Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
330 S Stillaguamish AVe_BLD6703_2025
FIRE SPRINKLER PERMIT APPLICATION Community and Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 Type of Permit: ï² New Installation ï² System Modification ï² Phased Installation Property Address: Suite No.: Project Valuation: Lot #: Parcel ID No.: Preferred Contact: ï² Owner ï² Applicant ï²Contractor Project Description: Owner Name: Phone No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Applicant Name: Phone No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Contractor Name: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation ELECTRONIC FILES OF THE FOLLOW: ï² Complete and Scaled Plans ï² Hydraulic Calculations ï² Equipment Specifications for Each Fire Sprinkler Permit Application ï² Specification Sheets ï² Wiring Diagrams (Point to Point Wiring) ï² Electrical Plans, if applicable FIRE SPRINKLER SYSTEMS (105.7.1, 105.7.4, 105.7.11) ** DEVICES include separate individual portions of a Fire Sprinkler System such as: Sprinklers Heads, Risers, Valves, Pull Stations, and other such devices. (Each piece is one device) PLAN REVIEW FEES Less than $5,000.00 = $100.00 $5,000.00 & over – based on project valuation (Plan Review Fee is 65% of project valuation as calculated per Table 4-1) REV11.2020 Page 1 of 3 REINSPECTION / PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application – review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour (1 hour minimum) $75.00 Hydrostatic Pressure Test (1 test included per permit) $150.00 Cover Inspection (1 cover inspection included per permit) $75.00 Fire Pump (1 fire pump inspection per permit) inspection requires 2 hours $150.00 ï² TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 13/13R) Number of Devices** Device Fee Subtotal 1 to 2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $575.00 = $ > 300 $600.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices = $600.00 + $ = $ Hydraulically Designed Systems Yes ï² / No ï² Yes = Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ ï² NEW COMMERCIAL SYSTEM (NFPA 13/13R) Number of Devices** Device Fee Subtotal 1 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $600.00 = $ > 300 $625.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices = $625.00 + $ = $ Hydraulically Designed Systems Yes ï² / No ï² Yes = Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ ï² RESIDENTIAL (NFPA 13D) Number of Devices** Device Fee Subtotal 1 to 10 $175.00 = $ 11 to 25 $225.00 = $ 26 + $275.00 = $ * NFPA 13D SYSTEM INSTALLED (NOT REQUIRED) Permit Fee Reduced 50% = $ PERMIT FEE SUBTOTAL $ REV2022 Page 2 of 3 ï² HOOD SUPPRESSION SYSTEM Type of System No. of Units Cost per Unit Subtotal Pre-Engineered x $200.00 = $ Custom Engineered x $275.00 = $ PERMIT FEE SUBTOTAL $ ï² STANDPIPE SYSTEM Type of Standpipe No. of Units Cost per Unit Subtotal Class I – new or existing x $150.00 = $ Class II – new or existing x $150.00 = $ PERMIT FEE SUBTOTAL $ ï² FIRE PUMP Fire Pump x $300.00 each = $ PERMIT FEE SUBTOTAL $ ï² SPRAY BOOTHS (105.7) & INDUSTRIAL OVENS (105.7.7) NOTE: SEPARATE SPRINKLER PERMIT REQUIRED Type of Booth No. of Units Cost per Unit Subtotal Pre-Engineered w/documents x $150.00 = $ Site-built or used w/o documents x $250.00 = $ Industrial Oven x $250.00 = $ PERMIT FEE SUBTOTAL $ Plan review fee due at time of submittal TOTAL PERMIT FEE $ PLAN REVIEW FEE $ Processing/Technology Fee $25.00 TOTAL $ I hereby certify that I am the Owner, Applicant, Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. Signature Print Name Date REV2022 Page 3 of 3 FIELD NOTE: SCOPE OF WORK: SPRINKLER PIPING: 1) MODIFY THE EXISTING FIRE SPRINKLER SYSTEM TO ACCOMMODATE 1) ALL NEW ARM-OVER, SPRIG UP AND DROP TO BE SCH 40 BLACK FINISH 1" THE NEW WALLS AND CEILINGS. SPRINKLER PLACEMENT: GENERAL NOTES: 1) ALL NEW SPRINKLER PENDENT TO BE IN CENTER OF 2' DIRECTION AND QUARTER POINT OF 4' DIRECTION FOR 2' X 4' TILES 1) MATERIALS INSTALLATION AND DESIGN PER NFPA 13 STANDARDS 3) ALL NEW SPRINKLER MINIMUM 1'-0 AWAY AND ALIGN WITH THE LIGHTING 2) ALL AREAS PROTECTED BY A WET PIPE SYSTEM MUST BE MAINTAINED AT FIXTURES FOR GWB CEILING UNO 40 DEGREE F TO PREVENT WATER IN PIPES FROM FREEZING BY OTHERS 3) STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER SPRINKLER SPACING: PIPING BY OTHERS. 1) STANDARD COVERAGE - 15 X 15 FOR LIGHT HAZARD 4) ALL FIRE ALARMS, WIRING, MONITORING ARE BY OTHERS. CEILING GRID SHOWN ON PLAN IS SLIGHTLY 2) STANDARD COVERAGE - 130 SQ. FOR ORDINARY HAZARD OFFSET COMPARED TO EXISTING SITE CONDITION, EXCLUSIONS: FIELD VERIFY NEW HVAC LOCATION. 1) FIRE WATCH OR TEMPORARY SPRINKLER PROTECTION DURING CONSTRUCTION. 2) ACOUSTICAL CAULKING 3) FIRESTOP CAULKING 4) HEAT TRACE OR INSULATION 5) UPRIGHT SPRINKLER PROTECTION ABOVE NONCOMBUSTIBLE NEW HVAC & EXISTING LIGHT CONCEALED SPACES. CONCRETE DECK 6) PAINTING SPRINKLER PIPE WILL LIKELY CLASH, FIELD VERIFY 7) REPAIRS OR MODIFICATIONS TO THE EXISTING SYSTEM BEYOND THE & MOVE HEAD AS NEEDED. 1/4" PRE DRILLED HOLE SCOPE OF WORK 8) MODIFICATION OF EXISTING MAINS AND BRANCH LINES HILTI KWIK HUS-EZ-I 9) STRUCTURAL ANALYSIS, SEISMIC INVESTIGATION 1/4" x 1-5/8" 10) FPE AND PE REVIEW 11) UNDERGROUND WORK 3/8" ALL THREAD ROD DESIGN CRITERIA: HANGER RING TOLCO FIG. 200 PER NFPA 13 - 2019 AND CITY OF ARLINGTON 1) OFFICE - LIGHT HAZARD R 2) UPS - ORDINARY HAZARD GROUP I HILTI KWIK HUS-EZ 6' 3) SMALL ROOM PROTECTED PER NFPA13 SMALL ROOM PROVISION TYP, EXISTING LIGHT LOCATION TO HANGER TYPE P REMAIN PER PROVIDED PLAN, TENANT IMPROVEMENT: NO HYDRAULIC CALCULATION NTS FIELD VERIFY. THIS PROJECT IS A TENANT IMPROVEMENT. THE FACILITY HAS ALREADY BEEN PROTECTED BY AN EXISTING FIRE SPRINKLER SYSTEM. MODIFICATION FOR NEW WALLS, CEILINGS, AND HVAC LAYOUT WILL BE DONE WITHOUT AFFECTING THE CAPABILITY OF THE EXISTING SYSTEM HYDRAULIC DESIGN. SPRINKLER PIPE CONSTRUCTION TYPE: 1" WELDED OUTLET CONCRETE, UNOBSTRUCTED UNO ON UNOBSTRUCTED CONSTRUCTIONPLAN 72" BRAIDED HOSE SPRINKLER DEFLECTOR - 12" MAX. BELOW DECK / CEILING 2'-0 OLD STYLE WORK AREA FLEX BRACKET (INTO ACT GRID) 1/2" QR SSP TYPICAL DROP NTS KEY PLAN SCALE: NTS NORTH PROJECT SITE LEVEL1 - FIRE PROTECTION SCALE: 1/8" = 1'-0" Sprinkler Legend VICINITY MAP Symbol Manufacturer SIN Model Quantity K-Factor Type Size Response Finish Temperature Note Note2 SCALE: NTS R Reliable RA1414 F1FR56 1 5.6 Pendent ½ Quick Chrome 155°F REC. RELO. NORTH Total = 1 ABBREVIATIONS DRAWING SYMBOLS DRAWING SYMBOLS FLEX DROP LEGEND SPRINKLER PIPE LEGEND WALL LEGEND CERTIFICATION OF COMPETENCY REVISIONS CUSTOMER INFORMATION CASCADE VALLEY HOSP CT SCANNER SP SPRIG UP A 2-WAY EQ BRACING NEW MECHANICAL TEE (U-BOLT) 4' 4'-0 FLEX DROP NEW FULL HEIGHT WALL MT NEW SPRINKLER PIPE NO. DATE RN RISER NIPPLE 4' EL 4'-0 FLEX DROP, ELBOW STYLE NEW SPRINKLER PIPE PROJECT MANAGER: NICHOLAS FRESCH DR DROP A 4-WAY EQ BRACING NEW MECHANICAL TEE 330 S STILLAGUAMISH AVE MT2 6' 6'-0 FLEX DROP 1 - - PHONE: 360.899.2227 FF FINISH FLOOR EXISTING SPRINKLER PIPE NEW GRID HEIGHT WALL A 6' EL 6' EL FLEX DROP, ELBOW STYLE TS TOP OF STRUCTURE HANGER LOCATION R RELOCATE EXISTING SPRINKLER 4'BR 4'-0 FLEX DROP BRACKET EXISTING SPRINKLER PIPE ARLINGTON, WA 98223 BOS BOTTOM OF STRUCTURE BR NEW FULL