Loading...
HomeMy WebLinkAbout18030 Cedarbough Loop_BLD6763_2025 JAM54D41 MB 440 Black Module JAM54D41 MB n-type Double Glass Bifacial Modules 26% n-type Bifacial Double Glass Module Linear Performance Warranty × × × × × × × × × × 1.8 8.4 8.4 ISSUE DATE: ISSUE DATE: DATE D'EMISSION: DATE D'EMISSION: SUPERCEDES: SUPERCEDES: REMPLACE: REMPLACE: COVER DIMENSIONS PRODUCT PART NOMINAL SIZE A B C CODE NUMBER (in) (mm) (in) (mm) (in) (mm) (in) (mm) PRODUCT PART NOMINAL SIZE D E VOLUME CODE NUMBER (in) (mm) (in) (mm) (in) (mm) (cu. In) (cu. Cm) PRODUCT PART NOMINAL SIZE GASKET INSERT SCREW M.FEET CODE NUMBER (in) (mm) CODE CODE CODE CODE CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 18030 CEDARBOUGH LOOP Permit #: 6763 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 00738500303900 DATE OF ISSUANCE. Scope of Work: 8.8 kW INSTALLATION OF ROOFTOP MOUNTED PV Valuation: 34283.00 SYSTEM 20 PANELS OWNER APPLICANT CONTRACTOR CAMPBELL ROBERT D & VICKIE W Complete Solar, Inc. Complete Solar PO BOX 1043 1403 N Research Way COLVILLE, WA 99114 Orem, UT, 84097 Orem, UT 84097 (385) 482-0045 385 482 0045 LIC: COMPLSI752L3 EXP: 08/19/2027 LIC: 605-620-806 EXP: 06/30/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC #: EXP: LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: SOLAR INSTALLATION CODE YEAR: 2021 STORIES: 2 CONST. TYPE: VB DWELLING UNITS: OCC GROUP: R-3; Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 12/16/2025 12/11/2025 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved plans Permit shall be onsite for inspections Call for final inspection The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 12/11/2025 Building Plan Review $480.12 12/11/2025 Credit Card Service $14.40 12/11/2025 Processing/Technology $25.00 12/11/2025 Building Permit $727.71 12/11/2025 State Surcharge - 1st DU $6.50 12/11/2025 Credit Card Service $22.78 12/11/2025 Building Plan Review $480.12 12/11/2025 Credit Card Service $14.40 Total Due: $1,771.03 Total Payment: $1,771.03 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail 10/2/2025 Client: Blue Raven Solar 1403 North Research Way, Building J Orem, UT 84097 RE: 8.8kW Solar PV Array Install Structural Certification Letter Campbell Residence 18030 Cedarbough Loop Arlington, WA 98223 AHJ: Arlington To Whom It May Concern: Domus Structural Engineering, LLC. was asked to provide a structural review of the project at the above referenced address for the proposed installation of roof‐mounted solar panels. The scope of this report is strictly limited to the items listed below and based on the building design criteria. Scope of Work: 1. Determine if the existing roof framing is structurally sufficient to support the new PV system in addition to the code required design loads. 2. Evaluate the connection capacity of the proposed racking and system to the existing roof structure. Provided Information: The findings of this report are based on a jobsite evaluation of the existing framing system with the information gathered by Blue Raven Solar as a request of Domus Structural Engineering, LLC. All attached structural calculations are based on the provided information. If roof assembly has been altered since this initial observation, contractor shall notify engineer prior to starting construction. Building Design Criteria: Building Codes and Standards: 2021 IBC/IRC, ASCE 7‐16 Risk Category: II Dead Loads: 9 psf (MP1&2) Roof Live Loads: 20 psf (Live load is removed directly under panels) Wind Speed & Exposure: 110 mph (Vult), Exp C Ground Snow Load: Pg = 25 psf Roof/Sloped Snow Loads: P(roof) = 25 psf Seismic: Seismic check required as Ss >= .4 and SDC is D or greater Framing Description: The below table is a description of the framing based on the information that was provided by Blue Raven Solar: Array Name(s) Slope Framing Description Span Roof Material Metal plate connected pre‐manufactured trusses Composition Shingle with MP1&2 40 spaced at 24 in. o.c. with 2x4 top and bottom chords, 6'‐6" Plywood and Skip Sheathing and 2x4 webs. P.O. Box 560, Broomfield, CO 80038 | projects@domusstruc.com | Page 1 of 9 Framing Results: Below is a summary table of the results of the analysis and a description of upgrades if required. Array Name(s) Results Upgrade (if required) Adequate to support the imposed loading ‐ No MP1&2 None structural upgrades required Anchorage: Below is a summary of the type of connection(s) that is proposed to be used and the allowable spacings. Maximum Spacing Attachment Name Racking Method Fastener Pattern: (Landscape/Portrait) (1) 5/16" dia. lag screw with 2.5 inch min. SFM Infinity Railless 72 in. L / 48 in. P Staggered embedment depth into framing. Where racking method is railless, attachments are located where panels meet. Otherwise, the attachments are connected directly to the rails. Unless noted otherwise, all allowable cantilevers are limited to the maximum attachment spacing divided by 3. (1/3*spacing) Limitations: The scope of this report is strictly limited to an evaluation of the fastener attachment, underlying framing and supporting structure only. All panels, racking and hardware shall be installed per manufacturer specifications and within specified design limitations. All waterproofing shall be provided by the manufacturer. Domus Structural Engineering, LLC assumes no responsibility for misuse or improper installation of the solar PV panels or racking. Please contact me with any further questions or concerns regarding this project. Sincerely, John Calvert, P.E. Domus Structural Engineering, LLC P.O. Box 560, Broomfield, CO 80038 | projects@domusstruc.com | Page 2 of 9 Dead Loads Calculations (MP1&2) Item Load PV System Dead Load Weight 3 psf PV System Dead Load Provided by Client/Manufacturer PV System Dead Load Adjusted to 3.9 psf 40 deg Roof Slope Item Load Composition Shingle 4 psf Plywood and Skip Sheathing 3.5 psf 2x4 Top Chords 0.7 psf Roof Dead Load Vaulted Ceiling ‐ N/A 0 psf Miscellaneous 0.8 psf Total Roof Dead Load 9 psf Roof Dead Load Adjusted to 40 11.7 psf deg Roof Slope P.O. Box 560, Broomfield, CO 80038 | projects@domusstruc.com | Page 3 of 9 Snow Loads Calculations (MP1&2) The snow loads on the standoffs, their attachment, and the underlying structure are determined per the requirements of ASCE 7‐16 Chapter 7 or given directly by the AHJ. Snow Design Parameters: Without PV With PV Ground Snow Load, pg = 25 25 psf Importance Factor, I= 1 1 Thermal Factor, Ct = 1 1.1 Table 7‐3 Exposure Factor, Ce = 1 1 Table 7‐2 Unobstructed Roof Surface Type = All Other Surfaces Slippery Surface Roof Slope Factor, Cs = 0.75 0.50 Fig. 7.4‐1 34 Calculations: = 0.7∙Ce∙Ct∙I∙Pg Eq. 7‐1 Flat Roof Snow Load, pf = 17.5 19.3 psf = Cs∙Pg Eq. 7.4‐1 Sloped Roof Snow Load, Ps = 13.1 9.6 psf Minimum Low‐Slope Roof Snow Load = I∙Pg or 20 psf min Sec. 7.3.4 (if required) = N/A N/A psf Local Minimum Roof Snow Load, pmin AHJ = N/A N/A psf Design Roof Snow Load, proof = 25.0 25.0 psf Sheds Snow No Design Snow Load 25.0 psf *Design snow equals ground snow, snow reductions not permitted per AHJ Lateral (SFM Infinity) 1 Panel Orientation Portrait Landscape Effective/Trib Wind Area (ft2) 22.60 22.30 Roof Slope 40 40 Lateral Snow Load on Standoff 363.2 358.4 (lbs) *See Attachment Capacity Calculations for Demand/Capacity Ratio P.O. Box 560, Broomfield, CO 80038 | projects@domusstruc.com | Page 4 of 9 Wind Loads Calculations (MP1&2) SFM Infinity The wind loads on the standoffs and their attachment to the underlying structure are determined per the requirements for rooftop solar panels parallel to the roof surface (ASCE 7‐16, Section 29.4.4). Wind Design Parameters: Ultimate Wind Speed, (Vult) = 110 mph Local Requirement Risk Category = II Wind Directionality Factor, Kd = 0.85 Table 26.6‐1 Exposure Category = C Topographic Factor, Kzt = 1.00 Table 26.8‐1 Ground Elevation = 0 ft Ground Elevation Factor, Ke = 1.00 Table 26.9‐1 Mean Roof Height, h = 20 ft Velocity Pressure Exposure Coefficient, Kz = 0.90 Table 26.10‐1 Roof Slope = 40 degrees Roof Type = Gable Array Edge Factor, e = 1 Section 29.4.4 Effective Wind Area = Standoff Tributary area (see below) Calculations: Velocity Pressure, q (Ult) = 0.00256∙K ∙K ∙K ∙V2 Eq. 26.10‐1 h z zt e Velocity Pressure, q (Ult) = 0.00256∙K ∙K ∙K ∙K ∙V2 Eq. 26.10‐1 h z zt d e = 23.75 psf Design Wind Pressures, (Ult) = qh∙GCp∙Kd∙e∙a Eq.29.4‐7 Design Wind Pressures, (Ult) = qh∙GCp∙e∙a Eq.29.4‐7 Uplift Downward Panel Orientation Portrait Landscape Both Zone 1 (Interior) 2 (Edge) 3 (Corner) 1 (Interior) 2 (Edge) 3 (Corner) All Standoff spacing x‐ direction (in) 48.0 48.0 32.0 72.0 72.0 48.0 48.0 Standoff spacing y‐ direction (in) 67.8 33.9 33.9 44.6 22.3 22.3 67.8 Effective/Trib Wind Area (ft2) 22.60 11.30 7.53 22.30 11.15 7.43 22.60 Pressure Equalization Factor, a 0.68 0.78 0.80 0.68 0.78 0.80 0.68 External Pressure Coefficient, GCp ‐1.45 ‐1.96 ‐2.62 ‐1.45 ‐1.96 ‐2.62 0.90 Design Wind Pressure (Ult) (psf) ‐23.38 ‐36.39 ‐49.73 ‐23.54 ‐36.56 ‐49.84 16.00 Design Wind Pressure (ASD) (psf) ‐14.03 ‐21.83 ‐29.84 ‐14.13 ‐21.94 ‐29.90 10.00 Dead Load on Attachment (lbs) 67.8 33.9 22.6 66.9 33.5 22.3 67.8 Attachment Net Uplift Forces (ASD) (lbs) ‐276 ‐226 ‐211 ‐275 ‐225 ‐209 267 *See Attachment Capacity Calculations for Demand/Capacity Ratio P.O. Box 560, Broomfield, CO 80038 | projects@domusstruc.com | Page 5 of 9 Attachment Capacity Calculations (MP1&2) SFM Infinity Uplift Calculations Standoff Uplift Check Panel Orientation Portrait Landscape Maximum Design Uplift (ASD)* = 276 lbs 275 lbs Standoff Uplift Capacity (Manufacturer) = 450 lbs 450 lbs Standoff Demand/Capacity Ratio, DCR = 61% 61% Results DCR < 100% Therefore OK DCR < 100% Therefore OK *See Wind Loads Calculations Fastener Uplift Check Panel Orientation Portrait Landscape Maximum Design Uplift (ASD) = 276 lbs 275 lbs Standoff Fastener = 1 ‐ 5/16" Dia. Lag 1 ‐ 5/16" Dia. Lag Number of Fasteners, N = 1 1 Embedment Depth, T = 2.5 in 2.5 in Fastener Allowable Pullout, W = 250 lb/in 250 lb/in Duration of Load Factor (Wind) = 1.6 1.6 Fastener Uplift Capacity = 1000 lbs 1000 lbs Standoff Demand/Capacity Ratio, DCR = 28% 27% Results DCR < 100% Therefore OK DCR < 100% Therefore OK P.O. Box 560, Broomfield, CO 80038 | projects@domusstruc.com | Page 6 of 9 Beam Calculations (MP1&2) PASS Dead Load 11.7 psf Member Size 2x4 PV Load 3.9 psf Lumber Sp/Gr DF#2 Beam Snow Load 25.0 psf Member Spacing 24 in Loading Live Load 20.0 psf MemberSection Mod 3.06 in3 Properties Moment of Inertia 5.36 in4 Slope 40 deg Deflection Criteria Cantilever N/A ft LL L/180 Span 1 6.5 ft TL L/120 Criteria Span 2 N/A ft Creep Factor 1.5 Total Length 