HomeMy WebLinkAbout4820 Longhouse Trail Lane Ne Ste 106_BLD6561_2025 Docusign Envelope ID: FA089952-4BF7-45C6-87BB-2D9B860B21E0
CITY OF ARLINGTON
18204 59th Avenue NE, Arlington, WA 98223
INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551
BUILDING PERMIT
4820 LONGHOUSE TRAIL LANE NE STE 106 Permit #: 6561
PERMIT EXPIRES 180 DAYS AFTER
Parcel #: 31052800102400
DATE OF ISSUANCE.
Scope of Work: Hair Salon Valuation: 178000.00
OWNER APPLICANT CONTRACTOR
ARLINGTON 51ST ST LLC BYK Construction, Inc. BYK Construction
PO BOX 619 PO Box 619 PO Box 619
SEDRO WOOLLEY, WA 98284 Sedro Woolley, WA 98284 Sedro Woolley, WA 98284
425-610-5059 360-661-5325
LIC: 603187914 EXP: 03/31/2026
LIC: BYKCOCI886JB EXP: 04/02/2026
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
LIC #: EXP: LIC #: EXP:
JOB DESCRIPTION
PERMIT TYPE: COMMERCIAL ALTERATION CODE YEAR: 2021
STORIES: 1 CONST. TYPE: VA
DWELLING UNITS: OCC GROUP: B; Business
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any
other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the
Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any
period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice
or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is
authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or
any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or
decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or
on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or
federal law, or any order, proclamation, guidance or decision of the Governor.
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK
AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE
STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND
ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN
MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110.
SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on
your sales tax return form and coded City of Arlington #3101.
07/01/2025
Applicant Signature Date Building Official Date
Docusign Envelope ID: FA089952-4BF7-45C6-87BB-2D9B860B21E0
CONDITIONS
Must provide Backflow protection before any branch lines from main line water. Adhere to approved plans. Permit shall be onsite
for inspections. Call for inspections.
The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property
owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or
community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities
before commencing construction. The property owner shall ensure that the construction project complies with all applicable design
review requirements.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE
PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS,
MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
07/01/2025 Building Plan Review $1,399.92
07/01/2025 Processing/Technology $25.00
07/01/2025 Building Permit $2,153.72
07/01/2025 State Surcharge - Commercial $25.00
Total Due: $3,603.64
Total Payment: $3,603.64
Balance Due: $0.00
CALL FOR INSPECTIONS
Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections
When calling for an inspection please leave the following information:
Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon
INSPECTION INFORMATION Pass/Fail
Certificate Of Completion
Envelope Id: FA089952-4BF7-45C6-87BB-2D9B860B21E0 Status: Completed
Subject: Complete with Docusign: Building+Permit29910460.pdf
Source Envelope:
Document Pages: 2 Signatures: 1 Envelope Originator:
Certificate Pages: 2 Initials: 0 Anna Holleman
AutoNav: Enabled PO BOX 619
EnvelopeId Stamping: Enabled Sedro Woolley, WA 98284-1447
Time Zone: (UTC-08:00) Pacific Time (US & Canada) annah@bykconstruction.com
IP Address: 50.46.13.128
Record Tracking
Status: Original Holder: Anna Holleman Location: DocuSign
7/1/2025 4:25:20 PM annah@bykconstruction.com
Signer Events Signature Timestamp
Anna Holleman Sent: 7/1/2025 4:27:19 PM
annah@bykconstruction.com Viewed: 7/1/2025 4:27:27 PM
Project Engineer Signed: 7/1/2025 4:27:33 PM
BYK Construction, Inc.
