Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18118 Woodbine Dr_BLD5397_2025
Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551 Page 1 of 1 Permit Number: Permit Type: Address/Parcel: Completed (Month/Year): Land Use Notice of Decision Staff Report Application Narrative Legal Description Vicinity Map Site Plan Landscape Plan Complete Streets Checklist Traffic Impact Analysis Snohomish County Traffic Mitigation Offer WSDOT Traffic Offer Form Tree Survey Stormwater Drainage Report Geotech Report Critical Area Evaluation Form SEPA Checklist Public Notice Material Noticing and Related Documents Water / Sewer Availability Certificate Unanticipated Discovery Plan Form Aerial Photo of Site Proposed Building Materials Lighting Plans and Lighting Cut Sheets Color Elevations Design Matrix Plat Map Title Report Lot Closures Preliminary Civil Plans Archaeological Survey o Confidential Documents. Contact the City to obtain. Topography (Existing Conditions) CC&R’s Deeds / Easements / Conveyances /Dedications Developer’s Agreement Recorded Copies Bonding or Assignment of Funds o Confidential Documents. Contact the City to obtain. Letters and Project Documents Other: Civil Issued Permit Application Other Applications Construction Calculation Worksheet Approved Plans Review Comment Form Letters and Project Documents Other Agency Permits Reports: o Drainage Report Pg: o Stormwater Pg: o Geotech Pg: o All Other Reports SEPA and Noticing Materials Inspections As-Builts Other: Building Issued Permit Application Additional Applications Approved Plans Site Plan Letters and Project Documents Calculations Project Specification Manuals Reports Certificate of Occupancy Inspections Other: BLD5397 Residential Mechanical 18118 Woodbine Dr EXPIRED January 2024 ✔ ✔ ✔ ✔ TAG:______________________________ SSAAFFEETTYY WWAARRNNIINNGG Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. July 2019 SS99XX22BB008800DD44--SSUUBB--11CC--EENN Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH DDoowwnnffllooww OOnnllyy S9X2B080D4PSBA NNoottee::Graphics in this document are for representation only.Actual model may differ in appearance. Submittal 2 S9X2B080D4-SUB-1C-EN Outline Drawings Downow Furnace B S ize Cabinet S9X2B080D4-SUB-1C-EN 3 Product Specifications MODEL S9X2B080D4PSBA (a) TYPE Downflow RATINGS (b) 1st Stage Input BTUH (ICS)52,000 1st Stage Capacity BTUH 50,440 2nd Stage Input BTUH 80,000 2nd Stage Capacity BTUH (ICS)(c)(d)77,600 1st Stage Temp.Rise (Min.-Max.)30 -60 2nd Stage Temp.Rise (Min.-Max.)45 -75 AFUE (%)96.0 BLOWER DRIVE DIRECT Diameter —Width (In.)11 X 8 No.Used 1 Speeds (No.)(e)9 CFM vs.in.w.g.See Fan Performance Table Motor HP 3/4 RPM 1075 Volts/Ph/Hz 120 /1 /60 FLA 9.3 COMBUSTION FAN —Type Centrifugal Drive —No.Speeds Direct -2 Motor HP —RPM 3300/2600 Volts/Ph/Hz 120 /1 /60 FLA 0.66 FILTER —Furnished?No Type recommended High Velocity Hi Vel.(No.-Size-Thk.)2 —14x20 —1 in. VENT PIPE DIAMETER —Min (in.) (f)(g)2 Round HEAT EXCHANGER Type —Fired 409 Stainless Steel MODEL S9X2B080D4PSBA (a) —Unfired 29–4C Stainless Steel Gauge (Fired)20 ORIFICES —Main Nat.Gas Qty.—Drill Size 4 -45 LP Gas Qty.—Drill Size 4-56 GAS VALVE Redundant -Two Stage PILOT SAFETY DEVICE Type 120 V SiNi Igniter BURNERS —Type Multiport Inshot Number 4 POWER CONN.—V/Ph/Hz (h)120 /1 /60 Ampacity (In Amps)12.4 Max.Overcurrent Protection (Amps)15 PIPE CONN.SIZE (in.)1/2 DIMENSIONS H x W x D Uncrated (In.)34 x 17-1/2 x 28–3/4 Crated (In.)35-1/2 x 19-1/2 x 30-7/8 WEIGHT Shipping (Lbs.)/Net (Lbs.)135/127 (a)Meets Energy Star (b)For U.S.applications,above input ratings (BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applications,above input ratings (BTUH)are up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. (c)Central Furnace heating designs are certified to ANSI Z21.47 /CSA 2.3. (d)Based on U.S.government standard tests. (e)9 Speed constant torque ECM blower motor (f)Refer to the Vent Length Table in the Installer's Guide. (g)All S9X2 furnace models have a vent outlet diameter that equals 2 in. (h)The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. 