Loading...
HomeMy WebLinkAbout309 S Dunham Ave_BLD6327_2025 RESIDENTIAL BUILDING PERMIT APPLICATION Community and Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 The following information is required for Residential: Single Family, Duplex, Townhomes, Additions, and Accessory Structure Building Permit Applications. Mark each box to designate that the information has been provided. Please submit this checklist as part of the submittal documents. EACH BUILDING OR STRUCTURE REQUIRES A SEPARATE SUBMITTAL. Incomplete applications will not be accepted. SUBMIT ELECTRONIC FILES FOR EACH OF THE FOLLOWING: REQUIRED DOCUMENTS Proof of approved Zoning Verification City of Arlington Residential Permit Application Site Plan Architectural Plans Structural Plans Structural Calculations Project Specification Manuals, if applicable WSEC Compliance Forms https://waenergycodes.com/ Special Inspection and Testing Agreement, if applicable Deferred Submittal Request, if applicable 1. Plan Review fee is due at time of submittal and remaining balance will be due at time of issuance. 2. The City of Arlington does not review or inspect electrical systems. Contact Labor and Industries at lni.wa.gov or 360-416-3000. A. DEFERRED SUBMITTALS If the project requires any of the following, a Deferred Submittal Request MUST be completed. Deferred submittals require separate applications, plans and plan review. 1. Mechanical Plans (if not included in the plan set) 2. Plumbing Plans (if not included in the plan set) 3. Fire Sprinkler B. SPECIAL INSPECTION AND TESTING AGREEMENT A Special Inspection Firm is required to perform special inspections for the following type of work. *The Special Inspection and Testing Agreement MUST be submitted with the Building Application. Structural Masonry Spray-Applied Fireproofing Other - Specify: ____________________ I acknowledge that all items designated as submittal requirements must accompany my Building Permit Application to be considered a complete submittal. RESIDENTIAL BUILDING Type of Permit: Single-family Duplex Townhouse Addition/Alteration Accessory Structure IBC Construction Type: IBC Occupancy Type: Building Square Footage: Number of Stories: Square Footage Per Floor: B: 1st: 2nd: 3rd: Garage: Property Address: Project Valuation: Lot #: Parcel ID No.: Preferred Contact:  Owner  Contractor Project Scope of Work: Owner Name: Home No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Primary Contractor: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: MECHANICAL SYSTEM INFORMATION  Not Applicable Type of Permit:  New Installation  Addition/Alteration/Repair  Gas Piping Mechanical Contractor: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances REV03.2022 Page 2 of 6 RESIDENTIAL BUILDING MECHANICAL PERMIT FEES (per unit) Type of Fixture No. of Units Cost per Unit Subtotal Model No. Additional Plan Review fees x $ 75.00 = Air Cond. Unit ≤100Btu/h x $ 15.00 = Air Cond. Unit >100Btu/h x $ 25.00 = Air Cond. Unit >500Btu/h x $ 50.00 = Air Handling Units x $ 15.00 = Base Mechanical Fee 1 x $ 25.00 = $ 25.00 Boiler <100Btu/h >3hp x $ 15.00 = Boiler >1 million Btu/h<50hp x $ 25.00 = Boiler >1.5 million Btu/h<50hp x $ 50.00 = Boiler >100Btu/h 3-15hp x $ 15.00 = Boiler >500Btu/h 15-30hp x $ 25.00 = Diffusers x $ 15.00 = Dryer Ducting x $ 15.00 = Ductwork (drawings required) x $ 25.00 = Evaporative Coolers x $ 15.00 = Exhaust/Ventilation Fans x $ 15.00 = Fireplace/Insert/Stove x $ 15.00 = Forced Air Heat ≤100 Btu/h x $ 15.00 = Forced Air Heat >100 Btu/h x $ 25.00 = Gas Clothes Dryer x $ 15.00 = Gas Fired AC ≤100 Btu/h x $ 15.00 = Gas Fired AC >100 Btu/h x $ 25.00 = Gas Fired AC > 500 Btu/h x $ 50.00 = Gas Piping ≤ 5 units x $ 15.00 = Gas Piping > 5 units (plus <5 units) x $ 2.00 = Heat Exchangers x $ 15.00 = Heat Pump-Condensing Unit x $ 25.00 = Hot Water Heat Coils x $ 15.00 = Miscellaneous Appliance - regulated by $ 15.00 x = mechanical code, not otherwise specified Pkg. Units ≤100btu x $ 25.00 = Pkg. Units >100btu x $50.00 = Range/Cook top-Gas Fired x $ 15.00 = Refrigeration Unit ≤100Btu/h x $ 15.00 = Refrigeration Unit >100Btu/h x $ 25.00 = Refrigeration. Unit >500Btu/h x $ 50.00 = Re-inspection fee x $ 75.00 = Residential Range Hood x $ 15.00 = Unit Heaters ≤ 100 Btu/h x $ 15.00 = Unit Heaters >100 Btu/h x $ 25.00 = VAV Boxes (Variable Air Volume, part of air $ 10.00 x = conditioning system) Wall Heaters - Gas Fired x $ 25.00 = Water Heater - Gas Fired x $ 25.00 = Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total REV03.2022 Page 3 of 6 RESIDENTIAL BUILDING GAS PIPING INFORMATION  Not Applicable Proposed Piping Material:  CSST  Brass  Galvanized Steel  Black Steel  Other _______________ Proposed Piping Size:  ½”  ⅝”  ¾”  1”  1½”  2” Distance from Meter to furthest Appliance: Total BTU’s of all Appliances: PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY – USE A SEPARATE SHEET, IF NECESSARY  SCHEMATIC IS TO SCALE  SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated REV03.2022 Page 4 of 6 RESIDENTIAL BUILDING PLUMBING SYSTEM INFORMATION  Not Applicable Type of Permit:  New Installation  Addition/Alteration/Repair Plumbing Contractor: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) • Cross-Connection-Control may be required Proposed Interior Water Piping Size: ½”  ⅝”  ¾”  1”  CPVC Brass PEX-AL-PEX PEX Proposed Interior Piping Material: Copper Galvanized Steel Other _______________________ Proposed Exterior Water Piping Size: ½”  ⅝”  ¾”  1”  1½”  2”  PVC Copper PEX-AL-PEX PEX-AL-PE Proposed Exterior Piping Material:  PE PEX Other Schedule 40 ABS DWV Copper Galvanized Steel  Cast Iron Proposed Drain-Waste-Vent (DWV) Material: Schedule 40 PVC DWV Brass Other: ________________________________ Proposed Drain-Waste-Vent (DWV) ½”  ⅝”  ¾”  1”  1½”  2”  3” 4” Piping Size: PLUMBING PERMIT FEES (per fixture) Type of Fixture No. of Fixtures Cost per Fixture Subtotal Additional Plan Review fees x $ 75.00 = Alteration/repair piping x $ 15.00 = Backflow Assembly x $25.00 = Base Plumbing Fee 1 x $ 25.00 = $25.00 Bath/Shower Combo x $ 15.00 = Building Main Waste x $ 25.00 = Clothes Washer x $ 15.00 = Dishwasher x $ 15.00 = Floor Drains x $ 15.00 = Grease Interceptor x $ 75.00 = Grease Trap x $ 25.00 = Hose Bibb x $ 15.00 = REV03.2022 Page 5 of 6 RESIDENTIAL BUILDING PLUMBING PERMIT FEES (per fixture) Icemaker/Refrigerator x $ 15.00 = Irrigation – per meter x $ 25.00 = Kitchen Sink & Disposal x $ 15.00 = Laundry Tray x $ 15.00 = Lavatory x $ 15.00 = Miscellaneous – regulated by plumbing code, not x $ 15.00 = otherwise specified Re-inspection Fee x $ 75.00 = Roof Drains x $ 15.00 = Shower (only) x $ 15.00 = Sink (bar, service, etc.) x $ 15.00 = Toilets x $ 15.00 = Urinal x $ 15.00 = Vacuum Breakers x $ 25.00 = Water Heater x $ 25.00 = MODEL NO.: Water Heater – Tankless x $ 25.00 = MODEL NO.: Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total I hereby certify that I am the Owner Architect Engineer Contractor and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above- described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. Signature Print Name Date REV03.2022 Page 6 of 6 LIST OF DRAWINGS Sheet Number Sheet Name Current Revision 309 S DUNHAM AVE ADDITION A0.0 COVER PAGE A0.1 GENERAL NOTES A0.2 NOTES & SCHEDULES A1.1 SITE PLAN A2.0 REMODEL/ADDITION FLOOR PLANS A2.1 ELECTRICAL & MECHANICAL A2.2 ROOF PLAN A3.0 DEMOLITION PLAN A3.1 FOUNDATION & FRAMING PLAN A4.0 ELEVATIONS A4.1 ELEVATIONS AND SECTIONS A4.2 WALL SECTIONS AND STAIRS A5.0 3D EXTERIOR A5.1 3D EXTERIOR A5.2 3D INTERIOR VICINTY MAP PROJECT TEAM PROJECT INFORMATION PROJECT NAME: TONY AND HEIDI SMITH OWNER: TAX ID #: 00538300201300 TONY AND HEIDI SMITH LOCATION: 309 S DUNHAM AVE 309 S DUNHAM AVE ARLINGTON, WA 98223 ARLINGTON, WA 98223 PROJECT #: NOT ASSIGNED OTHER PERMITS: NONE DESIGNER/APPLICANT: ZONE: OLD TOWN RESIDENTIAL DISTRICT GARRETT CHARLSON LOT SIZE: .21 ACRES OR 9147SF SNOVALLEY COTTAGES USE: SINGLE FAMILY RESIDENTIAL PO BOX 754 PROJECT DESCRIPTION: REMODEL AND ADDITION OF EXISTING SFR, ADDITION DUVALL, WA 98019 TO REAR OF HOUSE AND FRONT PORCH, BEDROOM p425.518.0036 COUNT TO REMAIN THE SAME Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. LEGAL DESCRIPTION: PALMER ADD TO ARLINGTON BLK 002 D-00- ALL LOTS No. GEOTECHNICAL ENGINEER: 13 & 14 N/A STRUCTURAL ENGINEER: COLIN ANYAN VIRTUS ENGINEERING SPRINKLERS: N/A PO BOX 30351 ECA: N/A SPOKANE, WA 99223 Issue Date SEPTIC: N/A - CITY SEWER p509.220.8766 LAND USE CODE COMPLIANCE ZONE: OLD TOWN RESIDENTIAL DISTRICT (OTRD) COVER PAGE Drawn by:Author IMPERVIOUS COVERAGE: LOT AREA: 9147 SF EXISTING SFR (OVERHANGS): 1597 SF Scale: EXISTING GARAGE (OVERHANGS): 616 SF EXISTING DRIVEWAY HARDSCAPE : 528 SF EXISTING WALKWAY HARDSCAPE : 150 SF ALLOWED LOT COVERAGE - NOT DEFINED: EXISTING LOT COVERAGE: 2891 SF NEW PROPOSED ADDITION (OVERHANGS): 767 SF NEW TOTAL LOT COVERAGE: 2891 SF + 767 SF = 3658SF REQ. SETBACKS: FRONT (STREET): AVERAGE TO ADJACENT LOTS CALC-NORTH 6.76' SOUTH SIDES (INTERIOR): 7.36, AVG. 7.06' REAR: 5 FEET 5 FEET HEIGHT LIMIT: BASE HEIGHT: 24' MAX TO EAVE ARLINGTON, WA 309 S DUNHAM AVE PROPOSED MAX. BUILDING HEIGHT: 9' TO EAVE AND 15' TO RIDGE 309 S DUNHAM AVE ADDITION Job No.: 23-15 A0.0 GENERAL DESIGN NOTES WSEC ENERGY NOTES MECHANICAL NOTES PLUMBING NOTES 1. COMPLY WITH CITY OF ARLINGTON CODES, 2021 IRC (INTERNATIONAL RESIDENTIAL CODE), 2021 WSEC ENERGY NOTES 1. ALL PLUMBING WORK IS TO BE BIDDER DESIGNED AND SHALL COMPLY WITH ALL WASHINGTON STATE ENERGY CODE, AND ALL APPLICABLE CODES AND ORDINANCES OF THE LOCAL 1. DESIGN TEMPERATURE: 49 DEGREES (70 INDOOR-21 OUTDOOR) 1. ALL MECHANICAL WORK TO BE BIDDER DESIGNED AND SHALL COMPLY WITH ALL APPLICABLE APPLICABLE CODES AND ORDINANCES. JURISDICTION AND THE STATE OF WASHINGTON. CODE: 2021 WASHINGTON STATE ENERGY CODE COMPLIANCE: USER DEFINED BASELINE- CODES. ADDITION/REMODEL/ALTERATION OF EXISTING 2. PROVIDE PRESSURE RELIEF VALVE FOR HOT WATER TANK. DRAIN TO THE OUTSIDE OF 2. DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS, REFER TO DETAILS FOR LOCATION OF ITEMS NOT 2. THE MECHANICAL WORK MUST ADHERE TO THE REQUIREMENTS OF THE DESIGN DRAWINGS. THE BUILDING WITH DRAIN END NOT MORE THAN 2 FEET NOR LESS THAN 6 INCHES DIMENSIONED ON PLANS, VERIFY UNKNOWN DIMENSIONS WITH DESIGNER. FROM THE GROUND, POINTING DOWN. BASELINE INSULATION AND FENESTRATION PROVIDED 3. VENTILATION SHALL BE IN CONFORMANCE WITH WAC 51-11 AND WAC 51-13, 2021 IRC CHAPTER 3. IT IS THE RESPONSIBILITY OF CONTRACTOR TO DO DUE DILIGENCE RELATED TO EXISTING SITE EXISTING STRUCTURE 15, TABLES M1507.4 AND M1507.3.3(1). 3. HOT WATER HEATERS SHALL BE ELEVATED PER 2021 IRC P2801.6. CONDITIONS PRIOR TO SUBMITTING PLANS FOR BID. WINDOW U FACTOR 0.40 (ESTIMATED) .30 4. HOT WATER TANKS SHALL BE STRAPPED OR ANCHORED AT POINTS WITHIN THE UPPER 4. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION, WHERE CONDITIONS ARE NOT 1/3 AND LOWER 1/3 TO RESIST EARTHQUAKE MOTION. SPECIFICALLY INDICATED BUT ARE OF SIMILAR CONSTRUCTION OF THOSE SHOWN, SIMILAR DETAILS CAN SKYLIGHT U FACTOR .50 .30 BE USED SUBJECT TO REVIEW AND APPROVAL OF DESIGNER AND STRUCTURAL ENGINEER. 5. PROVIDE AN APPROVED BACK-FLOW DEVICE AT ALL HOSE BIBS. GLAZED FENESTRATION SHGC N/A N/A RATED ASSEMBLIES - N/A 5. ALL WOOD FRAMING DETAILS NOT SHOWN SHALL BE CONSTRUCTED PER THE MINIMUM STANDARDS SET 6. ADDITIONAL NOTES LOCATED ON ELECTRICAL MECHANICAL PLAN SHEETS. FORTH IN THE 2021 IRC. CEILING R-19 R-49 FLAT R-30 VAULT 6. VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THIS CONTRACT OR BY OTHERS. ALL ABOVE GRADE WALL R-13 R-13 OLD AND R21+R6.6Ci NEW ELECTRICAL NOTES ROUGH-INS SHALL BE APPROVED AND FIREBLOCKING SHALL BE INSTALLED PRIOR TO FRAMING INSPECTION. BELOW GRADE WALL NOT INSULATED R13 + R5Ci 1. ALL ELECTRICAL WORK IS TO BE BIDDER DESIGNED AND SHALL COMPLY WITH ALL APPLICABLE 7. BUILDING SYSTEMS NOT DETAILED SHALL BE INSTALLED PER MANUFACTURERS REQUIREMENTS. NOTIFY FLOORS NOT INSULATED R-30 CODES AND ORDINANCES. INCLUDED ELECTRICAL PLAN IS FOR LAYOUT AND DESIGN DESIGNER OF ANY CONFLICTS. REFERENCE, ALL LOCATIONS TO BE FIELD VERIFIED WITH CONTRACTOR AND/OR OWNER PRIOR SLAB ON GRADE NOT INSULATED NOT INSULATED TO INSTALLATION. 8. PLUMBING AND MECHANICAL DRAWINGS ARE SUPPLEMENTARY TO THE TO THE DESIGN DRAWINGS. IT IS THE RESPONSIBILITY OF EACH OF THE CONTRACTORS TO THE DESIGN DRAWINGS PRIOR TO INSTALLATION GLAZING AREA UNLIMITED UNLIMITED 2. ADDITIONAL NOTES LOCATED ON ELECTRICAL AND MECHANICAL PLAN SHEETS. OF THEIR WORK, ANY CONFLICTS BETWEEN THE TWO SHALL BE BROUGHT TO THE OWNERS ATTENTION IN WRITING. DOORS .50 (ESTIMATED) .30 VENTILATION NOTES 9. CONTRACTOR TO PROVIDE TEMPORARY BRACING FOR ALL STRUCTURE AND COMPONENTS UNTIL CONNECTIONS HAVE BEEN MADE. 1. SYSTEM TYPE: WHOLE HOUSE FAN ON TIMER 10. ALL GLAZING IN HAZARDOUS LOCATIONS, DEFINED BY THE 2021 IRC R308.4, SHALL BE SAFETY GLAZING IDENTIFIED IN THE FLOOR PLANS AND GLAZING SCHEDULE. 2. SPECIFICS: SEE MECHANICAL PLANS, SHEET A2.1 11. PROVIDE FOOTING BEARING PER GEOTECHNICAL ENGINEER RECOMMENDATIONS. WSEC ENERGY CREDIT NOTES 3. ADDITIONAL NOTES LOCATED ON FLOOR PLAN SHEETS 12. "FINISH FLOOR" REFERS TO: • THE TOP OF SLAB AT BASEMENT CREDIT REQUIREMENTS PER R406.3 DWELLING SIZE: ADDITIONS 150-500SF CREDITS REQUIRED: 2 • TOP OF FLOOR SHEATHING AT MAIN FLOOR CREDITS PROVIDED: 3 • TOP OF SHEATHING AT UPPER FLOOR (3 CREDITS) HEATING OPTION 4 13. VERIFY SIZE AND LOCATION OF AND PROVIDE ALL OPENINGS THROUGH FLOORS AND WALLS, FURRING, VARIABLE REFRIGERANT HEAT PUMP OR AIR-TO-WATER HEAT PUMP DEFERRED SUBMITTALS ANCHORS, INSERTS, ROUGH BUCKS AND BACKING FOR SURFACE MOUNTED ITEMS. FOR HEATING SYSTEM USING A HEAT PUMP THAT MEETS FEDERAL STANDARDS FOR THE 14. PROVIDE FURRING AS REQUIRED TO CONCEAL MECHANICAL AND ELECTRICAL WORK IN ALL FINISHED EQUIPMENT LISTED IN TABLE C403.3.2(2) OR TABLE C403.3.2(9) OR AIR TO WATER HEAT AREAS. PUMP UNITS THAT ARE CONFIGURED TO PROVIDE BOTH HEATING AND COOLING AND ARE RATED IN 1. HEAT PUMP SPECIFICATIONS ACCORDANCE WITH AHRI 550/590 2. TRUSS DRAWINGS IF APPLICABLE 15. UNLESS OTHERWISE NOTED, ALL PLAN DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE. 16. EXTERIOR WALLS SHALL BE 2X6 STUDS AT 24" O.C. AND INTERIOR WALLS SHALL BE 2X4 STUDS AT 24" TOTAL CREDITS: 3 O.C., UNLESS NOTED OTHERWISE. 17. ALL SWINGING DOORS NOT LOCATED BY DIMENSIONS ON PLANS, INTERIOR ELEVATIONS, OR DETAILS SHALL BE 4-1/2" FROM FACE OF STUD TO EDGE OF ROUGH OPENINGS OR CENTERED BETWEEN ROOM PARTITIONS AS SHOWN. 18. PLANS ARE DRAWN ASSUMING THE FOLLOWING ROUGH OPENINGS: EXTERIOR DOOR WIDTH: NOMINAL SIZE + 2" (VERIFY WITH DESIGNER) WINDOW WIDTH: NOMINAL SIZE + 0" (VERIFY WITH DESIGNER) WINDOW HEIGHT: NOMINAL SIZE + 0" (VERIFY WITH DESIGNER) INTERIOR SWINGING DOORS: NOMINAL SIZE Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. +2". INTERIOR POCKET DOORS: PANEL SIZE + 1" BI-PASS DOORS: NOMINAL SIZE +0". 19. REFER TO CABINET DESIGNER PLANS FOR CABINET AND COUNTER LENGTHS, DIMENSIONS, No. COUNTERTOP MATERIALS AND DETAIL REFERENCE. VERIFY ALL EXISTING DIMENSIONS BEFORE ORDERING AND PRIOR TO INSTALLATION. 20. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR EXPOSED TO THE WEATHER SHALL BE PRESSURE TREATED WITH AN APPROVED PRESERVATIVE OR DECAY RESISTANT NATURALLY DURABLE WOOD. FASTENERS FOR PT MATERIALS SHALL BE HOT DIPPED GALVANIZED STEEL, STAINLESS STEEL SILICON BRONZE COPPER OR APPROVED FASTENER FOR PRESSURE TREATED CONTACT. 21. ALL WOOD LESS THAN 8" FROM THE GROUND OR 2" FROM EXTERIOR CONCRETE (SLABS, STEPS, AND SIMILAR HORIZONTAL SURFACES) AND EXPOSED TO WEATHER SHALL BE NATURALLY DURABLE OR PRESSURE TREATED PER 2021 IRC R317. 22. PROVIDE FIRE BLOCKING VERTICALLY AT CEILING AND FLOOR LEVELS AND HORIZONTALLY AT INTERVALS NOT TO EXCEED 10 FEET AD AS REQUIRED FOR CONCEALED SPACES PER 2021 IRC R302.11 AND R302.12. Issue Date 23. ALL EMERGENCY ESCAPES AND RESCUE OPENINGS SHALL MEET THE REQUIREMENTS OF 2021 IRC R310. 24. ROOF VENTILATION SHALL MEET THE REQUIREMENTS OF 2021 IRC R806. 25. WEATHER PROOFING SHALL MEET THE REQUIREMENTS OF 2021 IRC R903. 26. GUARDRAILS AND OPEN RAILINGS SHALL MEET THE REQUIREMENTS OF 2021 IRC R312. GENERAL NOTESDrawn by:Author GEOTECHNICAL NOTES 1. REPORT NOT REQUIRED Scale: 12" = 1'-0" ARLINGTON, WA 309 S DUNHAM AVE 309 S DUNHAM AVE ADDITION Job No.: 23-15 A0.1 ROOMS SCHEDULE ALL NOTES PROJECT LEGEND(S) ROOM NAME AREA COMMENTS NO. DESCRIPTION View Type Count (N) BEDROOM 2 123 SF 1 (N) ASPHALT ROOF ELEVATION 2 GENERAL SYMBOLS WALL ASSEMBLIES (N) BATH 47 SF 2 WRAP POSTS IN PWW ELEVATION 3 2X4 INTERIOR WALL (N) DINING 196 SF 3 HARDIE LAP SIDING-8" REVEAL, VERIFY WITH OWNER ELEVATION 3 • 1/2 GYPSUM (N) KITCHEN 252 SF 4 TREX DECK FASCIA ELEVATION 3 1 PLAN NOTE W1 • 2X4" DF (N) BONUS ROOM 564 SF 5 1X6 PWW TRIM OR HARDIE TRIM ELEVATION 1 • 1/2 GYPSUM SPOT ELEVATION (N) BATH 43 SF 6 (N) 5" GUTTER ELEVATION 1 • INSULATE AROUND CL. 24 SF CLOSET, TYP. 7 TREX DECKING OR EQUIV. ELEVATION 2 BATHROOMS & BEDROOMS E E ELECTRIC (N) MECH. 57 SF 8 1X10 PWW TRIM OR HARDIE TRIM ELEVATION 1 2X6 INTERIOR WALL (N) OFFICE 47 SF 1 EXISTING SEWER ~5' ABOVE FFE FLOOR PLAN 1 W W WATER • 1/2 GYPSUM (N) BEDROOM 3 80 SF 2 EXISTING ELECTRICAL PANEL-150 AMP, UPGRADE TO 200 AMP FLOOR PLAN 1 W2 • 2X6" DF DS • 1/2 GYPSUM (N) STORAGE 54 SF 1 VENT HOOD MIN. 100CFM MEP 1 DOWNSPOUT • INSULATE AROUND CL. 13 SF CLOSET, TYP. 2 BATHROOM EXHAUST FAN MIN. 50CFM MEP 2 BATHROOMS & BEDROOMS LINEN 4 SF 3 PANASONIC WHISPER 50/80/110 ON TIMER MEP 1 HD HEAT DETECTOR 2X4 EXTERIOR WALL R-15: (E) MASTER BEDROOM 135 SF 4 RHEEM PROTERRA-INTAKE AND EXHAUST TO EXTERIOR MEP 1 • 1/2 GYPSUM (N) BATHROOM 36 SF 5 MITSUBISHI HYPERHEAT HEAT PUMP MEP 1 S/CM SMOKE/CO2 DETECTOR • 2X4" DF W3 CL. 12 SF CLOSET, TYP. 6 MITSUBISHI AIR HANDLER IN MECH. MEP 1 • BLOWN IN CELLULOSE OR BATT R-15 SHOWER/TOILET 34 SF 1 SOLAR READY ZONE ROOF 1 • SIDING PER OWNER SPEC. (N) GREAT ROOM 478 SF 2 DOWNSPOUT TO TIGHTLINE TO DRYWELL ROOF 2 2199 SF 3 30-YEAR ASPHALT ROOF ROOF 1 Grand total: 18 2199 SF 4 DOWNSPOUT TO TIGHTLINE TO RAIN GARDEN OR SWALE ROOF 3 2X6 EXTERIOR WALL R-26: 5 OVERFRAME ROOF 4 • 1/2 GYPSUM OVER EXISTING W4 • 2X6" DF ROOF PER STRUC. SITE PLAN LEGEND • BLOWN IN CELLULOSE OR BATT R-20 OVERFRAME OVER EXISTING ROOF PER STRUC. • 1 1/2" ZIP R-SHEATHING R-6 DOOR SCHEDULE • SIDING PER OWNER SPEC. DOOR ROOM DOOR NO. DISTURBED AREA - 2x4 BASEMENT WALL: TYPE FROM TO HEIGHT WIDTHAREA Phase Created • NO WATERPROOF COATING ON CONCRETE C104 - STAKE & WIRE FENCING • 2" RIGID EPS FOAM BASEMENT FF W5 • 2X4 STUD WALL W/ MINERAL WOOL INSUL. R-15 SOLID CORE INTERIOR (N) BONUS (N) BONUS ROOM 80" 30" 17 SF Existing C233 SILT FENCE OR MULCH BERM • 1/2" GYPSUM DEMO ROOM DS • NON-PVA WALL PRIMER SOLID CORE INTERIOR (N) BONUS (N) BONUS ROOM 80" 30" 17 SF Existing DOWNSPOUT • LOW OR NO VOC LATEX PAINT DEMO ROOM D19 SOLID CORE INTERIOR (N) MECH. (N) BONUS ROOM 80" 30" 17 SF New 1 PLAN NOTE (E) BASEMENT WALL: SOLID CORE INTERIOR (N) BONUS (N) STORAGE 80" 28" 16 SF New W6 • 6" POURED CONCRETE WALL D16 SPOT ELEVATION ROOM SOLID CORE INTERIOR (N) BONUS (N) OFFICE 80" 30" 17 SF New E E D20 ELECTRIC ROOM SOLID CORE INTERIOR (N) BONUS (N) BEDROOM 3 80" 30" 17 SF New W W WATER D18 ROOM FLOOR ASSEMBLIES D17 SOLID CORE INTERIOR LINEN (N) BONUS ROOM 80" 20" 11 SF New D21 BI-PASS CLOSET CL. (N) BEDROOM 3 80" 60" 33 SF New EXISTING SLAB ON GRADE CONDITIONED: • 4" CONCRETE SOLID CORE INTERIOR (N) BONUS (N) BONUS ROOM 80" 30" 17 SF New D15 MEP LEGEND • APPLY SELF LEVELER, PREP PER MANUF. ROOM RECOMMENDATIONS D14 SOLID CORE INTERIOR CL. (N) BONUS ROOM 80" 34" 19 SF New FL1 • UNDERSLAB CONDITIONS UNKNOWN D13 SOLID CORE INTERIOR (N) BATH (N) BONUS ROOM 80" 30" 17 SF New CEILING LIGHT • RECOMMENDED NO CARPET AT BASEMENT 196 SF • INSTALL VAPOR RETARDER UNDER FLOORING MAIN LEVEL DEMO SOLID CORE INTERIOR (N) GREAT ROOM (N) GREAT ROOM 80" 24" 13 SF Existing WALL LIGHT FLOOR OVER CRAWLSPACE: DEMO SOLID CORE INTERIOR (N) GREAT ROOM CL. 80" 28" 16 SF Existing • FINISH FLOORING PER OWNER SPEC. Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. FL2 • 3/4 T&G FLOOR SHEATHING SOLID CORE INTERIOR (N) GREAT ROOM (E) MASTER 80" 30" 17 SF Existing CAN LIGHT • 11 7/8 TJI D8 BEDROOM • BATT INSULATION R-30 No. DEMO BI-PASS CLOSET (N) BEDROOM 2 (N) BEDROOM 2 80" 60" 33 SF Existing • VENTED CRAWLSPACE BI-PASS CLOSET (E) MASTER 80" 72" 40 SF Existing SIGLE OUTLET • 10MIL VAPOR BARRIER OVER GROUND D9 BEDROOM DEMO SOLID CORE INTERIOR (N) GREAT ROOM (N) GREAT ROOM 80" 30" 17 SF Existing DUPLEX OUTLET FLOOR OVER CONDITIONED: • FINISH FLOORING PER OWNER SPEC. DEMO SOLID CORE INTERIOR (N) GREAT ROOM (N) BEDROOM 2 80" 30" 17 SF Existing FL3 • 3/4 T&G FLOOR SHEATHING SWITCH DEMO SOLID CORE INTERIOR SHOWER/TOILET (N) BEDROOM 2 80" 24" 13 SF Existing • 2X8 ROUGH SAWN FLOOR JOISTS D6 SOLID CORE INTERIOR (N) GREAT ROOM (N) BEDROOM 2 80" 30" 17 SF Existing • 5/8 GYPSUM 3 SWITCH - 3 WAY D1 EXTERIOR INSULATED (N) GREAT ROOM 80" 36" 20 SF New D7 SOLID CORE INTERIOR (N) GREAT ROOM (N) GREAT ROOM 80" 30" 17 SF New EXTERIOR PATIO FULL (N) DINING 80" 72" 40 SF New R OUTLET 220V SEE SPECIFIC EQUIPMENT D3 SPEC. IF AVAIL. LITE ROOF ASSEMBLIES EXTERIOR PATIO FULL (N) DINING 80" 72" 40 SF New FLOOR OUTLET D2 LITE D11 POCKET DOOR SHOWER/TOILET (N) BATHROOM 80" 30" 17 SF New HRVB HRV BOOSTER SWITCH VENTED ROOF R-38: Issue Date D4 SOLID CORE INTERIOR (N) GREAT ROOM (N) BATH 80" 30" 17 SF New • 30-YEAR ASPHALT ROOFING D10 BI-PASS CLOSET (N) BATHROOM CL. 80" 60" 33 SF New • WRB WATER-30# TAR PAPER PLUMBING WALL (VERIFY FIXTURE R1 D12 BI-PASS CLOSET (N) BEDROOM 2 80" 60" 33 SF New LOCATION WITH CABINETRY &/OR • 1/2" PLYWOOD SHEATHING D5 SOLID CORE INTERIOR (N) GREAT ROOM 80" 32" 18 SF New PRODUCT SPEC. • 2X OR LVL RAFTERS PER STRUC. • VENTED RIDGE D22 SOLID CORE INTERIOR (N) GREAT ROOM (N) BEDROOM 2 80" 30" 17 SF New • INSULATION TO MIN. R-38 W/BAFFLES 433 SF • 5/8" GYPSUM Drawn by:Author VENTED ROOF OVER UNCONDITIONED: NOTES & SCHEDULES WINDOW SCHEDULE • 30-YEAR ASPHALT ROOFING • WRB WATER-30# TAR PAPER R2 • 1/2" PLYWOOD SHEATHING MARK LOCATION STYLE SIZE (W x H) AREA U-VALUE UA SILL HEIGHT TEMPERED COMMENTS ROOF PLAN LEGEND • 2X OR LVL RAFTERS PER STRUC. • VENTED RIDGE F1 (N) DINING CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-2" YES • SOFFIT-T AND G PINE OR EQUIV. F2 (N) DINING CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-2" YES GUTTER (DOUBLE LINE) • EXTERIOR GRADE PAINT OR STAIN Scale: F3 (N) KITCHEN CASEMENT 2'-0" x 3'-6" 7 0.3 2.100 3'-0" VENT-FIXED-VENT 1/8" = 1'-0" F4 (N) KITCHEN FIXED 4'-0" x 3'-6" 14 0.3 4.200 3'-0" VENT-FIXED-VENT DOWNSPOUT LOCATION DS F5 (N) KITCHEN CASEMENT 2'-0" x 3'-6" 7 0.3 2.100 3'-0" VENT-FIXED-VENT F6 (N) GREAT ROOM FIXED 2'-6" x 4'-6" 11 0.3 3.375 2'-6" SOLAR READY AREA F7 (N) GREAT ROOM CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-6" VENT-FIXED-VENT F8 (N) GREAT ROOM FIXED 2'-6" x 4'-6" 11 0.3 3.375 2'-6" VENT-FIXED-VENT BUILDING OUTLINE F9 (N) GREAT ROOM CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-6" VENT-FIXED-VENT F10 (N) GREAT ROOM CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-6" VENT-FIXED-VENT F11 (N) GREAT ROOM FIXED 2'-6" x 4'-6" 11 0.3 3.375 2'-6" VENT-FIXED-VENT F12 (N) GREAT ROOM CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-6" VENT-FIXED-VENT F13 (N) GREAT ROOM FIXED 1'-6" x 5'-0" 8 0.3 2.250 1'-8" YES F14 (N) BATH AWNING 3'-0" x 1'-6" 5 0.3 1.350 5'-6" YES VENT-FIXED-VENT F15 (N) BEDROOM 2 CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-6" VENT-FIXED-VENT F16 (N) BEDROOM 2 FIXED 2'-6" x 4'-6" 11 0.3 3.375 2'-6" VENT-FIXED-VENT F17 (N) BEDROOM 2 CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-6" EGRESS F18 (N) BEDROOM 2 FIXED 2'-6" x 4'-6" 11 0.3 3.375 2'-6" FIXED-FIXED F19 (N) BEDROOM 2 FIXED 2'-6" x 4'-6" 11 0.3 3.375 2'-6" FIXED-FIXED F20 SHOWER/TOILET CASEMENT 2'-0" x 3'-6" 7 0.3 2.100 3'-6" YES F21 (E) MASTER CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-6" EGRESS BEDROOM F22 (E) MASTER SLIDER 5'-0" x 3'-6" 18 0.3 5.250 3'-5 1/2" EGRESS BEDROOM F23 (N) BEDROOM 3 CASEMENT 3'-0" x 3'-0" 9 0.3 2.700 3'-8" EGRESS F24 (N) OFFICE AWNING 3'-0" x 1'-6" 5 0.3 1.350 5'-7" 309 S DUNHAM AVEARLINGTON, WA F25 (N) BONUS ROOM AWNING 3'-0" x 1'-6" 5 0.3 1.350 5'-7" TOTAL: 25 251 75.375 309 S DUNHAM AVE ADDITION Job No.: 23-15 A0.2 POWER POLE ALLEYWAY 76'-0" 12'-0" VICINTY MAP 5'-0" SIDE YARD SETBACK 41'-7 5/8" TO PL 5'-0" REAR YARD SETBACK 5'-0" SIDE YARD SETBACK OVERHEAD POWER LINE 1 9 INTERNAL ORIGIN (0,0,0) I 3'-0" TO PL PROPOSED ADDITION2 34 5 7 8 H G EXISTING (E) ELECTRICAL PROPOSED ADDITION GARAGE METER BASE 120'-0 1/8" TO REMAIN F 27'-0" GAS E 22'-0" (E) GAS LINE LOCATION TO METER, METER TO BE REMOVED EXISTING 3'-1 1/4" PROJECT INFORMATION BY UTILITY, LINE ABANDONED. 3-BED RESIDENCE Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. PROJECT NAME: TONY AND HEIDI SMITH D No. TAX ID #: 00538300201300 C LOCATION: 309 S DUNHAM AVE 10'-7 1/2" TO PL FFE = 171.33 20'-6" ARLINGTON, WA 98223 B PROJECT #: NOT ASSIGNED 6 OTHER PERMITS: NONE A ZONE: OLD TOWN RESIDENTIAL DISTRICT 10 8'-2" 41'-0 1/4" LOT SIZE: .21 ACRES OR 9147SF 6'-1"AA PROPOSED 7'-0 3/4" USE: SINGLE FAMILY RESIDENTIAL EXISTING Issue Date PROJECT DESCRIPTION: REMODEL AND ADDITION OF EXISTING SFR, ADDITION 14'-1" PROPOSED PORCH DRIVEWAY TO REAR OF HOUSE AND FRONT PORCH, BEDROOM 22'-7 1/4" TO PL (E)WALKWAY 13'-9 1/8" 12'-0" COUNT TO REMAIN THE SAME 170'-0" 13'-5 1/2" 13'-1 7/8" SITE PLAN LEGAL DESCRIPTION: PALMER ADD TO ARLINGTON BLK 002 D-00- ALL LOTS 4'-11 3/4" AVG. SETBACK ADJACENT Drawn by:Author 13 & 14 ADJACENT PARCEL SETBACK TO ROOF OH ADJACENT PARCEL SETBACK TO ROOF OH LAND USE CODE COMPLIANCE OLD TOWN RESIDENTIAL DISTRICT (OTRD) (E) SIDEWALK ZONE: 7'-4" Scale: WATER METER LOC. APPROX. SEWER LINE LOC. As indicated IMPERVIOUS COVERAGE: PER SIDE SEWER AS BUILT DEPTH ~2' AT HOUSE, 8' AT PROPERTY LINE ON DUNHAM LOT AREA: 9147 SF 18'-0" EXISTING SFR (OVERHANGS): 1597 SF SOUTH DUNHAM AVE EXISTING GARAGE (OVERHANGS): 616 SF EXISTING DRIVEWAY HARDSCAPE : 528 SF NORTH EXISTING WALKWAY HARDSCAPE : 150 SF 36'-0" ALLOWED LOT COVERAGE - NOT DEFINED: EXISTING LOT COVERAGE: 2891 SF NEW PROPOSED ADDITION (OVERHANGS): 767 SF NEW TOTAL LOT COVERAGE: 2891 SF + 767 SF = 3658SF 1 SITE PLAN REQ. SETBACKS: A4.0 1" = 10'-0" FRONT (STREET): AVERAGE TO ADJACENT LOTS CALC-NORTH 6.76' SOUTH SIDES (INTERIOR): 7.36, AVG. 7.06' ARLINGTON, WA 309 S DUNHAM AVE REAR: 5 FEET SITE PLAN KEY NOTES SITE PLAN LEGEND EXPOSED SOILS SHALL BE WORKED DURING THE WEEK 5 FEET NO. DESCRIPTION UNTIL THEY HAVE BEEN STABILIZED. SOIL STOCKPILES HEIGHT LIMIT: WILL BE LOCATED WITHIN THE DISTURBED AREA SHOWN ON THE SWPPP. SOIL EXCAVATED FOR THE DISTURBED AREA - 309 S DUNHAM AVE ADDITION BASE HEIGHT: 24' MAX TO EAVE FOUNDATION WILL BE BACKFILLED AGAINST THE C104 - STAKE & WIRE FENCING PROPOSED MAX. BUILDING HEIGHT: 9' TO EAVE AND 15' TO RIDGE FOUNDATION AND GRADED TO DRAIN AWAY FROM THE BUILDING. NO SOILS SHALL REMAIN EXPOSED AND C233 SILT FENCE OR MULCH BERM UNWORKED FOR MORE THAN 2 DAYS FROM OCT. 1 TO DS APR. 30. ONCE THE DISTURBED LANDSCAPES ARE DOWNSPOUT GRADED, THE GRASS AREAS WILL BE RESEEDED OR 1 PLAN NOTE SODDED. ALL STOCKPILES WILL BE COVERED WITH Job No.: 23-15 PLASTIC OR BURLAP IF LEFT UNWORKED. SPOT ELEVATION E E ELECTRIC W W WATER A1.1 28'-0 1/2" _______2 14'-0 1/4" 14'-0 1/4" A4.0 10 1 2 2 3 4 5 6 7 8 9 10 _______ A4.1 1 3 4 5 7 8 9 H DIM. TO CL OF POST I G (N)GLULAM BEAM ABV. 39'-1 7/8" COVERED PORCH ADDITION VAULTED CEILING 4/12 SLOPE (N) VENTED CRAWLSPACE (N) FOUNDATION, SEE FDN PLAN GUARDRAILS REQUIRED IF DECK SURFACE MORE THAN 30" ABOVE GRADE 2 _______ _______4 A4.1 A4.2 WINDER REQUIRED 12'-9 1/4" TO MEET HEADROOM (E) FOUNDATION, SEE FDN PLAN PER CODE-6'-8" MIN. 13'-9 1/4" 14'-3 1/4" NEW ADDITION 9'-4 3/4" 4'-4 1/2" 2'-7 1/4" 4'-7" 4'-7" 2'-6" 4'-1" F DIM. TO F2 F1 FACE OF 3 DIM. TO CONC. _______ 9'-4 3/4" 4'-4 1/2" 9'-10 3/8" 2'-5 1/2" 6'-8 1/2" A4.2 9'-3 3/8" 9'-6 1/8" FACE OF D2 _______3 CONC. E H A4.0 (E) VENTED CRAWLSPACE W4 F5 F4 F3 3'-0" W4 4'-0" NEW ADDITION 2 G = W5 D13 (N) BATH 4'-1" 3'-4" 5'-10 1/4" (N) BEDROOM 3 3'-1 3/4"D21 DW DN 5'-0" CL. (N) STORAGE 5'-3 1/2" (N) DINING EGRESS REMOVE WINDOW D3 AND FILL IN WITH 11'-4 1/2" 8'-10 1/2" F23 = FRAMING ALIGN NEW FRAMING CONVERT TO EGRESS WINDOW STAIRS: W4 TO CORNER (E) WALL SILL AT +44" A.F.F. MAX. 14RISERS 1 3'-9 3/4" (N) KITCHEN AT 7" 2X4 INTERIOR WALL, TYP. _______ VAULTED CEILING 4/12 SLOPE REMOVE SIDING A4.1 S LINEN S 13'-1 7/8" WH 1/2" AIR GAP FROM CONCRETE 12'-0" ON EXT. WALL 5'-6 1/4" 2'-0" W3 F22 12'-10 1/8" STAIR OPENING 5'-8 5/8" Range D18 D17 D16 3'-6" 8'-0 3/8" FULL HEIGHT WALL F 3'-10" D19 2 D15 STUB FOR _______3 6'-4 7/8" S/CM _______ 7'-9 1/8" STAIR OPENING FUTURE SINK A4.2 (E) WIN. COULD REMAIN A4.2 1 24'-0" 3'-11 5/8" GRINDER (N) MECH. 2'-9 7/8" PUMP STORAGE CL VANITY ABV. _______3 ISLAND 10' X 5' S PANTRY (E) MASTER BEDROOM CLOSET A4.0 DBL OVEN 7'-10 1/8" D 28'-0" Oven E ALIGN 8'-1 1/4" D14 CL TOILET ABV. 3'-6" ALIGN WALL ON CENTER W/POST 28'-0" EXISTING BASEMENT FLUSH INSIDE FACE OF WALL 9'-0 5/8" OF POST 7'-0" (N) SKYLIGHT OVER THE STAIRS TO INSIDE FACE OF BEAM (N)GLULAM 2'-0" C BEAM ABV. (E) DOOR OPENING Refrigerator CL SHOWER DRAIN ABV. ALTER AS NEEDED PER DOOR CL VANITY ABV. 8'-8 1/8" W3 LOCATE WITHIN 3' OF PEAK D9 SELECTION F21 F24 W5 D20 CL WASHER ABV. Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. EGRESS (N) OFFICE (N) BONUS ROOM (N)6X6 POST-BEARING TO CABINETS/COUNTER 4'-0" 3'-3 1/2" 2'-10 1/4" 4'-0 1/8" 2'-4" 2'-6" F6 (N) WALL BELOW TO FTG. 5'-11 3/8" INSTALL PERMANENT W1 9'-2 3/4" DEHUMIDIFIER IN F25 2'-1 1/2" _______1 No. CL TOILET ABV. 3'-4 1/2" BASEMENT, DISCHARGE TO S A4.1 P-TRAP (N) BATHROOM 13'-4" TO CL OF (E) BEAM AND POSTS D8 CL. = B MATCH CL PLUMBING WALL ABV. DIM. TO = D10 CL SHOWER DRAIN ABV. 2'-11" WALL AT +42" A.F.F. D7 FACE OF 15'-6 1/2" W6 _______2 66" VANITY 5'-11 1/4" 4'-0" CONC. A4.2 DN 4'-9" = 5'-4" 15'-11 1/4" TO STAIR OPENING CLOSET 3'-10 7/8" 1'-2" MIRROR DIM. ON FIREPLACE CENTER 7'-9 1/8" = CONFIRM RO WITH POCKET DOOR SPECS (2)2X FIREPLACE D11 3 1/2" D 3'-3 1/2" SHOWER/TOILET A MATCH (N) GREAT ROOM = FLAT CEILING AT 7' 10-3/4" EXISTING RESIDENCE F20 4'-0" 2'-0" MIRROR DIM. ON FIREPLACE CENTER REBUILD FP AT INTERIOR (N)6x6 POST-BEARING TO METAL RAILING 3'-1" 3'-8 1/4"S/CM SHOWER 4'-3 1/2" F7 AT +36" A.F.F. 4' W X 3' D = Issue Date TO CENTER BEAM BELOW C ON BEAMS ABV. AND STAIR D4 D5 S ADD 2' X 2' SKYLIGHT ABOVE F8 7'-6" 9'-0 1/2" 30'-1 3/8" W1 (N) GLULAM BEAM ABV. 42" VANITY 4'-9 7/8" (N) BEDROOM 2 F19 Author F9 4'-2 1/2"4'-2 1/2" 3'-4 1/2"(N) BATH W2 1'-0" Drawn by: _______1 D12 5'-0" A4.0 BENCH/CUBBIES/CABS 9'-7 5/8" B 2 BASEMENT LEVEL 7'-6" W3 F18 1/4" = 1'-0" 6'-2 7/8" A4.0 1'-4 3/8"1'-4 3/8" CLOSET F10 F11 F12 1'-3 1/2" 4'-5 1/2"2'-10" 2'-2" 2'-4 1/2" 6'-7 7/8" 6'-7 7/8" 4'-9 7/8" REMODEL/ADDITION FLOOR PLANS 3'-1 3/8" EGRESS Scale: FLOOR PLAN NOTES D1 As indicated SMOKE ALARMS AND HEAT DETECTION A FRAMING: 2X6 EXTERIOR WALLS REQUIRED LOCATIONS R314.3: FRAMING - DOOR SCH. 1'-6" 3'-0" 7'-6" SMOKE ALARMS/CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN: 2X4/6's AT INTERIOR WALLS UNLESS NOTED OTHERWISE 1. IN EACH SLEEPING ROOM OR SLEEPING LOFT NO. DOOR SIZE HEAD HEIGHT COMMENTS F13 F14 F15 F16 F17 FILL IN 2X4 FRAMING 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE BASEMENT FF AT ALL MODIFIED SEE STRUCTURAL NOTES FOR STUD SCHEDULE. VICINITY OF THE BEDROOMS. D13 2'-6" 6'-8" 6'-8" COVERED WINDOW OPENINGS 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING CONCEALED SPACES SHALL BE FIRESTOPPED IN BOTH DIRECTIONS AT BASEMENTS AND HABITABLE ATTICS. D14 2'-10" 6'-8" 6'-8" NEW ADDITION PORCH 10" ON CENTER AND AT FLOORS. TYPICAL. 4. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET FROM D15 2'-6" 6'-8" 6'-8" THE DOOR OR OPENING OF A BATHROOM. D16 2'-4" 6'-8" 6'-8" ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH D17 1'-8" 6'-8" 6'-8" DN AA HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. THE LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER D18 2'-6" 6'-8" 6'-8" MINIMUM CLEAR OPENING HEIGHT DIMENSION SHALL BE 24". MINIMUM THAN 24". CLEAR OPENING WIDTH DIMENSION SHALL BE 20". SILL HEIGHT SHALL D19 2'-6" 6'-8" 6'-8" NOT BE MORE THAN 44" ABOVE THE FLOOR. ALTERATIONS, REPAIRS AND ADDITIONS R314.2.2 WHERE ALTERATIONS, D20 2'-6" 6'-8" 6'-8" REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHERE ONE OR D21 5'-0" 6'-8" 6'-8" _______1 SHOWER COMPARTMENTS AND WALLS AROUND BATHTUBS WITH MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DEMO 2'-6" 6'-8" 6'-8" A4.0 SHOWERS SHALL BE FINISHED WITH A SMOOTH NON-ABSORBANT DWELLINGS, OR WHERE AN ACCESSORY DWELLING UNIT IS CREATED DEMO 2'-6" 6'-8" 6'-8" SURFACE TO NOT LESS THAN 72" ABOVE THE FLOOR (IRC R307.2). WITHIN AN EXISTING DWELLING UNIT, EACH DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS AS REQUIRED FOR NEW DWELLINGS. MAIN LEVEL 2 6 ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN D1 3'-0" 6'-8" 6'-8" 1 MAIN LEVEL OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM OF 3/4" D2 6'-0" 6'-8" 6'-8" 1/4" = 1'-0" ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER A4.0 D3 6'-0" 6'-8" 6'-8" DOOR AND TRANSFER GRILLE ABOVE DOOR. HEAT DETECTION INTERCONNECTION R314.4.1 HEAT DETECTORS AND HEAT ALARMS SHALL BE CONNECTED TO AN ALARM OR A SMOKE ALARM D4 2'-6" 6'-8" 6'-8" PROVIDE WEATHER RESISTANT FIBER CEMENT WALLBOARD UNDER TUB THAT IS INSTALLED IN THE DWELLING. ALARMS THAT ARE INSTALLED FOR D5 2'-8" 6'-8" 6'-8" AND SHOWER ENCLOSURE MATERIALS TO A HEIGHT OF 70" MINIMUM THIS PURPOSE SHALL BE LOCATED IN A HALLWAY, ROOM, OR OTHER D6 2'-6" 6'-8" 6'-8" ABOVE THE DRAIN INLET. LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION. D7 2'-6" 6'-8" 6'-8" FLOOR PLAN KEY NOTES ARLINGTON, WA D8 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN COMBINATION ALARMS R314.5 COMBINATION SMOKE AND CARBON OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM ? 3/4" MONOXIDE ALARMS MAY BE USED IN PLACE OF SMOKE ALARMS. D9 6'-0" 6'-8" 6'-8" NO. DESCRIPTION ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D10 5'-0" 6'-8" 6'-8" 1 EXISTING SEWER ~5' ABOVE FFE DOOR AND TRANSFER GRILLE ABOVE DOOR. POWER SOURCE R314.6 SMOKE ALARMS, HEAT ALARMS, AND HEAT D11 2'-6" 6'-8" 6'-8" 2 EXISTING ELECTRICAL PANEL-150 AMP, UPGRADE TO 200 AMP DETECTORS SHALL RECEIVE PRIMARY POWER FROM THE BUILDING D12 5'-0" 6'-8" 6'-8" 1. A CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH WIRING AND, WHEN POWER IS INTERRUPTED, SHALL RECEIVE POWER SEPARATE SLEEPING AREA IN IMMEDIATE VICINITY OF BEDROOMS D22 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ADDITION FROM A BATTERY. AND ON EACH LEVEL PER 2015 IRC R315. DEMO 2'-0" 6'-8" 6'-8" 2. A SMOKE DETECTOR SHALL BE INSTALLED IN EACH HABITABLE ROOM. INTERCONNECTIVITY R314.4 WHERE MORE THAN ONE SMOKE ALARM IS DEMO 2'-4" 6'-8" 6'-8" 3. A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH REQUIRED TO BE INSTALLED, THE ALARM DEVICES SHALL BE DEMO 5'-0" 6'-8" 6'-8" FLOOR. INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE DEMO 2'-6" 6'-8" 6'-8" 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING DEMO 2'-6" 6'-8" 6'-8" LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL NOT BE THAN 24". REQUIRED WHERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL DEMO 2'-0" 6'-8" 6'-8" 5. SMOKE DETECTORS SHALL BE 110V HARDWIRED, INTERCONNECTED, ALARMS SOUND UPON ACTIVATION OF ONE ALARM. Job No.: 23-15 WITH BATTERY BACKUP, PER 2015 IRC R314. WHERE AN ACCESSORY DWELLING UNIT IS CREATED WITHIN AN EXISTING NOTE: A SPRINKLER SYSTEM IS NOT REQUIRED FOR THIS RESIDENCE. DWELLING UNIT ALL REQUIRED SMOKE ALARMS, IN THE ACCESSORY DWELLING UNIT AND THE PRIMARY DWELLING UNIT, SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL ALARMS IN BOTH THE PRIMARY DWELLING UNIT A2.0 AND THE ACCESSORY DWELLING UNIT DW DN (N) KITCHEN (N) DINING 1 Range Oven (E) MASTER BEDROOM 3 S/CM (N) BATH Refrigerator (N) BEDROOM 3 (N) STORAGE WH (N) GREAT ROOM Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. 4 ALL LIGHTING AND SWITCH LOCATIONS TO BE COORDINATED BETWEEN OWNER, (N) BATHROOM No. GENERAL CONTRACTOR AND ELECTRICIAN, 6 DESIGNER TO BE CONSULTED AS NEEDED EXISTING FURNACE SHOWER/TOILET REMOVE (N) MECH. 2 5 (N) OFFICE (N) BONUS ROOM Issue Date ALL LIGHTING AND SWITCH LOCATIONS (N) BATH TO BE COORDINATED BETWEEN OWNER, GENERAL CONTRACTOR AND ELECTRICIAN, 2 DESIGNER TO BE CONSULTED AS NEEDED (N) BEDROOM 2 Drawn by:Author ELECTRICAL & MECHANICAL 2 BASEMENT MEP A4.0 1/4" = 1'-0" Scale: As indicated DN 1 MAIN LEVEL MEP 1/4" = 1'-0" A4.0 VENTILATION REQUIREMENTS HEATING REQUIREMENTS SPRINKLERS GENERAL ELECTRICAL NOTES MEP KEY NOTES EQUIPMENT BY OTHERS BUILDING DESIGN HEAT LOAD 27,240 BTU/HR NOT APPLICABLE NO. DESCRIPTION IRC M1505 EQUATION 15-1: MAXIMUM HEAT EQUIPMENT OUTPUT 34,050 THIS ELECTRICAL PLAN IS THE ARCHITECT'S SUGGESTED LAYOUT. THE ELECTRICAL CONTRACT 1 VENT HOOD MIN. 100CFM WHOLE HOUSE CONTINUOUS RATE CALCULATION: BTU/HR IS ON A DESIGN-BUILD BASIS. ELECTRICAL CONTRACTOR'S DESIGN SHALL BE APPROVED BY 2 BATHROOM EXHAUST FAN MIN. 50CFM (0.01 X 2213 SQFT) + (7.5 X (3 BEDROOMS+1)) = 52 CFM CONTINUOUS VENTILATION THE OWNER AND SHALL CONFORM TO THE APPLICABLE ELECTRICAL CODE REGARDLESS OF DUCTED HEATPUMP SYSTEM WHAT IS SHOWN IN THIS DRAWING. 3 PANASONIC WHISPER 50/80/110 ON TIMER WHOLE HOUSE INTERMITTENT VENTILATION CALCULATION: BASED ON 12.4 BTU PER SF OF SPACE 4 RHEEM PROTERRA-INTAKE AND EXHAUST TO EXTERIOR ARLINGTON, WA 52CFM X 2 (FACTOR BASED ON 50% RUN TIME)= 102 CFM 50% INTERMITTENT VENTILATION WELL EQUIPMENT ALL SWITCHES, OUTLETSAND ENVIRONMENTAL CONTROLS SHALL BE MOUNTED NOT LESS 5 MITSUBISHI HYPERHEAT HEAT PUMP 309 S DUNHAM AVE THAN 15"NOR MORE THAN 72" ABOVE THE FINISHED FLOOR AND SHALL BE ALIGNED 6 MITSUBISHI AIR HANDLER IN MECH. WHOLE HOUSE VENTILATION PROVIDED BY WHOLE HOUSE FAN VERTICALLY, U.N.O. NOT APPLICABLE ON A TIMER SET TO CONTINUOUS WITH LOCK OUT OR 50% IF INTERMITTENT OPERATION PREFERRED: APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE SECURELY FASTENED IN PLACE. EQUIPMENT = PANASONIC WHISPER FV-0511VK3 50/80/110 CFM WATER HEATERS SHALL BE ANCHORED OR STRAPPED AT POINTS WITHIN THE UPPER 1/3 AND 309 S DUNHAM AVE ADDITION BATHROOM VENTILATION: WATER STORAGE LOWER 1/3 TO RESIST EARTHQUAKE. VENTILATION WHICH WILL PROVIDE AT LEAST 50 CFM VENTILATION LIGHT FIXTURES THAT SERVE TO ILLUMINATE INTERIOR STAIRS SHALL BE LOCATED IN THE CITY WATER IMMEDIATE VICINITY OF EACH STAIR LANDING AND SHALL PROVIDE A MIN. LIGHTING LEVEL OF KITCHEN VENTILATION: 1 FOOT-CANDLE MEASURED AT CENTER OF TREADS AND LANDINGS PER IRC R303.6. EQUIPMENT WILL PROVIDE AT LEAST 100CFM VIA EXTERIOR VENTED HOOD OVER STOVE Job No.: 23-15 A2.1 4" TIGHTLINE TO DRYWELL _______2 1 3 4 5 7 8 9 A4.0 4" / 12" 4" / 12" 2'-0" I DO NOT LOCATE PLUMBING MATCH EXISTING OVERHANG THIS SIDE VENTS IN THE SOLAR READY ZONE 1 _______2 SOLAR READY ZONE 372SF _______4 A4.1 A4.2 ADJUST OVERHANG SO FASCIA IS ABOVE EXISTING ROOF OR TO MATCH EXISTING 15'-9 1/4" RIDGE VENT H G RJ 3 RJ 5'-1 7/8" 2 DS RJ F 3 _______ RJ A4.2 _______3 A4.0 RJ E Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. No. RJ RJ 5 5 RIDGE VENT 2 RIDGE VENT RJ 1 _______ A4.1 DS DS 4" / 12" ROOF PLAN KEY NOTES _______2 4 ROOF PLAN LEGEND A4.2 4" / 12" NO. DESCRIPTION RIDGE VENT RJ 1 SOLAR READY ZONE Issue Date GUTTER (DOUBLE LINE) 2 DOWNSPOUT TO TIGHTLINE TO DRYWELL D 3 30-YEAR ASPHALT ROOF 4" / 12" RIDGE VENT DS DOWNSPOUT LOCATION 4 DOWNSPOUT TO TIGHTLINE TO RAIN GARDEN OR SWALE 5 OVERFRAME OVER EXISTING 4" / 12" SOLAR READY AREA ROOF PER STRUC. C ROOF PLAN OVERFRAME OVER EXISTING ROOF PER STRUC. Drawn by:Author BUILDING OUTLINE RJ ROOF PLAN NOTES RJ RJ DS = DOWNSPOUT (4" SOLID PIPE TIGHTLINED INDEPENDENT OF INSTALL MINIMUM ONE FALL-ARREST BRACKET Scale: FOOTING DRAIN) TO BMP AS NOTED ON SITE PLAN. CENTRALLY LOCATED B As indicated ROOF SYSTEM PER ENGINEER PER IRC 324.6.1 - MIN. (3) 36" PATH AND 18" PATH AT • SHALL HAVE DESIGN DETAILS AND DRAWINGS ON SITE FOR RIDGE 5 FRAMING INSPECTION • SHALL BE INSTALLED AND BRACED PER MANUF. SPECS. 4 RJ RJ RJ A PER IRC AT103.3 - SOLAR READY ZONE MIN. 300 SF (CALC PROVIDED): DS RIDGE VENT RJ 5 ON HOUSE 372SF PROVIDED MATCH EXISTING ROOF 4" / 12" 4" / 12" 10 ATTIC VENTILATION CALCULATIONS: RJ 4 RIDGE VENT = 21.5 SQ. IN. PER LINEAR FT. DS ROOF JACK =38 SQ. IN. EA. BIRD BLOCKING= 3.5 SQ. IN PER LINEAR FT. ADD SOFFIT VENTING AA OR LOW ROOF JACKS AREA 1-ATTIC AREA OVER CONDITIONED= 1356SF TO EXISTING ROOF AREA 1356SF/150 = 9.04 SF REQUIRED MATCH EXISTING ROOF 34LF RIDGE VENT = 34 X 21.5 = 731SQ. IN/144= 5.07 SQ. FT. 16 EA LOW ROOF JACKS = 16 X 38= 608SQ. IN/144= 4.22 SQ. FT. 1 _______ TOTAL PROVIDED = 9.29 SQ. FT. A4.0 AREA 2-VENTED RAFTERS OVER PORCH= 401 SF 2 DUTCH HIP ROOF 401SF/150 = 2.67 SF REQUIRED 6 4" TIGHTLINE TO RAIN GARDEN OR SWALE SEE ELEVATIONS TO MATCH NORTH FACING EXISTING AND 3D FOR ADDITIONAL ROOF STYLE 12LF RIDGE VENT = 12 X 21.5 = 258SQ. IN/144= 1.79 SQ. FT. 28LF BIRD BLOCKING = 28 X 3.5 = 98SQ. IN/144= .68 SQ. FT. MATCH EXISTING ROOFVISUAL INFO ARLINGTON, WA 2 EA LOW ROOF JACKS = 2 X 38= 76SQ. IN/144= .52 SQ. FT. 4" TIGHTLINE TO RAIN GARDEN OR SWALE 309 S DUNHAM AVE TOTAL PROVIDED = 2.99 SQ. FT. 1 WORK - ROOF 1/4" = 1'-0" A4.0 309 S DUNHAM AVE ADDITION Job No.: 23-15 A2.2 1 2 3 4 5 7 8 9 1 2 3 4 5 7 8 9 DEMO EXISTING DECK EXISTING ROOF OVERHANG AND ROOF COVERING TO BE CUT BACK FLUSH TO GRID F SEE DETAIL 1/A4.2 EXISTING WALL COULD REMAIN IN PLACE AND FILL IN DOOR OR REFRAME PER NEW FLOOR PLAN 2'-0" F F 2'-0" E E EXISTING ROOF OVERHANG TO BE CUT BACK FLUSH TO GRID E SEE DETAIL 1/A4.2 1'-6 1/2" WALL TO REMAIN IN PLACE AS BEARING WALL. WILL BE MODIFIED AT ENDS, (E) BEDROOM Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. TEMP 2X4 WALL TO SUPPORT SEE FRAMING PLANS FOR DIMENSIONS (E) KITCHEN ROOF DURING WALL REMOVAL -COULD REFRAME WALL IF DESIRED AND HEADER REPLACEMENT No. BUT PROVIDE TEMPORARY SUPPORT WALL (E) MECHANICAL PRIOR TO REMOVAL OR MODIFICATION REMOVE EXISTING SKYLIGHT STAIR (E) LAUNDRY LEAVE IN PLACE TEMP. REMOVE ON NEW WALL AT BED TO BATH IN PLACE LEAVE IN PLACE TEMP. (E) LIVING ROOM DEMO WALL TO HERE AND REFRAME? LEAVE WALL IN PLACE AS TEMPORARY (E) BATH ROOF SUPPORT UNTIL NEW BEAMS INSTALLED PER STRUC. CONSIDER REFRAME D D DOOR OPENING Issue Date DEMO EXISTING WALLS, NON-BEARING LEAVE IN PLACE TEMP., C REMOVE ONCE NEW WALL AT C LAUNDRY/BATHROOM IN PLACE USE TEMP WALLS AS (E) BONUS ROOM NEEDED FOR HEADER REPLACEMENTS PER Drawn by:Author LEAVE IN PLACE TEMP., REMOVE ONCE NEW WALL BEST PRACTICES DEMOLITION PLAN (E) BEDROOM BETWEEN BED AND BATH IN PLACE FILL IN FRAMING REMOVE HEADER AND WALL (E) DINING (E) BEDROOM 10'-1 5/8" B B Scale: 1/4" = 1'-0" 6 6 A A USE TEMP WALLS AS 10 10 NEEDED FOR HEADER DEMO CONCRETE STAIRS REPLACEMENTS PER SAW CUT CONCRETE AS BEST PRACTICES NECESSARY TO ENSURE CLEAN REMOVAL AA EXISTING ROOF OVERHANG AA TO BE CUT BACK FLUSH TO GRID A 2 BASEMENT DEMOLITION PLAN 1 MAIN LEVEL DEMOLITION PLAN 1/4" = 1'-0" 1/4" = 1'-0" A4.0 A4.0 ARLINGTON, WA 309 S DUNHAM AVE 309 S DUNHAM AVE ADDITION Job No.: 23-15 A3.0 1 2 3 4 5 7 8 9 2 3/4" 2 3/4" I SONOTUBE O/24" BIG FOOT BF24 FOOTING VERIFY WITH STRUC. 28'-0 1/2" 14'-0 1/4" 14'-0 1/4" H 3'-0" G DOWEL AND EPOXY PER STRUC, 11'-4 1/2" 6" STEM WALL ~2' TALL KITCHEN SINK WASTE LINE FOOTING AND NOT DRIVING DIMENSION 15'-0" REBAR PER STRUC. PROPOSED ADDITION MAY NEED KNOCK OUT DRIVING DIMENSION 12'-0" FOR PLUMBING WASTE LINE VENTED CRAWLSPACE FROM KITCHEN TO BASEMENT DOWEL AND EPOXY INSTALL 10 MIL VAPOR PER STRUC. BARRIER OVER GROUND F EXISTING FULL HEIGHT BASEMENT FOUNDATION WALL (E) STEM WALLS 4'-0" (N) STAIR OPENING E FOUNDATION VENT, 5 EA LOCATE WITHIN 3' OF CORNERS Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. No. RECOMMEND INSTALLATION OF INTERIOR FOOTING DRAIN SYSTEM, BY OTHERS TIE INTO SUMP PUMP DISCHARGE SUMP INTO TIGHTLINE TO DRYWELL OR RAIN GARDENS WH 12'-10 1/8" (N) STAIR OPENING GRINDER PUMP LOC. PLUMBER TO VERIFY POSSIBLE SUMP LOCATION CL VANITY ABV. Issue Date D CL TOILET ABV. 7'-9 1/8" (N) STAIR OPENING 7'-0" EXISTING BASEMENT C CL VANITY ABV. CL SHOWER DRAIN ABV. Drawn by:Author 8'-8 1/8" CL WASHER ABV. (N) BONUS ROOM CL TOILET ABV. 3'-4 1/2" FOUNDATION & FRAMING PLAN FOUNDATION PLAN NOTES B Scale: As indicated CL PLUMBING WALL ABV. CRAWLSPACE VENTILATION CALCULATIONS: CL SHOWER DRAIN ABV. 2'-11" 15'-6 1/2" FOUNDATION VENT = 72.5 SQ. IN. PER EA. 16X8 UNIT AREA 1-NEW CRAWLSPACE= 347SF 1'-2" 347SF/150 = 2.31 SF OR 332 SQ. IN. REQUIRED A 5 FOUNDATION VENTS = 5 X 72.5 = 362.5 SQ. IN PROVIDED DROP PLUMBING WASTE FROM ABOVE TO NEW BASEMENT WALL, 10 SAW CUT FROM THIS LOCATION TO GRINDER PUMP LOC. PER PLUMBER PLUMBING WALL AA (VERIFY FIXTURE LOCATION WITH CABINETRY) 1 PLAN NOTE 1 FOUNDATION PLAN 6 SPOT ELEVATION 1/4" = 1'-0" A4.0 ARLINGTON, WA 309 S DUNHAM AVE E E ELECTRIC W W WATER 309 S DUNHAM AVE ADDITION DOWNSPOUT LOCATION DS Job No.: 23-15 A3.1 2 _______ 2 _______ A4.1 A4.1 PROPOSED ADDITION 3 NEW ROOF BEYOND ELEVATION KEY NOTES DUTCH HIP TO MATCH NORTH ELEVATION ROOF STYLE 8 TOP OF RIDGE 191'-10" TOP OF RIDGE 191'-10" NO. DESCRIPTION 1 (N) ASPHALT ROOF 2 WRAP POSTS IN PWW 2 OR 3 EQUAL RISERS IF 3 OR MORE HANDRAIL 3 HARDIE LAP SIDING-8" REVEAL, VERIFY WITH OWNER REQUIRED PER IRC 4" / 12" 1 4 TREX DECK FASCIA 3 3 _______ _______ 5 1X6 PWW TRIM OR HARDIE TRIM A4.2 4" / 12" A4.2 4" / 12" 6 (N) 5" GUTTER 7 TREX DECKING OR EQUIV. TOP PLATE 186'-0 3/4" TOP PLATE 186'-0 3/4" 8 1X10 PWW TRIM OR HARDIE TRIM F14 D1 2 F22 3 F1 F2 F3 F4 F5 F10 F11 F12 F15 F16 F17 D2 2 F13 7'-10 3/4" 7 4 DOOR FRAMING SCHEDULE MAIN LEVEL 178'-2" MAIN LEVEL 178'-2" NO. DOOR SIZE HEAD HEIGHT COMMENTS GRADE 176'-10" GRADE 176'-10" BASEMENT FF D13 2'-6" 6'-8" 6'-8" D14 2'-10" 6'-8" 6'-8" D15 2'-6" 6'-8" 6'-8" D16 2'-4" 6'-8" 6'-8" D17 1'-8" 6'-8" 6'-8" D18 2'-6" 6'-8" 6'-8" D19 2'-6" 6'-8" 6'-8" D20 2'-6" 6'-8" 6'-8" D21 5'-0" 6'-8" 6'-8" BASEMENT FF 170'-0" BASEMENT FF 170'-0" DEMO 2'-6" 6'-8" 6'-8" DEMO 2'-6" 6'-8" 6'-8" MAIN LEVEL 2 EAST ELEVATION 1 WEST ELEVATION D1 3'-0" 6'-8" 6'-8" D2 6'-0" 6'-8" 6'-8" 1/4" = 1'-0" 1/4" = 1'-0" A2.0 A2.0 D3 6'-0" 6'-8" 6'-8" D4 2'-6" 6'-8" 6'-8" D5 2'-8" 6'-8" 6'-8" D6 2'-6" 6'-8" 6'-8" D7 2'-6" 6'-8" 6'-8" D8 2'-6" 6'-8" 6'-8" D9 6'-0" 6'-8" 6'-8" D10 5'-0" 6'-8" 6'-8" PROPOSED ADDITION EXISTING RESIDENCE PROPOSED PORCH ADDITION D11 2'-6" 6'-8" 6'-8" D12 5'-0" 6'-8" 6'-8" D22 2'-6" 6'-8" 6'-8" Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. 4 DEMO 2'-0" 6'-8" 6'-8" _______ A4.2 OVERFRAME NEW ROOF DEMO 2'-4" 6'-8" 6'-8" SIDING TO MATCH ON EXISTING DEMO 5'-0" 6'-8" 6'-8" No. AND NEW ADDITION DEMO 2'-6" 6'-8" 6'-8" REPLACE FASCIA AS NEEDED DEMO 2'-6" 6'-8" 6'-8" DEMO 2'-0" 6'-8" 6'-8" TOP OF RIDGE 191'-10" OVERFRAME NEW ROOF 1 4" / 12" 4" / 12" FRAMING - WINDOW SCH. 6 MARK SIZE (W x H) HEAD HEIGHT REMARKS F1 2'-6"x4'-6" 6'-8" 3" / 12" TOP PLATE 186'-0 3/4" F2 2'-6"x4'-6" 6'-8" F3 2'-0"x3'-6" 6'-6" VENT-FIXED-V ENT Issue Date 15'-0" _______2 F4 4'-0"x3'-6" 6'-6" VENT-FIXED-V A4.2 ENT 2 5 F6 3 F7 F8 F9 F5 2'-0"x3'-6" 6'-6" VENT-FIXED-V ENT 2 OR 3 EQUAL RISERS 7'-10 3/4" F6 2'-6"x4'-6" 7'-0" 7 IF 3 OR MORE HANDRAIL F7 2'-6"x4'-6" 7'-0" VENT-FIXED-V ELEVATIONS 4 4 REQUIRED PER IRC ENT Author Drawn by: F8 2'-6"x4'-6" 7'-0" VENT-FIXED-V ENT MAIN LEVEL 178'-2" F9 2'-6"x4'-6" 7'-0" VENT-FIXED-V ENT GRADE 176'-10" F10 2'-6"x4'-6" 7'-0" VENT-FIXED-V ENT F11 2'-6"x4'-6" 7'-0" VENT-FIXED-V ENT Scale: F12 2'-6"x4'-6" 7'-0" VENT-FIXED-V 1/4" = 1'-0" ENT F13 1'-6"x5'-0" 6'-8" F14 3'-0"x1'-6" 7'-0" VENT-FIXED-V ENT F15 2'-6"x4'-6" 7'-0" VENT-FIXED-V BASEMENT FF 170'-0" ENT F16 2'-6"x4'-6" 7'-0" VENT-FIXED-V ENT F17 2'-6"x4'-6" 7'-0" EGRESS F18 2'-6"x4'-6" 7'-0" FIXED-FIXED 3 NORTH ELEVATION F19 2'-6"x4'-6" 7'-0" FIXED-FIXED A2.0 1/4" = 1'-0" F20 2'-0"x3'-6" 7'-0" F21 2'-6"x4'-6" 7'-0" EGRESS F22 5'-0"x3'-6" 6'-11 1/2" EGRESS F23 3'-0"x3'-0" 6'-8" EGRESS F24 3'-0"x1'-6" 7'-1" F25 3'-0"x1'-6" 7'-1" ARLINGTON, WA 309 S DUNHAM AVE 309 S DUNHAM AVE ADDITION Job No.: 23-15 A4.0 ELEVATION KEY NOTES NO. DESCRIPTION 1 (N) ASPHALT ROOF 4 _______ A4.2 2 WRAP POSTS IN PWW PROPOSED PORCH ADDITION PROPOSED ADDITION 3 HARDIE LAP SIDING-8" REVEAL, VERIFY WITH OWNER 4 TREX DECK FASCIA 5 1X6 PWW TRIM OR HARDIE TRIM 6 (N) 5" GUTTER TOP OF RIDGE 191'-10" 7 TREX DECKING OR EQUIV. 8 1X10 PWW TRIM OR HARDIE TRIM 3" / 12" 4" / 12" 3" / 12" TOP PLATE 186'-0 3/4" 2 _______ DOOR FRAMING SCHEDULE F20 A4.2 F18 F19 F21 NO. DOOR SIZE HEAD HEIGHT COMMENTS D3 BASEMENT FF 7'-10 3/4" D13 2'-6" 6'-8" 6'-8" D14 2'-10" 6'-8" 6'-8" D15 2'-6" 6'-8" 6'-8" D16 2'-4" 6'-8" 6'-8" MAIN LEVEL 178'-2" D17 1'-8" 6'-8" 6'-8" D18 2'-6" 6'-8" 6'-8" GRADE 176'-10" D19 2'-6" 6'-8" 6'-8" D20 2'-6" 6'-8" 6'-8" D21 5'-0" 6'-8" 6'-8" DEMO 2'-6" 6'-8" 6'-8" DEMO 2'-6" 6'-8" 6'-8" MAIN LEVEL D1 3'-0" 6'-8" 6'-8" D2 6'-0" 6'-8" 6'-8" D3 6'-0" 6'-8" 6'-8" BASEMENT FF 170'-0" D4 2'-6" 6'-8" 6'-8" D5 2'-8" 6'-8" 6'-8" D6 2'-6" 6'-8" 6'-8" D7 2'-6" 6'-8" 6'-8" D8 2'-6" 6'-8" 6'-8" D9 6'-0" 6'-8" 6'-8" 1 SOUTH ELEVATION D10 5'-0" 6'-8" 6'-8" A2.0 1/4" = 1'-0" D11 2'-6" 6'-8" 6'-8" D12 5'-0" 6'-8" 6'-8" D22 2'-6" 6'-8" 6'-8" Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. DEMO 2'-0" 6'-8" 6'-8" DEMO 2'-4" 6'-8" 6'-8" DEMO 5'-0" 6'-8" 6'-8" No. DEMO 2'-6" 6'-8" 6'-8" R2-VENTED ROOF OVER UNCONDITIONED: W4-2X6 EXTERIOR WALL R-26: DEMO 2'-6" 6'-8" 6'-8" • 30-YEAR ASPHALT ROOFING • 1/2 GYPSUM DEMO 2'-0" 6'-8" 6'-8" • WRB WATER-30# TAR PAPER • 2X6" DF • 1/2" PLYWOOD SHEATHING • BLOWN IN CELLULOSE OR BATT R-20 • 2X OR LVL RAFTERS PER STRUC. • 1 1/2" ZIP R-SHEATHING R-6 • VENTED RIDGE • SIDING PER OWNER SPEC. • SOFFIT-T AND G PINE OR EQUIV. • EXTERIOR GRADE PAINT OR STAIN FRAMING - WINDOW SCH. MARK SIZE (W x H) HEAD HEIGHT REMARKS I 4 H G F E (N) GLULAM HEADER D C B A AA _______ PER STRUC. F1 2'-6"x4'-6" 6'-8" A4.2 F2 2'-6"x4'-6" 6'-8" INSTALL ROOF JACKS AT F3 2'-0"x3'-6" 6'-6" VENT-FIXED-V OVERFRAMED AREAS CUT VENT HOLES 6" X 6" BETWEEN (E) ATTIC ENT Issue Date AND OVERFRAMED AREAS (N) GLULAM PER F4 4'-0"x3'-6" 6'-6" VENT-FIXED-V STRUC. EXTEND SLOPE OF (E) ROOF TO NEW RIDGE TOP OF RIDGE 191'-10" ENT F5 2'-0"x3'-6" 6'-6" VENT-FIXED-V ENT 2X RAFTERS PER STRUC. F6 2'-6"x4'-6" 7'-0" 4" / 12" F7 2'-6"x4'-6" 7'-0" VENT-FIXED-V ENT Author Drawn by: F8 2'-6"x4'-6" 7'-0" VENT-FIXED-V VAULTED CEILING ENT (E) ATTIC-2X4 RAFTERS, 2X6 CEILING JOISTS F9 2'-6"x4'-6" 7'-0" VENT-FIXED-V TOP PLATE 186'-0 3/4" ENT ELEVATIONS AND SECTIONS W4 F10 2'-6"x4'-6" 7'-0" VENT-FIXED-V ENT 2 _______ 15'-0" F11 2'-6"x4'-6" 7'-0" VENT-FIXED-V (N) COVERED PORCH A4.2 (N) GREAT ROOM ENT Scale: (N) KITCHEN (E) (5) 2X8 BUILT F12 2'-6"x4'-6" 7'-0" VENT-FIXED-V 1/4" = 1'-0" (N) COVERED PORCH UP BEAM ENT 7'-10 3/4" F13 1'-6"x5'-0" 6'-8" 6'-11 1/4" F14 3'-0"x1'-6" 7'-0" VENT-FIXED-V DECK FRAMING PER STRUC. ENT F15 2'-6"x4'-6" 7'-0" VENT-FIXED-V _______1 MAIN LEVEL 178'-2" ENT A4.2 F16 2'-6"x4'-6" 7'-0" VENT-FIXED-V GRADE 176'-10" ENT F17 2'-6"x4'-6" 7'-0" EGRESS (N) VENTED CRAWLSPACE F18 2'-6"x4'-6" 7'-0" FIXED-FIXED F19 2'-6"x4'-6" 7'-0" FIXED-FIXED F20 2'-0"x3'-6" 7'-0" W5 W5 W1 F21 2'-6"x4'-6" 7'-0" EGRESS W6 (N) BEDROOM 3 (N) MECH. (N) OFFICE F22 5'-0"x3'-6" 6'-11 1/2" EGRESS F23 3'-0"x3'-0" 6'-8" EGRESS F24 3'-0"x1'-6" 7'-1" F25 3'-0"x1'-6" 7'-1" BASEMENT FF 170'-0" (N) FOOTING PER STRUC. W5-2x4 BASEMENT WALL: FL2-FLOOR OVER CRAWLSPACE: • NO WATERPROOF COATING ON CONCRETE FL3-FLOOR OVER CONDITIONED: ARLINGTON, WA • FINISH FLOORING PER OWNER SPEC. • 2" RIGID EPS FOAM • FINISH FLOORING PER OWNER SPEC. 309 S DUNHAM AVE • 3/4 T&G FLOOR SHEATHING • 2X4 STUD WALL W/ MINERAL WOOL INSUL. R-15 • 3/4 T&G FLOOR SHEATHING • 11 7/8 TJI • 1/2" GYPSUM • 2X8 ROUGH SAWN FLOOR JOISTS • BATT INSULATION R-30 • NON-PVA WALL PRIMER • 5/8 GYPSUM • VENTED CRAWLSPACE • LOW OR NO VOC LATEX PAINT • 10MIL VAPOR BARRIER OVER GROUND 309 S DUNHAM AVE ADDITION 2 Section 1 1/4" = 1'-0" A2.0 Job No.: 23-15 A4.1 3 4 5 7 _______ 8 A4.2 E 2 4 _______ A4.1 9 8 7 5 3 2 1 MAIN LEVEL 178'-2" GRADE 176'-10" RAFTERS 2" ABOVE BEAM TO ALLOW FOR VENTING 2" 191'-10" TOP OF RIDGE 8'-2" 2X6 WALL OVER BEAM TO UNDERSIDE OF (N) ROOF EXISTING WALL PLATE TO REMAIN CUT VENT _______3 OR BE REMOVED, FIELD FIT OPENINGS IN EXISTING A4.2 OPTIONAL T AND G PINE SOFFIT SHEATHING BETWEEN ATTIC WALL OVER BEAM TO UNDERSIDE OF NEW ROOF BASEMENT FF 170'-0" OVERFRAMED ATTIC AND OVER FRAMED AREAS TO ALLOW 2X6 WALL OVER BEAM TO UNDERSIDE OF (N) ROOF AIR FLOW TO ROOF JACKS AND RIDGE 186'-0 3/4" TOP PLATE R-21 BATT INSULATION CUT BACK (E) RAFTER ENDS FLUSH TO NEW WALL 13'-6" FFE TO TOP OF BEAM ATTIC (E) 2X4 ROOF RAFTER 7'-10 3/4" TOP PLATE 186'-0 3/4" 2 Stair Section 2 1/4" = 1'-0" DIMENSION IS TO TOP 5/8 GYP., TYP. CEILINGS A2.0 OF FLOOR SHEATHING AT GLULAM BEAM PER STRUC. 