Signature Adoption: Pre-selected Style
Security Level: Email, Account Authentication
(None) Using IP Address: 50.46.13.128
Electronic Record and Signature Disclosure:
Not Offered via Docusign
In Person Signer Events Signature Timestamp
Editor Delivery Events Status Timestamp
Agent Delivery Events Status Timestamp
Intermediary Delivery Events Status Timestamp
Certified Delivery Events Status Timestamp
Carbon Copy Events Status Timestamp
City Of Arlington Permitting Sent: 7/1/2025 4:27:20 PM
wo@iworq.net
Security Level: Email, Account Authentication
(None)
Electronic Record and Signature Disclosure:
Not Offered via Docusign
Hannah Hardwick Sent: 7/1/2025 4:27:19 PM
HHardwick@arlingtonwa.gov Viewed: 7/1/2025 4:27:42 PM
Security Level: Email, Account Authentication
(None)
Electronic Record and Signature Disclosure:
Not Offered via Docusign
Witness Events Signature Timestamp
Notary Events Signature Timestamp
Envelope Summary Events Status Timestamps
Envelope Sent Hashed/Encrypted 7/1/2025 4:27:20 PM
Envelope Summary Events Status Timestamps
Certified Delivered Security Checked 7/1/2025 4:27:27 PM
Signing Complete Security Checked 7/1/2025 4:27:33 PM
Completed Security Checked 7/1/2025 4:27:33 PM
Payment Events Status Timestamps
COMMERCIAL TENANT IMPROVEMENT
PERMIT APPLICATION
Community and Economic Development
City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551
The following information is required for Commercial, Multi-Family, and Mixed-Use Building Permit Applications.
Mark each box to designate that the information has been provided. Please submit this checklist as part of the
submittal documents. See ASSISTANCE BULLETIN #30 for detailed design requirements.
EACH BUILDING OR STRUCTURE REQUIRES A SEPARATE SUBMITTAL.
SUBMIT ELECTRONIC FILES FOR EACH OF THE FOLLOWING; Incomplete applications will not be accepted.
REQUIRED DOCUMENTS
City of Arlington Commercial Tenant Improvement Permit Application
Site Plan
Architectural Plans
Structural Plans
Structural Calculations
Mechanical System Modifications, (if applicable)
Plumbing System Modifications, (if applicable)
Project Specification Manuals, (if applicable)
WSEC Compliance Forms, (if applicable) https://waenergycodes.com/
Special Inspection and Testing Agreement
Deferred Submittal Request
Airport Property Lease (if building is located within the Arlington Airport Property Boundary)
1. Plan Review fee is due at time of submittal and remaining balance will be due at time of issuance.
2. The City of Arlington does not review or inspect electrical systems. Contact Labor and Industries at lni.wa.gov or
360-416-3000.
A. DEFERRED SUBMITTALS
If the project requires any of the following, a Deferred Submittal Request MUST be completed. Deferred submittals require
separate applications, plans and plan review.
1. Mechanical Plans (if not included in the plan set)
2. Plumbing Plans (if not included in the plan set)
3. Fire Sprinkler
4. Fire Alarm
5. Signage
B. SPECIAL INSPECTION AND TESTING AGREEMENT
A Special Inspection Firm is required to perform special inspections for the following type of work.
*The Special Inspection and Testing Agreement MUST be submitted with the Building Application.
Reinforced Concrete Structural Steel and Welding
Bolting in Concrete High-Strength Bolting
Pre-stressed Concrete Spray-Applied Fireproofing
Shotcrete Smoke-Control Systems
Structural Masonry Other - Specify: ______________________________________
I acknowledge that all items designated as submittal requirements must accompany my Tenant
Improvement Permit Application to be considered a complete submittal.
COMMERCIAL TENANT IMPROVEMENT
INSTALLATION, MODIFICATION OR REMOVAL MAY REQUIRE A SEPARATE PERMIT SUBMITAL
*CHECK ALL THAT APPLY
Automatic fire extinguishing systems Compressed gas systems
Fire pumps Flammable and combustible liquids (tanks, piping etc.)
Standpipe systems Hazardous materials
Private fire hydrants Industrial ovens/furnace
Fire alarm and detection systems Spraying or dipping operations
High piled/rack storage Temporary membrane structure, tents (>200 sq. ft.) or canopies (>400 sq. ft.)