6.5 ft Beam Analysis Method Simple Span Governing Load Combo DL + SL Total Load 40.6 psf Criteria: Demand Allowable Units Demand/Allowable Shear 75 207 psi 36.5% OK Bending (+) 1682 1785 psi 94.2% OK Bending (‐) N/A 1785 psi N/A OK AnalysisDeflection: Live 0.399 0.566 in 70.5% OK Total 0.774 0.849 in 91.2% OK NDS 4A Values Cd Cm Ct CL Cf Cfu Cr Ci Allowable Fv (psi) = 180 1.15 1111111 207 Fb+ (psi) = 900 1.15 1 1 1 1.5 1 1.15 1 1785 Fb‐ (psi) = 900 1.15 1 1 1.000 1.5 1 1.15 1 1785 E (psi) = 1600000 11111111 1600000 Emin (psi) = 580000 11111111 580000 P.O. Box 560, Broomfield, CO 80038 | projects@domusstruc.com | Page 7 of 9 Lateral Check of Existing Lateral Force Resisting Systems Per 10% lateral exemption of 2021 IEBC Section 805.3 Existing Roof Seismic Weight Element Unit Weight (psf) Area/Length Weight (lbs) Roof 11.7 3339.0 ft^2 39228.8 Ceiling 6.0 3339.0 ft^2 20034.0 Exterior Walls 11.0 231.1 ft 20340.0 (8' Wall Height Assumed) Interior Walls 8.0 115.6 ft 7396.4 Existing Weight of Affected Building 86999 New PV System Seismic Weight Element Unit Weight (psf) Area (Sq. Ft.) Weight (lbs) PV System 3 420.0 1260.0 Total PV System Weight 1260.0 10% Comparison Element Weight (lbs) 10% of Existing Building Weight (Allowable) 8699.9 Approximate Weight of PV System (Actual) 1260.0 Percent Increase 1.4% Results OK Per the International Existing Building Code (IEBC) 2021 Section 805.3, alterations to a building that result in less than 10% increase in the total weight may be performed without a lateral evaluation of the existing building. The checks above show that the total additional weight added due to the proposed PV array will not increase the total weight of the building by more than 10%, thus qualifying under Section 805.3. P.O. Box 560, Broomfield, CO 80038 | projects@domusstruc.com | Page 8 of 9 Appendix A: General Notes GENERAL ● The contractor shall verify all dimensions, property setbacks, AHJ/HOA CC&R's, elevations and site conditions before starting work and shall notify Domus Structural Engineering, LLC of any discrepancies. ● All report conclusions represent Domus Structural Engineering, LLC's best professional judgment based upon industry standards. ● Resolve any conflicts on the drawings with Domus Structural Engineering, LLC before proceeding with construction. ● The design criteria used for this project & listed on the first page of the report is based on the engineer's best judgement and/or provided by ASCE. AHJ specific requests may differ. Please contact our team if the design criteria needs to be modified. ● A site visit was not physically conducted by Domus Structural Engineering, LLC. The accompanying calculations and certification are provided with the understanding that the site building and construction standards meet an acceptable level of industry standards. It shall be the contractor's responsibility to identify any irregularities such as inconsistent framing conditions, water damage, fire damage, or cracked, split or noticeably deflecting framing members. ● Domus Structural Engineering, LLC is not responsible for enforcing safety measures or regulations. The contractor shall design, construct, and maintain all safety devices including shoring and bracing, and shall be solely responsible for conforming to all local, state and federal safety and health standards, laws and regulations. The contractor shall take necessary precautions to maintain and insure the integrity of the structure during construction. If a lawsuit is filed by one of the contractor's or subcontractor's employees, or anyone else, the contractor will indemnify, defend and hold the owner and Domus Structural Engineering, LLC harmless of any and all such claims. ● Any and all waterproofing shall be provided by the contractor. Domus Structural Engineering, LLC is not responsible for waterproofing. ● All hardware shall be installed per manufacturer specifications and within specified design limitations. Domus Structural Engineering, LLC assumes no responsibility for incorrectly installed hardware or hardware installed outside of the manufacturer specifications. USER RELIANCE ● Domus Structural Engineering, LLC was engaged by Blue Raven Solar (Client) to perform this assessment. This report, and the information therein, are for the exclusive use of the Client. This report has no other purpose and shall not be relied upon, or used, by any other person or entity without the written consent of Domus Structural Engineering, LLC. Third parties that obtain this report or the information within shall have no rights of recourse or recovery against Domus Structural Engineering, LLC, its officers or employees. ROOF MOUNTED ARRAYS ● If an analysis of a supporting structure is included in our scope of work, the structural assessment only applies to the section of the roof that is directly supporting the proposed solar PV system. ● No structural members can be cut for conduit, etc., unless specifically shown. Obtain prior written approval for installation of any additional conduit, etc. ● It is assumed that a standard quality of construction care was used to construct the original building. It shall be the contractor's responsibility to field verify any and all framing members supporting the proposed PV array are in adequate condition. The contractor shall field inspect for sub‐standard construction means, signs of dry rot, mold, fire damage, etc. and notify engineer if any compromised material is found on site prior to starting construction. ● It is assumed that there have been no additional loads (HVAC or MEP equipment, additional layers of roofing, etc) added to the building over the course of the structure's history. The contractor and/or client shall verify this with the property owner and notify Domus Structural Engineering, LLC if additional load has been added to the structure already. ● Flexible utility connections must be used at any building seismic joint. ● Care should be taken to ensure that PV arrays do not preclude drainage of rain water. ● Unless otherwise noted, construction material shall be evenly distributed if placed on framed floors or roofs. Loads shall not exceed the allowable loading for the supporting members and their connections. ● All lags or wood screws at the roof shall be stainless steel and installed within the middle 1/3 of the dimensional width of the framing members. ● All fasteners shall be a minimum of 6" away from any truss panel or hinge joints, truss plates and/or member ends. Field verify location of fasteners prior to starting construction. All fasteners shall be pre‐drilled to avoid splitting existing lumber. ● Unless otherwise noted, all lags installed in underlying roof framing members shall be embedded (threaded embed) a minimum of 2.5'' into the underlying framing. ● Domus Structural Engineering, LLC is not responsible for downslope effects of snow shedding or sliding off of the PV array nor any damage to downslope decks, roofs, walkways, landscaping, automobiles, pets, people, etc.. If snow guards are requested by the customer, notify Domus Structural Engineering, LLC. P.O. Box 560, Broomfield, CO 80038 | projects@domusstruc.com | Page 9 of 9 Permit #: 6763 Permit Date: 10/08/25 Permit Type: SOLAR INSTALLATION Project Name: Robert Campbell PV Applicant Name: Complete Solar, Inc. Applicant Address: 1403 N Research Way Applicant, City, State, Zip: Orem, UT, 84097 Contact: Dolly Ann Palonpon Phone: (385) 482-0045 Email: permitting.department@blueravensolar.com Scope of Work: 8.8 kW INSTALLATION OF ROOFTOP MOUNTED PV SYSTEM 20 PANELS Valuation: 34283.00 Square Feet: 420 Number of Stories: 2 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 10/13/2025 Permit Expires: 04/12/2025 Form Permit Type: SOLAR INSTALLATION Status: COMPLETE Assigned To: LaNay Hendrick Property Parcel # Address Legal Description Owner Name Owner Phone Zoning CAMPBELL 100 SINGLE 18030 CEDARBOUGH 00738500303900 ROBERT D & FAMILY LOOP VICKIE W RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License # CONSTRUCTION Complete Solar Robert Campbell 385 482 0045 L and I COMPLSI752L3 CONTRACTOR CONSTRUCTION Complete Solar Robert Campbell 385 482 0045 COA 605-620-806 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 12/15/2025 S00. SIGN FINAL 12/16/2025 12/16/2025 BUILDING Approved Plan Reviews Date Review Type Description Assigned To Review Status 10/09/2025 SOLAR INSTALLATION BUILDING Approved 12/03/2025 SOLAR INSTALLATION BUILDING Approved Fees Fee Description Notes Amount Building Plan Review Table 4-2 $480.12 Credit Card Service $14.40 Processing/Technology $25.00 Building Permit Table 4-1 $727.71 State Surcharge - 1st DU Residential - 1st Unit $6.50 Credit Card Service $22.78 Building Plan Review Table 4-2 $480.12 Credit Card Service $14.40 Total $1,771.03 Attached Letters Date Letter Description 12/11/2025 Building Permit 10/08/2025 Web Form - Building Application Payments Date Paid By Description Payment Type Accepted By Amount 10/09/2025 BRS Permitting cc LaNay Hendrick $14.40 XBP Conf: 10/09/2025 $480.12 245376430 10/13/2025 Permitting BRS cc LaNay Hendrick $22.78 XBP Conf: 10/13/2025 $759.21 245683618 12/03/2025 BES Permitting cc LaNay Hendrick $14.40 XBP Conf: 12/03/2025 $480.12 250710617 Outstanding Balance $0.00 Notes Date Note Created By: 12/03/2025 applicant sent in revisions- routed again for review LaNay Hendrick Uploaded Files Date File Name 12/16/2025 29941680-Building+Permit-Signed12.16.2025.pdf 11/18/2025 29497981-Robert Campbell PBa Permit Pack Stamped Flat.pdf 11/18/2025 29497976-Robert Campbell PB Revision Letter.pdf 10/08/2025 bc5f516f7d142220c7855290717f7eda_campbell_arlington_wa_stamped_compressed.pdf 10/08/2025 aea9c2e9a03017e758af259d6041defc_solar_permit_application_compressed.pdf 10/08/2025 6da93529a5a140142b8dd0d4d811f2db_pp_2486_fd_5820_-_permit_pack_-_robert_campbell_stamped_compressed.pdf CORRECTION AMENDMENT Date: 11/03/2025 Permit #: Project Name: Robert Campbell Address: 18030 Cedarbough loop Arlington, WA 98223 To whom it may concern, All pages have been updated to show a module change to JA Solar 440s. Please reach out to me directly if you have any questions. Jared Sorensen Thor Snell Quality Control Technician Quality Control Manager Jared.Sorensen@sunpower.com Zachary.Snell@sunpower.com Quality.control@blueravensolar.com Quality.control@blueravensolar.com 385-273-1105 385-273-1105 JAM54D41 MB 440 Black Module JAM54D41 MB n-type Double Glass Bifacial Modules 26% n-type Bifacial Double Glass Module Linear Performance Warranty × × × × × × × × × × 1.8 8.4 8.4 ISSUE DATE: ISSUE DATE: DATE D'EMISSION: DATE