Loading...
HomeMy WebLinkAbout6108 188th St NE_BLD3452_2025 COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 The following minimum information is required for your Commercial/Multi-Family Building Permit Application. Mark each box to designate that the information has been provided. Please submit this checklist as part of your submittal documents. Incomplete applications will delay the review. One (1) City of Arlington Commercial/Multi-Family Permit Application (One (1) permit application per building or structure is required) One (1) City of Arlington Commercial/Multi-Family Submittal Requirements Form Two (2) Architectural Drawings Two (2) Structural Drawings Two (2) Structural Calculations One (1) Project Specification Manuals (if applicable) One (1) NREC Code Compliance Forms One (1) Special Inspection Requirements Forms One (1) Occupant’s Statement of Intended Use Form Drawings shall be BOUND SEPARATELY BY TYPE, architectural, structural and landscape, and then ROLLED TOGETHER IN COMPLETE SETS> An intake appointment is required for all new Commercial or Multi-Family Building Permit Applications. To schedule an appointment please contact the City of Arlington Permit Center at (360) 403 3551 or by email to ced@arlingtonwa.gov. I acknowledge that all items designated above are included as part of this application. REV 2019 Page 1 of 9 COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 A. FEES DUE AT TIME OF PERMIT ISSUANCE B. CODES The City of Arlington currently enforces the following: International Codes 1. 2015 International Building Code (IBC) 2. 2015 International Residential Code (IRC) 3. 2015 International Mechanical Code (IMC) 4. 2015 International Fuel Gas Code (IFGC) 5. 2015 International Fire Code (IFC) 6. 2015 Uniform Plumbing Code (UPC) 7. 2015 International Property Maintenance Code (IPMC) 8. 2015 International Existing Property Code (IEBC) 9. 2015 Washington State Energy Code (WESC) 10. 2017 Accessible & Usable Buildings and Facilities (ICC/A117.1) Washington State Amendments 1. WAC 51-50 Washington State Building Code 2. WAC 51-51 Washington State Residential Code 3. WAC 51-52 Washington State Mechanical Code 4. WAC 51-54 Washington State Fire Code 5. WAC 51-56 & 51-57 Washington State Plumbing Code and Standards 6. WAC 51-11 Washington State Energy Code 7. WAC 296-46B Electrical Safety Standards, Administration, and Installation C. CITY OF ARLINGTON DESIGN REQUIREMENTS Design Wind Speed: 85 miles per hour (Exposure C) Ground Snow Load: 25 pounds per square foot Seismic Zone: D2 Rainfall: 2 inches per hour for roof drainage design. Frost Line Depth: 18 inches Soil Bearing Capacity: 1,500 psf unless a Geo-Technical Report is provided. (IBC Table 1804.2 & IRC R401.4.1) D. PLANS AND DRAWINGS Submit two (2) complete sets of drawings and plans. Drawings and plans must be submitted on minimum 18” X 24”, or maximum 30” X 42” paper. All sheets are to be the same size and sequentially labeled. Plans are required to be clearly legible, with scaled dimensions, in indelible ink, blue line, or other professional media. Plans will not be accepted that are marked preliminary or not for construction, that have red lines, cut and paste details or those that have been altered after the design professional has signed the plans. Please Note: A separate submittal of plans is required for each building or structure. REV 2019 Page 2 of 9 COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 DETAILED SUBMITTAL REQUIREMENTS Mark each box to designate that the information has been provided. Please submit this checklist as part of your submittal documents A. SITE PLAN – REQUIRED WITH ALL SUBMITTALS (May be included as part of the Architectural Drawing cover Sheet) 1. Drawing shall be prepared at scale not to exceed 1” = 20 feet. 2. Show building outline and all exterior improvements. 3. Provide property legal description and show property lines. 4. Provide dimensions from the property lines to a minimum of two building corners (or two identifiable locations for irregular plan shapes). 5. Show building setbacks, easements and street access locations. 6. Indicate North direction. 7. Indicate finish floor elevation for the first level. 8. Provide topographical map of the existing grades and the proposed finished grades with maximum five feet elevation contour lines. 9. Show the location of all existing underground utilities, including water, sewer, gas and electrical. 10. Flood hazard areas, floodways, and design flood elevations as applicable. B. ARCHITECTURAL DRAWINGS 1. Cover Sheet a) Building Information 1. Specify model code information. 2. Construction Type. 3. Number of stories and total height in feet. 4. Building square footage (per floor and total) 5. IBC Occupancy Type (show all types by floor and total). 6. Mixed-use ratio (if applicable) 7. Occupant load calculation (show by occupancy type and total) 8. List work to be performed under this permit b) Design Team Information 1. Design Professional in Responsible Charge 2. Architects 3. Structural Engineers 4. Owner 5. Developer 6. Any other Design Team Members 2. Floor Plan a) Plan view 1/8” minimum scale. Details a minimum ¼-inch scale. b) Plans must show the entire tenant space. c) Specify the use of each room/area. d) Provide an occupant load calculation on the floor plan. (on every floor, in all rooms and spaces) e) Show ALL exits on the plans; include new, existing or eliminated. f) Show Barrier-Free information on the drawings. g) Show the location of all permanent rooms, walls and shafts. h) Note the uses in the adjacent tenant spaces, if applicable. i) Provide a door and door hardware schedule. REV 2019 Page 3 of 9 COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 j) Show the location of all new walls, doors, windows, etc. k) Provide details and assembly numbers for any fire resistive assemblies. l) Indicate on the plans all rated walls, doors, windows and penetrations. m) Provide a legend that distinguishes existing walls, walls to be removed and new walls. 