Loading...
HomeMy WebLinkAbout19818 74th Ave_BLD6560_2025 CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 19818 74TH AVE Permit #: 6560 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 31051400202900 DATE OF ISSUANCE. Scope of Work: NOTE: SUBMITTAL IS DUE TO PREVIOUS ISSUED PERMIT Valuation: 500.00 BEING EXPIRED...INSTALLATION OF A NEW UL LISTED WIRELESS FIRE ALARM COMMUNICATOR. THE NEW COMMUNICATOR WILL BE TIED INTO THE EXISTING FACP. OWNER APPLICANT CONTRACTOR WINNERS COURT ENTERPRISES LLCNICK CHANDLER W/ FIRE FIRE PROTECTION INC PROTECTION INC 19818 74TH AVE NE 17410 ASH WAY, STE 8 1730 Gibson Rd ARLINGTON, WA 98223 LYNNWOOD, WA, 98037 Everett, WA 98204 425.290.9600 425-290-9600 LIC: 601 848 346 EXP: 01/31/2026 LIC: FIREPI*021ML EXP: 07/13/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC #: EXP: LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE ALARM CODE YEAR: 2021 STORIES: 2 CONST. TYPE: lA DWELLING UNITS: OCC GROUP: B; Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 06/25/2025 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved plans. Permit shall be onsite for inspections. Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 06/25/2025 Web Only - Fire System Plan Review $200.00 06/25/2025 Credit Card Service $6.00 06/25/2025 Processing/Technology $25.00 06/25/2025 FACP / Transmitter - Replace $125.00 06/25/2025 Fire Alarm System Permit $75.00 Total Due: $431.00 Total Payment: $431.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail FIRE ALARM PERMIT APPLICATION Community and Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 Type of Permit:  New Installation  System Modification  Phased Installation Property Address: Suite No.: Project Valuation: Lot #: Parcel ID No.: Preferred Contact:  Owner  Applicant Contractor Project Description: Owner Name: Phone No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Applicant Name: Phone No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Contractor Name: Phone No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation Submit electronic files of the follow:  Complete and Scaled Plans  Specification Sheets  Wiring Diagrams (Point to Point Wiring)  Electrical Plans, if applicable NOTE: All Central Station Monitoring must be UL or FM listed. FIRE ALARM SYSTEMS (105.7.3) ** DEVICES include separate individual portions of a Fire Alarm System such as: Initiating Devices, Notification Appliances, Flow Switch, Supervisory Switches, Magnetic Door Hold-Open Devices, Remote Annunciators, Pull Stations, Beam Detectors, and other such devices. (Each piece is one device) PLAN REVIEW FEES - shall be paid at time of application submittal Less than $5,000.00 = $200.00 $5,000.00 & over – based on project valuation (Plan Review Fee is 65% of project valuation per Fee Calculation Table 4-1) REV2022 Page 1 of 2 REINSPECTION / PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application – review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour (1 hour minimum) $75.00  TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 72) Number of Devices** Device Fee Subtotal 1 to 2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ > 200 $500.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices = $500.00 + $ = $ FACP/ TRANSMITTER Modification $125.00 = $ PERMIT FEE SUBTOTAL $  NEW COMMERCIAL SYSTEM (NFPA 72) Number of Devices** Device Fee Subtotal 1 to 100 $350.00 = $ 101 to 200 $475.00 = $ > 200 $500.