D'EMISSION: SUPERCEDES: SUPERCEDES: REMPLACE: REMPLACE: COVER DIMENSIONS PRODUCT PART NOMINAL SIZE A B C CODE NUMBER (in) (mm) (in) (mm) (in) (mm) (in) (mm) PRODUCT PART NOMINAL SIZE D E VOLUME CODE NUMBER (in) (mm) (in) (mm) (in) (mm) (cu. In) (cu. Cm) PRODUCT PART NOMINAL SIZE GASKET INSERT SCREW M.FEET CODE NUMBER (in) (mm) CODE CODE CODE CODE RESIDENTIAL PHOTOVOLTAIC SOLAR PANEL Community and Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 The City of Arlington requires a building permit to install Photovoltaic (PV) Solar Panel(s) for residential and commercial uses. This policy governs Residential uses only. Other permits may be required per Washington State Labor and Industries or Utility Providers. SUBMIT ELECTRONIC FILES FOR EACH OF THE FOLLOWING: REQUIRED DOCUMENTS City of Arlington Solar Panel Application Roof Plan and Construction Documents Manufacturer’s installation specifications Engineering, (if required) Type of Permit: New Installation Addition Replacement Property Address: 18030 Cedarbough loop, Arlington, Washington, 98223 Project Valuation: 34283 Lot #: 39 Parcel ID No.: 00738500303900 Subdivision: Project Scope of Work: 8.8 kW PV Solar Panel Installation on Roof Primary Contact: Owner Contractor Owner Name: Robert Campbell Home No.: Email Address: rdc.campbell@gmail.com Cell No.: 5096753017 18030 Cedarbough loop Arlington WA 98223 Mailing Address: City: State: Zip: Contractor Name: Complete Solar, Inc. Office No.: Email Address: permitting.department@blueravensolar.com Cell No.: 385-482-0045 Mailing Address: 1403 N Research Way City: Orem State: UT Zip: 84097 L&I Contractor License Number: COMPLSI759K9 Expiration Date: 06/05/27 Existing Roof Structure: Existing Roof Material: Comp Shingle 3339.67 2 Building Square Footage: Number of Stories: INSPECTION REQUIREMENTS Roof mount panels require two (2) inspections minimum 1. The first inspection is for the roof mount racking hardware to verify compliance and attachment. (You may schedule this inspection for the day the panels are being installed. You may begin mounting panels over the racking prior to inspection but there must be enough racking exposed for the inspector to verify compliance.) 2. The final inspection shall be scheduled when the project is complete and after Labor and Industries has approved the electrical. I hereby certify that I am the Owner Contractor and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. Permitting Coordinator DOLLY ANN PALONPON 10 / 08 / 2025 Signature Print Name Date SAVE PRINT RESIDENTIAL ROOFTOP SOLAR PERMIT PACKAGE BLUE RAVEN Robert Campbell Enphase SOLAR 18030 Cedarbough loop Platinum 1403 N 630 E PV Installation Installer Orem, Utah 84097 Professional Arlington, Washington 98223 (800) 377-4480 BlueRavenSolar.com Cecil Lopeman (509) 675-3017 #042013-75 SCOPE OF WORK SHEET INDEX INSTALLATION OF ROOFTOP MOUNTED PV1 COVER SHEET PHOTOVOLTAIC SOLAR SYSTEM PV2 SITE PLAN PV3 ROOF PLAN PV4 STRUCTURAL PV5 ELECTRICAL 3-LINE PV6 ELECTRICAL CALCULATIONS PV7 LABELS PV8 PLACARD SS SPEC SHEETS City of Arlington WA Robert Campbell18030 Cedarbough loop Arlington, Washington 98223 CEC-AC SYSTEM SIZE: 8.061 kW AC Snohomish County Public Utilities District (PUD) TYPICAL STRUCTURAL INFORMATION NEW PV SYSTEM INFORMATION TOTAL PV DC SYSTEM SIZE TOTAL PV AC SYSTEM SIZE ROOF MATERIAL: Comp Shingle DC SYSTEM SIZE: 8.8 kW DC CUSTOMER NAME: AHJ: UTILITY COMPANY: SHEATHING: SKIP 8.800 kW DC 6.400 kW AC PROJECT ID: AC SYSTEM SIZE: 6.4 kW AC FRAMING: Manufactured Truss MODULE TYPE: (20) Silfab Solar SIL-440 QD 1442319 RACKING: UNIRAC SFM INFINITY DESIGN CRITERIA ROOF ATTACHMENT: UNIRAC SFM INFINITY FLASHKIT INVERTER TYPE: (20) Enphase IQ8MC-72-M-US PV DC SYSTEM SIZE: WIND SPEED: 110 mph 8.800 kW DC TOTAL ATTACHMENTS: 44 WIND EXPOSURE FACTOR: C PV AC SYSTEM SIZE: SEISMIC DESIGN CATEGORY: D 6.400 kW AC GENERAL NOTES RISK CATEGORY: II REVISIONS: GROUND SNOW LOAD: 25 psf A B WEATHER STATION DATA C WEATHER STATION: BOEING FLD KING CO D HIGH TEMP 2% AVG: 29°C DRAWN BY: EXTREME MINIMUM TEMP: -7°C McKay Ashton PLOT DATE: AHJ APPLICABLE CODES October 2, 2025 City of Arlington WA *2023 NATIONAL ELECTRIC CODE (NEC) DRAWING TITLE: *2021 INTERNATIONAL BUILDING CODE (IBC) *2021 INTERNATIONAL RESIDENTIAL CODE (IRC), 2021 UNIFORM PLUMBING Cover Sheet CODE (UPC), AND ALL STATE AND LOCAL BUILDING, ELECTRICAL, AND UTILITY COMPANY PLUMBING CODES DRAWING NUMBER: 10/2/2025 Snohomish County Public Utilities District (PUD) PV1 FRONT OF HOME 18030 Cedarbough loop BLUE RAVEN SOLAR 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com M AC CB MSP DC AC DC DC AC AC DC AC DC DC AC AC City of Arlington WA DC DC AC AC Robert Campbell18030 Cedarbough loop DC DC AC AC Arlington, Washington 98223 DC DC DC AC AC AC DC AC DC DC DC Snohomish County Public Utilities District (PUD) AC AC AC DC DC DC AC AC AC CUSTOMER NAME: AHJ: UTILITY COMPANY: PROJECT ID: 1442319 PV DC SYSTEM SIZE: 8.800 kW DC PV AC SYSTEM SIZE: 6.400 kW AC REVISIONS: A 10/2/2025 B SITE PLAN C SCALE: 3/32" = 1'-0" D DRAWN BY: LEGEND PV SYSTEM SPECIFICATIONS COMPASS McKay Ashton BREAKER FIRE SETBACK TRENCH OR NEW PV SYSTEM INFORMATION PLOT DATE: M UTILITY METER BE ENCLOSURE BAT ESS - BATTERY HATCH OVERHEAD PV MODULE: (20) Silfab Solar SIL-440 QD, POWER RATING: 440 W N E October 2, 2025 INVERTER: (20) Enphase IQ8MC-72-M-US, POWER RATING: 320 W DRAWING TITLE: MAIN SERVICE DC MSP AC AC DISCONNECT ESC ESS - CONTROLLER AC MICROINVERTER PROPERTY LINE PANEL Site Plan PV PRODUCTION REMOTE POWER ROOF TOP SUB SUBPANEL PV RPO DRAWING NUMBER: METER OFF SWITCH JUNCTION BOX ICONS WITH DOTTED OUTLINE UTILITY METER GENERATOR INDICATE INTERIOR LOCATION W S CT CB COMBINER BOX ATS INV INVERTER PV2 CT CABINET ATS PANEL BLUE RAVEN UNDERGROUND SERVICE LINE FRONT OF HOME SOLAR SKYLIGHT 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com M AC CB 3' POINT OF INTERCONNECTION 3' SKYLIGHT MSP DC AC DC DC AC AC DC AC DC DC 3' AC AC DC DC 1'-6" AC AC 1'-6" 1'-6" DC DC 1'-6" AC AC City of Arlington WA 3' Robert Campbell18030 Cedarbough loop Arlington, Washington 98223 DC DC DC AC AC AC DC 3' AC DC DC DC AC MP1 AC AC Snohomish County Public Utilities District (PUD) 3' MODULE QTY: 10 DC DC DC AC AC AC AZIMUTH: 270 PITCH: 40 CUSTOMER NAME: AHJ: UTILITY COMPANY: TSRF: 81 PROJECT ID: AREA: 453 ft² MP2 SKYLIGHT CHIMNEY 1442319 MODULE QTY: 10 PV DC SYSTEM SIZE: AZIMUTH: 224 8.800 kW DC PITCH: 40 PV AC SYSTEM SIZE: 6.400 kW AC TSRF: 94 AREA: 494 ft² REVISIONS: A B ROOF PLAN C SCALE: 1/8" = 1'-0" 10/2/2025 D DRAWN BY: LEGEND PV SYSTEM SPECIFICATIONS COMPASS McKay Ashton BREAKER FIRE SETBACK TRENCH OR NEW PV SYSTEM INFORMATION PLOT DATE: M UTILITY METER BE ENCLOSURE BAT ESS - BATTERY HATCH OVERHEAD PV MODULE: (20) Silfab Solar SIL-440 QD, POWER RATING: 440 W N E October 2, 2025 INVERTER: (20) Enphase IQ8MC-72-M-US, POWER RATING: 320 W DRAWING TITLE: MAIN SERVICE DC MSP AC AC DISCONNECT ESC ESS - CONTROLLER AC MICROINVERTER PROPERTY LINE PANEL Roof Plan PV PRODUCTION REMOTE POWER ROOF TOP SUB SUBPANEL PV RPO DRAWING NUMBER: METER OFF SWITCH JUNCTION BOX ICONS WITH DOTTED OUTLINE UTILITY METER GENERATOR INDICATE INTERIOR LOCATION W S CT CB COMBINER BOX ATS INV INVERTER PV3 CT CABINET ATS PANEL STRUCTURAL INFORMATION CEILING JOIST/ MAXIMUM MAXIMUM PRIMARY PV ARRAY AREA (ft²) 419.98 PANEL AZIMUTH PITCH TSRF AREA FRAMING SIZE ROOF MATERIAL SHEATHING TYPE FRAMING TYPE PURLINS SIZE RACKING TYPE ATTACHMENT TYPE ATTACHMENT CANTILEVER PRIMARY ROOF AREA (ft²) 3339.67 COUNT (DEG) (DEG) (%) (ft²) AND SPACING AND SPACING SPACING (S) (C) PRIMARY ROOF COVERAGE (%) 12.58 MP1 10 270 40 81 453 Comp Shingle SKIP Manufactured Truss 2x4 @ 24 in OC 2x4 @ 24 in OC UNIRAC SFM INFINITY UNIRAC SFM INFINITY FLASHKIT 72''L / 48''P 24''L / 16''P SECONDARY PV ARRAY AREA (ft²) MP2 10 224 40 94 494 Comp Shingle SKIP Manufactured Truss 2x4 @ 24 in OC 2x4 @ 24 in OC UNIRAC SFM INFINITY UNIRAC SFM INFINITY FLASHKIT 72''L / 48''P 24''L / 16''P * IF APPLICABLE SECONDARY ROOF AREA (ft²) BLUE RAVEN MP3 0 SECONDARY ROOF COVERAGE (%) SOLAR MP4 0 TOTAL PV ARRAY WEIGHT (lbs) 926 MP5 0 TOTAL PV ATTACHMENTS 44 MP6 0 POINT LOAD (lbs/att.) 21 1403 N 630 E MP7 0 DISTRIBUTED LOAD (psf) 2.2 Orem, Utah 84097 MP8 0 (800) 377-4480 MP9 0 BlueRavenSolar.com MP10 0 ATTACHMENT TYPE: PV MODULES SHALL NOT EXTEND Unirac SFM Infinity ABOVE ROOF RIDGE LINE PV MODULE MAX CANTILEVER PER TABLE ABOVE PV MODULES SHALL NOT EXTEND MORE THAN (C) 6 INCHES FROM THE PLANE OF THE ROOF UNIRAC UNIRAC PV MODULE SFM INFINITY SFM INFINITY 2" MICRORAIL 6.5" SPLICE ROOF MATERIAL NOT EXISTING FRAMING SHOWN FOR CLARITY 2 12 " MIN. (1) 5/16" LAG BOLT EMBEDMENT WITH EPDM WASHER City of Arlington WA ATTACHMENT SPACING Robert Campbell18030 Cedarbough loop PER TABLE ABOVE Arlington, Washington 98223 FRAMING SPACING PER TABLE ABOVE *THIS DETAIL IS NOT MEANT TO BE 1 FRAMING DETAIL EXTERIOR WALL AN EXACT REPRESENTATION OF 2 ATTACHMENT DETAIL SCALE: 1/2" = 1'-0" FRAMING OR PV MODULE LAYOUT SCALE: 1-1/2" = 1'-0" Snohomish County Public Utilities District (PUD) RIDGE NOTES LANDSCAPE PORTRAIT CUSTOMER NAME: AHJ: UTILITY COMPANY: PROJECT ID: 1442319 PV DC SYSTEM SIZE: 8.800 kW DC PV AC SYSTEM SIZE: 6.400 kW AC REVISIONS: A B C D DRAWN BY: McKay Ashton PLOT DATE: 10/2/2025 October 2, 2025 DRAWING TITLE: Structural FOLLOW ATTACHMENT SPACING IN TABLE ABOVE EAVE DRAWING NUMBER: *ATTACHMENT PATTERN SHOULD BE ATTACHMENT PATTERN STAGGERED UNLESS OTHERWISE 3 SCALE: 1/4" = 1'-0" NOTED IN ENGINEERING LETTER PV4 L1 (1) 8 AWG THHN/THWN-2 CU BLACK L1 (2) 10 AWG THHN/THWN-2 CU BLACK 3/4 INCH L1 (1) 10 AWG THHN/THWN-2 CU BLACK 3/4 INCH L1 (1) 12 AWG THHN/THWN-2 CU BLACK L2 (1) 8 AWG THHN/THWN-2 CU RED L2 (2) 10 AWG THHN/THWN-2 CU RED EMT* L2 (1) 10 AWG THHN/THWN-2 CU RED * L2 (1) 12 AWG THHN/THWN-2 CU RED 4 N (1) 8 AWG THHN/THWN-2 CU WHITE 3 G (1) 10 AWG THHN/THWN-2 CU GREEN 2 G (1) 10 AWG THHN/THWN-2 CU GREEN 1 G (1) 6 AWG BARE, CU G (1) 10 AWG THHN/THWN-2 CU GREEN *TYPE UF CABLE MAY BE SUBSTITUTED FOR USE IN CONDUIT WHERE *TYPE NM (ROMEX) OR UF CABLE IS PERMITTED FOR INTERIOR OR 3/4 INCH EMT Exterior ELECTRICAL CODE PERMITS ATTIC RUNS AND SHALL BE USED WHEN ELECTRICAL CODE PERMITS ENPHASE Q-CABLE, 2-WIRE, FREE AIR Exterior BLUE RAVEN SOLAR 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com PRIMARY PV COMBINER BOX E PRIMARY STRUCTURE 1 A (20) PV MODULES AC DISCONNECT B & MICROINVERTERS SAFETY SWITCH (N) 20A D C Utility Meter (E) 200A Main Service Panel 60A NON-FUSIBLE PV ARRAY 1 PV CIRCUIT 1 F 5 10 MODULES GATEWAY 2 1 15A (N) 20A (E) 200A PV ARRAY 2 PV CIRCUIT 2 (EL) 10 MODULES G N 3 2 1 (EL) G L1 L2 98223 N (EL) G G 4 4 (EL) (PV) 35A Washington N , E City of