178'-2" MAIN LEVEL INTERIOR 176'-10" GRADE (N) GLULAM BEAM HEADER PER STRUC. E D 2X PT DECKING PER STRUC. TREX DECKING OR EQUIV. TOP PLATE 186'-0 3/4" Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. 2 _______ 4 Section 2 No. A4.2 1/4" = 1'-0" OPEN TO ABOVE A2.0 PROPOSED KITCHEN OPEN TO STAIRCASE BEYOND RAILING AT 36" A.F.F. MAIN LEVEL 178'-2" GRADE 176'-10" 12'-10 3/8" WINDER Issue Date 8'-2" TREAD (N) FULL HEIGHT WALL (N) HALF WALL BEYOND 5'-3" BEHIND PANTRY CABINETS WINDER TREAD TO LANDING BASEMENT FF 170'-0" Drawn by:Author WALL SECTIONS AND STAIRS Scale: 3 Stair Section 3 MAIN LEVEL 178'-2" As indicated 1/4" = 1'-0" A2.0 (E) 2X8 FLOOR JOISTS EXTEND FOAM TO TOP OF CONCRETE GRADE 176'-10" FL2-FLOOR OVER CRAWLSPACE: • FINISH FLOORING PER OWNER SPEC. W5-2x4 BASEMENT WALL: • 3/4 T&G FLOOR SHEATHING • NO WATERPROOF COATING ON CONCRETE (N) CRAWLSPACE • 11 7/8 TJI 2' CLEARANCE • 2" RIGID EPS FOAM • BATT INSULATION R-30 • 2X4 STUD WALL W/ MINERAL WOOL INSUL. R-15 10 MIL VAPOR BARRIER • VENTED CRAWLSPACE • 1/2" GYPSUM • 10MIL VAPOR BARRIER OVER • NON-PVA WALL PRIMER GROUND • LOW OR NO VOC LATEX PAINT 1 Section 1 - Callout 1 1" = 1'-0" A4.1 309 S DUNHAM AVEARLINGTON, WA 309 S DUNHAM AVE ADDITION Job No.: 23-15 A4.2 Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. No. 1 3D NW Porch Issue Date 3D EXTERIOR Drawn by:Author Scale: ARLINGTON, WA 309 S DUNHAM AVE 309 S DUNHAM AVE ADDITION 2 3D NE Rear Porch Job No.: 23-15 A5.0 Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. No. 1 3D SE Rear Porch Issue Date 3D EXTERIOR Drawn by:Author Scale: ARLINGTON, WA 309 S DUNHAM AVE 309 S DUNHAM AVE ADDITION Job No.: 23-15 A5.1 Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. No. Issue Date 3D INTERIOR Drawn by:Author Scale: 1 3D BIRDSEYE INTERIOR ARLINGTON, WA 309 S DUNHAM AVE 309 S DUNHAM AVE ADDITION Job No.: 23-15 2 3D BIRDSEYE INTERIOR REAR A5.2 1 2 3 4 5 6 7 8 2 3/4" 2 3/4" I SONOTUBE O/24" BIG FOOT BF24 FOOTING VERIFY WITH STRUC. CONFIRMED. CAST 5/8" Ø ANCHOR ROD 6" INTO SONOTUBE TO RECEIVE 28'-0 1/2" SIMPSON ABU66Z POST BASE. 14'-0 1/4" 14'-0 1/4" 24" W X 12" CONCRETE 30" WIDE x 14" DP CONCRETE FOOTIN GWITH (2) #5 FOOTING WITH (3) #5 BOTTOM BOTTOM BARS BARS EACH WAY BELOW POST ABOVE. 11 H S-2.0 NEW CONCRETE STEMWALL 6" THICK 3'-0" WITH #4 BAR TOP AND BOTTOM AND VERTICALS #4 BARS @ 24" OC G SIMPSON STHD14 DOWEL AND EPOXY HOLD DOWN 2'-0" NEW WALL NEW CONCRETE FOOTING 12" 30" SQ x 14" DP CONCRETE FOOTING 11'-4 1/2" WIDE x 6" DP WITH (2) #4 BARS 6" STEM WALL ~2' TALL WITH (3) #5 BOTTOM BARS EACH WAY. TYPICAL AT (3) 16" X 8" D FOOTING BELOW NOT DRIVING DIMENSION 15'-0" BOTTOM OF FOOTING 2'-0" BELOWREBAR PER STRUC. LOCATIONS 12 TOP OF GRADE TO DECREASE EFFECT PROPOSED ADDITION8 DRIVING DIMENSION S-2.0 12'-0"ON ADJACENT BASEMENT WALL S-2.0 VENTED CRAWLSPACE TYPICAL DOWEL AND EPOXY NEW WALL F 1 S-2.0 EXISTING FULL HEIGHT BASEMENT FOUNDATION WALL OLD ADDITION STEM WALLS 1 3'-0" S-2.0 E Copyright 2020 Sno Valley Cottages, LLC All rights reserved. DRILL AND EPOXY 1/2" Ø CAST 5/8" Ø ANCHOR ROD 6" 11 ANCHOR ROD 6" INTO TOP INTO SONOTUBE TO RECEIVE No. Date S-3.0 OF EXISTING CONCRETE SIMPSON ABU66Z POST BASE. WALL. NOT FOR CONSTRUCTION WH 24" SQ x 12" DP CONCRETE CAST 5/8" Ø ANCHOR ROD 6" FOOTING WITH (2) #5 INTO SONOTUBE TO RECEIVE BOTTOM BARS EACH WAY. SIMPSON ABU66Z POST BASE. Issue Date D FOUNDATION PLAN NOTES: 1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0, S-1.1, AND S-1.2. C EXISTING BASEMENT Drawn by:Author 2.CONTRACTOR SHALL LOCATE AND VERIFY THE FOLLOWING WITH OTHERS PRIOR TO POURING CONCRETE: ALL DOOR OPENINGS AND BLOCKOUTS IN FOUNDATION WALLS; DRAINS AND SLOPES; ALL DUCTS, CHASES AND PIPES PER MECHANICAL, PLUMBING AND ELECTRICAL. FOUNDATION & FRAMING PLAN 3.TOP OF SLAB ON GRADE ELEVATION ASSUMED 0’-0”. PROVIDE 6 MIL POLYETHELENE VAPOR BARRIER BELOW SLAB ON GRADE AT INTERIOR SPACES. Scale: B 1/4" = 1'-0" 4.TOP OF WALL TO BE A MILNIMUM OF 8” ABOVE FINISHED GRADE. DAMPROOF WALLS BY OTHERS. 5.ALL FOOTINGS AND SLABS TO BEAR ON COMPETENT NATIVE SOIL AND/OR STRUCTURAL FILL. SUBGRADE PREPARATION, STRUCTURAL FILL, FOOTING DRAINS, AND OTHER A REQUIREMENTS PER GEOTECH REPORT AS NOTED IN THE STRUCTURAL GENERAL NOTES. 6.ALL REINFORCING TO BE GRADE 60. PROVIDE 3” CLEAR COVER FROM BOTTOM OF 9 FOOTING. 7.ALL WOOD EXPOSED TO CONRETE, WEATHER, OR WITHIN 8” OF FINISHED GRADE SHALL BE PRESSURE-TREATED. 8.PROVIDE HOT-DIPPED GALVANAIZED ANCHOR BOLTS AT PRESSURE TREATED SILL PLATES. 9.ADDITIONAL TYPICAL DETAILS NOT CUT ON PLAN PER S-2.0 SHEETS. NOT ALL DETAILS MAY BE APPLICABLE. 1 FOUNDATION PLAN 1/4" = 1'-0" ARLINGTON, WA 309 S DUNHAM AVE VIRTUS STAMP AND SCOPE 309 S DUNHAM AVE ADDITION ENCOMPASSES THE PRIMARY STRUCTURAL ELEMENTS AS SHOWN IN THE REDLINE MARKUPS, ONLY. PROJECT: SMITH REMODEL PROJECT NUMBER: 24081-0106 DATE: 01/16/2025 Job No.: 23-15 DESCRIPTION: FOUNDATION PLAN DRAWN BY: CDA A3.1 _______ - 28'-0 1/2" 14'-0 1/4" 14'-0 1/4" 9 1 - 2 3 4 5 6 7 8 9 _______ --- 1 2 3 4 5 6 7 8 H DIM. TO CL OF POST - _______ I --- G (N)GLULAM BEAM ABV. 39'-1 7/8" COVERED PORCH ADDITION VAULTED CEILING 4/12 SLOPE (N) VENTED CRAWLSPACE (N) FOUNDATION, SEE FDN PLAN GUARDRAILS REQUIRED IF DECK SURFACE MORE THAN 30" ABOVE GRADE - _______ --- WINDER REQUIRED 12'-9 1/4" TO MEET HEADROOM (E) FOUNDATION, SEE FDN PLAN PER CODE-6'-8" MIN. 13'-9 1/4" 14'-3 1/4" NEW ADDITION 9'-4 3/4" 4'-4 1/2" 2'-7 1/4" 4'-7" 4'-7" 2'-6" 4'-1" F DIM. TO F2 F1 FACE OF DIM. TO CONC. 10'-0 3/8" 2'-5 1/2" 6'-8 1/2" 9'-3 3/8" 9'-8 1/8" FACE OF 9'-4 3/4" 4'-4 1/2" D2 CONC. E (E) VENTED CRAWLSPACE H W4 F5 F4 F3 - _______ 3'-0" --- W4 - 4'-0" 2 NEW ADDITION _______ --- = W5 D13 (N) BATH G 4'-3" (N) BEDROOM 3 3'-2 3/4"D21 3'-6" STUD AND SHEAR WALL PLAN NOTES: 5'-10 1/4" DW DN CL. (N) STORAGE 5'-9 1/2"1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0, (N) DINING S-1.1, AND S-1.2. EGRESS REMOVE WINDOW D3 9'-0 1/2" = AND FILL IN WITH 11'-4 1/2" F23 2.LUMBER GRADE PER STRUCTURAL GENERAL NOTES.FRAMING ALIGN NEW FRAMING CONVERT TO EGRESS WINDOW STAIRS: W4 TO CORNER (E) WALL SILL AT +44" A.F.F. MAX. 14RISERS 3'-9 3/4" (N) KITCHEN AT 7" 3.ALL INTERIOR NON-BEARING, NON-STRUCTURAL WALL STUD REQUIREMENTS PER2X4 INTERIOR WALL, TYP. VAULTED CEILING 4/12 SLOPE REMOVE SIDING 13'-3 7/8" WH 1/2" AIR GAP FROM CONCRETE ON EXT. WALL 5'-6 1/4" S LINEN S STRUCTURAL GENERAL NOTES. 12'-0" 2'-0" W3 F22 13'-0 1/8" STAIR OPENING Range D18 D17 D16 5'-10" 3'-6 5/8" 4.UNLESS NOTED OTHERWISE ON PLAN: HEADERS TO BE (2) 2x8, TO BE SUPPORTED BY (1) 7'-8 3/8"TRIMMER AND (1) KING STUD MINIMUM, CONNECTION HEADERS INTO KING STUD WITH (4) FULL HEIGHT WALL F 3'-10" D19 6x6 POST D15 STUB FOR TOTAL 10d END NAILS EACH SIDE. KING STUDS TO BE CONNECTED TOP AND BOTTOM WITH 6'-4 7/8" S/CM 7'-9 1/8" STAIR OPENING FUTURE SINK 1 (E) WIN. COULD REMAIN 24'-0" 3'-11 5/8" GRINDER (4) 10d TOE NAILS, UNLESS NOTED OTHERWISE ON PLAN. (N) MECH. 2'-9 7/8" PUMP STORAGE CL VANITY ABV. ISLAND 10' X 5' S PANTRY (E) MASTER BEDROOM CLOSET 5.ALL TRIMMERS TO BE CONTINUOUS TO FOUNDATION. 7'-10 1/8" D DBL OvenOVEN E 28'-0" ALIGN 8'-1 1/4" D14 CL TOILET ABV. 6x6 POST 6x6 POST 3'-6 5/8" 6.ALL BEAMS, EXCLUDING HEADERS, SHOWN ON FRAMING PLAN SHALL BE SUPPORTED BY (2) ALIGN WALL ON CENTER W/POST - FLUSH INSIDE FACE OF WALL BUNDLED STUDS OR 4X MEMBER, MINIMUM UNLESS NOTED OTHERWISE ON PLAN. ALL_______ 9'-0 5/8" 28'-0" EXISTING BASEMENT OF POST 7'-2" --- (N) SKYLIGHT OVER THE STAIRS TO INSIDE FACE OF BEAM BUNDLED STUDS TO BE CONTINUOUS TO FOUNDATION.(N)GLULAM 2'-0" C BEAM ABV. (E) DOOR OPENING Refrigerator CL SHOWER DRAIN ABV. ALTER AS NEEDED PER DOOR CL VANITY ABV. 7.ALL EXTERIOR WALLS TO BE CONTINUOUSLY SHEATHED PER SHEAR WALL SCHEDULE 8'-10 1/8" W3 LOCATE WITHIN 3' OF PEAK D9 SELECTION F21 F24 W5 D20 11-S3.1 “UNBLOCKED W6”, UNLESS NOTED OTHERWISE ON PLAN. CL WASHER ABV. EGRESS Copyright 2020 Sno Valley Cottages, LLC All rights reserved. (N)6X6 POST-BEARING TO CABINETS/COUNTER 3'-3 1/2" 2'-10 1/4" 4'-0 1/8" 2'-4" 2'-6" (N) OFFICE (N) BONUS ROOM 8.ALL SHEAR WALLS INDICATED ON PLAN TO HAVE (2) BUNDLED STUDS AT WALL ENDS, 4'-0" F6 (N) WALL BELOW TO FTG. 6'-1 3/8" UNLESS NOTED OTHERWISE ON PLAN. HOLD DOWNS ARE AS INDICATED ON PLAN, AND MAY W1 No. Date 9'-4 3/4" F25 2'-1 1/2" CL TOILET ABV. 3'-4 1/2" NOT BE REQUIRED AT SOME WALLS. S (N) BATHROOM 13'-6" TO CL OF (E) BEAM AND POSTS 9.POST BASES AND CAPS, WHERE NECESSARY, ARE INDICATED ON PLAN. D8 CL. = B MATCH CL PLUMBING WALL ABV. DIM. TO = D10 CL SHOWER DRAIN ABV. 2'-11" 10.FABRICATE ALL STEEL COLUMNS -¼” PER FLOOR TO ALLOW FOR WOOD SHRINKAGE. WALL AT +42" A.F.F. D7 FACE OF 15'-8 1/2" W6 66" VANITY 5'-11 1/4" 4'-0" CONC. DN 4'-9" = 5'-4" 15'-11 1/4" TO STAIR OPENING CLOSET 11.WALL ANCHORAGE AND OTHER TYPICAL WALL FRAMING DETAILS PER SHEETS S-3.0 AND3'-10 7/8" = CONFIRM RO WITH POCKET DOOR SPECS 1'-4" MIRROR DIM. ON FIREPLACE CENTER 7'-9 1/8" (2)2X NOT FOR S-3.1. NOT ALL DETAILS MAY BE APPLICABLE.CONSTRUCTIONFIREPLACE D11 3 1/2" D 3'-3 1/2" SHOWER/TOILET A MATCH (N) GREAT ROOM = FLAT CEILING AT 7' 10-3/4" EXISTING RESIDENCE F20 4'-0" 2'-0" MIRROR DIM. ON FIREPLACE CENTER REBUILD FP AT INTERIOR (N)6x6 POST-BEARING TO METAL RAILING 3'-1" 3'-8 1/4"S/CM SHOWER 4'-3 1/2" F7 AT +36" A.F.F. 4' W X 3' D = Issue Date TO CENTER BEAM BELOW C - ON BEAMS ABV. AND STAIR D4 D5 _______ --- S ADD 2' X 2' SKYLIGHT ABOVE F8 7'-6" 9'-0 1/2" 30'-1 3/8" W1 (N) GLULAM BEAM ABV. 42" VANITY 4'-9 7/8" (N) BEDROOM 2 F19 Author F9 4'-2 1/2"4'-2 1/2" 3'-4 1/2"(N) BATH W2 1'-0" Drawn by: D12 5'-0" BENCH/CUBBIES/CABS 9'-7 5/8" B 2 BASEMENT LEVEL 7'-6" W3 F18 1/4" = 1'-0" 6'-2 7/8" 1'-4 3/8"1'-4 3/8" CLOSET F10 F11 F12 1'-3 1/2" 4'-5 1/2"2'-10" 2'-2" 2'-4 1/2" 6'-7 7/8" 6'-7 7/8" 4'-9 7/8" REMODEL/ADDITION FLOOR PLANS 3'-1 3/8" EGRESS Scale: FLOOR PLAN NOTES D1 As indicated SMOKE ALARMS AND HEAT DETECTION A FRAMING: 2X6 EXTERIOR WALLS REQUIRED LOCATIONS R314.3: FRAMING - DOOR SCH. 1'-6" 3'-0" 7'-6" SMOKE ALARMS/CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN: 2X4/6's AT INTERIOR WALLS UNLESS NOTED OTHERWISE 1. IN EACH SLEEPING ROOM OR SLEEPING LOFT NO. DOOR SIZE HEAD HEIGHT COMMENTS F13 F14 F15 F16 F17 FILL IN 2X4 FRAMING 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE BASEMENT FF AT ALL MODIFIED SEE STRUCTURAL NOTES FOR STUD SCHEDULE. VICINITY OF THE BEDROOMS. D13 2'-6" 6'-8" 6'-8" COVERED WINDOW OPENINGS 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING CONCEALED SPACES SHALL BE FIRESTOPPED IN BOTH DIRECTIONS AT BASEMENTS AND HABITABLE ATTICS. D14 2'-10" 6'-8" 6'-8" NEW ADDITION - PORCH 10" ON CENTER AND AT FLOORS. TYPICAL. 4. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET FROM D15 2'-6" 6'-8" 6'-8" _______ --- THE DOOR OR OPENING OF A BATHROOM. D16 2'-4" 6'-8" 6'-8" ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH D17 1'-8" 6'-8" 6'-8" DN HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. THE LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER D18 2'-6" 6'-8" 6'-8" MINIMUM CLEAR OPENING HEIGHT DIMENSION SHALL BE 24". MINIMUM THAN 24". CLEAR OPENING WIDTH DIMENSION SHALL BE 20". SILL HEIGHT SHALL D19 2'-6" 6'-8" 6'-8" NOT BE MORE THAN 44" ABOVE THE FLOOR. ALTERATIONS, REPAIRS AND ADDITIONS R314.2.2 WHERE ALTERATIONS, D20 2'-6" 6'-8" 6'-8" REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHERE ONE OR D21 5'-0" 6'-8" 6'-8" SHOWER COMPARTMENTS AND WALLS AROUND BATHTUBS WITH MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DEMO 2'-6" 6'-8" 6'-8" SHOWERS SHALL BE FINISHED WITH A SMOOTH NON-ABSORBANT DWELLINGS, OR WHERE AN ACCESSORY DWELLING UNIT IS CREATED DEMO 2'-6" 6'-8" 6'-8" SURFACE TO NOT LESS THAN 72" ABOVE THE FLOOR (IRC R307.2). WITHIN AN EXISTING DWELLING UNIT, EACH DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS AS REQUIRED FOR NEW DWELLINGS. MAIN LEVEL ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN D1 3'-0" 6'-8" 6'-8" D2 1 MAIN LEVEL OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM OF 3/4" D2 6'-0" 6'-8" 6'-8" 1/4" = 1'-0" ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D3 6'-0" 6'-8" 6'-8" DOOR AND TRANSFER GRILLE ABOVE DOOR. HEAT DETECTION INTERCONNECTION R314.4.1 HEAT DETECTORS AND HEAT ALARMS SHALL BE CONNECTED TO AN ALARM OR A SMOKE ALARM D4 2'-6" 6'-8" 6'-8" PROVIDE WEATHER RESISTANT FIBER CEMENT WALLBOARD UNDER TUB THAT IS INSTALLED IN THE DWELLING. ALARMS THAT ARE INSTALLED FOR D5 2'-8" 6'-8" 6'-8" AND SHOWER ENCLOSURE MATERIALS TO A HEIGHT OF 70" MINIMUM THIS PURPOSE SHALL BE LOCATED IN A HALLWAY, ROOM, OR OTHER D6 2'-6" 6'-8" 6'-8" ABOVE THE DRAIN INLET. LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION. D7 2'-6" 6'-8" 6'-8" FLOOR PLAN KEY NOTES ARLINGTON, WA D8 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN COMBINATION ALARMS R314.5 COMBINATION SMOKE AND CARBON OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM ? 3/4" MONOXIDE ALARMS MAY BE USED IN PLACE OF SMOKE ALARMS. D9 6'-0" 6'-8" 6'-8" NO. DESCRIPTION ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D10 5'-0" 6'-8" 6'-8" 1 EXISTING SEWER ~5' ABOVE FFE DOOR AND TRANSFER GRILLE ABOVE DOOR. POWER SOURCE R314.6 SMOKE ALARMS, HEAT ALARMS, AND HEAT D11 2'-6" 6'-8" 6'-8" 2 EXISTING ELECTRICAL PANEL-150 AMP, UPGRADE TO 200 AMP DETECTORS SHALL RECEIVE PRIMARY POWER FROM THE BUILDING D12 5'-0" 6'-8" 6'-8" 1. A CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH WIRING AND, WHEN POWER IS INTERRUPTED, SHALL RECEIVE POWER SEPARATE SLEEPING AREA IN IMMEDIATE VICINITY OF BEDROOMS D22 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ADDITION FROM A BATTERY. VIRTUS STAMP AND SCOPE AND ON EACH LEVEL PER 2015 IRC R315. DEMO 2'-0" 6'-8" 6'-8" ENCOMPASSES THE PRIMARY 2. A SMOKE DETECTOR SHALL BE INSTALLED IN EACH HABITABLE ROOM. INTERCONNECTIVITY R314.4 WHERE MORE THAN ONE SMOKE ALARM IS DEMO 2'-4" 6'-8" 6'-8" 3. A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH REQUIRED TO BE INSTALLED, THE ALARM DEVICES SHALL BE DEMO 5'-0" 6'-8" 6'-8" STRUCTURAL ELEMENTS AS SHOWN FLOOR. INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE IN THE REDLINE MARKUPS, ONLY. DEMO 2'-6" 6'-8" 6'-8" 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING DEMO 2'-6" 6'-8" 6'-8" LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL NOT BE PROJECT: SMITH REMODEL PROJECT NUMBER: 24081-0106 THAN 24". REQUIRED WHERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL DEMO 2'-0" 6'-8" 6'-8" 5. SMOKE DETECTORS SHALL BE 110V HARDWIRED, INTERCONNECTED, ALARMS SOUND UPON ACTIVATION OF ONE ALARM. Job No.: 23-15 WITH BATTERY BACKUP, PER 2015 IRC R314. WHERE AN ACCESSORY DWELLING UNIT IS CREATED WITHIN AN EXISTING DATE: 01/16/2025 NOTE: A SPRINKLER SYSTEM IS NOT REQUIRED FOR THIS RESIDENCE. DWELLING UNIT ALL REQUIRED SMOKE ALARMS, IN THE ACCESSORY DWELLING UNIT AND THE PRIMARY DWELLING UNIT, SHALL BE DESCRIPTION: BASEMENT POST PLAN DRAWN BY: CDA INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL ALARMS IN BOTH THE PRIMARY DWELLING UNIT A2.0 AND THE ACCESSORY DWELLING UNIT _______ - 28'-0 1/2" 11 14'-0 1/4" 14'-0 1/4" 9 2 3 5 S-3.2 6 7 9 1 - 4 8 _______ --- 1 2 3 4 5 6 7 8 H DIM. TO CL OF POST - _______ I --- G 6x6 POST 6x6 POST 6x6 POST (N)GLULAM BEAM ABV. 39'-1 7/8" COVERED PORCH ADDITION 12 VAULTED CEILING 4/12 SLOPE (N) FOUNDATION, SEE FDN PLAN GUARDRAILS REQUIRED IF DECK SURFACE (N) VENTED CRAWLSPACE S-3.2 TYPICAL AT NEW MORE THAN 30" ABOVE GRADE - CONSTRUCTION, UNLESS _______ 11 7/8" DP TJI 210 @ 24" OC 11 7/8" DP TJI 210 @ 24" OC NOTED OTHERWISE --- WINDER REQUIRED 12'-9 1/4" TO MEET HEADROOM (E) FOUNDATION, SEE FDN PLAN PER CODE-6'-8" MIN. 13'-9 1/4" 14'-3 1/4" NEW ADDITION 9'-4 3/4" 4'-4 1/2" 2'-7 1/4" 4'-7" 4'-7" 2'-6" 4'-1" GL 5 1/2" x 10 1/2" F DIM. TO F2 F1 NEW WALLS TO BE 2x6 @ 16" FACE OF DIM. TO CONC. 10'-0 3/8" 2'-5 1/2" 6'-8 1/2" 9'-3 3/8" 9'-8 1/8" FACE OF 9'-4 3/4" 4'-4 1/2" D2 OC WITH (3) 8d TOE NAILS TOP 3'-0" CONC. E 6x6 POST AND BOTTOM H (E) VENTED CRAWLSPACE W4 (2) 2x8 HDR F5 F4 F3 - _______ 6x6 POST 3'-0" W6 BLOCKED --- W4 - 4'-0" 2 NEW ADDITION SHEAR WALL _______ --- = W5 D13 (N) BATH G 4'-3" (N) BEDROOM 3 1 3'-2 3/4"D21 3'-6" (2) 2x8 HDR 5'-10 1/4" S-3.2 CL. (N) STORAGE DW DN 5'-9 1/2" 6x6 POST (N) DINING EGRESS REMOVE WINDOW D3 9'-0 1/2" = AND FILL IN WITH 11'-4 1/2" F23 FRAMING ALIGN NEW FRAMING CONVERT TO EGRESS WINDOW STAIRS: SILL AT +44" A.F.F. MAX. 14RISERS2x8 @ 24" OC, MIN W4 TO CORNER (E) WALL (2) 2x8 HDR 3'-9 3/4" (N) KITCHEN AT 7" 2X4 INTERIOR WALL, TYP. VAULTED CEILING 4/12 SLOPE REMOVE SIDING 13'-3 7/8" WH 1/2" AIR GAP FROM CONCRETE ON EXT. WALL 5'-6 1/4" S LINEN S 12'-0" 2'-0" W3 F22 13'-0 1/8" STAIR OPENING Range D18 D17 D16 5'-10" 3'-6 5/8" 4x8 7'-8 3/8" FULL HEIGHT WALL F 3'-10" D19 D15 STUB FOR 6'-4 7/8" S/CM 7'-9 1/8" STAIR OPENING FUTURE SINK 1 (E) WIN. COULD REMAIN 24'-0" 3'-11 5/8" GRINDER (N) MECH. 2'-9 7/8" PUMP W6 BLOCKED STORAGE CL VANITY ABV. ISLAND 10' X 5' S PANTRY (E) MASTER BEDROOM CLOSET SHEAR WALL 7'-10 1/8" D DBL OvenOVEN E 28'-0" ALIGN 8'-1 1/4" D14 CL TOILET ABV. 3'-6 5/8" ALIGN WALL ON CENTER W/POST - (4) 2x4 OR FLUSH INSIDE FACE OF WALL _______ 4x6 POST 9'-0 5/8" 28'-0" EXISTING BASEMENT OF POST 7'-2" --- 4x6 POST (N) SKYLIGHT OVER THE STAIRS TO INSIDE FACE OF BEAM (N)GLULAM C BEAM ABV. 2'-0" SIMPSON DTT2Z HOLD(E) DOOR OPENING Refrigerator CL VANITY ABV. CL SHOWER DRAIN ABV. DOWN ALTER AS NEEDED PER DOOR 8'-10 1/8" W3 LOCATE WITHIN 3' OF PEAK D9 SELECTION F21 F24 W5 D20 CL WASHER ABV. EGRESS Copyright 2020 Sno Valley Cottages, LLC All rights reserved. (N)6X6 POST-BEARING TO CABINETS/COUNTER 3'-3 1/2" 2'-10 1/4" 4'-0 1/8" 2'-4" 2'-6" (N) OFFICE (N) BONUS ROOM 4'-0" F6 (N) WALL BELOW TO FTG. 6'-1 3/8" W1 No. Date 9'-4 3/4" F25 2'-1 1/2" CL TOILET ABV. 3'-4 1/2" S (2) 2x8 HDR (N) BATHROOM 13'-6" TO CL OF (E) BEAM AND POSTS D8 CL. = B MATCH CL PLUMBING WALL ABV. DIM. TO = D10 CL SHOWER DRAIN ABV. 2'-11" WALL AT +42" A.F.F.6x6 POST D7 FACE OF 15'-8 1/2" W6 66" VANITY 5'-11 1/4" 4'-0" CONC. DN 4'-9" = 5'-4" 15'-11 1/4" TO STAIR OPENING CLOSET 3'-10 7/8" 1'-4" MIRROR DIM. ON FIREPLACE CENTER 7'-9 1/8" = CONFIRM RO WITH POCKET DOOR SPECS (2)2X NOT FOR CONSTRUCTIONFIREPLACE D11 3 1/2" D 3'-3 1/2" SHOWER/TOILET A MATCH (N) GREAT ROOM = EXISTING RESIDENCE FLAT CEILING AT 7' 10-3/4"6x6 POST 6x6 POST 4'-0" 2'-0"F20 MIRROR DIM. ON FIREPLACE CENTER REBUILD FP AT INTERIOR (N)6x6 POST-BEARING TO METAL RAILING 3'-1" 3'-8 1/4"S/CM SHOWER 4'-3 1/2" F7 AT +36" A.F.F. 4' W X 3' D = Issue Date TO CENTER BEAM BELOW C - ON BEAMS ABV. AND STAIR D4 D5 _______ --- S ADD 2' X 2' SKYLIGHT ABOVE F8 7'-6" 9'-0 1/2" 30'-1 3/8" W1 (N) GLULAM BEAM ABV. 42" VANITY 4'-9 7/8" (2) 2x12 HDR (N) BEDROOM 2 F19 Author F9 4'-2 1/2"4'-2 1/2" 3'-4 1/2"(N) BATH W2 1'-0" Drawn by: D12 5'-0" BENCH/CUBBIES/CABS 9'-7 5/8" B 2 BASEMENT LEVEL 7'-6" W3 F18 1/4" = 1'-0" 6'-2 7/8" 1'-4 3/8"1'-4 3/8" CLOSET F10 F11 F12 1'-3 1/2" 4'-5 1/2"2'-10" 2'-2" 2'-4 1/2" 6'-7 7/8" 6'-7 7/8" 4'-9 7/8" FLOOR FRAMING PLAN NOTES: STUD AND SHEAR WALL PLAN NOTES: 3'-1 3/8" REMODEL/ADDITION FLOOR PLANS FLOOR PLAN NOTES1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0, 1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0, D1 EGRESS Scale: As indicated SMOKE ALARMS AND HEAT DETECTION S-1.1, AND S-1.2. A S-1.1, AND S-1.2. REQUIRED LOCATIONS R314.3: 1'-6"4x6 POST 3'-0" 7'-6" FRAMING: 2X6 EXTERIOR WALLS FRAMING - DOOR SCH. SMOKE ALARMS/CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN: 2X4/6's AT INTERIOR WALLS 2.LUMBER GRADE PER STRUCTURAL GENERAL NOTES. UNLESS NOTED OTHERWISE2.ALL DUCTS CHASES AND PIPES SHALL BE PER MECHANICAL, PLUMBING, ELECTRICAL AND1. IN EACH SLEEPING ROOM OR SLEEPING LOFT NO. DOOR SIZE HEAD HEIGHT COMMENTS F13 F14 F15 F16 F17 FILL IN 2X4 FRAMING 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE SPRINKLER DRAWINGS. BASEMENT FF AT ALL MODIFIED SEE STRUCTURAL NOTES FOR STUD SCHEDULE. VICINITY OF THE BEDROOMS. D13 2'-6" 6'-8" 3.ALL INTERIOR NON-BEARING, NON-STRUCTURAL WALL STUD REQUIREMENTS PER6'-8" COVERED WINDOW OPENINGS 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING CONCEALED SPACES SHALL BE FIRESTOPPED IN BOTH DIRECTIONS AT 3.23/32 FLOOR SHEATHING PER STUCTURAL GENERAL NOTES. SHEATHING TO BE GLUEDBASEMENTS AND HABITABLE ATTICS. D14 2'-10" 6'-8" STRUCTURAL GENERAL NOTES.6'-8" NEW ADDITION - PORCH 10" ON CENTER AND AT FLOORS. TYPICAL.AND NAILED TO FLOOR FRAMING WITH 8d X 2 ½4. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET FROM” COMMON WIRE NAILS @ 6” OC AT D15 2'-6" 6'-8" 6'-8" _______ --- SUPPORTED PANEL EDGES, AND 12” OC FIELD NAILING. LAY SHEATHING THE LONGTHE DOOR OR OPENING OF A BATHROOM. D16 2'-4" 6'-8" 4.UNLESS NOTED OTHERWISE ON PLAN: HEADERS TO BE (2) 2x8, TO BE SUPPORTED BY (1)6'-8" ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH DIRECTION PERPENDICULAR TO SUPPORTS AND STAGGER PANEL END JOINTS. ALLOW 1/8LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER” D17 1'-8" 6'-8" TRIMMER AND (1) KING STUD MINIMUM, CONNECTION HEADERS INTO KING STUD WITH (4)6'-8" DN HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. THE D18 2'-6" 6'-8" TOTAL 10d END NAILS EACH SIDE. KING STUDS TO BE CONNECTED TOP AND BOTTOM WITH6'-8" MINIMUM CLEAR OPENING HEIGHT DIMENSION SHALL BE 24". MINIMUM SPACE BETWEEN PANEL ENDS AND EDGES. THAN 24". CLEAR OPENING WIDTH DIMENSION SHALL BE 20". SILL HEIGHT SHALL D19 2'-6" 6'-8" (4) 10d TOE NAILS, UNLESS NOTED OTHERWISE ON PLAN.6'-8" NOT BE MORE THAN 44" ABOVE THE FLOOR.4.ALL WOOD EXPOSED TO CONCRETE, WEATHER, OR WITHIN 8ALTERATIONS, REPAIRS AND ADDITIONS R314.2.2 ” OF FINISHED GRADE SHALLWHERE ALTERATIONS, D20 2'-6" 6'-8" 6'-8" REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHERE ONE OR D21 5'-0" 6'-8" 5.ALL TRIMMERS TO BE CONTINUOUS TO FOUNDATION.6'-8" SHOWER COMPARTMENTS BE PRESSURE TREATED.AND WALLS AROUND BATHTUBS WITH MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DEMO 2'-6" 6'-8" 6'-8" SHOWERS SHALL BE FINISHED WITH A SMOOTH NON-ABSORBANT DWELLINGS, OR WHERE AN ACCESSORY DWELLING UNIT IS CREATED SURFACE TO NOT LESS THAN 72" ABOVE THE FLOOR (IRC R307.2). WITHIN AN EXISTING DWELLING UNIT, EACH DWELLING UNIT SHALL BE DEMO 2'-6" 6'-8" 6.ALL BEAMS, EXCLUDING HEADERS, SHOWN ON FRAMING PLAN SHALL BE SUPPORTED BY (2)6'-8" 5.ALL 2X HANGERS TO BE TOP FLANGE BEARING SIMPSON JB TYPE, UNLESS NOTED EQUIPPED WITH SMOKE ALARMS AS REQUIRED FOR NEW DWELLINGS. MAIN LEVEL BUNDLED STUDS OR 4X MEMBER, MINIMUM UNLESS NOTED OTHERWISE ON PLAN. ALL OTHERWISE. ANY HANGERS REQUIRED AT BEAMS ARE SPECIFIED ON PLAN. I JOIST ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN D1 3'-0" 6'-8" BUNDLED STUDS TO BE CONTINUOUS TO FOUNDATION.6'-8" D2 1 MAIN LEVEL OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM OF 3/4"HANGERS TO BE TOP FLANGE BEARING SIMPSON MIT OR ITS TYPE, UNLESS NOTED D2 6'-0" 6'-8" 6'-8" 1/4" = 1'-0" ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDEROTHERWISE. D3 6'-0" 6'-8" 6'-8" DOOR AND TRANSFER GRILLE ABOVE DOOR. HEAT DETECTION INTERCONNECTION R314.4.1 HEAT DETECTORS AND 7.ALL EXTERIOR WALLS TO BE CONTINUOUSLY SHEATHED PER SHEAR WALL SCHEDULE HEAT ALARMS SHALL BE CONNECTED TO AN ALARM OR A SMOKE ALARM D4 2'-6" 6'-8" 6'-8" 6.BEAMS ARE FLUSH FRAMED WITH JOISTS, UNLESS NOTED OTHERWISE ON DETAILS, OR ON 11-S3.1 “UNBLOCKED W6”, UNLESS NOTED OTHERWISE ON PLAN. PROVIDE WEATHER RESISTANT FIBER CEMENT WALLBOARD UNDER TUB THAT IS INSTALLED IN THE DWELLING. ALARMS THAT ARE INSTALLED FOR D5 2'-8" 6'-8" 6'-8" AND SHOWER ENCLOSURE MATERIALS TO A HEIGHT OF 70" MINIMUM PLANS AS “DB.” DB INDICTES A “DROPPED BEAMTHIS PURPOSE SHALL BE LOCATED IN A HALLWAY, ROOM, OR OTHER” WHICH IS FRAMED BELOW THE FLOOR. D6 2'-6" 6'-8" 6'-8" ABOVE THE DRAIN INLET.WHERE BEAMS ARE NOT SUPPORTED BY HANGERS, SUPPORT IS PER THE STUD AND SHEARLOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION. D7 2'-6" 6'-8" 8.ALL SHEAR WALLS INDICATED ON PLAN TO HAVE (2) BUNDLED STUDS AT WALL ENDS,6'-8" ARLINGTON, WA WALL PLAN. PROVIDE A35 CLIPS EA SIDE OF BEAMS THAT BEAR ON DOUBLE TOP PLATES. D8 2'-6" 6'-8" UNLESS NOTED OTHERWISE ON PLAN. HOLD DOWNS ARE AS INDICATED ON PLAN, AND MAY6'-8" FLOOR PLAN KEY NOTES 309 S DUNHAM AVE ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN COMBINATION ALARMS R314.5 COMBINATION SMOKE AND CARBON NOT BE REQUIRED AT SOME WALLS. OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM ? 3/4" MONOXIDE ALARMS MAY BE USED IN PLACE OF SMOKE ALARMS. D9 6'-0" 6'-8" 6'-8" NO. DESCRIPTION ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER 7.WOOD “I-JOISTS” TO BE DESIGNED BY OTHERS. SUBMITTAL INFORMATION, DESIGN D10 5'-0" 6'-8" 6'-8" 1 EXISTING SEWER ~5' ABOVE FFE DOOR AND TRANSFER GRILLE ABOVE DOOR. CRITERIA, RIM JOIST, AND BLOCKING REQUIREMENTS PER STRUCTURAL GENERAL NOTES.POWER SOURCE R314.6 SMOKE ALARMS, HEAT ALARMS, AND HEAT D11 2'-6" 6'-8" 9.POST BASES AND CAPS, WHERE NECESSARY, ARE INDICATED ON PLAN.6'-8" 2 EXISTING ELECTRICAL PANEL-150 AMP, UPGRADE TO 200 AMP DETECTORS SHALL RECEIVE PRIMARY POWER FROM THE BUILDING D12 5'-0" 6'-8" 6'-8" 1. A CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH WIRING AND, WHEN POWER IS INTERRUPTED, SHALL RECEIVE POWER D22 2'-6" 6'-8" 10.FABRICATE ALL STEEL COLUMNS -¼6'-8" ” PER FLOOR TO ALLOW FOR WOOD SHRINKAGE. SEPARATE SLEEPING AREA IN IMMEDIATE VICINITY OF BEDROOMS 8.ALL RIM JOISTS TO BE 1 ½” LSL MINIMUM, UNLESS OTHERWISE NOTED ON PLAN.FROM A BATTERY. VIRTUS STAMP AND SCOPE 309 S DUNHAM AVE ADDITION AND ON EACH LEVEL PER 2015 IRC R315. DEMO 2'-0" 6'-8" 6'-8" ENCOMPASSES THE PRIMARY 2. A SMOKE DETECTOR SHALL BE INSTALLED IN EACH HABITABLE ROOM.9.BEARING STUD, SHEAR WALL, HOLD-DOWN, POST SIZE, AND POST CAP AND BASEINTERCONNECTIVITY R314.4 WHERE MORE THAN ONE SMOKE ALARM IS DEMO 2'-4" 6'-8" 11.WALL ANCHORAGE AND OTHER TYPICAL WALL FRAMING DETAILS PER SHEETS S-3.0 AND6'-8" 3. A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH REQUIREMENTS BELOW PER STUD AND SHEAR WALL PLAN.REQUIRED TO BE INSTALLED, THE ALARM DEVICES SHALL BE DEMO 5'-0" 6'-8" S-3.1. NOT ALL DETAILS MAY BE APPLICABLE.6'-8" STRUCTURAL ELEMENTS AS SHOWN FLOOR. INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE IN THE REDLINE MARKUPS, ONLY. DEMO 2'-6" 6'-8" 6'-8" 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING DEMO 2'-6" 6'-8" 6'-8" LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER 10.FABRICATE ALL STEEL COLUMNS -1/4” PER FLOOR TO ALLOW FOR WOOD SHRINKAGE.UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL NOT BE PROJECT: SMITH REMODEL PROJECT NUMBER: 24081-0106 THAN 24". REQUIRED WHERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL DEMO 2'-0" 6'-8" 6'-8" 5. SMOKE DETECTORS SHALL BE 110V HARDWIRED, INTERCONNECTED, ALARMS SOUND UPON ACTIVATION OF ONE ALARM. 11.TYPICAL DETAILS PER S-3.2. NOT ALL DETAILS MAY BE APPLICABLE. Job No.: 23-15 WITH BATTERY BACKUP, PER 2015 IRC R314. WHERE AN ACCESSORY DWELLING UNIT IS CREATED WITHIN AN EXISTING DATE: 01/16/2025 NOTE: A SPRINKLER SYSTEM IS NOT REQUIRED FOR THIS RESIDENCE. DWELLING UNIT ALL REQUIRED SMOKE ALARMS, IN THE ACCESSORY DWELLING UNIT AND THE PRIMARY DWELLING UNIT, SHALL BE DESCRIPTION: MAIN LEVEL FRAMING, AND MAIN LEVEL STUD DRAWN BY: CDA INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE AND SHEAR WALL PLANS ALARM WILL ACTIVATE ALL ALARMS IN BOTH THE PRIMARY DWELLING UNIT A2.0 AND THE ACCESSORY DWELLING UNIT _______ - 28'-0 1/2" 14'-0 1/4" 14'-0 1/4" 9 1 - 2 3 4 5 6 7 8 9 _______ --- 1 2 3 4 5 6 7 8 H DIM. TO CL OF POST - _______ I --- G (N)GLULAM BEAM ABV. 39'-1 7/8" COVERED PORCH ADDITION VAULTED CEILING 4/12 SLOPE (N) VENTED CRAWLSPACE (N) FOUNDATION, SEE FDN PLAN GUARDRAILS REQUIRED IF DECK SURFACE MORE THAN 30" ABOVE GRADE - _______ --- WINDER REQUIRED 12'-9 1/4" TO MEET HEADROOM (E) FOUNDATION, SEE FDN PLAN PER CODE-6'-8" MIN. 13'-9 1/4" 14'-3 1/4" NEW ADDITION 9'-4 3/4" 4'-4 1/2" 2'-7 1/4" 4'-7" 4'-7" 2'-6" 4'-1" F DIM. TO F2 F1 FACE OF DIM. TO CONC. 10'-0 3/8" 2'-5 1/2" 6'-8 1/2" 9'-3 3/8" 9'-8 1/8" FACE OF 9'-4 3/4" 4'-4 1/2" D2 CONC. E (E) VENTED CRAWLSPACE H W4 F5 F4 F3 - _______ 3'-0" --- W4 - 4'-0" 2 NEW ADDITION _______ --- = W5 D13 (N) BATH G 4'-3" (N) BEDROOM 3 3'-2 3/4"D21 3'-6" 5'-10 1/4" DW DN CL. (N) STORAGE 5'-9 1/2" (N) DINING EGRESS REMOVE WINDOW D3 9'-0 1/2" = AND FILL IN WITH 11'-4 1/2" F23 FRAMING ALIGN NEW FRAMING CONVERT TO EGRESS WINDOW STAIRS: W4 TO CORNER (E) WALL SILL AT +44" A.F.F. MAX. 14RISERS 3'-9 3/4" (N) KITCHEN AT 7" 2X4 INTERIOR WALL, TYP. VAULTED CEILING 4/12 SLOPE REMOVE SIDING 13'-3 7/8" WH 1/2" AIR GAP FROM CONCRETE ON EXT. WALL 5'-6 1/4" S LINEN S 12'-0" 2'-0" W3 F22 13'-0 1/8" STAIR OPENING Range D18 D17 D16 5'-10" 3'-6 5/8" 7'-8 3/8" FULL HEIGHT WALL6x6 ON TOP OF F 3'-10" D19 D15 STUB FOR GLULAM. SIMPSON6'-4 7/8" S/CM 7'-9 1/8" STAIR OPENING FUTURE SINK 1 (E) WIN. COULD REMAIN 24'-0" GRINDER BC60 HALF BASE 3'-11 5/8" (N) MECH. 2'-9 7/8" PUMP STORAGE CL VANITY ABV. ISLAND 10' X 5' S PANTRY (E) MASTER BEDROOM CLOSET 7'-10 1/8" D DBL OvenOVEN E 28'-0" ALIGN 8'-1 1/4" D14 CL TOILET ABV. GL 5 1/2" x 16" 3'-6 5/8" ALIGN WALL ON CENTER W/POST - SIMPSON BA FLUSH INSIDE FACE OF WALL _______ 9'-0 5/8" 28'-0" EXISTING BASEMENT OF POST 7'-2" --- (N) SKYLIGHT OVER THE STAIRS TO INSIDE FACE OF BEAM HANGER (N)GLULAM 2'-0" C BEAM ABV. (E) DOOR OPENING Refrigerator CL SHOWER DRAIN ABV. 4x4 POST ABOVE ALTER AS NEEDED PER DOOR CL VANITY ABV. 2x8 @ 24" OC 8'-10 1/8" WINDOW HEADER W3 LOCATE WITHIN 3' OF PEAK D9 SELECTION F21 F24 W5 D20 SISTERED TO (E) 2x6 CL WASHER ABV. EGRESS Copyright 2020 Sno Valley Cottages, LLC All rights reserved. (N)6X6 POST-BEARING TO CABINETS/COUNTER 3'-3 1/2" 2'-10 1/4" 4'-0 1/8" 2'-4" 2'-6" (N) OFFICE (N) BONUS ROOM 4'-0" F6 (N) WALL BELOW TO FTG. 6'-1 3/8" GL 5 1/2" x 10 1/2" W1 No. Date 9'-4 3/4" F25 6x6 ON TOP OF 2'-1 1/2" CL TOILET ABV. 3'-4 1/2" S GLULAM. SIMPSON (N) BATHROOM 13'-6" TO CL OF (E) BEAM AND POSTS BC60 HALF BASE D8 CL. = B MATCH CL PLUMBING WALL ABV. DIM. TO = D10 CL SHOWER DRAIN ABV. 2'-11" WALL AT +42" A.F.F. D7 FACE OF 15'-8 1/2" W6 SIMPSON HUC 66" VANITY 5'-11 1/4" 4'-0" CONC. DN 4'-9" = 5'-4" 15'-11 1/4" TO STAIR OPENING HANGER CLOSET 3'-10 7/8" 1'-4" MIRROR DIM. ON FIREPLACE CENTER 7'-9 1/8" = CONFIRM RO WITH POCKET DOOR SPECS (2)2X NOT FOR CONSTRUCTIONFIREPLACE D11 4x8 3 1/2" 3'-3 1/2" SHOWER/TOILET D A MATCH (N) GREAT ROOM6x6 ON TOP OF = FLAT CEILING AT 7' 10-3/4" 4x4 POST ABOVEEXISTING RESIDENCE GLULAM. SIMPSON F20 4'-0" 2'-0" WINDOW HEADERMIRROR DIM. ON FIREPLACE CENTER REBUILD FP AT INTERIOR BC60 HALF BASE(N)6x6 POST-BEARING TO METAL RAILING 3'-1" 3'-8 1/4"S/CM SHOWER 4'-3 1/2" F7 AT +36" A.F.F. 4' W X 3' D = Issue Date TO CENTER BEAM BELOW C - ON BEAMS ABV. AND STAIR D4 D5 _______ --- S ADD 2' X 2' SKYLIGHT ABOVE F8 7'-6" 9'-0 1/2" 30'-1 3/8" W1 (N) GLULAM BEAM ABV. 42" VANITY 4'-9 7/8" (N) BEDROOM 2 F19 Author F9 4'-2 1/2"4'-2 1/2" 3'-4 1/2"(N) BATH W2 1'-0" Drawn by: D12 5'-0" BENCH/CUBBIES/CABS 9'-7 5/8" B 2 BASEMENT LEVEL 7'-6" GL 5 1/2" x 10 1/2" W3 F18 1/4" = 1'-0" 6'-2 7/8" 1'-4 3/8"1'-4 3/8" CLOSET F10 F11 F12 1'-3 1/2" 4'-5 1/2"2'-10" 2'-2" 2'-4 1/2" 6'-7 7/8" 6'-7 7/8" 4'-9 7/8" REMODEL/ADDITION FLOOR PLANS 3'-1 3/8" ROOF FRAMING PLAN NOTES: EGRESS Scale: FLOOR PLAN NOTES D1 As indicated SMOKE ALARMS AND HEAT DETECTION 1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0, A FRAMING: 2X6 EXTERIOR WALLS REQUIRED LOCATIONS R314.3: S-1.1, AND S-1.2.FRAMING - DOOR SCH. 1'-6" 3'-0" 7'-6" SMOKE ALARMS/CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN: 2X4/6's AT INTERIOR WALLS UNLESS NOTED OTHERWISE 1. IN EACH SLEEPING ROOM OR SLEEPING LOFT NO. DOOR SIZE HEAD HEIGHT COMMENTS F13 F14 F15 F16 F17 FILL IN 2X4 FRAMING 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE 2.ALL DUCTS CHASES AND PIPES SHALL BE PER MECHANICAL, PLUMBING, ELECTRICAL AND BASEMENT FF AT ALL MODIFIED SEE STRUCTURAL NOTES FOR STUD SCHEDULE. VICINITY OF THE BEDROOMS. D13 2'-6" 6'-8"SPRINKLER DRAWINGS. 6'-8" COVERED WINDOW OPENINGS 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING CONCEALED SPACES SHALL BE FIRESTOPPED IN BOTH DIRECTIONS AT BASEMENTS AND HABITABLE ATTICS. D14 2'-10" 6'-8" 6'-8" NEW ADDITION - PORCH 10" ON CENTER AND AT FLOORS. TYPICAL. 4. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET FROM D15 2'-6" 6'-8"3.ROOF SHEATHING PER PLAN AND STUCTURAL GENERAL NOTES. SHEATHING TO BE NAILED6'-8" _______ --- THE DOOR OR OPENING OF A BATHROOM. D16 2'-4" 6'-8"TO ROOF FRAMING WITH 8d X 2 ½6'-8" ” COMMON WIRE NAILS @ 6” OC AT SUPPORTED PANEL ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH D17 1'-8" 6'-8"EDGES, AND 126'-8" ” OC FIELD NAILING. LAY SHEATHING THE LONG DIRECTION PERPENDICULAR DN HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. THE LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER TO SUPPORTS AND STAGGER PANEL END JOINTS. ALLOW 1/8” SPACE BETWEEN PANEL ENDS D18 2'-6" 6'-8" 6'-8" MINIMUM CLEAR OPENING HEIGHT DIMENSION SHALL BE 24". MINIMUM THAN 24". CLEAR OPENING WIDTH DIMENSION SHALL BE 20". SILL HEIGHT SHALL D19 2'-6" 6'-8"AND EDGES.6'-8" NOT BE MORE THAN 44" ABOVE THE FLOOR. ALTERATIONS, REPAIRS AND ADDITIONS R314.2.2 WHERE ALTERATIONS, D20 2'-6" 6'-8" 6'-8" REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHERE ONE OR D21 5'-0" 6'-8"4.ALL 2X HANGERS TO BE TOP FLANGE BEARING SIMPSON JB TYPE, UNLESS NOTED6'-8" SHOWER COMPARTMENTS AND WALLS AROUND BATHTUBS WITH MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DEMO 2'-6" 6'-8"OTHERWISE. ANY HANGERS REQUIRED AT BEAMS ARE SPECIFIED ON PLAN. I JOIST6'-8" SHOWERS SHALL BE FINISHED WITH A SMOOTH NON-ABSORBANT DWELLINGS, OR WHERE AN ACCESSORY DWELLING UNIT IS CREATED DEMO 2'-6" 6'-8"HANGERS TO BE TOP FLANGE BEARING SIMPSON MIT OR ITS TYPE, UNLESS NOTED6'-8" SURFACE TO NOT LESS THAN 72" ABOVE THE FLOOR (IRC R307.2). WITHIN AN EXISTING DWELLING UNIT, EACH DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS AS REQUIRED FOR NEW DWELLINGS. MAIN LEVEL OTHERWISE. ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN D1 3'-0" 6'-8" 6'-8" D2 1 MAIN LEVEL OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM OF 3/4" D2 6'-0" 6'-8"5.BEAMS ARE FLUSH FRAMED WITH JOISTS, UNLESS NOTED OTHERWISE ON DETAILS, OR ON6'-8" 1/4" = 1'-0" ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER DOOR AND TRANSFER GRILLE ABOVE DOOR. HEAT DETECTION INTERCONNECTION R314.4.1 HEAT DETECTORS AND D3 6'-0" 6'-8"PLANS AS 6'-8"“DB.” DB INDICTES A “DROPPED BEAM” WHICH IS FRAMED BELOW THE FLOOR. HEAT ALARMS SHALL BE CONNECTED TO AN ALARM OR A SMOKE ALARM D4 2'-6" 6'-8"WHERE BEAMS ARE NOT SUPPORTED BY HANGERS, SUPPORT IS PER THE STUD AND SHEAR6'-8" PROVIDE WEATHER RESISTANT FIBER CEMENT WALLBOARD UNDER TUB THAT IS INSTALLED IN THE DWELLING. ALARMS THAT ARE INSTALLED FOR D5 2'-8" 6'-8"WALL PLAN. PROVIDE A35 CLIPS EA SIDE OF BEAMS THAT BEAR ON DOUBLE TOP PLATES.6'-8" AND SHOWER ENCLOSURE MATERIALS TO A HEIGHT OF 70" MINIMUM THIS PURPOSE SHALL BE LOCATED IN A HALLWAY, ROOM, OR OTHER D6 2'-6" 6'-8" 6'-8" ABOVE THE DRAIN INLET. LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION. D7 2'-6" 6'-8"6.PROVIDE SIMPSON STRONG TIE H2.5A TIES AT ALL ROOF TRUSSES6'-8" FLOOR PLAN KEY NOTES ARLINGTON, WA D8 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN COMBINATION ALARMS R314.5 COMBINATION SMOKE AND CARBON OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM ? 3/4" MONOXIDE ALARMS MAY BE USED IN PLACE OF SMOKE ALARMS. D9 6'-0" 6'-8"7.WHERE SHEAR WALLS ARE PERPENDUCLAR TO ROOF TRUSSES, PROVIDE 2X BLOCKING6'-8" NO. DESCRIPTION ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D10 5'-0" 6'-8" 6'-8" 1 EXISTING SEWER ~5' ABOVE FFE BETWEEN ROOF TRUSSES WITH SIMPSON STRONG TIE A35 CLIPS @ 24” OC INTO THE DOOR AND TRANSFER GRILLE ABOVE DOOR. POWER SOURCE R314.6 SMOKE ALARMS, HEAT ALARMS, AND HEAT D11 2'-6" 6'-8" 6'-8" 2 EXISTING ELECTRICAL PANEL-150 AMP, UPGRADE TO 200 AMP DETECTORS SHALL RECEIVE PRIMARY POWER FROM THE BUILDING DOUBLE PLATE. WHERE SHEAR WALLS ARE PARALLEL, ALIGN TRUSS OVER SHEAR WALL, D12 5'-0" 6'-8" 6'-8" 1. A CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH WIRING AND, WHEN POWER IS INTERRUPTED, SHALL RECEIVE POWER AND PROVIDE CONNECTION PER SHEAR WALL SCHEDULE. SEPARATE SLEEPING AREA IN IMMEDIATE VICINITY OF BEDROOMS D22 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ADDITION FROM A BATTERY. VIRTUS STAMP AND SCOPE AND ON EACH LEVEL PER 2015 IRC R315. DEMO 2'-0" 6'-8" 6'-8" 8.ALL RIM JOISTS TO BE 1 ½” LSL MINIMUM, UNLESS OTHERWISE NOTED ON PLAN. ENCOMPASSES THE PRIMARY 2. A SMOKE DETECTOR SHALL BE INSTALLED IN EACH HABITABLE ROOM. INTERCONNECTIVITY R314.4 WHERE MORE THAN ONE SMOKE ALARM IS DEMO 2'-4" 6'-8" 6'-8" 3. A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH REQUIRED TO BE INSTALLED, THE ALARM DEVICES SHALL BE DEMO 5'-0" 6'-8" 6'-8" STRUCTURAL ELEMENTS AS SHOWN FLOOR. INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE DEMO 2'-6" 6'-8"9.ADDITIONAL TYPICAL DETAILS NOT CALLED OUT ON PLAN PER SHEET S-4.0. NOT ALL6'-8" IN THE REDLINE MARKUPS, ONLY. 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING DETAILS MAY BE APPLICABLE. DEMO 2'-6" 6'-8" 6'-8" LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL NOT BE PROJECT: SMITH REMODEL PROJECT NUMBER: 24081-0106 THAN 24". REQUIRED WHERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL DEMO 2'-0" 6'-8" 6'-8" 5. SMOKE DETECTORS SHALL BE 110V HARDWIRED, INTERCONNECTED, ALARMS SOUND UPON ACTIVATION OF ONE ALARM. Job No.: 23-15 WITH BATTERY BACKUP, PER 2015 IRC R314. WHERE AN ACCESSORY DWELLING UNIT IS CREATED WITHIN AN EXISTING DATE: 01/16/2025 NOTE: A SPRINKLER SYSTEM IS NOT REQUIRED FOR THIS RESIDENCE. DWELLING UNIT ALL REQUIRED SMOKE ALARMS, IN THE ACCESSORY DWELLING UNIT AND THE PRIMARY DWELLING UNIT, SHALL BE DESCRIPTION: CEILING SOFFIT FRAMING PLAN DRAWN BY: CDA INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL ALARMS IN BOTH THE PRIMARY DWELLING UNIT A2.0 AND THE ACCESSORY DWELLING UNIT _______ - 28'-0 1/2" 8 14'-0 1/4" 14'-0 1/4" 9 1 - 2 3 4 5 6 7 8 9 S-4.2 _______ --- 1 2 3 4 5 6 7 8 H DIM. TO CL OF POST - _______ I --- G (N)GLULAM BEAM ABV. 39'-1 7/8" COVERED PORCH ADDITION (N) FOUNDATION, SEE FDN PLAN 2x10 @ 24" OCVAULTED CEILING 4/12 SLOPE 2x10 @ 24" OC GUARDRAILS REQUIRED IF DECK SURFACE (N) VENTED CRAWLSPACE MORE THAN 30" ABOVE GRADE - _______ --- WINDER REQUIRED 12'-9 1/4" TO MEET HEADROOM (E) FOUNDATION, SEE FDN PLAN PER CODE-6'-8" MIN. 13'-9 1/4" 14'-3 1/4" NEW ADDITION 9'-4 3/4" 4'-4 1/2" 2'-7 1/4" 4'-7" 4'-7" 2'-6" 4'-1" F (DROPPED) DIM. TO F2 F1 GL 5 1/2" x 10 1/2" FACE OF DIM. TO CONC. 10'-0 3/8" 2'-5 1/2" 6'-8 1/2" 9'-3 3/8" 9'-8 1/8" FACE OF (DROPPED)9'-4 3/4" 4'-4 1/2" D2 CONC. E GL 5 1/2" x 10 1/2" H (E) VENTED CRAWLSPACE W4 F5 F4 F3 - _______ 3'-0" --- W4 - 4'-0" 2 NEW ADDITION _______ --- = W5 D13 (N) BATH 12 G 4'-3" (N) BEDROOM 3 3'-2 3/4"D21 3'-6" 5'-10 1/4" DW S-4.0DN CL. (N) STORAGE 5'-9 1/2" (N) DINING TYPICAL AT NEW EGRESS REMOVE WINDOW CONSTRUCTION, UNLESS D3 9'-0 1/2" F23 = AND FILL IN WITH NOTED OTHERWISE 11'-4 1/2" FRAMING ALIGN NEW FRAMING CONVERT TO EGRESS WINDOW STAIRS: W4 GL 5 1/2" x 10 1/2" RIDGE BEAMTO CORNER (E) WALL SILL AT +44" A.F.F. MAX. 14RISERS 3'-9 3/4" (N) KITCHEN AT 7" 2X4 INTERIOR WALL, TYP. VAULTED CEILING 4/12 SLOPE 6 REMOVE SIDING 13'-3 7/8" WH 1/2" AIR GAP FROM CONCRETE ON EXT. WALL 5'-6 1/4" S LINEN S 12'-0" 2'-0" S-4.0 W3 F22 13'-0 1/8" STAIR OPENING Range D18 D17 D16 5'-10" 3'-6 5/8" 7'-8 3/8" FULL HEIGHT WALL F 3'-10" D19 D15 STUB FOR 6'-4 7/8" S/CM 7'-9 1/8" STAIR OPENING FUTURE SINK 1 (E) WIN. COULD REMAIN 24'-0" 3'-11 5/8" GRINDER (N) MECH. 2'-9 7/8" PUMP STORAGE CL VANITY ABV. ISLAND 10' X 5' S PANTRY (E) MASTER BEDROOM CLOSET 7'-10 1/8" D DBL OvenOVEN E 28'-0" ALIGN 8'-1 1/4" D14 CL TOILET ABV. 3'-6 5/8" ALIGN WALL ON CENTER W/POST - FLUSH INSIDE FACE OF WALL _______ 9'-0 5/8" 28'-0" EXISTING BASEMENT OF POST 7'-2" --- (N) SKYLIGHT OVER THE STAIRS TO INSIDE FACE OF BEAM (N)GLULAM 2'-0" C BEAM ABV. 6'-0" Refrigerator (E) DOOR OPENING CL SHOWER DRAIN ABV. ALTER AS NEEDED PER DOOR CL VANITY ABV. 8'-10 1/8" W3 LOCATE WITHIN 3' OF PEAK D9 SELECTION F21 F24 W5 D20 CL WASHER ABV. GL 5 1/2" x 10 1/2" EGRESS Copyright 2020 Sno Valley Cottages, LLC All rights reserved. (N)6X6 POST-BEARING TO CABINETS/COUNTER 3'-3 1/2" 2'-10 1/4" 4'-0 1/8" 2'-4" 2'-6" (N) OFFICE (N) BONUS ROOM (DROPPED) 4'-0" F6 (N) WALL BELOW TO FTG. 6'-1 3/8" W1 No. Date 9'-4 3/4" F25 2'-1 1/2" CL TOILET ABV. 3'-4 1/2" S 10 (N) BATHROOM 13'-6" TO CL OF (E) BEAM AND POSTS D8 CL. = B S-4.0MATCH CL PLUMBING WALL ABV. DIM. TO = D10 CL SHOWER DRAIN ABV. 2'-11" WALL AT +42" A.F.F. D7 FACE OF 15'-8 1/2" (E) 2x4 @ 24" OC 5'-11 1/4" W6 66" VANITY 4'-0" CONC. DN 4'-9" = 5'-4" 15'-11 1/4" TO STAIR OPENING CLOSET 3'-10 7/8" 1'-4" MIRROR DIM. ON FIREPLACE CENTER 7'-9 1/8" = CONFIRM RO WITH POCKET DOOR SPECS (2)2X NOT FOR CONSTRUCTIONFIREPLACE D11 3 1/2" D 3'-3 1/2" SHOWER/TOILET A MATCH (N) GREAT ROOM = FLAT CEILING AT 7' 10-3/4" EXISTING RESIDENCE F20 4'-0" 2'-0" MIRROR DIM. ON FIREPLACE CENTER REBUILD FP AT INTERIOR (N)6x6 POST-BEARING TO METAL RAILING 3'-1" 3'-8 1/4"S/CM SHOWER 4'-3 1/2" F7 AT +36" A.F.F. 4' W X 3' D = Issue Date TO CENTER BEAM BELOW C - ON BEAMS ABV. AND STAIRGL 5 1/2" x 10 1/2" D4 D5 _______ --- (DROPPED) S ADD 2' X 2' SKYLIGHT ABOVE F8 7'-6" 9'-0 1/2" 30'-1 3/8" 10 W1 (N) GLULAM BEAM ABV. 42" VANITY 4'-9 7/8" S-4.0 6'-0" (N) BEDROOM 2 F19 Author F9 4'-2 1/2"4'-2 1/2" 3'-4 1/2"(N) BATH W2 1'-0" Drawn by: D12 5'-0" (E) 2x4 @ 24" OC BENCH/CUBBIES/CABS 9'-7 5/8" B 2 BASEMENT LEVEL 7'-6" W3 F18 1/4" = 1'-0" 6'-2 7/8" 1'-4 3/8"1'-4 3/8" CLOSET F10 F11 F12 1'-3 1/2" 4'-5 1/2"2'-10" 2'-2" 2'-4 1/2" 6'-7 7/8" 6'-7 7/8" 4'-9 7/8" REMODEL/ADDITION FLOOR PLANS 3'-1 3/8" EGRESS Scale: FLOOR PLAN NOTES D1 As indicated SMOKE ALARMS AND HEAT DETECTION A FRAMING: 2X6 EXTERIOR WALLS REQUIRED LOCATIONS R314.3: FRAMING - DOOR SCH. 1'-6" 3'-0" 7'-6" SMOKE ALARMS/CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN: 2X4/6's AT INTERIOR WALLS UNLESS NOTED OTHERWISE 1. IN EACH SLEEPING ROOM OR SLEEPING LOFT NO. DOOR SIZE HEAD HEIGHT COMMENTS F13 F14 F15 F16 F17 FILL IN 2X4 FRAMING 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE BASEMENT FF AT ALL MODIFIED SEE STRUCTURAL NOTES FOR STUD SCHEDULE. VICINITY OF THE BEDROOMS. D13 2'-6" 6'-8" 6'-8" COVERED WINDOW OPENINGS 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING ROOF FRAMING PLAN NOTES: CONCEALED SPACES SHALL BE FIRESTOPPED IN BOTH DIRECTIONS AT BASEMENTS AND HABITABLE ATTICS. D14 2'-10" 6'-8" 6'-8" NEW ADDITION - PORCH 1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0,_______ 10" ON CENTER AND AT FLOORS. TYPICAL. 4. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET FROM D15 2'-6" 6'-8" 6'-8" --- THE DOOR OR OPENING OF A BATHROOM. D16 2'-4" 6'-8"S-1.1, AND S-1.2.6'-8" ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH D17 1'-8" 6'-8" 6'-8" DN HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. THE LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER 2.ALL DUCTS CHASES AND PIPES SHALL BE PER MECHANICAL, PLUMBING, ELECTRICAL AND D18 2'-6" 6'-8" 6'-8" MINIMUM CLEAR OPENING HEIGHT DIMENSION SHALL BE 24". MINIMUM THAN 24". CLEAR OPENING WIDTH DIMENSION SHALL BE 20". SILL HEIGHT SHALL D19 2'-6" 6'-8"SPRINKLER DRAWINGS. 6'-8" NOT BE MORE THAN 44" ABOVE THE FLOOR. ALTERATIONS, REPAIRS AND ADDITIONS R314.2.2 WHERE ALTERATIONS, D20 2'-6" 6'-8" 6'-8" REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHERE ONE OR D21 5'-0" 6'-8"3.ROOF SHEATHING PER PLAN AND STUCTURAL GENERAL NOTES. SHEATHING TO BE NAILED6'-8" SHOWER COMPARTMENTS AND WALLS AROUND BATHTUBS WITH MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DEMO 2'-6" 6'-8"TO ROOF FRAMING WITH 8d X 2 ½6'-8" ” COMMON WIRE NAILS @ 6” OC AT SUPPORTED PANEL SHOWERS SHALL BE FINISHED WITH A SMOOTH NON-ABSORBANT DWELLINGS, OR WHERE AN ACCESSORY DWELLING UNIT IS CREATED SURFACE TO NOT LESS THAN 72" ABOVE THE FLOOR (IRC R307.2). WITHIN AN EXISTING DWELLING UNIT, EACH DWELLING UNIT SHALL BE DEMO 2'-6" 6'-8"EDGES, AND 126'-8" ” OC FIELD NAILING. LAY SHEATHING THE LONG DIRECTION PERPENDICULAR EQUIPPED WITH SMOKE ALARMS AS REQUIRED FOR NEW DWELLINGS. MAIN LEVELTO SUPPORTS AND STAGGER PANEL END JOINTS. ALLOW 1/8” SPACE BETWEEN PANEL ENDS ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN D1 3'-0" 6'-8"AND EDGES.6'-8" D2 1 MAIN LEVEL OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM OF 3/4" D2 6'-0" 6'-8" 6'-8" 1/4" = 1'-0" ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D3 6'-0" 6'-8"4.ALL 2X HANGERS TO BE TOP FLANGE BEARING SIMPSON JB TYPE, UNLESS NOTED6'-8" DOOR AND TRANSFER GRILLE ABOVE DOOR. HEAT DETECTION INTERCONNECTION R314.4.1 HEAT DETECTORS AND HEAT ALARMS SHALL BE CONNECTED TO AN ALARM OR A SMOKE ALARM D4 2'-6" 6'-8"OTHERWISE. ANY HANGERS REQUIRED AT BEAMS ARE SPECIFIED ON PLAN. I JOIST6'-8" PROVIDE WEATHER RESISTANT FIBER CEMENT WALLBOARD UNDER TUB THAT IS INSTALLED IN THE DWELLING. ALARMS THAT ARE INSTALLED FOR D5 2'-8" 6'-8"HANGERS TO BE TOP FLANGE BEARING SIMPSON MIT OR ITS TYPE, UNLESS NOTED6'-8" AND SHOWER ENCLOSURE MATERIALS TO A HEIGHT OF 70" MINIMUM THIS PURPOSE SHALL BE LOCATED IN A HALLWAY, ROOM, OR OTHER D6 2'-6" 6'-8" 6'-8" ABOVE THE DRAIN INLET. LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION. OTHERWISE. D7 2'-6" 6'-8" 6'-8" FLOOR PLAN KEY NOTES ARLINGTON, WA D8 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN COMBINATION ALARMS R314.5 COMBINATION SMOKE AND CARBON 5.BEAMS ARE FLUSH FRAMED WITH JOISTS, UNLESS NOTED OTHERWISE ON DETAILS, OR ON OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM ? 3/4" MONOXIDE ALARMS MAY BE USED IN PLACE OF SMOKE ALARMS. D9 6'-0" 6'-8" 6'-8" NO. DESCRIPTION PLANS AS “DB.” DB INDICTES A “DROPPED BEAM” WHICH IS FRAMED BELOW THE FLOOR. ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D10 5'-0" 6'-8" 6'-8" 1 EXISTING SEWER ~5' ABOVE FFE DOOR AND TRANSFER GRILLE ABOVE DOOR. POWER SOURCE R314.6 SMOKE ALARMS, HEAT ALARMS, AND HEAT D11 2'-6" 6'-8"WHERE BEAMS ARE NOT SUPPORTED BY HANGERS, SUPPORT IS PER THE STUD AND SHEAR6'-8" 2 EXISTING ELECTRICAL PANEL-150 AMP, UPGRADE TO 200 AMP DETECTORS SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WALL PLAN. PROVIDE A35 CLIPS EA SIDE OF BEAMS THAT BEAR ON DOUBLE TOP PLATES. D12 5'-0" 6'-8" 6'-8" 1. A CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH WIRING AND, WHEN POWER IS INTERRUPTED, SHALL RECEIVE POWER SEPARATE SLEEPING AREA IN IMMEDIATE VICINITY OF BEDROOMS D22 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ADDITION FROM A BATTERY. 6.PROVIDE SIMPSON STRONG TIE H2.5A TIES AT ALL ROOF TRUSSES VIRTUS STAMP AND SCOPE AND ON EACH LEVEL PER 2015 IRC R315. DEMO 2'-0" 6'-8" 6'-8" ENCOMPASSES THE PRIMARY 2. A SMOKE DETECTOR SHALL BE INSTALLED IN EACH HABITABLE ROOM. INTERCONNECTIVITY R314.4 WHERE MORE THAN ONE SMOKE ALARM IS DEMO 2'-4" 6'-8" 6'-8" 3. A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH REQUIRED TO BE INSTALLED, THE ALARM DEVICES SHALL BE DEMO 5'-0" 6'-8"7.WHERE SHEAR WALLS ARE PERPENDUCLAR TO ROOF TRUSSES, PROVIDE 2X BLOCKING6'-8" STRUCTURAL ELEMENTS AS SHOWN FLOOR. INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE DEMO 2'-6" 6'-8"BETWEEN ROOF TRUSSES WITH SIMPSON STRONG TIE A35 CLIPS @ 246'-8" ” OC INTO THE IN THE REDLINE MARKUPS, ONLY. 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING DOUBLE PLATE. WHERE SHEAR WALLS ARE PARALLEL, ALIGN TRUSS OVER SHEAR WALL, DEMO 2'-6" 6'-8" 6'-8" LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL NOT BE PROJECT: SMITH REMODEL PROJECT NUMBER: 24081-0106 THAN 24". REQUIRED WHERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL DEMO 2'-0" 6'-8"AND PROVIDE CONNECTION PER SHEAR WALL SCHEDULE.6'-8" 5. SMOKE DETECTORS SHALL BE 110V HARDWIRED, INTERCONNECTED, ALARMS SOUND UPON ACTIVATION OF ONE ALARM. Job No.: 23-15 WITH BATTERY BACKUP, PER 2015 IRC R314. WHERE AN ACCESSORY DWELLING UNIT IS CREATED WITHIN AN EXISTING 8.ALL RIM JOISTS TO BE 1 ½” LSL MINIMUM, UNLESS OTHERWISE NOTED ON PLAN. DATE: 01/16/2025 NOTE: A SPRINKLER SYSTEM IS NOT REQUIRED FOR THIS RESIDENCE. DWELLING UNIT ALL REQUIRED SMOKE ALARMS, IN THE ACCESSORY DWELLING UNIT AND THE PRIMARY DWELLING UNIT, SHALL BE 9.ADDITIONAL TYPICAL DETAILS NOT CALLED OUT ON PLAN PER SHEET S-4.0. NOT ALL DESCRIPTION: ROOF FRAMING PLAN DRAWN BY: CDA INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL ALARMS IN BOTH THE PRIMARY DWELLING UNIT DETAILS MAY BE APPLICABLE. A2.0 AND THE ACCESSORY DWELLING UNIT GENERAL REQUIREMENTS STRUCTURAL OBSERVATION FILL MATERIAL PENETRATION SLEEVES STRUCTURAL OBSERVATION IS THE VISUAL OBSERVATION OF THE STRUCTURAL COMPACTED FILL MATERIAL SHALL BE PLACED IN MAXIMUM 12" LIFTS AND PROVIDE SLEEVES FOR ALL UTILITY OPENINGS. DO NOT CUT ANY REINFORCING GOVERNING CODE SYSTEM BY A REGISTERED DESIGN PROFESSIONAL FOR GENERAL SHALL BE COMPACTED TO MINIMUM 95% MODIFIED PROCTOR IN ACCORDANCE AT OPENINGS. CONCRETE WHICH HAS CONTAINED WATER FOR MORE THAN 90 THE DESIGN AND CONSTRUCTION OF THIS PROJECT IS GOVERNED BY THE CONFORMANCE TO THE APPROVED CONSTRUCTION DOCUMENTS. PER IBC WITH ASTM D1557. COMPACTION SHALL BE VERIFIED BY A QUALIFIED MINUTES (60 MINUTES IF AIR TEMPERATURE EXCEEDS 85 DEGREES) SHALL NOT INTERNATIONAL BUILDING CODE (IBC) 2021 EDITION, HEREAFTER REFERRED SECTION 1704.6 STRUCTURAL OBSERVATION IS NOT REQUIRED FOR THIS INSPECTOR APPROVED BY THE BUILDING OFFICIAL. BE USED. RETEMPERING OF CONCRETE AFTER INITIAL SET IS NOT ALLOWED. TO AS THE IBC, AS ADOPTED AND MODIFIED BY ARLINGTON, WA UNDERSTOOD PROJECT. HOWEVER, THIS DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY CURE EXPOSED CONCRETE PER ACI 301 FOR A MINIMUM OF 7 DAYS. FOR THE SPECIAL INSPECTIONS AND TESTS REQUIRED BY A SPECIAL INSPECTOR TO BE THE AUTHORITY HAVING JURISDICTION (AHJ). DRAINAGE PER IBC CHAPTER 17. PROVIDE POSITIVE DRAINAGE SLOPES, BOTH DURING AND AFTER CONSTRUCTION JOINTS REFERENCE STANDARDS CONSTRUCTION, FOR SURFACE AND ROOF RUNOFF. CONFORM TO ACI301 SECTION 2.2.2.5, 5.2.2.1, AND 5.3.2.6. SUBMIT LOCATIONS OF AT THE ENGINEERS DISCRETION, SITE OBSERVATIONS MAY STILL BE REFER TO CHAPTER 35 OF THE IBC. WHERE OTHER STANDARDS ARE NOTED IN CONSTRUCTION JOINTS PER ACI301 SECTION 5.1.2.3a FOR REVIEW AND APPROVAL PERFORMED. ONLY SIGNIFICANT STAGES OF CONSTRUCTION IDENTIFIED BY THE THE DRAWINGS, USE THE LATEST EDITION OF THE STANDARD UNLESS A BASEMENT WALLS BY THE STRUCTURAL ENGINEER OF RECORD TWO WEEKS MINIMUM PRIOR TO STRUCTURAL OBSERVER REQUIRE OBSERVATION. FOR REPETITIVE OR SIMILAR SPECIFIC DATE IS INDICATED. REFERENCE TO A SPECIFIC SECTION IN A CODE FORMING. STRUCTURAL ELEMENTS IDENTIFIED AS SIGNIFICANT, ONLY THE FIRST ELEMENT DO NOT BACKFILL AGAINST BASEMENT OR RESTRAINED WALLS UNTIL FRAMING DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE ENTIRE OF A STAGE REQUIRES OBSERVATION UNLESS NOTED OTHERWISE. TO SUPPORT WALL IS PERMANENTLY ATTACHED. DO NOT EXCEED 1'-0" STANDARD. DIFFERENTIAL IN FILL LEVEL ON OPPOSITE SIDES OF FOUNDATION WALLS. EMBEDDED ITEMS POSITION AND SECURE IN PLACE EXPANSION JOINT MATERIAL, ANCHORS AND CONSTRUCTION DOCUMENTS THE STRUCTURAL CONSTRUCTION DOCUMENTS REPRESENT THE FINISHED DESIGN CRITERIA DIVISION OF RESPONSIBILITY OTHER STRUCTURAL AND NON STRUCTURAL EMBEDDED ITEMS BEFORE PLACING CONCRETE. CONTRACTOR SHALL REFER TO MECHANICAL, STRUCTURE. THEY DO NOT INDICATE THE METHOD OR SEQUENCE OF THE STRUCTURAL ENGINEER IS NOT RESPONSIBLE FOR ANY GEOTECHNICAL ELECTRICAL, PLUMBING AND ARCHITECTURAL DRAWINGS AND COORDINATE CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND PROVIDE 1. BUILDING RISK CATEGORY II. ASPECTS OF THIS PROJECT. IT IS RECOMMENDED THAT THE OWNER RETAIN A OTHER EMBEDDED ITEMS. ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING REGISTERED GEOTECHNICAL ENGINEER TO CONDUCT A GEOTECHNICAL CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, 2. FLOOR LIVE LOAD = 40 PSF (REDUCIBLE). INVESTIGATION AND PREPARE A REPORT WITH RECOMMENDATIONS FOR BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. THE FOUNDATION DESIGN AND EARTHWORK PROCEDURES. GROUT STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S USE 7000 PSI NOON SHRINK GROUT UNDER COLUMN BASE PLATES. 3. ROOF LIVE LOAD = 20 PSF MEANS, METHODS, TECHNIQUES, SEQUENCES FOR PROCEDURE OF EXTERIOR SLABS AND SIDEWALKS CONSTRUCTION, OR THE SAFETY PRECAUTIONS AND THE PROGRAMS INCIDENT SEE ARCHITECTURAL/CIVIL DRAWINGS FOR EXTERIOR SLABS AND SIDEWALKS. BONDING AGENT THERETO (NOR SHALL OBSERVATION VISITS TO THE SITE INCLUDE INSPECTION 4.SUPERIMPOSED DEAD LOAD ON ROOF JOISTS = 20 PSF USE MATEREMACO ADH326. APPLY IN ACCORDANCE WITH MANUFACTURER OF THESE ITEMS). THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN INSTRUCTIONS. AND IMPLEMENTATION OF ALL SCAFFOLDING, BRACING AND SHORING. 5. GROUND SNOW LOAD = 25 PSF, Ce=1.0, Is=1.0, Ct=1.2, C = 1.0 FLAT ROOF SNOW S LOAD = 21 PSF. SLOPED ROOF SNOW LOAD = 21 PSF CONCRETE CONSTRUCTION MATERIAL STORAGE CONCRETE CRACK REPAIR AND MAINTENANCE PROGRAM CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONCRETE SHRINKS AND CONTINUES TO SHRINK FOR UP TO TWO YEARS AFTER 6. ULTIMATE WIND SPEED = 98 MPH (3-SECOND GUST), RISK CATEGORY II, STANDARDS CONSTRUCTION. LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE CONSTRUCTION AND AS A RESULT, CRACKING WILL TYPICALLY OCCUR. THESE FOOT. EXPOSURE C, GCpi=+/-0.55, Ke = 0.99, G = 0.85, Kzt = 1.0 ACI301-10 “SPECIFICATION FOR STRUCTURAL CONCRETE” CRACKS TO NOT TYPICALLY IMPAIR THE INTEGRITY OF THE STRUCTURE. IBC CHAPTER 19 “CONCRETE” HOWEVER, VIRTUS RECOMMENDS A ONE-TIME CRACK REPAIR AND CONTRACTOR OPTIONS COMPONENT AND CLADDING PRESSURES: ACI318-19 “BUILDING CODE REQUIREMENT FOR STRUCTURAL CONCRETE” MAINTENANCE PROGRAM BE IMPLEMENTED FOR THOSE SLABS EXPOSED TO OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS CHOSEN, THE ACI117-10 “SPECIFICATIONS FOR TOLERANCE FOR CONCRETE CONSTRUCTION WATER OR CHEMICALS. THE MAINTENANCE PROGRAM SHALL CONSIST OF: CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES AND AND MATERIALS” · INSPECT SLABS AND SUPPORTING MEMBERS TWO YEARS AFTER SHALL COORDINATE ALL DETAILS WITH ALL TRADES. CONSTRUCTION MIX DESIGN: · DETERMINE CRACKS IN THE STRUCTURE TO BE REPAIRED NOTE PRIORITIES · REPAIR CRACKS NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. FOR THE TOTAL LENGTH OF CRACKING CAN BE ESTIMATE AT 0.009 FEET OF CRACKS BIDDING PURPOSES, WHERE ANY MEMBER IS SHOWN BUT NOT CALLED OUT, THE PER SQUARE FEET OF SLAB AREA. THE OWNER SHOULD RESERVE FUNDS FOR LARGEST SIMILAR MEMBER SHALL BE UTILIZED. THIS ONE TIME MAINTENANCE PROGRAM, WHICH IS TO TAKE PLACE TWO YEARS AFTER THE COMPLETION OF CONSTRUCTION. DIMENSIONS THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL EVEN THOUGH CRACKING IS NORMAL AND MOST OFTEN NOT STRUCTURAL DIMENSIONS WITH ARCHITECTURAL OR HOME DESIGNER DRAWINGS PRIOR TO SIGNIFICANT, WHEN CRACKING OCCURS DURING CONSTRUCTION THE START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ARCHITECT CONTRACTOR SHALL CONTAC THE ARCHITECT/ENGINEER FOR REVIEW. THE OR ENGINEER OF RECORD. DO NOT USE SCALED DIMENSIONS. CONTRACTOR SHOULD BUDGET 0.004 FT OF EPOXY INJECTED CRACK REPAIR PER 309 S DUNHAM AVE SQUARE FOOT OF SLAB. ARLINGTON, WA 98223 DETAIL CALLOUTS ALL DETAILS SHALL BE INCORPORATED INTO THE PROJECT AT ALL STRENGTH TESTING AND ACCEPTANCE APPROPRIATE LOCATIONS, WHETHER SPECIFICALLY CUT OR NOT. TYPICAL NOTES ON MIX DESIGN TABLE TESTING: OBTAIN SAMPLES AND CONDUCT TESTS IN ACCORDANCE WITH ACI301 DETAILS MAY NOT NECESSARILY BE CUT ON PLANS, BUT APPLY UNLESS NOTED 1. CONFORM TO ACI 301 SECTION 4, AND 4.2.1. SECTION 1.6.3.2. ADDITIONAL SAMPLES MAY BE REQUIRED TO OBTAIN OTHERWISE. FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING 2. W/C RATIO SHALL BE BASED ON THE TOTAL WEIGHT OF CEMENTITIOUS CONCRETE STRENGTHS AT ALTERNATE INTERVALS THAN SHOWN BELOW: CONDITION. MATERIALS. MAXIMUM RATIOS ARE CONTROLLED BY STRENGTH NOTED IN TH ETABLE ABOVE, AND DURABILITY REQUIREMENTS IN ACI318 SECTION 19.3. DRAWING DISCREPANCIES CURE (4) CYLINDERS FOR 28-DAY TEST AGE. TEST (1) CYLINDER AT 7 DAYS, TEST 3. CEMENTITIOUS MATERIALS: WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL 2 CYLINDERS AT 28 DAYS AND HOLD 1 CYLINDER IN RESERVE FOR USE AS THE STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS a. THE USE OF FLY ASH, OTHER POZZOLANS, SILICA FUME, OR SLAG SHALL ENGINEER DIRECTS. AFTER 56 DAYS UNLESS NOTIFIED BY THE ENGINEER TO THE SHALL GOVERN. CONFORM TO ACI318 SECTIONS 1903.2 AND 26.4.2.2. MAXIMUM AMOUNT CONTRARY, THE RESERVE CYLINDER MAY BE DISCARDED WITHOUT BEING SMITH REMODEL OF FLY ASH SHALL BE 25% OF TOTAL CEMENTITIOUS CONTENT UNLESS TESTED FOR SPECIMENS MEETING 28-DAY STRENGTH REQUIREMENTS. REVIEWED AND APPROVED OTHERWISE BY STRUCTURAL ENGINEER OF SPECIALTY ENGINEERING RECORD. ANY ENGINEERING DESIGN, PROVIDED BY OTHERS AND SUBMITTED FOR THE NUMBER OF CYLINDERS INDICATED ABOVE REFERENCE 6 BY 12 INCH b.CEMENTITIOUS MATERIALS SHALL CONFORM TO THE RELEVANT ASTM REVIEW, SHALL BEAR THE SEAL OF AN ENGINEER REGISTERED IN THE STATE OF CYLINDER. IF 4 BY 8 CYLINDERS ARE TO BE USED, ADDITIONAL CYLINDERS STANDARDS LISTED IN ACI318 SECTION 26.4.1.1.1 (a). WASHINGTON. THIS IS TO INCLUDE, BUT NOT BE LIMITED TO BRACING AND 7.SEISMIC DESIGN CATEGORY D, SOILS SITE CLASS D, RISK CATEGORY II, Ie=1.0, MUST BE CURED FOR TESTING OF 3 CYLINDERS AT TEST AGE PER THE TABLE OF SHORING WHETHER TEMPORARY OR PERMANENT. 4. AIR CONTENT TO CONFORM TO ACI318 SECTION 19.3.3.1. MINIMUM MIX DESIGN REQUIREMENTS. Ss=1.034g, S1=0.369g, SDs=0.749g STANDARDS FOR EXPOSURE CLASS ARE NOTED IN THE TABLE ABOVE. IF OTHER DRAWINGS FREEZING AND THAWING CLASS IS NOT NOTED, AIR CONTENT GIEN IS THAT ACCEPTANCE: STRENGTH IS SATISFACTORY WHEN THE FOLLOWING CONDITIONS REFER TO THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, CIVIL AND REQUIRED BY THE STRUCTURAL ENGINEER OR RECORD. TOLERANCE IS +/- 1 ARE MET: PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION INCLUDING BUT NOT SOILS AND FOUNDATIONS 1/2%. AIR CONTENT SHALL BE MEASURED AT POINT OF PLACEMENT. · THE AVERAGE OF ALL SETS OF 3 CONSECUTIVE TESTS EQUAL OR EXCEED LIMITED TO: DIMENSIONS, ELEVATIONS, SLOPES, DOOR AND WINDOW OPENINGS, 5. AGGREGATES SHALL CONFORM TO ASTM C33 THE SPECIFIED STRENGTH. NON-BEARING WALLS, STAIRS, FINISHES, DRAINS, WATERPROOFING, RAILINGS, 6.SLUMP: CONFORM TO ACI 301 SECTION 4.2.2.2. SLUMP SHALL BE DETERMINED CURBS DEPRESSIONS, MECHANICAL UNIT LOCATIONS, AND OTHER SOILS REPORT · NO INDIVIDUAL TEST FALLS BELOW THE SPECIFIED STRENGTH BY MORE AT POINT OF PLACEMENT. NO SOILS REPORT WAS PROVIDED FOR THIS PROJECT. CONFORM TO IBC THAN 500 PSI. NONSTRUCTURAL ITEMS. 7. CHLORIDE CONTENT: CONFORM TO ACI318 TABLE 19.3.2.1 CHAPTER 18. THE FOLLOWING DESIGN SOIL VALUES HAVE BEEN ASSUMED IN DESIGN OF THESE DOCUMENTS. SPREAD FOOTINGS SHALL BEAR ON COMPETENT 8. EXPOSURE CLASS IS ASSUMED TO BE F0, S0, W0, AND C0 UNLESS DIFFERENT COORDINATION EXPOSURE IS INDICATED IN THE ABOVE TABLE. CONCRETE PLACEMENT TOLERANCE PERMIT 01/16/2025 NATIVE SOIL OR COMPACTED FILL MATERIAL. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING DETAILS AND CONFORM TO ACI117-10 FOR CONCRETE PLACEMENT TOLERANCE. ACCURACY OF THE WORK; FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR DESIGN SOIL VALUES FLY ASH TECHNIQUES OF ASSEMBLY, AND FOR PERFORMING WORK IN A SAFE AND ALLOWABLE FOUNDATION BEARING PRESSURE 1500 PSF (TOTAL LOAD) NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK OR ARCHITECTURALLY SECURE MANNER. ACTIVE LATERAL PRESSURE 45 PSF/FT EXPOSED CONCRETE. FLY ASH (IF PERMITTED BY ARCHITECTURAL REINFORCING STEEL SPECIFICATIONS) SHALL CONFORM TO ASTM C618, CLASS F AND SHALL BE STANDARDS AT REST RESISTING PRESSURE 250 PSF/FT MEANS METHODS AND SAFETY REQUIREMENTS LIMITED TO 18% OF CEMENTITIOUS MATERIALS AND SHALL HAVE A COEFFICIENT OF FRICTION 0.3 ACI 301-10 “STANDARD SPECIFICATION FOR STRUCTURAL CONCRETE.” THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. CONCRETE SECTION 3 “REINFORCEMENT AND REINFORCEMENT SUPPORTS” CONSTRUCTION AND ALL JOB RELATED SAFETY STANDARDS SUCH AS OSHA. FACTOR OF SAFETY 1.5 SHALL BE FREE OF CHLORIDE. MAXIMUM SLUMP 4 1/2" FOR CONCRETE WITHOUT ACI SP-66(04) “ACI DETAILING MANUAL” THE CONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS OF *IT IS ASSUMED THAT ALL WORK IS PERFORMED ABOVE THE GROUND WATER PLASTICIZER. IF PLASTICIZER IS USED, AN 8" MAXIMUM SLUMP IS ALLOWED AT TH CONSTRUCTION RELATED TO THE INTERMEDIATE STRUCTURAL CONDITIONS. TABLE. PLACEMENT. ALL MIX DESIGNS SHALL BE DESIGNED BY THE CONCRETE CRSE MSP-09 28 EDITION “MANUAL OF STANDARD PRACTICE” PRODUCTION FACILITY IN ACCORDANCE WITH ACI 301 AND SHALL BE REVIEWED IBC CHAPTER 19 “CONCRETE” ALTERNATES FROST DEPTH BY THE STRUCTURAL ENGINEER PRIOR TO PLACEMENT. MIX DESIGNS FOR ACI 318-14 “BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE” ALTERNATE PRODUCTS OF SIMILAR STRENGTH, NATURE, AND FORM FOR FOOTINGS SHALL, AT A MINIMUM, EXTEND BELOW THE ESTABLISHED FROST POST-TENSIONING CONCRETE SHALL BE PROPORTIONED SO AS TO MINIMIZE ACI 117-10 “SPECIFICATIONS FOR TOLERANCES FOR CONCRETE SPECIFIED ITEMS MAY BE SUBMITTED WITH ADEQUATE TECHNICAL DEPTH OF 24”. INTERIOR FOOTINGS, FOOTINGS THAT DO NOT SUPPORT A WALL SHRINKAGE CRACKING. CONSTRUCTION AND MATERIALS” DOCUMENTATION TO THE ARCHITECT/ENGINEER FOR REVIEW. ALTERNATE EXPOSED TO THE EXTERIOR, OR WITHIN 3 FEET OF SUCH A WALL, NEED ONLY MATERIALS THAT ARE SUBMITTED WITHOUT ADEQUATE TECHNICAL EXTEND 12” BELOW THE FINISHED GRADE. VIBRATION DOCUMENTATION OR THAT SIGNIFICANTLY DEVIATE FROM THE DESIGN INTENT MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS OF MATERIALS SPECIFIED MAY BE RETURNED WITHOUT A REVIEW. MATERIALS ON GRADE NEED BE VIBRATED ONLY AROUND UNDER-FLOOR DUCTS, ETC. DO ALTERNATES THAT REQUIRE SUBSTANTIAL EFFORT TO REVIEW WILL NOT BE REINFORCING BARS ASTM A615 GRADE 60 DEFORMED BARS NOT DROP CONCRETE MORE THAN FIVE FEET WITH OUT THE USE OF TREMIES. REVIEWED UNLESS AUTHORIZED BY THE OWNER. REVIBRATE TOPS OF CAISSONS 15 MINUTES AFTER PLACING CONCRETE. BAR SUPPORTS CRSI MSP-09 CHAPTER 3 (BAR SUPPORTS) 24081-0106 TIE WIRE 16 GAGE OR HEAVIER, BLACK ANNEALED CONTROL JOINTS HEADED DEFORMED BARS ASTM A970 S-1.0 01/16/2025 UNLESS APPROVED OTHERWISE IN WRITING BY THE ARCHITECT, ALL CONCRETE GENERAL SLABS ON GRADE SHALL BE BOUND BY CONTROL JOINTS (KEYED OR SAW CUT). NOTES NTS KEYED CONTROL JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING POURING, ALL OTHER JOINTS MAY BE SAW CUT. PLACEMENT STRUCTURAL STEEL PROTECTIVE COATING REQUIREMENTS SHEATHING ACCURATELY PLACE OR SUPPORT ALL REINFORCING, INCLUDING WELDED WIRE SHOP PAINTING SHALL CONFORM TO AISC 360 SECTION M3 AND AISC 303 SECTION WOOD APA-RATED STRUCTURAL SHEATHING INCLUDES ALL VENEER PLYWOOD, STANDARDS FABRIC, WITH GALVANIZED METAL CHAIRS. CONFORM TO ACI 301 SECTION 3.3.2. 6.5 UNLESS OTHERWISE SPECIFIED BY THE PROJECT SPECIFICATIONS. WAFER-BOARD, PARTICLEBOARD, T1-11 SIDING, AND COMPOSITES OF VENEER IBC CHAPTER 22 “STEEL” SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. AND WOOD BASED MATERIAL WITH TONGUE AND GROOVE JOINT. PER ANSI/AISC 303-10 “CODE OF STANDARD PRACTICE FOR STEEL BUILDING AND INTERIOR STEEL NEED NOT BE PAINTED IF THE STEEL SURFACES MEET ANY OF ARCHITECTURAL AND OWNER DIRECTION, NO OSB IS TO BE USED ON THIS FABRICATION BRIDGES” THE FOLLOWING CONDITIONS: PROJECT. CONFIRM WITH ARCHITECT. CONFORM TO “CONSTRUCTION AND TH AISC “MANUAL OF STEEL CONSTRUCTION, 14 EDITION” INDUSTRIAL PLYWOOD” BASED ON PRODUCT STANDARD PS 1-09 BY THE US CONFORM TO ACI 301 SECTION 3.2.2, AND ACI SP-66. · CONCEALED BY THE INTERIOR BUILDING FINISHES AWS D1.1 “STRUCTURAL WELDING CODE - STEEL” DEPARTMENT OF COMMERCE AND “PERFORMANCE STANDARD FOR WOOD · FIREPROOFED 2009 RCSC “SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH STRENGTH BASED STRUCTURAL USE PANELS” BASED ON PRODUCT STANDARD PS 2-10 BY CONCRETE COVER BOLTS” · EMBEDDED IN CONCRETE THE US DEPARTMENT OF COMMERCE AND “PLYWOOD DESIGN SPECIFICATION” CONFORM TO THE FOLLOWING COVE REQUIREMENTS UNLESS NOTED · WELDED; IF AREA REQUIRES PAINTING, DO NOT PAINT UNTIL AFTER WELD BASED ON APA D510C-12 BY THE AMERICAN PLYWOOD ASSOCIATION. UNLESS OTHERWISE IN THE DRAWINGS: INSPECTIONS AND NON-DESTRUCTIVE TESTING REQUIREMENT, IF ANY, ARE NOTED OTHERWISE, SHEATHING SHALL COMPLY WITH THE FOLLOWING TABLE: MATERIALS CONCRETE CAST AGAINST EARTH 3” SATISFIED. WIDE FLANGE (W) SHAPES ASTM A992 Fy=50 KSI CONCRETE PERMANENTLY EXPOSED TO EARTH OR WEATHER 2” · INTERIOR STEEL, EXPOSED TO VIEW, SHALL BE PAINTED WITH ONE COAT OF TIES IN PLINTHS 1 1/2” ANGLE (L) SHAPES ASTM A36 Fy=36 KSI SHOP PRIMER UNLESS OTHERWISE INDICATED IN THE PROJECT STRUCTURAL PLATE (PL) ASTM A36 Fy=36 KSI SPECIFICATIONS. FIELD TOUCH-UPS TO MATCH THE FINISH COAT OR AS BARS EXPOSED TO INTERIOR CONDITIONS ONLY 1” HOLLOW STRUCTURAL SECTION (HSS) AST A500 GRADE B Fy=46 KSI OTHERWISE INDICATED IN THE PROJECT SPECIFICATIONS. HIGH STRENGTH BOLTS ASTM A325/F1852, TYPE 1 OR 3 SPLICES HEAVY HEX NUTS ASTM A563 PER RCSC TABLE 2.1 EXPOSED EXTERIOR STEEL SHALL BE PROTECTED BY ONE OF TWO WAYS. PAINT CONFORM TO ACI 301 SECTION 3.3.2.7. REFER TO TYPICAL LAP SPLICE AND WASHERS ASTM F436 PER RCSC TABLE 2.1 WITH AN EXTERIOR MULTI-COAT SYSTEM AS PER THE PROJECT SPECIFICATIONS, DEVELOPMENT LENGTH SCHEDULE FOR TYPICAL REINFORCEMENT SPLICES. OR BY GALVANIZING. ALL STEEL ELEMENTS NO PROTECTED WITH A PAINT SPLICED INDICATED ON INDIVIDUAL SHEETS SHALL CONTROL OVER THE ANCHOR RODS/BOLTS ASTM 1554 GR. 36 TIMBER CONNECTORS SYSTEM SHALL BE HOT-DIPPED GALVANIZED. SCHEDULE. MECHANICAL CONNECTIONS MAY BE USED WHEN APPROVED BY WELDED HEADED STUD ASTM A108-NELSON/TRW H4L TIMBER CONNECTORS SHALL BE BY THE SIMPSON STRONG TIE COMPANY AS THE ENGINEER OR RECORD. IF TWO BARS OF UNEQUAL DIAMETER ARE SPLICED, SPECIFIED IN THEIR LATEST CATALOG. ALTERNATE CONNECTORS BY OTHER THE SPLICE LENGTH OF THE LARGER BAR SHALL CONTROL. JOINTS USING HIGH STRENGTH BOLTS WOOD FRAMING MANUFACTURES MAY BE SUBSTITUTED PROVIDED THAT THEY HAVE CURRENT · USE ASTM A325-N BOLTS. THREADS NOT EXCLUDED IN THE SHEAR PLANE. IBC CHAPTER 23 “WOOD” ICC APPROVAL FOR EQUIVALENT OR GREATER LOAD CAPACITIES AND ARE FIELD BENDING · HIGH STRENGTH BOLTED JOINTS HAVE BEEN DESIGNED AS BEARING NDS 2016 “NATIONAL DESIGN SPECIFICATION (NDS) FOR WOOD REVIEWED AND APPROVED BY THE ENGINEER OF RECORD PRIOR TO ORDERING. CONFORM TO ACI 301 SECTION 3.3.2.8. BAR SIZES #3 THROUGH #5 MAY BE FIELD CONNECTIONS. CONSTRUCTION” BENT COLD THE FIRST TIME. SUBSEQUENT BENDS AND OTHER BAR SIZES · PROVIDE ASTM BOLT GRADE AND TYPE AS SPECIFIED IN THE “MATERIALS” ANSI/AF&PA SDPWA-15 SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC CONNECTORS SHALL BE INSTALLED PER THE MANUFACTURERS INSTRUCTIONS. REQUIRE PREHEATING. DO NOT TWIST BARS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE LIST ABOVE. APA D510C-12 PLYWOOD DESIGN SPECIFICATION NAILS OR BOLTS IN EACH MEMBER. WHERE STRAPS ARE USED AS HOLD-DOWNS, · PROVIDE WASHERS OVER OUTER PLY OF SLOTTED HOLES AND OVERSIZE ANSI/TPI 1-2014 “NATIONAL DESIGN STANDARD FOR METAL PLATE NAIL STRAPS TO WOOD FRAMING JUST PRIOR TO DRYWALL APPLICATIONS, AS POST-INSTALLED ANCHORS HOLES PER RCSC TABLE 6.1 CONNECTED WOOD TRUS CONSTRUCTION” LATE AS POSSIBLE IN THE FRAMING PROCESS TO ALLOW THE WOOD TO SHRINK STANDARDS · PROVIDE NUT AND WASHER GRADES, TYPES AND FINISHES CONFORMING TO BCI “GUIDE TO GOOD PRACTICE FOR HANDLING, INSTALLING AND BRACING AND THE BUILDING TO SETTLE. PREMATURE NAILING OF THE STRAP MAY LEAD IBC CHAPTER 19 “CONCRETE” TCSC SPECIFICATION TABLE 2.1 OF METAL PLATED CONNECTED WOOD TRUSSES” TO STRAP BUCKLING AND POTENTIAL FINISH DAMAGE. · PROVIDE FASTENER ASSEMBLIES FROM A SINGLE SUPPLIER TPI DSB “RECOMMENDED DESIGN SPECIFICATION FOR TEMPORARY BRACING ACI 318-14 “BUILDING CODE REQUIREMENT FOR STRUCTURAL CONCRETE” · JOINTS SHALL BE “ST” OR SNUG TIGHT. THIS IS FOR TYPICAL BEAM END OF METAL PLATE CONNECTED WOOD TRUSSES” WHERE CONNECTORS ARE IN EXPOSED EXTERIOR APPLICATIONS IN CONTACT POST-INSTALLED ANCHORS (SHEAR TAB) CONNECTIONS, UNLESS NOTED OTHERWISE. APA REPORT TT-045B “MINIMUM NAIL PENETRATION FOR WOOD WITH THE PRESERVATIVE TREATED WOOD (PT) OTHER THAN CCA, CONNECTORS · INSTALL BOLTS IN JOINTS IN ACCORDANCE WITH THE RCSC SPECIFICATION STRUCTURAL PANEL CONNECTIONS SUBJECT TO LATER LOADS” SHALL BE EITHER BATCH HOT-DIPPED GALVANIZED (HDG), MECHANICALLY INSTALL ONLY WHERE SPECIFICALLY SHOWN IN THE DETAILS OR ALLOWED BY SECTION 8 TABLE 4.1 GALVANIZED (ASTM B695 CLASS 55 MINIMUM) STAINLESS STEEL, OR PROVIDED THE ENGINEER OF RECORD. ALL POST INSTALLED ANCHORS TYPES AND · INSPECTIONS PER RCSC SECTION 9. DEFERRED SUBMITTALS WITH 1.85 OX/SF OF ZINC GALVANIZING EQUAL TO OR BETTER THAN SIMPSON LOCATIONS SHALL BE APPROVED BY THE ENGINEER OR RECORD AND SHALL HAVE A CURRENT ICC-EVALUATION SERVICE REPORT THAT PROVIDES SUBMIT PRODUCT DATA AND PROOF OF ICC APPROVAL FOR FRAMING MEMBERS ZMAX FINISH. RELEVANT DESIGN VALUES NECESSARY TO VALIDATE THE AVAILABLE ANCHORAGE TO CONCRETE AND FASTENERS THAT HAVE BEEN DESIGNED BY OTHERS. SUBMIT STRENGTH EXCEEDS THE REQUIRED STRENGTH. ALL STEEL COLUMNS SHALL BE PROVIDED WITH A MINIMUM OF FOUR ¾” CALCULATIONS PREPARED BY THE SPECIALTY STRUCTURAL ENGINEER IN THE NAIL STRAPS TO WOOD FRAMING AS LATE AS POSSIBLE IN THE FRAMING DIAMETER ANCHOR RODS. COLUMN BASE PLATES SHALL BE AT LEAST ¾” THICK, STATE OF IDAHO FOR ALL MEMBERS AND CONNECTIONS DESIGNED BY OTHERS PROCESS TO ALLOW THE WOOD TO SHRINK AND THE BUILDING TO SETTLE. SUBMIT CURRENT MANUFACTURERS DATA AND ICC ESR REPORT TO ENGINEER UNLESS NOTED OTHERWISE. CAST-IN-PACE ANCHOR RODS SHALL BE PROVIDED ALONG WITH SHOP DRAWINGS. ALL NECESSARY BRIDGING, BLOCKING, PREMATURE NAILING OF THE STRAP MAY LEAD TO STRAP BUCKLING AND OF RECORD FOR APPROVAL REGARDLESS OF WHETHER OR NOT IT IS A UNLESS OTHERWISE APPROVED BY THE ENGINEER OR RECORD. UNLESS NOTED BLOCKING PANELS AND WEB STIFFENERS SHALL BE DETAILED AND FURNISHED POTENTIAL FINISH DAMAGE. PRE-APPROVED ANCHOR. ANCHORS SHALL BE INSTALLED IN STRICT OTHERWISE, EMBEDMENT OF CAST-IN-PLACE ANCHOR RODS SHALL BE 12 TIMES BY THE SUPPLIER. TEMPORARY AND PERMANENT BRIDGING SHALL BE THE ANCHOR DIAMETER. INSTALLED IN CONFORMANCE WITH THE MANUFACTURERS SPECIFICATIONS. FASTENERS ACCORDANCE TO ICC-ESR AND THE MANUFACTURERS PRINTED INSTALLATION DEFLECTION LIMITS SHALL BE AS NOTED UNDER DEFERRED SUBMITTALS INSTRUCTIONS IN CONJUNCTION WITH EDGE DISTANCE, SPACING, AND FASTENERS ARE TO INCLUDE NAILS, BOLTS, SCREWS, AND ALL OTHER SIMILAR 309 S DUNHAM AVE SECTION SPECIFIC DETAILS. PRODUCTS TO INCLUDE ARE: SOLID WE WOOD EMBEDMENT DEPTH AS INDICATED ON THE DRAWINGS. FABRICATION JOISTS. MEMBERS. ATTACHING TIMBER CONNECTORS (E.G. HANGARS) TO PT WOOD ARLINGTON, WA 98223 CONFORM TO AISC 360 SECTION M2. THE FOLLOWING QUALITY CONTROL (QC) SHALL HAVE SIMILAR CORROSION RESISTANCE PROPERTIES AS THE PROTECTED THE CONTRACTOR SHALL ARRANGE FOR A MANUFACTURERS FIELD STANDARDS SHALL BE CONFORMED TO: CONNECTOR. FASTENERS ATTACHING SAWN TIMBER MEMERS OR SHEATHING IDENTIFICATION REPRESENTATIVE TO PROVIDE INSTALLATION TRAINING FOR ALL PRODUCTS TO · AISSC 360 CHAPTER N “QUALITY CONTROL AND QUALITY ASSURANCE” TO PT WOOD SHALL BE CORROSION RESISTANT. VERIFY THE SUITABILITY OF BE USED, PRIOR TO THE COMMENCEMENT OF WORK. ONLY TRAINED INSTALLED ALL SAWN LUMBER AND PRE-MANUFACTURED WOOD PRODUCTS SHALL BE THE FASTENER PROTECTION/COATING WITH THE WOOD TREATMENT CHEMICAL · AISE 303 SECTION 8 “QUALITY CONTROL” SHALL PERFORM POST INSTALLED ANCHOR INSTALLATION. A RECORD OF IDENTIFIED BY THE GRADE MARK OR CERTIFICATE OF INSPECTION ISSUED BY MANUFACTURER/SUPLIER. · FABRICATOR AND ERECTOR SHALL ESTABLISH AND MAINTAIN WRITTEN QC THE CERTIFYING AGENCY. TRAINING SHALL BE KEPT ON SITE AND BE MADE AVAILABLE TO THE ENGINEER PROCEDURES PER AISC 360 SECTION N3 OF RECORD AS REQUESTED. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG · FABRICATOR SHALL PERFORM SELF-INSPECTIONS PER AISC 360 SECTION N5 SAWN LUMBER SCREWS BEARING ON WOOD. BOLTS AND LAG BOLTS ARE TO CONFORM TO TO ENSURE THAT THEIR WORK IS PERFORMED IN ACCORDANCE WITH CODE ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY INCLINED OF STANDARD PRACTICE, THE AISC SPECIFICATION, CONTRACT DOCUMENTS SAWN LUMBER SHALL CONFORM TO GRADING RULES OF WWPA, WCLIB, OR ASTM A307 AND IBC SECTION 2304.10. NAILS AND STAPLES SHALL CONFORM TO ORIENTATION SHALL BE PERFORMED BY A CERTIFIED ADHESIVE ANCHOR AND THE APPLICABLE BUILDING CODE. NLGA AND THE TABLE BELOW. FINGER JOINTED STUDS ACCEPTABLE AT ASTM F1667 AND IBC SECTION 2303.6 AND 2304.10. INSTALLER AS CERTIFIED THROUGH ACI/CRSI OR APPROVED EQUIVALENT. INTERIOR WALLS ONLY. SMITH REMODEL · QC INSPECTION MAY BE COORDINATED WITH QUALITY ASSURANCE PROOF OF CURRENT CERTIFICATION SHALL BE SUBMITTED TO THE ENGINEER INSPECTIONS PER SECTION N5.3 WHERE FABRICATORS QA PROCEDURES ENGINEERED WOOD PRODUCTS FOR APPROVAL PRIOR TO COMMENCEMENT OF INSTALLATION. PROVIDE THE NECESSARY BASIS FOR MATERIAL CONTROL, INSPECTION, AND THE FOLLOWING MATERIALS ARE BASED ON LUMBER MANUFACTURED BY CONTROL OF THE WORKMANSHIP EXPECTED BY THE SPECIAL INSPECTOR. TRUSJOIST AND WERE USED FOR THE DESIGN AS SHOWN ON THE PLANS. NO REINFORCING BARS SHALL BE DAMAGED DURING INSTALLATION OF ALTERNATE PRODUCT BY OTHER MANUFACTURERS MAY BE SUBSTITUTED POST-INSTALLED ANCHORS. ANCHOR TYPE, DIAMETER AND EMBEDMENT SHALL WELDING PROVIDED THEY HAVE CURRENT ICC APPROVAL FOR EQUIVALENT OR GREATER BE AS INDICATED ON DRAWINGS. LOAD AND STIFFNESS PROPERTIES AND ARE REVIEWED AND APPROVED BY THE THE FOLLOWING WELDING STANDARDS SHALL BE CONFORMED TO: ENGINEER OF RECORD PRIOR TO ORDERING. · WELDING SHALL CONFORM TO AWS D1.1 WITH PREQUALIFIED WELDING ADHESIVE ANCHORS PROCESSES EXCEPT AS MODIFIED BY AISC 360 SECTION J2. WELDERS SHALL THE LISTED ADHESIVE-TYPE ANCHORING SYSTEMS HAVE BEEN USED IN THE BE QUALIFIED IN ACCORDANCE WITH AWS D1.1 REQUIREMENTS. DESIGN AND SHALL BE USED FOR ANCHORAGE TO CONCRETE, AS APPLICABLE · USE 70KSI STRENGTH, LOW-HYDROGEN TYPE ELECTRODES (E7018) OR E71T AND IN ACCORDANCE WITH CORRESPONDING CURRENT ICC ESR REPORT. AS APPROPRIATE FOR THE PROCESS SELECTED. REFERENCE THE CORRESPONDING ICC ESR REPORT FOR REQUIRED MINIMUM · WELDING OF HIGH STRENGTH ANCHOR RODS IS PROHIBITED UNLESS AGE OF CONCRETE, CONCRETE TEMPERATURE RANGE, MOISTURE CONDITION, APPROVED BY ENGINEER. LIGHT WEIGHT CONCRETE, AND HOLE DRILLING AND PREPARATION REQUIREMENTS. DRILLED IN ANCHOR EMBEDMENT LENGTHS SHALL BE AS · WELDING OF HEADED STUD ANCHORS SHALL BE IN ACCORDANCE WITH AWS PERMIT 01/16/2025 D1.1 CHAPTER 7. SHOWN ON DRAWINGS. ADHESIVE ANCHORS ARE TO BE INSTALLED IN CONCRETE AGED A MINIMUM OF 21 DAYS, UNLESS OTHERWISE SPECIFIED IN THE GLULAM ICC ESR REPORT. ERECTION GLUED LAMINATED TIMER SHALL CONFORM TO AITC 117-2010 “STANDARD THE FOLLOWING ERECTION STANDARDS SHALL BE CONFORMED TO: SPECIFICATIONS FOR STRUCTURAL GLUE-LAMINATED TIMBER OF SOFTWOOD EXPANSION ANCHORS · CONFORM TO AISC 360 SECTION M4 “ERECTION” AND AISC 303 SECTION 7 SPECIES, MANUFACTURING AND DEISGN” AND ANSI/AITC A190.1 “STRUCTURAL THE LISTED EXPANSION TYPE ANCHORS ARE PRE-APPROVED FOR ANCHORAGE “ERECTION.” GLUED LAMINATED TIMER.” CAMBER ALL GLUED LAMINATED BEAMS, EXCEPT TO CONCRETE IN ACCORDANCE WITH CORRESPONDING CURRENT ICC ESR · CONFORM TO AISC CHAPTER N “QUALITY CONTROL AND QUALITY CANTILEVERED AND CONTINUOUS BEAMS, TO 3000' RADIUM, UNLESS SHOWN NAILING REQUIREMENTS REPORT. ASSURANCE” AND AISC 303 SECTION 8. THE ERECTOR SHALL MAINTAIN OTHERWISE ON THE PLANS. FABRICATE CANTILEVERED AND CONTINUOUS CONFORM TO IBC SECTION 2304.10 “CONNECTION AND FASTENERS.” UNLESS DETAILED ERECTION QUALITY CONTROL PROCEDURES THAT ENSURE THAT BEAMS FLAT, UNLESS SHOWN OTHERWISE ON PLANS. GLLULAM MEMBERS TO NOTED ON PLANS, NAIL PER TABLE 2304.10.1. NAILING FOR ROOF/FLOOR THE WORK IS PERFORMED IN ACCORDANCE WITH THESE REQUIREMENT AND CONFORM TO THE TABLE BELOW. SCREW ANCHORS DIAPHRAGMS/SHEAR WALLS SHALL BE PER DRAWINGS. NAILS SHALL BE DRIVEN THE CONTRACT DOCUMENTS. THE LISTED SCREW TYPE ANCHORS ARE PRE-APPROVED FOR ANCHORAGE TO FLUSH AND SHALL NOT FRACTURE THE SURFACE OF SHEATHING. ALTERNATE · STEEL WORK SHALL BE CARRIED UP TRUE AND PLUMB WITHIN THE LIMITS CONCRETE IN ACCORDANCE WITH CORRESPONDING CURRENT ICC ESR REPORT. NAILS MAY BE USED BY ARE SUBJECT TO REVIEW AND APPROVAL BY THE DEFINED IN AISC 303 SECTION 7.13 STRUCTURAL ENGINEER. SUBSTITUTION OF STAPLES FOR THE NAILING OF ADHESIVE · HIGH STRENGTH BOLTING SHALL COMPLY WITH THE RCSC REQUIREMENTS RATED SHEATHING IS SUBJECT TO REVIEW BY THE STRUCTURAL ENGINEER INCLUDING RCSC SECTION 7.2 “REQUIRED TESTING” AS APPLICABLE AND PRIOR TO CONSTRUCTION. HILTI HIT-HY 200 ICC ESR 3187 AISC 360 CHAPTER J, SECTION M2.5 AND SECTION N5.6 SIMPSON SET-XT ICC ESR 2508 · WELDING HEADED STUD ANCHORS SHALL BE IN ACCORDANCE WITH AWS UNLESS NOTED OTHERWISE ON PLANS, ALL NAILS ARE COMMON WIRE NAILS D1.1 CHAPTER 7 “STUD WELDING” AND ARE TO HAVE THE MINIMUM DIMENSIONS AS SHOW IN THE TABLE BELOW. EXPANSION · THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AND SAFETY HILTI KWIK BOLT TZ ICC ESR 1917 PROTECTION REQUIRED BY AISC 360 SECTION M4.2 AND AISC 303 SECTION 24081-0106 SIMPSON STRONG-BOLT 2 ICC ESR 3037 7.10 AND 7.11 S-1.1 DEWALT POWER-STUD +SD2 ICC ESR 2502 01/16/2025 GENERAL SCREW NOTES NTS SIMPSON TITEN HD ICC ESR 2713 HILTI KWIK HUZ-EZ ICC ESR 3027 DEWALT SNAKE ICC ESR 2272 LIGHT-FRAME CONSTRUCTION UNLESS NOTED ON THE PLANS, CONSTRUCTION SHALL CONFORM TO IBC SECTION 2308 “CONVENTIONAL LIGHT0FRAME CONSTRUCTION.” NAILERS ON STEEL MEMBERS WOOD 3X NAILERS ARE GENERALY REQUIRED ON ALL HSS COLUMNS AND STEEL BEAMS ABUTTING OR EMBEDDED WITHIN WOOD FRAMING. UNLESS NOTED OTHERWISE, ATTACH WITH 5/8” DIAMETER BOLTS OR WELDED STUDS AT 16” OC. UNLESS ANOTHER OTHERWISE, WOOD NAILERS ON BEAMS SUPPORTING JOIST HANGARS SHALL NOT OVERHAND THE BEAM FLANGE BY MORE THAN ¼” WOOD SHRINKAGE AND EXPANSION WOOD MATERIALS WILL EXPAND OR CONTRACT BASED ON RELATIVE CHANGES IN MOISTURE. THE CONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION RELATED TO MITIGATING AND MANAGING THE EFFECTS OF CHANGES IN MOISTURE. MOISTURE CONTENT WOOD MATERIAL USED FOR THIS PROJECT SHALL HAVE MAXIMUM MOISTURE CONTENT OF 19% EXCEPT FOR THE PRESSURE-TREATED WOOD SILL PLATE. REFER TO TESTING AND INSPECTION FOR THE VERIFICATION OF THESE LIMITS. THE MAXIMUM MOISTURE CONTENT REQUIRED MAY BE LESS THAN 19% WHEN BASED ON A PARTICULAR CLADDING/INSULATION SYSTEM. REFER TO THE ARCHITECTS DRAWINGS, AND PROJECT SPECIFICATIONS, OR WITH CLADDING INSTALLER FOR MAXIMUM RECOMMENDED MOISTURE CONTENT. SHRINKAGE COMPENSATION FOR MEP SYSTEMS MEP SYSTEMS, INCLUDING DUCTWORK, PIPES, AND OTHER ELEMENTS THAT RUN CONTINUOUSLY BETWEEN LEVELS SHALL BE INSTALLED/DESIGNED IN SUCH A MANNER TO ACCOMMODATE SHRINKAGE IN THE WOOD FRAMING. WOOD SHRINKAGE AMOUNTS WILL VARY DEPENDING ON THE CONSTRUCTION PROCESS AND MATERIALS USED. THE ANTICIPATED SHRINKAGE UNDER TYPICAL CONDITIONS IS EXPECTED TO RANGE BETWEEN 1/8” AND ¼” PER FLOOR. PRESERVATIVE TREATMENT WOOD MATERIALS THAT ARE REQUIRED TO BE “TREATED WOOD” IN ACCORDANCE WITH IBC SECTION 2304.12 “PROTECTION AGAINST DECAY AND TERMITE PROTECTION” SHALL CONFORM TO THE APPROPRIATE STANDARDS OF THE AMERICAN WOOD-PRESERVES ASSOCIATION (AWPA) FOR SAWN LUMBER BLUED LAMINATED TIMBER, ROUND POLES, WOOD PILES, AND MARINE PILES. FOLLOW AMERICAN LUMBER STANDARDS COMMITTEE (ALSC) QUALITY ASSURANCE PROCEDURES. PRODUCTS SHALL BEAR THE APPROPRIATE MARK. FASTENERS OR ANCHORS IN TREATED WOOD SHALL BE OF STAINLESS STEEL OR HOT-DIPPED GALVANIZED OR AS PER IBC 2304.10.5 MUD SILL PLATES IN NORMALLY DRY INTERIOR APPLICATIONS MAY BE TREATED WITH SODIUM BORATE (DOT-DISODIUM OCTABORATE TELRAHYDRATE) AS RECENT STUDIES HAVE NOTED LESS CONNECTOR 309 S DUNHAM AVE CORROSION POTENTIAL THAN OTHER AVAILABLE WOOD TREATMENTS OR THE ORIGINAL CCA TREATED SILL PLATES. WOOD TREATED WITH SODIUM BORATE ARLINGTON, WA 98223 SHALL BE PROTECTED DURING SHIPMENT, STORAGE, AND INSTALLATION TO MINIMIZE LEACHING OF THE WATER-SOLUBLE PRESERVATIVE FROM THE LUMBER. SODIUM BORATE PRESSURE TREATED PLATED DO NOT REQUIRE HOT-DIPPED GALVANIZED CONNECTORS. IF USING PRESERVATIVE TREATMENTS OTHER THAN CCA OR SODIUM BORATE, FASTENERS MUST BE HOT DIPPED GALVANIZED OR STAINLESS STEEL. WOOD TREATED WITH ALKALINE COPPY QUATERNARY (ACQ) REQUIRES STEEL COMPONENTS IN CONTACT WITH THE WOOD TO BE STAINLESS. FASTENERS ATTACHING TIMBER CONNECTORS TO PT WOOD SHALL HAVE SIMILAR SMITH REMODEL CORROSION RESISTANCE PROPERTIES AS THE PROTECTED CONNECTOR, THAT IS, USE HOT DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. FASTENERS ATTACHING SAWN TIMBER MEMBERS OR SHEATHING TO PRESSURE TREATED WOOD SHALL BE CORROSION RESISTANT. ALWAYS VERIFY THE SUITABILITY OF THE FASTENER PROTECTION/COATING PERMIT 01/16/2025 24081-0106 S-1.2 01/16/2025 GENERAL NOTES NTS 5" Ø X 24" SMOOTH BAR @ SLAB ON GRADE AND (3) #5 DOWELS. DRILL AND EPOXY 8" MIN 8 INTO FACE OF EXISTING FOOTING. SIMPSON 24" OC. GREASE ONE REINFORCING PER SIDE OF DOWEL PLAN, TYPICAL SET-XP EPOXY OR ACCEPTABLE TOP OF ALTERNATIVE. SLAB NEW STEM WALL, FOOTING, AND REINFORCING PER PLAN 16" MIN 4d 2 1" MIN 2 VAPOR BARRIER WHERE 6" SUBGRADE PREPARATION PER REQUIRED, TYPICAL GEOTECH REPORT, TYPICAL COMPETENT NATIVE SOIL PER 90° 45° CONSTRUCTION JOINT GEOTECH REPORT, TYPICAL R R SAW CUT OR 1 1" WIDE PREMOLDED R 180° 2 12d JOINT. DEPTH OF JOINT TO BE 1 OF THE SLAB THICKNESS 4 R FOOTING INTO PLINTH 45° TOP OF 3" SLAB R = 6d FOR #3 THROUGH #8 R = 8d FOR #9 THROUGH #11 EXISTING BASEMENT STRUCTURAL FILL. WALL 95% COMPACTION. 12" MAX LIFTS, TYP CONTROL JOINT NOTES NOTES d = DIAMETER OF REINFORCING BAR NOTES 1. CONSTRUCTION JOINT IS A JOINT BETWEEN DIFFERENT POURS. CONTROL JOINT IS A CRACK CONTROL JOINT WITHIN THE SAME POUR. R = RADIUS OF BAR BEND 1. ALL VALUES ARE IN INCHES. 2. USE EARLY ENTRY DRY-CUT SAW AS SOON AS POSSIBLE WITHOUT CAUSING RAVELING OF 2. TOP BAR IS ANY HORIZONTAL BAR WITH AT LEAST CONCRETE EDGES. SAWCUT ALONG SHORT DIRECTION OF POUR FIRST. 3. ALIGN A CONSTRUCTION OR CONTROL JOINT WITH RE-ENTRANT SLAB CORNERS EACH WAY. 12" OF MONOLITHIC POURED CONCRETE BELOW 4. PROVIDE JOINTS TO ENCLOSE APPROXIMATE SQUARE AREA (PANEL) OF 225 SQUARE FEET, MAXIMUM. MAXIMUM PANEL ASPECT RATIO OF 1.3. 5. CONTRACTOR TO SUBMIT JOINT PLAN TO STRUCTURAL ENGINEER OF RECORD FOR REVIEW/APPROVAL POST INSTALLED ANCHORS AT TYPICAL SLAB-ON-GRADE JOINT LAP SPLICE AND DEVELOPMENT 1 FOOTING INTERFACE DETAILS BAR BEND DIAGRAM LENGTH SCHEDULE SCALE: NTS 2 SCALE: 3/4" = 1' 3 SCALE: 3/4" = 1' 4 SCALE: NTS CONCRETE WALL PER PLAN DOWEL WITH STANDARD HOOK TO MATCH FOOTING REINFORCING POST PER PLAN Ld PER SCHED POST BASE PER PLAN. SLAB ON GRADE AND ACTUAL MODEL MAY NOT TOP OF REINFORCING PER PLAN BE SHOWN FOOTING CONCRETE PLINTH H ANCHORAGE PER PLAN PER PLAN 3" CLR, TYPICAL 4' MAX BEND DOWELS TO MATCH 309 S DUNHAM AVE H FOOTING REINFORCING TOP OF LAP PER SCHEDULE, 4' MAX SLAB TYPICAL (3) #4 DOWELS FROM ARLINGTON, WA 98223 FOOTING INTO PLINTH 8" MIN TOP OF FINISHED GRADE STEEP AS POSSIBLE, TYPICAL 2 BENT DOWEL TO MATCH FOOTING REINFORCING FTG 1 TURNED DOWN EDGE 1.5H MIN FOOTING REINFORCING THICKNESS PER PLAN FOOTING AND REINFORCING PER PLAN 3" CLEAR AT CORNERS AT INTERSECTIONS NOTE (2) #4 BOTTOM BAR CAST DOWELS TO MATCH VERTICAL WALL REINFORCING. NOT SHOWN PER PLAN FOR CLARITY. NOTE: SMITH REMODEL FOOTING REINFORCING PER PLAN. BOTTOM OF FOOTING BELOW FROST DEPTH PER JURISDICTION TURNED DOWN EDGE AT SLAB-ON- CORNER AND INTERSECTING POST FOOTING AT CONCRETE TYPICAL STEPPED FOOTING GRADE 7 FOOTINGS PLINTH 5 SCALE: 1/2" = 1' 6 SCALE: 1" = 1' SCALE: 3/4" = 1' 8 SCALE: 3/4" = 1' STUD WALL AND SHEATHING PER PLAN BUNDLED STUDS PER PLAN. STUD WALL AND SHEATHING PERMIT 01/16/2025 SECTION 2 STUDS, MIN. PT PLATE AND ANCHOR PIPE SLEEVE AS BOLTS PER PLAN REQUIRED, TYPICAL EXPANSION JOINT AT SLAB PT BOTTOM PLATE STEM WALL PER PLAN ON GRADE, IF APPLICABLE #4 HORIZONTAL BARS @ 18" WITH ANCHOR BOLTS PER 11/S-4.0 OC CENTERED IN WALL SLAB ON GRADE AND 1" CLR, REINFORCING WHERE OCCURS TYPICAL STRAP HOLD DOWN PER PLAN #4 HOOKED VERTICAL BARS @ 18" OC CENTERED IN WALL TOP OF CONCRETE FOOTING PER PLAN FINISHED GRADE TOP OF FOOTING 4" MIN CONCRETE STEMWALL BOT OF TOP OF PER PLAN PER PLAN FOOTING 3'-0' MAX FINISHED GRADE FOOTING DEPTH 4" MIN AT CONTRACTORS OPTION, TURNED DOWN EDGE EXCAVATION FOR TRENCH CONCRETE FOOTING AND 3'-0" MAX 6" MIN NOT ALLOWED BELOW THIS REINFORCEMENT PER PLAN EQ EQ LINE 18" MIN 1 3" CLR PLACE CONCRETE FILL 1 BEFORE FOOTING POUR ALTERNATE HOOK NOTES EVERY OTHER BAR 1. PRIOR TO CONSTRUCTION, STRUCTURAL ENGINEER OF RECORD SECTION SHALL REVIEW PIPES/SLEEVES GREATER THAN 8" DIAMETER NOTE AND/OR SPACED CLOSER THAN 3" APART. AT "SIM" CONDITION, OMIT SLAB ON GRADE, 2. ALUMINUM MATERIALS SHALL NOT BE EMBEDDED IN CONCRETE. AND EPOXY VERTICAL REINFORCING INTO EXISTING STEM WALL TO MATCH 5/S3.0 24081-0106 S-2.0 01/16/2025 TYPICAL EXTERIOR STEM WALL AND FOUNDATION DETAILS TYPICAL PIPE THROUGH FOUNDATION FOOTING AND/OR STEMWALL STRAP HOLD DOWN INSTALLATION FOOTING AS NOTED 9 SCALE: 1/2" = 1' 11 SCALE: NTS 12 SCALE: 3/4" = 1' STRAP AND NAILING PER PLAN EDGE NAILING FULL BUNDLED STUDS OR HEIGHT OF STUD EDGE NAILING PER PLAN POST PER PLAN ADDITIONAL STUD, IF HOLD DOWN PER PLAN REQUIRED PER STRAP STUD OR SHEAR WALL CONTINUES, WHERE OCCURS PER PLAN STUD OR SHEAR WALL CONTINUES, WHERE OCCURS PER PLAN STAGGER 0.131"Øx31" NAILS STAGGER 0.131"Øx31" NAILS 2 2 PER SHEAR WALL SCHEDULE PER SHEAR WALL SCHEDULE EDGE NAILING PER PLAN EDGE NAILING PER PLAN STUD WALL AND SHEATHING STUD WALL AND SHEATHING PER PLAN PER PLAN 3 CORNER AND INTERSECTING SHEAR WALLS SCALE: 1" = 1' ANCHOR BOLT PER 11/S-4.0, TYPICAL ANCHOR BOLT PER 11/S-4.0 PT SILL PLATE PER PLAN, TYIPCAL SHEATHING WHERE OCCURS PER PLAN WALL STUD SPACING HOLD DOWN PER PLAN PER PLAN, TYP TYPICAL BUNDLED STUDS PER PLAN 5" MIN, 12" MAX 5" MIN, 12" MAX NOTCH IN SILL PLATE 8" MAX WALL STUDS PER PLAN NOTES: 1. ADDITIONAL INFORMATION PER 10/S-3.0 2. TREAT NOTCHES IN SILL PLATES AS WALL ENDS. PROVIDE ANCHOR ON BOTH NOTE: SIDES. SINGLE TIMBERS MAY BE USED IN LIEU OF 3. AT SHEAR WALLS, PLATE WASHER PER SHEAR WALL SCHEDULE. STANDARD CUT BUNDLED STUDS, PROVIDED THAT TOTAL WOOD SMITH REMODEL WASHERS AT NON SHEAR WALLS. CROSS SECTION AREA REMAINS THE SAME. 7 SILL PLATE ANCHORAGE - PLAN END OF SHEAR WALLS SCALE: 1" = 1' 8 SCALE: 1" = 1' STUD WALL PER PLAN 5" MIN STUDS PER PLAN 1'-0" MAX 6'-0" MAX PERMIT 01/16/2025 5"Ø ANCHOR BOLT X 6" 8 LONG, TYPICAL WALL END PER PLAN HOLD DOWN PER PLAN PT SILL PLATE ANCHOR ROD PER PLAN TOP OF CONCRETE DRILL AND EPOXY PER PLAN EXISTING CONCRETE WALL CONCRETE STEM WALL PER PLAN NOTES: 1. PROVIDE (2) BOLTS, MINIMUM ON EACH SILL PLATE PIECE. 2. OVERSIZE HOLES ARE NOT PERMITTED. USE 11"Ø 16 DRILL BIT. 3. SILL PLATE THICKNESS PER PLAN. AT SHEAR WALLS, THICKNESS PER SHEAR WALL SCHEDULE. 4. CONTACT ENGINEER OF RECORD FOR POST INSTALLED 24081-0106 ANCHOR OPTIONS. S-3.0 01/16/2025 POST INSTALLED ANCHORS AT WOOD WALL ANCHORAGE FOOTING INTERFACE SILL PLATE ANCHORAGE - SECTION AS NOTED 11 SCALE: NTS 12 SCALE: 1/2" = 1' (2) 2x4 STUDS (3) 2x4 STUDS (3) 2x6 STUDS WALL FRAMING ABOVE, RIM JOIST PER PLAN WHERE OCCURS 1" 21" 11" 31" 11" 1 2 2 2 2 32" FRAMING AT LEVEL ABOVE, BLOCKING, WIDTH TO MATCH WHERE OCCURS HD HOLD DOWN PER PLAN, 8" TYP 8" TYP TRIMMER AND KING STUDS 6" TYP TOP OF WHERE OCCURS SHEATHING ABOVE, WHERE OCCURS RIM JOIST PER PLAN 1" 11" 11" WALL LENGTH PER PLAN 2 2 PLATE NAILING PER PLAN STRAP HOLD DOWN WHERE PONY WALL FRAMING TOP OF SHEATHING OCCURS PER PLAN BOTTOM PLATE SHEATHING PER SHEAR DOUBLE TOP PLATE WALL SCHEDULE DOUBLE TOP PLATE FIELD NAILING PER 2X BLOCKING AT PONY WALL STUDS, TO PLAN, TYP PANEL EDGES MATCH STUDS ABOVE HEADER PER PLAN 1 EDGE NAILING PER TRIMMER STUDS PER (3) 8dx34" NAILS BUNDLED STUDS PER PLAN, TYP PLAN EACH END, TYPICAL PLAN, TYPICAL SILL, IF OPENING HD HOLD DOWN AND STRAP HOLD DOWN, WHERE IS A WINDOW ANCHORAGE PER PLAN OCCURS, PER PLAN (2) 2X4 LAMINATIONS W/ (3) 2X4 LAMINATIONS W/ (1) (3) 2X6 LAMINATIONS W/ (2) (1) ROW OF 10dx31" ROW OF 10dx31" NAILS EACH ROWS OF 10dx31" NAILS EACH 2 2 2 NAILS, STAGGERED LAYER, STAGGERED BETWEEN LAYER, STAGGERED BETWEEN PONY WALL IF OPENING STUD WALL FRAMING LAYERS EACH SIDE LAYERS EACH SIDE IS A WINDOW PER PLAN PT SILL PLATE AND ANCHOR BOLTS PER PLAN CONC STEMWALL & NOTE: FOOTING PER PLAN EACH ADDITIONAL LAMINATION OVER (3) LAMINATIONS SHALL BE NAILED TO THE ASSEMBLY WITH 10dx31" COMMON WIRE NAILS, KING STUD(S) PER PLAN 4 STAGGERED EACH SIDE OF BUNDLED STUDS NAILING FOR BUNDLED STUDS TYPICAL HEADER 4 SHEAR WALL ELEVATION 2 SCALE: 3/4" = 1' 3 SCALE: 1/2" = 1' SCALE: 1/4" = 1' 2 ROWS 10dx31" NAILS, (16) 4 4'-0" MIN SPLICE LAP TOTAL, STAGGERED WITHIN AREA OF SPLICE @ 6" OC PLATE SPLICE TO OCCUR OVER STUDS DOUBLE TOP PLATE A STUD WALL PER PLAN SMITH REMODEL G B C D PLATE SPLICE DETAIL A E 6 F B SCALE: 3/4" = 1' B H MAX NOTCH DEPTH SAW CUT MAX DIAMETER OF D, MIN BETWEEN NOTCH BORED HOLE AND BORED HOLE CIRCULAR NOTCH PERMIT 01/16/2025 J "V" NOTCH MIN DEPTH MIN REMAINING DEPTH LET-IN NOTCH 1. INSTALL PANEL EITHER HORIZONTALLY OR VERTICALLY. 2. BLOCKING REQUIRED ON ALL PANEL EDGES, EXCEPT AT W6 WALLS. D, MIN BETWEEN TWO 3. SHEATHING EDGE NAILING IS REQUIRED AT ALL HOLD DOWN POSTS. EDGE NAILING MAY ALSO BE REQUIRED TO EACH STUD USED IN BUILT-UP HOLD BORED HOLES DOWN POSTS. ADDITIONAL INFORMATION PER HOLD DOWN DETAILS. D, MAX 1 1 4. BASED ON 0.131"Øx1 2" NAILS USED TO ATTACH FRAMING CLIPS DIRECTLY TO FRAMING. USE 0.131"Øx2 2" NAILS WHERE INSTALLED OVER SHEATHING. 5. FRAMING CLIPS: LTP5 MAY BE USED IN LIEU OF A35. STUD WIDTH, D STUD WIDTH, D 6. WHERE BOTTOM PLATE ATTACHMENT SPECIFIES (2) ROWS OF NAILS, PROVIDE DOUBLE JOIST, RIM JOIST, OR EQUAL BELOW. STAGGER NAILS IN ROWS 1 1" APART, MINIMUM. 2 7. ANCHOR BOLTS SHALL BE PROVIDED WITH HOT-DIPPED GALVANIZED STEEL PLATE WASHERS 0.229"x3"x3" MINIMUM. THE HOLE IN THE PLATE WASHER MAY BE DIAGONALLY SLOTTED 13"x1 3" PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND NUT. PLATE WASHER 16 4 TO EXTEND TO WITHIN 1" OF THE EDGE OF TEH SILL PLATE ON THE SIDE WITH SHEATHING. AT 2x6 WALLS WITH SHEATHING ON BOTH SIDES USE 2 PLATE WASHER 0.229"x4 1"x4 1" MINIMUM. EMBED ANCHOR BOLTS 7" MINIMUM INTO THE CONCRETE. 2 2 8. PRESSURE TREATED MATERIAL CAN CAUSE EXCESSIVE CORROSION IN THE FASTENERS. PROVIDE HOT-DIPPED GALVANIZED NAILS AND CONNECTOR PLATES (E.G. CLIPS) FOR ALL CONNECTORS IN CONTACT WITH PRESSURE TREATED FRAMING MEMBERS. ADDITIONAL INFORMATION PER STRUCTURAL GENERAL NOTES. 9. WHERE WOOD SHEATHING IS APPLIED OVER GYPSUM SHEATHING, CONTACT THE ENGINEER OF RECORD FOR ALTERNATIVE NAILING REQUIREMENTS. 10. AT ADJOINING PANEL EDGES (2) 2x STUDS NAILED TOGETHER MAY BE USED IN PLACE OF A SINGLE 3x STUD. DOUBLE 2x STUDS SHALL BE CONNECTED TOGETHER PER DETAIL 1/S-1.1. 11. CONTACT THE STRUCTURAL ENGINEER OF RECORD FOR ADHESIVE OR EXPANSION BOLT ALTERNATIVES TO CAST-IN-PLACE ANCHOR BOLTS. 24081-0106 12. NAIL STUDS TO 3X SILL PLATES WITH EITHER (2) 0.148"Øx4" END NAILS OR (4) 0.131"Øx2 1" TOENAILS. 2 13.EDGE NAILS SHALL BE LOCATED 3" FROM PANEL EDGES. 8 S-3.1 01/16/2025 STANDARD HOLES AND NOTCHES WOOD WALL FRAMING IN STUDS 11 SHEAR WALL SCHEDULE AS NOTED 10 SCALE: 3/4" = 1' SCALE: NTS 1 SHEATHING PER PLAN (2) 8d X 2 2" NAILS FROM JOIST INTO 2x BLOCKING TOP OF SHEATHING JOIST PER PLAN, TYPICAL DIAPHRAGM EDGE NAILING PER PLAN STUD WALL AND ADDITIONAL NAILING & BLOCKING 2x BLOCKING WITH SHEATHING PER PLAN BREAK RIM JOIST AT REQUIRED FOR (2) ROWS OF PLATE 1 BEAM (4) 8d X 2 2" NAILS NAILING PER SHEAR WALL SCHEDULE TOP OF 1" SHEATHING 2 PLATE ATTACHMENT PER DIAPHRAGM EDGE DTC CLIP SHEAR WALL SCHEDULE WEB STIFFENER PER JOIST NAILING PER PLAN BLOCKING @ 48" OC TO MATCH MANUFACTURER. NAIL WITH RIM JOIST PER PLAN JOISTS. MINIMUM OF (2) PER NON BEARING STUD WALL 1 PER ARCH (4) 10d COMMON NAILS X 3 2" DIAPHRAGM EDGE TOP OF WALL SEGMENT NAILING PER PLAN SHEATHING 2x4 W/ (4) 8D X 3 1" NAILS 4 PER PLAN WALL PARALLEL TOP OF BEAM PER PLAN TO JOISTS SHEATHING PER PLAN SHEATHING RIM JOIST PER PLAN TOP OF STUD WALL AND SHEATHING JOIST PER PLAN, TYPICALJOIST PER PLAN, TYPICAL JOIST PER PLAN SHEATHING PER PLAN BLOCKING @ 48" OC W/ (2) 8DX3 1" 4 RIM JOIST CONNECTION PER TOENAILS TO TOP PLATE SHEAR WALL SCHEDULE JOIST PER PLAN LSL BLOCKING TO EXISTING CONCRETE MATCH RIM JOIST WALL PER PLAN DTC CLIP RIM JOIST CONNECTION PER SHEAR WALL SCHEDULE, NON BEARING STUD WALL COLUMN F PER ARCH WALL PERPENDICULAR TO JOISTS NOTES: FLOOR FRAMING AT PARALLEL SIMPSON STRONG TIE SDPW SCREWS MAY BE USED IN LIEU OF DTC JOISTJOISTS EACH SIDE CANTILEVERED BEAM NON BEARING WALL CONNECTIONS FLOOR OVERHANG 1 SCALE: 2 SCALE: 3/4" = 1' 3 SCALE: 3/4" = 1' 4 SCALE: 3/4" = 1' ADDITION SHEAR WALL SHEATHING WHERE APPLICABLE, TYPICAL ADDITION SHEAR WALL SHEATHING WHERE APPLICABLE, TYPICAL PLATE ATTACHMENT PER PLATE ATTACHMENT PER ADDITION SHEAR WALL SHEATHING ADDITIONAL NAILING & BLOCKING SHEAR WALL SCHEDULE SHEAR WALL SCHEDULE WHERE APPLICABLE, TYPICAL REQUIRED FOR (2) ROWS OF PLATE STUD WALL AND PLATE ATTACHMENT PER NAILING PER SHEAR WALL SCHEDULE ADDITIONAL NAILING & BLOCKING ADDITION SHEAR WALL SHEATHING SHEATHING PER PLAN SHEAR WALL SCHEDULE DIAPHRAGM EDGE REQUIRED FOR (2) ROWS OF PLATE DIAPHRAGM EDGE WHERE APPLICABLE, TYPICAL NAILING PER PLAN NAILING PER SHEAR WALL SCHEDULE NAILING PER PLAN ADDITIONAL NAILING & BLOCKING DIAPHRAGM EDGE PLATE ATTACHMENT PER REQUIRED FOR (2) ROWS OF PLATE DIAPHRAGM EDGE NAILING PER PLAN SHEAR WALL SCHEDULE NAILING PER SHEAR WALL SCHEDULE NAILING PER PLAN RIM JOIST PER PLAN RIM JOIST PER PLAN ADDITIONAL NAILING & BLOCKING REQUIRED FOR (2) ROWS OF PLATE TOP OF TOP OF DIAPHRAGM EDGE SHEATHING SHEATHING NAILING PER SHEAR WALL SCHEDULE RIM JOIST PER PLAN 1 NAILING PER PLAN 2x4 W/ (4) 8D X 3 4" NAILS TOP OF RIM JOIST CONNECTION PER SHEATHING SHEAR WALL SCHEDULE WEB STIFFENER WHERE REQD TOP OF SHEATHING BY MANUFACTURER JOIST PER PLAN JOIST PER PLAN W/ (2) 8DX3 1" RIM JOIST CONNECTION PER 4 BLOCKING @ 48" OC W/ (2) 8DX3 1" NAILS TO TOP PLATE SHEAR WALL SCHEDULE 4 TOENAILS TO TOP PLATE JOIST PER PLAN W/ (2) 8DX3 1" RIM JOIST CONNECTION PER NAILS TO TOP PLATE 4 STUD WALL AND STUD WALL AND SHEAR WALL SCHEDULE SHEATHING PER PLAN 1 FULL DEPTH BLOCKING TO SHEATHING PER PLAN JOIST PER PLAN W/ (2) 8DX3 4" NAILS TO TOP PLATE MATCH RIM JOIST STUD WALL AND 2X BLOCKING WITH 2X BLOCKING WITH SHEATHING PER PLAN PLATE ATTACHMENT PER PLATE ATTACHMENT PER RIM JOIST CONNECTION PER WEB STIFFENER WHERE REQD SHEAR WALL SCHEDULE SHEAR WALL SCHEDULE SHEAR WALL SCHEDULE BY MANUFACTURER WEB STIFFENER WHERE REQD BY MANUFACTURER SMITH REMODEL 2X BLOCKING 2X BLOCKING STUD WALL AND SHEATHING PER PLAN FLOOR FRAMING AT CONTINUOUS FLOOR FRAMING PARR/PERP TO FLOOR FRAMING PERPENDICULAR JOIST WALL FLOOR FRAMING PARALLEL TO WALL TO WALL 5 SCALE: 3/4" = 1' 6 SCALE: 3/4" = 1' 7 SCALE: 3/4" = 1' 8 SCALE: 3/4" = 1' ADDITION SHEAR WALL SHEATHING STUD WALL AND ADDITION SHEAR WALL SHEATHING WHERE APPLICABLE, TYPICAL SHEATHING PER PLAN WHERE APPLICABLE, TYPICAL STUD WALL AND PLATE ATTACHMENT PER ADDITION SHEAR WALL SHEATHING STUD WALL AND PERMIT 01/16/2025 ADDITION SHEAR WALL SHEATHING SHEATHING PER PLAN SHEAR WALL SCHEDULE WHERE APPLICABLE, TYPICAL SHEATHING PER PLAN WHERE APPLICABLE, TYPICAL ADDITIONAL NAILING & BLOCKING PLATE ATTACHMENT PER PLATE ATTACHMENT PER ADDITIONAL NAILING & BLOCKING SHEAR WALL SCHEDULE PLATE ATTACHMENT PER REQUIRED FOR (2) ROWS OF PLATE DIAPHRAGM EDGE REQUIRED FOR (2) ROWS OF PLATE SHEAR WALL SCHEDULE SHEAR WALL SCHEDULE ADDITIONAL NAILING & BLOCKING NAILING PER SHEAR WALL SCHEDULE NAILING PER PLAN NAILING PER SHEAR WALL SCHEDULE ADDITIONAL NAILING & BLOCKING REQUIRED FOR (2) ROWS OF PLATE DIAPHRAGM EDGE REQUIRED FOR (2) ROWS OF PLATE NAILING PER SHEAR WALL SCHEDULE DIAPHRAGM EDGE NAILING PER SHEAR WALL SCHEDULE RIM JOIST PER PLAN NAILING PER PLAN NAILING PER PLAN DIAPHRAGM EDGE DIAPHRAGM EDGE TOP OF NAILING PER PLAN SHEATHING NAILING PER PLAN RIM JOIST PER PLAN TOP OF TOP OF TOP OF SHEATHING SHEATHING SHEATHING RIM JOIST PER PLAN 2x4 W/ (4) 8D X 3 1" NAILS 4 RIM JOIST CONNECTION PER SHEAR WALL SCHEDULE WEB STIFFENER WHERE REQD BY MANUFACTURER JOIST PER PLAN W/ (2) 8DX3 1" RIM JOIST CONNECTION PER 4 NAILS TO TOP PLATE SHEAR WALL SCHEDULE JOIST PER PLAN 1 FULL DEPTH BLOCKING TO JOIST PER PLAN W/ (2) 8DX3 1" RIM JOIST CONNECTION PER JOIST PER PLAN W/ (2) 8DX3 4" WEB STIFFENER WHERE REQD 4 NAILS TO TOP PLATE MATCH RIM JOIST BLOCKING @ 48" OC W/ (2) 8DX3 1" NAILS TO TOP PLATE SHEAR WALL SCHEDULE BY MANUFACTURER PT 2X6 PLATE, ATTACHMENT 4 PER SHEAR WALL SCHEDULE TOENAILS TO TOP PLATE WEB STIFFENER WHERE REQD RIM JOIST CONNECTION PER BY MANUFACTURER SHEAR WALL SCHEDULE CONCRETE WALL AND PT 2X6 PLATE, ATTACHMENT PT 2X6 PLATE, ATTACHMENT REINFORCING PER PLAN PER SHEAR WALL SCHEDULE PT 2X6 PLATE, ATTACHMENT PER SHEAR WALL SCHEDULE CONCRETE WALL AND PER SHEAR WALL SCHEDULE CONCRETE WALL AND REINFORCING PER PLAN REINFORCING PER PLAN CONCRETE WALL AND REINFORCING PER PLAN 24081-0106 S-3.2 01/16/2025 GROUND FLOOR FRAMING AT GROUND FLOOR FRAMING GROUND FLOOR FRAMING PARALLEL GROUND FLOOR FRAMING WOOD FLOOR FRAMING AS NOTED CONTINUOUS JOIST PARR/PERP TO WALL TO WALL PERPENDICULAR TO WALL DETAILS 9 SCALE: 3/4" = 1' 10 SCALE: 3/4" = 1' 11 SCALE: 3/4" = 1' 12 SCALE: 3/4" = 1' PT JOIST PER PLAN TOP OF SHEATHING JOIST PER PLAN W/ (2) 8DX3 1" HANGER PER PLAN 4 NAILS TO TOP PLATE LEDGER AND CONNECTION PER PLAN STUD WALL AND SHEATHING PER PLAN TOP OF SHEATHING ROOF FRAMING AT 4 SCALE: 3/4" = 1' BLOCKING AT EACH JOIST SIMPSON HU FACE MOUNT 12 HANGER AT EACH OUTRIGGER PER 5" DIAMETER WELDED 2x4 OUTRIGGER @ 24" OC ARCH 8 COUNTERSINK 1" MAX THREADED STUD @ 16" OC SHEATHING SIMPSON BA OR HB AND 6" FROM EACH END PER PLAN TOP FLANGE HANGER SHEATHING PER PLAN WITH SLOPED SEAT SHEATHING PER PLAN CONTINUOUS 3x NAILER LINE JOIST PER PLATE PLAN TOP OF SHEATHING SIMPSON H1A TIE AT EACH OUTRIGGER RAFTER PER PLAN, TYPICAL BEAM PER PLAN 2'-0" MAX BEAM PER PLAN TRUSS PER PLAN, TYPICAL SMITH REMODEL RIDGE BEAM CONNECTION WOOD NAILER OVER STEEL BEAM ROOF FRAMING PARALLEL TO WALL 6 SCALE: NTS 7 SCALE: 1" = 1' 8 SCALE: EXISTING SHEATHING USS PE 2X BLOCKING STIFFENER PL3" EACH SIDE. WOOD NAILER PER 8 CHAMFER CORNERS TO AVOID K REGION 10/S-4.2 SIMPSON VPA PERMIT 01/16/2025 EXISTING JOIST BEAM PER PLAN CONTINUOUS BEVELED PLATE 1 " 1/4 2 TYP 2'-0" MAX 1/4 2" BEAM PER PLAN HARDWARE OPTION 1 " 2 SHEATHING 1/4 3 PER PLAN WHERE BEAM IS CONTINUOUS CAP PL8" X 6" X 0'-10" 3" MIN CEILING JOISTS OVER THE SUPPORT, EXTEND WITH (2) 3" BOLTS PER PLAN ALL CALLOUTS 4 ROOF RAFTER BEAM PER PLAN, PERP LAN TYP LE TOP PLATE POST PER PLAN 2'-0" MAX BIRDS MOUTH OPTION 24081-0106 CEILING BY OTHERS S-4.2.0 01/16/2025 STEEL POST TO STEEL BEAM ROOF FRAMING PERPENDICULAR TO ROOF AND MISC FRAMING BEAM BRACE BELOW RAFTERS AS NOTED 10 CONNECTION WALL DETAILS SCALE: NTS 11 SCALE: 1" = 1' 12 SCALE: 1 2 3 4 5 6 7 8 2 3/4" 2 3/4" I SONOTUBE O/24" BIG FOOT BF24 FOOTING VERIFY WITH STRUC. CONFIRMED. CAST 5/8" Ø ANCHOR ROD 6" INTO SONOTUBE TO RECEIVE SIMPSON ABU66Z POST BASE. 28'-0 1/2" TYPICAL AT (5) LOCATIONS 14'-0 1/4" 14'-0 1/4" 30" WIDE x 14" DP CONCRETE FOOTING WITH (3) #5 BOTTOM BARS EACH WAY BELOW POST SIMPSON STHD14 ABOVE. HOLD DOWN 11 H S-2.0 NEW CONCRETE STEMWALL 6" THICK 3'-0" WITH #4 BAR TOP AND BOTTOM AND VERTICALS #4 BARS @ 24" OC G DOWEL AND EPOXY NEW WALL NEW CONCRETE FOOTING 12" 30" SQ x 14" DP CONCRETE FOOTING 11'-4 1/2" WIDE x 6" DP WITH (2) #4 BARS 6" STEM WALL ~2' TALL WITH (3) #5 BOTTOM BARS EACH WAY. TYPICAL AT (3) 16" X 8" D FOOTING BELOW NOT DRIVING DIMENSION 15'-0" BOTTOM OF FOOTING 2'-0" BELOWREBAR PER STRUC. LOCATIONS 12 TOP OF GRADE TO DECREASE EFFECT PROPOSED ADDITION8 DRIVING DIMENSION S-2.0 12'-0"ON ADJACENT BASEMENT WALL S-2.0 VENTED CRAWLSPACE TYPICAL DOWEL AND EPOXY NEW WALL F 1 S-2.0 EXISTING FULL HEIGHT BASEMENT FOUNDATION WALL OLD ADDITION STEM WALLS 1 3'-0" S-2.0 E Copyright 2020 Sno Valley Cottages, LLC All rights reserved. DRILL AND EPOXY 1/2" Ø CAST 5/8" Ø ANCHOR ROD 6" 11 ANCHOR ROD 6" INTO TOP INTO SONOTUBE TO RECEIVE No. Date S-3.0 OF EXISTING CONCRETE SIMPSON ABU66Z POST BASE. WALL. NOT FOR CONSTRUCTION WH 24" SQ x 12" DP CONCRETE CAST 5/8" Ø ANCHOR ROD 6" FOOTING WITH (2) #5 INTO SONOTUBE TO RECEIVE BOTTOM BARS EACH WAY. SIMPSON ABU66Z POST BASE. Issue Date D FOUNDATION PLAN NOTES: 1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0, S-1.1, AND S-1.2. C EXISTING BASEMENT Drawn by:Author 2.CONTRACTOR SHALL LOCATE AND VERIFY THE FOLLOWING WITH OTHERS PRIOR TO POURING CONCRETE: ALL DOOR OPENINGS AND BLOCKOUTS IN FOUNDATION WALLS; DRAINS AND SLOPES; ALL DUCTS, CHASES AND PIPES PER MECHANICAL, PLUMBING AND ELECTRICAL. FOUNDATION & FRAMING PLAN 3.TOP OF SLAB ON GRADE ELEVATION ASSUMED 0’-0”. PROVIDE 6 MIL POLYETHELENE VAPOR BARRIER BELOW SLAB ON GRADE AT INTERIOR SPACES. Scale: B 1/4" = 1'-0" 4.TOP OF WALL TO BE A MILNIMUM OF 8” ABOVE FINISHED GRADE. DAMPROOF WALLS BY OTHERS. 5.ALL FOOTINGS AND SLABS TO BEAR ON COMPETENT NATIVE SOIL AND/OR STRUCTURAL FILL. SUBGRADE PREPARATION, STRUCTURAL FILL, FOOTING DRAINS, AND OTHER A REQUIREMENTS PER GEOTECH REPORT AS NOTED IN THE STRUCTURAL GENERAL NOTES. 6.ALL REINFORCING TO BE GRADE 60. PROVIDE 3” CLEAR COVER FROM BOTTOM OF MATCH PORCH 9 FOOTING. POST FOOTINGS 7.ALL WOOD EXPOSED TO CONRETE, WEATHER, OR WITHIN 8” OF FINISHED GRADE SHALL BE PRESSURE-TREATED. 8.PROVIDE HOT-DIPPED GALVANAIZED ANCHOR BOLTS AT PRESSURE TREATED SILL PLATES. 9.ADDITIONAL TYPICAL DETAILS NOT CUT ON PLAN PER S-2.0 SHEETS. NOT ALL DETAILS MAY BE APPLICABLE. 