HomeMy WebLinkAbout501 E Division St Unit A_BLD6209_2025 RESIDENTIAL MECHANICAL APPLICATION
Community and Economic Development
City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551
This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping.
Please fill out all pages of this application and include all information.
Type of Permit: ï² New Installation ï² Addition/Alteration/Repair ï² Gas Piping
501 E Divison St #A 2710
Property Address: Project Valuation:
Lot #: Parcel ID No.: Preferred Contact: ï² Owner ï² Contractor
Gas water heater replacement
Project Description:
Owner Name: Andrew McGuire Home No.:
Email Address: amac22@live.com Cell No.: 425-512-5151
501 E Divison St #A Arlington WA 98223
Mailing Address: City: State: Zip:
Contractor Name: Fast Water Heater Office No.: 425-298-6968
Email Address: permits@fastwaterheater.com Cell No.:
Mailing Address: 16120 Redmond-Woodinville RD NE #15 City: Woodinville State: WA Zip: 98072
L&I Contractor License Number: FASTWWH948BC Expiration Date: 1/4/2026
• New gas piping requires a pressure test hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper Combustion air and venting required for all appliances
• A shut-off valve is required within 6 feet of all appliances
Gas Piping Information ï² Not Applicable
ï² CSST ï²Brass ï²Other
Proposed Piping Material:
ï²Black Steel ï²Galvanized Steel _______________________________________
Proposed Piping Size: ï²Â½â€ ï² â…â€ ï² Â¾â€ ï² 1â€ ï² 1Â½â€ ï² 2â€
Distance from Meter to furthest Appliance: Total BTU’s of all Appliances:
Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan
review per Table 4-8 may be required for certain permits)
Type of Fixture No. of Cost per Unit Subtotal Model No.
Units
Additional Plan Review fees x $ 75.00 =
Air Conditioning Unit ≤ 100 Btu/h x $ 15.00 =
Air Conditioning Unit > 100 Btu/h x $ 25.00 =
Air Conditioning Unit > 500 Btu/hp x $ 50.00 =
Air Handling Units x $ 15.00 =
Base Mechanical Fee 1 x $ 25.00 = $ 25.00
Boiler <100Btu/h >3hp x $ 15.00 =
REV03.2022 Page 1 of 3
Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan
review per Table 4-8 may be required for certain permits)
Boiler >1 million Btu/h<50hp x $ 25.00 =
Boiler >1.5 million Btu/h<50hp x $ 50.00 =
Boiler >100Btu/h 3-15hp x $ 15.00 =
Boiler >500Btu/h 15-30hp x $ 25.00 =
Commercial Hoods -Type I x $ 25.00 =
Commercial Hoods -Type II x $50.00 =
Diffusers x $ 15.00 =
Dryer Ducting x $ 15.00 =
Ductwork (drawings required) x $ 25.00 =
Evaporative Coolers x $ 15.00 =
Exhaust/Ventilation Fans x $ 15.00 =
Fireplace/Insert/Stove x $ 15.00 =
Forced Air Heat ≤100 Btu/h x $ 15.00 =
Forced Air Heat >100 Btu/h x $ 25.00 =
Gas Clothes Dryer x $ 15.00 =
Gas Fired Air Conditioning Unit ≤ 100 Btu/h x $ 15.00 =
Gas Fired Air Conditioning Unit > 100 Btu/h x $ 25.00 =
Gas Fired Air Conditioning Unit > 500 Btu/hp x $ 50.00 =
Gas Piping ≤ 5 units x $ 15.00 =
Gas Piping for each additional unit > 5 x $ 2.00 =
Heat Exchangers x $ 15.00 =
Heat Pump-Condensing Unit x $ 25.00 =
Hot Water Heat Coils x $ 15.00 =
Miscellaneous Appliance - regulated by $ 15.00
x =
mechanical code, not otherwise specified
Package Units ≤ 100 Btu / > 100 Btu x $ 25.00/$50.00 =
Range/Cook top-Gas Fired x $ 15.00 =
Refrigeration Unit ≤100Btu/h x $ 15.00 =
Refrigeration Unit >100Btu/h x $ 25.00 =
Refrigeration. Unit >500Btu/h x $ 50.00 =
Re-inspection fee x $ 75.00 =
Residential Range Hood x $ 15.00 =
Unit Heaters ≤ 100 Btu/h x $ 15.00 =
Unit Heaters >100 Btu/h x $ 25.00 =
Variable Air Volume Boxes (part of Air $ 10.00
x =
Conditioning System)
Wall Heaters - Gas Fired x $ 25.00 =
Water Heater - Gas Fired 1 x $ 25.00 = 25
Permit Fee
Inspection Fee $75.00
Processing/Technology Fee $25.00
Total
I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of
the above described property will be in accordance with the laws, rules and regulation of the State of Washington.