3. Reflected Ceiling Plan a) Plan view 1/8” minimum scale. Details a minimum ¼-inch scale. b) Provide ceiling construction details. c) Provide suspended ceiling details complying with IBC 803.9.1.1. Show seismic bracing details. d) Show the location of all emergency lighting and exit signage. e) Detail the seismic bracing of the fixtures. f) Include a lighting fixture schedule. 4. Framing Plan a) Specify the size, spacing, span and wood species or metal gage for all stud walls. b) Indicate all wall, beam and floor connections. c) Detail the seismic bracing for all walls. d) Include a stair section showing rise, run, landings, headroom, handrail and guardrail dimensions. 5. Storage Racks (if applicable) a) Structural calculations are required for seismic bracing of storage racks eight feet or greater in height. b) Eight feet or less, show a positive connection to floor or walls. NOTE: High pile storage shall meet the requirements of current International Building and Fire Codes. C. SPECIAL INSPECTION 1. Where special inspection is required by IBC 1704, the registered design professional in responsible charge shall prepare a special inspection program that will be submitted to the City of Arlington and approved prior to issuance of the building permit to comply with IBC 106.1. D. WASHINGTON STATE ENERGY CODE 1. One (1) completed Washington State Non-Residential Energy Code Envelope Summary forms. E. OCCUPANT’S STATEMENT OF INTENDED USE 1. The Occupant’s Statement of Intended Use form shall be completely filled out and may require the submittal of a Hazardous Materials inventory Statement (HMIS). Contact the Arlington REV 2019 Page 4 of 9 COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 The building permit does not include any mechanical, electrical, plumbing or fire sprinkler/alarm work. These permits are issued separately. Mechanical, electrical, plumbing, or fire sprinkler/alarm permits require a separate permit application and may also require separate plan review. Please note that any tenant improvement work in a space that involves food handling or preparation requires Snohomish County Health District approval before the permit can be issued. You must provide the Permit Center a copy of the approval letter or the approved plans. Contact the Snohomish County Health District at (425) 339-5250 with any questions or for more information. An intake appointment is required for all large Tenant Improvement Building Permit Applications. To determine if your project requires an intake appointment, to schedule an appointment or to ensure that you have the most current information, please contact the City of Arlington Permit Center at (360) 403-3551 or by email to ced@arlingtonwa.gov. Incomplete applications will not be accepted. I acknowledge that all items designated as submittal requirements must accompany my Building Permit Application to be considered a complete submittal. REV 2019 Page 5 of 9 COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION TO BE USED FOR NEW COMMERCIAL STRUCTURES AND RESIDENTIAL DWELLINGS NOT REGULATED UNDER THE IRC. THIS APPLICATION MUST BE ACCOMPANIED BY A COMMERCIAL APPLICATION SUBMITTAL CHECKLIST AND AN OCCUPANT’S STATEMENT OF INTENDED USE. Bowman Dispensers T.I. $71,295.00 Name of Project: Valuation: Project Address: 6108 188th Street NE , Suite B400, Arlington, Washington Parcel ID #: 31052200102700,31052200102500Legal Description See attached Owner: PSMARTCAP 188th St. Development QOZB, LLC hone Number: 425-422-3484 Address: 8201 164th Ave. NW, Suite 110 City: Redmond State: WA Zip Code: 98052 Engineer: N/A Phone Number: Cell Phone: E-mail: Address: City: State: Zip Code: General Contractor: Smartcap Construction, LLC Phone Number: Cell Phone: 206-290-4478 E-mail: tyson@smartcapconstruction.com Address: 8201 164th Ave. NE, Suite 110 City: Redmond State: WA Zip Code: 98052 Contractor’s License Number: SMARTCL1810NR Expiration: 08/19/2021 Contact Person: PTyson Goodwin hone Number: Cell Phone: 206-290-4478 E-mail: tyson@smartcapconstruction.com Address: 8201 164th Ave. NE, Suite 100 City: Redmond State: WA Zip Code: 98052 Proposed Scope of Work: NEW OPEN OFFICE, RECEPTION, RESTROOMS AND WAREHOUSE STORAGE SPACE FOR BOWMAN DISPENSERS. REV 2019 Page 6 of 9 COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 Project Name/Tenant __________Bowman Dispensers____________________________________________________________ Site Address_______________6108 188th Street NE, Arlington______________________________ Bldg/Unit/Suite ____________________ B400 IBC Construction Type ______III-B _________________________ IBC Occupancy Type ____________________ B and S-1 Description of Use _______________Office and warehouse storage_________________________________________________________ Building Square Footage ________49,507.5 s.f. footprint__________________ Number of Stories_________________________ 1 Square Footage Per Floor__________688 s.f. office space, 4,918 s.f. warehouse space._________________________________________________________ Will there be any installation, modification or removal of the following? (Check all that apply) Automatic fire extinguishing