Loading...
HomeMy WebLinkAbout505 E 3rd St_BLD6649_2025 CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 505 E 3RD STREET Permit #: 6649 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 31050200401500 DATE OF ISSUANCE. Scope of Work: new freezer and cooler fire sprinkler modification Valuation: 35000.00 OWNER APPLICANT CONTRACTOR ARLINGTON SCHOOL DISTRICT 16 Southeast Fire Protection Southeast Fire Protection 315 N FRENCH AVENUE 113 Harvest Way #12 113 Harvest Way ARLINGTON, WA 98223 Sitka, AK, 99835 Sitka, AK 99835 2069728125 206-972-8125 LIC: 603 316 812 EXP: 07/31/2026 LIC: SOUTHFP879NR EXP: 08/19/2027 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC #: EXP: LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE SPRINKLER CODE YEAR: 2021 STORIES: 2 CONST. TYPE: VB DWELLING UNITS: OCC GROUP: E; Education BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 09/08/2025 Applicant Signature Date Building Official Date CONDITIONS Adhere to the approved plans. Permit shall be onsite for inspections. Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/08/2025 Fire System Plan Review $480.12 09/08/2025 Credit Card Service $14.40 09/08/2025 Processing/Technology $25.00 09/08/2025 Fire Sprinkler System $225.00 Total Due: $744.52 Total Payment: $744.52 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail ABBREVATIONS SYMBOL LEGEND HEAD LEGEND GENERAL NOTES QTY. ADJ Adjustable 1. The system design and installation shall comply with NFPA 13 2019 and the FIN. AFF Above Finished Floor SYMBOL DESCRIPTION SIN # NPT K FACTOR TEMP FINISH/ESCUTCHEON PROJECT COMMENTS Authority Having Jurisdiction. Upright Sprinkler TOTALS AHJ Authority Having Jurisdiction ANSI American National Standards Institute Pipe Diameter (inches) TYCO TY-FRB UPRIGHT TY313 1/2" 5.6 200° BRASS 12 2. Hazard classification: ORIF. AS Automatic Sprinklers JOB TOTAL New Sprinkler Branchline - Steel Ordinary Hazard I ASME American Society of Mechanical Engineers Pipe Length (feet-inches) .15 gpm per sq. ft. over most remote *1,950 sq. ft. T° F ASR Automatic Sprinkler Riser (U.O.N.) *area of operation increased 30% for dry system ASTM American Society for Testing and Materials Existing Sprinkler Pipe - Steel Actual remote area entire freezer/cooler - 1,112 sq. ft. ATR All Thread Rod SIZE Min. sprinkler system flow (.15 X 1950) = 292.5 gpm AUX Auxiliary Per NFPA 13: 2019 paragraph 27.2.4.2.4 additional flow is added at hydraulic AV Alarm Valve Change in Pipe Elevation reference node 17 (81.5 gpm). AWS American Welding Society TOTALS 12 COMMENTS BB Below Beam 3. Provide spare sprinklers & wrenches within head cabinet as required. BD Below Deck BFP Backflow Preventor System Riser (Wet) BFV Butterfly Valve Existing 4. All piping to be as follows: BJ Below Joist All threaded piping to be schedule 40 black steel or equal. BL Branchline System Riser (Dry) All grooved pipe to be schedule 10 black steel or equal. BLDG Building Existing BOR Base Of Riser UPRIGHT SPRINKLER DETAIL 5. Fittings shall be class 125 threaded cast iron ANSI B16.4. BR Brass Hydraulic Reference Point CH Chrome 6. All threaded pipe and fittings shall have threads cut to ANSI/ASME standard CI Cast Iron SCALE: NTS B1.20.1. CL Centerline Grooved Coupling COJ Cut On Job 7. All pipe welding shall be in compliance with the requirements of AWS B2.1 DESCRIPTION COL Column (standard for building service piping). CONC Concrete Auxiliary Drain (NOTE: ALL SPRINKLERS SUBJECT TO MECHANICAL DAMAGE TO HAVE HEAD GUARDS) COUP Coupling 8. All piping shall be earthquake braced as outlined in NFPA 13 2019. CPVC Chlorinated Polyvinyl Chloride CSP Combination Standpipe Grooved Cap 9. Electrical wiring and any painting of the pipe that may be required shall be by CSR Coach Screw Rod others. CTR Center CV Check Valve Threaded Cap 10. All piping is to be hydrostatically tested at 200 psi minimum, for a period not less DCV Detector Check Valve than two hours. DI Ductile Iron DN Down Plug 11. Water Flow Information: Static 64.6 psi Residual 51 psi with 2724 gpm flowing. DSP Dry Standpipe E Existing 12. Provide clearance around all pipe passing through walls, floors, platforms, and EC Extended Coverage Hanger Location foundations in accordance with NFPA 13:2019 paragraph 9.3.4. ELEV Elevation ELL Elbow Fitting 13. Scope of Work: Existing freezer/cooler to be replaced with new freezer/cooler. EQB Earthquake Brace EXP Exposed Hanger Location Demo existing sprinkler system and replace with new system. F Flanged HANGER DETAIL FDC Fire Department Connection P.O. BOX 624 FH Fire Hydrant Sway Bracing ALASKA:(907) 747-3135 LIC. # SOUTHFP879NR FHC Fire Hose Cabinet FHV Fire Hose Valve SITKA, ALASKA 99835 WASHINGTON : (206) 972-8125 MAXIMUM DISTANCE BETWEEN HANGERS HANGER ROD SIZES FLR Floor Lateral Sway Bracing FM Factory Mutual Research (short rod substitution) NOMINAL PIPE NOMINAL PIPE (907) 747-3135 LIC. # A-19275 FOW Face Of Wall 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4" SIZE (in.) SIZE (in.) SOUTHEAST FIRE PROTECTION FP Fire Protection Not In Scope FS Flow Switch STEEL PIPE EXCEPT N/A 12-0 12-0 15-0 15-0 15-0 15-0 15-0 STEEL PIPE EXCEPT N/A 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" FT Foot THREADED LIGHTWALL THREADED LIGHTWALL FTO Field To Order THREADED LIGHTWALL THREADED LIGHTWALL N/A 12-0 12-0 12-0 12-0 12-0 12-0 12-0 N/A 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" G Grooved STEEL PIPE STEEL PIPE GA Gauge GALV Galvanized GB Glass Bulb GOE Groove One End GOL Groove-O-Let GPM Gallons Per Minute GRC Grooved Reducing Coupling GV Gate Valve HDI Hilti Drop-in Anchor HSW Horizontal Sidewall HT Height HV Hose Valve ID Inside Diameter MECH Mechanical MJ Mechanical Joint MRA Most Remote Area MT Mechanical Tee NFPA National Fire Protection Association NIC Not In Contract NO Number NPT National Pipe Thread NTS Not To Scale OC On Center OD Outside Diameter OH Ordinary Hazard OS&Y Outside Screw & Yoke P Plain End PIV Post Indicator Valve PL Property Line POC Point Of Connection PRV Pressure Regulating Valve PS Pressure Switch SWAY BRACE DETAILS PSI Pounds Per Square Inch PVC Polyvinyl Chloride QR Quick Response RES Residential RN Riser Nipple SBB Side Beam Bracket ARLINGTON, WA SCH Schedule 505 E 3RD STREET SHT Sheet SP Standpipe SPK Sprinkler SQ Square SR Standard Response SSP Standard Spray Pendent SSU Standard Spray Upright SW Switch T Thread TEE Tee Fitting LW Threaded Lightwall STRUCTURAL ATTACHMENT - STEEL BEAM - DETAIL "A" PIPE ATTACHMENT - LATERAL TOE Thread One End TOR Top Of Riser TW Thinwall PRESIDENTS ELEMENTARY SCHOOL TYP Typical REVISIONS STRUCTURAL ATTACHMENT - STEEL BEAM - DETAIL "B" PIPE ATTACHMENT - LONGITUDINAL VICINTY MAP SHEET TITLE SCALE: NTS TITLE SHEET WASHINGTON STATE CERTIFICATE OF COMPETENCY DATE: JULY 25, 2025 FIRE PROTECTION SPRINKLER SYSTEMS FILE: 35638 Eric A Price 7/25/25 3437-0508-C Level 3 Date Southeast Fire Protection SOUTHFP879NR Expires Eric Price 12/31/25 FP1 Signature 1 OF 2 QTY. FIN. ORIF. JOB TOTAL T° F (U.O.N.) SIZE WATER FLOW INFORMATION DESCRIPTION (NOTE: ALL SPRINKLERS SUBJECT TO MECHANICAL DAMAGE TO HAVE HEAD GUARDS) P.O. BOX 624 SECTION "A" ALASKA:(907) 747-3135 LIC. # SOUTHFP879NR SITKA, ALASKA 99835 WASHINGTON : (206) 972-8125 (907) 747-3135 LIC. # A-19275 SOUTHEAST FIRE PROTECTION COOLER FREEZER SCALE: 1/4" = 1'-0" T ARLINGTON, WA 505 E 3RD STREET PROJECT LOCATION PRESIDENTS ELEMENTARY SCHOOL REVISIONS KEY PLAN SCALE: NTS OVERHEAD PIPING PLAN SHEET TITLE ALL PIPE TO BE PITCHED FOR DRAINAGE PER NFPA 13 SCALE: 1/4" = 1'-0" OVERHEAD PIPING PLAN WASHINGTON STATE CERTIFICATE OF COMPETENCY DATE: JULY 25, 2025 FIRE PROTECTION SPRINKLER SYSTEMS FILE: 35638 Eric A Price 7/25/25 3437-0508-C Level 3 Date Southeast Fire Protection SOUTHFP879NR Expires Eric Price 12/31/25 FP2 Signature 2 OF 2 FIRE SPRINKLER MATERIAL SUBMITTAL PROJECT: PRESIDENTS ELEMENTARY SCHOOL 505 3RD STREET AELINGTON, WA PREPARED BY: SOUTHEAST FIRE PROTECTION PO BOX 624 SITKA, ALASKA 99835 WASHINGTON: (206) 972-8125 ALASKA: 907-747-3135 LICENSE # SOUTHFP879NR MATERIALS ARE SUBJECT TO CHANGE DUE TO AVAILABILITY MATERIALS SUBSITUTED WILL BE OF EQUAL QUALITY TO THOSE SUBMITTED Worldwide www.tyco-fire.com Contacts Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage with a finished ceiling. This recessed IMPORTANT pendent sprinkler uses one of the Refer to Technical Data Sheet following: TFP2300 for warnings pertaining to regulatory and health information. • A two-piece Style 15 Recessed Escutcheon with recessed adjust- Always refer to Technical Data ment up to 5/8 in. (15,9 mm) from Sheet TFP700 for the “INSTALLER the flush pendent position. WARNING” that provides cautions with respect to handling and instal- • A two-piece Style 20 Recessed lation of sprinkler systems and com- Escutcheon with recessed adjust- ponents. Improper handling and ment up to 1/2 in. (12,7 mm) from installation can permanently damage the flush pendent position. a sprinkler system or its compo- The adjustment provided by the nents and cause the sprinkler to fail Recessed Escutcheon reduces the to operate in a fire situation or cause accuracy to which the fixed pipe drops it to operate prematurely. to the sprinklers must be cut. Intermediate level versions of Series Scan the QR code or enter the URL TY-FRB Sprinklers are described in in a web browser to access the most Technical Data Sheet TFP357. Sprin- up-to-date electronic version of this kler guards and shields are described document. Data rates may apply. in Technical Data Sheet TFP780. NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition Maximum Working Pressure to the standards of any other authori- 175 psi (12.1 bar) ties having jurisdiction. Failure to do so 250 psi (17.2 bar)* may impair the performance of these * The maximum working pressure of 250 psi (17.2 bar) devices. only applies to the listing by Underwriters Laborato- ries, Inc. (UL). The owner is responsible for main- Discharge Coefficient taining their fire protection system docs.jci.com/tycofire/tfp172 K=5.6 GPM/psi½ (80,6 LPM/bar½) and devices in proper operating con- dition. Contact the installing contrac- Temperature Rating General tor or product manufacturer with any See Table A questions. Finishes Description Sprinkler Sprinkler: See Table B Recessed Escutcheon: White Coated, The TYCO Series TY-FRB, 5.6 K-factor, Black Coated, Chrome Plated, or Brass Upright (TY313) and Pendent (TY323) Identification Plated Sprinklers described in this data sheet are quick response, standard coverage, Number (SIN) Physical Characteristics decorative 3 mm glass bulb-type spray Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze sprinklers designed for use in light or TY313 Upright 5 6K, 1/2 in NPT Button . . . . . . . . . . . . . . . . . . . . . .Brass/Copper ordinary hazard, commercial occupan- TY323 Pendent 5 6K, 1/2 in NPT Sealing Assembly ...Stainless Steel w/TEFLON cies such as banks, hotels, and shop- Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Glass Compression Screw . . . . . . . . . . . . . . . . .Bronze ping malls. Technical Deflector . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze The recessed version of the Series Data TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas Approvals See Table A Page 1 of 4 SEPTEMBER 2022 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16" (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* 5 7/16" (11,1 mm) NOMINAL 2" 4 MAKE-IN (50,8 mm) 2 2" 1-3/8" (50,8 mm) (34,9 mm) 3 WRENCH FLATS 1 1/2" NPT** DEFLECTOR* 2-7/8" (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE 2-7/8" DIA. (73,0 mm) WRENCH RECESS 2-1/4" DIA. (USE ONLY FACE OF (57,2 mm) END "A") SPRINKLER FITTING 5/8" (15,9 mm) FIGURE 2 FLUSH W-TYPE 6 3/8±5/16" SPRINKLER WRENCH (9,5±7,9 mm) WRENCH MOUNTING 1/8" RECESS SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON PUSH WRENCH 2-7/8" DIA. IN TO ENSURE (73,0 mm) ENGAGEMENT FACE OF WITH SPRINKLER SPRINKLER 2-1/4" DIA. WRENCHING AREA (57,2 mm) FITTING FIGURE 3 W-TYPE 7 RECESSED 5/16±1/4" 1/2" (12,7 mm) SPRINKLER WRENCH (7,9±6,4 mm) FLUSH MOUNTING 1/8" SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFP172 Page 3 of 4 Sprinkler Finish8 K-Factor Type Temperature Bulb Liquid Natural Chrome Polyesterc Color Brass Plated 135°F (57°C) Orange UPRIGHT 155°F (68°C) Red (TY313) and 175°F (79°C) Yellow 1, 2, 3, 4, 5, 6, 7 PENDENT (TY323) 200°F (93°C) Green 5.6 286°F (141°C) Blue 1/2 in. NPT 135°F (57°C) Orange RECESSED PENDENT 155°F (68°C) Red 1, 2, 3, 4, 7 (TY323) 175°F (79°C) Yellow Figures 4a and 5b 200°F (93°C) Green Notes: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.) 6. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 7. EAC Approved. 8. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. a. Installed with Style 15 (1/2 in. NPT) 5/8 in. Total Adjustment Recessed Escutcheon, as applicable. b. Installed with Style 20 (1/2 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. c. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS Operation Installation Step 2. With pipe-thread sealant applied to the pipe threads, hand- The glass bulb contains a fluid which The TYCO Series TY-FRB, 5.6 K-factor, tighten the sprinkler into the sprinkler expands when exposed to heat. When Upright (TY313) and Pendent (TY323) fitting. the rated temperature is reached, the Sprinklers must be installed in accor- Step 3. Tighten the sprinkler into the fluid expands sufficiently to shatter the dance with this section. sprinkler fitting using only the W-Type glass bulb, allowing the sprinkler to 6 Sprinkler Wrench as shown in Figure General Instructions activate and water to flow. 2. Apply the W-Type 6 Sprinkler Wrench Do not install any bulb-type sprin- to the wrench flats as shown in Figure kler if the bulb is cracked or there is Design a loss of liquid from the bulb. With the 1. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N·m). Criteria sprinkler held horizontally, a small air bubble should be present. The diam- Recessed Pendent Sprinklers eter of the air bubble is approximately The Series TY-FRB Recessed Pendent The TYCO Series TY-FRB, 5.6 K-factor, 1/16 in. (1,6 mm) for the 135°F (57°C) and Sprinklers must be installed in accor- Upright (TY313) and Pendent (TY323) 3/32 in. (2,4 mm) for the 286°F (141°C) dance with the following instructions. Sprinklers are intended for fire protec- temperature ratings. tion systems designed in accordance Step A. After installing the Style 15 with the standard installation rules A leak-tight 1/2 in. NPT sprinkler joint or Style 20 Mounting Plate over the recognized by the applicable Listing or should be obtained by applying a sprinkler threads, and with pipe-thread Approval agency (such as, UL Listing minimum to maximum torque of 7 to sealant applied to the pipe threads, is based on the requirements of NFPA 14 lb-ft (9,5 to 19,0 N·m). Higher levels hand-tighten the sprinkler into the 13, and FM Approval is based on the of torque can distort the sprinkler Inlet sprinkler fitting. requirements of FM’s Loss Prevention with consequent leakage or impairment Step B. Tighten the sprinkler into the Data Sheets). Only the Style 15 or Style of the sprinkler. sprinkler fitting using only the W-Type 20 Recessed Escutcheon is to be used Do not attempt to compensate for 7 Recessed Sprinkler Wrench as for recessed pendent installations. insufficient adjustment in the Escutch- shown in Figure 3. Apply the W-Type eon Plate by under- or over-tightening 7 Recessed Sprinkler Wrench to the the sprinkler. Re-adjust the position of sprinkler wrench flats as shown in the sprinkler fitting to suit. Figure 1. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N·m). Upright and Pendent Sprinklers The Series TY-FRB Upright and Step C. After ceiling installation and Pendent Sprinklers must be installed finishing, slide on the Style 15 or Style in accordance with the following 20 Closure over the Series TY-FRB instructions. Sprinkler and push the Closure over the Mounting Plate until its flange comes in Step 1. Install Pendent sprinklers in the contact with the ceiling. pendent position. Install upright sprin- klers in the upright position. TFP172 Page 4 of 4 P/Na 77 – XXX – X – XXX SPRINKLER TEMPERATURE SIN FINISH RATINGS 370 5.6K UPRIGHT (1/2 in.NPT) TY313 1 NATURAL BRASS 135 135°F (57°C) PURE WHITE (RAL9010)a 371 5.6K PENDENT (1/2 in.NPT) TY323 3 155 155°F (68°C) POLYESTER Notes: SIGNAL WHITE (RAL9003) a. Use suffix “I” for ISO 7-1 connection; for example, 4 175 175°F (79°C) POLYESTER 77-370-4-175-I JET BLACK (RAL9005) 5 200 200°F (93°C) POLYESTER 9 CHROME PLATED 286 286°F (141°C) Notes: a. Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Care and Care must be exercised to avoid Limited damage to the sprinklers before, Maintenance during, and after installation. Sprin- Warranty klers damaged by dropping, striking, The TYCO Series TY-FRB, 5.6 K-factor, wrench twist/slippage, or the like, must For warranty terms and conditions, visit Upright (TY313) and Pendent (TY323) be replaced. Also, replace any sprin- www.tyco-fire.com. Sprinklers must be maintained and ser- kler that has a cracked bulb or that has viced in accordance with this section. lost liquid from its bulb. (Ref. Installa- Ordering tion Section.) Before closing a fire protection system main control valve for maintenance The owner is responsible for the Procedure work on the fire protection system inspection, testing, and maintenance of that it controls, obtain permission to their fire protection system and devices Contact your local distributor for avail- shut down the affected fire protection in compliance with this document, as ability. When placing an order, indicate systems from the proper authorities well as with the applicable standards the full product name and Part Number and notify all personnel who may be of the National Fire Protection Associ- (P/N). affected by this action. ation such as NFPA 25, in addition to Sprinkler Assemblies with NPT the standards of any other authorities Absence of the outer piece of an having jurisdiction. Contact the install- Thread Connections escutcheon, which is used to cover ing contractor or product manufacturer Specify: Series TY-FRB Upright or a clearance hole, can delay sprinkler with any questions. Pendent (specify) Sprinkler, SIN operation in a fire situation. (specify), K=5.6, Quick Response, Automatic sprinkler systems are rec- (specify) temperature rating, (specify) The owner must assure that the sprin- ommended to be inspected, tested, finish, P/N (specify, refer to Table A). klers are not used for hanging any and maintained by a qualified Inspec- objects and that the sprinklers are only tion Service in accordance with local Recessed Escutcheon cleaned by means of gently dusting requirements and/or national codes. Specify: Style 15 Recessed Escutch- with a feather duster; otherwise, non- eon with (specify*) finish, P/N (specify*) operation in the event of a fire or inad- Specify: Style 20 Recessed Escutch- vertent operation may result. eon with (specify*) finish, P/N (specify*) Sprinklers which are found to be * Refer to Technical Data Sheet TFP770 leaking or exhibiting visible signs of Sprinkler Wrench corrosion must be replaced. Specify: W-Type 6 Sprinkler Wrench, Automatic sprinklers must never be P/N 56-000-6-387 painted, plated, coated, or other- Specify: W-Type 7 Sprinkler Wrench, wise altered after leaving the factory. P/N 56-850-4-001 Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. 1467 Elmwood Avenue, Cranston, RI 02910 | Telephone +1-401-781-8220 © 2022 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; TEFLON is a trademark of The Chemours Company FC, LLC SCHEDULE 10, 30, & 40 SPRINKLER PIPE SUBMITTAL DATA SHEET APPROVALS AND SPECIFICATIONS FINISHES AND COATINGS • ASTM A135, Grade A • Schedule 10, 30 & 40 Sprinkler Pipe receives an OD mill coating of water- • ASTM A795, Type E, Grade A based paint which has corrosion protection expected with a painted carbon • Pressure rated to 300 psi steel product, i.e. it would be expected to resist corrosion for an • Underwriters Laboratories— extended and indefinite period in a clean and dry environment and, United States of America as environmental conditions deteriorate, the corrosion protection • Underwriters Laboratories—Canada would also diminish. • Factory Mutual • Schedule 10, 30 & 40 Sprinkler Pipe (black) receives an ID mill coating of • NFPA-13 Eddy Guard II MIC preventative coating. EG2 has been tested at • NFPA-13R independent laboratories to resist bacterial growth and maintain minimal bacterial count after multiple flushes (25) of the pipe. • NFPA-14 • CIVIL DEFENSE APPROVAL— • Schedule 10, 30 & 40 Sprinkler Pipe when Hot Dip Galvanized by ASTM A123 United Arab Emirates and supplied by Bull Moose Tube is UL listed and FM approved. • Made in the United States of America PRODUCT IDENTIFICATION • UL, ULC & FM listed for roll-groove, plain-end and welded joints for wet, dry, • Every length of Bull Moose fire sprinkler pipe features large, easy-to- preaction and deluge sprinkler systems. read, continuous stenciling, clearly identifying the manufacturer, type • LEED v4 Certified of pipe, size, and length. Nominal Pipe Size (inches) 1 1-1/4" 1-1/2" 2" 2-1/2" 3" 4" 6" 8"† 10" O.D. (in) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 10.750 I.D. (in) 1.097 1.422 1.682 2.157 2.635 3.260 4.260 6.357 8.249 10.374 Empty Weight (lb/ft) 1.41 1.81 2.09 2.64 3.53 4.34 5.62 9.29 16.94 21.23 Water Filled Weight (lb/ft) 1.800 2.518 3.053 4.223 5.893 7.957 11.796 23.038 40.086 57.874 Schedule 10 C.R.R.* 15.270 9.910 7.760 6.270 4.920 3.540 2.500 1.158 1.805 2.410 Pieces per Lift 91 61 61 37 30 19 19 10 7 2 O.D. (in)  1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 † I.D. (in) 1.049 1.380 1.610 2.067 2.469 3.068 4.026 6.065 8.071 Empty Weight (lb/ft) 1.68 2.27 2.72 3.66 5.8 7.58 10.8 18.99 24.72 Water Filled Weight (lb/ft)  2.055 2.918 3.602 5.114 7.875 10.783 16.316 31.498 50.240 Schedule 40 & 30 C.R.R.