Loading...
HomeMy WebLinkAbout18329 HAWKSVIEW DR ARLINGTON, WA 98223-4638_6685_2026 CITYOFARLINGTON 1820459thAvenueNE,Arlington,WA98223 INSPECTIONS:360-403-3417-PermitCenter:360-403-3551 BUILDINGPERMIT 18329HAWKSVIEWDR Permit#:6685 PERMITEXPIRES180DAYSAFTER Parcel#:00898300001500 DATEOFISSUANCE. ScopeofWork:Remove/replacetanklesswaterheater Valuation:6088.00 OWNER APPLICANT CONTRACTOR MASSEYGRANTK FastWaterHeater FASTWATERHEATER 18329HAWKSVIEWDR 16120Woodinville-Redmondrdnesuite15 11715NCREEKPKWYS,SteC106 ARLINGTON,WA98223-4638 woodinville,wa,98072 BOTHELL,WA98011 4252960438 425.636.7054 LIC:602564544 EXP:05/31/2026 LIC:FASTWWH948BC EXP:01/04/2026 MECHANICALCONTRACTOR PLUMBINGCONTRACTOR LIC#: EXP: LIC#: EXP: JOBDESCRIPTION PERMITTYPE: RESIDENTIALMECHANICAL CODEYEAR: 2021 STORIES: 2 CONST.TYPE: VB DWELLINGUNITS: OCCGROUP: R-3;Residential BUILDINGS: OCCLOAD: PERMITAPPROVAL Theissuanceorgrantingofthispermitshallnotbeconstruedtobeapermitfor,orapprovalof,anyviolationofthisCodeorany otherordinanceororderoftheCity,ofanystateorfederallaw,orofanyorder,proclamation,guidanceadviceordecisionofthe GovernorofthisState.Totheextenttheissuanceorgrantingofthispermitisinterpretedtoallowconstructionactivityduringany periodoftimewhensuchconstructionisprohibitedorrestrictedbyanystateorfederallaw,ororder,proclamation,guidanceadvice ordecisionoftheGovernorofthisState,thispermitshallnotauthorizesuchworkandshallnotbevalid.Thebuildingofficialis authorizedtopreventoccupancyoruseofastructurewhereinviolationofthisCode,anyotherCityordinancesofthisjurisdictionor anyotherordinanceorexecutiveorderoftheCity,orofanystateorfederallaw,orofanyorder,proclamation,guidanceadviceor decisionoftheGovernor.Thebuildingofficialisauthorizedtosuspendorrevokethispermitifitisdeterminedtobeissuedinerroror onthebasisofincorrect,inaccurateorincompleteinformation,orinviolationofanyCityordinance,regulationororder,stateor federallaw,oranyorder,proclamation,guidanceordecisionoftheGovernor. IAGREETOCOMPLYWITHCITYANDSTATELAWSREGULATINGCONSTRUCTIONANDINDOINGTHEWORK AUTHORIZEDTHEREBY;NOPERSONWILLBEEMPLOYEDINVIOLATIONOFTHELABORCODEOFTHE STATEOFWASHINGTONRELATINGTOWORKMEN'SCOMPENSATIONINSURANCEANDRCW18.27. THISAPPLICATIONISNOTAPERMITUNTILSIGNEDBYTHEBUILDINGOFFICIALORHIS/HERDEPUTYAND ALLFEESAREPAID. ITISUNLAWFULTOUSEOROCCUPYABUILDINGORSTRUCTUREUNTILAFINALINSPECTIONHASBEEN MADEANDAPPROVALORACERTIFICATEOFOCCUPANCYHASBEENGRANTED.IBC110/IRC110. SALESTAXNOTICE:SalestaxrelatingtoconstructionandconstructionmaterialsintheCityofArlingtonmustbereportedon yoursalestaxreturnformandcodedCityofArlington#3101. 08/25/2025 8/26/2025 ApplicantSignature Date BuildingOfficial Date CONDITIONS Adheretoapprovedappliances.Permitshallbeonsiteforinspection.Callforfinalinspection. Thepropertyownershallensurethattheconstructionprojectcomplieswithallapplicablezoningcodesandregulations.Theproperty ownershallalsoensurethattheconstructionprojectdoesnotcauseanyadverseimpactonthesurroundingenvironmentor community.Thepropertyownershallberesponsibleforobtainingallnecessarypermitsandapprovalsfromtherelevantauthorities beforecommencingconstruction.Thepropertyownershallensurethattheconstructionprojectcomplieswithallapplicabledesign reviewrequirements. THISPERMITAUTHORIZESONLYTHEWORKNOTED.THISPERMITCOVERSWORKTOBEDONEONPRIVATE PROPERTYONLY.ANYCONSTRUCTIONONTHEPUBLICDOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILLREQUIRESEPARATEPERMISSION. PERMITFEES