Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3624 177th Pl Ne_BLD6480_2025
Residential Electric Water Professional Prestige ProTerra Hybrid Electric Heat Pump Water Heaters Professional Prestige® ProTerra® Hybrid Electric Heat Pump is the most efficient water heater available Efficiency Operation Modes • Up to 4.07 UEF reduces operating • Energy Saver cost • Heat Pump • ENERGY STAR® certified • High Demand • Title 24 Compliant (JA13 Ready) • Electric Performance • Vacation/Away: 2-28 days (or placed • Delivers hot water faster than most on hold indefinitely) standard electric water heaters – Plus… 60-87 gallons first-hour delivery, depending on model • Premium grade anode rod extends the life of the tank • Ambient operating range: 37-145° F New! Top Connections is widest in class, offering more heat • Dip tube diffuser reduces sediment and Duct Ready Design pump operation annually; designed to improving efficiency and tank life meet Northern Climate Spec (Tier 4) • 3/4" NPT water inlet and outlet; • Quiet Operation 3/4" condensate drain connections Easy Installation • Incoloy stainless steel resistor elements • Universal top and side water • Dry-fire protection connections • Easy access, top mounted washable • Quick access to electrical junction box air filter • Duct ready design • 2" Non-CFC foam insulation • Easily replaces a standard electric • Enhanced flow brass drain valve water heater • Temperature and pressure relief valve Integration installed Professional Prestige • Electronic control for easy temperature • Design certified to NSF/ANSI 372 ProTerra Hybrid Electric adjustment and mode management (Lead Content) • Audible alarm for service alerts Heat Pump Warranty • Built-in Wi-Fi powered by EcoNet®* 40, 50, 65 and 80-Gallon • 10-Year limited tank and parts and free mobile app gives users Capacities warranty control over water heater, allowing for 208-240 Volt / 1 PH customizable temperature, vacation See Residential Warranty Certificate for complete information 30 and 15 Amp settings, energy savings and system monitoring at home or away Units meet or exceed ANSI requirements and have Electric been tested according to D.O.E. procedures. Units • Demand Response Ready with built-in meet or exceed the energy efficiency requirements EcoPort™ (CTA-2045 Port) of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria. • Easily add leak detection and prevention with the leak LEED Points = 3 sensor and shutoff valve kit (part# SP21265A sold separately) *Wi-Fi broadband internet connection required. See specifications chart on next page. INTEGRATATED HOME COMFORED HOME COMFORT T 07/24 WP FORM NO. HP-400-NO SO Professional Prestige® ProTerra Hybrid Electric Heat Pump Specifications SHIPPING DESCRIPTION ENERGY INFO FEATURES WEIGHTS UEF NOMINAL RATED ELECTRIC UNIFORM FIRST HR. RECOVERY TOTAL UNIT APPROX. GALLON GALLON MODEL MODEL BREAKER ENERGY FACTOR COMPRESSOR RATING IN G.P.H ELEMENT UNIT MAX WT. SHIP WT. CAPACITY CAPACITY NUMBER VARIANT SIZE (UEF) BTU/H G.P.H. 90° F RISE WATTAGE WATTAGE AMPS (LBS) (LBS.) ProTerra 30 Amp 40 36 PROPH40 T2 RH400-30 702303 30 3.83 4,200 60 27 4,500 5,000 21 166 184 50 45 PROPH50 T2 RH400-30 702300 30 3.88 4,200 67 27 4,500 5,000 21 185 203 65 59 PROPH65 T2 RH400-30 702302 30 4.05 4,200 76.6 27 4,500 5,000 21 245 289 80 72 PROPH80 T2 RH400-30 702344 30 4.07 4,200 87 27 4,500 5,000 21 261 306 ProTerra 15 Amp 40 36 PROPH40 T2 RH400-15 702293 15 3.45 4,200 46 16 2,250 2,750 12 166 184 50 45 PROPH50 T2 RH400-15 702297 15 3.75 4,200 52 16 2,250 2,750 12 185 203 65 59 PROPH65 T2 RH400-15 702292 15 3.55 4,200 54 16 2,250 2,750 12 245 289 80 72 PROPH80 T2 RH400-15 702295 15 3.70 4,200 67 16 2,250 2,750 12 261 306 Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements. All units have integrated Wi-Fi control board. I 2†Clearance Needed for T&P Release F J G B H K A C E D DESCRIPTION DIMENSIONS (SHOWN IN INCHES) NOMINAL GALLON MODEL CAPACITY NUMBER A B C D E F G H I J K 40 PROPH40 62-5/16 20-1/4 47 3-5/8 39-5/8 25-3/8 20-1/2 78-7/8 20-1/4 21-3/4 64-15/16 50 PROPH50 61-3/4 22-1/4 47 3-5/8 39-5/8 27-3/8 22-1/2 78-5/8 22-1/4 21-3/4 64-3/8 65 PROPH65 64-3/16 24-1/4 49 3-7/8 42-3/8 29-1/2 24-5/8 81-1/8 24-1/4 25-13/16 66-13/16 80 PROPH80 74-3/16 24-1/4 59 3-7/8 42-3/8 29-1/2 24-5/8 91 24-1/4 25-11/16 76-13/16 2 Hybrid Electric Heat Pump Water Heater Installation Guidelines to Provide Optimal Efficiency Heater: Not Ducted Heater: Not Ducted Room size: Smaller than 700 ft3 (e.g. 7' x 10' x 10'). Room size: Larger than 700 ft3 (e.g. 7' x 10' x 10'). Requirements: Full louvered door OR two louvers Requirements: No additional ventilation needed. top and bottom. See below. Heater: Not ducted Room: Small Closet Requirements: * Air gap under door equal to 18 in2 (0.75†clearance). * Louver must be