Loading...
HomeMy WebLinkAbout20325 71st Ave Ne_BLD6692_2025 CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 20325 71ST AVE NE Permit #: 6692 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 00769800000700 DATE OF ISSUANCE. Scope of Work: modification of sprinkler protection to existing space to conform with Valuation: 8400.00 new clean room addition. OWNER APPLICANT CONTRACTOR JENSEN BUSINESS PARKS LLC Burns Fire Protection Systems, Inc. Burns Fire Protection Systems 20613 OLD BURN HILL RD PO Box 1110 PO Box 1110 ARLINGTON, WA 98223 Granite Falls Granite Falls, WA 98252 3606912235 360-691-2235 LIC: 603 467 812 EXP: 03/31/2026 LIC: BURNSFP841DU EXP: 04/14/2026 LIC: 86528 EXP: 12/01/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC #: EXP: LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE SPRINKLER CODE YEAR: 2021 STORIES: 1 CONST. TYPE: lA DWELLING UNITS: OCC GROUP: A-1; Assembly BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 09-08-2025 09/08/2025 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved plans. Permit shall be onsite for inspections. Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/08/2025 Web Only - Fire System Plan Review $200.00 09/08/2025 Processing/Technology $25.00 09/08/2025 Fire Sprinkler System $450.00 Total Due: $675.00 Total Payment: $675.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail x 20325 71st Ave NE 8,400 00769800000700 modification of sprinkler protection to existing space to conform with new clean room addition. Jensen Business Parks LLC 20613 Old Burn Hill Rd Arlington WA 98223 Keith Kyle 425-905-5780 Keith@burnsfire.com PO Box 1110 Granite Falls WA 98252 Burns Fire Protection Systems, Inc. 360-691-2235 audra@burnsfire.com PO Box 1110 Granite Falls WA 98252 x 225.00 15 x 450.00 450.00 251.26 726.26 x Keith Kyle 08-28-2025 Burns Fire Protection Systems, Inc. P.O. Box 1110 Granite Falls, WA 98252 PH: (425) 388-0124 Senior Aerospace TI 20325 71st Ave NE Arlington, WA 98223 Item No DESCRIPTION MANUFACTURER MFG. NO. FINISH REMARKS Electric Bell Potter Sprinkler Head Tyco TY3231 Chr 200° 5.6k Storage Cabinet FPPI Red Steel Pipe Bull Moose Sch 10/40 | Eddy Flow Blk Sammy Screw All Buildex Hangers Caddy Seismic Bracing Afcon AF730 Sway Brace Afcon AF001 Grooved Coupling Victaulic 009H Orange Grooved Fitting Victaulic Orange Mech Tee Tyco 730 Orange Threaded Fittings Shurjoint Blk Worldwide www.tyco-fire.com Contacts Series TY-FRB – 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General to corrosive atmospheres. Although corrosion-resistant coated sprinklers Description have passed the standard corrosion tests of the applicable approval agen- cies, the testing is not representative The TYCO Series TY-FRB 2.8, 4.2, 5.6, of all possible corrosive atmospheres. and 8.0 K-factor Upright, Pendent, Consequently, it is recommended that and Recessed Pendent Sprinklers the end user be consulted with respect described in herein are quick response, to the suitability of these coatings for standard coverage, decorative 3 mm any given corrosive environment. The glass bulb-type spray sprinklers. They effects of ambient temperature, con- are designed for use in light or ordinary centration of chemicals, and gas/ hazard, commercial occupancies such chemical velocity, should be consid- as banks, hotels, and shopping malls. ered, as a minimum, along with the cor- The TY-FRB Recessed Pendent Sprin- rosive nature of the chemical to which kler, where applicable, is intended for the sprinklers will be exposed. use in areas with a finished ceiling. This An intermediate level version of the recessed pendent sprinkler uses one of Series TY-FRB Pendent Sprinklers the following Recessed Escutcheons: is detailed in Technical Data Sheet • A two-piece Style 10 (1/2 in. NPT) TFP356. Sprinkler Guards are detailed or Style 40 (3/4 in. NPT) Recessed in Technical Data Sheet TFP780. Escutcheon with 1/2 in. (12,7 mm) of recessed adjustment or up to 3/4 in. NOTICE (19,1 mm) of total adjustment from the flush pendent position. The Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, Sprinkler • A two-piece Style 20 (1/2 in. NPT) and Recessed Pendent Sprinklers or Style 30 (3/4 in. NPT) Recessed described herein must be installed Identification Escutcheon with 1/4 in. (6,4 mm) of and maintained in compliance with recessed adjustment or up to 1/2 in. this document and with the applicable Number (SIN) (12,7 mm) of total adjustment from standards of the National Fire Protec- the flush pendent position. tion Association (NFPA), in addition to TY1131 . . .Upright 2.8K, 1/2 in. NPT The adjustment provided by the the standards of any authorities having TY1231.. Pendent 2.8K, 1/2 in. NPT Recessed Escutcheon reduces the jurisdiction. Failure to do so may impair TY2131...Upright 4.2K, 1/2 in. NPT accuracy to which the fixed pipe drops the performance of these devices. TY2231.. Pendent 4.2K, 1/2 in. NPT to the sprinklers must be cut. The owner is responsible for maintain- TY3131... Upright 5.6K, 1/2 in. NPT Corrosion-resistant coatings, where ing their fire protection system and TY3231.. Pendent 5.6K, 1/2 in. NPT applicable, are utilized to extend the devices in proper operating condition. TY4131...Upright 8.0K, 3/4 in. NPT life of copper alloy sprinklers beyond The installing contractor or sprinkler TY4231.. Pendent 8.0K, 3/4 in. NPT what would be obtained when exposed manufacturer should be contacted with any questions. TY4831... Upright 8.0K, 1/2 in. NPT TY4931.. Pendent 8.0K, 1/2 in. NPT IMPORTANT NFPA 13 prohibits installation of 1/2 in. Refer to Technical Data Sheet NPT sprinklers with K-factors greater Technical TFP2300 for warnings pertaining to than 5.6 in new construction. They are regulatory and health information. intended for retrofit in existing sprinkler Data systems only. Always refer to Technical Data Approvals Sheet TFP700 for the “INSTALLER UL and C-UL Listed WARNING” that provides cautions FM, LPCB, and NYC Approved with respect to handling and instal- Refer to Table A and B for complete approval lation of sprinkler systems and com- information including corrosion-resistant ponents. Improper handling and status. installation can permanently damage a sprinkler system or its compo- Maximum Working Pressure nents and cause the sprinkler to fail Refer to Table C to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 JULY 2018 TFP171 TFP171 Page 2 of 10 * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 7 - Bushing 7 1 7/16" (11,1 mm) 3 NOMINAL 2-1/4" 2 MAKE-IN (57,2 mm) 2-3/16" 4 (55,6 mm) 1-9/16" (39,7 mm) 5 6* 1/2" NPT** WRENCH STYLE 10 or 20 2-7/8" (73,0 mm) DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 3 7/16" (11,1 mm) NOMINAL 2-3/16" 2 MAKE-IN (55,6 mm) 4 2-3/16" 1-1/2" (55,6 mm) (38,1 mm) 5 6* 1/2" NPT** WRENCH STYLE 10 or 20 2-7/8" (73,0 mm) DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 IN. NPT Discharge Coefficient Poly-Stainless K=2.8 GPM/psi½ (40,3 LPM/bar½) Physical Characteristics Design K=4.2 GPM/psi½ (60,5 LPM/bar½) Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze K=5.6 GPM/psi½ (80,6 LPM/bar½) Button ................ L316 Stainless Steel* Criteria K=8.0 GPM/psi½ (115,2 LPM/bar½) Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Glass Compression Screw . . . . . L316 Stainless Steel* The TYCO Series TY-FRB 2.8, 4.2, 5.6, Temperature Rating Deflector . . . . . . . . . . . . . . . . . . .Copper/Bronze and 8.0 K-factor Upright, Pendent, Refer to Table A and B Sealing Assembly . Gold Plated Beryllium Nickel and Recessed Pendent Sprinklers are w/TEFLON intended for fire protection systems Finishes *Type L316 stainless steel (UNS 31603) per ASTM Sprinkler: Refer to Table D A479/479M or BS EN 1008 WN1.4404. designed in accordance with the stan- dard installation rules recognized by Recessed Escutcheon: Signal or Pure White, Operation the applicable Listing or Approval Grey Aluminum, Jet Black, Chrome Plated, or Natural Brass agency, such as UL Listing based on The glass bulb contains a fluid that the requirements of NFPA 13 and FM Physical Characteristics expands when exposed to heat. When Approval based on the requirements Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze the rated temperature is reached, the of the FM Global Loss Prevention Data Button . . . . . . . . . . . . . . . . . . . . . .Brass/Copper fluid expands sufficiently to shatter the Sheets. Use only the style 10, 20, 30, or Sealing Assembly ..Beryllium Nickel w/TEFLON glass bulb, allowing the sprinkler to 40 Recessed Escutcheon, as applica- Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Glass activate and water to flow. Compression Screw . . . . . . . . . . . . . . . . .Bronze ble, for recessed pendent installations. Deflector . . . . . . . . . . . . . . . . . . .Copper/Bronze Bushing (K=2.8) . . . . . . . . . . . . . . . . . . . .Bronze TFP171 Page 3 of 10 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on 2 - Button Assembly Screw ESCUTCHEON Deflector. special request. 4 - Bulb 6 - Deflector* PLATE SEATING SURFACE 1 7/16" 3 (11,1 mm) NOMINAL 2 2-3/16" MAKE-IN (55,6 mm) 4 2-3/16" 1-1/2" (55,6 mm) (38,1 mm) 5 6* 1/2" NPT** WRENCH STYLE 10 or 20 2-7/8" (73,0 mm) DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. 1 7/16" 3 (11,1 mm) NOMINAL 2 2-3/16" MAKE-IN (55,6 mm) 4 2-3/16" 1-1/2" (55,6 mm) (38,1 mm) 5 6* STYLE 10 2-7/8" (73,0 mm) DIA. RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 IN. NPT Installation of the sprinkler. Do not attempt to com- Series TY-FRB Recessed Pendent pensate for insufficient adjustment in Sprinklers the escutcheon plate by under- or over- The Series TY-FRB Recessed Pendent The TYCO Series TY-FRB 2.8, 4.2, 5.6, tightening the sprinkler. Re-adjust the Sprinklers must be installed in accor- and 8.0 K-factor Upright, Pendent, and position of the sprinkler fitting to suit. dance with the following instructions: Recessed Pendent Sprinklers must be installed in accordance with this Series TY-FRB Upright and Pendent Step 1. After installing the Style 10, 20, section. Sprinklers 30, or 40 Mounting Plate, as applica- The Series TY-FRB Upright and ble, over the sprinkler threads and with General Instructions Pendent Sprinklers must be installed pipe-thread sealant applied to the pipe Do not install any bulb type sprinkler in accordance with the following threads, hand-tighten the sprinkler into if the bulb is cracked or there is a loss instructions: the sprinkler fitting. of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble Step 1. Install pendent sprinklers in the Step 2. Tighten the sprinkler into the should be present. The diameter of the pendent position. Install upright sprin- sprinkler fitting using only the W-Type air bubble is approximately 1/16 in. klers in the upright position. 7 Recessed Sprinkler Wrench (Ref. (1,6 mm) for the 135°F (57°C) and Figure 15). With reference to Figure 1 to Step 2. With pipe thread sealant 3/32 in. (2,4 mm) for the 286°F (141°C) 4, apply the W-Type 7 Recessed Sprin- applied to the pipe threads, hand- temperature ratings. A leak-tight 1/2 in. kler Wrench to the sprinkler wrench tighten the sprinkler into the sprinkler NPT sprinkler joint should be obtained flats. fitting. by applying a minimum-to-maximum Step 3. After the ceiling is installed or torque of 7 to 14 lb-ft (9,5 to 19,0 N·m). Step 3. Tighten the sprinkler into the the finish coat is applied, slide on the A leak tight 3/4 in. NPT sprinkler joint sprinkler fitting using only the W-Type 6 Style 10, 20, 30, or 40 Closure over should be obtained with a torque of Sprinkler Wrench (Ref. Figure 14). With the Series TY-FRB Recessed Pendent 10 to 20 lb-ft (13,4 to 26,8 N·m). Higher reference to Figure 1 to Figure 5, apply Sprinkler and push the Closure over the levels of torque can distort the sprinkler the W-Type 6 Sprinkler Wrench to the Mounting Plate until its flange comes in inlet and cause leakage or impairment sprinkler wrench flats. contact with the ceiling. TFP171 Page 4 of 10 * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 1/2" 3 (12,7 mm) NOMINAL 2-5/16" 2 MAKE-IN (58,7 mm) 2-1/4" 4 1-9/16" (57,2 mm) (39,7 mm) 5 6* 3/4" NPT** WRENCH STYLE 30 or 40 2-7/8" (73,0 mm) DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. 1 1/2" 3 (12,7 mm) NOMINAL 2 MAKE-IN 2-5/16" (58,7 mm) 4 2-1/4" 1-9/16" (57,2 mm) (39,7 mm) 5 6* STYLE 40 2-7/8" (73,0 mm) DIA. RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 IN. NPT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 - Deflector * Assembly 4 - Bulb 3 7/16" 2-1/4" (11,1 mm) (57,2 mm) 2 NOMINAL MAKE-IN * Temperature rating is 4 indicated on Deflector. 2-3/16" 1-9/16" (55,6 mm) (39,7 mm) 5 ** Pipe thread connections per ISO 7-1 can be 6 * provided on special 1/2" NPT** WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 IN. NPT TFP171 Page 5 of 10 2-7/8" DIA. 2-7/8" DIA. (73,0 mm) (73,0 mm) 5/8±1/4" 3/4" (19,1 mm) 1/2±1/8" 1/2" (12,7 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) (57,2 mm) FACE OF MOUNTING FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) MOUNTING MOUNTING SURFACE SURFACE 1-5/16" (33,3 mm) 1-5/16" (33,3 mm) CLOSURE SERIES CLOSURE SERIES TY-FRB 13/16" (20,6 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 6 FIGURE 7 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 IN. NPT 2.8 K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. 2-7/8" DIA. (73,0 mm) (73,0 mm) 5/8±1/4" 3/4" (19,1 mm) 1/2±1/8" 1/2" (12,7 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) (57,2 mm) FACE OF MOUNTING FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) MOUNTING MOUNTING SURFACE SURFACE SERIES 1-1/4" (31,8 mm) SERIES 1-1/4" (31,8 mm) CLOSURE CLOSURE TY-FRB 3/4" (19,1 mm) TY-FRB 1" (25,4 mm) FIGURE 8 FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 IN. NPT 4.2 K-FACTOR, 1/2 IN. NPT TFP171 Page 6 of 10 2-7/8" DIA. 2-7/8" DIA. (73,0 mm) (73,0 mm) 5/8±1/4" 3/4" (19,1 mm) 1/2±1/8" 1/2" (12,7 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) (57,2 mm) FACE OF MOUNTING FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) MOUNTING MOUNTING SURFACE SURFACE SERIES 1-1/4" (31,8 mm) SERIES 1-1/4" (31,8 mm) CLOSURE CLOSURE TY-FRB 3/4" (19,1 mm) TY-FRB 1" (25,4 mm) FIGURE 10 FIGURE 11 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT 5.6 K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. 