Provide details on any of the above checked items: _________________________________________________________________________
________________________________________________________________________________________
Type of Permit: New Space Addition Alteration
Property Address: Project Valuation:
Lot #: Parcel ID No.: Subdivision:
Project Scope of Work:
Description of New Tenant Business Operations:
IBC Construction Type: IBC Occupancy Type:
Building/Space Square Footage: Number of Stories:
Square Footage Per Floor: 1st 2nd 3rd 4th 5th 6th
Primary Contact: Owner Architect Engineer Contractor
Owner Name: Office No.:
Email Address: Cell No.:
Mailing Address: City: State: Zip:
Architect Name: Office No.:
Email Address: Cell No.:
Mailing Address: City: State: Zip:
Professional License Number: Expiration Date:
Engineer Name: Office No.:
Email Address: Cell No.:
Mailing Address: City: State: Zip:
Professional License Number: Expiration Date:
Primary Contractor: Office No.:
Email Address: Cell No.:
Mailing Address: City: State: Zip:
L&I Contractor License Number: Expiration Date:
REV03.2022 Page 2 of 7
COMMERCIAL TENANT IMPROVEMENT
MECHANICAL SYSTEM INFORMATION
Type of Permit: ï² New Installation ï² Addition ï² Alteration ï² Replaced ï² Gas Piping
Mechanical Contractor: Office No.:
Email Address: Cell No.:
Mailing Address: City: State: Zip:
L&I Contractor License Number: Expiration Date:
• New gas piping requires a pressure test hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured per IFGS, Section 415
• Proper Combustion air and venting required for all appliances
• A shut-off valve is required within 6 feet of each appliance
Gas Piping Specification and complete Schematic PAGE 4 ï² Not Applicable
Proposed Piping Material: ï² CSST ï² Brass ï² Black Steel ï² Galvanized Steel ï² Other
Proposed Piping Size: ï² Â½â€ ï² â…â€ ï² Â¾â€ ï² 1â€ ï² 1Â½â€ ï² 2â€
Inlet Pressure: Pressure Drop: Specific Gravity:
MECHANICAL PERMIT FEES (per unit)
Type of Fixture No. of Units Cost per Unit Subtotal
Additional Plan Review fees x $ 75.00 = $
Air Cond. Unit ≤100Btu/h x $ 15.00 = $
Air Cond. Unit >100Btu/h x $ 25.00 = $
Air Cond. Unit >500Btu/hp x $ 50.00 = $
Air Handling Units x $ 15.00 = $
Base Mechanical Fee $ 25.00 $ 25.00
Boiler <100Btu/h >3hp x $ 15.00 = $
Boiler >1 million Btu/h<50hp x $ 25.00 = $
Boiler >1.5 million Btu/h<50hp x $ 50.00 = $
Boiler >100Btu/h 3-15hp x $ 15.00 = $
Boiler >500Btu/h 15-30hp x $ 25.00 = $
Commercial Hoods -Type I x $ 25.00 = $
Commercial Hoods -Type II x $ 50.00 = $
Diffusers x $ 15.00 = $
Dryer Ducting x $ 15.00 = $
Ductwork (drawings required) x $ 25.00 = $
Evaporative Coolers x $ 15.00 = $
Exhaust/Ventilation Fans x $ 15.00 = $
Fireplace/Insert/Stove x $ 15.00 = $
Forced Air Heat ≤100 Btu/h x $ 15.00 = $
Forced Air Heat >100 Btu/h x $ 25.00 = $
Gas Clothes Dryer x $ 15.00 = $
Gas Fired AC ≤100 Btu/h x $ 15.00 = $
REV03.2022 Page 3 of 7
COMMERCIAL TENANT IMPROVEMENT
MECHANICAL PERMIT FEES (per unit)
Gas Fired AC >100 Btu/h x $ 25.00 = $
Gas Fired AC > 500 Btu/h x $ 50.00 = $
Gas Piping ≤ 5 units x $ 15.00 = $
Gas Piping > 5 units (plus <5 units) x $ 2.00 = $
Heat Exchangers x $ 15.00 = $
Heat Pump-Condensing Unit x $ 25.00 = $
Hot Water Heat Coils x $ 15.00 = $
Miscellaneous Appliance - regulated by $ 15.00 $
x =
mechanical code, not otherwise specified
Pkg. Units ≤100btu x $ 25.00 = $
