Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
7929 172nd Pl Ne_BLD5123_2025
Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551 Page 1 of 1 Permit Number: Permit Type: Address/Parcel: Completed (Month/Year): Land Use Notice of Decision Staff Report Application Narrative Legal Description Vicinity Map Site Plan Landscape Plan Complete Streets Checklist Traffic Impact Analysis Snohomish County Traffic Mitigation Offer WSDOT Traffic Offer Form Tree Survey Stormwater Drainage Report Geotech Report Critical Area Evaluation Form SEPA Checklist Public Notice Material Noticing and Related Documents Water / Sewer Availability Certificate Unanticipated Discovery Plan Form Aerial Photo of Site Proposed Building Materials Lighting Plans and Lighting Cut Sheets Color Elevations Design Matrix Plat Map Title Report Lot Closures Preliminary Civil Plans Archaeological Survey o Confidential Documents. Contact the City to obtain. Topography (Existing Conditions) CC&R’s Deeds / Easements / Conveyances /Dedications Developer’s Agreement Recorded Copies Bonding or Assignment of Funds o Confidential Documents. Contact the City to obtain. Letters and Project Documents Other: Civil Issued Permit Application Other Applications Construction Calculation Worksheet Approved Plans Review Comment Form Letters and Project Documents Other Agency Permits Reports: o Drainage Report Pg: o Stormwater Pg: o Geotech Pg: o All Other Reports SEPA and Noticing Materials Inspections As-Builts Other: Building Issued Permit Application Additional Applications Approved Plans Site Plan Letters and Project Documents Calculations Project Specification Manuals Reports Certificate of Occupancy Inspections Other: BLD5123 Residential Mechanical 7929 172nd Pl Ne October 2023 ✔ ✔ ✔ ✔ TAG:______________________________ SSAAFFEETTYY WWAARRNNIINNGG Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. August 2016 4A7A3030H-SUB-1C-EN Split System Cooling 2.5 Ton 4A7A3030H1000N Submittal 2 4A7A3030H-SUB-1C-EN Model Base A B C D E F G H J K 4A7A3030H 2 730 (28–3/4) 724 (28–1/2) 651 (25–5/8)3/4 3/8 137 (5–3/8) 65 (2–5/8) 210 (8–1/4) 57 (2–1/4) 457 (18) SOUND POWER LEVEL Model A-Weighted Sound Power Level [dB(A)] Full Octave Sound Power [dB] 63 Hz*125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A7A3030G 72 69.9 69.6 69.1 68.6 68.7 60.9 56.2 48.9 Note:Rated in accordance with AHRI Standard 270–2008 *For reference only 4A7A3030H-SUB-1C-EN 3 Product Specifications OUTDOOR UNIT (a)(b)4A7A3030H1000N POWER CONNS.—V/PH/HZ (c)208/230/1/60 MIN.BRCH.CIR.AMPACITY 16 BR.CIR.PROT.RTG.—MAX.(AMPS)25 COMPRESSOR DURATION™-SCROLL NO.USED —NO.STAGES 1 —1 VOLTS/PH/HZ 208/230/1/60 R.L.AMPS (d)—L.R.AMPS 12.3 —63 FACTORY INSTALLED START COMPONENTS (e)NO INSULATION/SOUND BLANKET NO COMPRESSOR HEAT NO OUTDOOR FAN PROPELLER DIA.(IN.)—NO.USED 18.9 —1 TYPE DRIVE —NO.SPEEDS DIRECT —1 CFM @ 0.0 IN.W.G.(f)2000 NO.MOTORS —HP 1 —1/8 MOTOR SPEED R.P.M.825 VOLTS/PH/HZ 200/230/1/60 F.L.AMPS 0.9 OUTDOOR COIL —TYPE SPINE FIN™ ROWS —F.P.I.1 —24 FACE AREA (SQ.FT.)12.89 TUBE SIZE (IN.)3/8 REFRIGERANT LBS.