2-7/8" DIA. (73,0 mm) 3/4" (19,1 mm) (73,0 mm) 1/2" (12,7 mm) 5/8±1/4" 1/2±1/8" (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) (57,2 mm) FACE OF MOUNTING FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) MOUNTING MOUNTING SURFACE SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16" (20,6 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS PUSH WRENCH (END "B" USED FOR IN TO ENSURE 3/4" NPT MODELS) ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 FIGURE 15 W-TYPE 6 SPRINKLER W-TYPE 7 RECESSED WRENCH SPRINKLER WRENCH TFP171 Page 7 of 10 Sprinkler Finish5 K- Type Temperature Bulb Liquid Natural Chrome Plated Polyesterc Factor Color Brass 135°F (57°C) Orange Pendent 155°F (68°C) Red (TY1231) and 175°F (79°C) Yellow 1, 2, 3, 4 Upright (TY1131) 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange 2.8 Recessed 1/2 in. NPT Pendent 155°F (68°C) Red (TY1231)a 175°F (79°C) Yellow Figure 6 200°F (93°C) Green 1, 2, 4 135°F (57°C) Orange Recessed Pendent 155°F (68°C) Red (TY1231)b 175°F (79°C) Yellow Figure 7 200°F (93°C) Green 135°F (57°C) Orange Pendent 155°F (68°C) Red (TY2231) and 175°F (79°C) Yellow Upright (TY2131) 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange 4.2 Recessed 1/2 in. NPT Pendent 155°F (68°C) Red 1, 2 (TY2231)a 175°F (79°C) Yellow Figure 8 200°F (93°C) Green 135°F (57°C) Orange Recessed Pendent 155°F (68°C) Red (TY2231)b 175°F (79°C) Yellow Figure 9 200°F (93°C) Green NOTES a. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. b. Installed with Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. c. Frame and Deflector only. 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed, the sprinklers are UL and C-UL Listed as corrosion- resistant sprinklers. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 8 of 10 Sprinkler Finish8 K- Type Temperature Bulb Liquid Natural Chrome Polyesterc Poly-Stainlessc Lead Factor Color Brass Plated Coated 135°F (57°C) Orange Pendent 155°F (68°C) Red (TY3231) and 175°F (79°C) Yellow 1, 2, 3, 4, 5, 6, 7 1, 2 1, 2, 3, 5 Upright 200°F (93°C) Green (TY3131) 286°F (141°C) Blue 135°F (57°C) Orange Recessed 155°F (68°C) Red 5.6 1/2 in. Pendent 175°F (79°C) Yellow 1, 2, 4, 5 1, 2 N/Ad (TY3231)a NPT Figure 10 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange Recessed 155°F (68°C) Red Pendent (TY3231)b 175°F (79°C) Yellow 1, 2, 3, 4, 5 N/A N/A Figure 11 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange Pendent 155°F (68°C) Red (TY4231) and 175°F (79°C) Yellow 1, 2, 3, 4, 5, 6, 7 1, 2 1, 2, 5 Upright 200°F (93°C) Green (TY4131) 286°F (141°C) Blue 135°F (57°C) Orange Recessed 155°F (68°C) Red 8.0 Pendent 3/4 in. (TY4231)a 175°F (79°C) Yellow 1, 2, 5 1, 2 N/A NPT Figure 12 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange Recessed 155°F (68°C) Red Pendent (TY4231)b 175°F (79°C) Yellow 1, 2, 3, 5 N/A N/A Figure 13 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange Pendent 155°F (68°C) Red 8.0 (TY4931) 1/2 in. and 175°F (79°C) Yellow 1, 2, 4, 5, 6 N/A 1, 2, 5 NPT Upright 200°F (93°C) Green (TY4831) 286°F (141°C) Blue NOTES a. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. b. Installed with Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. c. Frame and Deflector only. d. Not Available (N/A) 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 9 of 10 Sprinkler Finish K- Natural Chrome Type Polyester Lead Coated Factor Brass Plated Pendent (TY1231) and 2.8 Upright (TY1131) 1/2 in. 175 psi (12,1 bar) N/A2 NPT Recessed Pendent (TY1231) Pendent (TY2231) and 4.2 Upright (TY2131) 1/2 in. 175 psi (12,1 bar) N/A NPT Recessed Pendent (TY2231) Pendent (TY3231) and 5.6 Upright (TY3131) 250 psi (17,2 bar) 1/2 in. or 175 psi (12,1 bar)1 NPT Recessed Pendent (TY3231) Pendent (TY4231) 175 psi and (12,1 bar) 8.0 Upright (TY4131) 3/4 in. 175 psi (12,1 bar) NPT Recessed N/A Pendent(TY4231) 8.0 Pendent (TY4931) 175 psi 1/2 in. and 175 psi (12,1 bar) (12,1 bar) NPT Upright (TY4831) NOTES 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Under- writers Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. 2. Not applicable (N/A). TABLE C MAXIMUM WORKING PRESSURE Care and corrosive products of combustion, but requirements and/or national codes. have not operated, should be replaced Care must be exercised to avoid if they cannot be completely cleaned Maintenance damage to the sprinklers before, by wiping the sprinkler with a cloth or during, and after installation. Sprin- by brushing it with a soft bristle brush. The TYCO Series TY-FRB 2.8, 4.2, 5.6, klers damaged by dropping, striking, and 8.0 K-factor Upright, Pendent, and Care must be taken to avoid damage wrench twist/slippage, or the like, must Recessed Pendent Sprinklers must be to the sprinklers before, during, and be replaced. Also, replace any sprin- maintained and serviced in accordance after installation. Sprinklers damaged kler that has a cracked bulb or that has with this section. Before closing a fire by dropping, striking, wrench twist/ lost liquid from its bulb. (Ref. Installa- protection system main control valve slippage, or the like, must be replaced. tion Section). for maintenance work on the fire pro- Also, replace any sprinkler that has a Initial and frequent visual inspections of tection system that it controls, obtain cracked bulb or that has lost liquid from random samples are recommended for permission to shut down the affected its bulb. (Ref. Installation Section). corrosion-resistant sprinklers to verify fire protection systems from the proper The owner is responsible for the the integrity of the corrosion-resistant authorities and notify all personnel who inspection, testing, and maintenance of material of construction. Thereafter, may be affected by this action. their fire protection system and devices annual inspections per NFPA 25 should Absence of the outer piece of an in compliance with this document, as suffice.Inspections of corrosion-resis- escutcheon, which is used to cover well as with the applicable standards tant sprinklers are recommended at a clearance hole, can delay sprinkler of the National Fire Protection Asso- close range, instead of from the floor operation in a fire situation. ciation (e.g., NFPA 25), in addition to level per NFPA. Inspection at close the standards of any other authorities range can better determine the exact Sprinklers which are found to be having jurisdiction. Contact the install- sprinkler condition and the long-term leaking or exhibiting visible signs of ing contractor or sprinkler manufac- integrity of the corrosion-resistant corrosion must be replaced. turer regarding any questions. material, which can be affected by the Automatic sprinklers must never be corrosive conditions present. Automatic sprinkler systems are rec- painted, plated, coated, or other- ommended to be inspected, tested, wise altered after leaving the factory. and maintained by a qualified Inspec- Modified sprinklers must be replaced. tion Service in accordance with local Sprinklers that have been exposed to TFP171 Page 10 of 10 P/N 57 – XXX – X – XXX TEMPERATURE SIN SPRINKLER RATINGS FINISH 330 2.8K UPRIGHT (1/2 in. NPT) TY1131 135 135°F (57°C) 1 NATURAL BRASS 331 2.8K PENDENT (1/2 in. NPT) TY1231 155 155°F (68°C) POLY-STAINLESS GREY 2 ALUMINUM (RAL9007)1 340 4.2K UPRIGHT (1/2 in. NPT) TY2131 POLYESTER 175 175°F (79°C) PURE WHITE 3 POLYESTER (RAL9010)2 341 4.2K PENDENT (1/2 in. NPT) TY2231 200 200°F (93°C) SIGNAL WHITE 4 370 5.6K UPRIGHT (1/2 in. NPT) TY3131 POLYESTER (RAL9003) 286 286°F (141°C) JET BLACK 371 5.6K PENDENT (1/2 in. NPT) TY3231 5 POLYESTER (RAL9005)3 7 LEAD COATED 390 8.0K UPRIGHT (3/4 in. NPT) TY4131 9 CHROME PLATED 391 8.0K PENDENT (3/4 in. NPT) TY4231 360 8.0K UPRIGHT (1/2 in. NPT) TY4831 NOTES 1. Available only on TY3131, TY3231, TY4131, and TY4231 2. Eastern Hemisphere sales only. 361 8.0K PENDENT (1/2 in. NPT) TY4931 3. Available in only 2.8K, 4.2K, and 8.0K, 155°F (68°C) and 200°F (93°C); requires longer lead time to manufacture. TABLE D SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions, visit Contact your local distributor for www.tyco-fire.com. availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) temperature rating, (specify) finish or coating, P/N (specify from Table D) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 © 2018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; TEFLON is a registered trademark of DuPont BELLS PBA-AC & MBA-DC UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating * Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox These vibrating type bells are designed for use as fi re, burglar or general Notes: signaling devices. They have low power consumption and high decibel 1. Minimum dB ratings are calculated from integrated sound pressure ratings. The unit mounts on a standard 4" (101mm) square electrical box measurements made at Underwriters Laboratories as specifi ed in UL for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C). deep weatherproof backbox for outdoor applications. Weatherproof 2. Typical dB ratings are calculated from measurements made with a backbox model BBK-1, Stock No. 1500001. conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. Size inches Voltage Model Stock Current Typical dB at Minimum dB at (mm) Number Number (Max.) 10 ft. (3m) (2) 10 ft. (3m) (1) 6 (150) 12VDC MBA126 1750070 .12A 85 76 8 (200) 12VDC MBA128 1750080 .12A 90 77 10 (250) 12VDC MBA1210 1750060 .12A 92 78 6 (150) 24VDC MBA246 1750100 .06A 87 77 8 (200) 24VDC MBA248 1750110 .06A 91 79 10 (250) 24VDC MBA2410 1750090 .06A 94 80 6 (150) 24VAC PBA246 1806024* .17A 91 78 8 (200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6 (150) 120VAC PBA1206 1806120* .05A 92 83 8 (200) 120VAC PBA1208 1808120* .05A 99 84 10 (250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or BBX-1. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833• www.pottersignal.com PRINTED IN USA MFG. #5400776 - REV Y PAGE 1 OF 2 5/08 BELLS PBA-AC & MBA-DC Bells Dimensions Inches (mm) Wiring (rear view) Fig. 1 Fig. 3 A.C. BELLS 10” WHITE (IN) WHITE (OUT) (250) 8” (200) FROM CONTROL 6” PANEL OR (150) PRECEDING BELL BLACK (IN) BLACK (OUT) CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. 2 11/16” (68) NOTES: DWG# 776-1 1. WHEN USING AC BELLS, TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. DWG# 776-3 Weatherproof Backbox Dimensions Inches (mm) Fig. 2 FACP _ + Box has one threaded 1/2" conduit entrance 5 3/4” 3 3/8” 5” To Next (146) (86) (127) Device or End-of-Line Resistor 3 3/8” 1 5/8” (86) (41) 4 1/4” (108) Installation DWG# 776-2 1. The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. 2. Remove the gong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox (bell mechanism must be 4 1/4” (108)3 3/8” (85.9) mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can BBX-1 2” (51) be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG. #5400776 - REV Y PAGE 2 OF 2 5/08 Spare Sprinkler Head Storage Cabinet Description Fire Protection Products, Inc. Spare Sprinkler Head Cabinets are designed to allow for spare sprinkler head storage as required by NFPA guidelines. The Spare Sprinkler Head Cabinets are available in six configurations. Three head, six head, six head ESFR, twelve head, twenty-four head and thirty-six head. All six styles are manufactured with “knockouts” to accommodate the most common size sprinklers. The shelf is located to allow for the storage of a typical sprinkler head wrench. Each cabinet is finished with a red enamel finish. Each spare head cabinet comes with a hinged door which remains closed to protect the spare sprinklers from the elements and features two holes on the back panel to allow for attachment to most surfaces utilizing the appropriate fasteners. Not intended for exposed or harsh environments. Installation Specifications Select the correct Spare Sprinkler Head Cabinet in accordance with the Material: Automatic Sprinkler Systems Handbook. As per the 1989 Edition the correct Painted Plain Steel number of spare sprinkler is as follows: Finish: Red enamel 0-300 sprinklers, not less than 6; 300-1000, not less than 12; 1000 or more, not less than 24. Stock of spare sprinklers shall include all types and ratings Styles: installed.* 3 Spare sprinklers, 1/2 or 3/4 6 Spare sprinklers, 1/2 or 3/4 6 Spare, ESFR, 1/2, 3/4 or 1” Once the correct Spare Sprinkler Head Cabinet has been selected, installation 12 Spare sprinklers 1/2 or 3/4 is accomplished by inserting the correct fastener in each of the two holes inside 24 Spare sprinklers the cabinet, securing the cabinet securely to the wall. The insert the correct 36 Spare sprinklers number and type of sprinklers in accordance with the “handbook”. *Final determination is subject to approval by the AHJ. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 © 2012 Fire Protection Products, Inc. WWW.FPPI.COM Schedule 10 and Schedule 40 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer Bull Moose Tube’s Sch. 10 and Sch. 40 pipes are of quality pipe products. Our Schedule 10 and made to ASTM A135 and ASTM A795. These Schedule 40 are FM Approved and UL Listed (for U.S. products are typically supplied with our protective and Canada), even though these products do not coating but can be supplied without the coating so require separate approvals and listings. Bull Moose they can be hot-dip galvanized to meet FM Tube made the decision to have them approved and requirements for use in dry systems in accordance listed for your peace of mind. Our Sch. 10 and Sch. 40 with the zinc coating specifications of ASTM A795 or have been through the same rigorous testing as our ASTM A53. All Schedule 10 and Schedule 40 pipe other fine pipe products. has a pressure rating of 300 PSI. Schedule 10 Pipe Nominal Pipe Size (in) Nominal O.D. (in) Nominal I.D. (in) Weight/Ft Bundle Size 1 1.315 1.097 1.41 lbs/ft 91 1 1/4 1.660 1.442 1.81 lbs/ft 61 1 1/2 1.900 1.682 2.09 lbs/ft 61 2 2.375 2.157 2.64 lbs/ft 37 2 1/2 2.875 2.635 3.53 lbs/ft 30 3 3.500 3.260 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft 19 Schedule 40 Pipe Nominal Pipe Size (in) Nominal O.D. (in) Nominal I.D. (in) Weight/Ft Bundle Size 1 1.315 1.049 1.68 lbs/ft 70 1 1/4 1.660 1.380 2.27 lbs/ft 51 1 1/2 1.900 1.610 2.72 lbs/ft 44 2 2.375 2.067 3.66 lbs/ft 30 2 1/2 2.875 2.468 5.80 lbs/ft 30 3 3.500 3.068 7.58 lbs/ft 19 4 4.500 4.026 10.80 lbs/ft 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer’s instructions for the specific fitting used. 1819 Clarkson Road For additional information, Chesterfield, MO 63017 contact your salesperson (800) 325-4467 today at (800) 325-4467 or FAX: (636) 537-2645 (636) 537-2600 in the USA, www.bullmoosetube.com or from Canada A company e-mail: sales@bullmoosetube.com call (800) 882-4666 All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09 EDDY FLOW SPRINKLER PIPE SUBMITTAL DATA SHEET APPROVALS AND SPECIFICATIONS FINISHES AND COATINGS • ASTM A135, Grade A • Eddy Flow Sprinkler Pipe receives an OD mill coating of water-based • ASTM A795, Type E, Grade A paint which has corrosion protection expected with a painted carbon • Pressure rated to 300 psi steel product, i.e. it would be expected to resist corrosion for an • Underwriters Laboratories— extended and indefinite period in a clean and dry environment and, United States of America as environmental conditions deteriorate, the corrosion protection • Underwriters Laboratories—Canada would also diminish. • Factory Mutual • Eddy Flow Sprinkler Pipe (black) receives an ID mill coating of Eddy • NFPA-13 Guard II MIC preventative coating. EG2 has been tested at • NFPA-13R independent laboratories to resist bacterial growth and maintain minimal bacterial count after multiple flushes (25) of the pipe. • NFPA-14 • CIVIL DEFENSE APPROVAL— • Eddy Flow Sprinkler Pipe when Hot Dip Galvanized by ASTM A123 United Arab Emirates and supplied by Bull Moose Tube is UL listed and FM approved. • Made in the United States of America PRODUCT IDENTIFICATION • UL, ULC & FM listed for roll-groove, plain-end and welded joints for wet, dry, • Every length of Bull Moose fire sprinkler pipe features large, easy-to- preaction and deluge sprinkler systems. read, continuous stenciling, clearly identifying the manufacturer, type • LEED v4 Certified of pipe, size, and length. Nominal Pipe Size (inches) 1-1/4” 1-1/2” 2” 2-1/2” 3” 4” O.D. (in) 1.660 1.900 2.375 2.875 3.500 4.500 I.D. (in) 1.530 1.728 2.203 2.705 3.334 4.310 Empty Weight (lb/ft) 1.222 1.844 2.330 2.809 3.361 4.968 Water Filled Weight (lb/ft) 2.019 2.860 3.982 5.299 7.144 11.290 C.R.R.