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices = $500.00 + $ = $ FACP/ TRANSMITTER New $200.00 = $ PERMIT FEE SUBTOTAL $ PERMIT FEE TOTAL $ PLAN REVIEW FEE $ Processing/Technology Fee $25.00 TOTAL $ I hereby certify that I am the Owner, Applicant, Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. Signature Print Name Date REV2.2024 Page 2 of 2 FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM OPERATIONAL MATRIX TELGUARD INSTALLATION DETAIL SHEET INDEX SYSTEM OUTPUTS Required Fire Safety Control PROJECT DETAILS Central Supervising Station Control Unit Annunciation 1 TERMINAL FOR WIRING TO BE TELGUARD TROUBLE INSTALLED IN A MONITORING 120 VAC METAL RACEWAY 60 Hz, 1.5A AC POWER INPUT LOW VOLTAGE NO X-FORMER IN TERMINAL BLOCK 2 NEMA BOX MAIN BOARD COMRELAY 1 NC CONTACT INFO NO TELCO IN RELAY 2 COM OWNER / TENANT FIRE ALARM CONTRACTOR WIRING TO BE INSTALLED IN A NC METAL RACEWAY BATTERY TERMINAL BLOCK 1 Actuate Audible Alarm SignalActuate Audible Supervisory SignalActuate Audible Common Trouble SignalTransmit Fire Alarm Signal to Supervising StationTransmit Supervisory Signal to the Supervising StationTransmit Trouble Signal to the Supervising StationTransmit Waterflow Alarm to the Supervising Station Activate Building's Occupant Notification DevicesActivate Exterior Strobe for Approaching Emergency Vehicles SYSTEM INPUTS A B C D E F G H I CODE INFORMATION 1 Manual Fire Alarm Pull-Station 1 TELCO 1 PHONE 1 TELCO 2 PHONE 2 TROUBLE SLC IN SLC OUT SLC PROG SBUS ZONE 1 NAC 1* DRAWN BY: NICK CHANDLER, AET NICET III - #148121REVIEWED BY DAVID MOW, SET NICET IV - #120904SEATTLE FIRE DEPT. #SCP-C 9955L & I #CATS*RL022CGPROPERTY OF / ALL RIGHTS RESERVED F.P.I.DAVID MOW: TELGUARD TG-7FS COMMUNICATOR RING TIPRING TIPRING TIPRING TIPNO COM NC - + - + - + - + A B - + - + 2 Smoke Detectors 2 REVISION RECORD ALRM3 Wet Waterflow 3 DATE / DESCRIPTION 4 Unused 4 REV 06.16.2025- 5 Sprinkler Tampers / PIV 5 SUP6 Unused 6 RE-APPLY FOR PERMIT DUE 1 TO PREVIOUS ONE BEING 7 Fire Alarm AC Power Failure 7 EXPIRED BEFORE WORK TO BE COMPLETED, PLEASE 8 Fire Alarm System Low Battery 8 REFERENCE EMAIL FROM AHJ TRBL9 Open Circuit 9 IN WITH THE FA SUBMITTALS. 10 Ground Fault 10 A B C D E F G H I EXISTING FIRE ALARM PANEL ( SILENT KNIGHT SK-5208 ) INSTALLATION NOTES TYPICAL WIRING AND INSTALLATION DETAILS VICINITY MAP “ ” SITE PLAN DATE: 08/02/2024 PROJECT NAME 201ST ST NE 74TH AVE NE N Not to Scale DEVICE INSTALLATION REQUIREMENTS 19818 74TH AVE NE ARLINGTON, WA 98223 OUTDOOR HORN/STROBE BESTWORTH ROMMEL INC SHEET TITLE FACP BY SPRINKLER FIRE ALARM PROJECT DETAILS 197TH ST NE SHEET NUMBER FA 0.0 FIRE PROTECTION, INC. PO BOX 12642 MILL CREEK, WA 98082 (425) 290-9600 OR 1-800-681-1125 FAX (425) 353-4546 June 16, 2025 CITY OFARLINGTON – FIRE PREVENTION RE; FACP Wireless Communicator Installation 1. THE AHJ IS REQUIRING A NEW SUBMITTAL FOR THE PREVIOUS EXPIRED PERMIT, PERMIT NUMBER BLD-6102. REFERENCE AHJ EMAIL IN WTH THE FA SUBMITTALS. 2. THE EXISTING TWO-STORY BUILDING IS FULLY SPRINKLED AND HAS AN EXISTING CONVENTIONAL FIRE ALARM CONTROL PANEL ( SILENT KNIGHT SK-5208 FIRE PANEL ) LOCATED IN THE FIRE SPRINKLER ROOM. 3. A NEW UL LISTED WIRELESS CELL COMMUNICATOR (TELGUARD TG-7FS COMMUNICATOR) IS BEING INSTALLED AT THE FACP. ALL SIGNALS WILL BE TRANSMITTED BY ZONES TO THE UL LISTED SUPERVISING STATION. 4. THE NEW CELLULAR COMMUNICATOR SHALL TRANSMIT THE EXISTING FACP ZONES. 5. NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE. INSTALLATION COMPANY Fire Protection, Inc. 14710 ASH WAY, STE 8. LYNNWOOD, WA. 98204 WSCL# FIREPI*021ML UL CERT #608242-002 SITE ADDRESS BESTWORTH-ROMMEL, INC 19818 74TH AVE NE, ARLINGTON, WA 98223 APPROVED UL MONITORING COMPANY Secure Pacific 8220 North Interstate Ave, Portland, OR 97217 1.800.934.9304 CONTRACTUAL RESPONSIBLE PARTIES Installation; Monitoring Fire Protection, Inc. Should you have any further questions, please feel free to contact me directly. DAVID MOW, SET NICET-IV #120904 VP of OPERATIONS/Designer EXISTING FIRE ALARM CONTROL PANEL NEW WIRELESS COMMUNICATOR C OMMERCIAL FIRE Part of the full line of Telguard universal fire communicators, the TG-7FS can augment or replace legacy Telco lines with reliable cellular signal reporting. AHJs know that the TG-7FS meets all UL and ULC standards, and works in virtually every installation. PRODUCT FEATURES Powers directly from a 12 or 24VDC alarm panel — no electrician needed for an outlet. Or, for AC, use included plug-in adapter. Operates on LTE-M networks, for 5G longevity, lower power consumption, and better in-building penetration. Interfaces with fire panels using a single DACT connection for universal compatibility. No DACT is no problem — just add a TG-PEM accessory to the TG-7FS. American made, and backed by award-winning, U.S.