Pkg. Units >100btu x $ 50.00 = $
Range/Cook top-Gas Fired x $ 15.00 = $
Refrigeration Unit ≤100Btu/h x $ 15.00 = $
Refrigeration Unit >100Btu/h x $ 25.00 = $
Refrigeration Unit >500Btu/h x $ 50.00 = $
Re-inspection fee (all) x $ 75.00 = $
Unit Heaters ≤ 100 Btu/h x $ 15.00 = $
Unit Heaters >100 Btu/h x $ 25.00 = $
VAV Boxes (Variable Air Volume, part of air $ 10.00 $
x =
conditioning system)
Wall Heaters - Gas Fired x $ 25.00 = $
Water Heater - Gas Fired x $ 25.00 = $
Permit Fee $
Table 4-8; Plan Review Fee $
Processing/Technology Fee $25.00
Total $
PRESSURE PIPING SCHEMATIC
COMPLETE FOR GAS PIPING ONLY – USE A SEPARATE SHEET, IF NECESSARY
ï² SCHEMATIC IS TO SCALE ï² SCHEMATIC NOT TO SCALE
Show Pipe Size(s) and Length(s) from meter to all appliances
NOTE: Any interior pressure regulators must be indicated
REV03.2022 Page 4 of 7
COMMERCIAL TENANT IMPROVEMENT
PLUMBING SYSTEM INFORMATION
Type of Permit: ï² New Installation ï² Addition ï² Alteration ï² Replaced ï² Industrial
Plumbing Contractor: Office No.:
Email Address: Cell No.:
Mailing Address: City: State: Zip:
L&I Contractor License Number: Expiration Date:
The following items need to be specified on the plans:
ï² Fixture specifications and equipment with locations.
ï² Location and type of all backflow assemblies for each fixture.
ï² Calculations for Grease Interceptor.
ï² Pipe size and location of sanitary and potable water systems.
ï² Riser diagram of waste, vent, and rain water systems, including sizes.
ï² Medical gas piping riser diagram, type of gas, storage room and size of piping.
PLUMBING PERMIT FEES (per fixture)
Commercial plumbing permits are required to submit line drawings. A plan review fee of 65% per Table 4-6 for
plumbing permits will be assessed at time of submittal. Includes two (2) inspections with permit.
Type of Fixture No. of Fixtures Cost per Fixture Subtotal
Additional Plan Review fees x $ 75.00 =
Alteration/repair piping x $ 15.00 =
Backflow Assembly x $25.00 =
Base Plumbing Fee $ 25.00 $25.00
Bath/Shower Combo x $ 15.00 =
Building Main Waste x $ 25.00 =
Clothes Washer x $ 15.00 =
Dishwasher x $ 15.00 =
Drinking Fountain x $ 15.00 =
Floor Drains x $ 15.00 =
REV03.2022 Page 5 of 7
COMMERCIAL TENANT IMPROVEMENT
PLUMBING PERMIT FEES (per fixture)
Grease Interceptor x $ 75.00 =
Grease Trap x $ 25.00 =
Hose Bibb x $ 15.00 =
Icemaker/Refrigerator x $ 15.00 =
Irrigation – per meter x $ 25.00 =
Kitchen Sink & Disposal x $ 15.00 =
Laundry Tray x $ 15.00 =
Lavatory x $ 15.00 =
Med Gas Piping ≤ 5 inlets/outlets x $ 60.00 =
Med Gas Piping > 5 inlets/outlets (plus ≤ 5 x $ 5.00 =
inlets/outlets)
Miscellaneous – regulated by plumbing x $ 15.00 =
code, not otherwise specified
Pretreatment Interceptor x $ 15.00 =
Re-inspection Fee (all) x $ 75.00 =
Roof Drains x $ 15.00 =
Shower (only) x $ 15.00 =
Sink (bar, service, etc.) x $ 15.00 =
Toilets x $ 15.00 =
Urinal x $ 15.00 =
Vacuum Breakers x $ 25.00 =
Water Heater x $ 25.00 =
Water Heater - Tankless x $ 25.00 =
Permit Fee
Table 4-6; Plan Review Fee
Processing/Technology Fee $25.00
Total
PROPOSED BUILDING USE
ï² New ï² Addition/Alteration ï² Medical ï² Automotive Based ï² Industrial
ï² Office ï² Restaurant ï² Machine Shop ï² Other: ____________________________________
CROSS CONNECTION
Please check all appliances that are proposed or permanently connected to the water supply.
