8412 176th St Ne_PA25-0074_2025
SPECIFICATIONS General Model No. EL17XC1-018 EL17XC1-024 EL17XC1-030 EL17XC1S036 EL17XC1-041 Data Nominal Tonnage 1.5 2 2.5 3 3.5 Indoor Unit Expansion Valve (TXV) (If needed) 12J18 12J18 12J18 12J19 12J20 Connections Liquid line OD - in. 3/8 3/8 3/8 3/8 3/8 (sweat) Suction line OD - in. 3/4 3/4 3/4 7/8 7/8 Refrigerant 1 R-410A charge furnished 4 lbs. 8 oz. 5 lbs. 2 oz. 6 lbs. 8 oz. 8 lbs. 8 oz. 8 lbs. 12 oz. Outdoor Net face area - sq. ft. Outer coil 16.33 21.00 16.33 21.00 22.17 Coil Inner coil - - - - - - 15.75 20.25 21.33 Tube diameter - in. 5/16 5/16 5/16 5/16 5/16 No. of rows 1 1 2 2 2 Fins per inch 26 26 22 22 22 Outdoor Diameter - in. 22 22 22 22 26 Fan No. of blades 2 3 3 3 3 Motor hp 1/6 1/8 1/8 1/6 1/3 Cfm 2610 2990 2820 3040 3920 Rpm 825 825 825 825 825 Watts 160 160 160 190 180 Shipping Data - lbs. 1 pkg. 185 205 210 235 260 ELECTRICAL DATA Line voltage data - 60Hz 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph 2 Maximum overcurrent protection (MOCP) amps 15 20 25 30 35 3 Minimum circuit ampacity (MCA) 12 15.4 18.4 17.4 21.9 Compressor Rated load amps 8.8 11.7 14.1 13.1 15.4 Locked rotor amps 42.6 59.5 71.3 83.1 92.1 Outdoor Fan Full load amps 1 0.74 0.74 1 2.6 Motor Locked rotor amps 1.9 1.65 1.65 1.9 3.2 CONTROLS - ORDER SEPARATELY E30 Smart Wi-Fi Thermostat 20A65 • • • • • Remote Outdoor Temperature Sensor X2658 • • • • • OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 • • • • Compressor Hard Copeland 10J42 • • • Start Kit LG 88M91 • • • • • 45F08 • • • • • 47J27 • • • • • Freezestat 3/8 in. tubing 93G35 • • • • • 5/8 in. tubing 50A93 • • • • • 58M81 • • • • • 4 Low Ambient Kit (Fan Cycling) 34M72 • • • • • Refrigerant 3/8 x 3/4 x 3/8 - 20 ft. 89J56 Line Sets 3/8 x 3/4 x 3/8 - 30 ft. 89J57 • • • (Liq. x 3/8 x 3/4 x 3/8 - 40 ft. 89J58 Suc. OD x 3/8 x 3/4 x 3/8 - 50 ft. 89J59 Insulation 3/8 x 7/8 x 3/8 - 30 ft. 89J60 Thickness - 3/8 x 7/8 x 3/8 - 40 ft. 89J61 • • Length) 3/8 x 7/8 x 3/8 - 50 ft. 89J62 NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. 1 additional refrigerant charge required. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit. EL17XC1 - 1.5 to 5 Ton Air Conditioner / Page 7 !" #$%&$"'() **+,- . / 0("$!") 12( 0("$!" !" 3 4!'5"'() 6789:;7 <:= >?@A:;7 :AB CA=D:99 E FGE DHA :G; IJ K 12( L$M ) NOPQRSQTU VUU WM LX) YZ+Z[\ZY]^ _M$'% `// 44) aPUbcdUSefghiQjkblh 0 %% LX) m$'%'(n `// 44) ]Y*Z *-,SO oS pU 0'"q) rPjQTgSlT s"$" ) ti u'5) []ZZ^ K 0("$!" L$M ) vPUTTiT wUiSQTg 1..'! LX) Z\,ZY]-[\\ _M$'% `// 44) xiQhQUfdPUTTiTOUiSQTgkblh 0 %% LX) m$'%'(n `// 44) Y,\* o *^YSO yj 0'"q) z{c|Qji s"$" ) tr u'5) []*,] }~ 0("$!" }'! (4 L&M€ ) v‚ppwr[-*Â[ _ƒ5'$"'( 3$" ) *Z„Z[„Z\Z+ 54 / '5'(n m$" '$%) 0ss †$44 †%$!‡ s" % ˆ$%‰$('Š / s" % 1"‹ 54 / '5'(n s'Š ) ŒŽ ‘ !"# $%"&'( )*&$")&'+ ,("%!-"''. &!! !! #&.&! / 0/ + ,1$"%0&$#"$!+ )%"2$/ 3+'&$, 4" - + ,5&.' 678(&9. , :1", #/2,) ,%&"$+ ,("%!; <= > ?@ AA B CD E F A@ GH II J F A@ KII F A@ KLII M A N = GII K K GLI K@L GLI KII OL KLII LO I F MA O<P F MA O<PP < N EQRA E N H AS TD DF T> U = = P V D =A M GH II J =A M KII W F < W = A F A N GH II W = A F A N KII W = A F A N KLII W B NGH L W B N AA KL M T> N M BOF A N ! "##$%"##& '$ ( ) ' ! "##&$ ' %"##&$ ' %*##&$ ' ' ' ! "##&$ %"##&$ + + &, - . ( ) ( ) /0121345126784609660193:;17<8:2=967:<7>5:221569<?60966015:<>62@567:<:<A9<?601:55@B9<549<?601@>1 :860193:;1?1>52731?B2:B1264C7DD317<955:2?9<51C760601D9C>A2@D1>9<?21E@D967:<:8601F6961:8 G9>07<E6:<H IJKLMNOPQRSTUVVWVXUWYZV[ \OMQR]]^_`^_a_` SPECIFICATIONS Gas Model No. EL280DF070E36A EL280DF090E48B Heating Performance 1 AFUE 80% 80% High Input - Btuh 66,000 88,000 Fire Output - Btuh 52,000 69,000 Temperature rise range - °F 30 - 60 35 - 