*  1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Pieces per Lift 70 51 44 30 30 19 19 7 7 *Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY SUBMITTAL INFORMATION Project Contractor Engineer Specification Reference Date System Type Locations Comments Schedule 10 - Black Schedule 10 - Hot Dip Galvanized Schedule 30 - Black Schedule 30 - Hot Dip Galvanized Schedule 40 - Black Schedule 40 - Hot Dip Galvanized 1819 Clarkson Road, Chesterfield, MO 63017 800.325.4467 | sales@BullMooseIndustries.com Worldwide www.tyco-fire.com Contacts G-FIRE Grooved Fittings Ductile Iron and Fabricated Steel Ductile NOTICE IMPORTANT Refer to Technical Data Sheet Never remove any piping component TFP2300 for warnings pertaining to nor correct or modify any piping defi- regulatory and health information. ciencies without first de-pressurizing and draining the system. Failure to do so may result in serious personal injury, Scan the QR code or enter the URL property damage, and/or impaired in a web browser to access the most device performance. up-to-date electronic version of this It is the designer’s responsibility document. Data rates may apply. to select products suitable for the intended service and to ensure that pressure ratings and performance data are not exceeded. Material and gasket selection should be verified to be compatible for the specific applica- tion. Always read and understand the installation instructions. The GRINNELL G-FIRE Grooved Fittings described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the approval agency, in addition to the standards of any other authorities having jurisdiction. docs.jci.com/tycofire/tfp1815 Failure to do so may result in serious personal injury or impair the perfor- General mance of these devices. Internal fitting coatings serving as pro- Description tection during storage and transport can become separated after installation GRINNELL G-FIRE Grooved Fittings and during system operation, poten- Technical provide an economical and efficient tially causing blockage of strainers or method of changing direction, adding other filtering equipment. If strainers Data an outlet, reducing, or capping piping are installed in the piping system the systems. The G-FIRE grooved fittings manufacturer recommends they feature Approvals are available in ductile iron or fabri- a minimum 5/32 in. (4 mm) mesh size UL and ULC Listed cated steel as indicated. and, to prevent blockages, that they FM Approved are regularly serviced at intervals to be VdS Approved Note: Figure 510S and 519S fittings are determined by the system designer. LPCB Certified special short radius fittings with smaller The owner is responsible for maintain- Note: LPCB Certification applies to Figures center to end dimensions than stan- ing their system and devices in proper 211, 212, 221, 250, 260, 501, 510, 511, 512, dard grooved fittings. Depending on 519, 550, 510S, and 519S. operating condition. Contact the install- the size and coupling used, there may be interferences at the bolt pads that ing contractor or product manufacturer Material with any questions Cast: Ductile iron conforming to ASTM require repositioning of the coupling A536, Grade 65-45-12 orientation. The use of flange adapters is not recommended with Figures 510S Fabricated Steel: Carbon Steel conforming and 519S fittings. Contact Johnson to ASTM A53, ASTM A135, and ASTM Controls for details. A795 Protective Coatings • Non-lead orange paint (USA) • RAL red or non-lead paint (EMEA and APAC) • Hot dipped galvanized conforming to ASTM A153 Page 1 of 26 AUGUST 2022 TFP1815 TFP1815 Page 2 of 26 Figure 250 Figure 350 Figure 550(a) Nominal Pipe Size Cast Fabricated Cast Nominal Approx. Nominal Approx. Nominal Approx. O.D. ANSI Inches E to E Weight E to E Weight E to E Weight Inches (DN) Inches Lbs. Inches Lbs. Inches Lbs. (mm) (mm) (kg) (mm) (kg) (mm) (kg) 1-1/4 x 1 1.66 x 1.31 2.50 0.7 2.50 0.7 — — (32 x 25) (42,4 x 33,4) (63,5) (0,3) (63,5) (0,3) 1-1/2 x 1 1.90 x 1.31 2.50 0.7 — — — — (40 x 25) (48,3 x 33,4) (63,5) (0,3) 1-1/2 x 1-1/4 1.90 x 1.66 2.50 0.8 2.50 0.8 — — (40 x 32) (48,3 x 42,4) (63,5) (0,3) (63,5) (0,3) 2 x 1 2.37 x 1.31 2.50 0.9 — — — — (50 x 25) (60,3 x 33,4) (63,5) (0,4) E to E 2 x 1-1/4 2.37 x 1.66 2.50 0.9 — — — — (50 x 32) (60,3 x 42,4) (63,5) (0,4) 2 x 1-1/2 2.37 x 1.90 2.50 1.0 — — — — (50 x 40) (60,3 x 48,3) (63,5) (0,5) 2-1/2 x 1 2.87 x 1.31 2.50 1.2 — — — — (65 x 25) (73,0 x 33,4) (63,5) (0,5) FIGURE 250 CAST CONCENTRIC 2-1/2 x 1-1/4 2.87 x 1.66 2.50 1.4 2.50 1.4 — — REDUCER (65 x 32) (73,0 x 42,4) (63,5) (0,6) (63,5) (0,6) E to E 2-1/2 x 1-1/2 2.87 x 1.90 2.50 1.4 — — 2.50 1.4 (65 x 40) (73,0 x 48,3) (63,5) (0,6) (63,5) (0,6) 2-1/2 x 2 2.87 x 2.37 2.50 1.3 2.50 1.3 — — (65 x 50) (73,0 x 60,3) (63,5) (0,6) (63,5) (0,6) 76,1mm x 1-1/4 3.00 x 1.66 2.50 1.4 2.50 1.4 — — (65 x 32) (76,1 x 42,4) (63,5) (0,6) (63,5) (0,6) FIGURE 350 FABRICATED CONCENTRIC 76,1mm x 1-1/2 3.00 x 1.90 2.50 1.4 — — 2.50 1.4 REDUCER (65 x 40) (76,1 x 48,3) (63,5) (0,6) (63,5) (0,6) 76,1mm x 2 3.00 x 2.37 2.50 1.5 2.50 1.5 E to E (65 x 50) (76,1 x 60,3) (63,5) (0,7) — — (63,5) (0,7) 3 x 1 3.50 x 1.31 2.50 1.3 — — — — (80 x 25) (88,9 x 33,4) (63,5) (0,6) 3 x 1-1/4 3.50 x 1.66 2.50 1.3 — — — — (80 x 32) (88,9 x 42,4) (63,5) (0,6) FIGURE 550a 3 x 1-1/2 3.50 x 1.90 2.50 1.8 2.50 1.8 CAST CONCENTRIC (80 x 40) (88,9 x 48,3) (63,5) (0,8) — — (63,5) (0,8) REDUCER 3 x 2 3.50 x 2.37 2.50 1.7 2.50 1.7 — — (80 x 50) (88,9 x 60,3) (63,5) (0,8) (63,5) (0,8) 3 x 2-1/2 3.50 x 2.87 2.50 1.7 2.50 1.7 — — (80 x 65) (88,9 x 70,3) (63,5) (0,8) (63,5) (0,8) 3 x 76,1mm 3.50 x 3.00 2.50 2.0 2.50 2.0 — — (80 x 65) (88,9 x 76,1) (63,5) (0,9) (63,5) (0,9) 4 x 1 4.50 x 1.31 3.00 2.9 — — — — (100 x 25) (114,3 x 33,4) (76,2) (1,1) 4 x 1-1/4 4.50 x 1.66 3.00 2.2 — — — — (100 x 32) (114,3 x 42,4) (76,2) (1,0) 4 x 1-1/2 4.50 x 1.90 3.00 2.3 — — — — (100 x 40) (114,3 x 48,3) (76,2) (1,0) 4 x 2 4.50 x 2.37 3.00 2.4 3.00 2.4 — — (100 x 50) (114,3 x 60,3) (76,2) (1,1) (76,2) (1,1) 4 x 2-1/2 4.50 x 2.87 3.00 2.7 3.00 2.7 — — (100 x 65) (114,3 x 73,0) (76,2) (1,2) (76,2) (1,2) NOTES a. Figure 550 is available for the Americas market only. FIGURE 1 (1 OF 3) FIGURES 250, 350, AND 550 CONCENTRIC REDUCERS NOMINAL DIMENSIONS TFP1815 Page 3 of 26 Figure 250 Figure 350 Figure 550(a) Nominal Pipe Size Cast Fabricated Cast Nominal Approx. Nominal Approx. Nominal Approx. O.D. ANSI Inches E to E Weight E to E Weight E to E Weight Inches (DN) Inches Lbs. Inches Lbs. Inches Lbs. (mm) (mm) (kg) (mm) (kg) (mm) (kg) 4 x 76,1mm 4.50 x 3.00 3.00 3.2 3.00 3.2 — — (100 x 65) (114,3 x 76,1) (76,2) (1,5) (76,2) (1,5) 4 x 3 4.50 x 3.50 3.00 2.8 3.00 2.8 — — (100 x 80) (114,3 x 88,9) (76,2) (1,3) (76,2) (1,3) 139,7mm x 3 5.50 x 3.50 3.50 4.2 3.50 4.2 — — (125 x 80) (139,7 x 88,9) (88,9) (1,9) (88,9) (1,9) 139,7mm x 4 5.50 x 4.50 3.50 4.4 3.50 4.4 — — (125 x 100) (139,7 x 114,3) (88,9) (2,0) (88,9) (2,0) 5 x 2 5.56 x 2.37 3.50 4.6 — — — — (125 x 50) (141,3 x 60,3) (88,9) (2,1) E to E 5 x 2-1/2 5.56 x 2.87 3.50 4.5 — — — — (125 x 65) (141,3 x 73,0) (88,9) (2,0) 5 x 3 5.56 x 3.50 3.50 4.2 3.50 4.2 — — (125 x 80) (141,3 x 88,9) (88,9) 1,9) (88,9) 1,9) 5 x 4 5.56 x 4.50 3.50 4.4 — — 3.50 4.4 FIGURE 250 (125 x 100) (141,3 x 114,3) (88,9) (2,0) (88,9) (2,0) CAST CONCENTRIC REDUCER 165,1mm x 3 6.50 x 3.50 4.00 5.5 4.00 5.5 — — (150 x 80) (165,1 x 88,9) (101,6) (2,5) (101,6) (2,5) E to E 165,1mm x 4 6.50 x 4.50 4.00 6.0. 4.00 6.0. — — (150 x 100) (165,1 x 114,3) (101,6) (2,7) (101,6) (2,7) 165,1mm x 139,7mm 6.50 x 5.50 4.00 5.6 4.00 5.6 — — (150 x 125) (165,1 x 139,7) (101,6) (2,5) (101,6) (2,5) 6 x 1 6.63 x 1.31 4.00 4.7 4.00 4.7 — — FIGURE 350 (150 x 25) (168.3 x 33.7) (101,6) (2,1) (101,6) (2,1) FABRICATED CONCENTRIC 6 x 1-1/2 6.63 x 1.90 4.00 5.0 4.00 5.0 REDUCER — — (150 x 40) (168.3 x 48.3) (101,6) (2,3) (101,6) (2,3) E to E 6 x 2 6.63 x 2.37 4.00 5.3 4.00 5.3 — — (150 x 50) (168,3 x 60,3) (101,6) (2,4) (101,6) (2,4) 6 x 2-1/2 6.63 x 2.87 4.00 5.7 4.00 5.7 — — (150 x 65) (168,3 x 73,0) (101,6) (2,6) (101,6) (2,6) 6 x 76,1mm 6.63 x 3.00 4.00 6.1 4.00 6.1 (150 x 65) (168,3 x 76,1) (101,6) (2,7) — — (101,6) (2,7) FIGURE 550a CAST CONCENTRIC 6 x 3 6.63 x 3.50 4.00 5.8 4.00 5.8 REDUCER — — (150 x 80) (168,3 x 88,9) (101,6) (2,6) (101,6) (2,6) 6 x 108,0mm 6.63 x 4.25 4.00 6.0 — — — — (150 x 100) (168,3 x 108,0) (101,6) (2,7) 6 x 4 6.63 x 4.50 4.00 6.0 4.00 6.0 — — (150 x 100) (168,3 x 114,3) (101,6) (2,7) (101,6) (2,7) 6 x 139,7mm 6.63 x 5.50 4.00 6.3 4.00 6.3 — — (150 x 100) (168,3 x 139,7) (101,6) (2,3) (101,6) (2,3) 6 x 5 6.63 x 5.56 4.00 6.2 4.00 6.2 — — (150 x 125) (168,3 x 141,3) (101,6) (2,8) (101,6) (2,8) 216,3mm x 2-1/2 8.52 x 2.87 5.00 12.1 — — — — (200 x 65) (216,3 x 73,0) (127,0) (5,5) 8 x 3 8.63 x 3.50 5.00 11.5 5.00 11.5 — — (200 x 80) (219,1 x 88,9) (127,0) (5,2) (127,0) (5,2) 8 x 4 8.63 x 4.50 5.00 10.7 5.00 10.7 — — (200 x 100) (219,1 x 114,3) (127,0) (4,9) (127,0) (4,9) NOTES a. Figure 550 is available for the Americas market only. FIGURE 1 (2 OF 3) FIGURES 250, 350, AND 550 CONCENTRIC REDUCERS NOMINAL DIMENSIONS TFP1815 Page 4 of 26 Figure 250 Figure 350 Figure 550(a) Nominal Pipe Size Cast Fabricated Cast Nominal Approx. Nominal Approx. Nominal Approx. O.D. E to E ANSI Inches Inches E to E Weight E to E Weight E to E Weight (DN) Inches Lbs. Inches Lbs. Inches Lbs. (mm) (mm) (kg) (mm) (kg) (mm) (kg) 8 x 139,7mm 8.63 x 5.50 5.00 10.0 5.00 10.0 — — (200 x 125) (219,1 x 139.7) (127,0) (4,5) (127,0) (4,5) 8 x 5 8.63 x 5.56 5.00 10.8 5.00 10.8 — — FIGURE 250 (200 x 125) (219,1 x 141,3) (127,0) (4,9) (127,0) (4,9) CAST CONCENTRIC REDUCER 8 x 165,1mm 8.63 x 6.50 5.00 11.0 — — 5.00 11.0 (200 x 150) (219,1 x 165.1) (127,0) (5,0) (127,0) (5,0) E to E 8 x 6 8.63 x 6.63 5.00 11.3 5.00 11.3 — — (200 x 150) (219,1 x 168,3) (127,0) (5,1) (127,0) (5,1) 10 x 4 10.75 x 4.50 6.00 20.5 — — — — (250 x 100) (273,0 x 114,3) (152,4) (9,3) 10 x 5 10.75 x 5.56 6.00 20.1 — — — — (250 x 125) (273,0 x 141,3) (152,4) (9,1) FIGURE 350 FABRICATED CONCENTRIC 10 x 165,1mm 10.75 x 6.50 6.00 17.8 6.00 17.8 REDUCER — — (250 x 150) (273,0 x 165,1) (152,4) (8,0) (152,4) (8,0) E to E 10 x 6 10.75 x 6.63 6.00 16.3 6.00 16.3 — — (250 x 150) (273,0 x 168,3) (152,4) (7,4) (152,4) (7,4) 267,4mm x 216,3mm 10.52 x 8.52 6.00 17.40 — — — — (250 x 200) (267,4 x 216,3) (152,4) (7,89) 10 x 8 10.75 x 8.63 6.00 18.3 6.00 18.3 — — (250 x 200) (273,0 x 219,1) (152,4) (8,3) (152,4) (8,3) FIGURE 550a CAST CONCENTRIC 12 x 4 12.75 x 4.50 7.00 22.7 7.00 22.7 — — REDUCER (300 x 100) (323,9 x 114,3) (177,8) (10,3) (177,8) (10,3) 12 x 6 12.75 x 6.63 7.00 23.6 7.00 24.2 — — (300 x 150) (323,9 x 168,3) (177,8) (10,7) (177,8) (11,0) 318,5mm x 216,3mm 12.54 x 8.52 7.00 23.12 — — — — (300 x 200) (318,5 x 216,3) (177,8) (10,48) 12 x 8 12.75 x 8.63 7.00 25.2 7.00 25.8 — — (300 x 200) (323,9 x 219,1) (177,8) (11,4) (177,8) (11,7) 318,5mm x 267,4mm 12.54 x 10.52 7.00 25.42 — — — — (300 x 250) (318,5 x 267,4) (177,8) (11,53) 12 x 10 12.75 x 10.75 7.00 28.2 7.00 28.2 7.00 28.2 (300 x 250) (323,9 x 273,0) (177,8) (12,8) (177,8) (12,8) (177,8) (12,8) NOTES a. Figure 550 is available for the Americas market only. FIGURE 1 (3 OF 3) FIGURES 250, 350, AND 550 CONCENTRIC REDUCERS NOMINAL DIMENSIONS TFP1815 Page 5 of 26 Figure 501 Figure 510 Nominal Pipe Size Cast 45° Elbow Cast 90° Elbow Nominal Approx. Nominal Approx. ANSI O.D. C to E Weight C to E Weight Inches Inches Inches Lbs. Inches Lbs. (DN) (mm) (mm) (kg) (mm) (kg) 1 1.0 1.7 0.6 2.25 0.8 (25) (33,7) (43,2) (0,3) (57,2) (0,4) 1-1/4 1.7 1.8 0.8 2.8 1.1 (32) (42,4) (44,5) (0,4) (69,9) (0,5) 1-1/2 1.9 1.8 1.0 2.8 1.4 (40) (48,3) (44,5) (0,5) (69,9) (0,6) C to E 2 2.4 2.0 1.3 3.3 2.0 (50) (60,3) (50,8) (0,6) (82,6) (0,9) 2-1/2 2.9 2.3 2.1 3.8 2.8 (65) (73,0) (57,2) (1,0) (95,3) (1,3) FIGURE 501 CAST 45° ELBOW 76,1mm 3.0 2.3 2.2 3.8 3.0 (65) (76,1) (57,2) (1,0) (95,3) (1,3) 3 3.5 2.5 3.4 4.3 4.1 (80) (88,9) (63,5) (1,5) (108,0) (1,9) 4 4.5 3.0 5.5 5.0 7.0 (100) (114,3) (76,2) (2,5) (127,0) (3,2) 139,7mm 5.5 3.3 7.2 5.5 10.3 C to E (125) (139,7) (82,6) (3,3) (139,7) (4,7) FIGURE 510 165,1mm 6.5 3.5 9.2 6.5 13.9 CAST 90° ELBOW (150) (165,1) (88,9) (4,2) (165,1) (6,3) 6 6.6 3.5 11.2 6.5 15.2 (150) (168,3) (88,9) (5,1) (165,1) (6,9) 8 8.6 4.25 20.6 7.8 29.6 (200) (219,1) (108,0) (9,3) (196,9) (13,4) 267,4mm 10.52 9.00 45.69 — — (250) (267,4) (228,6) (20,72) 10 