ï² Ice Machine ï² Dialysis Equip. ï² Air washers
ï² Coffee Urn/Espresso ï² Hydrotherapy Equip. ï² Steam Generators
ï² Carbonated Bev. ï² Dental Equip. ï² Dye Vats
ï² Fume Hoods ï² Laboratory Equip. ï² Pressure Washers
ï² Degreasers ï² Autoclave/Sterilizers ï² Cooling Towers
ï² Hot Tub/Spa ï² Decorative Fountain ï² Fire Sprinkler
ï² Aquarium ï² Swimming Pools ï² Sprinkler w/chemicals
ï² Lawn Irrigation ï² Well on property ï² Other: ________________________
WASTEWATER DISCHARGE
Does the plumbing system currently have a grease interceptor? ï² Yes ï² No ï² Don’t Know
Does the plumbing system currently have an oil/water
ï² Yes ï² No ï² Don’t Know
separator?
REV03.2022 Page 6 of 7
COMMERCIAL TENANT IMPROVEMENT
Is water used in the business process (washing, rinsing,
ï² Yes ï² No ï² Don’t Know
cooling)?
Does your business require a NPDES permit? ï² Yes ï² No ï² Don’t Know
I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of
the above-described property will be in accordance with the laws, rules and regulation of the State of Washington.
Signature Print Name Date
REV03.2022 Page 7 of 7
ACCESSORY MOUNTING SCHEDULE
TOILET PAPER TOWEL
TOILET PAPER SANITARY NAPKIN 36" GRAB BAR 42" GRAB BAR 30" x 48" MIRROR VERTICAL GRAB
URINAL
DISPENSER
DISPENSER DISPOSAL BAR
39"- 41"
13½ min
ENSURE FLUSH VALVE
345
FACES "WIDE-SIDE" OF
ROOM
18"
7"- 9"
17 max
CL 40"
430
48" MAX. CL 30"
39"- 41"
40" MAX. TO DISP. SLOT
15" MIN. 33" MIN. 36" MAX.
17" MAX.
TO TOP OF SEAT
TO BOTTOM
EDGE OF REFLECTIVE SURFACE
TYP. REACH RANGES PER ICC A117.1
20 max >20-25 max
510 510-635
380
380 1220 1220 1170
1220 1220
15 min 48 max 48 max 1120
15 min 48 max 865 48 max 865 46 max
44 max
34 max 34 max
10 max
10 max > 10-24 max
255 255-610
255
TYP. KITCHEN DETAILS PER ICC A117.1
CASEWORK SECTION/ WORK SPACE @ COUNTER @ SINKS
COUNTER @ 34" COUNTER @ 36"
STORAGE RANGES
Date: 12/03/2025
Permit #: 6561
Permit Date: 06/16/2025
Review Date: 06/17/2025
Permit Type: COMMERCIAL ALTERATION
Review Type: COMMERCIAL ALTERATION
Target Date: 07/15/2025
Scheduled Time: 00:00
Completed Date: 06/25/2025
Description: Must provide Backflow protection before any branch lines from main line water.
Review Status: Approved with Conditions
Assigned To: BUILDING
Time In: 00:00
Time Out: 00:00
Hours: 0.5
Notes
06/25/2025 Must provide Backflow protection before any branch lines from main line water.
Property Information
Parcel#: 31052800102400 ARLINGTON 51ST ST LLC
ARLINGTON 51ST ST LLC PO BOX 619
4820 LONGHOUSE TRAIL LANE NE STE 106 SEDRO WOOLLEY, WA 98284
Zoning: 126 MULTI-FAMILY MKTLot: 6Block:
Permit #: 6561
Permit Date: 06/16/25
Permit Type: COMMERCIAL ALTERATION
Project Name: Laine Salon
Applicant Name: BYK Construction, Inc.