Date Description FeeAmount 08/25/2025 Processing/Technology $25.00 08/25/2025 Inspection $75.00 08/25/2025 MechanicalBase $25.00 08/25/2025 WaterHeater-LPG $25.00 TotalDue: $150.00 TotalPayment: $150.00 BalanceDue: $0.00 CALLFORINSPECTIONS Callby3:30pmfornextdayinspection,allow48hoursforFireInspections Whencallingforaninspectionpleaseleavethefollowinginformation: PermitNumber,TypeofInspectionbeingrequested,andwhetheryouprefermorningorafternoon INSPECTIONINFORMATION Pass/Fail RESIDENTIAL MECHANICAL APPLICATION Community and Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit:  New Installation  Addition/Alteration/Repair  Gas Piping 18329 Hawksview Drive 6088 Property Address: Project Valuation: Lot #: Parcel ID No.: Preferred Contact:  Owner  Contractor Tankless water heater replacement Project Description: Owner Name: Aime Muyumba Home No.: Email Address: aluboya@gmail.com Cell No.: 425-315-6352 18329 Hawksview Dr Arlington WA 98223 Mailing Address: City: State: Zip: Contractor Name: Fast Water Heater Office No.: 425-298-6968 Email Address: permits@fastwaterheater.com Cell No.: Mailing Address: 16120 Redmond-Woodinville RD NE #15 City: Woodinville State: WA Zip: 98072 L&I Contractor License Number: FASTWWH948BC Expiration Date: 1/4/2026 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information  Not Applicable  CSST Brass Other Proposed Piping Material: Black Steel Galvanized Steel _______________________________________ Proposed Piping Size: ½”  ⅝”  ¾”  1”  1½”  2” Distance from Meter to furthest Appliance: Total BTU’s of all Appliances: Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Type of Fixture No. of Cost per Unit Subtotal Model No. Units Additional Plan Review fees x $ 75.00 = Air Conditioning Unit ≤ 100 Btu/h x $ 15.00 = Air Conditioning Unit > 100 Btu/h x $ 25.00 = Air Conditioning Unit > 500 Btu/hp x $ 50.00 = Air Handling Units x $ 15.00 = Base Mechanical Fee 1 x $ 25.00 = $ 25.00 Boiler <100Btu/h >3hp x $ 15.00 = REV03.2022 Page 1 of 3 Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Boiler >1 million Btu/h<50hp x $ 25.00 = Boiler >1.5 million Btu/h<50hp x $ 50.00 = Boiler >100Btu/h 3-15hp x $ 15.00 = Boiler >500Btu/h 15-30hp x $ 25.00 = Commercial Hoods -Type I x $ 25.00 = Commercial Hoods -Type II x $50.00 = Diffusers x $ 15.00 = Dryer Ducting x $ 15.00 = Ductwork (drawings required) x $ 25.00 = Evaporative Coolers x $ 15.00 = Exhaust/Ventilation Fans x $ 15.00 = Fireplace/Insert/Stove x $ 15.00 = Forced Air Heat ≤100 Btu/h x $ 15.00 = Forced Air Heat >100 Btu/h x $ 25.00 = Gas Clothes Dryer x $ 15.00 = Gas Fired Air Conditioning Unit ≤ 100 Btu/h x $ 15.00 = Gas Fired Air Conditioning Unit > 100 Btu/h x $ 25.00 = Gas Fired Air Conditioning Unit > 500 Btu/hp x $ 50.00 = Gas Piping ≤ 5 units x $ 15.00 = Gas Piping for each additional unit > 5 x $ 2.00 = Heat Exchangers x $ 15.00 = Heat Pump-Condensing Unit x $ 25.00 = Hot Water Heat Coils x $ 15.00 = Miscellaneous Appliance - regulated by $ 15.00 x = mechanical code, not otherwise specified Package Units ≤ 100 Btu / > 100 Btu x $ 25.00/$50.00 = Range/Cook top-Gas Fired x $ 15.00 = Refrigeration Unit ≤100Btu/h x $ 15.00 = Refrigeration Unit >100Btu/h x $ 25.00 = Refrigeration. Unit >500Btu/h x $ 50.00 = Re-inspection fee x $ 75.00 = Residential Range Hood x $ 15.00 = Unit Heaters ≤ 100 Btu/h x $ 15.00 = Unit Heaters >100 Btu/h x $ 25.00 = Variable Air Volume Boxes (part of Air $ 10.00 x = Conditioning System) Wall Heaters - Gas Fired x $ 25.00 = Water Heater - Gas Fired 1 x $ 25.00 = 25 Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulation of the State of Washington. Jordan Johnson 8/25/2025 Signature Print Name Date REV2.2024 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY  SCHEMATIC IS TO SCALE  SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated REV2.2024 Page 3 of 3 NPE-2 Series Tankless Water Heaters Premium Condensing Tankless Gas Water Heater Specification Sheet Certified design according to the latest ANSI Z21.10.3 - CSA 4.3 standards for both indoor and outdoor installations (with optional Outdoor Vent Kit) Compatible with 1/2" gas pipe up to 24 ft* equivalent length (*see Installation Manual for additional information) Compatible with 2" PVC vent up to 75 ft** and 3" Vent up to 150 ft** (**with no elbows) Gas Type Designed for use in Residential and Commercial applications Recirclation/ Main/Sub (see Space Heating below for available models and warranty terms) Flow Rate/Status Temperature Setting Gas Input Range Combustion/erroeCombustion/Error NPE-150S2 - 120,000 to 18,000 BTU/h NPE-180A2/S2 - 150,000 to 10,000 BTU/h Menu Button Up Button NPE-210A2/S2 - 180,000 to 12,000 BTU/h Back Button Down Button NPE-240A2/S2 - 199,900 to 13,300 BTU/h OK Button Hot Water Flow Rate Capacity (*based on 35°F temperature rise) NPE-150S2 - 6.8 GPM NPE-180A2/S2 - 8.4 GPM NPE-210A2/S2 - 10.1 GPM Certified Design Compatible with Multi-Line Control NPE-240A2/S2 - 11.2 GPM 2” PVC and 1/2” Gas Pipe Panel with Diagnostics TDR (Turndown Ratio) up to 15:1 Dual Primary and Secondary Stainless Steel Heat Exchangers for optimum efficiency and durability Built-In Advanced Multi-Line Control Panel with Setup Wizard allows adjustment of temperature settings and displays of Indoor and Outdoor operating status and error codes Venting Options TMTechnology - NPE-A2 models come with 2” Intake Cap built-in 0.5 gallon Buffer Tank and Recirculation Pump to provide 2" Coupling maximum hot water comfort (NaviCirc Crossover Valve optional) 2" Pipe Outdoor INTELLIGENT Preheating - recognizes hot water usage patterns to Vent Cap intelligently provide hot water to fixtures when needed Temperature Options - available temperature settings for Residential applications range from 97°F p to 140°F with high- temperature Commercial mode capable of up to 185°F Ready-Link Cascade Compatible for up to 32 units for increased hot water production Non-Direct Vent (Indoor) Non-Direct Vent (Outdoor) Common Vent Compatible - allows for cascade systems to use a Direct Vent (Indoor) single exhaust and/or intake pipe for up to 12 units with the use of the Common Vent Backflow Damper Collar Kit (#30014367A) Compatible with Wi-Fi Control (#PBCM-AS-001) Freeze Protection - maintains normal operation in cold weather * NPE-150S2 conditions when the unit is installed INDOORS and connected to power. Excluded For OUTDOOR installations: the ambient temperature at the installation location must be above 32°F (0°C) and below 125°F (52°C) Note Refer to the Installation Manual for additional Freeze Protection guidelines Uniform Energy Factor (listed models for use with Natural Gas and Propane) NPE-150S2 - 0.93 UEF NPE-180A2/210A2/240A2 - 0.95 UEF NPE-180S2/210S2/240S2 - 0.96 UEF