10.750 4.75 30.1 9.00 52.0 (250) (273,0) (120,7) (13,7) (228,6) (23,6) 318,5mm 12.54 10.00 61.86 — — (300) (318,5) (254,0) (21,86) 12 12.750 5.25 48.0 10.00 66.4 (300) (323,9) (133,4) (22,0) (254,0) (30,1) FIGURE 2 FIGURES 501 AND 510 ELBOWS NOMINAL DIMENSIONS TFP1815 Page 6 of 26 Figure 519 Figure 260(a) Nominal Pipe Size Cast Tee Cast End Cap Nominal Approx. Nominal Approx. ANSI O.D. C to E Weight E to E Weight Inches Inches Inches Lbs. Inches Lbs. (DN) (mm) (mm) (kg) (mm) (kg) 1 1.3 2.25 1.1 0.8 0.2 (25) (33,4) (57,2) (0,5) (21,1) (0,1) 1-1/4 1.7 2.8 1.7 0.8 0.3 (32) (42,4) (69,9) (0,8) (21,1) (0,1) C to E 1-1/2 1.9 2.8 2.1 0.8 0.4 (40) (48,3) (69,9) (1,00) (21,1) (0,2) 2 2.4 3.3 2.8 0.9 0.7 (50) (60,3) (82,6) (1,3) (23,4) (0,3) 2-1/2 2.9 3.8 4.4 0.9 1.0 (65) (73,0) (95,3) (2,0) (23,4) (0,5) C to E 76,1mm 3.0 3.8 4.5 0.9 1.3 FIGURE 519 (65) (76,1) (95,3) (2,0) (21,8) (0,6) CAST TEE 3 3.5 4.3 6.5 0.9 1.4 E to E (80) (88,9) (108,0) (3,0) (23,4) (0,6) 4 4.5 5.0 9.5 1.0 2.6 (100) (114,3) (127,0) (4,3) (25,4) (1,2) 139,7mm 5.5 5.5 13.9 0.9 4.7 (125) (139,7) (139,7) (6,3) (23,4) (2,1) FIGURE 260a 5 5.6 5.0 14.2 1.0 5.0 CAST END CAP (125) (141,3) (127,0) (6,4) (25,4) (2,3) 165,1mm 6.5 6.5 19.7 0.9 6.4 (150) (165,1) (165,1) (8,9) (23,4) (2,9) 6 6.6 6.5 22.4 1.0 6.2 (150) (168,3) (165,1) (10,2) (25,4) (2,8) 216,3mm 8.52 1.06 11.02 — — (200) (216,3) (27,0) (4,99) 8 8.6 7.8 39.8 1.1 7.1 (200) (219,1) (196,9) (18,1) (27,0) (3,2) 267,4mm 10.52 9.00 62.58 1.02 19.05 (250) (267,4) (228,6) (28,39) (25,78) (8,64) 10 10.8 9.00 64.2 1.0 24.5 (250) (273,0) (228,6) (29,1) (25,8) (11,1) 318,5mm 12.54 10.00 82.79 1.02 28.82 (300) (318,5) (254,0) (37,55) (25,8) (13,07) 12 12.8 10.00 110.0 1.02 31.0 (300) (323,9) (254,0) (49,9) (25,8) (14,1) NOTES a. Available with tapped plugs. Contact Johnson Controls. FIGURE 3 FIGURES 519 TEE AND FIGURE 260 END CAP NOMINAL DIMENSIONS TFP1815 Page 7 of 26 Figure 510S Figure 519S Nominal Pipe Size 90° Elbow Tee Nominal Approx. Nominal Approx. ANSI O.D. C to E Weight C to E Weight Inches Inches Inches Lbs. Inches Lbs. (DN) (mm) (mm) (kg) (mm) (kg) 2 2.4 2.8 1.5 2.8 2.6 (50) (60,3) (69,9) (0,7) (69,9) (1,2) 2-1/2 2.9 3.0 2.1 3.0 4.4 C to E (65) (73,0) (76,2) (1,0) (76,2) (2,0) FIGURE 510S 76,1mm 3.0 3.0 2.3 3.0 3.1 90° ELBOW (65) (76,1) (76,2) (1,0) (76,2) (1,4) SHORT PATTERN 3 3.5 3.4 3.0 3.8 6.5 (80) (88,9) (85,9) (1,4) (85,9) (3,0) C to E 4 4.5 4.0 5.0 4.0 10.7 (100) (114,3) (101,6) (2,3) (101,6) (4,9) 139,7mm 5.5 4.9 8.7 4.9 10.9 (125) (139,7) (124,0) (3,9) (124,0) (5,0) 5 5.6 4.8 9.4 4.8 11.6 C to E (125) (141,3) (123,0) (4,3) (123,0) (5,3) FIGURE 519S 165,1mm 6.5 5.5 11.4 5.5 14.8 TEE (150) (165,1) (139,7) (5,2) (139,7) (6,7) SHORT PATTERN 6 6.6 5.5 12.1 5.5 15.0 (150) (168,3) (139,7) (5,5) (139,7) (6,8) 8 8.6 6.9 22.2 6.9 39.8 (200) (219,1) (174,8) (10,1) (174,8) (18,1) FIGURE 4 FIGURES 510S ELBOW AND FIGURE 519S TEE NOMINAL DIMENSIONS TFP1815 Page 8 of 26 Figure 510DE(a) Nominal Pipe Size 90° Drain Elbow Nominal Nominal Nominal Approx. ANSI O.D. C to E A B Weight Inches Inches Inches Inches Inches Lbs. (DN) (mm) (mm) (mm) (mm) (kg) 1" NPT 2 2.4 3.8 2.0 2.8 3.1 (50) (60,3) (95,3) (50,8) (69,9) (1,4) 2-1/2 2.9 3.8 2.0 2.8 2.2 B (65) (73,0) (95,3) (50,8) (69,9) (1,0) 3 3.5 4.3 2.3 2.8 6.0 A (80) (88,9) (108,0) (59,4) (69,9) (2,7) C to E 4 4.5 5.0 2.9 2.8 8.6 (100) (114,3) (127,0) (72,4) (69,9) (3,9) 6 6.6 6.5 3.9 2.8 18.0 (150) (168,3) (165,1) (99,6) (69,9) (8,2) 8 8.6 7.8 5.00 2.8 31.0 (200) (219,1) (196,9) (125,7) (69,9) (14,1) NOTES a. Figure 510DE not available for the EMEA market. FIGURE 5 FIGURE 510DE 90° DRAIN ELBOW NOMINAL DIMENSIONS Nominal Pipe Dimensions- Inches Size (mm) Approx. Weight ANSI Lbs. Outlet A B Inches C D (kg) NPT(1) O.D. Takeout (DN) 1.3 1.8 1.9 0.8 1/2 (31,8) (44,5) (48,0) (0,4) 1-1/2 1.9 1.3 1.8 1.9 0.8 D NPT 3/4 C (40) (48,3) (31,8) (44,5) (48,0) (0,4) 1.4 2.0 2.0 0.9 1 (34,8) (50,8) (51,3) (0,4) B 1.3 1.8 1.9 0.9 1/2 A (31,8) (44,5) (48,0) (0,4) 2 2.4 1.3 1.8 1.9 0.8 3/4 (50) (60,3) (31,8) (44,5) (48,0) (0,4) 1.4 2.0 2.0 1.1 1 (34,8) (50,8) (51,3) (0,5) 1.5 2.0 1.9 1.8 1/2 (37,3) (50,0) (48,0) (0,8) 2-1/2 2.9 1.5 2.0 1.9 1.1 3/4 (65) (73,0) (37,3) (50,0) (48,0) (0,5) 1.4 2.0 2.0 1.1 1 (34,8) (50,8) (51,3) (0,5) NOTES a. ISO threaded outlets are available upon request. b. ADACAP not available for the EMEA market. c. Rated pressure 300 psi (20,7 bar). FIGURE 6 ADACAP NOMINAL DIMENSIONS TFP1815 Page 9 of 26 Figure 320 Nominal Pipe Size Fabricated Thread Tee Nominal Nominal Approx. ANSI O.D. C to GE C to TE Weight Inches Inches Inches Inches Lbs. (DN) (mm) (mm) (mm) (kg) 1 1.31 2.25 2.25 1.3 (25) (33,4) (57,2) (57,2) (0,6) 1-1/4 1.66 2.75 2.75 1.5 (32) (42,4) (69,9) (69,9) (0,7) 1-1/2 1.90 2.75 2.75 1.9 (40) (48,3) (69,9) (69,9) (0,9) 2 2.37 3.25 4.25 3.2 (50) (60,3) (82,6) (108,0) (1,5) 2-1/2 2.87 3.75 3.75 4.0 (65) (73,0) (95,3) (95,3) (1,8) C to TE 76,1mm 3.00 3.75 3.75 4.5 (65) (76,1) (95,3) (95,3) (2,0) 3 3.50 4.25 6.00 6.0 (80) (88,9) (108,0) (152,4) (2,7) 4 4.50 5.00 7.25 11.0 C to GE (100) (114,3) (127,0) (184,2) (5,0) 139,7mm 5.50 5.50 5.50 21.0 (125) (139,7) (139,7) (139,7) (9,5) 5 5.56 5.50 5.50 23.0 (125) (141,3) (139,7) (139,7) (10,5) 165,1mm 6.50 6.50 6.50 25 (150) (165,1) (165,1) (165,1) (11,3) 6 6.63 6.50 6.50 28.0 (150) (168,3) (165,1) (165,1) (12,7) 8 8.63 7.75 7.75 38.7 (200) (219,1) (196,9) (196,9) (17,6) 10 10.75 9.00 9.00 72.1 (250) (273,0) (228,6) (228,6) (32,8) 12 12.75 10.00 10.00 92.5 (300) (323,9) (254,0) (254,0) (42,0) NOTES a. Figure 320 not available for the EMEA market. FIGURE 7 FIGURE 320 FABRICATED GROOVE X GROOVE X MALE THREAD TEES (SEGMENT WELDED) NOMINAL DIMENSIONS TFP1815 Page 10 of 26 Figure 221 Figure 321 Nominal Pipe Size Cast Fabricated Reducing Tee Reducing Tee Nominal Approx. Nominal Approx. O.D. ANSI Inches C to E Weight C to E Weight Inches (DN) Inches Lbs. Inches Lbs. (mm) (mm) (kg) (mm) (kg) 1-1/4 x 1-1/4 x 1 1.66 x 1.66 x 1.31 2.75 1.3 — — (32 x 32 x 25) (42,4 x 42,4 x 33,4) (69,9) (0,6) 1-1/2 x 1-1/2 x 1 1.90 x 1.90 x 1.31 2.75 1.4 — — (40 x 40 x 25) (48,3 x 48,3 x 33,4) (69,9) (0,6) 1-1/2 x 1-1/2 x 1-1/4 1.90 x 1.90 x 1.66 2.75 1.5 — — (40 x 40 x 32) (48,3 x 48,3 x 42,4) (69,9) (0,7) 2 x 2 x 1 2.37 x 2.37 x 1.32 3.25 1.6 — — (50 x 50 x 25) (60,3 x 60,3 x 33,4) (82,6) (0,7) 2 x 2 x 1-1/2 2.37 x 2.37 x 1.90 3.25 2.7 3.25 2.0 (50 x 50 x 40) (60,3 x 60,3 x 48,3) (82,6) (1,2) (82,6) (0,9) 2-1/2 x 2-1/2 x 1 2.87 x 2.87 x 1.32 3.75 2.3 — — (65 x 65 x 25) (73,0 x 73,0 x 33,4) (95,3) (1,1) C to E 2-1/2 x 2-1/2 x 1-1/4 2.87 x 2.87 x 1.66 3.75 4.2 — — (65 x 65 x 32) (73,0 x 73,0 x 42,4) (95,3) (1,9) 2-1/2 x 2-1/2 x 1-1/2 2.87 x 2.87 x 1.90 3.75 4.2 — — (65 x 65 x 40) (73,0 x 73,0 x 48,3) (95,3) (1,9) 2-1/2 x 2-1/2 x 2 2.87 x 2.87 x 2.37 3.75 4.2 3.75 4.5 C to E (65 x 65 x 50) (73,0 x 73,0 x 60,3) (95,3) (1,9) (95,3) (2,0) FIGURE 221 76,1mm x 76,1mm x 1 3.00 x 3.00 x 1.32 — — 3.75 2.4 CAST TEE REDUCING (65 x 65 x 25) (76,1 x 76,1 x 33,4) (95,3) (1,1) GROOVED 76,1mm x 76,1mm x 1-1/4 3.00 x 3.00 x 1.66 3.75 4.3 (SEGMENT WELDED) — — (65 x 65 x 32) (76,1 x 76,1 x 42,4) (95,3) (2,0) C to E 76,1mm x 76,1mm x 1-1/2 3.00 x 3.00 x 1.90 3.75 4.5 3.75 4.2 (65 x 65 x 40) (76,1 x 76,1 x 48,3) (95,3) (2,0) (95,3) (1,9) 76,1mm x 76,1mm x 2 3.00 x 3.00 x 2.37 3.75 4.3 3.75 4.6 (65 x 65 x 50) (76,1 x 76,1 x 60,3) (95,3) (2,0) (95,3) (2,1) 3 x 3 x 1 3.50 x 3.50 x 1.32 4.25 5.6 4.25 6.0 C to E (80 x 80 x 25 (88,9 x 88,9 x 33,4) (108,0) (2,5) (108,0) (2,7) FIGURE 321 3 x 3 x 1-1/4 3.50 x 3.50 x 1.66 — — 4.25 6.1 FABRICATED TEE REDUCING (80 x 80 x 32) (88,9 x 88,9 x 42,4) (108,0) (2,8) GROOVED 3 x 3 x 1-1/2 3.50 x 3.50 x 1.90 4.25 5.9 4.25 6.2 (SEGMENT WELDED) (80 x 80 x 40) (88,9 x 88,9 x 48,3) (108,0) (2,7) (108,0) (2,8) 3 x 3 x 2 3.50 x 3.50 x 2.37 4.25 6.0 4.25 6.4 (80 x 80 x 50) (88,9 x 88,9 x 60,3) (108,0) (2,7) (108,0) (2,9) 3 x 3 x 2-1/2 3.50 x 3.50 x 2.87 4.25 6.2 4.25 6.5 (80 x 80 x 65) (88,9 x 88,9 x 73,0) (108,0) (2,8) (108,0) (2,9) 3 x 3 x 76,1mm 3.50 x 3.50 x 3.00 4.25 6.0 4.25 6.7 (80 x 80 x 65) (88,9 x 88,9 x 76,1) (108,0) (2,7) (108,0) (3,0) 4 x 4 x 1 4.50 x 4.50 x 1.32 5.00 8.0 — — (100 x 100 x 25) (114,3 x 114,3 x 33,4) (127,0) (3,7) 4 x 4 x 1-1/4 4.50 x 4.50 x 1.66 5.00 9.8 — — (100 x 100 x 32) (114,3 x 114,3 x 42,4) (127,0) (4,4) 4 x 4 x 1-1/2 4.50 x 4.50 x 1.90 5.00 9.9 — — (100 x 100 x 40) (114,3 x 114,3 x 48,3) (127,0) (4,5) 4 x 4 x 2 4.50 x 4.50 x 2.37 5.00 9.1 5.00 11.0 (100 x 100 x 50) (114,3 x 114,3 x 60,3) (127,0) (4,1) (127,0) (5,0) 4 x 4 x 2-1/2 4.50 x 4.50 x 2.88 5.00 9.5 5.00 11.2 (100 x 100 x 65) (114,3 x 114,3 x 73,0) (127,0) (4,3) (127,0) (5,1) 4 x 4 x 76,1mm 4.50 x 4.50 x 3.00 5.00 9.5 5.00 11.4 (125 x 125 x 65) (114,3 x 114,3 x 76,1) (127,0) (4,3) (127,0 (5,2) FIGURE 8 (1 OF 3) FIGURES 221 AND 321 REDUCING TEES NOMINAL DIMENSIONS TFP1815 Page 11 of 26 Figure 221 Figure 321 Nominal Pipe Size Cast Fabricated Reducing Tee Reducing Tee Nominal Approx. Nominal Approx. O.D. ANSI Inches C to E Weight C to E Weight Inches (DN) Inches Lbs. Inches Lbs. (mm) (mm) (kg) (mm) (kg) 4 x 4 x 3 4.50 x 4.50 x 3.50 5.00 9.7 5.00 11.6 (100 x 100 x 80) (114,3 x 114,3 x 88,9) (127,0) (4,4) (127,0 (5,3) 139,7mm x 139,7mm x 3 5.50 x 5.50 x 3.50 5.50 12.7 5.50 12.2 (125 x 125 x 80) (139,7 x 139,7 x 88,9) (139,7) (5,8) (139,7) (5,5) 139,7mm x 139,7mm x 4 5.50 x 5.50 x 4.50 5.50 13.4 5.50 12.5 (125 x 125 x 100) (139,7 x 139,7 x 114,3) (139,7) (6,1) (139,7) (5,7) 5 x 5 x 1 5.56 x 5.56 x 1.31 5.50 13.0 — — (125 x 125 x 25) (141,3 x 141,3 x 33,4) (139,7) (5,9) 5 x 5 x 1-1/2 5.56 x 5.56 x 1.90 5.50 13.4 — — (125 x 125 x 40) (141,3 x 141,3 x 48,3) (139,7) (6,1) 5 x 5 x 2 5.56 x 5.56 x 2.37 5.50 14.1 — — (125 x 125 x 50) (141,3 x 141,3 x 60,3) (139,7) (6,4) 5 x 5 x 2-1/2 5.56 x 5.56 x 2.87 5.50 18.0 5.50 14.8 C to E (125 x 125 x 65) (141,3 x 141,3 x 73,0) (139,7) (8,2) (139,7) (6,7) 5 x 5 x 76,1mm 5.56 x 5.56 x 3.00 5.50 15.3 — — (125 x 125 x 65) (141,3 x 141,3 x 76,1) (139,7) (6,9) 5 x 5 x 3 5.56 x 5.56 x 3.50 5.50 14.0 5.50 16.0 (125 x 125 x 80) (141,3 x 141,3 x 88,9) (139,7) (6,4) (139,7) (7,3) C to E 5 x 5 x 4 5.56 x 5.56 x 4.50 5.50 13.9 5.50 16.4 FIGURE 221 (125 x 125 x 100) (141,3 x 141,3 x 114,3) (139,7) (6,3) (139,7) (7,4) CAST TEE REDUCING GROOVED 165,1mm x 165,1mm x 3 6.50 x 6.50 x 3.50 6.50 18.0 6.50 22.0 (SEGMENT WELDED) (150 x 150 x 80) (165,1 x 165,1 x 88,9) (165,1) 8,2 (165,1) (10,0) 165,1mm x 165,1mm x 4 6.50 x 6.50 x 4.50 6.50 19.5 6.50 22.6 C to E (150 x 150 x 100) (165,1 x 165,1 x 114,3) (165,1) 8,9 (165,1) (10,3) 165,1mm x 165,1mm x 5 6.50 x 6.50 x 5.50 6.50 23.2 — — (150 x 150 x 125) (165,1 x 165,1 x 139,7) (165,1) (10,5) 165,1mm x 165,1mm x 139,7mm 6.50 x 6.50 x 5.50 6.50 22.9 — — (150 x 150 x 125) (165,1 x 165,1 x 141,3) (165,1) (10,4) C to E 6 x 6 x 1 6.63 x 6.63 x 1.31 6.50 22.8 — — FIGURE 321 (150 x 150 x 25) (168,3 x 168,3 x 33,4) (165,1) (10,3) FABRICATED TEE REDUCING 6 x 6 x 1-1/2 6.63 x 6.63 x 1.90 6.50 22.9 GROOVED — — (SEGMENT WELDED) (150 x 150 x 40) (168,3 x 168,3 x 48,3) (165,1) (10,4) 6 x 6 x 2 6.63 x 6.63 x 2.37 6.50 19.4 6.50 23.0 (150 x 150 x 50) (168,3 x 168,3 x 60,3) (165,1) (8,8) (165,1) (10,4) 6 x 6 x 2-1/2 6.63 x 6.63 x 2.87 6.50 21.2 6.50 23.4 (150 x 150 x 65) (168,3 x 168,3 x 73,0) (165,1) (9,8) (165,1) (10,6) 6 x 6 x 76,1mm 6.63 x 6.63 x 3.00 6.50 21.2 6.50 23.5 (150 x 150 x 65) (168,3 x 168,3 x 76,1) (165,1) 9,8 (165,1) (10,7) 6 x 6 x 3 6.63 x 6.63 x 3.50 6.50 21.0 6.50 23.7 (150 x 150 x 80) (168,3 x 168,3 x 88,9) (165,1) (9,5) (165,1) (10,7) 