65 Gas Manifold Pressure (in. w.g.) 3.5 / 10.0 3.5 / 10.0 Nat. Gas / LPG/Propane Low Input - Btuh 43,000 57,000 Fire Output - Btuh 35,000 46,000 Temperature rise range - °F 20 - 50 20 - 50 Gas Manifold Pressure (in. w.g.) 1.7 / 4.5 1.7 / 4.5 Nat. Gas / LPG/Propane High static - in. w.g. Heating 0.5 0.5 Cooling 0.5 0.5 Connections Flue connection - in. round 4 4 in. Gas pipe size IPS 1/2 1/2 Indoor Wheel nominal diameter x width - in. 10 x 8 10 x 10 Blower Motor output - hp 1/2 3/4 Tons of add-on cooling 1.5 - 3.5 3 - 4 Air Volume Range - cfm 400 - 1475 780 - 1700 Electrical Voltage 120 volts - 60 hertz - 1 phase Data Blower motor full load amps 6.1 8.2 Maximum overcurrent protection 15 15 Shipping Data lbs. - 1 package 123 142 NOTE - Filters and provisions for mounting are not furnished and must be field provided. 1 Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. OPTIONAL ACCESSORIES - ORDER SEPARATELY “A†Width “B†Width Models Models CABINET Downflow Combustible Flooring Base 11M59 11M60 CONTROLS E30 Smart Wi-Fi Thermostat 20A65 20A65 Remote Outdoor Temperature Sensor X2658 X2658 Furnace Twinning Panel Y3653 Y3653 Furnace Twinning Kit 16W72 16W72 Transformer (75VA) 27J32 27J32 DOWNFLOW FILTER KITS Downflow Filter Kit 51W06 51W07 No. and Size of filter - in. (1) 20 x 20 x 1 (2) 20 x 16 x 1 EL280DFE / Page 8 City of Arlington 18204 59th Avenue NE, Arlington, Washington 98223 Phone: 360-403-3551 Invoice Number: 25-0070 INVOICE Invoice Date: November 25, 2025 Account Number: 284723462 Bill To: Invoice Questions? Phone: 360-403-3551 Brennan Heating 4601 S 134th Pl Email: ced@arlingtonwa.gov Invoice Due Date: November 25, 2025 Record Number: Permit A25-0074 Parcel Number: 00958500002900 Location: 8412 176TH ST NE Date Description Paid Date Amount Paid Balance November 25, Mechanical Base Fee (006.322.10.00.01) $25.00 2025 November 25, Processing/Technology (320.341.43.00.02) $25.00 2025 November 25, Inspection (006.322.10.00.01) $75.00 2025 November 25, Air Cond. Unit > 100 BTU/h $15.00 2025 November 25, Forced Air Heat (006.322.10.00.01) $15.00 2025 TOTAL: Permit Fees $155.00 $155.00 ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- --------------------------------------------------------- REMITTANCE INFORMATION If you are paying by check, please include this portion with your payment and remit to the address listed on this invoice. Remittance Information Invoice Account Total Due Your payment is due by November 25, 2025 Number Number This Invoice 25-0070 284723462 $155.00 Brennan Heating 4601 S 134th Pl City of Arlington 18204 59th Avenue NE, Arlington, Washington 98223 Phone: 360-403-3551 Building Permit Permit #: 25-0074 PERMIT EXPIRES 180 DAYS Parcel: 00958500002900 AFTER DATE OF ISSUANCE. Description of Work: Valuation: 11567.00 Date Applied: December 3, 2025 Permit Address: 8412 176TH ST NE OWNER APPLICANT CONTRACTOR Brennan Heating Christine Lee Brennan Heating 132 MONTVU DR OMAK, WA, 98841 4601 S 134th Pl 2062487900 jaimie@brennanheating.com freckbetz@gmail.com jaimie@brennanheating.com registration_number : Permit Type : Residential - Mechanical Code Year : code_year Stories: Const Type : IRC Building Type VB Dwelling Units : Occupancy Group : R-3 Residential PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. It is unlawful to use or occupy a building or structure until a final inspection has been made and approval or a Certificate of Occupancy has been granted. This permit authorizes only the work noted and covers work to be done on private property only. Any construction on public domain (curbs, sidewalks, driveways, marquees, etc.) will require a separate permit. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. CONDITIONS 1.) Adhere to approved appliances 2.) Permit shall be onsite for inspections. 3.) Call for final inspection INSPECTIONS Inspection Line: 360-403-3417 Call for inspections by 3:30 pm for next day inspection. Please allow 48 hours for Fire Inspections. Please provide the following information when leaving a message: Permit Number, Type of Inspection, and provide preference of morning or afternoon inspection. Inspection Portal: Please login to customer portal and submit for the desired inspection type for the permit. Kevin Olander Building Official ASSOCIATED FEES Date Description Paid Date Amount Paid Balance November 25, Mechanical Base Fee (006.322.10.00.01) $25.00 2025 November 25, Processing/Technology (320.341.43.00.02) $25.00 2025 November 25, Inspection (006.322.10.00.01) $75.00 2025 November 25, Air Cond. Unit > 100 BTU/h (006.322.10.00.01) $15.00 2025 November 25, Forced Air Heat (006.322.10.00.01) $15.00 2025 TOTAL: Permit Fees $155.00 $155.00 Credit/Debit Card 70 Payment Successful November 26, 2025 $155.00 $0.00 Permit Information General Information Permit # 25-0074 Parcel # 00958500002900 Building ID Location 8412 176TH ST NE Permit Type Residential Permit Use Mechanical Zone Permit # Subdivision Applicant Name Brennan Heating Address 4601 S 134th Pl Applicant Email jaimie@brennanheating.c Phone 2062487900 Cell om Owner Name Christine Lee Address 132 MONTVU DR OMAK, WA, 98841 Owner Email freckbetz@gmail.com Phone Cell Contractor Brennan Heating Address Contractor Email jaimie@brennanheating.c Phone Cell om Property Information Type/Improveme Minor Improvement Accessory/Struct IBC Building Type V-B nt ure Current Use R-3 Residential Proposed Use Current Zoning 2 Proposed Zoning Project Cost 11567.00 Project Value 11567.00 Current Use And Proposed Changes Lot Width Lot Depth Map Number Total Area of Building & Accessory Total Area of All Man-made Improvements Structures (Sq Ft) (Sq Ft) General Notes Restrictions / Variances © Community Development Online Portal Page 1 of 6 December 30, 2025 01:02PM Structure Information Structure Type IRC Building Type VB # of Stories Usable Floor Area (Sq Ft) Structure Height # of Units Load per Floor (Lbs) Sign Dimensions # of Bedrooms # of Bathrooms Occupancy With Chairs Tables & Chairs Empty Room Foundation Foundation Type Footing Depth Material Foundation Information Setbacks Front & 0 0 Setbacks Right & 0 0 Rear Left Sides Setbacks Information Water Utility Public Sewage Utility Public Gas Utility Public Electric Utility Public Driveway Width # of Off Street # of Off Street Parking Loading Miscellaneous Information © Community Development Online Portal Page 2 of 6 December 30, 2025 01:02PM Contractors License # Business Name Type Contact BRENNHA971R9 Brennan Heating General Contractor Jaimie Howe © Community Development Online Portal Page 3 of 6 December 30, 2025 01:02PM Inspections Inspection # Inspection Type Status Date Inspector 25-0048 Residential - Mechanical Pass December 15, 2025 Kevin Olander Final © Community Development Online Portal Page 4 of 6 December 30, 2025 01:02PM Contacts Contact Name Type Project Address Phone Brennan Heating Applicant 4601 S 134th Pl 206-248-7900 Brennan Heating Contractor 4601 S 134th Pl, Tukwila, WA 98168 Christine Lee Owner 132 MONTVU DR OMAK, WA, 98841 Brennan Heating Others 4601 S 134th Pl 206-248-7900 © Community Development Online Portal Page 5 of 6 December 30, 2025 01:02PM Fees Fee Type Date Debit Credit Balance Permit Fees November 25, 2025 $155.00 $155.00 $155.00 $0.00 T O T A L $155.00 $155.00 $0.00 © Community Development Online Portal Page 6 of 6 December 30, 2025 01:02PM Powered by TCPDF (www.tcpdf.org)