Applicant Address: PO Box 619
Applicant, City, State, Zip: Sedro Woolley, WA 98284
Contact: Anna Holleman
Phone: 425-610-5059
Email: Annah@bykconstruction.com
Scope of Work: Hair Salon
Valuation: 178000.00
Square Feet: 1155
Number of Stories: 1
Construction Type: VA
Occupancy Group: B; Business
ID Code:
Permit Issued: 07/01/2025
Permit Expires: 03/10/2026
Form Permit Type: COMMERCIAL ALTERATION
Status: COMPLETE
Assigned To: Hannah Hardwick
Property
Parcel # Address Legal Description Owner Name Owner Phone Zoning
4820 LONGHOUSE TRAIL ARLINGTON 51ST 126 MULTI-
31052800102400 BSP
LANE NE STE 106 ST LLC FAMILY MKT
Contractors
Contractor Primary Contact Phone Address Contractor Type License License #
CONSTRUCTION
BYK Construction Paul Woodmansee 360-661-5325 PO Box 619 COA 603187914
CONTRACTOR
CONSTRUCTION
BYK Construction Paul Woodmansee 360-661-5325 PO Box 619 L&I BYKCOCI886JB
CONTRACTOR
Inspections
Date Inspection Type Description Scheduled Date Completed Date Inspector Status
C20. BUILDING
11/07/2025 11/12/2025 11/12/2025 BUILDING Approved
FINAL
Hawken is the contact 360-
09/10/2025 C07. WALLBOARD 09/12/2025 09/12/2025 BUILDING Completed
466-8147
09/09/2025 C11. INSULATION 09/10/2025 09/10/2025 BUILDING Completed
Framing and mechanical
rough in
09/08/2025 C09. FRAMING 09/08/2025 09/08/2025 BUILDING Completed
Hawken is the contact, 360-
466-8147
C08. PLUMBING
08/25/2025 08/26/2025 08/26/2025 BUILDING Approved
ROUGH-IN
C04. PLUMBING
07/22/2025 07/23/2025 07/23/2025 BUILDING Approved
GROUNDWORK
Plan Reviews
Date Review Type Description Assigned To Review Status
COMMERCIAL No Comment
06/17/2025 AIRPORT
ALTERATION Received
COMMERCIAL Development
06/17/2025 No civil concerns Approved
ALTERATION Services Manager
COMMERCIAL
06/17/2025 No land use concerns. PLANNING Approved
ALTERATION
COMMERCIAL
06/17/2025 No comments, KS & LT PW-ADMIN-GIS Approved
ALTERATION
COMMERCIAL
06/17/2025 No comments, JW PW-SEW-REV Approved
ALTERATION
COMMERCIAL An RPBA for Premise Isolation is already installed for the
06/17/2025 PW-WAT-REV Approved
ALTERATION commercial portion of this building, Gus
COMMERCIAL Must provide Backflow protection before any branch lines Approved with
06/17/2025 BUILDING
ALTERATION from main line water. Conditions
Fees
Fee Description Notes Amount
Building Plan Review Table 4-2 $1,399.92
Processing/Technology $25.00
Building Permit Table 4-1 $2,153.72
State Surcharge - Commercial Commercial Only $25.00
Total $3,603.64
Attached Letters
Date Letter Description
07/01/2025 Building Permit
06/16/2025 Web Form - Building Application
Payments
Date Paid By Description Payment Type Accepted By Amount
XBP Conf:
06/17/2025 $1,399.92
234455048
XBP Conf:
07/01/2025 $2,203.72
235879561
Outstanding Balance $0.00
Notes
Date Note Created By:
Applicant says they wish to pause on issuing this permit until the lease is finalized with the
06/25/2025 Hannah Hardwick
tenant.
Uploaded Files
Date File Name
06/16/2025 f7bb6d3e99fc78c85c25b36e95c6c7c6_20814775-commercial_tenant_improvement_application.pdf
06/16/2025 f457108301a62a1fe8495ac037b3e544_outpost_site_plan_signed.pdf
06/16/2025 82749f0a8571f26aef1cd03e3cf39999_laine_salon_bldg_6_-_6-3-25_permit_set.pdf