Loading...
HomeMy WebLinkAbout3529 172nd St Ne_BLD6632_2025 BCH0060LCACZC0227 - SUBMITTAL Project Name: - Project Location: - Quote ID: - Item #: 1000 Submitted For: - Submitted On: - Submitted By: - Submitted From: - Identity #: - Tag: - For Record For Approval By:_____________________________________________ Date:_______________________ General Product Information Product Family: HTS Compressor Brand: Copeland Application: Outdoor Compressor Type: Scroll Temperature Range: Low Temp Compressor Hp: 6 Voltage: (Volts/Ph/Hz) 208-230/3/60 Compressor Model: ZF18K4E-TF5-251 Refrigerant Type: R448A Number of Compressor(s): 1 Piping: Standard Coil Type: Microchannel Technical Information Performance Data Ambient Saturated Suction Application Capacity* Altitude AWEF Value Temperature (°F) Temperature (°F) (BTU/H) (ft) 95 -10 24,330 0 3.15 Electrical Data Compressor(s) Fan Motor(s) Electric Ratings RLA LRA Quantity Hp FLA Defrost High or Number of MCA MOPD Evap.Fan Defrost Type Low Amps? Contactors Amps Heater Amps 21.5 156 1 1/3 3.5 AIR DEFROST - - 30.3 50 - - Unit Specifications Connections (in.) Receiver 90% Full (lbs) Fan Blade(s) Approx. Net Sound Data Diameter Weight Liquid Line Suction Standard Over Sized (in) (dB) (lbs) 0.5 0.875 20 40 22 64 342 Dimensional Drawing(s) Page 1 of 2 BCH0060LCACZC0227 - SUBMITTAL Project Name: - Project Location: - Quote ID: - Item #: 1000 Submitted For: - Submitted On: - Submitted By: - Submitted From: - Identity #: - Tag: - Standard Features CABINET AND CONSTRUCTION SERVICEABILITY • MICROCHANNEL COIL TECHNOLOGY STANDARD ON ALL UNITS • SUCTION SERVICE VALVES FOR HERMETIC AND SCROLL COMPRESSORS • PAINTED STEEL CABINETS FOR SUPERIOR STRENGTH AND CORROSION LOCATED OUTSIDE THE CABINET FOR QUICK INSTALLATIONS. PROTECTION • RECEIVER WITH FUSIBLE PLUG, LIQUID SHUTOFF VALVE AND CHARGING PORT IS • HEAVY DUTY, STEEL, 1-1/2” TALL BASE STANDARD • LARGE ELECTRICAL PANEL FOR EASE OF ACCESS • PREFABRICATED WIRING HARNESSES FOR TIGHT CRIMP CONNECTIONS AND CONSISTENT LABELING • UNIT STAYS ON IF THE HOOD IS REMOVED FOR SERVICING • SIGHT GLASS IS EASILY VIEWABLE QUALITY • ALL UNITS ARE COMPLETELY LEAK TESTED IN A HELIUM ENVIRONMENT, BUMP TESTED AND ALLOWED TO CYCLE OFF ON THE HIGH AND LOW PRESSURE CONTROL. EACH UNIT HAS A COPY OF THE RUN DATA SHIPPED INSIDE THE ELECTRICAL PANEL • ELECTRICAL CIRCUITS ARE COMPLETELY CHECKED FOR CONTINUITY • PIPING IS LAID OUT TO MINIMIZE STRESS AND VIBRATION AND IS PRE-BENT TO ELIMINATE LEAKS • ENCAPSULATED, AUTO-RESET, HIGH AND LOW PRESSURE CONTROLS TO ELIMINATE LEAKS (ADJUSTABLE LOW PRESSURE CONTROL STANDARD) Options Mounted Options • BRAND LABEL OPTION - BOHN • Defrost Timer Options - INTELLIGEN • Pressure Options - ADJUSTABLE LOW - FIXED HIGH • Motor - PSC • Crankcase Heater - CRANKCASE HEATER • Phase Loss Monitor - NONE • Fused Disconnect - NO FUSED DISCONNECT • Cabinet Selection - Painted • Coil Selection - MICROCHANNEL COIL • Receiver Options - STANDARD W/ LOW AMBIENT KIT (H • Liquid Line Options - FILTER DRIER AND SIGHT GLASS • Suction Line Options - FILTER AND ACCUMULATOR • Discharge Line Options - HEAD PRESSURE VALVE 100# • PRE-CHARGE OPTIONS - None • BASE LEG BRACKET OPTIONS - None • HAIL GUARD - None • COMPLIANCE - DOE COMPLIANT • SPECIAL SELECTION - MCDONALD'S LABELS Minimum Unit Clearances Notes * Capacities shown are Application Capacities reflecting nominal operation at 10°F TD. For models within the scope of the DOE AWEF (Annual Walk-in Energy Factor) standard, the Net Capacity is determined by the AHRI 1250 test method. DOE will publish this compliance data at www.regulations.doe.gov *Only refrigerants in compliance with New York state regulations can be used in the state of New York. Page 2 of 2 BEL0205BS6EEAD0096 - SUBMITTAL Project Name: - Project Location: - Quote ID: - Item #: 1000 Submitted For: - Submitted On: - Submitted By: - Submitted From: - Identity #: - Tag: - For Record For Approval By:_____________________________________________ Date:_______________________ General Product Information Product Family: BEL Motor type EC Defrost Type: Electric Number of Fans: 4 Voltage: (Volts/Ph/Hz) 208-230/1/60 Fan HorsePower 1/20 Refrigerant Type: R448A Fins per Inch 6 Technical Information Performance Data Capacity Air Flow Altitude AWEF Value TD SST Application Capacity* Fan Diameter Air Throw (ft) (ft) CFM (°F) (°F) (BTU/H) (in.) Standard w/Collar Cooler > 32 Freezer <= 32 10 -20 20,100 2562 12 - - 0 N/A 4.14 Electrical Data Fan Motor(s) Defrost Heater(s) Drain pan Heater(s) HG Watts Amps Watts Amps Watts Amps 236 2 4200 18.3 - - Unit Specifications Connections (in.) Approx. Net Weight Coil Inlet Suction External Equalizer Drain Side Port Hot Gas Drain Pan (lbs) 1/2 1-1/8 1/4 3/4 - - 100 Dimensional Drawing(s) Page 1 of 2 BEL0205BS6EEAD0096 - SUBMITTAL Project Name: - Project Location: - Quote ID: - Item #: 1000 Submitted For: - Submitted On: - Submitted By: - Submitted From: - Identity #: - Tag: - Standard Features EASE OF INSTALLATION SERVICE PERFORMANCE • ALL ELECTRICAL COMPONENTS FACTORY WIRED TO TERMINAL BOARD AND • INTERNAL PANELS ARE ISOLATED FOR QUIET OPERATION IDENTIFIED, MAKING IT EASY TO FIELD WIRE THE UNIT • INTERNALLY ENHANCED TUBING AND FIN DESIGN FOR HIGHER EFFICIENCY • CABINET DESIGN FEATURES HINGED, REMOVABLE FRONT ACCESS PANELS ON • EC MOTORS STANDARD ON ALL MODELS FOR IMPROVED UNIT EFFICIENCY EACH SIDE FOR EASY ACCESS TO ELECTRICAL AND REFRIGERATION COMPONENTS • LIQUID LINE SOLENOID WIRE HARNESS IS FACTORY-INSTALLED FOR QUICK INSTALLATION • MOTORS PLUG INTO WIRING HARNESS FOR EASIER SERVICING • HINGED, REMOVABLE DRAIN PAN FOR EASY AND SAFE ACCESS • PRE-DRILLED HOLES ON THE BACK OF THE UNIT FOR ROOM THERMOSTAT • QUICK REMOVAL FAN GUARD/MOTOR ASSEMBLY FOR EASY SERVICE OR REPLACEMENT OF AIR MOVER PARTS RELIABLE DURABLE VERSATILE • HEAVY GAUGE GRAINED ALUMINUM CABINET CLEANS EASILY AND LOOKS • LARGE DIAMETER DRAIN HOLE (3/4 " ID) IS LOCATED TOWARDS THE BACK OF THE ATTRACTIVE UNIT • MOLDED FAN GUARD AND ACCESS PANELS ARE MADE OF STRONG, DURABLE, • MINIMAL HEIGHT OF THE LOW PROFILE SERIES MAKES IT IDEAL FOR LOW CEILING AND NSF AND UL SANITATION RATED PLASTIC MATERIAL COOLERS • SWEAT CONNECTIONS TO REDUCE POTENTIAL FOR LEAKS Options Mounted Options • Cabinet Type - Stucco • Coil Mechanical Option - Intelligen • Controller Option - Intelligen • Drain Pan Defrost Type - Electric • Drain Pan Type - Stucco • DTFD Option - None • Fan Blade - Standard • Fan Guard - Molded • Coil Fin Material - Aluminium • Hot Gas External Piping - None • INTELLIGEN WEBSERVER CARD - YES • UC Solenoid Voltage - None • Valve Part Number - E2V24 • Nozzle PartNumber - L-2-1/2 Minimum Unit Clearances Notes * Capacities shown are Application Capacities reflecting nominal operation at 10°F TD. For models within the scope of the DOE AWEF (Annual Walk-in Energy Factor) standard, the Net Capacity is determined by the AHRI 1250 test method. DOE will publish this compliance data at www.regulations.doe.gov Page 2 of 2 BCH0015MBACZC0227 - SUBMITTAL Project Name: - Project Location: - Quote ID: - Item #: 1000 Submitted For: - Submitted On: - Submitted By: - Submitted From: - Identity #: - Tag: - For Record For Approval By:_____________________________________________ Date:_______________________ General Product Information Product Family: HTS Compressor Brand: Copeland Application: Outdoor Compressor Type: Scroll Temperature Range: Medium Temp Compressor Hp: 1.5 Voltage: (Volts/Ph/Hz) 208-230/1/60 Compressor Model: ZS13KAE-PFV-118 Refrigerant Type: R448A Number of Compressor(s): 1 Piping: Standard Coil Type: Microchannel Technical Information Performance Data Ambient Saturated Suction Application Capacity* Altitude AWEF Value Temperature (°F) Temperature (°F) (BTU/H) (ft) 95 25 13,890 0 7.6 Electrical Data Compressor(s) Fan Motor(s) Electric Ratings RLA LRA Quantity Hp FLA Defrost High or Number of MCA MOPD Evap.Fan Defrost Type Low Amps? Contactors Amps Heater Amps 10.8 56 2 1/15 1 AIR DEFROST - - 15 25 - - Unit Specifications Connections (in.) Receiver 90% Full (lbs) Fan Blade(s) Approx. Net Sound Data Diameter Weight Liquid Line Suction Standard Over Sized (in) (dB) (lbs) 0.5 0.875 14 20 14 63 230 Dimensional Drawing(s) Page 1 of 2 BCH0015MBACZC0227 - SUBMITTAL Project Name: - Project Location: - Quote ID: - Item #: 1000 Submitted For: - Submitted On: - Submitted By: - Submitted From: - Identity #: - Tag: - Standard Features CABINET AND CONSTRUCTION SERVICEABILITY • MICROCHANNEL COIL TECHNOLOGY STANDARD ON ALL UNITS • SUCTION SERVICE VALVES FOR HERMETIC AND SCROLL COMPRESSORS • PAINTED STEEL CABINETS FOR SUPERIOR STRENGTH AND CORROSION LOCATED OUTSIDE THE CABINET FOR QUICK INSTALLATIONS. PROTECTION • RECEIVER WITH FUSIBLE PLUG, LIQUID SHUTOFF VALVE AND CHARGING PORT IS • HEAVY DUTY, STEEL, 1-1/2” TALL BASE STANDARD • LARGE ELECTRICAL PANEL FOR EASE OF ACCESS • PREFABRICATED WIRING HARNESSES FOR TIGHT CRIMP CONNECTIONS AND CONSISTENT LABELING • UNIT STAYS ON IF THE HOOD IS REMOVED FOR SERVICING • SIGHT GLASS IS EASILY VIEWABLE QUALITY • ALL UNITS ARE COMPLETELY LEAK TESTED IN A HELIUM ENVIRONMENT, BUMP TESTED AND ALLOWED TO CYCLE OFF ON THE HIGH AND LOW PRESSURE CONTROL. EACH UNIT HAS A COPY OF THE RUN DATA SHIPPED INSIDE THE ELECTRICAL PANEL • ELECTRICAL CIRCUITS ARE COMPLETELY CHECKED FOR CONTINUITY • PIPING IS LAID OUT TO MINIMIZE STRESS AND VIBRATION AND IS PRE-BENT TO ELIMINATE LEAKS • ENCAPSULATED, AUTO-RESET, HIGH AND LOW PRESSURE CONTROLS TO ELIMINATE LEAKS (ADJUSTABLE LOW PRESSURE CONTROL STANDARD) Options Mounted Options • BRAND LABEL OPTION - BOHN • Defrost Timer Options - INTELLIGEN • Pressure Options - ADJUSTABLE LOW - FIXED HIGH • Motor - PSC • Crankcase Heater - CRANKCASE HEATER • Phase