—R-410A (O.D.UNIT)(g)4 LBS.,10 OZ FACTORY SUPPLIED YES LINE SIZE —IN.O.D.GAS (h)3/4 LINE SIZE —IN.O.D.LIQ.3/8 CHARGING SPECIFICATIONS SUBCOOLING 10°F DIMENSIONS H X W X D CRATED (IN.)34 x 27 x 29 WEIGHT SHIPPING (LBS.)157 NET (LBS.)137 (a)Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program,which is based on AHRI standard 210/240. (b)Rated in accordance with AHRI standard 270. (c)Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers or fuses. (d)This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the branch circuit selection current. (e)No means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter. (f)Standard Air —Dry Coil —Outdoor (g)This value approximate.For more precise value see unit nameplate. (h)Max.linear length 60 ft.;Max.lift —Suction 60 ft.;Max.lift —Liquid 60 ft.For greater length consult refrigerant piping software Pub.No. 32–3312–0*(*denotes latest revision). Mechanical Specification Options GGeenneerraall The Outdoor Units are fully charged from the factory for up to 15 feet of piping.This unit is designed to operate at outdoor ambient temperatures as high as 115°F.Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified.The unit is certified to UL 1995.Exterior is designed for outdoor application. CCaassiinngg Unit casing is constructed of heavy gauge,galvanized steel and painted with a weather-resistant powder paint finish on all louvered panels and the fan top panel.The corner panels are prepainted.All panels are subjected to our 1,00 0 hour salt spray test .The base is made of a CMBP-G30 weatherproof material to resist corrosion. RReeffrriiggeerraanntt CCoonnttrroollss Refrigeration system controls include condenser fan, compressor contactor and high pressure switch.High and low pressure controls are inherent to the compressor.A factory supplied liquid line drier is standard.Some models may require field installation. CCoommpprreessssoorr The compressor features internal over temperature, pressure protection and total dipped hermetic motor. Other features include:Centrifugal oil pump and low vibration and noise. CCoonnddeennsseerr CCooiill The outdoor coil provides low airflow resistance and efficient heat transfer.The coil is protected on all four sides by louvered panels. LLooww AAmmbbiieenntt CCoooolliinngg As manufactured,this system has a cooling capacity to 55°F.The addition of an evaporator defrost control permits operation to 40°F.The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. TThheerrmmoossttaattss—Cooling only and heat/cooling (manual and automatic change over).Sub-base to match thermostat and locking thermostat cover. EEvvaappoorraattoorr DDeeffrroosstt CCoonnttrrooll —See Low Ambient Cooling. Ingersoll Rand (NYSE:IR)advances the quality of life by creating comfortable,sustainable and efficient environments. Our people and our family of brands —including Club Car®,Ingersoll Rand®,Thermo King®and Trane®—work together to enhance the quality and comfort of air in homes and buildings;transport and protect food and perishables;and increase industrial productivity and efficiency.We are a global business committed to a world of sustainable progress and enduring results.For more information,visit www.ingersollrand.com. Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2012 Ingersoll Rand All rights reserved 4A7A3030H-SUB-1C-EN 29 Aug 2016 Supersedes 4A7A3030G-SUB-1B-EN (November 2013) SUBMITTAL © 2015 Ingersoll Rand TAG: _________________________________ Downflow / Horizontal Gas Furnace - Variable Speed - 2 Stage Heat TDD2B080A9V3VA ADD2B080A9V3VA 7/8" HOLE WITH PLUG 1-1/2" DIA. GAS CONNECTION (ALTERNATE) 7/8" DIA. HOLES ELECTRICAL CONNECTION 1-5/8" DIA. HOLE WITH PLUG GAS CONNECTION (ALT) 40" 20-1/4" 10" 5-5/16"1/2" 3-3/4” 19" 8-1/4" 3/4" 28" 19-5/8" 5/8" 4-1/8" 16-1/4" 17-1/2" 16" 3/4" 