HomeMy WebLinkAbout19223 68th Dr Ne_BLD2942_2025 Permit #: 2942 Permit Date: 12/19/19 Permit Type: FIRE SPRINKLER Project Name: R&L Carriers Applicant Name: Patriot Fire Protection, Inc Applicant Address: 2707 70th Ave E. Applicant, City, State, Zip: Tacoma Contact: Pietro Demonte Phone: 2539262290 Email: ap@patriotfire.com Scope of Work: Fire Sprinkler Valuation: 172000.00 Square Feet: 54540 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 01/10/2020 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Raelynn Jones Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 31051400302900 19223 68th Drive NE SEC 14 TWP 31 RGE 05 RLR TH PTN OF SW1/4 BEING INVESTMENTS A PTN OF LOTS 3,5,6,9,10 LLC & 11 OF SURV REC AF NO 7905290175 DAF COM AT SELY COR LOT 21 OF SD SURV TH S79*55 47E ALG N LN LOT 3 OF SD SURV 60FT TH S10*04 13W102.20FT TO TPB TH N46*01 15E 315.12FT TH N10*04 13E 97.97FT TH S79*55 47E 530.50FT TH S10*04 13W 572.10FT TH N88*50 41W 728.21FT TO BEG OF CRV TO R WHOSE RAD CTR BEARS N01*09 19E 30FT TH ALG ARC OFSD CRV TO R 66.92FT THRU A C/A OF 127*47 59 TO THE BEG OF REV CRV TO L WHOSE RAD CTR BEARS N51*02 42W 280FT TH ALG ARC OF SD REV CRV TO L 141.16FT THRU A C/A OF 28*53 05 TAP TH BEARS S10*04 13W FR TPB TH N10*04 13E 152.50FT TO TPB PER BLA REC AF NO 9009260178 Contractors Contractor Primary Contact Phone Address Contractor Type License License # PATRIOT FIRE CONSTRUCTION Labor and Derek Gust 2532843527 2707 70th Ave E. PATRIFP099CF PROTECTION CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status FS07. FIRE 05/21/2020 FIRE Approved SPRINKLER FINAL Plan Reviews Date Review Type Description Assigned To Review Status 12/19/2019 FIRE SPRINKLER BUILDING 1. Permit and set of approved plans to remain on site during installation. 2. Significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections: may include hangers, earthquake bracing, sprinkler locations and pipe re-routing that could impact hydraulic calculations. Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted. 3. Cover inspection required. 4. Hydrostatic test for wet and dry systems required: 200 psi for 2 hours minimum. 5. Pneumatic air test for dry systems required: 40 psi for 12/19/2019 FIRE SPRINKLER FIRE 24 hours minimum. 6. Weatherproof horn strobes shall be installed in lieu of electric bells on exterior of buildings. Horn strobes shall be installed above sprinkler riser room doors for each building. 7. Any mechanical tee cut-outs shall be tied to sprinkler piping and be visible at time of cover inspection. 8. Sprinkler system Contractor’s Material and Test Certificate shall be submitted prior to close out of permit. 9. Owner shall be provided with a set of approved plans and associated documents for their files. 10. Call at least 48 hours in advance to schedule inspections. A DCVA is required at Point of Connection. 12/19/2019 FIRE SPRINKLER PW-WAT-REV Gus Fees Fee Description Notes Amount Fire Sprinkler System Commercial NFPA 13/13R $2,062.46 Fire System Plan Review Table 4-1 $100.00 Processing/Technology $25.00 Credit Card Service $65.62 Total $2,253.08 Attached Letters Date Letter Description 12/19/2019 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 01/09/2020 Shaina Morgan 78543625 $2,187.46 01/09/2020 78543625 CC Surcharge Raelynn Jones $65.62 Outstanding Balance $0.00 Uploaded Files Date File Name 10/11/2021 9866269-2942_IC 6.15.2020.pdf 10/11/2021 9866270-2942_IC 7.7.2020.pdf 10/11/2021 9866271-2942_IC 5.27.2020.pdf 05/21/2020 6698258-2942_Contractors Material and Test Certificate for Underground piping.pdf 01/10/2020 6079522-2942_Issued Permit.pdf 12/19/2019 6013740-2942_Application.pdf