HEIGHT SOFFIT HEADER SUPERINTENDENT: JOE WITTMAN BOD BOTTOM OF DECK BRANCH LINE RESTRAINT LOCATION (E) EXISTING SYSTEM COMPONENT NEW FLEX DROP BOM BOTTOM OF MAIN NEW FLEX DROP PHONE: 360.899.2238 JOB NO. 250714WH02 AHJ: CITY OF ARLINGTON BOL BOTTOM OF BRANCH LINE C CENTER LINE F FLEXIBLE COUPLING EXISTING FLEX DROP NEW LOW WALLS N OTS OPEN TO STRUCTURE EXISTING FLEX DROP (MIN. 18" BELOW FINISH CEILING) DATE 09/04/25 FP FO FIELD ORDER 12'-0 BOTTOM OF DECK ELEVATION COJ CUT ON JOB BOD EXISTING SPRINKLER LEGEND DESIGNER JAMES K. IFOW INSIDE FACE OF WALL 1 HYDRAULIC CALCULATION NODE 9-8-25 WA CL# COLUMFL795NJ JE CUMMING OFOW OUTSIDE FACE OF WALL EXISTING SSPEXISTING SSP 111 South Findlay Street PM LUKE T. 1 OF 1 NAS NO AUTO. SPRINKLER REQUIRED M1.A SPRINKLER MAIN FAB Seattle, WA 98108 UNO UNLESS NOTED OTHERWISE #1 EXISTING SSU (206) 232-8569 SCALE 1/8"=1'-0" NIC NOT IN CONTRACT SPRINKLER BRANCH LINE FAB EXISTING SSU Bulletin 074 November 2023 F1FR56 Series Quick Response Sprinklers K-factor 5.6 (80) Features • Standard coverage quick-response sprinklers • Upright, pendent, horizontal sidewall, and vertical sidewall deflectors • Low profile, compact design • Available in a wide variety of finishes Product Description Model F1FR56 Pendent Model F1FR56 Upright Reliable Model F1FR56 series sprinklers are quick-response standard spray automatic fire sprinklers utilizing a sensitive 3.0 mm glass bulb thermal element. Pendent and horizontal sidewall sprinklers may be installed exposed or surface mounted using escutcheons such as the Reliable Models B, C, or HB (reference Technical Bulletin 204). When installed recessed or concealed, the Model F1FR56 series sprinklers are specifically listed with and may only be installed with listed Reliable escutcheons and cover plates. Refer to the Model F1FR56 Vertical Sidewall Model F1FR56 technical information on the following pages for specific listings Horizontal Sidewall for recessed and concealed installations and refer to Figures 5 and 6 for dimensional information. Note: Not all versions of the product are shown. When fitted with an approved water shield, these sprinklers may considered intermediate sprinklers for use in racks, below grated walkways, and other areas where intermediate level sprinklers are required. Note: This bulletin may contain information on New and Legacy sprinklers that reflects a dimensional change only. Sprinkler Iden- Table A provides a summary of the approvals and availability of tification Number (SIN), application, performance, and listings/ specific Model F1FR series sprinkler configurations. Additional approval are not otherwise affected. Sprinklers with New frames technical information for each sprinkler model is provided on the will include the suffix “N†in the order. following pages. F1FR Series Sprinkler Summary Table A Sprinkler Sprinkler K-Factor gpm/psi1/2 Orientation Listings & Approvals Max. Working Pressure Identification Model (lpm/bar1/2) psi (bar) Number (SIN) Upright cULus, FM, LPCB, VdS, 175 (12) RA1425 Intermediate Upright EC, WM, UKCA 250 (17) (cULus only) cULus, FM, LPCB, VdS, 175 (12) Pendent RA1414 EC, WM, UKCA 250 (17) (cULus only) F1FR56 5.6 (80) Concealed Pendent cULus, VdS, EC, WM, 175 (12) RA1414 UKCA 250 (17) (cULus only) Horizontal Sidewall cULus, FM 175 (12) RA1435 cULus, FM, LPCB, Vertical Sidewall 175 (12) RA1485 UKCA www.reliablesprinkler.com Model F1FR56 Upright Sprinkler SIN RA1425 Technical Specifications Guards & Shields (New Frames) Style: Upright, Intermediate Upright Factory Water Shield (cULus, FM) Threads: 1/2†NPT or ISO 7-R1/2 F-1 Guard (cULus, FM) Nominal K-Factor: 5.6 (80 metric) F-3 Guard with Shield (cULus, FM) Max. Working Pressure: 175 psi (12 bar) Guards and Shields (Legacy Frames) 250 psi (17 bar) (cULus only) Factory Water Shield C-1 Guard (FM) Material Specifications C-3 Guard with Shield (cULus, FM) Thermal Sensor: 3 mm Glass Bulb D-1 Guard (cULus) Sprinkler Frame: Brass Alloy D-3 Guard with Shield (cULus) Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Sprinkler Wrench Load Screw: Copper Alloy Model W2 Deflector: Brass Alloy Model J (New frame with guard installed) Model JD (Legacy frame with guard Sprinkler Finishes installed) (See Table B) Listings and Approvals Sensitivity cULus Listed Quick response FM Approved LPCB Temperature Ratings VdS 135°F (57°C) EC 155°F (68°C) WM 175°F (79°C) UKCA: 0832-UKCA-CPR-S5045 200°F (93°C) 286°F (141°C) Model F1FR56 Upright Sprinkler Components and Dimensions Figure 1 3 1/4" [83mm] 1 3/8" [33mm] Load Screw Deflector Glass Bulb (3 mm) F1FR_HALF_UPR_INT 2 1/4" [58mm] Wrench Flat Cap/Seal Assembly Threads Shown with Optional Factory Installed Water Shield ( Intermediate Upright) Bulletin 074 Page 2 of 9 November 2023 www.reliablesprinkler.com Model F1FR56 Pendent Sprinkler SIN RA1414 Technical Specifications Recessed Escutcheons Style: Model F1 (cULus, LPCB, VdS, CE, WM) Pendent Model F2 (cULus, FM, LPCB, VdS, CE, Recessed Pendent WM) Concealed Pendent Model FP (cULus, VdS, CE, WM) Threads: 1/2†NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Cover Plate Max. Working Pressure: Model CCP (cULus, VdS(2), CE(2)) 175 psi (12 bar) 250 psi (17 bar) (cULus only) Guards & Shields (New Frames)(3) F-1 Guard (FM) Material Specifications F-5 Guard/Shield Kit (FM) Thermal Sensor: 3 mm Glass Bulb F-7 Guard (cULus) Sprinkler Frame: Brass Alloy F-8 Guard/Shield Kit (cULus) Cap: Bronze Alloy S-1 Shield (cULus, FM) Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Guards & Shields (Legacy Frames)(3) Deflector: Brass Alloy C-1 Guard (FM) C-5 Guard/Shield Kit (FM) Sprinkler Finishes D-1 Guard (cULus, FM) (See Table B) D-4 Guard/Shield Kit (FM) Sensitivity D-5 Guard/Shield Kit (cULus, FM) Quick response S-1 Shield (cULus, FM) Temperature Ratings(1) Sprinkler Wrenches 135°F (57°C) Model W2 (pendent) 155°F (68°C) Model W4 (recessed or concealed) 175°F (79°C) Model J (New frame with guard installed) 200°F (93°C) Model JD (Legacy frame with guard 286°F (141°C) installed) Listings and Approvals(4) cULus Listed FM Approved LPCB VdS EC WM UKCA: 0832-UKCA-CPR-S5045, 0831-UKCA-CPR-5072 (CCP) Notes: 1. 286°F (141°C) temperature rated sprinkler not listed for recessed or concealed use. 2. VdS and CE approval for CCP concealed use is for 155°C (68°C) sprinkler ONLY. 3. Not suitable for recessed or concealed pendent installations. 4. When used surface mounted or exposed. See Recessed Escutcheon and Cover Plate section for specific approvals when installed recessed or concealed. Model F1FR56 Pendent Sprinkler Components and Dimensions Figure 2 3 1/4" [83mm] Threads F1FR_HALF_PEND_INT Wrench Flat 2 1/4" [57mm] Cap/Seal Assembly Glass Bulb (3 mm) Deflector Load Screw 1" [25mm] Shown with Optional S-1 Water Shield (Ordered Separately) Note: Please refer to Figure 8 for recessed and concealed installation. Bulletin 074 Page 3 of 9 November 2023 www.reliablesprinkler.com Model F1FR56 Horizontal Sidewall Sprinkler SIN RA1435 (2) Technical Specifications Recessed Escutcheons Style: Model F1 (cULus) Horizontal Sidewall Model F2 (cULus, FM) Recessed Horizontal Sidewall Model FP (cULus) Threads: 1/2†NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Guards & Shields (New Frames)(3) F-4 Guard (FM) Max. Working Pressure: F-7 Guard (cULus) 175 psi (12 bar) Material Specifications Guards & Shields (Legacy Frames)(3) Thermal Sensor: 3 mm Glass Bulb C1 Guard (FM) Sprinkler Frame: Brass Alloy D1 Guard (cULus) Cap: Bronze Alloy Sprinkler Wrenches Sealing Washer: Nickel with PTFE Model W2 (non-recessed) Load Screw: Copper Alloy Model W4 (recessed) Deflector: Brass Alloy Model J (New frame with guard installed) Model JD (Legacy frame with guard Sprinkler Finishes installed) (See Table B) Listings and Approvals Sensitivity Quick response cULus Listed(4) FM Approved(5) Temperature Ratings (1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Notes: 1. 