6 x 6 x 4 6.63 x 6.63 x 4.50 6.50 21.8 6.50 23.9 (150 x 150 x 100) (168,3 x 168,3 x 114,3) (165,1) (9,9) (165,1) (10,8) 6 x 6 x 139,7mm 6.63 x 6.63 x 5.50 6.50 23.0 6.50 24.0 (150 x 150 x 125) (168,3 x 168,3 x 139,7) (165,1) 10,4 (165,1) (10,9) 6 x 6 x 5 6.63 x 6.63 x 5.56 6.50 27.0 — — (150 x 150 x 125) (168,3 x 168,3 x 141,3) (165,1) 12,2 8 x 8 x 1-1/2 8.63 x 8.63 x 1.90 7.75 36.0 — — (200 x 200 x 40) (219,1 x 219,1 x 48,3) (196,9 (16,3) 8 x 8 x 2 8.63 x 8.63 x 2.375 7.75 36.2 — — (200 x 200 x 50) (219,1 x 219,1 x 60,3) (196,9) (16,4) FIGURE 8 (2 OF 3) FIGURES 221 AND 321 REDUCING TEES NOMINAL DIMENSIONS TFP1815 Page 12 of 26 Figure 221 Figure 321 Nominal Pipe Size Cast Fabricated Reducing Tee Reducing Tee Nominal Approx. Nominal Approx. O.D. ANSI Inches C to E Weight C to E Weight Inches (DN) Inches Lbs. Inches Lbs. (mm) (mm) (kg) (mm) (kg) 8 x 8 x 2-1/2 8.63 x 8.63 x 2.88 7.75 36.4 — — (200 x 200 x 65) (219,1 x 219,1 x 73,0) (196,9) (16,5) 216mm x 216mm x 165,1mm 8.52 x 8.52 x 6.50 7.75 37.9 — — (200 x 200 x 150) (216,3 x 216,3 x 165,1) (196,9) (17,2) 8 x 8 x 76,1mm 8.63 x 8.63 x 3.00 7.75 36.4 — — (200 x 200 x 65) (216,1 x 219,1 x 76.1) (196,9) (16,5) 8 x 8 x 3 8.63 x 8.63 x 3.50 7.75 36.5 — — (200 x 200 x 80) (219,1 x 219,1 x 88,9) (196,9) (16,6) 8 x 8 x 4 8.63 x 8.63 x 4.50 7.75 37.2 7.75 36.4 (200 x 200 x 100) (219,1 x 219,1 x 114,1) (196,9) (16,9) (196,9) (16,5) 8 x 8 x 139,7mm 8.63 x 8.63 x 5.56 7.75 37.7 7.75 36.7 C to E (200 x 200 x 125) (219,1 x 219,1 x 139,7) (196,9) (17,1) (196,9) (16,6) 8 x 8 x 5 8.63 x 8.63 x 5.50 7.75 36.8 — — (200 x 200 x 125) (219,1 x 219,1 x 141,3) (196,9) (16,7) 8 x 8 x 165,1mm 8.63 x 8.63 x 6.50 7.75 37.7 7.75 39.0 (200 x 200 x 150) (219,1 x 219,1 x 165,1) (196,9) (17,1) (196,9) (17,7) C to E 10 x 10 x 1-1/2 10.75 x 10.75 x 1.90 9.00 57.0 — — (250 x 250 x 40) (273,0 x 273,0 x 48,3) (228,6) (25,8) FIGURE 221 CAST TEE REDUCING 10 x 10 x 2 10.75 x 10.75 x 2.37 9.00 57.1 GROOVED (250 x 250 x 50) (273,0 x 273,0 x 60,3) — — (228,6) (25,9) (SEGMENT WELDED) 10 x 10 x 2-1/2 10.75 x 10.75 x 2.87 9.00 57.3 — — C to E (250 x 250 x 65) (273,0 x 273,0 x 73,0) (228,6) (26,0) 10 x 10 x 3 10.75 x 10.75 x 3.50 9.00 57.4 — — (250 x 250 x 80) (273,0 x 273,0 x 88,9) (228,6) (26,0) 10 x 10 x 4 10.75 x 10.75 x 4.50 9.00 57.8 — — (250 x 250 x 100) (273,0 x 273,0 x 114,3) (228,6) (26,2) C to E 10 x 10 x 5 10.75 x 10.75 x 5.56 9.00 58.0 — — (250 x 250 x 125) (273,0 x 273,0 x 141,3) (228,6) (26,3) FIGURE 321 FABRICATED TEE REDUCING 10 x 10 x 6 10.75 x 10.75 x 6.63 9.00 62.0 GROOVED (250 x 250 x 150) (273,0 x 273,0 x 168,3) — — (228,6) (28,1) (SEGMENT WELDED) 10 x 10 x 8 10.75 x 10.75 x 8.63 9.00 63.0 — — (250 x 250 x 200) (273,0 x 273,0 x 219,1) (228,6) (28,6) 12 x 12 x 1 12.75 x 12.75 x 1.31 10.00 64.0 — — (300 x 300 x 25) (323,9 x 323,9 x 33,4) (254,0) (29,0) 12 x 12 x 2 12.75 x 12.75 x 2.37 10.00 69.5 — — (300 x 300 x 50) (323,9 x 323,9 x 60,3) (254,0) (31,5) 12 x 12 x 2-1/2 12.75 x 12.75 x 2.87 10.00 75.6 — — (300 x 300 x 65) (323,9 x 323,9 x 73,0) (254,0) (34,3) 12 x 12 x 3 12.75 x 12.75 x 3.50 10.00 80.2 — — (300 x 300 x 80) (323,9 x 323,9 x 88,9) (254,0) (36,4) 12 x 12 x 4 12.75 x 12.75 x 4.50 10.00 80.5 — — (300 x 300 x 100) (323,9 x 323,9 x 114,3) (254,0) (36,5) 12 x 12 x 5 12.75 x 12.75 x 5.56 10.00 80.7 — — (300 x 300 x 125) (323,9 x 323,9 x 141,3) (254,0) (36,6) 12 x 12 x 6 12.75 x 12.75 x 6.63 10.00 80.9 — — (300 x 300 x 150) (323,9 x 323,9 x 168,3) (254,0) (36,7) 12 x 12 x 165,1mm 12.75 x 12.75 x 6.50 10.00 79.9 — — (300 x 300 x 150) (323,9 x 323,9 x 165,1) (254,0) (36,2) 12 x 12 x 8 12.75 x 12.75 x 8.63 10.00 76.3 — — (300 x 300 x 200) (323,9 x 323,9 x 219,1) (254,0) (34,6) 12 x 12 x 10 12.75 x 12.75 x 10.75 10.00 77.6 — — (300 x 300 x 250) (323,9 x 323,9 x 273,0) (254,0) (35,2) FIGURE 8 (3 OF 3) FIGURES 221 AND 321 REDUCING TEES NOMINAL DIMENSIONS TFP1815 Page 13 of 26 Nominal Pipe Figure 327(a) Figure 341(a) Figure 342(a) Size Nominal Approx. Nominal Mating Approx. Nominal Mating Approx. ANSI O.D. C to E Weight E to E Flange Weight E to E Flange Weight Inches Inches Inches Lbs. Inches Bolt Lbs. Inches Bolt Lbs. (DN) (mm) (mm) (kg) (mm) Qty. (kg) (mm) Qty. (kg) 1 1.31 2.25 2.2 3.00 2.3 3.00 4.0 (25) (33,4) (57,2) (1,0) (76,2) 4 (1,0) (76,2) 4 (1,8) C to E 1-1/4 1.66 2.75 2.2 4.00 2.8 4.00 4.6 4 4 (32) (42,4) (69,9) (1,0) (101,6) (1,3) (101,6) (2,1) 1-1/2 1.90 2.75 2.5 4.00 3.2 4.00 7.1 4 4 (40) (48,3) (69,9) (1,1) (101,6) (1,5) (101,6) (3,2) C to E 2 2.37 3.25 3.7 4.00 5.2 4.00 8.2 4 8 (50) (60,3) (82,6)b (1,7)b (101,6) (2,4) (101,6) (3,7) FIGURE 327a FABRICATED CROSS 2-1/2 2.87 3.75 5.8 4.00 8.0 4.00 11.9 4 8 GROOVED (65) (73,0) (95,3)b (2,6)b (101,6) (3,6) (101,6) (5,4) (SEGMENT WELDED) 76,1mm 3.00 3.75 6.0 4.00 8.8 4.00 12.5 4 8 (65) (76,1) (95,3) (2,7) (101,6) (4,0) (101,6) (5,7) E to E 3 3.50 4.25 8.6 4.00 10.2 4.00 15.5 4 8 (80) (88,9) (108,0) (3,9) (101,6) (4,6) (101,6) (7,0) 4 4.50 5.00 20.7 6.00 17.2 6.00 28.0 8 8 (100) (114,3) (127,0)b (9,4)b (152,4) (7,8) (152,4) (12,7) 139,7mm 5.50 5.50 18.3 6.00 18.5 6.00 32.5 8 8 (125) (139,7) (139,7) (8,3) (152,4) (8,4) (152,4) (14,7) FIGURE 341a 5 5.56 5.50 18.5 6.00 21.4 6.00 37.0 8 8 FABRICATED (125) (141,3) (139,7) (8,4) (152,4) (9,7) (152,4) (16,8) FLANGE ADAPTER 165,1mm 6.50 6.50 26.2 6.00 22.0 6.00 42.5 ANSI CLASS 150 LBS. 8 12 GROOVED (150) (165,1) (165,1) (11,9) (152,4) (10,0) (152,4) (19,3) 6 6.63 6.50 27.3 6.00 26.0 6.00 48.0 FIGURE 342a 8 12 (150) (168,3) (165,1) (12,4) (152,4) (11,8) (152,4) (21,8) FABRICATED FLANGE ADAPTER 216,3mm 8.52 7.75 44.0 6.00 34.5 6.00 72.5 ANSI CLASS 300 LBS. 8 12 (200) (216,3) (196,9) (20,0) (152,4) (15,6) (152,4) (32,9) GROOVED 8 8.63 7.75 48.0 6.00 38.4 6.00 79.0 8 12 (200) (219,1) (196,9) (21,7) (152,4) (17,4) (152,4) (35,8) 10 10.75 9.00 75.0 8.00 65.0 8.00 122.0 12 16 (250) (273,0) (228,6) (34,0) (203,2) (29,5) (203,2) (55,3) 12 12.75 10.00 95.8 8.00 91.0 8.00 183.0 12 16 (300) (323,9) (254,0) (43,4) (203,2) (41,3) (203,2) (83,0) NOTES a. Figure 327, Figure 341, and Figure 342 are not available for the EMEA market. b. Figure 227 FIGURE 9 FIGURE 327 CROSS AND FIGURE 341 AND FIGURE 342 FLANGE ADAPTERS NOMINAL DIMENSIONS TFP1815 Page 14 of 26 Nominal Pipe Size Nominal Approx. C to E Weight O.D. Inches Lbs. ANSI Inches Inches (mm) (kg) (DN) (mm) 2 x 2 x 3/4 2.37 x 2.37 x 1.05 3.25 2.0 (50 x 50 x 20) (60,3 x 60,3 x 26,7) (82,6) (0,9) 2 x 2 x 1 2.37 x 2.37 x 1.31 3.25 2.2 (50 x 50 x 25) (60,3 x 60,3 x 33,4) (82,6) (1,0) 2 x 2 x 1-1/4 2.37 x 2.37 x 1.66 3.25 2.3 (50 x 50 x 32) (60,3 x 60,3 x 42,4) (82,6) (1,0) 2 x 2 x 1-1/2 2.37 x 2.37 x 1.90 3.25 1.4 (50 x 50 x 40) (60,3 x 60,3 x 48,3) (82,6) (1,1) 2-1/2 x 2-1/2 x 1 2.875 x 2.875 x 1.315 3.75 3.6 (65 x 65 x 25) (73,0 x 73,0 x 33,4) (95,3) (1,6) 2-1/2 x 2-1/2 x 1-1/4 2.875 x 2.875 x 1.660 3.75 3.8 (65 x 65 x 32) (73,0 x 73,0 x 42,4) (95,3) (1,7) 2-1/2 x 2-1/2 x 1-1/2 2.875 x 2.875 x 1.900 3.75 4.0 (65 x 65 x 40) (73,0 x 73,0 x 48,3) (95,3) (1,8) 2-1/2 x 2-1/2 x 2 2.875 x 2.875 x 2.375 3.75 4.2 (65 x 65 x 50) (73,0 x 73,0 x 60,3) (95,3) (1,9) 76,1mm x 76,1mm x 1 3.00 x 3.00 x 1.31 3.75 3.8 (65 x 65 x 25) (76,1 x 76,1 x 33,4) (95,3) (1,7) C to E 76,1mm x 76,1mm x 1-1/4 3.00 x 3.00 x 1.66 3.75 4.0 (65 x 65 x 32) (76,1 x 76,1 x 42,4) (95,3) (1,8) 76,1mm x 76,1mm x 1-1/2 3.00 x 3.00 x 1.90 3.75 4.2 (65 x 65 x 40) (76,1 x 76,1 x 48,3) (95,3) (1,9) 3 x 3 x 3/4 3.50 x 3.50 x 1.05 4.25 5.2 C to E (80 x 80 x 20) (88,9 x 88,9 x 26,7) (108,0) (2,4) 3 x 3 x 1 3.50 x 3.50 x 1.31 4.25 5.7 (80 x 80 x 25) (88,9 x 88,9 x 33,4) (108,0) (2,6) 3 x 3 x 1-1/2 3.50 x 3.50 x 1.90 4.25 5.8 (80 x 80 x 40) (88,9 x 88,9 x 48,3) (108,0) (2,6) 3 x 3 x 2 3.50 x 3.50 x 2.37 4.25 5.9 (80 x 80 x 50) (88,9 x 88,9 x 60,3) (108,0) (2,7) 3 x 3 x 2-1/2 3.50 x 3.50 x 2.87 4.25 6.3 (80 x 80 x 65) (88,9 x 88,9 x 73,0) (108,0) (2,9) 3 x 3 x 76,1mm 3.50 x 3.50 x 3.00 4.25 6.5 (80 x 80 x 65) (88,9 x 88,9 x 76,1) (108,0) (2,9) 4 x 4 x 3/4 4.50 x 4.50 x 1.05 3.75 6.4 (100 x 100 x 20) (114,3 x 114,3 x 26,7) (95,3) (2,9) 4 x 4 x 1 4.50 x 4.50 x 1.31 5.00 6.9 (100 x 100 x 25) (114,3 x 114,3 x 33,4) (127,0) (3,1) 4 x 4 x 1-1/4 4.50 x 4.50 x 1.66 5.00 7.6 (100 x 100 x 32) (114,3 x 114,3 x 42,4) (127,0) (3,4) 4 x 4 x 1-1/2 4.50 x 4.50 x 1.90 5.00 8.3 (100 x 100 x 40) (114,3 x 114,3 x 48,3) (127,0) (3,8) 4 x 4 x 2 4.50 x 4.50 x 2.37 5.00 9.6 (100 x 100 x 50) (114,3 x 114,3 x 60,3) (127,0) (4,4) 4 x 4 x 2-1/2 4.500 x 4.500 x 2.875 5.00 10.0 (100 x 100 x 65) (114,3 x 114,3 x 73,0) (127,0) (4,5) 4 x 4 x 76,1mm 4.500 x 4.500 x 3.00 5.00 10.5 (100 x 100 x 65) (114,3 x 114,3 x 76,1) (127,0) (4,8) NOTES a. Figure 323 not available for the EMEA market. FIGURE 10 (1 OF 3) FIGURE 323 FABRICATED GROOVE X GROOVE X MALE THREAD REDUCING TEES (SEGMENT WELDED) NOMINAL DIMENSIONS TFP1815 Page 15 of 26 Nominal Pipe Size Nominal Approx. C to E Weight O.D. Inches Lbs. ANSI Inches Inches (mm) (kg) (DN) (mm) 4 x 4 x 3 4.50 x 4.50 x 3.50 5.00 10.3 (100 x 100 x 80) (114,3 x 114,3 x 88,9) (127,0) (4,7) 5 x 5 x 2 5.56 x 5.56 x 2.37 5.50 14.0 (125 x 125 x 50) (141,3 x 141,3 x 60,3) (139,7) (6,4) 5 x 5 x 2-1/2 5.56 x 5.56 x 2.87 5.50 14.3 (125 x 125 x 65) (141,3 x 141,3 x 73,0) (139,7) (6,5) 5 x 5 x 76,1mm 5.56 x 5.56 x 3.00 5.50 14.5 (125 x 125 x 65) (141,3 x 141,3 x 76,1) (139,7) (6,6) 5 x 5 x 3 5.56 x 5.56 x 3.50 5.50 14.6 (125 x 125 x 80) (141,3 x 141,3 x 88,9) (139,7) (6,6) 5 x 5 x 4 5.56 x 5.56 x 4.50 5.50 15.1 (125 x 125 x 100) (141,3 x 141,3 x 114,3) (139,7) (6,8) 165,1mm x 165,1mm x 2 6.50 x 6.50 x 2.37 6.50 9.5 (150 x 150 x 50) (165,1 x 165,1 x 60,3) (165,1) (4,3) 165,1mm x 165,1mm x 2-1/2 6.50 x 6.50 x 2.875 6.50 9.7 (150 x 150 x 65) (165,1 x 165,1 x 73,0) (165,1) (4,4) 165,1mm x 165,1mm x 6.50 x 6.50 x 3.00 6.50 9.7 76,1mm (165,1 x 165,1 x 76,1) (165,1) (4,4) (150 x 150 x 65) C to E 165,1mm x 165,1mm x 3 6.50 x 6.50 x 3.50 6.50 9.8 (150 x 150 x 80) (165,1 x 165,1 x 88,9) (165,1) (4,4) 165,1mm x 165,1mm x 4 6.50 x 6.50 x 4.50 6.50 10.0 (150 x 150 x 100) (165,1 x 165,1 x 114,3) (165,1) (4,5) 165,1mm x 165,1mm x 5 6.50 x 6.50 x 5.563 6.50 10.2 (150 x 150 x 125) (165,1 x 165,1 x 141,3) (165,1) (4,6) C to E 6 x 6 x 1-1/2 6.625 x 6.625 x 1.90 6.50 19.0 (150 x 150 x 40) (168,3 x 168,3 x 48,3) (165,1) (8,6) 6 x 6 x 2 6.625 x 6.625 x 2.375 6.50 21.3 (150 x 150 x 50) (168,3 x 168,3 x 60,3) (165,1) (9,7) 6 x 6 x 2-1/2 6.625 x 6.625 x 2.875 6.50 21.7 (150 x 150 x 65) (168,3 x 168,3 x 73,0) (165,1) (9,8) 6 x 6 x 76,1mm 6.625 x 6.625 x 3.00 6.50 14.5 (150 x 150 x 65) (168,3 x 168,3 x 76,1) (165,1) (6,6) 6 x 6 x 3 6.625 x 6.625 x 3.500 6.50 22.0 (150 x 150 x 80) (168,3 x 168,3 x 88,9) (165,1) (10,0) 6 x 6 x 4 6.625 x 6.625 x 4.500 6.50 22.5 (150 x 150 x 100) (168,3 x 168,3 x 114,3) (165,1) (10.2) 6 x 6 x 5 6.625 x 6.625 x 5.563 6.50 23.1 (150 x 150 x 125) (168,3 x 168,3 x 141,3) (165,1) 10,5 8 x 8 x 2 8.63 x 8.63 x 2.37 7.75 32.7 (200 x 200 x 50) (219,1 x 219,1 x 60,3) (196,9) (14,8) 8 x 8 x 3 8.63 x 8.63 x 3.50 7.75 33.5 (200 x 200 x 80) (219,1 x 219,1 x 88,9) (196,9) (15,2) 8 x 8 x 4 8.63 x 8.63 x 4.50 7.75 34.5 (200 x 200 x 100) (219,1 x 219,1 x 114,1) (196,9) (15,6) 8 x 8 x 5 8.63 x 8.63 x 5.56 7.75 34.7 (200 x 200 x 125) (219,1 x 219,1 x 141,3) (196,9) (15,7) NOTES a. Figure 323 not available for the EMEA market. FIGURE 10 (2 OF 3) FIGURE 323 FABRICATED GROOVE X GROOVE X MALE THREAD REDUCING TEES (SEGMENT WELDED) NOMINAL DIMENSIONS TFP1815 Page 16 of 26 Nominal Pipe Size Nominal Approx. C to E Weight O.D. Inches Lbs. ANSI Inches Inches (mm) (kg) (DN) (mm) 