4 S9X2B080D4-SUB-1C-EN Airflow tables Furnace Airflow (CFM)Vs.External Static Pressure (in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 S9X1B080D4PSBA S9B1B080D4PSAA S9X2B080D4PSBA 1 SCFM 499 306 113 -- Watts 36 43 49 -- 2 SCFM 1017 922 828 734 640 Watts 143 158 173 188 203 3 SCFM 1119 1029 940 850 761 Watts 176 192 207 223 239 4 SCFM 1205 1125 1044 964 883 Watts 215 233 250 268 285 5 SCFM 1237 1160 1083 1006 928 Watts 231 250 268 286 305 6 SCFM 1378 1309 1240 1172 1103 Watts 315 334 354 373 393 7 SCFM 1453 1389 1324 1260 1195 Watts 360 380 399 419 439 8 SCFM 1618 1562 1505 1449 1392 Watts 496 518 540 561 583 9 SCFM 1794 1742 1691 1639 1587 Watts 682 704 726 748 770 S9X2B080D4-SUB-1C-EN 5 CFM Versus Temperature Rise Table 1.2nd Stage Heating Table —Downflow CFM VS.2ND STAGE TEMPERATURE RISE MODEL 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 S9X2B080D4PSBA 72 65 60 55 51 48 Table 2.1st Stage Heating Table —Downflow CFM VS.1ST STAGE TEMPERATURE RISE MODEL 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 S9X2B080D4PSBA 60 55 51 48 45 42 40 38 36 34 6 S9X2B080D4-SUB-1C-EN General Features NNAATTUURRAALL GGAASS MMOODDEELLSS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas.Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SSAAFFEE OOPPEERRAATTIIOONN The Integrated System Control is a solid state device which continuously monitors for presence of flame when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide additional safety. QQUUIICCKK HHEEAATTIINNGG Durable,cycle tested,heavy gauge ttuubbuullaarr ssttaaiinnlleessss sstteeeell pprriimmaarryy hheeaatt eexxcchhaannggeerr quickly transfers heat to provide warm conditioned air to the structure.LLooww eenneerrggyy ppoowweerr vveenntt bblloowweerr,,to increase efficiency and provide a positive discharge of gas fumes to the outside. BBUURRNNEERRSS Multiport Inshot burners will give years of quiet and efficient service.All models can be converted to LL..PP.. ggaass with LP conversion kit. IINNTTEEGGRRAATTEEDD SSYYSSTTEEMM CCOONNTTRROOLL Exclusively designed operational program provides total control of furnace limit sensors,blowers,gas valve,flame control and includes self diagnostics for ease of service.Also contains dry contacts for EAC and HUM. EENNEERRGGYY EEFFFFIICCIIEENNTT OOPPEERRAATTIIOONN Furnace is certified by the manufacturer to leak 1%or less of nominal air conditioning CFM delivered when pressurized to .5"water column with all inlets,outlets, and drains sealed. AAIIRR DDEELLIIVVEERRYY The variable speed blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. SSEECCOONNDDAARRYY HHEEAATT EEXXCCHHAANNGGEERR The S-Series furnace has a special type 29-4C™ stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost. SSTTYYLLIINNGG HHeeaavvyy ggaauuggee sstteeeell aanndd ""wwrraapp--aarroouunndd""ccaabbiinneett ccoonnssttrruuccttiioonn is used in the cabinet with baked-on enamel finish for strength and beauty.Every orientation has at least two venting options.There are no knockouts on cabinet. FFEEAATTUURREESS AANNDD GGEENNEERRAALL OOPPEERRAATTIIOONN The S-Series furnace utilizes a Silicon Nitride Hot Surface Ignition system,which eliminates the waste of a constant burning pilot.The integrated system control lights the main burners upon a demand for heat from the room thermostat.Complete front service access. a.Low energy power venter b.Vent proving pressure switches. S9X2B080D4-SUB-1C-EN 7 Features and Benefits UUPP TTOO 9966..00%%AAFFUUEE OONN SS99XX22 FFUURRNNAACCEE MMOODDEELLSS Meets utility rebates Lowers utility bills EELLEECCTTRRIICCAALLLLYY EEFFFFIICCIIEENNTT Efficient airflow design reduces electrical energy use 3344 IINNCCHH TTAALLLL Lighter,easier to move and fit into tight spaces like short basements or tight closets Works great with larger,high-efficiency coils No knockouts 33––WWAAYY