Arlington WA G Robert Campbell18030 Cedarbough loop Arlington UNDERGROUND SERVICE 120/240 VAC, 60 Hz 9 1 PHASE, 3 WIRE Snohomish County Public Utilities District (PUD) INTERCONNECTION NOTES Utility Meter Number: 29612863 Load Side Breaker in MSP, Interior POI. CUSTOMER NAME: AHJ: UTILITY COMPANY: PROJECT ID: LEGEND (E) EXISTING (PV) PV BREAKER 1442319 (N) NEW (FIB) FACTORY INSTALLED BREAKER (EL) EXISTING LOADS SPD SURGE PROTECTIVE DEVICE PV DC SYSTEM SIZE: (RL) RELOCATED LOADS MI MECHANICAL INTERLOCK 8.800 kW DC PV AC SYSTEM SIZE: EQUIPMENT NOTES EQUIPMENT DESCRIPTIONS 6.400 kW AC FINAL CONFIGURATION OF PV CIRCUITS TO BE DECIDED BY INSTALLER. MUST COMPLY WITH MAX A PV MODULE: Silfab Solar SIL-440 QD, 440 W DC, UL 1703 / UL 61730 COMPLIANT 1 MICROINVERTERS PER CIRCUIT AS LISTED ON ATTACHED SPEC SHEET. REVISIONS: B MICROINVERTER: ENPHASE IQ8MC-72-M-US, 320 W AC (0.320 kW), 1 PHASE, UL 1741 COMPLIANT 2 C ROOFTOP JUNCTION BOX: EZ SOLAR JB-1.2 JUNCTION BOX A D JUNCTION BOX: PVC 4 X 4 JUNCTION BOX 3 B E PV COMBINER BOX: ENPHASE COMBINER 5 (X-IQ-AM1-240-5) F SQUARE-D SAFTEY SWITCH 60A, 2P, 240VAC, NON-FUSIBLE (DU222RB) C 4 G D 5 H DRAWN BY: I 6 J McKay Ashton K PLOT DATE: 7 L October 2, 2025 8 M DRAWING TITLE: N OTHER NOTES Electrical 9 GROUNDING ELECTRODE SYSTEM SHALL BE IN ACCORDANCE WITH NEC 250.53. O P 3-Line 10 Q DRAWING NUMBER: 11 R S ALL INTERIOR CONDUIT MUST BE SCH 80 PVC. 12 T PV5 ELECTRICAL INFORMATION PV BREAKER BACKFEED CALCULATIONS DESIGN LOCATION UTILITY ELECTRICAL SYSTEM "120% RULE" AND TEMPERATURES BLUE RAVEN 1-Phase, 3-Wire, 60Hz, 120/240V (BUSBAR RATING * 120%) - OCPD RATING = AVAILABLE BACKFEED SOLAR DATA SOURCE ASHRAE Weather Station Data MAIN SERVICE NEW PV SYSTEM SUBPANEL 1 SUBPANEL 2 STATE Washington 1403 N 630 E PANEL 1-Phase, 3-Wire, 60Hz, 120/240V CITY Arlington Orem, Utah 84097 BUSBAR RATING 200A ----A ----A AC SYSTEM SIZE 6.4kW AC WEATHER STATION BOEING FLD KING CO PANEL OCPD RATING 200A ----A ----A (800) 377-4480 DC SYSTEM SIZE 8.8kW DC HIGH TEMP 2% AVG 29°C AVAILABLE BACKFEED (120% RULE) 40A ##A ##A PV MODULES EXTREME MINIMUM TEMP -7°C BlueRavenSolar.com PV BREAKER RATING 35A 35A 35A QUANTITY 20 *THESE CALCULATIONS ARE ONLY APPLICABLE IF PV INTERCONNECTION IS A TYPE Silfab Solar SIL-440 QD LOAD SIDE BREAKER. *PV BREAKER MUST BE RATED LESS THAN OR EQUAL TO WATTAGE 440W DC AVAILABLE BACKFEED FOR CODE COMPLIANCE* INVERTERS TYPE Enphase IQ8MC-72-M-US OUTPUT CURRENT 1.33A AC NOMINAL VOLTAGE 240V AC OUTPUT POWER 320W AC WIRE SIZE SPECIFICATIONS 1 2 3 4 5 6 7 8 9 10 MINIMUM CONDUCTOR AMPACITY 16.63A AC 16.63A AC 16.63A AC 33.25A AC ----A AC ----A AC ----A AC ----A AC ----A AC ----A AC 98223 CONDUCTOR MATERIAL CU CU CU CU ---- ---- ---- ---- ---- ---- CONDUCTOR TYPE THHN/THWN-2 THHN/THWN-2 THHN/THWN-2 THHN/THWN-2 ---- ---- ---- ---- ---- ---- CONDUCTOR SIZE 12 AWG 10 AWG 10 AWG 8 AWG ---- CONDUCTOR AMPACITY 30A 40A 40A 55A ----A ----A ----A ----A ----A ----A AMBIENT TEMPERATURE ADJUSTMENT FACTOR 1 1 1 1 ---- ---- ---- ---- ---- ---- CONDUIT FILL ADJUSTMENT FACTOR 1 1 0.8 1 ---- ---- ---- ---- ---- ---- ADJUSTED CONDUCTOR AMPACITY 30A 40A 32A 55A ----A ----A ----A ----A ----A ----A Washington WIRE RUN DISTANCE (FT) 66 65 20 30 ---- ---- ---- ---- ---- ---- , CALCULATED VOLTAGE DROP 0.78% 0.89% 0.27% 0.52% 0% 0% 0% 0% 0% 0% PV CIRCUIT SPECIFICATIONS City of Arlington WA PRIMARY STRUCTURE DETACHED STRUCTURE Robert Campbell18030 Cedarbough loop CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CIRCUIT 5 CIRCUIT 6 CIRCUIT 7 CIRCUIT 8 CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CIRCUIT 5 Arlington NUMBER OF MODULES PER CIRCUIT 10 10 0 0 0 0 0 0 0 0 0 0 0 RATED AC OUTPUT CURRENT (IOUT) 13.3A 13.3A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A MINIMUM AMPACITY (IOUT x 125%) 16.6A 16.6A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A OVERCURRENT PROTECTION RATING 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A COMBINED AC OUTPUT CURRENT (COUT) 26.6A 0.0A MINIMUM AMPACITY (COUT x 125%) 33.3A 0.0A Snohomish County Public Utilities District (PUD) COMBINED PV BREAKER RATING 35AA 0AA TOTAL PV CUSTOMER NAME: AHJ: UTILITY COMPANY: VOLTAGE DROP PROJECT ID: VOLTAGE DROP 1442319 WIRE TAG #1 0.78% WIRE TAG #2 0.89% PV DC SYSTEM SIZE: WIRE TAG #3 0.27% 8.800 kW DC WIRE TAG #4 0.52% WIRE TAG #5 0% PV AC SYSTEM SIZE: WIRE TAG #6 0% 6.400 kW AC TOTAL 2.460000% REVISIONS: A B C D DRAWN BY: McKay Ashton PLOT DATE: October 2, 2025 DRAWING TITLE: Electrical Calculations DRAWING NUMBER: PV6 WARNING LABELS BLUE RAVEN SOLAR UTILITY METER MAIN SERVICE PANEL PV AC DISCONNECT 1403 N 630 E Orem, Utah 84097 (800) 377-4480 PHOTOVOLTAIC SYSTEM BlueRavenSolar.com ! AC DISCONNECT ! RATED AC OUTPUT CURRENT 26.6 A NOMINAL OPERATING AC VOLTAGE 240 V ! WARNING ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED PV COMBINER BOX IN THE OPEN POSITION SOLAR PV SYSTEM EQUIPPED NET METER WITH RAPID SHUTDOWN RAPID SHUTDOWN SWITCH 98223 TURN RAPID SHUTDOWN FOR SOLAR PV SYSTEM PHOTOVOLTAIC SYSTEM SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM SOLAR ELECTRIC PV PANELS COMBINER PANEL AND REDUCE SHOCK HAZARD IN THE ARRAY. ! WARNING AUTHORIZED PERSONNEL ONLY DO NOT ADD LOADS Washington , NO DC WIRES PRESENT RAPID SHUTDOWN TEST NOT REQUIRED City of Arlington WA Robert Campbell18030 Cedarbough loop Arlington Snohomish County Public Utilities District (PUD) CUSTOMER NAME: AHJ: UTILITY COMPANY: PROJECT ID: ! CAUTION 1442319 MULTIPLE SOURCES OF POWER PV DC SYSTEM SIZE: POWER TO THIS BUILDING IS ALSO 8.800 kW DC SUPPLIED FROM A ROOF MOUNTED SOLAR ARRAY. PV DISCONNECT IS PV AC SYSTEM SIZE: LOCATED WITHIN 10 FT AND LINE OF SIGHT OF UTILITY METER. 6.400 kW AC REVISIONS: A B ! WARNING C DUAL POWER SUPPLY ! WARNING D SOURCES: UTILITY GRID AND POWER SOURCE PV SOLAR ELECTRIC SYSTEM DRAWN BY: OUTPUT CONNECTION McKay Ashton DO NOT RELOCATE THIS OVERCURRENT DEVICE PLOT DATE: NOTICE October 2, 2025 *LABEL INSTALLED IN CASE OF EMERGENCY, NEXT TO PV BREAKER DRAWING TITLE: PLEASE CONTACT: Warning BLUE RAVEN SOLAR (800) 377-4480 Labels DRAWING NUMBER: PV7 ELECTRICAL SPECIFICATIONS 440 BLUE RAVEN Test Conditions STC NOCT ]ILAR Module Power (Pmax) Wp 440 328.0 Maximum power voltage (Vpmax) V 33.41 31.17 Maximum power current (Ipmax) A 13.17 10.52 Open circuit voltage (Voc) V 38.97 36.64 NTC Short circuit current (Isc) A 14.22 11.44 Module efficiency % 22.6% Maximum system voltage (VDC) V 1000 SIL-440 QD Series fuse rating A 25 Power Tolerance Wp 0 to +10 Measurement conditions: STC 1000 W/m² • AM 1.5 • Temperature 25 °C • NOCT 800 W/m² • AM 1.5 • Measurement uncertainty ≤ 3% Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by ±5% and power by 0 to +10 W. MECHANICAL PROPERTIES / COMPONENTS METRIC IMPERIAL Module weight 21 kg ± 0.2 kg 46.3 lbs ± 0.4 lbs Dimensions (H x L x D) 1721 mm x 1133 mm x 35 mm 67.8 in x 44.6 in x 1.37 in Maximum surface load (wind/snow)* 4000 Pa rear load / 5400 Pa front load 83.5 lb/ft2 rear load / 112.8 lb/ft2 front load Hail impact resistance ø 25 mm at 83 km/h ø 1 in at 51.6 mph 108 Half cells - N-Type Silicon solar cell 108 Half cells - N-Type Silicon solar cell Cells 182 mm x 91 mm 7.16 in x 3.58 in 3.2 mm high transmittance, tempered, 0.126 in high transmittance, tempered, Glass antireflective coating antireflective coating Cables and connectors (refer to installation manual) 1350 mm, ø 5.7 mm, MC4 from Staubli 53.1 in, ø 0.22 in (12 AWG), MC4 from Staubli High durability, superior hydrolysis and UV resistance, multi-layer dielectric film, Backsheet fluorine-free PV backsheet Frame Anodized aluminum (Black) Junction Box UL 3730 Certified, IEC 62790 Certified, IP68 rated, 3 diodes TEMPERATURE RATINGS WARRANTIES Temperature Coefficient Isc 0.04 %/°C Module product workmanship warranty 25 years** Temperature Coefficient Voc -0.24 %/°C Linear power performance guarantee 30 years Temperature Coefficient Pmax -0.29 %/°C ≥ 98% end 1st yr ≥ 94.7% end 12th yr NOCT (± 2 °C) 45 °C ≥ 90.8% end 25th yr Operating temperature -40/+85 °C ≥ 89.3% end 30th yr CERTIFICATIONS SHIPPING SPECS UL 61215, UL 61730, CSA C22.2#61730, IEC 61215, IEC 61730, IEC 61701 (Salt Mist Modules Per Pallet: 26 or 26 (California) Corrosion), IEC 62716 (Ammonia Corrosion), CEC Listed, UL Fire Rating: Type 2 Product Pallets Per Truck 32 or 30 (California) Factory ISO9001:2015 Modules Per Truck 832 or 780 (California) * Warning. Read the Safety and Installation Manual for mounting specifications and before handling, installing and operating modules. ** 12 year extendable to 25 years subject to registration and conditions outlined under “Warranty” at silfabsolar.com. PAN files generated from 3rd party performance data are available for download at: silfabsolar.com/downloads. Side 67.8" [1721mm] 1.4" [35mm] 11.8" [300.5mm] 44.1" [1120mm] 11.8" [300.5mm] NEX T-GENER A TION N- T YPE Mounting Hole (x4) 0.5" [12mm] CELL TECHNOL OGY SILFAB SOLAR INC. 1770 Port Drive • Improved Shade Tolerance • Enhanced Durability 1.4" [35mm] Burlington WA 98233 USA • Improved Low-Light Performance • Reduced Degradation Rate 1.4" [35mm] 0.3" [7mm]0.6" T +1 360.569.4733 • Increased Performance in • 25-Year Product Warranty/ Back View [15mm] info@silfabsolar.com High Temperatures 30-Year Performance Warranty SILF AB SOLAR.C OM 0.06" 43" [1093mm] 7149 Logistics Lane Profile [1.5mm] 44.6" [1133mm] Fort Mill SC 29715 USA T +1 839.400.4338 53.15" 240 Courtneypark Drive East [1350mm] Mississauga ON L5T 2Y3 Canada Cable Length Grounding Hole T +1 905.255.2501 SILF AB SOLAR.C OM Drainage Hole (x8) Ø0.17" [Ø4.2mm] (x2) F +1 905.696.0267 Silfab - SIL-440-QD-20241217 DRAWING NUMBER: 2.4" [60mm] 8" [200mm] No reproduction of any kind is allowed without permission. Data and information is subject to modifications without notice. © Silfab Solar Inc., 2024. Silfab Solar® is a registered trademark of Silfab Solar Inc. SS BLUE RAVEN DATA SHEET IQ8MC Microinverter ]ILAR INPUT DATA (DC) UNITS IQ8MC-72-M-US Commonly used module pairings 1 W 260–460 To meet compatibility, PV modules must be within the following max. input DC voltage and max. module I . Module compatibility — Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator. sc MPPT voltage range V 25–45 Operating range V 18–58 Min./Max. start voltage V 22/58 Max. input DC voltage V 60 Max. continuous operating DC current A 14 Max. input DC short-circuit current A 25 Max. module I A 20 sc Overvoltage class DC port — II DC port backfeed current mA 0 PV array configuration — Ungrounded array; no additional DC side protection required; AC side protection requires max 20 A per branch circuit OUTPUT DATA (AC) UNITS IQ8MC-72-M-US @240 VAC IQ8MC-72-M-US @208 VAC