Loading...
HomeMy WebLinkAbout8508 E Gilman Ave_BLD4610_2025 Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551 Page 1 of 1 Permit Number: Permit Type: Address/Parcel: Completed (Month/Year): Land Use ˆ Notice of Decision ˆ Staff Report ˆ Application ˆ Narrative ˆ Legal Description ˆ Vicinity Map ˆ Site Plan ˆ Landscape Plan ˆ Complete Streets Checklist ˆ Traffic Impact Analysis ˆ Snohomish County Traffic Mitigation Offer ˆ WSDOT Traffic Offer Form ˆ Tree Survey ˆ Stormwater Drainage Report ˆ Geotech Report ˆ Critical Area Evaluation Form ˆ SEPA Checklist ˆ Public Notice Material ˆ Noticing and Related Documents ˆ Water / Sewer Availability Certificate ˆ Unanticipated Discovery Plan Form ˆ Aerial Photo of Site ˆ Proposed Building Materials ˆ Lighting Plans and Lighting Cut Sheets ˆ Color Elevations ˆ Design Matrix ˆ Plat Map ˆ Title Report ˆ Lot Closures ˆ Preliminary Civil Plans ˆ Archaeological Survey o Confidential Documents. Contact the City to obtain. ˆ Topography (Existing Conditions) ˆ CC&R’s ˆ Deeds / Easements / Conveyances /Dedications ˆ Developer’s Agreement ˆ Recorded Copies ˆ Bonding or Assignment of Funds o Confidential Documents. Contact the City to obtain. ˆ Letters and Project Documents ˆ Other: Civil ˆ Issued Permit ˆ Application ˆ Other Applications ˆ Construction Calculation Worksheet ˆ Approved Plans ˆ Review Comment Form ˆ Letters and Project Documents ˆ Other Agency Permits ˆ Reports: o Drainage Report Pg: o Stormwater Pg: o Geotech Pg: o All Other Reports ˆ SEPA and Noticing Materials ˆ Inspections ˆ As-Builts ˆ Other: Building ˆ Issued Permit ˆ Application ˆ Additional Applications ˆ Approved Plans ˆ Site Plan ˆ Letters and Project Documents ˆ Calculations ˆ Project Specification Manuals ˆ Reports ˆ Certificate of Occupancy ˆ Inspections ˆ Other: BLD4610 Fire Sprinkler 8508 E Gilman Ave December 2024 ✔ ✔ ✔ ✔ ✔ ✔ Model RFC Cover Plate Model RFC43 & RFC43LLModel RFC30 & RFC30LL Model RFC49 & RFC49LL Model RFC58 Features • cULus Listed as Residential Sprinklers • Push-On cover plate installation • Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL) and Australian WaterMark Certified (WMCS). Model RFC30 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC43, RFC49, RFC58, and RFC76 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link oper- ating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and are listed for use with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classification and are listed for use with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by ei- ther pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2” (13 mm) of cover plate adjust- ment. Model RFC58 and RFC76 sprinklers allow 3/4” (19 mm) of cover plate adjustment. Model RFC cover plates are avail- able in a variety of finishes as listed in Table H. www.reliablesprinkler.com Sprinkler Model Nominal K-Factor gpm/psi1/2 (l/min/bar1/2) Max. Coverage Area ft x ft (m x m) Listings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0 (43)14 x 14 (4.3 x 4.3)cULus RA0611 RFC30LL 3.0 (43)14 x 14 (4.3 x 4.3)cULus, LL, WMCS RA3211 RFC43 4.3 (62)20 x 20 (6.1 x 6.1)cULus RA0612 RFC43LL 4.3 (62)20 x 20 (6.1 x 6.1)cULus, LL, WMCS RA3212 RFC49 4.9 (71)20 x 20 (6.1 x 6.1)cULus RA0616 RFC49LL 4.9 (71)20 x 20 (6.1 x 6.1)cULus, LL, WMCS RA3216 RFC58 5.8 (84)20 x 20 (6.1 x 6.1)cULus RA0613 RFC76 7.6 (109)20 x 20 (6.1 x 6.1)cULus RA0618 Table A cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service. LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). WMCS: Australian WaterMark Certified. Model RFC76 cULus Listed Model RFC Series Residential Sprinklers Flat Concealed Pendent Bulletin 006 May 2019 Bulletin 006 May 2019 Page 2 of 8 www.reliablesprinkler.com Model RFC30 & RFC30LL Sprinkler Components and Dimensions Figure 1 Model RFC30 and RFC30LL Sprinkler Hydraulic Design Criteria Table B Minimum Flow and Residual Pressure (1) Max. Coverage Area (2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 12 x 12 (3.6 x 3.6) 9 (34) 9.0 (0.62) 14 x 14 (4.3 x 4.3) 10 (38) 11.0 (0.76) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table B above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Technical Specifications Style: Flat Concealed Pendent Threads: 1/2” NPT or ISO 7-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC30LL only) Watermark Certified (RFC30LL only) Bottom View Model RFC30 & RFC30LL Residential Sprinklers RFC30: SINRA0611 RFC30LL: SINRA3211 Bulletin 006 May 2019 Page 3 of 8 www.reliablesprinkler.com Model RFC43 & RFC43LL Sprinkler Hydraulic Design Criteria Table C Minimum Flow and Residual Pressure (1) Max. Coverage Area (2) ft. x ft. (m x m) Ordinary Temperature Intermediate Temperature Flow gpm (l/min) Pressure psi (bar) Flow gpm (l/min) Pressure psi (bar) 15 x 15 (4.6 x 4.6) 12 (45) 7.8 (0.54) 12 (45) 7.8 (0.54) 16 x 16 (4.9 x 4.9) 13 (49) 9.1 (0.63) 13 (49) 9.1 (0.63) 18 x 18 (5.5 x 5.5) 18 (68) 17.5 (1.21)---- 20 x 20 (6.1 x 6.1) 21 (79) 23.8 (1.64)---- Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table C above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Model RFC43 & RFC43LL Sprinkler Components and Dimensions Figure 2 Technical Specifications Style: Flat Concealed Pendent Threads: 1/2” NPT or ISO 7-1R1/2 Nominal K-Factor: 4.3 (62 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC43LL only) Watermark Certified (RFC43LL only) Bottom View Model RFC43 & RFC43LL Residential Sprinklers RFC43: SINRA0612 RFC43LL: SINRA3212 Technical Specifications Style: Flat Concealed Pendent Threads: 1/2” NPT or ISO 7-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Watermark Certified (RFC49LL only) Model RFC49 & RFC49LL Sprinkler Components and Dimensions Figure 3 Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria Table D Minimum Flow and Residual Pressure (1) Max. Coverage Area (2) ft. x ft. (m x m) Ordinary Temperature Intermediate Temperature Flow gpm (l/min) Pressure psi (bar) Flow gpm (l/min) Pressure psi (bar) 16 x 16 (4.9 x 4.9) 13 (49.0) 7.0 (0.48) 13 (49.0) 7.0 (0.48) 18 x 18 (5.5 x 5.5) 17 (64.3) 12.0 (0.83) 17 (64.3) 12.0 (0.83) 20 x 20 (6.1 x 6.1) 20 (75.7) 16.7 (1.15) 21 (79.5) 18.4 (1.27) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 May 2019 Page 4 of 8 www.reliablesprinkler.com Bottom View Model RFC49 & RFC49LL Residential Sprinklers RFC49: SINRA0616 RFC49LL: SINRA3216 Model RFC58 Residential Sprinkler SIN RA0613 Technical Specifications Style: Flat Concealed Pendent Threads: 1/2” NPT or ISO 7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Chrome Plated Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed Model RFC58 Sprinkler Components and Dimensions Figure 4 Model RFC58 Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressure( 1) Max. Coverage Area (2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 16 x 16 (4.9 x 4.9) 16 (60.6) 7.6 (0.53) 18 x 18 (5.5 x 5.5) 18 (68.1) 9.6 (0.66) 20 x 20 (6.1 x 6.1) 20 (75.7) 11.9 (0.82) Bulletin 006 May 2019 Page 5 of 8 www.reliablesprinkler.com Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bottom View Bulletin 006 May 2019 Page 6 of 8 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 3/4” NPT or ISO 7-1R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressure( 1) Max. Coverage Area (2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 16 x 16 (4.9 x 4.9) 21 (79.5) 7.6 (0.52) 18 x 18 (5.5 x 5.5) 24 (90.8) 9.9 (0.68) 20 x 20 (6.1 x 6.1) 34 (128.7) 20 (1.4) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bottom View Model RFC76 Residential Sprinkler SIN RA0618 Model RFC76 Sprinkler Components and Dimensions Figure 5 Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3)Custom Color Paint(2) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Custom color paint is semi-gloss, unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side. Cover plates are not listed or approved as corrosion resistant. Stainless steel clad cover plates are not available perforated. Cover Plate Finishes(1) Table H Bulletin 006 May 2019 Page 7 of 8 www.reliablesprinkler.com Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2” x 1/2” brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. 2. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (38°C). 3. For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (66°C). Sprinkler Model Cover Plate Model Cover Plate Diameter inch (mm) Recommended Hole Diameter in Ceiling inch (mm) Cover Plate Adjustment inch (mm) Min. to Max. Face of Fitting to Ceiling(1) inch (mm) Min. to Max. Dropped Deflector Distance below Ceiling inch (mm) Cover Plate Temperature Rating RFC30, RFC30LL RFC 3-5/16 (84) 2-5/8 (67) 1/2 (13) 1-1/2 to 2 (38 to 51) 1/2 to 1 (13 to 25) 135°F (57°C) RFC43, RFC43LL, RFC49, RFC49LL RFC 3-5/16 (84) 2-5/8 (67) 1/2 (13) 1-1/2 to 2 (38 to 51) 1/2 to 1 (13 to 25) 135°F(2) (57°C) or 165°F(3) (74°C) RFC58, RFC76 RFC 3-5/16 (84) 2-5/8 (67) 3/4 (19) 1-1/2 to 2-1/4 (38 to 57) 1/4 to 1 (6 to 25) 135°F(2) (57°C) or 165°F(3) (74°C) Table JInstallation Dimensions Installation Model RFC series sprinklers are intended to be installed in ac- cordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Mod- el RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a wrench-able protec- tive cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model RFC series sprinklers can be installed without removing the wrench-able protective cap using the Model W3 wrench. Alternatively, Model RFC series sprinklers can be installed us- ing the Model FC wrench by temporarily removing the protec- tive cap during installation of the sprinkler. The use of any other wrench to installed Model RFC series sprinklers is not permit- ted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over the sprinkler until the wrench engag- es the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2” square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler’s threads. Recommended installation torque is 8 to 18 ft-lbs (11 to 24 N-m) for 1/2” thread sprinklers and 14 to 20 ft-lbs (19 to 27 N-m) for 3/4” thread sprinklers. Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or im- pairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pen- dent residential sprinklers. Model RFC 30 and RFC30LL sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C). Model RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprin- klers are available in either ordinary or intermediate tempera- ture classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (66°C), respectively. Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler • Model (RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) • Temperature Rating Cover Plate • Model RFC • Temperature Rating • Finish (See Table H) Sprinkler Wrench • Model FC • Model W3 Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Bulletin 006 May 2019 Page 8 of 8 www.reliablesprinkler.com Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada to UL1626, Residential Sprinklers for Fire-protection Service (cULus). Certified by Underwriters Laboratories, Inc. and Underwrit- ers Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL only). Australian WaterMark Certified (RFC30LL, RFC43LL, and RFC49LL only). P/ N 9 9 9 9 9 7 0 2 6 1 Model FC For use with Model RFC Series sprinklers without wrench-able cap installed Wrench Model W3 For use with Model RFC Series sprinklers with wrench-able cap installed Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Bu l l e t i n 0 3 3 F e b r u a r y 2 0 1 9 Bulletin 033 February 2019 Model F1 RES LL Residential Sprinklers Types: 1. F1 Res 30 LL Pendent 2. F1 Res 30 LL Recessed Pendent/F2 3. F1 Res 30 LL Recessed Pendent/FP 4. F1 Res 49 LL Pendent 5. F1 Res 49 LL Recessed Pendent/F1 6. F1 Res 49 LL Recessed Pendent/FP 7. F1 Res 58 LL Pendent 8. F1 Res 58 LL Recessed Pendent/F1 9. F1 Res 58 LL Recessed Pendent/FP 10. F1 Res 30 LL CCP Pendent 11. F1 Res 49 LL CCP Pendent 12. F1 Res 58 LL CCP Pendent 13. F1 Res 44 LL HSW 14. F1 Res 44 LL Recessed HSW/F2 15. F1 Res 58 LL HSW 16. F1 Res 58 LL HSW Recessed HSW/F2 17. F1 Res 44 LL SWC Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) for Safety to ANSI/ UL1626. 2. Certified by Underwriters Laboratories, Inc. and Under- writers Laboratories of Canada for Health Effects to NSF/ ANSI Standard 61 Annex G (Less than 0.25% Lead Con- tent.) 3. WaterMark certified. WaterMark Certificate Number 23347 Additional Bulletins applicable to all F1RES LL Sprinklers • Wall Wetting - Bulletin 007 • Design and Installation - Bulletin 140 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 LL & 58 LL Pendent Sprinklers Other patents pending. F1 Res 30 LL, 49 LL, & 58 LL Recessed Pendent/FP F1 Res 49 LL & 58 LL Recessed Pendent / F1, F1 Res 30 LL Recessed Pendent/F2 F1 Res 44 LL & 58 LL Recessed HSW/F2 F1 Res 30 LL, 49 LL & 58 LL CCP Pendent F1 Res 44 LL SWC Product Description Model F1 Res LL Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitivity glass-bulb and low profile decorative design. The F1 Res LL Horizontal Sidewall sprinklers (Figs. 5, & 6) are equally attractive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in resi- dential fire protection design. The low flow F1 Res LL sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection application needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler’s heat-sensitive glass-bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: • Thermal Sensor: Nominal 3mm glass-bulb • Sprinkler Frame : Brass • Sprinklers’ Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi • Thread Size: ½” NPT (R½) • K-Factor: 3.0 (Actual) - F1 Res 30 LL Pendent Sprinkler 4.9 (Actual) - F1 Res 49 LL Pendent Sprinkler 5.8 (Actual) - F1 Res 58 LL Pendent & HSW Sprinkler 4.4 (Actual) - F1 Res 44 LL HSW Sprinkler Specifically Listed for use in Multipurpose Systems that serve both domestic water and fire protection. F1 Res 30 LL, 49 LL & 58 LL Pendent F1 Res 44 LL & 58 LL HSW 2. Application Model F1 Res LL sprinklers are cULus Listed in accor- dance with UL 1626 for installation in accordance with NFPA 13, NFPA 13R, and NFPA 13D. Sprinkler systems using Model F1 Res LL sprinklers must be hydraulically designed to provide at least the flow identified in the Tech- nical Data tables in this bulletin. For NFPA 13 installations, the flow per sprinkler must be the greater of: (1) the flow listed in the applicable Technical Data table and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For cover- age area dimensions less than those listed in the Technical Data tables, use the minimum required flow for the next larger max. coverage area listed. Installation Models F1 Res LL sprinklers are to be installed as shown. Model F1, F2 and FP Escutcheons, illustrated herewith, are the only recessed escutcheons to be used with Model F1 Res LL sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1 Res LL Pendent sprinklers use only the Model W2 sprin- kler Wrench; for installing Models F1 Res LL Recessed Pendent, CCP & SWC sprinklers use only the Model GFR2 sprinkler wrench; for installing Model F1 LL Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install F1 Res 44 LL with a ceiling to de- flector distance of 4” - 12”. Flow arrow on deflector must point away from near wall and “Top” marking must face ceiling. Escutcheon*, F1 or F2, Data: Type Adjustment Inch (mm) “A” Inch (mm) Face of fitting to ceiling Inch (mm) F1 3/4 (19.0)Min.