Job Name: _____________________________________________ Compatible for use with Natural Gas (NG) and Propane (LP) Gas*** (*** requires installation of included Gas Conversion Kit by a qualified gas servicer) Location: ______________________________________________ Approved for installations on Manufactured Homes Engineer: _____________________________________________ Certified by CSA Group, NSF 5 and 372 Low Lead, AHRI Certified, SCAQMD Wholesaler: __________________________________________ (Rule 1146.2 Type 1 - Complies with 14 ng/J or 20 ppm NOx @ 3% O2) Contractor: ___________________________________________ Limited Warranty - 15-Year Heat Exchanger and 5-Year Parts (Residential)**** Model No.: _____________________________________________ 8-Year Heat Exchanger and 5-Year Parts (Commercial)**** Submitted to: _________________________________________ (**** full details of warranty terms available in the Navien manuals or website) Optional Accessories are available (see below) Condensate Neutralizer Plumb Easy Valve Set (3/4") Ready-Link 3" Vent Termination Remote Controller (GXXX001322 - Single Unit) NPE-2 Outdoor Vent Kit External Pump Wire (30009323A - Lead Free) Communication Cable Caps and Wall Flanges (30022717B) (GXXX001324 - Up to 6 Units) (30025801A) (GXXX001319) (30025812A - for Pipe Cover) (GXXX000546) (GXXX3873B) (GXXX001325 - Up to 16 Units) 1-NPE2-SS-001-1.1 NPE-2 Series Tankless Water Heaters Premium Condensing Tankless Gas Water Heater Front View Item NPE-150S2* NPE-180A2 NPE-180S2 NPE-210A2 NPE-210S2 NPE-240A2 NPE-240S2 Heat Capacity Natural Gas, 18,000-120,000 10,000-150,000 BTU/H 12,000-180,000 BTU/H 13,300-199,900 BTU/H (Input) Propane Gas BTU/H Uniform UEF (for NG & LP) 0.93 0.95 0.96 0.95 0.96 0.95 0.96 Energy Factor mm) 35 °F (19 °C) 6.8 GPM 8.4 GPM (32 L/m) 10.1 GPM (38 L/m) 11.2 GPM (42 L/m) (695 Temp Rise (25.8 L/m) (731 mm) 28.8 in27.4 in Flow Rate 45 °F (25 °C) 5.3 GPM 6.5 GPM (25 L/m) 7.8 GPM (30 L/m) 8.7 GPM (33 L/m) (DHW) Temp Rise (20 L/m) 67 °F (36 °C) 3.4 GPM 4.3 GPM 4.4 GPM 5.1 GPM 5.3 GPM 5.6 GPM 5.8 GPM Temp Rise (13 L/m) (16 L/m) (17 L/m) (19 L/m) (20 L/m) (21 L/m) (22 L/m) Dimensions 17.3 in (W) x 27.4 in (H) x 13.2 in (D) 62 lbs 73 lbs 68 Ibs 77 Ibs 73 lbs 77 Ibs 73 lbs Weight (28 kg) (33 kg) (31 kg) (35 kg) (33 kg) (35 kg) (33 kg) Installation Type Indoor or Outdoor Wall-Hung Venting Type Forced Draft Direct Vent Overhead View A B Ignition Electronic Ignition 10 mm) Water Pressure 15-150 PSI 1.5 in (38 mm) 14.3 in (364 mm) 0.4 in ( mm) Natural Gas Supply Pressure mm) (67 3.5 in WC-10.5 in WC 77 2.6 in (from source) in ( 3 Propane Gas Supply Pressure 8 in WC-13in WC (from source) 4.5 in (115 mm) 6.7 in (170 mm) Natural Gas Manifold Pressure –0.04 in WC - –0.03 in WC - –0.55 in WC –0.03 in WC - –0.76 in WC –0.03 in WC - –0.96 in WC (min-max) –0.40 in WC Propane Gas Manifold Pressure –0.03 in WC - –0.02 in WC - –0.55 in WC –0.02 in WC - –0.76 in WC –0.02 in WC - –0.96 in WC (min-max) –0.40 in WC Minimum Flow Rate 0.5 GPM (1.9 L/m), < 0.01 GPM (0.04 L/m) option for “A2” models** Supply Connections 3/ C D E F G Cold Water Inlet 4 in NPT Description Diameter Connection Hot Water A Air Intake 2 in Sizes Outlet 3/4 in NPT B Exhaust Gas Vent 2 in (731 mm) Gas Inlet 3/ 3 in 4 in NPT C Hot Water Outlet /4 in 28.8 Main Supply 120 V AC, 60 Hz D Gas Inlet 3/4 in 336 mm) E Recirculation Inlet 3/4 in 