HomeMy WebLinkAbout123 E Burke Ave_BLD810_2025 BUILDING INSPECTION REPORT - Fire Alarm Permit No. 810 Address: 123 E Burke Avenue Contractor: Froula Alarm Systems, Inc. Owner: SHOPPING CENTER PROP OF ARLINGTON LLC Date: 11/4/2015 ~ APPROVAL □ PARTIAL APPROVAL □ CORRECTION □ OTHER INSPECTION: FIRE ALARM: 181 LOCKS: □ FACP ACCESS: 181 ANNUNICATION: 181 ELEVATOR RECALL: □ DAMPERS: 181 PULL STATIONS: 181 MAGNETIC HOLDS: □ SMOKE DETECTORS: ~ CENTRAL STATION: 181 HEAT DETECTORS: 181 FIRE FINAL: 181 AUDIONISUALS: 181 Date: 11/4/2015 Inspector: Kevin Olander CITY OF ARLINGTON 238 N. OL \'.MPIC A VE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: 123 E Burke Avenue Permit#: 810 Parcel#: 00461803000100 Valuation: 9100.00 OWNER APPLICANT CONTRACTOR Name: SHOPPING CENTER PROP OF Name: Froula Alarm Systems, Inc. Name: FROULA ALARM SYSTEMS ARLINGTON LLC Address: PO BOX 271 Address:861 Industry Drive Address: 861 INDUSTRY DRIVE City, State Zip: BURLINGTON, WA 98233 City, State Zip: Tukwila, WA 98188 City, State Zip:TUKWILA, WA 98188-3411 Phone: Phone: 206-575-1962 Phone: 206-575-1962 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City, State, Zip: City, State, Zip: Phone: Phone: UC#: EXP: LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2012 STORIES: 1 CONST. TYPE: DWELLING UNITS: 0 OCCGROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRCI 10. CONDITIONS Adhere to approved plan. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/13/2015 Fire Alarm Fee $226.95 10/13/2015 Fire Review Fee $100.00 Total Due: $326.95 Total Payment: $0.00 Balance Due: $326.95 CALL FOR INSPECTIONS BUILDING (360) 403-3417 When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon Permit Information Date 10/8/2015 Permit Number 810 Project Name Grocery Outlet Applicant Name Froula Alarm Systems, Inc. Applicant Address 861 Industry Drive City, State, Zip Tukwila, WA 98188 Contact JD Dunlap Phone 206-575-1962 Email jd@froulaalarms.com Permit Type Fire Alarm Site Address 123 E Burke Avenue Valuation 9100.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use Grocery Store Assigned To Launa Peterson Property Information Owner Information Parcels: 00461803000100 SHOPPING CENTER PROP OF ARLINGTON LLC SHOPPING CENTER PROP OF ARLINGTON LLC PO BOX 271 123 E BURKE AVENUE BURLINGTON, WA 98233 Contractors Primary Contractor Contractor Name Phone Email License License# Contact Type FROULA ALARM Labor & 'd@froulaalarms com FR OU LAS 122DS SYSTEMS --- 111111 Industries Uploaded Files - Date File ~ • Etl r") 'l FIRE ALARM PERMIT APPLICATION Department of Community & Economic Development City of Arlington •18204 59th Ave NE• WA 98223 • Phone (360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY THREE (3) SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO, INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS, (POINT TO POINT WIRING), AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) D New Fire Alarm Cl] Fire Alarm Alteration/ Addition 146 - East Haller Avenue Project Address:-------------------- Parcel ID#: 13 320 9100.00 Number of Zones/Panels: Building Area (Sq Ft): --' ---- Valuation: Owner: Grocery Outlet Phone Number: _1 _1 ----------- Address: _1 _1 City: _11 State: 11 Zip Code: _1 _1 _ Contact Person:JD Dunlap Froula Alarm Systems Inc Phone Number: -206--6-61--60-54 ------- Cell Phone: 206-661-6054 E-mail: jd@froulaalarms.com Address: 861 Industry Drive City: Tukwila State: __WA __ Zip Code: _9_8_18_8 _ Contractor: Froula Alarm Systems Inc Phone Number: _20_6_-_5_7_5_-1_9_6_2 _ 861 - Industry Drive c·ity·. Tukwila WA 98188 Address: -------State: --- Zip Code:-------- . FROULA122DS . . 3-10-16 Contractor's License Number:---------------- Expiration: -------------- Electrical Contractor: Froula Alarm SyStems Inc Phone Number: _2o_5_-_5_7_5_-1_9_6_2 _ 861 - Industry Drive Address: City: Tukwila State: WA Zip Code: _9_8_18_8 _ . FROULA122DS . . 