8 x 8 x 165,1mm 8.63 x 8.63 x 6.50 7.75 35.0 (200 x 200 x 150) (219,1 x 219,1 x 165,1) (196,9) (15,9) 8 x 8 x 6 8.63 x 8.63 x 6.63 7.75 35.6 (200 x 200 x 150) (219,1 x 219,1 x 168,3) (196,9) (16,1) 10 x 10 x 2 10.75 x 10.75 x 2.37 9.00 52.2 (250 x 250 x 50) (273,0 x 273,0 x 60,3) (228,6) (23,7) 10 x 10 x 3 10.75 x 10.75 x 3.50 9.00 53.0 (250 x 250 x 80) (273,0 x 273,0 x 88,9) (228,6) (24,0) 10 x 10 x 4 10.75 x 10.75 x 4.50 9.00 53.6 C to E (250 x 250 x 100) (273,0 x 273,0 x 114,3) (228,6) (24,3) 10 x 10 x 5 10.75 x 10.75 x 5.56 9.00 54.2 (250 x 250 x 125) (273,0 x 273,0 x 141,3) (228,6) (24,6) 10 x 10 x 165,1mm 10.75 x 10.75 x 6.50 9.00 55.5 (250 x 250 x 150) (273,0 x 273,0 x 165,1) (228,6) (25,2) C to E 10 x 10 x 6 10.75 x 10.75 x 6.63 9.00 54.9 (250 x 250 x 150) (273,0 x 273,0 x 168,3) (228,6) (24,9) 10 x 10 x 8 10.75 x 10.75 x 8.63 9.00 55.3 (250 x 250 x 200) (273,0 x 273,0 x 219,1) (228,6) (25,1) 12 x 12 x 3 12.75 x 12.75 x 3.50 10.00 74.6 (300 x 300 x 80) (323,9 x 323,9 x 88,9) (254,0) (33,8) 12 x 12 x 4 12.75 x 12.75 x 4.50 10.00 75.1 (300 x 300 x 100) (323,9 x 323,9 x 141,3) (254,0) (34,1) 12 x 12 x 5 12.75 x 12.75 x 5.563 10.00 75.6 (300 x 300 x 125) (323,9 x 323,9 x 114,3) (254,0) (34,3) 12 x 12 x 165,1mm 12.75 x 12.75 x 6.50 10.00 76.2 (300 x 300 x 150) (323,9 x 323,9 x 165,1) (254,0) (34,6) 12 x 12 x 6 12.75 x 12.75 x 6.625 10.00 76.2 (300 x 300 x 150) (323,9 x 323,9 x 168,3) (254,0) (34,6) 12 x 12 x 8 12.750 x 12.750 x 8.625 10.00 76.3 (300 x 300 x 200) (323,9 x 323,9 x 219,1) (254,0) (34,6) 12 x 12 x 10 12.750 x 12.750 x 10.750 10.00 77.6 (300 x 300 x 250) (323,9 x 323,9 x 273,0) (254,0) (35,2) NOTES a. Figure 323 not available for the EMEA market. FIGURE 10 (3 OF 3) FIGURE 323 FABRICATED GROOVE X GROOVE X MALE THREAD REDUCING TEES (SEGMENT WELDED) NOMINAL DIMENSIONS TFP1815 Page 17 of 26 Nominal Pipe Size Approx. E to E Weight Inches Pipe O.D. (mm) Lbs. ANSI Inches Inches (kg) (DN) (mm) 1-1/2 x 1 1.90 x 1.31 2.50 0.6 (40 x 25) (48,3 x 33,7) (63,5) (0,3) 2 x 3/4 2.37 x 1.05 2.50 1.0 (50 x 20) (60,3 x 26,7) (63,5) (0,5) 2 x 1 2.37 x 1.31 2.50 0.8 (50 x 25) (60,3 x 33,4) (63,5) (0,4) 2 x 1-1/4 2.37 x 1.66 2.50 0.8 (50 x 32) (60,3 x 42,4) (63,5) (0,4) 2 x 1-1/2 2.37 x 1.90 2.50 0.8 (50 x 40) (60,3 x 48,3) (63,5) (0,4) 2-1/2 x 1 2.87 x 1.31 2.50 0.9 (65 x 25) (73,0 x 33,4) (63,5) (0,4) 2-1/2 x 1-1/4 2.87 x 1.66 2.50 1.0 (65 x 32) (73,0 x 42,4) (63,5) (0,5) 2-1/2 x 1-1/2 2.87 x 1.90 2.50 1.3 (65 x 40) (73,0 x 48,3) (63,5) (0,6) 2-1/2 x 2 2.87 x 2.37 2.50 1.2 (65 x 50) (73,0 x 60,3) (63,5) (0,5) 76,1mm x 1-1/4 3.00 x 1.66 2.50 1.0 E to E (65 x 32) (76,1 x 42,4) (63,5) (0,5) 76,1mm x 1-1/2 3.00 x 1.90 2.50 1.1 (65 x 40) (76,1 x 48,3) (63,5) (0,5) 76,1mm x 2 3.00 x 2.37 2.50 1.2 (65 x 50) (76,1 x 60,3) (63,5) (0,5) 3 x 3/4 3.50 x 1.05 2.50 1.1 (80 x 20) (88,9 x 26,7) (63,5) (0,5) 3 x 1 3.50 x 1.31 2.50 1.3 (80 x 25) (88,9 x 33,4) (63,5) (0,6) 3 x 1-1/4 3.50 x 1.66 2.5 1.3 (80 x 32) (88,9 x 42,4) (63,5) (0,6) 3 x 1-1/2 3.50 x 1.90 2.50 1.3 (80 x 40) (88,9 x 48,3) (63.5) (0,6) 3 x 2 3.50 x 2.37 2.50 1.3 (80 x 50) (88,9 x 60,3) (63.5) (0,6) 3 x 2-1/2 3.50 x 2.87 2.50 1.5 (80 x 65) (88,9 x 73,0) (63.5) (0,7) 3 x 76,1mm 3.50 x 3.00 2.50 1.5 (80 x 65) (88,9 x 76,1) (63.5) (0,7) 4 x 1 4.50 x 1.31 3.00 1.8 (100 x 25) (114,3 x 33,4) (76,2) (0,8) 4 x 1-1/4 4.50 x 1.66 3.00 2.0 (100 x 32) (114,3 x 42,4) (76,2) (0,9) 4 x 1-1/2 4.50 x 1.90 3.00 2.3 (100 x 40) (114,3 x 48,3) (76,2) (1,0) 4 x 2 4.50 x 2.37 3.00 2.3 (100 x 50) (114,3 x 60,3) (76,2) (1,0) 4 x 2-1/2 4.50 x 2.87 3.00 2.3 (100 x 65) (114,3 x 73,0) (76,2) (1,0) NOTES a. Figure 372 not available for the EMEA market. FIGURE 11 (1 OF 2) FIGURE 372 FABRICATED CONCENTRIC REDUCER GROOVE X MALE THREAD (MPT) NOMINAL DIMENSIONS TFP1815 Page 18 of 26 Nominal Pipe Size Approx. E to E Weight Inches Pipe O.D. (mm) Lbs. ANSI Inches Inches (kg) (DN) (mm) 4 x 3 4.50 x 3.50 3.00 2.6 (100 x 80) (114,3 x 88,9) (76,2) (1,2) 5 x 4 5.56 x 4.50 3.50 4.5 (125 x 100) (141,3 x 114,3) (88,9) (2,0) 165,1mm x 1 6.50 x 1.31 4.00 1.2 (150 x 25) (165,1 x 33,4) (101,6) (0,5) 165,1mm x 2 6.50 x 2.37 4.00 5.5 (150 x 50) (165,1 x 60,3) (101,6) (2,5) 165,1mm x 76,1mm 6.50 x 3.00 4.00 5.7 (150 x 65) (165,1 x 76,1) (101,6) (2,6) E to E 165,1mm x 3 6.50 x 3.50 4.00 5.8 (150 x 50) (165,1 x 88,9) (101,6) (2,6) 165,1mm x 4 6.50 x 4.50 4.00 5.8 (150 x 50) (165,1 x 114,3) (101,6) (2,6) 165,1mm x 5 6.50 x 5.563 4.00 5.8 (150 x 50) (165,1 x 141,3) (101,6) (2,6) 6 x 1 6.63 x 1.31 4.00 5.2 (150 x 25) (168,3 x 33,4) (101,6) (2,4) 6 x 2 6.63 x 2.37 4.00 5.4 (150 x 50) (168,3 x 60,3) (101,6) (2,4) 6 x 2-1/2 6.63 x 2.87 4.00 5.6 (150 x 65) (168,3 x 73,0) (101,6) (2,5) 6 x 76,1mm 6.63 x 3.00 4.00 5.8 (150 x 65) (168,3 x 76,1) (101,6) (2,6) 6 x 3 6.63 x 3.50 4.00 6.0 (150 x 80) (168,3 x 88,9) (101,6) (2,7) 6 x 4 6.63 x 4.50 4.00 6.2 (150 x 100) (168,3 x 114,3) (101,6) (2,8) 6 x 5 6.63 x 5.56 4.00 6.7 (150 x 125) (168,3 x 141,3) (101,6) (3,0) NOTES a. Figure 372 not available for the EMEA market. FIGURE 11 (2 OF 2) FIGURE 372 FABRICATED CONCENTRIC REDUCER GROOVE X MALE THREAD (MPT) NOMINAL DIMENSIONS TFP1815 Page 19 of 26 Nominal Pipe Size Figures 211, 311, & 511 Figures 212, 312, & 512 Nominal Approx. Nominal Approx. O.D. ANSI Inches C to E Weight C to E Weight Inches (DN) Inches Lbs. Inches Lbs. (mm) (mm) (kg) (mm) (kg) 1-1/4 1.660 1.38 0.4 1.75 0.4 (32) (42,4) (35,1) (0,2) (44,5) (0,2) 1-1/2 1.900 1.38 0.5 1.75 0.5 (40) (48,3) (35,1) (0,2) (44,5) (0,2) C to E 2 2.375 1.38 0.6 1.88 0.6 (50) (60,3) (35,1) (0,3) (47,8) (0,3) 2-1/2a 2.875 1.50 1.1 2.00 0.7 (65)b (73,0) (38,1) (0,5) (50,8) (0.3) FIGURES 211, 311, & 511 76,1mm 3.000 1.50 1.1 2.00 1.2 FABRICATED 11¼° ELBOW (65) (76,1) (38,1) (0,5) (50,8) (0,5) (SEGMENT WELDED) 3 3.500 1.50 1.2 2.25 1.4 (80) (88,9) (38,1) (0,5) (57,2) (0,6) C to E 4 4.500 1.75 2.2 2.63 2.4 (100) (114,3) (44,5) (1,0) (66,8) (1,1) 139,7mm 5.500 2.00 2.3 2.88 2.5 (125) (139,7) (50,8) (1,0) (73,2) (1,1) 5 5.563 2.00 3.3 2.88 4.1 (125) (141,3) (50,8) (1,5) (73,2) (1,9) FIGURES 212, 312, & 512 FABRICATED 22½° ELBOW 165,1mm 6.500 2.00 3.5 3.13 4.3 (SEGMENT WELDED) (150) (165,1) (50.8) (1,6) (79,5) (2,0) 6 6.625 2.00 4.6 3.13 5.6 (150) (168,3) (50.8) (2,1) (79,5) (2,5) 8 8.625 2.00 8.7 3.88 11.1 (200) (219,1) (50,8) (3,9) (98,6) (5,0) 10 10.750 2.13 9.1 4.38 14.0 (250) (273,0) (54,1) (4,1) (111,3) (6,4) 12 12.750 2.25 16.7 4.88 22.0 (300) (323,9) (57,2) (7,6) (124,0) (10,0) NOTES a. Nominal Pipe Size 2-1/2 in. no longer Figure 311. b. Nominal Pipe Size 2-1/2 in. no longer Figure 312. FIGURE 12 FIGURES 211, 311, AND 511 FABRICATED ELBOWS AND FIGURES 212, 312, AND 512 FABRICATED ELBOWS NOMINAL DIMENSIONS TFP1815 Page 20 of 26 Nominal Pipe Size Figures 391, 392 & 393a Nominal Approx. E to E ANSI Inches O.D. Inches E to E Weight (DN) (mm) Inches Lbs. (mm) (kg) 1-1/4 1.660 4.00 0.8 (32) (42,4) (101,6) (0,4) 1-1/2 1.900 4.00 0.9 FIGURE 391a (40) (48,3) (101,6) (0,4) FABRICATED ADAPTER NIPPLE 2b 2.375 4.00 1.2 GROOVE X MALE THREAD (50) (60,3) (101,6) (0,5) (MA) 2-1/2b 2.875 4.00 1.9 (65) (73,0) (101,6) (0,9) E to E 76,1mm 3.000 4.00 1.9 (65) (76,1) (101,6) (0,9) 3 3.500 4.00 2.5 (80) (88,9) (101,6) (1,1) FIGURE 392a 4 4.500 6.00 5.5 FABRICATED (100) (114,3) (154,4) (2,5) ADAPTER NIPPLE GROOVE X GROOVE 139,7mm 5.500 6.00 5.6 (125) (139,7) (154,4) (2,5) E to E 5 5.563 6.00 7.4 (125) (141,3) (154,4) (3,4) 165,1mm 6.500 6.00 7.6 (150) (165,1) (154,4) (3,4) 6 6.625 6.00 9.5 FIGURE 393a (150) (168,3) (154,4) (4,3) FABRICATED 8 8.625 6.00 14.2 ADAPTER NIPPLE (200) (219,1) (154,4) (6,4) GROOVE X PLAIN 10 10.750 8.00 27.0 (250) (273,0) (203,2) (12,2) 12 12.750 8.00 33.0 (300) (323,9) (203,2) (15,0) NOTES a. Figure 391, Figure 392, and Figure 393 are not available for the EMEA market. b. Figure 391 2 in. x 4 in. (DN50 x DN100) and 2-1/2 in. x 4 in. (DN65 x DN100) are cast. FIGURE 13 FIGURES 391, 392, AND 393 FABRICATED ADAPTER NIPPLES NOMINAL DIMENSIONS TFP1815 Page 21 of 26 Nominal Nominal Approx. O.D. ANSI Inches C to GE C to TE Weight Inches (DN) Inches Inches Lbs. (mm) (mm) (mm) (kg C to TE 5 x 5 x 8 5.563 x 5.563 x 8.625 13.313 9.313 27.8 (125 X 125 X 200) (141,3 x 141,3 x 219,1) (388,14) (236,55) (12,6) 6 x 6 x 8 6.625 x 6.625 x 8.625 13.313 8.750 36.7 (150 X 150 X 200) (168,3 x 168,3 x 219,1) (388,14) (222,25) (16,4) C to GE NOTES a. Figure 507/50L not available for the EMEA market. FIGURE 14 FIGURE 507/50L FABRICATED BULLHEAD TEE NOMINAL DIMENSIONS Nominal Nominal Approx. ANSI Inches O.D. C to GE C to TE Weight C to TE Inches (DN) Inches Inches Lbs. (mm) (mm) (mm) (kg) 4 x 4 x 2-1/2 5.563 x 5.563 x 8.625 13.313 9.313 8.7 (100 X 100 X 65) (141,3 x 141,3 x 219,1) (388,14) (236,55) (3,9) 6 x 6 x 2-1/2 6.625 x 6.625 x 8.625 13.313 8.750 13.7 C to GE (150 X 50 X 65) (168,3 x 168,3 x 219,1) (388,14) (222,25) (6,2) NOTES a. Figure 328 not available for the EMEA and APAC market. FIGURE 15 FIGURE 328 FABRICATED STANDPIPE TEE NOMINAL DIMENSIONS TFP1815 Page 22 of 26 Friction Resistance Nominal Pipe Size Elbows Elbows Tee(1) Tee 90° 45° Branch Run O.D. Feet Feet Feet Feet ANSI Inches Inches (m) (m) (m) (m) (DN) (mm) 1 1.31 1.3 0.8 3.7 1.3 (25) (33,4) (0,4) (0.3) (1,1) (0.6) 1-1/4 1.7 1.9 1.0 4.8 1.9 (32) (42,4) (0,6) (0,3) (1,5) (0,6) 1-1/2 1.9 2.3 1.2 5.8 2.3 (40) (48,3) (0,7) (0,4) (1,8) (0,7) 2 2.4 3.2 1.6 8.0 3.2 (50) (60,3) (1,0) (0,5) (2,5) (1,0) 2-1/2 2.9 3.9 2.0 9.8 3.9 (65) (73,0) (1,2) (0,6) (3,0) (1,2) – 3.0 4.1 2.1 10.3 4.1 (65) (76,1) (1,2) (0,6) (3,1) (1,2) 3 3.5 4.9 2.4 12.2 4.9 (80) (88,9) (1,5) (0,7) (3,7) (1,5) 4 4.5 6.5 3.3 16.3 6.5 (100) (114,3) (2,0) (1,0) (5,0) (2,0) – 5.5 8.0 4.1 20.0 8.0 (125) (139,7) (2,4) (1,3) (6,1) (2,4) 5 5.6 8.2 4.1 20.5 8.2 (125) (141,3) (2,5) (1,3) (6,3) (2,5) – 6.5 9.5 4.8 23.8 9.5 (150) (165,1) (2,9) (1,4) (7,2) (2,9) 6 6.6 9.9 5.0 24.8 9.9 (150) (168,3) (3,0) (1,5) (7,6) (3,0) 8 8.6 13.1 6.6 32.8 13.1 (200) (219,1) (4,0) (2,0) (10,0) (4,0) 10 10.8 16.5 8.3 41.3 16.5 (250) (273,0) (5,0) (2,5) (12,6) (5,0) 12 12.8 19.9 9.9 49.7 19.9 (300) (323,9) (6,1) (3,0) (15,1) (6,1) NOTES a. For the reducing tee branches, use the value that is corresponding to the branch size. Example: For 8 in. x 8 in. x 2 in. tee, the branch value of 2 in. is 8.0 feet. For sizes not listed interpolate from the values shown. TABLE A FRICTION RESISTANCE FOR FIGURES 501, 510, 510DE AND 519 (EXPRESSED AS EQUIVALENT STRAIGHT PIPE) TFP1815 Page 23 of 26 Friction Resistance Nominal Pipe Size Elbows Elbows Tee* Tee 90° 45° Branch Run O.D. Feet Feet Feet Feet ANSI Inches Inches (m) (m) (m) (m) (DN) (mm) 2 2.4 3.5 1.6 8.0 3.2 (50) (60,3) (1,1) (0,5) (2,4) (1,0) 2-1/2 2.9 4.3 2.0 9.8 3.9 (65) (73,0) (1,3) (0,6) (3,0) (1,2) – 3.0 4.3 2.1 10.3 4.1 (65) (76,1) (1,3) (0,6) (3,1) (1,2) 3 3.5 5.0 2.4 12.2 4.9 (80) (88,9) (1,5) (0,7) (3,7) (1,5) 4 4.5 6.7 3.3 16.3 6.5 (100) (114,3) (2,0) (1,0) (5,0) (2,0) – 5.5 8.3 4.1 20.0 8.0 (125) (139,7) (2,5) (1,2) (6,1) (2,4) 5 5.6 8.5 4.3 21.5 8.6 (125) (141,3) (2,5) (1,3) (6,5) (2,6) – 6.5 9.6 4.8 23.8 9.5 (150) (165,1) (2,9) (1,5) (7,3) (2,9) 6 6.6 10.0 5.0 24.8 9.9 (150) (168,3) (3,0) (1,5) (7,6) (3,0) 8 8.6 13.1 6.6 32.8 13.0 (200) (219,1) (4,0) (2,0) (10,0) (4,0) TABLE B FRICTION RESISTANCE FOR FIGURES 510S AND 519S (EXPRESSED AS EQUIVALENT LENGTH OF STRAIGHT SCHEDULE 40 STEEL PIPE) TFP1815 Page 24 of 26 Figure 501 Figure 510 Figure 519 Nominal Pipe Cast 45° Elbow Cast 90° Elbow Cast Tee Size psi psi psi bar bar bar Ansi O.D. Inches Inches UL FM VdS LPCB UL FM VdS LPCB UL FM VdS LPCB (DN) mm 