Ryan Ridley 10/28/2024
Signature Print Name Date
REV2.2024 Page 2 of 3
PRESSURE PIPING SCHEMATIC
COMPLETE FOR GAS PIPING ONLY
ï² SCHEMATIC IS TO SCALE ï² SCHEMATIC NOT TO SCALE
Show Pipe Size(s) and Length(s) from meter to all appliances
NOTE: Any interior pressure regulators must be indicated
REV2.2024 Page 3 of 3
PERFORMANCE®
The PERFORMANCE® atmospheric
gas water heaters feature a diagnostic
gas valve and a six-year warranty
Efficiency Longer Life
n .58 - .66 UEF n Premium grade anode rod provides
long-lasting tank protection NEW! Side Water Connections
Performance on Select Models
Plus…
n FHR: 55 - 97 gallons
n Side water connections for space
n Recovery: Up to 51 GPH at a
heating applications available on
90° F rise, depending on model
select models
Diagnostic Valve
n Easy to light – no matches required
n Self powered diagnostic
n Temperature and pressure relief valve
gas control valve for
included
improved monitoring
and service n Factory installed temperature and
pressure relief valve on select models
Low Emissions
n Low lead compliant
n Eco-friendly burner, low NOx design
n Standard replacement parts
ostic va
n Meets 40 ng/J NOx requirements iagn lve
Warranty D
Maintenance Free
n 6-Year limited warranty for tank
Burner System and parts, 1-year full in-home labor
n Exclusive air/fuel shut-off device warranty*
n Maintenance free – no filter to clean *See written warranty for complete details
n Disables the heater in the presence of Units meet or exceed ANSI requirements and have
flammable vapor accumulation been tested according to D.O.E. procedures. Units
meet or exceed the energy efficiency requirements
of NAECA, ASHRAE standard 90, ICC Code and all
state energy efficiency performance criteria. PERFORMANCE
Atmospheric
29, 30, 40, 50 and 55-Gallon
Combustion Shut-off System Flame Arrestor Plate
Capacities
Up to 50,000 BTU/h
Maintenance Free
†LEED Point = 1
See specifications chart on back.
12/23 FORM NO. THD-PGRH N Rev. 12
PERFORMANCE®
Atmospheric Gas Specifications
Ht. to Water Water Uniform
Nominal Rated Gas Input Recovery First Hour Ht. to Tank Gas Vent Conn. Ht. to Side Conn. Ship Energy
Gallon Gallon Model in Thous. in G.P.H. Rating Vent Height Diam. Conn. Size Center T&P Valve Size Weight Factor
Fuel Type Description Capacity Capacity Number Btu/h 90° F Rise (Gallons) A B C D E F G H (LBS)
(UEF)
Performance - Self Powered Diagnostic Control - High Demand
Natural Gas Tall 55 55 XG55T06EC50UO†50 51 97 59-1/8 55-7/8 23-3/4 14-1/4 4 8 48-3/4 3/4 175
0.62
Liquid Propane Tall 55 55 XP55T06EC45UO†45 46 97 59-1/8 55-7/8 23-3/4 14-1/4 4 8 48-3/4 3/4 175
0.62
Performance - Self Powered Diagnostic Control - High Efficiency
Natural Gas Tall 50 48 XG50T06HE40UO†40 40.4 77 62-3/4 59-1/4 21-1/2 14-1/2 3 or 4 8 52-1/2 3/4 165
0.64
Natural Gas Tall 50 48 XG50T06TH40U0* 40 40.4 75 62-3/4 59-1/4 21-1/2 14-1/2 3 or 4 8 52-1/2 3/4 165
0.64
Natural Gas Tall 40 38 XG40T06TH40U0* 40 40.4 84 63-1/4 60 19-1/2 14 3 or 4 8 53-1/2 3/4 135
0.66
Natural Gas Short 40 39 XG40S06HE38UO†38 38.4 69 53-3/4 50-1/4 21-1/2 14-1/2 3 8 44 3/4 125
0.59
Liquid Propane Tall 50 48 XP50T06HE36UO†36 36.4 77 62-3/4 59-1/4 21-1/2 14-1/2 3 or 4 8 52-1/2 3/4 165
0.64
Liquid Propane Tall 40 38 XP40T06HE36U0†36 36.3 84 63-1/4 60 19-1/2 14 3 or 4 8 53-1/2 3/4 135
0.66
