HomeMy WebLinkAbout18520 67th Ave Ne_BLD6646_2025 425-244-1445 P.O. BOX 3711ARLINGTON, WA 98223LIC. BHFIRHF842KWPH: DESIGNER: JEFF BROSSARD NICET LEVEL 3 ID # 148093 LICENSE: BROSSJB951L7 REFERENCE: 2021 IFC AND 2019 NFPA 72 EXIT EXIT EXIT EXIT EXIT EXIT EXIT MONORAIL 18520 67TH AVE. NE SEATTLE GALVANIZINGARLINGTON SPIN LINEARLINGTON, WASHINGTON 98223 MONORAIL ISSUES REV DATE DESCRIPTION TITLE: FIRE ALARM PLAN MAIN FLOOR FIRE ALARM PLAN - MAIN FLOOR 1 SCALE: 1/16"=1'-0" DATE: JULY 13, 2025 PROJECT NO.: 25-020 SHEET: FA-1 Original Size: 24"x36" 425-244-1445 P.O. BOX 3711ARLINGTON, WA 98223LIC. BHFIRHF842KWPH: DESIGNER: JEFF BROSSARD NICET LEVEL 3 ID # 148093 LICENSE: BROSSJB951L7 REFERENCE: 2021 IFC AND 2019 NFPA 72 EXIT EXIT EXIT EXIT 18520 67TH AVE. NE EXIT EXIT EXIT SEATTLE GALVANIZINGARLINGTON SPIN LINEARLINGTON, WASHINGTON 98223 ISSUES REV DATE DESCRIPTION FIRE ALARM PLAN - ENLARGED MAIN FLOOR FIRE ALARM PLAN - SECOND FLOOR FIRE ALARM PLAN - THIRD FLOOR 1 2 3 SCALE: 1/8"=1'-0" SCALE: 1/8"=1'-0" SCALE: 1/8"=1'-0" TITLE: ENLARGED FIRE ALARM PLANS DATE: JULY 13, 2025 PROJECT NO.: 25-020 SHEET: FA-2 Original Size: 24"x36" 425-244-1445 P.O. BOX 3711ARLINGTON, WA 98223LIC. BHFIRHF842KWPH: EQUIPMENT LEGEND DESIGNER: JEFF BROSSARD NICET LEVEL 3 ID # 148093 LICENSE: BROSSJB951L7 REFERENCE: 2021 IFC AND 2019 NFPA 72 FIRE ALARM ONE-LINE RISER DIAGRAM SCALE: NONE WIRE LEGEND 18520 67TH AVE. NE SEQUENCE OF OPERATIONS DESIGNED AUDIBILITY LEVEL PER OCCUPANCY CLASSIFICATION SEATTLE GALVANIZINGARLINGTON SPIN LINE ARLINGTON, WASHINGTON 98223 GENERAL NOTES: ISSUES ANNUNCIATE SOUNDER ATFACP ANNUNCIATE SOUNDER ATREMOTE ANNUNCIATORTRIGGER BUILDINGAUDIBLE/VISUAL APPLIANCESWATERFLOW ALARM SIGNALTO CENTRAL STATIONALARM SIGNAL TO CENTRALSTATIONTROUBLE SIGNAL TOCENTRAL STATIONSUPERVISORY SIGNAL TOCENTRAL STATION REV DATE DESCRIPTION WATERFLOW DEVICE X X X X TAMPER DEVICE X X X BUILDING PULL STATION X X X X BUILDING SMOKE DETECTOR X X X X TITLE: AC POWER LOSS X X X FIRE ALARM LOW BATTERY X X X LEGENDS, NOTES AND RISER DIAGRAM DATE: JULY 13, 2025 PROJECT NO.: 25-020 SHEET: FA-3 Original Size: 24"x36" Global Project Values: Project Name: Seattle Galvanizing Arlington Spin Standby Hours: 24 Project ID: 25-296 Alarm Mins: 5 Prepared By: JEFF BROSSARD Derating Factor: 1.2 6808 Battery Calculator (SK) Date: 7/25/2025 Voltage Drop Warning Version 18.05.29 Threshold % : 10 Panel ID: 6808 Model: 6808 Add. Fire Alarm Control Panel Max NAC Current: 3.0 Amps Location: Sprinkler Riser Volts: 24 VDC Max Panel Current: 6.0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ Ckt.# Circuit Name Qty %Drop Standby Alarm & Type 1000 Ft. One-Way Ohms EOL 6808 6808 CTRL Panel 1 0.190 0.250 SK Photo, Photo-T, PhotoR 0.000 0.000 SK Heat, Heat-HT, ROR 0.000 0.000 SK Beam, Beam-T 0.000 0.000 SK Duct 0.000 0.000 SK Acclimate 0.000 0.000 SK FIRE-CO 0.000 0.000 SK-PHOTO-W Photo W 1 0.000 0.005 SK-PHOTO-R-W Photo-R-W 0.000 0.000 SK-PHOTO-T-W Photo-T-W 0.000 0.000 SK-HEAT-W Heat-W 0.000 0.000 SK-HEAT-ROR-WHeat-ROR-W 0.000 0.000 SK-HEAT-HT-W Heat-HT-W 0.000 0.000 SK Control 0.000 0.000 SK Control-6 0.000 0.000 SK RelayMon-2 0.000 0.000 SK Monitor, Minimon 4 0.002 0.020 SK Monitor-2 0.000 0.000 SK Monitor-10 0.000 0.000 SK Pull-SA, Pull-DA 1 0.000 0.005 SK Relay 0.000 0.000 SK Relay-6 0.000 0.000 N/A SK Zone 0.000 0.000 SK Zone-6 0.000 0.000 SK Isolator Module 0.000 0.000 B224BI Isolator Base 0.000 0.000 B200SR Sounder Base 0.000 0.000 B200S Intelligent Sounder Base 0.000 0.000 B200SR-LF Low Freq Sounder Base 0.000 0.000 B200S-LF Low Freq Sounder Base 0.000 0.000 B224RB Relay Base 0.000 0.000 RTS151 Magnetic Remote Test 0.000 0.000 RTS151KEY Key Activated Test 0.000 0.000 RA100Z Remote LED 0.000 0.000 5860 LCD Remote Annunc 0.000 0.000 5824 Serial/Parallel Module 0.000 0.000 5496 Power Expander 0.000 0.000 5895XL Power Expander 0.000 0.000 5865-4 LED Annunciator (4G) 0.000 0.000 5865-3 LED Annunciator (3G) 0.000 0.000 5880 LED Driver Module 0.000 0.000 5883 Relay Module 0.000 0.000 SK-NIC Network Input Card 0.000 0.000 SK-FML Muilti-Mode Fiber Card 0 0.000 0.000 SK-FSL Single-Mode Fiber Card 0 0.000 0.000 NAC #1 Office #### 0.000 0.369 #14 Solid 2.52 200 1.01 20.02 1.86% NAC #2 East Warehouse #### 0.000 1.032 #14 Solid 2.52 175 0.88 19.49 4.46% NAC #3 Middle Warehouse #### 0.000 0.756 #14 Solid 2.52 200 1.01 19.63 3.77% NAC #4 West Warehouse #### 0.000 0.756 #14 Solid 2.52 250 1.26 19.44 4.71% Total Standby Current (Amps) 0.192 0.000 Total Alarm Current (Amps) Standby Time In Hours 24 3.193 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 4.608 0.083 Total Alarm AH Required Total Combined AH Required 4.87 0.266 Command Shortcuts Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 5.85 Configure Circuits Print Page 7 AH PROVIDED Circuit Configuration Project Information Project Name: Seattle Galvanizing Arlington Spin Project ID: 25-296 Prepared By: JEFF BROSSARD Date: 7/25/2025 Ckt. Number: NAC #1 Panel ID: 6808 Ckt. Name: Office Use: Current Draw Each Current Draw Total Qty Device Standby Alarm Standby Alarm 9 P2WL 15CD LED 0.000 0.035 0.000 0.315 3 SWL 15CD LED 0.000 0.018 0.000 0.054 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.369 Ckt. Number: NAC #2 Panel ID: 6808 Ckt. Name: East Warehouse Use: Current Draw Each Current Draw Total Qty Device Standby Alarm Standby Alarm 1 P2GRK 75CD LED 0.000 0.087 0.000 0.087 5 PC2WL 150CD LED 0.000 0.189 0.000 0.945 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1.032 Ckt. Number: NAC #3 Panel ID: 6808 Ckt. Name: Middle Warehouse Use: Current Draw Each Current Draw Total Qty Device Standby Alarm Standby Alarm 4 PC2WL 150CD LED 0.000 0.189 0.000 0.756 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.756 Circuit Configuration Project Information Project Name: Seattle Galvanizing Arlington Spin Project ID: 25-296 Prepared By: JEFF BROSSARD Date: 7/25/2025 Ckt. Number: NAC #4 Panel ID: 6808 Ckt. Name: West Warehouse Use: Current Draw Each Current Draw Total Qty Device Standby Alarm Standby Alarm 4 PC2WL 150CD LED 0.000 0.189 0.000 0.756 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.756 6808 Addressable Fire Alarm Control Panel The 6808 is an addressable fi re alarm control panel (FACP) that can be confi gured to achieve an overall point capacity of up to 198 points. It has one built-in signaling line circuit (SLC), which can support 99 System Sensor® (SK) sensors and 99 SK modules or 127 Hochiki® (SD) devices per loop. A common communications and annunciation link allows up to 17 panels to be connected via copper or fi ber optic cable. A designated panel is confi gured as the communicator for all panels in the link for convenient single-point communications. It also has a built-in, dual- line POTs and IP communicator and optional cellular side-cars. 6808 The 6808 system can be enhanced by adding modules such as the 6860 remote annunciator which also has four programmable function It supports a variety of devices, including the buttons to help automate tasks and reduce time spent at the panel. 