286°F (141°C) temperature rated sprinkler not listed for recessed use. 2. FM approved recessed installation when used with Model F2 escutcheon ONLY. 3. Not suitable for recessed horizontal sidewall installations. 4. cULus Listed for Light and Ordinary Hazard when installed exposed or surface mounted. Listed for Light Hazard ONLY when installed recessed. 5. FM Approved for Light Hazard ONLY. Model F1FR56 Horizontal Sidewall Sprinkler Components and Dimensions Figure 3 1 1/8" [28mm] Deflector Load Screw Frame Glass Bulb 2 3/4" [70mm] (3 mm) F1FR_HALF_HSW Wrench Flat Cap/Seal Assembly Threads Note: Please refer to Figure 9 for recessed installation. Bulletin 074 Page 4 of 9 November 2023 www.reliablesprinkler.com Model F1FR56 Vertical Sidewall Sprinkler SIN RA1485 Technical Specifications Guards & Shields (New Frames) Style: F-2 Guard (FM) Upright Vertical Sidewall Guards & Shields (Legacy Frames) Pendent Vertical Sidewall C1 Guard (FM) Threads: 1/2†NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Sprinkler Wrenches Max. Working Pressure: 175 psi (12 bar) Model W2 Model J (New frame with guard installed) Material Specifications Model JD (Legacy frame with guard Thermal Sensor: 3 mm Glass Bulb installed) Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Listings and Approvals(1) cULus Listed Load Screw: Copper Alloy FM Approved Deflector: Brass Alloy (2) LPCB UKCA: 0832-UKCA-CPR-S5045 Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Notes: 1. Listed and approved for Light Hazard ONLY. 2. LPCB approved for use in pendent position ONLY. Model F1FR56 Vertical Sprinkler Components and Dimensions Figure 4 Deflector Load Screw 1 1/2" [38mm] Frame Glass Bulb (3 mm) F1FR_HALF_VSW 2 1/4" [57mm] Wrench Flat Cap/Seal Assembly Threads Bulletin 074 Page 5 of 9 November 2023 www.reliablesprinkler.com Recessed and Concealed Installation: Pendent Sprinklers Figure 5 2-1/4" 2-1/4" (57 mm) Dia. (57 mm) Dia. Hole in Ceiling Hole in Ceiling 1-15/16" 1-15/16" (49 mm) Dia. (49 mm) Dia. Reducing Reducing Fitting Fitting Face of Fitting Face of Fitting to Face of Ceiling to Face of Ceiling 1-1/8" (29 mm) at 7/8" (22 mm) at Max. Recess Max. Recess 3/8" (10 mm) at 3/8" (10 mm) at Min. Recess Min. Recess 1-3/4" 1-3/4" (44 mm) 1" (44 mm) 1-1/4" (25 mm) (32 mm) Minimum Maximum Minimum Maximum Recess 2-7/8" (72 mm) Dia. Recess Recess 2-7/8" (72 mm) Dia. Recess Models F1 & F1FR Pendent Sprinkler Models F1 & F1FR Pendent Sprinkler with Model F1 Recessed Escutcheon with Model F2 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment 1/2" (13mm) Nominal Adjustment F1_REC_PEND_CCP 2-1/2" 2-1/2" (64 mm) Dia. (64 mm) Dia. Hole in Ceiling Hole in Ceiling 2-5/16" 2-5/16" (59 mm) Dia. (59 mm) Dia. Reducing Reducing Fitting Fitting Face of Fitting Face of Fitting to Face of Ceiling to Face of Ceiling Vented Cup Vented Cup 1-1/2" (38 mm) at 1-1/2" (38 mm) at Max. Recess Max. Recess 1" (25 mm) at 1" (25 mm) at Min. Recess Min. Recess 1" 1" (25 mm) 1/2" (25 mm) 1/2" (12 mm) (12 mm) Minimum Minimum 3-3/16" (78 mm) Dia. Recess Maximum Recess Maximum Recess 3-5/16" (84 mm) Dia. Recess Models F1 & F1FR Pendent Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Model F1FR56 CCP Conical Concealed Sprinkler 1/2" (13mm) Nominal Adjustment Note: Model FP recessed assemblies may not be used where the (Nominal Cover Plate Projection is 1" (25 mm)) pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model FP cup Note: Model CCP concealed assemblies may not be used where are unobstructed following installation. the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model CCP cup are unobstructed following installation. FP Escutcheon F1 Escutcheon CCP Cover Plate (F2 Similar) Bulletin 074 Page 6 of 9 November 2023 www.reliablesprinkler.com Recessed Installation: Horizontal Sidewall Sprinklers Figure 6 1/2" (12 mm) Reducing +/- 3/8" (10 mm) 1-3/8" (35 mm) Maximum Recess Fitting Face of fitting to face of wall 4" - 12" (102 mm - 305 mm) Deflector to ceiling 2-1/4" 1-15/16" 2-7/8" (57 mm) (49 mm) (73 mm) Dia. Dia. Dia. Hole 9/16" [14mm] F1 Recessed escutcheon 3/4" (19 mm) Adjustment 2 1/8" (54 mm) Minimum Recess Model F1FR Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment F1FR_REC_HSW 3/8" (16 mm) Reducing +/- 1/4" (6 mm) 1-5/8" (42 mm) Maximum Recess Fitting Face of fitting to face of wall 4" - 12" (102 mm - 305 mm) Deflector to ceiling 2-1/4" 1-15/16" 2-7/8" (57 mm) (49 mm) (73 mm) Dia. DIA. Dia. Hole 9/16" [14mm] F2 Recessed escutcheon 1/2" (13 mm) Adjustment 2-1/8" (54 mm) Minimum Recess Model F1FR Horizontal Sidewall Sprinkler with Model F2 Recessed Escutcheon 1/2" (13mm) Nominal Adjustment 1-1/4" (32 mm) Reducing +/- 1/4" (6 mm) 7/8" (22 mm) Maximum Recess Fitting Face of fitting to face of wall 4" - 12" (102 mm - 305 mm) Deflector to ceiling 2-5/8" 2-5/16" 3-1/4" (67 mm) (58 mm) (83 mm) Dia Dia. Dia. Hole. 9/16" [14mm] Vented Cup 1-3/8" (35 mm) Minimum Recess Model F1FR Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Note: Model FP recessed assemblies may not be used where the pressure in the space behind the sprinkler is positive with respect to the space in the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. Bulletin 074 Page 7 of 9 November 2023 www.reliablesprinkler.com Wrenches Model W2 (upright, pendent) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed, similar but with zinc finish) Model W4 (recessed, concealed pendent) Finishes(1) Table B Standard Finishes Special Application Finishes F1, F2 and FP(2) CCP Cover F1, F2 and FP(2) Sprinkler Sprinkler CCP Cover Plate(2) Escutcheons Plate(2) Escutcheons Bronze Brass Chrome Electroless Nickel PTFE(3)(4) Bright Brass Bright Brass Chrome Chrome White Paint Bright Brass(5) Satin Chrome Satin Chrome White Polyester(3) White Polyester Satin Chrome Custom Color Polyester Custom Color Paint Custom Color Polyester(3) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Model FP escutcheons and Model CCP sprinklers utilize a galvanized steel cup with a finished trim ring or cover plate. 3. cULus Listed as corrosion resistant. 4. FM Approved as corrosion resistant. 