systems Compressed gas systems Fire alarm and detection systems Fire pumps Flammable and combustible liquids (tanks, piping etc…) Hazardous materials High piled/rack storage Industrial ovens/furnace Private fire hydrants Spraying or dipping operations Standpipe systems Temporary membrane structure, tents (>200sq ft) or canopies (>400 sq ft) Provide details on any of the above checked items: _______________________________________________________________Modifications to the building fire alarm and fire sprinkler to meet code re_____________ quirements ____________________________________________________________________________ ____________________________________________________________________________ ____________________________________________________________________________ Installation, changes, modifications or removal of any of the above may require additional submittals, information, or permits during the plan review or construction process. Statement of Special Inspection REV 2019 Page 7 of 9 COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 The special inspection functions are considered to be in addition to the normal inspections performed by the City and the contractor is responsible for contacting the City to schedule regular inspections. No concrete shall be poured or other work covered until approved by the City Inspector. Building Division: The Building Division shall review any revisions and addenda. Approved copies will be given to the contractor to maintain as part of the approved plan set. The City Inspector will monitor the special inspection functions for compliance with the agreement and the approved plans. The City Inspector shall be responsible for approving various stages of construction to be covered and work to proceed. Design Professionals: The architect and engineer will clearly indicate on the plans and specifications for the specific types of special inspection required, and shall include a schedule for inspection and testing. The architect and engineer will coordinate their revisions and addenda process in such a way as to insure all required City approvals are obtained, prior to work shown on the revisions being performed. Owner: The project owner, or the architect or engineer acting as the owners agent, shall employ the special inspector or agency. ENFORCEMENT: A failure of the special inspector or firm to perform in keeping the requirements of the IBC, the approved plans and this document may void this agreement and the Building Officials approval of the special inspector. In such case a new special inspector and/or firm would need to be proposed for approval. A failure of the design and/or construction parties to perform in accordance with this agreement may result in a STOP WORK notice being posted on the project, until nonconforming items have been resolved. ACKNOWLEDGEMENTS I have read and agree to comply with the terms and conditions od and agree to comply with th f this agreement. Owner: ________________________________________________________________________________ __ Date: ___________________9/21/2020 I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington. _____________________________________________________________ Applicants Signature _____________________________________Robert Shipley _______________________9/17/2020 Print Applicants Name Date FOR STAFF USE ONLY ____________________ ____________________ ____________________ ____________________ ____________________ Permit # Accepted By Amount Received Receipt # Date Received REV 2019 Page 9of 9 Robert Shipley 12.17.20 Lighting Summary LTG-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Info Project Title: Bowman Dispensers at Smartcap 188th, Arlington Date 8/24/2020 Compliance Applicant Information. Provide contact information for individual who can For Building Department Use forms do not respond to inquiries about compliance form information provided. require a Company Name: Smartcap password to use. Company Address: 8201 164th Ave. NE, Suite 110 Instructional and calculating cells Applicant Name: Robert Shipley are write- protected. Applicant Phone: 425-422-3484 Applicant Email: robertsh@smartcapgroup.com Project Description New Building Addition AlterationFALSE No Lighting Scope Include PROJ-SUM form (included in envelope forms workbook) with lighting compliance forms. Interior Lighting System LED and Fluorescent lighting with energy effiicient compliant controls. Description Interior Lighting Plans Included Interior Lighting Power Building Area Method Space-by-space Method Allowance Method Select method used in project. Interior Lighting Controls All C405.2.1 - C405.2.8 Lighting Controls C405.2 Exception 5 Luminaire Level FALSE Lighting Controls (LLLC) Additional Efficiency Package Option C406.4 Enhanced Digital Lighting To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with t required controls per C406.4. Dwelling Unit Interior Permanently installed interior lighting fixtures in dwelling units comply with: No Dwelling Units Lighting C405.2 thru C405.5 Commercial Lighting Controls and LPA C406.3 High Efficacy Lighting R404.1 Residential High Efficacy Lighting. Dwelling unit lighting complies with WSEC Residential provisions in lieu of WSEC Commercial provisions. Exterior Lighting System Existing Description Exterior Lighting Plans Included Building Additions Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project Refer to Section C502.2.6 for additional requirements. Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance Addition is combined with existing: For interior lighting projects, include new + existing-to-remain interior lighting fixture wattage in Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. For exterior lighting projects, include new + existing-to-remain exterior lighting fixture wattage in Proposed Tradable and Proposed Non-Tradable Lighting Wattage tables in LTG-EXT form. Lighting Summary, cont. LTG-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Bowman Dispensers at Smartcap 188th, Arlington Date 8/24/2020 Change of Space Use Existing interior lighting systems in areas under-going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting Lighting Alterations 50% or more of existing are replaced Select all Lighting Power and Lighting Control elements that apply to the scope Less than 50% of existing are replaced of the retrofit project. If project includes a combination of spaces where less than Lamp and/or ballast replacement only 50% of the existing fixtures are replaced – existing total wattage not increased in some spaces, and 50% or more of the 50% or more replaced - Total lighting power of new + existing-to-remain fixtures shall comply with fixtures are replaced in others, then total LPA per Sections C405.4.2 and C405.5.2. Include new + existing-to-remain fixtures in provide separate lighting power Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. compliance forms for the two retrofit conditions. Spaces undergoing the same Less than 50% replaced - Total lighting power of new + existing-to-remain fixtures shall not exceed type of retrofit may be combined into one the total lighting power prior to alteration. Include new + existing-to-remain fixtures in the Proposed lighting power compliance form. Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. 50% threshold applies to number of luminaires for interior spaces and parking garages, and total Refer to Section C503.6 for additional installed wattage for exterior luminaires. requirements. Lighting Controls Interior lighting Parking garage Exterior lighting All alteration lighting controls shall be New wiring installed to serve added commissioned per C408.3. fixtures and/or fixtures relocated to new circuit(s) New or moved lighting panel Interior space is reconfigured - luminaires unchanged or relocated New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. No changes are being made to the interior or exterior lighting New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. systems and existing space uses and configuration are not Reconfigured interior space - Provide all required lighting controls that apply to a new interior changed. space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured Interior Lighting - Space-By-Space Method LTG-INT-SPACE 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Bowman Dispensers at Smartcap 188th, Arlington Date 8/24/2020 Calculation For Building Department Use New Construction Addition - Addition Area NOTE 9 Spaces where < 50% of Spaces where ≥ 50% of Spaces where the Use LPA Standard Additional Efficiency Package Option Calculation C406.3 Reduced Interior Lighting To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Type Refer to C406.3 for additional requirements. User Note Maximum Allowed Lighting Wattage NOTE 1 Location (plan #, Ceiling Gross Interior Allowed Watts Allowed NOTE 2 2 2 2 room #) Space Type Height Area in ft Watts per ft (watts/ft x area) Office Office: Open plan 9 450 0.780 351 Restroom Restroom: all other 9.5 131 0.780 102 Lobby Lobby: all other 9 107 0.720 77 Warehouse Warehouse: Medium/bulky palletized items 24 4918 0.497 2443 Total Area 5606 Retail Display Allowance from LTG-INT-DISPLAY Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 8 Allowed Watts 2974 Proposed Lighting Wattage NOTE 3 Location (plan #, Number of Watts/ Watts room #) Fixture Description NOTE 4, 5, 6 Fixtures Fixture NOTE 7 Proposed Office 2'x4' lay in LED troffer 5 22 110 Restrooms 2' fluorescent light fixture 232 64 Warehouse LED High Bay light fixture 8 232 1856 R/R & Lobby LED recessed can light 7 21 147 Proposed Retail Display Lighting from LTG-INT-DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 2177 Interior Lighting Power Allowance COMPLIES WITH C406.3 Note 1 - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Enter all proposed lobby art/exhibit display fixtures in LTG-INT-DISPLAY form only. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types and gross interior areas. SITE Tenant Improvement for BOWMAN DISPENSERS Developed by Smartcap 188th Street Industrial Park, Building B Arlington, Washington LANCE MUELLER & ASSOCIATES A R C H I T E C T S A I A 130 LAKESIDE SUITE 250 SEATTLE, WA 98122 (206) 325-2553 TA1.0 Tenant Improvement for BOWMAN DISPENSERS Developed by Smartcap 188th Street Industrial Park, Building B Arlington, Washington LANCE MUELLER & ASSOCIATES A R C H I T E C T S A I A 130 LAKESIDE SUITE 250 SEATTLE, WA 98122 (206) 325-2553 TA2.0 Tenant Improvement for BOWMAN DISPENSERS Developed by Smartcap 188th Street Industrial Park, Building B Arlington, Washington LANCE MUELLER & ASSOCIATES A R C H I T E C T S A I A 130 LAKESIDE SUITE 250 SEATTLE, WA 98122 (206) 325-2553 TA3.0 Tenant Improvement for BOWMAN DISPENSERS Developed by Smartcap 188th Street Industrial Park, Building B Arlington, Washington LANCE MUELLER & ASSOCIATES A R C H I T E C T S A I A 130 LAKESIDE SUITE 250 SEATTLE, WA 98122 (206) 325-2553 TA4.0 625 Fourth Avenue PH 425 827-3324 Suite 202 FAX 425 827-6252 Kirkland, WA 98033 natalie@franklineng.com September 9, 2020 ENVELOPE SUMMARY RE: Bowman Dispensers – Office 188th Street Industrial Park, Building A