3-10-16 Contractor's License Number: Expiration: -------------- I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be accordance with the laws, rules and regulations of the State of Washington. The applicant will be responsible for providing a method of safely accessing roof for inspection. A final inspection and approval shall be obtained when the re-roofing is complete. I ;)'~i~~?:~~::~:tapl 1010712015 Applicants Signature Date Jeffrey M Dunlap Print Applicants Name FOR STAFF USE ONLY oct O 7 20\5 Permit# Amount Received Receipt# Date Received WEB Form - 130 Page 1 of 1 7/10CJY -►~ ~ COLEMAN CABLE Toll-Free (800) 323-9355 Wiring The World Fax: (847) 689-1192 PRODUCT DATA SHEET PART NUMBER: 98420 DESCRIPTION: 14/2 SOLID FPLR RED CABLE CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424, NEC Articles 760. APPLICATION: Power Limited Fire Alarm Cable For Riser Applications Construction Parameters: Cable Cross-Section Conductor 14 AWG Bare Copper Stranding Solid .\ Insulation Material Foam Polypropylene (: ! J Insulation Thickness 0.010" Norn. Insulated Conductor Diameter 0.084" Norn. Number of Conductors 2 Lay Length 3.00" Norn. Jacket Material PVC Jacket Thickness 0.017" Norn. Overall Cable Diameter 0.202" Norn. Approximate Cable Weight 35.1 Lbs/1 M' Norn. Flame Rating UL 1666 Riser Flame Test Electrical Properties: Temperature Rating -20°C to 60°C Operating Voltage 300 V RMS Max. Capacitance Between Conductors @ 1 KHz 25 pF/ft Norn. Capacitance Between Conductors to Shield @ 1 KHz Inductance 0.07 uH/ft Norn. DC Resistance per Conductor @ 20°c 2.54 Ohms/1M' Norn. Insulation Colors Black Red Jacket Color Red (Other colors available for minimum order) Legend (Surface Ink Print) E100315 * 14 AWG 2/C (UL) TYPE FPLR SUN RES On sped al orders, the customer will accept all factory lengths and +/- 1 O percent of total order requested. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of infonnation contained herein or otherwise. This specification is proprietary intelectual property of Coleman Cable. Any information contained herein shall not be disclosed to any party without written consent of Coleman Cable. Customer Name Date Signed _ Customer Approval _ Specification Issue Date: August 13, 2001 1-800-323-9355 (Phone) Designed By: PEP 1-847-689-1192 (Fax) 98420 © 2000 Coleman Cable Systems, Inc. Specification Sheet Sealed Lead-Acid Batteries BSL 1075 (PC1270) Capacity Specifications Technical Specifications Cut-off Voltage 20 Hr Rate (0.36 A) 7.2 Ah Nominal Voltage 12V 1.75 v/c@ 25°C 10 Hr Rate (0.65 A) 6.5 Ah Nominal Capacity 7.2 Ah (20 Hr Rate) 1.70 v/c 5 Hr Rate (1.14 A) 5.7 Ah Dimensions Length: 150 mm 1.55 v/c 1 Hr Rate (4.1 A) 4.1 Ah Width: 64.5 mm Bloc Per Cell Height: 95 mm Charge Voltage (constant) Float 13.5-13.8 2.25-2.30 Total Height/Terminal: 101 mm Cycle 14.4-14.7 2.40-2.45 Weight Approx 2.75 Kg Discharge Current Amps 80 Unit: mm (±0.50) {5 seconds maximum) Discharge Current Amps 50 ~IDI (maximum continuous) Max. Charge Current 2.16 A Approx Final Charge 0.014 (14 mA) Current {2.25 vie Float) Approx Final Charge 0.07 (70 mA) Current {2.45 vie Cycle) Terminal Type Type A / (G optional) Self Discharge 9 months @ 21 °C Case Material ABS - Gray* or Black Due lo changes in the manufacturing proces.ses, specificalions may change without notice. •Gray option is flame Retardant ABS. Actual Wattage / Ampere Capacity at Various Discharge Times (Volt per Cell @ 25 °C) ~e me 5 Min. 10 min. 15 min. 30 min. 45 min. 60 min. 1.75v/c w 45.4 30.77 23.28 12.9 10.31 8.07 25°C A 25.94 17.58 13.3 7.37 5.89 4.61 1.67 v/c w 47.76 31.4 23.9 13.09 10.04 8.07 25°C A 28.6 18.8 14.31 7.84 6.01 4.83 1.60 v/c w 49.28 31.52 24.0 13.3 9.3 7.79 25°C A 30.8 19.7 15.0 8.31 5.81 4.87 interstatebatteries.com © Interstate Battery System of America, Inc. 02/03 ws FROULA ALAJIM S'IS'l'.i!MS, In". Froula Alarm Systems, Inc. 861 Industry Drive ♦ Tukwila WA 98188-3411 Phone: 206-575-1962 ♦ Fax: 206-575-8 I 68 October 7, 2015 Fire Alarm System Submittals For Grocery Outlet Store #1151 146 East Haller Avenue Arlington, Washington 98223 CITY O ARLINGTON Received 8UILDING OEPARTMENT OCT O 7 2015 APPROVED OFFICE COPY om {P,-"ij'"~. av, /4Q ... CHANtH:SNffltORIZED UNLSSS APPROVED Y THI BUILDINO INSPECTOR FROULA ALAIIIM $V:$Til!lil3, In<=. Froula Alarm Systems, Inc. 861 Industry Drive ♦ Tukwila WA 98188-3411 Phone: 206-575-1962 ♦ Fax: 206-575-8168 Grocery Outlet October 7, 2015 Table of Contents Fire Alarm System Manufacturer