5. For 200°F (93°C) maximum temperature rated sprinklers only. Installation Maintenance Model F1FR Series sprinklers must be installed in accordance with Reliable Model F1FR series sprinklers should be inspected and NFPA13 and the requirements of all applicable authorities having the sprinkler system maintained in accordance with NFPA 25, as jurisdiction. Model F1FR Series sprinklers must be installed with well as the requirements of any Authorities Having Jurisdiction. the Reliable sprinkler installation wrench identified in this Bulletin. Prior to installation, sprinklers should remain in the original Any other wrench may damage the sprinkler. The Models W2 and cartons and packaging until used. This will minimize the potential W4 wrenches have two sets of jaws. Use the smallest set of jaws for damage to sprinklers that could cause improper operation or that fit on the wrench flats of the sprinkler. A leak tight sprinkler non-operation. joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 Do not clean sprinklers with soap and water, ammonia liquid or N.m). Do not tighten sprinklers over the maximum recommended any other cleaning fluids. Remove dust by gentle vacuuming installation torque. Exceeding the maximum recommended without touching the sprinkler. installation torque may cause leakage or impairment of the sprinkler. Replace any sprinkler which has been painted (other than factory applied). A stock of spare sprinklers should be maintained to Glass bulb sprinklers have orange bulb protectors or protective allow quick replacement of damaged or operated sprinklers. caps to minimize bulb damage during shipping, handling and Failure to properly maintain sprinklers may result in inadvertent installation. Reliable sprinkler installation wrenches are designed operation or non-operation during a fire event. to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Bulletin 074 Page 8 of 9 November 2023 www.reliablesprinkler.com Guarantee For the guarantee, terms, and conditions, visit www. reliablesprinkler.com. Ordering Information Specify the following when ordering: Model • F1FR56 Deflector/Orientation • Upright • Intermediate Upright • Pendent • CCP Concealed Pendent • Horizontal Sidewall • Vertical Sidewall Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table B Recessed Escutcheon(1)(2) • F1 • F2 • FP Escutcheon Finish • See Table B CCP Cover Plate Temperature Rating • 135°F (57°C) [For use with 135°F (57°C) and 155°F (68°C) sprinklers.] • 165°F (74°C) [For use with 175°F (79°C) and 200°F (93°C) sprinklers.] CCP Cover Plate Finish • See Table B Sprinkler Wrench • Model W2 • Model W4 (recessed, concealed) • Model J (New frame with guard installed) • Model JD (Legacy frame with guard installed) Notes: 1. 286°F (141°C) sprinklers are not listed to be used recessed or concealed. 2. For FM, recessed sprinklers must use the Model F2 escutcheon. P/N 9999970623 Bulletin 074 Page 9 of 9 November 2023 www.reliablesprinkler.com FLEXHEAD® FLE XIBLE FIRE SPRINK LER C ONNEC T IONS THE FLEXHEAD ADVANTAGE 02 INSTALLATION COMPARISON 03 NFPA 13 CODE LANGUAGE & 04 SEISMIC QUALIFICATIONS PRODUCTS 06 FRICTION LOSS DATA & SPECIFICATIONS 10 FLEXHEAD CEILING DETAILS 12 BRACKET SPECIFICATION SHEET 14 FLEXHEAD COMMERCIAL PRODUCTS 15 FLEXHEAD STANDARD SPECIFICATIONS 16 ANVIL BRANDS 18 CUSTOMER SERVICE CENTERS 20 FLEXHEAD® The Flexhead® Advantage QUALITY FEATURES • BEST CORROSION RESISTANCE • Is seismically qualified, eliminating the need for Made from 100% 304 stainless steel an oversized ring around the sprinkler head in seismic areas • EXCELLENT FRICTION LOSS VALUES One-inch true-bore ID reducing the need • Has the same product design that is dual listed to upsize mains and branch lines, 1¼" by both UL and FM ID available • Can be produced to meet all your project • PRESSURE SURGE PROTECTION requirements Fully braided connection improves pressure • Hoses have serial identification with complete capability and prevents hose damage audit tracking of finished goods • HIGHEST MAXIMUM WORKING PRESSURE • Hose has comprehensive limited warranty backed by an A++ insurance company Available up to 300 PSI • NO O-RINGS OR GASKETS • Offers a variety of flexible fire sprinkler connections, suspended ceilings, gypsum Welded connections reduce potential board ceilings, freezer, coolers, institutional leak points at the inlet and outlet fitting applications, cleanroom and duct applications • TIGHTEST THREAD TOLERANCES Outlet fitting threads are machined from • Offers 1.25" FlexHead® hose for superior friction loss numbers solid bar stock reducing potential leaks at the sprinkler head fit-up • The 3" Tall MPT Bracket allows the sprinkler to • EXTRA STABILITY BRACKET install the FlexHead® system without touching the ceiling tile A full 6-inch base to stabilize the sprinkler head during installation, pressurization or activation 2 BUILDING CONNECTIONS THAT LAST Connect sprinkler heads to sub-mains at least four times faster. FlexHead systems connect sprinkler heads to sprinkler sub-mains in about a quarter of the time it takes to install hard pipe. Expect even greater savings in retrofits, where FlexHead installs six to seven times faster than hard pipe. Increase productivity with the ease of installation, no need to install hangers and there is no on-site assembly required. Every sprinkler connection is a finished, pre-constructed assembly, from the 1" pipe connector to the sprinkler head outlet. In addition, FlexHead provides seismic protection to sprinkler heads allowing for deflection during a seismic event. NEW CONSTRUCTION COMPARISON RETROFIT COMPARISON During a typical installation, a minimum of four During a typical installation, a minimum of six FlexHeads FlexHeads can be installed in the same time it takes can be installed in the same time it takes to do one to do one hard-pipe. hard-pipe. Retrofits in less time. HEADS INSTALLED 4 FLEXHEADS HEADS INSTALLED 4 FLEXHEADS Four Flexhead Six Flexhead One Hard-Pipe One Hard-Pipe 1 HARD-PIPE 1 HARD-PIPE WANT PINPOINT LOCATIONS? NO PROBLEM. RETROFITS IN LESS TIME. The design makes it easy to accurately locate sprinkler heads Need to comply to code in unsprinklered buildings? every time. If the spec calls for center-of-tile placement, you In contrast to costly and labor-intensive hard-pipe retrofits, can do it with ease. In fact, you get center-of-tile placement FlexHead connections install in minutes in even the most every install whether the spec calls for it or not. It takes one restrictive spaces. more headache out of specifying and bidding. SHORTEN YOUR TIME TO OCCUPANCY. ACCOMMODATE FLOOR PLAN CHANGES. Faster installation times help get end-users into their spaces Need to relocate sprinkler heads? No problem. With its more quickly—and get installers on their next projects faster. built-in flexibility it’s much easier to move heads to a new FlexHead connections virtually eliminate punch list items location to accommodate new layouts or uses of the space. commonly found with hard-pipe armovers. 3 FLEXHEAD® NFPA 13 CODE LANGUAGES & SEISMIC QUALIFICATION NFPA 13 STANDARDS FOR INSTALLATION OF SPRINKLER SYSTEMS 2019 17 .4.1.3.3* Flexible Sprinkler Hose Fittings 17.4.1.3.3.1 Listed flexible sprinkler hose fittings and their anchoring components intended for use in installations connecting the sprinkler system piping to sprinklers shall be installed in accordance with the requirements of the listing, including any installation instructions. 