6860, 5860, and 6855 remote annunciators, 5824 serial parallel printer interface module (for SWIFT® wireless compatibility provides options for wireless detection printing system reports), the 5496 NAC expander, through a Class A mesh network. It is ideal for hard-to-wire locations, 5895XL power module, and SK or SD devices. buildings where new wiring is not allowed, or to provide an easy install fi re system for new construction projects. SWIFT devices can be combined with other hard-wired 6808 compatible devices. The 6808 also has Form C trouble relay, and two programmable Form C relays, along with powerful features such as drift compensation, pre- trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and calibration trouble alert. FE ATURES & BENEFITS • Capable of providing • Convenient • 6860 annunciator with • Programmable date • 125 software zones up to 198 points to fi eld-upgradeable a 4 x 40 large display, setting for automatic and 125 output satisfy smaller fi rmware and 4 programmable and convenient groups for fl exible installation needs function buttons. Daylight Saving Time design options • Integrated dual path Free-up time spent at changes • Connect up to 17 IP and POTs the panel. Program panels on one site with communications and • Built-in dual phone them for simple or convenient single- optional cellular line and digital alarm complex tasks. point access using the side-cars for reliable communicator/ SK-NIC Network backup • Built-in USB interface transmitter (DACT) for Interface Card. for convenient and additional Connected panels can quick programming communication have mixed compatible options FACP models. 6808 Product Information SIGNAL LINE CIRCUIT (SLC) non-coded) signaling services. The 6808 SLC loop supports multiple • UL Listed device types, maintenance alerts, and a • CSFM 7165-0559:0502 built-in sensor test to comply with NFPA 72 calibration testing requirements. • FDNY COA# 6246 • FM approved INDICATOR LIGHTS • Seismic (CA) (pending) • General Alarm (Red): Flashes if in alarm; solid when alarm is silenced 6808 KEYPAD ORDERING INFORMATION • Supervisory (Yellow): Flashes if a PROGRAMMING 6808: Addressable Fire Alarm supervisory condition exists; solid Control Panel. (Red cabinet). The 6808 system offers several options when supervisory is silenced to simplify and speed-up programming. COMPATIBLE ANNUNCIATORS • System Troubles (Yellow): Flashes JumpStart® AutoProgramming 6860: 4x40 LCD remote fire if a trouble condition exists; minimizes programming required to annunciator (4 lines and up to solid when trouble is silenced start a new system. The built-in keypad, 160 characters) per system; four • System Silenced (Yellow): or the 6860, 5860 or 6855 remote programmable buttons On when an alarm, trouble or annunciators give you on-site access 5860: 4x20 LCD remote fire supervisory condition has been to current system programming. You annunciator. 5860 is gray; 5860R is red silenced but not yet cleared can also program the system using the Honeywell Fire Software Suite 6855: 4x20 LCD remote fire • System Power (Green): Flashes (HFSS), which is Windows® based. annunciator for AC failure; solid when 5865-3 or 5865-4: LED annunciators power systems are normal SOFTWARE TOOLS can display up to 30 LEDs (15 red and USER INTERFACE SKST: Silent Knight Selection Tool 15 yellow). The 5865-4 has key switches provides the installer or design architect for silence and reset, and a system The 6808 built-in 4 x 20 annunciator with a Windows® software system trouble LED. with 80 character LCD display configuration tool to create a detailed and large easy-to-use tactile 5880: LED / IO module has 40 Bill of Material (BOM) and battery touchpad can be used for system programmable LED outputs and eight calculations. operation, programming and supervised dry contact inputs which are maintenance. It has five LEDs for HFSS: Honeywell Fire Software Suite useful for custom applications. You can alarm, supervisory, system trouble, provides communication and panel use up to eight 5880 modules on one system silenced and system power. programming, detector status, event control panel for maximum flexibility. history and additional data. Requires a Its compact size allows mounting inside System operations include silencing Windows-based computer. the annunciator, or in an accessory alarms and troubles, resetting alarms cabinet. and the display of alarm troubles and ADDITIONAL INFORMATION memory. The system's non-volatile Twisted-unshielded pair event history buffer stores 1,000 wire is recommended. events for viewing from the built- The 6808 also has 13 preset in or remote annunciator. System notification cadence patterns operations can be initiated with a (including ANSI 3.41). mechanical firefighter's key or a valid 4- to 7-digit operator's code. AGENCY LISTINGS AND APPROVALS NFPA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT 6808 COMPATIBLE DEVICES AND B200S-LF: Low-frequency intelligent smoke detector ACCESSORIES sounder base WSK-PHOTO-T: Wireless Multi-criteria See the data sheets listed below for a B224RB: Relay base photoelectric smoke detector with thermal complete listing of the SK, SD or SWIFT B224BI: Isolator base detection (135°F fixed temperture) and devices. B510W 4" base 53623: SK Devices Data Sheet SD COMPATIBLE ADDRESSABLE WSK-HEAT: Wireless Heat, (135°F fixed 53624: SD Devices Data Sheet DEVICES temperture) and B510W 4" base SD505-6AB: Addressable 6" base 350614, 350616 & 350618: SWIFT WSK-HEAT-ROR: Wireless heat, ROR wireless devices SD505-6IB: Addressable 6" short circuit (135°F fixed temperture) and B510W 4" isolator base base For a complete and current listing of compatible devices and accessories go to SD505-6RB: Addressable 6" relay base WSK-MONITOR: Wireless monitor module www.silentknight.com SD505-6SB: Addressable 6" sounder base WSK-RELAY: Wireless relay module Important: You cannot mix SK and SD SD500-AIM: Addressable input module W-USB: SWIFT Tools USB transceiver used devices in the same fire alarm system. (switch input) for communication with SWIFT devices SD500-ANM: Addressable notification SK COMPATIBLE ADDRESSABLE module SBUS ACCESSORIES DEVICES SD500-ARM: Addressable relay module 5496: A 6 amp notification power expander SK-ACCLIMATE: Multi criteria SD505-DTS-K: Remote test switch and with four power-limited notification photoelectric smoke detector with thermal LED indicator for the SD505-DUCTR appliance circuit outputs. 135°F fixed temperture SD505-DUCT: Addressable Duct Smoke 5883: Relay Interface. Provides 10 Form C SK-BEAM: Reflected beam smoke detector Detector. relays. without test feature SD505-DUCTR: Addressable Duct 5824: Serial/Parallel Printer Interface SK-BEAM-T: Reflected beam smoke Detector housing with relay base. Module for printer connection. detector with test feature SD505-HEAT: Absolute temperature 5895XL: Power Supply with six Flexput™ SK-CONTROL: Supervised control module heat detector. Trip point range from circuits, and two Form C relays. Max. 16 per SK-CONTROL-6: Six circuit supervised 135°F–150°F (0°C–37°C). system. control module SD500-LIM: Addressable Line isolator 5815RMK: Remote mounting kit. SK-DUCT: Photoelectric duct smoke module Dimensions: 10 3/8”W x 10-3/16”H x 3”D detector with extended air speed range SD500-MIM: Addressable Mini input SK-FIRE-CO: Four criteria fire and carbon COMMUNICATION OPTIONS monitor module (switch input) monoxide detector CELL-CAB-SK: Cellular communicator, SD505-PHOTO: Photoelectric smoke SK-HEAT: Fixed thermal detector (135°F) metal enclosure with lock/key* detector SK-HEAT-ROR: Fixed rate of rise detector SD500-PS/-PSDA: Addressable Single or CELL-MOD: Cellular communicator, plastic (135°F) enclosure* dual action pull station SK-HEAT-HT: Fixed high temperature *Sole path, powered by panel. SD500-SDM: Addressable smoke detector thermal detector (190°F) module IPGSM-4G: Dual path fire alarm SK-ISO: Fault isolator module communicator, cellular and/or IP (primary SK-MINIMON: Mini monitor module AUDIBLE/VISIBLE DEVICES or backup, selectable) SK-MONITOR: Monitor module These AV devices are all 2-wire. Color: “R” SK-IP-2: Remote reporting via the Internet. SK-MONITOR-2: Dual input monitor indicates red; “W” denotes white. For a Requires a VisorAlarm® receiver