Model No. Description Farenhyt IFP-100 Addressable Fire Alarm Control Panel - EXISTING System Sensor SR Multi-Candela Wall Mount Strobe System Sensor P2R Multi-Candela Wall Mount Hom/Strobe System Sensor PC2R Multi-Candela Ceiling Mount Hom/Strobe System Sensor PC2RH Multi-High-Candela Ceiling Mount Hom/Strobe Coleman 98420 14-2 FPLR Wire Interstate BSL1075 12V 7.2AH Battery - EXISTING SILENT Farenhyt KNIGHT :~) by Honeywell Intelligent Fire Alarm Control Panel Intelligent Fire Alarm Control Panel Agency Listings IFP-100 MEA IFP-100 is an intelligent analog/addressable fire control panel. The basic IFP-100 system has a single SLC loop and four notification @ 429-92-E Vol. XIV appliance circuits that can be programmed for notification outputs or auxiliary power. IFP-100 also has a built-in dual line digital fire communicator, Form C trouble relay, and two programmable Form C relays. The firmware has powerful features, such as detector sensitivity, day/night thresholds, drift compensation and pre-trouble maintenance alert. IFP-100 supports a variety of other devices that can be added to the system such as RA-100 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module, and SD or IDP Protocol devices. Features • Built-in support for up to127 SD devices or 99 IDP detectors and 99 IDP modules • Uses standard wire-no shielded or twisted pair required • Built-in digital communicator for remote reporting of system activity and system programming using either SIA or CID formats. • Central station reporting by point or by zone • Jumpstart® auto-programming Supports Class B (Style 4) and Class A (Style 6 or Style 7) configuration for SLC IFP-100 Distributed, intelligent power • 6 amp power supply and maximum charging • Built-in synchronization for AMSECO, Gentex®, Faraday, System capacity of 35 amp hours (An additional cabinet Sensor®, and Wheelock® appliances enclosure is required for batteries in excess of • Sensor sensitivity settings and day/night sensitivity setting 18 amp hours) Automatic drift compensation • Integrated dead front panel protects operator from exposure to electrical components Notification circuits configurable as 2 Class A (Style Z), 4 Class B (Style Y), or auxiliary power for resettable, constant, or door holder • The FACP enclosure features a Plexiglass® power viewing window to protect annunciator • Built-in annunciator with a backlit BO-character LCD display Programmable to automatically display oldest event first or display tally of system events • RS-485 bus provides communication to system accessories • Acknowledge function allows operator to keep • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC track of event status Tvwoo e built-in Form C programmable relays rated at 2.5 amps at 27.4 Installation • SLC device locator can be used to locate a single or multiple The IFP-100 can be surface or flush mounted. devices on a SLC loop Compatibility • System automatically performs detector sensitivity test The IFP-100 SLC supports multiple device types of • 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable patterns the same protocol: • Built-in RS-232 and USB interface for programming • SD • Upload or download programming, event history, or detector status • IDP onsite or from a remote location using a PC and 5650/5651 Silent You cannot mix SD and IDP devices on a FACP. Knight Software Suite (SKSS) See SD Devices data sheet (PN 350360) and IDP • Improvements in SKSS deliver five times faster upload/downloads Device Protocol Devices data sheet (PN 350361 ). • Non volatile event history stores up to 1000 events • 125 Software zones and 125 output groups Programmable date setting for Daylight Saving Time P/N 350388 Rev K © 2013 Honeywell International Inc. Specifications Physical Approved Releasing Solenoids Flush Mount Dimensions: 14.5"W x 24.75"H x 3.5"0 Manufacturer Part Number Rating (36.8 vV x 62.9 H x 8.73 D cm) Asco T8210A107 24 VDC, 3A Overall Dimensions: 16"W x 26.4"H x 4.65"0 Asco 8210G207 24 voe, 3A (40.6 W x 67 H x 11.8 D cm) Weight: 28 lbs. (12.8 kg) Ordering Information Color: Red IFP-100 Intelligent Fire Alarm Control Panel. Environmental SBUS Accessories Operating Temperature: 