Loading...
HomeMy WebLinkAbout18500 Hawksview Dr_BLD6571_2025 CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 18500 HAWKSVIEW DR Permit #: 6571 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 00898300003900 DATE OF ISSUANCE. Scope of Work: like for like ac replacement Valuation: 12500.00 OWNER APPLICANT CONTRACTOR SURMACHEV OLEG/SURMACHEVA Bobs Heating BOB'S HEATING OLGA 18500 HAWKSVIEW DR 14148 NE 190TH STREET 14148 NE 190th St ARLINGTON, WA 98223-4634 WOODINVILLE wa 98072 Woodinville, WA 98072 8008403346 206-378-6723 LIC: BOBSHHA853NQ EXP: 09/07/2025 LIC: 603 522 028 EXP: 07/31/2025 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC #: EXP: LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2021 STORIES: 3 CONST. TYPE: VB DWELLING UNITS: OCC GROUP: R-3; Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 06/23/2025 Applicant Signature Date Building Official Date CONDITIONS 3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated; used of adhesive tapes are prohibited. Adhere to approved equipment. Permit shall be onsite for inspection. Call for final inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 06/23/2025 Processing/Technology $25.00 06/23/2025 Inspection $75.00 06/23/2025 Air Cond. Unit ≤ 100 BTU/h $15.00 06/23/2025 Mechanical Base $25.00 Total Due: $140.00 Total Payment: $140.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail RESIDENTIAL MECHANICAL APPLICATION Community and Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit:  New Installation ✔ Addition/Alteration/Repair  Gas Piping Property Address: 18500 Hawks View Dr Project Valuation: 12500 Lot #: Parcel ID No.: 00898300003900 Preferred Contact:  Owner ✔ Contractor like for like ac replacement Project Description: Owner Name: Oleg Surmachev Home No.: 425-445-1474 Email Address: Cell No.: 18500 Hawks View Dr Arlington Wa 98223 Mailing Address: City: State: Zip: Contractor Name: Bobs Heating Office No.: 800-840-3346 Email Address: lhoneycutt@bobsheating.com Cell No.: Mailing Address: 14148 ne 190th st City: Woodinville State: wa Zip: 98072 BOBSHHA853NQ 09/07/2025 L&I Contractor License Number: Expiration Date: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information ✔ Not Applicable  CSST  Brass  Other Proposed Piping Material:  Black Steel  Galvanized Steel _______________________________________ Proposed Piping Size:  ½”  ⅝”  ¾”  1”  1½”  2” Distance from Meter to furthest Appliance: Total BTU’s of all Appliances: MECHANICAL PERMIT FEES (per unit) Type of Fixture No. of Units Cost per Unit Subtotal Model No. Additional Plan Review fees x $ 75.00 = Air Cond. Unit ≤100Btu/h 1 x $ 15.00 = 15.00 127TAN060 Air Cond. Unit >100Btu/h x $ 25.00 = Air Cond. Unit >500Btu/h x $ 50.00 = Air Handling Units x $ 15.00 = Base Mechanical Fee 1 x $ 25.00 = $ 25.00 Boiler <100Btu/h >3hp x $ 15.00 = Boiler >1 million Btu/h<50hp x $ 25.00 = REV03.2022 Page 1 of 2 MECHANICAL PERMIT FEES (per unit) Boiler >1.5 million Btu/h<50hp x $ 50.00 = Boiler >100Btu/h 3-15hp x $ 15.00 = Boiler >500Btu/h 15-30hp x $ 25.00 = Commercial Hoods -Type I x $ 25.00 = Commercial Hoods -Type II x $50.00 = Diffusers x $ 15.00 = Dryer Ducting x $ 15.00 = Ductwork (drawings required) x $ 25.00 = Evaporative Coolers x $ 15.00 = Exhaust/Ventilation Fans x $ 15.00 = Fireplace/Insert/Stove x $ 15.00 = Forced Air Heat ≤100 Btu/h x $ 15.00 = Forced Air Heat >100 Btu/h x $ 25.00 = Gas Clothes Dryer x $ 15.00 = Gas Fired AC ≤100 Btu/h x $ 15.00 = Gas Fired AC >100 Btu/h x $ 25.00 = Gas Fired AC > 500 Btu/h x $ 50.00 = Gas Piping ≤ 5 units x $ 15.00 = Gas Piping > 5 units (plus <5 units) x $ 2.00 = Heat Exchangers x $ 15.00 = Heat Pump-Condensing Unit x $ 25.00 = Hot Water Heat Coils x $ 15.00 = Miscellaneous Appliance - regulated by $ 15.00 x = mechanical code, not otherwise specified Pkg. Units ≤100btu x $ 25.00 = Pkg. Units >100btu x $50.00 = Range/Cook top-Gas Fired x $ 15.00 = Refrigeration Unit ≤100Btu/h x $ 15.00 = Refrigeration Unit >100Btu/h x $ 25.00 = Refrigeration. Unit >500Btu/h x $ 50.00 = Re-inspection fee x $ 75.00 = Residential Range Hood x $ 15.00 = Unit Heaters ≤ 100 Btu/h x $ 15.00 = Unit Heaters >100 Btu/h x $ 25.00 = VAV Boxes (Variable Air Volume, part of air $ 10.00 x = conditioning system) Wall Heaters - Gas Fired x $ 25.00 = Water Heater - Gas Fired x $ 25.00 = Permit Fee 40.00 Inspection Fee $75.00 Processing/Technology Fee $25.00 Total 140.00 REV2.2020 Page 2 of 2 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY  SCHEMATIC IS TO SCALE  SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated I hereby certify that I am the Owner, Applicant, Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. A final inspection and approval shall be obtained when complete. Signature Print Name Date SAVE PRINT REV2.2020 Page 3 of 3 Permit #: 6571 Permit Date: 06/23/25 Permit Type: RESIDENTIAL MECHANICAL Project Name: Surmachev Applicant Name: Bobs Heating Applicant Address: 14148 NE 190TH STREET Applicant, City, State, Zip: WOODINVILLE wa 98072 Contact: Lucinda Honeycutt Phone: 8008403346 Email: lhoneycutt@bobsheating.com Scope of Work: like for like ac replacement Valuation: 12500.00 Square Feet: 3880 Number of Stories: 3 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 06/24/2025 Permit Expires: 12/23/2025 Form Permit Type: RESIDENTIAL MECHANICAL Status: EXPIRED Assigned To: Hannah Hardwick Property Parcel # Address Legal Description Owner Name Owner Phone Zoning SURMACHEV 100 SINGLE 00898300003900 18500 HAWKSVIEW DR OLEG/SURMACHEVA FAMILY OLGA RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License # Lucinda 14148 NE 190th CONSTRUCTION Labor & BOB'S HEATING 206-378-6723 BOBSHHA853NQ Honeycutt St CONTRACTOR Industries Lucinda 14148 NE 190th CONSTRUCTION BOB'S HEATING 206-378-6723 COA 603 522 028 Honeycutt St CONTRACTOR Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Air Cond. Unit ≤ 100 BTU/h Enter # of units $15.00 Mechanical Base Permit Fee $25.00 Credit Card Service $4.20 Total $144.20 Attached Letters Date Letter Description 06/23/2025 Building Permit 06/23/2025 Web Form- Residential Mechanical Application Payments Date Paid By Description Payment Type Accepted By Amount 06/23/2025 Siu Song 235022797 Hannah Hardwick $4.20 XBP Conf: 06/23/2025 $140.00 235022797 Outstanding Balance $0.00 Notes Date Note Created By: 11/26/2025 sent expiration notice Hannah Hardwick 10/24/2025 Expiration notice sent LaNay Hendrick Uploaded Files Date File Name 06/24/2025 27020964-2025_BLD6571_IssuedPermit.pdf 06/23/2025 8fe01403187d7c3a6d6612ed61f965c2_site_plan.pdf 06/23/2025 444eaed9d43239a490fe155a70a036ac_127ana060_equipment_specs.pdf 06/23/2025 da0c84fc61f1feca3372189ac23e7230_12641972-residential_mechanical.pdf