HomeMy WebLinkAbout19603 60th Ave Ne_BLD6657_2025 CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 19603 60TH AVE NE Permit #: 6657 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 00746300001400 DATE OF ISSUANCE. Scope of Work: installation of natural gas generator and gas piping Valuation: 53000.00 OWNER APPLICANT CONTRACTOR MINA PROPERTIES II LLC Farmers Electric Design and Construction Farmers Electric D & C 6010 199TH ST NE 2020 Maltby Rd #102 2020 Maltby Rd #102 ARLINGTON, WA 98223 Bothell, Wa, 98021 Bothell, WA 98021 8775906139 425-508-1813 LIC: 602 980 144 EXP: 01/31/2026 LIC: FARMEED904B1 EXP: 01/21/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC #: EXP: LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2021 STORIES: 2 CONST. TYPE: VB DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 10/13/2025 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved plans. Permit shall be onsite for inspection. Call for final inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/23/2025 Mechanical Commercial Plan Review $649.40 10/23/2025 Credit Card Service $19.48 10/23/2025 Processing/Technology $25.00 10/23/2025 Gas Piping/Units $15.00 10/23/2025 Mechanical Base $25.00 10/23/2025 Mechanical Misc. $15.00 10/23/2025 Credit Card Service $2.40 Total Due: $751.28 Total Payment: $751.28 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail C03. FOUNDATION/SLAB Approved SPECIFICATION SHEET QUIET TM CONNECT Series RS40 Shown with Sound Level 1 option Features and benefits Robust product design and testing - The generator is designed to operate under extreme environmental conditions including cold weather starts at as low as -40° F. The generator is tested and certified per the latest EPA, UL and IBC Seismic standards and is capable of meeting NFPA 110 requirements when equipped with the necessary accessories and properly installed. Flexible exercise mode - The innovative, flexible exercise mode enables the generator to exercise at a time, frequency and duration that suits the customer's preference - as little as 2 minutes every 6 months - reducing unnecessary fuel consumption, emissions and noise. Advanced enclosure design - The aesthetically appealing enclosure incorporates special designs that deliver the quietest generator of its kind. Aluminum material plus durable powder coat paint provides the best anti- corrosion performance. The generator set enclosure has been evaluated to withstand 180 mph wind loads in accordance with ASCE 7-10. The intelligent design has removable panels and service doors to provide easy access for service and maintenance. Control system - The PowerCommand® electronic control is standard equipment and provides total generator set system integration including automatic remote starting/stopping, precise frequency and voltage regulation, alarm and status message display, output metering, auto-shutdown at fault detection and NFPA 110 level 1 compliance. Self-diagnostics and easy service - The PowerCommand® electronic control provides industry- leading self- diagnostic capabilities. In addition, critical components of the generator are designed to ensure service and preventive maintenance can be completed in a short period of time. Weight, size, and sound level Weight: 1356 lbs. (615 kg) Size: Length 94 in (2388 mm), width 34 in (864 mm), height 45.5 in (1156 mm) Sound: 68 dB(A) at 23 ft. (7 m) with sound level 1 enclosure Rated amps1 Circuit breaker Series Model Phase Voltage (V) Frequency (Hz) (NG/LPV fuel) (Amps) 1 120/240 60 166.7/166.7 200 3 120/208 60 138.8/138.8 175 RS40 C40 N6 3 120/240 60 120.4/120.4 150 3 277/480 60 60.2/60.2 80 1Derating guidelines: Engine power available up to 114 m (375 ft.) at ambient temperatures up to 40° C (104° F). Above these elevations derate at 4% per 305 m (1000 ft.) and 2% per 10° C above 40° C (104° F). ©2021 Cummins Inc. | NAS-5778-EN (7/21) A052G011 Product features Generator set performance Engine Governor regulation class: ISO 8528 Part 1 Class G2 • Natural gas/propane 1800 rpm engine Voltage regulation, no load to full load: ±1.0% • Engine air cleaner – normal duty Random voltage variation: ±1.0% • Electronic governor, isochronous Frequency regulation: Isochronous • Engine starter, 12 VDC motor Random frequency variation: ± 0.25% @ 60 Hz • Shutdown – low oil pressure Radio frequency emissions compliance: FCC code • Extension – oil drain Title 47 part 15 Class B • Engine oil Fuel system Engine Specifications • Single fuel – natural gas or propane vapor, field Design: Turbo with after cooler selectable Bore: 86.5 mm (3.4 in) Alternator Stroke: 100.0 mm (3.94 in) • 60 Hz, 1 phase, 4 lead, or 3 phase, 12 lead, 120° C Displacement: 2.4 liters (143.5 in3) temperature rise at 40° C ambient Cylinder block: Cast iron, in-line 4 cylinder • Exciter/Voltage regulator – torque match Battery capacity: 550 Amps at ambient temperature of Control 0° F to 32° F (-18° C to 0° C) • PowerCommand 1.1 Battery charging alternator: 50 Amps • Display language – English Starting voltage: 12-Volt, negative ground • Control mounting, right facing Lube oil filter type(s): Spin -on with relief valve Electrical Standard cooling system: 50° C (122° F) ambient • Single circuit breaker, UL certified, right-side mounted cooling system • Battery charging alternator, normal duty Rated speed: 1800 rpm • Battery charger – 6 Amp, regulated Fuel supply pressure Cooling Minimum fuel supply pressure, kPa (in H2O): • Generator set cooling capability – 50° C 1.5 (6.0) • Shutdown – low coolant level Maximum fuel supply pressure, kPa (in H2O): • Engine coolant – 50/50 mixture 3.5 (14.0) • Extension – coolant drain Enclosure Warranty • Aluminum enclosure Sound Level 1 with muffler Base warranty – 2-year standby installed, sandstone color Extended warranties available • Wind rating – 180 mph Code compliance • UL 2200 • EPA emissions, emergency, stationary, 40CFR60 • IBC Seismic • NFPA 110 capable Generator set application • Coolant heater • Crank case vent heater • Large battery rack • Flexible fuel line • Literature (English) – operator’s manual, installation quick guide and manual, service manual Packaging • Shipping pallet, poly bag ©2021 Cummins Inc. | NAS-5778-EN (7/21) A052G011 Typical fuel consumption Fuel consumption – natural gas Fuel consumption – LP vapor Load: 1/4 1/2 3/4 Full Load: 1/4 1/2 3/4 Full ft3/hr: 209.5 304.7 409.5 519.0 ft3/hr: 83.0 121.7 166.0 193.6 m3/hr: 5.9 8.5 11.5 14.5 m3/hr: 2.3 3.4 4.6 5.4 gal/hr 2.3 3.4 4.6 5.4 Conversion factor: 8.58 ft³ = 1 lb. 0.535m³ = 1 kg 36.39 ft³ = 1 gal Easy service and installation Display Removable Service Door Oil Check Oil Fill Natural Gas/Liquid Propane Customer Access Door Circuit Breaker Fuel Connection Air Cleaner Coolant Fill ©2021 Cummins Inc. | NAS-5778-EN (7/21) A052G011 Basic dimensions Note: This outline drawing is provided for general reference only and is not intended for use in design or installation. For more information, see Operators and Installation manuals or contact your dealer for assistance. Automatic transfer panel configurations Typical service entrance ATS model Typical non-service entrance ATS Dedicated emergency standby service installation (100/200A) model installation (100/200A) system (100/200A) ©2021 Cummins Inc. | NAS-5778-EN (7/21) A052G011 Accessories Transfer switch (sold separately) • HMI211RS in-home display, including pre-configured • Automatic Transfer Switches available at various 12-inch harness amperages. (Refer to NAS-5810-EN, A-1568, S- • HMI211 remote display, including pre-configured 1639) 12-inch harness • Service Entrance models are also available, which • HMI220 remote display helps reduce the installation cost. • Auxiliary output relays (2) • All models listed to UL 1008 standard. • Auxiliary configurable signal inputs (8) and relay • Available for both indoor and outdoor applications. outputs (8) • Compatibility with Cummins generator set helps • Annunciator – RS 485 reduce the installation time for the complete • Internet monitoring device – PowerCommand 500 application. • Battery chargers – stand-alone, 12V Warranty policy • Enclosure Sound Level 1 to Sound Level 2 upgrade kit Cummins RS liquid cooled generator set models come with • Enclosure paint touch up kit a 2-year base warranty when used in EPA-Stationary • Base barrier – elevated generator set Emergency application. The RA series Automatic Transfer • Alternator heater Switches come with a 2-year