32°F - 120°F (0°C - 49°C) RA-100 Remote Annunciator. Same operation and Humidity: 10% - 93% non-condensing similar appearance to FACP annunciator. RA-1000R Remote Annunciator. Four line LCD Electrical annunciator with 20 characters per line. Primary AC: 120 VRMS @ 50/60 Hz, 2.5A Red. Total Accessory Load: 6A@ 27.4 VDC power-limited RA-1000 Remote Annunciator. Four line LCD Standby Current: 170 mA annunciator with 20 characters per line. Cray. Alarm Current: 325 mA RPS-1000 Intelligent Power Module. Battery Charging Capacity: 7 to 35 AH 5496 Intelligent Power Module. Battery Size: 18 AH max. allowed in control panel cabinet. 5824 Serial/Parallel Printer Interface Module. Larger capacity batteries can be housed in RBB accessory cabinet. 5880 LED 1/0 Module. 5865-3 & 5865-4 LED Fire Annunciators. Notification Appliance Circuits 5883 Relay Interface Board. Four circuits that can be programmed individually as: Notification Circuits: 3A per circuit@ 27.4 VDC, power-limited SD and IDP Devices Auxiliary Power Circuits: 3A per circuit@ 27.4 VDC, See the specification sheets listed below for a complete listing power-limited of the SD and IDP devices. Indicator Lights 350360 SD Devices Specification Sheet. Alarm (Red): Flashes when in alarm; solid when alarm silenced 350361 IDP Devices Specification Sheet. Supervisory (Yellow): Flashes when a supervisory condition Miscellaneous Accessories exists; solid when supervisory silenced 5650/5651 Silent Knight Software Suite. Provides Trouble (Yellow): Flashes when a trouble condition exists; solid programming, upload/download, and event when trouble silenced reporting. Silenced (Yellow): Solid when an alarm, trouble or supervisory 5670 Silent Knight Software Suite. Provides condition has been silenced but not yet cleared facility monitoring. Power (Green): Flashes for AC failure; solid when power RBB Remote Battery Box Accessory Cabinet. systems are normal Use if backup batteries are too large to fit into FACP cabinet. Dimensions: Telephone 16" W x 1 O" H x 6" D Requirements: FCC Part 15 & Part 68 approved (406 mm W x 254 mm H x 152 mm D) Jack: RJ31 X (two required) SK-SCK Seismic Compliance Kit Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7165-0559:0142; MEA 429-92-E Vol. XIV; OSHPD (CA) OSP-0065-10 SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications KNIGHT or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472- •i) by Honeywell 1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, please call Made in the U.S.A. 800-446-6444. www.farenhyt.com ~~SYSTEM ~~ SENSOR' - Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance audible visible notification products SPECTWE!rt are rich with features guaranteed to cut installation times A .• ll,;X.6 .. &.ji •. i and maximize profits. Features The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. • Plug-in design with minimal intrusion into the back box With white and red plastic housings, wall and ceiling mounting • Tamper-resistant construction options, and plain and FIRE-printed devices, SpectrAlert Advance • Automatic selection of 12- or 24-volt operation at can meet virtually any application requirement. 15 and 15/75 candela Like the entire SpectrAlert Advance product line, wall-mount horns, • Field-selectable candela settings on wall units: 15, 15/75, strobes, and horn strobes include a variety of features that increase 30, 75, 95,110,115,135,150,177, and 185 their application versatility while simplifying installation. All devices • Horn rated at 88+ dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. • Universal mounting plate for wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage, SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring, so installers can test wiring continuity before the device is installed. • Compatible with MDL3 sync module • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING ® <8> MEA 7125-1653: 186 (indoor strobes) LISTED APPROVED approved 7125-1653: 188 (horn strobes, s,101 l (chimes, horn strobes. horns) 3023572 MEA452-05-E chime strobes) S5512 {strobes) 7135-1653: 189 (horns, chimes) SpectrAlert Advance Specifications Architect/Engineer Specifications - -- -~- - -- - - - - - - -- ~ - -~ --- - - -- - - --- General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 1 ½-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit'" Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177. and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Cumbinalion The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash lube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V ( 12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V ( 12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12to 18AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.TW x 2.5"0 (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.TW x 1.3"0 (142 mm L x 119 mm W x 33 mm D) Wall-Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS) 5.TL x 4.B"W x 0.35"0 (145 mm L x 122 mm W x 9 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 ed. UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15ll5 15 15ll5 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 st Coded Medium 78 78 85 85 90 90 97 98 gt Coded Low 74 75 81 81 88 85 96 92 1Settings 7, 8, and 9 are not available on 2-wire horn strobes. SpectrAlert Advance Dimension_s _ 2.5" c=,,, 4_=.7_ ="=!!!!"5;~=:::::t-. C-1 CJ C-1 C-1 = CJ 5.6" Wall-mount horn strobes SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Wall Strobes (cont.) )' P2R 2-Wire Horn Strobe, Standard cd, Red SRH Strobe, High cd, Red P2R-P 2-Wire Horn Strobe, Standard cd, Red, Plain SRH-P Strobe, High cd, Red, Plain P2R-SP 2-Wire Horn Strobe, Standard cd, Red, "FUEGO" SRH-SP Strobe, High cd, Red, "FUEGO" P2RH 2-Wire Horn Strobe, High cd, Red SW Strobe, Standard cd, White P2RH-P 2-Wire Horn Strobe, High cd, Red, Plain SW-P Strobe, Standard cd, White, Plain P2W 2-Wire Horn Strobe, Standard cd, White SWH Strobe, High cd, White P2W-P 2-Wire Horn Strobe, Standard cd, White, Plain SWH-P Strobe, High cd, White, Plain P2WH 2-Wire Horn Strobe, High cd, White Horns P2WH-P 2-Wire Horn Strobe, High cd, White, Plain HR Horn, Red P4R 4-Wire Horn Strobe, Standard cd, Red HW Horn, White P4R-P 4-Wire Horn Strobe, Standard cd, Red, Plain Accessories P4RH 4-Wire Horn Strobe, High cd, Red TR-HS Trim Ring, Wall, Red P4W 4-Wire Horn Strobe, Standard cd, White SBBR Indoor Surface Mount Back Box, Red Wall Strobes SBBW Indoor Surface Mount Back Box, White ) _s_R S_t_ro_b_e_, S_t_a_nd_a_r_d_c_d_, R_e_d _ SR-P Strobe, Standard cd, Red, Plain SR-SP Strobe, Standard cd, Red, "FUEGO" Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. ~~SYSTEM 3825 Ohio Avenue• St. Charles, IL 60174 ©2014 System Sensor. Phone: 800-SENSOR2 • Fax: 630-377-6495 Product soec' cauc-s sucrect to change <Mlhou: nouce. V1s1t svere-se-so-com www.systemsensor.com for current product information, including the latest version of this data sheet. '--~ SENSOR AV□S10201 • 1/14 ~~SYSTEM C~ SENSOR~ Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications SpectrAlert® Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. SPECT~rt A .• R,.X . .A .. .lll_lt •. i Features The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. • Plug-in design with minimal intrusion into the back box With white and red plastic housings, wall and ceiling mounting • Tamper-resistant construction options, and plain and FIRE-printed devices, SpectrAlert Advance • Automatic selection of 12- or 24-volt operation at 15 and can meet virtually any application requirement. 15/75 candela Like the entire SpectrAlert Advance product line, ceiling-mount • Field-selectable candela settings on ceiling units: 15, 15/75, 30, strobes and horn strobes include a variety of features that increase 75, 95,110,115,135,150,177, and 185 their application versatility while simplifying installation. All devices • Horn rated at 88+ dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. • Universal mounting plate for ceiling units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage, SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring, so installers can test wiring continuity before the device is installed. • Compatible with MDL sync module • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING ® MEA LISTED <8> approved 7125-.653· 186 (indc'Jr strobes) APPROVED 