Loading...
HomeMy WebLinkAbout4511 195th Pl Ne_BLD5295_2025 Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551 Page 1 of 1 Permit Number: Permit Type: Address/Parcel: Completed (Month/Year): Land Use ˆ Notice of Decision ˆ Staff Report ˆ Application ˆ Narrative ˆ Legal Description ˆ Vicinity Map ˆ Site Plan ˆ Landscape Plan ˆ Complete Streets Checklist ˆ Traffic Impact Analysis ˆ Snohomish County Traffic Mitigation Offer ˆ WSDOT Traffic Offer Form ˆ Tree Survey ˆ Stormwater Drainage Report ˆ Geotech Report ˆ Critical Area Evaluation Form ˆ SEPA Checklist ˆ Public Notice Material ˆ Noticing and Related Documents ˆ Water / Sewer Availability Certificate ˆ Unanticipated Discovery Plan Form ˆ Aerial Photo of Site ˆ Proposed Building Materials ˆ Lighting Plans and Lighting Cut Sheets ˆ Color Elevations ˆ Design Matrix ˆ Plat Map ˆ Title Report ˆ Lot Closures ˆ Preliminary Civil Plans ˆ Archaeological Survey o Confidential Documents. Contact the City to obtain. ˆ Topography (Existing Conditions) ˆ CC&R’s ˆ Deeds / Easements / Conveyances /Dedications ˆ Developer’s Agreement ˆ Recorded Copies ˆ Bonding or Assignment of Funds o Confidential Documents. Contact the City to obtain. ˆ Letters and Project Documents ˆ Other: Civil ˆ Issued Permit ˆ Application ˆ Other Applications ˆ Construction Calculation Worksheet ˆ Approved Plans ˆ Review Comment Form ˆ Letters and Project Documents ˆ Other Agency Permits ˆ Reports: o Drainage Report Pg: o Stormwater Pg: o Geotech Pg: o All Other Reports ˆ SEPA and Noticing Materials ˆ Inspections ˆ As-Builts ˆ Other: Building ˆ Issued Permit ˆ Application ˆ Additional Applications ˆ Approved Plans ˆ Site Plan ˆ Letters and Project Documents ˆ Calculations ˆ Project Specification Manuals ˆ Reports ˆ Certificate of Occupancy ˆ Inspections ˆ Other: BLD5295 Residential Mechanical 4511 195th Pl Ne July 2023 ✔ ✔ ✔ CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 4511 195TH PL NE Parcel #: 00930600002500 Permit #: 5295 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work: Replace Furnace, Like for Like Replacement Valuation: 5000.00 OWNER APPLICANT CONTRACTOR SOLTERO SALVADOR/MONA Resicon LLC RESICON LLC 4511 195TH PL NE 6910 27th St W 3914 Center St ARLINGTON, WA 98223 University Place, WA 98466 Tacoma, WA 98409 253-625-7952 2536257952 LIC: RESICL*874OF EXP: 09/06/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC #:EXP:LIC #:EXP: JOB DESCRIPTION PERMIT TYPE:RESIDENTIAL MECHANICAL CODE YEAR:2018 STORIES:2 CONST. TYPE:VB DWELLING UNITS:OCC GROUP:R-3; Residential BUILDINGS:OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 04/13/2023 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved plans. Call for inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, 06/15/2023 MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 04/13/2023 Processing/Technology $25.00 04/13/2023 Inspection $75.00 04/13/2023 Mechanical Base $25.00 04/13/2023 Gas Piping/Units $15.00 04/13/2023 Forced Air Heat ≤ 100 BTU/h $15.00 04/13/2023 Credit Card Service $4.65 Total Due:$159.65 Total Payment:$159.65 Balance Due:$0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail RESIDENTIAL MECHANICAL APPLICATION Community and Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 REV03.2022 Page 1 of 2 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances MECHANICAL PERMIT FEES (per unit) Additional Plan Review fees x $ 75.00 = Air Cond. Unit ≤100Btu/h x $ 15.00 = Air Cond. Unit >100Btu/h x $ 25.00 = Air Cond. Unit >500Btu/h x $ 50.00 = Air Handling Units x $ 15.00 = Base Mechanical Fee 1 x $ 25.00 = $ 25.00 Boiler <100Btu/h >3hp x $ 15.00 = Boiler >1 million Btu/h<50hp x $ 25.00 = Type of Permit:  New Installation  Addition/Alteration/Repair  Gas Piping Property Address: Project Valuation: Lot #: Parcel ID No.: Preferred