* 1.98 3.44 2.78 1.66 1.00 1.00 Pieces per Lift 61 61 37 30 19 19 *Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY SUBMITTAL INFORMATION Project Contractor Engineer Specification Reference Date System Type Locations Comments Eddy Flow - Black Eddy Flow - Hot Dip Galvanized 1819 Clarkson Road, Chesterfield, MO 63017 US: 800.325.4467 | Canada: 800.882.4666 | sales@BullMooseIndustries.com itwbuildex.com National Headquarters Customer Service 700 High Grove Blvd. 1349 W Bryn Mawr Ave Glendale Heights, IL 60139 Itasca, IL 60143 P: 630.825.7900 P: 800.848.5611 E: orders@itwccna.com Technical Support P: 800.848.5611 E: technical@itwccna.com Made in U.S.A. Sammys, Sammy X-Press, Sammy X-Press It, Sidewinder, Sammy X-Press Swivel, Sammy 2018-2019 X-Press Sidewinder, Tapcon, Sammy Saddle, Speedy Pole Tool, Spot-Rite Level, Dekite, Swivel Head, Sammys Toggle, and Teks are trademarks of Illinois Tool Works, Inc. Dektite is a registered trademark of Deks Industries Pty Ltd. © 2018 Illinois Tool Works, Inc. Product Catalog TABLE OF CONTENTS Sammys® for Wood .......................................................................................................................... 4 Sidewinder® for Wood ....................................................................................................................... 5 Sammys Swivel Head™ for Wood ......................................................................................................5 Sammys® for Steel ............................................................................................................................ 6 Sidewinder® for Steel ........................................................................................................................ 7 Sammys Swivel Head™ for Steel .......................................................................................................7 Sammy X-Press® ...............................................................................................................................8 Sammy X-Press Sidewinder™ ............................................................................................................8 Sammy X-Press Swivel™ ...................................................................................................................9 Sammy X-Press It® Installation Tool ..................................................................................................9 Sammys® for Concrete ................................................................................................................... 10 Sidewinder® for Concrete ................................................................................................................10 Sammys Swivel Head™ for Concrete ................................................................................................11 Concrete/Wood Installation Kit ........................................................................................................ 11 Sammys Toggle™ ............................................................................................................................ 12 Dektite® Pipe Flashing .....................................................................................................................12 Sammys X-Press® Pole Tool Kit ......................................................................................................13 Sammys Pole Tool™ .........................................................................................................................13 Approvals and Listings ....................................................................................................................14 Special Notes ..................................................................................................................................15 Warranty • Disclaimer of Warranty Proper fastener connection design takes in to account where and how fasteners are used. Allowance for special characteristics in materials, differences in materials, differences in types of materials being joined, unique or unusual environmental service or installation conditions and the safety factors required by anticipating normal or short term loading conditions must be considered. Due to possible differences in specifications, applications, and interpretation of results, purchasers and specifiers must make their own evaluation of the products, to determine the suitability of these products for intended use. All warranties of Buildex products, expressed or implied, including the warranties of merchantabilty and fitness for particular purposes are specifically excluded except for the following: Buildex will repair or replace any product which, within twelve months after sale by Buildex or its distributors, is found by Buildex to be defective in material or workmanship - normal wear and tear accepted. This is the sole warranty of Buildex and the sole remedy available to distributor or buyer. Buildex shall not be liable for any injury, loss or damage, direct, indirect, or consequential, arising out of the use of, or the inability to use, any Buildex product. For the most up to date information, visit www.itwbuildex.com INSTALLATION INSTRUCTIONS FOR WOOD & STEEL INSTALLATION STEPS - VERTICAL INTO WOOD & STEEL: INSTALLATION STEPS - HORIZONTAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS® into the #14 (black) nut driver (p/n 8113910). Drill 2. Insert the SAMMYS into the #14SW (red) nut driver (p/n 8114910). With drill should be in a vertical position. unit in a horizontal position and at a right angle to the structural member, begin installation. 3. Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. 3. When the nut driver spins freely on the SAMMYS, stop the drill and remove. 4. The SAMMYS is now ready to receive 1/4”, 3/8”, 1/2” or metric all thread rod, bolt stock. (The 1/2” requires the #14SW red nut driver) 4. The unit is now ready to receive 1/4”, 3/8”, M10, M8 or metric all thread rod or bolt stock. Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 inch lbs. for maximumpullout in purlin steel. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 inch lbs. for maximum pullout in purlin steel. INSTALLATION INSTRUCTIONS FOR CONCRETE INSTALLATION STEPS - VERTICAL INTO CONCRETE: INSTALLATION STEPS - HORIZONTAL INTO CONCRETE: 1. Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 1. Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2” with a carbide tip bit, pre-drill the concrete member to a depth of 2” with a hammer/ hammer/rotary hammer drill set on impact mode. rotary hammer drill set on impact mode. 2. After pre-drilling has been completed, install the SLEEVE TOOL over 2. After pre-drilling has been completed, install the SLEEVE TOOL the bit (the bit should remain in the drill), and insert the #14 (black) over the bit (the bit should remain in the drill), and insert the #14SW (red) nut driver (p/n 8113910) into the opposite end (see Vertical Installation nut driver (p/n 8114910) into the opposite end. note above). 3. Insert the SWC screw into the nut driver. 3. Insert the CST screw into the nut driver. 4. Place tip of screw into the pre-drilled hole, turn impact/drill unit to 4. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill drill mode and begin insertion. When the nut driver spins free on the mode and begin insertion. When the nut driver spins freely on the SWC screw, installation is complete. Stop and remove drill. CST screw, installation is complete. Stop and remove drill. 5. The SWC screw is ready to receive 1/4”, 3/8” or metric all thread rod 5. The concrete screw is ready to receive 1/4”, 3/8”, 1/2”, or metric all or bolt stock. thread rod or bolt stock. (#14SW red nut driver used with 1/2” screw) Note: Use a 1200 maximum RPM drill for installation. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode — Note: Do not install concrete screws while the drill unit is in impact mode — doing so will destroy the pullout factor of the fastener. doing so will destroy the pullout factor of the screw. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. 3 To find a distributor near you, call 800-848-5611 SAMMYS® FOR WOOD SAMMYS® FOR WOOD - Vertical Application Application Product Features Not less than 2” nominal width Wood Flooring • No pre-drilling required. (1-1/2”) • Quick to install using the Sammy Not less than Nut Driver with an 18V cordless 3” nominal drill. thickness (2-1/2”) (depth or side Wood Joist • Saves time from traditional of vertical member) methods. Double Sheetrock For vertical use - Ceiling • Reduces installation costs. install in center of lower face. • Assembled in the U.S.A. Minimum 2” embedment into base material for NFPA 13 compliance. Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for GST 25-380 . Tool available on page 11. View our installation videos! Rod Part Screw Ultimate UL Test FM Test Box Case Approvals Model Size Number Descriptions Pullout (lbs) Load (lbs) Load (lbs) Qty Qty VERTICAL MOUNT 210 (7/16” OSB) 1/4" 8002957 GST 100 1/4 x 1" 25 125 670 (3/4” Ply) 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 210 (7/16” OSB) 3/8" 8007957 GST 10 1/4 x 1" 300 25 125 670 (3/4” Ply) 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 #14 Black 3/8" 8068925 GST 20-SS 1/4 x 2" 1760 (Fir) 850 25 125 Nut Driver 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 Part # 8113910 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 #14 SW Red Nut Driver Part # 8114910 ASSEMBLED U.S.A. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the most up to date information, visit www.itwbuildex.com 4 SIDEWINDER® FOR WOOD - Horizontal Application WOOD Application Product Features Not less than 2” nominal width • No pre-drilling required. (1-1/2”) up to 3-1/2” pipe; not less than 3” (2-1/2”) nominal width 4” & 5” pipe • Quick to install using the Sammy Floor Joist Nut Driver with an 18V cordless drill/driver. Minimum 2-1/2” from bottom for branch lines. Minimum 3” from bot- tom for main lines. Exception: This • Saves time from traditional requirement shall not apply to 2” or methods. thicker nailing strips resting on top of steel beams. • Reduces installation costs. STEEL • Assembled in the U.S.A. Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for Model SWG 25-380. Tool available on page 11. View our installation videos! Rod Part Screw Ultimate UL Test Box Case Approvals Model STEEL Size Number Descriptions Shear (lbs) Load (lbs) Qty Qty HORIZONTAL MOUNT 3/8" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 125 3/8" 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 3/8" 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 3/8"* 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 #14 SW Red Nut Driver Part # 8114910 SAMMYS SWIVEL HEAD™ FOR WOOD - Swivel Application Application Product Features CONCRETE • Eliminates distortion of threaded rod. • Accommodates up to 3 ½” x 12 pitch roof. • Allows 17° deflection from vertical. • Saves time from traditional methods. • Reduces installation costs. • Assembled in the U.S.A. Rod Part Screw Ultimate UL Test Load FM Test Min Box Case Approvals Model Size Number Descriptions Pullout (lbs) (lbs) Load (lbs) Thickness Qty Qty SWIVEL MOUNT #14 Black Nut Driver 3/8" 8139957 SH-GST 20 1/4 x 2" 1257 (Fir) 1050 1475 25 125 ACCESSORIES Part # 8113910 1903 Dim. Lumber 1500 3/8"* 8269957 SH-GST/CST 20 5/16 x 1-3/4” 1406 @ 45°off vertical 25 125 850 @ 45° Dim. Lumber * May require pre-drilling; consult joist manufacturer. #14 SH Orange ** Will not swivel until installed with black nut driver. Nut Driver Part # 8273910 APPROVALS 5 To find a distributor near you, call 800-848-5611 SAMMYS® FOR STEEL SAMMYS® FOR STEEL - Vertical Application Application Product Features • Made with Teks® self-drilling fasteners - no pre-drilling required. • Installs into steel range from 20 gauge – 1/2” thicknesses. • Saves time from traditional methods. • Reduces installation costs. • Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. • A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. • Assembled in the U.S.A. View our installation videos! Rod Part Screw Ultimate UL Test FM Test Min Max Box Case Approvals Model Size Number Descriptions Pullout (lbs) Load (lbs) Load (lbs) Thick Thick Qty Qty VERTICAL MOUNT 1/4" 8024957 DSTR 100 * 1/4-20 x 1" TEKS 3 1510 (20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8025957 DST 100 1/4-14 x 1" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8026957 DST 150 1/4-14 x 1-1/2" TEKS 3 970 (16 ga.) .036"-20 ga 3/16" 25 125 1/4" 8027957 DST 200 1/4-14 x 2" TEKS 3 446 (20 ga.) .036”-20 ga 3/16” 25 125 3/8" 8038957 DSTR 1 * 1/4-20 x 1" TEKS 3 1510 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 3/8" 8037957 DSTR 1-1/2 * 12-24 x 1-1/2" TEKS 5 1510 (3/16") 1500 1475 .060”-16 ga. 1/2" 25 125 3/8" 8039957 DSTR 516 * 5/16-18 x 1-1/4" TEKS 3 2200 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 446 (20 ga.) 3/8" 8040957 DST 10 1/4-14 x 1" TEKS 3 .036"-20 ga 3/16" 25 125 970 (16 ga.) 446 (20 ga.) 3/8" 8041957 DST 15 1/4-14 x 1-1/2" TEKS 3 .036"-20 ga 3/16" 25 125 970 (16 ga.) 446 (20 ga.) 3/8" 8044957 DST 30 1/4-14 x 3" TEKS 3 .036"-20 ga 3/16" 25 125 970 (16 ga.) #14 Black 3/8" 8045957 DST 516 5/16-18 x 1-1/4" TEKS 3 1500 (3/16") 1500 1475 .125"-1/8" 3/16" 25 125 Nut Driver 3/8" 8046957 TEK 50 12-24 x 1-1/2" TEKS 5 3125 (3/16") 1500 1475 .250”-1/4” 1/2" 25 125 Part # 8113910 446 (20 ga.) 1/2" 8031925 DST 2.0 1/4-14 x 2" TEKS 3 .188"-3/16" 1/4" 25 125 970 (16 ga.) 1/2" 8036925 TEK 5.0 12-24 x 1-1/2" TEKS 5 3125 (3/16") .188"-3/16" 1/2" 25 125 *Includes retaining nut #14 SW Red Nut Driver Part # 8114910 ASSEMBLED U.S.A. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the most up to date information, visit www.itwbuildex.com 6 SIDEWINDER® FOR STEEL - Horizontal Application WOOD Application Product Features • Made with Teks® self-drilling fasteners - no pre-drilling required. • Installs into steel range from 20 gauge – 1/2” thicknesses. • A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. • Saves time from traditional methods. • Reduces installation costs. • Quick to install using the Sammys Nut Driver with an View our 18V cordless drill/driver. installation videos! • Asembled in the U.S.A. STEEL Rod Part Screw Ultimate UL Test FM Test Min Max Box Case Approvals Model Size Number Descriptions Shear (lbs) Load (lbs) Load (lbs) Thickness Thickness Qty Qty HORIZONTAL MOUNT 3/8" 8050957 SWD 10 1/4-14 x 1" TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 3/8” 8052957 SWD 20 1/4-14 x 2” TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 3/8" 8055957 SWDR 1 * 1/4-20 x 1" TEKS 3 1900 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 3/8" 8054957 SWDR 1-1/2 * 12-24 x 1-1/2" TEKS 5 2375 (3/16") 1500 1475 .188"-3/16" 1/2" 25 125 3/8" 8056957 SWDR 516 * 5/16-18 x 1-1/4" TEKS 3 2480 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 *Includes retaining nut #14 SW Red Nut Driver STEEL Part # 8114910 SAMMYS SWIVEL HEAD™ FOR STEEL - Swivel Application Application Product Features • Eliminates distortion of threaded rod in sloped roof applications. • Accommodates 3-1/2 x 12 pitch. CONCRETE • Installs into angled z-purlin; allows threaded rod to hang plumb. • Allows 17° deflection from vertical. • Asembled in the U.S.A. View our installation videos! Rod Part Screw Ultimate UL Test FM Test Min Max Box Case Approvals Model Size Number Descriptions Pullout (lbs) Load (lbs) Load (lbs) Thick Thick Qty Qty SWIVEL MOUNT #14 Black 1/4-20 X 1” Nut Driver 3/8" 8137957 SH-DSTR 1* 3220 (3/16”) 1500 1475 .035” 3/16” 25 125 TEKS 3 ACCESSORIES Part # 8113910 2368 (1/2" steel Vertical) 12-24 x 1-5/8" 1306 (45° off Vertical) 1500 (Vertical) 4" 3/8" 8268957 SH-TEK 50 3/16" 1/2" 25 125 TEKS 5 2281 (3/16” HSS) 850 (45° off Vertical) 2-1/2” 1585 (3/16” HSS 45° off Vertical) *Does not comply with ROHS requirements / Includes retaining nut #14 SH Orange Nut Driver Part # 8273910 APPROVALS 7 To find a distributor near you, call 800-848-5611 SAMMY X-PRESS® Installs into Metal Deck, Purlin, or Tubular Steel SAMMY X-PRESS® - Vertical Application Application Product Features • The Sammy X-Press expands to provide • Less jobsite material needed. direct vertical attachment in: (XP) - light gauge steel deck or purlin • No retaining nut required. (22 ga. - 1/8”). • Provides design flexibility. • Installs in seconds with Sammy X-Press It® Tool, saving time & installation costs. • Assembledin the U.S.A. • Use in applications where access to the back of View our the installed fastener is prohibited. ie. metal roof installation videos! deck, tubular steel, or vapor barrier fabric. Rod Part Ultimate UL Test UL Min FM Test FM Min Max Box Case Approvals Model Description Application Size Number Pullout (lbs) Load (lbs) Thick Load (lbs) Thick Thick Qty Qty VERTICAL MOUNT Sammy 185 (Luminaire) .027" 1/4" 8181922 XP 200 1146 (22 ga) .125” 25 125 Metal Deck X-Press 200 250 (Luminaire) .056” 850 (2½" Pipe) .027" 940 (2" Pipe) .029” Sammy 185 (Luminaire) .027” 3/8" 8150922 XP 20 1146 (22 ga) 1475 (4” Pipe) .104” .125” 25 125 Metal Deck X-Press 20 250 (Luminaire) .056” 283 (Conduit & Cable) .029” 1500 (4" Pipe) .060” Sammy 185 (Luminaire) .029” 940 (2" Pipe) .029” 3/8" 8153922 XP 35 1783 (16 ga) .125” 25 125 Purlin X-Press 35 250 (Luminaire) .056” 1475 (4” Pipe) .104” 416 (Conduit & Cable) .059” Metal Deck Pre-Pour Structural Concrete@ 3000 psi Sammy (Pre-Pour) 3/8" 8150922 XP 20 1146 (22 ga) 850 (2½ Pipe) 25 125 X-Press 20 Metal Deck Post-Pour Range II LWC≤ 35 PCF (lbs/ft³) (Post-Pour) Pre-Pour Structural Concrete @ 3000 psi Post-Pour Range II LWC≤ 35 PCF (lbs/ ft³) SAMMY X-PRESS SIDEWINDER™ - Horizontal Application Application Product Features • The Sammy X-Press Sidewinder expands to • Less jobsite material needed. provide horizontal attachment in: - 16 ga - 3/16” steel - purlin, tubular steel. • No retaining nut required. • Installs in seconds with Sammy X-Press It® Tool, • Provides design flexibility. saving time & installation costs. • Assembled in U.S.A. of • Use in applications where access to the back of Canadian Steel the installed fastener is prohibited; ie. metal roof View our deck, tubular steel, or vapor barrier fabric. installation videos! Rod Part Ultimate UL Test UL Min FM Test Max Box Case Approvals Model Description Application Size Number Shear (lbs) Load (lbs) Thick Load (lbs) Thick Qty Qty HORIZONTAL MOUNT 1250 (3½" Pipe) Sidewinder Metal Deck/ 3/8" 8293957 SWXP 35 1798 (16 ga) 80 (Luminaire) .059” .125” 25 125 X-Press 35 Purlin 416 (Conduit & Cable) ASSEMBLED U.S.A. For the most up to date information, visit www.itwbuildex.com 8 Installs into Metal Deck, Purlin, or Tubular Steel WOOD SAMMY X-PRESS SWIVEL™ - Swivel Application Application Product Features • Less jobsite material needed. • The Sammy X-Press Swivel allows you • Less jobsite material needed. to hang plumb in extreme roof pitches: • No retaining nut required. - 89° in z-purlin • No retaining nut required. - 45° in metal deck for 12/12 pitch • Provides design flexibility. • Provides design flexibility. • Installs in seconds with Sammy X-Press It® Tool, • Assembledin the U.S.A. saving time & installation costs. • Assembled in the U.S.A. • Use in applications where access to the back of View our View our STEEL the installed fastener is prohibited. ie. metal roof installation videos! installation videos! deck, tubular steel, or vapor barrier fabric. Rod Part Ultimate UL Test UL Min FM Test FM Min Max Box Case Approvals Model Description Application Size Number Pullout (lbs) Load (lbs) Thick Load (lbs) Thick Thick Qty Qty SWIVEL MOUNT 750 (2” Pipe) 170 Vertical (Luminaire) Swivel 1061 (22 ga Vert) Metal Deck/ 3/8” 8294922 SXP 20 80 @ 45° (Luminaire) .029” 635 (2” Pipe) .029” .125” 25 125 X-Press 20 829 (45° Off Vert) Purlin 283 Vertical (Conduit & Cable) 233 @ 45° (Conduit & Cable) 1250 (3-1/2" Pipe) 250 Vertical (Luminaire) Swivel 1675 (16 ga Vert) Metal Deck/ STEEL 3/8" 8295922 SXP 35 80 @ 90° (Luminaire) .059” .029” .125” 25 125 X-Press 35 1558 (89° Off Vert) 635 (2" Pipe) Purlin 500 Vertical (Conduit & Cable) 333 @ 89° (Conduit & Cable) Swivel 1061 (22 ga Vert) Metal Deck/ 1/2” 8272957 SXP 2.0 .027” .125” 25 125 X-Press 2.0 829 (45° Off Vert) Purlin Swivel 1675 (16 ga Vert) Metal Deck/ 1/2" 8271957 SXP 3.5 .125” 25 125 X-Press 3.5 1558 (89° Off Vert) .060" Purlin SAMMY X-PRESS IT® Installation Tool CONCRETE Application Product Features Metal Deck - XPress • Less jobsite material needed. • The Sammy X-Press expands to provide direct vertical attachment in: • No retaining nut required. - metal deck (22-16 gauge) - z-purlin (18-16 gauge) • Provides design flexibility. Vertical • Assembled in the U.S.A. • Assembled in U.S.A. of View our Canadian Steel installation videos! View our installation videos! ACCESSORIES Part Number Model Description Qty 8194910 UXPIT* Universal X-Press It Tool 1 8152910 XPDB 25/64" Drill Bit 1 *Tool Includes: Sleeve, Bit Receiver, Hex Wrench, and 25/64” Drill Bit. Horizontal APPROVALS 9 To find a distributor near you, call 800-848-5611 Swivel SAMMYS® FOR CONCRETE SAMMYS® FOR CONCRETE - Vertical Application Application Product Features • Easy two step process (Drill hole & drive Sammys concrete anchor). • ¼” pre-drilled pilot hole required. • Concrete Installation Tool available for a one tool installation process. • Assembled in the U.S.A. View our installation videos! Rod Part Screw Ultimate FM Test Box Case Approvals Model Size Number Descriptions Pullout (lbs)* Load (lbs) Qty Qty VERTICAL MOUNT #14 Black 1/4" 8058957 CST 200 5/16 x 1-3/4" 2400 25 125 Nut Driver 3/8" 8059957 CST 20 5/16 x 1-3/4" 2400 1475 25 125 Part # 8113910 1/2" 8060925 CST 2 5/16 x 1-3/4" 2400 25 125 #14SW Red Nut Driver ICC-ESR 3/8” 8306957 CCST 516 5/16-14 x 2-1/2” 857** 25 125 Part # 8114910 3699+FM For complete performance data see ICC Report ESR-3699 * Tested in 3000 PSI concrete ** Pullout strength for Cracked Concrete and Seismic Zones A-F SIDEWINDER® FOR CONCRETE - Horizontal Application Application Product Features • Easy two step process (Drill hole & drive Sammys concrete anchor). • ¼” pre-drilled pilot hole required. • Concrete Installation Tool available for a one tool installation process. • Assembleded in the U.S.A. View our installation videos! Rod Part Screw Ultimate FM Test Box Case Approvals Model Size Number Descriptions Shear (lbs)* Load (lbs) Qty Qty HORIZONTAL MOUNT 3/8" 8061957 SWC 20 5/16 x 1-3/4" 2450 1475 25 125 ICC-ESR 3699+FM 3/8” 8307957 SW-CCST 516 5/16-14 x 2-1/2” 857** 25 125 #14SW Red * Tested in 3000 PSI concrete ** Pullout strength for cracked concrete and Seismic Zones A-F Nut Driver Part # 8114910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins ASSEMBLED U.S.A. free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the most up to date information, visit www.itwbuildex.com 10 SAMMYS SWIVEL HEAD™ FOR CONCRETE - Swivel Application WOOD Application Product Features • Installs vertically and swivels up to 89° in wood & concrete structures. • Eliminates distortion of threaded rod. • 1/4” pre-drilled pilot hole required. • Concrete installation tool available for a one piece installation process. STEEL • Assembled in the U.S.A. Rod Part Screw Ultimate Box Case Approvals Model Size Number Descriptions Shear (lbs)* Qty Qty SWIVEL MOUNT 2537 in 3000 psi concrete 3/8" 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1459 @ 45°off vertical in 3000 psi concrete 25 125 2852 in 6000 psi concrete 1636 @ 45°off vertical in 6000 psi concrete 3/8” 8308957 SH-CCST 516 5/16-14 x 2-1/2” 857** 25 125 STEEL Note: UL Listed for wood - see page 5 #14 SH Orange Nut Driver Part # 8273910 * Tested in 3000 PSI concrete ** Pullout strength for cracked concrete and Seismic Zones A-F CONCRETE / WOOD INSTALLATION KIT Application Rotary Hammer Drill into concrete Hammer Drill into concrete CONCRETE (b) (b) (g) (d) (h) (e) (h) or or (c) (c) (a) Part Number Description Each Qty 8122910 Concrete Installation Kit (a) 1 Kit includes the following items: 8113910 #14 Black Nut Driver (b) 1 8114910 #14 SW Red Nut Driver (c) 1 8116910c #250 Bit (1/4") (d) 1 ACCESSORIES 8117910 SDS Bit (1/4") (e) 1 8118910 7/32 Wood Bit (f) 1 8120910 HEX 250 Bit Receiver (1/4") (g) 1 8098910 SL 250 Sleeve (h) 1 APPROVALS 11 To find a distributor near you, call 800-848-5611 ACCESSORIES SAMMYS TOGGLE™ Application Installation Steps 1. Pre-drill a 5/8” hole with a regular drill or hole saw. 2. Insert SST screw into #14 black nut driver. With wing nut and washer on bolt, insert wing nut through surface, and begin installation. 3. When bolt is secure and nut driver spins free, stop drill motor and remove. Pre-Cast Hollow Core 4. SST screw is now ready to receive 1/4”, 3/8”, or Metric all Concrete thread rod or bolt stock. Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) Box Qty Case Qty 450 (Lath & Plaster) 3/8" 8064925 SST 30 1/4 x 3" 25 125 404 (2 Layers 5/8 Rock) #14 Black Nut Driver Part # 8113910 DEKTITE® PIPE FLASHING ApplicationApplication Product FeaturesProduct Features • Complies with NFPA 13 Code Changes. • Flashing for dry pendant sprinklers subject to extreme temperature changes. • One piece construction is easy to install. • Pipe diameter markings ensure accurate fit. • EPDM temperature range of -65°F to +250°F. Part Number Description Pipe Outside Diameter Dektite Base Diameter Dektite Height Box Qty 4003910 1 1/4” - 2” 4-3/4” 3” 10 4004910 2 1-3/4” - 3-1/4” 6-1/4” 4” 10 For the most up to date information, visit www.itwbuildex.com 12 SAMMY X-PRESS POLE TOOL KIT™ WOOD Application Product Features • Speed your labor by 25% • Work from the ground up • No scaffolding, ladders, or lifts • Perfect for working in tight spaces, through ceiling grid, and high vaulted ceilings • Works with any Sammy X-Press product For use installing Sammy X-Press anchors from the ground up! View our installation videos! STEEL Part Number Model Description Box Qty XPKIT* XPKIT Sammy X-Press Pole Tool Kit 1 * 3/4” electrical conduit needed for pole tool assembly STEEL SAMMYS POLE TOOL™ Installation Instructions Product Features • Speed your labor by 25% 1 2 3 • Work from the ground up Insert adjusting pin here • No scaffolding, ladders, or lifts • Perfect for working in tight spaces, through ceiling grid, and high vaulted ceilings Adjust the Pole Tool to length. Load rod and Sammys into The socket will spin free The adjusting pin must be 18” Pole Tool. when the screw is completely below the base or the pin may installed. Pull down to remove • Works with any Vertical SAMMYS: Wood, Steel, or interfere with the rod. the Pole Tool. Concrete CONCRETE Part Number Description Box Qty SP6 Speedy Pole 6’-18’ 1 ACCESSORIES APPROVALS 13 To find a distributor near you, call 800-848-5611 APPROVALS Part Mount UL Max UL Test UL Min Wood FM Max FM Test FM Min Wood Model Rod Size Number Direction Pipe Size Load (lbs) Thickness Pipe Size Load (lbs) Thickness SAMMYS FOR WOOD - PIPE HANGER 8007957 GST 10 3/8” Vertical CPVC 1-1/2” 300 1-1/2” 8020957 SWG 10 3/8” Horizontal CPVC 1-1/2” 300 1-1/2” 8008957 GST 20 3/8” Vertical 2-1/2” 850 1-1/2” 4” 1475 1-1/2” 8068925 GST 20-SS 3/8” Vertical 2-1/2” 850 1-1/2” 8010957 GST 30 3/8” Vertical 4” 1500 1-1/2” 4” 1475 1-1/2” 8009925 GST 25-380 3/8” Vertical 4” 1500 1-1/2” 8022925 SWG 25-380 3/8” Horizontal 3-1/2” - 4”* 1500 1-1/2” 8021957 SWG 20 3/8” Horizontal 2-1/2” - 3”** 1050 1-1/2” 8073925 SWG 20-SS 3/8” Horizontal 2-1/2” 850 1-1/2” 8269957 SH-GST/CST 20 3/8” 45° Angle off Vertical 2-1/2” 850 1-1/2” 8269957 SH-GST/CST 20 3/8” 45° Angle off Vertical 4” 1500 1-1/2” 8139957 SH-GST 20 3/8” 17° Angle off Vertical 3” 1050 1-1/2” 4” 1475 1-1/2” SAMMYS FOR STEEL - PIPE HANGER Min Steel Thick Max Steel Thick 8038957 DSTR 1 3/8” Vertical 4” 1500 .035” 4” 1475 .105” 8037957 DSTR 1-1/2 3/8” Vertical 4” 1500 .035” 4” 1475 .105” 8039957 DSTR 516 3/8” Vertical 4” 1500 .037” 4” 1475 .105” 8045957 DST 516 3/8” Vertical 4” 1500 .188” 4” 1475 .188” 8046957 TEK 50 3/8” Vertical 4” 