MMUULLTTII--PPOOIISSEE //DDEEDDIICCAATTEEDD DDOOWWNNFFLLOOWW 11 SKU’s —Upflow /Horizontal Left /Horizontal Right 5 SKU’s —Downflow Added application flexibility and reduction in specification errors AAIIRRFFLLOOWW At least 400 CFM/ton at 0.5 in.H20 external static pressure;setup airflow options down to 290 CFM/ton RREEGGUULLAATTOORRYY All models are air tight;1%or less air leakage as per ASHRAE 193 Open vestibule design provides a full 34”high open vestibule DDIIMMEENNSSIIOONNSS Widths are industry standard:17.5”,21”,and 24.5” Depth remains approximately 28” Cabinet will be compatible with industry standard coils, as well as,other accessories IINNTTEEGGRRAATTEEDD FFUURRNNAACCEE CCOONNTTRROOLL Setup /Status /Diagnostics /Digital Display No dip switches Last six errors stored Dry contact EAC and HUM connections All Molex connections;no spade terminals Low voltage labeled above and below Rain shield over IFC keeps condensate off the control TTUUBBUULLAARR SSTTAAIINNLLEESSSS SSTTEEEELL PPRRIIMMAARRYY HHEEAATT EEXXCCHHAANNGGEERR 2299––44CC SSTTAAIINNLLEESSSS SSTTEEEELL SSEECCOONNDDAARRYY HHEEAATT EEXXCCHHAANNGGEERR Stainless steel is a more durable,corrosive-resistant material than aluminumized steel Integrated rail system for easy access if required Reduces or eliminates need for baffles VVOORRTTIICCAA IIII BBLLOOWWEERR,,DDEESSIIGGNNEEDD EEXXCCLLUUSSIIVVEELLYY FFOORR TTHHEE SS--SSEERRIIEESS FFUURRNNAACCEE Improved airflow efficiency Durable,easy to clean,two piece housing Single piece belly band/motor arm assembly Blower deck has full-length rails for easy removal and replacement,regardless of poise TTHHRREEEE––WWAAYY MMUULLTTII--PPOOIISSEE ((UUPPFFLLOOWW,, HHOORRIIZZOONNTTAALL LLEEFFTT AANNDD RRIIGGHHTT))PPLLUUSS DDEEDDIICCAATTEEDD DDOOWWNNFFLLOOWW Easier to specify Shipped ready to install (no conversion kits required) Every model has at least two venting options When in horizontal,trap extends only about 2” Barbed fitting on trap at hose connection and on cabinet transition for hose has barbed fitting and clamps at both ends for leak resistance. Vent table improvements including longer vent lengths;2”pipe can be used up to 100K Ingersoll Rand (NYSE:IR)advances the quality of life by creating comfortable,sustainable and efficient environments.Our people and our family of brands —including Club Car®,Ingersoll Rand®,Thermo King®and Trane®—work together to enhance the quality and comfort of air in homes and buildings;transport and protect food and perishables;and increase industrial productivity and efficiency.We are a global business committed to a world of sustainable progress and enduring results. ingersollrand.com Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. S9X2B080D4-SUB-1C-EN 31 Jul 2019 Supersedes S9X2B080D4-SUB-1B-EN (July 2018)©2016 Ingersoll Rand April 2020 44AA77AA33003366HH––SSUUBB--11EE--EENN Split System Cooling 3.0 Ton 4A7A3036H1000N Submittal 2 4A7A3036H–SUB-1E-EN SERVICE PANEL ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT AND SHOULD BE AT LEAST 305 (12”) FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED ELECTRICAL SERVICE PANEL 25 (1) 22.2 (7/8) DIA. HOLE LOW VOLTAGE 28.6 (1-1/8) DIA. K.O. WITH 22.2 (7/8) DIA. HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPLY LIQUID LINE SERVICE VALVE, “E” I.D. FEMALE BRAZE CONNECTION WITH 1/4” SAE FLARE PRESSURE TAP FITTINGS K H F J G FIG. 1 K.O. FOR ALTERNATE ELECTRICAL ROUTING GAS LINE 1/4 TURN BALL SERVICE VALVE, “D” I.D. FEMALE BRAZED CONNECTION WITH 1/4” SAE FLARE PRESSURE TAP FITTING.A From Dwg. D152898 Model Base A B C D E F G H J K 4A7A3036H 3 730 (28–3/4) 829 (32–5/8) 756 (29–3/4)3/4 3/8 137 (5–3/8) 79 (3–1/8) 197 (7–3/4) 60 (2–3/8) 508 (20) SOUND POWER LEVEL Model A-Weighted Sound Power Level [dB(A)] Full Octave Sound Power [dB] 63 Hz*125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A7A3036H 68 74.7 65.0 65.2 66.4 63.6 58.7 56.3 52.8 Note:Rated in accordance with AHRI Standard 270–2008 *For reference only66 4A7A3036H–SUB-1E-EN 3 Product Specifications OUTDOOR UNIT (a)(b)4A7A3036H1000N POWER CONNS.