Loss Monitor - NONE • Fused Disconnect - NO FUSED DISCONNECT • Cabinet Selection - Painted • Coil Selection - MICROCHANNEL COIL • Receiver Options - STANDARD W/ LOW AMBIENT KIT (H • Liquid Line Options - FILTER DRIER AND SIGHT GLASS • Suction Line Options - FILTER AND ACCUMULATOR • Discharge Line Options - HEAD PRESSURE VALVE 150# • PRE-CHARGE OPTIONS - None • BASE LEG BRACKET OPTIONS - None • HAIL GUARD - None • COMPLIANCE - DOE COMPLIANT Minimum Unit Clearances Notes * Capacities shown are Application Capacities reflecting nominal operation at 10°F TD. For models within the scope of the DOE AWEF (Annual Walk-in Energy Factor) standard, the Net Capacity is determined by the AHRI 1250 test method. DOE will publish this compliance data at www.regulations.doe.gov *Only refrigerants in compliance with New York state regulations can be used in the state of New York. Page 2 of 2 BEL0125BS6AMAD0096 - SUBMITTAL Project Name: - Project Location: - Quote ID: - Item #: 1000 Submitted For: - Submitted On: - Submitted By: - Submitted From: - Identity #: - Tag: - For Record For Approval By:_____________________________________________ Date:_______________________ General Product Information Product Family: BEL Motor type 2 SPEED EC Defrost Type: Air Number of Fans: 2 Voltage: (Volts/Ph/Hz) 208-230/1/60 Fan HorsePower 1/20 Refrigerant Type: R448A Fins per Inch 6 Technical Information Performance Data Capacity Air Flow Altitude AWEF Value TD SST Application Capacity* Fan Diameter Air Throw (ft) (ft) CFM (°F) (°F) (BTU/H) (in.) Standard w/Collar Cooler > 32 Freezer <= 32 10 25 15,500 1220 12 - - 0 9 N/A Electrical Data Fan Motor(s) Defrost Heater(s) Drain pan Heater(s) HG Watts Amps Watts Amps Watts Amps 110 1 - - - - Unit Specifications Connections (in.) Approx. Net Weight Coil Inlet Suction External Equalizer Drain Side Port Hot Gas Drain Pan (lbs) 1/2 7/8 1/4 3/4 - - 56 Dimensional Drawing(s) Page 1 of 2 BEL0125BS6AMAD0096 - SUBMITTAL Project Name: - Project Location: - Quote ID: - Item #: 1000 Submitted For: - Submitted On: - Submitted By: - Submitted From: - Identity #: - Tag: - Standard Features EASE OF INSTALLATION SERVICE PERFORMANCE • ALL ELECTRICAL COMPONENTS FACTORY WIRED TO TERMINAL BOARD AND • INTERNAL PANELS ARE ISOLATED FOR QUIET OPERATION IDENTIFIED, MAKING IT EASY TO FIELD WIRE THE UNIT • INTERNALLY ENHANCED TUBING AND FIN DESIGN FOR HIGHER EFFICIENCY • CABINET DESIGN FEATURES HINGED, REMOVABLE FRONT ACCESS PANELS ON • EC MOTORS STANDARD ON ALL MODELS FOR IMPROVED UNIT EFFICIENCY EACH SIDE FOR EASY ACCESS TO ELECTRICAL AND REFRIGERATION COMPONENTS • LIQUID LINE SOLENOID WIRE HARNESS IS FACTORY-INSTALLED FOR QUICK INSTALLATION • MOTORS PLUG INTO WIRING HARNESS FOR EASIER SERVICING • HINGED, REMOVABLE DRAIN PAN FOR EASY AND SAFE ACCESS • PRE-DRILLED HOLES ON THE BACK OF THE UNIT FOR ROOM THERMOSTAT • QUICK REMOVAL FAN GUARD/MOTOR ASSEMBLY FOR EASY SERVICE OR REPLACEMENT OF AIR MOVER PARTS RELIABLE DURABLE VERSATILE • HEAVY GAUGE GRAINED ALUMINUM CABINET CLEANS EASILY AND LOOKS • LARGE DIAMETER DRAIN HOLE (3/4 " ID) IS LOCATED TOWARDS THE BACK OF THE ATTRACTIVE UNIT • MOLDED FAN GUARD AND ACCESS PANELS ARE MADE OF STRONG, DURABLE, • MINIMAL HEIGHT OF THE LOW PROFILE SERIES MAKES IT IDEAL