1 FOUNDATION PLAN 1/4" = 1'-0" ARLINGTON, WA 309 S DUNHAM AVE VIRTUS STAMP AND SCOPE 309 S DUNHAM AVE ADDITION ENCOMPASSES THE PRIMARY STRUCTURAL ELEMENTS AS SHOWN IN THE REDLINE MARKUPS, ONLY. PROJECT: SMITH REMODEL PROJECT NUMBER: 24081-0106 DATE: 01/21/2025 Job No.: 23-15 DESCRIPTION: FOUNDATION PLAN DRAWN BY: CDA A3.1 _______ - 28'-0 1/2" 14'-0 1/4" 14'-0 1/4" 9 1 - 2 3 4 5 6 7 8 9 _______ --- 1 2 3 4 5 6 7 8 H DIM. TO CL OF POST - _______ I --- G (N)GLULAM BEAM ABV. 39'-1 7/8" COVERED PORCH ADDITION VAULTED CEILING 4/12 SLOPE (N) VENTED CRAWLSPACE (N) FOUNDATION, SEE FDN PLAN GUARDRAILS REQUIRED IF DECK SURFACE MORE THAN 30" ABOVE GRADE - _______ --- WINDER REQUIRED 12'-9 1/4" TO MEET HEADROOM (E) FOUNDATION, SEE FDN PLAN PER CODE-6'-8" MIN. 13'-9 1/4" 14'-3 1/4" NEW ADDITION 9'-4 3/4" 4'-4 1/2" 2'-7 1/4" 4'-7" 4'-7" 2'-6" 4'-1" F DIM. TO F2 F1 FACE OF DIM. TO CONC. 10'-0 3/8" 2'-5 1/2" 6'-8 1/2" 9'-3 3/8" 9'-8 1/8" FACE OF 9'-4 3/4" 4'-4 1/2" D2 CONC. E (E) VENTED CRAWLSPACE H W4 F5 F4 F3 - _______ 3'-0" --- W4 - 4'-0" 2 NEW ADDITION _______ --- = W5 D13 (N) BATH G 4'-3" (N) BEDROOM 3 3'-2 3/4"D21 3'-6" STUD AND SHEAR WALL PLAN NOTES: 5'-10 1/4" DW DN CL. (N) STORAGE 5'-9 1/2"1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0, (N) DINING S-1.1, AND S-1.2. EGRESS REMOVE WINDOW D3 9'-0 1/2" = AND FILL IN WITH 11'-4 1/2" F23 2.LUMBER GRADE PER STRUCTURAL GENERAL NOTES.FRAMING ALIGN NEW FRAMING CONVERT TO EGRESS WINDOW STAIRS: W4 TO CORNER (E) WALL SILL AT +44" A.F.F. MAX. 14RISERS 3'-9 3/4" (N) KITCHEN AT 7" 3.ALL INTERIOR NON-BEARING, NON-STRUCTURAL WALL STUD REQUIREMENTS PER2X4 INTERIOR WALL, TYP. VAULTED CEILING 4/12 SLOPE REMOVE SIDING 13'-3 7/8" WH 1/2" AIR GAP FROM CONCRETE ON EXT. WALL 5'-6 1/4" S LINEN S STRUCTURAL GENERAL NOTES. 12'-0" 2'-0" W3 F22 13'-0 1/8" STAIR OPENING Range D18 D17 D16 5'-10" 3'-6 5/8" 4.UNLESS NOTED OTHERWISE ON PLAN: HEADERS TO BE (2) 2x8, TO BE SUPPORTED BY (1) 7'-8 3/8"TRIMMER AND (1) KING STUD MINIMUM, CONNECTION HEADERS INTO KING STUD WITH (4) FULL HEIGHT WALL F 3'-10" D19 6x6 POST D15 STUB FOR TOTAL 10d END NAILS EACH SIDE. KING STUDS TO BE CONNECTED TOP AND BOTTOM WITH 6'-4 7/8" S/CM 7'-9 1/8" STAIR OPENING FUTURE SINK 1 (E) WIN. COULD REMAIN 24'-0" 3'-11 5/8" GRINDER (4) 10d TOE NAILS, UNLESS NOTED OTHERWISE ON PLAN. (N) MECH. 2'-9 7/8" PUMP STORAGE CL VANITY ABV. ISLAND 10' X 5' S PANTRY (E) MASTER BEDROOM CLOSET 5.ALL TRIMMERS TO BE CONTINUOUS TO FOUNDATION. 7'-10 1/8" D DBL OvenOVEN E 28'-0" ALIGN 8'-1 1/4" D14 CL TOILET ABV. 6x6 POST 6x6 POST 3'-6 5/8" 6.ALL BEAMS, EXCLUDING HEADERS, SHOWN ON FRAMING PLAN SHALL BE SUPPORTED BY (2) ALIGN WALL ON CENTER W/POST - FLUSH INSIDE FACE OF WALL BUNDLED STUDS OR 4X MEMBER, MINIMUM UNLESS NOTED OTHERWISE ON PLAN. ALL_______ 9'-0 5/8" 28'-0" EXISTING BASEMENT OF POST 7'-2" --- (N) SKYLIGHT OVER THE STAIRS TO INSIDE FACE OF BEAM BUNDLED STUDS TO BE CONTINUOUS TO FOUNDATION.(N)GLULAM 2'-0" C BEAM ABV. (E) DOOR OPENING Refrigerator CL SHOWER DRAIN ABV. ALTER AS NEEDED PER DOOR CL VANITY ABV. 7.ALL EXTERIOR WALLS TO BE CONTINUOUSLY SHEATHED PER SHEAR WALL SCHEDULE 8'-10 1/8" W3 LOCATE WITHIN 3' OF PEAK D9 SELECTION F21 F24 W5 D20 11-S3.1 “UNBLOCKED W6”, UNLESS NOTED OTHERWISE ON PLAN. CL WASHER ABV. EGRESS Copyright 2020 Sno Valley Cottages, LLC All rights reserved. (N)6X6 POST-BEARING TO CABINETS/COUNTER 3'-3 1/2" 2'-10 1/4" 4'-0 1/8" 2'-4" 2'-6" (N) OFFICE (N) BONUS ROOM 8.ALL SHEAR WALLS INDICATED ON PLAN TO HAVE (2) BUNDLED STUDS AT WALL ENDS, 4'-0" F6 (N) WALL BELOW TO FTG. 6'-1 3/8" UNLESS NOTED OTHERWISE ON PLAN. HOLD DOWNS ARE AS INDICATED ON PLAN, AND MAY W1 No. Date 9'-4 3/4" F25 2'-1 1/2" CL TOILET ABV. 3'-4 1/2" NOT BE REQUIRED AT SOME WALLS. S (N) BATHROOM 13'-6" TO CL OF (E) BEAM AND POSTS 9.POST BASES AND CAPS, WHERE NECESSARY, ARE INDICATED ON PLAN. D8 CL. = B MATCH CL PLUMBING WALL ABV. DIM. TO = D10 CL SHOWER DRAIN ABV. 2'-11" 10.FABRICATE ALL STEEL COLUMNS -¼” PER FLOOR TO ALLOW FOR WOOD SHRINKAGE. WALL AT +42" A.F.F. D7 FACE OF 15'-8 1/2" W6 66" VANITY 5'-11 1/4" 4'-0" CONC. DN 4'-9" = 5'-4" 15'-11 1/4" TO STAIR OPENING CLOSET 11.WALL ANCHORAGE AND OTHER TYPICAL WALL FRAMING DETAILS PER SHEETS S-3.0 AND3'-10 7/8" = CONFIRM RO WITH POCKET DOOR SPECS 1'-4" MIRROR DIM. ON FIREPLACE CENTER 7'-9 1/8" (2)2X NOT FOR S-3.1. NOT ALL DETAILS MAY BE APPLICABLE.CONSTRUCTIONFIREPLACE D11 3 1/2" D 3'-3 1/2" SHOWER/TOILET A MATCH (N) GREAT ROOM = FLAT CEILING AT 7' 10-3/4" EXISTING RESIDENCE F20 4'-0" 2'-0" MIRROR DIM. ON FIREPLACE CENTER REBUILD FP AT INTERIOR (N)6x6 POST-BEARING TO METAL RAILING 3'-1" 3'-8 1/4"S/CM SHOWER 4'-3 1/2" F7 AT +36" A.F.F. 4' W X 3' D = Issue Date TO CENTER BEAM BELOW C - ON BEAMS ABV. AND STAIR D4 D5 _______ --- S ADD 2' X 2' SKYLIGHT ABOVE F8 7'-6" 9'-0 1/2" 30'-1 3/8" W1 (N) GLULAM BEAM ABV. 42" VANITY 4'-9 7/8" (N) BEDROOM 2 F19 Author F9 4'-2 1/2"4'-2 1/2" 3'-4 1/2"(N) BATH W2 1'-0" Drawn by: D12 5'-0" BENCH/CUBBIES/CABS 9'-7 5/8" B 2 BASEMENT LEVEL 7'-6" W3 F18 1/4" = 1'-0" 6'-2 7/8" 1'-4 3/8"1'-4 3/8" CLOSET F10 F11 F12 1'-3 1/2" 4'-5 1/2"2'-10" 2'-2" 2'-4 1/2" 6'-7 7/8" 6'-7 7/8" 4'-9 7/8" REMODEL/ADDITION FLOOR PLANS 3'-1 3/8" EGRESS Scale: FLOOR PLAN NOTES D1 As indicated SMOKE ALARMS AND HEAT DETECTION A FRAMING: 2X6 EXTERIOR WALLS REQUIRED LOCATIONS R314.3: FRAMING - DOOR SCH. 1'-6" 3'-0" 7'-6" SMOKE ALARMS/CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN: 2X4/6's AT INTERIOR WALLS UNLESS NOTED OTHERWISE 1. IN EACH SLEEPING ROOM OR SLEEPING LOFT NO. DOOR SIZE HEAD HEIGHT COMMENTS F13 F14 F15 F16 F17 FILL IN 2X4 FRAMING 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE BASEMENT FF AT ALL MODIFIED SEE STRUCTURAL NOTES FOR STUD SCHEDULE. VICINITY OF THE BEDROOMS. D13 2'-6" 6'-8" 6'-8" COVERED WINDOW OPENINGS 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING CONCEALED SPACES SHALL BE FIRESTOPPED IN BOTH DIRECTIONS AT BASEMENTS AND HABITABLE ATTICS. D14 2'-10" 6'-8" 6'-8" NEW ADDITION - PORCH 10" ON CENTER AND AT FLOORS. TYPICAL. 4. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET FROM D15 2'-6" 6'-8" 6'-8" _______ --- THE DOOR OR OPENING OF A BATHROOM. D16 2'-4" 6'-8" 6'-8" ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH D17 1'-8" 6'-8" 6'-8" DN HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. THE LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER D18 2'-6" 6'-8" 6'-8" MINIMUM CLEAR OPENING HEIGHT DIMENSION SHALL BE 24". MINIMUM THAN 24". CLEAR OPENING WIDTH DIMENSION SHALL BE 20". SILL HEIGHT SHALL D19 2'-6" 6'-8" 6'-8" NOT BE MORE THAN 44" ABOVE THE FLOOR. ALTERATIONS, REPAIRS AND ADDITIONS R314.2.2 WHERE ALTERATIONS, D20 2'-6" 6'-8" 6'-8" REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHERE ONE OR D21 5'-0" 6'-8" 6'-8" SHOWER COMPARTMENTS AND WALLS AROUND BATHTUBS WITH MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DEMO 2'-6" 6'-8" 6'-8" SHOWERS SHALL BE FINISHED WITH A SMOOTH NON-ABSORBANT DWELLINGS, OR WHERE AN ACCESSORY DWELLING UNIT IS CREATED DEMO 2'-6" 6'-8" 6'-8" SURFACE TO NOT LESS THAN 72" ABOVE THE FLOOR (IRC R307.2). WITHIN AN EXISTING DWELLING UNIT, EACH DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS AS REQUIRED FOR NEW DWELLINGS. MAIN LEVEL ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN D1 3'-0" 6'-8" 6'-8" D2 1 MAIN LEVEL OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM OF 3/4" D2 6'-0" 6'-8" 6'-8" 1/4" = 1'-0" ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D3 6'-0" 6'-8" 6'-8" DOOR AND TRANSFER GRILLE ABOVE DOOR. HEAT DETECTION INTERCONNECTION R314.4.1 HEAT DETECTORS AND HEAT ALARMS SHALL BE CONNECTED TO AN ALARM OR A SMOKE ALARM D4 2'-6" 6'-8" 6'-8" PROVIDE WEATHER RESISTANT FIBER CEMENT WALLBOARD UNDER TUB THAT IS INSTALLED IN THE DWELLING. ALARMS THAT ARE INSTALLED FOR D5 2'-8" 6'-8" 6'-8" AND SHOWER ENCLOSURE MATERIALS TO A HEIGHT OF 70" MINIMUM THIS PURPOSE SHALL BE LOCATED IN A HALLWAY, ROOM, OR OTHER D6 2'-6" 6'-8" 6'-8" ABOVE THE DRAIN INLET. LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION. D7 2'-6" 6'-8" 6'-8" FLOOR PLAN KEY NOTES ARLINGTON, WA D8 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN COMBINATION ALARMS R314.5 COMBINATION SMOKE AND CARBON OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM ? 3/4" MONOXIDE ALARMS MAY BE USED IN PLACE OF SMOKE ALARMS. D9 6'-0" 6'-8" 6'-8" NO. DESCRIPTION ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D10 5'-0" 6'-8" 6'-8" 1 EXISTING SEWER ~5' ABOVE FFE DOOR AND TRANSFER GRILLE ABOVE DOOR. POWER SOURCE R314.6 SMOKE ALARMS, HEAT ALARMS, AND HEAT D11 2'-6" 6'-8" 6'-8" 2 EXISTING ELECTRICAL PANEL-150 AMP, UPGRADE TO 200 AMP DETECTORS SHALL RECEIVE PRIMARY POWER FROM THE BUILDING D12 5'-0" 6'-8" 6'-8" 1. A CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH WIRING AND, WHEN POWER IS INTERRUPTED, SHALL RECEIVE POWER SEPARATE SLEEPING AREA IN IMMEDIATE VICINITY OF BEDROOMS D22 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ADDITION FROM A BATTERY. VIRTUS STAMP AND SCOPE AND ON EACH LEVEL PER 2015 IRC R315. DEMO 2'-0" 6'-8" 6'-8" ENCOMPASSES THE PRIMARY 2. A SMOKE DETECTOR SHALL BE INSTALLED IN EACH HABITABLE ROOM. INTERCONNECTIVITY R314.4 WHERE MORE THAN ONE SMOKE ALARM IS DEMO 2'-4" 6'-8" 6'-8" 3. A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH REQUIRED TO BE INSTALLED, THE ALARM DEVICES SHALL BE DEMO 5'-0" 6'-8" 6'-8" STRUCTURAL ELEMENTS AS SHOWN FLOOR. INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE IN THE REDLINE MARKUPS, ONLY. DEMO 2'-6" 6'-8" 6'-8" 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING DEMO 2'-6" 6'-8" 6'-8" LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL NOT BE PROJECT: SMITH REMODEL PROJECT NUMBER: 24081-0106 THAN 24". REQUIRED WHERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL DEMO 2'-0" 6'-8" 6'-8" 5. SMOKE DETECTORS SHALL BE 110V HARDWIRED, INTERCONNECTED, ALARMS SOUND UPON ACTIVATION OF ONE ALARM. Job No.: 23-15 WITH BATTERY BACKUP, PER 2015 IRC R314. WHERE AN ACCESSORY DWELLING UNIT IS CREATED WITHIN AN EXISTING DATE: 01/21/2025 NOTE: A SPRINKLER SYSTEM IS NOT REQUIRED FOR THIS RESIDENCE. DWELLING UNIT ALL REQUIRED SMOKE ALARMS, IN THE ACCESSORY DWELLING UNIT AND THE PRIMARY DWELLING UNIT, SHALL BE DESCRIPTION: BASEMENT POST PLAN DRAWN BY: CDA INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL ALARMS IN BOTH THE PRIMARY DWELLING UNIT A2.0 AND THE ACCESSORY DWELLING UNIT _______ - 28'-0 1/2" 11 14'-0 1/4" 14'-0 1/4" 9 2 3 5 S-3.2 6 7 9 1 - 4 8 _______ --- 1 2 3 4 5 6 7 8 H DIM. TO CL OF POST - _______ I --- G 6x6 POST 6x6 POST 6x6 POST (N)GLULAM BEAM ABV. 39'-1 7/8" COVERED PORCH ADDITION 12 VAULTED CEILING 4/12 SLOPE (N) FOUNDATION, SEE FDN PLAN GUARDRAILS REQUIRED IF DECK SURFACE (N) VENTED CRAWLSPACE S-3.2 TYPICAL AT NEW MORE THAN 30" ABOVE GRADE - CONSTRUCTION, UNLESS _______ 11 7/8" DP TJI 210 @ 24" OC 11 7/8" DP TJI 210 @ 24" OC NOTED OTHERWISE --- WINDER REQUIRED 12'-9 1/4" TO MEET HEADROOM (E) FOUNDATION, SEE FDN PLAN PER CODE-6'-8" MIN. 13'-9 1/4" 14'-3 1/4" NEW ADDITION 9'-4 3/4" 4'-4 1/2" 2'-7 1/4" 4'-7" 4'-7" 2'-6" 4'-1" GL 5 1/2" x 10 1/2" F DIM. TO F2 F1 NEW WALLS TO BE 2x6 @ 16" FACE OF DIM. TO CONC. 10'-0 3/8" 2'-5 1/2" 6'-8 1/2" 9'-3 3/8" 9'-8 1/8" FACE OF 9'-4 3/4" 4'-4 1/2" D2 OC WITH (3) 8d TOE NAILS TOP 3'-0" CONC. E 6x6 POST AND BOTTOM H (E) VENTED CRAWLSPACE W4 4x8 HDR F5 F4 F3 - _______ 3'-0" W6 BLOCKED --- W4 - 4'-0" 2 NEW ADDITION SHEAR WALL 6x6 POST _______ --- = W5 D13 (N) BATH G 4'-3" (N) BEDROOM 3 1 3'-2 3/4"D21 3'-6" 4x8 HDR 5'-10 1/4" S-3.2 CL. (N) STORAGE DW DN 5'-9 1/2" 6x6 POST (N) DINING EGRESS REMOVE WINDOW D3 9'-0 1/2" = AND FILL IN WITH 11'-4 1/2" F23 FRAMING ALIGN NEW FRAMING 4x8 HDR CONVERT TO EGRESS WINDOW STAIRS: 2x8 @ 24" OC, MIN W4 TO CORNER (E) WALL SILL AT +44" A.F.F. MAX. 14RISERS 3'-9 3/4" (N) KITCHEN AT 7" 2X4 INTERIOR WALL, TYP. VAULTED CEILING 4/12 SLOPE REMOVE SIDING 13'-3 7/8" WH 1/2" AIR GAP FROM CONCRETE ON EXT. WALL 5'-6 1/4" S LINEN S 12'-0" 2'-0" W3 F22 13'-0 1/8" STAIR OPENING Range D18 D17 D16 5'-10" 3'-6 5/8" 4x8 7'-8 3/8" FULL HEIGHT WALL F 3'-10" D19 D15 STUB FOR 6'-4 7/8" 4x8 HDR S/CM 7'-9 1/8" STAIR OPENING FUTURE SINK 1 (E) WIN. COULD REMAIN 24'-0" 3'-11 5/8" GRINDER (N) MECH. 2'-9 7/8" PUMP W6 BLOCKED STORAGE CL VANITY ABV. ISLAND 10' X 5' S PANTRY (E) MASTER BEDROOM CLOSET SHEAR WALL 7'-10 1/8" D DBL OvenOVEN E 28'-0" ALIGN 8'-1 1/4" D14 CL TOILET ABV. 3'-6 5/8" ALIGN WALL ON CENTER W/POST - (4) 2x4 OR FLUSH INSIDE FACE OF WALL _______ 4x6 POST 9'-0 5/8" 28'-0" EXISTING BASEMENT OF POST 7'-2" --- 4x6 POST (N) SKYLIGHT OVER THE STAIRS TO INSIDE FACE OF BEAM (N)GLULAM C BEAM ABV. 2'-0" SIMPSON DTT2Z HOLD(E) DOOR OPENING Refrigerator CL VANITY ABV. CL SHOWER DRAIN ABV. DOWN ALTER AS NEEDED PER DOOR 8'-10 1/8" W3 LOCATE WITHIN 3' OF PEAK D9 SELECTION F21 F24 W5 D20 CL WASHER ABV. EGRESS Copyright 2020 Sno Valley Cottages, LLC All rights reserved. (N)6X6 POST-BEARING TO CABINETS/COUNTER 3'-3 1/2" 2'-10 1/4" 4'-0 1/8" 2'-4" 2'-6" (N) OFFICE (N) BONUS ROOM 4'-0" F6 (N) WALL BELOW TO FTG. 6'-1 3/8" W1 4x8 HDR No. Date 9'-4 3/4" F25 2'-1 1/2" CL TOILET ABV. 3'-4 1/2" 4x8 HDR S (N) BATHROOM 13'-6" TO CL OF (E) BEAM AND POSTS D8 CL. = B MATCH CL PLUMBING WALL ABV. DIM. TO = D10 CL SHOWER DRAIN ABV. 2'-11" WALL AT +42" A.F.F.6x6 POST D7 FACE OF 15'-8 1/2" W6 66" VANITY 5'-11 1/4" 4'-0" CONC. DN 4'-9" = 5'-4" 15'-11 1/4" TO STAIR OPENING CLOSET 3'-10 7/8" 1'-4" MIRROR DIM. ON FIREPLACE CENTER 7'-9 1/8" = CONFIRM RO WITH POCKET DOOR SPECS (2)2X NOT FOR CONSTRUCTIONFIREPLACE D11 3 1/2" D 3'-3 1/2" SHOWER/TOILET A MATCH (N) GREAT ROOM = EXISTING RESIDENCE FLAT CEILING AT 7' 10-3/4"6x6 POST 6x6 POST 4'-0" 2'-0"F20 MIRROR DIM. ON FIREPLACE CENTER REBUILD FP AT INTERIOR (N)6x6 POST-BEARING TO METAL RAILING 3'-1" 3'-8 1/4"S/CM SHOWER 4'-3 1/2" F7 AT +36" A.F.F. 4' W X 3' D = 4x8 HDR Issue Date TO CENTER BEAM BELOW C - ON BEAMS ABV. AND STAIR D4 D5 _______ --- S ADD 2' X 2' SKYLIGHT ABOVE F8 7'-6" 9'-0 1/2" 30'-1 3/8" W1 4x12 HDR (N) GLULAM BEAM ABV. 42" VANITY 4'-9 7/8" (N) BEDROOM 2 F19 Author F9 4'-2 1/2"4'-2 1/2" 3'-4 1/2"(N) BATH W2 1'-0" Drawn by: 4x12 HDR D12 5'-0" BENCH/CUBBIES/CABS 9'-7 5/8" 4x10 HDR B 2 BASEMENT LEVEL 7'-6" W3 F18 1/4" = 1'-0" 6'-2 7/8" 1'-4 3/8"1'-4 3/8" 4x6 POST CLOSET F10 F11 F12 1'-3 1/2" 4'-5 1/2"2'-10" 2'-2" 2'-4 1/2" 6'-7 7/8" 6'-7 7/8" 4'-9 7/8" FLOOR FRAMING PLAN NOTES: STUD AND SHEAR WALL PLAN NOTES: 3'-1 3/8" REMODEL/ADDITION FLOOR PLANS FLOOR PLAN NOTES1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0, 1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0, 4x8 HDRD1 4x12 HDR EGRESS Scale: As indicated SMOKE ALARMS AND HEAT DETECTION S-1.1, AND S-1.2. A S-1.1, AND S-1.2. FRAMING: 2X6 EXTERIOR WALLS REQUIRED LOCATIONS R314.3: FRAMING - DOOR SCH. 4x8 HDR1'-6" 4x8 HDR3'-0" 7'-6" SMOKE ALARMS/CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN: 2X4/6's AT INTERIOR WALLS 2.LUMBER GRADE PER STRUCTURAL GENERAL NOTES. UNLESS NOTED OTHERWISE2.ALL DUCTS CHASES AND PIPES SHALL BE PER MECHANICAL, PLUMBING, ELECTRICAL AND1. IN EACH SLEEPING ROOM OR SLEEPING LOFT NO. DOOR SIZE HEAD HEIGHT COMMENTS (2) 2x4 F13 (2) 2x4 F14 F15 F16 F17 FILL IN 2X4 FRAMING 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE SPRINKLER DRAWINGS. BASEMENT FF AT ALL MODIFIED SEE STRUCTURAL NOTES FOR STUD SCHEDULE. VICINITY OF THE BEDROOMS. D13 2'-6" 6'-8" 3.ALL INTERIOR NON-BEARING, NON-STRUCTURAL WALL STUD REQUIREMENTS PER6'-8" COVERED WINDOW OPENINGS 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING CONCEALED SPACES SHALL BE FIRESTOPPED IN BOTH DIRECTIONS AT 3.23/32 FLOOR SHEATHING PER STUCTURAL GENERAL NOTES. SHEATHING TO BE GLUEDBASEMENTS AND HABITABLE ATTICS. D14 2'-10" 6'-8" STRUCTURAL GENERAL NOTES.6'-8" NEW ADDITION - PORCH 10" ON CENTER AND AT FLOORS. TYPICAL.AND NAILED TO FLOOR FRAMING WITH 8d X 2 ½4. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET FROM” COMMON WIRE NAILS @ 6” OC AT D15 2'-6" 6'-8" 6'-8" _______ --- SUPPORTED PANEL EDGES, AND 12” OC FIELD NAILING. LAY SHEATHING THE LONGTHE DOOR OR OPENING OF A BATHROOM. D16 2'-4" 6'-8" 4.UNLESS NOTED OTHERWISE ON PLAN: HEADERS TO BE (2) 2x8, TO BE SUPPORTED BY (1)6'-8" ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH DIRECTION PERPENDICULAR TO SUPPORTS AND STAGGER PANEL END JOINTS. ALLOW 1/8LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER” D17 1'-8" 6'-8" TRIMMER AND (1) KING STUD MINIMUM, CONNECTION HEADERS INTO KING STUD WITH (4)6'-8" DN HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. THE D18 2'-6" 6'-8" TOTAL 10d END NAILS EACH SIDE. KING STUDS TO BE CONNECTED TOP AND BOTTOM WITH6'-8" MINIMUM CLEAR OPENING HEIGHT DIMENSION SHALL BE 24". MINIMUM SPACE BETWEEN PANEL ENDS AND EDGES. THAN 24". 6x6 POST 6x6 POST CLEAR OPENING WIDTH DIMENSION SHALL BE 20". SILL HEIGHT SHALL D19 2'-6" 6'-8" (4) 10d TOE NAILS, UNLESS NOTED OTHERWISE ON PLAN.6'-8" NOT BE MORE THAN 44" ABOVE THE FLOOR.4.ALL WOOD EXPOSED TO CONCRETE, WEATHER, OR WITHIN 8ALTERATIONS, REPAIRS AND ADDITIONS R314.2.2 ” OF FINISHED GRADE SHALLWHERE ALTERATIONS, D20 2'-6" 6'-8" 6'-8" REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHERE ONE OR D21 5'-0" 6'-8" 5.ALL TRIMMERS TO BE CONTINUOUS TO FOUNDATION.6'-8" SHOWER COMPARTMENTS BE PRESSURE TREATED.AND WALLS AROUND BATHTUBS WITH MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DEMO 2'-6" 6'-8" 6'-8" SHOWERS SHALL BE FINISHED WITH A SMOOTH NON-ABSORBANT DWELLINGS, OR WHERE AN ACCESSORY DWELLING UNIT IS CREATED SURFACE TO NOT LESS THAN 72" ABOVE THE FLOOR (IRC R307.2). WITHIN AN EXISTING DWELLING UNIT, EACH DWELLING UNIT SHALL BE DEMO 2'-6" 6'-8" 6.ALL BEAMS, EXCLUDING HEADERS, SHOWN ON FRAMING PLAN SHALL BE SUPPORTED BY (2)6'-8" 5.ALL 2X HANGERS TO BE TOP FLANGE BEARING SIMPSON JB TYPE, UNLESS NOTED EQUIPPED WITH SMOKE ALARMS AS REQUIRED FOR NEW DWELLINGS. MAIN LEVEL BUNDLED STUDS OR 4X MEMBER, MINIMUM UNLESS NOTED OTHERWISE ON PLAN. ALL OTHERWISE. ANY HANGERS REQUIRED AT BEAMS ARE SPECIFIED ON PLAN. I JOIST ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN D1 3'-0" 6'-8" BUNDLED STUDS TO BE CONTINUOUS TO FOUNDATION.6'-8" D2 1 MAIN LEVEL OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM OF 3/4"HANGERS TO BE TOP FLANGE BEARING SIMPSON MIT OR ITS TYPE, UNLESS NOTED D2 6'-0" 6'-8" 6'-8" 1/4" = 1'-0" ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDEROTHERWISE. D3 6'-0" 6'-8" 6'-8" DOOR AND TRANSFER GRILLE ABOVE DOOR. HEAT DETECTION INTERCONNECTION R314.4.1 HEAT DETECTORS AND 7.ALL EXTERIOR WALLS TO BE CONTINUOUSLY SHEATHED PER SHEAR WALL SCHEDULE HEAT ALARMS SHALL BE CONNECTED TO AN ALARM OR A SMOKE ALARM D4 2'-6" 6'-8" 6'-8" 6.BEAMS ARE FLUSH FRAMED WITH JOISTS, UNLESS NOTED OTHERWISE ON DETAILS, OR ON 11-S3.1 “UNBLOCKED W6”, UNLESS NOTED OTHERWISE ON PLAN. PROVIDE WEATHER RESISTANT FIBER CEMENT WALLBOARD UNDER TUB THAT IS INSTALLED IN THE DWELLING. ALARMS THAT ARE INSTALLED FOR D5 2'-8" 6'-8" 6'-8" AND SHOWER ENCLOSURE MATERIALS TO A HEIGHT OF 70" MINIMUM PLANS AS “DB.” DB INDICTES A “DROPPED BEAMTHIS PURPOSE SHALL BE LOCATED IN A HALLWAY, ROOM, OR OTHER” WHICH IS FRAMED BELOW THE FLOOR. D6 2'-6" 6'-8" 6'-8" ABOVE THE DRAIN INLET.WHERE BEAMS ARE NOT SUPPORTED BY HANGERS, SUPPORT IS PER THE STUD AND SHEARLOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION. D7 2'-6" 6'-8" 8.ALL SHEAR WALLS INDICATED ON PLAN TO HAVE (2) BUNDLED STUDS AT WALL ENDS,6'-8" ARLINGTON, WA WALL PLAN. PROVIDE A35 CLIPS EA SIDE OF BEAMS THAT BEAR ON DOUBLE TOP PLATES. D8 2'-6" 6'-8" UNLESS NOTED OTHERWISE ON PLAN. HOLD DOWNS ARE AS INDICATED ON PLAN, AND MAY6'-8" FLOOR PLAN KEY NOTES 309 S DUNHAM AVE ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN COMBINATION ALARMS R314.5 COMBINATION SMOKE AND CARBON NOT BE REQUIRED AT SOME WALLS. OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM ? 3/4" MONOXIDE ALARMS MAY BE USED IN PLACE OF SMOKE ALARMS. D9 6'-0" 6'-8" 6'-8" NO. DESCRIPTION ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER 7.WOOD “I-JOISTS” TO BE DESIGNED BY OTHERS. SUBMITTAL INFORMATION, DESIGN D10 5'-0" 6'-8" 6'-8" 1 EXISTING SEWER ~5' ABOVE FFE DOOR AND TRANSFER GRILLE ABOVE DOOR. CRITERIA, RIM JOIST, AND BLOCKING REQUIREMENTS PER STRUCTURAL GENERAL NOTES.POWER SOURCE R314.6 SMOKE ALARMS, HEAT ALARMS, AND HEAT D11 2'-6" 6'-8" 9.POST BASES AND CAPS, WHERE NECESSARY, ARE INDICATED ON PLAN.6'-8" 2 EXISTING ELECTRICAL PANEL-150 AMP, UPGRADE TO 200 AMP DETECTORS SHALL RECEIVE PRIMARY POWER FROM THE BUILDING D12 5'-0" 6'-8" 6'-8" 1. A CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH WIRING AND, WHEN POWER IS INTERRUPTED, SHALL RECEIVE POWER D22 2'-6" 6'-8" 10.FABRICATE ALL STEEL COLUMNS -¼6'-8" ” PER FLOOR TO ALLOW FOR WOOD SHRINKAGE. SEPARATE SLEEPING AREA IN IMMEDIATE VICINITY OF BEDROOMS 8.ALL RIM JOISTS TO BE 1 ½” LSL MINIMUM, UNLESS OTHERWISE NOTED ON PLAN.FROM A BATTERY. VIRTUS STAMP AND SCOPE 309 S DUNHAM AVE ADDITION AND ON EACH LEVEL PER 2015 IRC R315. DEMO 2'-0" 6'-8" 6'-8" ENCOMPASSES THE PRIMARY 2. A SMOKE DETECTOR SHALL BE INSTALLED IN EACH HABITABLE ROOM.9.BEARING STUD, SHEAR WALL, HOLD-DOWN, POST SIZE, AND POST CAP AND BASEINTERCONNECTIVITY R314.4 WHERE MORE THAN ONE SMOKE ALARM IS DEMO 2'-4" 6'-8" 11.WALL ANCHORAGE AND OTHER TYPICAL WALL FRAMING DETAILS PER SHEETS S-3.0 AND6'-8" 3. A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH REQUIREMENTS BELOW PER STUD AND SHEAR WALL PLAN.REQUIRED TO BE INSTALLED, THE ALARM DEVICES SHALL BE DEMO 5'-0" 6'-8" S-3.1. NOT ALL DETAILS MAY BE APPLICABLE.6'-8" STRUCTURAL ELEMENTS AS SHOWN FLOOR. INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE IN THE REDLINE MARKUPS, ONLY. DEMO 2'-6" 6'-8" 6'-8" 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING DEMO 2'-6" 6'-8" 6'-8" LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER 10.FABRICATE ALL STEEL COLUMNS -1/4” PER FLOOR TO ALLOW FOR WOOD SHRINKAGE.UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL NOT BE PROJECT: SMITH REMODEL PROJECT NUMBER: 24081-0106 THAN 24". REQUIRED WHERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL DEMO 2'-0" 6'-8" 6'-8" 5. SMOKE DETECTORS SHALL BE 110V HARDWIRED, INTERCONNECTED, ALARMS SOUND UPON ACTIVATION OF ONE ALARM. 11.TYPICAL DETAILS PER S-3.2. NOT ALL DETAILS MAY BE APPLICABLE. Job No.: 23-15 WITH BATTERY BACKUP, PER 2015 IRC R314. WHERE AN ACCESSORY DWELLING UNIT IS CREATED WITHIN AN EXISTING DATE: 01/21/2025 NOTE: A SPRINKLER SYSTEM IS NOT REQUIRED FOR THIS RESIDENCE. DWELLING UNIT ALL REQUIRED SMOKE ALARMS, IN THE ACCESSORY DWELLING UNIT AND THE PRIMARY DWELLING UNIT, SHALL BE DESCRIPTION: MAIN LEVEL FRAMING, AND MAIN LEVEL STUD DRAWN BY: CDA INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE AND SHEAR WALL PLANS ALARM WILL ACTIVATE ALL ALARMS IN BOTH THE PRIMARY DWELLING UNIT A2.0 AND THE ACCESSORY DWELLING UNIT _______ - 28'-0 1/2" 14'-0 1/4" 14'-0 1/4" 9 1 - 2 3 4 5 6 7 8 9 _______ --- 1 2 3 4 5 6 7 8 H DIM. TO CL OF POST - _______ I --- G (N)GLULAM BEAM ABV. 39'-1 7/8" COVERED PORCH ADDITION VAULTED CEILING 4/12 SLOPE (N) VENTED CRAWLSPACE (N) FOUNDATION, SEE FDN PLAN GUARDRAILS REQUIRED IF DECK SURFACE MORE THAN 30" ABOVE GRADE - _______ --- WINDER REQUIRED 12'-9 1/4" TO MEET HEADROOM (E) FOUNDATION, SEE FDN PLAN PER CODE-6'-8" MIN. 13'-9 1/4" 14'-3 1/4" NEW ADDITION 9'-4 3/4" 4'-4 1/2" 2'-7 1/4" 4'-7" 4'-7" 2'-6" 4'-1" F DIM. TO F2 F1 FACE OF DIM. TO CONC. 10'-0 3/8" 2'-5 1/2" 6'-8 1/2" 9'-3 3/8" 9'-8 1/8" FACE OF 9'-4 3/4" 4'-4 1/2" D2 CONC. E (E) VENTED CRAWLSPACE H W4 F5 F4 F3 - _______ 3'-0" --- W4 - 4'-0" 2 NEW ADDITION _______ --- = W5 D13 (N) BATH G 4'-3" (N) BEDROOM 3 3'-2 3/4"D21 3'-6" 5'-10 1/4" DW DN CL. (N) STORAGE 5'-9 1/2" (N) DINING EGRESS REMOVE WINDOW D3 9'-0 1/2" = AND FILL IN WITH 11'-4 1/2" F23 FRAMING ALIGN NEW FRAMING CONVERT TO EGRESS WINDOW STAIRS: W4 TO CORNER (E) WALL SILL AT +44" A.F.F. MAX. 14RISERS 3'-9 3/4" (N) KITCHEN AT 7" 2X4 INTERIOR WALL, TYP. VAULTED CEILING 4/12 SLOPE REMOVE SIDING 13'-3 7/8" WH 1/2" AIR GAP FROM CONCRETE ON EXT. WALL 5'-6 1/4" S LINEN S 12'-0" 2'-0" W3 F22 13'-0 1/8" STAIR OPENING Range D18 D17 D16 5'-10" 3'-6 5/8" 7'-8 3/8" FULL HEIGHT WALL6x6 ON TOP OF F 3'-10" D19 D15 STUB FOR GLULAM. SIMPSON6'-4 7/8" S/CM 7'-9 1/8" STAIR OPENING FUTURE SINK 1 (E) WIN. COULD REMAIN 24'-0" GRINDER BC60 HALF BASE 3'-11 5/8" (N) MECH. 2'-9 7/8" PUMP STORAGE CL VANITY ABV. ISLAND 10' X 5' S PANTRY (E) MASTER BEDROOM CLOSET 7'-10 1/8" D DBL OvenOVEN E 28'-0" ALIGN 8'-1 1/4" D14 CL TOILET ABV. GL 5 1/2" x 16" 3'-6 5/8" ALIGN WALL ON CENTER W/POST - SIMPSON BA FLUSH INSIDE FACE OF WALL _______ 9'-0 5/8" 28'-0" EXISTING BASEMENT OF POST 7'-2" --- (N) SKYLIGHT OVER THE STAIRS TO INSIDE FACE OF BEAM HANGER (N)GLULAM 2'-0" C BEAM ABV. (E) DOOR OPENING Refrigerator CL SHOWER DRAIN ABV. 4x4 POST ABOVE ALTER AS NEEDED PER DOOR CL VANITY ABV. 2x8 @ 24" OC 8'-10 1/8" WINDOW HEADER W3 LOCATE WITHIN 3' OF PEAK D9 SELECTION F21 F24 W5 D20 SISTERED TO (E) 2x6 CL WASHER ABV. EGRESS Copyright 2020 Sno Valley Cottages, LLC All rights reserved. (N)6X6 POST-BEARING TO CABINETS/COUNTER 3'-3 1/2" 2'-10 1/4" 4'-0 1/8" 2'-4" 2'-6" (N) OFFICE (N) BONUS ROOM 4'-0" F6 (N) WALL BELOW TO FTG. 6'-1 3/8" GL 5 1/2" x 10 1/2" W1 No. Date 9'-4 3/4" F25 6x6 ON TOP OF 2'-1 1/2" CL TOILET ABV. 3'-4 1/2" S GLULAM. SIMPSON (N) BATHROOM 13'-6" TO CL OF (E) BEAM AND POSTS BC60 HALF BASE D8 CL. = B MATCH CL PLUMBING WALL ABV. DIM. TO = D10 CL SHOWER DRAIN ABV. 2'-11" WALL AT +42" A.F.F. D7 FACE OF 15'-8 1/2" W6 SIMPSON HUC 66" VANITY 5'-11 1/4" 4'-0" CONC. DN 4'-9" = 5'-4" 15'-11 1/4" TO STAIR OPENING HANGER CLOSET 3'-10 7/8" 1'-4" MIRROR DIM. ON FIREPLACE CENTER 7'-9 1/8" = CONFIRM RO WITH POCKET DOOR SPECS (2)2X NOT FOR CONSTRUCTIONFIREPLACE D11 4x8 3 1/2" 3'-3 1/2" SHOWER/TOILET D A MATCH (N) GREAT ROOM6x6 ON TOP OF = FLAT CEILING AT 7' 10-3/4" 4x4 POST ABOVEEXISTING RESIDENCE GLULAM. SIMPSON F20 4'-0" 2'-0" WINDOW HEADERMIRROR DIM. ON FIREPLACE CENTER REBUILD FP AT INTERIOR BC60 HALF BASE(N)6x6 POST-BEARING TO METAL RAILING 3'-1" 3'-8 1/4"S/CM SHOWER 4'-3 1/2" F7 AT +36" A.F.F. 4' W X 3' D = Issue Date TO CENTER BEAM BELOW C - ON BEAMS ABV. AND STAIR D4 D5 _______ --- S ADD 2' X 2' SKYLIGHT ABOVE F8 7'-6" 9'-0 1/2" 30'-1 3/8" W1 (N) GLULAM BEAM ABV. 42" VANITY 4'-9 7/8" (N) BEDROOM 2 F19 Author F9 4'-2 1/2"4'-2 1/2" 3'-4 1/2"(N) BATH W2 1'-0" Drawn by: D12 5'-0" BENCH/CUBBIES/CABS 9'-7 5/8" B 2 BASEMENT LEVEL 7'-6" GL 5 1/2" x 10 1/2" W3 F18 1/4" = 1'-0" 6'-2 7/8" 1'-4 3/8"1'-4 3/8" CLOSET F10 F11 F12 1'-3 1/2" 4'-5 1/2"2'-10" 2'-2" 2'-4 1/2" 6'-7 7/8" 6'-7 7/8" 4'-9 7/8" REMODEL/ADDITION FLOOR PLANS 3'-1 3/8" ROOF FRAMING PLAN NOTES: EGRESS Scale: FLOOR PLAN NOTES D1 As indicated SMOKE ALARMS AND HEAT DETECTION 1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0, A FRAMING: 2X6 EXTERIOR WALLS REQUIRED LOCATIONS R314.3: S-1.1, AND S-1.2.FRAMING - DOOR SCH. 1'-6" 3'-0" 7'-6" SMOKE ALARMS/CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN: 2X4/6's AT INTERIOR WALLS UNLESS NOTED OTHERWISE 1. IN EACH SLEEPING ROOM OR SLEEPING LOFT NO. DOOR SIZE HEAD HEIGHT COMMENTS F13 F14 F15 F16 F17 FILL IN 2X4 FRAMING 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE 2.ALL DUCTS CHASES AND PIPES SHALL BE PER MECHANICAL, PLUMBING, ELECTRICAL AND BASEMENT FF AT ALL MODIFIED SEE STRUCTURAL NOTES FOR STUD SCHEDULE. VICINITY OF THE BEDROOMS. D13 2'-6" 6'-8"SPRINKLER DRAWINGS. 6'-8" COVERED WINDOW OPENINGS 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING CONCEALED SPACES SHALL BE FIRESTOPPED IN BOTH DIRECTIONS AT BASEMENTS AND HABITABLE ATTICS. D14 2'-10" 6'-8" 6'-8" NEW ADDITION - PORCH 10" ON CENTER AND AT FLOORS. TYPICAL. 4. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET FROM D15 2'-6" 6'-8"3.ROOF SHEATHING PER PLAN AND STUCTURAL GENERAL NOTES. SHEATHING TO BE NAILED6'-8" _______ --- THE DOOR OR OPENING OF A BATHROOM. D16 2'-4" 6'-8"TO ROOF FRAMING WITH 8d X 2 ½6'-8" ” COMMON WIRE NAILS @ 6” OC AT SUPPORTED PANEL ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH D17 1'-8" 6'-8"EDGES, AND 126'-8" ” OC FIELD NAILING. LAY SHEATHING THE LONG DIRECTION PERPENDICULAR DN HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. THE LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER TO SUPPORTS AND STAGGER PANEL END JOINTS. ALLOW 1/8” SPACE BETWEEN PANEL ENDS D18 2'-6" 6'-8" 6'-8" MINIMUM CLEAR OPENING HEIGHT DIMENSION SHALL BE 24". MINIMUM THAN 24". CLEAR OPENING WIDTH DIMENSION SHALL BE 20". SILL HEIGHT SHALL D19 2'-6" 6'-8"AND EDGES.6'-8" NOT BE MORE THAN 44" ABOVE THE FLOOR. ALTERATIONS, REPAIRS AND ADDITIONS R314.2.2 WHERE ALTERATIONS, D20 2'-6" 6'-8" 6'-8" REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHERE ONE OR D21 5'-0" 6'-8"4.ALL 2X HANGERS TO BE TOP FLANGE BEARING SIMPSON JB TYPE, UNLESS NOTED6'-8" SHOWER COMPARTMENTS AND WALLS AROUND BATHTUBS WITH MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DEMO 2'-6" 6'-8"OTHERWISE. ANY HANGERS REQUIRED AT BEAMS ARE SPECIFIED ON PLAN. I JOIST6'-8" SHOWERS SHALL BE FINISHED WITH A SMOOTH NON-ABSORBANT DWELLINGS, OR WHERE AN ACCESSORY DWELLING UNIT IS CREATED DEMO 2'-6" 6'-8"HANGERS TO BE TOP FLANGE BEARING SIMPSON MIT OR ITS TYPE, UNLESS NOTED6'-8" SURFACE TO NOT LESS THAN 72" ABOVE THE FLOOR (IRC R307.2). WITHIN AN EXISTING DWELLING UNIT, EACH DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS AS REQUIRED FOR NEW DWELLINGS. MAIN LEVEL OTHERWISE. ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN D1 3'-0" 6'-8" 6'-8" D2 1 MAIN LEVEL OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM OF 3/4" D2 6'-0" 6'-8"5.BEAMS ARE FLUSH FRAMED WITH JOISTS, UNLESS NOTED OTHERWISE ON DETAILS, OR ON6'-8" 1/4" = 1'-0" ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER DOOR AND TRANSFER GRILLE ABOVE DOOR. HEAT DETECTION INTERCONNECTION R314.4.1 HEAT DETECTORS AND D3 6'-0" 6'-8"PLANS AS 6'-8"“DB.” DB INDICTES A “DROPPED BEAM” WHICH IS FRAMED BELOW THE FLOOR. HEAT ALARMS SHALL BE CONNECTED TO AN ALARM OR A SMOKE ALARM D4 2'-6" 6'-8"WHERE BEAMS ARE NOT SUPPORTED BY HANGERS, SUPPORT IS PER THE STUD AND SHEAR6'-8" PROVIDE WEATHER RESISTANT FIBER CEMENT WALLBOARD UNDER TUB THAT IS INSTALLED IN THE DWELLING. ALARMS THAT ARE INSTALLED FOR D5 2'-8" 6'-8"WALL PLAN. PROVIDE A35 CLIPS EA SIDE OF BEAMS THAT BEAR ON DOUBLE TOP PLATES.6'-8" AND SHOWER ENCLOSURE MATERIALS TO A HEIGHT OF 70" MINIMUM THIS PURPOSE SHALL BE LOCATED IN A HALLWAY, ROOM, OR OTHER D6 2'-6" 6'-8" 6'-8" ABOVE THE DRAIN INLET. LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION. D7 2'-6" 6'-8"6.PROVIDE SIMPSON STRONG TIE H2.5A TIES AT ALL ROOF TRUSSES6'-8" FLOOR PLAN KEY NOTES ARLINGTON, WA D8 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN COMBINATION ALARMS R314.5 COMBINATION SMOKE AND CARBON OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM ? 3/4" MONOXIDE ALARMS MAY BE USED IN PLACE OF SMOKE ALARMS. D9 6'-0" 6'-8"7.WHERE SHEAR WALLS ARE PERPENDUCLAR TO ROOF TRUSSES, PROVIDE 2X BLOCKING6'-8" NO. DESCRIPTION ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D10 5'-0" 6'-8" 6'-8" 1 EXISTING SEWER ~5' ABOVE FFE BETWEEN ROOF TRUSSES WITH SIMPSON STRONG TIE A35 CLIPS @ 24” OC INTO THE DOOR AND TRANSFER GRILLE ABOVE DOOR. POWER SOURCE R314.6 SMOKE ALARMS, HEAT ALARMS, AND HEAT D11 2'-6" 6'-8" 6'-8" 2 EXISTING ELECTRICAL PANEL-150 AMP, UPGRADE TO 200 AMP DETECTORS SHALL RECEIVE PRIMARY POWER FROM THE BUILDING DOUBLE PLATE. WHERE SHEAR WALLS ARE PARALLEL, ALIGN TRUSS OVER SHEAR WALL, D12 5'-0" 6'-8" 6'-8" 1. A CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH WIRING AND, WHEN POWER IS INTERRUPTED, SHALL RECEIVE POWER AND PROVIDE CONNECTION PER SHEAR WALL SCHEDULE. SEPARATE SLEEPING AREA IN IMMEDIATE VICINITY OF BEDROOMS D22 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ADDITION FROM A BATTERY. VIRTUS STAMP AND SCOPE AND ON EACH LEVEL PER 2015 IRC R315. DEMO 2'-0" 6'-8" 6'-8" 8.ALL RIM JOISTS TO BE 1 ½” LSL MINIMUM, UNLESS OTHERWISE NOTED ON PLAN. ENCOMPASSES THE PRIMARY 2. A SMOKE DETECTOR SHALL BE INSTALLED IN EACH HABITABLE ROOM. INTERCONNECTIVITY R314.4 WHERE MORE THAN ONE SMOKE ALARM IS DEMO 2'-4" 6'-8" 6'-8" 3. A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH REQUIRED TO BE INSTALLED, THE ALARM DEVICES SHALL BE DEMO 5'-0" 6'-8" 6'-8" STRUCTURAL ELEMENTS AS SHOWN FLOOR. INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE DEMO 2'-6" 6'-8"9.ADDITIONAL TYPICAL DETAILS NOT CALLED OUT ON PLAN PER SHEET S-4.0. NOT ALL6'-8" IN THE REDLINE MARKUPS, ONLY. 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING DETAILS MAY BE APPLICABLE. DEMO 2'-6" 6'-8" 6'-8" LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL NOT BE PROJECT: SMITH REMODEL PROJECT NUMBER: 24081-0106 THAN 24". REQUIRED WHERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL DEMO 2'-0" 6'-8" 6'-8" 5. SMOKE DETECTORS SHALL BE 110V HARDWIRED, INTERCONNECTED, ALARMS SOUND UPON ACTIVATION OF ONE ALARM. Job No.: 23-15 WITH BATTERY BACKUP, PER 2015 IRC R314. WHERE AN ACCESSORY DWELLING UNIT IS CREATED WITHIN AN EXISTING DATE: 01/21/2025 NOTE: A SPRINKLER SYSTEM IS NOT REQUIRED FOR THIS RESIDENCE. DWELLING UNIT ALL REQUIRED SMOKE ALARMS, IN THE ACCESSORY DWELLING UNIT AND THE PRIMARY DWELLING UNIT, SHALL BE DESCRIPTION: CEILING SOFFIT FRAMING PLAN DRAWN BY: CDA INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL ALARMS IN BOTH THE PRIMARY DWELLING UNIT A2.0 AND THE ACCESSORY DWELLING UNIT _______ - 28'-0 1/2" 8 14'-0 1/4" 14'-0 1/4" 9 1 - 2 3 4 5 6 7 8 9 S-4.0 _______ --- 1 2 3 4 5 6 7 8 H DIM. TO CL OF POST - _______ I --- G (N)GLULAM BEAM ABV. 39'-1 7/8" COVERED PORCH ADDITION (N) FOUNDATION, SEE FDN PLAN 2x10 @ 24" OCVAULTED CEILING 4/12 SLOPE 2x10 @ 24" OC GUARDRAILS REQUIRED IF DECK SURFACE (N) VENTED CRAWLSPACE MORE THAN 30" ABOVE GRADE - _______ --- WINDER REQUIRED 12'-9 1/4" TO MEET HEADROOM (E) FOUNDATION, SEE FDN PLAN PER CODE-6'-8" MIN. 13'-9 1/4" 14'-3 1/4" NEW ADDITION 9'-4 3/4" 4'-4 1/2" 2'-7 1/4" 4'-7" 4'-7" 2'-6" 4'-1" F (DROPPED) DIM. TO F2 F1 GL 5 1/2" x 10 1/2" FACE OF DIM. TO CONC. 10'-0 3/8" 2'-5 1/2" 6'-8 1/2" 9'-3 3/8" 9'-8 1/8" FACE OF (DROPPED)9'-4 3/4" 4'-4 1/2" D2 CONC. E GL 5 1/2" x 10 1/2" H (E) VENTED CRAWLSPACE W4 F5 F4 F3 - _______ 3'-0" --- W4 - 4'-0" 2 NEW ADDITION _______ --- = W5 D13 (N) BATH 12 G 4'-3" (N) BEDROOM 3 3'-2 3/4"D21 3'-6" 5'-10 1/4" DW S-4.0DN CL. (N) STORAGE 5'-9 1/2" (N) DINING TYPICAL AT NEW EGRESS REMOVE WINDOW CONSTRUCTION, UNLESS D3 9'-0 1/2" F23 = AND FILL IN WITH NOTED OTHERWISE 11'-4 1/2" FRAMING ALIGN NEW FRAMING CONVERT TO EGRESS WINDOW STAIRS: W4 GL 5 1/2" x 10 1/2" RIDGE BEAMTO CORNER (E) WALL SILL AT +44" A.F.F. MAX. 14RISERS 3'-9 3/4" (N) KITCHEN AT 7" 2X4 INTERIOR WALL, TYP. VAULTED CEILING 4/12 SLOPE 6 REMOVE SIDING 13'-3 7/8" WH 1/2" AIR GAP FROM CONCRETE ON EXT. WALL 5'-6 1/4" S LINEN S 12'-0" 2'-0" S-4.0 W3 F22 13'-0 1/8" STAIR OPENING Range D18 D17 D16 5'-10" 3'-6 5/8" 7'-8 3/8" FULL HEIGHT WALL F 3'-10" D19 D15 STUB FOR 6'-4 7/8" S/CM 7'-9 1/8" STAIR OPENING FUTURE SINK 1 (E) WIN. COULD REMAIN 24'-0" 3'-11 5/8" GRINDER (N) MECH. 2'-9 7/8" PUMP STORAGE CL VANITY ABV. ISLAND 10' X 5' S PANTRY (E) MASTER BEDROOM CLOSET 7'-10 1/8" D DBL OvenOVEN E 28'-0" ALIGN 8'-1 1/4" D14 CL TOILET ABV. 3'-6 5/8" ALIGN WALL ON CENTER W/POST - FLUSH INSIDE FACE OF WALL _______ 9'-0 5/8" 28'-0" EXISTING BASEMENT OF POST 7'-2" --- (N) SKYLIGHT OVER THE STAIRS TO INSIDE FACE OF BEAM (N)GLULAM 2'-0" C BEAM ABV. 6'-0" Refrigerator (E) DOOR OPENING CL SHOWER DRAIN ABV. ALTER AS NEEDED PER DOOR CL VANITY ABV. 8'-10 1/8" W3 LOCATE WITHIN 3' OF PEAK D9 SELECTION F21 F24 W5 D20 CL WASHER ABV. GL 5 1/2" x 10 1/2" EGRESS Copyright 2020 Sno Valley Cottages, LLC All rights reserved. (N)6X6 POST-BEARING TO CABINETS/COUNTER 3'-3 1/2" 2'-10 1/4" 4'-0 1/8" 2'-4" 2'-6" (N) OFFICE (N) BONUS ROOM (DROPPED) 4'-0" F6 (N) WALL BELOW TO FTG. 6'-1 3/8" W1 No. Date 9'-4 3/4" F25 2'-1 1/2" CL TOILET ABV. 3'-4 1/2" S 10 (N) BATHROOM 13'-6" TO CL OF (E) BEAM AND POSTS D8 CL. = B S-4.0MATCH CL PLUMBING WALL ABV. DIM. TO = D10 CL SHOWER DRAIN ABV. 2'-11" WALL AT +42" A.F.F. D7 FACE OF 15'-8 1/2" (E) 2x4 @ 24" OC 5'-11 1/4" W6 66" VANITY 4'-0" CONC. DN 4'-9" = 5'-4" 15'-11 1/4" TO STAIR OPENING CLOSET 3'-10 7/8" 1'-4" MIRROR DIM. ON FIREPLACE CENTER 7'-9 1/8" = CONFIRM RO WITH POCKET DOOR SPECS (2)2X NOT FOR CONSTRUCTIONFIREPLACE D11 3 1/2" D 3'-3 1/2" SHOWER/TOILET A MATCH (N) GREAT ROOM = FLAT CEILING AT 7' 10-3/4" EXISTING RESIDENCE F20 4'-0" 2'-0" MIRROR DIM. ON FIREPLACE CENTER REBUILD FP AT INTERIOR (N)6x6 POST-BEARING TO METAL RAILING 3'-1" 3'-8 1/4"S/CM SHOWER 4'-3 1/2" F7 AT +36" A.F.F. 4' W X 3' D = Issue Date TO CENTER BEAM BELOW C - ON BEAMS ABV. AND STAIRGL 5 1/2" x 10 1/2" D4 D5 _______ --- (DROPPED) S ADD 2' X 2' SKYLIGHT ABOVE F8 7'-6" 9'-0 1/2" 30'-1 3/8" 10 W1 (N) GLULAM BEAM ABV. 42" VANITY 4'-9 7/8" S-4.0 6'-0" (N) BEDROOM 2 F19 Author F9 4'-2 1/2"4'-2 1/2" 3'-4 1/2"(N) BATH W2 1'-0" Drawn by: D12 5'-0" (E) 2x4 @ 24" OC BENCH/CUBBIES/CABS 9'-7 5/8" B 2 BASEMENT LEVEL 7'-6" W3 F18 1/4" = 1'-0" 6'-2 7/8" 1'-4 3/8"1'-4 3/8" CLOSET F10 F11 F12 1'-3 1/2" 4'-5 1/2"2'-10" 2'-2" 2'-4 1/2" 6'-7 7/8" 6'-7 7/8" 4'-9 7/8" REMODEL/ADDITION FLOOR PLANS 3'-1 3/8" EGRESS Scale: FLOOR PLAN NOTES D1 As indicated SMOKE ALARMS AND HEAT DETECTION A FRAMING: 2X6 EXTERIOR WALLS REQUIRED LOCATIONS R314.3: FRAMING - DOOR SCH. 1'-6" 3'-0" 7'-6" SMOKE ALARMS/CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN: 2x10 @ 24" OC 2X4/6's AT INTERIOR WALLS UNLESS NOTED OTHERWISE 1. IN EACH SLEEPING ROOM OR SLEEPING LOFT NO. DOOR SIZE HEAD HEIGHT COMMENTS F13 4x12 F14 F15 F16 F17 FILL IN 2X4 FRAMING 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE BASEMENT FF AT ALL MODIFIED SEE STRUCTURAL NOTES FOR STUD SCHEDULE. VICINITY OF THE BEDROOMS. D13 2'-6" 6'-8" 6'-8" COVERED WINDOW OPENINGS 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING ROOF FRAMING PLAN NOTES: CONCEALED SPACES SHALL BE FIRESTOPPED IN BOTH DIRECTIONS AT BASEMENTS AND HABITABLE ATTICS. D14 2'-10" 6'-8" 6'-8" NEW ADDITION - PORCH 1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0,_______ 4x10 4x10 10" ON CENTER AND AT FLOORS. TYPICAL. 4. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET FROM D15 2'-6" 6'-8" 6'-8" --- 2x10 @ 24" OC THE DOOR OR OPENING OF A BATHROOM. D16 2'-4" 6'-8"S-1.1, AND S-1.2.6'-8" ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH D17 1'-8" 6'-8" 6'-8" 4x12DN HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. THE LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER 2.ALL DUCTS CHASES AND PIPES SHALL BE PER MECHANICAL, PLUMBING, ELECTRICAL AND D18 2'-6" 6'-8" 6'-8" MINIMUM CLEAR OPENING HEIGHT DIMENSION SHALL BE 24". MINIMUM THAN 24". CLEAR OPENING WIDTH DIMENSION SHALL BE 20". SILL HEIGHT SHALL D19 2'-6" 6'-8"SPRINKLER DRAWINGS. 6'-8" NOT BE MORE THAN 44" ABOVE THE FLOOR. ALTERATIONS, REPAIRS AND ADDITIONS R314.2.2 WHERE ALTERATIONS, D20 2'-6" 6'-8" 6'-8" REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHERE ONE OR D21 5'-0" 6'-8"3.ROOF SHEATHING PER PLAN AND STUCTURAL GENERAL NOTES. SHEATHING TO BE NAILED6'-8" 8 SHOWER COMPARTMENTS AND WALLS AROUND BATHTUBS WITH MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DEMO 2'-6" 6'-8"TO ROOF FRAMING WITH 8d X 2 ½6'-8" ” COMMON WIRE NAILS @ 6” OC AT SUPPORTED PANEL S-4.0 SHOWERS SHALL BE FINISHED WITH A SMOOTH NON-ABSORBANT DWELLINGS, OR WHERE AN ACCESSORY DWELLING UNIT IS CREATED SURFACE TO NOT LESS THAN 72" ABOVE THE FLOOR (IRC R307.2). WITHIN AN EXISTING DWELLING UNIT, EACH DWELLING UNIT SHALL BE DEMO 2'-6" 6'-8"EDGES, AND 126'-8" ” OC FIELD NAILING. LAY SHEATHING THE LONG DIRECTION PERPENDICULAR EQUIPPED WITH SMOKE ALARMS AS REQUIRED FOR NEW DWELLINGS. MAIN LEVELTO SUPPORTS AND STAGGER PANEL END JOINTS. ALLOW 1/8” SPACE BETWEEN PANEL ENDS ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN D1 3'-0" 6'-8"AND EDGES.6'-8" D2 1 MAIN LEVEL OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM OF 3/4" D2 6'-0" 6'-8" 6'-8" 1/4" = 1'-0" ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D3 6'-0" 6'-8"4.ALL 2X HANGERS TO BE TOP FLANGE BEARING SIMPSON JB TYPE, UNLESS NOTED6'-8" DOOR AND TRANSFER GRILLE ABOVE DOOR. HEAT DETECTION INTERCONNECTION R314.4.1 HEAT DETECTORS AND HEAT ALARMS SHALL BE CONNECTED TO AN ALARM OR A SMOKE ALARM D4 2'-6" 6'-8"OTHERWISE. ANY HANGERS REQUIRED AT BEAMS ARE SPECIFIED ON PLAN. I JOIST6'-8" PROVIDE WEATHER RESISTANT FIBER CEMENT WALLBOARD UNDER TUB THAT IS INSTALLED IN THE DWELLING. ALARMS THAT ARE INSTALLED FOR D5 2'-8" 6'-8"HANGERS TO BE TOP FLANGE BEARING SIMPSON MIT OR ITS TYPE, UNLESS NOTED6'-8" AND SHOWER ENCLOSURE MATERIALS TO A HEIGHT OF 70" MINIMUM THIS PURPOSE SHALL BE LOCATED IN A HALLWAY, ROOM, OR OTHER D6 2'-6" 6'-8" 6'-8" ABOVE THE DRAIN INLET. LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION. OTHERWISE. D7 2'-6" 6'-8" 6'-8" FLOOR PLAN KEY NOTES ARLINGTON, WA D8 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN COMBINATION ALARMS R314.5 COMBINATION SMOKE AND CARBON 5.BEAMS ARE FLUSH FRAMED WITH JOISTS, UNLESS NOTED OTHERWISE ON DETAILS, OR ON OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM ? 3/4" MONOXIDE ALARMS MAY BE USED IN PLACE OF SMOKE ALARMS. D9 6'-0" 6'-8" 6'-8" NO. DESCRIPTION PLANS AS “DB.” DB INDICTES A “DROPPED BEAM” WHICH IS FRAMED BELOW THE FLOOR. ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D10 5'-0" 6'-8" 6'-8" 1 EXISTING SEWER ~5' ABOVE FFE DOOR AND TRANSFER GRILLE ABOVE DOOR. POWER SOURCE R314.6 SMOKE ALARMS, HEAT ALARMS, AND HEAT D11 2'-6" 6'-8"WHERE BEAMS ARE NOT SUPPORTED BY HANGERS, SUPPORT IS PER THE STUD AND SHEAR6'-8" 2 EXISTING ELECTRICAL PANEL-150 AMP, UPGRADE TO 200 AMP DETECTORS SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WALL PLAN. PROVIDE A35 CLIPS EA SIDE OF BEAMS THAT BEAR ON DOUBLE TOP PLATES. D12 5'-0" 6'-8" 6'-8" 1. A CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH WIRING AND, WHEN POWER IS INTERRUPTED, SHALL RECEIVE POWER SEPARATE SLEEPING AREA IN IMMEDIATE VICINITY OF BEDROOMS D22 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ADDITION FROM A BATTERY. 6.PROVIDE SIMPSON STRONG TIE H2.5A TIES AT ALL ROOF TRUSSES VIRTUS STAMP AND SCOPE AND ON EACH LEVEL PER 2015 IRC R315. DEMO 2'-0" 6'-8" 6'-8" ENCOMPASSES THE PRIMARY 2. A SMOKE DETECTOR SHALL BE INSTALLED IN EACH HABITABLE ROOM. INTERCONNECTIVITY R314.4 WHERE MORE THAN ONE SMOKE ALARM IS DEMO 2'-4" 6'-8" 6'-8" 3. A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH REQUIRED TO BE INSTALLED, THE ALARM DEVICES SHALL BE DEMO 5'-0" 6'-8"7.WHERE SHEAR WALLS ARE PERPENDUCLAR TO ROOF TRUSSES, PROVIDE 2X BLOCKING6'-8" STRUCTURAL ELEMENTS AS SHOWN FLOOR. INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE DEMO 2'-6" 6'-8"BETWEEN ROOF TRUSSES WITH SIMPSON STRONG TIE A35 CLIPS @ 246'-8" ” OC INTO THE IN THE REDLINE MARKUPS, ONLY. 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING DOUBLE PLATE. WHERE SHEAR WALLS ARE PARALLEL, ALIGN TRUSS OVER SHEAR WALL, DEMO 2'-6" 6'-8" 6'-8" LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL NOT BE PROJECT: SMITH REMODEL PROJECT NUMBER: 24081-0106 THAN 24". REQUIRED WHERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL DEMO 2'-0" 6'-8"AND PROVIDE CONNECTION PER SHEAR WALL SCHEDULE.6'-8" 5. SMOKE DETECTORS SHALL BE 110V HARDWIRED, INTERCONNECTED, ALARMS SOUND UPON ACTIVATION OF ONE ALARM. Job No.: 23-15 WITH BATTERY BACKUP, PER 2015 IRC R314. WHERE AN ACCESSORY DWELLING UNIT IS CREATED WITHIN AN EXISTING 8.ALL RIM JOISTS TO BE 1 ½” LSL MINIMUM, UNLESS OTHERWISE NOTED ON PLAN. DATE: 01/21/2025 NOTE: A SPRINKLER SYSTEM IS NOT REQUIRED FOR THIS RESIDENCE. DWELLING UNIT ALL REQUIRED SMOKE ALARMS, IN THE ACCESSORY DWELLING UNIT AND THE PRIMARY DWELLING UNIT, SHALL BE 9.ADDITIONAL TYPICAL DETAILS NOT CALLED OUT ON PLAN PER SHEET S-4.0. NOT ALL DESCRIPTION: ROOF FRAMING PLAN DRAWN BY: CDA INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL ALARMS IN BOTH THE PRIMARY DWELLING UNIT DETAILS MAY BE APPLICABLE. A2.0 AND THE ACCESSORY DWELLING UNIT GENERAL REQUIREMENTS STRUCTURAL OBSERVATION FILL MATERIAL PENETRATION SLEEVES STRUCTURAL OBSERVATION IS THE VISUAL OBSERVATION OF THE STRUCTURAL COMPACTED FILL MATERIAL SHALL BE PLACED IN MAXIMUM 12" LIFTS AND PROVIDE SLEEVES FOR ALL UTILITY OPENINGS. DO NOT CUT ANY REINFORCING GOVERNING CODE SYSTEM BY A REGISTERED DESIGN PROFESSIONAL FOR GENERAL SHALL BE COMPACTED TO MINIMUM 95% MODIFIED PROCTOR IN ACCORDANCE AT OPENINGS. CONCRETE WHICH HAS CONTAINED WATER FOR MORE THAN 90 THE DESIGN AND CONSTRUCTION OF THIS PROJECT IS GOVERNED BY THE CONFORMANCE TO THE APPROVED CONSTRUCTION DOCUMENTS. PER IBC WITH ASTM D1557. COMPACTION SHALL BE VERIFIED BY A QUALIFIED MINUTES (60 MINUTES IF AIR TEMPERATURE EXCEEDS 85 DEGREES) SHALL NOT INTERNATIONAL BUILDING CODE (IBC) 2021 EDITION, HEREAFTER REFERRED SECTION 1704.6 STRUCTURAL OBSERVATION IS NOT REQUIRED FOR THIS INSPECTOR APPROVED BY THE BUILDING OFFICIAL. BE USED. RETEMPERING OF CONCRETE AFTER INITIAL SET IS NOT ALLOWED. TO AS THE IBC, AS ADOPTED AND MODIFIED BY ARLINGTON, WA UNDERSTOOD PROJECT. HOWEVER, THIS DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY CURE EXPOSED CONCRETE PER ACI 301 FOR A MINIMUM OF 7 DAYS. FOR THE SPECIAL INSPECTIONS AND TESTS REQUIRED BY A SPECIAL INSPECTOR TO BE THE AUTHORITY HAVING JURISDICTION (AHJ). DRAINAGE PER IBC CHAPTER 17. PROVIDE POSITIVE DRAINAGE SLOPES, BOTH DURING AND AFTER CONSTRUCTION JOINTS REFERENCE STANDARDS CONSTRUCTION, FOR SURFACE AND ROOF RUNOFF. CONFORM TO ACI301 SECTION 2.2.2.5, 5.2.2.1, AND 5.3.2.6. SUBMIT LOCATIONS OF AT THE ENGINEERS DISCRETION, SITE OBSERVATIONS MAY STILL BE REFER TO CHAPTER 35 OF THE IBC. WHERE OTHER STANDARDS ARE NOTED IN CONSTRUCTION JOINTS PER ACI301 SECTION 5.1.2.3a FOR REVIEW AND APPROVAL PERFORMED. ONLY SIGNIFICANT STAGES OF CONSTRUCTION IDENTIFIED BY THE THE DRAWINGS, USE THE LATEST EDITION OF THE STANDARD UNLESS A BASEMENT WALLS BY THE STRUCTURAL ENGINEER OF RECORD TWO WEEKS MINIMUM PRIOR TO STRUCTURAL OBSERVER REQUIRE OBSERVATION. FOR REPETITIVE OR SIMILAR SPECIFIC DATE IS INDICATED. REFERENCE TO A SPECIFIC SECTION IN A CODE FORMING. STRUCTURAL ELEMENTS IDENTIFIED AS SIGNIFICANT, ONLY THE FIRST ELEMENT DO NOT BACKFILL AGAINST BASEMENT OR RESTRAINED WALLS UNTIL FRAMING DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE ENTIRE OF A STAGE REQUIRES OBSERVATION UNLESS NOTED OTHERWISE. TO SUPPORT WALL IS PERMANENTLY ATTACHED. DO NOT EXCEED 1'-0" STANDARD. DIFFERENTIAL IN FILL LEVEL ON OPPOSITE SIDES OF FOUNDATION WALLS. EMBEDDED ITEMS POSITION AND SECURE IN PLACE EXPANSION JOINT MATERIAL, ANCHORS AND CONSTRUCTION DOCUMENTS THE STRUCTURAL CONSTRUCTION DOCUMENTS REPRESENT THE FINISHED DESIGN CRITERIA DIVISION OF RESPONSIBILITY OTHER STRUCTURAL AND NON STRUCTURAL EMBEDDED ITEMS BEFORE PLACING CONCRETE. CONTRACTOR SHALL REFER TO MECHANICAL, STRUCTURE. THEY DO NOT INDICATE THE METHOD OR SEQUENCE OF THE STRUCTURAL ENGINEER IS NOT RESPONSIBLE FOR ANY GEOTECHNICAL ELECTRICAL, PLUMBING AND ARCHITECTURAL DRAWINGS AND COORDINATE CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND PROVIDE 1. BUILDING RISK CATEGORY II. ASPECTS OF THIS PROJECT. IT IS RECOMMENDED THAT THE OWNER RETAIN A OTHER EMBEDDED ITEMS. ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING REGISTERED GEOTECHNICAL ENGINEER TO CONDUCT A GEOTECHNICAL CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, 2. FLOOR LIVE LOAD = 40 PSF (REDUCIBLE). INVESTIGATION AND PREPARE A REPORT WITH RECOMMENDATIONS FOR BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. THE FOUNDATION DESIGN AND EARTHWORK PROCEDURES. GROUT STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S USE 7000 PSI NOON SHRINK GROUT UNDER COLUMN BASE PLATES. 3. ROOF LIVE LOAD = 20 PSF MEANS, METHODS, TECHNIQUES, SEQUENCES FOR PROCEDURE OF EXTERIOR SLABS AND SIDEWALKS CONSTRUCTION, OR THE SAFETY PRECAUTIONS AND THE PROGRAMS INCIDENT SEE ARCHITECTURAL/CIVIL DRAWINGS FOR EXTERIOR SLABS AND SIDEWALKS. BONDING AGENT THERETO (NOR SHALL OBSERVATION VISITS TO THE SITE INCLUDE INSPECTION 4.SUPERIMPOSED DEAD LOAD ON ROOF JOISTS = 20 PSF USE MATEREMACO ADH326. APPLY IN ACCORDANCE WITH MANUFACTURER OF THESE ITEMS). THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN INSTRUCTIONS. AND IMPLEMENTATION OF ALL SCAFFOLDING, BRACING AND SHORING. 5. GROUND SNOW LOAD = 25 PSF, Ce=1.0, Is=1.0, Ct=1.2, C = 1.0 FLAT ROOF SNOW S LOAD = 21 PSF. SLOPED ROOF SNOW LOAD = 21 PSF CONCRETE CONSTRUCTION MATERIAL STORAGE CONCRETE CRACK REPAIR AND MAINTENANCE PROGRAM CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONCRETE SHRINKS AND CONTINUES TO SHRINK FOR UP TO TWO YEARS AFTER 6. ULTIMATE WIND SPEED = 98 MPH (3-SECOND GUST), RISK CATEGORY II, STANDARDS CONSTRUCTION. LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE CONSTRUCTION AND AS A RESULT, CRACKING WILL TYPICALLY OCCUR. THESE FOOT. EXPOSURE C, GCpi=+/-0.55, Ke = 0.99, G = 0.85, Kzt = 1.0 ACI301-10 “SPECIFICATION FOR STRUCTURAL CONCRETE” CRACKS TO NOT TYPICALLY IMPAIR THE INTEGRITY OF THE STRUCTURE. IBC CHAPTER 19 “CONCRETE” HOWEVER, VIRTUS RECOMMENDS A ONE-TIME CRACK REPAIR AND CONTRACTOR OPTIONS COMPONENT AND CLADDING PRESSURES: ACI318-19 “BUILDING CODE REQUIREMENT FOR STRUCTURAL CONCRETE” MAINTENANCE PROGRAM BE IMPLEMENTED FOR THOSE SLABS EXPOSED TO OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS CHOSEN, THE ACI117-10 “SPECIFICATIONS FOR TOLERANCE FOR CONCRETE CONSTRUCTION WATER OR CHEMICALS. THE MAINTENANCE PROGRAM SHALL CONSIST OF: CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES AND AND MATERIALS” · INSPECT SLABS AND SUPPORTING MEMBERS TWO YEARS AFTER SHALL COORDINATE ALL DETAILS WITH ALL TRADES. CONSTRUCTION MIX DESIGN: · DETERMINE CRACKS IN THE STRUCTURE TO BE REPAIRED NOTE PRIORITIES · REPAIR CRACKS NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. FOR THE TOTAL LENGTH OF CRACKING CAN BE ESTIMATE AT 0.009 FEET OF CRACKS BIDDING PURPOSES, WHERE ANY MEMBER IS SHOWN BUT NOT CALLED OUT, THE PER SQUARE FEET OF SLAB AREA. THE OWNER SHOULD RESERVE FUNDS FOR LARGEST SIMILAR MEMBER SHALL BE UTILIZED. THIS ONE TIME MAINTENANCE PROGRAM, WHICH IS TO TAKE PLACE TWO YEARS AFTER THE COMPLETION OF CONSTRUCTION. DIMENSIONS THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL EVEN THOUGH CRACKING IS NORMAL AND MOST OFTEN NOT STRUCTURAL DIMENSIONS WITH ARCHITECTURAL OR HOME DESIGNER DRAWINGS PRIOR TO SIGNIFICANT, WHEN CRACKING OCCURS DURING CONSTRUCTION THE START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ARCHITECT CONTRACTOR SHALL CONTAC THE ARCHITECT/ENGINEER FOR REVIEW. THE OR ENGINEER OF RECORD. DO NOT USE SCALED DIMENSIONS. CONTRACTOR SHOULD BUDGET 0.004 FT OF EPOXY INJECTED CRACK REPAIR PER 309 S DUNHAM AVE SQUARE FOOT OF SLAB. ARLINGTON, WA 98223 DETAIL CALLOUTS ALL DETAILS SHALL BE INCORPORATED INTO THE PROJECT AT ALL STRENGTH TESTING AND ACCEPTANCE APPROPRIATE LOCATIONS, WHETHER SPECIFICALLY CUT OR NOT. TYPICAL NOTES ON MIX DESIGN TABLE TESTING: OBTAIN SAMPLES AND CONDUCT TESTS IN ACCORDANCE WITH ACI301 DETAILS MAY NOT NECESSARILY BE CUT ON PLANS, BUT APPLY UNLESS NOTED 1. CONFORM TO ACI 301 SECTION 4, AND 4.2.1. SECTION 1.6.3.2. ADDITIONAL SAMPLES MAY BE REQUIRED TO OBTAIN OTHERWISE. FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING 2. W/C RATIO SHALL BE BASED ON THE TOTAL WEIGHT OF CEMENTITIOUS CONCRETE STRENGTHS AT ALTERNATE INTERVALS THAN SHOWN BELOW: CONDITION. MATERIALS. MAXIMUM RATIOS ARE CONTROLLED BY STRENGTH NOTED IN TH ETABLE ABOVE, AND DURABILITY REQUIREMENTS IN ACI318 SECTION 19.3. DRAWING DISCREPANCIES CURE (4) CYLINDERS FOR 28-DAY TEST AGE. TEST (1) CYLINDER AT 7 DAYS, TEST 3. CEMENTITIOUS MATERIALS: WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL 2 CYLINDERS AT 28 DAYS AND HOLD 1 CYLINDER IN RESERVE FOR USE AS THE STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS a. THE USE OF FLY ASH, OTHER POZZOLANS, SILICA FUME, OR SLAG SHALL ENGINEER DIRECTS. AFTER 56 DAYS UNLESS NOTIFIED BY THE ENGINEER TO THE SHALL GOVERN. CONFORM TO ACI318 SECTIONS 1903.2 AND 26.4.2.2. MAXIMUM AMOUNT CONTRARY, THE RESERVE CYLINDER MAY BE DISCARDED WITHOUT BEING SMITH REMODEL OF FLY ASH SHALL BE 25% OF TOTAL CEMENTITIOUS CONTENT UNLESS TESTED FOR SPECIMENS MEETING 28-DAY STRENGTH REQUIREMENTS. REVIEWED AND APPROVED OTHERWISE BY STRUCTURAL ENGINEER OF SPECIALTY ENGINEERING RECORD. ANY ENGINEERING DESIGN, PROVIDED BY OTHERS AND SUBMITTED FOR THE NUMBER OF CYLINDERS INDICATED ABOVE REFERENCE 6 BY 12 INCH b.CEMENTITIOUS MATERIALS SHALL CONFORM TO THE RELEVANT ASTM REVIEW, SHALL BEAR THE SEAL OF AN ENGINEER REGISTERED IN THE STATE OF CYLINDER. IF 4 BY 8 CYLINDERS ARE TO BE USED, ADDITIONAL CYLINDERS STANDARDS LISTED IN ACI318 SECTION 26.4.1.1.1 (a). WASHINGTON. THIS IS TO INCLUDE, BUT NOT BE LIMITED TO BRACING AND 7.SEISMIC DESIGN CATEGORY D, SOILS SITE CLASS D, RISK CATEGORY II, Ie=1.0, MUST BE CURED FOR TESTING OF 3 CYLINDERS AT TEST AGE PER THE TABLE OF SHORING WHETHER TEMPORARY OR PERMANENT. 