Liquid Propane Short 40 39 XP40S06HE36UO†36 36.4 69 53-3/4 50-1/4 21-1/2 14-1/2 3 8 44 3/4 125
0.59
Performance - Self Powered Diagnostic Control
Natural Gas Tall 50 48 XG50T06EC38U1 38 38.4 85 61-1/4 58-1/4 20-1/2 14-1/4 3 or 4 8 51-3/8 3/4 140
0.63
Natural Gas Tall 50 48 XG50T06TC38U1* 38 38.4 85 61-1/4 58-1/4 20-1/2 14-1/4 3 or 4 8 51-3/8 3/4 140
0.63
Natural Gas Short 50 48 XG50S06EC40U1 40 40.4 86 54-1/4 51 23-3/4 14-1/4 3 or 4 8 44 3/4 186
0.64
Natural Gas Tall 40 38 XG40T06EC36U1 36 36.4 68 61-1/2 58-1/2 19 14-1/4 3 or 4 8 52-1/4 3/4 127
0.58
Natural Gas Tall 40 38 XG40T06TC36U1* 36 36.4 68 61-1/2 58-1/2 19 14-1/4 3 or 4 8 52-1/4 3/4 127
0.58
Natural Gas Short 40 39 XG40S06EC34UO 34 34.3 64 52-1/8 49-1/4 21 14-1/4 3 or 4 8 42-3/4 3/4 120
0.58
Natural Gas Short 30 29 XG30S06EC30U1 30 30.3 55 49-7/8 46-1/4 19-3/4 14-1/4 3 or 4 8 40-3/8 3/4 112
0.60
Natural Gas Tall 29 28 XG29T06EC32U1 32 32.3 62 59-3/4 56-1/2 16-1/2 14-1/4 3 or 4 8 50-3/4 3/4 110
0.60
Liquid Propane Tall 50 48 XP50T06EC36U1 36 36.4 85 61-1/4 58-1/4 20-1/2 14-1/4 3 or 4 8 51-3/8 3/4 125
0.63
Liquid Propane Tall 40 38 XP40T06EC32U1 32 32.3 69 61-1/2 58-1/2 18-1/2 14-1/4 3 or 4 8 52-1/4 3/4 125
0.61
Liquid Propane Tall 29 28 XP29T06EC30U1 30 30.3 62 59-3/4 56-1/2 16-1/2 14-1/4 3 or 4 8 50-3/4 3/4 110
0.60
Performance – Side Water Connections
Natural Gas Tall 48 46 XG50T06ECX58U0 H 53 61 105 61-3/4 58-1/2 21-3/4 14-3/8 4 11 51-7/8 3/4 162
0.62
Natural Gas Tall 48 46 XG50T06ECX58U0 58 61 105 61-3/4 58-1/2 21-3/4 14-3/8 4 11 51-7/8 3/4 162
0.62
Liquid Propane Tall 48 46 XP50T06ECX54U0 54 55 105 61-3/4 58-1/2 21-3/4 14-3/8 4 11 51-7/8 3/4 162
0.62
Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements.
*Models with installed top T&P.
FLUE ANODE ROD FLUE ANODE ROD FLUE ANODE ROD
†H H H
LEED Point = 1 HOT H HOTH H HOT COLD
WATER COLD COLD WATER WATER
WATER WATER WATER CONNECTION CONNECTION
CONNECTION CONNECTION
CONNECTION CONNECTION
F F F INSTALLED
E E E T&P VALVE
3/4" N.P.T. 3/4" N.P.T. TOP T&P
RELIEF RELIEF 1-1/2" ABOVE
VALVE VALVE TOP PAN
TO
OPENING OPENING CENTER OF
OPENING
C C
C SIDE
A B A B TAPS G A B
1/2" G 1/2" 52-1/2" 1/2"
D D 20" D
Side T&P Models Side Water Connection Models Top T&P Models
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100
Roswell, Georgia 30076 • www.rheem.com
12/23 FORM NO.
THD-PGRH N Rev. 12
!"!
#$%& '()*+,
-.%/& 0123413,+",13,+
-.%/-5566 ,789:7;4997*:<*==,917>?
-.%/@A@B@C 4997*:<*==,D4 E
A#/% F1:*7=,F
G#/ ?
H. I,+8*32JK123L13,+M,13,+N'98
B%##OP#Q ,89<,,I=1',? R1==9:R12L13,+M,13,+*:R1+1R,
S.T#/ E N
BUTV
&TW#OB#6
A#/6T%#/ XY
Z%%T/%[#T ;\],2*7,:3*1=
^A#5
^66T5
H_6 ?
V# !"!
BT6 `a
-66b/5# 8,+,2*11L=*2
#
a1+',=> 77+,22,R1=,2'+*I3*9:cL:,+18, cL:,+aM9:, d9:*:R
? Xce
f!"gg ea`
A#/%#6
!9:3+1'39+a+*81+F!9:31'3aM9:,77+,22!9:3+1'39+FI,*',:2, *',:2,>
E?!g
04 ae Y(
?N \ NE ? ag4hD3, !c ? ?
" !c!c
!
E?!g
04 ae Y( Yci
?N \ NE ? ag4hD3, 044" Y!
" !c!c e
!
V6
!
" # $ %&& '
(' (' )* +
,-./0 1234536
7../89:; <:..:=>
%
?@+ ABCDECFG HIJKCL
?@+ MIN OPJKQ RISCEIFLCTD UIVWTFCVTD XYYDCVTLCPF
Z/[\:].>
' !
' !
^! ( _`
?@+ ?
?ab?a@+
?@+ ?ab?a@+
%c +
de.>./];f]g h/0/]8: 16566
i-.:>
( ' !`
+ j # #'ck
b j # #'ck
lm0-/;:; nf0:>
?@+ oopqrstuQosovusoqwAxyrospwzSSBIEHIJKCL{YE|
?@+ sqVTIVI|VVNo|vIqusIqvpI}oN|trvuVw}s~pv}twTYYDCVTLCPF{YE|
?@+ }}IIE|N}IVuvp|INp}tTqVI~sqtssrTvwtsqrpsvoQvNNTQvETtQN}IVQT~pvrquvq|N~{YE|