located the same height on door as the air exhaust on heater. * Heater air exhaust must be positioned towards louver within one foot of door. Air exhaust .75†24†12†Max Door Heater: Ducted with inlet OR outlet duct Heater: Ducted with inlet AND outlet duct Room size: Any size room Requirements: Air gap under door equal to 18 in2 Room size: Any size room (0.75†clearance) Requirements: No additional ventilation needed. .75†24†NOTE: Heat pump water heater will operate in rooms less than 700 ft3 down to 450 ft3 but at reduced energy efficiency and reduced performance output. Reduced energy efficiency and performance has not been evaluated by Rheem Manufacturing and not recommended for optimal performance of the unit. When unit is operated in a small enclosure, a door or wall with a minimum of 2.3 sq ft of louvers is recommended to provide proper air changes for unit function. 3 Residential Electric Water Professional Prestige ProTerra Hybrid Electric Heat Pump Water Heaters Hybrid Electric Heat Pump Accessories List PART NUMBER DESCRIPTION USE FOR AP19134 Leak Sensor Automatic detection of internal and external leaks AS50618A Shutoff Valve Automatic shutoff of water supply to unit SP20882 Earthquake Isolation Kit Installations in seismic regions SP20883 Vibration Isolation Kit Installation on non-concrete floors SP20884 8" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 8" diameter SP20885 7" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 7" diameter SP20886 6" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 6" diameter SP20887 5" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 5" diameter SP20888 8" Collar for Flex Venting Exhaust only to the outside ducting configuration (no inlet duct) SP20889 25' Flexible 8" Diameter Duct Kit For up to 25' of ducting SP20890 8" Rigid Elbow Duct Kit Installation in tight places where space needs to be minimized UPGRADE KIT Add leak detector, shutoff valve and S.O.V. extension harness for top SP21265A Kit - Automatic Shutoff Valve Assembly connection setup Leak Sensor Shutoff Valve Earthquake Isolation Kit Vibration Isolation Kit 8" Diameter UL Certified 7" Diameter UL Certified 6" Diameter UL Certified 5" Diameter UL Certified Termination Kit Termination Kit Termination Kit Termination Kit 8" Collar for Flex Venting 25' Flexible 8" Diameter Duct Kit 8" Rigid Elbow Duct Kit UPGRADE KIT (for ProTerra models without LeakGuard only) – Add leak detector and shutoff valve to protect from water damage Leak Sensor & Shutoff Valve Kit In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100 Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Roswell, Georgia 30076 • www.rheem.com Brampton, Ontario L6Y 0P5 • www.rheem.ca 4 INTEGRATATED HOME COMFORED HOME COMFORT T 07/24 WP FORM NO. HP-400-NO SO Permit #: 6480 Permit Date: 05/06/25 Permit Type: RESIDENTIAL PLUMBING Project Name: Alan Adams Applicant Name: Washington Water Heaters Applicant Address: 6622 232nd AVE E Applicant, City, State, Zip: Buckley Contact: Steve Hyde Phone: 4258834871 Email: wawahvac@gmail.com Scope of Work: Remove and replace electric water heater Valuation: 7500.00 Square Feet: 1353 Number of Stories: 1 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 05/06/2025 Permit Expires: 11/03/2025 Form Permit Type: RESIDENTIAL PLUMBING Status: EXPIRED Assigned To: Kristin Foster Property Parcel # Address Legal Description Owner Name Owner Phone Zoning PHYLLIS A 100 SINGLE 00598900003400 3624 177TH PL NE ANNEN/ADAMS FAMILY ALAN/BRIANA RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License # WASHINGTON 6622 232nd Ave CONSTRUCTION 425-883-4871 L&I WAWATWH780BO HEATING & AIR E CONTRACTOR WASHINGTON 6622 232nd Ave CONSTRUCTION 425-883-4871 COA 604846080 HEATING & AIR E CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status Unable to R14. PLUMBING on site at 3:30 no entry crazy 05/20/2025 05/21/2025 05/21/2025 BUILDING Inspect - No FINAL dog only one home Access C00. Final inspection is complete 11/07/2025 BUILDING Approved CONSULTATION and approved. Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Plumbing Base Permit Fee $25.00 Water Heater (Tank) $25.00 Credit Card Service $4.50 Total $154.50 Attached Letters Date Letter Description 05/06/2025 Building Permit 05/05/2025 Web Form- Residential Plumbing Application Payments Date Paid By Description Payment Type Accepted By Amount 05/05/2025 Washington Water Heaters 230565807 $4.50 XBP Conf: 05/05/2025 $150.00 230565807 Outstanding Balance $0.00 Notes Date Note Created By: 10/24/2025 Expiration notice sent LaNay Hendrick 09/26/2025 Expiration notice sent LaNay Hendrick Uploaded Files Date File Name 05/06/2025 25790187-20250506_BLD6480_IssuedPermit.pdf 05/06/2025 25788900-20250506_BLD6480_Specs.pdf 05/06/2025 25788899-20250506_BLD6480_Application.pdf