=3/4” (19.1) Max.=11/2” (38.1) 3/16 - 15/16 (4.7 - 24.0) F2 1/2 (12.7)Min.=15/16” (23.8) Max.=11/2” (38.1) 3/16 - 11/16 (4.7 - 17.4) * Note: Escutcheons F1 or F2 may be used with Model F1 Res 49 LL & 58 LL Recessed Pendent Sprinkler • Model F1 Res 30 LL, 49 LL & 58 LL Pendent • Model F1 Res 30 LL Recessed Pendent / F2 • Model F1 Res 49 LL & 58 LL Recessed Pendent / F1 Fig. 1 Fig. 2 F1 escutcheon, 3/4” (19mm) adjustment 3. Technical Data: F1Res 30 LL Pendent and Recessed Pendent (SIN RA3311) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp.Actual K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)21/64” (8.2)175 (12)155 175 68 79 100 38 3.0 (43.2)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)8 (30.3)7.0 (0.48)8 (30.3)7.0 (0.48)Smooth Ceilings 1” to 4” (25mm to 100mm) Beamed Ceilings per NFPA 13, 13D, or 13R 8 (2.4)14 x 14 (4.3 x 4.3)14 (4.3)10 (37.8)11 (0.76)10 (37.8)11 (0.76) 16 x 16 (4.9 x 4.9)16 (4.9)13 (49)18.8 (1.3)13 (49)18.8 (1.3) Technical Data: F1Res 49 LL Pendent and Recessed Pendent (SIN RA3316) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. Actual K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)7/16” (11)175 (12)155 175 68 79 100 150 38 66 4.9 (70.6)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)13 (49)7.0 (0.48)13 (49)7.0 (0.48) Smooth Ceilings 1” to 4” (25mm to 100mm) Beamed Ceilings per NFPA 13, 13D, or 13R 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)13 (49)7.0 (0.48)13 (49)7.0 (0.48) 16 x 16 (4.9 x 4.9)16 (4.9)13 (49)7.0 (0.48)13 (49)7.0 (0.48) 18 x 18 (5.5 x 5.5)18 (5.5)17 (64.3)12 (0.83)17 (64.3)12 (0.83) 20 x 20 (6.1 x 6.1)20 (6.1)20 (75.7)16.7 (1.14)20 (75.7)16.7 (114) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)15 (57)9.4 (0.65)15 (57)9.4 (0.65) Smooth Ceilings 4” to 8” (100mm to 200mm)8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)16 (60.5)10.6 (0.73)16 (60,5)10.6 (0.73) 16 x 16 (4.9 x 4.9)16 (4.9)17 (64.3)12.0 (0.83)17 (64.3)12.0 (0.83) 18 x 18 (5.5 x 5.5)18 (5.5)19 (72)15.0 (1.0)19 (72)15.0 (1.0) 20 x 20 (6.1 x 6.1)20 (6.1)22 (83.2)20.2 (1.4)22 (83.2)20.2 (1.4) FP push-on/thread-off escutcheon 4. • Model F1 Res 30 LL, 49 LL & 58 LL CCP Pendent • Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent / FP Fig. 3 Fig. 4 Technical Data: F1Res 58 LL Pendent and Recessed Pendent (SIN RA3313) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp.Actual K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)½” (13)175 (12)155 175 68 79 100 150 38 66 5.8 (83.5)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)16 (61)7.6 (0.53)16 (61)7.6 (0.53) Smooth Ceilings 1” to 4” (25mm to 100mm) Beamed Ceilings per NFPA 13, 13D, or 13R 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)16 (61)7.6 (0.53)16 (61)7.6 (0.53) 16 x 16 (4.9 x 4.9)16 (4.9)16 (61)7.6 (0.53)16 (61)7.6 (0.53) 18 x 18 (5.5 x 5.5)18 (5.5)19 (72)10.8 (0.75)19 (72)10.8 (0,75) 20 x 20 (6.1 x 6.1)20 (6.1)22 (83,3)14.4 (1.0)22 (83.3)14.4 (1.0) 5. Technical Data: F1Res 30 LL CCP Pendent and Recessed Pendent/FP (SIN RA3311) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) CCP Assembly Temp. Rating Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)21/64” (8.2)175 (12)135 57 100 38 3.0 (43.2)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spac- ing Ft (m) Ordinary Temp. Rating (155°F/68°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)8 (30.3)7.0 (0.48)Smooth Ceilings 1/2” to 1” (13mm to 25mm) using CCP or FP escutcheon Beamed Ceilings per NFPA 13, 13D, or 13R 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)11 (37.8)13.4 (0.92) Technical Data: F1Res 49 LL CCP Pendent and Recessed Pendent/FP (SIN RA3316) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) CCP Assembly Temp. Rating Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)7/16” (11)175 (12)135 57 100 38 4.9 (70.6)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)13 (49)7.0 (0.48) Smooth Ceilings 1/2” to 1” (13mm to 25mm) using CCP or FP escutcheon Beamed Ceilings per NFPA 13, 13D, or 13R 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)13 (49)7.0 (0.48) 16 x 16 (4.9 x 4.9)16 (4.9)14 (53)8.2 (0.56) 18 x 18 (5.5 x 5.5)18 (5.5)18 (68.1)13.5 (0.93) 20 x 20 (6.1 x 6.1)20 (6.1)20 (75.7)16.7 (1.14) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. Technical Data: F1Res 58 LL CCP Pendent and Recessed Pendent/FP (SIN RA3313) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) CCP Assembly Temp. Rating Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)1/2” (13)175 (12)135 57 100 38 5.8 (83.5)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)16 (61)7.6 (0.53) Smooth Ceilings 1/2” to 1” (13mm to 25mm) using CCP or FP escutcheon Beamed Ceilings per NFPA 13, 13D, or 13R 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)16 (61)7.6 (0.53) 16 x 16 (4.9 x 4.9)16 (4.9)16 (61)7.6 (0.53) 18 x 18 (5.5 x 5.5)18 (5.5)19 (72)10.8 (0.75) 20 x 20 (6.1 x 6.1)20 (6.1)22 (83.3)14.4 (1.0) 6. • Model F1 Res 44 LL & 58 LL HSW • Model F1 Res 44 LL & 58 LL Recessed HSW/F2 F2 escutcheon, 1/2” (13mm) adjustment Technical Data: F1Res 44 LL HSW & HSW/F2 (SIN RA3331) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)3/8” (10)175 (12)155 175 68 79 100 150 38 66 4.4 (63)2.45 (62) Escutcheon, F2, Data: Type Adjustment Inch (mm) Face of Fitting to wall Inch (mm) F2 1/2 (13)3/16 - 11/16 (4.7 - 17.4) Max. Coverage area Ft x Ft (m x m) Max. Spac- ing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)12 (45.4)7.5 (0.52)12 (45.4)7.5 (0.52) 4 to 6 (100 to 152) 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)14 (53.0)10.2 (0.71)14 (53.0)10.2 (0.71) 16 x 16 (4.9 x 4,9)16 (4.9)16 (60.6)13.3 (0.92)16 (60.6)13.3 (0.92) 16 x 18 (4.9 x 5.5)16 (4.9)18 (68.1)16.8 (0.53)18 (68.1)16.8 (0.53) 18 x 18 (5.5 x 5.5)18 (5.5)19 (72.0)18.7 (1.29)19 (72.0)18.7 (1.29) 16 x 20 (4.9 x 6.1)16 (4.9)23 (87.1)27.4 (1.89)23 (87.1)27.4 (1.89) 12 x 12 (3.6 x 3.6)12 (3.6)14 (53.0)10.2 (0.71)14 (53.0)10.2 (0.71) 6 to 12 (152 to 305) 14 x 14 (4.3 x 4.3)14 (4.3)16 (60.6)13.3 (0.92)16 (60.6)13.3 (0.92) 16 x 16 (4.9 x 4.9)16 (4.9)17 (64.4)15.0 (1.04)17 (64.4)15.0 (1.04) 16 x 18 (4.9 x 5.5)16 (4.9)20 (75.7)20.7 (1.43)20 (75.7)20.7 (1.43) 16 x 20 (4.9 x 6.1)16 (4.9)23 (87.1)27.4 (1.89)23 (87.1)27.4 (1.89) Fig. 5 7. Technical Data: F1Res 44 LL SWC (SIN RA3331) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Cover Temp. Rating Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)3/8” (10)175 (12)135 57 100 38 4.4 (63)2.45 (62) • Model F1 Res 44 LL SWC Fig. 6 Technical Data: F1Res 58 LL HSW & HSW/F2 (SIN RA3333) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)1/2” (13)175 (12)155 175 68 79 100 150 38 66 5.8 (83.5)2.45 (62) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)16 (60.6)7.6 (0.53)16 (60.6)7.6 (0.53) 4 to 6 (100 to 152) 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)18 (68.2)9.7 (0.69)18 (68.2)9.7 (0.69) 16 x 16 (4.9 x 4.9)16 (4.9)21 (79.5)13.2 (0.91)21 (79.5)13.2 (0.91) 16 x 18 (4.9 x 5.5)16 (4.9)25 (94.7)18.6 (1.28)25 (94.7)18.6 (1.28) 16 x 20 (4.9 x 6.1)16 (4.9)29 (109.8)25.0 (1.73)29 (109.8)25.0 (1.73) 12 x 12 (3.6 x 3.6)12 (3.6)22 (83.3)14.4 (1.0)22 (83.3)14.4 (1.0) 6 to 12 (152 to 305) 14 x 14 (4.3 x 4.3)14 (4.3)22 (83.3)14.4 (1.0)22 (83.3)14.4 (1.0) 16 x 16 (4.9 x 4.9)16 (4.9)26 (98.4)20.1 (1.39)26 (98.4)20.1 (1.39) 16 x 18 (4.9 x 5.5)16 (4.9)31 (117.4)28.6 (1.97)31 (117.4)28.6 (1.97) Maintenance Model F1 Res 30 LL, 49 LL, F1 Res 58 LL and F1 Res 44 LL Sprinklers should be inspected and the sprinkler sys- tem maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model F1 Res 30 LL, 49 LL & 58 LL Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [WaterMark Certified WMCS] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Resi- dential sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the applicable installation standard. Deflector-to-ceiling distance listing shall be 1” to 4” maximum, unless specifically listed other- wise. Sprinkler frame and deflector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a PTFE-coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard fin- ish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 30 LL, 49 LL & 58 LL, SIN RA3311, RA3316 & RA3313 (Bulletin 033). Model F1 Res 49 LL & 58 LL Recessed Pendent/F1 Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/F2 Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/FP Specifications Sprinklers shall be [cULus Listed] [WaterMark Certified WMCS] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in con- formance with the manufacturer’s installation guidelines and the applicable installation standard. Deflector-to-ceil- ing distance listing shall be 1” to 4” maximum, unless spe- cifically listed otherwise. Sprinkler frame and deflector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a PTFE-coated Bel- leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½” adjustment (Model F2)] [with ¾” adjustment (Model F1)] [of push-on and thread off design with ½” adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/F1] [Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/F2] [Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/FP] SIN RA3311, RA3316 & RA3313 (Bulletin 033). 8. Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)13 (49.2)8.7 (0.60) 4 to 6 (100 to 152) 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)14 (53.0)10.2 (0.71) 16 x 16 (4.9 x 4.9)16 (4.9)17 (64.3)15.0 (1.1) 16 x 18 (4.9 x 5.5)16 (4.9)19 (71.8)18.7 (1.13) 16 x 20 (4.9 x 6.1)16 (4.9)23 (87.1)27.4 (1.89) 12 x 12 (3.6 x 3.6)12 (3.6)14 (52.9)10.2 (0.71) 6 to 12 (152 to 305) 14 x 14 (4.3 x 4.3)14 (4.3)15 (56.7)11.7 (0.81) 16 x 16 (4.9 x 4.9)16 (4.9)18 (68.1)16.8 (1.16) 16 x 18 (4.9 x 5.5)16 (4.9)20 (75.6)20.7 (1.43) Technical Data: F1Res 44 LL SWC (SIN RA3331) continued Model F1 Res 30 LL, 49 LL & 58 LL CCP Pendent (Concealed) Specifications Sprinklers shall be [cULus Listed] [WaterMark Certified WMCS] low flow residential concealed sprinklers engi- neered to provide a minimum design density of 0.05 gpm/ ft2 over the listed coverage area. Listed flows as speci- fied by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in confor- mance with the manufacturer’s installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a PTFE- coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plas- tic parts, and having a temperature rating of 155°F (68°C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½” cover plate adjustment. Cover plate temperature rating shall be 135°F (57°C). A plastic protective cap shall be provided and factory in- stalled inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color– specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 30 LL, 49 LL & 58 LL CCP, SIN RA3311, RA3316 & RA3313 (Bulletin 033). Model F1 Res 44 LL Horizontal Sidewall Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] [WaterMark Certified WMCS] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in confor- mance with the manufacturer’s installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a PTFE- coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plas- tic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.4 (62.8). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Residential hori- zontal sidewall sprinklers shall be Reliable Model F1 Res 44 LL, SIN RA3331 (Bulletin 033). Model F1 Res 44 LL Recessed Horizontal Sidewall Sprinkler Specifications Use description for the Model F1 Res 44 horizontal side- wall sprinkler with the following modifications: Replace “horizontal sidewall sprinkler” with “recessed horizontal sprinkler.” Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½” adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish– specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 44 LL/F2, SIN RA3331 (Bulletin 033). Standard Finishes Sprinkler F1, F2, FP Escutcheons Cover Plates Bronze Chrome Plated White and Black Polyester Coated Brass Bright Chrome Plated White Painted White Painted Chrome Special Application Finishes Sprinkler F1, F2, Escutcheons Cover Plates Bright Brass Black Plated Black Paint Off White Satin Chrome Bright Brass Black Plated Black Paint Off White Satin Chrome Bright Brass Black Plated Black Paint Off White Satin Chrome (1) Other finishes and colors are available on special order. Consult factory for details. Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4. Sprinkler Finish 5. Escutcheon Finish 6. Cover Plate Finish Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 02/19 P/N 9999970411 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. 1ProPEX® is a registered trademark of Uponor, Inc. ProPEX™ is a trademark of Uponor Ltd. 2Visit listing agency’s website for complete information. 3For ¾", 1" and 1¼" pipe only. 4For ¾" to 3" pipe. Uponor AquaPEX® White, coils Submittal information Project information Technical data 180°F (82°C) at 100 psi (689 kPa) 73.4°F (23°C) at 160 psi (1,103 kPa) ½", ¾", 1", 1¼", 1½" and 2" Uponor AquaPEX® White only: 120°F (49°C) at 130 psi (896 kPa) Product information and application use as radiant heating/cooling and hydronic piping systems containing no ferrous corrodible components or where ferrous components are isolated from the piping.  