Arlington, WA Conversion of existing semi-heated warehouse to conditioned Office space. Project complies with 2015 WSEC, Commercial Provisions, using the Component Performance approach and is within 110% of the Target UA per exception listed under section C505.1 Roof: R-38 minimum rigid insulation above roof deck. U=0.027, default Table A102.2.6(1) Wall (Metal, Opaque, Warehouse, Floor to Roof): 6” metal studs, 24" oc with R-21 batt insulation, plus R-7.5 continuous rigid, U=0.054, default Table A103.3.6.1(1) Wall (Metal, Opaque, Floor to Roof, Demising Wall): 6” metal studs, 16" oc with R-21 batt insulation, U=0.106, default Table A103.3.6.1(1) Wall (Mass, Opaque, Exterior, Floor to 9’-0” AFF): Concrete, min 6” thick, air gap, 3-1/2” metal studs, 24" oc with R-15 batt insulation, U=0.102, default Table A103.3.6.1(1) per footnote (c) to Table A103.3.7.1(4) Wall (Mass, Opaque, Exterior, 9’-0” AFF to Roof): Concrete, min. 6” thick, with continuous R-25 batt insulation on stickpins, U=0.038, default Table A103.3.7.1(4) Floor Over: Metal joist with R-21 batt insulation, U=0.11, default Table A105.1(3) Slab on Grade: No Insulation, F=0.73, default Table A106.1 Wholesmart - Office Envelope Summary September 9, 2020 Page 2 Doors (Swinging, Opaque): Insulated metal, U=0.37, default Table A107.1(1) Vertical Glazing (Fixed): NFRC certified assembly, U=0.38, SHGC=0.40 Vertical Glazing (Entrances): NFRC certified assembly, U=0.60, SHGC=0.40 Please note that these values are minimum insulation requirements for code compliance. Higher insulation values may be installed. SHGC = Solar Heat Gain Coefficient Project Summary, pg 1 PROJ-SUM 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Oct 2017 General Info Project Title: Bowman Dispensers Date 9/9/2020 PROJ-SUM form Project Street Address: 188th Street Industrial Park, Building A For Building Department Use shall be provided as Project City, County, Zip: Arlington, Wa a cover sheet for all compliance form Project Owner or Rep: submittals. Project Title shall match Jurisdiction: project plans title block. Project Description New Construction and Additions Select all that apply to the New Building Building Addition scope of project. Select Addition + Existing or Existing Building Retrofit Alteration + Existing if the existing building will be Alteration Change of Occupancy Change in Space Conditioning combined with the addition or alteration to demonstrate compliance per Section Historic Building C502.1 or C503.1. Building Elements Scope - Select all that apply All Building Envelope Mechanical Systems Service Hot Water Systems Lighting Systems Electrical Systems All Commercial Group R - R2, R3, & R4 Mixed Use over 3 stories and all R1 Mixed Use - Building is greater than three stories above grade and it has both Commercial and Group R Occupancy Type occupancies. Mixed Occupancy - Building is three stories or less above grade and it has both Commercial and Group R2, R3 or R4 occupancies. Select All Commercial to document compliance for the commercial areas of the building. The residential spaces shall comply with the WSEC Residential Provisions. Select all that apply to the scope of project Fully Conditioned Semi-heated2 Refrigerated Spaces (Warehouse and/or Walk-in1) Low Energy Space Category3 Space Conditioning Categories Eligible Low Energy Spaces Unconditioned Low energy heating/cooling capacity Wireless service Greenhouse4 Equipment building equipment shelter Floors Above Floor Area and Building Gross Conditioned Floor Area Project Gross Conditioned Floor Area Grade Stories 1 620 620 Compliance Method 1 - General Compliance Method 2 - Total Building Performance Compliance Method 1 - Projects shall demonstrate compliance with all applicable mandatory and prescriptive requirements of this code. Refer to C401.2, Item 1 for more information. Compliance forms to General Compliance include with a Prescriptive submittal: All applicable ENV, LTG, and MECH. Path Compliance Method 2 - Projects complying via total building performance (TBP) shall include a summary of results from a whole building energy model per Section C407 and shall demonstrate compliance with all applicable mandatory provisions in this Code. Refer to Section C401.2, Item 2 for more information. Compliance forms to include with a TBP submittal: PROJ-SUM, ENV-CHK, LTG-EXT, LTG-CHK, and all MECH forms except MECH-ECONO and MECH-VENT (pending). Note 1 - Refrigerated Spaces - They shall comply with the envelope and refrigeration equipment requirements in Section C410. Warehouse coolers and freezers shall also comply with the envelope requirementsin C402. C410 takes precedent for overlapping requirements. Note 2 - Semi-heated Spaces - If heated with equipment other than electric resistance may take an exemption for wall insulation.All other envelope assemblies shall comply with the thermal envelope provisions. Note 3 - Exemptions For Low Energy Spaces - Low Energy spaces are exempt from all provisions in WSEC Section C402 Building Envelope, however all other applicable provisions in the Code do apply including lighting, mechanical, service water heating, etc. Note 4 - Eligible Space Conditioning For Low Energy Greenhouses - Greenhouses are defined as spaces that maintain a specialized sunlit environment that is used exclusively for cultivation, protection and maintenance of plants. Cooling with outside air and/or evaporative cooling, and any form of heating equipment, are allowed under the Low Energy Greenhouse category. Greenhouses withcooling equipment that requires a condensing unit are NOT eligible. Project