Peak output power VA 330 315 IQ8MC Microinverter Easy to install Max. continuous output power VA 320 310 • Lightweight and compact with plug-and-play Nominal grid voltage (L-L) V 240, split-phase (L-L), 180° 208, single-phase (L-L), 120° Our newest IQ8 Series Microinverters are the industry’s first microgrid-forming*, software- connectors defined microinverters with split-phase power conversion capability to convert DC power to Min./Max. grid voltage 2 V 211–264 183–229 AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary • Power line communication (PLC) between Max. continuous output current A 1.33 1.49 application-specific integrated circuit (ASIC), which enables the microinverter to operate in components grid-tied or off-grid modes. This chip is built in advanced 55-nm technology with high-speed Nominal frequency Hz 60 • Faster installation with simple two-wire digital logic and has superfast response times to changing loads and grid events, alleviating cabling Extended frequency range Hz 47–68 constraints on battery sizing for home energy systems. AC short circuit fault current over three High productivity and reliability Arms 2.70 cycles • Produces power even when the grid is down* Max. units per 20 A (L-L) branch circuit 3 — 12 10 • More than one million cumulative hours of Total harmonic distortion testing % <5 • Class II double-insulated enclosure Overvoltage class AC port — III • Optimized for the latest high-powered PV Part of the Enphase Energy System, IQ8 Series Microinverters redefine AC port backfeed current mA 18 modules IQ8 Series Microinverters integrate with reliability standards with more than one Power factor setting — 1.0 the IQ Battery, IQ Gateway, and the million cumulative hours of power-on Enphase App monitoring and analysis testing, enabling an industry-leading Microgrid-forming Grid-tied power factor (adjustable) — 0.85 leading ... 0.85 lagging software. limited warranty of up to 25 years. • Complies with the latest advanced grid Peak efficiency % 97.4 97.2 support CEC weighted efficiency % 97.0 96.5 • Remote automatic updates for the latest grid Nighttime power consumption mW 33 25 requirements MECHANICAL DATA UNITS • Configurable to support a wide range of grid profiles Ambient temperature range -40°C to 65°C (-40°F to 149°F) • Meets CA Rule 21 (UL 1741-SA) and Relative humidity range 4% to 100% (condensing) Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed IEEE 1547:2018 (UL 1741-SB) to the IQ8 Series Microinverters that have as PV rapid shutdown equipment and DC connector type Stäubli MC4 integrated MC4 connectors. conforms with various regulations when Dimensions (H × W × D); Weight 212 mm (8.3") × 175 mm (6.9") × 30.2 mm (1.2"); 1.1 kg (2.43 lbs) installed according to the manufacturer’s NOTE: • IQ8 Microinverters cannot be mixed together with Cooling Natural convection – no fans instructions. previous generations of Enphase microinverters Approved for wet locations; Pollution degree Yes; PD3 (IQ7 Series, IQ6 Series, and so on) in the same system. Enclosure Class II double-insulated, corrosion-resistant polymeric enclosure • IQ Microinverters ship with default settings that meet North America’s IEEE 1547 interconnection Environ. category; UV exposure rating NEMA Type 6; outdoor standard requirements. Region-specific adjustments may be requested by an Authority COMPLIANCE Having Jurisdiction (AHJ) or utility representative. An IQ Gateway is required to make these changes CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01. *Meets UL 1741 only when installed with IQ System Controller 2 or 3. during installation. Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014, NEC 2017, NEC 2020, and NEC 2023 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer’s instructions. © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at (1) No enforced DC/AC ratio. https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. (2) Nominal voltage range can be extended beyond nominal if required by the utility. Data subject to change. IQ8MC-MC4-DSH-00049-4.0-EN-US-2024-02-09 (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8MC-MC4-DSH-00049-4.0-EN-US-2024-02-09 DRAWING NUMBER: SS Data Sheet Enphase Q Cable Accessories BLUE RAVEN Enphase Q Cable Accessories ]ILAR REGION: Americas CONDUCTOR SPECIFICATIONS Certification UL3003 (raw cable), UL 9703 (cable assemblies), DG cable Flame test rating FT4 Compliance RoHS, OIL RES I, CE, UV Resistant, combined UL for Canada and United States Conductor type THHN/THWN-2 dry/wet The Enphase Q Cableâ„¢ and accessories are part of Enphase Disconnecting means The AC and DC bulkhead connectors have been evaluated and approved by UL for use as the load-break the latest generation Enphase IQ Systemâ„¢. These disconnect required by NEC 690. Q Cable Accessories accessories provide simplicity, reliability, and faster Q CABLE TYPES / ORDERING OPTIONS installation times. Connectorized Models Size / Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Q-12-10-240 12 AWG / 277 VAC 1.3 m (4.2 ft) Portrait 240 Q-12-17-240 12 AWG / 277 VAC 2.0 m (6.5 ft) Landscape (60-cell) 240 Q-12-20-200 12 AWG / 277 VAC 2.3 m (7.5 ft) Landscape (72-cell) 200 ENPHASE Q CABLE ACCESSORIES Name Model Number Description Raw Q Cable Q-12-RAW-300 300 meters of 12 AWG cable with no connectors Enphase Q Cable Field-wireable connector (male) Q-CONN-10M Make connections from any open connector Field-wireable connector (female) Q-CONN-10F Make connections from any Q Cable open connector • Two-wire, double-insulated Enphase Q Cable is 50% lighter than the previous generation Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Enphase cable Disconnect tool Q-DISC-10 Disconnect tool for Q Cable connectors, DC connectors, and AC module mount • New cable numbering and plug and play connectors speed up installation and simplify Q Cable sealing caps (female) Q-SEAL-10 One needed to cover each unused connector on the cabling wire management Terminator Q-TERM-10 Terminator cap for unused cable ends • Link connectors eliminate cable waste Connect PV module using MC4 connectors to IQ micros with EN4 (TE PV4-S Enphase EN4 to MC4 adaptor¹ ECA-EN4-S22 SOLARLOK). 150mm/5.9” to MC4. For field wiring of UL certified DC connectors. EN4 (TE PV4-S SOLARLOK) to Enphase EN4 non-terminated adaptor¹ ECA-EN4-FW non-terminated cable. 150mm/5.9” Longer adapter cable for EN4 (TE PV4-S SOLARLOK) to MC4. Use with split Field-Wireable Connectors Enphase EN4 to MC4 adaptor (long)¹ ECA-EN4-S22-L cell modules or PV modules with short DC cable. 600mm/23.6” • Easily connect Q cables on the roof without Replacement DC Adaptor (MC4) Q-DCC-2 DC adaptor to MC4 (max voltage 100 VDC) complex wiring Replacement DC Adaptor (UTX) Q-DCC-5 DC adaptor to UTX (max voltage 100 VDC) • Make connections from any open connector and center feed any section of cable within 1. Qualified per UL subject 9703. branch limits • Available in male and female connector types TERMINATOR SEALING CAPS Terminator cap for unused cable Sealing caps for unused aggregator ends, sold in packs of ten and cable connections (Q-TERM-10) (Q-BA-CAP-10 and Q-SEAL-10) DISCONNECT TOOL CABLE CLIP Plan to use at least one per Used to fasten cabling to the racking installation, sold in packs of ten or to secure looped cabling, sold in (Q-DISC-10) packs of one hundred (Q-CLIP-100) To learn more about Enphase offerings, visit enphase.com © 2020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. To learn more about Enphase offerings, visit enphase.com 2020-06-26 DRAWING NUMBER: SS DATA SHEET IQ Combiner 5/5C BLUE RAVEN ]ILAR MODEL NUMBER IQ Combiner 5 with IQ Gateway printed circuit board for integrated revenue-grade PV production IQ Combiner 5 (X-IQ-AM1-240-5) metering (ANSIC12.20 ±0.5%), consumption monitoring (± 2.5%), and IQ Battery monitoring (±2.5%). Includes a silver solar shield to deflect heat. IQ Combiner 5C with IQ Gateway printed circuit board for integrated revenue-grade PV production metering (ANSI C12.20 ±0.5%), consumption monitoring (±2.5%) and IQ Battery monitoring (±2.5%). IQ Combiner 5C (X-IQ-AM1-240-5C) Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05)¹. Includes a silver solar shield to deflect heat. WHAT’S IN THE BOX IQ Gateway is the platform for total energy management for comprehensive, remote maintenance, and IQ Gateway printed circuit board management of the Enphase Energy System 80 A busbar with support for 1 × IQ Gateway breaker and  4 × 20 A breaker for installing IQ Series Busbar Microinverters and IQ Battery 5P IQ Gateway breaker Circuit breaker, 2-pole, 10 A/15 A Production CT Pre-wired revenue-grade solid-core CT, accurate up to ±0.5% X-IQ-AM1-240-5 Consumption CT Two consumption metering clamp CTs, shipped with the box, accurate up to ±2.5% X-IQ-AM1-240-5C IQ Battery CT One battery metering clamp CT, shipped with the box, accurate up to ±2.5% CTRL board Control board for wired communication with IQ System Controller 3/3G and the IQ Battery 5P IQ Combiner 5/5C Enphase Mobile Connect (only with IQ Combiner 5C) 4G-based LTE-M1 cellular modem (CELLMODEM-M1-06-SP-05) with a 5-year T-Mobile data plan Accessories kit Spare control headers for the COMMS-KIT-02 board Smart The IQ Combiner 5/5C consolidates interconnection equipment into a single enclosure and ACCESSORIES AND REPL ACEMENT PARTS (NOT INCLUDED, ORDER SEPARATELY) streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent, • Includes IQ Gateway for pre-wired solution for residential applications. IQ Combiner 5/5C uses wired control communication and control CELLMODEM-M1-06-SP-05 4G-based LTE-M1 cellular modem with a 5-year T-Mobile data plan communication and is compatible with IQ System Controller 3/3G and IQ Battery 5P. • Includes Enphase Mobile Connect CELLMODEM-M1-06-AT-05 4G-based LTE-M1 cellular modem with a 5-year AT&T data plan (CELLMODEM-M1-06-SP-05), only The IQ Combiner 5/5C, IQ Series Microinverters, IQ System Controller 3/3G, and IQ Battery with IQ Combiner 5C Supports Eaton BR2XX, Siemens Q2XX and GE/ABB THQL21XX Series circuit breakers (XX represents 5P provide a complete grid-agnostic Enphase Energy System. Circuit breakers (off-the-shelf) 10, 15, 20, 30, 40, 50, or 60). Also supports Eaton BR220B, BR230B, and BR240B circuit breakers • Supports flexible networking: Wi-Fi, compatible with the hold-down kit. Ethernet, or cellular BRK-10A-2-240V, BRK-15A-2-240V, BRK-20A-2P-240V, BRK-15A-2P-240V-B, and BRK-20A-2P- • Provides production metering Circuit breakers (provided by Enphase) 240V-B (more details in the “Accessories” section) (revenue grade) and consumption monitoring XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 5/5C XA-ENV2-PCBA-5 IQ Gateway replacement printed circuit board (PCB) for IQ Combiner 5/5C Easy to install X-IQ-NA-HD-125A Hold-down kit compatible with Eaton BR-B Series circuit breakers (with screws) IQ Series Microinverters IQ System Controller 3/3G • Mounts to one stud with centered The high-powered smart grid-ready IQ Series Provides microgrid interconnection brackets XA-COMMS2-PCBA-5 Replacement COMMS-KIT-02 printed circuit board (PCB) for IQ Combiner 5/5C Microinverters (IQ6, IQ7, and IQ8 Series) simplify device (MID) functionality by • Supports bottom, back, and side ELECTRICAL SPECIFICATIONS the installation process. automatically detecting grid failures and conduit entries seamlessly transitioning the home energy Rating 80 A system from grid power to backup power. • Supports up to four 2-pole branch circuits for 240 VAC plug-in breakers System voltage and frequency 120/240 VAC, 60 Hz (not included) Busbar rating 125 A • 80 A total PV branch circuits Fault current rating 10 kAIC • Bluetooth-based Wi-Fi provisioning for easy Wi-Fi setup Maximum continuous current rating (input from PV/storage) 64 A Up to four 2-pole Eaton BR, Siemens Q, or GE/ABB THQL Series distributed generation (DG) breakers Branch circuits (solar and/or storage) Reliable only (not included) • Durable NRTL-certified NEMA type 3R Maximum total branch circuit breaker rating (input) 80 A of distributed generation/95 A with IQ Gateway breaker included IQ Battery 5P IQ Load Controller enclosure Fully integrated AC battery system. Includes six Helps prioritize essential appliances IQ Gateway breaker 10 A or 15 A rating GE/Siemens/Eaton included field-replaceable IQ8D-BAT Microinverters. during a grid outage to optimize energy • 5-year limited warranty consumption and prolong battery life. Production metering CT 200 A solid core pre-installed and wired to IQ Gateway • 2-year labor reimbursement program coverage included for both the Consumption monitoring CT (CT-200-CLAMP) A pair of 200 A clamp-style current transformers is included with the box IQ Combiner SKUs* IQ Battery metering CT 200 A clamp-style current transformer for IQ Battery metering, included with the box • UL1741 Listed 1. A plug-and-play industrial-grade cell modem for systems of up to 60 microinverters. Available in the United States, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate 5-year limited cellular service in the installation area. warranty *For country-specific warranty information, see the https://enphase.com/installers/resources/warranty page. © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. DRAWING NUMBER: Data subject to change. IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 SS MECHANICAL DATA Accessories BLUE RAVEN 37.5 cm × 49.5 cm × 16.8 cm (14.75" × 19.5" × 6.63"). Height is 21.06" (53.5 cm) with mounting Dimensions (W × H × D) ]ILAR brackets Weight 7.5 kg (16.5 lbs) Mobile Connect Circuit breakers Ambient temperature range -40°C to 46°C (-40°F to 115°F) 4G-based LTE-M1 cellular modem with a 5-year BRK-10A-2-240V Circuit breaker, 2-pole, 10 A, Eaton BR210 data plan BRK-15A-2-240V Circuit breaker, 2-pole, 15 A, Eaton BR215 Cooling Natural convection, plus heat shield (CELLMODEM-M1-06-SP-05 for Sprint and BRK-20A-2P-240V Circuit breaker, 2-pole, 20 A, Eaton BR220 CELLMODEM-M1-06-AT-05 for AT&T) BRK-15A-2P-240V-B Circuit breaker, 2-pole, 15 A, Eaton BR215B Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction with hold-down kit support BRK-20A-2P-240V-B Circuit breaker, 2-pole, 20 A, Eaton • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors BR220B with hold-down kit support • 60 A breaker branch input: 4 to 1/0 AWG copper conductors Wire sizes • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors • Always follow local code requirements for conductor sizing Built-in CTRL board for wired communication with IQ Battery 5P and IQ System Controller 3/3G. Communication (in-premise connectivity) Integrated power line communication for IQ Series Microinverters CT-200-SOLID CT-200-CLAMP Altitude Up to 2,600 meters (8,530 feet) 200 A revenue-grade solid core Production CT 200 A clamp-style consumption and battery COMMUNICATION INTERFACES with <0.5% error rate (replacement SKU) metering CT with <2.5% error rate (replacement SKU) Integrated Wi-Fi 802.11b/g/n (dual band 2.4 GHz/5 GHz), for connecting the Enphase Cloud through the internet Wi-Fi range (recommended) 10 m (32.8 feet) Bluetooth BLE4.2, 10 m range to configure Wi-Fi SSID Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included), for connecting to the Enphase Ethernet Cloud through the internet Cellular/Mobile Connect CELLMODEM-M1-06-SP-05 or CELLMODEM-M1-06-AT-05 (included with IQ Combiner 5C) Digital I/O Digital input/output for grid operator control USB 2.0 Mobile Connect, COMMS-KIT-01 for IQ Battery 3/3T/10/10T, COMMS-KIT-02 for IQ Battery 5P Access point (AP) mode For connection between the IQ Gateway and a mobile device running the Enphase Installer App Metering ports Up to two Consumption CTs, one IQ Battery CT, and one Production CT Power line communication 90–110 kHz Web API See https://developer-v4.enphase.com Local API See guide for local API COMPLIANCE UL 1741, CAN/CSA C22.2 No. 107.1, Title 47 CFR, Part 15, Class B, ICES 003, NOM-208-SCFI-2016, IQ Combiner with IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1, IEEE 1547: 2018 (UL 1741-SB, 3rd Ed.), IEEE 2030.5/CSIP Compliant, Production metering: ANSI C12.20 accuracy class 0.5 (PV production) COMPATIBILITY PV Microinverters IQ6, IQ7, and IQ8 Series Microinverters IQ System Controller EP200G101-M240US00 COMMS-KIT-01 2 IQ System Controller 2 EP200G101-M240US01 IQ Battery ENCHARGE-3-1P-NA, ENCHARGE-10-1P-NA, ENCHARGE-3T-1P-NA, ENCHARGE-10T-1P-NA IQ System Controller 3 SC200D111C240US01, SC200G111C240US01 COMMS-KIT-02 3 IQ Battery IQBATTERY-5P-1P-NA 2. For information about IQ Combiner 5/5C compatibility with the 2nd-generation batteries, refer to the compatibility matrix. DRAWING NUMBER: 3. IQ Combiner 5/5C comes pre-equipped with COMMS-KIT-02. IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 SS DATA SHEET IQ Gateway BLUE RAVEN ]ILAR MODEL NUMBER ENV-IQ-AM1-240, ENV2-IQ-AM1-240 IQ Gateway IQ Gateway integrates revenue grade PV production metering (ANSI C12.20 ±0.5%), consumption ENV-IQ-AM1-240 metering (±2.5%), and battery metering (±2.5%) with IQ Battery 5P. ENV2-IQ-AM1-240 (IEEE® 1547:2018) Includes one 200 A continuous rated Production Current Transformer (CT). ACCESSORIES - ORDER SEPARATELY Mobile Connect - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan COMMS-CELLMODEM-M1-06 - 4G based LTE-M1 cellular modem with 5-year Sprint data plan CELLMODEM-M1-06-SP-05 - 4G based LTE-M1 cellular modem with 5-year AT&T data plan CELLMODEM-M1-06-AT-05 Consumption monitoring CT and IQ Battery 5P metering CT CT-200-SPLIT Split-core and clamp style CTs with 2.5% accuracy enable whole home and IQ Battery 5P metering CT-200-CLAMP Communications Kit Installed at the IQ Gateway. For communications with IQ Battery and IQ System Controller. Includes COMMS-KIT-01 USB cable for connection to IQ Gateway or IQ Combiner and allows wireless communication with IQ COMMS-KIT-02 Battery and IQ System Controller. POWER REQUIREMENTS AC power requirements 120/240 V, 120/208Y V, or 127/220Y V. Three-wire. 60 Hz. IQ Gateway breaker 2-pole and maximum 20 A overcurrent protection required IQ Gateway Typical power consumption 5 W CAPACITY Smart Number of microinverters polled Up to 300 The IQ Gateway delivers solar production and energy consumption data to Enphase • Enables web-based monitoring Installer Portal monitoring and analysis software for comprehensive, remote maintenance, and control MECHANICAL AND ELECTRICAL DATA and management of Enphase systems. • Provides bidirectional Dimensions (W × H × D) 21.3 cm × 12.6 cm × 4.5 cm (8.4 in × 5 in × 1.8 in) communications for remote Weight 1.09 lb With integrated production metering and optional consumption monitoring, the IQ Gateway is upgrades the platform for total energy management. It integrates with the IQ System Controller and IQ -40°C to 65°C (-40°F to 149°F) [ENV-IQ-AM1-240] • Supports power export limiting and Ambient temperature range -40°C to 50°C (-40°F to 122°F) [ENV2-IQ-AM1-240] Battery. zero-export applications -40°C to 46°C (-40°F to 115°F) if installed in an enclosure IP30. For installation indoors or in an NRTL-certified, NEMA type 3R or better-rated enclosure, if installing Simple Environmental rating outdoors. • Easy system configuration using Altitude Up to 2,600 meters (8,530 feet) Enphase Installer App COMMUNICATION INTERFACES • Flexible networking with Wi-Fi, Ethernet, or cellular Integrated Wi-Fi 802.11b/g/n (2.4 GHz, 5 GHz), for connecting the Enphase Cloud via the internet. IQ Series Microinverters IQ System Controller Wi-Fi range (recommended) 10 m The high-powered smart grid-ready IQ Series Provides microgrid interconnect device Reliable Microinverters (IQ6, IQ7, and IQ8 Series) (MID) functionality by automatically Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included), for connecting to the Enphase • Designed for installation indoors Ethernet dramatically simplify the installation process. detecting grid failures and seamlessly Cloud via the internet. or outdoors in a NEMA 3R rated transitioning the home energy system enclosure CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (to be purchased separately, mandatory for from grid power to backup power. Mobile Connect sites with IQ Battery) • 5-year limited warranty • ENV2-IQ-AM1-240 complies with Digital I/O Digital input/output for grid operator control IEEE® 1547:2018 (UL 1741-SB, 3rd Ed.) USB 2.0 For Mobile Connect and Communications Kit Access point (AP) mode For a connection between the IQ Gateway and a mobile device running the Enphase Installer App Metering ports Up to two Consumption CTs, one Production CT, and one battery CT (for IQ Battery 5P) Power line communication (PLC) 90 kHz–110 kHz (Class B), to microinverters. Web API Refer to https://developer-v4.enphase.com IQ Battery IQ Load Controller All-in-one AC coupled storage system that is Helps prioritize essential appliances Local API Refer to guide for local API reliable, smart, simple, and safe. It provides during a grid outage to optimize From top to bottom: Cloud connectivity, Wi-Fi access point mode, PV production state, PLC backup capability and installers can quickly energy consumption and prolong LED indicators communications state design the right system size to meet the needs battery life. of both new and retrofit solar customers. Configured via Enphase Installer App and Enphase Installer Platform © 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at DRAWING NUMBER: https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the US and other countries. IQ-G-DSH-00111-3.0-EN-US-2023-12-20 IQ-G-DSH-00111-3.0-EN-US-2023-12-20 Data subject to change. SS POWER PRODUCTION/EXPORT LIMITING VIA THE IQ GATEWAY’S DIGITAL IO Revision history Maximum relays read 4 BLUE RAVEN ]ILAR Power production limiting (Production CT/s required), power export limiting (Production CT/s required Capabilities supported and Consumption CT/s – Load with Solar configuration) REVISION DATE DESCRIPTION Minimum IQ Gateway version v7.3.120 Cable configurations 18 AWG, UL-Std. 62, 600 V, 105°C, and minimum 0.03 inches average thickness DSH-00111-3.0 December 2023 Updated power requirement and added IG Gateway breaker values. Signal voltage range 2.5 V–5 V (digital high), 0 V–1.9 V (digital low) DSH-00111-2.0 August 2023 Updated temperature specification for ENV2-IQ-AM1-240. Terminal blocks Five terminals, up to 0.002 in2 DSH-00111-1.0 June 2023 Updated altitude and recommended maximum microinverters on a site. Configuration via Enphase Installer App, Enphase Installer Platform (site settings) SCOPE OF DELIVERY Package dimensions (H × W × D) 6.3 in × 10.8 in × 3.9 in Package weight 2.2 lb Aluminium DIN rail 4.9 in Current transformers (CTs) One CT-200-SOLID included COMPLIANCE CA Rule 21 (UL 1741-SA), IEEE® 1547:2018 - UL 1741-SB, 3rd Ed.