HomeMy WebLinkAbout3633 177th Pl Ne_BLD6586_2025
06/30/2025
RESIDENTIAL MECHANICAL APPLICATION
Community andEconomic Development
City of Arlington • 18204 59th Ave NE •Arlington, WA 98223• Phone (360) 403-3551
This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping.
Please fill out all pages of this application and include all information.
Type of Permit: New Installation Addition/Alteration/Repair Gas Piping
3630 177th Place Northeast
Property Address: Arlington, WA 98223 Project Valuation: $20,000
Lot #: Parcel ID No.: 00598900002500 Preferred Contact: Owner Contractor
Project Description: NEW AIR HANDLER AND HEAT PUMP REPLACEMENTS
Owner Name: CHERRIE JOHNSTON Home No.: (360) 722-9252
Email Address: chersok@yahoo.com Cell No.:
SAME AS ABOVE City: State: Zip:
Contractor Name: CM HEATING, LLC Office No.: 4252590550
Email Address: PERMITS@CMHEATING.COM Cell No.:
1500 INDUSTRY ST #200 City: EVERETT State: WA Zip: 98203
L&I Contractor License Number: CMHEAHL751LW Expiration Date: 06/17/2027
New gas piping requires a pressure test hooking to any appliance
Sediment traps (drips) are required on all gas lines
Gas lines are required to be supported/secured every 6 to 8 feet
Proper Combustion air and venting required for all appliances
A shut-off valve is required within 6 feet of all appliances
Gas Piping Information Not Applicable
CSST rass Other
Galvanized Steel _______________________________________
Proposed Piping Size: ½†¾†1†1½†2â€
MECHANICAL PERMIT FEES (per unit)
Type of Fixture No. of Units Cost per Unit Subtotal Model No.
Additional Plan Review fees x $ 75.00 =
x $ 15.00 =
x $ 25.00 =
x $ 50.00 =
Air Handling Units x $ 15.00 =
1 x $ 25.00 = $ 25.00
x $ 15.00 =
x $ 25.00 =
REV03.2022 Page 1of 2
MECHANICAL PERMIT FEES (per unit)
x $ 50.00 =
-15hp x $ 15.00 =
-30hp x $ 25.00 =
Commercial Hoods -Type I x $ 25.00 =
Commercial Hoods -Type II x $50.00 =
Diffusers x $ 15.00 =
Dryer Ducting x $ 15.00 =
Ductwork (drawings required) x $ 25.00 =
Evaporative Coolers x $ 15.00 =
x $ 15.00 =
x $ 15.00 =
1 x $ 15.00 =
x $ 25.00 =
Gas Clothes Dryer x $ 15.00 =
x $ 15.00 =
x $ 25.00 =
x $ 50.00 =
x $ 15.00 =
x $ 2.00 =
Heat Exchangers x $ 15.00 =
Heat Pump-Condensing Unit 1 x $ 25.00 =
Hot Water Heat Coils x $ 15.00 =
- regulated by $ 15.00
x =
mechanical code, not otherwise specified
x $ 25.00 =
Pkg. Units >100btu x $50.00 =
Range/Cook top- x $ 15.00 =
x $ 15.00 =
x $ 25.00 =
x $ 50.00 =
Re-inspection fee x $ 75.00 =
Residential Range Hood x $ 15.00 =
x $ 15.00 =
x $ 25.00 =
VAV $ 10.00
x =
conditioning system)
Wall Heaters - x $ 25.00 =
Water Heater - x $ 25.00 =
$75.00
$25.00
Total
REV2.2020 Page 2 of 2
PRESSURE PIPING SCHEMATIC
GAS PIPING ONLY
SCHEMATIC IS TO SCALE SCHEMATIC NOT TO SCALE
Show Pipe Size(s) and Length(s) from meter to all appliances
NOTE:Any interior pressure regulators must be indicated
ILYSE MELLO 06/25/2025
Signature Print Name Date
REV2.2020 Page 3of 3
Permit #: 6586
Permit Date: 06/27/25