Contact:  Owner  Contractor Project Description: Owner Name: Home No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Contractor Name: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: Gas Piping Information  Not Applicable Proposed Piping Material:  CSST  Brass Other  Black Steel  Galvanized Steel _______________________________________ Proposed Piping Size:  ½”  ⅝”  ¾”  1”  1½”  2” Distance from Meter to furthest Appliance: Total BTU’s of all Appliances: 4 4511 195th Pl NE 5000.00 25 00930600002500 4 Replace Furnace Mona Soltaro 425-320-6207 N/A 4511 195th Pl NE Arlington WA 98223 Resicon LLC 253-625-7952 info@resiconllc.com 6910 27th ST W University Place WA 98466 RESICL*919N7 08/2023 4 REV2.2020 Page 2 of 2 MECHANICAL PERMIT FEES (per unit) Boiler >1.5 million Btu/h<50hp x $ 50.00 = Boiler >100Btu/h 3-15hp x $ 15.00 = Boiler >500Btu/h 15-30hp x $ 25.00 = Commercial Hoods -Type I x $ 25.00 = Commercial Hoods -Type II x $50.00 = Diffusers x $ 15.00 = Dryer Ducting x $ 15.00 = Ductwork (drawings required) x $ 25.00 = Evaporative Coolers x $ 15.00 = Exhaust/Ventilation Fans x $ 15.00 = Fireplace/Insert/Stove x $ 15.00 = Forced Air Heat ≤100 Btu/h x $ 15.00 = Forced Air Heat >100 Btu/h x $ 25.00 = Gas Clothes Dryer x $ 15.00 = Gas Fired AC ≤100 Btu/h x $ 15.00 = Gas Fired AC >100 Btu/h x $ 25.00 = Gas Fired AC > 500 Btu/h x $ 50.00 = Gas Piping ≤ 5 units x $ 15.00 = Gas Piping > 5 units (plus <5 units) x $ 2.00 = Heat Exchangers x $ 15.00 = Heat Pump-Condensing Unit x $ 25.00 = Hot Water Heat Coils x $ 15.00 = Miscellaneous Appliance - regulated by mechanical code, not otherwise specified x $ 15.00 = Pkg. Units ≤100btu x $ 25.00 =Pkg. Units >100btu x $50.00 = Range/Cook top-Gas Fired x $ 15.00 =Refrigeration Unit ≤100Btu/h x $ 15.00 =Refrigeration Unit >100Btu/h x $ 25.00 =Refrigeration. Unit >500Btu/h x $ 50.00 =Re-inspection fee x $ 75.00 =Residential Range Hood x $ 15.00 =Unit Heaters ≤ 100 Btu/h x $ 15.00 =Unit Heaters >100 Btu/h x $ 25.00 =VAV Boxes (Variable Air Volume, part of air conditioning system) x $ 10.00 = Wall Heaters - Gas Fired x $ 25.00 =Water Heater - Gas Fired x $ 25.00 =Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total 1 15.00 40.00 140.00 REV2.2020 Page 3 of 3 PRESSURE PIPING SCHEMATICCOMPLETE FOR GAS PIPING ONLY SCHEMATIC IS TO SCALE SCHEMATIC NOT TO SCALEShow Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated I hereby certify that I am the Owner, Applicant, Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. A final inspection and approval shall be obtained when complete. Signature Print Name Date 4 Jennifer Partosa 04/12/23 SAVE PRINT 95.0% AFUE STANDARD ECM SINGLE STAGE MULTI-POSITION RESIDENTIAL GAS FURNACES MODELS: RGF19*E NATURAL GAS 40 - 120 MBH INPUT Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.upgnet.com Additional rating information can be found at www.ahridirectory.org WARRANTY SUMMARY A 20-year limited warranty on heat exchangers in residential applications. A 10-year warranty on the heat exchanger in commercial applications. Standard 5-year limited Parts warranty. Extended lifetime heat exchanger and 10-year limited parts warranty when product is registered online within 90 days of purchase for replacement or closing for new home construction. See Limited Warranty certificate in Users Information Manual for details. TECHNICAL GUIDE GUIDE 1104783-UTG-F-0317 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE DESCRIPTION These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications. These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation. These units are Category IV, National Fuel Gas Code and may be vented either through side wall or roof applications using approved plastic combustion air and vent piping. Approved plastic combustion air and vent piping