at the module complete listing of Silent Knight AV devices central station SK-MON-10: 10 input monitor module go to www.silentknight.com. CHSRL/CHSWL: Wall chime/strobe MISC. ACCESSORIES SK-PHOTO: Photoelectric smoke detector CHSCRL/CHSCWL: Ceiling chime/strobe SK-NIC: Network Interface Card. Provides SK-PHOTO-T: Photoelectric smoke a common communications link for the detector with thermal (135°F fixed CHRL/CHWL: Wall chime 6808. temperture) HRL/HWL: Wall horn SK-NIC-KIT: Installation Accessory Kit SK-PHOTOR: Photoelectric detector with P2RL/P2WL: Wall horn/strobe SK-FML: Fiber-Optic Multi Mode, remote test capability PC2RL/PC2WL: Ceiling horn/strobe transmitter and receiver SK-PULL-SA: Addressable single action SRL/SWL: Wall strobe SK-FSL: Fiber-Optic Single Mode pull station SCRL/SCWL: Ceiling strobe RBB: Remote battery box accessory cabinet SK-PULL-DA: Addressable dual action pull SPSCRL/SPSCWL: Ceiling speaker/strobe for batteries that are too large to fit in the station SPSRL/SPSWL: Wall speaker/strobe FACP cabinet. Dimensions: 16” W x 10” H x SK-RELAY: Addressable relay module SPRL/SPWL: Wall speaker 6” D (406mm W x 254mm H x 152mm D). SK-RELAY-6: Addressable Six relay control SPCRL/SPCWL: Ceiling speaker SK-SCK: Seismic Compliance Kit used to module securely fasten batteries to the fire panel. SK-RELAYMON-2: Addressable Dual relay/ SWIFT WIRELESS DEVICES monitor module SWIFT is only compatible with SK-ZONE: Addressable zone interface module System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. SK-ZONE-6: Six zone interface module B210LP: 6" mounting base WSK-WGI: Wireless Gateway B501: 4" Flangeless mounting base WSK-PHOTO: Wireless Photoelectric B200S: Intelligent sounder base 6808 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS (NACs) For a complete listing of all Overall Dimensions: 16.36”W x 26.37”H x 3.91”D Four programmable circuits which can be compliance approvals and certifications, please visit Shipping Weight: 32 lbs. programmed individually as: www.silentknight.com. Color: Red NACs: 3A @ 27.4VDC per circuit, power-limited (with a maximum current of 6A) Microsoft, Windows, and ENVIRONMENTAL Auxiliary Power Circuits: 3A @ 27.4VDC per circuit, the Windows Logo are registered trademarks Operating Temperature: 32°F to 120°F (0°C to power-limited or trademarks of 49°C) Microsoft Corporation. Humidity: 0 to 93% relative humidity (non- Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for the SLC Silent Knight®, Honeywell® condensing) and SWIFT® are registered trademarks of Honeywell ELECTRICAL WIRING: See the product manual for wiring details International, Inc 6808 Primary AC: 120 VAC @ 60Hz, 3.3A Total Accessory Load: 6A @ 27.4VDC power-limited This document is not intended to be used for Standby Current: 190mA installation purposes. We Alarm Current: 250mA try to keep our product Battery Charging Capacity: 7 to 35AH information up-to date and accurate. We Battery Size: 7AH to 18AH max. allowed in control cannot cover all specific panel cabinet. Larger capacity batteries can be applications or anticipate housed in RBB accessory cabinet. all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 351608 | A | 11/17 800-328-0103 © 2017 Honeywell International Inc. SK-PHOTO-W Series Intelligent Plug-In Photoelectric Smoke Detector Honeywell Silent Knight SK-PHOTO-W Series plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector’s address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test SK-PHOTO-W capable detector for use with DNR Series duct detector housings. FE ATURES & BENEFITS • New modern profile for • Dual LED design • Expanded color • Optional relay, improved aesthetics provides 360° viewing options isolator, and sounder angle bases • Stable communication • SEMS screws for technique with noise • Remote test feature wiring of the separate • Plugs into separate immunity from the panel base base for ease of installation and • Low standby current • Built-in functional test maintenance switch activated by • Two-wire SLC external magnet connection • Built-in tamper- • Optional remote, resistant feature single- gang LED accessory • Sealed against back pressure DETECTOR SPACING AND INTELLIGENT BASES ACCESSORIES APPLICATIONS B300-6: White, standard flanged CK300: Color Kit (includes cover and Honeywell recommends spacing low-profile mounting base. trim ring), white, 10-Pack. detectors in compliance with NFPA 72. B300-6-BP: Bulk pack of B300-6, CK300-IV: Color Kit (includes cover In low airflow applications with smooth package contains 10. and trim ring), ivory, 10-Pack. ceiling, space detectors 30 feet (9m). B300-6-IV: Ivory, standard flanged CK300-BL: Color Kit (includes cover For specific information regarding low-profile mounting base. and trim ring), black, 10-Pack. detector spacing, placement, and B501-WHITE: White, standard M02-04-01: Detector test magnet. special applications refer to NFPA 72. European flangeless mounting base. UL M02-09-00: Telescoping test magnet. System Smoke Detector Application listed. RA100Z: Remote LED annunciator Guide, document A05-1003, is available B501-BL: Black, standard European at systemsensor.com SMB600: Surface Mounting Kit flangeless mounting base. UL listed. (flanged). B501-IV: Ivory, standard European INSTALLATION TR300: Replacement trim ring for flangeless mounting base. UL listed. The SK-PHOTO-W Series plug-in B300-6, white. B200S-WH: White, Intelligent, detectors use a separate base to TR300-IV: Replacement trimring for programmable sounder base. simplify installation, service, and B300-6-IV, ivory. maintenance. Installation instructions B200S-IV: Ivory, Intelligent, are shipped with each detector. programmable sounder base. B200SR-WH: White, Intelligent sounder Mount base (all base types) on an base for retrofit applications. electrical backbox which is at least 1.5" B200SR-IV: Ivory, Intelligent sounder (3.81 cm) deep. base for retrofit applications. B200S-LF-WH: White, Low Frequency NOTE: Intelligent, programmable sounder • Because of the inherent supervision base. provided by the SLC loop, end-of-line B200S-LF-IV: Ivory, Low Frequency resistors are not required. Wiring Intelligent, programmable sounder “T-taps” or branches are permitted for base. Style 4 (Class “B”) wiring. B200SR-LF-WH: White, Low • When using relay or sounder bases, Frequency Intelligent sounder base for consult the installation sheet for device retrofit applications. limitations between isolator modules B200SR-LF-IV: Ivory, Low Frequency and isolator bases. Intelligent sounder base for retrofit applications. ORDERING INFORMATION B224RB-WH: White, plug-in System SK-PHOTO-W: Photoelectric smoke Sensor relay base. detector, white. B224RB-IV: Ivory, plug-in System SK-PHOTO-R-W: Photoelectric smoke Sensor relay base. detector, remote test capable, for use B224BI-WH: White, plug-in System with DNR(W) duct smoke detectors, Sensor isolator detector base. white. B224BI-IV: Ivory, plug-in System SK-PHOTO-T-W: Photoelectric smoke Sensor isolator detector base. detector with thermal sensing, white. SK-PHOTO-W Series Detector Technical Specifications PHYSICAL COMPATIBILITY For a complete listing of all compliance approvals and Height: 2.0" (51mm) installed in B300-6 base The SK-PHOTO-W series detectors are certifications, please visit compatible with the following Honeywell Silent www.silentknight.com. Diameter: 6.2" (156mm) installed in B300-6 base 4.1" (104 mm) installed in B501 base Knight fire alarm control panels: Microsoft, Windows, and the Windows Logo are Weight: 3.4 oz (95 g) 6820: Addressable fire alarm control panel registered trademarks or trademarks of 6820EVS: Addressable fire alarm control panel ENVIRONMENTAL Microsoft Corporation. with an emergency voice system. Operating Temperature range: Silent Knight®, System 6808: Addressable fire alarm control panel Sensor® and Honeywell® Photo: 32°F to 122°F (0°C to 50°C) are registered 6700: Addressable fire alarm control panel trademarks of Honeywell Photo with Thermal: 32°F to 100°F (0°C to International, Inc. 5700: Addressable fire alarm control panel 38°C) This document is not 5808: Addressable fire alarm control panel UL listed Velocity range: Photo/Photo with intended to be used for 5820XL: Addressable fire alarm control panel installation purposes. We Thermal: 0 to 4,000 fpm (0 to 20 m/sec) try to keep our product (suitable for installation in ducts) 5820XL-EVS: Addressable fire alarm control information up-to date and accurate. We Humidity: 10% to 93% non-condensing panel with an emergency voice system cannot cover all specific applications or anticipate Thermal Ratings: Fixed Temperature Set point: AGENCY LISTINGS AND APPROVALS all requirements. All 135°F (57°C) For exact certification listings for each model, specifications are subject please reference the respective agency Web site. to change without notice. ELECTRICAL RATINGS UL listed: S6173 For Technical Support, FM approved call 800-446-6444. Voltage Range: 15 to 32VDC peak CSFM: 7272-0559:0523 Operating Current @ 24VDC: 200µA (one communication every 5 seconds with green LED blink on communication) Maximum Current: 4.5mA @ 24VDC (one communication every 5 seconds with amber LED solid on). For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 Doc 351634 | Rev A | 04/18 800-328-0103 © 2018 Honeywell International Inc. INTELLIKNIGHT ACCESSORY SK-Pull-SA and SK-Pull-DA Intelligent Pull Stations The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition • Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition SK-Pull-SA • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Meets ADA requirement for 5 lbs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® • Reliable analog communications for trouble-free operation • Braille text on station handle SK-Pull-DA • Handle latches in down position and the word Activated Compatibility appears, clearly indicating the station has been pulled The SK-Pull-SA and SK-Pull-DA are compatible with the following IntelliKnight FACP’s: • Rotary address switches for fast installation 5600 • UL Listed, including UL 38, Standard of Manually Actuated 5700 Signaling System 5808 5820XL INTELLIKNIGHT ACCESSORY Model SK-Pull-DA and SK-Pull-SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans, Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. Specifications Electrical Operating Voltage: 15–32 VDC Physical Height: 5.5” (14 cm) Average Operating Current (LED flashing): 300 µA Width: 4” (10.2 cm) Wire Gauge: Up to 12 AWG (3.1 mm2) Depth: 5.4 oz. (3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 32º – 120ºF (0ºC – 49ºC) Bi-Colored LED: Humidity: 10% – 93% non-condensing Blinking Green: Normal Steady Red: Alarm Accessories Switch: Single pole, single throw (SPST) normally open (N/O) BG-TR Optional trim ring. switch which closes upon activation of the pull station SB-I/O Surface backbox This document is not intended to be used for installation purposes. We try MADE IN AMERICA to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350135 Rev B subject to change without notice. For more information, contact Silent © 2012 Honeywell International Inc. Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com INTELLIKNIGHT ACCESSORY SK-Monitor Intelligent Monitor Module The SK-Monitor module provides an interface to contact devices, such as security contacts, waterflow switches, or pull stations. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Monitor is an addressable monitor module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK-Monitor is intended for use in intelligent, two-wire systems, where individual address of each module is selected using the built-in rotary switches. The SK-Monitor supports Class A supervised or Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. Features • Single contact monitor • Support for Class A and Class B wiring • Fully supervised • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Attractive ivory cover plate SK-Monitor • Rotary address switches for fast installation • SEMS screws for easy wiring Specifications • UL Listed Physical Height: 4.5” (11.4 cm) Installation Width: 4” (10.2 cm) The SK-Monitor mounts directly into a 4” square electrical box. The box must have a minimum depth of 2-1/8”. A Depth: 1.25” (3 cm) surface mount electrical box (System Sensor® PN Shipping Weight: 6.3 oz (196 g) SMB500) is available from Silent Knight. Electrical Compatibility Operating Voltage: 15 – 32 VDC The SK-Monitor is compatible with the following Current Draw (LED on): 5.0 mA max IntelliKnight FACP’s: Operating Current (LED flashing): 375 µA 5700 5808 5820XL 5820XL-EVS INTELLIKNIGHT ACCESSORY Model SK-Monitor Intelligent Monitor Module 2-Wire Initiating Circuit Configuration, NFPA Style B 4-Wire Initiating Circuit Configuration, NFPA Style D Standby Current: Environmental 400 µA max @ 24 VDC (one communication every 5 Operating Temperature: 32ºF – 120ºF (0ºC – 49ºC) sec with 47K EOL) Humidity: 10% – 93% non-condensing 550 µA max @ 24 VDC (one communication every 5 sec with EOL <1K) Ordering Information 5.5 mA (with LED latched on) SK-Monitor Monitoring Module LED Current: 5.5 mA (with LED latched on)End-of-Line Resistance: 47K W Accessories Initiating Device Circuit Wiring Resistance: 1,500 W max SMB500 4” Square Surface Mount Electrical Box SLC Loop Resistance: 40 W max. This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight FORM# 350131 Rev D 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, © 2013 Honeywell International Inc. Fax: (203) 484-7118. For Technical Support, Please call 8200-446-6444. www.silentknight.com L-Series and L-Series with LED Indoor Selectable Horns, Strobes and Horn Strobes System Sensor L-Series and L-Series with LED audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series and L-Series with LED • LED technology provides lower current draw platform offers the most versatile and easy-to-use line of horns, • Digital Voltage Meter (DVM) diagnostic test points for Horn strobes, and horn strobes in the industry with lower current draw and Strobes and Strobes modern aesthetics. LED lighting technology offers significantly lower • Common aesthetics across the L-Series platform current draw compared to older Xenon bulbs across a full candela • Standard and compact sizes range. This improves design flexibility for notification appliance • Tamper-resistant construction circuits (NACs) while also reducing power supply requirements allowing for simpler and lower cost installations. • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 Flexible design options meet virtually any application requirement: • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, wall or ceiling mount, standard or compact sizes, red or white color 115, 150, and 177 choices, bezel kits for alternate markings and languages, and LED • Rotary switches for candela, tone and volume selections color lenses for distinctive visual signaling. In addition, installers can • Mounting plate provides plug-in design for easier installation and easily adapt devices using field selectable candela, tone and volume shorting springs to check wiring continuity settings using rotary switches. • Electrically compatible with legacy SpectrAlert, SpectrAlert Advance and L-series devices The L-Series and L-Series with LED line