-based tech support. This is the communicator dealers have loved for over a decade, updated with a more modern 5G LTE-M cellular radio, more efficient use of power, and more options. You’re in control when setting up and installing the TG-7FS. Apply desired settings when you’re in the office or on the road using the Telguard online dealer portal. Signals can be reported to your central station of choice. UL Listings (AT&T and Verizon) Size (without antenna) Specifications • 864 Commercial Fire 7.5 H x 11.5 W x 3.5 D in Power Consumption • 1610 Central Station (19.05 x 29.21 x 8.89 cm) Standby: 18mA @ 24VDC ULC Listings (AT&T Only) Package Contents 40mA @ 12VDC Transmit: 110mA @ 24VDC • S559 Commercial Fire • TG-7FS universal communicator 200mA @ 12VDC • S304 Commercial Burglary • Antenna with extension cable • AC adapter & connector blocks Compatible Formats Models by Carrier CID, SIA, Pulse (4x2, 3x1), • AT&T (US & Canada): TG-7FS-A Compatible Accessories Radionics (IIe/3a2,4), DMP • Verizon (US only): TG-7FS-V • TG-PEM to connect DACT-less panels • Range of antenna cable lengths • High-gain directional antenna • External antenna For the most current product specifications and UL Listings visit telguard.com/tg-7fs. In Canada, cellular data may be carried by Rogers, Bell, Telus or SaskTel. CHOOSE THE COMMUNICATOR THAT BEST FITS THE NEEDS OF YOUR UPGRADE, TAKEOVER, OR NEW INSTALL PROJECT. 800.229.2326 | 3225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 • USA | telguard.com ©2021 Telguard | Telguard and the Telguard Logo are registered trademarks of Telular Corporation. | Telular is a business unit of AMETEK, Inc. All Rights Reserved. 112021RevE BATTERY CALCULATIONS TG-7FS TG-7FS + TG-PEM Current Draw Current Draw Idle: 42mA Idle: 46mA Transmit: 110mA Transmit: 132mA Device Status Time Frame Consumption (AH) Consumption (AH) Idle with Link Supervision 24 Hours (1440 minutes) 1,008mAH 1,104mAH Alarm Transmitting Mode 5 Minutes 10mAH 11mAH Subtotal: 1,018mAH 1,115mAH Add 25% for battery depletion: 255mAH 279mAH Battery Calculation Estimate: 1,273mAH 1,394mAH David Mow From: Service Sent: Monday, June 2, 2025 7:31 AM To: David Mow Cc: Service; Emily Golden Subject: RE: BLD6102 Expired Permit Attachments: 8.29.24 - Fire Alarm Permit - JP (2).pdf Hello, I removed the contact, please see the info below. 713 - Bestworth Rommel Service Address: (TG7 Install) 19818 74th Ave NE Arlington, WA 98223 Logan Fultonberg Service Advisor Fire Protection, Inc. –Washington’s Most Trusted Name in Fire Safety Since 1968 17410 Ash Way, Suite 8 1 Lynnwood, WA 98037 logan@fpiseattle.com p:(425) 290-9600 f: (425) 787-9705 www.FPISEATTLE.com Fire Alarm • Sprinkler • Security • Access Control • CCTV • ERRC • Extinguisher • Kitchen Hoods Monitoring • Installation • Service • Inspections Optimize your support experience by contacting our specialized teams through these dedicated inboxes: Service@ Inspections@ Sales@ Billing@ From: David Mow <david@fpiseattle.com> Sent: Monday, June 2, 2025 7:01 AM To: Kristin Foster <kfoster@arlingtonwa.gov> Cc: Service <service@fpiseattle.com> Subject: RE: BLD6102 Expired Permit Hi Kristin, Can you please provide the address associated with this permit? Thank you Regards, David Mow, SET V.P. of Operations NICET IV - 120904 FCC (FRN) - 0027499805 Fire Protection, Inc. –Washington’s Most Trusted Name in Fire Safety Since 1968 17410 Ash Way, Suite 8 Lynnwood, WA 98037 david@fpiseattle.com 2 P:(425) 290-9600 F: (425) 787-9705 www.FPISEATTLE.com It is essential to understand that NFPA 72 does not require the installation of fire alarm systems or fire alarm devices. The requirement for a fire alarm system and the specific devices are driven by applicable building and fire codes (IBC & IFC) as well as local ordinances and owner’s requirements. Once a system and devices are required, then NFPA 72 provides the