1500 .250” 4” 1475 .188” 8055957 SWDR 1 3/8” Horizontal 4” 1500 .037” 4” 1475 .060” 8056957 SWDR 516 3/8” Horizontal 4” 1500 .037” 4” 1475 .060” 8054957 SWDR 1-1/2 3/8” Horizontal 4” 1500 .037” 4” 1475 .060” 8137957 SH-DSTR 1 3/8” 17° Angle off Vertical 4” 1500 .035” 4” 1475 .105” Vertical 2-1/2” 850 8268957 SH-TEK 50 3/8” 70° Angle off Vertical 4” 1500 2” 940 .029” 8150922 XP 20 3/8” Vertical 2-1/2” 850 .027” 4” 1475 .105” 2” 940 .029” 8153922 XP 35 3/8” Vertical 4” 1500 .060” 4” 1475 .125” 8294922 SXP 20 3/8” Vertical or up to 45° 2” 750 .027” 2” 635 .029” 8295922 SXP 35 3/8” Vertical or up to 89° 3-1/2” 1250 .060” 2” 635 .029” 8293957 SWXP 35 3/8” Horizontal 3-1/2” 1250 .060” SAMMYS FOR CONCRETE - PIPE HANGER 8059957 CST 20 3/8” Vertical 4” 1475 3000 8061957 SWC 20 3/8” Horizontal 4” 1475 3000 8150922 XP 20 3/8” Vertical 2-1/2” 850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8” Vertical 2-1/2” 850 Post-Pour Range II LWC ≤ 35 PCF (lbs/ft3) Part Rod Mount UL Load UL Min Steel Model Number Size Direction Rating (lbs) Thickness SAMMYS FOR STEEL - LUMINAIRE FITTING 185 .027” 8150922 XP 20 3/8” Vertical 250 .035” 185 .027” 8153922 XP 35 3/8” Vertical 250 .035” 185 .027” 8181922 XP 200 1/4” Vertical 250 .035” Vertical 170 .027” 8294922 SXP 20 3/8” 45° 80 .027” Vertical 250 .060” 8295922 SXP 35 3/8” 90° 80 .060” 8293957 SWXP 35 3/8” Horizontal 80 .060” Part Rod Mount UL Load UL Min. Steel Model Listed Application Number Size Direction Rating (lbs) Thickness SAMMYS FOR STEEL - CONDUIT, TUBING, AND CABLE 8150922 XP 20 3/8” Vertical 283 .027” Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8” Vertical 500 .060” Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8” Vertical 283 .027” Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8” Vertical 500 .060” Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8” Horizontal 500 .060” Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit UL Listed 4S16 - Cable Hanger, Cat. No. C-Z2000 Plenum Rated, 8149957 CZ2000 1/4” or 3/8” Onto Vertical Rod Complies w/ NEC Standards Sheet Steel Gauges Gauge No. 22 ga. 20 ga. 18 ga. 16 ga. 14 ga. 12 ga. 1/8” 3/16” 1/4” Nominal Decimal Equivalent .030” .036” .048” .060” .075” .105” .125” .188” .250” *SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2” UL compliance with NEC Standards. *SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4” UL and FM tests were performed in compliance with NFPA 13 Standards. **SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2” Fastening requirement: 5 times weight of water-filled schedule 40 pipe plus 250 pounds. **SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3” For the most up to date information, visit www.itwbuildex.com 14 SPECIAL NOTES Part Mount UL Max UL Test UL Min Wood FM Max FM Test FM Min Wood Engineering Note Model Rod Size Number Direction Pipe Size Load (lbs) Thickness Pipe Size Load (lbs) Thickness In 1996, the anchors listed by UL were tested in plate steel that measured .188” and .118”. Subsequent testing was done for z-purlin applications in May 1997 using (.037”) or 20 SAMMYS FOR WOOD - PIPE HANGER gauge steel. Most recently in 2008, testing with the new Sammy X-Press® was completed using (.030”) or 22 gauge steel metal deck. WOOD 8007957 GST 10 3/8” Vertical CPVC 1-1/2” 300 1-1/2” 8020957 SWG 10 3/8” Horizontal CPVC 1-1/2” 300 1-1/2” Sammys® Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is 8008957 GST 20 3/8” Vertical 2-1/2” 850 1-1/2” 4” 1475 1-1/2” complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. 8068925 GST 20-SS 3/8” Vertical 2-1/2” 850 1-1/2” 8010957 GST 30 3/8” Vertical 4” 1500 1-1/2” 4” 1475 1-1/2” Steel Screws 8009925 GST 25-380 3/8” Vertical 4” 1500 1-1/2” Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be 8022925 SWG 25-380 3/8” Horizontal 3-1/2” - 4”* 1500 1-1/2” used. 8021957 SWG 20 3/8” Horizontal 2-1/2” - 3”** 1050 1-1/2” 8073925 SWG 20-SS 3/8” Horizontal 2-1/2” 850 1-1/2” Metric Products 8269957 SH-GST/CST 20 3/8” 45° Angle off Vertical 2-1/2” 850 1-1/2” Metric versions of the Sammy anchors are available at www.itwbuildex.com 8269957 SH-GST/CST 20 3/8” 45° Angle off Vertical 4” 1500 1-1/2” Sammys for Seismic 8139957 SH-GST 20 3/8” 17° Angle off Vertical 3” 1050 1-1/2” 4” 1475 1-1/2” Please visit www.itwbuildex.com for our current Seismic product offerring. STEEL SAMMYS FOR STEEL - PIPE HANGER Min Steel Thick Max Steel Thick 8038957 DSTR 1 3/8” Vertical 4” 1500 .035” 4” 1475 .105” Vibratory Environments For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. 8037957 DSTR 1-1/2 3/8” Vertical 4” 1500 .035” 4” 1475 .105” Consult local code authorities for accepted anchoring devices. 8039957 DSTR 516 3/8” Vertical 4” 1500 .037” 4” 1475 .105” 8045957 DST 516 3/8” Vertical 4” 1500 .188” 4” 1475 .188” Composite Joist/Truss 8046957 TEK 50 3/8” Vertical 4” 1500 .250” 4” 1475 .188” Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can 8055957 SWDR 1 3/8” Horizontal 4” 1500 .037” 4” 1475 .060” be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by 8056957 SWDR 516 3/8” Horizontal 4” 1500 .037” 4” 1475 .060” some joist manufacturers. Consult truss manufacturer for recommended installation point. 8054957 SWDR 1-1/2 3/8” Horizontal 4” 1500 .037” 4” 1475 .060” 8137957 SH-DSTR 1 3/8” 17° Angle off Vertical 4” 1500 .035” 4” 1475 .105” Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8” smaller than root diameter of fastener. Vertical 2-1/2” 850 8268957 SH-TEK 50 3/8” 70° Angle off Vertical 4” 1500 Consult the table below: 2” 940 .029” Model Root Diameter Hole Size 8150922 XP 20 3/8” Vertical 2-1/2” 850 .027” STEEL 4” 1475 .105” GST 20 .182” 1/8” 2” 940 .029” 8153922 XP 35 3/8” Vertical 4” 1500 .060” GST 25-380 .280” 7/32” 4” 1475 .125” SWG 20 .182” 1/8” 8294922 SXP 20 3/8” Vertical or up to 45° 2” 750 .027” 2” 635 .029” 8295922 SXP 35 3/8” Vertical or up to 89° 3-1/2” 1250 .060” 2” 635 .029” SWG 25-380 .280” 7/32” 8293957 SWXP 35 3/8” Horizontal 3-1/2” 1250 .060” SAMMYS FOR CONCRETE - PIPE HANGER To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. 8059957 CST 20 3/8” Vertical 4” 1475 3000 NFPA/NEC Standards 8061957 SWC 20 3/8” Horizontal 4” 1475 3000 All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. 8150922 XP 20 3/8” Vertical 2-1/2” 850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8” Vertical 2-1/2” 850 Post-Pour Range II LWC ≤ 35 PCF (lbs/ft3) UL Listings / FM Approvals UL and FM reports are available at www.itwbuildex.com CONCRETE Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Assembled in the U.S.A. Products Contact Information Assembled U.S.A. Technical Assistance: (800) 848-5611 Option #6 (x 3259) Customer Service: (800) 848-5611 Option #1 ACCESSORIES APPROVALS 15 To find a distributor near you, call 800-848-5611 AFCON® Seismic Braces Longitudinal & Lateral Seismic Clamp Fig. AF730 Material Specifications Size Range Service Pipe Size: 1" - 12", DN25-DN100 Material Carbon Steel Clamp and Hardware. Ductile Iron Brace Member Attachment Fitting. Finish Plain Clamp: Hot Dipped Galvanized per ASTM A153 Brace Member Attachment Fitting: Electro-Galvanized per ASTM B633 A Service A seismic longitudinal and lateral brace clamp designed to connect a piping system to a brace member. The AF730 rigidly braces piping systems B subjected to horizontal and vertical seismic loads. Y Approvals cULus Listed (ANSI/UL 203a) and FM Approved (FM 1950-13). FM Tested (ANSI/FM 1950-16). Complies with NFPA 13, ASCE 7, IBC, & MSS FIG. AF730 Dimensions and Weight SP-127 bracing requirements. A B Y Weight Size Features In./mm In./mm In./mm lbs/kgs • Torque off set screw and nuts provide a visual 1" (DN25) 7.6 193 2.49 1.13 indication that the desired installation torque values have been achieved. 1½" (DN32) 8.0 203 2.55 1.13 Ordering 1½" (DN40) 8.2 208 2.64 1.20 Specify figure number, service pipe size, finish, 2" (DN50) 8.7 221 2.78 1.26 and description. 2½" 9.2 234 2.92 1.32 Disclaimer: ASC Engineered Solutions does not provide any warranties 3" (DN80) 9.8 249 3.13 1.42 and specifically disclaims any liability whatsoever with 1.50 38.1 1.91 48.5 respect to ASC bracing products and components that 4" (DN100) 10.8 274 3.38 1.53 are used in combination with products, parts or systems not manufactured or sold by ASC. In no event shall ASC 5" 12.1 307 3.81 1.73 be liable for any incidental, direct, consequential, special or indirect damages or lost profits where non-ASC bracing 6" 13.2 335 4.12 1.87 components have been, or are used. Seis Brace® Seismic Fire Protection Design Tool may be 8" 15.2 386 6.40 2.90 accessed at www.seisbrace.com 10" 18.1 460 7.60 3.45 12" 20.1 511 8.60 3.90 Notes: ASC Engineered Solutions™ brand bracing components are designed to be compatible ONLY with other ASC Engineered Solutions brand bracing components, resulting in a Listed seismic bracing assembly. Updated UL listing information may be viewed at www.ul.com and updated FM approval information may be viewed at www.approvalguide.com. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SS-07.20 page 1 SS-SUB-AF730-v04 20221228 AFCON® Seismic Braces Longitudinal & Lateral Seismic Clamp Fig. AF730 FIG. AF730 cULus Listing per ANSI/UL 203a (ASD) Horizontal Load Rating at Brace Angle Service Standard Specialty Longitudinal Load Rating Lateral Load Rating Pipe Service Service Size Pipe Pipe 30˚-44˚ 45˚-59˚ 60˚-90˚ Listed 30˚-44˚ 45˚-59˚ 60˚-90˚ Listed lbf/kN lbf/kN lbf/kN lbf/kN lbf/kN lbf/kN lbf/kN lbf/kN Mega-Thread Sch. 10 1" MLT / GL 340 480 588 680 340 480 588 680 Sch. 40 (DN25) Eddy Thread 1.51 2.14 2.62 3.02 1.51 2.14 2.62 3.02 Metric Pipe EZ-Thread Mega-Flow MLT / GL Sch. 10 1¼" Mega-Thread Sch. 40 (DN32) Eddy Flow Longitudinal Application Metric Pipe Eddy Thread EZ-Thread Mega-Flow MLT / GL Sch. 10 Mega-Thread 1½" Sch. 40 Eddy Flow 375 530 649 750 375 530 649 750 (DN40) Metric Pipe Eddy Thread 1.67 2.36 2.89 3.34 1.67 2.36 2.89 3.34 Fire-Flo EZ-Thread Mega-Flow MLT / GL Sch. 10 Mega-Thread 2" Sch. 40 Eddy Flow (DN50) Metric Pipe Eddy Thread Fire-Flo EZ-Thread Mega-Flow Sch. 10 Eddy Flow 2½" Sch. 40 Fire-Flo Lateral Application 545 770 943 1090 545 770 943 1090 2.42 3.43 4.19 4.85 2.42 3.43 4.19 4.85 Sch. 10 Mega-Flow 3" Sch. 40 Eddy Flow (DN80) Metric Pipe Fire-Flo Sch. 10 Mega-Flow 4" Sch. 40 Eddy Flow (DN100) Metric Pipe Fire-Flo Sch. 10 5" – Sch. 40 Sch. 10 942 1333 1632 1885 942 1333 1632 1885 6" Mega-Flow Sch. 40 4.19 5.93 7.26 8.38 4.19 5.93 7.26 8.38 Sch. 10 8" 0.188" Wall – Riser Application Sch. 40 0.188" Wall 10" – Sch. 40 Brace Angles are determined from Vertical. Sch. 10 & 0.188" Wall Load Ratings may be used for any thicker wall pipe of the same diameter. Listed load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. See table on page 4 for UL listed specialty pipes & UL Listed metric service pipes. asc-es.com See table on page 4 for UL listed brace members. Load ratings include a minimum safety factor of 2.2 in accordance with NFPA 13-2019 Section A.18.5.2.3. All load ratings may be used for NFPA 13-2016 designs. SS-07.20 page 2 SS-SUB-AF730-v04 20221228 AFCON® Seismic Braces Longitudinal & Lateral Seismic Clamp Fig. AF730 FIG. AF730 FM Approved (Listing) per FM 1950-13 (ASD) Horizontal Load Rating at Brace Angle Service Standard Specialty Longitudinal Load Rating Lateral Load Rating Pipe Service Service Size Pipe Pipe 30˚-44˚ 45˚-59˚ 60˚-74˚ 75˚-90˚ 30˚-44˚ 45˚-59˚ 60˚-74˚ 75˚-90˚ lbf/kN lbf/kN lbf/kN lbf/kN lbf/kN lbf/kN lbf/kN lbf/kN Sch. 10 Mega-Thread 1" Sch. 40 MLT / GL 550 640 670 740 1740 2460 3010 3360 (DN25) Metric Pipe Eddy Thread 2.24 2.84 2.98 3.29 7.74 10.94 13.39 14.95 EZ-Thread Mega-Flow Sch. 10 MLT / GL 1¼" Sch. 40 Mega-Thread 740 680 820 1620 1430 2020 2480 2770 (DN32) Metric Pipe Eddy Flow 3.29 3.02 3.65 7.21 6.36 8.99 11.03 12.32 Eddy Thread Longitudinal Application EZ-Thread Mega-Flow MLT / GL Sch. 10 Mega-Thread 1½" Sch. 40 800 650 790 1800 1790 2530 3100 3460 Eddy Flow (DN40) Metric Pipe 3.56 2.89 3.51 8.01 7.96 11.25 13.79 15.39 Eddy Thread Fire-Flo EZ-Thread Mega-Flow MLT / GL Sch. 10 Mega-Thread 2" Sch. 40 830 990 1190 1620 1820 2580 3160 3530 Eddy Flow (DN50) Metric Pipe 3.69 4.4 5.29 7.21 8.1 11.48 14.06 15.7 Eddy Thread Fire-Flo EZ-Thread Mega-Flow Sch. 10 800 700 850 1930 1610 2280 2790 3120 2½" Eddy Flow Sch. 40 3.65 3.11 3.78 8.59 7.16 10.14 12.41 13.88 Fire-Flo Sch. 10 Lateral Application Mega-Flow 3" Sch. 40 960 1330 1540 1700 1550 2200 2690 3010 Eddy Flow (DN80) Metric Pipe 4.27 5.92 6.85 7.56 6.89 9.79 11.97 13.39 Fire-Flo Sch. 10 Mega-Flow 4" 760 1040 1270 1400 1260 1790 2190 2440 Sch. 40 Eddy Flow (DN100) 3.38 4.63 5.65 6.23 5.6 7.96 9.74 10.85 Metric Pipe Fire-Flo Sch. 10 890 1230 1410 1550 1260 1790 2190 2440 5" – Sch. 40 3.96 5.47 6.27 6.89 5.6 7.96 9.74 10.85 Sch. 10 700 940 1140 1310 950 1340 1640 1830 6" Mega-Flow Sch. 40 3.11 4.18 5.07 5.83 4.23 5.96 7.3 8.14 0.188" Wall 990 1130 1360 1520 1540 2170 2660 2970 8" – Sch. 40 4.4 5.03 6.05 6.76 6.85 9.65 11.82 13.21 Riser Application 0.188" Wall 1020 850 1000 1100 1700 2410 2950 3290 10" – Sch. 40 4.54 3.78 4.45 4.89 7.56 10.72 13.12 14.63 0.188" Wall 970 1010 1220 1430 1690 2390 2930 3270 12" – Sch. 40 4.31 4.49 5.43 6.36 7.52 10.63 13.03 14.55 Brace Angles are determined from Vertical. Sch. 10 & 0.188" Wall Load Ratings may be used for any thicker wall pipe of the same diameter. Load ratings include a minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3. To convert the load ratings above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.5.2.3, multiply load ratings asc-es.com by a factor of 0.68. To convert to LRFD Load Ratings, ASD Load Ratings may be multiplied by a factor of 1.5. See table on page 4 for FM approved metric service pipes. See table on page 4 for FM approved brace members. SS-07.20 page 3 SS-SUB-AF730-v04 20221228 AFCON® Seismic Braces - Installation Longitudinal & Lateral Seismic Clamp Fig. AF730 Method 1 – Connection to Brace Member First 1 Slide the brace member over the lower jaw until it contacts the back wall of the brace member attachment fitting. 2 Hand tighten the set screw until it contacts the brace member. Continue to torque the set screw until the head breaks off. 3 Rotate the brace assembly to the service pipe. Unbolt the back nut & bolt and rotate the clamp halves over the service pipe. Re-assemble the nut and bolt. 4 Hand tighten the nuts on both sides of the clamp. Evenly and alternately torque the nut until the head breaks off. It is best practice to tighten the nut at the jaw side first. 5 Ensure the brace angle is within the range specified. Method 2 – Connection to Service Pipe First 1 Unbolt the back nut & bolt and rotate the clamp halves over the service pipe. Re-assemble the nut and bolt. 2 Hand tighten the nuts on both sides of the clamp. Evenly and alternately torque the nut until the head breaks off. It is best practice to tighten the nut at the jaw side first. 