(ENV2-IQ-AM1-240), UL 61010-1 CAN/CSA C22.2 No. 61010-1 Compliance Title 47 CFR, Part 15, Class B, ICES 003 IEC/EN 61010-1:2010, EN50065-1, EN61000-4-5, EN61000-6-1, EN61000-6-2 Metering: ANSI C12.20 accuracy class 0.5 (PV production only) COMPATABILITY IQ System Controller SC200D111C240US01, SC200G111C240US01, EP200G101-M240US01, EP200G101-M240US00 IQ Battery IQBATTERY-5P-1P-NA, ENCHARGE-3T-1P-NA, ENCHARGE-10T-1P-NA Microinverter IQ6, IQ7, and IQ8 Series Microinverters 1.8 8.4 8.4 1.8 5 5 All Dimensions in inches All dimensions in inchesAll dimensions in inches All dimensions in inches Accessories Enphase Mobile Connect Circuit breakers 4G-based LTE-M1 cellular modem with a 5-year BRK-10A-2-240V Circuit breaker, 2-pole, 10 A, Eaton BR210 data plan BRK-15A-2-240V Circuit breaker, 2-pole, 15 A, Eaton BR215 (CELLMODEM-M1-06-SP-05 for Sprint and BRK-20A-2P-240V Circuit breaker, 2-pole, 20 A, Eaton BR220 CELLMODEM-M1-06-AT-05 for AT&T) BRK-15A-2P-240V-B Circuit breaker, 2-pole, 15 A, Eaton BR215B with hold-down kit support BRK-20A-2P-240V-B Circuit breaker, 2-pole, 20 A, Eaton BR220B with hold-down kit support CT-200-SOLID CT-200-CLAMP 200 A revenue grade solid core Production CT 200 A clamp-style consumption and battery with <0.5% error rate (replacement SKU) metering CT with <2.5% error rate (replacement SKU) © 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at IQ-G-DSH-00111-3.0-EN-US-2023-12-20 https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the US and other countries. DRAWING NUMBER: Data subject to change. IQ-G-DSH-00111-3.0-EN-US-2023-12-20 SS BLUE RAVEN ]ILAR WIRING DIAGRAMS ~7.25 .28 DIA NOT FUSIBLE [7) ~ (3 HOLES) r-=-o / :n AH ' .,./ B }H '~:· l 1 9.63 [24-5] ~ b3 TERMif'W.. LUGS * rl f.-- N.tPERES MAX. WIRE MIN. WIRE lYPE A,B,C KNOCKOUTS 60 #2AWG #10 AWG AL ::!)}: ........-- #2AWG #14 AWG cu :.~: ~~:.... ·- (~ ......___A,B,c - KNOCKOUTS KNOCKOUTS _4.5~,- L3.7~- [114] SYMBOL A c D [95] • CONDUIT SIZE .50 .75 1 1.25 17.75 NEMA TYPE 3R [197] J A.B.~~ fOl KNOCKOUTS 16 ~ 6 . INCHES DUAL DIMENSIONS. MILUMETERS ~:",8,C,D KNOCKOUTS HORSEPOWER RATINGS CATALOC WIRING , .... 240VAC NUMBER VOLTAGE RAllNGS MAX. 10 JO DU222RB 24fNAC A 10 - NOTES: DU322RB 24fNAC • 10 15 FINISH - GRAY BAKED ENAMEL UL LISTED - FILE E-2B75 SUITABLE FOR USE AS SERVICE EQUIPMENT TOP OF NEMA TYPE 3R SWITCHES HA.VE PRO'Y1SIONS FOR MAXIMUM 2 1/2N BOLT-ON HUB. GENERAL DUTY SAFETY SWITCHES a• IAFE D SHORT CIRCUIT CURRENT RATINGS: VlSIBLE BLADE TYPE 10,000 AMPERES WHEN USED WITH OR PR01ECTED BY CLASS H OR K FUSES 60 AMPERE ~ Schneider Electric 100,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS R FUSES. ENCLOSURE - NEMA TYPE JR RAINPROOF :j: LUGS SUITABLE FOR 60'C OR 75"C COPPER OR ALUUINU~ CONDUCTORS. :w.' 1861 DECEMBER 2004 REF DWG #1861 DRAWING NUMBER: SS JB-1.2, JB-1.XL Phone: 385-202-4150 Specification Sheet  www.ezsolarproducts.com BLUE RAVEN ]ILAR  PV Junction Box for Composition/Asphalt Shingle Roofs A. System Specifications and Ratings ITEM No. PART NUMBER DESCRIPTION QTY Size DWG. NO. Rev POLYCARBONATE B JB-1.2 • Maximum Voltage: 1,000 Volts 1 JB-1.2 Body 1 WITH UV INHIBITORS • Maximum Current: JB-1.2: 80 Amps; JB-1.XL: 120 Amps SCALE: 1:2 WEIGHT: 1.45 LBS SHEET 1 of 3 POLYCARBONATE • Allowable Wire: 14 AWG – 6 AWG 2 JB-1.2 Lid 1 WITH UV INHIBITORS Torque Specification: 15-20 LBS • Spacing: Please maintain a spacing of at least ½” between uninsulated live parts and fittings for conduit, armored cable, and uninsulated live parts of opposite polarity. #10 x 1-1/4” Phillips UL 1741, nema 3r 3 6 certification: CSA C22.2 No. 290 • Enclosure Rating: Type 3R pan head screw • Roof Slope Range: 2.5 – 12:12 #8 x 3/4” Phillips WEIGHT: 1.45 LBS 4 6 • Max Side Wall Fitting Size: 1” pan head screw • Max Floor Pass-Through Fitting Size: 1” • Ambient Operating Conditions: (-35°C) - (+75°C) • Compliance: - JB-1.2: UL1741, CSA C22.2 No. 290; JB-1.XL: UL1741, CSA C22.2 No. 290 - Approved wire connectors: must conform to UL1741, CSA C22.2 No. 290 • System Marking: Interek Symbol and File #5019942  • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion between components, components that are found to be affected are to be replaced immediately. Table 1: Typical Wire Size, Torque Loads and Ratings Torque 1 Conductor 2 Conductor Type NM Inch Lbs Voltage Current ABB ZS6 terminal block 10-24 awg 16-24 awg Sol/Str 0.5-0.7 6.2-8.85 600V 30 amp ABB ZS10 terminal block 6-24 awg 12-20 awg Sol/Str 1.0-1.6 8.85-14.16 600V 40 amp ABB ZS16 terminal block 4-24 awg 10-20 awg Sol/Str 1.6-2.4 14.6-21.24 600V 60 amp ABB M6/8 terminal block 8-22 awg Sol/Str .08-1 8.85 600V 50 amp Ideal 452 Red WING-NUT 8-18 awg Sol/Str Self-Torque Self-Torque 600V Wire Connector Ideal 451 Yellow WING-NUT 10-18 awg Sol/Str Self-Torque Self-Torque 600V Wire Connector Ideal, In-Sure Push-In Connector 10-14 awg Sol/Str Self-Torque Self-Torque 600V Part #39 WAGO, 2204-1201 10-20 awg 16-24 awg Sol/Str Self-Torque Self-Torque 600V 30 amp WAGO, 221-612 10-20 awg 10-24 awg Sol/Str Self-Torque Self-Torque 600V 30 amp Dottie DRC75 6-12 awg Sol/Str Snap-In Snap-In Patents: ezsolarproducts.com/patents 4-6 awg Sol/Str 45 ESP NG-53 2000V 10-14 awg Sol/Str 35 4-6 awg Sol/Str 45 ESP NG-717 2000V 10-14 awg Sol/Str 35 4-6 awg Sol/Str 45 Brumall 4-5,3 2000V 10-14 awg Sol/Str 35 Table 2: Minimum wire-bending space for conductors through a wall opposite terminals in mm (inches) Wires per terminal (pole) Wire size, AWG or 1 2 3 4 or More kcmil (mm2) mm (inch) mm (inch) mm (inch) mm (inch) 14-10 (2.1-5.3) Not Specified - - - 8 (8.4) 38.1 (1-1/2) - - - 6 (13.3) 50.8 (2) - - - PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EZ SOLAR. DRAWING NUMBER: ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED.  Phone: 385-202-4150 | www.ezsolarproducts.com SS ISSUE DATE: ISSUE DATE: RIGID PVC CONDUIT FITTINGS DATE D'EMISSION: 2009 04 30 RIGID PVC CONDUIT FITTINGS DATE D'EMISSION: 2009 04 30 BLUE RAVEN ]ILAR SUPERCEDES: SUPERCEDES: JB444 JUNCTION BOXES REMPLACE: 2004 07 15 JB444 JUNCTION BOXES REMPLACE: 2004 07 15 5 5 COVER DIMENSIONS 4.010” (102mm) B A C ® E ® 4.010” (102mm) C B D PRODUCT PART NOMINAL SIZE A B C CODE NUMBER (in) (mm) (in) (mm) (in) (mm) (in) (mm) 0.245” 076668 J444 STAHLIN 4 103 3.675 93 4.000 102 3.450 88 076259 AMJB444 ALLIED 4 103 3.675 93 4.000 102 3.450 88 (6 mm) 077643* 2037-424T CANLET 4 103 3.675 93 4.000 102 3.450 88 077696 JB 444 4 103 4.000 101 4.395 112 3.950 101 PRODUCT PART NOMINAL SIZE D E VOLUME 0.190” DIA CODE NUMBER (in) (mm) (in) (mm) (in) (mm) (cu. In) (cu. Cm) 076668 J444 STAHLIN 4 103 4.180 106. 3.850 98 51.5 844.6 076259 AMJB444 ALLIED 4 103 4.180 106 3.850 98 51.5 844.6 077643* 2037-424T CANLET 4 103 4.180 106 3.850 98 51.5 844.6 0.700” 077696 JB 444 4 103 4.170 106 3.930 100 51.5 844.6 0.250” PRODUCT PART NOMINAL SIZE GASKET INSERT SCREW M.FEET Small Mounting Feet CODE NUMBER (in) (mm) CODE CODE CODE CODE 076668 J444 STAHLIN 4 103 072538 (4) 1.970” Product Code 097747 076259 AMJB444 ALLIED 4 103 072538 (4) 077643* 2037-424T CANLET 4 103 072538 (4) 0.175” 077696 JB 444 4 103 097731 072538 (4) 072522 (4) 097747 072539 (2) 072513 (2) * BOX WITH MOLDED MOUNTING FEET, INSERT ONLY; NO COVER, OR GASKET, UL LISTED 576J DRAWING NUMBER: Page: CONDUIT – 41.1 Page: CONDUIT – 41.2 SS BLUE RAVEN ]ILAR “Stay Connected” with Solar Power Components ® Heyco®-Tite Liquid Tight Cordgrips for Enphase Q Cables Straight-Thru, NPT Hubs with Integral Sealing Ring ALL NEW The Ultimate in Liquid Tight Strain Relief Protection PRODUCT! GLAND PART NO. DESCRIPTION PART DIMENSIONS •Two new cordgrips now accommodate CONFIGURATION AB C D E the Enphase Q Cable – M3231GCZ Conductors or Clearance Max. O.A. Thread Wrenching Nut (1/2˝ NPT) and M3234GDA-SM Type Size No. Black Hole Dia. Length Length Thickness Flat Size (3/4˝ NPT). * mm. in. mm. in. mm. in. mm. in. mm. in. mm. •The 1/2˝ version provides liquid tight Oval Gland entry for one Enphase Q Cable – Q Cable 6,1 x 9,7 1 M3231GCZ LTCG 1/2 6.1x9.7MM .875 22,2 1.70 43,2 .61 15,5 .21 5,3 .98 24,9 .24 x .38˝ (6,1 x 9,7 mm). Break-Thru Skinned Over Gland •The 3/4˝ version provides liquid tight Q Cables 6,1 x 9,7 2 SMCG 3/4 2-6.1x9.7MM entry for up to two Enphase Q Cables – plus M3234GDA-SM 1.040 26,4 2.00 50,8 .62 15,7 .25 6,4 1.30 33,0 3,3 1 1-3.3MM Ground .24 x .38” (6,1 x 9,7 mm) and an Metal Locknuts INCLUDED. B additional .130” (3,3 mm) dia. hole for C a #8 solid grounding cable. D A •The 3/4˝ version utilizes our skinned- over technology so any unused holes will retain a liquid tight seal. E •Rated for use with DG Cable. SUGGESTED CLEARANCE HOLE SEALING NUT INTEGRAL FOR NONTHREADED MOUNTING SEALING RING Material Nylon 6/6 with TPE Sealing Gland Certifications Listed under Underwriters’ Laboratories File E504900 CSA Certified by the Canadian Standards Association File 93876 Flammability Rating 94V-2 Temperature Range Static -40°F (-40°C) to 239°F (115°C) Dynamic -4°F (-20°C) to 212°F (100°C) IP Rating IP 68 ALL NEW Heyco® Helios® UVX Clip – Blind Mount PRODUCT! PANEL THICKNESS RANGE WIRE DIAMETER PART NO. DESCRIPTION MOUNTING OVERALL •The jersey pine tree mounting style RANGE HOLE DIA. HEIGHT installs easily with superior holding Minimum Maximum 1-2 Wires AC power. in. mm. in. mm. in. mm. in. mm. •UVX nylon protects from corrosion due 1-2 Wires to outdoor exposure. .028 0,7 .250 6,4 .23 (5,8 mm) - .32 (8,0 mm) S6520 Helios UVX Clip 100 Pack .260 6,6 .96 24,4 •Installs into .260˝ (6,6 mm) mounting each cable S6560 Helios UVX Clip Bulk hole. •Holds up to 2 cables between .230 - .315˝ (5,8 - 8,0 mm) each. •Cables install with fingertip pressure. •Molded from our robust UVX nylon 6/6 with extended UV capabilities for our Solar 20 Year Warranty. Material Nylon 6/6 with extended UV Capabilities Flammability Rating 94V-2 Temperature Range Dynamic -4°F (-20°C) to 185°F (85°C) DRAWING NUMBER: 1-800-526-4182 • 732-286-1800 (NJ) • FAX: 732-244-8843 • www.heyco.com 1-4b SS BLUE RAVEN ]ILAR SFM INFINITY 6 7 5 4 1 2 3 SYSTEM OVERVIEW 20% FEWER ATTACHMENTS PART NAME DESCRIPTION Save time and money on every project: SFM INFINITY requires fewer attachments than rail systems. 