Description Part number I.D. O.D. Weight ⅜" Uponor AquaPEX White, 400-ft. coil ⅜" Uponor AquaPEX White, 1,000-ft. coil ½" Uponor AquaPEX White, 100-ft. coil ½" Uponor AquaPEX White, 300-ft. coil ½" Uponor AquaPEX White, 500-ft. coil ½" Uponor AquaPEX White, 1,000-ft. coil ⅝" Uponor AquaPEX White, 300-ft. coil ⅝" Uponor AquaPEX White, 1000-ft. coil ¾" Uponor AquaPEX White, 100-ft. coil ¾" Uponor AquaPEX White, 300-ft. coil ¾" Uponor AquaPEX White, 500-ft. coil 1" Uponor AquaPEX White, 100-ft. coil 1" Uponor AquaPEX White, 300-ft. coil 1" Uponor AquaPEX White, 500-ft. coil 1¼" Uponor AquaPEX White, 100-ft. coil 1¼" Uponor AquaPEX White, 300-ft. coil 1½" Uponor AquaPEX White, 100-ft. coil 1½" Uponor AquaPEX White, 300-ft. coil 2" Uponor AquaPEX White, 100-ft. coil 2" Uponor AquaPEX White, 200-ft. coil 2" Uponor AquaPEX White, 300-ft. coil 2½" Uponor AquaPEX White, 100-ft. coil 2½" Uponor AquaPEX White, 300-ft. coil 3" Uponor AquaPEX White, 100-ft. coil F1090375 F1120375 F1040500 F1060500 F1100500 F1120500 F1060625 F1120625 F1040750 F1060750 F1100750 F1041000 F1061000 F1101000 F1061250 F1021250 F1061500 F1021500 F1062000 F1052000 F1022000 F1062500 F1022500 F1063000 0.350" 0.350" 0.475" 0.475" 0.475" 0.475" 0.574" 0.574" 0.671" 0.671" 0.671" 0.862" 0.862" 0.862" 1.054" 1.054" 1.244" 1.244" 1.629" 1.629" 1.629" 2.011" 2.011" 2.400" 0.500" 0.500" 0.625" 0.625" 0.625" 0.625" 0.750" 0.750" 0.875" 0.875" 0.875" 1.125" 1.125" 1.125" 1.375" 1.375" 1.625" 1.625" 2.125" 2.125" 2.125" 2.625" 2.625" 3.125" 20.0 lbs. 44.0 lbs. 6.0 lbs. 18.0 lbs. 27.6 lbs. 54.0 lbs. 28.0 lbs. 86.0 lbs. 10.0 lbs. 34.0 lbs. 54.0 lbs. 20.0 lbs. 56.0 lbs. 93.0 lbs. 34.0 lbs. 106.0 lbs. 44.0 lbs. 133.0 lbs. 68.2 lbs. 136.4 lbs. 204.6 lbs. 88.0 lbs. 264.0 lbs. 128.0 lbs. Installation ⅜" Manual (PDAM), Complete Design Assistance Manual (CDAM), Hydronic Piping Design Assistance Manual (HPDAM) or AquaSAFE™ Residential Fire Sprinkler Installation Guide for more information. Listings2 Codes Standards cNSFus-fs3; cNSFus-pw; cQAIus P321; UL; CSA; PPI TR-4; ICC-ES; BMEC; CCMC UPC; UMC; NSPC; HUD; UFGS; NPC of Canada; NBC of Canada F2023; ASTM E84; CAN/ULC S102.2; ASTM E119/UL 263; CAN/ULC S101; ASTM E814/ULC S115; CSA B137.5; CSA B214; UL 18213; ULC/ORD-C199P3; AWWA C9044 Related applications Contact information AquaSAFE™ fire safety systems Radiant heating and cooling systems Hydronic piping systems Uponor, Inc. 5925 148th Street West Apple Valley, MN 55124 USA Phone: 800.321.4739 Fax: 952.891.2008 uponorpro.com Uponor Ltd. 6510 Kennedy Road Mississauga, ON L5T 2X4 CANADA Phone: 888.994.7726 Fax: 800.638.9517 uponorpro.com 1ProPEX® is a registered trademark of Uponor, Inc. ProPEX™ is a trademark of Uponor Ltd. 2Visit listing agency’s website for complete information; 3For ½", ¾", 1", 1¼", 1½" and 2" tubing only ProPEX® Ring Submittal information Revision I: Nov. 1, 2018 Project information Technical data Material: Engel-method crosslinked polyethylene (PEX-a) Density: 926 to 940 kg/m3 Degree of crosslinking: 70% to 89% Product information and application use Uponor ProPEX® rings are required to make a proper ProPEX connection.1 The ProPEX ring with stop includes a leading edge chamfer and stop edge.  Description Part number Length I.D. O.D. Weight ⅜" ProPEX Ring with Stop, ½" ProPEX Ring with Stop, ⅝" ProPEX Ring with Stop, ¾" ProPEX Ring with Stop, 1" ProPEX Ring with Stop, 1¼" ProPEX Ring with Stop, 1½" ProPEX Ring with Stop, 2" ProPEX Ring with Stop, 2½" ProPEX Ring with Stop, 3" Q4690512 Q4690625 Q4690756 Q4691000 Q4691250 Q4691500 Q4692000 Q4692500 Q4693000 0.54" 0.63" 0.79" 0.87" 1.10" 1.35" 1.61" 1.97" 2.61" 3.12" 0.63" 0.75" 0.88" 1.13" 1.38" 1.63" 2.14" 2.66" 3.16" 0.74" 0.87" 1.00" 1.13" 1.42" 1.66" 1.91" 2.61" 3.25" 3.87" 0.005 lbs. 0.006 lbs. 0.008 lbs. 0.012 lbs. 0.020 lbs. 0.030 lbs. 0.040 lbs. 0.133 lbs. 0.230 lbs. 0.400 lbs. Installation Square cut the Uponor PEX tubing. Remove excess material. Slide the ProPEX ring over the end of the tubing (maximum 1/16" over-hang for rings without stop). When using the ProPEX ring with stop, slide the ring on the tubing with the chamfered edge first until the end of the tubing contacts the stop edge. Expand the tubing and ring. If using the ProPEX Manual Expander Tool, rotate the tool a quarter turn after each expansion to prevent the formation of grooves. Remove the expansion tool and fully seat the tubing and ring against the shoulder of the fitting. Make ProPEX connections at temperatures above 5°F/-15°C. For more information, refer to the Uponor ProPEX Connections Instructional Guide. Listings2 cNSFus-fs3; cNSFus-pw; cNSFus-rfh; cQAIus; UL; CSA; PPI TR-4; ICC-ES; IAPMO; BMEC; CCMC; cQAIus P321 Codes ICC; IPC; IMC; IRC; UPC; UMC; NSPC; HUD; UFGS; NPC of Canada; NBC of Canada Standards ANSI/NSF 14; ANSI/NSF 61; ASTM F876; ASTM F877; ASTM F1960; ASTM F2023; ASTM E84; CAN/ULC S102.2; ASTM E119/UL 263; CAN/ULC S101; ASTM E814/ULC S115; CSA B137.5; CSA B214; UL 18213; ULC/ORD-C199P3 Related applications Contact information AquaSAFE fire safety systems Hydronic radiant heating and cooling systems Snow melting systems Turf conditioning systems Permafrost prevention systems 5925 148th Street West Apple Valley, MN 55124 USA Phone: 800.321.4739 Fax: 952.891.2008 uponorpro.com Uponor Ltd. 6510 Kennedy Road Mississauga, ON L5T 2X4 CANADA Phone: 888.994.7726 Fax: 800.638.9517 uponorpro.com 1ProPEX® is a registered trademark of Uponor, Inc. ProPEX™ is a trademark of Uponor Ltd. ProPEX® Engineered Polymer (EP) Tee Submittal information Project information Technical data Product information and application use ProPEX® engineered polymer (EP) tees make diverting connections for Uponor crosslinked polyethylene (PEX-a) tubing for use in hot and cold domestic potable water systems, residential fire sprinkler systems and hydronic radiant heating and cooling systems. Each end of the tee is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX® or Wirsbo hePEX™ tubing.1 Note: Branch size is listed last in the part descriptions. Description Part number A B Weight Equivalent length (ft.) length (ft.) Cv through Cv branch ProPEX EP Tee, ½" PEX x ½" PEX x ½" PEX ProPEX EP Tee, ¾" PEX x ¾" PEX x ¾" PEX* ProPEX EP Tee, 1" PEX x 1" PEX x 1" PEX* ProPEX EP Tee, 1¼" PEX x 1¼" PEX x 1¼" PEX* ProPEX EP Tee, 1½" PEX x 1½" PEX x 1½" PEX ProPEX EP Tee, 2" PEX x 2" PEX x 2" PEX ProPEX EP Tee, 2½" PEX x 2½" PEX x 2½" PEX Q4757575 Q4751010 Q4751313 Q4751515 Q4752000 Q4752500 3.30" 4.10" 4.80" 5.80" 7.45" 10.56" 1.94" 2.47" 3.22" 3.82" 4.79" 5.45" 0.05 lbs. 0.07 lbs. 0.15 lbs. 0.25 lbs. 0.38 lbs. 1.14 lbs. 1.5 1.3 3.8 1.8 0.8 2.7 15.6 12.7 8.6 10.6 15.5 22.3 15.7 30.5 34.0 63.7 150.7 197.2 5.4 11.3 23.9 31.0 52.5 81.5 Installation Use the appropriate ProPEX Ring for PEX-a tubing. Refer to the Uponor Professional Plumbing Installation Guide, AquaSAFE™ Residential Fire Sprinkler Installation Guide or Uponor Radiant Installation Handbook for additional information. Standards ASTM E84; ASTM E119; ASTM E814; ASTM F877; ASTM F1960; CAN/CSA B137.5; NSF 14; NSF 61 Codes IBC; IMC; IPC; IRC; NPC of Canada; NSPC; UMC; UPC Listings cNSFus-pw; *cNSFus-pw-fs; cQAIus P321; HUD MR 1269; ICC-ES-PMG-1006; ICC-ES-PMG-1012; *UL 1821; *ULC/ORD-C199P; U.P. Code Related applications Contact information Hydronic radiant heating and cooling systems Snow and ice melting systems Turf conditioning systems Permafrost prevention systems AquaSAFE™ fire safety systems 5925 148th Street West Apple Valley, MN 55124 USA Phone: 800.321.4739 Fax: 952.891.2008 uponorpro.com Uponor Ltd. 6510 Kennedy Road Mississauga, ON L5T 2X4 CANADA Phone: 888.994.7726 Fax: 800.638.9517 uponorpro.com 1ProPEX® is a registered trademark of Uponor Inc. ProPEX™ is a trademark of Uponor Ltd. ProPEX® Engineered Polymer (EP) Reducing Tee (up to 1½") Submittal information Project information Technical data Product information and application use domestic potable water systems, residential fire sprinkler systems and hydronic radiant heating and cooling systems. Each end of the tee is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX® or Wirsbo hePEX™ 1 Note: Description Part number A B Weight Equiv. length (ft.) through Equiv. length (ft.) branch Cv v ProPEX EP Reducing Tee, ½" PEX x ½" PEX x ¾" PEX Q4755575 2.86" 1.76" 0.03 lbs. 1.0 15.6 7.7 5.4 ProPEX EP Reducing Tee, ¾" PEX x ½" PEX x ½" PEX Q4757555 3.10" 1.70" 0.04 lbs. 3.5 6.4 4.6 3.4 ProPEX EP Reducing Tee, ¾" PEX x ¾" PEX x ⅝" PEX ProPEX EP Reducing Tee, ¾" PEX x ¾" PEX x ½" PEX* Q4757550 3.30" 1.70" 0.04 lbs. 2.0 7.6 14.2 3.1 ProPEX EP Reducing Tee, ¾" PEX x ¾" PEX x 1" PEX* Q4757710 3.64" 2.32" 0.08 lbs. 1.5 5.7 15.7 8.7 ProPEX EP Reducing Tee, 1" PEX x ¾" PEX x ¾" PEX* Q4751775 3.90" 2.24" 0.08 lbs. 2.4 16.7 12.8 5.3 ProPEX EP Reducing Tee, 1" PEX x ¾" PEX x 1" PEX* Q4751751 3.90" 2.47" 0.08 lbs. 2.4 15.1 12.9 10.5 ProPEX EP Reducing Tee, 1" PEX x 1" PEX x ¾" PEX* Q4751175 4.10" 2.24" 0.09 lbs. 1.7 6.4 27.8 8.2 ProPEX EP Reducing Tee, 1" PEX x 1" PEX x 1 ¼" PEX* Q4751113 4.38" 2.95" 0.13 lbs. 6.52 5.37 15.0 28.0 ProPEX EP Reducing Tee, 1¼" PEX x ¾" PEX x 1¼" PEX* Q4751373 4.61" 2.88" 0.13 lbs. 2.74 11.91 18.8 12.0 ProPEX EP Reducing Tee, 1¼" PEX x 1" PEX x ¾" PEX* Q4751317 4.50" 2.73" 0.11 lbs. 3.4 5.2 21.0 9.3 ProPEX EP Reducing Tee, 1¼" PEX x 1¼" PEX x ¾" PEX* Q4751337 4.70" 2.73" 0.13 lbs. 2.3 5.7 43.4 8.9 ProPEX EP Reducing Tee, 1¼" PEX x 1¼" PEX x 1" PEX* Q4751331 5.00" 2.97" 0.14 lbs. 4.2 6.3 33.0 15.8 ProPEX EP Reducing Tee, 1½" PEX x 1" PEX x ¾" PEX Q4751517 5.25" 3.06" 0.17 lbs. 4.0 5.1 19.5 9.3 ProPEX EP Reducing Tee, 1½" PEX x 1" PEX x 1" PEX Q4751511 5.25" 3.30" 0.18 lbs. 4.3 6.5 18.9 15.6 ProPEX EP Reducing Tee, 1½" PEX x 1¼" PEX x 1" PEX Q4751531 5.50" 2.85" 0.19 lbs. 3.1 13.1 36.4 11.2 ProPEX EP Reducing Tee, 1½" PEX x 1¼" PEX x 1¼" PEX Q4751533 5.50" 3.15" 0.21 lbs. 2.0 17.7 45.4 17.0 ProPEX EP Reducing Tee, 1½" PEX x 1½" PEX x 1" PEX Q4751551 5.75" 3.30" 0.21 lbs. 3.1 6.9 53.8 15.3 Installation Standards Codes Listings ASTM F877; ASTM F1960; NSPC; UMC; UPC ICC-ES-PMG-1012; *UL 1821; *ULC/ORD-C199P; U.P. Code Related applications Contact information Hydronic radiant heating and cooling systems Snow and ice melting systems Turf conditioning systems Permafrost prevention systems 5925 148th Street West Apple Valley, MN 55124 USA Phone: 800.321.4739 Fax: 952.891.2008 6510 Kennedy Road Mississauga, ON L5T 2X4 CANADA Phone: 888.994.7726 Fax: 800.638.9517 1ProPEX® is a registered trademark of Uponor, Inc. ProPEX™ is a trademark of Uponor Ltd. ProPEX® Engineered Polymer (EP) Elbow Submittal information Project information Technical data pressure): 320°F (160°C) Product information and application use ProPEX® engineered polymer (EP) elbows make 90-degree connections for Uponor crosslinked polyethylene (PEX-a) tubing for use in hot and cold domestic potable water systems, residential fire safety and hydronic radiant heating and cooling systems. Each end of the elbow is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX® or Wirsbo hePEX™ tubing.1 Description Part number A B Weight Equivalent length (ft.)Cv ProPEX EP Elbow, ¾" PEX x ¾" PEX* ProPEX EP Elbow, 1" PEX x 1" PEX* ProPEX EP Elbow, 1¼" PEX x 1¼" PEX* ProPEX EP Elbow, 1½" PEX x 1½" PEX ProPEX EP Elbow, 2" PEX x 2" PEX ProPEX EP Elbow, 2½" PEX x 2½" PEX ProPEX EP Elbow, 3" PEX x 3" PEX ProPEX EP 45 Elbow, 1½" PEX x 1½" PEX ProPEX EP 45 Elbow, 2" PEX x 2" PEX ProPEX EP 45 Elbow, 2½" PEX x 2½" PEX ProPEX EP 45 Elbow, 3" PEX x 3" PEX Q4760750 Q4761000 Q4761250 Q4761500 Q4762000 Q4762500 Q4763000 Q4761515 Q4762020 Q4762525 Q4763030 1.60" 2.10" 2.45" 2.77" 3.76" 4.93" 5.88" 2.32" 2.91" 3.83" 4.48" 1.60" 2.10" 2.45" 2.77" 3.76" 4.93" 5.88" 2.32" 2.91" 3.83" 4.48" 0.03 lbs. 0.07 lbs. 0.11 lbs. 0.18 lbs. 0.30 lbs. 0.85 lbs. 1.44 lbs. 0.13 lbs. 0.32 lbs. 0.65 lbs. 1.07 lbs. 10.8 11.5 10.0 11.5 17.1 20.0 23.2 9.3 8.8 7.0 8.3 6.7 11.9 22.2 29.7 50.2 86.0 125.0 33.1 68.9 136.8 195.5 Installation Standards ASTM E84; ASTM E119; ASTM E814; ASTM F877; ASTM F1960; CAN/CSA B137.5; NSF 14; NSF 61 Codes IBC; IMC; IPC; IRC; NPC of Canada; NSPC; UMC; UPC Listings cNSFus-pw; *cNSFus-pw-fs; cQAIus P321; HUD MR 1269; ICC-ES-PMG-1006; ICC-ES-PMG-1012; *UL 1821; *ULC/ORD-C199P; U.P. Code Related applications Contact information Hydronic radiant heating and cooling systems Snow and ice melting systems Turf conditioning systems Permafrost prevention systems AquaSAFE fire safety systems 5925 148th Street West Apple Valley, MN 55124 USA Phone: 800.321.4739 Fax: 952.891.2008 uponorpro.com Uponor Ltd. 6510 Kennedy Road Mississauga, ON L5T 2X4 CANADA Phone: 888.994.7726 Fax: 800.638.9517 uponorpro.com ProPEX® Fire Sprinkler Adapter Submittal Information Revision B: March 17, 2009 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer’s Representative: Approved By: Technical Data Material: 300 Series Stainless Steel Product Information and Application Use Use the ProPEX® Fire Sprinkler Adapter in conjunction with the appropriate sprinkler to provide a multi-purpose residential fire sprinkler system1. For residential applications, the system is installed with the cold-potable portion of the Uponor plumbing system. Make connections with Uponor ProPEX fittings. These fittings are designed for use only with ¾" or 1" AquaPEX® White tubing in the Uponor AQUASAFE® Looped System. 9 Description Part Number A B C D E Weight ProPEX Fire Sprinkler Adapter, ¾" PEX x ½" FNPT Q7517550 0.75" 1.88" 2.50" 1.82" 1.41" 0.268 lbs. ProPEX Fire Sprinkler Adapter, 1" PEX x ½" FNPT Q7511050 0.75" 1.88" 2.50" 2.06" 1.54" 0.408 lbs. Installation Use appropriate ProPEX Ring for connecting the tubing. Refer to the AquaPEX Installation Handbook or the Uponor AQUASAFE® Installation Guide for additional information. Standards CAN/CSA B137.5; ASTM F877; ASTM F 1960 Codes IPC; UPC; NSPC; IRC; IMC; NPC of Canada Listings ANSI/NSF 14- and 61-certified; U.P. Code; ICC ESR 1099; HUD MR 1269; UL 1821; ULC/ORD - C 199 P Related Applications Contact Information PEX-a Plumbing Systems AQUASAFE Fire Safety Systems Uponor, Inc. 5925 148th Street West Apple Valley, MN 55124 USA Phone: (800) 321-4739 Fax: (952) 891-2008 www.uponor-usa.com Uponor Ltd. 2000 Argentia Rd., Plaza 1, Ste. 200 Mississauga, ON L5N 1W1 CANADA Phone: (888) 994-7726 Fax: (800) 638-9517 www.uponor.ca 1ProPEX® is a registered trademark of Uponor, Inc. ProPEX™ is a trademark of Uponor Ltd. A-PEX Design Services Inc. sales@a-pexdesignservices.com 11112 47th Avenue West Mukilteo, WA 98275 425-493-9680 Job Name : GILMAN WALK - PLAN REDONDO - One Head Calculation (H.12) Drawing : RESIDENTIAL Location : ARLINGTON WA 98223 Remote Area : 1 Contract : 220118-04 Data File : 220118-04 Gilman Walk - Plan Redondo.wx1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services Inc.Page 1 GILMAN WALK - PLAN REDONDO - One Head Calculation (H.12) Date 1/24/2022 HYDRAULIC DESIGN INFORMATION SHEET Name - GILMAN WALK - PLAN REDONDO Date - 01-18-2022 Location - ARLINGTON WA 98223 Building - RESIDENTIAL System No. - 1 Contractor - NW CUSTOM PLUMBING Contract No. - 220118-04 Calculated By - LIBBY BABB Drawing No. - Construction: (X) Combustible ( ) Non-Combustible Ceiling Height OCCUPANCY - RESIDENTIAL S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: (X)1 ( )2 ( )4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 17 Gpm System Type Listed Pres. at Start Point - 12.03Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 18 x 18 ( ) Deluge ( ) PreAction E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make RELIABLE Model