4. AIR CONTENT TO CONFORM TO ACI318 SECTION 19.3.3.1. MINIMUM MIX DESIGN REQUIREMENTS. Ss=1.034g, S1=0.369g, SDs=0.749g STANDARDS FOR EXPOSURE CLASS ARE NOTED IN THE TABLE ABOVE. IF OTHER DRAWINGS FREEZING AND THAWING CLASS IS NOT NOTED, AIR CONTENT GIEN IS THAT ACCEPTANCE: STRENGTH IS SATISFACTORY WHEN THE FOLLOWING CONDITIONS REFER TO THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, CIVIL AND REQUIRED BY THE STRUCTURAL ENGINEER OR RECORD. TOLERANCE IS +/- 1 ARE MET: PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION INCLUDING BUT NOT SOILS AND FOUNDATIONS 1/2%. AIR CONTENT SHALL BE MEASURED AT POINT OF PLACEMENT. · THE AVERAGE OF ALL SETS OF 3 CONSECUTIVE TESTS EQUAL OR EXCEED LIMITED TO: DIMENSIONS, ELEVATIONS, SLOPES, DOOR AND WINDOW OPENINGS, 5. AGGREGATES SHALL CONFORM TO ASTM C33 THE SPECIFIED STRENGTH. NON-BEARING WALLS, STAIRS, FINISHES, DRAINS, WATERPROOFING, RAILINGS, 6.SLUMP: CONFORM TO ACI 301 SECTION 4.2.2.2. SLUMP SHALL BE DETERMINED CURBS DEPRESSIONS, MECHANICAL UNIT LOCATIONS, AND OTHER SOILS REPORT · NO INDIVIDUAL TEST FALLS BELOW THE SPECIFIED STRENGTH BY MORE AT POINT OF PLACEMENT. NO SOILS REPORT WAS PROVIDED FOR THIS PROJECT. CONFORM TO IBC THAN 500 PSI. NONSTRUCTURAL ITEMS. 7. CHLORIDE CONTENT: CONFORM TO ACI318 TABLE 19.3.2.1 CHAPTER 18. THE FOLLOWING DESIGN SOIL VALUES HAVE BEEN ASSUMED IN DESIGN OF THESE DOCUMENTS. SPREAD FOOTINGS SHALL BEAR ON COMPETENT 8. EXPOSURE CLASS IS ASSUMED TO BE F0, S0, W0, AND C0 UNLESS DIFFERENT COORDINATION EXPOSURE IS INDICATED IN THE ABOVE TABLE. CONCRETE PLACEMENT TOLERANCE PERMIT 01/16/2025 NATIVE SOIL OR COMPACTED FILL MATERIAL. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING DETAILS AND CONFORM TO ACI117-10 FOR CONCRETE PLACEMENT TOLERANCE. ACCURACY OF THE WORK; FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR DESIGN SOIL VALUES FLY ASH TECHNIQUES OF ASSEMBLY, AND FOR PERFORMING WORK IN A SAFE AND ALLOWABLE FOUNDATION BEARING PRESSURE 1500 PSF (TOTAL LOAD) NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK OR ARCHITECTURALLY SECURE MANNER. ACTIVE LATERAL PRESSURE 45 PSF/FT EXPOSED CONCRETE. FLY ASH (IF PERMITTED BY ARCHITECTURAL REINFORCING STEEL SPECIFICATIONS) SHALL CONFORM TO ASTM C618, CLASS F AND SHALL BE STANDARDS AT REST RESISTING PRESSURE 250 PSF/FT MEANS METHODS AND SAFETY REQUIREMENTS LIMITED TO 18% OF CEMENTITIOUS MATERIALS AND SHALL HAVE A COEFFICIENT OF FRICTION 0.3 ACI 301-10 “STANDARD SPECIFICATION FOR STRUCTURAL CONCRETE.” THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. CONCRETE SECTION 3 “REINFORCEMENT AND REINFORCEMENT SUPPORTS” CONSTRUCTION AND ALL JOB RELATED SAFETY STANDARDS SUCH AS OSHA. FACTOR OF SAFETY 1.5 SHALL BE FREE OF CHLORIDE. MAXIMUM SLUMP 4 1/2" FOR CONCRETE WITHOUT ACI SP-66(04) “ACI DETAILING MANUAL” THE CONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS OF *IT IS ASSUMED THAT ALL WORK IS PERFORMED ABOVE THE GROUND WATER PLASTICIZER. IF PLASTICIZER IS USED, AN 8" MAXIMUM SLUMP IS ALLOWED AT TH CONSTRUCTION RELATED TO THE INTERMEDIATE STRUCTURAL CONDITIONS. TABLE. PLACEMENT. ALL MIX DESIGNS SHALL BE DESIGNED BY THE CONCRETE CRSE MSP-09 28 EDITION “MANUAL OF STANDARD PRACTICE” PRODUCTION FACILITY IN ACCORDANCE WITH ACI 301 AND SHALL BE REVIEWED IBC CHAPTER 19 “CONCRETE” ALTERNATES FROST DEPTH BY THE STRUCTURAL ENGINEER PRIOR TO PLACEMENT. MIX DESIGNS FOR ACI 318-14 “BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE” ALTERNATE PRODUCTS OF SIMILAR STRENGTH, NATURE, AND FORM FOR FOOTINGS SHALL, AT A MINIMUM, EXTEND BELOW THE ESTABLISHED FROST POST-TENSIONING CONCRETE SHALL BE PROPORTIONED SO AS TO MINIMIZE ACI 117-10 “SPECIFICATIONS FOR TOLERANCES FOR CONCRETE SPECIFIED ITEMS MAY BE SUBMITTED WITH ADEQUATE TECHNICAL DEPTH OF 24”. INTERIOR FOOTINGS, FOOTINGS THAT DO NOT SUPPORT A WALL SHRINKAGE CRACKING. CONSTRUCTION AND MATERIALS” DOCUMENTATION TO THE ARCHITECT/ENGINEER FOR REVIEW. ALTERNATE EXPOSED TO THE EXTERIOR, OR WITHIN 3 FEET OF SUCH A WALL, NEED ONLY MATERIALS THAT ARE SUBMITTED WITHOUT ADEQUATE TECHNICAL EXTEND 12” BELOW THE FINISHED GRADE. VIBRATION DOCUMENTATION OR THAT SIGNIFICANTLY DEVIATE FROM THE DESIGN INTENT MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS OF MATERIALS SPECIFIED MAY BE RETURNED WITHOUT A REVIEW. MATERIALS ON GRADE NEED BE VIBRATED ONLY AROUND UNDER-FLOOR DUCTS, ETC. DO ALTERNATES THAT REQUIRE SUBSTANTIAL EFFORT TO REVIEW WILL NOT BE REINFORCING BARS ASTM A615 GRADE 60 DEFORMED BARS NOT DROP CONCRETE MORE THAN FIVE FEET WITH OUT THE USE OF TREMIES. REVIEWED UNLESS AUTHORIZED BY THE OWNER. REVIBRATE TOPS OF CAISSONS 15 MINUTES AFTER PLACING CONCRETE. BAR SUPPORTS CRSI MSP-09 CHAPTER 3 (BAR SUPPORTS) 24081-0106 TIE WIRE 16 GAGE OR HEAVIER, BLACK ANNEALED CONTROL JOINTS HEADED DEFORMED BARS ASTM A970 S-1.0 01/16/2025 UNLESS APPROVED OTHERWISE IN WRITING BY THE ARCHITECT, ALL CONCRETE GENERAL SLABS ON GRADE SHALL BE BOUND BY CONTROL JOINTS (KEYED OR SAW CUT). NOTES NTS KEYED CONTROL JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING POURING, ALL OTHER JOINTS MAY BE SAW CUT. PLACEMENT STRUCTURAL STEEL PROTECTIVE COATING REQUIREMENTS SHEATHING ACCURATELY PLACE OR SUPPORT ALL REINFORCING, INCLUDING WELDED WIRE SHOP PAINTING SHALL CONFORM TO AISC 360 SECTION M3 AND AISC 303 SECTION WOOD APA-RATED STRUCTURAL SHEATHING INCLUDES ALL VENEER PLYWOOD, STANDARDS FABRIC, WITH GALVANIZED METAL CHAIRS. CONFORM TO ACI 301 SECTION 3.3.2. 6.5 UNLESS OTHERWISE SPECIFIED BY THE PROJECT SPECIFICATIONS. WAFER-BOARD, PARTICLEBOARD, T1-11 SIDING, AND COMPOSITES OF VENEER IBC CHAPTER 22 “STEEL” SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. AND WOOD BASED MATERIAL WITH TONGUE AND GROOVE JOINT. PER ANSI/AISC 303-10 “CODE OF STANDARD PRACTICE FOR STEEL BUILDING AND INTERIOR STEEL NEED NOT BE PAINTED IF THE STEEL SURFACES MEET ANY OF ARCHITECTURAL AND OWNER DIRECTION, NO OSB IS TO BE USED ON THIS FABRICATION BRIDGES” THE FOLLOWING CONDITIONS: PROJECT. CONFIRM WITH ARCHITECT. CONFORM TO “CONSTRUCTION AND TH AISC “MANUAL OF STEEL CONSTRUCTION, 14 EDITION” INDUSTRIAL PLYWOOD” BASED ON PRODUCT STANDARD PS 1-09 BY THE US CONFORM TO ACI 301 SECTION 3.2.2, AND ACI SP-66. · CONCEALED BY THE INTERIOR BUILDING FINISHES AWS D1.1 “STRUCTURAL WELDING CODE - STEEL” DEPARTMENT OF COMMERCE AND “PERFORMANCE STANDARD FOR WOOD · FIREPROOFED 2009 RCSC “SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH STRENGTH BASED STRUCTURAL USE PANELS” BASED ON PRODUCT STANDARD PS 2-10 BY CONCRETE COVER BOLTS” · EMBEDDED IN CONCRETE THE US DEPARTMENT OF COMMERCE AND “PLYWOOD DESIGN SPECIFICATION” CONFORM TO THE FOLLOWING COVE REQUIREMENTS UNLESS NOTED · WELDED; IF AREA REQUIRES PAINTING, DO NOT PAINT UNTIL AFTER WELD BASED ON APA D510C-12 BY THE AMERICAN PLYWOOD ASSOCIATION. UNLESS OTHERWISE IN THE DRAWINGS: INSPECTIONS AND NON-DESTRUCTIVE TESTING REQUIREMENT, IF ANY, ARE NOTED OTHERWISE, SHEATHING SHALL COMPLY WITH THE FOLLOWING TABLE: MATERIALS CONCRETE CAST AGAINST EARTH 3” SATISFIED. WIDE FLANGE (W) SHAPES ASTM A992 Fy=50 KSI CONCRETE PERMANENTLY EXPOSED TO EARTH OR WEATHER 2” · INTERIOR STEEL, EXPOSED TO VIEW, SHALL BE PAINTED WITH ONE COAT OF TIES IN PLINTHS 1 1/2” ANGLE (L) SHAPES ASTM A36 Fy=36 KSI SHOP PRIMER UNLESS OTHERWISE INDICATED IN THE PROJECT STRUCTURAL PLATE (PL) ASTM A36 Fy=36 KSI SPECIFICATIONS. FIELD TOUCH-UPS TO MATCH THE FINISH COAT OR AS BARS EXPOSED TO INTERIOR CONDITIONS ONLY 1” HOLLOW STRUCTURAL SECTION (HSS) AST A500 GRADE B Fy=46 KSI OTHERWISE INDICATED IN THE PROJECT SPECIFICATIONS. HIGH STRENGTH BOLTS ASTM A325/F1852, TYPE 1 OR 3 SPLICES HEAVY HEX NUTS ASTM A563 PER RCSC TABLE 2.1 EXPOSED EXTERIOR STEEL SHALL BE PROTECTED BY ONE OF TWO WAYS. PAINT CONFORM TO ACI 301 SECTION 3.3.2.7. REFER TO TYPICAL LAP SPLICE AND WASHERS ASTM F436 PER RCSC TABLE 2.1 WITH AN EXTERIOR MULTI-COAT SYSTEM AS PER THE PROJECT SPECIFICATIONS, DEVELOPMENT LENGTH SCHEDULE FOR TYPICAL REINFORCEMENT SPLICES. OR BY GALVANIZING. ALL STEEL ELEMENTS NO PROTECTED WITH A PAINT SPLICED INDICATED ON INDIVIDUAL SHEETS SHALL CONTROL OVER THE ANCHOR RODS/BOLTS ASTM 1554 GR. 36 TIMBER CONNECTORS SYSTEM SHALL BE HOT-DIPPED GALVANIZED. SCHEDULE. MECHANICAL CONNECTIONS MAY BE USED WHEN APPROVED BY WELDED HEADED STUD ASTM A108-NELSON/TRW H4L TIMBER CONNECTORS SHALL BE BY THE SIMPSON STRONG TIE COMPANY AS THE ENGINEER OR RECORD. IF TWO BARS OF UNEQUAL DIAMETER ARE SPLICED, SPECIFIED IN THEIR LATEST CATALOG. ALTERNATE CONNECTORS BY OTHER THE SPLICE LENGTH OF THE LARGER BAR SHALL CONTROL. JOINTS USING HIGH STRENGTH BOLTS WOOD FRAMING MANUFACTURES MAY BE SUBSTITUTED PROVIDED THAT THEY HAVE CURRENT · USE ASTM A325-N BOLTS. THREADS NOT EXCLUDED IN THE SHEAR PLANE. IBC CHAPTER 23 “WOOD” ICC APPROVAL FOR EQUIVALENT OR GREATER LOAD CAPACITIES AND ARE FIELD BENDING · HIGH STRENGTH BOLTED JOINTS HAVE BEEN DESIGNED AS BEARING NDS 2016 “NATIONAL DESIGN SPECIFICATION (NDS) FOR WOOD REVIEWED AND APPROVED BY THE ENGINEER OF RECORD PRIOR TO ORDERING. CONFORM TO ACI 301 SECTION 3.3.2.8. BAR SIZES #3 THROUGH #5 MAY BE FIELD CONNECTIONS. CONSTRUCTION” BENT COLD THE FIRST TIME. SUBSEQUENT BENDS AND OTHER BAR SIZES · PROVIDE ASTM BOLT GRADE AND TYPE AS SPECIFIED IN THE “MATERIALS” ANSI/AF&PA SDPWA-15 SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC CONNECTORS SHALL BE INSTALLED PER THE MANUFACTURERS INSTRUCTIONS. REQUIRE PREHEATING. DO NOT TWIST BARS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE LIST ABOVE. APA D510C-12 PLYWOOD DESIGN SPECIFICATION NAILS OR BOLTS IN EACH MEMBER. WHERE STRAPS ARE USED AS HOLD-DOWNS, · PROVIDE WASHERS OVER OUTER PLY OF SLOTTED HOLES AND OVERSIZE ANSI/TPI 1-2014 “NATIONAL DESIGN STANDARD FOR METAL PLATE NAIL STRAPS TO WOOD FRAMING JUST PRIOR TO DRYWALL APPLICATIONS, AS POST-INSTALLED ANCHORS HOLES PER RCSC TABLE 6.1 CONNECTED WOOD TRUS CONSTRUCTION” LATE AS POSSIBLE IN THE FRAMING PROCESS TO ALLOW THE WOOD TO SHRINK STANDARDS · PROVIDE NUT AND WASHER GRADES, TYPES AND FINISHES CONFORMING TO BCI “GUIDE TO GOOD PRACTICE FOR HANDLING, INSTALLING AND BRACING AND THE BUILDING TO SETTLE. PREMATURE NAILING OF THE STRAP MAY LEAD IBC CHAPTER 19 “CONCRETE” TCSC SPECIFICATION TABLE 2.1 OF METAL PLATED CONNECTED WOOD TRUSSES” TO STRAP BUCKLING AND POTENTIAL FINISH DAMAGE. · PROVIDE FASTENER ASSEMBLIES FROM A SINGLE SUPPLIER TPI DSB “RECOMMENDED DESIGN SPECIFICATION FOR TEMPORARY BRACING ACI 318-14 “BUILDING CODE REQUIREMENT FOR STRUCTURAL CONCRETE” · JOINTS SHALL BE “ST” OR SNUG TIGHT. THIS IS FOR TYPICAL BEAM END OF METAL PLATE CONNECTED WOOD TRUSSES” WHERE CONNECTORS ARE IN EXPOSED EXTERIOR APPLICATIONS IN CONTACT POST-INSTALLED ANCHORS (SHEAR TAB) CONNECTIONS, UNLESS NOTED OTHERWISE. APA REPORT TT-045B “MINIMUM NAIL PENETRATION FOR WOOD WITH THE PRESERVATIVE TREATED WOOD (PT) OTHER THAN CCA, CONNECTORS · INSTALL BOLTS IN JOINTS IN ACCORDANCE WITH THE RCSC SPECIFICATION STRUCTURAL PANEL CONNECTIONS SUBJECT TO LATER LOADS” SHALL BE EITHER BATCH HOT-DIPPED GALVANIZED (HDG), MECHANICALLY INSTALL ONLY WHERE SPECIFICALLY SHOWN IN THE DETAILS OR ALLOWED BY SECTION 8 TABLE 4.1 GALVANIZED (ASTM B695 CLASS 55 MINIMUM) STAINLESS STEEL, OR PROVIDED THE ENGINEER OF RECORD. ALL POST INSTALLED ANCHORS TYPES AND · INSPECTIONS PER RCSC SECTION 9. DEFERRED SUBMITTALS WITH 1.85 OX/SF OF ZINC GALVANIZING EQUAL TO OR BETTER THAN SIMPSON LOCATIONS SHALL BE APPROVED BY THE ENGINEER OR RECORD AND SHALL HAVE A CURRENT ICC-EVALUATION SERVICE REPORT THAT PROVIDES SUBMIT PRODUCT DATA AND PROOF OF ICC APPROVAL FOR FRAMING MEMBERS ZMAX FINISH. RELEVANT DESIGN VALUES NECESSARY TO VALIDATE THE AVAILABLE ANCHORAGE TO CONCRETE AND FASTENERS THAT HAVE BEEN DESIGNED BY OTHERS. SUBMIT STRENGTH EXCEEDS THE REQUIRED STRENGTH. ALL STEEL COLUMNS SHALL BE PROVIDED WITH A MINIMUM OF FOUR ¾” CALCULATIONS PREPARED BY THE SPECIALTY STRUCTURAL ENGINEER IN THE NAIL STRAPS TO WOOD FRAMING AS LATE AS POSSIBLE IN THE FRAMING DIAMETER ANCHOR RODS. COLUMN BASE PLATES SHALL BE AT LEAST ¾” THICK, STATE OF IDAHO FOR ALL MEMBERS AND CONNECTIONS DESIGNED BY OTHERS PROCESS TO ALLOW THE WOOD TO SHRINK AND THE BUILDING TO SETTLE. SUBMIT CURRENT MANUFACTURERS DATA AND ICC ESR REPORT TO ENGINEER UNLESS NOTED OTHERWISE. CAST-IN-PACE ANCHOR RODS SHALL BE PROVIDED ALONG WITH SHOP DRAWINGS. ALL NECESSARY BRIDGING, BLOCKING, PREMATURE NAILING OF THE STRAP MAY LEAD TO STRAP BUCKLING AND OF RECORD FOR APPROVAL REGARDLESS OF WHETHER OR NOT IT IS A UNLESS OTHERWISE APPROVED BY THE ENGINEER OR RECORD. UNLESS NOTED BLOCKING PANELS AND WEB STIFFENERS SHALL BE DETAILED AND FURNISHED POTENTIAL FINISH DAMAGE. PRE-APPROVED ANCHOR. ANCHORS SHALL BE INSTALLED IN STRICT OTHERWISE, EMBEDMENT OF CAST-IN-PLACE ANCHOR RODS SHALL BE 12 TIMES BY THE SUPPLIER. TEMPORARY AND PERMANENT BRIDGING SHALL BE THE ANCHOR DIAMETER. INSTALLED IN CONFORMANCE WITH THE MANUFACTURERS SPECIFICATIONS. FASTENERS ACCORDANCE TO ICC-ESR AND THE MANUFACTURERS PRINTED INSTALLATION DEFLECTION LIMITS SHALL BE AS NOTED UNDER DEFERRED SUBMITTALS INSTRUCTIONS IN CONJUNCTION WITH EDGE DISTANCE, SPACING, AND FASTENERS ARE TO INCLUDE NAILS, BOLTS, SCREWS, AND ALL OTHER SIMILAR 309 S DUNHAM AVE SECTION SPECIFIC DETAILS. PRODUCTS TO INCLUDE ARE: SOLID WE WOOD EMBEDMENT DEPTH AS INDICATED ON THE DRAWINGS. FABRICATION JOISTS. MEMBERS. ATTACHING TIMBER CONNECTORS (E.G. HANGARS) TO PT WOOD ARLINGTON, WA 98223 CONFORM TO AISC 360 SECTION M2. THE FOLLOWING QUALITY CONTROL (QC) SHALL HAVE SIMILAR CORROSION RESISTANCE PROPERTIES AS THE PROTECTED THE CONTRACTOR SHALL ARRANGE FOR A MANUFACTURERS FIELD STANDARDS SHALL BE CONFORMED TO: CONNECTOR. FASTENERS ATTACHING SAWN TIMBER MEMERS OR SHEATHING IDENTIFICATION REPRESENTATIVE TO PROVIDE INSTALLATION TRAINING FOR ALL PRODUCTS TO · AISSC 360 CHAPTER N “QUALITY CONTROL AND QUALITY ASSURANCE” TO PT WOOD SHALL BE CORROSION RESISTANT. VERIFY THE SUITABILITY OF BE USED, PRIOR TO THE COMMENCEMENT OF WORK. ONLY TRAINED INSTALLED ALL SAWN LUMBER AND PRE-MANUFACTURED WOOD PRODUCTS SHALL BE THE FASTENER PROTECTION/COATING WITH THE WOOD TREATMENT CHEMICAL · AISE 303 SECTION 8 “QUALITY CONTROL” SHALL PERFORM POST INSTALLED ANCHOR INSTALLATION. A RECORD OF IDENTIFIED BY THE GRADE MARK OR CERTIFICATE OF INSPECTION ISSUED BY MANUFACTURER/SUPLIER. · FABRICATOR AND ERECTOR SHALL ESTABLISH AND MAINTAIN WRITTEN QC THE CERTIFYING AGENCY. TRAINING SHALL BE KEPT ON SITE AND BE MADE AVAILABLE TO THE ENGINEER PROCEDURES PER AISC 360 SECTION N3 OF RECORD AS REQUESTED. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG · FABRICATOR SHALL PERFORM SELF-INSPECTIONS PER AISC 360 SECTION N5 SAWN LUMBER SCREWS BEARING ON WOOD. BOLTS AND LAG BOLTS ARE TO CONFORM TO TO ENSURE THAT THEIR WORK IS PERFORMED IN ACCORDANCE WITH CODE ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY INCLINED OF STANDARD PRACTICE, THE AISC SPECIFICATION, CONTRACT DOCUMENTS SAWN LUMBER SHALL CONFORM TO GRADING RULES OF WWPA, WCLIB, OR ASTM A307 AND IBC SECTION 2304.10. NAILS AND STAPLES SHALL CONFORM TO ORIENTATION SHALL BE PERFORMED BY A CERTIFIED ADHESIVE ANCHOR AND THE APPLICABLE BUILDING CODE. NLGA AND THE TABLE BELOW. FINGER JOINTED STUDS ACCEPTABLE AT ASTM F1667 AND IBC SECTION 2303.6 AND 2304.10. INSTALLER AS CERTIFIED THROUGH ACI/CRSI OR APPROVED EQUIVALENT. INTERIOR WALLS ONLY. SMITH REMODEL · QC INSPECTION MAY BE COORDINATED WITH QUALITY ASSURANCE PROOF OF CURRENT CERTIFICATION SHALL BE SUBMITTED TO THE ENGINEER INSPECTIONS PER SECTION N5.3 WHERE FABRICATORS QA PROCEDURES ENGINEERED WOOD PRODUCTS FOR APPROVAL PRIOR TO COMMENCEMENT OF INSTALLATION. PROVIDE THE NECESSARY BASIS FOR MATERIAL CONTROL, INSPECTION, AND THE FOLLOWING MATERIALS ARE BASED ON LUMBER MANUFACTURED BY CONTROL OF THE WORKMANSHIP EXPECTED BY THE SPECIAL INSPECTOR. TRUSJOIST AND WERE USED FOR THE DESIGN AS SHOWN ON THE PLANS. NO REINFORCING BARS SHALL BE DAMAGED DURING INSTALLATION OF ALTERNATE PRODUCT BY OTHER MANUFACTURERS MAY BE SUBSTITUTED POST-INSTALLED ANCHORS. ANCHOR TYPE, DIAMETER AND EMBEDMENT SHALL WELDING PROVIDED THEY HAVE CURRENT ICC APPROVAL FOR EQUIVALENT OR GREATER BE AS INDICATED ON DRAWINGS. LOAD AND STIFFNESS PROPERTIES AND ARE REVIEWED AND APPROVED BY THE THE FOLLOWING WELDING STANDARDS SHALL BE CONFORMED TO: ENGINEER OF RECORD PRIOR TO ORDERING. · WELDING SHALL CONFORM TO AWS D1.1 WITH PREQUALIFIED WELDING ADHESIVE ANCHORS PROCESSES EXCEPT AS MODIFIED BY AISC 360 SECTION J2. WELDERS SHALL THE LISTED ADHESIVE-TYPE ANCHORING SYSTEMS HAVE BEEN USED IN THE BE QUALIFIED IN ACCORDANCE WITH AWS D1.1 REQUIREMENTS. DESIGN AND SHALL BE USED FOR ANCHORAGE TO CONCRETE, AS APPLICABLE · USE 70KSI STRENGTH, LOW-HYDROGEN TYPE ELECTRODES (E7018) OR E71T AND IN ACCORDANCE WITH CORRESPONDING CURRENT ICC ESR REPORT. AS APPROPRIATE FOR THE PROCESS SELECTED. REFERENCE THE CORRESPONDING ICC ESR REPORT FOR REQUIRED MINIMUM · WELDING OF HIGH STRENGTH ANCHOR RODS IS PROHIBITED UNLESS AGE OF CONCRETE, CONCRETE TEMPERATURE RANGE, MOISTURE CONDITION, APPROVED BY ENGINEER. LIGHT WEIGHT CONCRETE, AND HOLE DRILLING AND PREPARATION REQUIREMENTS. DRILLED IN ANCHOR EMBEDMENT LENGTHS SHALL BE AS · WELDING OF HEADED STUD ANCHORS SHALL BE IN ACCORDANCE WITH AWS PERMIT 01/16/2025 D1.1 CHAPTER 7. SHOWN ON DRAWINGS. ADHESIVE ANCHORS ARE TO BE INSTALLED IN CONCRETE AGED A MINIMUM OF 21 DAYS, UNLESS OTHERWISE SPECIFIED IN THE GLULAM ICC ESR REPORT. ERECTION GLUED LAMINATED TIMER SHALL CONFORM TO AITC 117-2010 “STANDARD THE FOLLOWING ERECTION STANDARDS SHALL BE CONFORMED TO: SPECIFICATIONS FOR STRUCTURAL GLUE-LAMINATED TIMBER OF SOFTWOOD EXPANSION ANCHORS · CONFORM TO AISC 360 SECTION M4 “ERECTION” AND AISC 303 SECTION 7 SPECIES, MANUFACTURING AND DEISGN” AND ANSI/AITC A190.1 “STRUCTURAL THE LISTED EXPANSION TYPE ANCHORS ARE PRE-APPROVED FOR ANCHORAGE “ERECTION.” GLUED LAMINATED TIMER.” CAMBER ALL GLUED LAMINATED BEAMS, EXCEPT TO CONCRETE IN ACCORDANCE WITH CORRESPONDING CURRENT ICC ESR · CONFORM TO AISC CHAPTER N “QUALITY CONTROL AND QUALITY CANTILEVERED AND CONTINUOUS BEAMS, TO 3000' RADIUM, UNLESS SHOWN NAILING REQUIREMENTS REPORT. ASSURANCE” AND AISC 303 SECTION 8. THE ERECTOR SHALL MAINTAIN OTHERWISE ON THE PLANS. FABRICATE CANTILEVERED AND CONTINUOUS CONFORM TO IBC SECTION 2304.10 “CONNECTION AND FASTENERS.” UNLESS DETAILED ERECTION QUALITY CONTROL PROCEDURES THAT ENSURE THAT BEAMS FLAT, UNLESS SHOWN OTHERWISE ON PLANS. GLLULAM MEMBERS TO NOTED ON PLANS, NAIL PER TABLE 2304.10.1. NAILING FOR ROOF/FLOOR THE WORK IS PERFORMED IN ACCORDANCE WITH THESE REQUIREMENT AND CONFORM TO THE TABLE BELOW. SCREW ANCHORS DIAPHRAGMS/SHEAR WALLS SHALL BE PER DRAWINGS. NAILS SHALL BE DRIVEN THE CONTRACT DOCUMENTS. THE LISTED SCREW TYPE ANCHORS ARE PRE-APPROVED FOR ANCHORAGE TO FLUSH AND SHALL NOT FRACTURE THE SURFACE OF SHEATHING. ALTERNATE · STEEL WORK SHALL BE CARRIED UP TRUE AND PLUMB WITHIN THE LIMITS CONCRETE IN ACCORDANCE WITH CORRESPONDING CURRENT ICC ESR REPORT. NAILS MAY BE USED BY ARE SUBJECT TO REVIEW AND APPROVAL BY THE DEFINED IN AISC 303 SECTION 7.13 STRUCTURAL ENGINEER. SUBSTITUTION OF STAPLES FOR THE NAILING OF ADHESIVE · HIGH STRENGTH BOLTING SHALL COMPLY WITH THE RCSC REQUIREMENTS RATED SHEATHING IS SUBJECT TO REVIEW BY THE STRUCTURAL ENGINEER INCLUDING RCSC SECTION 7.2 “REQUIRED TESTING” AS APPLICABLE AND PRIOR TO CONSTRUCTION. HILTI HIT-HY 200 ICC ESR 3187 AISC 360 CHAPTER J, SECTION M2.5 AND SECTION N5.6 SIMPSON SET-XT ICC ESR 2508 · WELDING HEADED STUD ANCHORS SHALL BE IN ACCORDANCE WITH AWS UNLESS NOTED OTHERWISE ON PLANS, ALL NAILS ARE COMMON WIRE NAILS D1.1 CHAPTER 7 “STUD WELDING” AND ARE TO HAVE THE MINIMUM DIMENSIONS AS SHOW IN THE TABLE BELOW. EXPANSION · THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AND SAFETY HILTI KWIK BOLT TZ ICC ESR 1917 PROTECTION REQUIRED BY AISC 360 SECTION M4.2 AND AISC 303 SECTION 24081-0106 SIMPSON STRONG-BOLT 2 ICC ESR 3037 7.10 AND 7.11 S-1.1 DEWALT POWER-STUD +SD2 ICC ESR 2502 01/16/2025 GENERAL SCREW NOTES NTS SIMPSON TITEN HD ICC ESR 2713 HILTI KWIK HUZ-EZ ICC ESR 3027 DEWALT SNAKE ICC ESR 2272 LIGHT-FRAME CONSTRUCTION UNLESS NOTED ON THE PLANS, CONSTRUCTION SHALL CONFORM TO IBC SECTION 2308 “CONVENTIONAL LIGHT0FRAME CONSTRUCTION.” NAILERS ON STEEL MEMBERS WOOD 3X NAILERS ARE GENERALY REQUIRED ON ALL HSS COLUMNS AND STEEL BEAMS ABUTTING OR EMBEDDED WITHIN WOOD FRAMING. UNLESS NOTED OTHERWISE, ATTACH WITH 5/8” DIAMETER BOLTS OR WELDED STUDS AT 16” OC. UNLESS ANOTHER OTHERWISE, WOOD NAILERS ON BEAMS SUPPORTING JOIST HANGARS SHALL NOT OVERHAND THE BEAM FLANGE BY MORE THAN ¼” WOOD SHRINKAGE AND EXPANSION WOOD MATERIALS WILL EXPAND OR CONTRACT BASED ON RELATIVE CHANGES IN MOISTURE. THE CONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION RELATED TO MITIGATING AND MANAGING THE EFFECTS OF CHANGES IN MOISTURE. MOISTURE CONTENT WOOD MATERIAL USED FOR THIS PROJECT SHALL HAVE MAXIMUM MOISTURE CONTENT OF 19% EXCEPT FOR THE PRESSURE-TREATED WOOD SILL PLATE. REFER TO TESTING AND INSPECTION FOR THE VERIFICATION OF THESE LIMITS. THE MAXIMUM MOISTURE CONTENT REQUIRED MAY BE LESS THAN 19% WHEN BASED ON A PARTICULAR CLADDING/INSULATION SYSTEM. REFER TO THE ARCHITECTS DRAWINGS, AND PROJECT SPECIFICATIONS, OR WITH CLADDING INSTALLER FOR MAXIMUM RECOMMENDED MOISTURE CONTENT. SHRINKAGE COMPENSATION FOR MEP SYSTEMS MEP SYSTEMS, INCLUDING DUCTWORK, PIPES, AND OTHER ELEMENTS THAT RUN CONTINUOUSLY BETWEEN LEVELS SHALL BE INSTALLED/DESIGNED IN SUCH A MANNER TO ACCOMMODATE SHRINKAGE IN THE WOOD FRAMING. WOOD SHRINKAGE AMOUNTS WILL VARY DEPENDING ON THE CONSTRUCTION PROCESS AND MATERIALS USED. THE ANTICIPATED SHRINKAGE UNDER TYPICAL CONDITIONS IS EXPECTED TO RANGE BETWEEN 1/8” AND ¼” PER FLOOR. PRESERVATIVE TREATMENT WOOD MATERIALS THAT ARE REQUIRED TO BE “TREATED WOOD” IN ACCORDANCE WITH IBC SECTION 2304.12 “PROTECTION AGAINST DECAY AND TERMITE PROTECTION” SHALL CONFORM TO THE APPROPRIATE STANDARDS OF THE AMERICAN WOOD-PRESERVES ASSOCIATION (AWPA) FOR SAWN LUMBER BLUED LAMINATED TIMBER, ROUND POLES, WOOD PILES, AND MARINE PILES. FOLLOW AMERICAN LUMBER STANDARDS COMMITTEE (ALSC) QUALITY ASSURANCE PROCEDURES. PRODUCTS SHALL BEAR THE APPROPRIATE MARK. FASTENERS OR ANCHORS IN TREATED WOOD SHALL BE OF STAINLESS STEEL OR HOT-DIPPED GALVANIZED OR AS PER IBC 2304.10.5 MUD SILL PLATES IN NORMALLY DRY INTERIOR APPLICATIONS MAY BE TREATED WITH SODIUM BORATE (DOT-DISODIUM OCTABORATE TELRAHYDRATE) AS RECENT STUDIES HAVE NOTED LESS CONNECTOR 309 S DUNHAM AVE CORROSION POTENTIAL THAN OTHER AVAILABLE WOOD TREATMENTS OR THE ORIGINAL CCA TREATED SILL PLATES. WOOD TREATED WITH SODIUM BORATE ARLINGTON, WA 98223 SHALL BE PROTECTED DURING SHIPMENT, STORAGE, AND INSTALLATION TO MINIMIZE LEACHING OF THE WATER-SOLUBLE PRESERVATIVE FROM THE LUMBER. SODIUM BORATE PRESSURE TREATED PLATED DO NOT REQUIRE HOT-DIPPED GALVANIZED CONNECTORS. IF USING PRESERVATIVE TREATMENTS OTHER THAN CCA OR SODIUM BORATE, FASTENERS MUST BE HOT DIPPED GALVANIZED OR STAINLESS STEEL. WOOD TREATED WITH ALKALINE COPPY QUATERNARY (ACQ) REQUIRES STEEL COMPONENTS IN CONTACT WITH THE WOOD TO BE STAINLESS. FASTENERS ATTACHING TIMBER CONNECTORS TO PT WOOD SHALL HAVE SIMILAR SMITH REMODEL CORROSION RESISTANCE PROPERTIES AS THE PROTECTED CONNECTOR, THAT IS, USE HOT DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. FASTENERS ATTACHING SAWN TIMBER MEMBERS OR SHEATHING TO PRESSURE TREATED WOOD SHALL BE CORROSION RESISTANT. ALWAYS VERIFY THE SUITABILITY OF THE FASTENER PROTECTION/COATING PERMIT 01/16/2025 24081-0106 S-1.2 01/16/2025 GENERAL NOTES NTS 5" Ø X 24" SMOOTH BAR @ SLAB ON GRADE AND (3) #5 DOWELS. DRILL AND EPOXY 8" MIN 8 INTO FACE OF EXISTING FOOTING. SIMPSON 24" OC. GREASE ONE REINFORCING PER SIDE OF DOWEL PLAN, TYPICAL SET-XP EPOXY OR ACCEPTABLE TOP OF ALTERNATIVE. SLAB NEW STEM WALL, FOOTING, AND REINFORCING PER PLAN 16" MIN 4d 2 1" MIN 2 VAPOR BARRIER WHERE 6" SUBGRADE PREPARATION PER REQUIRED, TYPICAL GEOTECH REPORT, TYPICAL COMPETENT NATIVE SOIL PER 90° 45° CONSTRUCTION JOINT GEOTECH REPORT, TYPICAL R R SAW CUT OR 1 1" WIDE PREMOLDED R 180° 2 12d JOINT. DEPTH OF JOINT TO BE 1 OF THE SLAB THICKNESS 4 R FOOTING INTO PLINTH 45° TOP OF 3" SLAB R = 6d FOR #3 THROUGH #8 R = 8d FOR #9 THROUGH #11 EXISTING BASEMENT STRUCTURAL FILL. WALL 95% COMPACTION. 12" MAX LIFTS, TYP CONTROL JOINT NOTES NOTES d = DIAMETER OF REINFORCING BAR NOTES 1. CONSTRUCTION JOINT IS A JOINT BETWEEN DIFFERENT POURS. CONTROL JOINT IS A CRACK CONTROL JOINT WITHIN THE SAME POUR. R = RADIUS OF BAR BEND 1. ALL VALUES ARE IN INCHES. 2. USE EARLY ENTRY DRY-CUT SAW AS SOON AS POSSIBLE WITHOUT CAUSING RAVELING OF 2. TOP BAR IS ANY HORIZONTAL BAR WITH AT LEAST CONCRETE EDGES. SAWCUT ALONG SHORT DIRECTION OF POUR FIRST. 3. ALIGN A CONSTRUCTION OR CONTROL JOINT WITH RE-ENTRANT SLAB CORNERS EACH WAY. 12" OF MONOLITHIC POURED CONCRETE BELOW 4. PROVIDE JOINTS TO ENCLOSE APPROXIMATE SQUARE AREA (PANEL) OF 225 SQUARE FEET, MAXIMUM. MAXIMUM PANEL ASPECT RATIO OF 1.3. 5. CONTRACTOR TO SUBMIT JOINT PLAN TO STRUCTURAL ENGINEER OF RECORD FOR REVIEW/APPROVAL POST INSTALLED ANCHORS AT TYPICAL SLAB-ON-GRADE JOINT LAP SPLICE AND DEVELOPMENT 1 FOOTING INTERFACE DETAILS BAR BEND DIAGRAM LENGTH SCHEDULE SCALE: NTS 2 SCALE: 3/4" = 1' 3 SCALE: 3/4" = 1' 4 SCALE: NTS CONCRETE WALL PER PLAN DOWEL WITH STANDARD HOOK TO MATCH FOOTING REINFORCING POST PER PLAN Ld PER SCHED POST BASE PER PLAN. SLAB ON GRADE AND ACTUAL MODEL MAY NOT TOP OF REINFORCING PER PLAN BE SHOWN FOOTING CONCRETE PLINTH H ANCHORAGE PER PLAN PER PLAN 3" CLR, TYPICAL 4' MAX BEND DOWELS TO MATCH 309 S DUNHAM AVE H FOOTING REINFORCING TOP OF LAP PER SCHEDULE, 4' MAX SLAB TYPICAL (3) #4 DOWELS FROM ARLINGTON, WA 98223 FOOTING INTO PLINTH 8" MIN TOP OF FINISHED GRADE STEEP AS POSSIBLE, TYPICAL 2 BENT DOWEL TO MATCH FOOTING REINFORCING FTG 1 TURNED DOWN EDGE 1.5H MIN FOOTING REINFORCING THICKNESS PER PLAN FOOTING AND REINFORCING PER PLAN 3" CLEAR AT CORNERS AT INTERSECTIONS NOTE (2) #4 BOTTOM BAR CAST DOWELS TO MATCH VERTICAL WALL REINFORCING. NOT SHOWN PER PLAN FOR CLARITY. NOTE: SMITH REMODEL FOOTING REINFORCING PER PLAN. BOTTOM OF FOOTING BELOW FROST DEPTH PER JURISDICTION TURNED DOWN EDGE AT SLAB-ON- CORNER AND INTERSECTING POST FOOTING AT CONCRETE TYPICAL STEPPED FOOTING GRADE 7 FOOTINGS PLINTH 5 SCALE: 1/2" = 1' 6 SCALE: 1" = 1' SCALE: 3/4" = 1' 8 SCALE: 3/4" = 1' STUD WALL AND SHEATHING PER PLAN BUNDLED STUDS PER PLAN. STUD WALL AND SHEATHING PERMIT 01/16/2025 SECTION 2 STUDS, MIN. PT PLATE AND ANCHOR PIPE SLEEVE AS BOLTS PER PLAN REQUIRED, TYPICAL EXPANSION JOINT AT SLAB PT BOTTOM PLATE STEM WALL PER PLAN ON GRADE, IF APPLICABLE #4 HORIZONTAL BARS @ 18" WITH ANCHOR BOLTS PER 11/S-4.0 OC CENTERED IN WALL SLAB ON GRADE AND 1" CLR, REINFORCING WHERE OCCURS TYPICAL STRAP HOLD DOWN PER PLAN #4 HOOKED VERTICAL BARS @ 18" OC CENTERED IN WALL TOP OF CONCRETE FOOTING PER PLAN FINISHED GRADE TOP OF FOOTING 4" MIN CONCRETE STEMWALL BOT OF TOP OF PER PLAN PER PLAN FOOTING 3'-0' MAX FINISHED GRADE FOOTING DEPTH 4" MIN AT CONTRACTORS OPTION, TURNED DOWN EDGE EXCAVATION FOR TRENCH CONCRETE FOOTING AND 3'-0" MAX 6" MIN NOT ALLOWED BELOW THIS REINFORCEMENT PER PLAN EQ EQ LINE 18" MIN 1 3" CLR PLACE CONCRETE FILL 1 BEFORE FOOTING POUR ALTERNATE HOOK NOTES EVERY OTHER BAR 1. PRIOR TO CONSTRUCTION, STRUCTURAL ENGINEER OF RECORD SECTION SHALL REVIEW PIPES/SLEEVES GREATER THAN 8" DIAMETER NOTE AND/OR SPACED CLOSER THAN 3" APART. AT "SIM" CONDITION, OMIT SLAB ON GRADE, 2. ALUMINUM MATERIALS SHALL NOT BE EMBEDDED IN CONCRETE. AND EPOXY VERTICAL REINFORCING INTO EXISTING STEM WALL TO MATCH 5/S3.0 24081-0106 S-2.0 01/16/2025 TYPICAL EXTERIOR STEM WALL AND FOUNDATION DETAILS TYPICAL PIPE THROUGH FOUNDATION FOOTING AND/OR STEMWALL STRAP HOLD DOWN INSTALLATION FOOTING AS NOTED 9 SCALE: 1/2" = 1' 11 SCALE: NTS 12 SCALE: 3/4" = 1' STRAP AND NAILING PER PLAN EDGE NAILING FULL BUNDLED STUDS OR HEIGHT OF STUD EDGE NAILING PER PLAN POST PER PLAN ADDITIONAL STUD, IF HOLD DOWN PER PLAN REQUIRED PER STRAP STUD OR SHEAR WALL CONTINUES, WHERE OCCURS PER PLAN STUD OR SHEAR WALL CONTINUES, WHERE OCCURS PER PLAN STAGGER 0.131"Øx31" NAILS STAGGER 0.131"Øx31" NAILS 2 2 PER SHEAR WALL SCHEDULE PER SHEAR WALL SCHEDULE EDGE NAILING PER PLAN EDGE NAILING PER PLAN STUD WALL AND SHEATHING STUD WALL AND SHEATHING PER PLAN PER PLAN 3 CORNER AND INTERSECTING SHEAR WALLS SCALE: 1" = 1' ANCHOR BOLT PER 11/S-4.0, TYPICAL ANCHOR BOLT PER 11/S-4.0 PT SILL PLATE PER PLAN, TYIPCAL SHEATHING WHERE OCCURS PER PLAN WALL STUD SPACING HOLD DOWN PER PLAN PER PLAN, TYP TYPICAL BUNDLED STUDS PER PLAN 5" MIN, 12" MAX 5" MIN, 12" MAX NOTCH IN SILL PLATE 8" MAX WALL STUDS PER PLAN NOTES: 1. ADDITIONAL INFORMATION PER 10/S-3.0 2. TREAT NOTCHES IN SILL PLATES AS WALL ENDS. PROVIDE ANCHOR ON BOTH NOTE: SIDES. SINGLE TIMBERS MAY BE USED IN LIEU OF 3. AT SHEAR WALLS, PLATE WASHER PER SHEAR WALL SCHEDULE. STANDARD CUT BUNDLED STUDS, PROVIDED THAT TOTAL WOOD SMITH REMODEL WASHERS AT NON SHEAR WALLS. CROSS SECTION AREA REMAINS THE SAME. 7 SILL PLATE ANCHORAGE - PLAN END OF SHEAR WALLS SCALE: 1" = 1' 8 SCALE: 1" = 1' STUD WALL PER PLAN 5" MIN STUDS PER PLAN 1'-0" MAX 6'-0" MAX PERMIT 01/16/2025 5"Ø ANCHOR BOLT X 6" 8 LONG, TYPICAL WALL END PER PLAN HOLD DOWN PER PLAN PT SILL PLATE ANCHOR ROD PER PLAN TOP OF CONCRETE DRILL AND EPOXY PER PLAN EXISTING CONCRETE WALL CONCRETE STEM WALL PER PLAN NOTES: 1. PROVIDE (2) BOLTS, MINIMUM ON EACH SILL PLATE PIECE. 2. OVERSIZE HOLES ARE NOT PERMITTED. USE 11"Ø 16 DRILL BIT. 3. SILL PLATE THICKNESS PER PLAN. AT SHEAR WALLS, THICKNESS PER SHEAR WALL SCHEDULE. 4. CONTACT ENGINEER OF RECORD FOR POST INSTALLED 24081-0106 ANCHOR OPTIONS. S-3.0 01/16/2025 POST INSTALLED ANCHORS AT WOOD WALL ANCHORAGE FOOTING INTERFACE SILL PLATE ANCHORAGE - SECTION AS NOTED 11 SCALE: NTS 12 SCALE: 1/2" = 1' (2) 2x4 STUDS (3) 2x4 STUDS (3) 2x6 STUDS WALL FRAMING ABOVE, RIM JOIST PER PLAN WHERE OCCURS 1" 21" 11" 31" 11" 1 2 2 2 2 32" FRAMING AT LEVEL ABOVE, BLOCKING, WIDTH TO MATCH WHERE OCCURS HD HOLD DOWN PER PLAN, 8" TYP 8" TYP TRIMMER AND KING STUDS 6" TYP TOP OF WHERE OCCURS SHEATHING ABOVE, WHERE OCCURS RIM JOIST PER PLAN 1" 11" 11" WALL LENGTH PER PLAN 2 2 PLATE NAILING PER PLAN STRAP HOLD DOWN WHERE PONY WALL FRAMING TOP OF SHEATHING OCCURS PER PLAN BOTTOM PLATE SHEATHING PER SHEAR DOUBLE TOP PLATE WALL SCHEDULE DOUBLE TOP PLATE FIELD NAILING PER 2X BLOCKING AT PONY WALL STUDS, TO PLAN, TYP PANEL EDGES MATCH STUDS ABOVE HEADER PER PLAN 1 EDGE NAILING PER TRIMMER STUDS PER (3) 8dx34" NAILS BUNDLED STUDS PER PLAN, TYP PLAN EACH END, TYPICAL PLAN, TYPICAL SILL, IF OPENING HD HOLD DOWN AND STRAP HOLD DOWN, WHERE IS A WINDOW ANCHORAGE PER PLAN OCCURS, PER PLAN (2) 2X4 LAMINATIONS W/ (3) 2X4 LAMINATIONS W/ (1) (3) 2X6 LAMINATIONS W/ (2) (1) ROW OF 10dx31" ROW OF 10dx31" NAILS EACH ROWS OF 10dx31" NAILS EACH 2 2 2 NAILS, STAGGERED LAYER, STAGGERED BETWEEN LAYER, STAGGERED BETWEEN PONY WALL IF OPENING STUD WALL FRAMING LAYERS EACH SIDE LAYERS EACH SIDE IS A WINDOW PER PLAN PT SILL PLATE AND ANCHOR BOLTS PER PLAN CONC STEMWALL & NOTE: FOOTING PER PLAN EACH ADDITIONAL LAMINATION OVER (3) LAMINATIONS SHALL BE NAILED TO THE ASSEMBLY WITH 10dx31" COMMON WIRE NAILS, KING STUD(S) PER PLAN 4 STAGGERED EACH SIDE OF BUNDLED STUDS NAILING FOR BUNDLED STUDS TYPICAL HEADER 4 SHEAR WALL ELEVATION 2 SCALE: 3/4" = 1' 3 SCALE: 1/2" = 1' SCALE: 1/4" = 1' 2 ROWS 10dx31" NAILS, (16) 4 4'-0" MIN SPLICE LAP TOTAL, STAGGERED WITHIN AREA OF SPLICE @ 6" OC PLATE SPLICE TO OCCUR OVER STUDS DOUBLE TOP PLATE A STUD WALL PER PLAN SMITH REMODEL G B C D PLATE SPLICE DETAIL A E 6 F B SCALE: 3/4" = 1' B H MAX NOTCH DEPTH SAW CUT MAX DIAMETER OF D, MIN BETWEEN NOTCH BORED HOLE AND BORED HOLE CIRCULAR NOTCH PERMIT 01/16/2025 J "V" NOTCH MIN DEPTH MIN REMAINING DEPTH LET-IN NOTCH 1. INSTALL PANEL EITHER HORIZONTALLY OR VERTICALLY. 2. BLOCKING REQUIRED ON ALL PANEL EDGES, EXCEPT AT W6 WALLS. D, MIN BETWEEN TWO 3. SHEATHING EDGE NAILING IS REQUIRED AT ALL HOLD DOWN POSTS. EDGE NAILING MAY ALSO BE REQUIRED TO EACH STUD USED IN BUILT-UP HOLD BORED HOLES DOWN POSTS. ADDITIONAL INFORMATION PER HOLD DOWN DETAILS. D, MAX 1 1 4. BASED ON 0.131"Øx1 2" NAILS USED TO ATTACH FRAMING CLIPS DIRECTLY TO FRAMING. USE 0.131"Øx2 2" NAILS WHERE INSTALLED OVER SHEATHING. 5. FRAMING CLIPS: LTP5 MAY BE USED IN LIEU OF A35. STUD WIDTH, D STUD WIDTH, D 6. WHERE BOTTOM PLATE ATTACHMENT SPECIFIES (2) ROWS OF NAILS, PROVIDE DOUBLE JOIST, RIM JOIST, OR EQUAL BELOW. STAGGER NAILS IN ROWS 1 1" APART, MINIMUM. 2 7. ANCHOR BOLTS SHALL BE PROVIDED WITH HOT-DIPPED GALVANIZED STEEL PLATE WASHERS 0.229"x3"x3" MINIMUM. THE HOLE IN THE PLATE WASHER MAY BE DIAGONALLY SLOTTED 13"x1 3" PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND NUT. PLATE WASHER 16 4 TO EXTEND TO WITHIN 1" OF THE EDGE OF TEH SILL PLATE ON THE SIDE WITH SHEATHING. AT 2x6 WALLS WITH SHEATHING ON BOTH SIDES USE 2 PLATE WASHER 0.229"x4 1"x4 1" MINIMUM. EMBED ANCHOR BOLTS 7" MINIMUM INTO THE CONCRETE. 2 2 8. PRESSURE TREATED MATERIAL CAN CAUSE EXCESSIVE CORROSION IN THE FASTENERS. PROVIDE HOT-DIPPED GALVANIZED NAILS AND CONNECTOR PLATES (E.G. CLIPS) FOR ALL CONNECTORS IN CONTACT WITH PRESSURE TREATED FRAMING MEMBERS. ADDITIONAL INFORMATION PER STRUCTURAL GENERAL NOTES. 9. WHERE WOOD SHEATHING IS APPLIED OVER GYPSUM SHEATHING, CONTACT THE ENGINEER OF RECORD FOR ALTERNATIVE NAILING REQUIREMENTS. 10. AT ADJOINING PANEL EDGES (2) 2x STUDS NAILED TOGETHER MAY BE USED IN PLACE OF A SINGLE 3x STUD. DOUBLE 2x STUDS SHALL BE CONNECTED TOGETHER PER DETAIL 1/S-1.1. 11. CONTACT THE STRUCTURAL ENGINEER OF RECORD FOR ADHESIVE OR EXPANSION BOLT ALTERNATIVES TO CAST-IN-PLACE ANCHOR BOLTS. 24081-0106 12. NAIL STUDS TO 3X SILL PLATES WITH EITHER (2) 0.148"Øx4" END NAILS OR (4) 0.131"Øx2 1" TOENAILS. 2 13.EDGE NAILS SHALL BE LOCATED 3" FROM PANEL EDGES. 8 S-3.1 01/16/2025 STANDARD HOLES AND NOTCHES WOOD WALL FRAMING IN STUDS 11 SHEAR WALL SCHEDULE AS NOTED 10 SCALE: 3/4" = 1' SCALE: NTS 1 SHEATHING PER PLAN (2) 8d X 2 2" NAILS FROM JOIST INTO 2x BLOCKING TOP OF SHEATHING JOIST PER PLAN, TYPICAL DIAPHRAGM EDGE NAILING PER PLAN STUD WALL AND ADDITIONAL NAILING & BLOCKING 2x BLOCKING WITH SHEATHING PER PLAN BREAK RIM JOIST AT REQUIRED FOR (2) ROWS OF PLATE 1 BEAM (4) 8d X 2 2" NAILS NAILING PER SHEAR WALL SCHEDULE TOP OF 1" SHEATHING 2 PLATE ATTACHMENT PER DIAPHRAGM EDGE DTC CLIP SHEAR WALL SCHEDULE WEB STIFFENER PER JOIST NAILING PER PLAN BLOCKING @ 48" OC TO MATCH MANUFACTURER. NAIL WITH RIM JOIST PER PLAN JOISTS. MINIMUM OF (2) PER NON BEARING STUD WALL 1 PER ARCH (4) 10d COMMON NAILS X 3 2" DIAPHRAGM EDGE TOP OF WALL SEGMENT NAILING PER PLAN SHEATHING 2x4 W/ (4) 8D X 3 1" NAILS 4 PER PLAN WALL PARALLEL TOP OF BEAM PER PLAN TO JOISTS SHEATHING PER PLAN SHEATHING RIM JOIST PER PLAN TOP OF STUD WALL AND SHEATHING JOIST PER PLAN, TYPICALJOIST PER PLAN, TYPICAL JOIST PER PLAN SHEATHING PER PLAN BLOCKING @ 48" OC W/ (2) 8DX3 1" 4 RIM JOIST CONNECTION PER TOENAILS TO TOP PLATE SHEAR WALL SCHEDULE JOIST PER PLAN LSL BLOCKING TO EXISTING CONCRETE MATCH RIM JOIST WALL PER PLAN DTC CLIP RIM JOIST CONNECTION PER SHEAR WALL SCHEDULE, NON BEARING STUD WALL COLUMN F PER ARCH WALL PERPENDICULAR TO JOISTS NOTES: FLOOR FRAMING AT PARALLEL SIMPSON STRONG TIE SDPW SCREWS MAY BE USED IN LIEU OF DTC JOISTJOISTS EACH SIDE CANTILEVERED BEAM NON BEARING WALL CONNECTIONS FLOOR OVERHANG 1 SCALE: 2 SCALE: 3/4" = 1' 3 SCALE: 3/4" = 1' 4 SCALE: 3/4" = 1' ADDITION SHEAR WALL SHEATHING WHERE APPLICABLE, TYPICAL ADDITION SHEAR WALL SHEATHING WHERE APPLICABLE, TYPICAL PLATE ATTACHMENT PER PLATE ATTACHMENT PER ADDITION SHEAR WALL SHEATHING ADDITIONAL NAILING & BLOCKING SHEAR WALL SCHEDULE SHEAR WALL SCHEDULE WHERE APPLICABLE, TYPICAL REQUIRED FOR (2) ROWS OF PLATE STUD WALL AND PLATE ATTACHMENT PER NAILING PER SHEAR WALL SCHEDULE ADDITIONAL NAILING & BLOCKING ADDITION SHEAR WALL SHEATHING SHEATHING PER PLAN SHEAR WALL SCHEDULE DIAPHRAGM EDGE REQUIRED FOR (2) ROWS OF PLATE DIAPHRAGM EDGE WHERE APPLICABLE, TYPICAL NAILING PER PLAN NAILING PER SHEAR WALL SCHEDULE NAILING PER PLAN ADDITIONAL NAILING & BLOCKING DIAPHRAGM EDGE PLATE ATTACHMENT PER REQUIRED FOR (2) ROWS OF PLATE DIAPHRAGM EDGE NAILING PER PLAN SHEAR WALL SCHEDULE NAILING PER SHEAR WALL SCHEDULE NAILING PER PLAN RIM JOIST PER PLAN RIM JOIST PER PLAN ADDITIONAL NAILING & BLOCKING REQUIRED FOR (2) ROWS OF PLATE TOP OF TOP OF DIAPHRAGM EDGE SHEATHING SHEATHING NAILING PER SHEAR WALL SCHEDULE RIM JOIST PER PLAN 1 NAILING PER PLAN 2x4 W/ (4) 8D X 3 4" NAILS TOP OF RIM JOIST CONNECTION PER SHEATHING SHEAR WALL SCHEDULE WEB STIFFENER WHERE REQD TOP OF SHEATHING BY MANUFACTURER JOIST PER PLAN JOIST PER PLAN W/ (2) 8DX3 1" RIM JOIST CONNECTION PER 4 BLOCKING @ 48" OC W/ (2) 8DX3 1" NAILS TO TOP PLATE SHEAR WALL SCHEDULE 4 TOENAILS TO TOP PLATE JOIST PER PLAN W/ (2) 8DX3 1" RIM JOIST CONNECTION PER NAILS TO TOP PLATE 4 STUD WALL AND STUD WALL AND SHEAR WALL SCHEDULE SHEATHING PER PLAN 1 FULL DEPTH BLOCKING TO SHEATHING PER PLAN JOIST PER PLAN W/ (2) 8DX3 4" NAILS TO TOP PLATE MATCH RIM JOIST STUD WALL AND 2X BLOCKING WITH 2X BLOCKING WITH SHEATHING PER PLAN PLATE ATTACHMENT PER PLATE ATTACHMENT PER RIM JOIST CONNECTION PER WEB STIFFENER WHERE REQD SHEAR WALL SCHEDULE SHEAR WALL SCHEDULE SHEAR WALL SCHEDULE BY MANUFACTURER WEB STIFFENER WHERE REQD BY MANUFACTURER SMITH REMODEL 2X BLOCKING 2X BLOCKING STUD WALL AND SHEATHING PER PLAN FLOOR FRAMING AT CONTINUOUS FLOOR FRAMING PARR/PERP TO FLOOR FRAMING PERPENDICULAR JOIST WALL FLOOR FRAMING PARALLEL TO WALL TO WALL 5 SCALE: 3/4" = 1' 6 SCALE: 3/4" = 1' 7 SCALE: 3/4" = 1' 8 SCALE: 3/4" = 1' ADDITION SHEAR WALL SHEATHING STUD WALL AND ADDITION SHEAR WALL SHEATHING WHERE APPLICABLE, TYPICAL SHEATHING PER PLAN WHERE APPLICABLE, TYPICAL STUD WALL AND PLATE ATTACHMENT PER ADDITION SHEAR WALL SHEATHING STUD WALL AND PERMIT 01/16/2025 ADDITION SHEAR WALL SHEATHING SHEATHING PER PLAN SHEAR WALL SCHEDULE WHERE APPLICABLE, TYPICAL SHEATHING PER PLAN WHERE APPLICABLE, TYPICAL ADDITIONAL NAILING & BLOCKING PLATE ATTACHMENT PER PLATE ATTACHMENT PER ADDITIONAL NAILING & BLOCKING SHEAR WALL SCHEDULE PLATE ATTACHMENT PER REQUIRED FOR (2) ROWS OF PLATE DIAPHRAGM EDGE REQUIRED FOR (2) ROWS OF PLATE SHEAR WALL SCHEDULE SHEAR WALL SCHEDULE ADDITIONAL NAILING & BLOCKING NAILING PER SHEAR WALL SCHEDULE NAILING PER PLAN NAILING PER SHEAR WALL SCHEDULE ADDITIONAL NAILING & BLOCKING REQUIRED FOR (2) ROWS OF PLATE DIAPHRAGM EDGE REQUIRED FOR (2) ROWS OF PLATE NAILING PER SHEAR WALL SCHEDULE DIAPHRAGM EDGE NAILING PER SHEAR WALL SCHEDULE RIM JOIST PER PLAN NAILING PER PLAN NAILING PER PLAN DIAPHRAGM EDGE DIAPHRAGM EDGE TOP OF NAILING PER PLAN SHEATHING NAILING PER PLAN RIM JOIST PER PLAN TOP OF TOP OF TOP OF SHEATHING SHEATHING SHEATHING RIM JOIST PER PLAN 2x4 W/ (4) 8D X 3 1" NAILS 4 RIM JOIST CONNECTION PER SHEAR WALL SCHEDULE WEB STIFFENER WHERE REQD BY MANUFACTURER JOIST PER PLAN W/ (2) 8DX3 1" RIM JOIST CONNECTION PER 4 NAILS TO TOP PLATE SHEAR WALL SCHEDULE JOIST PER PLAN 1 FULL DEPTH BLOCKING TO JOIST PER PLAN W/ (2) 8DX3 1" RIM JOIST CONNECTION PER JOIST PER PLAN W/ (2) 8DX3 4" WEB STIFFENER WHERE REQD 4 NAILS TO TOP PLATE MATCH RIM JOIST BLOCKING @ 48" OC W/ (2) 8DX3 1" NAILS TO TOP PLATE SHEAR WALL SCHEDULE BY MANUFACTURER PT 2X6 PLATE, ATTACHMENT 4 PER SHEAR WALL SCHEDULE TOENAILS TO TOP PLATE WEB STIFFENER WHERE REQD RIM JOIST CONNECTION PER BY MANUFACTURER SHEAR WALL SCHEDULE CONCRETE WALL AND PT 2X6 PLATE, ATTACHMENT PT 2X6 PLATE, ATTACHMENT REINFORCING PER PLAN PER SHEAR WALL SCHEDULE PT 2X6 PLATE, ATTACHMENT PER SHEAR WALL SCHEDULE CONCRETE WALL AND PER SHEAR WALL SCHEDULE CONCRETE WALL AND REINFORCING PER PLAN REINFORCING PER PLAN CONCRETE WALL AND REINFORCING PER PLAN 24081-0106 S-3.2 01/16/2025 GROUND FLOOR FRAMING AT GROUND FLOOR FRAMING GROUND FLOOR FRAMING PARALLEL GROUND FLOOR FRAMING WOOD FLOOR FRAMING AS NOTED CONTINUOUS JOIST PARR/PERP TO WALL TO WALL PERPENDICULAR TO WALL DETAILS 9 SCALE: 3/4" = 1' 10 SCALE: 3/4" = 1' 11 SCALE: 3/4" = 1' 12 SCALE: 3/4" = 1' PT JOIST PER PLAN TOP OF SHEATHING JOIST PER PLAN W/ (2) 8DX3 1" HANGER PER PLAN 4 NAILS TO TOP PLATE LEDGER AND CONNECTION PER PLAN STUD WALL AND SHEATHING PER PLAN TOP OF SHEATHING ROOF FRAMING AT 4 SCALE: 3/4" = 1' BLOCKING AT EACH JOIST SIMPSON HU FACE MOUNT 12 HANGER AT EACH OUTRIGGER PER 5" DIAMETER WELDED 2x4 OUTRIGGER @ 24" OC ARCH 8 COUNTERSINK 1" MAX THREADED STUD @ 16" OC SHEATHING SIMPSON BA OR HB AND 6" FROM EACH END PER PLAN TOP FLANGE HANGER SHEATHING PER PLAN WITH SLOPED SEAT SHEATHING PER PLAN CONTINUOUS 3x NAILER LINE JOIST PER PLATE PLAN TOP OF SHEATHING SIMPSON H1A TIE AT EACH OUTRIGGER RAFTER PER PLAN, TYPICAL BEAM PER PLAN 2'-0" MAX BEAM PER PLAN TRUSS PER PLAN, TYPICAL SMITH REMODEL RIDGE BEAM CONNECTION WOOD NAILER OVER STEEL BEAM ROOF FRAMING PARALLEL TO WALL 6 SCALE: NTS 7 SCALE: 1" = 1' 8 SCALE: EXISTING SHEATHING USS PE 2X BLOCKING STIFFENER PL3" EACH SIDE. WOOD NAILER PER 8 CHAMFER CORNERS TO AVOID K REGION 10/S-4.2 SIMPSON VPA PERMIT 01/16/2025 EXISTING JOIST BEAM PER PLAN CONTINUOUS BEVELED PLATE 1 " 1/4 2 TYP 2'-0" MAX 1/4 2" BEAM PER PLAN HARDWARE OPTION 1 " 2 SHEATHING 1/4 3 PER PLAN WHERE BEAM IS CONTINUOUS CAP PL8" X 6" X 0'-10" 3" MIN CEILING JOISTS OVER THE SUPPORT, EXTEND WITH (2) 3" BOLTS PER PLAN ALL CALLOUTS 4 ROOF RAFTER BEAM PER PLAN, PERP LAN TYP LE TOP PLATE POST PER PLAN 2'-0" MAX BIRDS MOUTH OPTION 24081-0106 CEILING BY OTHERS S-4.2.0 01/16/2025 STEEL POST TO STEEL BEAM ROOF FRAMING PERPENDICULAR TO ROOF AND MISC FRAMING BEAM BRACE BELOW RAFTERS AS NOTED 10 CONNECTION WALL DETAILS SCALE: NTS 11 SCALE: 1" = 1' 12 SCALE: WSU Code Compliance Calculator, WSEC 2021 Project Information Messages / Results * Small dwelling unit example Review of Baseline Required - UA Reduction = 228.9, compared to user-defined baseline UA. Check that this is required % reduction compared to Additio Contact Information Window area is 11% of floor area - Whole House Mechanical Ventilation Airflow Rate: 137.5 CFM with Run Time Percent of 50%, Unbalanced, Distributed * Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ. ANALYSIS SET UP What code compliance pathway are you using? User-Defined Baseline (Addition/Remodel/Alteration of Existing) Project Building Type? Addition Occupancy Type? R3 Single family homes and duplexes Code Version? WSEC 2021 WSEC-R Rev: Oct. 2023, https://www.sbcc.wa.gov/sites/default/files/2023-12/OT Classification: Medium Dwelling Unit -- 2199 sq. ft. Baseline Description: Existing Baseline - Baseline and proposed window areas are equal. About Your Selection: Up to 15 sf exempt window and 24 sf exempt door allowable. Enter baseline design details to right of proposed design below RESULTS - Comparison of Baseline and Proposed Design Component Performance, R occupancies Baseline Proposed Design U * Area UA U Area UA Doors U = 0.474 37 17.4 0.300 100 30.0 Overhead Glazing U = 0.500 16 8.0 0.500 8 4.0 Vertical Glazing U = 0.400 251 100.5 0.300 251 75.4 Flat/Vaulted Ceilings U = 0.049 1,115 54.6 0.029 1,499 42.8 Wall (above grade) U = 0.082 953 78.1 0.069 1,145 78.8 Floors over Crawlspace U = 0.000 0 0.0 0.029 384 11.1 Slab on Grade F = 0.000 0 0.0 0 0.0 Below Grade Wall U = 0.185 1,515 280.3 0.034 1,515 51.5 Below Grade Slab F = 0.430 130 55.9 0.556 130 72.3 * Values from user-defined baseline Baseline UA Total 594.8 Proposed UA Total 365.9 Required Credits 8.0 Proposed Credits 3.0 from Tables 406.2 and 406. UA Percent Reduction Calculate %UA reduction based on Addition UA Reduction 228.9 Table R406.2 Energy Equalization Credits Fuel Normalization Energy Credits Total Credits System No. Full Description Select System Type Credits (406.2) (406.3) (406.2 & 406.3) For heating system using a heat pump that meets federal standards for the equipment listed in Table C403.3.2(2) or Table C403.3.2(9) OR Air to Water heat Variable Refrigerant Heat Pump or Air-to- 4 3.0 0.0 3.0 pump units that are configured to provide both heating and cooling and are rated in Water Heat Pump accordance with AHRI 550/590 Table R406.3 Energy Credits Option No. Category Select Options Energy Credits Brief Description of Selected Options* 1 Efficient Building Envelope Not Selected 0.0 - 2 Air Leakage Control and Efficient Ventilation 3.1 -3.10 High Efficiency HVAC 0.0 WSU_C32021_20240507a~Master.xlsm 1/23/2025 4 WSU Code Compliance Calculator, WSEC 2021 3.11 High Efficiency HVAC: Smart Thermostat 0.0 4 High Efficiency HVAC Distribution System 0.0 5.1 Efficient Water Heating: Drain Heat Recovery 0.0 5.2 Efficient Water Heating: Compact Hot Water Distribution 0.0 5.3-5.8 Efficient Water Heating 0.0 6 Renewable Electric Energy kWh 0.0 7 Appliance Package 0.0 Energy Credits 0.0 *Refer to WSEC 2015 Table R406.2 for complete option descriptions and requirements WSU_C32021_20240507a~Master.xlsm 1/23/2025 5 WSU Code Compliance Calculator, WSEC 2021 THERMAL ENVELOPE DETAILS - Proposed Design Conditioned Floor Area of Addition, Proposed Design 2,199 sq. ft Classification Medium Dwelling Unit Notes New Addition with Upgrades to Existing Envelope Exterior Doors Plan Component Door Width Height ID Description Ref. U Qt. Feet Inch Feet Inch Area UA Exempt 00.0 New Code Baseline, U=0.30 - 0.30 2 6 6 8 80 24.0 New Code Baseline, U=0.30 - 0.30 1 3 6 8 20 6.0 00.0 00.0 00.0 00.0 00.0 00.0 00.0 00.0 Sum of Area and UA 100 30.0 0 0 Exterior Doors Area Weighted U 0.300 Overhead Glazing Plan Component Glazing Width Height ID Description Ref. U Qt. Feet Inch Feet Inch Area UA New 2021 U-factor Baseline (Table R402.1.2) Table R402. 