7125-" 653 188 {hn-n strobes. Ss4s0s 11 (chimes. horn strobes. hams) 3023572 MEAL 52-05-E chime strobes) 12 (s-otes) 7135- · 653 189 {ho•ns. C" mes) SpectrAlert Advance Specifications Architect/Engineer Specifications --- - - - -- -- -~-- -------------- - - - -- - - ------ --- General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 1 ½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x I7/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit'" Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 2118-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.S"diameter x 2.5"high (173 mm diameter x 64 mm high) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2) 7.1 "diameter x 2.2"high (180 mm diameter x 57 mm high) Ceiling-Mount Trim Ring Dimensions (sold as a 5 pack) (TRC-HS, 6.9"diameter x 0.35"high (175 mm diameter x 9 mm high) TRCW-HS) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 ed. i\VIJS:'LJ!Jlll UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Hom Strobe, Standard Candela Range (15-115 cd) 8-17.5 Volts 16-33Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Strobe Tones and Sound Output Data Horn Strobe Output (dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 st Coded Medium 78 78 85 85 90 90 97 98 gt Coded Low 75 75 81 81 88 85 96 92 !Settings 7, 8. and 9 are not available on 2-wire horn strobes. /\VDS00!1(J I SpectrAlert Advance Dim~~~i_o_n_s _ 7 7 Ceiling-mount horn strobes Ceiling back box skirt SpectrAlert Advance Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2R* 2-Wire Horn Strobe, Standard cd, Red SCR Strobe, Standard cd, Red ) PC2RH 2-Wire Horn Strobe, High cd, Red SCRH Strobe, High cd, Red PC2W't 2-Wire Horn Strobe, Standard cd, White sew• Strobe, Standard cd, White PC2WH' 2-Wire Horn Strobe, High cd, White SCWH Strobe, High cd, White PC4R 4-Wire Horn Strobe, Standard cd, Red Accessories PC4RH 4-Wire Horn Strobe, High cd, Red BBSC-2 Back Box Skirt, Ceiling, Red PC4W 4-Wire Horn Strobe, Standard cd, White Back Box Skirt, Ceiling, White TRC-HS Trim Ring, Ceiling, Red TRCW- Trim Ring, Ceiling, White HS Notes: 'Add "-P'' to model number for plain housing (no "FIRE" marking on cover), e.g., P2R-P. 1' Add "-SP" to model number for "FUEGO" marking on cover, e.g .. P2R-SP. :j: "Standard co" refers to strobes that include 15, 15/75. 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. ©2012 System Sensor. ~~SYSTEM 3825 Ohio Avenue• St. Charles, IL 60174 Product speer caucos sucect to change •Mtho~; notice. Visit svsre+se-scr.com Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product informa: on. 1nclucing the latest version of :riis data sheet '-~ SENSOR AVOS00501 • 3/12 Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic • Weatherproof per NEMA 4X, IP56 housings, wall or ceiling mounting options, and plain or FIRE-printed • Listed to UL 1638 (strobe) and UL 464 (horn) devices, SpeclrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement, including indoor, outdoor, wet, and dry applications in legacy SpectrAlert products temperatures from -40°F to 151°F. • Field-selectable candela settings: 15. 15/75. 30, 75, 95, 110, 115, Like the entire SpectrAlert Advance line, outdoor horns, strobes, 135, 150, 177, and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12- or 24-volt operation at 15 and that increase application flexibility and simplify installation. First, 15/75 candela field-selectable settings, including candela, automatic selection of • Rotary switch for horn tone and three volume selections 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. • Horn rated at 88+ dBA at 16 volts • Rated from ---40°F to 151°F Next, SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications. This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without • Plug-in design with minimal intrusion into the back box mounting the devices and exposing them to potential construction • Tamper-resistant construction damage. Once the plates are mounted, all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- Agency Listings out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill SIGNALING holes for screw-in mounting. Plastic and metal weatherproof back ® ~ boxes