LL-RFC49 I Elevation at Highest Outlet - 116 Feet Size 3/8 K-Factor 4.9 G Note: Temperature Rating 155 N Calculation Gpm Required 17 Psi Required 45.85 At Ref Pt STR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: A Date of Test - Rated Cap. T Time of Test - @ Psi E Static (Psi) - 90 Elev. R Residual (Psi) - 20 Other Flow (Gpm) - 500 S Elevation - 100 P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services Inc.Page 2 GILMAN WALK - PLAN REDONDO - One Head Calculation (H.12)Date 1/24/2022 10 20 30 40 E 50 R 60 U 70 S 80 S 90 E 100 R 110 P 120 130 140 150 50 100 150 200 250 300 350 400 450 FLOW ( N ^ 1.85 ) City Water Supply:Demand: C1 C2 C1 - Static Pressure : 90 C2 - Residual Pressure: 20 C2 - Residual Flow : 500 D1 - Elevation : 6.930 D2 - System Flow : 16.995 D2 - System Pressure : 45.854 Hose ( Demand ) : _______ D3 - System Demand : 16.995 Safety Margin : 44.011 D1 D2 Water Supply Curve C Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services Inc.Page 3 GILMAN WALK - PLAN REDONDO - One Head Calculation (H.12)Date 1/24/2022 Fitting Legend Abbrev. Name E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 1 1 1 1 1 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Utb * Aquapex Tee - Branch 2 17 14 9 12 17 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Utr * Aquapex Tee - Run 1 2 2 4 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Fittings Used Summary Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services Inc.Page 4 GILMAN WALK - PLAN REDONDO - One Head Calculation (H.12) Date 1/24/2022 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure STR 90.0 20 500.0 89.866 17.0 45.854 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.12 116.0 4.9 12.03 17.0 H.11 116.0 12.56 T.22 116.0 12.83 T.20 116.0 12.98 T.17 108.0 17.2 H.9 108.0 17.39 T.21 108.0 17.86 T.23 108.0 17.9 S.1 104.0 19.98 PRV 100.0 28.94 MTR 100.0 43.44 STR 100.0 45.85 H.13 116.0 12.36 T.24 116.0 13.01 H.8 116.0 13.02 H.3 116.0 13.11 T.15 116.0 13.14 T.14 108.0 17.2 H.1 108.0 17.38 H.6 108.0 17.57 T.16 108.0 17.74 H.10 116.0 13.03 T.19 116.0 13.04 T.18 116.0 13.06 H.5 116.0 13.08 H.4 116.0 13.11 H.2 108.0 17.2 H.7 108.0 17.2 Flow Summary - NFPA 2007 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services Inc.Page 5 GILMAN WALK - PLAN REDONDO - One Head Calculation (H.12) Date 1/24/2022 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf H.12 116 4.90 7.67 1 Utr 2.0 12.000 150 12.030 to 0.0 2.000 0.0 H.11 116 7.67 0.862 0.0 14.000 0.0380 0.532 Vel = 4.22 H.11 116 0.0 1 Utr 2.0 5.000 150 12.562 to 0.0 2.000 0.0 T.22 116 7.67 0.862 0.0 7.000 0.0380 0.266 Vel = 4.22 T.22 116 0.0 1 Utr 2.0 2.000 150 12.828 to 0.0 2.000 0.0 T.20 116 7.67 0.862 0.0 4.000 0.0382 0.153 Vel = 4.22 T.20 116 -2.57 1 2Utb 34.0 14.000 150 12.981 to 0.0 28.000 3.465 T.17 108 5.1 0.862 0.0 42.000 0.0179 0.752 Vel = 2.80 T.17 108 0.16 1 Utr 2.0 8.000 150 17.198 to 0.0 2.000 0.0 H.9 108 5.26 0.862 0.0 10.000 0.0189 0.189 Vel = 2.89 H.9 108 0.0 1 Utb 17.0 11.000 150 17.387 to 0.0 14.000 0.0 T.21 108 5.26 0.862 0.0 25.000 0.0190 0.474 Vel = 2.89 T.21 108 4.34 1.5 Utr 2.0 2.000 150 17.861 to 0.0 2.000 0.0 T.23 108 9.6 1.244 0.0 4.000 0.0095 0.038 Vel = 2.53 T.23 108 7.40 1.5 T 3.443 9.000 150 17.899 to 0.0 3.443 1.732 S.1 104 17.0 1.244 0.0 12.443 0.0278 0.346 Vel = 4.49 S.1 104 0.0 1.5 2E 3.443 5.000 150 19.977 to 0.0 3.443 8.732 * * Fixed Loss = 7 PRV 100 17.0 1.244 0.0 8.443 0.0278 0.235 Vel = 4.49 PRV 100 0.0 1.5 2E 12.089 50.000 150 28.944 to 0.0 12.089 14.000 * * Fixed Loss = 14 MTR 100 17.0 1.61 0.0 62.089 0.0079 0.492 Vel = 2.68 MTR 100 0.0 1 E 2.336 20.000 150 43.436 to T 5.841 9.345 0.0 STR 100 17.0 0.995 G 1.168 29.345 0.0824 2.418 Vel = 7.01 0.0 STR 17.00 45.854 K Factor = 2.51 H.12 116 9.33 1 0.0 6.000 150 12.030 to 0.0 0.0 0.0 H.13 116 9.33 0.862 0.0 6.000 0.0547 0.328 Vel = 5.13 H.13 116 0.0 1 Utr 2.0 10.000 150 12.358 to 0.0 2.000 0.0 T.24 116 9.33 0.862 0.0 12.000 0.0547 0.656 Vel = 5.13 T.24 116 -1.94 1 2Utb 34.0 12.000 150 13.014 to 0.0 28.000 3.465 T.23 108 7.39 0.862 0.0 40.000 0.0355 1.420 Vel = 4.06 0.0 T.23 7.39 17.899 K Factor = 1.75 T.20 116 2.56 1 Utr 2.0 5.000 150 12.981 to 0.0 2.000 0.0 H.8 116 2.56 0.862 0.0 7.000 0.0050 0.035 Vel = 1.41 Final Calculations - Hazen-Williams - 2007 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services Inc.Page 6 GILMAN WALK - PLAN REDONDO - One Head Calculation (H.12) Date 1/24/2022 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf H.8 116 0.0 1 Utr 2.0 16.000 150 13.016 to 0.0 2.000 0.0 H.3 116 2.56 0.862 0.0 18.000 0.0050 0.090 Vel = 1.41 H.3 116 0.0 1 Utr 2.0 4.000 150 13.106 to 0.0 2.000 0.0 T.15 116 2.56 0.862 0.0 6.000 0.0050 0.030 Vel = 1.41 T.15 116 1.94 1 2Utb 34.0 14.000 150 13.136 to 0.0 28.000 3.465 T.14 108 4.5 0.862 0.0 42.000 0.0142 0.596 Vel = 2.47 T.14 108 -0.16 1 Utr 2.0 12.000 150 17.197 to 0.0 2.000 0.0 H.1 108 4.34 0.862 0.0 14.000 0.0133 0.186 Vel = 2.39 H.1 108 0.0 1 Utr 2.0 12.000 150 17.383 to 0.0 2.000 0.0 H.6 108 4.34 0.862 0.0 14.000 0.0133 0.186 Vel = 2.39 H.6 108 0.0 1 Utr 2.0 11.000 150 17.569 to 0.0 2.000 0.0 T.16 108 4.34 0.862 0.0 13.000 0.0132 0.172 Vel = 2.39 T.16 108 0.0 1 Utr 2.0 7.000 150 17.741 to 0.0 2.000 0.0 T.21 108 4.34 0.862 0.0 9.000 0.0133 0.120 Vel = 2.39 0.0 T.21 4.34 17.861 K Factor = 1.03 T.24 116 1.94 1 Utr 2.0 3.000 150 13.014 to 0.0 2.000 0.0 H.10 116 1.94 0.862 0.0 5.000 0.0028 0.014 Vel = 1.07 H.10 116 0.0 1 Utr 2.0 3.000 150 13.028 to 0.0 2.000 0.0 T.19 116 1.94 0.862 0.0 5.000 0.0030 0.015 Vel = 1.07 T.19 116 0.0 1 Utr 2.0 3.000 150 13.043 to 0.0 2.000 0.0 T.18 116 1.94 0.862 0.0 5.000 0.0030 0.015 Vel = 1.07 T.18 116 0.0 1 Utr 2.0 5.000 150 13.058 to 0.0 2.000 0.0 H.5 116 1.94 0.862 0.0 7.000 0.0030 0.021 Vel = 1.07 H.5 116 0.0 1 Utr 2.0 9.000 150 13.079 to 0.0 2.000 0.0 H.4 116 1.94 0.862 0.0 11.000 0.0030 0.033 Vel = 1.07 H.4 116 0.0 1 Utr 2.0 6.000 150 13.112 to 0.0 2.000 0.0 T.15 116 1.94 0.862 0.0 8.000 0.0030 0.024 Vel = 1.07 0.0 T.15 1.94 13.136 K Factor = 0.54 T.14 108 0.16 1 Utr 2.0 7.000 150 17.197 to 0.0 2.000 0.0 H.2 108 0.16 0.862 0.0 9.000 0 0.0 Vel = 0.09 H.2 108 0.0 1 Utr 2.0 12.000 150 17.197 to 0.0 2.000 0.0 H.7 108 0.16 0.862 0.0 14.000 0 0.0 Vel = 0.09 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services Inc.Page 7 GILMAN WALK - PLAN REDONDO - One Head Calculation (H.12) Date 1/24/2022 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf H.7 108 0.0 1 Utr 2.0 3.000 150 17.197 to 0.0 2.000 0.0 T.17 108 0.16 0.862 0.0 5.000 0.0002 0.001 Vel = 0.09 0.0 T.17 0.16 17.198 K Factor = 0.04 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services Inc. sales@a-pexdesignservices.com 11112 47th Avenue West Mukilteo, WA 98275 425-493-9680 Job Name : GILMAN WALK - PLAN REDONDO - Two Head Calculation (H.5 & H.10) Drawing : RESIDENTIAL Location : ARLINGTON WA 98223 Remote Area : 1 Contract : 220118-04 Data File : 220118-04 Gilman Walk - Plan Redondo.wx2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services Inc.Page 1 GILMAN WALK - PLAN REDONDO - Two Head Calculation (H.5 & H.10) Date 1/24/2022 HYDRAULIC DESIGN INFORMATION SHEET Name - GILMAN WALK - PLAN REDONDO Date - 01-18-2022 Location - ARLINGTON WA 98223 Building - RESIDENTIAL System No. - 1 Contractor - NW CUSTOM PLUMBING Contract No. - 220118-04 Calculated By - LIBBY BABB Drawing No. - Construction: (X) Combustible ( ) Non-Combustible Ceiling Height OCCUPANCY - RESIDENTIAL S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7.04 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make RELIABLE Model LL-RFC49 I Elevation at Highest Outlet - 116 Feet Size 3/8 K-Factor 4.9 G Note: Temperature Rating 155 N Calculation Gpm Required 26.0988 Psi Required 46.88 At Ref Pt STR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: A Date of Test - Rated Cap. T Time of Test - @ Psi E Static (Psi) - 90 Elev. R Residual (Psi) - 20 Other Flow (Gpm) - 500 S Elevation - 100 P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services Inc.Page 2 GILMAN WALK - PLAN REDONDO - Two Head Calculation (H.5 & H.10)Date 1/24/2022 10 20 30 40 E 50 R 60 U 70 S 80 S 90 E 100 R 110 P 120 130 140 150 50 100 150 200 250 300 350 400 450 FLOW ( N ^ 1.85 ) City Water Supply:Demand: C1 C2 C1 - Static Pressure : 90 C2 - Residual Pressure: 20 C2 - Residual Flow : 500 D1 - Elevation : 6.930 D2 - System Flow : 26.099 D2 - System Pressure : 46.878 Hose ( Demand ) : _______ D3 - System Demand : 26.099 Safety Margin : 42.825 D1 D2 Water Supply Curve C Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services Inc.Page 3 GILMAN WALK - PLAN REDONDO - Two Head Calculation (H.5 & H.10)Date 1/24/2022 Fitting Legend Abbrev. Name E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 1 1 1 1 1 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Utb * Aquapex Tee - Branch 2 17 14 9 12 17 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Utr * Aquapex Tee - Run 1 2 2 4 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Fittings Used Summary Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services Inc.Page 4 GILMAN WALK - PLAN REDONDO - Two Head Calculation (H.5 & H.10) Date 1/24/2022 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure STR 90.0 20 500.0 89.703 26.1 46.878 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.5 116.0 4.9 7.04 13.0 H.4 116.0 7.74 T.15 116.0 8.25 T.14 108.0 13.21 H.1 108.0 13.6 H.6 108.0 14.0 T.16 108.0 14.36 T.21 108.0 14.61 T.23 108.0 14.7 S.1 104.0 17.19 PRV 100.0 26.44 MTR 100.0 41.53 STR 100.0 46.88 T.18 116.0 7.08 T.19 116.0 7.11 H.10 116.0 4.9 7.14 13.1 T.24 116.0 7.88 H.13 116.0 8.04 H.12 116.0 8.11 H.11 116.0 8.29 T.22 116.0 8.38 T.20 116.0 8.43 T.17 108.0 13.23 H.9 108.0 13.62 H.3 116.0 8.28 H.8 116.0 8.39 H.2 108.0 13.21 H.7 108.0 13.22 Flow Summary - NFPA 2007 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services Inc.Page 5 GILMAN WALK - PLAN REDONDO - Two Head Calculation (H.5 & H.10) Date 1/24/2022 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf H.5 116 4.90 10.13 1 Utr 2.0 9.000 150 7.040 to 0.0 2.000 0.0 H.4 116 10.13 0.862 0.0 11.000 0.0637 0.701 Vel = 5.57 H.4 116 0.0 1 Utr 2.0 6.000 150 7.741 to 0.0 2.000 0.0 T.15 116 10.13 0.862 0.0 8.000 0.0636 0.509 Vel = 5.57 T.15 116 -2.74 1 2Utb 34.0 14.000 150 8.250 to 0.0 28.000 3.465 T.14 108 7.39 0.862 0.0 42.000 0.0355 1.492 Vel = 4.06 T.14 108 -0.88 1 Utr 2.0 12.000 150 13.207 to 0.0 2.000 0.0 H.1 108 6.51 0.862 0.0 14.000 0.0281 0.394 Vel = 3.58 H.1 108 0.0 1 Utr 2.0 12.000 150 13.601 to 0.0 2.000 0.0 H.6 108 6.51 0.862 0.0 14.000 0.0281 0.394 Vel = 3.58 H.6 108 0.0 1 Utr 2.0 11.000 150 13.995 to 0.0 2.000 0.0 T.16 108 6.51 0.862 0.0 13.000 0.0281 0.365 Vel = 3.58 T.16 108 0.0 1 Utr 2.0 7.000 150 14.360 to 0.0 2.000 0.0 T.21 108 6.51 0.862 0.0 9.000 0.0282 0.254 Vel = 3.58 T.21 108 7.85 1.5 Utr 2.0 2.000 150 14.614 to 0.0 2.000 0.0 T.23 108 14.36 1.244 0.0 4.000 0.0202 0.081 Vel = 3.79 T.23 108 11.74 1.5 T 3.443 9.000 150 14.695 to 0.0 3.443 1.732 S.1 104 26.1 1.244 0.0 12.443 0.0615 0.765 Vel = 6.89 S.1 104 0.0 1.5 2E 3.443 5.000 150 17.192 to 0.0 3.443 8.732 * * Fixed Loss = 7 PRV 100 26.1 1.244 0.0 8.443 0.0615 0.519 Vel = 6.89 PRV 100 0.0 1.5 2E 12.089 50.000 150 26.443 to 0.0 12.089 14.000 * * Fixed Loss = 14 MTR 100 26.1 1.61 0.0 62.089 0.0175 1.086 Vel = 4.11 MTR 100 0.0 1 E 2.336 20.000 150 41.529 to T 5.841 9.345 0.0 STR 100 26.1 0.995 G 1.168 29.345 0.1823 5.349 Vel = 10.77 0.0 STR 26.10 46.878 K Factor = 3.81 H.5 116 2.87 1 Utr 2.0 5.000 150 7.040 to 0.0 2.000 0.0 T.18 116 2.87 0.862 0.0 7.000 0.0061 0.043 Vel = 1.58 T.18 116 0.0 1 Utr 2.0 3.000 150 7.083 to 0.0 2.000 0.0 T.19 116 2.87 0.862 0.0 5.000 0.0062 0.031 Vel = 1.58 T.19 116 0.0 1 Utr 2.0 3.000 150 7.114 to 0.0 2.000 0.0 H.10 116 2.87 0.862 0.0 5.000 0.0062 0.031 Vel = 1.58 H.10 116 4.90 13.10 1 Utr 2.0 3.000 150 7.145 to 0.0 2.000 0.0 T.24 116 15.97 0.862 0.0 5.000 0.1476 0.738 Vel = 8.78 Final Calculations - Hazen-Williams - 2007 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services Inc.Page 6 GILMAN WALK - PLAN REDONDO - Two Head Calculation (H.5 & H.10) Date 1/24/2022 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf T.24 116 -4.23 1 2Utb 34.0 12.000 150 7.883 to 0.0 28.000 3.465 T.23 108 11.74 0.862 0.0 40.000 0.0837 3.347 Vel = 6.45 0.0 T.23 11.74 14.695 K Factor = 3.06 T.24 116 4.22 1 Utr 2.0 10.000 150 7.883 to 0.0 2.000 0.0 H.13 116 4.22 0.862 0.0 12.000 0.0127 0.152 Vel = 2.32 H.13 116 0.0 1 0.0 6.000 150 8.035 to 0.0 0.0 0.0 H.12 116 4.22 0.862 0.0 6.000 0.0125 0.075 Vel = 2.32 H.12 116 0.0 1 Utr 2.0 12.000 150 8.110 to 0.0 2.000 0.0 H.11 116 4.22 0.862 0.0 14.000 0.0126 0.177 Vel = 2.32 H.11 116 0.0 1 Utr 2.0 5.000 150 8.287 to 0.0 2.000 0.0 T.22 116 4.22 0.862 0.0 7.000 0.0126 0.088 Vel = 2.32 T.22 116 0.0 1 Utr 2.0 2.000 150 8.375 to 0.0 2.000 0.0 T.20 116 4.22 0.862 0.0 4.000 0.0127 0.051 Vel = 2.32 T.20 116 2.74 1 2Utb 34.0 14.000 150 8.426 to 0.0 28.000 3.465 T.17 108 6.96 0.862 0.0 42.000 0.0318 1.336 Vel = 3.83 T.17 108 0.88 1 Utr 2.0 8.000 150 13.227 to 0.0 2.000 0.0 H.9 108 7.84 0.862 0.0 10.000 0.0396 0.396 Vel = 4.31 H.9 108 0.0 1 Utb 17.0 11.000 150 13.623 to 0.0 14.000 0.0 T.21 108 7.84 0.862 0.0 25.000 0.0396 0.991 Vel = 4.31 0.0 T.21 7.84 14.614 K Factor = 2.05 T.15 116 2.74 1 Utr 2.0 4.000 150 8.250 to 0.0 2.000 0.0 H.3 116 2.74 0.862 0.0 6.000 0.0057 0.034 Vel = 1.51 H.3 116 0.0 1 Utr 2.0 16.000 150 8.284 to 0.0 2.000 0.0 H.8 116 2.74 0.862 0.0 18.000 0.0057 0.102 Vel = 1.51 H.8 116 0.0 1 Utr 2.0 5.000 150 8.386 to 0.0 2.000 0.0 T.20 116 2.74 0.862 0.0 7.000 0.0057 0.040 Vel = 1.51 0.0 T.20 2.74 8.426 K Factor = 0.94 T.14 108 0.88 1 Utr 2.0 7.000 150 13.207 to 0.0 2.000 0.0 H.2 108 0.88 0.862 0.0 9.000 0.0008 0.007 Vel = 0.48 H.2 108 0.0 1 Utr 2.0 12.000 150 13.214 to 0.0 2.000 0.0 H.7 108 0.88 0.862 0.0 14.000 0.0006 0.009 Vel = 0.48 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services Inc.Page 7 GILMAN WALK - PLAN REDONDO - Two Head Calculation (H.5 & H.10) Date 1/24/2022 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf H.7 108 0.0 1 Utr 2.0 3.000 150 13.223 to 0.0 2.000 0.0 T.17 108 0.88 0.862 0.0 5.000 0.0008 0.004 Vel = 0.48 0.0 T.17 0.88 13.227 K Factor = 0.24 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PLAN REVIEW FEE PERMIT FEE PRO/TECH FEE TOTALS % SF Const Type # of heads Valuation 1358 VB 88.16$ 450.00$ 538.16$ 22.55% 14 heads 1358 VB 88.16$ 450.00$ 538.16$ 22.55% 14 heads 1520 VB 101.14$ 450.00$ 25.00$ 576.14$ 25.87% 13 heads 1719 VB 113.50$ 450.00$ 563.50$ 29.03% 16 heads Total Valuation 4597 25,248.13$ 390.96$ 1,800.00$ 25.00$ 2,215.96$ 100% 390.96$ DUE AT TIME OF SUBMITTAL TOTAL FEES 2,215.96$ 1,825.00$ DUE AT PERMIT ISSUANCE FOURPLEX PERMIT FEES GILMAN WALK FOURPLEX FIRE PERMIT FEES