0.50 1 2 4 8.0 4 - - - - Sum of Area and UA 8.0 4 0 0 Overhead Glazing Area Weighted U 0.500 Vertical Glazing Schedule Rows to Show 12 Plan Component Glazing Width Height ID Description Ref. U Qt. Feet Inch Feet Inch Area UA Exempt - - - 1New U=0.30 (Code Baseline) Table 406.2 0.30 15 2 6 4 6 168.8 50.63 2New U=0.30 (Code Baseline) Table 406.2 0.30 3 2.00 0 3 6 21.0 6.30 3New' U=0.30 (Code Baseline) Table 406.2 0.30 1 4 0 3 6 14.0 4.20 4New U=0.30 (Code Baseline) Table 406.2 0.30 1 1 6 5 0 7.5 2.25 5New U=0.30 (Code Baseline) Table 406.2 0.30 1 3 0 1 6 4.5 1.35 6New U=0.30 (Code Baseline) Table 406.2 0.30 1 5 0 3 6 17.5 5.25 7New U=0.30 (Code Baseline) Table 406.2 0.30 1 3 0 3 0 9.0 2.70 8New U=0.30 (Code Baseline) Table 406.2 0.30 2 3 0 1 6 9.0 2.70 9 - - 10 - - 11 - - 12 - - Sum of Area and UA 251.3 75.4 0 Vertical Glazing Area Weighted U 0.300 Vertical Glazing and Doors Area Weighted U 0.300 Flat/Vaulted Ceilings Plan Component Attic ID Description Ref. U Area UA New R30 batt Vault vented 2x12 24oc 10-7 0.033 384 12.7 UpgradedR49 blown Attic STD baffled (2018 Code Baseline, 1.1-110-7 0.027 1,115 30.1 Sum of Area and UA 1,499 42.8 0 WSU_C32021_20240507a~Master.xlsm 1/23/2025 6 WSU Code Compliance Calculator, WSEC 2021 Walls (Above Grade) Plan Component Wall ID Description Ref. U Net Area UA New R21 cavity+R5 foam STD 2X6W Lap 10-5 0.043 387 17 Existing R13 cavity+R0 foam STD 2X4W Lap 10-5 0.082 758 62 Sum of Area and UA 1,145 79 0 WSU_C32021_20240507a~Master.xlsm 1/23/2025 7 WSU Code Compliance Calculator, WSEC 2021 Floor (over crawl or exterior) Plan Component Floor UA ID Description Ref. U Area New R30 vented Joist (Code Baseline) 10-3 0.029 384 11 Sum of Area and UA 384 11 0 Slab on Grade (less than 2 feet below grade) Plan Component Slab Slab ID Description Ref. F Perim FP Sum of Perimeter and FP 00 0 Below Grade Walls and Slabs Plan Component Slab Wall Wall Wall Slab Slab Slab ID Description Depth Ref. U Area UA F Perim UA UpgradedR13 Batt + R5 ci 7' depth WSU 0.03 1,515 51.5 0.556 130 72 Sum of Area, Length and UA 1,515 51.5 130 72 0 Links to Download Forms, Checklists and Other Resources Link Compliance Certificate Compliance Certificate Instructions Insulation Certificate for Residential New Construction Insulation Certificate Duct Testing Affadavits Existing Construction Affidavit, Existing New Construction Affidavit, New Prescriptive Checklist for 2018 WSEC Prescriptive Checklist Alterations (Remodel) Worksheet Worksheet EER SEER2 COP HSPF2 Converter https://www.adicotengineering.com/eer-seer2-cop-hspf2-kwton-converter Show Ventilation Calculator? Show Ventilation Requirements Conditioned Floor Area 2,199 sq. ft. Number of Bedrooms 3 Run-Time Percent in Each 4-Hour Segment 50% Is the system Balanced? Unbalanced Is the system Distributed? Distributed Verify system meets definition of 'Distributed Whole-House Ventilation' Ventilation Code Section IRC, Chapter 15 Whole House Mechanical Ventilation Airflow Rate 138 CFM Show Distribution System Calculator? Show HVAC Thermal Distribution System Download RS-33 (2018) http://www.energy.wsu.edu/Documents/Duct%20Testing%20Standards%2 Is this a hydronic heating system? No Location of Ducts Conditioned Space Location of Air Handler Conditioned Space For Existing Construction: Are Any of These Exceptions True? Are ducts systems documented to have been previously sealed as confirmed No through field verification and diagnostic testing per RS-33? Is there less than 40 linear feet in unconditioned spaces? (not excepted under No WSEC 2021) Inconsistent with input above: Ducts located in conditioned space. Are existing duct systems constructed, insulated or sealed with asbestos? Yes Is the project an Addition less than 750 sf of conditioned floor area? Yes Is Duct Testing Required? No A maximum of 10 feet of return ducts and 5 feet of supply ducts are allowed to be located outside of the building thermal envelope, if insulated and sealed per R403.3.7. WSU_C32021_20240507a~Master.xlsm 1/23/2025 8 WSU Code Compliance Calculator, WSEC 2021 Show Heating System Sizing? Show Heating System Sizing - Proposed Design Try Out BetterBuiltNW's HVAC Sizing Tool: https://betterbuiltnw.com/resources/hvac-sizing-tool Nearest Weather Station Everett Paine AFB Indoor Design Temperature 70 F Outdoor Design Temperature 21 F Design Temperature Difference (∆T) 49 F Conditioned Floor Area of Addition, Proposed Design 2,199 ft2 Conditioned Volume 17,592 ft3 0.00 Leave blank to use default of 8.5 ft. ceiling height HVAC System Type Heat Pump Location of HVAC Distribution System Conditioned Space Sum of UA 366 Envelope Heat Load 17,930 Btu / Hour Sum of UA X ∆T Air Leakage Heat Load 9,310 Btu / Hour ((Volume X 0.6) X ∆T) X .018)) Building Design Heat Load 27,240 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 27,240 Btu / Hour For ducts located in unconditioned space: Sum of Building Heat Loss X 1.1 For ducts located in conditioned space or ductless: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 34,050 Btu / Hour Building and Duct Heat Loss X 1.25 for heat pumps 10.0 kW Building and Duct Heat Loss X 1.40 for all other systems WSU_C32021_20240507a~Master.xlsm 1/23/2025 9 WSU Code Compliance Calculator, WSEC 2021 Project Information Messages / Results * Small dwelling unit example Review of Baseline Required - UA Reduction = 434.92, compared to user-defined baseline UA. Check that this is required % reduction compared to Addit Contact Information Window area is 13% of floor area - -- -- * Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ. ANALYSIS SET UP What code compliance pathway are you using? User-Defined Baseline (Addition/Remodel/Alteration of Existing) Project Building Type? Addition Occupancy Type? R3 Single family homes and duplexes Code Version? WSEC 2021 WSEC-R Rev: Oct. 2023, https://www.sbcc.wa.gov/sites/default/files/2023-12/OT Classification: Addition 150 sf to 500 sf -- 384 sq. ft. Baseline Description: Existing Baseline - Baseline and proposed window areas are equal. About Your Selection: Up to 15 sf exempt window and 24 sf exempt door allowable. Enter baseline design details to right of proposed design below RESULTS - Comparison of Baseline and Proposed Design Component Performance, R occupancies Baseline Proposed Design U * Area UA U Area UA Doors U = 0.474 37 17.4 0.300 80 24.0 Overhead Glazing U = 0.500 16 8.0 0 0.0 Vertical Glazing U = 0.400 51 20.2 0.300 51 15.2 Flat/Vaulted Ceilings U = 0.049 1,115 54.6 0.033 384 12.7 Wall (above grade) U = 0.082 953 78.1 0.043 387 16.6 Floors over Crawlspace U = 0.000 0 0.0 0.029 384 11.1 Slab on Grade F = 0.000 0 0.0 0 0.0 Below Grade Wall U = 0.185 1,515 280.3 0 0.0 Below Grade Slab F = 0.430 130 55.9 0 0.0 * Values from user-defined baseline Baseline UA Total 514.5 Proposed UA Total 79.6 Required Credits 2.0 Proposed Credits 3.0 from Tables 406.2 and 406. UA Percent Reduction Calculate %UA reduction based on Addition UA Reduction 434.9 Table R406.2 Energy Equalization Credits Fuel Normalization Energy Credits Total Credits System No. Full Description Select System Type Credits (406.2) (406.3) (406.2 & 406.3) For heating system using a heat pump that meets federal standards for the equipment listed in Table C403.3.2(2) or Table C403.3.2(9) OR Air to Water heat Variable Refrigerant Heat Pump or Air-to- 4 3.0 0.0 3.0 pump units that are configured to provide both heating and cooling and are rated in Water Heat Pump accordance with AHRI 550/590 Table R406.3 Energy Credits Option No. Category Select Options Energy Credits Brief Description of Selected Options* 1 Efficient Building Envelope Not Selected 0.0 - 2 Air Leakage Control and Efficient Ventilation 3.1 -3.10 High Efficiency HVAC 0.0 WSU_C32021_20240507a~Master.xlsm 1/23/2025 4 WSU Code Compliance Calculator, WSEC 2021 3.11 High Efficiency HVAC: Smart Thermostat 0.0 4 High Efficiency HVAC Distribution System 0.0 5.1 Efficient Water Heating: Drain Heat Recovery 0.0 5.2 Efficient Water Heating: Compact Hot Water Distribution 0.0 5.3-5.8 Efficient Water Heating 0.0 6 Renewable Electric Energy kWh 0.0 7 Appliance Package 0.0 Energy Credits 0.0 *Refer to WSEC 2015 Table R406.2 for complete option descriptions and requirements WSU_C32021_20240507a~Master.xlsm 1/23/2025 5 WSU Code Compliance Calculator, WSEC 2021 THERMAL ENVELOPE DETAILS - Proposed Design Conditioned Floor Area of Addition, Proposed Design 384 sq. ft Classification Addition 150 sf to 500 sf Notes New Addition Exterior Doors Plan Component Door Width Height ID Description Ref. U Qt. Feet Inch Feet Inch Area UA Exempt 00.0 New Code Baseline, U=0.30 - 0.30 2 6 6 8 80 24.0 00.0 00.0 00.0 00.0 00.0 00.0 00.0 00.0 00.0 Sum of Area and UA 80 24.0 0 0 Exterior Doors Area Weighted U 0.300 Overhead Glazing Plan Component Glazing Width Height ID Description Ref. U Qt. Feet Inch Feet Inch Area UA - - - - - Sum of Area and UA 0.0 0 0 0 Overhead Glazing Area Weighted U Vertical Glazing Schedule Rows to Show 12 Plan Component Glazing Width Height ID Description Ref. U Qt. Feet Inch Feet Inch Area UA Exempt - - - 1New U=0.30 (Code Baseline) Table 406.2 0.30 2 2 6 4 6 22.5 6.75 2New U=0.30 (Code Baseline) Table 406.2 0.30 2 2.00 0 3 6 14.0 4.20 3New' U=0.30 (Code Baseline) Table 406.2 0.30 1 4 0 3 6 14.0 4.20 4 - - 5 - - 6 - - 7 - - 8 - - 9 - - 10 - - 11 - - 12 - - Sum of Area and UA 50.5 15.2 0 Vertical Glazing Area Weighted U 0.300 Vertical Glazing and Doors Area Weighted U 0.300 Flat/Vaulted Ceilings Plan Component Attic ID Description Ref. U Area UA New R30 batt Vault vented 2x12 24oc 10-7 0.033 384 12.7 Sum of Area and UA 384 12.7 0 WSU_C32021_20240507a~Master.xlsm 1/23/2025 6 WSU Code Compliance Calculator, WSEC 2021 Walls (Above Grade) Plan Component Wall ID Description Ref. U Net Area UA New R21 cavity+R5 foam STD 2X6W Lap 10-5 0.043 387 17 Sum of Area and UA 387 17 0 WSU_C32021_20240507a~Master.xlsm 1/23/2025 7 WSU Code Compliance Calculator, WSEC 2021 Floor (over crawl or exterior) Plan Component Floor UA ID Description Ref. U Area New R30 vented Joist (Code Baseline) 10-3 0.029 384 11 Sum of Area and UA 384 11 0 Slab on Grade (less than 2 feet below grade) Plan Component Slab Slab ID Description Ref. F Perim FP Sum of Perimeter and FP 00 0 Below Grade Walls and Slabs Plan Component Slab Wall Wall Wall Slab Slab Slab ID Description Depth Ref. U Area UA F Perim UA Sum of Area, Length and UA 0 0.0 0 0 0 Links to Download Forms, Checklists and Other Resources Link Compliance Certificate Compliance Certificate Instructions Insulation Certificate for Residential New Construction Insulation Certificate Duct Testing Affadavits Existing Construction Affidavit, Existing New Construction Affidavit, New Prescriptive Checklist for 2018 WSEC Prescriptive Checklist Alterations (Remodel) Worksheet Worksheet EER SEER2 COP HSPF2 Converter https://www.adicotengineering.com/eer-seer2-cop-hspf2-kwton-converter Show Ventilation Calculator? Hide Show Distribution System Calculator? Hide Show Heating System Sizing? Hide WSU_C32021_20240507a~Master.xlsm 1/23/2025 8 LIST OF DRAWINGS Sheet Number Sheet Name Current Revision 309 S DUNHAM AVE ADDITION A0.0 COVER PAGE A0.1 GENERAL NOTES A0.2 NOTES & SCHEDULES A1.1 SITE PLAN A2.0 REMODEL/ADDITION FLOOR PLANS A2.1 ELECTRICAL & MECHANICAL A2.2 ROOF PLAN A3.0 DEMOLITION PLAN A3.1 FOUNDATION & FRAMING PLAN A4.0 ELEVATIONS A4.1 ELEVATIONS AND SECTIONS A4.2 WALL SECTIONS AND STAIRS A5.0 3D EXTERIOR A5.1 3D EXTERIOR A5.2 3D INTERIOR VICINTY MAP PROJECT TEAM PROJECT INFORMATION PROJECT NAME: TONY AND HEIDI SMITH OWNER: TAX ID #: 00538300201300 TONY AND HEIDI SMITH LOCATION: 309 S DUNHAM AVE 309 S DUNHAM AVE ARLINGTON, WA 98223 ARLINGTON, WA 98223 PROJECT #: NOT ASSIGNED OTHER PERMITS: NONE DESIGNER/APPLICANT: ZONE: OLD TOWN RESIDENTIAL DISTRICT GARRETT CHARLSON LOT SIZE: .21 ACRES OR 9147SF SNOVALLEY COTTAGES USE: SINGLE FAMILY RESIDENTIAL PO BOX 754 PROJECT DESCRIPTION: REMODEL AND ADDITION OF EXISTING SFR, ADDITION DUVALL, WA 98019 TO REAR OF HOUSE AND FRONT PORCH, BEDROOM p425.518.0036 COUNT TO REMAIN THE SAME Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. LEGAL DESCRIPTION: PALMER ADD TO ARLINGTON BLK 002 D-00- ALL LOTS No. GEOTECHNICAL ENGINEER: 13 & 14 N/A STRUCTURAL ENGINEER: COLIN ANYAN VIRTUS ENGINEERING SPRINKLERS: N/A PO BOX 30351 ECA: N/A SPOKANE, WA 99223 Issue Date SEPTIC: N/A - CITY SEWER p509.220.8766 LAND USE CODE COMPLIANCE ZONE: OLD TOWN RESIDENTIAL DISTRICT (OTRD) COVER PAGE Drawn by:Author IMPERVIOUS COVERAGE: LOT AREA: 9147 SF EXISTING SFR (OVERHANGS): 1597 SF Scale: EXISTING GARAGE (OVERHANGS): 616 SF EXISTING DRIVEWAY HARDSCAPE : 528 SF EXISTING WALKWAY HARDSCAPE : 150 SF ALLOWED LOT COVERAGE - NOT DEFINED: EXISTING LOT COVERAGE: 2891 SF NEW PROPOSED ADDITION (OVERHANGS): 767 SF NEW TOTAL LOT COVERAGE: 2891 SF + 767 SF = 3658SF REQ. SETBACKS: FRONT (STREET): AVERAGE TO ADJACENT LOTS CALC-NORTH 6.76' SOUTH SIDES (INTERIOR): 7.36, AVG. 7.06' REAR: 5 FEET 5 FEET HEIGHT LIMIT: BASE HEIGHT: 24' MAX TO EAVE ARLINGTON, WA 309 S DUNHAM AVE PROPOSED MAX. BUILDING HEIGHT: 9' TO EAVE AND 15' TO RIDGE 309 S DUNHAM AVE ADDITION Job No.: 23-15 A0.0 GENERAL DESIGN NOTES WSEC ENERGY NOTES MECHANICAL NOTES PLUMBING NOTES 1. COMPLY WITH CITY OF ARLINGTON CODES, 2021 IRC (INTERNATIONAL RESIDENTIAL CODE), 2021 WSEC ENERGY NOTES 1. ALL PLUMBING WORK IS TO BE BIDDER DESIGNED AND SHALL COMPLY WITH ALL WASHINGTON STATE ENERGY CODE, AND ALL APPLICABLE CODES AND ORDINANCES OF THE LOCAL 1. DESIGN TEMPERATURE: 49 DEGREES (70 INDOOR-21 OUTDOOR) 1. ALL MECHANICAL WORK TO BE BIDDER DESIGNED AND SHALL COMPLY WITH ALL APPLICABLE APPLICABLE CODES AND ORDINANCES. JURISDICTION AND THE STATE OF WASHINGTON. CODE: 2021 WASHINGTON STATE ENERGY CODE COMPLIANCE: USER DEFINED BASELINE- CODES. ADDITION/REMODEL/ALTERATION OF EXISTING 2. PROVIDE PRESSURE RELIEF VALVE FOR HOT WATER TANK. DRAIN TO THE OUTSIDE OF 2. DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS, REFER TO DETAILS FOR LOCATION OF ITEMS NOT 2. THE MECHANICAL WORK MUST ADHERE TO THE REQUIREMENTS OF THE DESIGN DRAWINGS. THE BUILDING WITH DRAIN END NOT MORE THAN 2 FEET NOR LESS THAN 6 INCHES DIMENSIONED ON PLANS, VERIFY UNKNOWN DIMENSIONS WITH DESIGNER. FROM THE GROUND, POINTING DOWN. BASELINE INSULATION AND FENESTRATION PROVIDED 3. VENTILATION SHALL BE IN CONFORMANCE WITH WAC 51-11 AND WAC 51-13, 2021 IRC CHAPTER 3. IT IS THE RESPONSIBILITY OF CONTRACTOR TO DO DUE DILIGENCE RELATED TO EXISTING SITE EXISTING STRUCTURE 15, TABLES M1507.4 AND M1507.3.3(1). 3. HOT WATER HEATERS SHALL BE ELEVATED PER 2021 IRC P2801.6. CONDITIONS PRIOR TO SUBMITTING PLANS FOR BID. WINDOW U FACTOR 0.40 (ESTIMATED) .30 4. HOT WATER TANKS SHALL BE STRAPPED OR ANCHORED AT POINTS WITHIN THE UPPER 4. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION, WHERE CONDITIONS ARE NOT 1/3 AND LOWER 1/3 TO RESIST EARTHQUAKE MOTION. SPECIFICALLY INDICATED BUT ARE OF SIMILAR CONSTRUCTION OF THOSE SHOWN, SIMILAR DETAILS CAN SKYLIGHT U FACTOR .50 .30 BE USED SUBJECT TO REVIEW AND APPROVAL OF DESIGNER AND STRUCTURAL ENGINEER. 5. PROVIDE AN APPROVED BACK-FLOW DEVICE AT ALL HOSE BIBS. GLAZED FENESTRATION SHGC N/A N/A RATED ASSEMBLIES - N/A 5. ALL WOOD FRAMING DETAILS NOT SHOWN SHALL BE CONSTRUCTED PER THE MINIMUM STANDARDS SET 6. ADDITIONAL NOTES LOCATED ON ELECTRICAL MECHANICAL PLAN SHEETS. FORTH IN THE 2021 IRC. CEILING R-19 R-49 FLAT R-30 VAULT 6. VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THIS CONTRACT OR BY OTHERS. ALL ABOVE GRADE WALL R-13 R-13 OLD AND R21+R6.6Ci NEW ELECTRICAL NOTES ROUGH-INS SHALL BE APPROVED AND FIREBLOCKING SHALL BE INSTALLED PRIOR TO FRAMING INSPECTION. BELOW GRADE WALL NOT INSULATED R13 + R5Ci 1. ALL ELECTRICAL WORK IS TO BE BIDDER DESIGNED AND SHALL COMPLY WITH ALL APPLICABLE 7. BUILDING SYSTEMS NOT DETAILED SHALL BE INSTALLED PER MANUFACTURERS REQUIREMENTS. NOTIFY FLOORS NOT INSULATED R-30 CODES AND ORDINANCES. INCLUDED ELECTRICAL PLAN IS FOR LAYOUT AND DESIGN DESIGNER OF ANY CONFLICTS. REFERENCE, ALL LOCATIONS TO BE FIELD VERIFIED WITH CONTRACTOR AND/OR OWNER PRIOR SLAB ON GRADE NOT INSULATED NOT INSULATED TO INSTALLATION. 8. PLUMBING AND MECHANICAL DRAWINGS ARE SUPPLEMENTARY TO THE TO THE DESIGN DRAWINGS. IT IS THE RESPONSIBILITY OF EACH OF THE CONTRACTORS TO THE DESIGN DRAWINGS PRIOR TO INSTALLATION GLAZING AREA UNLIMITED UNLIMITED 2. ADDITIONAL NOTES LOCATED ON ELECTRICAL AND MECHANICAL PLAN SHEETS. OF THEIR WORK, ANY CONFLICTS BETWEEN THE TWO SHALL BE BROUGHT TO THE OWNERS ATTENTION IN WRITING. DOORS .50 (ESTIMATED) .30 VENTILATION NOTES 9. CONTRACTOR TO PROVIDE TEMPORARY BRACING FOR ALL STRUCTURE AND COMPONENTS UNTIL CONNECTIONS HAVE BEEN MADE. 1. SYSTEM TYPE: WHOLE HOUSE FAN ON TIMER 10. ALL GLAZING IN HAZARDOUS LOCATIONS, DEFINED BY THE 2021 IRC R308.4, SHALL BE SAFETY GLAZING IDENTIFIED IN THE FLOOR PLANS AND GLAZING SCHEDULE. 2. SPECIFICS: SEE MECHANICAL PLANS, SHEET A2.1 11. PROVIDE FOOTING BEARING PER GEOTECHNICAL ENGINEER RECOMMENDATIONS. WSEC ENERGY CREDIT NOTES 3. ADDITIONAL NOTES LOCATED ON FLOOR PLAN SHEETS 12. "FINISH FLOOR" REFERS TO: • THE TOP OF SLAB AT BASEMENT CREDIT REQUIREMENTS PER R406.3 DWELLING SIZE: ADDITIONS 150-500SF CREDITS REQUIRED: 2 • TOP OF FLOOR SHEATHING AT MAIN FLOOR CREDITS PROVIDED: 3 • TOP OF SHEATHING AT UPPER FLOOR (3 CREDITS) HEATING OPTION 4 13. VERIFY SIZE AND LOCATION OF AND PROVIDE ALL OPENINGS THROUGH FLOORS AND WALLS, FURRING, VARIABLE REFRIGERANT HEAT PUMP OR AIR-TO-WATER HEAT PUMP DEFERRED SUBMITTALS ANCHORS, INSERTS, ROUGH BUCKS AND BACKING FOR SURFACE MOUNTED ITEMS. FOR HEATING SYSTEM USING A HEAT PUMP THAT MEETS FEDERAL STANDARDS FOR THE 14. PROVIDE FURRING AS REQUIRED TO CONCEAL MECHANICAL AND ELECTRICAL WORK IN ALL FINISHED EQUIPMENT LISTED IN TABLE C403.3.2(2) OR TABLE C403.3.2(9) OR AIR TO WATER HEAT AREAS. PUMP UNITS THAT ARE CONFIGURED TO PROVIDE BOTH HEATING AND COOLING AND ARE RATED IN 1. HEAT PUMP SPECIFICATIONS ACCORDANCE WITH AHRI 550/590 2. TRUSS DRAWINGS IF APPLICABLE 15. UNLESS OTHERWISE NOTED, ALL PLAN DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE. 16. EXTERIOR WALLS SHALL BE 2X6 STUDS AT 24" O.C. AND INTERIOR WALLS SHALL BE 2X4 STUDS AT 24" TOTAL CREDITS: 3 O.C., UNLESS NOTED OTHERWISE. 17. ALL SWINGING DOORS NOT LOCATED BY DIMENSIONS ON PLANS, INTERIOR ELEVATIONS, OR DETAILS SHALL BE 4-1/2" FROM FACE OF STUD TO EDGE OF ROUGH OPENINGS OR CENTERED BETWEEN ROOM PARTITIONS AS SHOWN. 18. PLANS ARE DRAWN ASSUMING THE FOLLOWING ROUGH OPENINGS: EXTERIOR DOOR WIDTH: NOMINAL SIZE + 2" (VERIFY WITH DESIGNER) WINDOW WIDTH: NOMINAL SIZE + 0" (VERIFY WITH DESIGNER) WINDOW HEIGHT: NOMINAL SIZE + 0" (VERIFY WITH DESIGNER) INTERIOR SWINGING DOORS: NOMINAL SIZE Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. +2". INTERIOR POCKET DOORS: PANEL SIZE + 1" BI-PASS DOORS: NOMINAL SIZE +0". 19. REFER TO CABINET DESIGNER PLANS FOR CABINET AND COUNTER LENGTHS, DIMENSIONS, No. COUNTERTOP MATERIALS AND DETAIL REFERENCE. VERIFY ALL EXISTING DIMENSIONS BEFORE ORDERING AND PRIOR TO INSTALLATION. 20. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR EXPOSED TO THE WEATHER SHALL BE PRESSURE TREATED WITH AN APPROVED PRESERVATIVE OR DECAY RESISTANT NATURALLY DURABLE WOOD. FASTENERS FOR PT MATERIALS SHALL BE HOT DIPPED GALVANIZED STEEL, STAINLESS STEEL SILICON BRONZE COPPER OR APPROVED FASTENER FOR PRESSURE TREATED CONTACT. 21. ALL WOOD LESS THAN 8" FROM THE GROUND OR 2" FROM EXTERIOR CONCRETE (SLABS, STEPS, AND SIMILAR HORIZONTAL SURFACES) AND EXPOSED TO WEATHER SHALL BE NATURALLY DURABLE OR PRESSURE TREATED PER 2021 IRC R317. 22. PROVIDE FIRE BLOCKING VERTICALLY AT CEILING AND FLOOR LEVELS AND HORIZONTALLY AT INTERVALS NOT TO EXCEED 10 FEET AD AS REQUIRED FOR CONCEALED SPACES PER 2021 IRC R302.11 AND R302.12. Issue Date 23. ALL EMERGENCY ESCAPES AND RESCUE OPENINGS SHALL MEET THE REQUIREMENTS OF 2021 IRC R310. 24. ROOF VENTILATION SHALL MEET THE REQUIREMENTS OF 2021 IRC R806. 25. WEATHER PROOFING SHALL MEET THE REQUIREMENTS OF 2021 IRC R903. 26. GUARDRAILS AND OPEN RAILINGS SHALL MEET THE REQUIREMENTS OF 2021 IRC R312. GENERAL NOTESDrawn by:Author GEOTECHNICAL NOTES 1. REPORT NOT REQUIRED Scale: 12" = 1'-0" ARLINGTON, WA 309 S DUNHAM AVE 309 S DUNHAM AVE ADDITION Job No.: 23-15 A0.1 ROOMS SCHEDULE ALL NOTES PROJECT LEGEND(S) ROOM NAME AREA COMMENTS NO. DESCRIPTION View Type Count (N) BEDROOM 2 123 SF 1 (N) ASPHALT ROOF ELEVATION 2 GENERAL SYMBOLS WALL ASSEMBLIES (N) BATH 47 SF 2 WRAP POSTS IN PWW ELEVATION 3 2X4 INTERIOR WALL (N) DINING 196 SF 3 HARDIE LAP SIDING-8" REVEAL, VERIFY WITH OWNER ELEVATION 3 • 1/2 GYPSUM (N) KITCHEN 252 SF 4 TREX DECK FASCIA ELEVATION 3 1 PLAN NOTE W1 • 2X4" DF (N) BONUS ROOM 564 SF 5 1X6 PWW TRIM OR HARDIE TRIM ELEVATION 1 • 1/2 GYPSUM SPOT ELEVATION (N) BATH 43 SF 6 (N) 5" GUTTER ELEVATION 1 • INSULATE AROUND CL. 24 SF CLOSET, TYP. 7 TREX DECKING OR EQUIV. ELEVATION 2 BATHROOMS & BEDROOMS E E ELECTRIC (N) MECH. 57 SF 8 1X10 PWW TRIM OR HARDIE TRIM ELEVATION 1 2X6 INTERIOR WALL (N) OFFICE 47 SF 1 EXISTING SEWER ~5' ABOVE FFE FLOOR PLAN 1 W W WATER • 1/2 GYPSUM (N) BEDROOM 3 80 SF 2 EXISTING ELECTRICAL PANEL-150 AMP, UPGRADE TO 200 AMP FLOOR PLAN 1 W2 • 2X6" DF DS • 1/2 GYPSUM (N) STORAGE 54 SF 1 VENT HOOD MIN. 100CFM MEP 1 DOWNSPOUT • INSULATE AROUND CL. 13 SF CLOSET, TYP. 2 BATHROOM EXHAUST FAN MIN. 50CFM MEP 2 BATHROOMS & BEDROOMS LINEN 4 SF 3 PANASONIC WHISPER 50/80/110 ON TIMER MEP 1 HD HEAT DETECTOR 2X4 EXTERIOR WALL R-15: (E) MASTER BEDROOM 135 SF 4 RHEEM PROTERRA-INTAKE AND EXHAUST TO EXTERIOR MEP 1 • 1/2 GYPSUM (N) BATHROOM 36 SF 5 MITSUBISHI HYPERHEAT HEAT PUMP MEP 1 S/CM SMOKE/CO2 DETECTOR • 2X4" DF W3 CL. 12 SF CLOSET, TYP. 6 MITSUBISHI AIR HANDLER IN MECH. MEP 1 • BLOWN IN CELLULOSE OR BATT R-15 SHOWER/TOILET 34 SF 1 SOLAR READY ZONE ROOF 1 • SIDING PER OWNER SPEC. (N) GREAT ROOM 478 SF 2 DOWNSPOUT TO TIGHTLINE TO DRYWELL ROOF 2 2199 SF 3 30-YEAR ASPHALT ROOF ROOF 1 Grand total: 18 2199 SF 4 DOWNSPOUT TO TIGHTLINE TO RAIN GARDEN OR SWALE ROOF 3 2X6 EXTERIOR WALL R-26: 5 OVERFRAME ROOF 4 • 1/2 GYPSUM OVER EXISTING W4 • 2X6" DF ROOF PER STRUC. SITE PLAN LEGEND • BLOWN IN CELLULOSE OR BATT R-20 OVERFRAME OVER EXISTING ROOF PER STRUC. • 1 1/2" ZIP R-SHEATHING R-6 DOOR SCHEDULE • SIDING PER OWNER SPEC. DOOR ROOM DOOR NO. DISTURBED AREA - 2x4 BASEMENT WALL: TYPE FROM TO HEIGHT WIDTHAREA Phase Created • NO WATERPROOF COATING ON CONCRETE C104 - STAKE & WIRE FENCING • 2" RIGID EPS FOAM BASEMENT FF W5 • 2X4 STUD WALL W/ MINERAL WOOL INSUL. R-15 SOLID CORE INTERIOR (N) BONUS (N) BONUS ROOM 80" 30" 17 SF Existing C233 SILT FENCE OR MULCH BERM • 1/2" GYPSUM DEMO ROOM DS • NON-PVA WALL PRIMER SOLID CORE INTERIOR (N) BONUS (N) BONUS ROOM 80" 30" 17 SF Existing DOWNSPOUT • LOW OR NO VOC LATEX PAINT DEMO ROOM D19 SOLID CORE INTERIOR (N) MECH. (N) BONUS ROOM 80" 30" 17 SF New 1 PLAN NOTE (E) BASEMENT WALL: SOLID CORE INTERIOR (N) BONUS (N) STORAGE 80" 28" 16 SF New W6 • 6" POURED CONCRETE WALL D16 SPOT ELEVATION ROOM SOLID CORE INTERIOR (N) BONUS (N) OFFICE 80" 30" 17 SF New E E D20 ELECTRIC ROOM SOLID CORE INTERIOR (N) BONUS (N) BEDROOM 3 80" 30" 17 SF New W W WATER D18 ROOM FLOOR ASSEMBLIES D17 SOLID CORE INTERIOR LINEN (N) BONUS ROOM 80" 20" 11 SF New D21 BI-PASS CLOSET CL. (N) BEDROOM 3 80" 60" 33 SF New EXISTING SLAB ON GRADE CONDITIONED: • 4" CONCRETE SOLID CORE INTERIOR (N) BONUS (N) BONUS ROOM 80" 30" 17 SF New D15 MEP LEGEND • APPLY SELF LEVELER, PREP PER MANUF. ROOM RECOMMENDATIONS D14 SOLID CORE INTERIOR CL. (N) BONUS ROOM 80" 34" 19 SF New FL1 • UNDERSLAB CONDITIONS UNKNOWN D13 SOLID CORE INTERIOR (N) BATH (N) BONUS ROOM 80" 30" 17 SF New CEILING LIGHT • RECOMMENDED NO CARPET AT BASEMENT 196 SF • INSTALL VAPOR RETARDER UNDER FLOORING MAIN LEVEL DEMO SOLID CORE INTERIOR (N) GREAT ROOM (N) GREAT ROOM 80" 24" 13 SF Existing WALL LIGHT FLOOR OVER CRAWLSPACE: DEMO SOLID CORE INTERIOR (N) GREAT ROOM CL. 80" 28" 16 SF Existing • FINISH FLOORING PER OWNER SPEC. Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. FL2 • 3/4 T&G FLOOR SHEATHING SOLID CORE INTERIOR (N) GREAT ROOM (E) MASTER 80" 30" 17 SF Existing CAN LIGHT • 11 7/8 TJI D8 BEDROOM • BATT INSULATION R-30 No. DEMO BI-PASS CLOSET (N) BEDROOM 2 (N) BEDROOM 2 80" 60" 33 SF Existing • VENTED CRAWLSPACE BI-PASS CLOSET (E) MASTER 80" 72" 40 SF Existing SIGLE OUTLET • 10MIL VAPOR BARRIER OVER GROUND D9 BEDROOM DEMO SOLID CORE INTERIOR (N) GREAT ROOM (N) GREAT ROOM 80" 30" 17 SF Existing DUPLEX OUTLET FLOOR OVER CONDITIONED: • FINISH FLOORING PER OWNER SPEC. DEMO SOLID CORE INTERIOR (N) GREAT ROOM (N) BEDROOM 2 80" 30" 17 SF Existing FL3 • 3/4 T&G FLOOR SHEATHING SWITCH DEMO SOLID CORE INTERIOR SHOWER/TOILET (N) BEDROOM 2 80" 24" 13 SF Existing • 2X8 ROUGH SAWN FLOOR JOISTS D6 SOLID CORE INTERIOR (N) GREAT ROOM (N) BEDROOM 2 80" 30" 17 SF Existing • 5/8 GYPSUM 3 SWITCH - 3 WAY D1 EXTERIOR INSULATED (N) GREAT ROOM 80" 36" 20 SF New D7 SOLID CORE INTERIOR (N) GREAT ROOM (N) GREAT ROOM 80" 30" 17 SF New EXTERIOR PATIO FULL (N) DINING 80" 72" 40 SF New R OUTLET 220V SEE SPECIFIC EQUIPMENT D3 SPEC. IF AVAIL. LITE ROOF ASSEMBLIES EXTERIOR PATIO FULL (N) DINING 80" 72" 40 SF New FLOOR OUTLET D2 LITE D11 POCKET DOOR SHOWER/TOILET (N) BATHROOM 80" 30" 17 SF New HRVB HRV BOOSTER SWITCH VENTED ROOF R-38: Issue Date D4 SOLID CORE INTERIOR (N) GREAT ROOM (N) BATH 80" 30" 17 SF New • 30-YEAR ASPHALT ROOFING D10 BI-PASS CLOSET (N) BATHROOM CL. 80" 60" 33 SF New • WRB WATER-30# TAR PAPER PLUMBING WALL (VERIFY FIXTURE R1 D12 BI-PASS CLOSET (N) BEDROOM 2 80" 60" 33 SF New LOCATION WITH CABINETRY &/OR • 1/2" PLYWOOD SHEATHING D5 SOLID CORE INTERIOR (N) GREAT ROOM 80" 32" 18 SF New PRODUCT SPEC. • 2X OR LVL RAFTERS PER STRUC. • VENTED RIDGE D22 SOLID CORE INTERIOR (N) GREAT ROOM (N) BEDROOM 2 80" 30" 17 SF New • INSULATION TO MIN. R-38 W/BAFFLES 433 SF • 5/8" GYPSUM Drawn by:Author VENTED ROOF OVER UNCONDITIONED: NOTES & SCHEDULES WINDOW SCHEDULE • 30-YEAR ASPHALT ROOFING • WRB WATER-30# TAR PAPER R2 • 1/2" PLYWOOD SHEATHING MARK LOCATION STYLE SIZE (W x H) AREA U-VALUE UA SILL HEIGHT TEMPERED COMMENTS ROOF PLAN LEGEND • 2X OR LVL RAFTERS PER STRUC. • VENTED RIDGE F1 (N) DINING CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-2" YES • SOFFIT-T AND G PINE OR EQUIV. F2 (N) DINING CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-2" YES GUTTER (DOUBLE LINE) • EXTERIOR GRADE PAINT OR STAIN Scale: F3 (N) KITCHEN CASEMENT 2'-0" x 3'-6" 7 0.3 2.100 3'-0" VENT-FIXED-VENT 1/8" = 1'-0" F4 (N) KITCHEN FIXED 4'-0" x 3'-6" 14 0.3 4.200 3'-0" VENT-FIXED-VENT DOWNSPOUT LOCATION DS F5 (N) KITCHEN CASEMENT 2'-0" x 3'-6" 7 0.3 2.100 3'-0" VENT-FIXED-VENT F6 (N) GREAT ROOM FIXED 2'-6" x 4'-6" 11 0.3 3.375 2'-6" SOLAR READY AREA F7 (N) GREAT ROOM CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-6" VENT-FIXED-VENT F8 (N) GREAT ROOM FIXED 2'-6" x 4'-6" 11 0.3 3.375 2'-6" VENT-FIXED-VENT BUILDING OUTLINE F9 (N) GREAT ROOM CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-6" VENT-FIXED-VENT F10 (N) GREAT ROOM CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-6" VENT-FIXED-VENT F11 (N) GREAT ROOM FIXED 2'-6" x 4'-6" 11 0.3 3.375 2'-6" VENT-FIXED-VENT F12 (N) GREAT ROOM CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-6" VENT-FIXED-VENT F13 (N) GREAT ROOM FIXED 1'-6" x 5'-0" 8 0.3 2.250 1'-8" YES F14 (N) BATH AWNING 3'-0" x 1'-6" 5 0.3 1.350 5'-6" YES VENT-FIXED-VENT F15 (N) BEDROOM 2 CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-6" VENT-FIXED-VENT F16 (N) BEDROOM 2 FIXED 2'-6" x 4'-6" 11 0.3 3.375 2'-6" VENT-FIXED-VENT F17 (N) BEDROOM 2 CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-6" EGRESS F18 (N) BEDROOM 2 FIXED 2'-6" x 4'-6" 11 0.3 3.375 2'-6" FIXED-FIXED F19 (N) BEDROOM 2 FIXED 2'-6" x 4'-6" 11 0.3 3.375 2'-6" FIXED-FIXED F20 SHOWER/TOILET CASEMENT 2'-0" x 3'-6" 7 0.3 2.100 3'-6" YES F21 (E) MASTER CASEMENT 2'-6" x 4'-6" 11 0.3 3.375 2'-6" EGRESS BEDROOM F22 (E) MASTER SLIDER 5'-0" x 3'-6" 18 0.3 5.250 3'-5 1/2" EGRESS BEDROOM F23 (N) BEDROOM 3 CASEMENT 3'-0" x 3'-0" 9 0.3 2.700 3'-8" EGRESS F24 (N) OFFICE AWNING 3'-0" x 1'-6" 5 0.3 1.350 5'-7" 309 S DUNHAM AVEARLINGTON, WA F25 (N) BONUS ROOM AWNING 3'-0" x 1'-6" 5 0.3 1.350 5'-7" TOTAL: 25 251 75.375 309 S DUNHAM AVE ADDITION Job No.: 23-15 A0.2 POWER POLE ALLEYWAY 76'-0" 12'-0" VICINTY MAP 5'-0" SIDE YARD SETBACK 41'-7 5/8" TO PL 5'-0" REAR YARD SETBACK 5'-0" SIDE YARD SETBACK OVERHEAD POWER LINE 1 9 INTERNAL ORIGIN (0,0,0) I 3'-0" TO PL PROPOSED ADDITION2 34 5 7 8 H G EXISTING (E) ELECTRICAL PROPOSED ADDITION GARAGE METER BASE 120'-0 1/8" TO REMAIN F 27'-0" GAS E 22'-0" (E) GAS LINE LOCATION TO METER, METER TO BE REMOVED EXISTING 3'-1 1/4" PROJECT INFORMATION BY UTILITY, LINE ABANDONED. 3-BED RESIDENCE Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. PROJECT NAME: TONY AND HEIDI SMITH D No. TAX ID #: 00538300201300 C LOCATION: 309 S DUNHAM AVE 10'-7 1/2" TO PL FFE = 171.33 20'-6" ARLINGTON, WA 98223 B PROJECT #: NOT ASSIGNED 6 OTHER PERMITS: NONE A ZONE: OLD TOWN RESIDENTIAL DISTRICT 10 8'-2" 41'-0 1/4" LOT SIZE: .21 ACRES OR 9147SF 6'-1"AA PROPOSED 7'-0 3/4" USE: SINGLE FAMILY RESIDENTIAL EXISTING Issue Date PROJECT DESCRIPTION: REMODEL AND ADDITION OF EXISTING SFR, ADDITION 14'-1" PROPOSED PORCH DRIVEWAY TO REAR OF HOUSE AND FRONT PORCH, BEDROOM 22'-7 1/4" TO PL (E)WALKWAY 13'-9 1/8" 12'-0" COUNT TO REMAIN THE SAME 170'-0" 13'-5 1/2" 13'-1 7/8" SITE PLAN LEGAL DESCRIPTION: PALMER ADD TO ARLINGTON BLK 002 D-00- ALL LOTS 4'-11 3/4" AVG. SETBACK ADJACENT Drawn by:Author 13 & 14 ADJACENT PARCEL SETBACK TO ROOF OH ADJACENT PARCEL SETBACK TO ROOF OH LAND USE CODE COMPLIANCE OLD TOWN RESIDENTIAL DISTRICT (OTRD) (E) SIDEWALK ZONE: 7'-4" Scale: WATER METER LOC. APPROX. SEWER LINE LOC. As indicated IMPERVIOUS COVERAGE: PER SIDE SEWER AS BUILT DEPTH ~2' AT HOUSE, 8' AT PROPERTY LINE ON DUNHAM LOT AREA: 9147 SF 18'-0" EXISTING SFR (OVERHANGS): 1597 SF SOUTH DUNHAM AVE EXISTING GARAGE (OVERHANGS): 616 SF EXISTING DRIVEWAY HARDSCAPE : 528 SF NORTH EXISTING WALKWAY HARDSCAPE : 150 SF 36'-0" ALLOWED LOT COVERAGE - NOT DEFINED: EXISTING LOT COVERAGE: 2891 SF NEW PROPOSED ADDITION (OVERHANGS): 767 SF NEW TOTAL LOT COVERAGE: 2891 SF + 767 SF = 3658SF 1 SITE PLAN REQ. SETBACKS: A4.0 1" = 10'-0" FRONT (STREET): AVERAGE TO ADJACENT LOTS CALC-NORTH 6.76' SOUTH SIDES (INTERIOR): 7.36, AVG. 7.06' ARLINGTON, WA 309 S DUNHAM AVE REAR: 5 FEET SITE PLAN KEY NOTES SITE PLAN LEGEND EXPOSED SOILS SHALL BE WORKED DURING THE WEEK 5 FEET NO. DESCRIPTION UNTIL THEY HAVE BEEN STABILIZED. SOIL STOCKPILES HEIGHT LIMIT: WILL BE LOCATED WITHIN THE DISTURBED AREA SHOWN ON THE SWPPP. SOIL EXCAVATED FOR THE DISTURBED AREA - 309 S DUNHAM AVE ADDITION BASE HEIGHT: 24' MAX TO EAVE FOUNDATION WILL BE BACKFILLED AGAINST THE C104 - STAKE & WIRE FENCING PROPOSED MAX. BUILDING HEIGHT: 9' TO EAVE AND 15' TO RIDGE FOUNDATION AND GRADED TO DRAIN AWAY FROM THE BUILDING. NO SOILS SHALL REMAIN EXPOSED AND C233 SILT FENCE OR MULCH BERM UNWORKED FOR MORE THAN 2 DAYS FROM OCT. 1 TO DS APR. 30. ONCE THE DISTURBED LANDSCAPES ARE DOWNSPOUT GRADED, THE GRASS AREAS WILL BE RESEEDED OR 1 PLAN NOTE SODDED. ALL STOCKPILES WILL BE COVERED WITH Job No.: 23-15 PLASTIC OR BURLAP IF LEFT UNWORKED. SPOT ELEVATION E E ELECTRIC W W WATER A1.1 28'-0 1/2" _______2 14'-0 1/4" 14'-0 1/4" A4.0 10 1 2 2 3 4 5 6 7 8 9 10 _______ A4.1 1 3 4 5 7 8 9 H DIM. TO CL OF POST I G (N)GLULAM BEAM ABV. 39'-1 7/8" COVERED PORCH ADDITION VAULTED CEILING 4/12 SLOPE (N) VENTED CRAWLSPACE (N) FOUNDATION, SEE FDN PLAN GUARDRAILS REQUIRED IF DECK SURFACE MORE THAN 30" ABOVE GRADE 2 _______ _______4 A4.1 A4.2 WINDER REQUIRED 12'-9 1/4" TO MEET HEADROOM (E) FOUNDATION, SEE FDN PLAN PER CODE-6'-8" MIN. 13'-9 1/4" 14'-3 1/4" NEW ADDITION 9'-4 3/4" 4'-4 1/2" 2'-7 1/4" 4'-7" 4'-7" 2'-6" 4'-1" F DIM. TO F2 F1 FACE OF 3 DIM. TO CONC. _______ 9'-4 3/4" 4'-4 1/2" 9'-10 3/8" 2'-5 1/2" 6'-8 1/2" A4.2 9'-3 3/8" 9'-6 1/8" FACE OF D2 _______3 CONC. E H A4.0 (E) VENTED CRAWLSPACE W4 F5 F4 F3 3'-0" W4 4'-0" NEW ADDITION 2 G = W5 D13 (N) BATH 4'-1" 3'-4" 5'-10 1/4" (N) BEDROOM 3 3'-1 3/4"D21 DW DN 5'-0" CL. (N) STORAGE 5'-3 1/2" (N) DINING EGRESS REMOVE WINDOW D3 AND FILL IN WITH 11'-4 1/2" 8'-10 1/2" F23 = FRAMING ALIGN NEW FRAMING CONVERT TO EGRESS WINDOW STAIRS: W4 TO CORNER (E) WALL SILL AT +44" A.F.F. MAX. 14RISERS 1 3'-9 3/4" (N) KITCHEN AT 7" 2X4 INTERIOR WALL, TYP. _______ VAULTED CEILING 4/12 SLOPE REMOVE SIDING A4.1 S LINEN S 13'-1 7/8" WH 1/2" AIR GAP FROM CONCRETE 12'-0" ON EXT. WALL 5'-6 1/4" 2'-0" W3 F22 12'-10 1/8" STAIR OPENING 5'-8 5/8" Range D18 D17 D16 3'-6" 8'-0 3/8" FULL HEIGHT WALL F 3'-10" D19 2 D15 STUB FOR _______3 6'-4 7/8" S/CM _______ 7'-9 1/8" STAIR OPENING FUTURE SINK A4.2 (E) WIN. COULD REMAIN A4.2 1 24'-0" 3'-11 5/8" GRINDER (N) MECH. 2'-9 7/8" PUMP STORAGE CL VANITY ABV. _______3 ISLAND 10' X 5' S PANTRY (E) MASTER BEDROOM CLOSET A4.0 DBL OVEN 7'-10 1/8" D 28'-0" Oven E ALIGN 8'-1 1/4" D14 CL TOILET ABV. 3'-6" ALIGN WALL ON CENTER W/POST 28'-0" EXISTING BASEMENT FLUSH INSIDE FACE OF WALL 9'-0 5/8" OF POST 7'-0" (N) SKYLIGHT OVER THE STAIRS TO INSIDE FACE OF BEAM (N)GLULAM 2'-0" C BEAM ABV. (E) DOOR OPENING Refrigerator CL SHOWER DRAIN ABV. ALTER AS NEEDED PER DOOR CL VANITY ABV. 8'-8 1/8" W3 LOCATE WITHIN 3' OF PEAK D9 SELECTION F21 F24 W5 D20 CL WASHER ABV. Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. EGRESS (N) OFFICE (N) BONUS ROOM (N)6X6 POST-BEARING TO CABINETS/COUNTER 4'-0" 3'-3 1/2" 2'-10 1/4" 4'-0 1/8" 2'-4" 2'-6" F6 (N) WALL BELOW TO FTG. 5'-11 3/8" INSTALL PERMANENT W1 9'-2 3/4" DEHUMIDIFIER IN F25 2'-1 1/2" _______1 No. CL TOILET ABV. 3'-4 1/2" BASEMENT, DISCHARGE TO S A4.1 P-TRAP (N) BATHROOM 13'-4" TO CL OF (E) BEAM AND POSTS D8 CL. = B MATCH CL PLUMBING WALL ABV. DIM. TO = D10 CL SHOWER DRAIN ABV. 2'-11" WALL AT +42" A.F.F. D7 FACE OF 15'-6 1/2" W6 _______2 66" VANITY 5'-11 1/4" 4'-0" CONC. A4.2 DN 4'-9" = 5'-4" 15'-11 1/4" TO STAIR OPENING CLOSET 3'-10 7/8" 1'-2" MIRROR DIM. ON FIREPLACE CENTER 7'-9 1/8" = CONFIRM RO WITH POCKET DOOR SPECS (2)2X FIREPLACE D11 3 1/2" D 3'-3 1/2" SHOWER/TOILET A MATCH (N) GREAT ROOM = FLAT CEILING AT 7' 10-3/4" EXISTING RESIDENCE F20 4'-0" 2'-0" MIRROR DIM. ON FIREPLACE CENTER REBUILD FP AT INTERIOR (N)6x6 POST-BEARING TO METAL RAILING 3'-1" 3'-8 1/4"S/CM SHOWER 4'-3 1/2" F7 AT +36" A.F.F. 4' W X 3' D = Issue Date TO CENTER BEAM BELOW C ON BEAMS ABV. AND STAIR D4 D5 S ADD 2' X 2' SKYLIGHT ABOVE F8 7'-6" 9'-0 1/2" 30'-1 3/8" W1 (N) GLULAM BEAM ABV. 42" VANITY 4'-9 7/8" (N) BEDROOM 2 F19 Author F9 4'-2 1/2"4'-2 1/2" 3'-4 1/2"(N) BATH W2 1'-0" Drawn by: _______1 D12 5'-0" A4.0 BENCH/CUBBIES/CABS 9'-7 5/8" B 2 BASEMENT LEVEL 7'-6" W3 F18 1/4" = 1'-0" 6'-2 7/8" A4.0 1'-4 3/8"1'-4 3/8" CLOSET F10 F11 F12 1'-3 1/2" 4'-5 1/2"2'-10" 2'-2" 2'-4 1/2" 6'-7 7/8" 6'-7 7/8" 4'-9 7/8" REMODEL/ADDITION FLOOR PLANS 3'-1 3/8" EGRESS Scale: FLOOR PLAN NOTES D1 As indicated SMOKE ALARMS AND HEAT DETECTION A FRAMING: 2X6 EXTERIOR WALLS REQUIRED LOCATIONS R314.3: FRAMING - DOOR SCH. 1'-6" 3'-0" 7'-6" SMOKE ALARMS/CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN: 2X4/6's AT INTERIOR WALLS UNLESS NOTED OTHERWISE 1. IN EACH SLEEPING ROOM OR SLEEPING LOFT NO. DOOR SIZE HEAD HEIGHT COMMENTS F13 F14 F15 F16 F17 FILL IN 2X4 FRAMING 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE BASEMENT FF AT ALL MODIFIED SEE STRUCTURAL NOTES FOR STUD SCHEDULE. VICINITY OF THE BEDROOMS. D13 2'-6" 6'-8" 6'-8" COVERED WINDOW OPENINGS 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING CONCEALED SPACES SHALL BE FIRESTOPPED IN BOTH DIRECTIONS AT BASEMENTS AND HABITABLE ATTICS. D14 2'-10" 6'-8" 6'-8" NEW ADDITION PORCH 10" ON CENTER AND AT FLOORS. TYPICAL. 4. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET FROM D15 2'-6" 6'-8" 6'-8" THE DOOR OR OPENING OF A BATHROOM. D16 2'-4" 6'-8" 6'-8" ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH D17 1'-8" 6'-8" 6'-8" DN AA HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. THE LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER D18 2'-6" 6'-8" 6'-8" MINIMUM CLEAR OPENING HEIGHT DIMENSION SHALL BE 24". MINIMUM THAN 24". CLEAR OPENING WIDTH DIMENSION SHALL BE 20". SILL HEIGHT SHALL D19 2'-6" 6'-8" 6'-8" NOT BE MORE THAN 44" ABOVE THE FLOOR. ALTERATIONS, REPAIRS AND ADDITIONS R314.2.2 WHERE ALTERATIONS, D20 2'-6" 6'-8" 6'-8" REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHERE ONE OR D21 5'-0" 6'-8" 6'-8" _______1 SHOWER COMPARTMENTS AND WALLS AROUND BATHTUBS WITH MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DEMO 2'-6" 6'-8" 6'-8" A4.0 SHOWERS SHALL BE FINISHED WITH A SMOOTH NON-ABSORBANT DWELLINGS, OR WHERE AN ACCESSORY DWELLING UNIT IS CREATED DEMO 2'-6" 6'-8" 6'-8" SURFACE TO NOT LESS THAN 72" ABOVE THE FLOOR (IRC R307.2). WITHIN AN EXISTING DWELLING UNIT, EACH DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS AS REQUIRED FOR NEW DWELLINGS. MAIN LEVEL 2 6 ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN D1 3'-0" 6'-8" 6'-8" 1 MAIN LEVEL OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM OF 3/4" D2 6'-0" 6'-8" 6'-8" 1/4" = 1'-0" ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER A4.0 D3 6'-0" 6'-8" 6'-8" DOOR AND TRANSFER GRILLE ABOVE DOOR. HEAT DETECTION INTERCONNECTION R314.4.1 HEAT DETECTORS AND HEAT ALARMS SHALL BE CONNECTED TO AN ALARM OR A SMOKE ALARM D4 2'-6" 6'-8" 6'-8" PROVIDE WEATHER RESISTANT FIBER CEMENT WALLBOARD UNDER TUB THAT IS INSTALLED IN THE DWELLING. ALARMS THAT ARE INSTALLED FOR D5 2'-8" 6'-8" 6'-8" AND SHOWER ENCLOSURE MATERIALS TO A HEIGHT OF 70" MINIMUM THIS PURPOSE SHALL BE LOCATED IN A HALLWAY, ROOM, OR OTHER D6 2'-6" 6'-8" 6'-8" ABOVE THE DRAIN INLET. LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION. D7 2'-6" 6'-8" 6'-8" FLOOR PLAN KEY NOTES ARLINGTON, WA D8 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN COMBINATION ALARMS R314.5 COMBINATION SMOKE AND CARBON OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM ? 3/4" MONOXIDE ALARMS MAY BE USED IN PLACE OF SMOKE ALARMS. D9 6'-0" 6'-8" 6'-8" NO. DESCRIPTION ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D10 5'-0" 6'-8" 6'-8" 1 EXISTING SEWER ~5' ABOVE FFE DOOR AND TRANSFER GRILLE ABOVE DOOR. POWER SOURCE R314.6 SMOKE ALARMS, HEAT ALARMS, AND HEAT D11 2'-6" 6'-8" 6'-8" 2 EXISTING ELECTRICAL PANEL-150 AMP, UPGRADE TO 200 AMP DETECTORS SHALL RECEIVE PRIMARY POWER FROM THE BUILDING D12 5'-0" 6'-8" 6'-8" 1. A CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH WIRING AND, WHEN POWER IS INTERRUPTED, SHALL RECEIVE POWER SEPARATE SLEEPING AREA IN IMMEDIATE VICINITY OF BEDROOMS D22 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ADDITION FROM A BATTERY. AND ON EACH LEVEL PER 2015 IRC R315. DEMO 2'-0" 6'-8" 6'-8" 2. A SMOKE DETECTOR SHALL BE INSTALLED IN EACH HABITABLE ROOM. INTERCONNECTIVITY R314.4 WHERE MORE THAN ONE SMOKE ALARM IS DEMO 2'-4" 6'-8" 6'-8" 3. A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH REQUIRED TO BE INSTALLED, THE ALARM DEVICES SHALL BE DEMO 5'-0" 6'-8" 6'-8" FLOOR. INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE DEMO 2'-6" 6'-8" 6'-8" 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING DEMO 2'-6" 6'-8" 6'-8" LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL NOT BE THAN 24". REQUIRED WHERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL DEMO 2'-0" 6'-8" 6'-8" 5. SMOKE DETECTORS SHALL BE 110V HARDWIRED, INTERCONNECTED, ALARMS SOUND UPON ACTIVATION OF ONE ALARM. Job No.: 23-15 WITH BATTERY BACKUP, PER 2015 IRC R314. WHERE AN ACCESSORY DWELLING UNIT IS CREATED WITHIN AN EXISTING NOTE: A SPRINKLER SYSTEM IS NOT REQUIRED FOR THIS RESIDENCE. DWELLING UNIT ALL REQUIRED SMOKE ALARMS, IN THE ACCESSORY DWELLING UNIT AND THE PRIMARY DWELLING UNIT, SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL ALARMS IN BOTH THE PRIMARY DWELLING UNIT A2.0 AND THE ACCESSORY DWELLING UNIT DW DN (N) KITCHEN (N) DINING 1 Range Oven (E) MASTER BEDROOM 3 S/CM (N) BATH Refrigerator (N) BEDROOM 3 (N) STORAGE WH (N) GREAT ROOM Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. 4 ALL LIGHTING AND SWITCH LOCATIONS TO BE COORDINATED BETWEEN OWNER, (N) BATHROOM No. GENERAL CONTRACTOR AND ELECTRICIAN, 6 DESIGNER TO BE CONSULTED AS NEEDED EXISTING FURNACE SHOWER/TOILET REMOVE (N) MECH. 2 5 (N) OFFICE (N) BONUS ROOM Issue Date ALL LIGHTING AND SWITCH LOCATIONS (N) BATH TO BE COORDINATED BETWEEN OWNER, GENERAL CONTRACTOR AND ELECTRICIAN, 2 DESIGNER TO BE CONSULTED AS NEEDED (N) BEDROOM 2 Drawn by:Author ELECTRICAL & MECHANICAL 2 BASEMENT MEP A4.0 1/4" = 1'-0" Scale: As indicated DN 1 MAIN LEVEL MEP 1/4" = 1'-0" A4.0 VENTILATION REQUIREMENTS HEATING REQUIREMENTS SPRINKLERS GENERAL ELECTRICAL NOTES MEP KEY NOTES EQUIPMENT BY OTHERS BUILDING DESIGN HEAT LOAD 27,240 BTU/HR NOT APPLICABLE NO. DESCRIPTION IRC M1505 EQUATION 15-1: MAXIMUM HEAT EQUIPMENT OUTPUT 34,050 THIS ELECTRICAL PLAN IS THE ARCHITECT'S SUGGESTED LAYOUT. THE ELECTRICAL CONTRACT 1 VENT HOOD MIN. 100CFM WHOLE HOUSE CONTINUOUS RATE CALCULATION: BTU/HR IS ON A DESIGN-BUILD BASIS. ELECTRICAL CONTRACTOR'S DESIGN SHALL BE APPROVED BY 2 BATHROOM EXHAUST FAN MIN. 50CFM (0.01 X 2213 SQFT) + (7.5 X (3 BEDROOMS+1)) = 52 CFM CONTINUOUS VENTILATION THE OWNER AND SHALL CONFORM TO THE APPLICABLE ELECTRICAL CODE REGARDLESS OF DUCTED HEATPUMP SYSTEM WHAT IS SHOWN IN THIS DRAWING. 3 PANASONIC WHISPER 50/80/110 ON TIMER WHOLE HOUSE INTERMITTENT VENTILATION CALCULATION: BASED ON 12.4 BTU PER SF OF SPACE 4 RHEEM PROTERRA-INTAKE AND EXHAUST TO EXTERIOR ARLINGTON, WA 52CFM X 2 (FACTOR BASED ON 50% RUN TIME)= 102 CFM 50% INTERMITTENT VENTILATION WELL EQUIPMENT ALL SWITCHES, OUTLETSAND ENVIRONMENTAL CONTROLS SHALL BE MOUNTED NOT LESS 5 MITSUBISHI HYPERHEAT HEAT PUMP 309 S DUNHAM AVE THAN 15"NOR MORE THAN 72" ABOVE THE FINISHED FLOOR AND SHALL BE ALIGNED 6 MITSUBISHI AIR HANDLER IN MECH. WHOLE HOUSE VENTILATION PROVIDED BY WHOLE HOUSE FAN VERTICALLY, U.N.O. NOT APPLICABLE ON A TIMER SET TO CONTINUOUS WITH LOCK OUT OR 50% IF INTERMITTENT OPERATION PREFERRED: APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE SECURELY FASTENED IN PLACE. EQUIPMENT = PANASONIC WHISPER FV-0511VK3 50/80/110 CFM WATER HEATERS SHALL BE ANCHORED OR STRAPPED AT POINTS WITHIN THE UPPER 1/3 AND 309 S DUNHAM AVE ADDITION BATHROOM VENTILATION: WATER STORAGE LOWER 1/3 TO RESIST EARTHQUAKE. VENTILATION WHICH WILL PROVIDE AT LEAST 50 CFM VENTILATION LIGHT FIXTURES THAT SERVE TO ILLUMINATE INTERIOR STAIRS SHALL BE LOCATED IN THE CITY WATER IMMEDIATE VICINITY OF EACH STAIR LANDING AND SHALL PROVIDE A MIN. LIGHTING LEVEL OF KITCHEN VENTILATION: 1 FOOT-CANDLE MEASURED AT CENTER OF TREADS AND LANDINGS PER IRC R303.6. EQUIPMENT WILL PROVIDE AT LEAST 100CFM VIA EXTERIOR VENTED HOOD OVER STOVE Job No.: 23-15 A2.1 4" TIGHTLINE TO DRYWELL _______2 1 3 4 5 7 8 9 A4.0 4" / 12" 4" / 12" 2'-0" I DO NOT LOCATE PLUMBING MATCH EXISTING OVERHANG THIS SIDE VENTS IN THE SOLAR READY ZONE 1 _______2 SOLAR READY ZONE 372SF _______4 A4.1 A4.2 ADJUST OVERHANG SO FASCIA IS ABOVE EXISTING ROOF OR TO MATCH EXISTING 15'-9 1/4" RIDGE VENT H G RJ 3 RJ 5'-1 7/8" 2 DS RJ F 3 _______ RJ A4.2 _______3 A4.0 RJ E Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. No. RJ RJ 5 5 RIDGE VENT 2 RIDGE VENT RJ 1 _______ A4.1 DS DS 4" / 12" ROOF PLAN KEY NOTES _______2 4 ROOF PLAN LEGEND A4.2 4" / 12" NO. DESCRIPTION RIDGE VENT RJ 1 SOLAR READY ZONE Issue Date GUTTER (DOUBLE LINE) 2 DOWNSPOUT TO TIGHTLINE TO DRYWELL D 3 30-YEAR ASPHALT ROOF 4" / 12" RIDGE VENT DS DOWNSPOUT LOCATION 4 DOWNSPOUT TO TIGHTLINE TO RAIN GARDEN OR SWALE 5 OVERFRAME OVER EXISTING 4" / 12" SOLAR READY AREA ROOF PER STRUC. C ROOF PLAN OVERFRAME OVER EXISTING ROOF PER STRUC. Drawn by:Author BUILDING OUTLINE RJ ROOF PLAN NOTES RJ RJ DS = DOWNSPOUT (4" SOLID PIPE TIGHTLINED INDEPENDENT OF INSTALL MINIMUM ONE FALL-ARREST BRACKET Scale: FOOTING DRAIN) TO BMP AS NOTED ON SITE PLAN. CENTRALLY LOCATED B As indicated ROOF SYSTEM PER ENGINEER PER IRC 324.6.1 - MIN. (3) 36" PATH AND 18" PATH AT • SHALL HAVE DESIGN DETAILS AND DRAWINGS ON SITE FOR RIDGE 5 FRAMING INSPECTION • SHALL BE INSTALLED AND BRACED PER MANUF. SPECS. 4 RJ RJ RJ A PER IRC AT103.3 - SOLAR READY ZONE MIN. 300 SF (CALC PROVIDED): DS RIDGE VENT RJ 5 ON HOUSE 372SF PROVIDED MATCH EXISTING ROOF 4" / 12" 4" / 12" 10 ATTIC VENTILATION CALCULATIONS: RJ 4 RIDGE VENT = 21.5 SQ. IN. PER LINEAR FT. DS ROOF JACK =38 SQ. IN. EA. BIRD BLOCKING= 3.5 SQ. IN PER LINEAR FT. ADD SOFFIT VENTING AA OR LOW ROOF JACKS AREA 1-ATTIC AREA OVER CONDITIONED= 1356SF TO EXISTING ROOF AREA 1356SF/150 = 9.04 SF REQUIRED MATCH EXISTING ROOF 34LF RIDGE VENT = 34 X 21.5 = 731SQ. IN/144= 5.07 SQ. FT. 16 EA LOW ROOF JACKS = 16 X 38= 608SQ. IN/144= 4.22 SQ. FT. 1 _______ TOTAL PROVIDED = 9.29 SQ. FT. A4.0 AREA 2-VENTED RAFTERS OVER PORCH= 401 SF 2 DUTCH HIP ROOF 401SF/150 = 2.67 SF REQUIRED 6 4" TIGHTLINE TO RAIN GARDEN OR SWALE SEE ELEVATIONS TO MATCH NORTH FACING EXISTING AND 3D FOR ADDITIONAL ROOF STYLE 12LF RIDGE VENT = 12 X 21.5 = 258SQ. IN/144= 1.79 SQ. FT. 28LF BIRD BLOCKING = 28 X 3.5 = 98SQ. IN/144= .68 SQ. FT. MATCH EXISTING ROOFVISUAL INFO ARLINGTON, WA 2 EA LOW ROOF JACKS = 2 X 38= 76SQ. IN/144= .52 SQ. FT. 4" TIGHTLINE TO RAIN GARDEN OR SWALE 309 S DUNHAM AVE TOTAL PROVIDED = 2.99 SQ. FT. 1 WORK - ROOF 1/4" = 1'-0" A4.0 309 S DUNHAM AVE ADDITION Job No.: 23-15 A2.2 1 2 3 4 5 7 8 9 1 2 3 4 5 7 8 9 DEMO EXISTING DECK EXISTING ROOF OVERHANG AND ROOF COVERING TO BE CUT BACK FLUSH TO GRID F SEE DETAIL 1/A4.2 EXISTING WALL COULD REMAIN IN PLACE AND FILL IN DOOR OR REFRAME PER NEW FLOOR PLAN 2'-0" F F 2'-0" E E EXISTING ROOF OVERHANG TO BE CUT BACK FLUSH TO GRID E SEE DETAIL 1/A4.2 1'-6 1/2" WALL TO REMAIN IN PLACE AS BEARING WALL. WILL BE MODIFIED AT ENDS, (E) BEDROOM Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. TEMP 2X4 WALL TO SUPPORT SEE FRAMING PLANS FOR DIMENSIONS (E) KITCHEN ROOF DURING WALL REMOVAL -COULD REFRAME WALL IF DESIRED AND HEADER REPLACEMENT No. BUT PROVIDE TEMPORARY SUPPORT WALL (E) MECHANICAL PRIOR TO REMOVAL OR MODIFICATION REMOVE EXISTING SKYLIGHT STAIR (E) LAUNDRY LEAVE IN PLACE TEMP. REMOVE ON NEW WALL AT BED TO BATH IN PLACE LEAVE IN PLACE TEMP. (E) LIVING ROOM DEMO WALL TO HERE AND REFRAME? LEAVE WALL IN PLACE AS TEMPORARY (E) BATH ROOF SUPPORT UNTIL NEW BEAMS INSTALLED PER STRUC. CONSIDER REFRAME D D DOOR OPENING Issue Date DEMO EXISTING WALLS, NON-BEARING LEAVE IN PLACE TEMP., C REMOVE ONCE NEW WALL AT C LAUNDRY/BATHROOM IN PLACE USE TEMP WALLS AS (E) BONUS ROOM NEEDED FOR HEADER REPLACEMENTS PER Drawn by:Author LEAVE IN PLACE TEMP., REMOVE ONCE NEW WALL BEST PRACTICES DEMOLITION PLAN (E) BEDROOM BETWEEN BED AND BATH IN PLACE FILL IN FRAMING REMOVE HEADER AND WALL (E) DINING (E) BEDROOM 10'-1 5/8" B B Scale: 1/4" = 1'-0" 6 6 A A USE TEMP WALLS AS 10 10 NEEDED FOR HEADER DEMO CONCRETE STAIRS REPLACEMENTS PER SAW CUT CONCRETE AS BEST PRACTICES NECESSARY TO ENSURE CLEAN REMOVAL AA EXISTING ROOF OVERHANG AA TO BE CUT BACK FLUSH TO GRID A 2 BASEMENT DEMOLITION PLAN 1 MAIN LEVEL DEMOLITION PLAN 1/4" = 1'-0" 1/4" = 1'-0" A4.0 A4.0 ARLINGTON, WA 309 S DUNHAM AVE 309 S DUNHAM AVE ADDITION Job No.: 23-15 A3.0 1 2 3 4 5 7 8 9 2 3/4" 2 3/4" I SONOTUBE O/24" BIG FOOT BF24 FOOTING VERIFY WITH STRUC. 28'-0 1/2" 14'-0 1/4" 14'-0 1/4" H 3'-0" G DOWEL AND EPOXY PER STRUC, 11'-4 1/2" 6" STEM WALL ~2' TALL KITCHEN SINK WASTE LINE FOOTING AND NOT DRIVING DIMENSION 15'-0" REBAR PER STRUC. PROPOSED ADDITION MAY NEED KNOCK OUT DRIVING DIMENSION 12'-0" FOR PLUMBING WASTE LINE VENTED CRAWLSPACE FROM KITCHEN TO BASEMENT DOWEL AND EPOXY INSTALL 10 MIL VAPOR PER STRUC. BARRIER OVER GROUND F EXISTING FULL HEIGHT BASEMENT FOUNDATION WALL (E) STEM WALLS 4'-0" (N) STAIR OPENING E FOUNDATION VENT, 5 EA LOCATE WITHIN 3' OF CORNERS Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. No. RECOMMEND INSTALLATION OF INTERIOR FOOTING DRAIN SYSTEM, BY OTHERS TIE INTO SUMP PUMP DISCHARGE SUMP INTO TIGHTLINE TO DRYWELL OR RAIN GARDENS WH 12'-10 1/8" (N) STAIR OPENING GRINDER PUMP LOC. PLUMBER TO VERIFY POSSIBLE SUMP LOCATION CL VANITY ABV. Issue Date D CL TOILET ABV. 7'-9 1/8" (N) STAIR OPENING 7'-0" EXISTING BASEMENT C CL VANITY ABV. CL SHOWER DRAIN ABV. Drawn by:Author 8'-8 1/8" CL WASHER ABV. (N) BONUS ROOM CL TOILET ABV. 3'-4 1/2" FOUNDATION & FRAMING PLAN FOUNDATION PLAN NOTES B Scale: As indicated CL PLUMBING WALL ABV. CRAWLSPACE VENTILATION CALCULATIONS: CL SHOWER DRAIN ABV. 2'-11" 15'-6 1/2" FOUNDATION VENT = 72.5 SQ. IN. PER EA. 16X8 UNIT AREA 1-NEW CRAWLSPACE= 347SF 1'-2" 347SF/150 = 2.31 SF OR 332 SQ. IN. REQUIRED A 5 FOUNDATION VENTS = 5 X 72.5 = 362.5 SQ. IN PROVIDED DROP PLUMBING WASTE FROM ABOVE TO NEW BASEMENT WALL, 10 SAW CUT FROM THIS LOCATION TO GRINDER PUMP LOC. PER PLUMBER PLUMBING WALL AA (VERIFY FIXTURE LOCATION WITH CABINETRY) 1 PLAN NOTE 1 FOUNDATION PLAN 6 SPOT ELEVATION 1/4" = 1'-0" A4.0 ARLINGTON, WA 309 S DUNHAM AVE E E ELECTRIC W W WATER 309 S DUNHAM AVE ADDITION DOWNSPOUT LOCATION DS Job No.: 23-15 A3.1 2 _______ 2 _______ A4.1 A4.1 PROPOSED ADDITION 3 NEW ROOF BEYOND ELEVATION KEY NOTES DUTCH HIP TO MATCH NORTH ELEVATION ROOF STYLE 8 TOP OF RIDGE 191'-10" TOP OF RIDGE 191'-10" NO. DESCRIPTION 1 (N) ASPHALT ROOF 2 WRAP POSTS IN PWW 2 OR 3 EQUAL RISERS IF 3 OR MORE HANDRAIL 3 HARDIE LAP SIDING-8" REVEAL, VERIFY WITH OWNER REQUIRED PER IRC 4" / 12" 1 4 TREX DECK FASCIA 3 3 _______ _______ 5 1X6 PWW TRIM OR HARDIE TRIM A4.2 4" / 12" A4.2 4" / 12" 6 (N) 5" GUTTER 7 TREX DECKING OR EQUIV. TOP PLATE 186'-0 3/4" TOP PLATE 186'-0 3/4" 8 1X10 PWW TRIM OR HARDIE TRIM F14 D1 2 F22 3 F1 F2 F3 F4 F5 F10 F11 F12 F15 F16 F17 D2 2 F13 7'-10 3/4" 7 4 DOOR FRAMING SCHEDULE MAIN LEVEL 178'-2" MAIN LEVEL 178'-2" NO. DOOR SIZE HEAD HEIGHT COMMENTS GRADE 176'-10" GRADE 176'-10" BASEMENT FF D13 2'-6" 6'-8" 6'-8" D14 2'-10" 6'-8" 6'-8" D15 2'-6" 6'-8" 6'-8" D16 2'-4" 6'-8" 6'-8" D17 1'-8" 6'-8" 6'-8" D18 2'-6" 6'-8" 6'-8" D19 2'-6" 6'-8" 6'-8" D20 2'-6" 6'-8" 6'-8" D21 5'-0" 6'-8" 6'-8" BASEMENT FF 170'-0" BASEMENT FF 170'-0" DEMO 2'-6" 6'-8" 6'-8" DEMO 2'-6" 6'-8" 6'-8" MAIN LEVEL 2 EAST ELEVATION 1 WEST ELEVATION D1 3'-0" 6'-8" 6'-8" D2 6'-0" 6'-8" 6'-8" 1/4" = 1'-0" 1/4" = 1'-0" A2.0 A2.0 D3 6'-0" 6'-8" 6'-8" D4 2'-6" 6'-8" 6'-8" D5 2'-8" 6'-8" 6'-8" D6 2'-6" 6'-8" 6'-8" D7 2'-6" 6'-8" 6'-8" D8 2'-6" 6'-8" 6'-8" D9 6'-0" 6'-8" 6'-8" D10 5'-0" 6'-8" 6'-8" PROPOSED ADDITION EXISTING RESIDENCE PROPOSED PORCH ADDITION D11 2'-6" 6'-8" 6'-8" D12 5'-0" 6'-8" 6'-8" D22 2'-6" 6'-8" 6'-8" Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. 4 DEMO 2'-0" 6'-8" 6'-8" _______ A4.2 OVERFRAME NEW ROOF DEMO 2'-4" 6'-8" 6'-8" SIDING TO MATCH ON EXISTING DEMO 5'-0" 6'-8" 6'-8" No. AND NEW ADDITION DEMO 2'-6" 6'-8" 6'-8" REPLACE FASCIA AS NEEDED DEMO 2'-6" 6'-8" 6'-8" DEMO 2'-0" 6'-8" 6'-8" TOP OF RIDGE 191'-10" OVERFRAME NEW ROOF 1 4" / 12" 4" / 12" FRAMING - WINDOW SCH. 6 MARK SIZE (W x H) HEAD HEIGHT REMARKS F1 2'-6"x4'-6" 6'-8" 3" / 12" TOP PLATE 186'-0 3/4" F2 2'-6"x4'-6" 6'-8" F3 2'-0"x3'-6" 6'-6" VENT-FIXED-V ENT Issue Date 15'-0" _______2 F4 4'-0"x3'-6" 6'-6" VENT-FIXED-V A4.2 ENT 2 5 F6 3 F7 F8 F9 F5 2'-0"x3'-6" 6'-6" VENT-FIXED-V ENT 2 OR 3 EQUAL RISERS 7'-10 3/4" F6 2'-6"x4'-6" 7'-0" 7 IF 3 OR MORE HANDRAIL F7 2'-6"x4'-6" 7'-0" VENT-FIXED-V ELEVATIONS 4 4 REQUIRED PER IRC ENT Author Drawn by: F8 2'-6"x4'-6" 7'-0" VENT-FIXED-V ENT MAIN LEVEL 178'-2" F9 2'-6"x4'-6" 7'-0" VENT-FIXED-V ENT GRADE 176'-10" F10 2'-6"x4'-6" 7'-0" VENT-FIXED-V ENT F11 2'-6"x4'-6" 7'-0" VENT-FIXED-V ENT Scale: F12 2'-6"x4'-6" 7'-0" VENT-FIXED-V 1/4" = 1'-0" ENT F13 1'-6"x5'-0" 6'-8" F14 3'-0"x1'-6" 7'-0" VENT-FIXED-V ENT F15 2'-6"x4'-6" 7'-0" VENT-FIXED-V BASEMENT FF 170'-0" ENT F16 2'-6"x4'-6" 7'-0" VENT-FIXED-V ENT F17 2'-6"x4'-6" 7'-0" EGRESS F18 2'-6"x4'-6" 7'-0" FIXED-FIXED 3 NORTH ELEVATION F19 2'-6"x4'-6" 7'-0" FIXED-FIXED A2.0 1/4" = 1'-0" F20 2'-0"x3'-6" 7'-0" F21 2'-6"x4'-6" 7'-0" EGRESS F22 5'-0"x3'-6" 6'-11 1/2" EGRESS F23 3'-0"x3'-0" 6'-8" EGRESS F24 3'-0"x1'-6" 7'-1" F25 3'-0"x1'-6" 7'-1" ARLINGTON, WA 309 S DUNHAM AVE 309 S DUNHAM AVE ADDITION Job No.: 23-15 A4.0 ELEVATION KEY NOTES NO. DESCRIPTION 1 (N) ASPHALT ROOF 4 _______ A4.2 2 WRAP POSTS IN PWW PROPOSED PORCH ADDITION PROPOSED ADDITION 3 HARDIE LAP SIDING-8" REVEAL, VERIFY WITH OWNER 4 TREX DECK FASCIA 5 1X6 PWW TRIM OR HARDIE TRIM 6 (N) 5" GUTTER TOP OF RIDGE 191'-10" 7 TREX DECKING OR EQUIV. 8 1X10 PWW TRIM OR HARDIE TRIM 3" / 12" 4" / 12" 3" / 12" TOP PLATE 186'-0 3/4" 2 _______ DOOR FRAMING SCHEDULE F20 A4.2 F18 F19 F21 NO. DOOR SIZE HEAD HEIGHT COMMENTS D3 BASEMENT FF 7'-10 3/4" D13 2'-6" 6'-8" 6'-8" D14 2'-10" 6'-8" 6'-8" D15 2'-6" 6'-8" 6'-8" D16 2'-4" 6'-8" 6'-8" MAIN LEVEL 178'-2" D17 1'-8" 6'-8" 6'-8" D18 2'-6" 6'-8" 6'-8" GRADE 176'-10" D19 2'-6" 6'-8" 6'-8" D20 2'-6" 6'-8" 6'-8" D21 5'-0" 6'-8" 6'-8" DEMO 2'-6" 6'-8" 6'-8" DEMO 2'-6" 6'-8" 6'-8" MAIN LEVEL D1 3'-0" 6'-8" 6'-8" D2 6'-0" 6'-8" 6'-8" D3 6'-0" 6'-8" 6'-8" BASEMENT FF 170'-0" D4 2'-6" 6'-8" 6'-8" D5 2'-8" 6'-8" 6'-8" D6 2'-6" 6'-8" 6'-8" D7 2'-6" 6'-8" 6'-8" D8 2'-6" 6'-8" 6'-8" D9 6'-0" 6'-8" 6'-8" 1 SOUTH ELEVATION D10 5'-0" 6'-8" 6'-8" A2.0 1/4" = 1'-0" D11 2'-6" 6'-8" 6'-8" D12 5'-0" 6'-8" 6'-8" D22 2'-6" 6'-8" 6'-8" Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. DEMO 2'-0" 6'-8" 6'-8" DEMO 2'-4" 6'-8" 6'-8" DEMO 5'-0" 6'-8" 6'-8" No. DEMO 2'-6" 6'-8" 6'-8" R2-VENTED ROOF OVER UNCONDITIONED: W4-2X6 EXTERIOR WALL R-26: DEMO 2'-6" 6'-8" 6'-8" • 30-YEAR ASPHALT ROOFING • 1/2 GYPSUM DEMO 2'-0" 6'-8" 6'-8" • WRB WATER-30# TAR PAPER • 2X6" DF • 1/2" PLYWOOD SHEATHING • BLOWN IN CELLULOSE OR BATT R-20 • 2X OR LVL RAFTERS PER STRUC. • 1 1/2" ZIP R-SHEATHING R-6 • VENTED RIDGE • SIDING PER OWNER SPEC. • SOFFIT-T AND G PINE OR EQUIV. • EXTERIOR GRADE PAINT OR STAIN FRAMING - WINDOW SCH. MARK SIZE (W x H) HEAD HEIGHT REMARKS I 4 H G F E (N) GLULAM HEADER D C B A AA _______ PER STRUC. F1 2'-6"x4'-6" 6'-8" A4.2 F2 2'-6"x4'-6" 6'-8" INSTALL ROOF JACKS AT F3 2'-0"x3'-6" 6'-6" VENT-FIXED-V OVERFRAMED AREAS CUT VENT HOLES 6" X 6" BETWEEN (E) ATTIC ENT Issue Date AND OVERFRAMED AREAS (N) GLULAM PER F4 4'-0"x3'-6" 6'-6" VENT-FIXED-V STRUC. EXTEND SLOPE OF (E) ROOF TO NEW RIDGE TOP OF RIDGE 191'-10" ENT F5 2'-0"x3'-6" 6'-6" VENT-FIXED-V ENT 2X RAFTERS PER STRUC. F6 2'-6"x4'-6" 7'-0" 4" / 12" F7 2'-6"x4'-6" 7'-0" VENT-FIXED-V ENT Author Drawn by: F8 2'-6"x4'-6" 7'-0" VENT-FIXED-V VAULTED CEILING ENT (E) ATTIC-2X4 RAFTERS, 2X6 CEILING JOISTS F9 2'-6"x4'-6" 7'-0" VENT-FIXED-V TOP PLATE 186'-0 3/4" ENT ELEVATIONS AND SECTIONS W4 F10 2'-6"x4'-6" 7'-0" VENT-FIXED-V ENT 2 _______ 15'-0" F11 2'-6"x4'-6" 7'-0" VENT-FIXED-V (N) COVERED PORCH A4.2 (N) GREAT ROOM ENT Scale: (N) KITCHEN (E) (5) 2X8 BUILT F12 2'-6"x4'-6" 7'-0" VENT-FIXED-V 1/4" = 1'-0" (N) COVERED PORCH UP BEAM ENT 7'-10 3/4" F13 1'-6"x5'-0" 6'-8" 6'-11 1/4" F14 3'-0"x1'-6" 7'-0" VENT-FIXED-V DECK FRAMING PER STRUC. ENT F15 2'-6"x4'-6" 7'-0" VENT-FIXED-V _______1 MAIN LEVEL 178'-2" ENT A4.2 F16 2'-6"x4'-6" 7'-0" VENT-FIXED-V GRADE 176'-10" ENT F17 2'-6"x4'-6" 7'-0" EGRESS (N) VENTED CRAWLSPACE F18 2'-6"x4'-6" 7'-0" FIXED-FIXED F19 2'-6"x4'-6" 7'-0" FIXED-FIXED F20 2'-0"x3'-6" 7'-0" W5 W5 W1 F21 2'-6"x4'-6" 7'-0" EGRESS W6 (N) BEDROOM 3 (N) MECH. (N) OFFICE F22 5'-0"x3'-6" 6'-11 1/2" EGRESS F23 3'-0"x3'-0" 6'-8" EGRESS F24 3'-0"x1'-6" 7'-1" F25 3'-0"x1'-6" 7'-1" BASEMENT FF 170'-0" (N) FOOTING PER STRUC. W5-2x4 BASEMENT WALL: FL2-FLOOR OVER CRAWLSPACE: • NO WATERPROOF COATING ON CONCRETE FL3-FLOOR OVER CONDITIONED: ARLINGTON, WA • FINISH FLOORING PER OWNER SPEC. • 2" RIGID EPS FOAM • FINISH FLOORING PER OWNER SPEC. 309 S DUNHAM AVE • 3/4 T&G FLOOR SHEATHING • 2X4 STUD WALL W/ MINERAL WOOL INSUL. R-15 • 3/4 T&G FLOOR SHEATHING • 11 7/8 TJI • 1/2" GYPSUM • 2X8 ROUGH SAWN FLOOR JOISTS • BATT INSULATION R-30 • NON-PVA WALL PRIMER • 5/8 GYPSUM • VENTED CRAWLSPACE • LOW OR NO VOC LATEX PAINT • 10MIL VAPOR BARRIER OVER GROUND 309 S DUNHAM AVE ADDITION 2 Section 1 1/4" = 1'-0" A2.0 Job No.: 23-15 A4.1 3 4 5 7 _______ 8 A4.2 E 2 4 _______ A4.1 9 8 7 5 3 2 1 MAIN LEVEL 178'-2" GRADE 176'-10" RAFTERS 2" ABOVE BEAM TO ALLOW FOR VENTING 2" 191'-10" TOP OF RIDGE 8'-2" 2X6 WALL OVER BEAM TO UNDERSIDE OF (N) ROOF EXISTING WALL PLATE TO REMAIN CUT VENT _______3 OR BE REMOVED, FIELD FIT OPENINGS IN EXISTING A4.2 OPTIONAL T AND G PINE SOFFIT SHEATHING BETWEEN ATTIC WALL OVER BEAM TO UNDERSIDE OF NEW ROOF BASEMENT FF 170'-0" OVERFRAMED ATTIC AND OVER FRAMED AREAS TO ALLOW 2X6 WALL OVER BEAM TO UNDERSIDE OF (N) ROOF AIR FLOW TO ROOF JACKS AND RIDGE 186'-0 3/4" TOP PLATE R-21 BATT INSULATION CUT BACK (E) RAFTER ENDS FLUSH TO NEW WALL 13'-6" FFE TO TOP OF BEAM ATTIC (E) 2X4 ROOF RAFTER 7'-10 3/4" TOP PLATE 186'-0 3/4" 2 Stair Section 2 1/4" = 1'-0" DIMENSION IS TO TOP 5/8 GYP., TYP. CEILINGS A2.0 OF FLOOR SHEATHING AT GLULAM BEAM PER STRUC. 178'-2" MAIN LEVEL INTERIOR 176'-10" GRADE (N) GLULAM BEAM HEADER PER STRUC. E D 2X PT DECKING PER STRUC. TREX DECKING OR EQUIV. TOP PLATE 186'-0 3/4" Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. 