17.4.1.3.3.2 When installed and supported by suspended ceilings, the ceiling shall meet ASTM C635/C635M, Standard Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-In Panel Ceilings, and shall be installed in accordance with ASTM C636/C636M, Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels. 17.4.1.3.3.3* Where flexible sprinkler hose fittings exceed 6 ft (1.8 m) in length and are supported by a suspended ceiling in accordance with 17.4.1.3.3.2, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft (1.8 m) . 17 .4.1.3.3.4* Where flexible sprinkler hose fittings are used to connect sprinklers to branch lines in suspended ceilings, a label limiting relocation of the sprinkler shall be provided on the anchoring component. Reproduced with permission of NFPA from NFPA 13, Standard or the Installation of Sprinkler Systems, 2019 edition. Copyright© 2018, National Fire Protection Association. For a full copy of NFPA 13, please go to www.nfpa.org. This material is not affiliated with nor has it been reviewed or approved by the NFPA. 4 BUILDING CONNECTIONS THAT LAST FLEXHEAD® SATISFIES SEISMIC CODE REQUIREMENTS The FlexHead® hose allows the head to move in any direction during a seismic event without causing damage to the sprinkler system. FlexHead® Mounting Bracket FlexHead® satisfactorily completed full-scale seismic qualification testing at the Structural Engineering Earthquake Simulation Laboratory located at the State University of New York at Buffalo. Tests were conducted using the International Code Council (ICC) acceptance criteria “ICC-ES AC-156 Seismic Qualification Testing of Nonstructural Componentsâ€. • More than 90% of the states in the U.S. are adopting the • In Seismic Design Categories D, E & F, suspended ceilings International Building Code (IBC) that address, among are to be designed and installed in accordance with CISCA other things, the installation of fire sprinkler systems in recommendations for seismic Zones 3 and 4 with some seismic zones. additional requirements. Except where rigid braces are used to limit lateral deflections, sprinkler heads and other • The latest version of the IBC defers to ASCE 7 and ASTM penetrations shall have a 2-inch oversized ring, sleeve, or E580/580M-17 for the sprinkler/ceiling design in Seismic adapter through the ceiling to allow for free movement of at Design Categories C and D, E & F. least 1 inch of ceiling movement in all horizontal directions. • In Seismic Design Category C, suspended ceilings are to be designed and installed in accordance with • Flexible sprinkler connection provide characteristics that exceed the most stringent seismic code requirements. Ceilings & Interior Systems Construction Association The flexibility of the hose allows the head to move with (CISCA) recommendations for Zones 0-2; and sprinkler the ceiling in any direction during a seismic event without heads and other penetrations shall have a minimum causing damage to the sprinkler system. of 1â„4 inch clearance on all sides. 5 FLEXHEAD® FLEXIBLE FIRE SPRINKLER CONNECTIONS We invented the concept of Flexible Fire Protectionâ„¢. All our flexible sprinkler pipe and connections are UL Listed and/or FM Approved. THE ONLY PRODUCT THAT: • Has undergone full-scale head deployment testing • Is seismically qualified for use in Seismic Design Categories D, E & F • Is made of 100% 304 stainless steel including end fittings • Is fully welded without the need for o-rings or gaskets FLEXHEAD®FLEXIBLE FIRE INSTITUTIONAL FLEXIBLE SPRINKLER CONNECTIONS FIRE SPRINKLER • UL Listed/ FM Approved CONNECTIONS • Undergone full-scale head deployment testing • Available in hose lengths from 24" - 72" Designed to be installed in concrete walls • Seismically qualified for use in Seismic or ceiling penetrations Design Categories C, D, E & F • Available with open hub UHO-3 bracket for • Made of 100% 304 stainless steel easier installation including end fittings • Easy installation in tight spaces • Every FlexHead hose is leak tested before shipment • UL Listed / FM Approved • Fully welded 304SS hose doesn't contain any O-rings or gaskets 6 BUILDING CONNECTIONS THAT LAST FLEXIBLE FIRE SPRINKLER CONNECTIONS FlexHead® systems connect sprinkler heads to sub-mains at least four times faster than hard pipe. Delivers even greater savings in retrofits. All our flexible sprinkler pipe and connections are UL Listed and/or FM Approved. SUPERFLEX® FLEXIBLE FIRE SUPERFLEX® FLEXIBLE FIRE SPRINKLER CONNECTIONS SPRINKLER CONNECTION • No need to measure or count the number of WITH PATENTED SLT bends, 72" SuperFlex hose is UL listed for up TECHNOLOGY to (12) bends • Fast and easy installation with 1" integrated • Increased bends create more flexibility SlideLOK® Coupling during installation • Comes fully assembled • All Welded, no o-rings • UL listed for 2" bend radius, up to 12 bends • Quick inspections and sign offs by AHJ’s for per hose* (72"hose) final walkthrough • Eliminates taping or doping of threaded fittings • Available with MPT (Multi-positional tail) mounting bracket. No need to touch the ceiling • Flexible design provides versatility for changes tile during installation. in plan • Also available with Adjustable ADO24BKT3 • Installs on a standard 1" Welded Outlet mounting bracket. • UL Listed / FM Approved • UL Listed / FM Approved 1.25" I.D. HOSE WITH BEST FLEXIBLE FIRE SPRINKLER FLOW CHARACTERISTICS DRY PENDENT SYSTEM • Best flow characteristics for flexible drops • Suitable for wet sprinkler systems in the industry with a dry pendent sprinkler head (Dry pendant sprinkler head not included) • 1¼" NPT Standard, and 1¼" SLT integrated coupling option available • Mounts on the top of freezer or sidewall • Great for tenant improvement projects, • Moves and flexes along with the structure similar flow characteristic to 1" pipe protecting the integrity of the freezer seal • FM Approved • Now available with a Drain Tee • FM Approved 7 FLEXHEAD® FLEXIBLE FIRE SPRINKLER CONNECTIONS We invented the concept of Flexible Fire Protectionâ„¢. All our flexible sprinkler pipe and connections are UL Listed and/or FM Approved. NO TOUCH CEILING TILE TALL ARMSTRONG® TECHZONEâ„¢ BRACKET MOUNTING SYSTEM BRACKET MOUNTING SYSTEM (MPT24BKT1) • The mounting bracket is specifically designed • Superior height allows the “MPT†to to be compatible with the Armstrong®TechZoneâ„¢ be mounted without pre-installing the suspended ceiling systems ceiling tile and comes out of the box fully • FlexHead TechZoneâ„¢ mounting bracelets assembled at 24" allow for quick TechZoneâ„¢ ceiling installations. • Within seconds the MPT Bracket can be The FlexHead TechZoneâ„¢ system installs in a adjusted from 24" to 16†to 14 ½" in length quarter of the time compared to typical black accommodating numerous applications pipe armovers. without additional fabrication • Allows for rapid installation or relocation of • Adjustable Open Hub allows for swift & sprinkler heads in suspended ceilings accurate repositioning at the 1/4 points • UL Listed / FM Approved • UL Listed / FM Approved UHO-3 THREADED ROD DRY WALL CEILING AND INSTALLATION SIDEWALL INSTALLATION • “Open Hub†design for quick and easy (ADO16BKT3 & ADO24BKT3) installation • FlexHead ADO16BKT3 and ADO24BKT3 can be • Can be installed with " or ½" threaded rod installed in hard ceilings or sidewall applications. attachments • For use with FlexHead hose model numbers 20XX, • The " rod is FM approved to be installed up to 20XXH, where XX designates hose length in inches. 