1 1.31 — — — — — — — — — — — — (25) (33,4) 1-1/4 1.66 365 365 232 290 365 232 290 — — — — — (32) (42,4) (25,2) (25,2) (16,0) (20,0) (25,2) (16,0) (20,0) 1-1/2 1.90 365 365 232 290 365 232 290 — — — — — (40) (48,3) (25,2) (25,2) (16,0) (20,0) (25,2) (16,0) (20,0) 2 2.37 365 365 232 290 365 365 232 290 365 365 232 290 (50) (60,3) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) 2-1/2 2.87 365 365 365 365 365 365 — — — — — — (65) (73,0) (25,2) (25,2) (25,2) (25,2) (25,2) (25,2) 76,1mm 3.00 365 365 232 290 365 365 232 290 365 365 232 290 (65) (76,1) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) 3 3.50 365 365 232 290 365 365 232 290 365 365 232 290 (80) (88,9) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) 4 4.50 365 365 232 290 365 365 232 290 365 365 232 290 (100) (114,3) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) 139,7mm 5.50 365 365 232 365 365 232 365 365 232 — — — (125) (139,7) (25,2) (25,2) (16,0) (25,2) (25,2) (16,0) (25,2) (25,2) (16,0) 5 5.56 365 365 365 — — — — — — — — — (125) (141,3) (25,2) (25,2) (25,2) 165,1mm 6.50 365 365 290 365 365 290 365 365 290 — — — (150) (165,1) (25,2) (25,2) (20,0) (25,2) (25,2) (20,0) (25,2) (25,2) (20,0) 6 6.63 365 365 232 290 365 365 232 290 365 365 232 290 (150) (168,3) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) 8 8.63 365 365 232 290 365 365 232 290 365 365 232 290 (200) (219,1) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) 10 10.75 450 232 290 450 232 290 450 232 290 — — — (250)a (273,0) (31,0) (16,0) (20,0) (31,0) (16,0) (20,0) (31,0) (16,0) (20,0) 12 12.75 450 232 290 450 232 290 450 232 290 — — — (300)a (323,9) (31,0) (16,0) (20,0) (31,0) (16,0) (20,0) (31,0) (16,0) (20,0) NOTES a. Marked as Grinnell. TABLE C FIGURE 501 AND FIGURE 510 CAST ELBOWS, AND 519 CAST TEE LISTED/APPROVED PRESSURE RATING TFP1815 Page 25 of 26 Figure 260 Figure 510S Figure 519S Nominal Pipe Cast End Cap Cast 90° Elbow Cast Tee Size psi psi psi bar bar bar Ansi O.D. Inches Inches UL FM VdS LPCB UL FM VdS LPCB UL FM VdS LPCB (DN) (mm) 1 1.31 500 — — — — — — — — — — — (25) (33,4) (34,5) 1-1/4 1.66 500 500 — — — — — — — — — — (32) (42,4) (34,5) (34,5) 1-1/2 1.90 500 500 — — — — — — — — — — (40) (48,3) (34,5) (34,5) 2 2.37 500 500 365 365 232 290 365 365 232 290 — — (50) (60,3) (34,5) (34,5) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) 2-1/2 2.87 500 500 365 365 365 365 — — — — — — (65) (73,0) (34,5) (34,5) (25,2) (25,2) (25,2) (25,2) 76,1mm 3.00 500 500 365 365 232 290 365 365 290 — — — (65) (76,1) (34,5) (34,5) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (20,0) 3 3.50 500 500 365 365 232 290 365 365 232 290 — — (80) (88,9) (34,5) (34,5) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) 4 4.50 500 500 365 365 232 290 365 365 232 290 — — (100) (114,3) (34,5) (34,5) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) 139,7mm 5.50 500 500 365 365 232 365 365 232 — — — — (125) (139,7) (34,5) (34,5) (25,2) (25,2) (16,0) (25,2) (25,2) (16,0) 5 5.56 500 500 365 365 — — — — — — — — (125) (141,3) (34,5) (34,5) (25,2) (25,2) 165,1mm 6.50 500 500 365 365 365 365 — — — — — — (150) (165,1) (34,5) (34,5) (25,2) (25,2) (25,2) (25,2) 6 6.63 500 500 365 365 232 290 365 365 232 290 — — (150) (168,3) (34,5) (34,5) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) 8 8.63 500 500 365 365 232 290 365 365 232 290 — — (200) (219,1) (34,5) (34,5) (25,2) (25,2) (16,0) (20,0) (25,2) (25,2) (16,0) (20,0) 10 10.75 500 500 — — — — — — — — — — (250) (273,0) (34,5) (34,5) 12 12.75 500 500 — — — — — — — — — — (300) (323,9) (34,5) (34,5) TABLE D FIGURE 260 CAST END CAP, FIGURE 510S CAST ELBOW, AND FIGURE 519S CAST TEE LISTED/APPROVED PRESSURE RATING TFP1815 Page 26 of 26 ADACAP Care and Nominal Pipe psi Size bar Maintenance The following inspection procedure Inches x NPT UL FM VdS LPCB must be performed as indicated, in (DN) addition to any specific requirements of the NFPA. Any impairments must be 1-1/2 x 1/2 300 300 — — immediately corrected. (40) (20,7) (20,7) Before closing a fire protection system 1-1/2 x 3/4 300 300 (40) (20,7) (20,7) — — main control valve for maintenance work on the fire protection system 1-1/2 x 1 300 300 — — that it controls, obtain permission to (40) (20,7) (20,7) shut down the affected fire protection 2 x 1/2 300 300 system from the proper authorities — — (50) (20,7) (20,7) and notify all personnel who may be 2 x 3/4 300 300 affected by this decision. — — (50) (20,7) (20,7) The owner is responsible for the 2 x 1 300 300 inspection, testing, and maintenance of — — (50) (20,7) (20,7) their fire protection system and devices in compliance with this document, as 2-1/2 x 1/2 300 300 (65) (20,7) (20,7) — — well as with the applicable standards of the NATIONAL FIRE PROTECTION 2-1/2 x 3/4 300 300 — — ASSOCIATION, for example, NFPA (65) (20,7) (20,7) 25, in addition to the standards of any 2-1/2 x 1 300 300 authority having jurisdiction. Contact — — (65) (20,7) (20,7) the installing contractor or product manufacturer with any questions. TABLE E ADACAP Automatic sprinkler systems are rec- LISTED/APPROVED PRESSURE RATING ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure GRINNELL Products are available glob- ally through a network of distribution centers. For the nearest distributor, visit www.grinnell.com. When placing an order, indicate the full product name. Specify the quantity, figure number, wall thickness, and size. 1467 Elmwood Avenue, Cranston, RI 02910 | Telephone +1-401-781-8220 © 2022 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Worldwide www.tyco-fire.com Contacts TFP1815 Change History Appendix ISSUE DATE NOTES Page 1, added QR code and URL to allow convenient access to electronic version from printed docu- ment; Page 26, changed corporate address and telephone number to 1467 Elmwood Avenue, Crans- 08-22 ton, RI 02910 | Telephone +1-401-781-8220, formerly 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700. Updated NOTICE in General Description to add statement advising customers internal protective coat- 10-21 ings can become separated from fittings during system operation, potentially causing blockage in systems equipped with strainers or filters featuring mesh sizes less than 5/32 in. (4 mm). Updated Figure 391 Adapter Nipple Groove x Male Thread sizes 2 in. (DN50) and 2-1/2 in. (DN65) to 04-21 indicate they cast; formerly shown as fabricated. Moved dimension and weight data of 2 in. x 1-1/4 in. (DN50 x DN32) and 2 in. x 1-1/2 in. (DN50 x DN40) sizes to Figure 550 Concentric Reducer; formerly Figure 350 (not offered); Added 2 in. (DN50), 2-1/2 in. 02-21 (DN65) and 4 in. (DN100) size to Figure 227 Cross; Removed 2-1/2 in. (DN65) size from Figure 311 11-1/4° and Figure 312 22-1/2° Elbows; Added agency Listed and Approved pressure ratings for 10 in. (DN250) and 12 in. (DN300) sizes to Figure 501 45° and Figure 510 90° Elbows and Figure 519 Tee. Standardized nominal pipe size values for metric fittings and mixed imperial and metric reducing fittings, 12-20 including 76,1mm, 108,0mm, 139,7mm, 165,1mm and 216,3mm. Added carbon steel specifications to Technical Data Material sub-section for fabricated fittings; Updated 08-19 document title to reflect iron and steel materials. Added new sizes: Figure 250 Cast Concentric Reducer; Figure 510 Cast 90 Elbow; Figure 519 Cast Tee; 03-19 Figure 260 Cast End Cap. Updated Grinnell® branding and document format; Added Johnson Controls copyright; Added dis- 08-18 claimer stating specifications and information subject to change without notice; Added reference to Regulatory and Health Warning Technical Data Sheet TFP2300. Corrected C to E dimension for 8 in. (DN200) Figure 501 45º Elbow to 4.25 in. (108,0 mm), formerly 4.5 05-17 in. (108,0 mm). Updated fitting weights; Expanded variety of fittings and available sizes; Clarified regional availability 01-16 of protective coatings. 07-12 New Technical Data Sheet TFP1815 describes Grinnell G-FIRE Grooved Fittings. 1467 Elmwood Avenue, Cranston, RI 02910 | Telephone +1-401-781-8220 © 2022 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. ™ www.tolco.com a brand of ® Revision 8/01/2003 Fig. 1001 - Sway Brace Attachment Size Range — Pipe size to be braced: 21/ Component of State of 2" thru 8" IPS.* Pipe size used California OSHPD Approved 1/ for bracing: 1" and 1 4" Schedule 40 IPS. Seismic Restraints System Material — Carbon Steel Function — For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: The Fig. 1001 is used in conjunction with a TOLCO™ 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features — *Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnec- essary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note — Position Fig. 1001 over the pipe to be braced Maximum Design Load and tighten two hex head cone point set bolts until heads bottom Sch 7 - 1600 lbs. out. A minimum of 1" pipe extension is recommended. Sch 10 & 40 w/1" Brace Pipe - 2015 lbs. Approvals — Underwriters Laboratories Listed in the USA (UL) and 1/ Sch 10 & 40 w/1 4" Brace Pipe - 2765 lbs. Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note — Available in Electro-Galvanized and HDG finish. Order By — Indicate pipe size to be braced followed by pipe size used for bracing, figure number and finish. Important Note — The Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that the Fig. 1001 must be used only with other TOLCO bracing products. The Fig 1001 is not intended for use with the Fig. 907 4-Way Longitudinal Brace Attachment. NATIONAL AND INTERNATIONAL PATENT APPLICATION IN PROCESS Office/Manufacturing Facility •1375 Sampson Ave. •Corona, CA 92879 •Ph: 909.737.5599 •Fax: 909.737.0330 Customer Service •800.786.5266 169 www.tolco.com ™ www.tolco.com a brand of ® Revision 5/24/2001 Fig. 4L Longitudinal “In-Line” Sway Brace Attachment Size Range — 2 ½" through 8" IPS. Material — Carbon Steel Function — For bracing pipe against sway and seismic disturbance. Approvals — Underwriter's Laboratories Listed in the USA (UL) and Canada (cUL) 2 ½" through 8". Installation Instructions — Install Fig. 4L on the pipe to be braced. Tighten bolts on ears of clamp securely. Insert brace pipe in swivel jaw and tighten set screw until head breaks off. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. Finish — Plain Note — Available in electro-galvanized and HDG finish. Order By — Figure number, pipe size and finish. Important Note — The Fig. 4L is precision manufactured to perform its func- tion as a critical component of a complete bracing assembly. To ensure per- formance, the UL Listing requires that the Fig. 4L must be used only with other TOLCO bracing products. Dimensions • Weights Bolt Max. Rec. Approx. Sizes A CD Size Load Lbs. Wt./100 21/ 7 1 3 2 6/16 2/2 2/4 1/2 2015 253 3/ 1 37 2 4 3/16 1/2 2015 268 1/ 3 11 48 2 3/8 3 /16 1/2 2015 348 593/ 7 3 4 3/8 4/8 1/2 2015 380 1/ 1 611 2 55/8 1/2 2015 640 1/ 11 1 813 4 6 /16 6/8 1/2 2015 728 Longitudinal Brace 4-Way Riser Brace Transverse Brace (Plan view) Office/Manufacturing Facility •1375 Sampson Ave. •Corona, CA 92879 •Ph: 909.737.5599 •Fax: 909.737.0330 30 Customer Service •800.786.5266 www.tolco.com ™ www.tolco.com a brand of ® Revision 5/24/2001 Fig. 200 - “Trimline” Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. 