is developed to simplify installation. All devices feature plug-in designs with minimal intrusion • Synchronization through use of UL approved power supplies that into the back box, making installations fast and foolproof while support System Sensor Sync protocol or System Sensor MDL3 Sync Module virtually eliminating costly and time-consuming ground faults. The universal mounting plate includes an onboard shorting spring, so • Horns, Strobes and Horn Strobes listed for wall or ceiling use installers can test wiring continuity before the device is installed. In addition, the System Sensor L-Series with LED notification appliances offer a new diagnostic test point feature that allows you Agency Listings to measure device voltage with a digital voltage meter (DVM) without removing the appliance from the wall or ceiling. The DVM test points are discreetly located on the face of the notification appliance which enable faster troubleshooting and end of line (EOL) voltage checks Horn Strobes Horns: Horns: 3057072 7300-1653:0525 while greatly reducing the risk of misplacing or damaging appliances and Strobes: S4011 S4011 FM23FPUS0195 7135-1653:0503 during troubleshooting. S5512, S4011 7135-1653:0526 AVDS916-01 • 10/03/2023 • Page 1 L-Series and L-Series with LED Specifications Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage, LED Strobes and Horn Strobes Regulated 24 VDC Nominal Voltage, Horns Regulated 12 VDC or regulated 24 DC/FWR Operating Voltage Range, LED Strobes and Horn Strobes 16 to 33 V (24 V nominal) Operating Voltage Range, Horns 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG UL/ULC Current Draw Data, Horn Tones, and Sound Output Data UL/ULC Maxmimum Strobe Current Draw (mA) UL/ULC Maxmimum Horn Current Draw (mA RMS) Candela 16–33 Volts 8–17.5 Volts 16–33 Volts Rating Wall Ceiling Sound Pattern dB DC DC FWR Candela 15 18 18 Temporal High 39 44 54 Range 30 22 22 Temporal Low 28 32 54 75 70 70 Non-Temporal High 43 47 54 95 75 75 Non-Temporal Low 29 32 54 110 85 — 3.1 KHz Temporal High 39 41 54 115 — 90 3.1 KHz Temporal Low 29 32 54 135 105 — 3.1 KHz Non-Temporal High 42 43 54 150 — 110 3.1 KHz Non-Temporal Low 28 29 54 177 — 115 Coded High 43 47 54 185 120 — 3.1 KHz Coded High 42 43 54 UL/ULC Maximum Horn Strobe Current Draw (mA) and Sound Output (dBA) Current Draw (mA RMS), Horn Strobe, Sound Candela Range (15-185 cd) Output (dBA) 16-33 Volts 16-33V Switch Volume 15cd 30cd 75cd 95cd 110cd 115cd 135cd 150cd 177cd 185cd DC Pos. Sound Pattern Setting WALL CEILING WALL CEILING CEILING WALL 1 Temporal 3 High 35 38 87 92 94 120 189 189 190 190 87 2 Temporal 3 Low 35 38 87 92 94 120 135 135 145 145 79 3 Non-Temporal High 50 52 87 92 94 120 127 127 135 135 87 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 79 5 3.1KHz Temporal 3 High 35 38 87 89 91 115 155 155 165 165 86 6 3.1KHz Temporal 3 Low 35 38 87 89 91 115 128 130 135 135 80 7 3.1KHz Non-Temporal High 40 42 87 89 91 115 125 125 135 135 86 8 3.1KHz Non-Temporal Low 35 38 87 89 91 115 120 120 130 130 80 AVDS916-01 • 10/03/2023 • Page 2 L-Series with LED Dimensions: Wall-Mounted Equipment 2.07" 3.46" (53 mm) 3.57" 1.55" 3.46" 88 mm 1.25" 88 mm 1.25" 32 mm (9.1 cm) (3.9 cm) (31.8 mm) 5.38" 5.27" 5.27" (13.7 cm) 133.9 mm 133.9 mm A0617-00 A0547-00 A0557-00 Compact Strobe, Horn Strobe Compact Horn Compact Surface Mount Back Box for Wall for Walls (SBBGRL, SBBGWL) 2.07" 4.7" 4.7" (53 mm) 1.25" 119 mm 1.25" 119 mm 4.82" 32 mm 1.85" (31.8 mm) (12.24 cm) (4.69 cm) 5.67" 5.67" 144 mm 5.78" 144 mm (14.68 cm) A0613-00 A0549-00 A0554-01 Strobes, Horn Strobes Horn Surface Mount Back Box for Walls for Walls ( SBBRL/SBBWL) L-Series with LED Dimensions: Ceiling-Mounted Equipment 6.92" diam. 2.5" 2.07" (175.77 mm) (64 mm) (52.6 mm) 6.83" diam. 1.25" (173.5 mm) (31.8 mm) A0608-00 A0546-00 Strobes and Horn Strobes Surface Mount Back Box for Ceilings for Ceilings (SBBCRL, SBCWL) AVDS916-01 • 10/03/2023 • Page 3 L-Series with LED: Ordering Information Model Description Model Description L-Series with LED Horn Strobes LED Lenses P2RLED 2-Wire, Horn Strobe, Wall, Red LENS-A3 Lens LED Amber Wall/Ceiling P2RLED-B 2-Wire, Horn Strobe, Wall, Red, Bilingual LENS-B3 Lens LED Blue Wall/Ceiling P2WLED 2-Wire, Horn Strobe, Wall, White LENS-G3 Lens LED Green Wall/Ceiling P2WLED-B 2-Wire, Horn Strobe, Wall, White, Bilingual LENS-R3 Lens LED Red Wall/Ceiling P2GRLED 2-Wire, Compact Horn Strobe, Wall, Red Accessories P2GRLED-B 2-Wire, Compact Horn Strobe, Wall, Red, Bilingual TR-2 Universal Wall Trim Ring Red P2GWLED 2-Wire, Compact Horn Strobe, Wall, White TR-2W Universal Wall Trim Ring White P2GWLED-B 2-Wire, Compact Horn Strobe, Wall, White, SBBRL Wall Surface Mount Back Box, Red Bilingual SBBWL Wall Surface Mount Back Box, White P2RLED-P 2-Wire, Horn Strobe, Wall, Red, Plain SBBGRL Compact Wall Surface Mount Back Box, Red P2WLED-P 2-Wire, Horn Strobe, Wall, White, Plain SBBGWL Compact Wall Surface Mount Back Box, White P2RLED-SP 2-Wire, Horn Strobe, Wall, Red, FUEGO TRC-2 Universal Ceiling Trim Ring, Red P2WLED-SP 2-Wire, Horn Strobe, Wall, White, FUEGO TRC-2W Universal Ceiling Trim Ring, White PC2RLED 2-Wire, Horn Strobe, Ceiling, Red SBBCRL Ceiling Surface Mount Back Box, Red PC2RLED-B 2-Wire, Horn Strobe, Ceiling, Red, Bilingual SBBCWL Ceiling Surface Mount Back Box, White PC2WLED 2-Wire, Horn Strobe, Ceiling, White Bezels† PC2WLED-B 2-Wire, Horn Strobe, Ceiling, White, Bilingual BZR Wall Red Bezel Kit L-Series with LED Strobes BZW Wall White Bezel Kit SRLED Strobe, Wall, Red BZGR Compact Wall Red Bezel Kit SRLED-B Strobe, Wall, Red, Bilingual BZGW Compact Wall White Bezel Kit SWLED Strobe, Wall, White BZRC Horn Strobe Ceiling Red Bezel Kit SWLED-B Strobe, Wall, White, Bilingual BZWC Horn Strobe Ceiling White Bezel Kit SGRLED Strobe, Compact, Wall, Red SGRLED-B Strobe, Compact, Wall, Red, Bilingual Notes for L-Series With LED Horn Strobes and Strobes: SGWLED Strobe, Compact, Wall, White All -P models have a plain housing (no “FIRE” marking on cover). All -SP models have “FUEGO” marking on cover. SGWLED-B Strobe, Compact, Wall, White, Bilingual All -ALERT models have “ALERT” marking on cover. SRLED-P Strobe, Wall, Red, Plain All -B models have “FIRE/FEU” marking on cover for use in Canadian SWLED-P Strobe, Wall, White, Plain applications. Amber lenses are not for use in Canadian applications SRLED-SP Strobe, Wall, Red, FUEGO SWLED-CLR- Strobe, Wall, White, ALERT Notes for L-Series Horns: ALERT *Horn-only models are listed for wall or ceiling use. SWLED-ALERT Strobe, Wall, White, ALERT, Amber Lens SCRLED Strobe, Ceiling, Red Notes for Bezels: †Each bezel pack ships in a package of 5. SCRLED-B Strobe, Ceiling, Red, Bilingual Add one of the following extensions for print/language options: -F (FIRE), -AL SCRLED-P Strobe, Ceiling, White, Plain (ALERT), -EV (EVAC), -AG (AGENT), -P (Plain), -FR (FEU), -PG (FOGO), -SP SCWLED Strobe, Ceiling, White (FUEGO), -SPE (FUEGO/FIRE). SCWLED-B Strobe, Ceiling, White, Bilingual SCWLED-P Strobe, Ceiling, White, Plain SCWLED-CLR- Strobe, Ceiling, White, ALERT ALERT L-Series Horns HRL* Horn, Red HRLA* Horn, Red, Plain, ULC HWL* Horn, White HWLA* Horn, White, Plain, ULC HGRL* Compact Horn, Red HGRLA* Compact Horn, Red, Plain, ULC HGWL* Compact Horn, White HGWLA* Compact Horn, White, Plain, ULC 3825 Ohio Avenue • St. Charles, IL 60174 USA System Sensor® is a registered trademark of Honeywell International, Inc. Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com 3333 Unity Drive, Mississauga, ON L5L 3S6 Canada ©2023 System Sensor. Phone: 800-SENSOR2 • Fax: 905-812-0771 Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. www.systemsensor.ca AVDS916-01 • 10/03/2023 L-Series Outdoor Horns and L-Series with LED Outdoor Strobes and Horn Strobes System Sensor L-Series and L-Series with LED Outdoor audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series Outdoor and L-Series with LED Outdoor platforms offer the most versatile and easy-to-use • Weatherproof per NEMA 4X, IP56 as a standalone device line of Weatherproof Horns, Horn Strobes, and Strobes that can meet • Rated from –40°F to 151°F virtually any application requirement, including indoor, outdoor, wet, dry, and washdown environment applications in temperatures from • Electrically compatible with Legacy SpectrAlert Advance and −40°F to 151°F. SpectrAlert devices at 16-33 VDC • Field-selectable candela settings on wall units: 15, 30, 75, 95, The L-Series Outdoor and L-Series with LED Outdoor appliances 110, 135, and 185 are NEMA 4X and IP56 rated without having to seal the backbox. Additional caulk or sealant are not required on the backbox for a • Field-selectable candela settings on celiling units: 15, 30, 75, 95, faster, cleaner installation. The L-Series platform offers a modern 115, 150, and 177 aesthetic across the Indoor and Outdoor platform and design • Rotary switches for candela, horn, and volume variations across applications: wall or ceiling mount, red or white • Mounting plates with wirenuts are provided to make the color choices, LED colored lenses for distinctive visual signaling. connection between the field wiring and the mounting plates In addition, installers can easily adjust appliances through field • Synchronization through use of UL approved power supplies selectable candela, tone, and volume selections using rotary that support System Sensor Sync or System Sensor MDL Sync switches. Module LED technology offers significantly lower current draw compared • Tamper-resistant construction to older Xenon bulbs across a full candela range. This improves • Listed for ceiling or wall mounting design flexibility for notification appliance circuits (NACs) while also reducing power supply requirements allowing for simpler and lower • Compact size for Wall Mount cost installations. UL listed waterproof wirenuts are provided to make the connection between the field wiring and the mounting plates. Outdoor devices ship with plastic back boxes that accommodate in-and-out wiring for daisy chaining devices. Knock-outs located Agency Listings on the back eliminate the need to drill holes for screw-in mounting. Note: When replacing SpectrAlert Advance products, the backbox should be updated to the L-Series with LED backbox. Horns: S4011 3057072 7125-1653:0537 Horn Strobes and Strobes: FM23FPUS0195 7300-1653:0536 S4011, S5512 7125-1653:0535 7135-1653:0534 AVDS-62173:A • 08/29/2024 • Page 1 Product Specifications Physical/Electrical Specifications Standard Operating Temperature -40°F to 151°F (-40°C to 66°C) Humidity Range 0 to 95 ±5% Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 24 VDC Operating Voltage Range 16 to 33 V (24 V nominal) Wiring between Fire Alarm Control Panel (FACP) and weatherproof 12 to 18 AWG back plate Environmental Considerations Devices meet rating requirements for NEMA 4X, Type 4X, and IP56 as a standalone device Dimensions Wall Strobes and Horn Strobes (including lens) 5.84” L 3.76” W x 1.56” D (148mm x 95.5mm x 39.6mm) Wall Strobes and Horn Strobes (including lens) with SBBGRL/WL 5.84” L x 3.76” W x 3.72” D (148mm x 95.5mm x 94.5mm) Surface Mount Back Box Ceiling Strobes and Horn Strobes (including lens) 6.8” diameter x 2.22” D (173mm x 56.4mm) Ceiling Strobes and Horn Strobes (including lens) with SBBCRL/ 6.98” diameter x 4.72” D (177.3mm x 120mm) WL Surface Mount Back Box Wall Horns 5.84” L x 3.76” W x 1.56” D (148mm x 95.5mm x 39.6mm) Wall Horns with SBBGRL/WL Surface Mount Back Box 5.84" L x 3.76" W x 3.11" D (148mm x 95.5mm x 79mm) NOTE: SBBGRL/WL Surface Mount Back box intended for horns, horn strobes, and strobes. UL/ULC Maximum Strobe Current Draw (mA) UL/ULC Maximum Horn Current Draw (mA RMS) UL/ULC Maximum Horn Current Draw (mA) and Sound UL/ULC Maximum Horn Current Draw (mA) and Sound Output (dBA) Output (dBA) Current Draw Sound Candela Rating 16 to 33 Volts DC (mA RMS), Output 15 18 Horn (dBA) 30 22 16-33 16-33 Volume Pos Sound pattern Volts Volts 75 70 Setting (dB) DC DC 95 75 1 Temporal High 35 85 110 85 2 Temporal Low 35 77 115 90 3 Non-Temporal High 50 85 135 105 4 Non-Temporal Low 35 77 150 110 5 3.1KHz Temporal High 35 82 177 115 6 3.1KHz Temporal Low 35 75 185 120 7 3.1KHz Non-Temporal High 40 82 FCP* (future) 8 3.1KHz Non-Temporal Low 35 75 *FCP Fire Control Panel, future use UL/ULC Maximum Horn Strobe Current Draw (mA) and Sound Output (dBA) Sound Current Draw (mA RMS), Horn Strobe, Output Candela Range (15-185 cd) (dBA) 16-33 Volts 16-33 V Volume Pos Tone 15cd 30cd 75cd 95cd 110cd 115cd 135cd 150cd 177cd 185cd DC Setting WALL CEILING WALL CEILING CEILING WALL 1 Temporal High 35 38 87 92 94 120 189 189 190 190 85 2 Temporal Low 35 38 87 92 94 120 135 135 145 145 77 3 Non-Temporal High 50 52 87 92 94 120 127 127 135 135 85 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 77 5 3.1KHz Temporal 3 High 35 38 87 89 91 115 155 155 165 165 82 6 3.1KHz Temporal 3 Low 35 38 87 89 91 115 128 130 135 135 75 7 3.1KHz Non-Temporal High 40 42 87 89 91 115 125 125 135 135 82 8 3.1KHz Non-Temporal Low 35 38 87 89 91 115 120 120 130 130 75 AVDS-62173:A • 08/29/2024 • Page 2 L-Series with LED Outdoor Dimensions: Wall-Mounted Equipment A0547-00 A0557-00 Outdoor Compact Wall Horn with Outdoor Compact Wall Horn with Compact Surface Mount Back Box (SBBGRL/SBBGWL) Compact Surface Mount Back Box (SBBGRL/SBBGWL) A0613-00 A055v4-01 Outdoor Compact Strobes, Horn Strobes for Wall with Outdoor Compact Strobes, Horn Strobes for Wall with Compact Surface Mount Back Box (SBBGRL/SBBGWL) Compact Surface Mount Back Box (SBBGRL/SBBGWL) L-Series with LED Outdoor Dimensions: Ceiling-Mounted Equipment A0608-00 A0546-00 Strobes, Horn Strobes for Ceilings with Surface Strobes, Horn Strobes for Ceilings with Mount Back Box (SBBCRL/SBBCWL) Surface Mount Back Box (SBBCRL/SBBCWL) AVDS-62173:A • 08/29/2024 • Page 3 L-Series with LED Outdoor: Ordering Information Model Description Model Description L-Series with LED Outdoor Horn Strobes LED Lenses P2GRKLED 2-Wire, Compact Horn Strobe, Wall, Red LENS-A3 Lens LED Amber Wall/Ceiling P2GRKLED-P 2-Wire, Compact Horn Strobe, Wall, Red, Plain LENS-B3 Lens LED Blue Wall/Ceiling P2GRKLED-B 2-Wire, Compact Horn Strobe, Wall, Red, Bilingual LENS-G3 Lens LED Green Wall/Ceiling P2GWKLED 2-Wire, Compact Horn Strobe, Wall, White LENS-R3 Lens LED Red Wall/Ceiling P2GWKLED-P 2-Wire, Compact Horn Strobe, Wall, White, Plain Accessories P2GWKLED-B 2-Wire, Compact Horn Strobe, Wall, White, SBBGRL Compact Wall Surface Mount Back Box, Red Bilingual SBBGWL Compact Wall Surface Mount Back Box, White PC2RKLED 2-Wire, Horn Strobe, Ceiling, Red SBBCRL Ceiling Surface Mount Back Box, Red PC2RKLED-P 2-Wire, Horn Strobe, Ceiling, Red, Plain SBBCWL Ceiling Surface Mount Back Box, White PC2RKLED-B 2-Wire, Horn Strobe, Ceiling, Red, Bilingual Notes for L-Series With LED Outdoor Horn Strobes and Strobes: PC2WKLED 2-Wire, Horn Strobe, Ceiling, White All -P models have a plain housing (no “FIRE” marking on cover). PC2WKLED-P 2-Wire, Horn Strobe, Ceiling, White, Plain All -SP models have “FUEGO” marking on cover. PC2WKLED-B 2-Wire, Horn Strobe, Ceiling, White, Bilingual All -ALERT models have “ALERT” marking on cover. L-Series with LED Outdoor Strobes All -B models have “FIRE/FEU” marking on cover for use in Canadian applications. SGRKLED Compact Strobe, Wall, Red SGRKLED-P Compact Strobe, Wall, Red, Plain SGRKLED-B Compact Strobe, Wall, Red, Bilingual SGWKLED Compact Strobe, Wall, White SGWKLED-P Compact Strobe, Wall, White, Plain SGWKLED-B Compact Strobe, Wall, White, Bilingual SCRKLED Strobe, Ceiling, Red SCRKLED-P Strobe, Ceiling, Red, Plain SCRKLED-B Strobe, Ceiling, Red, Bilingual SCWKLED Strobe, Ceiling, White SCWKLED-P Strobe, Ceiling, White, Plain SCWKLED-B Strobe, Ceiling, White, Bilingual L-Series Outdoor Horns HGRKL Compact Horn, Red HGRKL-B Compact Horn, Red, Bilingual 3825 Ohio Avenue • St. Charles, IL 60174 USA System Sensor® is a registered trademark of Honeywell International, Inc. Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com 3333 Unity Drive, Mississauga, ON L5L 3S6 Canada ©2024 System Sensor. Phone: 800-SENSOR2 • Fax: 905-812-0771 Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. www.systemsensor.ca AVDS-62173:A • 08/29/2024 aes-corp.com 7707 Fire Subscribers A Newer, Smarter Alarm Communications Platform Feature Highlights • Leverages state of the art technology • Applies advanced security protection • Offers flexible power and configuration options • Engineered for backward compatibility with legacy systems • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button • Includes robust Multiple Communication Technologies (MCT) feature • Emulates virtual keypad • Improves functionality with an adaptive Graphic User Interface (GUI) for programming via smartphones, tablets and PCs • Plus many more… Key Benefits • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password-protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FACP) without requiring an electrician onsite and without Subscriber backup battery; (2) Directly from the FACP with Subscriber backup battery; or (3) Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards www.aes-corp.com Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option, they are the ideal drop-in replacement for Plain Old Telephone Service (POTS) lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status. The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop, tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or having to use a handheld programmer. Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add-on accessory board. AES subscribers’ intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming. A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units. A FACP Power Supply Adapter is required for certain configurations when using flexible power options. The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: aes-corp.com/products/fire/fire-marshal-resources www.aes-corp.com How to Order 7707 Fire IntelliNet 2.0 Fire Subscribers 2.0 PREMIUM (UL & ULC Listed) IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies 7707P-88-M (MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated 7707P-88-ULP-M onboard Local Annunciator plus MCT, Red Enclosure IntelliNet 2.0 Fire Subscriber, 4x4 Zone (4 Reversing Polarity, 4 Supervised) with 7707P-44-M Multiple Communication Technologies (MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 4x4 Zone (4 Reversing Polarity, 4 Supervised) 7707P-44-ULP-M with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 2.0 ACCESSORIES Standalone AES-IntelliPro Fire full data module add-on accessory board with 7794A firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy Fire Subscribers 7706-ULF Integrated Fire Monitoring System, Red Enclosure Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro (7794 full data module, 7788F-ULP-P 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, 7788F-ULP Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure Legacy Fire Subscriber, 4 Zone with 7795 AES-IntelliPro (7794 full data module, 7744F-ULP-P 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure Legacy Fire Subscriber, 4x4 Zone, 4 Supervised Zones with 7794 AES-IntelliPro, 7744F-ULP Red Enclosure Legacy Fire Subscriber, 4x4 Zone, 4 Reversing Polarity, 4 Supervised Zones, 7744F Red Enclosure LEGACY ACCESSORIES Standalone AES-IntelliPro Fire full data module add-on accessory board for legacy 7794 units only, please see 7794A above for IntelliNet 2.0 version www.aes-corp.com Technical Specifications 7707 Fire D I M EN S I O N S AL AR M S I G NAL I N P U T S / ZO N E S P OR T S 13”H x 8.5”W x 4.5”D · 8 individually programmable Ethernet for configuration (33cmH x 21.5cmW x 11.4cmD) E.O.L. type zone inputs and message communication · 4+4: 4 reverse polarity input and USB access for software upgrade W EI G H T 4 individually programmable 5.8 lbs (2.6 kilograms) E.O.L. type zone inputs R E M O T E A N NUN C I AT OR excluding battery · Optional 7794A AES-IntelliPro for AES Model 7740 13 lbs (5.9 kilograms) with full data via Contact ID, Pulse, Remote Annunciator, supervised 10 Ah battery Modem IIe and Modem IIIa2 CO MPAT I B L E R E C EI V E R S R A D I O F R E QUE N C Y UL LI S T I NG S 7705i AES-MultiNet Receiver Standard Frequency Range: UL 864 10th Edition 450-470 MHz Standard for Control Units and CO N FI GU R AT I O N I N T ER FA CE Contact AES for other UHF Accessories for Fire Alarm Systems Web browser capable device and VHF frequencies ULC S559-04 1st Edition accessible via smartphone, tablet, Equipment for Fire Signal laptop, or PC A NT E N N A Receiving Centres and Systems 2.5 dB tamper resistant antenna C UR R E N T CON S UM P T I ON included, mounts on enclosure Standby w/ charged backup battery: Optional remote mounting T R OUB LE OU T P U T— A C K 200 mA (1.2 A Transmitting) antenna available DEL AY/A N T EN N A C U T Standby + charging backup battery: Form C relay, fail secure, rated 24V 900 mA (1.9 A Transmitting - MAX) P O W ER I N P U T DC 1A resistive, unsupervised AC SOURCES P O WE R O UT P UT Transformer: Class 2 R E S E T BU T T O N 2 or 5 Watts 16.5V AC nominal output Located on main circuit board Factory set 1.9 A max current (40 VA MIN) ELK ELK-TRG1640, O P ER AT I N G T EM P ER AT U R E EN CL O SU R E M AT ER I A L MG ELECTRONIC SALES MGT1640, 32 to 120°F (0 to 49°C) Steel with paint finish or AES 1640 (not included) DC SOURCES (includes FACP) S T O R AG E T E M P E R AT U R E FI NI S H CO L O R 24V DC Regulated Power Supply 14 to 140°F (-10 to 60°C) Red with Subscriber Rechargeable Battery R EL AT I V E H U M ID I T Y V I SUA L IN D I C AT O R S 1.9 A max current 0 to 93%, non-condensing Front panel LCD (2 x 20 alphanumeric character BA C K U P BAT T E R Y R E C HAR G E C APAB I L I T Y backlit display) 10-12 Ah, UL recognized lead acid Will charge 12V battery size Power and Trouble LEDs gel cell, size based on subscriber from 10-12 Ah (ALM, Trouble, Tx, Rx, WA) configuration Contact Us For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. www.aes-corp.com AES Corporation | 285 Newbury Street | Peabody, MA 01960 United States © Copyright 2018 AES Corporation and AES-IntelliNet® are registered trademarks of AES Corporation 7707_03222018_F METAL PROTECTION STI METAL PROTECTIVE CABINETS STI-EM151804 STI-EM111504 STI-EM121204 KEY FEATURES General Information · Can be used in all wiring applications as a junction, splice or power supply cabinet. Design · Cost effective, low maintenance and compact design. · Includes a document holder, and allows attachment for a pen and key. STI-EM07123.5 STI-EM111103 STI-EM08073.5 · Continuous piano type hinge. Construction · Heavy-duty industrial control panel enclosures are constructed with a powder coated metal to help protect against corrosion. · Metal thickness meets or exceeds Type 1 requirements. Installation · Enclosures mount to the wall enabling units to be protected in EM1212DOC Custom Printing EM1212DOC-BK their designated