4ft off the structure and the ½" threaded rod up • FM Approved to 6ft off the structure • Good option for temporary fire protection • Ideal for shell applications; easily transitions from UHO-3 to suspended ceiling bracket • FM Approved 8 BUILDING CONNECTIONS THAT LAST FLEXIBLE FIRE SPRINKLER CONNECTIONS Whether your application is commercial, industrial, clean room, or institutional, FlexHead® flexible sprinkler systems can save you time and money by offering reliable, highly efficient, seismically qualified, and environmentally responsible products DROP NIPPLE FLEXIBLE LOW-PROFILE FLEXIBLE FIRE ARMSTRONG® TECHZONEâ„¢ SPRINKLER CONNECTIONS SPRINKLER CONNECTIONS BRACKET MOUNTING SYSTEM FOR ANVIL-STRUTâ„¢ FOR ANVIL-STRUTâ„¢ • Attach to structure with Anvil-Strutâ„¢ • Perfect for applications where you and pipe clamp have limited space • Drop nipple with reducer (not included) • The FlexHead Low-Profile Model uses • Perfect for applications where you have a traditional Anvil-Strutâ„¢ Channel (not included) to secure the FlexHead sprinkler hose to the concrete deck above the ceiling which secures building structure the flexible hose to the building structure. • FM Approved • This model will have a 1 inch female outlet • FM Approved INDUSTRIAL/DUCT CLASS 100 CLEANROOM FLEXIBLE FIRE SPRINKLERS FLEXIBLE FIRE SPRINKLER CONNECTIONS CONNECTIONS • FlexHead flexible sprinkler systems have been • Custom manufactured for “walkable" protecting exhaust ducts in semi-conductor/ cleanroom ceiling systems in Class electronics facilities 100 cleanrooms. for more than thirty years • 100% stainless-steel, one-piece system is • Quick installation, install in minutes leak-tested prior to shipping • No need for inspection port • Allows quick and easy relocation when floor plan changes due to reconfiguration of tool • Available in Steel, FRP, Polypropylene, and PVC layout • Flexible hoses allow for independent motion • Allows for independent motion (sway) (sway) between duct and water main to between ceiling grid and water main to compensate for duct vibration and during accommodate filter vibration and during possible seismic activity—eliminating potential possible seismic activity. leaks. • Eliminates potential leaks and protecting • Allows for quick and easy inspection gel seals of sprinkler heads • Eliminates ceiling stress/leaks due to • FM Approved miss-aligned hard-pipe installation • FM Approved 9 FLEXHEAD® FRICTION LOSS DATA & SPECIFICATIONS Maximum Number of Minimum Bend Radius Equivalent Length of 1in. Diameter Schedule 40 Pipe (Ft) Max Rated Pressure 90Ëš Bends Outlet Hose Model Orifice Assembly Number Size Length FM FM UL UL FM UL FM LU 5.6k-factor 8.0k-factor 11.2k-factor 14.0k-factor 16.8k-factor 22.4k-factor in (cm) in (mm) in (mm) in (mm) in (mm) in (mm) Ft (mm) Ft (mm) Ft (mm) Ft (mm) Ft (mm) Ft (mm) Ft (mm) PSI/Kpa PSI/Kpa SUPERFLEX® 1" INTERNAL DIAMETER (I.D.) HOSE SERIES (Data equivalent for all end connection 1" NPT, 1" Cut Groove and SLT) 2036SF-50 36 (914) 5 2 30 (9.1) 16.2 (4.9) 16.9 (5.1) 11.5 (3.5) – – – 1â„ 2048SF-50 2 (1.27) 48 (1219) 7 (178) 2 (50.8) 8 3 47 (14.3) 28.7 (8.7) 29.3 (8.9) 15.4 (4.7) – – – 2072SF-50 72 (1828) 12 4 71 (21.6) 53.9 (16.4) 54.3 (16.5) 23.2 (7) – – – 2036SF-75 36 (914) 5 2 29 (8.8) – 21.5 (6.5) 21.6 (6.5) 21.8 (6.6) 22 (6.7) – 3â„ 2048SF-75 4 (1.90) 48 (1219) 7 (178) 2 (50.8) 8 3 44 (13.4) – 30.5 (9.2) 30.6 (9.3) 31.1 (9.4) 30.8 (9.3) – 2072SF-75 72 (1828) 12 4 70 (21.3) – 48.5 (14.7) 48.8 (14.8) 49.9 (15.2) 48.6 (14.8) – FLEXHEAD STANDARD TALL 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024T-50 24 (610) 3 1 11 (3.4) 18.4 (5.6) 7.7 (2.3) 7.6 (2.3) – – – 2036T-50 36 (914) 3 2 16 (4.9) 26.6 (8.1) 11.5 (3.5) 11.5 (3.5) – – – 1â„ 2048T-50 2 48 (1219) 8 3 4 3 24 (7.3) 30.3 (9.2) 15.3 (4.6) 15.4 (4.7) – – – 175 175 (1.27) (200) (76.2) (1205) (1205) 2060T-50 60 (1524) 4 4 29 (8.8) 35.8 (10.9) 19.1 (5.8) 19.3 (5.8) – – – 2072T-50 72 (1828) 4 4 35 (10.7) 45.6 (13.9) 23.0 (7) 23.2 (7) – – – 2024T-75 24 (610) 3 1 12 (3.7) – 7.3 (2.2) 5.9 (1.8) 14.7 (4.5) 7.1 (2.1) – 2036T-75 36 (914) 3 2 18 (5.5) – 21.5 (6.5) 10.4 (3.1) 21.8 (6.6) 10.9 (3.3) – 3â„ 2048T-75 4 48 (1219) 8 3 4 3 23 (7) – 30.5 (9.3) 14.9 (4.5) 29 (8.8) 14.8 (4.5) – 175 175 (1.90) (200) (76.2) (1205) (1205) 2060T-75 60 (1524) 4 4 29 (8.8) – 39.5 (12) 19.4 (4.5) 36.1 (11) 18.7 (5.6) – 2072T-75 72 (1828) 4 4 32 (9.8) – 48.5 (14.7) 24.0 (7.3) 43.2 (13.1) 22.6 (6.8) – FLEXHEAD® STANDARD TALL ELBOW 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024ET-50 24 (610) 3 1 19 (5.8) 26.4 (8.0) 6.8 (2) 7.4 (2.2) – – – 2036ET-50 36 (914) 3 2 23 (7.0) 30.1 (9.2) 11.8 (3.6) 12.5 (3.8) – – – 1â„ 2048ET-50 2 48 (1219) 8 3 4 3 27 (8.2) 33.8 (10.3) 16.9 (5.1) 17.6 (5.3) – – – 175 175 (1.27) (200) (76.2) (1205) (1205) 2060ET-50 60 (1524) 4 4 32 (9.8) 37.5 (11.4) 21.9 (6.6) 22.7 (6.9) – – – 2072ET-50 72 (1828) 4 4 35 (10.7) 41.2 (12.5) 27.0 (8.2) 27.8 (8.4) – – – 2024ET-75 24 (610) 3 1 18 (5.5) - 8.8 (2.6) 8.7 (2.6) 14.7 (4.5) 8.2 (2.5) – 2036ET-75 36 (914) 3 2 23 (7.0) – 25.5 (7.7) 14.2 (4.2) 21.8 (6.6) 13 (3.9) – 3â„ 2048ET-75 4 48 (1219) 8 3 4 3 23 (7.0) – 32.9 (10) 18.4 (5.6) 29 (8.8) 17.8 (5.4) – 175 175 (1.90) (200) (76.2) (1205) (1205) 2060ET-75 60 (1524) 4 4 29 (8.8) – 40.6 (12.3) 22.7 (6.9) 36.1 (11.0) 22.6 (6.8) – 2072ET-75 72 (1828) 4 4 32 (9.8) – 48.5 (14.7) 27.0 (8.2) 43.2 (13.1) 27.5 (8.3) – FLEXHEAD® HIGH PRESSURE 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024H-50 24 (610) 3 2 11 (3.4) 18.4 (5.6) 7.7 (2.3) 7.6 (2.3) – – – 2036H-50 36 (914) 3 3 16 (4.9) 26.6 (8.1) 11.5 (3.5) 11.5 (3.5) – – – 1â„ 2048H-50 2 48 (1219) 8 3 4 4 24 (7.3) 30.3 (9.2) 15.3 (4.6) 15.4 (4.7) – – – 300 300 (1.27) (200) (76.2) (2068) (2068) 2060H-50 60 (1524) 4 4 29 (8.8) 35.8 (10.9) 19.1 (5.8) 19.3 (5.8) – – – 2072H50 72 (1828) 4 4 35 (10.7) 45.6(12.5) 23.0 (7) 23.2 (7) – – – 2024ET-75 24 (610) 3 1 12 (3.7) - 14.7 (4.5) 6.8 (2.0) 14.7 (4.5) 8.2 (2.1) – 2036ET-75 36 (914) 3 2 18 (5.5) – 21.5 (6.5) 11.4 (3.4) 21.8 (6.6) 10.9 (3.3) – 3â„ 2048ET-75 4 48 (1219) 8 3 4 3 23 (7.0) – 30.5 (9.2) 16.0 (5.1) 29 (8.8) 14.8 (4.5) – 300 300 (1.90) (200) (76.2) (2068) (2068) 2060ET-75 60 (1524) 4 4 29 (8.8) – 39.5 (12) 20.6 (6.2) 36.1 (11.0) 18.7 (5.7) – 2072ET-75 72 (1828) 4 4 32 (9.8) – 48.5 (14.7) 25.3 (7.7) 43.2 (13.1) 22.6 (6.5) – 10 BUILDING CONNECTIONS THAT LAST FRICTION LOSS DATA & SPECIFICATIONS (CONT’D) Maximum Number of Minimum Bend Radius Equivalent Length of 1in. Diameter Schedule 40 Pipe (Ft) Max Rated Pressure 90Ëš Bends Outlet Hose Model Orifice Assembly Number Size Length FM FM UL UL FM UL FM LU 5.6k-factor 8.0k-factor 11.2k-factor 14.0k-factor 16.8k-factor 22.4k-factor in (cm) in (mm) in (mm) in (mm) in (mm) in (mm) Ft (mm) Ft (mm) Ft (mm) Ft (mm) Ft (mm) Ft (mm) Ft (mm) PSI/Kpa PSI/Kpa FLEXHEAD® HIGH PRESSURE ELBOW 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024HE-50 24 (610) 3 2 19 (5.8) 14.7 (4.5) 6.8 (2) 7.4 (2.2) – – – 2036HE-50 36 (914) 3 3 23 (7.0) 21.8 (6.6) 11.8 (3.6) 12.5 (3.8) – – – 1 8 3 300 300 2048HE-50 â„2 (1.27) 48 (1219) 4 4 27 (8.2) 29.0 (8.8) 16.9 (5.1) 17.6 (5.3) – – – (200) (76.3) (2068) (2068) 2060HE-50 60 (1524) 4 4 32 (9.8) 36.1 (11) 21.9 (6.6) 22.7 (6.9) – – – 2072HE-50 72 (1828) 4 4 35 (10.7) 43.2 (13.1) 27.0 (8.2) 27.8 (8.4) – – – 2024HE-75 24 (610) 3 2 18 (5.5) - 14.7 (4.5) - 14.7 (4.5) 8.2 (4.5) – 2036HE-75 36 (914) 3 3 23 (7.0) - 25.2 (7.7) 26 (7.9) 21.8 (8.6) 13 (3.9) – 3â„ 2048HE-75 4 48 (1219) 8 3 4 4 23 (7.0) – 32.9 (10) 33 (10) 29 (8.8) 17.8 (5.4) – 300 300 (1.90) (200) (76.3) (2068) (2068) 2060HE-75 60 (1524) 4 4 29 (8.8) - 40.5 (12.3) 40 (12.2) 36.1 (11.0) 22.6 (6.8) - 2072HE-75 72 (1828) 4 4 32 (9.8) - 48.5 (14.8) 47 (14.3) 43.2 (13.1) 27.5 (8.3) - FLEXHEAD® DRY PENDENT SYSTEM 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024-DPS 24 (610) - 1 - 18.4 (5.6) 7.7 (2.3) 7.6 (2.3) – 7.1 (2.1) 10.7 (3.3) 2036-DPS 36 (914) - 2 - 26.6 (8.1) 11.5 (3.5) 11.5 (3.5) – 10.9 (3.3) 15.1 (4.6) 1 7 175 2048-DPS 48 (1219) - - 3 - 30.3 (9.2) 15.3 (4.7) 15.4 (4.7) – 14.8 (4.5) 21.5 (6.5) - (2.54) (200) (1205) 2060-DPS 60 (1524) - 4 - 35.8 (10.9) 19.1 (5.8) 19.3 (5.9) – 18.7 (5.7) 25.3 (7.7) 2072-DPS 72 (1828) - 4 - 45.6 (13.9) 23.0 (7) 32.2 (7) – 22.6 (6.9) 26.9 (8.1) FLEXHEAD® INSTITUTIONAL 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024I 24 (610) 3 1 11 (3.4) 18.4 (5.6) – – – – – 2036I 36 (914) 3 3 16 (4.9) 26.6 (8.1) – – – – – 1â„ 2048I 2 48 (1219) 8 3 4 4 24 (7.3) 30.3 (9.2) – – – – – 175 175 (1.27) (200) (76.2) (1205) (1205) 2060I 60 (1524) 4 4 29 (8.8) 35.8 (10.9) – – – – – 2072ET-50 72 (1828) 4 4 35 (10.7) 45.6 (13.9) – – – – – 2024I 24 (610) 3 1 12 (3.7) - – – 11.6 (3.5) – – 2036I 36 (914) 3 2 18 (5.5) – – – 16 (4.9) – – 3â„ 2048I 4 48 (1219) 8 3 4 3 23 (7.0) – – – 17.9 (5.4) – – 175 175 (1.90) (200) (76.2) (1205) (1205) 2060I 60 (1524) 4 4 29 (8.8) – – – 24.7 (7.5) – – 2072I 72 (1828) 4 4 32 (9.8) – – – 28.9 (8.8) – – Notes: Model Numbers: • “SF†designates SuperFlex® Hose series. • “ESF†designates SuperFlex® Elbow Hose series. • “E†designates elbow drop hose series • â€T†designates straight tall style hose • “ET†designates elbow tall style hose series. • “H†designates high pressure 300psi working pressure hose series. • “HE†designates high pressure 300psi elbow hose series. • “DPS†designates dry pendant system. • “DT†designates drain tee hose series used in dry pendent/freezer application. • “SLT†designates SlideLOK® technology. • “DPS†and “DT†models are approved for use in cold storage application (Freezer, Cold Chamber) and combine an approved flexible sprinkler hose and an approved dry pendent sprinkler. UHO-1 or UHO-3 is required to connect the flexible sprinkler hose to the dry sprinkler. • “I†indicates instiutional flexible hose. • “A†indicates models for use with Amerlux Ceiling System. • “50†designates 1â„2" Outlet Hose series. The “75†designates 3â„4†Outlet Hose series. Inlet size 1â€. • Max Ambient Temperature Rating on all model numbers are 300Ëš F (148Ëš C). • Equivalent lengths are shown with maximum number of 90Ëš bends at the minimum bend radius per agency. 2-45Ëš or 3-30Ëš bend equal 1-90Ëš bend. Different values were obtained by FM and UL due to the difference in minimum bend radius, testing protocol and calculation methods. Please see individual standards for more information relative to Friction Loss (equivalent length of pipe). • All hoses require a minimum of one bend for installation. Bend radius tool available for 3†bend “T†hose, “SF†hose does not require bend radius tool. • FM equivalent length calculation includes Sprinkler Head Friction Loss. • See listing(s) approval agency for the latest approval details. • Friction loss data and specification of SuperFlex series include all end connection such as 1†NPT, 1†cut groove, and SLT. Specify end connection when ordering. 11 FLEXHEAD® FLEXHEAD® CEILING DETAIL SUSPENDED CEILING DETAIL MPO24BKT2 Bracket MPT24BKT1 Bracket *Allows for bracket installation without pre-installing the ceiling tile GYPSUM BOARD HARD CEILING DETAIL MPO24BKT2, ADO24BKT3 MPT24BKT1 Bracket & ADO16BKT3 Brackets Each FM approved and UL listed unit is ready to install, pressure- and leak-tested, and comes complete with a flexible stainless steel hose and mounting bracket with adjustable hub. FLEXHEAD® STANDARD HOSE 3" BEND RADIUS FLEXHEAD® STANDARD HOSE SHOWN PER UL GUIDELINES (2 BENDS SHOWN)* WITH 3 BENDS 1 2 * Notes: SuperFlex® has a 2" bend radius. For more information on SuperFlex® specification refer to page 10. 12 BUILDING CONNECTIONS THAT LAST FLEXHEAD® CEILING DETAIL REGULAR 1" HOSE MODEL REGULAR 1" HOSE MODEL ELBOW 1" HOSE MODEL STANDARD- 1 1/4" HOSE MODEL 20XXSF & 20XXT SERIES 20XXH SERIES 20XXE, 20XXHE & 20XXET SERIES 20XXF SERIES 1" NPT 1" NPT 1" 1" NPT THREAD 3 in CUT GROOVE 3 in 3 in NPT 3 in OR 1 ¼" CUT OPTION WITH GROOVE OPTION 20XXSF AVAILABLE L ±20mm L ±20mm L ±20mm L ±20mm 5.5" 1.5 in 5.0" 4.5" Ø 1.315 in 4.0" 1.5 in 4.50 in 3.5" "D" 2.25 in 3.0" SEE CHART 6.3 in 2.5" 2.0" 1.5" Ø 1.315 in Ø 1.315 in 1.0" ½" NPT OR 3/4"NPT FEMALE THREAD ½" NPT, 3/4" OR 1" NPT FEMALE THREAD Ø 1.315 in ½" NPT OR 3/4"NPT FEMALE THREAD MODEL # “Hose Assembly (L) Length Inches (mm)†“Drop “â€Dâ€â€ Size (Inches)†2024E/2024HE 24 (610) 2036E/2036HE 36 (914) 2048E/2048HE 48 (1219) 1.5, 3.0, & 4.0 2060E/2060HE 60 (1524) 2072E/2072HE 72 (1828) 2024ET 24 (610) 2036ET 36 (914) 2048ET 48 (1219) 5.71 2060ET 60 (1524) 2072ET 72 (1828) 13 FLEXHEAD® BRACKET SPECIFICATION SHEET MODEL MPO24BKT2 MODEL AD016BKT3, AD024BKT3, AD030BKT3, Multiport Design (For use with T-bar and Metal Stud Applications) & AD048BKT3 Adjustable Design (For use with T-bar, Metal Stud and Chicago Grid Applications): standard sizes are 16", 24", 30" and 48" long MODEL MPT24BKT1 Multi-Position Tall Bracket (For use with T-bar, Wood and Metal Studs): 24" standard size collapsible to 14.5" and 16" long. 24in [609 mm ] 16 in [ 406 mm ] 14.5 in [ 368.3 mm ] 14 BUILDING CONNECTIONS THAT LAST FLEXHEAD® COMMERCIAL PRODUCTS STANDARD FLEXHEAD® HOSE LENGTHS: 24", 36", 48", 60" AND 72" 24", 36", 48", 60", and 72" hose lengths, Rated working pressure 24", 36", 48", 60", and 72" hose lengths. Rated working pressure 175psi, optional 300psi. Standard 1" I.D., optional 11â„ 4" I.D. 175psi, optional 300psi. STRAIGHT MODEL ELBOW MODEL SUPERFLEX® HOSE LENGTHS: 36", 48", AND 72" MODEL MP024BKT2 MODELS AD016BKT3, AD024BKT3, 24" Multiport Bracket for T-bar Grid or Metal Stud applications. AD030BKT3 & ADO48BKT3 6" stable mounting bracket. 16", 24", 30", 48" Adjustable Bracket for T-bar Grid, Chicago Grid or Metal Stud applications. MODEL ADO24BKT3 WITH BKT-HTA MODEL MPT24BKT1 Hat Channel Bracket System for Metal Stud or Hat Channel applications. 24" Multi-Position Tall Bracket, collapses to 14 1/2" and 16". Installs in suspended ceilings without touching the ceiling tiles. MODEL UHO-3 MODEL SP06TZBKT2 MODEL 20XX-DPS-UHO-3 Designed for quick and easy installation. Ideal Armstrong® TechZone Ceiling Bracket for use Dry Pendent System for Freezer and for shell applications. Can be installed with with Armstrong TechZone Ceiling systems. Cold Storage applications 3/8" threaded rod up to 4' off structure and Available in 6" widths. with 1/2" threaded rod up to 6' off structure. 