3/4" 9-5/8" 2-1/8" 2-1/8" 12-3/8" 10" 5/8" FLUE OPENING 24-1/2" 29-1/2" 5" 7" SIDE PANEL CUTOUT FOR HORIZONTAL VENTING THROUGH THE CABINET 1/2" 4" O 3-15/16" 3-3/8 3-1/2 31 5" O SIDE PANEL CUTOUT FOR HORIZONTAL VENTING THROUGH THE CABINET 7-3/8" 1-5/8” HOLE WITH PLUG 1-5/8” HOLE WITH PLUG 1-5/8” HOLE WITH PLUG 1-5/8” HOLE WITH PLUG TDD2B080A9V-SUB-1B *DD2B080A9V3VA FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE S3-1 S3-2 S3-3 S3-4 0.1 0.3 0.5 0.7 0.9 2.5 LOW (350 CFM/TON)OFF ON OFF ON CFM WATTS 840 105 830 135 830 160 815 220 750 225 NORMAL (400 CFM/TON)OFF ON OFF OFF CFM WATTS 970 140 950 170 940 210 925 245 900 270 HIGH (450 CFM/TON)OFF ON ON OFF CFM WATTS 1085 185 1060 220 1045 260 1015 300 1000 325 3.0 LOW (350 CFM/TON)ON OFF OFF ON CFM WATTS 1015 155 995 190 990 230 970 260 920 285 NORMAL (400 CFM/TON)ON OFF OFF OFF CFM WATTS 1150 215 1140 250 1120 305 1100 335 1085 370 HIGH (450 CFM/TON)ON OFF ON OFF CFM WATTS 1290 300 1290 340 1270 390 1260 425 1235 475 3.5 ** LOW (350 CFM/TON)OFF OFF OFF ON CFM WATTS 1160 220 1150 265 1140 320 1115 345 1100 385 NORMAL ** (400 CFM/TON)OFF OFF OFF OFF CFM WATTS 1355 330 1340 380 1330 425 1320 470 1280 510 HIGH (450 CFM/TON)OFF OFF ON OFF CFM WATTS 1360 330 1360 380 1315 425 1320 470 1280 510 NOTES: 1. * First letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting *DD2B080A9V3VA FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE S4-3 S4-4 0.1 0.3 0.5 0.7 0.9 HEATING 1ST STAGE LOW ON ON CFM TEMP. RISE WATTS 775 50 85 750 51 110 700 55 140 685 56 170 680 57 185 MEDIUM **ON OFF CFM TEMP. RISE WATTS 865 45 110 840 46 140 820 47 175 795 48 210 770 50 235 HIGH OFF OFF CFM TEMP. RISE WATTS 1010 38 160 980 39 190 970 40 230 940 41 260 915 42 285 HEATING 2ND STAGE LOW ON ON CFM TEMP. RISE WATTS 1080 55 180 1060 56 220 1035 57 255 1010 59 285 995 60 325 MEDIUM **ON OFF CFM TEMP. RISE WATTS 1190 50 245 1190 50 290 1170 51 330 1155 51 370 1140 52 410 HIGH OFF OFF CFM TEMP. RISE WATTS 1345 44 330 1335 44 380 1320 45 425 1310 45 475 1275 46 505 INDOOR BLOWER TIMING Heating: The ECM Fan Control controls the variable speed indoor blower. The blower "on" time is fixed at 45 seconds after ignition. The FAN-OFF period is field selectable by dip switches #2 and #3 on the Integrated Furnace Control at 60, 100, 140, or 180 seconds. The factory setting is 100 seconds, (See unit wiring diagram). Cooling: The fan delay-off period is set by dip switches on the ECM Fan Control board connected to the Integrated Furnace Control. The options for cooling delay off is field selectable by dip switches #5 and #6. However, dip switch #1 on the Inte- grated Furnace Control must be set to "ON" for cooling mode to function properly. The following table and graph explain the delay-off settings: ** - This selection provides a ramping up and ramping down of the blower speed to provide improved comfort, quietness, and potential energy savings. The graph below shows the ramping process. COOLING OFF - DELAY OPTIONS SWITCH SETTINGS SELECTION NOMINAL- AIRFLOW 5 - OFF 6 - OFF NONE SAME 5 - ON 6 - OFF 1.5 MINUTES 100% * 5 - OFF 6 - ON 3 MINUTES 50% 5 - ON 6 - ON **50 - 100% * - This setting is equivalent to BAY24X045 relay benefit ** - This selection provides ENHANCED MODE, which is a ramping up and ramping down of the blower speed to pro- vide improved comfort, quietness, and potential energy sav- ings. See Wiring Diagram notes on the unit or in the Service Facts for complete wiring setup for ENHANCED MODE. The graph which follows, shows the ramping process. OFF 50%50% 80% Dehumidify EfficiencyFast Coil Cooling 1 minute 3 minutes 7.5 minutes 100% if necessary OFF TYPE RATINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 Temp. rise (Min.