2 _______ 4 Section 2 No. A4.2 1/4" = 1'-0" OPEN TO ABOVE A2.0 PROPOSED KITCHEN OPEN TO STAIRCASE BEYOND RAILING AT 36" A.F.F. MAIN LEVEL 178'-2" GRADE 176'-10" 12'-10 3/8" WINDER Issue Date 8'-2" TREAD (N) FULL HEIGHT WALL (N) HALF WALL BEYOND 5'-3" BEHIND PANTRY CABINETS WINDER TREAD TO LANDING BASEMENT FF 170'-0" Drawn by:Author WALL SECTIONS AND STAIRS Scale: 3 Stair Section 3 MAIN LEVEL 178'-2" As indicated 1/4" = 1'-0" A2.0 (E) 2X8 FLOOR JOISTS EXTEND FOAM TO TOP OF CONCRETE GRADE 176'-10" FL2-FLOOR OVER CRAWLSPACE: • FINISH FLOORING PER OWNER SPEC. W5-2x4 BASEMENT WALL: • 3/4 T&G FLOOR SHEATHING • NO WATERPROOF COATING ON CONCRETE (N) CRAWLSPACE • 11 7/8 TJI 2' CLEARANCE • 2" RIGID EPS FOAM • BATT INSULATION R-30 • 2X4 STUD WALL W/ MINERAL WOOL INSUL. R-15 10 MIL VAPOR BARRIER • VENTED CRAWLSPACE • 1/2" GYPSUM • 10MIL VAPOR BARRIER OVER • NON-PVA WALL PRIMER GROUND • LOW OR NO VOC LATEX PAINT 1 Section 1 - Callout 1 1" = 1'-0" A4.1 309 S DUNHAM AVEARLINGTON, WA 309 S DUNHAM AVE ADDITION Job No.: 23-15 A4.2 Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. No. 1 3D NW Porch Issue Date 3D EXTERIOR Drawn by:Author Scale: ARLINGTON, WA 309 S DUNHAM AVE 309 S DUNHAM AVE ADDITION 2 3D NE Rear Porch Job No.: 23-15 A5.0 Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. No. 1 3D SE Rear Porch Issue Date 3D EXTERIOR Drawn by:Author Scale: ARLINGTON, WA 309 S DUNHAM AVE 309 S DUNHAM AVE ADDITION Job No.: 23-15 A5.1 Date Copyright 2020 Sno Valley Cottages, LLC All rights reserved. No. Issue Date 3D INTERIOR Drawn by:Author Scale: 1 3D BIRDSEYE INTERIOR ARLINGTON, WA 309 S DUNHAM AVE 309 S DUNHAM AVE ADDITION Job No.: 23-15 2 3D BIRDSEYE INTERIOR REAR A5.2 1 2 3 4 5 6 7 8 2 3/4" 2 3/4" I SONOTUBE O/24" BIG FOOT BF24 FOOTING VERIFY WITH STRUC. CONFIRMED. CAST 5/8" Ø ANCHOR ROD 6" INTO SONOTUBE TO RECEIVE 28'-0 1/2" SIMPSON ABU66Z POST BASE. 14'-0 1/4" 14'-0 1/4" 24" W X 12" CONCRETE 30" WIDE x 14" DP CONCRETE FOOTIN GWITH (2) #5 FOOTING WITH (3) #5 BOTTOM BOTTOM BARS BARS EACH WAY BELOW POST ABOVE. 11 H S-2.0 NEW CONCRETE STEMWALL 6" THICK 3'-0" WITH #4 BAR TOP AND BOTTOM AND VERTICALS #4 BARS @ 24" OC G SIMPSON STHD14 DOWEL AND EPOXY HOLD DOWN 2'-0" NEW WALL NEW CONCRETE FOOTING 12" 30" SQ x 14" DP CONCRETE FOOTING 11'-4 1/2" WIDE x 6" DP WITH (2) #4 BARS 6" STEM WALL ~2' TALL WITH (3) #5 BOTTOM BARS EACH WAY. TYPICAL AT (3) 16" X 8" D FOOTING BELOW NOT DRIVING DIMENSION 15'-0" BOTTOM OF FOOTING 2'-0" BELOWREBAR PER STRUC. LOCATIONS 12 TOP OF GRADE TO DECREASE EFFECT PROPOSED ADDITION8 DRIVING DIMENSION S-2.0 12'-0"ON ADJACENT BASEMENT WALL S-2.0 VENTED CRAWLSPACE TYPICAL DOWEL AND EPOXY NEW WALL F 1 S-2.0 EXISTING FULL HEIGHT BASEMENT FOUNDATION WALL OLD ADDITION STEM WALLS 1 3'-0" S-2.0 E Copyright 2020 Sno Valley Cottages, LLC All rights reserved. DRILL AND EPOXY 1/2" Ø CAST 5/8" Ø ANCHOR ROD 6" 11 ANCHOR ROD 6" INTO TOP INTO SONOTUBE TO RECEIVE No. Date S-3.0 OF EXISTING CONCRETE SIMPSON ABU66Z POST BASE. WALL. NOT FOR CONSTRUCTION WH 24" SQ x 12" DP CONCRETE CAST 5/8" Ø ANCHOR ROD 6" FOOTING WITH (2) #5 INTO SONOTUBE TO RECEIVE BOTTOM BARS EACH WAY. SIMPSON ABU66Z POST BASE. Issue Date D FOUNDATION PLAN NOTES: 1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0, S-1.1, AND S-1.2. C EXISTING BASEMENT Drawn by:Author 2.CONTRACTOR SHALL LOCATE AND VERIFY THE FOLLOWING WITH OTHERS PRIOR TO POURING CONCRETE: ALL DOOR OPENINGS AND BLOCKOUTS IN FOUNDATION WALLS; DRAINS AND SLOPES; ALL DUCTS, CHASES AND PIPES PER MECHANICAL, PLUMBING AND ELECTRICAL. FOUNDATION & FRAMING PLAN 3.TOP OF SLAB ON GRADE ELEVATION ASSUMED 0’-0”. PROVIDE 6 MIL POLYETHELENE VAPOR BARRIER BELOW SLAB ON GRADE AT INTERIOR SPACES. Scale: B 1/4" = 1'-0" 4.TOP OF WALL TO BE A MILNIMUM OF 8” ABOVE FINISHED GRADE. DAMPROOF WALLS BY OTHERS. 5.ALL FOOTINGS AND SLABS TO BEAR ON COMPETENT NATIVE SOIL AND/OR STRUCTURAL FILL. SUBGRADE PREPARATION, STRUCTURAL FILL, FOOTING DRAINS, AND OTHER A REQUIREMENTS PER GEOTECH REPORT AS NOTED IN THE STRUCTURAL GENERAL NOTES. 6.ALL REINFORCING TO BE GRADE 60. PROVIDE 3” CLEAR COVER FROM BOTTOM OF 9 FOOTING. 7.ALL WOOD EXPOSED TO CONRETE, WEATHER, OR WITHIN 8” OF FINISHED GRADE SHALL BE PRESSURE-TREATED. 8.PROVIDE HOT-DIPPED GALVANAIZED ANCHOR BOLTS AT PRESSURE TREATED SILL PLATES. 9.ADDITIONAL TYPICAL DETAILS NOT CUT ON PLAN PER S-2.0 SHEETS. NOT ALL DETAILS MAY BE APPLICABLE. 1 FOUNDATION PLAN 1/4" = 1'-0" ARLINGTON, WA 309 S DUNHAM AVE VIRTUS STAMP AND SCOPE 309 S DUNHAM AVE ADDITION ENCOMPASSES THE PRIMARY STRUCTURAL ELEMENTS AS SHOWN IN THE REDLINE MARKUPS, ONLY. PROJECT: SMITH REMODEL PROJECT NUMBER: 24081-0106 DATE: 01/16/2025 Job No.: 23-15 DESCRIPTION: FOUNDATION PLAN DRAWN BY: CDA A3.1 _______ - 28'-0 1/2" 14'-0 1/4" 14'-0 1/4" 9 1 - 2 3 4 5 6 7 8 9 _______ --- 1 2 3 4 5 6 7 8 H DIM. TO CL OF POST - _______ I --- G (N)GLULAM BEAM ABV. 39'-1 7/8" COVERED PORCH ADDITION VAULTED CEILING 4/12 SLOPE (N) VENTED CRAWLSPACE (N) FOUNDATION, SEE FDN PLAN GUARDRAILS REQUIRED IF DECK SURFACE MORE THAN 30" ABOVE GRADE - _______ --- WINDER REQUIRED 12'-9 1/4" TO MEET HEADROOM (E) FOUNDATION, SEE FDN PLAN PER CODE-6'-8" MIN. 13'-9 1/4" 14'-3 1/4" NEW ADDITION 9'-4 3/4" 4'-4 1/2" 2'-7 1/4" 4'-7" 4'-7" 2'-6" 4'-1" F DIM. TO F2 F1 FACE OF DIM. TO CONC. 10'-0 3/8" 2'-5 1/2" 6'-8 1/2" 9'-3 3/8" 9'-8 1/8" FACE OF 9'-4 3/4" 4'-4 1/2" D2 CONC. E (E) VENTED CRAWLSPACE H W4 F5 F4 F3 - _______ 3'-0" --- W4 - 4'-0" 2 NEW ADDITION _______ --- = W5 D13 (N) BATH G 4'-3" (N) BEDROOM 3 3'-2 3/4"D21 3'-6" STUD AND SHEAR WALL PLAN NOTES: 5'-10 1/4" DW DN CL. (N) STORAGE 5'-9 1/2"1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0, (N) DINING S-1.1, AND S-1.2. EGRESS REMOVE WINDOW D3 9'-0 1/2" = AND FILL IN WITH 11'-4 1/2" F23 2.LUMBER GRADE PER STRUCTURAL GENERAL NOTES.FRAMING ALIGN NEW FRAMING CONVERT TO EGRESS WINDOW STAIRS: W4 TO CORNER (E) WALL SILL AT +44" A.F.F. MAX. 14RISERS 3'-9 3/4" (N) KITCHEN AT 7" 3.ALL INTERIOR NON-BEARING, NON-STRUCTURAL WALL STUD REQUIREMENTS PER2X4 INTERIOR WALL, TYP. VAULTED CEILING 4/12 SLOPE REMOVE SIDING 13'-3 7/8" WH 1/2" AIR GAP FROM CONCRETE ON EXT. WALL 5'-6 1/4" S LINEN S STRUCTURAL GENERAL NOTES. 12'-0" 2'-0" W3 F22 13'-0 1/8" STAIR OPENING Range D18 D17 D16 5'-10" 3'-6 5/8" 4.UNLESS NOTED OTHERWISE ON PLAN: HEADERS TO BE (2) 2x8, TO BE SUPPORTED BY (1) 7'-8 3/8"TRIMMER AND (1) KING STUD MINIMUM, CONNECTION HEADERS INTO KING STUD WITH (4) FULL HEIGHT WALL F 3'-10" D19 6x6 POST D15 STUB FOR TOTAL 10d END NAILS EACH SIDE. KING STUDS TO BE CONNECTED TOP AND BOTTOM WITH 6'-4 7/8" S/CM 7'-9 1/8" STAIR OPENING FUTURE SINK 1 (E) WIN. COULD REMAIN 24'-0" 3'-11 5/8" GRINDER (4) 10d TOE NAILS, UNLESS NOTED OTHERWISE ON PLAN. (N) MECH. 2'-9 7/8" PUMP STORAGE CL VANITY ABV. ISLAND 10' X 5' S PANTRY (E) MASTER BEDROOM CLOSET 5.ALL TRIMMERS TO BE CONTINUOUS TO FOUNDATION. 7'-10 1/8" D DBL OvenOVEN E 28'-0" ALIGN 8'-1 1/4" D14 CL TOILET ABV. 6x6 POST 6x6 POST 3'-6 5/8" 6.ALL BEAMS, EXCLUDING HEADERS, SHOWN ON FRAMING PLAN SHALL BE SUPPORTED BY (2) ALIGN WALL ON CENTER W/POST - FLUSH INSIDE FACE OF WALL BUNDLED STUDS OR 4X MEMBER, MINIMUM UNLESS NOTED OTHERWISE ON PLAN. ALL_______ 9'-0 5/8" 28'-0" EXISTING BASEMENT OF POST 7'-2" --- (N) SKYLIGHT OVER THE STAIRS TO INSIDE FACE OF BEAM BUNDLED STUDS TO BE CONTINUOUS TO FOUNDATION.(N)GLULAM 2'-0" C BEAM ABV. (E) DOOR OPENING Refrigerator CL SHOWER DRAIN ABV. ALTER AS NEEDED PER DOOR CL VANITY ABV. 7.ALL EXTERIOR WALLS TO BE CONTINUOUSLY SHEATHED PER SHEAR WALL SCHEDULE 8'-10 1/8" W3 LOCATE WITHIN 3' OF PEAK D9 SELECTION F21 F24 W5 D20 11-S3.1 “UNBLOCKED W6”, UNLESS NOTED OTHERWISE ON PLAN. CL WASHER ABV. EGRESS Copyright 2020 Sno Valley Cottages, LLC All rights reserved. (N)6X6 POST-BEARING TO CABINETS/COUNTER 3'-3 1/2" 2'-10 1/4" 4'-0 1/8" 2'-4" 2'-6" (N) OFFICE (N) BONUS ROOM 8.ALL SHEAR WALLS INDICATED ON PLAN TO HAVE (2) BUNDLED STUDS AT WALL ENDS, 4'-0" F6 (N) WALL BELOW TO FTG. 6'-1 3/8" UNLESS NOTED OTHERWISE ON PLAN. HOLD DOWNS ARE AS INDICATED ON PLAN, AND MAY W1 No. Date 9'-4 3/4" F25 2'-1 1/2" CL TOILET ABV. 3'-4 1/2" NOT BE REQUIRED AT SOME WALLS. S (N) BATHROOM 13'-6" TO CL OF (E) BEAM AND POSTS 9.POST BASES AND CAPS, WHERE NECESSARY, ARE INDICATED ON PLAN. D8 CL. = B MATCH CL PLUMBING WALL ABV. DIM. TO = D10 CL SHOWER DRAIN ABV. 2'-11" 10.FABRICATE ALL STEEL COLUMNS -¼” PER FLOOR TO ALLOW FOR WOOD SHRINKAGE. WALL AT +42" A.F.F. D7 FACE OF 15'-8 1/2" W6 66" VANITY 5'-11 1/4" 4'-0" CONC. DN 4'-9" = 5'-4" 15'-11 1/4" TO STAIR OPENING CLOSET 11.WALL ANCHORAGE AND OTHER TYPICAL WALL FRAMING DETAILS PER SHEETS S-3.0 AND3'-10 7/8" = CONFIRM RO WITH POCKET DOOR SPECS 1'-4" MIRROR DIM. ON FIREPLACE CENTER 7'-9 1/8" (2)2X NOT FOR S-3.1. NOT ALL DETAILS MAY BE APPLICABLE.CONSTRUCTIONFIREPLACE D11 3 1/2" D 3'-3 1/2" SHOWER/TOILET A MATCH (N) GREAT ROOM = FLAT CEILING AT 7' 10-3/4" EXISTING RESIDENCE F20 4'-0" 2'-0" MIRROR DIM. ON FIREPLACE CENTER REBUILD FP AT INTERIOR (N)6x6 POST-BEARING TO METAL RAILING 3'-1" 3'-8 1/4"S/CM SHOWER 4'-3 1/2" F7 AT +36" A.F.F. 4' W X 3' D = Issue Date TO CENTER BEAM BELOW C - ON BEAMS ABV. AND STAIR D4 D5 _______ --- S ADD 2' X 2' SKYLIGHT ABOVE F8 7'-6" 9'-0 1/2" 30'-1 3/8" W1 (N) GLULAM BEAM ABV. 42" VANITY 4'-9 7/8" (N) BEDROOM 2 F19 Author F9 4'-2 1/2"4'-2 1/2" 3'-4 1/2"(N) BATH W2 1'-0" Drawn by: D12 5'-0" BENCH/CUBBIES/CABS 9'-7 5/8" B 2 BASEMENT LEVEL 7'-6" W3 F18 1/4" = 1'-0" 6'-2 7/8" 1'-4 3/8"1'-4 3/8" CLOSET F10 F11 F12 1'-3 1/2" 4'-5 1/2"2'-10" 2'-2" 2'-4 1/2" 6'-7 7/8" 6'-7 7/8" 4'-9 7/8" REMODEL/ADDITION FLOOR PLANS 3'-1 3/8" EGRESS Scale: FLOOR PLAN NOTES D1 As indicated SMOKE ALARMS AND HEAT DETECTION A FRAMING: 2X6 EXTERIOR WALLS REQUIRED LOCATIONS R314.3: FRAMING - DOOR SCH. 1'-6" 3'-0" 7'-6" SMOKE ALARMS/CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN: 2X4/6's AT INTERIOR WALLS UNLESS NOTED OTHERWISE 1. IN EACH SLEEPING ROOM OR SLEEPING LOFT NO. DOOR SIZE HEAD HEIGHT COMMENTS F13 F14 F15 F16 F17 FILL IN 2X4 FRAMING 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE BASEMENT FF AT ALL MODIFIED SEE STRUCTURAL NOTES FOR STUD SCHEDULE. VICINITY OF THE BEDROOMS. D13 2'-6" 6'-8" 6'-8" COVERED WINDOW OPENINGS 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING CONCEALED SPACES SHALL BE FIRESTOPPED IN BOTH DIRECTIONS AT BASEMENTS AND HABITABLE ATTICS. D14 2'-10" 6'-8" 6'-8" NEW ADDITION - PORCH 10" ON CENTER AND AT FLOORS. TYPICAL. 4. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET FROM D15 2'-6" 6'-8" 6'-8" _______ --- THE DOOR OR OPENING OF A BATHROOM. D16 2'-4" 6'-8" 6'-8" ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH D17 1'-8" 6'-8" 6'-8" DN HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. THE LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER D18 2'-6" 6'-8" 6'-8" MINIMUM CLEAR OPENING HEIGHT DIMENSION SHALL BE 24". MINIMUM THAN 24". CLEAR OPENING WIDTH DIMENSION SHALL BE 20". SILL HEIGHT SHALL D19 2'-6" 6'-8" 6'-8" NOT BE MORE THAN 44" ABOVE THE FLOOR. ALTERATIONS, REPAIRS AND ADDITIONS R314.2.2 WHERE ALTERATIONS, D20 2'-6" 6'-8" 6'-8" REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHERE ONE OR D21 5'-0" 6'-8" 6'-8" SHOWER COMPARTMENTS AND WALLS AROUND BATHTUBS WITH MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DEMO 2'-6" 6'-8" 6'-8" SHOWERS SHALL BE FINISHED WITH A SMOOTH NON-ABSORBANT DWELLINGS, OR WHERE AN ACCESSORY DWELLING UNIT IS CREATED DEMO 2'-6" 6'-8" 6'-8" SURFACE TO NOT LESS THAN 72" ABOVE THE FLOOR (IRC R307.2). WITHIN AN EXISTING DWELLING UNIT, EACH DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS AS REQUIRED FOR NEW DWELLINGS. MAIN LEVEL ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN D1 3'-0" 6'-8" 6'-8" D2 1 MAIN LEVEL OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM OF 3/4" D2 6'-0" 6'-8" 6'-8" 1/4" = 1'-0" ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D3 6'-0" 6'-8" 6'-8" DOOR AND TRANSFER GRILLE ABOVE DOOR. HEAT DETECTION INTERCONNECTION R314.4.1 HEAT DETECTORS AND HEAT ALARMS SHALL BE CONNECTED TO AN ALARM OR A SMOKE ALARM D4 2'-6" 6'-8" 6'-8" PROVIDE WEATHER RESISTANT FIBER CEMENT WALLBOARD UNDER TUB THAT IS INSTALLED IN THE DWELLING. ALARMS THAT ARE INSTALLED FOR D5 2'-8" 6'-8" 6'-8" AND SHOWER ENCLOSURE MATERIALS TO A HEIGHT OF 70" MINIMUM THIS PURPOSE SHALL BE LOCATED IN A HALLWAY, ROOM, OR OTHER D6 2'-6" 6'-8" 6'-8" ABOVE THE DRAIN INLET. LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION. D7 2'-6" 6'-8" 6'-8" FLOOR PLAN KEY NOTES ARLINGTON, WA D8 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN COMBINATION ALARMS R314.5 COMBINATION SMOKE AND CARBON OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM ? 3/4" MONOXIDE ALARMS MAY BE USED IN PLACE OF SMOKE ALARMS. D9 6'-0" 6'-8" 6'-8" NO. DESCRIPTION ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D10 5'-0" 6'-8" 6'-8" 1 EXISTING SEWER ~5' ABOVE FFE DOOR AND TRANSFER GRILLE ABOVE DOOR. POWER SOURCE R314.6 SMOKE ALARMS, HEAT ALARMS, AND HEAT D11 2'-6" 6'-8" 6'-8" 2 EXISTING ELECTRICAL PANEL-150 AMP, UPGRADE TO 200 AMP DETECTORS SHALL RECEIVE PRIMARY POWER FROM THE BUILDING D12 5'-0" 6'-8" 6'-8" 1. A CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH WIRING AND, WHEN POWER IS INTERRUPTED, SHALL RECEIVE POWER SEPARATE SLEEPING AREA IN IMMEDIATE VICINITY OF BEDROOMS D22 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ADDITION FROM A BATTERY. VIRTUS STAMP AND SCOPE AND ON EACH LEVEL PER 2015 IRC R315. DEMO 2'-0" 6'-8" 6'-8" ENCOMPASSES THE PRIMARY 2. A SMOKE DETECTOR SHALL BE INSTALLED IN EACH HABITABLE ROOM. INTERCONNECTIVITY R314.4 WHERE MORE THAN ONE SMOKE ALARM IS DEMO 2'-4" 6'-8" 6'-8" 3. A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH REQUIRED TO BE INSTALLED, THE ALARM DEVICES SHALL BE DEMO 5'-0" 6'-8" 6'-8" STRUCTURAL ELEMENTS AS SHOWN FLOOR. INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE IN THE REDLINE MARKUPS, ONLY. DEMO 2'-6" 6'-8" 6'-8" 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING DEMO 2'-6" 6'-8" 6'-8" LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL NOT BE PROJECT: SMITH REMODEL PROJECT NUMBER: 24081-0106 THAN 24". REQUIRED WHERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL DEMO 2'-0" 6'-8" 6'-8" 5. SMOKE DETECTORS SHALL BE 110V HARDWIRED, INTERCONNECTED, ALARMS SOUND UPON ACTIVATION OF ONE ALARM. Job No.: 23-15 WITH BATTERY BACKUP, PER 2015 IRC R314. WHERE AN ACCESSORY DWELLING UNIT IS CREATED WITHIN AN EXISTING DATE: 01/16/2025 NOTE: A SPRINKLER SYSTEM IS NOT REQUIRED FOR THIS RESIDENCE. DWELLING UNIT ALL REQUIRED SMOKE ALARMS, IN THE ACCESSORY DWELLING UNIT AND THE PRIMARY DWELLING UNIT, SHALL BE DESCRIPTION: BASEMENT POST PLAN DRAWN BY: CDA INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL ALARMS IN BOTH THE PRIMARY DWELLING UNIT A2.0 AND THE ACCESSORY DWELLING UNIT _______ - 28'-0 1/2" 11 14'-0 1/4" 14'-0 1/4" 9 2 3 5 S-3.2 6 7 9 1 - 4 8 _______ --- 1 2 3 4 5 6 7 8 H DIM. TO CL OF POST - _______ I --- G 6x6 POST 6x6 POST 6x6 POST (N)GLULAM BEAM ABV. 39'-1 7/8" COVERED PORCH ADDITION 12 VAULTED CEILING 4/12 SLOPE (N) FOUNDATION, SEE FDN PLAN GUARDRAILS REQUIRED IF DECK SURFACE (N) VENTED CRAWLSPACE S-3.2 TYPICAL AT NEW MORE THAN 30" ABOVE GRADE - CONSTRUCTION, UNLESS _______ 11 7/8" DP TJI 210 @ 24" OC 11 7/8" DP TJI 210 @ 24" OC NOTED OTHERWISE --- WINDER REQUIRED 12'-9 1/4" TO MEET HEADROOM (E) FOUNDATION, SEE FDN PLAN PER CODE-6'-8" MIN. 13'-9 1/4" 14'-3 1/4" NEW ADDITION 9'-4 3/4" 4'-4 1/2" 2'-7 1/4" 4'-7" 4'-7" 2'-6" 4'-1" GL 5 1/2" x 10 1/2" F DIM. TO F2 F1 NEW WALLS TO BE 2x6 @ 16" FACE OF DIM. TO CONC. 10'-0 3/8" 2'-5 1/2" 6'-8 1/2" 9'-3 3/8" 9'-8 1/8" FACE OF 9'-4 3/4" 4'-4 1/2" D2 OC WITH (3) 8d TOE NAILS TOP 3'-0" CONC. E 6x6 POST AND BOTTOM H (E) VENTED CRAWLSPACE W4 (2) 2x8 HDR F5 F4 F3 - _______ 6x6 POST 3'-0" W6 BLOCKED --- W4 - 4'-0" 2 NEW ADDITION SHEAR WALL _______ --- = W5 D13 (N) BATH G 4'-3" (N) BEDROOM 3 1 3'-2 3/4"D21 3'-6" (2) 2x8 HDR 5'-10 1/4" S-3.2 CL. (N) STORAGE DW DN 5'-9 1/2" 6x6 POST (N) DINING EGRESS REMOVE WINDOW D3 9'-0 1/2" = AND FILL IN WITH 11'-4 1/2" F23 FRAMING ALIGN NEW FRAMING CONVERT TO EGRESS WINDOW STAIRS: SILL AT +44" A.F.F. MAX. 14RISERS2x8 @ 24" OC, MIN W4 TO CORNER (E) WALL (2) 2x8 HDR 3'-9 3/4" (N) KITCHEN AT 7" 2X4 INTERIOR WALL, TYP. VAULTED CEILING 4/12 SLOPE REMOVE SIDING 13'-3 7/8" WH 1/2" AIR GAP FROM CONCRETE ON EXT. WALL 5'-6 1/4" S LINEN S 12'-0" 2'-0" W3 F22 13'-0 1/8" STAIR OPENING Range D18 D17 D16 5'-10" 3'-6 5/8" 4x8 7'-8 3/8" FULL HEIGHT WALL F 3'-10" D19 D15 STUB FOR 6'-4 7/8" S/CM 7'-9 1/8" STAIR OPENING FUTURE SINK 1 (E) WIN. COULD REMAIN 24'-0" 3'-11 5/8" GRINDER (N) MECH. 2'-9 7/8" PUMP W6 BLOCKED STORAGE CL VANITY ABV. ISLAND 10' X 5' S PANTRY (E) MASTER BEDROOM CLOSET SHEAR WALL 7'-10 1/8" D DBL OvenOVEN E 28'-0" ALIGN 8'-1 1/4" D14 CL TOILET ABV. 3'-6 5/8" ALIGN WALL ON CENTER W/POST - (4) 2x4 OR FLUSH INSIDE FACE OF WALL _______ 4x6 POST 9'-0 5/8" 28'-0" EXISTING BASEMENT OF POST 7'-2" --- 4x6 POST (N) SKYLIGHT OVER THE STAIRS TO INSIDE FACE OF BEAM (N)GLULAM C BEAM ABV. 2'-0" SIMPSON DTT2Z HOLD(E) DOOR OPENING Refrigerator CL VANITY ABV. CL SHOWER DRAIN ABV. DOWN ALTER AS NEEDED PER DOOR 8'-10 1/8" W3 LOCATE WITHIN 3' OF PEAK D9 SELECTION F21 F24 W5 D20 CL WASHER ABV. EGRESS Copyright 2020 Sno Valley Cottages, LLC All rights reserved. (N)6X6 POST-BEARING TO CABINETS/COUNTER 3'-3 1/2" 2'-10 1/4" 4'-0 1/8" 2'-4" 2'-6" (N) OFFICE (N) BONUS ROOM 4'-0" F6 (N) WALL BELOW TO FTG. 6'-1 3/8" W1 No. Date 9'-4 3/4" F25 2'-1 1/2" CL TOILET ABV. 3'-4 1/2" S (2) 2x8 HDR (N) BATHROOM 13'-6" TO CL OF (E) BEAM AND POSTS D8 CL. = B MATCH CL PLUMBING WALL ABV. DIM. TO = D10 CL SHOWER DRAIN ABV. 2'-11" WALL AT +42" A.F.F.6x6 POST D7 FACE OF 15'-8 1/2" W6 66" VANITY 5'-11 1/4" 4'-0" CONC. DN 4'-9" = 5'-4" 15'-11 1/4" TO STAIR OPENING CLOSET 3'-10 7/8" 1'-4" MIRROR DIM. ON FIREPLACE CENTER 7'-9 1/8" = CONFIRM RO WITH POCKET DOOR SPECS (2)2X NOT FOR CONSTRUCTIONFIREPLACE D11 3 1/2" D 3'-3 1/2" SHOWER/TOILET A MATCH (N) GREAT ROOM = EXISTING RESIDENCE FLAT CEILING AT 7' 10-3/4"6x6 POST 6x6 POST 4'-0" 2'-0"F20 MIRROR DIM. ON FIREPLACE CENTER REBUILD FP AT INTERIOR (N)6x6 POST-BEARING TO METAL RAILING 3'-1" 3'-8 1/4"S/CM SHOWER 4'-3 1/2" F7 AT +36" A.F.F. 4' W X 3' D = Issue Date TO CENTER BEAM BELOW C - ON BEAMS ABV. AND STAIR D4 D5 _______ --- S ADD 2' X 2' SKYLIGHT ABOVE F8 7'-6" 9'-0 1/2" 30'-1 3/8" W1 (N) GLULAM BEAM ABV. 42" VANITY 4'-9 7/8" (2) 2x12 HDR (N) BEDROOM 2 F19 Author F9 4'-2 1/2"4'-2 1/2" 3'-4 1/2"(N) BATH W2 1'-0" Drawn by: D12 5'-0" BENCH/CUBBIES/CABS 9'-7 5/8" B 2 BASEMENT LEVEL 7'-6" W3 F18 1/4" = 1'-0" 6'-2 7/8" 1'-4 3/8"1'-4 3/8" CLOSET F10 F11 F12 1'-3 1/2" 4'-5 1/2"2'-10" 2'-2" 2'-4 1/2" 6'-7 7/8" 6'-7 7/8" 4'-9 7/8" FLOOR FRAMING PLAN NOTES: STUD AND SHEAR WALL PLAN NOTES: 3'-1 3/8" REMODEL/ADDITION FLOOR PLANS FLOOR PLAN NOTES1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0, 1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0, D1 EGRESS Scale: As indicated SMOKE ALARMS AND HEAT DETECTION S-1.1, AND S-1.2. A S-1.1, AND S-1.2. REQUIRED LOCATIONS R314.3: 1'-6"4x6 POST 3'-0" 7'-6" FRAMING: 2X6 EXTERIOR WALLS FRAMING - DOOR SCH. SMOKE ALARMS/CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN: 2X4/6's AT INTERIOR WALLS 2.LUMBER GRADE PER STRUCTURAL GENERAL NOTES. UNLESS NOTED OTHERWISE2.ALL DUCTS CHASES AND PIPES SHALL BE PER MECHANICAL, PLUMBING, ELECTRICAL AND1. IN EACH SLEEPING ROOM OR SLEEPING LOFT NO. DOOR SIZE HEAD HEIGHT COMMENTS F13 F14 F15 F16 F17 FILL IN 2X4 FRAMING 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE SPRINKLER DRAWINGS. BASEMENT FF AT ALL MODIFIED SEE STRUCTURAL NOTES FOR STUD SCHEDULE. VICINITY OF THE BEDROOMS. D13 2'-6" 6'-8" 3.ALL INTERIOR NON-BEARING, NON-STRUCTURAL WALL STUD REQUIREMENTS PER6'-8" COVERED WINDOW OPENINGS 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING CONCEALED SPACES SHALL BE FIRESTOPPED IN BOTH DIRECTIONS AT 3.23/32 FLOOR SHEATHING PER STUCTURAL GENERAL NOTES. SHEATHING TO BE GLUEDBASEMENTS AND HABITABLE ATTICS. D14 2'-10" 6'-8" STRUCTURAL GENERAL NOTES.6'-8" NEW ADDITION - PORCH 10" ON CENTER AND AT FLOORS. TYPICAL.AND NAILED TO FLOOR FRAMING WITH 8d X 2 ½4. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET FROM” COMMON WIRE NAILS @ 6” OC AT D15 2'-6" 6'-8" 6'-8" _______ --- SUPPORTED PANEL EDGES, AND 12” OC FIELD NAILING. LAY SHEATHING THE LONGTHE DOOR OR OPENING OF A BATHROOM. D16 2'-4" 6'-8" 4.UNLESS NOTED OTHERWISE ON PLAN: HEADERS TO BE (2) 2x8, TO BE SUPPORTED BY (1)6'-8" ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH DIRECTION PERPENDICULAR TO SUPPORTS AND STAGGER PANEL END JOINTS. ALLOW 1/8LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER” D17 1'-8" 6'-8" TRIMMER AND (1) KING STUD MINIMUM, CONNECTION HEADERS INTO KING STUD WITH (4)6'-8" DN HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. THE D18 2'-6" 6'-8" TOTAL 10d END NAILS EACH SIDE. KING STUDS TO BE CONNECTED TOP AND BOTTOM WITH6'-8" MINIMUM CLEAR OPENING HEIGHT DIMENSION SHALL BE 24". MINIMUM SPACE BETWEEN PANEL ENDS AND EDGES. THAN 24". CLEAR OPENING WIDTH DIMENSION SHALL BE 20". SILL HEIGHT SHALL D19 2'-6" 6'-8" (4) 10d TOE NAILS, UNLESS NOTED OTHERWISE ON PLAN.6'-8" NOT BE MORE THAN 44" ABOVE THE FLOOR.4.ALL WOOD EXPOSED TO CONCRETE, WEATHER, OR WITHIN 8ALTERATIONS, REPAIRS AND ADDITIONS R314.2.2 ” OF FINISHED GRADE SHALLWHERE ALTERATIONS, D20 2'-6" 6'-8" 6'-8" REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHERE ONE OR D21 5'-0" 6'-8" 5.ALL TRIMMERS TO BE CONTINUOUS TO FOUNDATION.6'-8" SHOWER COMPARTMENTS BE PRESSURE TREATED.AND WALLS AROUND BATHTUBS WITH MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DEMO 2'-6" 6'-8" 6'-8" SHOWERS SHALL BE FINISHED WITH A SMOOTH NON-ABSORBANT DWELLINGS, OR WHERE AN ACCESSORY DWELLING UNIT IS CREATED SURFACE TO NOT LESS THAN 72" ABOVE THE FLOOR (IRC R307.2). WITHIN AN EXISTING DWELLING UNIT, EACH DWELLING UNIT SHALL BE DEMO 2'-6" 6'-8" 6.ALL BEAMS, EXCLUDING HEADERS, SHOWN ON FRAMING PLAN SHALL BE SUPPORTED BY (2)6'-8" 5.ALL 2X HANGERS TO BE TOP FLANGE BEARING SIMPSON JB TYPE, UNLESS NOTED EQUIPPED WITH SMOKE ALARMS AS REQUIRED FOR NEW DWELLINGS. MAIN LEVEL BUNDLED STUDS OR 4X MEMBER, MINIMUM UNLESS NOTED OTHERWISE ON PLAN. ALL OTHERWISE. ANY HANGERS REQUIRED AT BEAMS ARE SPECIFIED ON PLAN. I JOIST ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN D1 3'-0" 6'-8" BUNDLED STUDS TO BE CONTINUOUS TO FOUNDATION.6'-8" D2 1 MAIN LEVEL OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM OF 3/4"HANGERS TO BE TOP FLANGE BEARING SIMPSON MIT OR ITS TYPE, UNLESS NOTED D2 6'-0" 6'-8" 6'-8" 1/4" = 1'-0" ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDEROTHERWISE. D3 6'-0" 6'-8" 6'-8" DOOR AND TRANSFER GRILLE ABOVE DOOR. HEAT DETECTION INTERCONNECTION R314.4.1 HEAT DETECTORS AND 7.ALL EXTERIOR WALLS TO BE CONTINUOUSLY SHEATHED PER SHEAR WALL SCHEDULE HEAT ALARMS SHALL BE CONNECTED TO AN ALARM OR A SMOKE ALARM D4 2'-6" 6'-8" 6'-8" 6.BEAMS ARE FLUSH FRAMED WITH JOISTS, UNLESS NOTED OTHERWISE ON DETAILS, OR ON 11-S3.1 “UNBLOCKED W6”, UNLESS NOTED OTHERWISE ON PLAN. PROVIDE WEATHER RESISTANT FIBER CEMENT WALLBOARD UNDER TUB THAT IS INSTALLED IN THE DWELLING. ALARMS THAT ARE INSTALLED FOR D5 2'-8" 6'-8" 6'-8" AND SHOWER ENCLOSURE MATERIALS TO A HEIGHT OF 70" MINIMUM PLANS AS “DB.” DB INDICTES A “DROPPED BEAMTHIS PURPOSE SHALL BE LOCATED IN A HALLWAY, ROOM, OR OTHER” WHICH IS FRAMED BELOW THE FLOOR. D6 2'-6" 6'-8" 6'-8" ABOVE THE DRAIN INLET.WHERE BEAMS ARE NOT SUPPORTED BY HANGERS, SUPPORT IS PER THE STUD AND SHEARLOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION. D7 2'-6" 6'-8" 8.ALL SHEAR WALLS INDICATED ON PLAN TO HAVE (2) BUNDLED STUDS AT WALL ENDS,6'-8" ARLINGTON, WA WALL PLAN. PROVIDE A35 CLIPS EA SIDE OF BEAMS THAT BEAR ON DOUBLE TOP PLATES. D8 2'-6" 6'-8" UNLESS NOTED OTHERWISE ON PLAN. HOLD DOWNS ARE AS INDICATED ON PLAN, AND MAY6'-8" FLOOR PLAN KEY NOTES 309 S DUNHAM AVE ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN COMBINATION ALARMS R314.5 COMBINATION SMOKE AND CARBON NOT BE REQUIRED AT SOME WALLS. OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM ? 3/4" MONOXIDE ALARMS MAY BE USED IN PLACE OF SMOKE ALARMS. D9 6'-0" 6'-8" 6'-8" NO. DESCRIPTION ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER 7.WOOD “I-JOISTS” TO BE DESIGNED BY OTHERS. SUBMITTAL INFORMATION, DESIGN D10 5'-0" 6'-8" 6'-8" 1 EXISTING SEWER ~5' ABOVE FFE DOOR AND TRANSFER GRILLE ABOVE DOOR. CRITERIA, RIM JOIST, AND BLOCKING REQUIREMENTS PER STRUCTURAL GENERAL NOTES.POWER SOURCE R314.6 SMOKE ALARMS, HEAT ALARMS, AND HEAT D11 2'-6" 6'-8" 9.POST BASES AND CAPS, WHERE NECESSARY, ARE INDICATED ON PLAN.6'-8" 2 EXISTING ELECTRICAL PANEL-150 AMP, UPGRADE TO 200 AMP DETECTORS SHALL RECEIVE PRIMARY POWER FROM THE BUILDING D12 5'-0" 6'-8" 6'-8" 1. A CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH WIRING AND, WHEN POWER IS INTERRUPTED, SHALL RECEIVE POWER D22 2'-6" 6'-8" 10.FABRICATE ALL STEEL COLUMNS -¼6'-8" ” PER FLOOR TO ALLOW FOR WOOD SHRINKAGE. SEPARATE SLEEPING AREA IN IMMEDIATE VICINITY OF BEDROOMS 8.ALL RIM JOISTS TO BE 1 ½” LSL MINIMUM, UNLESS OTHERWISE NOTED ON PLAN.FROM A BATTERY. VIRTUS STAMP AND SCOPE 309 S DUNHAM AVE ADDITION AND ON EACH LEVEL PER 2015 IRC R315. DEMO 2'-0" 6'-8" 6'-8" ENCOMPASSES THE PRIMARY 2. A SMOKE DETECTOR SHALL BE INSTALLED IN EACH HABITABLE ROOM.9.BEARING STUD, SHEAR WALL, HOLD-DOWN, POST SIZE, AND POST CAP AND BASEINTERCONNECTIVITY R314.4 WHERE MORE THAN ONE SMOKE ALARM IS DEMO 2'-4" 6'-8" 11.WALL ANCHORAGE AND OTHER TYPICAL WALL FRAMING DETAILS PER SHEETS S-3.0 AND6'-8" 3. A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH REQUIREMENTS BELOW PER STUD AND SHEAR WALL PLAN.REQUIRED TO BE INSTALLED, THE ALARM DEVICES SHALL BE DEMO 5'-0" 6'-8" S-3.1. NOT ALL DETAILS MAY BE APPLICABLE.6'-8" STRUCTURAL ELEMENTS AS SHOWN FLOOR. INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE IN THE REDLINE MARKUPS, ONLY. DEMO 2'-6" 6'-8" 6'-8" 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING DEMO 2'-6" 6'-8" 6'-8" LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER 10.FABRICATE ALL STEEL COLUMNS -1/4” PER FLOOR TO ALLOW FOR WOOD SHRINKAGE.UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL NOT BE PROJECT: SMITH REMODEL PROJECT NUMBER: 24081-0106 THAN 24". REQUIRED WHERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL DEMO 2'-0" 6'-8" 6'-8" 5. SMOKE DETECTORS SHALL BE 110V HARDWIRED, INTERCONNECTED, ALARMS SOUND UPON ACTIVATION OF ONE ALARM. 11.TYPICAL DETAILS PER S-3.2. NOT ALL DETAILS MAY BE APPLICABLE. Job No.: 23-15 WITH BATTERY BACKUP, PER 2015 IRC R314. WHERE AN ACCESSORY DWELLING UNIT IS CREATED WITHIN AN EXISTING DATE: 01/16/2025 NOTE: A SPRINKLER SYSTEM IS NOT REQUIRED FOR THIS RESIDENCE. DWELLING UNIT ALL REQUIRED SMOKE ALARMS, IN THE ACCESSORY DWELLING UNIT AND THE PRIMARY DWELLING UNIT, SHALL BE DESCRIPTION: MAIN LEVEL FRAMING, AND MAIN LEVEL STUD DRAWN BY: CDA INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE AND SHEAR WALL PLANS ALARM WILL ACTIVATE ALL ALARMS IN BOTH THE PRIMARY DWELLING UNIT A2.0 AND THE ACCESSORY DWELLING UNIT _______ - 28'-0 1/2" 14'-0 1/4" 14'-0 1/4" 9 1 - 2 3 4 5 6 7 8 9 _______ --- 1 2 3 4 5 6 7 8 H DIM. TO CL OF POST - _______ I --- G (N)GLULAM BEAM ABV. 39'-1 7/8" COVERED PORCH ADDITION VAULTED CEILING 4/12 SLOPE (N) VENTED CRAWLSPACE (N) FOUNDATION, SEE FDN PLAN GUARDRAILS REQUIRED IF DECK SURFACE MORE THAN 30" ABOVE GRADE - _______ --- WINDER REQUIRED 12'-9 1/4" TO MEET HEADROOM (E) FOUNDATION, SEE FDN PLAN PER CODE-6'-8" MIN. 13'-9 1/4" 14'-3 1/4" NEW ADDITION 9'-4 3/4" 4'-4 1/2" 2'-7 1/4" 4'-7" 4'-7" 2'-6" 4'-1" F DIM. TO F2 F1 FACE OF DIM. TO CONC. 10'-0 3/8" 2'-5 1/2" 6'-8 1/2" 9'-3 3/8" 9'-8 1/8" FACE OF 9'-4 3/4" 4'-4 1/2" D2 CONC. E (E) VENTED CRAWLSPACE H W4 F5 F4 F3 - _______ 3'-0" --- W4 - 4'-0" 2 NEW ADDITION _______ --- = W5 D13 (N) BATH G 4'-3" (N) BEDROOM 3 3'-2 3/4"D21 3'-6" 5'-10 1/4" DW DN CL. (N) STORAGE 5'-9 1/2" (N) DINING EGRESS REMOVE WINDOW D3 9'-0 1/2" = AND FILL IN WITH 11'-4 1/2" F23 FRAMING ALIGN NEW FRAMING CONVERT TO EGRESS WINDOW STAIRS: W4 TO CORNER (E) WALL SILL AT +44" A.F.F. MAX. 14RISERS 3'-9 3/4" (N) KITCHEN AT 7" 2X4 INTERIOR WALL, TYP. VAULTED CEILING 4/12 SLOPE REMOVE SIDING 13'-3 7/8" WH 1/2" AIR GAP FROM CONCRETE ON EXT. WALL 5'-6 1/4" S LINEN S 12'-0" 2'-0" W3 F22 13'-0 1/8" STAIR OPENING Range D18 D17 D16 5'-10" 3'-6 5/8" 7'-8 3/8" FULL HEIGHT WALL6x6 ON TOP OF F 3'-10" D19 D15 STUB FOR GLULAM. SIMPSON6'-4 7/8" S/CM 7'-9 1/8" STAIR OPENING FUTURE SINK 1 (E) WIN. COULD REMAIN 24'-0" GRINDER BC60 HALF BASE 3'-11 5/8" (N) MECH. 2'-9 7/8" PUMP STORAGE CL VANITY ABV. ISLAND 10' X 5' S PANTRY (E) MASTER BEDROOM CLOSET 7'-10 1/8" D DBL OvenOVEN E 28'-0" ALIGN 8'-1 1/4" D14 CL TOILET ABV. GL 5 1/2" x 16" 3'-6 5/8" ALIGN WALL ON CENTER W/POST - SIMPSON BA FLUSH INSIDE FACE OF WALL _______ 9'-0 5/8" 28'-0" EXISTING BASEMENT OF POST 7'-2" --- (N) SKYLIGHT OVER THE STAIRS TO INSIDE FACE OF BEAM HANGER (N)GLULAM 2'-0" C BEAM ABV. (E) DOOR OPENING Refrigerator CL SHOWER DRAIN ABV. 4x4 POST ABOVE ALTER AS NEEDED PER DOOR CL VANITY ABV. 2x8 @ 24" OC 8'-10 1/8" WINDOW HEADER W3 LOCATE WITHIN 3' OF PEAK D9 SELECTION F21 F24 W5 D20 SISTERED TO (E) 2x6 CL WASHER ABV. EGRESS Copyright 2020 Sno Valley Cottages, LLC All rights reserved. (N)6X6 POST-BEARING TO CABINETS/COUNTER 3'-3 1/2" 2'-10 1/4" 4'-0 1/8" 2'-4" 2'-6" (N) OFFICE (N) BONUS ROOM 4'-0" F6 (N) WALL BELOW TO FTG. 6'-1 3/8" GL 5 1/2" x 10 1/2" W1 No. Date 9'-4 3/4" F25 6x6 ON TOP OF 2'-1 1/2" CL TOILET ABV. 3'-4 1/2" S GLULAM. SIMPSON (N) BATHROOM 13'-6" TO CL OF (E) BEAM AND POSTS BC60 HALF BASE D8 CL. = B MATCH CL PLUMBING WALL ABV. DIM. TO = D10 CL SHOWER DRAIN ABV. 2'-11" WALL AT +42" A.F.F. D7 FACE OF 15'-8 1/2" W6 SIMPSON HUC 66" VANITY 5'-11 1/4" 4'-0" CONC. DN 4'-9" = 5'-4" 15'-11 1/4" TO STAIR OPENING HANGER CLOSET 3'-10 7/8" 1'-4" MIRROR DIM. ON FIREPLACE CENTER 7'-9 1/8" = CONFIRM RO WITH POCKET DOOR SPECS (2)2X NOT FOR CONSTRUCTIONFIREPLACE D11 4x8 3 1/2" 3'-3 1/2" SHOWER/TOILET D A MATCH (N) GREAT ROOM6x6 ON TOP OF = FLAT CEILING AT 7' 10-3/4" 4x4 POST ABOVEEXISTING RESIDENCE GLULAM. SIMPSON F20 4'-0" 2'-0" WINDOW HEADERMIRROR DIM. ON FIREPLACE CENTER REBUILD FP AT INTERIOR BC60 HALF BASE(N)6x6 POST-BEARING TO METAL RAILING 3'-1" 3'-8 1/4"S/CM SHOWER 4'-3 1/2" F7 AT +36" A.F.F. 4' W X 3' D = Issue Date TO CENTER BEAM BELOW C - ON BEAMS ABV. AND STAIR D4 D5 _______ --- S ADD 2' X 2' SKYLIGHT ABOVE F8 7'-6" 9'-0 1/2" 30'-1 3/8" W1 (N) GLULAM BEAM ABV. 42" VANITY 4'-9 7/8" (N) BEDROOM 2 F19 Author F9 4'-2 1/2"4'-2 1/2" 3'-4 1/2"(N) BATH W2 1'-0" Drawn by: D12 5'-0" BENCH/CUBBIES/CABS 9'-7 5/8" B 2 BASEMENT LEVEL 7'-6" GL 5 1/2" x 10 1/2" W3 F18 1/4" = 1'-0" 6'-2 7/8" 1'-4 3/8"1'-4 3/8" CLOSET F10 F11 F12 1'-3 1/2" 4'-5 1/2"2'-10" 2'-2" 2'-4 1/2" 6'-7 7/8" 6'-7 7/8" 4'-9 7/8" REMODEL/ADDITION FLOOR PLANS 3'-1 3/8" ROOF FRAMING PLAN NOTES: EGRESS Scale: FLOOR PLAN NOTES D1 As indicated SMOKE ALARMS AND HEAT DETECTION 1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0, A FRAMING: 2X6 EXTERIOR WALLS REQUIRED LOCATIONS R314.3: S-1.1, AND S-1.2.FRAMING - DOOR SCH. 1'-6" 3'-0" 7'-6" SMOKE ALARMS/CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN: 2X4/6's AT INTERIOR WALLS UNLESS NOTED OTHERWISE 1. IN EACH SLEEPING ROOM OR SLEEPING LOFT NO. DOOR SIZE HEAD HEIGHT COMMENTS F13 F14 F15 F16 F17 FILL IN 2X4 FRAMING 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE 2.ALL DUCTS CHASES AND PIPES SHALL BE PER MECHANICAL, PLUMBING, ELECTRICAL AND BASEMENT FF AT ALL MODIFIED SEE STRUCTURAL NOTES FOR STUD SCHEDULE. VICINITY OF THE BEDROOMS. D13 2'-6" 6'-8"SPRINKLER DRAWINGS. 6'-8" COVERED WINDOW OPENINGS 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING CONCEALED SPACES SHALL BE FIRESTOPPED IN BOTH DIRECTIONS AT BASEMENTS AND HABITABLE ATTICS. D14 2'-10" 6'-8" 6'-8" NEW ADDITION - PORCH 10" ON CENTER AND AT FLOORS. TYPICAL. 4. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET FROM D15 2'-6" 6'-8"3.ROOF SHEATHING PER PLAN AND STUCTURAL GENERAL NOTES. SHEATHING TO BE NAILED6'-8" _______ --- THE DOOR OR OPENING OF A BATHROOM. D16 2'-4" 6'-8"TO ROOF FRAMING WITH 8d X 2 ½6'-8" ” COMMON WIRE NAILS @ 6” OC AT SUPPORTED PANEL ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH D17 1'-8" 6'-8"EDGES, AND 126'-8" ” OC FIELD NAILING. LAY SHEATHING THE LONG DIRECTION PERPENDICULAR DN HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. THE LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER TO SUPPORTS AND STAGGER PANEL END JOINTS. ALLOW 1/8” SPACE BETWEEN PANEL ENDS D18 2'-6" 6'-8" 6'-8" MINIMUM CLEAR OPENING HEIGHT DIMENSION SHALL BE 24". MINIMUM THAN 24". CLEAR OPENING WIDTH DIMENSION SHALL BE 20". SILL HEIGHT SHALL D19 2'-6" 6'-8"AND EDGES.6'-8" NOT BE MORE THAN 44" ABOVE THE FLOOR. ALTERATIONS, REPAIRS AND ADDITIONS R314.2.2 WHERE ALTERATIONS, D20 2'-6" 6'-8" 6'-8" REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHERE ONE OR D21 5'-0" 6'-8"4.ALL 2X HANGERS TO BE TOP FLANGE BEARING SIMPSON JB TYPE, UNLESS NOTED6'-8" SHOWER COMPARTMENTS AND WALLS AROUND BATHTUBS WITH MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DEMO 2'-6" 6'-8"OTHERWISE. ANY HANGERS REQUIRED AT BEAMS ARE SPECIFIED ON PLAN. I JOIST6'-8" SHOWERS SHALL BE FINISHED WITH A SMOOTH NON-ABSORBANT DWELLINGS, OR WHERE AN ACCESSORY DWELLING UNIT IS CREATED DEMO 2'-6" 6'-8"HANGERS TO BE TOP FLANGE BEARING SIMPSON MIT OR ITS TYPE, UNLESS NOTED6'-8" SURFACE TO NOT LESS THAN 72" ABOVE THE FLOOR (IRC R307.2). WITHIN AN EXISTING DWELLING UNIT, EACH DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS AS REQUIRED FOR NEW DWELLINGS. MAIN LEVEL OTHERWISE. ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN D1 3'-0" 6'-8" 6'-8" D2 1 MAIN LEVEL OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM OF 3/4" D2 6'-0" 6'-8"5.BEAMS ARE FLUSH FRAMED WITH JOISTS, UNLESS NOTED OTHERWISE ON DETAILS, OR ON6'-8" 1/4" = 1'-0" ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER DOOR AND TRANSFER GRILLE ABOVE DOOR. HEAT DETECTION INTERCONNECTION R314.4.1 HEAT DETECTORS AND D3 6'-0" 6'-8"PLANS AS 6'-8"“DB.” DB INDICTES A “DROPPED BEAM” WHICH IS FRAMED BELOW THE FLOOR. HEAT ALARMS SHALL BE CONNECTED TO AN ALARM OR A SMOKE ALARM D4 2'-6" 6'-8"WHERE BEAMS ARE NOT SUPPORTED BY HANGERS, SUPPORT IS PER THE STUD AND SHEAR6'-8" PROVIDE WEATHER RESISTANT FIBER CEMENT WALLBOARD UNDER TUB THAT IS INSTALLED IN THE DWELLING. ALARMS THAT ARE INSTALLED FOR D5 2'-8" 6'-8"WALL PLAN. PROVIDE A35 CLIPS EA SIDE OF BEAMS THAT BEAR ON DOUBLE TOP PLATES.6'-8" AND SHOWER ENCLOSURE MATERIALS TO A HEIGHT OF 70" MINIMUM THIS PURPOSE SHALL BE LOCATED IN A HALLWAY, ROOM, OR OTHER D6 2'-6" 6'-8" 6'-8" ABOVE THE DRAIN INLET. LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION. D7 2'-6" 6'-8"6.PROVIDE SIMPSON STRONG TIE H2.5A TIES AT ALL ROOF TRUSSES6'-8" FLOOR PLAN KEY NOTES ARLINGTON, WA D8 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN COMBINATION ALARMS R314.5 COMBINATION SMOKE AND CARBON OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM ? 3/4" MONOXIDE ALARMS MAY BE USED IN PLACE OF SMOKE ALARMS. D9 6'-0" 6'-8"7.WHERE SHEAR WALLS ARE PERPENDUCLAR TO ROOF TRUSSES, PROVIDE 2X BLOCKING6'-8" NO. DESCRIPTION ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D10 5'-0" 6'-8" 6'-8" 1 EXISTING SEWER ~5' ABOVE FFE BETWEEN ROOF TRUSSES WITH SIMPSON STRONG TIE A35 CLIPS @ 24” OC INTO THE DOOR AND TRANSFER GRILLE ABOVE DOOR. POWER SOURCE R314.6 SMOKE ALARMS, HEAT ALARMS, AND HEAT D11 2'-6" 6'-8" 6'-8" 2 EXISTING ELECTRICAL PANEL-150 AMP, UPGRADE TO 200 AMP DETECTORS SHALL RECEIVE PRIMARY POWER FROM THE BUILDING DOUBLE PLATE. WHERE SHEAR WALLS ARE PARALLEL, ALIGN TRUSS OVER SHEAR WALL, D12 5'-0" 6'-8" 6'-8" 1. A CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH WIRING AND, WHEN POWER IS INTERRUPTED, SHALL RECEIVE POWER AND PROVIDE CONNECTION PER SHEAR WALL SCHEDULE. SEPARATE SLEEPING AREA IN IMMEDIATE VICINITY OF BEDROOMS D22 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ADDITION FROM A BATTERY. VIRTUS STAMP AND SCOPE AND ON EACH LEVEL PER 2015 IRC R315. DEMO 2'-0" 6'-8" 6'-8" 8.ALL RIM JOISTS TO BE 1 ½” LSL MINIMUM, UNLESS OTHERWISE NOTED ON PLAN. ENCOMPASSES THE PRIMARY 2. A SMOKE DETECTOR SHALL BE INSTALLED IN EACH HABITABLE ROOM. INTERCONNECTIVITY R314.4 WHERE MORE THAN ONE SMOKE ALARM IS DEMO 2'-4" 6'-8" 6'-8" 3. A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH REQUIRED TO BE INSTALLED, THE ALARM DEVICES SHALL BE DEMO 5'-0" 6'-8" 6'-8" STRUCTURAL ELEMENTS AS SHOWN FLOOR. INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE DEMO 2'-6" 6'-8"9.ADDITIONAL TYPICAL DETAILS NOT CALLED OUT ON PLAN PER SHEET S-4.0. NOT ALL6'-8" IN THE REDLINE MARKUPS, ONLY. 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING DETAILS MAY BE APPLICABLE. DEMO 2'-6" 6'-8" 6'-8" LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL NOT BE PROJECT: SMITH REMODEL PROJECT NUMBER: 24081-0106 THAN 24". REQUIRED WHERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL DEMO 2'-0" 6'-8" 6'-8" 5. SMOKE DETECTORS SHALL BE 110V HARDWIRED, INTERCONNECTED, ALARMS SOUND UPON ACTIVATION OF ONE ALARM. Job No.: 23-15 WITH BATTERY BACKUP, PER 2015 IRC R314. WHERE AN ACCESSORY DWELLING UNIT IS CREATED WITHIN AN EXISTING DATE: 01/16/2025 NOTE: A SPRINKLER SYSTEM IS NOT REQUIRED FOR THIS RESIDENCE. DWELLING UNIT ALL REQUIRED SMOKE ALARMS, IN THE ACCESSORY DWELLING UNIT AND THE PRIMARY DWELLING UNIT, SHALL BE DESCRIPTION: CEILING SOFFIT FRAMING PLAN DRAWN BY: CDA INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL ALARMS IN BOTH THE PRIMARY DWELLING UNIT A2.0 AND THE ACCESSORY DWELLING UNIT _______ - 28'-0 1/2" 8 14'-0 1/4" 14'-0 1/4" 9 1 - 2 3 4 5 6 7 8 9 S-4.2 _______ --- 1 2 3 4 5 6 7 8 H DIM. TO CL OF POST - _______ I --- G (N)GLULAM BEAM ABV. 39'-1 7/8" COVERED PORCH ADDITION (N) FOUNDATION, SEE FDN PLAN 2x10 @ 24" OCVAULTED CEILING 4/12 SLOPE 2x10 @ 24" OC GUARDRAILS REQUIRED IF DECK SURFACE (N) VENTED CRAWLSPACE MORE THAN 30" ABOVE GRADE - _______ --- WINDER REQUIRED 12'-9 1/4" TO MEET HEADROOM (E) FOUNDATION, SEE FDN PLAN PER CODE-6'-8" MIN. 13'-9 1/4" 14'-3 1/4" NEW ADDITION 9'-4 3/4" 4'-4 1/2" 2'-7 1/4" 4'-7" 4'-7" 2'-6" 4'-1" F (DROPPED) DIM. TO F2 F1 GL 5 1/2" x 10 1/2" FACE OF DIM. TO CONC. 10'-0 3/8" 2'-5 1/2" 6'-8 1/2" 9'-3 3/8" 9'-8 1/8" FACE OF (DROPPED)9'-4 3/4" 4'-4 1/2" D2 CONC. E GL 5 1/2" x 10 1/2" H (E) VENTED CRAWLSPACE W4 F5 F4 F3 - _______ 3'-0" --- W4 - 4'-0" 2 NEW ADDITION _______ --- = W5 D13 (N) BATH 12 G 4'-3" (N) BEDROOM 3 3'-2 3/4"D21 3'-6" 5'-10 1/4" DW S-4.0DN CL. (N) STORAGE 5'-9 1/2" (N) DINING TYPICAL AT NEW EGRESS REMOVE WINDOW CONSTRUCTION, UNLESS D3 9'-0 1/2" F23 = AND FILL IN WITH NOTED OTHERWISE 11'-4 1/2" FRAMING ALIGN NEW FRAMING CONVERT TO EGRESS WINDOW STAIRS: W4 GL 5 1/2" x 10 1/2" RIDGE BEAMTO CORNER (E) WALL SILL AT +44" A.F.F. MAX. 14RISERS 3'-9 3/4" (N) KITCHEN AT 7" 2X4 INTERIOR WALL, TYP. VAULTED CEILING 4/12 SLOPE 6 REMOVE SIDING 13'-3 7/8" WH 1/2" AIR GAP FROM CONCRETE ON EXT. WALL 5'-6 1/4" S LINEN S 12'-0" 2'-0" S-4.0 W3 F22 13'-0 1/8" STAIR OPENING Range D18 D17 D16 5'-10" 3'-6 5/8" 7'-8 3/8" FULL HEIGHT WALL F 3'-10" D19 D15 STUB FOR 6'-4 7/8" S/CM 7'-9 1/8" STAIR OPENING FUTURE SINK 1 (E) WIN. COULD REMAIN 24'-0" 3'-11 5/8" GRINDER (N) MECH. 2'-9 7/8" PUMP STORAGE CL VANITY ABV. ISLAND 10' X 5' S PANTRY (E) MASTER BEDROOM CLOSET 7'-10 1/8" D DBL OvenOVEN E 28'-0" ALIGN 8'-1 1/4" D14 CL TOILET ABV. 3'-6 5/8" ALIGN WALL ON CENTER W/POST - FLUSH INSIDE FACE OF WALL _______ 9'-0 5/8" 28'-0" EXISTING BASEMENT OF POST 7'-2" --- (N) SKYLIGHT OVER THE STAIRS TO INSIDE FACE OF BEAM (N)GLULAM 2'-0" C BEAM ABV. 6'-0" Refrigerator (E) DOOR OPENING CL SHOWER DRAIN ABV. ALTER AS NEEDED PER DOOR CL VANITY ABV. 8'-10 1/8" W3 LOCATE WITHIN 3' OF PEAK D9 SELECTION F21 F24 W5 D20 CL WASHER ABV. GL 5 1/2" x 10 1/2" EGRESS Copyright 2020 Sno Valley Cottages, LLC All rights reserved. (N)6X6 POST-BEARING TO CABINETS/COUNTER 3'-3 1/2" 2'-10 1/4" 4'-0 1/8" 2'-4" 2'-6" (N) OFFICE (N) BONUS ROOM (DROPPED) 4'-0" F6 (N) WALL BELOW TO FTG. 6'-1 3/8" W1 No. Date 9'-4 3/4" F25 2'-1 1/2" CL TOILET ABV. 3'-4 1/2" S 10 (N) BATHROOM 13'-6" TO CL OF (E) BEAM AND POSTS D8 CL. = B S-4.0MATCH CL PLUMBING WALL ABV. DIM. TO = D10 CL SHOWER DRAIN ABV. 2'-11" WALL AT +42" A.F.F. D7 FACE OF 15'-8 1/2" (E) 2x4 @ 24" OC 5'-11 1/4" W6 66" VANITY 4'-0" CONC. DN 4'-9" = 5'-4" 15'-11 1/4" TO STAIR OPENING CLOSET 3'-10 7/8" 1'-4" MIRROR DIM. ON FIREPLACE CENTER 7'-9 1/8" = CONFIRM RO WITH POCKET DOOR SPECS (2)2X NOT FOR CONSTRUCTIONFIREPLACE D11 3 1/2" D 3'-3 1/2" SHOWER/TOILET A MATCH (N) GREAT ROOM = FLAT CEILING AT 7' 10-3/4" EXISTING RESIDENCE F20 4'-0" 2'-0" MIRROR DIM. ON FIREPLACE CENTER REBUILD FP AT INTERIOR (N)6x6 POST-BEARING TO METAL RAILING 3'-1" 3'-8 1/4"S/CM SHOWER 4'-3 1/2" F7 AT +36" A.F.F. 4' W X 3' D = Issue Date TO CENTER BEAM BELOW C - ON BEAMS ABV. AND STAIRGL 5 1/2" x 10 1/2" D4 D5 _______ --- (DROPPED) S ADD 2' X 2' SKYLIGHT ABOVE F8 7'-6" 9'-0 1/2" 30'-1 3/8" 10 W1 (N) GLULAM BEAM ABV. 42" VANITY 4'-9 7/8" S-4.0 6'-0" (N) BEDROOM 2 F19 Author F9 4'-2 1/2"4'-2 1/2" 3'-4 1/2"(N) BATH W2 1'-0" Drawn by: D12 5'-0" (E) 2x4 @ 24" OC BENCH/CUBBIES/CABS 9'-7 5/8" B 2 BASEMENT LEVEL 7'-6" W3 F18 1/4" = 1'-0" 6'-2 7/8" 1'-4 3/8"1'-4 3/8" CLOSET F10 F11 F12 1'-3 1/2" 4'-5 1/2"2'-10" 2'-2" 2'-4 1/2" 6'-7 7/8" 6'-7 7/8" 4'-9 7/8" REMODEL/ADDITION FLOOR PLANS 3'-1 3/8" EGRESS Scale: FLOOR PLAN NOTES D1 As indicated SMOKE ALARMS AND HEAT DETECTION A FRAMING: 2X6 EXTERIOR WALLS REQUIRED LOCATIONS R314.3: FRAMING - DOOR SCH. 1'-6" 3'-0" 7'-6" SMOKE ALARMS/CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN: 2X4/6's AT INTERIOR WALLS UNLESS NOTED OTHERWISE 1. IN EACH SLEEPING ROOM OR SLEEPING LOFT NO. DOOR SIZE HEAD HEIGHT COMMENTS F13 F14 F15 F16 F17 FILL IN 2X4 FRAMING 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE BASEMENT FF AT ALL MODIFIED SEE STRUCTURAL NOTES FOR STUD SCHEDULE. VICINITY OF THE BEDROOMS. D13 2'-6" 6'-8" 6'-8" COVERED WINDOW OPENINGS 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING ROOF FRAMING PLAN NOTES: CONCEALED SPACES SHALL BE FIRESTOPPED IN BOTH DIRECTIONS AT BASEMENTS AND HABITABLE ATTICS. D14 2'-10" 6'-8" 6'-8" NEW ADDITION - PORCH 1.STRUCTURAL GENERAL NOTES, DESIGN CRITERIA, ABBREVIATIONS AND LEGEND PER S-1.0,_______ 10" ON CENTER AND AT FLOORS. TYPICAL. 4. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET FROM D15 2'-6" 6'-8" 6'-8" --- THE DOOR OR OPENING OF A BATHROOM. D16 2'-4" 6'-8"S-1.1, AND S-1.2.6'-8" ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH D17 1'-8" 6'-8" 6'-8" DN HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. THE LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER 2.ALL DUCTS CHASES AND PIPES SHALL BE PER MECHANICAL, PLUMBING, ELECTRICAL AND D18 2'-6" 6'-8" 6'-8" MINIMUM CLEAR OPENING HEIGHT DIMENSION SHALL BE 24". MINIMUM THAN 24". CLEAR OPENING WIDTH DIMENSION SHALL BE 20". SILL HEIGHT SHALL D19 2'-6" 6'-8"SPRINKLER DRAWINGS. 6'-8" NOT BE MORE THAN 44" ABOVE THE FLOOR. ALTERATIONS, REPAIRS AND ADDITIONS R314.2.2 WHERE ALTERATIONS, D20 2'-6" 6'-8" 6'-8" REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHERE ONE OR D21 5'-0" 6'-8"3.ROOF SHEATHING PER PLAN AND STUCTURAL GENERAL NOTES. SHEATHING TO BE NAILED6'-8" SHOWER COMPARTMENTS AND WALLS AROUND BATHTUBS WITH MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DEMO 2'-6" 6'-8"TO ROOF FRAMING WITH 8d X 2 ½6'-8" ” COMMON WIRE NAILS @ 6” OC AT SUPPORTED PANEL SHOWERS SHALL BE FINISHED WITH A SMOOTH NON-ABSORBANT DWELLINGS, OR WHERE AN ACCESSORY DWELLING UNIT IS CREATED SURFACE TO NOT LESS THAN 72" ABOVE THE FLOOR (IRC R307.2). WITHIN AN EXISTING DWELLING UNIT, EACH DWELLING UNIT SHALL BE DEMO 2'-6" 6'-8"EDGES, AND 126'-8" ” OC FIELD NAILING. LAY SHEATHING THE LONG DIRECTION PERPENDICULAR EQUIPPED WITH SMOKE ALARMS AS REQUIRED FOR NEW DWELLINGS. MAIN LEVELTO SUPPORTS AND STAGGER PANEL END JOINTS. ALLOW 1/8” SPACE BETWEEN PANEL ENDS ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN D1 3'-0" 6'-8"AND EDGES.6'-8" D2 1 MAIN LEVEL OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM OF 3/4" D2 6'-0" 6'-8" 6'-8" 1/4" = 1'-0" ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D3 6'-0" 6'-8"4.ALL 2X HANGERS TO BE TOP FLANGE BEARING SIMPSON JB TYPE, UNLESS NOTED6'-8" DOOR AND TRANSFER GRILLE ABOVE DOOR. HEAT DETECTION INTERCONNECTION R314.4.1 HEAT DETECTORS AND HEAT ALARMS SHALL BE CONNECTED TO AN ALARM OR A SMOKE ALARM D4 2'-6" 6'-8"OTHERWISE. ANY HANGERS REQUIRED AT BEAMS ARE SPECIFIED ON PLAN. I JOIST6'-8" PROVIDE WEATHER RESISTANT FIBER CEMENT WALLBOARD UNDER TUB THAT IS INSTALLED IN THE DWELLING. ALARMS THAT ARE INSTALLED FOR D5 2'-8" 6'-8"HANGERS TO BE TOP FLANGE BEARING SIMPSON MIT OR ITS TYPE, UNLESS NOTED6'-8" AND SHOWER ENCLOSURE MATERIALS TO A HEIGHT OF 70" MINIMUM THIS PURPOSE SHALL BE LOCATED IN A HALLWAY, ROOM, OR OTHER D6 2'-6" 6'-8" 6'-8" ABOVE THE DRAIN INLET. LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION. OTHERWISE. D7 2'-6" 6'-8" 6'-8" FLOOR PLAN KEY NOTES ARLINGTON, WA D8 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ALL BEDROOM DOORS, AND BATHROOM DOORS IN BATHROOMS WITH AN COMBINATION ALARMS R314.5 COMBINATION SMOKE AND CARBON 5.BEAMS ARE FLUSH FRAMED WITH JOISTS, UNLESS NOTED OTHERWISE ON DETAILS, OR ON OCCUPANCY VENTILATION FAN SHALL BE UNDERCUT A MINIMUM ? 3/4" MONOXIDE ALARMS MAY BE USED IN PLACE OF SMOKE ALARMS. D9 6'-0" 6'-8" 6'-8" NO. DESCRIPTION PLANS AS “DB.” DB INDICTES A “DROPPED BEAM” WHICH IS FRAMED BELOW THE FLOOR. ABOVE THE ADJACENT FLOOR COVERING OR PROVIDE SWEEP UNDER D10 5'-0" 6'-8" 6'-8" 1 EXISTING SEWER ~5' ABOVE FFE DOOR AND TRANSFER GRILLE ABOVE DOOR. POWER SOURCE R314.6 SMOKE ALARMS, HEAT ALARMS, AND HEAT D11 2'-6" 6'-8"WHERE BEAMS ARE NOT SUPPORTED BY HANGERS, SUPPORT IS PER THE STUD AND SHEAR6'-8" 2 EXISTING ELECTRICAL PANEL-150 AMP, UPGRADE TO 200 AMP DETECTORS SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WALL PLAN. PROVIDE A35 CLIPS EA SIDE OF BEAMS THAT BEAR ON DOUBLE TOP PLATES. D12 5'-0" 6'-8" 6'-8" 1. A CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH WIRING AND, WHEN POWER IS INTERRUPTED, SHALL RECEIVE POWER SEPARATE SLEEPING AREA IN IMMEDIATE VICINITY OF BEDROOMS D22 2'-6" 6'-8" 6'-8" 309 S DUNHAM AVE ADDITION FROM A BATTERY. 6.PROVIDE SIMPSON STRONG TIE H2.5A TIES AT ALL ROOF TRUSSES VIRTUS STAMP AND SCOPE AND ON EACH LEVEL PER 2015 IRC R315. DEMO 2'-0" 6'-8" 6'-8" ENCOMPASSES THE PRIMARY 2. A SMOKE DETECTOR SHALL BE INSTALLED IN EACH HABITABLE ROOM. INTERCONNECTIVITY R314.4 WHERE MORE THAN ONE SMOKE ALARM IS DEMO 2'-4" 6'-8" 6'-8" 3. A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH REQUIRED TO BE INSTALLED, THE ALARM DEVICES SHALL BE DEMO 5'-0" 6'-8"7.WHERE SHEAR WALLS ARE PERPENDUCLAR TO ROOF TRUSSES, PROVIDE 2X BLOCKING6'-8" STRUCTURAL ELEMENTS AS SHOWN FLOOR. INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE DEMO 2'-6" 6'-8"BETWEEN ROOF TRUSSES WITH SIMPSON STRONG TIE A35 CLIPS @ 246'-8" ” OC INTO THE IN THE REDLINE MARKUPS, ONLY. 4. AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING DOUBLE PLATE. WHERE SHEAR WALLS ARE PARALLEL, ALIGN TRUSS OVER SHEAR WALL, DEMO 2'-6" 6'-8" 6'-8" LOCATION WHERE THERE IS A CEILING HEIGHT CHANGE GREATER UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL NOT BE PROJECT: SMITH REMODEL PROJECT NUMBER: 24081-0106 THAN 24". REQUIRED WHERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL DEMO 2'-0" 6'-8"AND PROVIDE CONNECTION PER SHEAR WALL SCHEDULE.6'-8" 5. SMOKE DETECTORS SHALL BE 110V HARDWIRED, INTERCONNECTED, ALARMS SOUND UPON ACTIVATION OF ONE ALARM. Job No.: 23-15 WITH BATTERY BACKUP, PER 2015 IRC R314. WHERE AN ACCESSORY DWELLING UNIT IS CREATED WITHIN AN EXISTING 8.ALL RIM JOISTS TO BE 1 ½” LSL MINIMUM, UNLESS OTHERWISE NOTED ON PLAN. DATE: 01/16/2025 NOTE: A SPRINKLER SYSTEM IS NOT REQUIRED FOR THIS RESIDENCE. DWELLING UNIT ALL REQUIRED SMOKE ALARMS, IN THE ACCESSORY DWELLING UNIT AND THE PRIMARY DWELLING UNIT, SHALL BE 9.ADDITIONAL TYPICAL DETAILS NOT CALLED OUT ON PLAN PER SHEET S-4.0. NOT ALL DESCRIPTION: ROOF FRAMING PLAN DRAWN BY: CDA INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL ALARMS IN BOTH THE PRIMARY DWELLING UNIT DETAILS MAY BE APPLICABLE. A2.0 AND THE ACCESSORY DWELLING UNIT GENERAL REQUIREMENTS STRUCTURAL OBSERVATION FILL MATERIAL PENETRATION SLEEVES STRUCTURAL OBSERVATION IS THE VISUAL OBSERVATION OF THE STRUCTURAL COMPACTED FILL MATERIAL SHALL BE PLACED IN MAXIMUM 12" LIFTS AND PROVIDE SLEEVES FOR ALL UTILITY OPENINGS. DO NOT CUT ANY REINFORCING GOVERNING CODE SYSTEM BY A REGISTERED DESIGN PROFESSIONAL FOR GENERAL SHALL BE COMPACTED TO MINIMUM 95% MODIFIED PROCTOR IN ACCORDANCE AT OPENINGS. CONCRETE WHICH HAS CONTAINED WATER FOR MORE THAN 90 THE DESIGN AND CONSTRUCTION OF THIS PROJECT IS GOVERNED BY THE CONFORMANCE TO THE APPROVED CONSTRUCTION DOCUMENTS. PER IBC WITH ASTM D1557. COMPACTION SHALL BE VERIFIED BY A QUALIFIED MINUTES (60 MINUTES IF AIR TEMPERATURE EXCEEDS 85 DEGREES) SHALL NOT INTERNATIONAL BUILDING CODE (IBC) 2021 EDITION, HEREAFTER REFERRED SECTION 1704.6 STRUCTURAL OBSERVATION IS NOT REQUIRED FOR THIS INSPECTOR APPROVED BY THE BUILDING OFFICIAL. BE USED. RETEMPERING OF CONCRETE AFTER INITIAL SET IS NOT ALLOWED. TO AS THE IBC, AS ADOPTED AND MODIFIED BY ARLINGTON, WA UNDERSTOOD PROJECT. HOWEVER, THIS DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY CURE EXPOSED CONCRETE PER ACI 301 FOR A MINIMUM OF 7 DAYS. FOR THE SPECIAL INSPECTIONS AND TESTS REQUIRED BY A SPECIAL INSPECTOR TO BE THE AUTHORITY HAVING JURISDICTION (AHJ). DRAINAGE PER IBC CHAPTER 17. PROVIDE POSITIVE DRAINAGE SLOPES, BOTH DURING AND AFTER CONSTRUCTION JOINTS REFERENCE STANDARDS CONSTRUCTION, FOR SURFACE AND ROOF RUNOFF. CONFORM TO ACI301 SECTION 2.2.2.5, 5.2.2.1, AND 5.3.2.6. SUBMIT LOCATIONS OF AT THE ENGINEERS DISCRETION, SITE OBSERVATIONS MAY STILL BE REFER TO CHAPTER 35 OF THE IBC. WHERE OTHER STANDARDS ARE NOTED IN CONSTRUCTION JOINTS PER ACI301 SECTION 5.1.2.3a FOR REVIEW AND APPROVAL PERFORMED. ONLY SIGNIFICANT STAGES OF CONSTRUCTION IDENTIFIED BY THE THE DRAWINGS, USE THE LATEST EDITION OF THE STANDARD UNLESS A BASEMENT WALLS BY THE STRUCTURAL ENGINEER OF RECORD TWO WEEKS MINIMUM PRIOR TO STRUCTURAL OBSERVER REQUIRE OBSERVATION. FOR REPETITIVE OR SIMILAR SPECIFIC DATE IS INDICATED. REFERENCE TO A SPECIFIC SECTION IN A CODE FORMING. STRUCTURAL ELEMENTS IDENTIFIED AS SIGNIFICANT, ONLY THE FIRST ELEMENT DO NOT BACKFILL AGAINST BASEMENT OR RESTRAINED WALLS UNTIL FRAMING DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE ENTIRE OF A STAGE REQUIRES OBSERVATION UNLESS NOTED OTHERWISE. TO SUPPORT WALL IS PERMANENTLY ATTACHED. DO NOT EXCEED 1'-0" STANDARD. DIFFERENTIAL IN FILL LEVEL ON OPPOSITE SIDES OF FOUNDATION WALLS. EMBEDDED ITEMS POSITION AND SECURE IN PLACE EXPANSION JOINT MATERIAL, ANCHORS AND CONSTRUCTION DOCUMENTS THE STRUCTURAL CONSTRUCTION DOCUMENTS REPRESENT THE FINISHED DESIGN CRITERIA DIVISION OF RESPONSIBILITY OTHER STRUCTURAL AND NON STRUCTURAL EMBEDDED ITEMS BEFORE PLACING CONCRETE. CONTRACTOR SHALL REFER TO MECHANICAL, STRUCTURE. THEY DO NOT INDICATE THE METHOD OR SEQUENCE OF THE STRUCTURAL ENGINEER IS NOT RESPONSIBLE FOR ANY GEOTECHNICAL ELECTRICAL, PLUMBING AND ARCHITECTURAL DRAWINGS AND COORDINATE CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND PROVIDE 1. BUILDING RISK CATEGORY II. ASPECTS OF THIS PROJECT. IT IS RECOMMENDED THAT THE OWNER RETAIN A OTHER EMBEDDED ITEMS. ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING REGISTERED GEOTECHNICAL ENGINEER TO CONDUCT A GEOTECHNICAL CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, 2. FLOOR LIVE LOAD = 40 PSF (REDUCIBLE). INVESTIGATION AND PREPARE A REPORT WITH RECOMMENDATIONS FOR BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. THE FOUNDATION DESIGN AND EARTHWORK PROCEDURES. GROUT STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S USE 7000 PSI NOON SHRINK GROUT UNDER COLUMN BASE PLATES. 