criteria for design and installation. Please consider the environment before printing this e-mail. Confidentiality Statement: This message is intended only for the use of the individual or entity to which it is addressed andmay contain information that is privileged, confidential, and exempt from disclosure under applicable law. If the reader of this message is not the intended recipient, or the employee or agent responsible for delivering the message to the intended recipient, you are hereby notified that any dissemination, distribution, or copying of this communication is strictly prohibited. If you have received this communication in error, please notify the sender. From: Kristin Foster <kfoster@arlingtonwa.gov> Sent: Friday, May 30, 2025 3:49 PM To: David Mow <david@fpiseattle.com> Subject: BLD6102 Expired Permit Good afternoon, I was just talking with Emily regarding this permit and have checked with the Building OƯicial and the city will require a new submittal versus paying an extension fee. You may apply online at the following link. Citizen Portal Reach out if you have any questions. Kristin Foster Permit Technician II Community and Economic Development 18204 59th Ave NE, Arlington, WA 98223 P. (360)403-3545 E.kfoster@arlingtonwa.gov 3 Permit #: 6560 Permit Date: 06/16/25 Permit Type: FIRE ALARM Project Name: BESTWORTH ROMMEL INC Applicant NICK CHANDLER W/ FIRE PROTECTION INC Name: Applicant 17410 ASH WAY, STE 8 Address: Applicant, City, LYNNWOOD, WA, 98037 State, Zip: Contact: NICK CHANDLER Phone: 425.290.9600 Email: NICK@FPISEATTLE.COM Scope of Work: NOTE: SUBMITTAL IS DUE TO PREVIOUS ISSUED PERMIT BEING EXPIRED...INSTALLATION OF A NEW UL LISTED WIRELESS FIRE ALARM COMMUNICATOR. THE NEW COMMUNICATOR WILL BE TIED INTO THE EXISTING FACP. Valuation: 500.00 Square Feet: 10000 Number of 2 Stories: Construction lA Type: Occupancy B; Business Group: ID Code: Permit Issued: 06/25/2025 Permit Expires: 12/24/2025 Form Permit FIRE ALARM Type: Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel # Address Legal Description Owner Name Owner Phone Zoning WINNERS COURT 349 Other Fabricated 31051400202900 19818 74TH AVE ENTERPRISES LLC Metal Products NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License # FIRE PROTECTION CONSTRUCTION David Mow 425-290-9600 1730 Gibson Rd UBI 601 848 346 INC CONTRACTOR FIRE PROTECTION CONSTRUCTION Labor and David Mow 425-290-9600 1730 Gibson Rd FIREPI*021ML INC CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status Final OK smoke and tamper FA00. FIRE ALARM 09/11/2025 tested all points received by 09/23/2025 09/23/2025 FIRE Approved FINAL central station FA00. FIRE ALARM 09/11/2025 Morning Requested 09/23/2025 09/23/2025 FIRE Approved FINAL FA00. FIRE ALARM 09/03/2025 09/16/2025 FIRE Canceled FINAL Plan Reviews Date Review Type Description Assigned To Review Status 06/16/2025 FIRE ALARM BUILDING Approved Fees Fee Description Notes Amount Enter 1 if permit is for: fire alarm, or fire Web Only - Fire System Plan Review $200.00 sprinkler Credit Card Service $6.00 Processing/Technology $25.00 FACP / Transmitter - Replace $125.00 Fire Alarm System Permit NFPA 72 - 105.7.3 $75.00 Credit Card Service $6.75 Total $437.75 Attached Letters Date Letter Description 06/25/2025 Building Permit 06/16/2025 Web Form - Building Application Payments Date Paid By Description Payment Type Accepted By Amount 06/16/2025 Nick Chandler 234382455 Hannah Hardwick $6.00 XBP Conf: 06/16/2025 $200.00 234382455 06/25/2025 Nick Chandler 235336654 $6.75 XBP Conf: 06/25/2025 $225.00 235336654 Outstanding Balance $0.00 Uploaded Files Date File Name 06/25/2025 27056443-2025_BLD6560_IssuedPermit.pdf 06/25/2025 27056442-20250616_BLD6560_Approved Plans.pdf 06/16/2025 57414f3fa9c3a741ed6bae6ae14383b6_6.16.25_project_scope_letter.pdf 06/16/2025 52a3c457dd310673254e03a18e9454be_bestworth_rommel_telguard.pdf 06/16/2025 8b53fafb836d54544d63616793b11880_6.16.25_fire_alarm_application-signed.pdf 06/16/2025 1663e9db69235412cc4f5d3a90888033_6.16.25_equipment_data_sheets.pdf