Summary, pg 2 PROJ-SUM 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Oct 2017 General Info Project Title: Bowman Dispensers Date 9/9/2020 C406 Additional Building level efficiency options: Current Scope Previous Projects Efficiency Package C406.8 Enhanced envelope performance Options Summary C406.9 Reduced air infiltration A minimum of two Options are C406.5 On-site renewable energy required for new construction, and change in space Building area level efficiency options conditioning or occupancy projects. C406.2 More efficient HVAC equipment Select all Options included in the current project scope. C406.6 Dedicated outside air systems (DOAS) Also select Options complied with under previous projects C406.7 Reduced energy use in service water heating (shell and core, other tenant spaces in building, etc) C406.3 Reduced lighting power Buildings with multiple tenant spaces may comply with C406.4 Enhanced digital lighting controls different options (mix & match). C406 Comments: Options are required for all space conditioning categories. Include discipline specific information for C406 options in ENV-SUM, LTG-SUM and Refer to SBCC website for official interpretations regarding C406 provisions. Envelope Summary ENV-SUM 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Oct 2017 Project Info Project Title: Bowman Dispensers Date 09/09/2020 Company Name: Lance Mueller & Associates For Building Department Use Applicant Info. Provide contact Company Address: 130 Lakeside Ave Ste 250 - Seattle, WA 98122 information for individual who can Applicant Name: Harold Christensen respond to inquiries about information Applicant Phone: 206-325-2553 provided. Applicant Email: haroldc@lmueller.com Project Description New Building Addition Alteration No Envelope Scope Envelope Project Scope All Commercial Group R - Commercial Mixed Use - Commercial + Group R Select all that apply. Semi-heated Refrigerated Cooler Refrigerated Freezer Equipment Building Envelope Description Provide brief description of the project and relevant supporting documentation. If project includes multiple Target Insulation Allowance areas, and/or is demonstrating compliance as an Addition + Existing, Alteration + Existing, or Addition + Alteration + Existing project, provide a brief summary of the approach to whole building compliance. Air Barrier Testing Air barrier testing per Section C402.5.1.2 included in project scope Air barrier testing is required for all new construction projects. Testing criteria is 0.40 Additional Efficiency Package Option - C406.9 Reduced Air Infiltration cfm/ft2 under test pressure of 0.3 inch w.g. To comply with C406.9, demonstrate that Testing not required. Explanation: measured air leakage of building envelope Compliance Documentation Scope and Method Scope of This Calculation New Building Addition Alteration No Envelope Scope Target Insulation Allowance Fully Conditioned - Commercial, Group R, Mixed Use Sets the title and calculations in the compliance forms. Selection required Semi-heated Refrigerated Cooler Refrigerated Freezer to enable forms. If project includes more than one Target Insulation Allowance area, and/or if project includes addition and alteration areas complying independently, for each area complete an ENV-SUM form Rows 16-46 and either an ENV-PRESCRIPTIVE form, or ENV-UA + ENV-SHGC forms if demonstrating compliance via component performance. Envelope Compliance Path Prescriptive Component Performance Selection required to enable forms. Component Performance Change of Occupancy (C503.2) / Conditioning (C505) - 10% higher UA allowed Calculation Adjustments Additional Efficiency Package Option - C406.8 Enhanced Envelope - 15% lower UA required Additions Addition stand alone Addition + Existing Addition stand alone - Complete Vertical Fenestration and Skylight Area Calculation. Enter total existing-to-remain wall, roof, vertical fenestration and skylight areas as EXISTING. Enter total addition envelope assembly areas as NEW. If resulting total building WWR exceeds 30% and/or SSR exceeds 5%, refer to C502.2.1 and C502.2.2 for prescriptive compliance alternatives. If complying via component performance, complete ENV-UA per instructions for addition stand alone projects. Addition + existing - Complete ENV-UA per instructions for addtion + existing projects. Alterations - Replacement windows only, or resulting Total building WWR increased by alteration total building WWR ≤ original WWR Fenestration and Skylight Replacement skylights only, or resulting Total building SRR increased by alteration total building SRR ≤ original SRR WWR and SRR not increased - Vertical Fenestration and Skylight Area Calculation not required. WWR and/or SRR increased - Complete Vertical Fenestration and Skylight Area Calculation. Enter total existing-to-remain wall, roof, vertical fenestration and skylight areas as EXISTING. Enter total altered envelope assembly areas as NEW. If resulting total building WWR exceeds 30% and/or SSR exceeds 5%, refer to C503.3.2 and C503.3.3 for prescriptive compliance alternatives. If complying via component performance, complete ENV-UA per instructions for alteration + existing projects. Envelope Summary, pg. 2 ENV-SUM 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Oct 2017 Project Title: Bowman Dispensers Date 09/09/2020 Vertical Fenestration and Total Vertical NET Exterior Fenestration Area Above Grade Total Skylight Area NET Exterior Roof Skylight Area Calculation (rough opening) Wall Area (rough opening) Area Prescriptive Path - Enter envelope sf values New 240 3,229 0 676 directly into this