13.2 in ( Maximum mm) mm) Power Supply (166 61 mm) 61 Power 200 W (max 2 A), 350 W (max 4 A) with external pump connected F Condensate Outlet 1/ in in ( 2 in 6.5 2.4 in ( 2.4 Consumption G Cold Water Inlet 3/ 4 in 2.3 in (60 mm)3.0 in (77 mm) 8.3 in (212 mm) Casing Cold Rolled Carbon Steel 17.3 in (440 mm) Materials Heat Primary Heat Exchanger: Stainless Steel Exchangers Secondary Heat Exchanger: Stainless Steel NPE-180A2 / 210A2 / 240A2 2 in or 3 in PVC, CPVC, Approved Polypropylene and stainless steel Exhaust 2 in or 3 in Special Gas Vent Type BH (Class II, A/B/C) Supply Connections Venting Intake 2 in or 3 in PVC, CPVC, Approved Polypropylene and stainless steel Description Diameter C D E F 2 in or 3 in Special Gas Vent Type BH (Class II, A/B/C) A Air Intake 2 in Vent Clearances 0 in to combustibles B Exhaust Gas Vent 2 in High Elevation 10,100 feet for both NG or LP gas. Please refer to Installation Manual for additional details and instructions. C Hot Water Outlet 3/ 4 in D Gas Inlet 3/ Flame Rod, APS, Ignition Operation Detector, Water Temperature High Limit Switch, Exhaust Temperature High Limit Sensor, 4 in Safety Devices E Condensate Outlet 1/2 in 13.2 in (336 mm) mm) Power Surge Fuse, Burner High Limit Fuse, Vent Installation Detector (VID) (166 mm) F Cold Water Inlet 3/ 6.5 in in (61 4 in 2.4 in (61 mm) 2.4 * NPE-150S2 model not certified by EnergyStar ** Available for “A2” models configured in an optional ComfortFlow recirculation mode. Energy consumption will increase when the system is 2.3 in (60 mm) 11.3 in (289 mm) configured for recirculation. 17.3 in (440 mm) NPE-150S2 / 180S2 / 210S2 / 240S2 Gas-fired, tankless, condensing, wall-mounted water heater(s) shall be direct vent NPE-2 Series models as manufactured by Navien, Inc. and are certified by CSA Group to the latest edition of ANSI Standard Z21.10.3-CSA 4.3. Water heater(s) shall have a 15(5)-year limited Heat Exchanger warranty and 5(3)-year limited Parts warranty (8(5)-year Heat Exchanger and 5(3)-year Parts for Commercial use) per Navien Limited Warranty. Unit(s) shall be designed to burn natural gas and can be for use with propane when a Gas Conversion Kit is installed. ________ (qty). NPE water heater(s) shall have a nominal flow rate capacity of ________ GPM/GPH at ________°F rise with rated input of _____________ BTU/hr. Water heater(s) shall be vented with 2“ Schedule 40/80 PVC/CPVC, approved polypropylene and stainless steel vent pipe at a distance not to exceed 75’ (or equivalent) with each elbow equal to 8’ of pipe length or 3” Schedule 40/80 PVC/ CPVC, approved polypropylene and stainless steel vent pipe at a distance of 150’ (or equivalent) with each elbow equal to 5’ of pipe length. Water heater(s) is rated for 150 PSI working water pressure and 300 PSI test pressure. Gas supply pressure shall be 3.5" to 10.5” WC for natural gas and 8.0“ to 13.0” WC for propane. Unit(s) shall have a steel case, dual stainless steel heat exchangers, eco premixed burner, negative pressure gas valve, dual venturi, 3/4” inlet gas connection, 3/4” brass inlet/outlet water connections, water holding capacity of 0.6 gallons for the NPE-150S2, 1.0 gallon for the NPE-180A2 model (0.7 gallons for NPE-180S2 model), 1.2 gallons for the NPE-210A2/NPE-240A2 models (0.7 and 0.9 gallons for NPE-210S2 and NPE-240S2 models respectively), and a condensate collector. The