location. · Back design helps accommodate uneven walls or mounting surface. · Top, side and bottom knockouts See reverse for are 1/2” and 3/4”. PRODUCT OVERVIEW details Options These metal industrial control panel enclosures for electrical and electronic equipment · Thumb or key lock (option sold (up to 1000V) provide a line of defense against hazardous parts and provide a degree separately). of protection to enclosed equipment. Constructed for indoor use, enclosures mount to · Backplate (sold separately) may be mounted into cabinet. the wall enabling electronics, control panels and more to be secured in their designated · Custom printing on enclosures is location. Multiple size options available to help guard against accidental or intentional available. Contact customer service vandalism. for details. · UL, cUL Listed, Type 1 (see Metal enclosures have a durable finish to help protect against corrosion. approvals). For more information, call 248-673-9898 or visit www.sti-global.com. STI Metal Protective Cabinets Dimensions and Technical Information MODELS AVAILABLE APPROVALS STI-EM07123.5 Metal Protective Cabinet 18 gauge · UL, cUL Listed, Type 1 STI-EM08073.5 Metal Protective Cabinet 18 gauge STI-EM111103 Metal Protective Cabinet 18 gauge STI-EM111504 Metal Protective Cabinet 18 gauge STI-EM121204 Metal Protective Cabinet 18 gauge STI-EM151804 Metal Protective Cabinet 17 gauge EM1212DOC Red Metal Cabinet 18 gauge EM1212DOC-BK Black Metal Cabinet 18 gauge Many polycarbonate cabinets also available. Model Height Width Depth STI-EM07123.5 12.20” (310mm) 7.73” (196mm) 3.84” (98mm) STI-EM08073.5 8.40” (213mm) 7.66” (195mm) 3.80” (97mm) STI-EM111103 11.20” (284mm) 11.28” (286mm) 3.30” (84mm) STI-EM111504 15.20” (386mm) 11.28” (286mm) 4.30” (109mm) STI-EM121204 12.20” (310mm) 12.7” (323mm) 4.30” (109mm) STI-EM151804 18.20” (462mm) 15.28” (388mm) 4.30” (109mm) EM1212DOC 12.20” (310mm) 12.7” (323mm) 4.30” (109mm) ACCESSORIES FOR EM MODELS KL544 Key lock (includes 2 keys) TL644 Thumb lock STI-MBP0506 14 gauge backplate for STI-EM07123.5 and STI-EM08073.5* STI-MBP1010 14 gauge backplate for STI-EM111103 and STI-EM121204 STI-MBP0913 14 gauge backplate for STI-EM111504 STI-MBP1316 14 gauge backplate for STI-EM151804 KIT-H18019 Standoff Kit for MBPs, qty. 6 KIT-H18086 Keys (2) for KL544 *Includes a top or bottom plate mount option 2306 Airport Road2306 Airport Roadinfo@sti-usa.com Tel: 248-673-9898Taylor House Unit 49G Pipers Roadinfo@sti-emea.com Unit 7A Lockheed AvenueTel: 44 (0) 1527 520 999 Waterford, MIWaterford, Michiganwww.sti-global.com Fax: 248-673-124634 Sherwood Rd., Bromsgrove,Park Farm Industrial Estatewww.sti-global.com Airport Business ParkFax: 44 (0) 1527 501 999 48327, USA 48327, USATel:248-673-9898 Toll-free: 800-888-4784Worcs., B60 3DR, England Redditch, WorcestershireTel: +44 (0) 1527 520 999 Waterford X91 HWF2 IrelandFree: 0800 085 1678 (UK) info@sti-usa.com B98 OHU England www.sti-europe.com www.sti-usa.com © 2007-2025 Safety Technology International Subject to change without notice. 02/25 Permit #: 6646 Permit Date: 07/25/25 Permit Type: FIRE ALARM Project Name: Seattle Galvanizing Applicant Name: B+H Fire and Security Applicant Address: PO Box 3711 Applicant, City, State, Zip: Arlington, Wa, 98223 Contact: Hailey Brossard Phone: 3603227634 Email: hailey@bnhfire.com Scope of Work: Design build fire alarm installation for new small parts galvanizing operations Valuation: 10700.00 Square Feet: 36824 Number of Stories: 1 Construction Type: VB Occupancy Group: H-4; Hazardous Health ID Code: CIC Permit Issued: 08/12/2025 Permit Expires: 02/11/2026 Form Permit Type: FIRE ALARM Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel # Address Legal Description Owner Name Owner Phone Zoning SEC 22 TWP 31 RGE 05 RT-1C) S 400 FT OF NE1/4 NE1/4 LY E OF NP R/W 399 Other EXC CO RDS ALSO LESS MINA PROPERTIES 31052200102000 18520 67TH AVE NE Miscellaneous R/W TO CITY OF ARL VII LLC Manufacturing NEC PER SWD REC AFN 200201100393 AND CORR AFN 200202080086 Contractors Contractor Primary Contact Phone Address Contractor Type License License # B & H FIRE AND ELECTRICAL JEFF BROSSARD 425-244-1445 PO BOX 3711 COA 603 612 112 SECURITY LLC CONTRACTOR B & H FIRE AND ELECTRICAL LABOR & JEFF BROSSARD 425-244-1445 PO BOX 3711 BHFIRHF842KW SECURITY LLC CONTRACTOR INDUSTRIES Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status FA00. FIRE ALARM 11/17/2025 Fire Alarm Final 11/20/2025 11/20/2025 FIRE Approved FINAL Plan Reviews Date Review Type Description Assigned To Review Status Note all device locations are subject to change after Approved with 07/25/2025 FIRE ALARM BUILDING equipment in place for visual compliance Conditions 07/25/2025 FIRE ALARM FAS Approved FIRE Approved Fees Fee Description Notes Amount Fire System Plan Review Table 4-2 $189.68 Credit Card Service $5.69 Processing/Technology $25.00 FACP / Transmitter - New $200.00 Credit Card Service $6.75 Total $427.12 Attached Letters Date Letter Description 08/12/2025 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 07/28/2025 Jeff Brossard 238444438 Hannah Hardwick $5.69 XBP Conf: 07/28/2025 $189.68 238444438 08/12/2025 Jeff Brossard 239861342 Hannah Hardwick $6.75 XBP Conf: 08/12/2025 $225.00 239861342 Outstanding Balance $0.00 Uploaded Files Date File Name 08/12/2025 27778568-2025_BLD6646_Issued Permit.pdf 08/12/2025 27767173-20250725_BLD6646_Approved Plans.pdf 07/25/2025 27517602-20250725_BLD6646_Plans.pdf 07/25/2025 27517603-20250725_BLD6646_Load Calcs.pdf 07/25/2025 27517604-20250725_BLD6646_Specs Sheets.pdf 07/25/2025 27517605-20250725_BLD6646_App.pdf 425-244-1445 P.O. BOX 3711ARLINGTON, WA 98223LIC. BHFIRHF842KWPH: DESIGNER: JEFF BROSSARD NICET LEVEL 3 ID # 148093 LICENSE: BROSSJB951L7 REFERENCE: 2021 IFC AND 2019 NFPA 72 EXIT EXIT EXIT EXIT EXIT EXIT EXIT MONORAIL 18520 67TH AVE. NE SEATTLE GALVANIZINGARLINGTON SPIN LINEARLINGTON, WASHINGTON 98223 MONORAIL ISSUES REV DATE DESCRIPTION TITLE: FIRE ALARM PLAN MAIN FLOOR FIRE ALARM PLAN - MAIN FLOOR 1 SCALE: 1/16"=1'-0" DATE: JULY 13, 2025 PROJECT NO.: 25-020 SHEET: FA-1 Original Size: 24"x36" 425-244-1445 P.O. BOX 3711ARLINGTON, WA 98223LIC. BHFIRHF842KWPH: DESIGNER: JEFF BROSSARD NICET LEVEL 3 ID # 148093 LICENSE: BROSSJB951L7 REFERENCE: 2021 IFC AND 2019 NFPA 72 EXIT EXIT EXIT EXIT 18520 67TH AVE. NE EXIT EXIT EXIT SEATTLE GALVANIZINGARLINGTON SPIN LINEARLINGTON, WASHINGTON 98223 ISSUES REV DATE DESCRIPTION FIRE ALARM PLAN - ENLARGED MAIN FLOOR FIRE ALARM PLAN - SECOND FLOOR FIRE ALARM PLAN - THIRD FLOOR 1 2 3 SCALE: 1/8"=1'-0" SCALE: 1/8"=1'-0" SCALE: 1/8"=1'-0" TITLE: ENLARGED FIRE ALARM PLANS DATE: JULY 13, 2025 PROJECT NO.: 25-020 SHEET: FA-2 Original Size: 24"x36" 425-244-1445 P.O. BOX 3711ARLINGTON, WA 98223LIC. BHFIRHF842KWPH: EQUIPMENT LEGEND DESIGNER: JEFF BROSSARD NICET LEVEL 3 ID # 148093 LICENSE: BROSSJB951L7 REFERENCE: 2021 IFC AND 2019 NFPA 72 FIRE ALARM ONE-LINE RISER DIAGRAM SCALE: NONE WIRE LEGEND 18520 67TH AVE. NE SEQUENCE OF OPERATIONS DESIGNED AUDIBILITY LEVEL PER OCCUPANCY CLASSIFICATION SEATTLE GALVANIZINGARLINGTON SPIN LINE ARLINGTON, WASHINGTON 98223 GENERAL NOTES: ISSUES ANNUNCIATE SOUNDER ATFACP ANNUNCIATE SOUNDER ATREMOTE ANNUNCIATORTRIGGER BUILDINGAUDIBLE/VISUAL APPLIANCESWATERFLOW ALARM SIGNALTO CENTRAL STATIONALARM SIGNAL TO CENTRALSTATIONTROUBLE SIGNAL TOCENTRAL STATIONSUPERVISORY SIGNAL TOCENTRAL STATION REV DATE DESCRIPTION WATERFLOW DEVICE X X X X TAMPER DEVICE X X X BUILDING PULL STATION X X X X BUILDING SMOKE DETECTOR X X X X TITLE: AC POWER LOSS X X X FIRE ALARM LOW BATTERY X X X LEGENDS, NOTES AND RISER DIAGRAM DATE: JULY 13, 2025 PROJECT NO.: 25-020 SHEET: FA-3 Original Size: 24"x36"