section of ENV-SUM for vertical fenestration, skylights, net walls and Existing 0 0 0 0 roof. For Additions and Alterations, refer to these sections in ENV-SUM for further instructions. Total 240 3,229 0 676 Component Performance - When this Envelope Compliance Path is selected, write- protection of this section is enabled. Enter Vertical Skylight-to-Roof envelope sf values for all assemblies into the Fenestration-to- 6.9% ENV-UA form. Envelope information from Wall Ratio (WWR) Ratio (SRR) ENV-UA will auto-fill into this section of ENV- Vertical Fenestration Area Compliance VERTICAL FENESTRATION AREA COMPLIES WITH MAXIMUM ALLOWANCE Skylight Area Compliance NO SKYLIGHT PROPOSED. COMPILIES WITH MAXIMUM ALLOWANCE. Vertical Fenestration High performance fenestration U-factors and SHGC per C402.4.1.3 Alternates Dedicated outdoor air system per C402.4.1.4 and C403.6 Show locations of qualifying daylight zone In buildings ≥ 3 stories, 25% or more of NET floor area is in DLZ per C402.4.1.1 (DLZ) areas and ft2 on project plans. In buildings < 3 stories, 50% or more of CONDITIONED floor area is within DLZ per C402.4.1.1 For Daylight Zone Area Calculations - Daylight Zone Calculations a) Sidelight areas include primary + secondary daylight zone areas. Daylight Zone Fenestration Alternate Sidelight Daylight Toplight Daylight Percent Daylight b) Include overlapping toplight and sidelight Not Selected. No Calculations Required Zone Area Zone Area Zone Area daylight zone areas under Toplight. c) Net floor area definition in Chapter 2. Spaces in Single Story List all enclosed spaces that exceed 2,500 ft2, have ceiling height greater than 15 ft, and are space Building Requiring Skylights types required to comply with this provision. Indicate aperture with "AP" prefix (AP 1.1%) In these spaces a minimum of 50% of the Space Space Area (ft2) DLZ Area (ft2) SRR or Aperture Exception floor area shall be within a skylight daylight zone (DLZ). Refer to C402.4.2 for requirements. SRR = Skylight to roof ratio Envelope Exemptions Low Energy and Semi-heated Low energy spaces per C402.1.1 Item 1 are exempt from the thermal envelope provisions. Semi- heated spaces heated by systems other than electric resistance are exempt from wall insulation Spaces provision only per C402.1.1.1. Complete Low Energy and Semi-Heated Spaces table in MECH-SUM to verify eligibility based on installed peak heating and cooling capacity per sf. Equipment Buildings Wall Insulation Roof Insulation Overall Average R-Value R-Value U-Factor Equipment buildings are exempt from the Equipment Building Envelope thermal envelope provisions per C402.1.2. The following shall be met to be eligible: Electronic equipment power (watts/sf) building size ≤ 500 sf, average wall/roof U- Heating system output capacity (Btu/hr) factor ≤ U-0.20, electronic equipment load ≥ 7 watts/sf, heating system output capacity ≤ Cooling capacity (Yes/No) 17,000 btu/h. Cooling system capacity not limited. Component Performance Path, pg. 1 ENV-UA 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Oct 2017 Project Title: Bowman Dispensers Date 09/09/2020 Target Insulation Allowance For Building Department Use Fully Conditioned Space - Commercial, Group R, Mixed Use Calculation Adjustments Proposed UA is allowed to be 10% higher than Target UA Fenestration Area as % gross above-grade wall area 6.9% Max. Target: 30.0% Skylight Area as % gross roof area 0.0% Max. Target: 5.0% Vertical Fenestration Alternates: None Selected on ENV-SUM For Stand-alone Projects13,14 Vertical Fenestration Net Wall User Note Existing-to-remain Areas Skylights Net Roof Building Component Proposed UA Target UA Cavity+CI Plan/Detail # U-factor Source & Table # 2 U-factor x Area (A) = UA (U x A) U-factor x Area (A) = UA (U x A) R=38 R-38 Rigid Above Deck 0.027 676 18.3 0.027 676 18.3 R= Above Deck Insulation U-0.027 Deck R= R= 0.031 R= Metal Building U-0.031 Mtl BldR= RoofsR= 0.027 R= Joist/single rafter U-0.027 Joist/RftrR= R= 0.021 R= Single raft, attic, other U-0.021 Attic/OthR= R=28 6" mtl std 24" oc R-21 + R-7.5 cont 0.054 1624 87.7 0.055 2523 138.8 R=21 6" mtl std 16" oc R-21 0.106 899 95.3 Steel/metal frame U-0.055 Steel R= 4,6 R= 0.052 R= Metal Building U-0.052 Mtl Bld.R= R= 0.054 Above Grade - R= Wood Frame, other U-0.054 Wood/OthR= 3 R=15 3.5" mtl std 24" oc R-15 0.102 165 16.8 0.104 685 71.2 R=25 R-25 Stickpin 0.038 520 19.8 Mass Wall U-0.104 Mass R= Opaque Walls 5 R= 0.200 R= Mass Transfer Deck U-0.20 TransferR= 7 R= 0.078 R= Group R Mass Wall U-0.078 Mass Group RR= 4,6 R= 0.104 R= Assumed to be Mass Wall U-0.104 Comm R= R= 0.078 R= Assumed to be Mass Wall U-0.078 Below Grade WallsGroup RR= R= 0.031 R= Mass Floor U-0.031 Mass R= FloorsR=21 Metal Joist R-21 0.110 56 6.2 0.029 56 1.6 R= Joist/Framing U-0.029 FramedR= Area1 UA Area1 UA Page 1 Subtotal 3940 244 3940 230 Component Performance Compliance (UA) UA COMPLIES W/ EXISTING SPACE EXEMPTION Component Performance Path, pg. 2 ENV-UA 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Oct 2017 Project Title: Bowman Dispensers Date 09/09/2020 Fenestration Area For Building Department Use as % gross above-grade wall area 6.9% Max. Target: 30.0% Skylight Area as % gross roof area 0.0% Max. Target: 5.0% Building Component Proposed UA Target UA Ins. R Plan/Detail # F-factor Source & Table # 8 F-factor x Perimeter = FP(F x P) F-factor x Perimeter = UA (U x A) R= Uninsulated 0.730 119 86.9 0.540 119 64.3 R= Slab-On-Grade F-0.54 -gradeUnheatedR= -on R= 0.550 R= Heated Slab-On-Grade F-0.55 Slab HeatedR= Schedule ID U-factor Source9,10 U-factor x Area (A) = UA (U x A) U-factor