3. ROOF LIVE LOAD = 20 PSF MEANS, METHODS, TECHNIQUES, SEQUENCES FOR PROCEDURE OF EXTERIOR SLABS AND SIDEWALKS CONSTRUCTION, OR THE SAFETY PRECAUTIONS AND THE PROGRAMS INCIDENT SEE ARCHITECTURAL/CIVIL DRAWINGS FOR EXTERIOR SLABS AND SIDEWALKS. BONDING AGENT THERETO (NOR SHALL OBSERVATION VISITS TO THE SITE INCLUDE INSPECTION 4.SUPERIMPOSED DEAD LOAD ON ROOF JOISTS = 20 PSF USE MATEREMACO ADH326. APPLY IN ACCORDANCE WITH MANUFACTURER OF THESE ITEMS). THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN INSTRUCTIONS. AND IMPLEMENTATION OF ALL SCAFFOLDING, BRACING AND SHORING. 5. GROUND SNOW LOAD = 25 PSF, Ce=1.0, Is=1.0, Ct=1.2, C = 1.0 FLAT ROOF SNOW S LOAD = 21 PSF. SLOPED ROOF SNOW LOAD = 21 PSF CONCRETE CONSTRUCTION MATERIAL STORAGE CONCRETE CRACK REPAIR AND MAINTENANCE PROGRAM CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONCRETE SHRINKS AND CONTINUES TO SHRINK FOR UP TO TWO YEARS AFTER 6. ULTIMATE WIND SPEED = 98 MPH (3-SECOND GUST), RISK CATEGORY II, STANDARDS CONSTRUCTION. LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE CONSTRUCTION AND AS A RESULT, CRACKING WILL TYPICALLY OCCUR. THESE FOOT. EXPOSURE C, GCpi=+/-0.55, Ke = 0.99, G = 0.85, Kzt = 1.0 ACI301-10 “SPECIFICATION FOR STRUCTURAL CONCRETE” CRACKS TO NOT TYPICALLY IMPAIR THE INTEGRITY OF THE STRUCTURE. IBC CHAPTER 19 “CONCRETE” HOWEVER, VIRTUS RECOMMENDS A ONE-TIME CRACK REPAIR AND CONTRACTOR OPTIONS COMPONENT AND CLADDING PRESSURES: ACI318-19 “BUILDING CODE REQUIREMENT FOR STRUCTURAL CONCRETE” MAINTENANCE PROGRAM BE IMPLEMENTED FOR THOSE SLABS EXPOSED TO OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS CHOSEN, THE ACI117-10 “SPECIFICATIONS FOR TOLERANCE FOR CONCRETE CONSTRUCTION WATER OR CHEMICALS. THE MAINTENANCE PROGRAM SHALL CONSIST OF: CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES AND AND MATERIALS” · INSPECT SLABS AND SUPPORTING MEMBERS TWO YEARS AFTER SHALL COORDINATE ALL DETAILS WITH ALL TRADES. CONSTRUCTION MIX DESIGN: · DETERMINE CRACKS IN THE STRUCTURE TO BE REPAIRED NOTE PRIORITIES · REPAIR CRACKS NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. FOR THE TOTAL LENGTH OF CRACKING CAN BE ESTIMATE AT 0.009 FEET OF CRACKS BIDDING PURPOSES, WHERE ANY MEMBER IS SHOWN BUT NOT CALLED OUT, THE PER SQUARE FEET OF SLAB AREA. THE OWNER SHOULD RESERVE FUNDS FOR LARGEST SIMILAR MEMBER SHALL BE UTILIZED. THIS ONE TIME MAINTENANCE PROGRAM, WHICH IS TO TAKE PLACE TWO YEARS AFTER THE COMPLETION OF CONSTRUCTION. DIMENSIONS THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL EVEN THOUGH CRACKING IS NORMAL AND MOST OFTEN NOT STRUCTURAL DIMENSIONS WITH ARCHITECTURAL OR HOME DESIGNER DRAWINGS PRIOR TO SIGNIFICANT, WHEN CRACKING OCCURS DURING CONSTRUCTION THE START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ARCHITECT CONTRACTOR SHALL CONTAC THE ARCHITECT/ENGINEER FOR REVIEW. THE OR ENGINEER OF RECORD. DO NOT USE SCALED DIMENSIONS. CONTRACTOR SHOULD BUDGET 0.004 FT OF EPOXY INJECTED CRACK REPAIR PER 309 S DUNHAM AVE SQUARE FOOT OF SLAB. ARLINGTON, WA 98223 DETAIL CALLOUTS ALL DETAILS SHALL BE INCORPORATED INTO THE PROJECT AT ALL STRENGTH TESTING AND ACCEPTANCE APPROPRIATE LOCATIONS, WHETHER SPECIFICALLY CUT OR NOT. TYPICAL NOTES ON MIX DESIGN TABLE TESTING: OBTAIN SAMPLES AND CONDUCT TESTS IN ACCORDANCE WITH ACI301 DETAILS MAY NOT NECESSARILY BE CUT ON PLANS, BUT APPLY UNLESS NOTED 1. CONFORM TO ACI 301 SECTION 4, AND 4.2.1. SECTION 1.6.3.2. ADDITIONAL SAMPLES MAY BE REQUIRED TO OBTAIN OTHERWISE. FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING 2. W/C RATIO SHALL BE BASED ON THE TOTAL WEIGHT OF CEMENTITIOUS CONCRETE STRENGTHS AT ALTERNATE INTERVALS THAN SHOWN BELOW: CONDITION. MATERIALS. MAXIMUM RATIOS ARE CONTROLLED BY STRENGTH NOTED IN TH ETABLE ABOVE, AND DURABILITY REQUIREMENTS IN ACI318 SECTION 19.3. DRAWING DISCREPANCIES CURE (4) CYLINDERS FOR 28-DAY TEST AGE. TEST (1) CYLINDER AT 7 DAYS, TEST 3. CEMENTITIOUS MATERIALS: WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL 2 CYLINDERS AT 28 DAYS AND HOLD 1 CYLINDER IN RESERVE FOR USE AS THE STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS a. THE USE OF FLY ASH, OTHER POZZOLANS, SILICA FUME, OR SLAG SHALL ENGINEER DIRECTS. AFTER 56 DAYS UNLESS NOTIFIED BY THE ENGINEER TO THE SHALL GOVERN. CONFORM TO ACI318 SECTIONS 1903.2 AND 26.4.2.2. MAXIMUM AMOUNT CONTRARY, THE RESERVE CYLINDER MAY BE DISCARDED WITHOUT BEING SMITH REMODEL OF FLY ASH SHALL BE 25% OF TOTAL CEMENTITIOUS CONTENT UNLESS TESTED FOR SPECIMENS MEETING 28-DAY STRENGTH REQUIREMENTS. REVIEWED AND APPROVED OTHERWISE BY STRUCTURAL ENGINEER OF SPECIALTY ENGINEERING RECORD. ANY ENGINEERING DESIGN, PROVIDED BY OTHERS AND SUBMITTED FOR THE NUMBER OF CYLINDERS INDICATED ABOVE REFERENCE 6 BY 12 INCH b.CEMENTITIOUS MATERIALS SHALL CONFORM TO THE RELEVANT ASTM REVIEW, SHALL BEAR THE SEAL OF AN ENGINEER REGISTERED IN THE STATE OF CYLINDER. IF 4 BY 8 CYLINDERS ARE TO BE USED, ADDITIONAL CYLINDERS STANDARDS LISTED IN ACI318 SECTION 26.4.1.1.1 (a). WASHINGTON. THIS IS TO INCLUDE, BUT NOT BE LIMITED TO BRACING AND 7.SEISMIC DESIGN CATEGORY D, SOILS SITE CLASS D, RISK CATEGORY II, Ie=1.0, MUST BE CURED FOR TESTING OF 3 CYLINDERS AT TEST AGE PER THE TABLE OF SHORING WHETHER TEMPORARY OR PERMANENT. 4. AIR CONTENT TO CONFORM TO ACI318 SECTION 19.3.3.1. MINIMUM MIX DESIGN REQUIREMENTS. Ss=1.034g, S1=0.369g, SDs=0.749g STANDARDS FOR EXPOSURE CLASS ARE NOTED IN THE TABLE ABOVE. IF OTHER DRAWINGS FREEZING AND THAWING CLASS IS NOT NOTED, AIR CONTENT GIEN IS THAT ACCEPTANCE: STRENGTH IS SATISFACTORY WHEN THE FOLLOWING CONDITIONS REFER TO THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, CIVIL AND REQUIRED BY THE STRUCTURAL ENGINEER OR RECORD. TOLERANCE IS +/- 1 ARE MET: PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION INCLUDING BUT NOT SOILS AND FOUNDATIONS 1/2%. AIR CONTENT SHALL BE MEASURED AT POINT OF PLACEMENT. · THE AVERAGE OF ALL SETS OF 3 CONSECUTIVE TESTS EQUAL OR EXCEED LIMITED TO: DIMENSIONS, ELEVATIONS, SLOPES, DOOR AND WINDOW OPENINGS, 5. AGGREGATES SHALL CONFORM TO ASTM C33 THE SPECIFIED STRENGTH. NON-BEARING WALLS, STAIRS, FINISHES, DRAINS, WATERPROOFING, RAILINGS, 6.SLUMP: CONFORM TO ACI 301 SECTION 4.2.2.2. SLUMP SHALL BE DETERMINED CURBS DEPRESSIONS, MECHANICAL UNIT LOCATIONS, AND OTHER SOILS REPORT · NO INDIVIDUAL TEST FALLS BELOW THE SPECIFIED STRENGTH BY MORE AT POINT OF PLACEMENT. NO SOILS REPORT WAS PROVIDED FOR THIS PROJECT. CONFORM TO IBC THAN 500 PSI. NONSTRUCTURAL ITEMS. 7. CHLORIDE CONTENT: CONFORM TO ACI318 TABLE 19.3.2.1 CHAPTER 18. THE FOLLOWING DESIGN SOIL VALUES HAVE BEEN ASSUMED IN DESIGN OF THESE DOCUMENTS. SPREAD FOOTINGS SHALL BEAR ON COMPETENT 8. EXPOSURE CLASS IS ASSUMED TO BE F0, S0, W0, AND C0 UNLESS DIFFERENT COORDINATION EXPOSURE IS INDICATED IN THE ABOVE TABLE. CONCRETE PLACEMENT TOLERANCE PERMIT 01/16/2025 NATIVE SOIL OR COMPACTED FILL MATERIAL. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING DETAILS AND CONFORM TO ACI117-10 FOR CONCRETE PLACEMENT TOLERANCE. ACCURACY OF THE WORK; FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR DESIGN SOIL VALUES FLY ASH TECHNIQUES OF ASSEMBLY, AND FOR PERFORMING WORK IN A SAFE AND ALLOWABLE FOUNDATION BEARING PRESSURE 1500 PSF (TOTAL LOAD) NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK OR ARCHITECTURALLY SECURE MANNER. ACTIVE LATERAL PRESSURE 45 PSF/FT EXPOSED CONCRETE. FLY ASH (IF PERMITTED BY ARCHITECTURAL REINFORCING STEEL SPECIFICATIONS) SHALL CONFORM TO ASTM C618, CLASS F AND SHALL BE STANDARDS AT REST RESISTING PRESSURE 250 PSF/FT MEANS METHODS AND SAFETY REQUIREMENTS LIMITED TO 18% OF CEMENTITIOUS MATERIALS AND SHALL HAVE A COEFFICIENT OF FRICTION 0.3 ACI 301-10 “STANDARD SPECIFICATION FOR STRUCTURAL CONCRETE.” THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. CONCRETE SECTION 3 “REINFORCEMENT AND REINFORCEMENT SUPPORTS” CONSTRUCTION AND ALL JOB RELATED SAFETY STANDARDS SUCH AS OSHA. FACTOR OF SAFETY 1.5 SHALL BE FREE OF CHLORIDE. MAXIMUM SLUMP 4 1/2" FOR CONCRETE WITHOUT ACI SP-66(04) “ACI DETAILING MANUAL” THE CONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS OF *IT IS ASSUMED THAT ALL WORK IS PERFORMED ABOVE THE GROUND WATER PLASTICIZER. IF PLASTICIZER IS USED, AN 8" MAXIMUM SLUMP IS ALLOWED AT TH CONSTRUCTION RELATED TO THE INTERMEDIATE STRUCTURAL CONDITIONS. TABLE. PLACEMENT. ALL MIX DESIGNS SHALL BE DESIGNED BY THE CONCRETE CRSE MSP-09 28 EDITION “MANUAL OF STANDARD PRACTICE” PRODUCTION FACILITY IN ACCORDANCE WITH ACI 301 AND SHALL BE REVIEWED IBC CHAPTER 19 “CONCRETE” ALTERNATES FROST DEPTH BY THE STRUCTURAL ENGINEER PRIOR TO PLACEMENT. MIX DESIGNS FOR ACI 318-14 “BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE” ALTERNATE PRODUCTS OF SIMILAR STRENGTH, NATURE, AND FORM FOR FOOTINGS SHALL, AT A MINIMUM, EXTEND BELOW THE ESTABLISHED FROST POST-TENSIONING CONCRETE SHALL BE PROPORTIONED SO AS TO MINIMIZE ACI 117-10 “SPECIFICATIONS FOR TOLERANCES FOR CONCRETE SPECIFIED ITEMS MAY BE SUBMITTED WITH ADEQUATE TECHNICAL DEPTH OF 24”. INTERIOR FOOTINGS, FOOTINGS THAT DO NOT SUPPORT A WALL SHRINKAGE CRACKING. CONSTRUCTION AND MATERIALS” DOCUMENTATION TO THE ARCHITECT/ENGINEER FOR REVIEW. ALTERNATE EXPOSED TO THE EXTERIOR, OR WITHIN 3 FEET OF SUCH A WALL, NEED ONLY MATERIALS THAT ARE SUBMITTED WITHOUT ADEQUATE TECHNICAL EXTEND 12” BELOW THE FINISHED GRADE. VIBRATION DOCUMENTATION OR THAT SIGNIFICANTLY DEVIATE FROM THE DESIGN INTENT MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS OF MATERIALS SPECIFIED MAY BE RETURNED WITHOUT A REVIEW. MATERIALS ON GRADE NEED BE VIBRATED ONLY AROUND UNDER-FLOOR DUCTS, ETC. DO ALTERNATES THAT REQUIRE SUBSTANTIAL EFFORT TO REVIEW WILL NOT BE REINFORCING BARS ASTM A615 GRADE 60 DEFORMED BARS NOT DROP CONCRETE MORE THAN FIVE FEET WITH OUT THE USE OF TREMIES. REVIEWED UNLESS AUTHORIZED BY THE OWNER. REVIBRATE TOPS OF CAISSONS 15 MINUTES AFTER PLACING CONCRETE. BAR SUPPORTS CRSI MSP-09 CHAPTER 3 (BAR SUPPORTS) 24081-0106 TIE WIRE 16 GAGE OR HEAVIER, BLACK ANNEALED CONTROL JOINTS HEADED DEFORMED BARS ASTM A970 S-1.0 01/16/2025 UNLESS APPROVED OTHERWISE IN WRITING BY THE ARCHITECT, ALL CONCRETE GENERAL SLABS ON GRADE SHALL BE BOUND BY CONTROL JOINTS (KEYED OR SAW CUT). NOTES NTS KEYED CONTROL JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING POURING, ALL OTHER JOINTS MAY BE SAW CUT. PLACEMENT STRUCTURAL STEEL PROTECTIVE COATING REQUIREMENTS SHEATHING ACCURATELY PLACE OR SUPPORT ALL REINFORCING, INCLUDING WELDED WIRE SHOP PAINTING SHALL CONFORM TO AISC 360 SECTION M3 AND AISC 303 SECTION WOOD APA-RATED STRUCTURAL SHEATHING INCLUDES ALL VENEER PLYWOOD, STANDARDS FABRIC, WITH GALVANIZED METAL CHAIRS. CONFORM TO ACI 301 SECTION 3.3.2. 6.5 UNLESS OTHERWISE SPECIFIED BY THE PROJECT SPECIFICATIONS. WAFER-BOARD, PARTICLEBOARD, T1-11 SIDING, AND COMPOSITES OF VENEER IBC CHAPTER 22 “STEEL” SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. AND WOOD BASED MATERIAL WITH TONGUE AND GROOVE JOINT. PER ANSI/AISC 303-10 “CODE OF STANDARD PRACTICE FOR STEEL BUILDING AND INTERIOR STEEL NEED NOT BE PAINTED IF THE STEEL SURFACES MEET ANY OF ARCHITECTURAL AND OWNER DIRECTION, NO OSB IS TO BE USED ON THIS FABRICATION BRIDGES” THE FOLLOWING CONDITIONS: PROJECT. CONFIRM WITH ARCHITECT. CONFORM TO “CONSTRUCTION AND TH AISC “MANUAL OF STEEL CONSTRUCTION, 14 EDITION” INDUSTRIAL PLYWOOD” BASED ON PRODUCT STANDARD PS 1-09 BY THE US CONFORM TO ACI 301 SECTION 3.2.2, AND ACI SP-66. · CONCEALED BY THE INTERIOR BUILDING FINISHES AWS D1.1 “STRUCTURAL WELDING CODE - STEEL” DEPARTMENT OF COMMERCE AND “PERFORMANCE STANDARD FOR WOOD · FIREPROOFED 2009 RCSC “SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH STRENGTH BASED STRUCTURAL USE PANELS” BASED ON PRODUCT STANDARD PS 2-10 BY CONCRETE COVER BOLTS” · EMBEDDED IN CONCRETE THE US DEPARTMENT OF COMMERCE AND “PLYWOOD DESIGN SPECIFICATION” CONFORM TO THE FOLLOWING COVE REQUIREMENTS UNLESS NOTED · WELDED; IF AREA REQUIRES PAINTING, DO NOT PAINT UNTIL AFTER WELD BASED ON APA D510C-12 BY THE AMERICAN PLYWOOD ASSOCIATION. UNLESS OTHERWISE IN THE DRAWINGS: INSPECTIONS AND NON-DESTRUCTIVE TESTING REQUIREMENT, IF ANY, ARE NOTED OTHERWISE, SHEATHING SHALL COMPLY WITH THE FOLLOWING TABLE: MATERIALS CONCRETE CAST AGAINST EARTH 3” SATISFIED. WIDE FLANGE (W) SHAPES ASTM A992 Fy=50 KSI CONCRETE PERMANENTLY EXPOSED TO EARTH OR WEATHER 2” · INTERIOR STEEL, EXPOSED TO VIEW, SHALL BE PAINTED WITH ONE COAT OF TIES IN PLINTHS 1 1/2” ANGLE (L) SHAPES ASTM A36 Fy=36 KSI SHOP PRIMER UNLESS OTHERWISE INDICATED IN THE PROJECT STRUCTURAL PLATE (PL) ASTM A36 Fy=36 KSI SPECIFICATIONS. FIELD TOUCH-UPS TO MATCH THE FINISH COAT OR AS BARS EXPOSED TO INTERIOR CONDITIONS ONLY 1” HOLLOW STRUCTURAL SECTION (HSS) AST A500 GRADE B Fy=46 KSI OTHERWISE INDICATED IN THE PROJECT SPECIFICATIONS. HIGH STRENGTH BOLTS ASTM A325/F1852, TYPE 1 OR 3 SPLICES HEAVY HEX NUTS ASTM A563 PER RCSC TABLE 2.1 EXPOSED EXTERIOR STEEL SHALL BE PROTECTED BY ONE OF TWO WAYS. PAINT CONFORM TO ACI 301 SECTION 3.3.2.7. REFER TO TYPICAL LAP SPLICE AND WASHERS ASTM F436 PER RCSC TABLE 2.1 WITH AN EXTERIOR MULTI-COAT SYSTEM AS PER THE PROJECT SPECIFICATIONS, DEVELOPMENT LENGTH SCHEDULE FOR TYPICAL REINFORCEMENT SPLICES. OR BY GALVANIZING. ALL STEEL ELEMENTS NO PROTECTED WITH A PAINT SPLICED INDICATED ON INDIVIDUAL SHEETS SHALL CONTROL OVER THE ANCHOR RODS/BOLTS ASTM 1554 GR. 36 TIMBER CONNECTORS SYSTEM SHALL BE HOT-DIPPED GALVANIZED. SCHEDULE. MECHANICAL CONNECTIONS MAY BE USED WHEN APPROVED BY WELDED HEADED STUD ASTM A108-NELSON/TRW H4L TIMBER CONNECTORS SHALL BE BY THE SIMPSON STRONG TIE COMPANY AS THE ENGINEER OR RECORD. IF TWO BARS OF UNEQUAL DIAMETER ARE SPLICED, SPECIFIED IN THEIR LATEST CATALOG. ALTERNATE CONNECTORS BY OTHER THE SPLICE LENGTH OF THE LARGER BAR SHALL CONTROL. JOINTS USING HIGH STRENGTH BOLTS WOOD FRAMING MANUFACTURES MAY BE SUBSTITUTED PROVIDED THAT THEY HAVE CURRENT · USE ASTM A325-N BOLTS. THREADS NOT EXCLUDED IN THE SHEAR PLANE. IBC CHAPTER 23 “WOOD” ICC APPROVAL FOR EQUIVALENT OR GREATER LOAD CAPACITIES AND ARE FIELD BENDING · HIGH STRENGTH BOLTED JOINTS HAVE BEEN DESIGNED AS BEARING NDS 2016 “NATIONAL DESIGN SPECIFICATION (NDS) FOR WOOD REVIEWED AND APPROVED BY THE ENGINEER OF RECORD PRIOR TO ORDERING. CONFORM TO ACI 301 SECTION 3.3.2.8. BAR SIZES #3 THROUGH #5 MAY BE FIELD CONNECTIONS. CONSTRUCTION” BENT COLD THE FIRST TIME. SUBSEQUENT BENDS AND OTHER BAR SIZES · PROVIDE ASTM BOLT GRADE AND TYPE AS SPECIFIED IN THE “MATERIALS” ANSI/AF&PA SDPWA-15 SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC CONNECTORS SHALL BE INSTALLED PER THE MANUFACTURERS INSTRUCTIONS. REQUIRE PREHEATING. DO NOT TWIST BARS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE LIST ABOVE. APA D510C-12 PLYWOOD DESIGN SPECIFICATION NAILS OR BOLTS IN EACH MEMBER. WHERE STRAPS ARE USED AS HOLD-DOWNS, · PROVIDE WASHERS OVER OUTER PLY OF SLOTTED HOLES AND OVERSIZE ANSI/TPI 1-2014 “NATIONAL DESIGN STANDARD FOR METAL PLATE NAIL STRAPS TO WOOD FRAMING JUST PRIOR TO DRYWALL APPLICATIONS, AS POST-INSTALLED ANCHORS HOLES PER RCSC TABLE 6.1 CONNECTED WOOD TRUS CONSTRUCTION” LATE AS POSSIBLE IN THE FRAMING PROCESS TO ALLOW THE WOOD TO SHRINK STANDARDS · PROVIDE NUT AND WASHER GRADES, TYPES AND FINISHES CONFORMING TO BCI “GUIDE TO GOOD PRACTICE FOR HANDLING, INSTALLING AND BRACING AND THE BUILDING TO SETTLE. PREMATURE NAILING OF THE STRAP MAY LEAD IBC CHAPTER 19 “CONCRETE” TCSC SPECIFICATION TABLE 2.1 OF METAL PLATED CONNECTED WOOD TRUSSES” TO STRAP BUCKLING AND POTENTIAL FINISH DAMAGE. · PROVIDE FASTENER ASSEMBLIES FROM A SINGLE SUPPLIER TPI DSB “RECOMMENDED DESIGN SPECIFICATION FOR TEMPORARY BRACING ACI 318-14 “BUILDING CODE REQUIREMENT FOR STRUCTURAL CONCRETE” · JOINTS SHALL BE “ST” OR SNUG TIGHT. THIS IS FOR TYPICAL BEAM END OF METAL PLATE CONNECTED WOOD TRUSSES” WHERE CONNECTORS ARE IN EXPOSED EXTERIOR APPLICATIONS IN CONTACT POST-INSTALLED ANCHORS (SHEAR TAB) CONNECTIONS, UNLESS NOTED OTHERWISE. APA REPORT TT-045B “MINIMUM NAIL PENETRATION FOR WOOD WITH THE PRESERVATIVE TREATED WOOD (PT) OTHER THAN CCA, CONNECTORS · INSTALL BOLTS IN JOINTS IN ACCORDANCE WITH THE RCSC SPECIFICATION STRUCTURAL PANEL CONNECTIONS SUBJECT TO LATER LOADS” SHALL BE EITHER BATCH HOT-DIPPED GALVANIZED (HDG), MECHANICALLY INSTALL ONLY WHERE SPECIFICALLY SHOWN IN THE DETAILS OR ALLOWED BY SECTION 8 TABLE 4.1 GALVANIZED (ASTM B695 CLASS 55 MINIMUM) STAINLESS STEEL, OR PROVIDED THE ENGINEER OF RECORD. ALL POST INSTALLED ANCHORS TYPES AND · INSPECTIONS PER RCSC SECTION 9. DEFERRED SUBMITTALS WITH 1.85 OX/SF OF ZINC GALVANIZING EQUAL TO OR BETTER THAN SIMPSON LOCATIONS SHALL BE APPROVED BY THE ENGINEER OR RECORD AND SHALL HAVE A CURRENT ICC-EVALUATION SERVICE REPORT THAT PROVIDES SUBMIT PRODUCT DATA AND PROOF OF ICC APPROVAL FOR FRAMING MEMBERS ZMAX FINISH. RELEVANT DESIGN VALUES NECESSARY TO VALIDATE THE AVAILABLE ANCHORAGE TO CONCRETE AND FASTENERS THAT HAVE BEEN DESIGNED BY OTHERS. SUBMIT STRENGTH EXCEEDS THE REQUIRED STRENGTH. ALL STEEL COLUMNS SHALL BE PROVIDED WITH A MINIMUM OF FOUR ¾” CALCULATIONS PREPARED BY THE SPECIALTY STRUCTURAL ENGINEER IN THE NAIL STRAPS TO WOOD FRAMING AS LATE AS POSSIBLE IN THE FRAMING DIAMETER ANCHOR RODS. COLUMN BASE PLATES SHALL BE AT LEAST ¾” THICK, STATE OF IDAHO FOR ALL MEMBERS AND CONNECTIONS DESIGNED BY OTHERS PROCESS TO ALLOW THE WOOD TO SHRINK AND THE BUILDING TO SETTLE. SUBMIT CURRENT MANUFACTURERS DATA AND ICC ESR REPORT TO ENGINEER UNLESS NOTED OTHERWISE. CAST-IN-PACE ANCHOR RODS SHALL BE PROVIDED ALONG WITH SHOP DRAWINGS. ALL NECESSARY BRIDGING, BLOCKING, PREMATURE NAILING OF THE STRAP MAY LEAD TO STRAP BUCKLING AND OF RECORD FOR APPROVAL REGARDLESS OF WHETHER OR NOT IT IS A UNLESS OTHERWISE APPROVED BY THE ENGINEER OR RECORD. UNLESS NOTED BLOCKING PANELS AND WEB STIFFENERS SHALL BE DETAILED AND FURNISHED POTENTIAL FINISH DAMAGE. PRE-APPROVED ANCHOR. ANCHORS SHALL BE INSTALLED IN STRICT OTHERWISE, EMBEDMENT OF CAST-IN-PLACE ANCHOR RODS SHALL BE 12 TIMES BY THE SUPPLIER. TEMPORARY AND PERMANENT BRIDGING SHALL BE THE ANCHOR DIAMETER. INSTALLED IN CONFORMANCE WITH THE MANUFACTURERS SPECIFICATIONS. FASTENERS ACCORDANCE TO ICC-ESR AND THE MANUFACTURERS PRINTED INSTALLATION DEFLECTION LIMITS SHALL BE AS NOTED UNDER DEFERRED SUBMITTALS INSTRUCTIONS IN CONJUNCTION WITH EDGE DISTANCE, SPACING, AND FASTENERS ARE TO INCLUDE NAILS, BOLTS, SCREWS, AND ALL OTHER SIMILAR 309 S DUNHAM AVE SECTION SPECIFIC DETAILS. PRODUCTS TO INCLUDE ARE: SOLID WE WOOD EMBEDMENT DEPTH AS INDICATED ON THE DRAWINGS. FABRICATION JOISTS. MEMBERS. ATTACHING TIMBER CONNECTORS (E.G. HANGARS) TO PT WOOD ARLINGTON, WA 98223 CONFORM TO AISC 360 SECTION M2. THE FOLLOWING QUALITY CONTROL (QC) SHALL HAVE SIMILAR CORROSION RESISTANCE PROPERTIES AS THE PROTECTED THE CONTRACTOR SHALL ARRANGE FOR A MANUFACTURERS FIELD STANDARDS SHALL BE CONFORMED TO: CONNECTOR. FASTENERS ATTACHING SAWN TIMBER MEMERS OR SHEATHING IDENTIFICATION REPRESENTATIVE TO PROVIDE INSTALLATION TRAINING FOR ALL PRODUCTS TO · AISSC 360 CHAPTER N “QUALITY CONTROL AND QUALITY ASSURANCE” TO PT WOOD SHALL BE CORROSION RESISTANT. VERIFY THE SUITABILITY OF BE USED, PRIOR TO THE COMMENCEMENT OF WORK. ONLY TRAINED INSTALLED ALL SAWN LUMBER AND PRE-MANUFACTURED WOOD PRODUCTS SHALL BE THE FASTENER PROTECTION/COATING WITH THE WOOD TREATMENT CHEMICAL · AISE 303 SECTION 8 “QUALITY CONTROL” SHALL PERFORM POST INSTALLED ANCHOR INSTALLATION. A RECORD OF IDENTIFIED BY THE GRADE MARK OR CERTIFICATE OF INSPECTION ISSUED BY MANUFACTURER/SUPLIER. · FABRICATOR AND ERECTOR SHALL ESTABLISH AND MAINTAIN WRITTEN QC THE CERTIFYING AGENCY. TRAINING SHALL BE KEPT ON SITE AND BE MADE AVAILABLE TO THE ENGINEER PROCEDURES PER AISC 360 SECTION N3 OF RECORD AS REQUESTED. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG · FABRICATOR SHALL PERFORM SELF-INSPECTIONS PER AISC 360 SECTION N5 SAWN LUMBER SCREWS BEARING ON WOOD. BOLTS AND LAG BOLTS ARE TO CONFORM TO TO ENSURE THAT THEIR WORK IS PERFORMED IN ACCORDANCE WITH CODE ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY INCLINED OF STANDARD PRACTICE, THE AISC SPECIFICATION, CONTRACT DOCUMENTS SAWN LUMBER SHALL CONFORM TO GRADING RULES OF WWPA, WCLIB, OR ASTM A307 AND IBC SECTION 2304.10. NAILS AND STAPLES SHALL CONFORM TO ORIENTATION SHALL BE PERFORMED BY A CERTIFIED ADHESIVE ANCHOR AND THE APPLICABLE BUILDING CODE. NLGA AND THE TABLE BELOW. FINGER JOINTED STUDS ACCEPTABLE AT ASTM F1667 AND IBC SECTION 2303.6 AND 2304.10. INSTALLER AS CERTIFIED THROUGH ACI/CRSI OR APPROVED EQUIVALENT. INTERIOR WALLS ONLY. SMITH REMODEL · QC INSPECTION MAY BE COORDINATED WITH QUALITY ASSURANCE PROOF OF CURRENT CERTIFICATION SHALL BE SUBMITTED TO THE ENGINEER INSPECTIONS PER SECTION N5.3 WHERE FABRICATORS QA PROCEDURES ENGINEERED WOOD PRODUCTS FOR APPROVAL PRIOR TO COMMENCEMENT OF INSTALLATION. PROVIDE THE NECESSARY BASIS FOR MATERIAL CONTROL, INSPECTION, AND THE FOLLOWING MATERIALS ARE BASED ON LUMBER MANUFACTURED BY CONTROL OF THE WORKMANSHIP EXPECTED BY THE SPECIAL INSPECTOR. TRUSJOIST AND WERE USED FOR THE DESIGN AS SHOWN ON THE PLANS. NO REINFORCING BARS SHALL BE DAMAGED DURING INSTALLATION OF ALTERNATE PRODUCT BY OTHER MANUFACTURERS MAY BE SUBSTITUTED POST-INSTALLED ANCHORS. ANCHOR TYPE, DIAMETER AND EMBEDMENT SHALL WELDING PROVIDED THEY HAVE CURRENT ICC APPROVAL FOR EQUIVALENT OR GREATER BE AS INDICATED ON DRAWINGS. LOAD AND STIFFNESS PROPERTIES AND ARE REVIEWED AND APPROVED BY THE THE FOLLOWING WELDING STANDARDS SHALL BE CONFORMED TO: ENGINEER OF RECORD PRIOR TO ORDERING. · WELDING SHALL CONFORM TO AWS D1.1 WITH PREQUALIFIED WELDING ADHESIVE ANCHORS PROCESSES EXCEPT AS MODIFIED BY AISC 360 SECTION J2. WELDERS SHALL THE LISTED ADHESIVE-TYPE ANCHORING SYSTEMS HAVE BEEN USED IN THE BE QUALIFIED IN ACCORDANCE WITH AWS D1.1 REQUIREMENTS. DESIGN AND SHALL BE USED FOR ANCHORAGE TO CONCRETE, AS APPLICABLE · USE 70KSI STRENGTH, LOW-HYDROGEN TYPE ELECTRODES (E7018) OR E71T AND IN ACCORDANCE WITH CORRESPONDING CURRENT ICC ESR REPORT. AS APPROPRIATE FOR THE PROCESS SELECTED. REFERENCE THE CORRESPONDING ICC ESR REPORT FOR REQUIRED MINIMUM · WELDING OF HIGH STRENGTH ANCHOR RODS IS PROHIBITED UNLESS AGE OF CONCRETE, CONCRETE TEMPERATURE RANGE, MOISTURE CONDITION, APPROVED BY ENGINEER. LIGHT WEIGHT CONCRETE, AND HOLE DRILLING AND PREPARATION REQUIREMENTS. DRILLED IN ANCHOR EMBEDMENT LENGTHS SHALL BE AS · WELDING OF HEADED STUD ANCHORS SHALL BE IN ACCORDANCE WITH AWS PERMIT 01/16/2025 D1.1 CHAPTER 7. SHOWN ON DRAWINGS. ADHESIVE ANCHORS ARE TO BE INSTALLED IN CONCRETE AGED A MINIMUM OF 21 DAYS, UNLESS OTHERWISE SPECIFIED IN THE GLULAM ICC ESR REPORT. ERECTION GLUED LAMINATED TIMER SHALL CONFORM TO AITC 117-2010 “STANDARD THE FOLLOWING ERECTION STANDARDS SHALL BE CONFORMED TO: SPECIFICATIONS FOR STRUCTURAL GLUE-LAMINATED TIMBER OF SOFTWOOD EXPANSION ANCHORS · CONFORM TO AISC 360 SECTION M4 “ERECTION” AND AISC 303 SECTION 7 SPECIES, MANUFACTURING AND DEISGN” AND ANSI/AITC A190.1 “STRUCTURAL THE LISTED EXPANSION TYPE ANCHORS ARE PRE-APPROVED FOR ANCHORAGE “ERECTION.” GLUED LAMINATED TIMER.” CAMBER ALL GLUED LAMINATED BEAMS, EXCEPT TO CONCRETE IN ACCORDANCE WITH CORRESPONDING CURRENT ICC ESR · CONFORM TO AISC CHAPTER N “QUALITY CONTROL AND QUALITY CANTILEVERED AND CONTINUOUS BEAMS, TO 3000' RADIUM, UNLESS SHOWN NAILING REQUIREMENTS REPORT. ASSURANCE” AND AISC 303 SECTION 8. THE ERECTOR SHALL MAINTAIN OTHERWISE ON THE PLANS. FABRICATE CANTILEVERED AND CONTINUOUS CONFORM TO IBC SECTION 2304.10 “CONNECTION AND FASTENERS.” UNLESS DETAILED ERECTION QUALITY CONTROL PROCEDURES THAT ENSURE THAT BEAMS FLAT, UNLESS SHOWN OTHERWISE ON PLANS. GLLULAM MEMBERS TO NOTED ON PLANS, NAIL PER TABLE 2304.10.1. NAILING FOR ROOF/FLOOR THE WORK IS PERFORMED IN ACCORDANCE WITH THESE REQUIREMENT AND CONFORM TO THE TABLE BELOW. SCREW ANCHORS DIAPHRAGMS/SHEAR WALLS SHALL BE PER DRAWINGS. NAILS SHALL BE DRIVEN THE CONTRACT DOCUMENTS. THE LISTED SCREW TYPE ANCHORS ARE PRE-APPROVED FOR ANCHORAGE TO FLUSH AND SHALL NOT FRACTURE THE SURFACE OF SHEATHING. ALTERNATE · STEEL WORK SHALL BE CARRIED UP TRUE AND PLUMB WITHIN THE LIMITS CONCRETE IN ACCORDANCE WITH CORRESPONDING CURRENT ICC ESR REPORT. NAILS MAY BE USED BY ARE SUBJECT TO REVIEW AND APPROVAL BY THE DEFINED IN AISC 303 SECTION 7.13 STRUCTURAL ENGINEER. SUBSTITUTION OF STAPLES FOR THE NAILING OF ADHESIVE · HIGH STRENGTH BOLTING SHALL COMPLY WITH THE RCSC REQUIREMENTS RATED SHEATHING IS SUBJECT TO REVIEW BY THE STRUCTURAL ENGINEER INCLUDING RCSC SECTION 7.2 “REQUIRED TESTING” AS APPLICABLE AND PRIOR TO CONSTRUCTION. HILTI HIT-HY 200 ICC ESR 3187 AISC 360 CHAPTER J, SECTION M2.5 AND SECTION N5.6 SIMPSON SET-XT ICC ESR 2508 · WELDING HEADED STUD ANCHORS SHALL BE IN ACCORDANCE WITH AWS UNLESS NOTED OTHERWISE ON PLANS, ALL NAILS ARE COMMON WIRE NAILS D1.1 CHAPTER 7 “STUD WELDING” AND ARE TO HAVE THE MINIMUM DIMENSIONS AS SHOW IN THE TABLE BELOW. EXPANSION · THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AND SAFETY HILTI KWIK BOLT TZ ICC ESR 1917 PROTECTION REQUIRED BY AISC 360 SECTION M4.2 AND AISC 303 SECTION 24081-0106 SIMPSON STRONG-BOLT 2 ICC ESR 3037 7.10 AND 7.11 S-1.1 DEWALT POWER-STUD +SD2 ICC ESR 2502 01/16/2025 GENERAL SCREW NOTES NTS SIMPSON TITEN HD ICC ESR 2713 HILTI KWIK HUZ-EZ ICC ESR 3027 DEWALT SNAKE ICC ESR 2272 LIGHT-FRAME CONSTRUCTION UNLESS NOTED ON THE PLANS, CONSTRUCTION SHALL CONFORM TO IBC SECTION 2308 “CONVENTIONAL LIGHT0FRAME CONSTRUCTION.” NAILERS ON STEEL MEMBERS WOOD 3X NAILERS ARE GENERALY REQUIRED ON ALL HSS COLUMNS AND STEEL BEAMS ABUTTING OR EMBEDDED WITHIN WOOD FRAMING. UNLESS NOTED OTHERWISE, ATTACH WITH 5/8” DIAMETER BOLTS OR WELDED STUDS AT 16” OC. UNLESS ANOTHER OTHERWISE, WOOD NAILERS ON BEAMS SUPPORTING JOIST HANGARS SHALL NOT OVERHAND THE BEAM FLANGE BY MORE THAN ¼” WOOD SHRINKAGE AND EXPANSION WOOD MATERIALS WILL EXPAND OR CONTRACT BASED ON RELATIVE CHANGES IN MOISTURE. THE CONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION RELATED TO MITIGATING AND MANAGING THE EFFECTS OF CHANGES IN MOISTURE. MOISTURE CONTENT WOOD MATERIAL USED FOR THIS PROJECT SHALL HAVE MAXIMUM MOISTURE CONTENT OF 19% EXCEPT FOR THE PRESSURE-TREATED WOOD SILL PLATE. REFER TO TESTING AND INSPECTION FOR THE VERIFICATION OF THESE LIMITS. THE MAXIMUM MOISTURE CONTENT REQUIRED MAY BE LESS THAN 19% WHEN BASED ON A PARTICULAR CLADDING/INSULATION SYSTEM. REFER TO THE ARCHITECTS DRAWINGS, AND PROJECT SPECIFICATIONS, OR WITH CLADDING INSTALLER FOR MAXIMUM RECOMMENDED MOISTURE CONTENT. SHRINKAGE COMPENSATION FOR MEP SYSTEMS MEP SYSTEMS, INCLUDING DUCTWORK, PIPES, AND OTHER ELEMENTS THAT RUN CONTINUOUSLY BETWEEN LEVELS SHALL BE INSTALLED/DESIGNED IN SUCH A MANNER TO ACCOMMODATE SHRINKAGE IN THE WOOD FRAMING. WOOD SHRINKAGE AMOUNTS WILL VARY DEPENDING ON THE CONSTRUCTION PROCESS AND MATERIALS USED. THE ANTICIPATED SHRINKAGE UNDER TYPICAL CONDITIONS IS EXPECTED TO RANGE BETWEEN 1/8” AND ¼” PER FLOOR. PRESERVATIVE TREATMENT WOOD MATERIALS THAT ARE REQUIRED TO BE “TREATED WOOD” IN ACCORDANCE WITH IBC SECTION 2304.12 “PROTECTION AGAINST DECAY AND TERMITE PROTECTION” SHALL CONFORM TO THE APPROPRIATE STANDARDS OF THE AMERICAN WOOD-PRESERVES ASSOCIATION (AWPA) FOR SAWN LUMBER BLUED LAMINATED TIMBER, ROUND POLES, WOOD PILES, AND MARINE PILES. FOLLOW AMERICAN LUMBER STANDARDS COMMITTEE (ALSC) QUALITY ASSURANCE PROCEDURES. PRODUCTS SHALL BEAR THE APPROPRIATE MARK. FASTENERS OR ANCHORS IN TREATED WOOD SHALL BE OF STAINLESS STEEL OR HOT-DIPPED GALVANIZED OR AS PER IBC 2304.10.5 MUD SILL PLATES IN NORMALLY DRY INTERIOR APPLICATIONS MAY BE TREATED WITH SODIUM BORATE (DOT-DISODIUM OCTABORATE TELRAHYDRATE) AS RECENT STUDIES HAVE NOTED LESS CONNECTOR 309 S DUNHAM AVE CORROSION POTENTIAL THAN OTHER AVAILABLE WOOD TREATMENTS OR THE ORIGINAL CCA TREATED SILL PLATES. WOOD TREATED WITH SODIUM BORATE ARLINGTON, WA 98223 SHALL BE PROTECTED DURING SHIPMENT, STORAGE, AND INSTALLATION TO MINIMIZE LEACHING OF THE WATER-SOLUBLE PRESERVATIVE FROM THE LUMBER. SODIUM BORATE PRESSURE TREATED PLATED DO NOT REQUIRE HOT-DIPPED GALVANIZED CONNECTORS. IF USING PRESERVATIVE TREATMENTS OTHER THAN CCA OR SODIUM BORATE, FASTENERS MUST BE HOT DIPPED GALVANIZED OR STAINLESS STEEL. WOOD TREATED WITH ALKALINE COPPY QUATERNARY (ACQ) REQUIRES STEEL COMPONENTS IN CONTACT WITH THE WOOD TO BE STAINLESS. FASTENERS ATTACHING TIMBER CONNECTORS TO PT WOOD SHALL HAVE SIMILAR SMITH REMODEL CORROSION RESISTANCE PROPERTIES AS THE PROTECTED CONNECTOR, THAT IS, USE HOT DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. FASTENERS ATTACHING SAWN TIMBER MEMBERS OR SHEATHING TO PRESSURE TREATED WOOD SHALL BE CORROSION RESISTANT. ALWAYS VERIFY THE SUITABILITY OF THE FASTENER PROTECTION/COATING PERMIT 01/16/2025 24081-0106 S-1.2 01/16/2025 GENERAL NOTES NTS 5" Ø X 24" SMOOTH BAR @ SLAB ON GRADE AND (3) #5 DOWELS. DRILL AND EPOXY 8" MIN 8 INTO FACE OF EXISTING FOOTING. SIMPSON 24" OC. GREASE ONE REINFORCING PER SIDE OF DOWEL PLAN, TYPICAL SET-XP EPOXY OR ACCEPTABLE TOP OF ALTERNATIVE. SLAB NEW STEM WALL, FOOTING, AND REINFORCING PER PLAN 16" MIN 4d 2 1" MIN 2 VAPOR BARRIER WHERE 6" SUBGRADE PREPARATION PER REQUIRED, TYPICAL GEOTECH REPORT, TYPICAL COMPETENT NATIVE SOIL PER 90° 45° CONSTRUCTION JOINT GEOTECH REPORT, TYPICAL R R SAW CUT OR 1 1" WIDE PREMOLDED R 180° 2 12d JOINT. DEPTH OF JOINT TO BE 1 OF THE SLAB THICKNESS 4 R FOOTING INTO PLINTH 45° TOP OF 3" SLAB R = 6d FOR #3 THROUGH #8 R = 8d FOR #9 THROUGH #11 EXISTING BASEMENT STRUCTURAL FILL. WALL 95% COMPACTION. 12" MAX LIFTS, TYP CONTROL JOINT NOTES NOTES d = DIAMETER OF REINFORCING BAR NOTES 1. CONSTRUCTION JOINT IS A JOINT BETWEEN DIFFERENT POURS. CONTROL JOINT IS A CRACK CONTROL JOINT WITHIN THE SAME POUR. R = RADIUS OF BAR BEND 1. ALL VALUES ARE IN INCHES. 2. USE EARLY ENTRY DRY-CUT SAW AS SOON AS POSSIBLE WITHOUT CAUSING RAVELING OF 2. TOP BAR IS ANY HORIZONTAL BAR WITH AT LEAST CONCRETE EDGES. SAWCUT ALONG SHORT DIRECTION OF POUR FIRST. 3. ALIGN A CONSTRUCTION OR CONTROL JOINT WITH RE-ENTRANT SLAB CORNERS EACH WAY. 12" OF MONOLITHIC POURED CONCRETE BELOW 4. PROVIDE JOINTS TO ENCLOSE APPROXIMATE SQUARE AREA (PANEL) OF 225 SQUARE FEET, MAXIMUM. MAXIMUM PANEL ASPECT RATIO OF 1.3. 5. CONTRACTOR TO SUBMIT JOINT PLAN TO STRUCTURAL ENGINEER OF RECORD FOR REVIEW/APPROVAL POST INSTALLED ANCHORS AT TYPICAL SLAB-ON-GRADE JOINT LAP SPLICE AND DEVELOPMENT 1 FOOTING INTERFACE DETAILS BAR BEND DIAGRAM LENGTH SCHEDULE SCALE: NTS 2 SCALE: 3/4" = 1' 3 SCALE: 3/4" = 1' 4 SCALE: NTS CONCRETE WALL PER PLAN DOWEL WITH STANDARD HOOK TO MATCH FOOTING REINFORCING POST PER PLAN Ld PER SCHED POST BASE PER PLAN. SLAB ON GRADE AND ACTUAL MODEL MAY NOT TOP OF REINFORCING PER PLAN BE SHOWN FOOTING CONCRETE PLINTH H ANCHORAGE PER PLAN PER PLAN 3" CLR, TYPICAL 4' MAX BEND DOWELS TO MATCH 309 S DUNHAM AVE H FOOTING REINFORCING TOP OF LAP PER SCHEDULE, 4' MAX SLAB TYPICAL (3) #4 DOWELS FROM ARLINGTON, WA 98223 FOOTING INTO PLINTH 8" MIN TOP OF FINISHED GRADE STEEP AS POSSIBLE, TYPICAL 2 BENT DOWEL TO MATCH FOOTING REINFORCING FTG 1 TURNED DOWN EDGE 1.5H MIN FOOTING REINFORCING THICKNESS PER PLAN FOOTING AND REINFORCING PER PLAN 3" CLEAR AT CORNERS AT INTERSECTIONS NOTE (2) #4 BOTTOM BAR CAST DOWELS TO MATCH VERTICAL WALL REINFORCING. NOT SHOWN PER PLAN FOR CLARITY. NOTE: SMITH REMODEL FOOTING REINFORCING PER PLAN. BOTTOM OF FOOTING BELOW FROST DEPTH PER JURISDICTION TURNED DOWN EDGE AT SLAB-ON- CORNER AND INTERSECTING POST FOOTING AT CONCRETE TYPICAL STEPPED FOOTING GRADE 7 FOOTINGS PLINTH 5 SCALE: 1/2" = 1' 6 SCALE: 1" = 1' SCALE: 3/4" = 1' 8 SCALE: 3/4" = 1' STUD WALL AND SHEATHING PER PLAN BUNDLED STUDS PER PLAN. STUD WALL AND SHEATHING PERMIT 01/16/2025 SECTION 2 STUDS, MIN. PT PLATE AND ANCHOR PIPE SLEEVE AS BOLTS PER PLAN REQUIRED, TYPICAL EXPANSION JOINT AT SLAB PT BOTTOM PLATE STEM WALL PER PLAN ON GRADE, IF APPLICABLE #4 HORIZONTAL BARS @ 18" WITH ANCHOR BOLTS PER 11/S-4.0 OC CENTERED IN WALL SLAB ON GRADE AND 1" CLR, REINFORCING WHERE OCCURS TYPICAL STRAP HOLD DOWN PER PLAN #4 HOOKED VERTICAL BARS @ 18" OC CENTERED IN WALL TOP OF CONCRETE FOOTING PER PLAN FINISHED GRADE TOP OF FOOTING 4" MIN CONCRETE STEMWALL BOT OF TOP OF PER PLAN PER PLAN FOOTING 3'-0' MAX FINISHED GRADE FOOTING DEPTH 4" MIN AT CONTRACTORS OPTION, TURNED DOWN EDGE EXCAVATION FOR TRENCH CONCRETE FOOTING AND 3'-0" MAX 6" MIN NOT ALLOWED BELOW THIS REINFORCEMENT PER PLAN EQ EQ LINE 18" MIN 1 3" CLR PLACE CONCRETE FILL 1 BEFORE FOOTING POUR ALTERNATE HOOK NOTES EVERY OTHER BAR 1. PRIOR TO CONSTRUCTION, STRUCTURAL ENGINEER OF RECORD SECTION SHALL REVIEW PIPES/SLEEVES GREATER THAN 8" DIAMETER NOTE AND/OR SPACED CLOSER THAN 3" APART. AT "SIM" CONDITION, OMIT SLAB ON GRADE, 2. ALUMINUM MATERIALS SHALL NOT BE EMBEDDED IN CONCRETE. AND EPOXY VERTICAL REINFORCING INTO EXISTING STEM WALL TO MATCH 5/S3.0 24081-0106 S-2.0 01/16/2025 TYPICAL EXTERIOR STEM WALL AND FOUNDATION DETAILS TYPICAL PIPE THROUGH FOUNDATION FOOTING AND/OR STEMWALL STRAP HOLD DOWN INSTALLATION FOOTING AS NOTED 9 SCALE: 1/2" = 1' 11 SCALE: NTS 12 SCALE: 3/4" = 1' STRAP AND NAILING PER PLAN EDGE NAILING FULL BUNDLED STUDS OR HEIGHT OF STUD EDGE NAILING PER PLAN POST PER PLAN ADDITIONAL STUD, IF HOLD DOWN PER PLAN REQUIRED PER STRAP STUD OR SHEAR WALL CONTINUES, WHERE OCCURS PER PLAN STUD OR SHEAR WALL CONTINUES, WHERE OCCURS PER PLAN STAGGER 0.131"Øx31" NAILS STAGGER 0.131"Øx31" NAILS 2 2 PER SHEAR WALL SCHEDULE PER SHEAR WALL SCHEDULE EDGE NAILING PER PLAN EDGE NAILING PER PLAN STUD WALL AND SHEATHING STUD WALL AND SHEATHING PER PLAN PER PLAN 3 CORNER AND INTERSECTING SHEAR WALLS SCALE: 1" = 1' ANCHOR BOLT PER 11/S-4.0, TYPICAL ANCHOR BOLT PER 11/S-4.0 PT SILL PLATE PER PLAN, TYIPCAL SHEATHING WHERE OCCURS PER PLAN WALL STUD SPACING HOLD DOWN PER PLAN PER PLAN, TYP TYPICAL BUNDLED STUDS PER PLAN 5" MIN, 12" MAX 5" MIN, 12" MAX NOTCH IN SILL PLATE 8" MAX WALL STUDS PER PLAN NOTES: 1. ADDITIONAL INFORMATION PER 10/S-3.0 2. TREAT NOTCHES IN SILL PLATES AS WALL ENDS. PROVIDE ANCHOR ON BOTH NOTE: SIDES. SINGLE TIMBERS MAY BE USED IN LIEU OF 3. AT SHEAR WALLS, PLATE WASHER PER SHEAR WALL SCHEDULE. STANDARD CUT BUNDLED STUDS, PROVIDED THAT TOTAL WOOD SMITH REMODEL WASHERS AT NON SHEAR WALLS. CROSS SECTION AREA REMAINS THE SAME. 7 SILL PLATE ANCHORAGE - PLAN END OF SHEAR WALLS SCALE: 1" = 1' 8 SCALE: 1" = 1' STUD WALL PER PLAN 5" MIN STUDS PER PLAN 1'-0" MAX 6'-0" MAX PERMIT 01/16/2025 5"Ø ANCHOR BOLT X 6" 8 LONG, TYPICAL WALL END PER PLAN HOLD DOWN PER PLAN PT SILL PLATE ANCHOR ROD PER PLAN TOP OF CONCRETE DRILL AND EPOXY PER PLAN EXISTING CONCRETE WALL CONCRETE STEM WALL PER PLAN NOTES: 1. PROVIDE (2) BOLTS, MINIMUM ON EACH SILL PLATE PIECE. 2. OVERSIZE HOLES ARE NOT PERMITTED. USE 11"Ø 16 DRILL BIT. 3. SILL PLATE THICKNESS PER PLAN. AT SHEAR WALLS, THICKNESS PER SHEAR WALL SCHEDULE. 4. CONTACT ENGINEER OF RECORD FOR POST INSTALLED 24081-0106 ANCHOR OPTIONS. S-3.0 01/16/2025 POST INSTALLED ANCHORS AT WOOD WALL ANCHORAGE FOOTING INTERFACE SILL PLATE ANCHORAGE - SECTION AS NOTED 11 SCALE: NTS 12 SCALE: 1/2" = 1' (2) 2x4 STUDS (3) 2x4 STUDS (3) 2x6 STUDS WALL FRAMING ABOVE, RIM JOIST PER PLAN WHERE OCCURS 1" 21" 11" 31" 11" 1 2 2 2 2 32" FRAMING AT LEVEL ABOVE, BLOCKING, WIDTH TO MATCH WHERE OCCURS HD HOLD DOWN PER PLAN, 8" TYP 8" TYP TRIMMER AND KING STUDS 6" TYP TOP OF WHERE OCCURS SHEATHING ABOVE, WHERE OCCURS RIM JOIST PER PLAN 1" 11" 11" WALL LENGTH PER PLAN 2 2 PLATE NAILING PER PLAN STRAP HOLD DOWN WHERE PONY WALL FRAMING TOP OF SHEATHING OCCURS PER PLAN BOTTOM PLATE SHEATHING PER SHEAR DOUBLE TOP PLATE WALL SCHEDULE DOUBLE TOP PLATE FIELD NAILING PER 2X BLOCKING AT PONY WALL STUDS, TO PLAN, TYP PANEL EDGES MATCH STUDS ABOVE HEADER PER PLAN 1 EDGE NAILING PER TRIMMER STUDS PER (3) 8dx34" NAILS BUNDLED STUDS PER PLAN, TYP PLAN EACH END, TYPICAL PLAN, TYPICAL SILL, IF OPENING HD HOLD DOWN AND STRAP HOLD DOWN, WHERE IS A WINDOW ANCHORAGE PER PLAN OCCURS, PER PLAN (2) 2X4 LAMINATIONS W/ (3) 2X4 LAMINATIONS W/ (1) (3) 2X6 LAMINATIONS W/ (2) (1) ROW OF 10dx31" ROW OF 10dx31" NAILS EACH ROWS OF 10dx31" NAILS EACH 2 2 2 NAILS, STAGGERED LAYER, STAGGERED BETWEEN LAYER, STAGGERED BETWEEN PONY WALL IF OPENING STUD WALL FRAMING LAYERS EACH SIDE LAYERS EACH SIDE IS A WINDOW PER PLAN PT SILL PLATE AND ANCHOR BOLTS PER PLAN CONC STEMWALL & NOTE: FOOTING PER PLAN EACH ADDITIONAL LAMINATION OVER (3) LAMINATIONS SHALL BE NAILED TO THE ASSEMBLY WITH 10dx31" COMMON WIRE NAILS, KING STUD(S) PER PLAN 4 STAGGERED EACH SIDE OF BUNDLED STUDS NAILING FOR BUNDLED STUDS TYPICAL HEADER 4 SHEAR WALL ELEVATION 2 SCALE: 3/4" = 1' 3 SCALE: 1/2" = 1' SCALE: 1/4" = 1' 2 ROWS 10dx31" NAILS, (16) 4 4'-0" MIN SPLICE LAP TOTAL, STAGGERED WITHIN AREA OF SPLICE @ 6" OC PLATE SPLICE TO OCCUR OVER STUDS DOUBLE TOP PLATE A STUD WALL PER PLAN SMITH REMODEL G B C D PLATE SPLICE DETAIL A E 6 F B SCALE: 3/4" = 1' B H MAX NOTCH DEPTH SAW CUT MAX DIAMETER OF D, MIN BETWEEN NOTCH BORED HOLE AND BORED HOLE CIRCULAR NOTCH PERMIT 01/16/2025 J "V" NOTCH MIN DEPTH MIN REMAINING DEPTH LET-IN NOTCH 1. INSTALL PANEL EITHER HORIZONTALLY OR VERTICALLY. 2. BLOCKING REQUIRED ON ALL PANEL EDGES, EXCEPT AT W6 WALLS. D, MIN BETWEEN TWO 3. SHEATHING EDGE NAILING IS REQUIRED AT ALL HOLD DOWN POSTS. EDGE NAILING MAY ALSO BE REQUIRED TO EACH STUD USED IN BUILT-UP HOLD BORED HOLES DOWN POSTS. ADDITIONAL INFORMATION PER HOLD DOWN DETAILS. D, MAX 1 1 4. BASED ON 0.131"Øx1 2" NAILS USED TO ATTACH FRAMING CLIPS DIRECTLY TO FRAMING. USE 0.131"Øx2 2" NAILS WHERE INSTALLED OVER SHEATHING. 5. FRAMING CLIPS: LTP5 MAY BE USED IN LIEU OF A35. STUD WIDTH, D STUD WIDTH, D 6. WHERE BOTTOM PLATE ATTACHMENT SPECIFIES (2) ROWS OF NAILS, PROVIDE DOUBLE JOIST, RIM JOIST, OR EQUAL BELOW. STAGGER NAILS IN ROWS 1 1" APART, MINIMUM. 2 7. ANCHOR BOLTS SHALL BE PROVIDED WITH HOT-DIPPED GALVANIZED STEEL PLATE WASHERS 0.229"x3"x3" MINIMUM. THE HOLE IN THE PLATE WASHER MAY BE DIAGONALLY SLOTTED 13"x1 3" PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND NUT. PLATE WASHER 16 4 TO EXTEND TO WITHIN 1" OF THE EDGE OF TEH SILL PLATE ON THE SIDE WITH SHEATHING. AT 2x6 WALLS WITH SHEATHING ON BOTH SIDES USE 2 PLATE WASHER 0.229"x4 1"x4 1" MINIMUM. EMBED ANCHOR BOLTS 7" MINIMUM INTO THE CONCRETE. 2 2 8. PRESSURE TREATED MATERIAL CAN CAUSE EXCESSIVE CORROSION IN THE FASTENERS. PROVIDE HOT-DIPPED GALVANIZED NAILS AND CONNECTOR PLATES (E.G. CLIPS) FOR ALL CONNECTORS IN CONTACT WITH PRESSURE TREATED FRAMING MEMBERS. ADDITIONAL INFORMATION PER STRUCTURAL GENERAL NOTES. 9. WHERE WOOD SHEATHING IS APPLIED OVER GYPSUM SHEATHING, CONTACT THE ENGINEER OF RECORD FOR ALTERNATIVE NAILING REQUIREMENTS. 10. AT ADJOINING PANEL EDGES (2) 2x STUDS NAILED TOGETHER MAY BE USED IN PLACE OF A SINGLE 3x STUD. DOUBLE 2x STUDS SHALL BE CONNECTED TOGETHER PER DETAIL 1/S-1.1. 11. CONTACT THE STRUCTURAL ENGINEER OF RECORD FOR ADHESIVE OR EXPANSION BOLT ALTERNATIVES TO CAST-IN-PLACE ANCHOR BOLTS. 24081-0106 12. NAIL STUDS TO 3X SILL PLATES WITH EITHER (2) 0.148"Øx4" END NAILS OR (4) 0.131"Øx2 1" TOENAILS. 2 13.EDGE NAILS SHALL BE LOCATED 3" FROM PANEL EDGES. 8 S-3.1 01/16/2025 STANDARD HOLES AND NOTCHES WOOD WALL FRAMING IN STUDS 11 SHEAR WALL SCHEDULE AS NOTED 10 SCALE: 3/4" = 1' SCALE: NTS 1 SHEATHING PER PLAN (2) 8d X 2 2" NAILS FROM JOIST INTO 2x BLOCKING TOP OF SHEATHING JOIST PER PLAN, TYPICAL DIAPHRAGM EDGE NAILING PER PLAN STUD WALL AND ADDITIONAL NAILING & BLOCKING 2x BLOCKING WITH SHEATHING PER PLAN BREAK RIM JOIST AT REQUIRED FOR (2) ROWS OF PLATE 1 BEAM (4) 8d X 2 2" NAILS NAILING PER SHEAR WALL SCHEDULE TOP OF 1" SHEATHING 2 PLATE ATTACHMENT PER DIAPHRAGM EDGE DTC CLIP SHEAR WALL SCHEDULE WEB STIFFENER PER JOIST NAILING PER PLAN BLOCKING @ 48" OC TO MATCH MANUFACTURER. NAIL WITH RIM JOIST PER PLAN JOISTS. MINIMUM OF (2) PER NON BEARING STUD WALL 1 PER ARCH (4) 10d COMMON NAILS X 3 2" DIAPHRAGM EDGE TOP OF WALL SEGMENT NAILING PER PLAN SHEATHING 2x4 W/ (4) 8D X 3 1" NAILS 4 PER PLAN WALL PARALLEL TOP OF BEAM PER PLAN TO JOISTS SHEATHING PER PLAN SHEATHING RIM JOIST PER PLAN TOP OF STUD WALL AND SHEATHING JOIST PER PLAN, TYPICALJOIST PER PLAN, TYPICAL JOIST PER PLAN SHEATHING PER PLAN BLOCKING @ 48" OC W/ (2) 8DX3 1" 4 RIM JOIST CONNECTION PER TOENAILS TO TOP PLATE SHEAR WALL SCHEDULE JOIST PER PLAN LSL BLOCKING TO EXISTING CONCRETE MATCH RIM JOIST WALL PER PLAN DTC CLIP RIM JOIST CONNECTION PER SHEAR WALL SCHEDULE, NON BEARING STUD WALL COLUMN F PER ARCH WALL PERPENDICULAR TO JOISTS NOTES: FLOOR FRAMING AT PARALLEL SIMPSON STRONG TIE SDPW SCREWS MAY BE USED IN LIEU OF DTC JOISTJOISTS EACH SIDE CANTILEVERED BEAM NON BEARING WALL CONNECTIONS FLOOR OVERHANG 1 SCALE: 2 SCALE: 3/4" = 1' 3 SCALE: 3/4" = 1' 4 SCALE: 3/4" = 1' ADDITION SHEAR WALL SHEATHING WHERE APPLICABLE, TYPICAL ADDITION SHEAR WALL SHEATHING WHERE APPLICABLE, TYPICAL PLATE ATTACHMENT PER PLATE ATTACHMENT PER ADDITION SHEAR WALL SHEATHING ADDITIONAL NAILING & BLOCKING SHEAR WALL SCHEDULE SHEAR WALL SCHEDULE WHERE APPLICABLE, TYPICAL REQUIRED FOR (2) ROWS OF PLATE STUD WALL AND PLATE ATTACHMENT PER NAILING PER SHEAR WALL SCHEDULE ADDITIONAL NAILING & BLOCKING ADDITION SHEAR WALL SHEATHING SHEATHING PER PLAN SHEAR WALL SCHEDULE DIAPHRAGM EDGE REQUIRED FOR (2) ROWS OF PLATE DIAPHRAGM EDGE WHERE APPLICABLE, TYPICAL NAILING PER PLAN NAILING PER SHEAR WALL SCHEDULE NAILING PER PLAN ADDITIONAL NAILING & BLOCKING DIAPHRAGM EDGE PLATE ATTACHMENT PER REQUIRED FOR (2) ROWS OF PLATE DIAPHRAGM EDGE NAILING PER PLAN SHEAR WALL SCHEDULE NAILING PER SHEAR WALL SCHEDULE NAILING PER PLAN RIM JOIST PER PLAN RIM JOIST PER PLAN ADDITIONAL NAILING & BLOCKING REQUIRED FOR (2) ROWS OF PLATE TOP OF TOP OF DIAPHRAGM EDGE SHEATHING SHEATHING NAILING PER SHEAR WALL SCHEDULE RIM JOIST PER PLAN 1 NAILING PER PLAN 2x4 W/ (4) 8D X 3 4" NAILS TOP OF RIM JOIST CONNECTION PER SHEATHING SHEAR WALL SCHEDULE WEB STIFFENER WHERE REQD TOP OF SHEATHING BY MANUFACTURER JOIST PER PLAN JOIST PER PLAN W/ (2) 8DX3 1" RIM JOIST CONNECTION PER 4 BLOCKING @ 48" OC W/ (2) 8DX3 1" NAILS TO TOP PLATE SHEAR WALL SCHEDULE 4 TOENAILS TO TOP PLATE JOIST PER PLAN W/ (2) 8DX3 1" RIM JOIST CONNECTION PER NAILS TO TOP PLATE 4 STUD WALL AND STUD WALL AND SHEAR WALL SCHEDULE SHEATHING PER PLAN 1 FULL DEPTH BLOCKING TO SHEATHING PER PLAN JOIST PER PLAN W/ (2) 8DX3 4" NAILS TO TOP PLATE MATCH RIM JOIST STUD WALL AND 2X BLOCKING WITH 2X BLOCKING WITH SHEATHING PER PLAN PLATE ATTACHMENT PER PLATE ATTACHMENT PER RIM JOIST CONNECTION PER WEB STIFFENER WHERE REQD SHEAR WALL SCHEDULE SHEAR WALL SCHEDULE SHEAR WALL SCHEDULE BY MANUFACTURER WEB STIFFENER WHERE REQD BY MANUFACTURER SMITH REMODEL 2X BLOCKING 2X BLOCKING STUD WALL AND SHEATHING PER PLAN FLOOR FRAMING AT CONTINUOUS FLOOR FRAMING PARR/PERP TO FLOOR FRAMING PERPENDICULAR JOIST WALL FLOOR FRAMING PARALLEL TO WALL TO WALL 5 SCALE: 3/4" = 1' 6 SCALE: 3/4" = 1' 7 SCALE: 3/4" = 1' 8 SCALE: 3/4" = 1' ADDITION SHEAR WALL SHEATHING STUD WALL AND ADDITION SHEAR WALL SHEATHING WHERE APPLICABLE, TYPICAL SHEATHING PER PLAN WHERE APPLICABLE, TYPICAL STUD WALL AND PLATE ATTACHMENT PER ADDITION SHEAR WALL SHEATHING STUD WALL AND PERMIT 01/16/2025 ADDITION SHEAR WALL SHEATHING SHEATHING PER PLAN SHEAR WALL SCHEDULE WHERE APPLICABLE, TYPICAL SHEATHING PER PLAN WHERE APPLICABLE, TYPICAL ADDITIONAL NAILING & BLOCKING PLATE ATTACHMENT PER PLATE ATTACHMENT PER ADDITIONAL NAILING & BLOCKING SHEAR WALL SCHEDULE PLATE ATTACHMENT PER REQUIRED FOR (2) ROWS OF PLATE DIAPHRAGM EDGE REQUIRED FOR (2) ROWS OF PLATE SHEAR WALL SCHEDULE SHEAR WALL SCHEDULE ADDITIONAL NAILING & BLOCKING NAILING PER SHEAR WALL SCHEDULE NAILING PER PLAN NAILING PER SHEAR WALL SCHEDULE ADDITIONAL NAILING & BLOCKING REQUIRED FOR (2) ROWS OF PLATE DIAPHRAGM EDGE REQUIRED FOR (2) ROWS OF PLATE NAILING PER SHEAR WALL SCHEDULE DIAPHRAGM EDGE NAILING PER SHEAR WALL SCHEDULE RIM JOIST PER PLAN NAILING PER PLAN NAILING PER PLAN DIAPHRAGM EDGE DIAPHRAGM EDGE TOP OF NAILING PER PLAN SHEATHING NAILING PER PLAN RIM JOIST PER PLAN TOP OF TOP OF TOP OF SHEATHING SHEATHING SHEATHING RIM JOIST PER PLAN 2x4 W/ (4) 8D X 3 1" NAILS 4 RIM JOIST CONNECTION PER SHEAR WALL SCHEDULE WEB STIFFENER WHERE REQD BY MANUFACTURER JOIST PER PLAN W/ (2) 8DX3 1" RIM JOIST CONNECTION PER 4 NAILS TO TOP PLATE SHEAR WALL SCHEDULE JOIST PER PLAN 1 FULL DEPTH BLOCKING TO JOIST PER PLAN W/ (2) 8DX3 1" RIM JOIST CONNECTION PER JOIST PER PLAN W/ (2) 8DX3 4" WEB STIFFENER WHERE REQD 4 NAILS TO TOP PLATE MATCH RIM JOIST BLOCKING @ 48" OC W/ (2) 8DX3 1" NAILS TO TOP PLATE SHEAR WALL SCHEDULE BY MANUFACTURER PT 2X6 PLATE, ATTACHMENT 4 PER SHEAR WALL SCHEDULE TOENAILS TO TOP PLATE WEB STIFFENER WHERE REQD RIM JOIST CONNECTION PER BY MANUFACTURER SHEAR WALL SCHEDULE CONCRETE WALL AND PT 2X6 PLATE, ATTACHMENT PT 2X6 PLATE, ATTACHMENT REINFORCING PER PLAN PER SHEAR WALL SCHEDULE PT 2X6 PLATE, ATTACHMENT PER SHEAR WALL SCHEDULE CONCRETE WALL AND PER SHEAR WALL SCHEDULE CONCRETE WALL AND REINFORCING PER PLAN REINFORCING PER PLAN CONCRETE WALL AND REINFORCING PER PLAN 24081-0106 S-3.2 01/16/2025 GROUND FLOOR FRAMING AT GROUND FLOOR FRAMING GROUND FLOOR FRAMING PARALLEL GROUND FLOOR FRAMING WOOD FLOOR FRAMING AS NOTED CONTINUOUS JOIST PARR/PERP TO WALL TO WALL PERPENDICULAR TO WALL DETAILS 9 SCALE: 3/4" = 1' 10 SCALE: 3/4" = 1' 11 SCALE: 3/4" = 1' 12 SCALE: 3/4" = 1' PT JOIST PER PLAN TOP OF SHEATHING JOIST PER PLAN W/ (2) 8DX3 1" HANGER PER PLAN 4 NAILS TO TOP PLATE LEDGER AND CONNECTION PER PLAN STUD WALL AND SHEATHING PER PLAN TOP OF SHEATHING ROOF FRAMING AT 4 SCALE: 3/4" = 1' BLOCKING AT EACH JOIST SIMPSON HU FACE MOUNT 12 HANGER AT EACH OUTRIGGER PER 5" DIAMETER WELDED 2x4 OUTRIGGER @ 24" OC ARCH 8 COUNTERSINK 1" MAX THREADED STUD @ 16" OC SHEATHING SIMPSON BA OR HB AND 6" FROM EACH END PER PLAN TOP FLANGE HANGER SHEATHING PER PLAN WITH SLOPED SEAT SHEATHING PER PLAN CONTINUOUS 3x NAILER LINE JOIST PER PLATE PLAN TOP OF SHEATHING SIMPSON H1A TIE AT EACH OUTRIGGER RAFTER PER PLAN, TYPICAL BEAM PER PLAN 2'-0" MAX BEAM PER PLAN TRUSS PER PLAN, TYPICAL SMITH REMODEL RIDGE BEAM CONNECTION WOOD NAILER OVER STEEL BEAM ROOF FRAMING PARALLEL TO WALL 6 SCALE: NTS 7 SCALE: 1" = 1' 8 SCALE: EXISTING SHEATHING USS PE 2X BLOCKING STIFFENER PL3" EACH SIDE. WOOD NAILER PER 8 CHAMFER CORNERS TO AVOID K REGION 10/S-4.2 SIMPSON VPA PERMIT 01/16/2025 EXISTING JOIST BEAM PER PLAN CONTINUOUS BEVELED PLATE 1 " 1/4 2 TYP 2'-0" MAX 1/4 2" BEAM PER PLAN HARDWARE OPTION 1 " 2 SHEATHING 1/4 3 PER PLAN WHERE BEAM IS CONTINUOUS CAP PL8" X 6" X 0'-10" 3" MIN CEILING JOISTS OVER THE SUPPORT, EXTEND WITH (2) 3" BOLTS PER PLAN ALL CALLOUTS 4 ROOF RAFTER BEAM PER PLAN, PERP LAN TYP LE TOP PLATE POST PER PLAN 2'-0" MAX BIRDS MOUTH OPTION 24081-0106 CEILING BY OTHERS S-4.2.0 01/16/2025 STEEL POST TO STEEL BEAM ROOF FRAMING PERPENDICULAR TO ROOF AND MISC FRAMING BEAM BRACE BELOW RAFTERS AS NOTED 10 CONNECTION WALL DETAILS SCALE: NTS 11 SCALE: 1" = 1' 12 SCALE: Permit #: 6327 Permit Date: 01/24/25 Permit Type: RESIDENTIAL ADDITION Project Name: 309 S Dunham Ave Addition Applicant Name: Smith Addition Applicant 19406 327th Ave NE Address: Applicant, City, Duvall, WA 98019 State, Zip: Contact: Garrett Charlson Phone: 425-518-0036 Email: garrett@snovalleycottages.com Scope of Work: Single Story addition to rear of house, reconfigure interior walls at main floor and basement,covered porch addition at front and rear, upgrade insulation, windows, doors, electrical, plumbing and HVAC. Valuation: 250000.00 Square Feet: 384 Number of 1 Stories: Construction VB Type: Occupancy R-3; Residential Group: ID Code: Permit Issued: 04/01/2025 Permit Expires: 02/24/2026 Form Permit RESIDENTIAL ADDITION Type: Status: COMPLETE Assigned To: Kristin Foster Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 100 SINGLE SMITH 00538300201300 309 S DUNHAM AVE FAMILY ANTHONY/HEIDI RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License # A & E Renovations, CONSTRUCTION Morgan Losey 425-248-9121 9001 9th Pl SE COA 604 576 945 LLC CONTRACTOR A & E Renovations, CONSTRUCTION Morgan Losey 425-248-9121 9001 9th Pl SE L&I ERENOER795OT LLC CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status R20. Final inspection approved 12/26/2025 ADDITION/ALTERATION 12/08/2025 12/08/2025 BUILDING Approved per photos provided. FINAL R20. Homeowner will not be Partial 11/25/2025 ADDITION/ALTERATION 11/26/2025 11/26/2025 BUILDING home until after 1:00. Approval FINAL Drywall nail and screw 08/22/2025 Inspection 08/25/2025 08/25/2025 BUILDING Completed inspection Voicemail request AM 08/18/2025 R11. INSULATION however homeowner has 08/19/2025 08/19/2025 BUILDING Approved asked for PM 08/18/2025 R11. INSULATION 08/19/2025 08/19/2025 BUILDING Approved Partial 08/14/2025 C11. INSULATION 08/15/2025 08/15/2025 BUILDING Approval 08/11/2025 R10. FRAMING Rough framing approved 08/12/2025 08/12/2025 BUILDING Approved R08. MECHANICAL 08/06/2025 08/07/2025 08/07/2025 BUILDING Approved ROUGH-IN Not 08/06/2025 R10. FRAMING 08/07/2025 08/07/2025 BUILDING Completed 07/25/2025 R06. SHEARWALL 07/28/2025 07/28/2025 BUILDING Approved Not 05/22/2025 R10. FRAMING AM or PM works 05/23/2025 05/23/2025 BUILDING Completed R02.1 FOOTING 04/22/2025 04/23/2025 04/23/2025 BUILDING Approved DRAINS/DOWNSPOUTS Wall and Footing 04/10/2025 R02. FOOTING 04/11/2025 04/11/2025 BUILDING Approved approved R04. PLUMBING 04/08/2025 04/09/2025 04/09/2025 BUILDING Approved GROUNDWORK Plan Reviews Date Review Type Description Assigned To Review Status No Comment 02/11/2025 RESIDENTIAL ADDITION AIRPORT Received 02/11/2025 RESIDENTIAL ADDITION Approved plans in iWorQ BUILDING Approved Tightline new gutters to downspouts and connect into existing drainage system. Development Approved with 02/11/2025 RESIDENTIAL ADDITION Services Manager Conditions All overhead utilities serving property to be underground. 02/11/2025 RESIDENTIAL ADDITION see note PLANNING Approved 02/11/2025 RESIDENTIAL ADDITION No comments, LT, KDS, & KSS PW-ADMIN-GIS Approved 02/11/2025 RESIDENTIAL ADDITION No comments, JW PW-SEW-REV Approved 02/11/2025 RESIDENTIAL ADDITION No comments, GUS PW-WAT-REV Approved Fees Fee Description Notes Amount Building Plan Review Table 4-2 $1,793.51 Credit Card Service $53.81 Processing/Technology $25.00 Building Permit Table 4-1 $2,759.24 State Surcharge - 1st DU Residential - 1st Unit $6.50 Total $4,638.06 Attached Letters Date Letter Description 03/28/2025 Building Permit 01/24/2025 Web Form - Building Application Payments Date Paid By Description Payment Type Accepted By Amount XBP Conf: 01/27/2025 $1,793.51 221470950 01/27/2025 Anthony Smith 221470950 Hannah Hardwick $53.81 XBP Conf: 03/28/2025 $2,790.74 227132188 Outstanding Balance $0.00 Notes Date Note Created By: If side sewer needs to be moved, a side sewer inspection will be required. Tightline new gutters to downspouts and connect into existing drainage system. 03/28/2025 Kristin Foster All overhead utilities serving property to be underground. Single Story addition to rear of house, reconfigure interior walls at main floor and basement, 01/24/2025 covered porch addition at front and rear, upgrade insulation, windows, doors, electrical, Kristin Foster plumbing and HVAC. 01/24/2025 Need a Residential Zoning Verification application prior to processing for review. Kristin Foster Uploaded Files Date File Name 04/21/2025 25543819-20250327_BLD6327_ApprovedPlans.pdf 04/01/2025 25168256-20250124_BLD6327_IssuedPermit.pdf 02/11/2025 24192102-20250124_BLD6327_StructuralPlans2.pdf 02/11/2025 24192103-20250124_BLD6327_ArchPlans.pdf 02/11/2025 24192104-20250124_BLD6327_WSEC.pdf 02/11/2025 24192105-20250124_BLD6327_WSEC2.pdf 02/11/2025 24192106-20250124_BLD6327_StructuralPlans.pdf 02/11/2025 24192099-20250124_BLD6327_Application.pdf 01/24/2025 db58797bc4909c2d4f2157a3f9f38617_wsu_c3_baseline_addition.pdf