Permit Type: RESIDENTIAL MECHANICAL
Project Name: Johnston
Applicant Name: CM Heating LLC
Applicant Address: 1500 Industry St #200
Applicant, City, State, Zip: Everett, WA 98203
Contact: Ilyse Mello
Phone: 4252590550
Email: permits@cmheating.com
Scope of Work: NEW FURNACE AND HEAT PUMP REPLACEMENTS
Valuation: 20000.00
Square Feet: 1538
Number of Stories: 1
Construction Type: VB
Occupancy Group: R-3; Residential
ID Code:
Permit Issued: 06/30/2025
Permit Expires: 12/29/2025
Form Permit Type: RESIDENTIAL MECHANICAL
Status: COMPLETE
Assigned To: Hannah Hardwick
Property
Parcel # Address Legal Description Owner Name Owner Phone Zoning
JOHNSTON
100 SINGLE
CHERRIE
00598900002400 3633 177TH PL NE FAMILY
M/SCHMIDT
RESIDENCE
GEOFFREY A
Contractors
Contractor Primary Contact Phone Address Contractor Type License License #
1500 INDUSTRY CONSTRUCTION Plumbing
CM HEATING INC 425-259-0550 CMHEAHL750LP
ST STE 200 CONTRACTOR Contractor
1500 INDUSTRY CONSTRUCTION Construction
CM HEATING INC 425-259-0550 CMHEAHL751W
ST STE 200 CONTRACTOR Contractor
1500 INDUSTRY CONSTRUCTION
CM HEATING INC 425-259-0550 UBI 605890285
ST STE 200 CONTRACTOR
Inspections
Date Inspection Type Description Scheduled Date Completed Date Inspector Status
R00. FURNACE
10/31/2025 11/03/2025 11/03/2025 BUILDING Approved
FINAL
Fees
Fee Description Notes Amount
Processing/Technology $25.00
Inspection $75.00
Forced Air Heat ≤ 100 BTU/h Enter # of units $15.00
Heat Pump - Condensing Unit Enter # of units $25.00
Mechanical Base Permit Fee $25.00
Credit Card Service $4.95
Total $169.95
Attached Letters
Date Letter Description
06/27/2025 Building Permit
06/27/2025 Web Form- Residential Mechanical Application
Payments
Date Paid By Description Payment Type Accepted By Amount
06/27/2025 Matt Zivanov 235477723 Hannah Hardwick $4.95
XBP Conf:
06/27/2025 $165.00
235477723
Outstanding Balance $0.00
Notes
Date Note Created By:
10/24/2025 Expiration notice sent LaNay Hendrick
06/27/2025 emailed contractor asking for spec sheets Hannah Hardwick
Uploaded Files
Date File Name
06/30/2025 27107628-2025_BLD6586_Issued Permit.pdf
06/27/2025 27097487-JOHNSTON - SPEC SHEET.pdf
06/27/2025 f7ceb5fb09d917eec3490bd4609eb9b5_johnston_-_site_plan.pdf
06/27/2025 cf2e97f0569e0334409e315771c45154_johnston-_mech_permit.pdf
R454b
Refrigerant SUBMITTAL DATA SHEET
Series Name: Extreme Heat AHUSeries
Model Number: MAUHE-H36B-2A/MO1SE-H36B-2A
Air Handler Heat Pump System
Location: Approval:
Engineer: Date:
Submitted to: Construction:
Submitted by: Unit #:
Reference: Drawing #:
INDOOR SPECIFICATION
ESP(in.W.G) 0-0.8
Indoor Air Flow (Turbo/H/M/L/Si) (CFM) 1189 / 1083 / 971 / 865 / 865
Indoor Noise Level (Turbo/H/M/L/Si) (dBA) 49 / 48 /45.5 / 25.5 /25.5
Dimension inch 21 x 21 x 49
(W×D×H) mm 534 × 534 × 1245
Package inch 26-9/16 x 24-7/16 x 52-9/16
(W×D×H) mm 675 × 620 × 1335
lbs 129 / 154
Net/Gross Weight
kg 58.7 / 69.8
OUTDOOR SPECIFICATION
Compressor Type TWIN-ROTARY
Compressor Model EKPQ420D1UMUA
Refrigerant R454B