x Area (A) = UA (U x A) Man Door 0.37 21 7.8 0.370 21 7.8 Opaque Swing Doors U-0.37 6,9 Swinging 0.340 Doors Opaque rollup & sliding U-0.34 Other 0.30 Non-Metal Frame U-0.30 -Metal Non NFRC 0.38 219 83.2 0.38 219 83.2 6,10 Metal Frame, Fixed U-0.38 Metal, fixed 0.40 Metal Frame, Operable U-0.40 Vertical FenestrationMetal, op. NFRC 0.60 21 12.6 0.60 21 12.6 Metal Entrance Door U-0.60 Mtl entrance 10 0.50 All types U-0.50 SkylightsAll Types Refrigerated Space Freezer Floors Proposed UA Target UA CI Plan/Detail # U-factor Source & Table # 2 U-factor x Area (A) = UA (U x A) U-factor x Area (A) = UA (U x A) R= R= Freezer Floor Floor Freezer R= Area1 UA Area1 UA Page 2 Subtotal 380 190 380 168 Page 1 Subtotal 3940 244 3940 230 TO COMPLY - The Proposed Total UA shall not exceed the Target Total UA. Project Total 4320 434 4320 398 Component Performance Compliance (UA) UA COMPLIES W/ EXISTING SPACE EXEMPTION Refrigerated Space Windows In Doors 11, 12 Cooler / Double Pane Triple Pane Inert Gas Heat Reflective Plan/Detail # Description Freezer Glass Glass Filled Treated Glass In Door Glazing in Doors Reach in Note 1 - If vertical fenestration or skylight area exceeds maximum allowed per C402.4.1, then Target Area Adjustment of all applicableenvelope Vertical Fenestration Target Area Adjustment Calculations Project Title: Bowman Dispensers Date 09/09/2020 If vertical fenestration area exceeds maximum allowed per Section C402.4.1, then Target Area Adjustment of all applicable envelope elements is required. This worksheet automatically calculates these adjustments and updates target areas in the ENV-UA and ENV-SHGC worksheets. Information shown in this worksheet is for reference only and is write-protected. Submit this Target Area Adjustment form with ENV-UA and ENV-SHGC forms. VF = Vertical fenestration NW = Net above grade wall (excludes fenestration and doors.) DR = Opaque doors Gross Exterior Above-Grade Wall Area= VF + NW + DR AG = Above-grade Proposed Areas Vertical Fenestration Net Above Grade Wall Opaque Door Project Areas -> VF= 240.0 NW= 3208.0 DR= 21.0 Existing Non-project Areas -> VF= NW= Gross Exterior Max Vert. Fen. % Maximum Target AG Wall Area (C402.3.1) Vert. Fen. Area 3469.0 x 30.0%  100 = 1040.7 Total Vertical Delta Vertical Excess Vertical 0 Fenestration Maximum Target Fenestration Fenestration 240.0 - 1040.7 = -800.7  greater = -800.7 Multiplier applied to all Project Vertical Excess Vertical Target Vertical Total Vertical Proposed Vertical Fenestration Areas to Fenestration Fenestration Fenestration Fenestration Target VF Multiplier calculate Target Vertical 240.0 - = 240.0  240.0 = 1.00 Fenestration Area Net AG Wall Area Excess Fenestration Target Net Wall Area Net Wall Target Net Wall Mult. Multiplier applied to all 3208.0 + = 3208.0  3208.0 = 1.00 Proposed Opaque Above- Grade Wall Areas to calculate Target Above- Target Areas - UA Grade Wall Area Commercial Vertical Fenestration Proposed Area Target VF Mult. Target Area Non-metal frame x = Metal frame, fixed 219.0 x 1.00 = 219.0 Metal frame, operable x = Metal frame, entrance door 21.0 x 1.00 = 21.0 Target areas in shaded Above-grade Wall Proposed Area Target Net Wall Mult. Target Area boxes are applied to target areas on ENV-UA Steel Frame 2523.0 x 1.00 = 2523.0 Metal Building x = Wood / Other frame x = Mass 685.0 x 1.00 = 685.0 Mass Transfer Deck x = Group R Mass x = Sum of target above-grade Sum of ProposedSum of Proposed 3448.0 Sum of Target 3448.0 wall and vertical fenestration areas are Target Areas - SHGC x A calculated to equal the sum of proposed Non-North Vertical Fenestration Proposed Area Target VF Mult. Target Area PF < 0.2 x = 0.2 ≤ PF < 0.5 x = PF ≥ 0.5 x = SHGC target areas in shaded boxes are applied North Vertical Fenestration to target areas on ENV- PF < 0.2 x = SHGC 0.2 ≤ PF < 0.5 x = PF ≥ 0.5 x = Skylight Target Area Adjustment Calculations Project Title: Bowman Dispensers Date 09/09/2020 If skylight area exceeds maximum allowed per Section C402.4.1, then Target Area Adjustment of all applicable envelope elements is required. This worksheet automatically calculates these adjustments and updates target areas in the ENV-UA and ENV-SHGC worksheets. Information shown in this worksheet is for reference only and is write-protected. Submit this Target Area Adjustment form with ENV-UA and ENV-SHGC forms. SKY= Skylight NR - Net roof (excludes skylight) Gross Exterior Roof Area = SKY + NR Proposed Areas Skylight Net Opaque Roof Project Areas -> SKY= NR= 676.0 Existing Non-project Areas -> SKY= NR= Gross Exterior Max Skylight % Maximum Skylight Roof Area (C402.3.1) Fenestration Area 676.0 x 5.0%  100 = 33.8 Total Skylight Area Maximum Target Delta Skylight Area 0 Excess Skylight - 33.8 = -33.8  greater = -33.8 Project Multiplier applied to all Skylight Area Excess Skylight Target Skylight Area Total Skylight Area Target SKY Multiplier Proposed Skylight Areas - =  = to calculate Target Skylight Area Net Project Roof Area Excess Skylight Target Net Roof Area Net Roof Target Net Roof Mult. Multiplier applied to all Proposed Opaque Roof 676.0 + = 676.0  676.0 = 1.00 Areas to calculate Target Roof Area Target Areas - UA and SHGC x A Skylight Proposed Area Target SKY Mult. Target Area All x = Roof Proposed Area Target Net Roof Mult. Target Area Target areas in shaded Insulation Above Deck 676.0 x 1.00 = 676.0 boxes are applied to target Metal Building x areas on ENV-UA Joist / Single Rafter x = Attic / All Others x = Sum of target roof and Sum of Proposed 676.0 Sum of Target 676.0 skylight areas are calculated to equal the sum of proposed