1/ •(2 2" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCO™ Fig. 200WON. Order By — Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. AB Size Inch Metric Load Lbs. Length 1/2 3/8 8mm or 10mm 31/ 5 8 2/8 400 11 1/ 1 3/4 3/8 8mm or 10mm 3 8 2/2 400 11 3/ 5 1 3/8 8mm or 10mm 3 8 2/8 400 12 11/ 3 7 4 3/8 8mm or 10mm 3/4 2/8 400 13 1/ 7 7 1 2 3/8 8mm or 10mm 3/8 2/8 400 14 1/ 2 3/8 8mm or 10mm 4 2 3 400 15 21/ 5 1 2 3/8 10mm 5/8 4/8 600 27 7/ 3 3/8 10mm 5 8 4 600 29 1/ 3 1 3 2 3/8 10mm 7/8 5/4 600 34 4 3/8 10mm 73/ 8 5 1000 35 1/ 1 5 1/2 12mm 9 8 6/4 1250 66 1/ 3 6 1/2 12mm 10 8 6/4 1250 73 1/ 3 8 1/2 12mm 13 8 8/4 1250 136 Main Office/Manufacturing Facility •1375 Sampson Ave. •Corona, CA 92879 •Ph: 909.737.5599 •Fax: 909.737.0330 86 Customer Service •800.786.5266 www.tolco.com ™ www.tolco.com a brand of ® Revision 5/24/2001 Fig. 98 - Rod Stiffener Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number Fig. 99 - All Thread Rod Cut to Length Size Range — Secures 3/8" thru 7/8" rod in Dimensions • Weights 1" increments Rod Max. Rec. Load Lbs. Material — Carbon Steel Size For Service Temps 650°F 750°F Maximum Temperature — 750°F 3/8 610 540 Finish — Plain 1/2 1130 1010 Note — Available in Electro-Galvanized and 5/8 1810 1610 HDG finish or Stainless Steel materials. 3/4 2710 2420 7/8 3770 3360 Order By — Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range — Secures 3/8" thru 7/8" rod in 10’ lengths Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 1/ 1 4 8000 7140 360 1/ 1 2 11630 10370 510 Main Office/Manufacturing Facility •1375 Sampson Ave. •Corona, CA 92879 •Ph: 909.737.5599 •Fax: 909.737.0330 68 Customer Service •800.786.5266 www.tolco.com www.tolco.com Revision 12/3/2008 Fig. 78 - All Steel Ceiling Plate Size Range — 3/8" rod Material — Carbon Steel Features — Attachment to wood beams, ceilings, metal decks or walls. Can also be welded to steel beams. Approvals — Underwriters’ Laboratories Listed in the USA (UL) C A and Canada (cUL). Additionally, (UL) has listed the Fig. 78 with fasteners as shown in the table below. B Finish — Plain Note — Available in Electro-Galvanized and HDG finish. Order By — Figure number, rod size and finish E Patent #5,702,077 D(2) UL Listed Fastener Table Pipe Size Qty Fastener Type Material 1/2 - 2 2 #14 x 11⁄4 A-point hex-washer-head sheet metal screw Wood 21⁄2 - 4 2 1/4 x 11⁄2 wood screws* Wood 1/2 - 2 2 1/4 x 1 tek screws Metal (18 gauge) 1/2 - 2 2 #14 x 11⁄4 A-point hex-washer-head sheet metal screw Wood 1/2 - 2 2 #14 x 2 A-point-hex-washer-head sheet metal screw Wood thru 5/8" gyp board * No pre-drilling Dimensions • Weights Max. Rec. Approx. A B C D E Pipe Size Load Lbs.* Wt./100 1/2 - 2 3 21⁄8 11⁄8 5/16 3/8 150 15 5 - 6 Consult factory for data * Minimum safety factor of 5 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 68 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Permit #: 6649 Permit Date: 07/28/25 Permit Type: FIRE SPRINKLER Project Name: President's Elementary FS Applicant Name: Southeast Fire Protection Applicant Address: 113 Harvest Way #12 Applicant, City, State, Zip: Sitka, AK, 99835 Contact: Mark Stevens Phone: 2069728125 Email: mtstevens62@yahoo.com Scope of Work: new freezer and cooler fire sprinkler modification Valuation: 35000.00 Square Feet: 62689 Number of Stories: 2 Construction Type: VB Occupancy Group: E; Education ID Code: Permit Issued: 09/08/2025 Permit Expires: 03/06/2026 Form Permit Type: FIRE SPRINKLER Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel # Address Legal Description Owner Name Owner Phone Zoning ARLINGTON 31050200401500 505 E 3RD STREET SCHOOL DISTRICT 690 EDUCATION 16 Contractors Contractor Primary Contact Phone Address Contractor Type License License # Southeast Fire CONSTRUCTION Mark Stevens 206-972-8125 113 Harvest Way UBI 603 316 812 Protection CONTRACTOR Southeast Fire CONSTRUCTION Mark Stevens 206-972-8125 113 Harvest Way L&I SOUTHFP879NR Protection CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status FS07. FIRE 09/10/2025 final ok 09/11/2025 09/26/2025 FIRE Approved SPRINKLER FINAL Plan Reviews Date Review Type Description Assigned To Review Status 08/13/2025 FIRE SPRINKLER BUILDING Approved 08/13/2025 FIRE SPRINKLER Fire Sprinkler TI Plan Review FIRE Approved Fees Fee Description Notes Amount Fire System Plan Review Table 4-2 $480.12 Credit Card Service $14.40 Processing/Technology $25.00 Fire Sprinkler System Commercial NFPA 13/13R $225.00 Credit Card Service $7.50 Total $752.02 Attached Letters Date Letter Description 09/08/2025 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 08/13/2025 James Mattingly 239973813 Hannah Hardwick $14.40 XBP Conf: 08/13/2025 $480.12 239973813 09/08/2025 James mattingly 242369346 Hannah Hardwick $7.50 XBP Conf: 09/08/2025 $250.00 242369346 Outstanding Balance $0.00 Notes Date Note Created By: 07/28/2025 Contractor needs to add COA to UBI Hannah Hardwick Uploaded Files Date File Name 09/08/2025 28164053-2025_BLD6649_Issued Permit.pdf 09/08/2025 28161446-20250728_BLD6649_Approved Plans.pdf 07/28/2025 27541472-20250728_BLD6649_App.pdf 07/28/2025 27541473-20250728_BLD6649_Plans.pdf 07/28/2025 27541474-20250728_BLD6649_Material Submittals.pdf ABBREVATIONS SYMBOL LEGEND HEAD LEGEND GENERAL NOTES QTY. ADJ Adjustable 1. The system design and installation shall comply with NFPA 13 2019 and the FIN. AFF Above Finished Floor SYMBOL DESCRIPTION SIN # NPT K FACTOR TEMP FINISH/ESCUTCHEON PROJECT COMMENTS Authority Having Jurisdiction. Upright Sprinkler TOTALS AHJ Authority Having Jurisdiction ANSI American National Standards Institute Pipe Diameter (inches) TYCO TY-FRB UPRIGHT TY313 1/2" 5.6 200° BRASS 12 2. Hazard classification: ORIF. AS Automatic Sprinklers JOB TOTAL New Sprinkler Branchline - Steel Ordinary Hazard I ASME American Society of Mechanical Engineers Pipe Length (feet-inches) .15 gpm per sq. ft. over most remote *1,950 sq. ft. T° F ASR Automatic Sprinkler Riser (U.O.N.) *area of operation increased 30% for dry system ASTM American Society for Testing and Materials Existing Sprinkler Pipe - Steel Actual remote area entire freezer/cooler - 1,112 sq. ft. ATR All Thread Rod SIZE Min. sprinkler system flow (.15 X 1950) = 292.5 gpm AUX Auxiliary Per NFPA 13: 2019 paragraph 27.2.4.2.4 additional flow is added at hydraulic AV Alarm Valve Change in Pipe Elevation reference node 17 (81.5 gpm). AWS American Welding Society TOTALS 12 COMMENTS BB Below Beam 3. Provide spare sprinklers & wrenches within head cabinet as required. BD Below Deck BFP Backflow Preventor System Riser (Wet) BFV Butterfly Valve Existing 4. All piping to be as follows: BJ Below Joist All threaded piping to be schedule 40 black steel or equal. BL Branchline System Riser (Dry) All grooved pipe to be schedule 10 black steel or equal. BLDG Building Existing BOR Base Of Riser UPRIGHT SPRINKLER DETAIL 5. Fittings shall be class 125 threaded cast iron ANSI B16.4. BR Brass Hydraulic Reference Point CH Chrome 6. All threaded pipe and fittings shall have threads cut to ANSI/ASME standard CI Cast Iron SCALE: NTS B1.20.1. CL Centerline Grooved Coupling COJ Cut On Job 7. All pipe welding shall be in compliance with the requirements of AWS B2.1 DESCRIPTION COL Column (standard for building service piping). CONC Concrete Auxiliary Drain (NOTE: ALL SPRINKLERS SUBJECT TO MECHANICAL DAMAGE TO HAVE HEAD GUARDS) COUP Coupling 8. All piping shall be earthquake braced as outlined in NFPA 13 2019. CPVC Chlorinated Polyvinyl Chloride CSP Combination Standpipe Grooved Cap 9. Electrical wiring and any painting of the pipe that may be required shall be by CSR Coach Screw Rod others. CTR Center CV Check Valve Threaded Cap 10. All piping is to be hydrostatically tested at 200 psi minimum, for a period not less DCV Detector Check Valve than two hours. DI Ductile Iron DN Down Plug 11. Water Flow Information: Static 64.6 psi Residual 51 psi with 2724 gpm flowing. DSP Dry Standpipe E Existing 12. Provide clearance around all pipe passing through walls, floors, platforms, and EC Extended Coverage Hanger Location foundations in accordance with NFPA 13:2019 paragraph 9.3.4. ELEV Elevation ELL Elbow Fitting 13. Scope of Work: Existing freezer/cooler to be replaced with new freezer/cooler. EQB Earthquake Brace EXP Exposed Hanger Location Demo existing sprinkler system and replace with new system. F Flanged HANGER DETAIL FDC Fire Department Connection P.O. BOX 624 FH Fire Hydrant Sway Bracing ALASKA:(907) 747-3135 LIC. # SOUTHFP879NR FHC Fire Hose Cabinet FHV Fire Hose Valve SITKA, ALASKA 99835 WASHINGTON : (206) 972-8125 MAXIMUM DISTANCE BETWEEN HANGERS HANGER ROD SIZES FLR Floor Lateral Sway Bracing FM Factory Mutual Research (short rod substitution) NOMINAL PIPE NOMINAL PIPE (907) 747-3135 LIC. # A-19275 FOW Face Of Wall 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4" SIZE (in.) SIZE (in.) SOUTHEAST FIRE PROTECTION FP Fire Protection Not In Scope FS Flow Switch STEEL PIPE EXCEPT N/A 12-0 12-0 15-0 15-0 15-0 15-0 15-0 STEEL PIPE EXCEPT N/A 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" FT Foot THREADED LIGHTWALL THREADED LIGHTWALL FTO Field To Order THREADED LIGHTWALL THREADED LIGHTWALL N/A 12-0 12-0 12-0 12-0 12-0 12-0 12-0 N/A 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" G Grooved STEEL PIPE STEEL PIPE GA Gauge GALV Galvanized GB Glass Bulb GOE Groove One End GOL Groove-O-Let GPM Gallons Per Minute GRC Grooved Reducing Coupling GV Gate Valve HDI Hilti Drop-in Anchor HSW Horizontal Sidewall HT Height HV Hose Valve ID Inside Diameter MECH Mechanical MJ Mechanical Joint MRA Most Remote Area MT Mechanical Tee NFPA National Fire Protection Association NIC Not In Contract NO Number NPT National Pipe Thread NTS Not To Scale OC On Center OD Outside Diameter OH Ordinary Hazard OS&Y Outside Screw & Yoke P Plain End PIV Post Indicator Valve PL Property Line POC Point Of Connection PRV Pressure Regulating Valve PS Pressure Switch SWAY BRACE DETAILS PSI Pounds Per Square Inch PVC Polyvinyl Chloride QR Quick Response RES Residential RN Riser Nipple SBB Side Beam Bracket ARLINGTON, WA SCH Schedule 505 E 3RD STREET SHT Sheet SP Standpipe SPK Sprinkler SQ Square SR Standard Response SSP Standard Spray Pendent SSU Standard Spray Upright SW Switch T Thread TEE Tee Fitting LW Threaded Lightwall STRUCTURAL ATTACHMENT - STEEL BEAM - DETAIL "A" PIPE ATTACHMENT - LATERAL TOE Thread One End TOR Top Of Riser TW Thinwall PRESIDENTS ELEMENTARY SCHOOL TYP Typical REVISIONS STRUCTURAL ATTACHMENT - STEEL BEAM - DETAIL "B" PIPE ATTACHMENT - LONGITUDINAL VICINTY MAP SHEET TITLE SCALE: NTS TITLE SHEET WASHINGTON STATE CERTIFICATE OF COMPETENCY DATE: JULY 25, 2025 FIRE PROTECTION SPRINKLER SYSTEMS FILE: 35638 Eric A Price 7/25/25 3437-0508-C Level 3 Date Southeast Fire Protection SOUTHFP879NR Expires Eric Price 12/31/25 FP1 Signature 1 OF 2 QTY. FIN. ORIF. JOB TOTAL T° F (U.O.N.) SIZE WATER FLOW INFORMATION DESCRIPTION (NOTE: ALL SPRINKLERS SUBJECT TO MECHANICAL DAMAGE TO HAVE HEAD GUARDS) P.O. BOX 624 SECTION "A" ALASKA:(907) 747-3135 LIC. # SOUTHFP879NR SITKA, ALASKA 99835 WASHINGTON : (206) 972-8125 (907) 747-3135 LIC. # A-19275 SOUTHEAST FIRE PROTECTION COOLER FREEZER SCALE: 1/4" = 1'-0" T ARLINGTON, WA 505 E 3RD STREET PROJECT LOCATION PRESIDENTS ELEMENTARY SCHOOL REVISIONS KEY PLAN SCALE: NTS OVERHEAD PIPING PLAN SHEET TITLE ALL PIPE TO BE PITCHED FOR DRAINAGE PER NFPA 13 SCALE: 1/4" = 1'-0" OVERHEAD PIPING PLAN WASHINGTON STATE CERTIFICATE OF COMPETENCY DATE: JULY 25, 2025 FIRE PROTECTION SPRINKLER SYSTEMS FILE: 35638 Eric A Price 7/25/25 3437-0508-C Level 3 Date Southeast Fire Protection SOUTHFP879NR Expires Eric Price 12/31/25 FP2 Signature 2 OF 2