Loading...
HomeMy WebLinkAbout17927 Cambridge Dr_BLD6555_2025 Submittal Split System Cooling 5.0 Ton 5A7A3060A1000A/B NNoottee:: “Graphics in this document are for representation only. Actual model may differ in appearance.” September 2024 55AA77AA33006600AA--SSUUBB--11AA--EENN Outline Drawing Model Base A B C D E F G H J K 943 946 870 152 98 219 86 508 5A7A3060A 4 7/8 5/16 (37-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (20) SOUND POWER LEVEL A-Weighted Sound Full Octave Sound Power [dB] Model Power Level [dB(A)] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 5A7A3060A 71 81 72 69 69 66 60 57 54 Note:Rated in accordance with AHRI Standard 270-2008 *For reference only. 2 5A7A3060A-SUB-1A-EN Product Specifications OUTDOOR UNIT(a) (b) 5A7A3060A1000A/B (a) Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program, which is based on AHRI standard POWER CONNS. - V/PH/HZ(c) 208/230/1/60 210/240. MIN. BRCH. CIR. AMPACITY 30 (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR BR. CIR. PROT. RTG. - MAX. (AMPS) 50 circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on COMPRESSOR DURATION®-SCROLL this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit NO. USED - NO. STAGES 1 - 1 selection current. VOLTS/PH/HZ 208/230/1/60 (e) Use start components only when compressor is found to enter locked rotor condition and will not start or when lights dim at compressor R.L. AMPS(d)- L.R. AMPS 23.3 - 125/23.4 - 134 start. No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. FACTORY INSTALLED Optional kit shown. START COMPONENTS(e) NO (Uses BAYKSKT263) (f) Standard Air - Dry Coil - Outdoor (g) This value approximate. For more precise value see unit nameplate. INSULATION/SOUND BLANKET NO (h) Max. linear length 150 ft.; Max. lift - Suction 50 ft.; Max. lift - Liquid 50 ft. For greater length consult refrigerant piping software Pub. No. COMPRESSOR HEAT NO 32-3312-0* (* denotes latest revision). OUTDOOR FAN PROPELLER DIA. (IN.) - NO. USED 27.5 - 1 TYPE DRIVE - NO. SPEEDS DIRECT - 1 CFM @ 0.0 IN. W.G.(f) 5109 NO. MOTORS - HP 1 - 1/5 MOTOR SPEED R.P.M. 850 VOLTS/PH/HZ 208/230/1/60 F.L. AMPS 1.05 OUTDOOR COIL - TYPE SPINE FIN™ ROWS - F.P.I. 1 - 24 FACE AREA (SQ. FT.) 24.93 TUBE SIZE (IN.) 3/8 REFRIGERANT LBS. - R-454B (O.D. UNIT) (g) 5 LBS., 5 OZ FACTORY SUPPLIED YES LINE SIZE - IN. O.D. GAS(h) 7/8 LINE SIZE - IN. O.D. LIQ. 5/16 CHARGING SPECIFICATIONS SUBCOOLING 10°F DIMENSIONS H X W X D CRATED (IN.) 42.5 x 35 x 38 WEIGHT SHIPPING (LBS.) 246 NET (LBS.) 211 5A7A3060A-SUB-1A-EN 3 Mechanical Specification Options General CCoommpprreessssoorr The outdoor condensing units are factory charged with The compressor features internal over temperature and the system charge required for the outdoor condensing pressure protection. Other features include: Centrifugal unit, ten (10) feet of tested connecting line, and the oil pump and low vibration and noise. smallest rated indoor evaporative coil match. This unit CCoonnddeennsseerr CCooiill is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are The outdoor coil provides low airflow resistance and matched with a wide selection of air handlers and efficient heat transfer. The coil is protected on all four furnace coils that are AHRI certified. The unit is certified sides by louvered panels. to UL 60335-2-40. Exterior is designed for outdoor LLooww AAmmbbiieenntt CCoooolliinngg application. As manufactured, this system has a cooling capacity to Casing 55°F. The addition of an evaporator defrost control Unit casing is constructed of heavy gauge, galvanized permits operation to 40°F. The addition of an steel and painted with a weather-resistant powder evaporator defrost control with TXV permits low paint finish. The corner panels are prepainted. All ambient cooling to 30°F. panels are subjected to our 1,000 hour salt spray test. The addition of the BAYLOAM107A low ambient kit Refrigerant Controls permits ambient cooling to 20°F. Refrigeration system controls include condenser fan, TThheerrmmoossttaattss – Cooling only and heat/cooling (manual compressor contactor and low and high pressure and automatic change over). Sub-base to match switches. A factory supplied, field installed liquid line thermostat and locking thermostat cover. drier is standard. 4 5A7A3060A-SUB-1A-EN About American Standard Heating and Air Conditioning American Standard has been creating comfortable and affordable living environments for more than a century. For more information, please visit www.americanstandardair.com. The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 5A7A3060A-SUB-1A-EN 20 Sep 2024 Supersedes (New) ©2024 American Standard Heating and Air Conditioning Permit #: 6555 Permit Date: 06/13/25 Permit Type: RESIDENTIAL MECHANICAL Project Name: DAVID - MECH PERMIT Applicant Name: CM HEATING INC Applicant Address: 1500 INDUSTRY ST #200 Applicant, City, State, Zip: EVERETT Contact: ILYSE MELLO Phone: 4252590550 Email: PERMITS@CMHEATING.COM Scope of Work: NEW FURNACE AND A/C UNIT REPLACEMENTS Valuation: 15000.00 Square Feet: 2946 Number of Stories: 2 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 06/17/2025 Permit Expires: 12/16/2025 Form Permit Type: RESIDENTIAL MECHANICAL Status: EXPIRED Assigned To: Hannah Hardwick Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 100 SINGLE 00866600001100 17927 CAMBRIDGE DR DAVID LINCOLN FAMILY RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License # 1500 INDUSTRY CONSTRUCTION Plumbing CM HEATING INC 425-259-0550 CMHEAHL750LP ST STE 200 CONTRACTOR Contractor 1500 INDUSTRY CONSTRUCTION Construction CM HEATING INC 425-259-0550 CMHEAHL751W ST STE 200 CONTRACTOR Contractor 1500 INDUSTRY CONSTRUCTION CM HEATING INC 425-259-0550 UBI 605890285 ST STE 200 CONTRACTOR Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Air Cond. Unit ≤ 100 BTU/h Enter # of units $15.00 Forced Air Heat ≤ 100 BTU/h Enter # of units $15.00 Mechanical Base Permit Fee $25.00 Credit Card Service $4.65 Total $159.65 Attached Letters Date Letter Description 06/16/2025 Building Permit 06/13/2025 Web Form- Residential Mechanical Application Payments Date Paid By Description Payment Type Accepted By Amount 06/13/2025 Heidi Lyons 234122075 Hannah Hardwick $4.65 XBP Conf: 06/13/2025 $155.00 234122075 Outstanding Balance $0.00 Notes Date Note Created By: 10/24/2025 Expiration notice sent LaNay Hendrick 06/13/2025 Missing Site plan. Emailing applicant Hannah Hardwick Uploaded Files Date File Name 06/17/2025 26922939-2025_BLD6555_IssuedPermit.pdf 06/16/2025 26908625-Site Plan.pdf 06/13/2025 256cca136dbc2eb1fbce0a2046ab497d_spec_david_mech.pdf 06/13/2025 1f758a02f10f4537d19dcdf79dac15c5_david_-_mech_permit.pdf