come with ¾-inch top and bottom conduit entries and ¾-inch Ll;TED ~ MEA 7300-1653: 187 (outdoor strob~s) 7125-1o53::18.3 (r.o,n secbes. knock-outs at the back. A screw-in NPT plug with an O-ring gasket s..eo11 (c!1ime~. hem svcbes. t1crns) APPROVED approved ctsme siroces) 53593 (outocor and alwt sircbesj 3:123572 MEl\•152-05----E 71~5""1053:180 {ho.ns, chime9) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit~ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts: 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist ot a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Hom Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 197·1 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151 °F (-40°c to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operaiing Voltage Range2 8 to 17.5 V ( 12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18AWG Wall-Mount Olmensions {including lens) 5.6"L x 4.rw x 2.5-D (142 mm L x 119 mm w x 64 mm D) Horn Dimensions 5.6"L x 4.?"W x 1.3·0 (142 mrn L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Sack Box Dimensions (SA-WBB) 5.?"L x 5.1"W x 2.0·0 (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR} voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 ed. AI/DS01201 UL Current Draw Data fili'ditf:irlnfihIUijJt~i&@,t1i1\Wii@ B-17.5Volts 16--33 Volts 8-17.5\/olls 16-33\/olts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWP. Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 i!lflrni"'ffi@iMii®il'AWlfM~¾tffi@bi•MW@ii-Mld 8--17.5 Volts 16-33 Volts DC Input 15 ·1s175 15 15ll5 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-- Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 M11Mi&rtt#Ni¼/dik$MI\U@O=®iW\Ri&fflfflfflitil~MW~it+#M ts-aaveus 16-33Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low . 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures. listed candela ratings must be reduced in accordance with lH7.5 16-33 24-Vo!t Nominal this table. Switch Sound Volts Volts Reverberant Anechoic ~@Ji~®~-_- ~ ©J~1-~~~~¥~~~~= p Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating al --40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 82 82 88 88 93 92 100 100 75 44 Temporal 95 70 5 Non- Medium 78 78 85 85 90 90 98 98 110 110 Temporal 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 st Coded Medium 78 78 85 85 90 90 97 98 gt Coded Low 75 75 81 81 88 85 96 92 185 185 'Settinqs 7, 8, and 9 are not available on 2-wire horn strobe. AVOS:Jl20\ SpectrAlert Advance Diagrams Wail-Mount Hom Strobes wan Plastic Weatherproof Back Box Wall-Mount Horn Strobe with Pfast!c Weatherproof Back Box SpectrAlert Advance Ordering Information > Wall Horn Strobes _P_2_R_K_-t 2_-Vi_✓_ire_H_o_rn_S_t_ro_b_e..:..' _S_ta_n_d_a_rd_c_d---',_R_e_d..c.,_O_u_td_o_o_r....:(_in_c_lu_d_e_s_,_p_la_s_tic_w_e_at_h_e-'-rp_ro_o_f_b_a_c_k_b_o_x'---) ---'---'------~-- P2RHK't 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK't 2-Wire Horn Slrobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4Rl,t 4-Wire Horn Strobe, Standard ed. Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard ed. White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wal! Strobes SRK't Strobe, Standard ed. Red, Outdoor (includes plastic weatherproof back box) SRHK'I Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK't Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK't Strobe, High ed. White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: • Add "-P" to model number for plain housing (no "FIRE" marking on cover), e.g., P2Rl~-P. t Add "-A" to model number for weatherproof replacement device (no back box included), cnly for use with wealherprool outdoor flush mounting plate, WTP and WTPW. 'Standard cd" relers to strobes that include 15, 15/75. 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candsla settings. When replacing standard outdoor units both the device and back box must be replaced. ©2012 System Sensor. 3825 Ohio Avenue• St. Charles, IL 60174 Prodoct specfceucns subject to ch.;r.ge vJtr.oui. norce. Vi~l syr.len\Ser~t . com Phone: B00-SENSOR2 • Fax: 630-377-6495 icr current orcccct in:'mmalioo, including the lercst versicn oi ::his daia steel . AVDS01201 • 3/1?