include Selkirk Polyflue, DuraVent Polypro, & Cen- trotherm Innoflue polypropylene venting systems. FEATURES • Easily applied in upflow, horizontal left or right, or downflow instal- lation with minimal conversion necessary. • Compact, easy to install, ideal height 33" tall cabinet. • Blower-off delay for cooling SEER improvement. • Easy access to controls to connect power/control wiring. • Built-in, high level self diagnostics with fault code displays stan- dard on integrated control module for reliable operation. • Low unit amp requirement for easy replacement application. • The RGF19026AE Model is not convertible for use with propane (LP) gas. All other RGF19*E Models are field convertible to use propane (LP) gas with optional propane conversion kit accessory. • Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability. • 100% shut off main gas valve for extra safety. • 5 speed, direct drive Standard ECM style high efficiency DC motor. • 24V, 40 VA control transformer and blower relay supplied for add- on cooling. • Hi-tech tubular aluminized steel primary heat exchanger. • Secondary heat exchanger made of corrosion resistant stainless steel materials. • Timed on, adjustable off blower capability for maximum comfort. • Blower door safety switch. • Airflow leakage less than 1% of nominal airflow at duct perfor- mance testing conditions. • No knockouts to deal with, making installation easier. • Movable duct connector flanges for application flexibility. • Quiet inducer operation. • Inducer rotates for easy conversion of venting options. • Fully supported blower assembly for easy access and removal of blower. • External air filters used for maximum flexibility in meeting custom- ers IAQ needs. • Protection included from air intake, exhaust vent, or condensate blockage. • Patent pending self priming internal condensate trap design for easy installation. • Venting applications - may be installed as a either 2-pipe (sealed combustion) or single-pipe vent (using indoor combustion air. • No special vent termination required. • 1/4 turn knobs provided for easy door removal. • High-efficiency blower motor for lower electrical power usage and improved A/C SEER ratings. • Insulated blower compartment for terminal and acoustic perfor- mance. 1104783-UTG-F-0317 2 Johnson Controls Unitary Products NOTES: Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water. FRONT 33 A LEFT SIDE Combustion Air Inlet Condensate Drain (Downflow) Vent Outlet Thermostat Wiring 28.5” Gas Pipe Entry Electrical Entry Condensate Drain Thermostat Wiring RIGHT SIDE Vent Outlet Condensate Drain (Downflow) 14” 1” 1.5” 23” Combustion Air Inlet Gas Pipe Entry Electrical Entry Condensate Drain Optional Return Air Cutout (Either side) 29.5” C SUPPLY END .56” .56” 20” B 3”23.8” .56” Combustion Air Inlet Vent Outlet RETURN END B 24.25” Cabinet & Duct Dimensions BTUH (kW) Input Nominal CFM (m3/min) Cabinet Size Cabinet Dimensions (Inches)Approximate Operating Weights A B C Lbs RGF19026AE08MP12 800 A 14 1/2 13 3/8 11 3/4 113 RGF19060BE12MP12 1200 B 17 1/2 16 3/8 13 1/4 122 RGF19080BE12MP12 1200 B 17 1/2 16 3/8 14 3/4 126 RGF19080CE16MP12 1600 C 21 19 7/8 16 1/2 136 RGF19100CE16MP12 1600 C 21 19 7/8 18 1/4 142 RGF19100CE20MP12 2000 C 21 19 7/8 18 1/4 145 RGF19120DE20MP12 2000 D 24 1/2 23 3/8 21 3/4 156 Ratings & Physical / Electrical Data BTUH (kW) Input Output Nominal Airflow AFUE Air Temp. Rise Max. Outlet Air Temp Blower Blower Size Max Over-Current Protect Total Unit Amps Min. wire Size (awg) @ 75 ft one wayMBH CFM %°F °F HP Amps RGF19026AE08MP12 26 25 96.0 25-55 190 1/3 4.4 11x8 15 7.1 14 RGF19060BE12MP12 60 57 95.5 30-60 190 1/2 6.8 11x8 15 9.5 14 RGF19080BE12MP12 80 76 95.5 40-70 190 1/2 6.8 11x8 15 9.5 14 RGF19080CE16MP12 80 76 95.5 35-65 190 1/2 6.8 11x10 15 9.5 14 RGF19100CE16MP12 