0 City of Philadelphia Department of Public Health Air Management Services, Certification#ALL-460 Commonwealth of Pennsylvania Department of Environmental Protection Number 68-05397 California State Environmental Laboratory Accreditation Program Certificate Number 2915 Colorado Department of Public Health and Environment Registration Number AL-23143 Connecticut Department of Public Health Environmental Laboratory Registration Number PH-0105 Massachusetts Department of Labor Standards Asbestos Analytical Services License Number: AA000222 State of Maine Department of Environmental Protection License Number: LB-0075, LA-0084 New York State Department of Health Laboratory ID: 11983 State of Rhode Island Department of Health Certification No.: PCM00126, PLM00126, TEM00126 Texas Department of State Health Services License Number: 300440 Commonwealth of Virginia Department of Professional and Occupational Regulation Number: 3333000323 State of Washington Department of Ecology Laboratory ID: C989 State of West Virginia Bureau for Public Health Analytical Laboratory Number: LT000616 Vermont Department of Health License Number: Asb-Co-An-000006 Louisiana Department of Environmental Quality AI Number 212253, Certificate #05088 Revision Date: 4/18/2023 Page 9 of 11 Page 10 of 11 Page 11 of 11 SECTION 3 |Photographs SURVEY PHOTOS 7530 204th St NE, Arlington, WA 98223 SURVEY PHOTOS 7530 204th St NE, Arlington, WA 98223 SURVEY PHOTOS 7530 204th St NE, Arlington, WA 98223 SURVEY PHOTOS 7530 204th St NE, Arlington, WA 98223 SECTION 4 |AHERA Certification