—V/PH/HZ (c)208/230/1/60 MIN.BRCH.CIR.AMPACITY 18 BR.CIR.PROT.RTG.—MAX.(AMPS)30 COMPRESSOR DURATION™-SCROLL NO.USED —NO.STAGES 1 —1 VOLTS/PH/HZ 208/230/1/60 R.L.AMPS (d)—L.R.AMPS 14.1 —75 FACTORY INSTALLED START COMPONENTS (e)NO INSULATION/SOUND BLANKET NO COMPRESSOR HEAT NO OUTDOOR FAN PROPELLER DIA.(IN.)—NO.USED 23 —1 TYPE DRIVE —NO.SPEEDS DIRECT —1 CFM @ 0.0 IN.W.G.(f)2900 NO.MOTORS —HP 1 —1/8 MOTOR SPEED R.P.M.825 VOLTS/PH/HZ 200/230/1/60 F.L.AMPS 0.7 OUTDOOR COIL —TYPE SPINE FIN™ ROWS —F.P.I.1 —24 FACE AREA (SQ.FT.)12.89 TUBE SIZE (IN.)3/8 REFRIGERANT LBS.—R-410A (O.D.UNIT)(g)4 LBS.,2 OZ FACTORY SUPPLIED YES LINE SIZE —IN.O.D.GAS (h)3/4 LINE SIZE —IN.O.D.LIQ.3/8 CHARGING SPECIFICATIONS SUBCOOLING 10°F DIMENSIONS H X W X D CRATED (IN.)34 x 30.1 x 33 WEIGHT SHIPPING (LBS.)175 NET (LBS.)147 (a)Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program,which is based on AHRI standard 210/240. (b)Rated in accordance with AHRI standard 270. (c)Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers or fuses. (d)This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the branch circuit selection current. (e)Use start components only when compressor is found to enter locked rotor condition and will not start or when lights dim at compressor start.No means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter. Optional kit shown. (f)Standard Air —Dry Coil —Outdoor (g)This value approximate.For more precise value see unit nameplate. (h)Max.linear length 60 ft.;Max.lift —Suction 60 ft.;Max.lift —Liquid 60 ft.For greater length consult refrigerant piping software Pub.No. 32–3312–0*(*denotes latest revision). 4 4A7A3036H–SUB-1E-EN Mechanical Specification Options GGeenneerraall The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit,ten (10)feet of tested connecting line,and the smallest rated indoor evaporative coil match.This unit is designed to operate at outdoor ambient temperatures as high as 115°F.Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified.The unit is certified to UL 1995.Exterior is designed for outdoor application. CCaassiinngg Unit casing is constructed of heavy gauge,galvanized steel and painted with a weather-resistant powder paint finish.The corner panels are prepainted.All panels are subjected to our 1,000 hour salt spray test. RReeffrriiggeerraanntt CCoonnttrroollss Refrigeration system controls include condenser fan, compressor contactor and low and high pressure switches.A factory supplied,field installed liquid line drier is standard. CCoommpprreessssoorr The compressor features internal over temperature and pressure protection.Other features include:Centrifugal oil pump and low vibration and noise. CCoonnddeennsseerr CCooiill The outdoor coil provides low airflow resistance and efficient heat transfer.The coil is protected on all four sides by louvered panels. LLooww AAmmbbiieenntt CCoooolliinngg As manufactured,this system has a cooling capacity to 55°F.The addition of an evaporator defrost control permits operation to 40°F.The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. The addition of the BAYLOAM107A low ambient kit permits ambient cooling to 20°F. TThheerrmmoossttaattss—Cooling only and heat/cooling (manual and automatic change over).Sub-base to match thermostat and locking thermostat cover. About American Standard Heating and Air Conditioning American Standard has been creating comfortable and affordable living environments for more than a century.For more information,please visit www.americanstandardair.com. The AHRI Certified mark indicates company participation in the AHRI Certification program.For verification of individual certified products,go to ahridirectory.org. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 4A7A3036H–SUB-1E-EN 28 Apr 2020 Supersedes 4A7A3036H–SUB-1D-EN (November 2019)©2020 American Standard Heating and Air Conditioning