100 95 95.5 40-70 190 1/2 6.8 11x10 15 9.5 14 RGF19100CE20MP12 100 95 95.5 35-65 190 3/4 8.4 11x11 15 10.9 14 RGF19120DE20MP12 120 114 95.5 45-75 190 3/4 8.4 11x11 15 10.9 14 1104783-UTG-F-0317 Johnson Controls Unitary Products 3 FILTER PERFORMANCE The airflow capacity data published in the “Blower Perfor- mance” table shown represents blower performance WITHOUT filters. All applications of these furnaces require the use of field installed air filters. All filter media and mounting hardware or provisions must be field installed external to the furnace cabi- net. DO NOT attempt to install any filters inside the furnace. 1. Air velocity through throwaway type filters may not exceed 300 feet per min- ute (91.4 m/min). All velocities over this require the use of high velocity fil- ters. 2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For CFM greater than 1800, you may use two side returns or one side and the bottom or one return with a transition to allow use of a 20x25 filter. *- 24" clearance in front and 18" on side recommended for service access. All furnaces approved for alcove and attic installation. ACCESSORIES Propane (LP) Conversion Kit - This accessory conversion kit may be used to convert natural gas units for LP operation. S1-1NP0347 - All Models except 26K S1-1NP0820 - Same as S1-1NP0347 except includes stainless steel LP burners. LP Stainless Steel Burner Kit - This accessory conversion kit may be used to convert existing burners to stainless steel burn- ers for LP use only. Kit contains 6 burners. The 130K Model requires 1 extra burner (P/N S1-02926889000). S1-32926889000 - All LP Models Natural (NAT) Gas Stainless Steel Burner Kit - This acces- sory kit may be used to replace existing burners with stainless steel burners for NAT gas use only. Kit contains 6 burners. The 130K Model requires 1 extra burner (P/N S1-02924441000). S1-32924441000 - All NAT gas Models Concentric Vent Termination - For use through rooftop, side- wall. Allows combustion air to enter and exhaust to exit through single common hole. Eliminates unsightly elbows for a cleaner installation. S1-1CT0302 (2") & S1-1CT0302-636 (2") S1-1CT0303 (3") & S1-1CT0303-636 (3") Sidewall Vent Termination Kit - For use on sidewall, two-pipe installations only. Provide a more attractive termination for loca- tions where the terminal is visible on the side of the home. S1-1HT0901 (3") S1-1HT0902 (2") Condensate Neutralizer Kit - Neutralizer cartridge has a 1/2” plastic tube fittings for installation in the drain line. Calcium car- bonate refill media is also available from the Source 1 Parts (P/N 026-30228-000). S1-1NK0301 Side Return Filter Racks - The S1-1SR0200 Kit accommo- dates a 1”, 2” or 4” filter. The S1-1SR0402 Kit accommodates a 1” filter only. S1-1SR0200 - All Models S1-1SR0402 - All Models Bottom Return Filter Racks - The S1-1BR05* series are gal- vanized steel filter racks. The S1-1BR06* series are pre-painted steel filter racks to match the appearance of the furnace cabi- net. The S1-1BR05* and S1-1BR06* series filter racks accom- modate a 1”, 2” or 4” filter. S1-1BR0517 or S1-1BR0617 - For 17-1/2” cabinets S1-1BR0521 or S1-1BR0621 - For 21” cabinets S1-1BR0524 or S1-1BR0624 - For 24-1/2” cabinets Combustible Floor Base Kit - These kits are required to pre- vent potential overheating situations when the furnaces are installed in downflow applications directly onto combustible flooring material. These kits are also required in any applica- tions where the furnace is installed in a downflow configuration without an indoor coil and where the combustible floor base kit provides access for combustible airflow. S1-1CB0517 - For 17-1/2” cabinets S1-1CB0521 - For 21” cabinets S1-1CB0524 - For 24-1/2” cabinets High Altitude Pressure Switches - For installation