FOR LOW CEILING AND NSF AND UL SANITATION RATED PLASTIC MATERIAL COOLERS • SWEAT CONNECTIONS TO REDUCE POTENTIAL FOR LEAKS Options Mounted Options • Cabinet Type - Stucco • Coil Mechanical Option - Intelligen • Controller Option - Intelligen • Drain Pan Defrost Type - None • Drain Pan Type - Stucco • DTFD Option - None • Fan Blade - Standard • Fan Guard - Molded • Coil Fin Material - Aluminium • Hot Gas External Piping - None • INTELLIGEN WEBSERVER CARD - YES • UC Solenoid Voltage - None • Valve Part Number - E2V11 • Nozzle PartNumber - L-3/4 Minimum Unit Clearances Notes * Capacities shown are Application Capacities reflecting nominal operation at 10°F TD. For models within the scope of the DOE AWEF (Annual Walk-in Energy Factor) standard, the Net Capacity is determined by the AHRI 1250 test method. DOE will publish this compliance data at www.regulations.doe.gov Page 2 of 2 Permit #: 6632 Permit Date: 07/17/25 Permit Type: COMMERCIAL MECHANICAL Project Name: McDonald's Applicant Name: Northsound Refrigeration Applicant Address: 6188 Portal Way Applicant, City, State, Ferndale, WA 98248 Zip: Contact: Matthew Deering Phone: 360-380-1381 / 360-815-9580 Email: mattd@northsoundrefrigeration.com Scope of Work: Replace walk-in cooler equipment both cooler and freezer (Emergency replacement) Valuation: 18500.00 Square Feet: 0 Number of Stories: 4467 Construction Type: VB Occupancy Group: A-2; Assembly ID Code: Permit Issued: 07/22/2025 Permit Expires: 01/19/2026 Form Permit Type: COMMERCIAL MECHANICAL Status: COMPLETE Assigned To: Kristin Foster Property Parcel # Address Legal Description Owner Name Owner Phone Zoning MCDONALDS 31052100306100 3529 172ND ST NE REC AF NO 9407075002 600 RESTAURANT CORP Contractors Contractor Primary Contact Phone Address Contractor Type License License # Northsound CONSTRUCTION Matt Deering 360-380-1381 PO Box 29116 L&I NORTHR*754MW Refrigeration CONTRACTOR Northsound CONSTRUCTION Matt Deering 360-380-1381 PO Box 29116 COA 602-170-260 Refrigeration CONTRACTOR Northsound CONSTRUCTION Matt Deering 360-380-1381 PO Box 29116 L&I NORTHRI985PS Refrigeration CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C14. 12/01/2025 MECHANICAL 12/02/2025 12/02/2025 BUILDING Approved FINAL Plan Reviews Date Review Type Description Assigned To Review Status COMMERCIAL 07/17/2025 BUILDING Approved MECHANICAL Fees Fee Description Notes Amount Processing/Technology $25.00 Mechanical Commercial Plan Review Table 4-1 $292.20 Mechanical Misc. Not otherwise specified $50.00 Refrigeration Unit > 100 BTU/h Enter # of units $50.00 Credit Card Service $12.52 Total $429.72 Attached Letters Date Letter Description 07/22/2025 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount XBP Conf: 07/22/2025 $417.20 237880455 07/22/2025 Paul S 237880455 Hannah Hardwick $12.52 Outstanding Balance $0.00 Notes Date Note Created By: 11/26/2025 sent expiration notice Hannah Hardwick Uploaded Files Date File Name 08/14/2025 27823642-20250813_BLD6632_IssuedPermit.pdf 07/17/2025 27391312-20250717_BLD6632 WIF.pdf 07/17/2025 27391313-20250717_BLD6632_WIC Evap.pdf 07/17/2025 27391314-20250717_BLD6632_WIC.pdf 07/17/2025 27391315-20250717_BLD6632 WIF Evap.pdf 07/17/2025 27391311-20250717_BLD6632_App.pdf