-Max.) °F. BLOWER DRIVE Diameter-Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts/Ph/Hz FLA COMBUSTION FAN - Type Drive - No. Speeds Motor HP PSC [Shaded Pole] - RPM Volts / Ph / Hz FLA PSC [Shaded pole] FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) Shipped 1 Central Furnace heating designs are certified by the American Gas Association Inc. Laboratories. 2 Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% for each 1000 feet above sea level. 3 Based on U.S. Government Standard Tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. VENT COLLAR — Size (in.) HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES — Main Nat.Gas. Qty. — Drill Size L.P. Gas Qty. — Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS — Type Number POWER CONN. — V/Ph/Hz 4 Ampacity (In Amps) Max. Overcurrent Protection (amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) Uncrated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) General Data 1 Downflow / Horizontal 52,000 41,600 80,000 63,000 35 - 65 DIRECT 10 x 7 1 VARIABLE SPEED See Fan Performance 1/2 VARIABLE 115/1/60 7.7 Centrifugal Direct - 2 1/100 / [1/145] - 2543/1727 115/1/60 0.70/0.40 / [0.23/0.20] Yes High Velocity 2 - 14 x 20 - 1in. 4 Round Alum. Steel 20 3 — 45 3 — 56 Redundant - Two Stage Hot Surface Ignition Multiport Inshot 3 115/1/60 10.5 15 1/2 H x W x D 41- 3/4 x 19-1/2 x 30-1/2 40 x 17-1/2 x 28-1/2 146 / 135 Library Product Section Product Model Literature Type Sequence Date File No. Supersedes Since Ingersoll Rand has a policy of continuous product and product data improvement, it reserves the right to change specifications and design without notice. Ingersoll Rand 6200 Troup Highway Tyler, TX 75707 Technical Literature - Printed in U.S.A. NATURAL GAS MODELS — Central heating furnace designs are certified by the Ameri- can Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION — The Integrated Sys- tem Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety. QUICK HEATING— Durable, cycle tested, heavy gauge aluminized steel heat ex- changer quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase ef- ficiency and provide discharge of gas fumes to the outside, allows common venting with hot water heater. Mechanical Specifications BURNERS — Multi-port, in-shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners. INTEGRATED SYSTEM CONTROL— Exclu- sively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. AIR DELIVERY — The variable speed, direct- drive blower motor, with sufficient airflow range for most heating and cooling require- ments, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. (Fan relay and 35VA control transformer is standard). STYLING — Heavy gauge steel and "wrap- around" cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil-faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. FEATURES AND GENERAL OPERATION — These High Efficiency Gas Furnaces employ a Hot Surface Ignition system, which eliminates the waste of a constantly burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter. b. Vent proving differential switch. - Furnaces Furnace TDD2-A9V Submittal - 04/15 TDD2B080A9V-SUB-1B TDD2B080A9V-SUB-1A