base warranty. Extended • Maintenance and service kit warranty options are available. Please contact your • Engine lift kit Cummins dealer for details. After sale support Largest dealer support network ! Cummins generator sets are supported by the best trained and certified dealer network in the industry. This network of knowledgeable dealers will help you select the right generator for your application and advise you on associated accessories for your generator. Cummins dealers can also help answer any questions you may have regarding ! WARNING: ! WARNING: operation and maintenances requirements of the generators. Certified dealers also offer a complete selection of commonly Standby rating based on: Applicable for Back feed to a utility system can cause supplying emergency power for the electrocution and/or property damage. Do used generator set maintenance parts and manuals. duration of normal power interruption. No not connect to any building electrical except sustained overload capability is available for through an approved device or after building Manuals: Operation and installation manuals ship with the this rating. (Equivalent to fuel stop power in main breaker is open. accordance with ISO3046, AS2789, DIN6271 generator set. To obtain additional copies or other manuals and BS5514) nominally rated. See T030. for this model, see your dealer. To easily locate the nearest certified dealer for Cummins generators in your area, or for more information, contact us at 1-800-344-0039 or visit power.cummins.com. Contact your dealer for more information. Cummins Inc. Box 3005 Columbus, IN 47202-3005 U.S.A. 1-800-CUMMINS™ (1-800-286-6467) cummins.com NAS-5778-EN (5/21) ©2021 Cummins Inc. ©2021 Cummins Inc. | NAS-5778-EN (7/21) A052G011 Permit #: 6657 Permit Date: 08/04/25 Permit Type: COMMERCIAL MECHANICAL Project Name: Generator Install Applicant Name: Farmers Electric Design and Construction Applicant Address: 2020 Maltby Rd #102 Applicant, City, State, Zip: Bothell, Wa, 98021 Contact: Ally Turner Phone: 8775906139 Email: service@farmerselectric.net Scope of Work: installation of natural gas generator and gas piping Valuation: 53000.00 Square Feet: 4565 Number of Stories: 2 Construction Type: VB Occupancy Group: ID Code: Permit Issued: 10/23/2025 Permit Expires: 04/22/2026 Form Permit Type: COMMERCIAL MECHANICAL Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 699 Other MINA PROPERTIES 00746300001400 19603 60TH AVE NE Miscellaneous II LLC Services NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License # 2020 Maltby Rd ELECTRICAL Farmers Electric D & C Tom Brown 425-508-1813 COA 602 980 144 #102 CONTRACTOR 2020 Maltby Rd ELECTRICAL Electrical Farmers Electric D & C Tom Brown 425-508-1813 FARMEED904B1 #102 CONTRACTOR Contractor Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C08. GAS PIPING 12/04/2025 12/05/2025 12/05/2025 BUILDING Approved ROUGH-IN C03. add Dobies under rebar to 10/13/2025 10/14/2025 10/14/2025 BUILDING Approved FOUNDATION/SLAB elevate off of ground Plan Reviews Date Review Type Description Assigned To Review Status COMMERCIAL 09/09/2025 See notes. PLANNING Pending Corrections MECHANICAL COMMERCIAL 09/09/2025 BUILDING Approved MECHANICAL Fees Fee Description Notes Amount Mechanical Commercial Plan Review Table 4-1 $649.40 Credit Card Service $19.48 Processing/Technology $25.00 Gas Piping/Units Enter # of units $15.00 Mechanical Base Permit Fee $25.00 Mechanical Misc. Not otherwise specified $15.00 Credit Card Service $2.40 Total $751.28 Attached Letters Date Letter Description 10/13/2025 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 08/04/2025 Alexandra Turner 239090556 $19.48 XBP Conf: 08/04/2025 $649.40 239090556 10/13/2025 Kevin Breiwick cc $2.40 XBP Conf: 10/13/2025 $80.00 245673462 Outstanding Balance $0.00 Notes Date Note Created By: 08/04/2025 pending site plan, gas piping drawing and spec sheet. Emailed applicant. Hannah Hardwick Uploaded Files Date File Name 10/23/2025 29027604-2025_BLD6657_Issued Permit.pdf 10/13/2025 28855472-20250909_BLD6657_Approved Site Plan.pdf 09/09/2025 28181083-20250804_BLD6657_Spec Sheet.pdf 09/09/2025 28181079-20250909_BLD6657_Site Plan.pdf 08/04/2025 27641068-20250804_BLD6657_App.pdf