Refrigerant Oil Charge(mL) 1,460
Refrigerant Oil VG75
Outdoor Air Flow (Max) (CFM) 3,002
Outdoor Noise Level (dBA) 62.5
Dimension inch 38-9/16 x 16-3/8 x 38-3/8
(W×D×H) mm 980 × 415 × 975
Package inch 45-1/16 x 19-11/16 x 42-1/2
(W×D×H) mm 1145 × 500 × 1080
lbs 204 /235
Net/Gross Weight
kg 92.6 / 106.7
EFFICIENCY ELECTRICAL
Cooling Heating Indoor Power Supply 115/208/230V,60Hz,1Ph
SEER2 17.4 HSPF2-4 10.2 Indoor MCA 115V/(208/230V) 8.0/6.0
EER2 11.7 COP 3.60 Indoor MOP 15.0
Outdoor Power Supply 208/230V,60Hz,1Ph
PERFORMANCE of Cooling Outdoor MCA 29.0
Cooling (Btu/hr) Outdoor MOP 30.0
Rated Capacity 36,000 Communication Wiring AWG 20/2
Min/Max Capacity 9,700 ~ 42,000 Compressor RLA 20.5
Moisture Removal(L/h) 3.4 Outdoor Fan Motor RLA 2.4
Standard Operating Range(℉/℃) -22~122(-30~50) Outdoor Fan Motor W 250
Rated Cooling Conditions: Indoor: 80℉ DB/67℉ WB Indoor Fan Motor RLA 4.5
Outdoor: 95℉ DB/75℉ WB Indoor Fan Motor W 375
System Power Input @ Cooling (W) 3,076(820 ~ 4,440)
PERFORMANCE of Heating System Power Input @ Heating (W) 3,012(665 ~ 4,370)
Heating (Btu/hr) MCA: Min. circuit amps (A) MOCP: Max. over current protection (A)
1. @ 47℉ Rated 37,000 RLA: Rated load amps (A) W: Fan motor rated output (W)
2. @ 47℉ Min/Max Capacity 1,1000 ~ 48,000
3. @ 17℉ Rated 31,800 PIPING
4. @ 5℉ Rated: Capacity / COP 39,000/1.9 Throttle type(Indoor) EXV
5. @ 5℉ Max: Capacity 39,000 Throttle type(Outdoor) EXV
Standard Operating Range(℉/℃) -22~75 (-30~24) Liquid Size 3/8'' (9.52mm)
1. Rated Heating Conditions: Indoor: 70℉ DB/60℉ WB Gas Size 3/4'' (19mm)
Outdoor: 47℉ DB/43℉ WB Max. Piping Length(ft/m) 246 (75)
2. Rated Heating Conditions: Indoor: 70℉ DB/60℉ WB Max. Height Difference(ft/m) 98 (30)
Outdoor: 17℉ DB/15℉ WB Max. Pre-charged Length(ft/m) 25 (7.5)
3. Heating Conditions, Compressor Indoor: 70℉ DB/60℉ WB Refrigerant Pre-charged Amount(oz/kg) 127 (3.6)
Operating at Max. Frequency Outdoor: 5℉ DB/5℉ WB Additional Charge of Refrigerant((oz/ft)/(g/m)) 0.7 (65)
Connection Method Flared
Indoor Unit Dimension
Unit:inch(mm)
Body Code W(inch/mm)
H(inch/mm)
D(inch/mm)
Outdoor Unit Dimension
Unit:inch(mm)
Installation Instruction For Outdoor Unit
Fan Performance For Indoor Unit
Features
â— Multi-position installation: horizontal(left or right), vertical( up or down)
â— Aluminum Coil
â— Constantly Air Flow system up to 0.80 In.W.G
â— 1 inch R4.2 fiberglass free insulation reduces condensation and boosts efficiency(optional)
â— Optional Auxiliary heat kit up to 25kW
â— Easy Maintenance
â— Multiple control options available:
â—‹ Two way communication wired controller:120N(X6)
â—‹ Two way communication wired controller with built-in WiFi:120N(X6W)
â—‹ Wireless remote controller
â—‹ Third-Party 24V Thermostat
â— Adaptive Control System
â— High efficiency up to 19 SEER2, 12.5 EER2, 10.3 HSPF2
â— 100% heat output at -4F*
â— Chassis heater and crankcase heater equipped as standard
* For 36K model, rated cooling capacity/heating capacity at -4F=100%