NPE-180A2 model weighs 73 lbs (NPE-180S2 weighs 68 lbs), and the NPE-210A2/NPE-240A2 models weigh 77 lbs (NPE-210S2 and NPE-240S2 weigh 73 lbs) and the NPE-150S2 weigh 62lbs. Unit(s) shall include features such as an adjustment for installations at high elevation, temperature lockout, and temperature options from 97-120°F in 1°F intervals and 120-140°F in 1°F intervals. The unit(s) shall include additional temperature options of 140-185°F in 1°F intervals, for high temperature commercial applications. All NPE “A2” models shall include an internal circulation pump and 0.5-gallon buffer tank. The water heater(s) shall be controlled by an internal circuit board that monitors the inlet and outlet temperatures with installed thermistors, sensing and controlling flow rate to set point temperature with air-fuel ratio controls in order to maintain thermal combustion efficiency. Unit(s) shall include safety features such as flame sensor system, high limit sensors, overheat prevention device, freeze protection mode, and fan motor rotation detector. Multi- system (cascade) applications that require 2 to 32 units shall be installed by connecting the units using cable only connections (Ready Link). The water heater(s) exceeds the energy efficiency requirements of ASHRAE 90.1-2010 and is listed by SCAQMD Rule 1146.2 (Type 1) as compliant with Rule 1146.2 (Type 1) for Ultra Low NOx requirements of 14 ng/J or 20 ppm @ 3% O2. * Navien reserves the right to change specifications at any time without prior notice Navien, Inc. 20 Goodyear, Irvine, CA 92618 Ph: (949)420-0420 Fax: (949)420-0430 www.NavienInc.com 1-NPE2-SS-001-1.1 Permit #: 6685 Permit Date: 08/25/25 Permit Type: RESIDENTIAL MECHANICAL Project Name: Muyumba Applicant Name: Fast Water Heater Applicant Address: 16120 Woodinville-Redmond rd ne suite 15 Applicant, City, State, Zip: woodinville, wa, 98072 Contact: Jordan Johnson Phone: 4252960438 Email: permits@fastwaterheater.com Scope of Work: Remove/replace tankless water heater Valuation: 6088.00 Square Feet: 2383 Number of Stories: 2 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 08/26/2025 Permit Expires: 02/25/2026 Form Permit Type: RESIDENTIAL MECHANICAL Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 100 SINGLE 00898300001500 18329 HAWKSVIEW DR MASSEY GRANT K FAMILY RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License # 11715 N CREEK FAST WATER PLUMBING 425.636.7054 PKWY S, Ste COA 602 564 544 HEATER CONTRACTOR C106 11715 N CREEK FAST WATER PLUMBING LABOR & 425.636.7054 PKWY S, Ste FASTWWH948BC HEATER CONTRACTOR INDUSTRIES C106 Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C00. 10/10/2025 10/13/2025 10/13/2025 BUILDING Approved CONSULTATION Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Mechanical Base Permit Fee $25.00 Water Heater - LPG Gas Fired $25.00 Credit Card Service $4.50 Total $154.50 Attached Letters Date Letter Description 08/25/2025 Building Permit 08/25/2025 Web Form- Residential Mechanical Application Payments Date Paid By Description Payment Type Accepted By Amount 08/25/2025 Anthony Danese 241194284 Hannah Hardwick $4.50 XBP Conf: 08/25/2025 $150.00 241194284 Outstanding Balance $0.00 Uploaded Files Date File Name 08/26/2025 27994372-2025_BLD6685_IssuedPermit.pdf 08/25/2025 b27382e7226712ecccfb3cbadebb1e06_3105408_app.pdf 08/25/2025 7a30f6129445146b43ec3f0f2194d0e0_3105408_specs.pdf