3 Slide the brace member over the lower jaw until it contacts the back wall of the brace member attachment fitting. 4 Hand tighten the set screw until it contacts the brace member. Continue to torque the set screw until the head breaks off. FIG. AF730 cULus Listed & FM Approved Brace Members Brace Member Sizes Standards (or Equivalent) UL Listed FM Approved Sch. 40 ASTM A53, A106, A135, or NPS Pipe 1", 1¼", 1½", 2" A795 3 3 Sch. 40 Metric Pipe KS D 3562 3 3 EN10255H 3 DN25, DN32, DN40, DN50 Metric Pipe GB/T 3091 3 JIS G3454 3 FIG. AF730 cULus Listed & FM Approved Metric Service Pipes Brace Member Service Pipe Sizes UL Listed FM Approved KS D 3507 3 3 KS D 3537 KS D 3562 3 3 Sch. 40 GB/T 3091 3 GB/T 3092 DN25, DN32, DN40, DN50, DN 80, DN100 JIS G3452 3 EN 10255M asc-es.com EN 10255H SS-07.20 page 4 SS-SUB-AF730-v04 20221228 AFCON® Seismic Braces Model Q Lateral Sway Brace Fig. AF001 Material Specifications Size Range: Service Pipe Size: 1" – 4", DN25 – DN100 Brace Member: 1" – 1¼", DN25 – DN32 Material Carbon Steel Finish Plain Electro-Galvanized Service A seismic lateral brace designed to connect a brace member to the service pipe. The AF001 rigidly braces steel piping systems subjected to horizontal and vertical seismic loads. Approvals cULus Listed (ANSI/UL 203a), FM Approved (FM 1950-13), & OSHPD (OPM-0351-13). Complies with NFPA 13, ASCE 7, IBC, & MSS SP-127 bracing 1" to 4" Service Pipe requirements. Features The indicator clip provides a visual indication that proper installation has been achieved.. Ordering OPM-0351-13 Specify figure number, service pipe size, brace size, finish, and description. FIG. AF001: Weight and Installation Torque Brace Member Size Service Pipe Size Installation Torque 1" (DN25) 1" (DN25) 1" (DN25) 0.82 lbs 0.87 lbs 1¼" (DN32) 0.86 lbs 0.90 lbs 14 ft-lbs 1½" (DN40) 0.90 lbs 0.95 lbs 2" (DN50) 0.96 lbs 1.00 lbs 2½" 1.02 lbs 1.06 lbs 16 ft-lbs DN65 1.05 lbs 1.09 lbs 3" (DN80) 1.09 lbs 1.13 lbs 4" (DN100) 1.23 lbs 1.26 lbs 17 ft-lbs PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SS-06.21 page 1 SS-SUB-AF001-v03 20220303 AFCON® Seismic Braces Model Q Lateral Sway Brace Fig. AF001 FIG. AF001 cULus Listing per ANSI/UL 203a (ASD) Horizontal Load Rating at Brace Angle Service Pipe Size Service Pipe 30°-44° 45°-59° 60°-90° Listed ½" 1" (DN25) (M12) 1¼" (DN32) Sch. 10 1½" (DN40) Sch. 40 Metric Pipe 2" (DN50) 340 lbf 480 lbf 588 lbf 680 lbf Lateral Application (1.51 kN) (2.14 kN) (2.62 kN) (3.02 kN) Sch. 10 2½" Sch. 40 DN65 Metric Pipe 3" (DN80) Sch. 10 Sch. 40 4" (DN100) Metric Pipe 1) Brace Angles are determined from Vertical. 2) Sch. 10 Load Ratings may be used for any thicker wall pipe of the same diameter. 2" Min. 3) Listed load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. 4) Load Ratings reflect 1" (DN25) – 1¼" (DN32) brace members. See table below for listed brace members. 5) Minimum safety factor of 2.2 in accordance with NFPA 13-2019 Section A.18.5.2.3. Lateral Application Fig. AF001 cULus Listing per ANSI/UL 203A (ASD) for NFPA 13 - 2016 editions or earlier UL’s current Listings are predicated on installation in accordance with the latest edition of NFPA 13. The 2016 and earlier editions of NFPA 13 referenced a minimum safety factor of 1.5 for the load rating as compared to 2.2 for the current edition. The load ratings noted in this table are consistent with the historical cULus Listings that were evaluated to the requirements of UL 203A, Outline of Investigation for Sway Brace Devices for Fire Sprinkler System Piping, based upon a minimum safety factor of 1.5 in accordance with the earlier editions of NFPA 13. The load ratings based upon the 2016 or earlier editions of NFPA 13 should only be used where approved by the Authority Having Jurisdiction (AHJ). Horizontal Load Rating at Brace Angle Service Pipe Size Service Pipe 30°-44° 45°-59° 60°-90° Listed ½" 1" (DN25) (M12) 1¼" (DN32) Sch. 10 1½" (DN40) Sch. 40 Metric Pipe 2" (DN50) 500 lbf 707 lbf 865 lbf 1000 lbf (2.22 kN) (3.15 kN) (3.85 kN) (4.45 kN) Sch. 10 Riser Application 2½" Sch. 40 DN65 Metric Pipe 3" (DN80) Sch. 10 Sch. 40 4" (DN100) Metric Pipe 1) Brace Angles are determined from Vertical. 2) Sch. 10 Load Ratings may be used for any thicker wall pipe of the same diameter. 3) Listed load ratings reduced for angle ranges in accordance with NFPA 13-2016 Table 9.3.5.2.3. 4) Load Ratings reflect 1" (DN25) – 1¼" (DN32) brace members. See table below for listed brace members. 5) Minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3 asc-es.com SS-03.22 page 2 SS-SUB-AF001-v03 20220303 AFCON® Seismic Braces Model Q Lateral Sway Brace Fig. AF001 FIG. AF001FM Approved (Listing) per FM 1950-13 (ASD) Horizontal Load Rating at Brace Angle Service Pipe Size Service Pipe 30°-44° 45°-59° 60°-74° 75°-90° 1" (DN25) 1¼" (DN32) 1½" (DN40) 250 lbf 360 lbf 440 lbf 500 lbf LW2 (1.11 kN) (1.60 kN) (1.96 kN) (2.22 kN) 2" (DN50) Lateral Application 2½" 3" (DN80) 410 lbf 590 lbf 720 lbf 800 lbf 4" (DN100) LW2 (1.82 kN) (2.62 kN) (3.2 kN) (2.56 kN) 1" (DN25) 1¼" (DN32) Sch. 10 Sch. 40 2" Min. 1½" (DN40) Metric Pipe 2" (DN50) 500 lbf 810 lbf 1000 lbf 1100 lbf Lateral Application (2.22 kN) (3.6 kN) (4.45 kN) (4.89 kN) Sch. 10 2½" Sch. 40 DN65 Metric Pipe Sch. 10 3" (DN80) Sch. 40 Metric Pipe Sch. 10 760 lbf 1070 lbf 1320 lbf 1470 lbf 4" (DN100) Sch. 40 (3.38 kN) (4.76 kN) (5.87 kN) (6.54 kN) Metric Pipe 1) Brace Angles are determined from Vertical. 2) LW Refers to FM Approved Lightwall pipe, commonly referred to as Sch. 7 and Flow Pipe. See FM Approval Guide for approved Lightwall pipe. 3) Sch. 10 Load Ratings may be used for any thicker wall pipe of the same diameter. 4) See table below for FM listed specialty pipes & FM Listed metric service pipes. 5) Load Ratings reflect 1” (DN25) – 1¼” (DN32) brace members. See table below for listed brace members. 6) Minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3. To convert the load ratings above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.5.2.3, multiply load ratings by a factor of 0.68. 7) To convert to LRFD Load Ratings, ASD Load Ratings may be multiplied by a factor of 1.5. Riser Application asc-es.com SS-11.21 page 3 SS-SUB-AF001-v03 20220303 AFCON® Seismic Braces - Installation Model Q Lateral Sway Brace Fig. AF001 1 Place the AF001 over the service pipe to be braced. 2 Insert the brace member through the open loop and the bracket. The end of the brace pipe shall extend at least 2in (50.8mm) past the bracket. 3 Hand tighten the nuts equally until the bracket contacts the brace member. Continue to torque the nuts equally and alternately until indicator clip is flat and the installation torque has been achieved. 4 Ensure the brace angle is within the specified range. Notes: The brace member may be installed above or below the service pipe. FIG. AF001 cULus Listed & FM Approved Brace Members Brace Member Sizes Standards (or Equivalent) UL Listed FM Approved Sch. 40 ASTM A53, A106, 1", 1¼" 3 3 NPS Pipe A135, or A795 Sch. 40 Metric Pipe KS D 3562 3 3 DN25 EN10255H 3 DN32 Metric Pipe GB/T 3091 3 JIS G3454 3 FIG. AF001 cULus Listed & FM Approved Metric Service Pipes Brace Member Service Pipe Sizes UL Listed FM Approved KS D 3507 3 3 KS D 3537 KS D 3562 3 3 Sch. 40 DN25 GB/T 3091 DN32 3 GB/T 3092 DN40 DN50 JIS G3452 DN 80 3 DN100 EN 10255M 3 EN 10255H 3 Notes: ASC Engineered Solutions™ brand bracing components are designed to be compatible ONLY with other ASC Engineered Solutions brand bracing components, resulting in a Listed seismic bracing assembly. Updated UL listing information may be viewed at www.ul.com and updated FM approval information may be viewed at www. approvalguide.com. Disclaimer: ASC Engineered Solutions does not provide any warranties and specifically disclaims any liability whatsoever with respect to ASC bracing products and components that are used in combination with products, parts or systems not manufactured or sold by ASC. In no event shall ASC be liable for any incidental, direct, consequential, special or indirect damages or lost profits where non-ASC bracing components have been, or are used. Seis Brace® Seismic Fire Protection Design Tool may be accessed at www.seisbrace.com asc-es.com SS-05.21 page 4 SS-SUB-AF001-v03 20220303 IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS 10.61 FireLock EZ® Rigid Coupling SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 009H The FireLock EZ Style 009H coupling is a rigid, installation-ready coupling for fire protection pipe joining. The coupling’s unique design eliminates loose parts, insures consistent installation and provides substantial gains in productivity. IMPORTANT FireLock EZ Style 009H couplings are recommended for use ONLY on fire protection systems. PATENTED LISTINGS/APPROVALS * The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Standard Pipe Size cULus/FM VdS LPCB Nominal Size Inches/ Sch. 5 Sch.10 Sch. 40 mm psi/KPa psi/kPa psi/KPa psi/kPa psi/kPa 1¼ 175 365 365 365 365 32 1206 2517 2517 2517 2517 1½ 175 365 365 365 365 40 1206 2517 2517 2517 2517 2 175 365 365 365 365 50 1206 2517 2517 2517 2517 2½ 365 365 365 365 N/A 65 2517 2517 2517 2517 365** 365 365 76.1mm N/A N/A 2517** 2517 2517 3 365 365 365 365 N/A 80 2517 2517 2517 2517 4 365 365 365 365 N/A 100 2517 2517 2517 2517 290** 232 300 165.1mm N/A N/A 1999** 1600 2068 6# 290 365 232 365 N/A 150# 1999 2517 1600 2517 * Listed/Approved for wet and dry pipe systems (> –40°F/–40°C). Please refer to the Victaulic Installation Manual (I-009H_009_009V.pdf) for details concerning when supplemental lubrication is required. ** EN-10219(L) for 76.1mm size; EN-10255(M) for 165.1mm size # Regional availability only Speciality Pipe Pressure Rating Pressure Rating – Pressure Rating – Pipe Size – psi/kPa Pa Pipe Size psi/kPakPa Pipe Size psi/kPa/kPa Sch. Inches cULus FM Sch. Inches cULus FM Sch. Inches cULus FM 300 300 300 300 300 300 BLT 1 1/4 – 2 EZT 1 1/4 – 2 MT 1 1/4 – 2 2068 2068 2068 2068 2068 2068 300 300 300 300 300 DF 1 1/4 – 4 FF 1 1/4 – 4 MLT 1 1/4 – 2 N/A 2068 2068 2068 2068 2068 300 300 300 300 DT 1 1/4 – 2 FLF 1 1/4 – 4 N/A ST 1 1/4 – 2 N/A 2068 2068 2068 2068 175 175 300 300 EF 1 1/4 – 4 FLT 1 1/4 – 2 N/A STF 1 1/4 – 4 N/A 1206 1206 2068 2068 300 300 300 300 EL 1 1/4 – 2 FLTL 1 1/4 – 2 N/A TF 2 1/4 – 4 N/A 2068 2068 2068 2068 300 300 300 300 300 300 ET40 1 1/4 – 2 GL 1 1/4 – 2 WLS 1 1/4 – 2 2068 2068 2068 2068 2068 2068 300 300 300 300 175 EZF 3 – 4 MF 1 1/4 – 4 WST 1 1/4 – 2 N/A 2068 2068 2068 2068 1206 300 300 XL 1 1/4 – 2 2068 2068 JOB/OWNER CONTRACTOR ENGINEER System No. __________________________ Submitted By ________________________ Spec Sect ____________ Para __________ Location ____________________________ Date ________________________________ Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_F 10.61_1 IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS 10.61 FireLock EZ® Rigid Coupling STYLE 009H STYLE 009H DIMENSIONS Max. Max. Allow. Work. End Pipe End @ Bolt/Nut Aprx. Size Press. * Load * Sep. † No. – Size Dimensions – Inches/mm Wgt. Ea. Actual Pre-assembled Y Z Nominal Outside (Stab in Size Dia. condition) Joint Assembled Inches Inches psi Lbs. Inches Lbs. mm mm kPa N mm Inches X Y X Y Z kg X 1 1/4 1.660 365 790 0.10 2 - 3/8 x 2 2.95 4.77 2.70 4.63 1.93 1.4 32 42.4 2517 3514 2.54 - M10 x 2 75 121 69 118 49 0.7 1 1/2 1.900 365 1035 0.10 2 - 3/8 x 2 3.19 4.97 2.94 4.79 1.93 1.5 40 48.3 2517 4604 2.54 - M10 x 2 81 126 75 122 49 0.7 STYLE 009H PRE-ASSEMBLED 2 2.375 365 1616 0.12 2 - 3/8 x 2 3.79 5.53 3.45 5.42 1.93 1.9 (PUSH ON CONDITION) 50 60.3 2517 7193 3.05 - M10 x 2 96 140 88 138 49 0.9 2 1/2 2.875 365 2370 0.12 2 - 3/8 x 2 1/2 4.29 6.09 3.92 5.85 1.93 2.1 Y Z 65 73.0 2517 10542 3.05 - M10 x 2 1/2 109 155 100 149 49 1.0 3.000 365 2580 0.12 2 - 3/8 x 2 1/2 4.40 6.31 4.05 5.90 1.93 2.1 76.1 mm 76.1 2517 11476 3.05 - M10 x 2 1/2 112 160 103 150 49 1.0 X 3 3.500 365 3512 0.12 2 - 3/8 x 2 1/2 4.91 6.70 4.55 6.46 1.93 2.3 80 88.9 2517 15622 3.05 - M10 x 2 1/2 125 170 116 164 49 1.0 4 4.500 365 5805 0.17 2 - 3/8 x 2 1/2 5.95 7.82 5.54 7.47 2.14 2.9 100 114.3 2517 25822 4.32 - M10 x 2 1/2 151 199 141 190 55 1.3 STYLE 009H JOINT ASSEMBLED 165.1 mm 6.500 290 9623 0.17 2 - 5/8 x 3 1/4 7.84 10.93 7.55 10.85 2.11 5.69 165.1 1999 42805 4.32 - M16 x 3 1/4 199 278 192 276 54 2.6 6 6.625 290 9997 0.17 2 - 5/8 x 3 1/4 7.96 11.08 7.67 11.99 2.11 5.92 150 168.3 1999 44469 4.32 - M16 x 3 1/4 202 281 195 305 54 2.69 * Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See page 1 of this document for Listed/Approved ratings on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 ½ times the figures shown in the chart on page 1, specific to pipe schedule and size. † The allowable pipe separation dimension shown is for system layout purposes only. FireLock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: • Orange enamel (North America, Asia Pacific) • Red enamel (Europe) Optional Coatings: • Hot dipped galvanized Gasket: • Grade “E” EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.61_2 REV_F IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS 10.61 FireLock EZ® Rigid Coupling STYLE 009H GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009H couplings, use FireLock No. 006 end caps containing the “EZ” marking on the inside face or No. 60 end caps con- taining the “QV EZ” marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009H couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009H coupling. There is no interchanging of gaskets or housings between coupling styles. USE OF FLUSHSEAL GASKETS FireLock EZ couplings are supplied with FireLock EZ Grade “E” Type A gaskets. These gaskets FOR DRY PIPE SYSTEMS include an integral pipe stop, that once installed provides the same benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard FlushSeal gaskets are not compatible and cannot be used with the FireLock EZ couplings. INSTALLATION Reference should always be made to the I-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.61 5731 REV F UPDATED 10/2011 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.61 IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS 10.03 ® FireLock Fittings VNIIPO See Victaulic publication 10.01 for details FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD-developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic IPS-sized couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: • Orange enamel. • Red Enamel in EMEA-I. • Optional: Hot dipped galvanized. JOB/OWNER CONTRACTOR ENGINEER System No. __________________________ Submitted By ________________________ Spec Sect ____________ Para __________ Location ____________________________ Date ________________________________ Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_I 10.03_1 IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS 10.03 FireLock® Fittings DIMENSIONS C to E C to E C to E T C C to to E E NO. 001 NO. 003 NO. 002 NO. 006 No. 001 No. 003 No. 002 No. 006 Size 90° Elbow 45° Elbow Straight Tee Cap Nominal Actual Approx. Approx. Approx. Approx. Size Outside Diameter C to E Weight Each C to E Weight Each C to E Weight Each Thickness “T” Weight Each Inches Inches Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs. mm mm mm kg mm kg mm kg mm kg 1 1/4 1.660 0.8 0.3 — — — — — — 32 42.4 21 0.1 1 1/2 1.900 — — — — — — 0.82 0.4 40 48.3 — — — — — — 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 2 1/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 2.25 2.4 76.1 mm — — — — 76.1 76 1.5 57 1.1 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108 mm — — 108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 6.250 5.50 12.6 3.50 9.2 5.50 17.9 159 mm — — 158.8 140 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.03_2 REV_I IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS 10.03 FireLock® Fittings FLOW DATA Frictional Resistance Size Equivalent Feet/meters of Straight Pipe † Actual No. 002 Nominal Outside Elbows Straight Tee Size Diameter Inches Inches No. 001 No. 003 mm mm 90° Elbow 45° Elbow Branch Run 1 1/4 1.660 1.5 0.8 3.7 1.5 32 42.4 0.5 0.2 1.1 0.5 1 1/2 1.900 2.2 1.1 5.5 2.2 40 48.3 0.7 0.3 1.7 0.7 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 2 1/2 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 3.000 4.5 2.3 11.0 4.5 76.1 mm 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108 mm 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 6.250 9.4 4.9 25.0 9.6 159 mm 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 † The flow data listed is based upon the pressure drop of Schedule 40 pipe. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_I 10.03_3 IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS 10.03 FireLock® Fittings GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009/009V/009H couplings, use FireLock No. 006 end caps containing the “EZ” marking on the inside face or No. 60 end caps containing the “QV EZ” marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.03 1539 REV I UPDATED 2/2010 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.03 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 ® Mechanical-T Bolted Branch Outlets VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N Victaulic Mechanical-T® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a “holefinder” locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- PATENTED ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap II® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. • Optional: Hot dipped galvanized Gasket: (Specify choice*) • Grade “E” EPDM EPDM (Green color code). Temperature range –30°F to +230°F/–34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade “T” nitrile Nitrile (Orange color code). Temperature range –20°F to +180°F/–29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are s ervices for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a l isting of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. __________________________ Submitted By ________________________ Spec Sect ____________ Para __________ Location ____________________________ Date ________________________________ Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_O 11.02_1 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max. Work Approx. Size No. Pressure@ Dimensions Weight Each Run × Branch Hole V ‡ # V ‡ Female Nominal Size 920 Diameter T** Thd. Grv. W Y Z Thd. Grv. Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. Y Z mm 920N kPa -0.00 mm mm mm mm mm mm kg kg 2 1/2 (a) ¤ 500 1.50 2.00 2.53 1.61 5.35 2.75 3.1 × 920N — — 50 15 3450 38.1 51 64 41 136 70 1.5 V 3/4 (a) ¤ 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 920N — — 20 3450 38.1 50 64 41 136 70 1.5 1 (a) ¤ 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 920N — — W 25 3450 38.1 47 64 41 136 70 1.4 1 1/4 (a) †¤ 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 920N GROOVED OUTLET 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1 1/2 (a) †¤ 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 920N 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 2 1/2 1/2 (a) §¤ 500 1.50 2.21 2.74 1.82 5.64 2.75 3.0 Y Z × 920N — — 65 15 3450 38.1 56 70 46 143 70 1.4 3/4 (a) §¤ 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 920N — — V 20 3450 38.1 55 70 46 143 70 1.4 T 1 (a) §¤ 500 1.50 2.06 2.74 1.82 5.64 2.75 2.9 920N — — 25 3450 38.1 52 70 46 143 70 1.4 W 1 1/4 † (a) ¤ 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 920N 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 1 1/2 † (a) ¤ 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 FEMALE THREADED OUTLET 920N 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 1/2 (a) 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 76.1 × 920N — — 15 2065 38.1 56 70 57 164 81 1.8 • Provides a direct branch connection at 3/4 (a) 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 920N — — any location where a hole can be cut 20 2065 38.1 56 70 57 164 81 1.8 in the pipe 1 (a) 920N 300 1.50 2.07 2.75 — 2.25 6.46 3.18 3.8 — 25 2065 38.1 53 70 57 164 81 1.7 • A pressure responsive gasket provides 1 1/4 (a) ¤ 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 920N the seal 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 1/2 (a) ¤ 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 920N • Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 Mechanical-T cross assemblies 3 1/2 (a) ¤ 500 1.50 2.52 3.05 2.28 6.15 2.75 3.4 × 920N — — 80 15 3450 38.1 64 78 58 156 70 1.6 • Pressure rated up to 500 psi/3450 kPa 3/4 (a) ¤ 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 920N — — on steel pipe; also available for use 20 3450 38.1 63 78 58 156 70 1.6 with HDPE pipe 1 (a) 920N 500 1.50 2.38 3.06 — 2.28 6.15 2.75 3.3 — 25 3450 38.1 61 78 58 156 70 1.6 • Sizes from 2 × ½"/50 × 15 mm 1 1/4 (a) †¤ 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 through 8 × 4"/200 × 100 mm 32 (b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 1 1/2 (a) †¤ 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 920N 40 (b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2 (a) ¤ 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 920N 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 3 1/2 2 500 2.50 3.00 3.75 2.44 6.72 3.88 3.8 × 920N — — 90 50 3450 63.5 76 95 62 171 99 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG. 3 Style 920 and Style 920N housings cannot be ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). mated to one another † Available with grooved or female threaded outlet. Specify choice on order. to achieve cross connections. ‡ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT” clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ¤ LPCB approved for fire protection services Ø Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_2 REV_O CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max. Work Approx. Size No. Pressure@ Dimensions Weight Each Run × Branch Hole V ‡ # V ‡ Female Nominal Size 920 Diameter T** Thd. Grv. W Y Z Thd. Grv. Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. Y Z mm 920N kPa -0.00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 2 4 1/2 (a) ¤ 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 V 100 × 15 920N 3450 38.1 77 90 — 68 178 70 1.8 — 3/4 (a) ¤ 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 920N — — 20 3450 38.1 76 90 68 178 70 1.8 W 1 (a) ¤ 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 920N — — 25 3450 38.1 73 90 68 178 70 1.8 GROOVED OUTLET 1 1/4 (a) †¤ 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 920N 32 (b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 1 1/2 (a) †¤ 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 920N 40 (b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 Y Z 2 (a) †¤ 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 920N 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 V 2 1/2 (a) † 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 920 T 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 500 2.75 2.88 4.00 2.69 7.34 4.63 6.4 76.1 mm 920 — — W 3450 69.9 73 102 68 186 118 2.9 3 (a) † 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 920 80 3450 88.9 84 114 105 68 196 130 3.8 2.9 FEMALE THREADED OUTLET 1 1/4 (a)¤ 500 1.75 3.08 3.78 2.63 7.64 3.05 5.0 108.0 × 920N — — 32 3450 44.5 78 96 67 194 78 2.3 1 1/2 (a)¤ 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 • Provides a direct branch connection at 920N — — 40 3450 50.8 83 102 67 194 83 2.3 any location where a hole can be cut 2 (a) 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 920N — — in the pipe 50 3450 63.5 83 102 67 194 102 1.9 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 76.1 mm 920 • A pressure responsive gasket provides 3450 69.9 73 102 102 67 194 109 3.6 3.5 the seal 3 (a) 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 920 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 • Request Publication 11.03 for 5 1 1/2 (a) † 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 × 920 Mechanical-T cross assemblies 125 40 3450 50.8 102 121 121 80 246 94 3.4 3.4 2 (a) † 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 920 • Pressure rated up to 500 psi/3450 kPa 50 3450 63.5 102 121 121 80 246 111 3.7 3.6 on steel pipe; also available for use 2 1/2 (a) † 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 920 with HDPE pipe 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 500 2.75 3.75 4.75 3.16 9.70 4.63 8.0 76.1 mm ¤ 920 — — • Sizes from 2 × ½"/50 × 15 mm 3450 69.9 95 121 80 246 118 3.6 through 8 × 4"/200 × 100 mm 3 (a) † 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 500 2.50 3.75 4.50 3.17 8.00 3.88 8.0 133.0 × 920N — — 50 3450 63.5 95 114 81 203 99 3.6 3 500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 920 — — 80 3450 88.9 97 127 76 240 135 3.6 TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be † Available with grooved or female threaded outlet. Specify choice on order. mated to one another ‡ Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT” clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ¤ LPCB approved for fire protection services Ø Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_O 11.02_3 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max. Work Approx. Size No. Pressure@ Dimensions Weight Each Run × Branch Hole V ‡ # V ‡ Female Nominal Size 920 Diameter T** Thd. Grv. W Y Z Thd. Grv. Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. Y Z mm 920N kPa -0.00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 3 1 1/2 † 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 V 139.7 × 40 920N 3450 50.8 96 114 — 84 209 83 3.2 — 2 † 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 920N — — 50 3450 63.5 95 114 84 209 99 4.1 W 6 1 1/4 (a) 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 × 920N 150 32 (b) 3450 44.5 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 1 1/2 (a) †¤ 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 920N 40 (b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2 (a) †¤ 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 920N 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 Y Z 2 1/2 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 920 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 V 500 2.75 4.15 5.21 3.69 10.51 4.63 8.4 76.1 mm ¤ 920 — — T 3450 69.9 105 132 94 267 118 3.8 3 (a) † 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 920 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 W 4 (a) †¤ 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 920 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET 1 1/2 (a) 500 2.00 4.41 5.13 3.63 9.40 3.25 7.8 159.0 × 920N — — 40 3450 50.8 112 130 92 239 83 3.5 2 (a) 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 920N — — • Provides a direct branch connection at 50 3450 63.5 111 130 92 239 99 3.6 any location where a hole can be cut 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 76.1 mm 920 in the pipe 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 920 • A pressure responsive gasket provides 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 the seal 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 108.0 mm 920 — — 3450 114.3 113 137 92 239 155 4.5 • Request Publication 11.03 for 4 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 920 — — Mechanical-T cross assemblies 100 3450 114.3 96.80 146 92 239 159 8.2 TABLE CONTINUED ON PG. 5 • Pressure rated up to 500 psi/3450 kPa ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). on steel pipe; also available for use † Available with grooved or female threaded outlet. Specify choice on order. with HDPE pipe ‡ Center of run to end of fitting. • Sizes from 2 × ½"/50 × 15 mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 × 4"/200 × 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT” clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ¤ LPCB approved for fire protection services IMPORTANT NOTES: Ø Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_4 REV_O CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max. Work Approx. Size No. Pressure@ Dimensions Weight Each Run × Branch Hole V ‡ # V ‡ Female Nominal Size 920 Diameter T** Thd. Grv. W Y Z Thd. Grv. Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. Y Z mm 920N kPa -0.00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 4 1 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 V 165.1 × 25 920N 3450 38.1 99 116 — 96 237 70 3.6 — 1 1/4 ¤ 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 920N — — 32 3450 44.5 113 130 96 237 83 3.8 W 1 1/2 (a) †¤ 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 920N 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 GROOVED OUTLET 2 (a) † 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 920N 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 76.1 mm 920 3450 69.9 110 130 132 92 267 118 3.9 3.4 Y Z 3 (a) † Ø 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 920 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 V 4 (a) †¤ 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 920 T 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 2 (a) † 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 × 920 200 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 W 2 1/2 (a) † 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 920 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET 500 2.75 5.25 6.25 4.81 12.42 4.56 11.6 76.1 mm ¤ 920 — — 3450 69.9 133 159 122 316 116 5.3 3 (a) †¤ 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 920 • Provides a direct branch connection at 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4 (a) †¤ 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 920 in the pipe 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). • A pressure responsive gasket provides † Available with grooved or female threaded outlet. Specify choice on order. the seal ‡ Center of run to end of fitting. • Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings.` (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT” clearly on order. • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. with HDPE pipe § Vds approved for fire protection services ¤ LPCB approved for fire protection services • Sizes from 2 × ½"/50 × 15 mm Ø Approved for use in China by Tianjin Approvals Company. through 8 × 4"/200 × 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_O 11.02_5 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-T® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. 2 CV and Kv Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for CV /Kv Values: ∆P = Q2 Where: Where:Where: 1 C 2 Q = Flow (GPM) Q = Flow (mQ = Fl3/hr)ow (m3/hr) v ∆P = Pressure Drop (psi) ∆P = Pressure Drop (Bar) ∆P = Pressure Drop (Bar) Q = C x ∆P C = Flow Coefficient v v Kv = Flow CoefficientK = Flow Coefficient v Exaggerated for clarity Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe (per UL 213, Sec. 16) OUTLET SIZE (C = 120)ŧ FT CV/KV Values NOMINAL ACTUAL DIAMETER O.D. In/mm In/mm GROOVED THREADED GROOVED THREADED 1/2 0.840 11 - 2 - 15 21.3 9.4 3/4 1.050 16 - 4 - 20 26.7 13.7 1 1.315 21 25 33.7 3** 8 - 1.8 1 1/4 1.660 50 48 5 1/2 6 32 42.7 42.9 41.1 1 1/2 1.900 53 53 11 11 40 48.3 45.4 45.4 2 2.375 112 104 9 10 1/2 50 60.3 96 89.1 2 1/2 2.875 119 150 20 12 1/2 65 73.0 102 128.5 3.000 161 76.1 mm 16* - - 76.1 138.1 3 3.500 249 237 14 15 1/2 80 88.9 213.4 203.1 4 4.500 421 401 20 22 100 114.3 360.8 343.6 ŧ Hazen-Williams coefficient of friction is 120. * Pipe with a wall thickness of 0.165in./4.2mm. ** 1" FireLock™ Innovative Groove System (IGS) outlet www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_6 REV_O CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Approval Agency Run Size Outlet Size Pipe Rated Working Pressures – psi/kPa Actual Nominal Outside Vds Size Diameter Inches/mm Inches/mm Inches/mm Schedule UL ULC FM LPCB (Style 920) (Style 920N) 21/2 - 6 2.875 - 6.625 400 400 400 290 232 362 All 10, 40 65 - 150 73.0 - 168.3 2755 2755 2755 1999 1599 2496 21/2 - 4 2.875 - 4.500 300 300 300 290 232 362 All DF 65 - 100 73.0 - 114.3 2065 2065 2065 1999 1599 2496 21/2 - 4 2.875 - 4.500 300 300 300 290 232 362 All SF 65 - 100 73.0 - 114.3 2065 2065 2065 1999 1599 2496 6 6.625 300 300 250 290 232 362 3, 4 10 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 300 300 300 290 232 362 3,4 30, 40 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 400 145 21/2 10, 40 — — — — 200 219.1 2755 1000 8 8.625 300 250 145 3,4 10 — — — 200 219.1 2065 1724 1000 8 8.625 300 300 145 3,4 30, 40 — — — 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4 - 8"/100 - 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4"/100 mm, 5"/125 mm, 6"/150 mm and 8"/200 mm diameter pipe. The Style 931 comes with a 2 ½"/65 mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_O 11.02_7 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the I-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV O UPDATED 11/2018 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_L Threaded Fittings I-01 For Fire Protection pressure rating, listing, and approval THREADED FITTINGS information, visit Shurjoint website, www.shurjoint.com for details or contact your SHURJOINT Representative. Shurjoint offers a complete range of ductile iron Class 300 threaded fittings in sizes from ½” to 2½”. Material: Ductile iron ASTM A536 Gr. 65-45-12 and or Shurjoint ductile iron threaded fittings are 100% air ASTM A395 Gr. 65-45-15. tested underwater to ensure leak-free performance. Dimensions: ANSI B16.3 Class 150 except bushings and The Shurjoint ductile iron fitting series is UL listed plugs (B16.14), unions (B16.39) and companion flanges and FM approved, making them the right choice for (B16.42). Please note wall thickness dimensions are fire protection and other general application services. subordinate to Shurjoint UL and FM pressure rating listings and approvals Threads: ANSI B1.20.1 NPT or ISO-7 (BSPT) Finish: Black or electro-zinc plated General Dimensions These dimensions apply to all standard fittings, both straight and reducing. For center-to-face dimensions(*), see fitting tables. Ductile Iron Class 300 threaded fittings are designed to the same dimensions as that of Class 150 malleable iron fittings. Though due to the superior strength characteristics, ductile Iron fittings carry a much higher pressure rating. Laboratory tests confirm Shurjoint ductile iron fittings have passed hydrostatic test pressures exceeding 6,000 psi / 414 Bar, which is equal to four times the 1,500 psi /103 Bar Pipe H E B as specified by ANSI B16.3 for 1½” – 2” sizes. Size Band O.D. Band Width Thread Length (min) in in in in ½ 1.02 0.25 0.43 ¾ 1.46 0.27 0.50 1 1.77 0.30 0.58 1¼ 2.15 0.34 0.67 1½ 2.43 0.37 0.70 2 2.96 0.42 0.75 2½ 3.59 0.48 0.92 Installers who have not used DI threaded fittings before Burst pressure testing of DI threaded fittings (2") should be instructed that the fittings are stronger than the pipe in most cases. In general DI threaded fittings require about a one-half turn less than cast iron fittings. Refer to the installation instructions for further detail. Pressure-Temperature Rating (ANSI B16.3 & B16.14) Nom. Working Pressure (W.O.G.) Working Pressure Rating @150°F / @65°C Saturated Steam ½” – 1” : 2000 psi / 140 Bar Class 1¼” – 2” : 1500 psi / 105 Bar 300 psi (20 Bar) 300 2½”: 1000 psi / 70 Bar *Proof test pressure: 1.5 times the working pressure, non-shock cold water. I-01-1/6 Rev. G 20120315 Threaded Fittings I-01 o MODEL 811 ELBOW 90 Model 811 Elbow 90o Size A Wt. Box Q'ty in in Lbs Pcs ½ 1.12 0.25 240 ¾ 1.31 0.35 120 1 1.50 0.57 70 1¼ 1.75 0.97 40 1½ 1.94 1.17 30 2 2.25 1.83 20 2½ 2.70 3.34 10 MODEL 812 REDUCING ELBOW 90o Model 812 Reducing Elbow 90o Size A B Wt. Box Q'ty in in in Lbs Pcs ¾ x ½ 1.20 1.22 0.35 160 1 x ½ 1.26 1.36 0.46 110 1 x ¾ 1.18 1.45 0.57 90 1¼ x ½ 1.34 1.53 0.64 75 1¼ x ¾ 1.45 1.62 0.68 60 1¼ x 1 1.58 1.67 0.81 55 1½ x ½ 1.41 1.66 0.84 45 1½ x ¾ 1.52 1.75 0.90 45 1½ x 1 1.65 1.80 0.95 40 1½ x 1¼ 1.82 1.88 1.10 35 2 x ¾ 1.60 1.97 1.19 30 2 x 1 1.73 2.02 1.47 25 2 x 1½ 2.02 2.16 1.61 20 2½ x 2 2.39 2.60 2.93 15 MODEL 813 ELBOW 45o Model 813 Elbow 45o Size A Wt. Box Q'ty in in Lbs Pcs ½ 0.88 0.22 250 ¾ 0.98 0.33 150 1 1.12 0.55 90 1¼ 1.29 0.84 50 1½ 1.43 0.92 35 2 1.68 1.63 18 2½ 1.95 2.42 12 I-01-2/6 Rev. G 20120315 Threaded Fittings I-01 MODEL 814 TEE Model 814 Tee Size A Wt. Box Q'ty in in Lbs Pcs ½ 1.12 0.31 150 ¾ 1.31 0.48 90 1 1.50 0.81 60 1¼ 1.75 1.28 35 1½ 1.94 1.72 24 2 2.25 2.57 12 2½ 2.70 4.44 8 MODEL 815 REDUCING TEE Model 815 Reducing Tee Size A B C Wt. Box in in in in Lbs Pcs ¾ ¾ ½ 1.20 1.20 1.22 0.46 95 ½ 1 1.50 1.36 1.50 0.71 55 ½ 1.26 1.20 1.36 0.59 80 ¾ ¾ 1.37 1.31 1.45 0.66 65 1 1 1.50 1.45 1.50 0.77 55 ½ 1.26 1.26 1.36 0.64 65 1 ¾ 1.37 1.37 1.45 0.75 60 ½ 1.34 1.26 1.53 0.79 50 ¾ 1.45 1.37 1.62 0.88 50 1 1 1.58 1.50 1.67 1.01 45 1¼ 1¼ 1.75 1.67 1.75 1.25 40 ½ 1.34 1.34 1.53 0.84 45 1¼ ¾ 1.45 1.45 1.62 0.99 45 1 1.58 1.58 1.67 1.12 40 ½ 1.44 1.31 1.69 0.92 40 ¾ 1.50 1.37 1.75 1.01 40 1 1 1.65 1.50 1.80 1.19 30 1¼ 1.82 1.67 1.88 1.54 30 1½ 1.94 1.80 1.94 1.54 30 ½ 1.41 1.34 1.66 1.08 40 1½ 1¼ ¾ 1.52 1.45 1.75 1.14 40 1 1.65 1.58 1.80 1.39 30 ½ 1.41 1.41 1.66 1.10 35 ¾ 1.52 1.52 1.75 1.17 35 1½ 1 1.65 1.65 1.80 1.36 30 1¼ 1.82 1.82 1.88 1.56 30 1 2 2.25 2.02 2.25 2.13 15 1¼ 2 2.25 2.10 2.25 2.22 15 ½ 1.49 1.41 1.88 1.52 30 ¾ 1.60 1.52 1.97 1.47 25 1½ 1 1.73 1.65 2.02 1.63 20 1½ 2.02 1.94 2.16 2.09 20 2 2 2.25 2.16 2.25 2.33 15 ½ 1.49 1.49 1.88 1.56 20 ¾ 1.60 1.60 1.97 1.61 20 2 1 1.73 1.73 2.02 1.80 20 1¼ 1.90 1.90 2.10 2.09 20 1½ 2.02 2.02 2.16 2.24 15 2½ 2 ¾ 1.74 1.60 2.32 2.35 15 I-01-3/6 Rev. G 20120315 Threaded Fittings I-01 MODEL 815 BULLHEAD TEE Model 815 Bullhead Tee Size A B C Wt. Box in in in in Lbs Pcs ¾ ¾ 1 1.45 1.45 1.37 0.66 65 1¼ 1.67 1.67 1.58 0.97 45 1 1 1½ 1.80 1.80 1.65 1.15 35 1 1½ 1.88 1.80 1.82 1.43 30 1¼ 1½ 1.88 1.88 1.82 1.52 30 1¼ 2 2.10 2.10 1.90 1.80 24 1¼ 2 2.16 2.10 2.02 1.94 20 1½ 1½ 2 2.16 2.16 2.02 2.00 20 2 2 2½ 2.60 2.60 2.39 3.61 10 MODEL 816 REDUCING COUPLING Model 816 Reducing Coupling Size A Wrench Size Wt. Box in in in Lbs Pcs ¾ x ½ 1.63 1-¼ 0.37 150 1 x ½ 1.69 1-¼ 0.37 140 1 x ¾ 1.37 1-½ 0.48 120 1¼ x ¾ 2.06 1-½ 0.59 80 1¼ x 1 2.06 - 0.66 60 1½ x 1 2.31 - 0.84 50 1½ x 1¼ 2.31 - 0.92 45 2 x 1 2.81 - 1.23 35 2 x 1¼ 2.81 - 1.28 30 2 x 1½ 2.81 - 1.66 30 2½ x 2 3.25 - 2.24 18 MODEL 817 CROSS Model 817 Cross Size A B Wt. Box Q'ty in in in Lbs Pcs 1/2 1.12 1.12 0.48 90 3/4 1.31 1.31 0.77 60 1 1.50 1.50 0.95 45 1¼ 1.75 1.75 1.43 25 1½ 1.94 1.94 1.87 20 2 2.25 2.25 2.86 10 Model 817 Reducing Cross Size A B Wt. Box Q'ty in in in Lbs Pcs 1¼x1¼x1x1 1.67 1.58 1.25 30 1½x1½x1x1 1.80 1.65 1.47 24 2 x 2 x 1 x 1 2.02 1.73 1.94 16 I-01-4/6 Rev. G 20120315 Threaded Fittings I-01 MODEL 818 STRAIGHT COUPLING Model 818 Straight Coupling Size A Wrench Size Wt. Box Q'ty in in in Lbs Pcs ½ 1.38 1⅛” 0.18 360 ¾ 1.61 1⅜” 0.26 200 1 1.77 111/16” 0.42 110 1¼ 2.00 2” 0.57 75 1½ 2.20 2¼” 0.77 60 2 2.60 2¾” 1.17 30 2½ 3.00 3⅜” 2.11 18 MODEL 820 CAP Model 820 Cap Size A Wt. Box Q'ty in in in Lbs ½ 0.89 0.14 500 ¾ 1.00 0.20 300 1 1.18 0.33 180 1¼ 1.32 0.46 110 1½ 1.38 0.57 80 2 1.48 0.88 45 2½ 1.77 1.54 25 MODEL 825 EXTENSION PIECE Model 825 Extension Piece Size A Wt. Box Q'ty in in Lbs Pcs ½ x 1½L 1.50 0.18 300 ½ x 2L 2.00 0.22 250 ¾ x 1½L 1.50 0.22 250 ¾ x 2L 2.00 0.26 200 o MODEL 831 LONG STREET ELBOW 90 Model 831 Long Street Elbow 90o Size A B Wt. Box Q’ty in in in Lbs Pcs 1 x ½M 1.50 3.00 0.66 80 1 x 1M 1.50 3.00 0.81 60 I-01-5/6 Rev. G 20120315 Threaded Fittings I-01 MODEL 832 LONG STREET TEE Model 832 Long Street Tee Size A B C Wt Box Q’ty in in in in Lbs Pcs 1 x ½x1M 1.50 1.40 3.00 0.91 50 1 x 1 x 1M 1.50 1.50 3.00 1.03 45 MODEL 827 HEX BUSHING Model 827 Hex Bushing Size A Wt. Box Q'ty in in Lbs Pcs 1 x ½ 1.06 0.20 280 1 x ¾ 1.06 0.18 280 1¼ x 1 1.18 0.29 150 1½ x 1 1.26 0.53 100 1½ x 1¼ 1.26 0.37 100 2 x 1 1.34 0.75 80 2 x 1¼ 1.34 0.75 80 2 x 1½ 1.34 0.64 80 MODEL 819 PLUG Model 819 Plug Size A Wt. Box Q'ty in in Lbs Pcs ½ 0.93 0.09 500 ¾ 1.13 0.18 300 1 1.25 0.25 200 1¼ 1.36 0.42 110 1½ 1.45 0.59 80 2 1.50 0.95 45 General Notes:  Pressure ratings listed are CWP (cold water pressure) or maximum working pressure within the service temperature range of the gasket used in the coupling. This rating may occasionally differ from maximum working pressures listed and/or approved by UL, ULC, and/or FM as testing conditions and test pipes differ. For additional information contact Shurjoint..  Maximum working pressures and end loads listed are total of internal and external pressures and loads based on Sch. 10 steel pipe with roll grooves to ANSI/AWWA C606-07 specifications. For information on other pipe schedules contact Shurjoint..  For one time field test only the maximum joint working pressure may be increased 1½ times the figures shown.  Warning: Piping systems must always be depressurized and drained before attempting disassembly and or removal of any components.  Shurjoint reserves the right to change specifications, designs and or standard equipment without notice and without incurring any obligations. Job Name: System No. Location: Contractor: Approved: Date: Engineer: Approved: Date: Shurjoint product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Shurjoint Technical Service. Shurjoint reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligations to make such changes and modifications on Shurjoint products previously subsequently sold. I-01-6/6 Rev. G 20120315 Permit #: 6692 Permit Date: 08/28/25 Permit Type: FIRE SPRINKLER Project Name: Senior Aerospace TI Applicant Name: Burns Fire Protection Systems, Inc. Applicant Address: PO Box 1110 Applicant, City, State, Granite Falls Zip: Contact: Audra Williams Phone: 3606912235 Email: audra@burnsfire.com Scope of Work: modification of sprinkler protection to existing space to conform with new clean room addition. Valuation: 8400.00 Square Feet: 9989 Number of Stories: 1 Construction Type: lA Occupancy Group: A-1; Assembly ID Code: Permit Issued: 09/08/2025 Permit Expires: 03/06/2026 Form Permit Type: FIRE SPRINKLER Status: ISSUED Assigned To: Kristin Foster Property Parcel # Address Legal Description Owner Name Owner Phone Zoning JENSEN BUSINESS 637 Warehousing & 00769800000700 20325 71ST AVE NE PARKS LLC Storage Services Contractors Contractor Primary Contact Phone Address Contractor Type License License # Burns Fire Protection CONSTRUCTION Audra Williams 360-691-2235 PO Box 1110 COA 603 467 812 Systems CONTRACTOR Burns Fire Protection CONSTRUCTION Labor & Audra Williams 360-691-2235 PO Box 1110 BURNSFP841DU Systems CONTRACTOR Industries Burns Fire Protection CONSTRUCTION Audra Williams 360-691-2235 PO Box 1110 NICET 86528 Systems CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status FS05. Requesting Hydro, Cover 09/17/2025 ABOVEGROUND 09/18/2025 FIRE Assigned and Final if possible HYDRO FS06. Requesting 09/17/2025 ABOVEGROUND 09/18/2025 FIRE Assigned Hydro/Cover/Final COVER Requesting FS07. FIRE 09/17/2025 Hydro/Cover/Final if 09/18/2025 09/18/2025 FIRE Approved SPRINKLER FINAL possible Plan Reviews Date Review Type Description Assigned To Review Status 08/29/2025 FIRE SPRINKLER BUILDING Approved 08/29/2025 FIRE SPRINKLER AMT Sprinkler Plan Review approved FIRE Approved Fees Fee Description Notes Amount Enter 1 if permit is for: fire alarm, or fire Web Only - Fire System Plan Review $200.00 sprinkler Processing/Technology $25.00 Fire Sprinkler System Commercial NFPA 13/13R $450.00 Credit Card Service $20.25 Total $695.25 Attached Letters Date Letter Description 09/08/2025 Building Permit 08/28/2025 Web Form - Building Application Payments Date Paid By Description Payment Type Accepted By Amount 09/08/2025 Alan D 242371400 Hannah Hardwick $20.25 XBP Conf: 09/08/2025 $675.00 242371400 Outstanding Balance $0.00 Uploaded Files Date File Name 09/08/2025 28163654-2025_BLD6692_Issued Permit.pdf 09/08/2025 28161621-20250828_BLD6692_Approved Plans.pdf 08/29/2025 28057468-20250828_BLD6692_Plans.pdf 08/29/2025 28057469-20250828_BLD6692_Material and Equipment.pdf 08/29/2025 28057470-20250828_BLD6692_Application.pdf