where the altitude is less than 5,000 feet, it is not required that the pres- sure switch be changed. For altitudes above 5,000 feet, see kits below. S1-1PS3306 - 060 S1-1PS3307 - 026, 040, 080 S1-1PS3302 - 100, 120 Thermostats - Compatible thermostat controls are available through accessory sourcing. For optimum performance, these outdoor units are fully compatible with our residential touch screen thermostat with proprietary (patent-pending) hexagon interface. For more information, see the thermostat section of the Product Equipment Catalog. S1-THXU280 - All Models NOTICE Single side return above 1800 CFM is approved as long as the filter velocity does not exceed filter manufacturer’s rec- ommendation and a transition is used to allow use on a 20x25 filter. Recommended Filter Sizes (High velocity 600 FPM) CFM (m³/min) Cabinet Size Side (in) Bottom (in) 800 (22.6)A 16 x 25 14 x 25 1200 (34.0)B 16 x 25 16 x 25 1600 (45.3)C 16 x 25 20 x 25 2000 (56.6)C (2 ea) 16 x 25 20 x 25 2000 (56.6)D (2 ea) 16 x 25 22 x 25 NOTES: Unit Clearances to Combustibles Application Upflow Downflow Horizontal Top 1" 0" 0" Vent 0" 0" 0" Rear 0" 0" 0" Side*0" 0" 1" Front*0" 0" 0" Floor Combustible Combustible1 1. For combustible floors only when used with special sub-base. Combustible Closet Yes Yes Yes Line Contact No No Yes NOTES: Subject to change without notice. Published in U.S.A.1104783-UTG-F-0317 Copyright © 2017 by Johnson Controls, Inc. All rights reserved.Supersedes: 1104783-UTG-E-1016 York International Corp. 5005 York Drive Norman, OK 73069 NOTES: 1. Airflow expressed in standard cubic feet per minute (CFM). 2. Motor voltage at 115 V. Blower Performance CFM - Any Position (without filter) Models Speed Bottom Airflow Data (SCFM) Ext. Static Pressure (in. H2O) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 RGF19026AE08MP12 High 955 928 895 862 829 797 765 730 690 665 Medium High 766 731 696 656 626 589 557 532 497 469 Medium 665 625 586 554 518 482 449 419 NR NR Medium Low 630 594 560 520 483 451 419 NR NR NR Low 562 514 474 435 395 365 NR NR NR NR RGF19060BE12MP12 High 1402 1374 1354 1328 1299 1262 1222 1167 1107 1036 Medium High 1252 1233 1203 1182 1150 1125 1095 1064 1031 980 Medium 1076 1059 1029 1007 973 946 908 883 843 800 Medium Low 988 967 936 903 875 838 806 765 737 685 Low 798 769 727 695 650 619 574 517 485 443 RGF19080BE12MP12 High 1445 1423 1397 1365 1339 1311 1283 1250 1204 1140 Medium High 1282 1266 1232 1211 1182 1157 1128 1097 1069 1013 Medium 1098 1084 1059 1027 998 967 939 910 879 822 Medium Low 1012 993 953 930 894 851 828 773 752 692 Low 865 810 763 730 689 628 594 520 496 448 RGF19080CE16MP12 High 1713 1682 1643 1600 1558 1519 1480 1436 1385 1333 Medium High 1554 1519 1485 1439 1404 1368 1327 1280 1176 1130 Medium 1380 1351 1302 1263 1224 1171 1128 1085 1030 943 Medium Low 1177 1142 1083 1050 988 922 890 819 798 687 Low 951 841 650 588 457 418 355 227 203 N / A RGF19100CE16MP12 High 1734 1694 1650 1611 1570 1536 1485 1438 1392 1335 Medium High 1568 1537 1492 1453 1414 1373 1327 1279 1230 1118 Medium 1420 1380 1332 1294 1249 1196 1152 1100 981 938 Medium 1218 1169 1124 1067 1015 965 894 845 754 679 Low 979 846 647 580 464 427 345 220 195 N / A RGF19100CE20MP12 High 2143 2102 2065 2028 1989 1944 1892 1825 1733 1625 Medium High 1788 1749 1718 1672 1629 1587 1541 1500 1447 1355 Medium 1575 1539 1500 1456 1410 1363 1305 1246 1095 1030 Medium Low 1372 1325 1276 1225 1170 1111 1044 972 884 812 Low 1031 921 810 728 660 615 518 474 391 355 RGF19120DE20MP12 High 2214 2173 2132 2086 2036 1994 1952 1907 1849 1777 Medium High 1841 1799 1749 1699 1659 1611 1567 1520 1471 1372 Medium 1605 1562 1514 1470 1416 1361 1310 1180 1119 1045 Medium Low 1405 1362 1303 1244 1189 1125 1054 986 876 826 Low 1135 1020 844 758 671 557 511 464 387 N / A