1 TRIMRAIL Structural front trim provides aesthetic and aligns modules. 2 INSTALLS PER DAY Make two installs per day your new standard. SFM INFINITY has fewer 2 TRIMRAIL SPLICE Connects and electrically bonds sections of TRIMRAIL. roof attachments, one tool installation, and pre-assembled components to get you off the roof 40% faster. 3 TRIMRAIL FLASHKIT Attaches TRIMRAIL to roof. Available for comp shingle or tile. OF HOMEOWNERS % 4 SFM INFINITY 15 Attachments 87 PREFER MODULE CLIPS Secure modules to TRIMRAIL. 5 MICRORAIL Connects modules to SLIDERS. Provides post-install array leveling. BETTER AESTHETICS 6 Install the system with the aesthetics preferred by homeowners, Connects and supports modules. Provides east-west bonding. SPLICE ATTACHED SPLICE also available. with integrated front trim, trim end caps, dark components, and recessed hardware. 7 SLIDER FLASHKIT Roof attachment and flashing. Available for comp shingle and tile. RAIL 20 Attachments MAXIMUM POWER DENSITY 30% LOGISTICS SAVINGS Easily mix module orientations to achieve optimal power density With fewer SKUs and compact components, SFM INFINITY is easier to without incurring the increased bill of materials, labor, and BONDING AND ACCESSORIES stock, easier to transport, and easier to lift to the roof. Plus, make more attachments required by rail. efficient use of your vehicle fleet. PART NAME DESCRIPTION TRIMRAIL ENDCAPS Covers ends of TRIMRAIL for refined aesthetic. 2MW 3MW TRIMRAIL BONDING CLAMP Electrically bonds TRIMRAIL and modules N/S BONDING CLAMP Electrically bonds rows of modules SFM INFINITY REVOLUTIONIZES ROOFTOP SOLAR WITH BENEFITS ACROSS YOUR BUSINESS, FROM DESIGN AND LOGISTICS, THROUGH ARRAY INSTALLATION AND SERVICE. DRAWING NUMBER: SS SUN BLUE RAVEN SFM FRAME SYSTEM BONDING & GROUNDING 22 ]ILAR MICRORAILâ„¢ INSTALLATION GUIDE PAGE E-W BONDING PATH: E-W module to module bonding is accomplished with 2 pre-installed bonding pins which engage on the secure side of the MicrorailTM and splice. Star Washer is WEEBLUG Single Use Only Single Use Only Alternate method N-S BONDING PATH: TERMINAL TORQUE, N-S module to module bonding is Install Conductor and accomplished with bonding clamp with 2 integral torque to the following: TERMINAL TORQUE, TERMINAL TORQUE, bonding pins. (refer also to alternate method) 4-6 AWG: 35in-lbs Install Conductor and Install Conductor and 8 AWG: 25 in-lbs torque to the following: torque to the following: 10-14 AWG: 20 in-lbs 4-14 AWG: 35in-lbs 6-14 AWG: 7ft-lbs LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO Ilsco Lay-In Lug (GBL-4DBT) Ilsco Flange Lug (SGB-4) Wiley WEEBLug (6.7)  • 10-32 mounting hardware • 1/4” mounting hardware • 1/4” mounting hardware • Torque = 5 ft-lb • Torque = 75 in-lb • Torque = 10 ft-lb Alternate method • AWG 4-14 - Solid or Stranded • AWG 4-14 - Solid or Stranded • AWG 6-14 - Solid or Stranded TRIMRAIL BONDING PATH: NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION Trimrail to module bonding is accomplished with System bonding is accomplished through modules. System grounding accomplished by attaching bonding clamp with integral bonding pin and bonding T-bolt. (refer also to alternate method) DRAWING NUMBER: a ground lug to any module at a location on the module specified by the module manufacturer. SS SUN BLUE RAVEN SFM FRAME COMPATIBLE MODULES 28 ]ILAR MICRORAILâ„¢ SYSTEM CERTIFICATION PAGE Electrical Bonding and Grounding Test Modules The list below is not exhaustive of compliant modules but shows those that have been evaluated and found to be electrically compatible with the SFM system. Manufacture Module Model / Series Manufacture Module Model / Series Manufacture Module Model / Series Aleo P-Series ET Solar ET-M672BHxxxTW FF-MP-BBB-370 LGxxxN2T-A4 DNA-120-(BF/MF)26, DNA-144-(BF/MF)26 Freedom Forever FF-MP1-BBB-xxx, FF-MP-BBB-xxx, LGxxx(A1C/E1C/E1K/N1C/N1K/N2T/N2W/ Aptos DNA-120-(BF/MF)10-440W, Q1C/Q1K/S1C/S2W)-A5 DNA-108-(BF/MF)10-400W FreeVolt Mono PERC LGxxxN2T-B5 GCL GCL-P6 & GCL-M6 Series LGxxxN1K-B6 CHSM6612P, CHSM6612P/HV, CHSM6612M, TD-AN3, TD-AN4, LGxxx(A1C/M1C/M1K/N1C/N1K/Q1C/Q1K/ Astronergy CHSM6612M/HV, CHSM6610M (BL)(BF)/(HF), Hansol UB-AN1, UD-AN1 LG Electronics QAC/QAK)-A6 CHSM72M-HC LGxxx(N1C/N1K/N2T/N2W)-E6 36M, 60M, 60P, 72M & 72P Series, AXN6M610T, AXN6P610T, LGxxx(N1C/N1K/N2W/S1C/S2W)-G4 Auxin Heliene 144HC M6 Monofacial/ Bifacial Series, AXN6M612T & AXN6P612T LGxxxN2T-J5 144HC M10 SL Bifacial LGxxx(N1K/N1W/N2T/N2W)-L5 AXIblackpremium 60 (35mm), HT60-156(M) (NDV) (-F), LGxxx(N1C/Q1C/Q1K)-N5 AXIpower 60 (35mm), HT Solar HT 72-156(M/P) LGxxx (N1C/N1K/N2W/Q1C/Q1K)-V5 Axitec AXIpower 72 (40mm), AXIpremium 60 (35mm), KG, MG, TG, RI, RG, TI, MI, HI & KI Series Hyundai AXIpremium 72 (40mm). HiA-SxxxHG LR4-60(HIB/HIH/HPB/HPH)-xxxM LR4-72(HIH/HPH)-xxxM BVM6610, ITEK iT, iT-HE & iT-SE Series Boviet LR6-60(BP/HBD/HIBD)-xxxM (30mm) BVM6612 Japan Solar JPS-60 & JPS-72 Series LR6-60(BK)(PE)(HPB)(HPH)-xxxM (35mm) BYD P6K & MHK-36 Series LONGi LR6-60(BK)(PE)(PB)(PH)-xxxM (40mm) JAP6 60-xxx, JAM6-60-xxx/SI, JAM6(K)-60/ CS1(H/K/U/Y)-MS LR6-72(BP)(HBD)(HIBD)-xxxM (30mm) xxx, JAP6(k)-72-xxx/4BB, JAP72SYY-xxx/ZZ, CS3(K/L/U), CS3K-MB-AG, CS3K-(MS/P) LR6-72(HV)(BK)(PE)(PH)(PB)(HPH)-xxxM JAP6(k)-60-xxx/4BB, JAP60SYY-xxx/ZZ, CS3N-MS, CS3U-MB-AG, CS3U-(MS/P), CS3W (35mm) Canadian Solar JAM6(k)-72-xxx/ZZ, JAM72SYY-xxx/ZZ, CS5A-M, CS6(K/U), CS6K-(M/P), CS6K-MS JA Solar LR6-72(BK)(HV)(PE)(PB)(PH)-xxxM (40mm) JAM6(k)-60-xxx/ZZ, JAM60SYY-xxx/ZZ. CS6P-(M/P), CS6U-(M/P), CS6V-M, CS6X-P Meyer Burger Black i. YY: 01, 02, 03, 09, 10 Meyer Burger ii. ZZ: SC, PR, BP, HiT, IB, MW, MR Meyer Burger White Centrosolar America C-Series & E-Series JAM54S31 xxx/MR Mission Solar Energy MSE Series CT2xxMxx-01, CT2xxPxx-01, CertainTeed CTxxxMxx-02, CTxxxM-03, JKM & JKMS Series Mitsubishi MJE & MLE Series CTxxxMxx-04, CTxxxHC11-04 Jinko Eagle JKMxxxM JKMxxxM-72HL-V Neo Solar Power Co. D6M & D6P Series Dehui DH-60M Eco Solargy Orion 1000 & Apollo 1000 Kyocera KU Series • Unless otherwise noted, all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes "/" between one or more items indicates that either of those items may be the one that is present in a module's model ID • Please see the SFM UL2703 Construction Data Report at unirac.com to ensure the exact solar module selected is approved for use with SFM • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 15 for further information DRAWING NUMBER:SS SUN BLUE RAVEN SFM FRAME COMPATIBLE MODULES 29 ]ILAR MICRORAILâ„¢ SYSTEM CERTIFICATION PAGE Electrical Bonding and Grounding Test Modules The list below is not exhaustive of compliant modules but shows those that have been evaluated and found to be electrically compatible with the SFM system. Manufacture Module Model / Series Manufacture Module Model / Series Manufacture Module Model / Series A-Series A400-BLK , SPR-MAX3-XXX-R, EVPVxxx (H/K/PK), TwinPeak Series X-Series, E-Series & P-Series, VBHNxxxSA15 & SA16, TwinPeak 2 Series SunPower Axxx-BLK-G-AC, SPR-Mxxx-H-AC VBHNxxxSA17 & SA18, TwinPeak 2 BLK2 Series REC (cont.) SPR-Mxxx-BLK-H-AC Panasonic VBHNxxxSA17(E/G) & SA18E, TwinPeak 2S(M)72(XV) TwinPeak 3 Series (38mm) Suntech STP, STPXXXS - B60/Wnhb VBHNxxxKA01 & KA03 & KA04, VBHNxxxZA01, VBHNxxxZA02, TP4 (Black) TP572, TP596, TP654, TP660, Talesun VBHNxxxZA03, VBHNxxxZA04 TP672, Hipor M, Smart Renesola Vitrus2 Series & 156 Series SC, SC B, SC B1, SC B2 Peimar SGxxxM (FB/BF) Risen RSM72-6 (MDG) (M), RSM60-6 Tesla TxxxH, TxxxS Phono Solar PS-60, PS-72 SEG-xxx-BMD-HV SEG Solar PA05, PD05, DD05, DE06, DD06, PE06, Prism Solar P72 Series SEG-xxx-BMD-TB Trina PD14, PE14, DD14, DE09.05, DE14, DE15, Plus, Pro, Peak, G3, G4, G5, G6(+), G7, G8(+) S-Energy SN72 & SN60 Series (40mm) PE15H Pro, Peak L-G2, L-G4, L-G5, L-G6, L-G7 Seraphim SEG-6 & SRP-6 Series UNIxxx-120M-BB, UNIxxx-120MH, Universal Solar UNIxxx-108M-BB, Q.PEAK DUO BLK-G6+ Sharp NU-SA & NU-SC Series Q.PEAK DUO BLK-G6+/TS UP-MxxxP(-B), SLA, SLG, BC Series & SILxxx(BL/NL/NT/HL/ Upsolar Silfab UP-MxxxM(-B) Q.PEAK DUO (BLK)-G8(+) ML/BK/NX/NU/HC/QM) Q.PEAK DUO L-G8.3/BFF D7MxxxH7A, D7(M/K)xxxH8A Solarever USA SE-166*83-xxxM-120N United Renewable Energy Q.Cells FAKxxx(C8G/E8G), FAMxxxE7G-BB Q.PEAK DUO (BLK) ML-G9(+) (URE) PowerXT-xxxR-(AC/PD/BD) FAMxxxE8G(-BB), FBMxxxMFG-BB Q.PEAK DUO XL-G9/G9.2/G9.3 Solaria PowerXT-xxxC-PD URECO F6MxxxE7G-BB Q.PEAK DUO (BLK) ML-G10(+) PowerXT-xxxR-PM (AC) Eldora, Q.PEAK DUO XL-G(10/10.2/10.3/10.c/10.d) Sunmodule Protect, SolarWorld Vikram Solivo, Q.PEAK DUO BLK ML-G10+ / t Sunmodule Plus Somera Q.TRON BLK M-G2+ SERIES SS-M-360 to 390 Series, VSUNxxx-(108/120)M-BB Alpha (72) (Black) (Pure) SS-M-390 to 400 Series, VSUN VSUNxxx-108BMH RECxxxAA (PURE-R) (Pure-RX) Sonali SS-M-440 to 460 Series, RECxxxNP3 Black SS-M-430 to 460 BiFacial Series, Waaree AC & Adiya Series N-Peak (Black) SS 230 - 265 Winaico WST & WSP Series REC N-Peak 2 (Black) SunEdison F-Series, R-Series & FLEX FXS Series Yingli YGE & YLM Series PEAK Energy Series PEAK Energy BLK2 Series Suniva MV Series & Optimus Series ZN Shine ZXM6-72, ZXM6-NH144-166_2094 PEAK Energy 72 Series • Unless otherwise noted, all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes "/" between one or more items indicates that either of those items may be the one that is present in a module's model ID • Please see the SFM UL2703 Construction Data Report at unirac.com to ensure the exact solar module selected is approved for use with SFM DRAWING NUMBER: • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 15 for further information SS BLUE RAVEN ]ILAR DRAWING NUMBER: SS BLUE RAVEN ]ILAR DRAWING NUMBER: SS