15 FLEXHEAD® FLEXHEAD® STANDARD SPECIFICATIONS DIVISION 21 MECHANICAL – SECTION 15300 FIRE PROTECTION PIPING FLEXIBLE SPRINKLER HOSE FITTINGS FOR FIRE PROTECTION SERVICE A. Manufacturer: FlexHead; Brand of Anvil International B. Contact: 160 Frenchtown Rd, North Kingstown RI 02852 ; Telephone: (800) 829-6975; Email: FlexHeadsales@anvilintl.com; website: www.flexhead.com & www.anvilintl.com 1. Substitutions: No substitutions allowed. C. Description: 1. Regulatory Requirements: Provide flexible stainless steel hose fittings that comply with the following requirements: a. In accordance with General Requirements contained in Division 1 of specification. b. In accordance with NFPA 13. D. Performance Criteria: Comply with the following to suit project requirements: 1. 1. FM 1637 Approval Standard for Flexible Sprinkler Hose with Threaded End Fittings. 2. 2. UL 2443 Standard for Flexible Sprinkler Hose with Fittings for Fire Protection Service 3. 3. ICC-ES AC-156 Acceptance Criteria for Seismic Qualification by Shake-Table Testing of Nonstructural Components and Systems E. Materials: FlexHead Commercial Sprinkler Connections 1. FlexHead flexible stainless steel hose assemblies: a. Straight Hose Assembly Lengths: {2ft length, Model #2024T, 2024SF} {3ft length, Model #2036T, 2036SF} {4ft length, Model #2048T, 2048SF} {5ft length, Model #2060T, 2060SF} {6ft length, Model #2072T, 2072SF}.} 1. {½ inch} {3/4 inch} outlet. 2. {175 psi} {300 psi} maximum rated pressure. 3. Fully welded non-mechanical fittings, braided, 100% leak-tested, with a minimum 1 inch true-bore internal corrugated hose diameter made of 100% 304 stainless steel braid, hose and end fittings. 1†NPT, 1†cut groove, or SLT end connection with 74FP SlideLOK®. b. Elbow Hose Assembly Lengths (For use in confined spaces): {2ft length, Model #2024E, 2024ET} {3ft length, Model #2036E, 2036ET} { 4ft length, Model #2048E, 2048ET} {5ft length, Model #2060E, 2060ET} { 6ft length, Model #2072E, 2072ET} 1. {½ inch} {3/4 inch} outlet. 2. {175 psi} {300psi} maximum rated pressure. 3. Fully welded non-mechanical fittings, braided, leak-tested with minimum 1 inch true-bore internal corrugated hose diameter made of 100% 304 stainless steel including end fittings. 2. FlexHead Ceiling Bracket: Direct attachment type having integrated ends positively attached to the ceiling using screws and attachment hub with set screw for attaching and adjusting flexible hose. 16 BUILDING CONNECTIONS THAT LAST APPLICABLE STANDARDS BUILDING CODES American Society of Civil Engineers (ASCE) -SEI/ASCE 7-05, Current data on building code requirements and product Section 13.5.6 Suspended Ceilings compliance may be obtained from the manufacturer’s tech- nical support specialists. Installation must comply with the ASTM INTERNATIONAL requirements of applicable local, state and national • ASTM C635 Standard Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in code jurisdictions. Panel Ceilings • ASTM C636 Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels COST • FM Global Technologies LLC (FM) - FM Class Number 1637 Approval Budget installed cost information may be obtained from the Standard for Flexible Sprinkler Hose with Threaded End Fittings manufacturer upon request. INTERNATIONAL CODE COUNCIL (ICC) • ICC International Building Code (IBC), 2006 MAINTENANCE - Section 803.9 Acoustical Ceiling Systems Contact the manufacturer for complete maintenance - Section 1613 Earthquake Loads information. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) • NFPA 13 Standard for the Installation of Sprinkler Systems • NFPA 13D Standard for the Installation of Sprinkler Systems in One- TECHNICAL SERVICES and Two-Family Dwellings and Manufactured Homes Design assistance and technical support are available upon • NFPA 13R Standard for the Installation of Sprinkler Systems in request from the manufacturer’s trained staff. Residential Occupancies up to and Including Four Stories in Height Underwriters Laboratories, Inc. (UL) - UL 2443 Standard for Flexible Sprinkler Hose with Fittings for Fire Protection Service FILING SYSTEMS • MANU-SPEC® APPROVALS Underwriters Laboratories, Inc. (UL) - UL Listed, VENF. • Additional product information is available from the EX5269, Flexible Sprinkler Hose Fitting manufacturer upon request PRECAUTIONS PHYSICAL/CHEMICAL PROPERTIES Consult the manufacturer’s installation instructions for Test reports are available to design professionals upon complete installation information. Failure to follow the cited request. instructions may cause personal injury. During maintenance or inspection of FlexHead product, the facility fire protection PREPARATORY WORK system must be inactive. Do not attempt relocation or Installation should only be performed by qualified and maintenance of FlexHead product while fire protections licensed technicians in the fire protection field. Consult NFPA, system is live. FM, UL and state and local guidelines prior to installation. DISCLAIMER METHODS • It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the Each FlexHead ceiling sprinkler connection includes a intended fluid media within the piping system and external environments. The effect of chemical composition, pH level, operating mounting bracket and a 1-piece, leak tested FlexHead temperature, chloride level, oxygen level, and flow sprinkler drop. rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life Attach the bracket to the t-bar ceiling grid; then attach will be acceptable for the intended service. the FlexHead sprinkler to the sub-main. Secure the sprinkler • Failure to follow these instructions could causeproduct failure, resulting in serious personal injury and/or property damage. to the bracket. Test installation of sprinkler system for any leaks per NFPA guidelines. 17 FLEXHEAD® BRANDS OF ANVIL INTERNATIONAL Anvil product lines include malleable and cast iron fittings, unions and Anvil-Strut products include a complete line of channel in stock lengths of 10 flanges; seamless and welded steel pipe nipples; steel pipe couplings; and 20 feet, with custom lengths available upon request. A variety of fittings and universal anvilets; forged steel fittings and unions; pipe hangers and accessories are also offered. All products can be ordered in an assortment of supports; threaded rod; and engineered hangers finishes and material choices including SupR-GreenTM, Zinc Trivalent Chromium, pre- galvanized, hot-dipped galvanized, electro-galvanized, aluminum, plain, and stainless steel. The SPF/Anvil product line includes a variety of internationally sourced Anvil EPS-Engineered Pipe Supports are products used to support piping products such as grooved couplings, fittings, cast iron, malleable iron systems under thermal, seismic, and other dynamic loading conditions. The and ductile iron threaded fittings, steel pipe nipples, as well as tee-lets. product line encompasses variable spring hangers, constant supports, sway struts and snubbers as well as standard and special design clamps. Anvil EPS brings the highest quality products and innovative engineering solutions to common and uncommon piping system problems. The Merit product line includes a variety of tee-lets and drop nipples for fire Catawissa hammer unions are offered in threaded ends and butt weld ends, and are protection applications. Most Merit products are UL/ ULC Listed, FM interchangeable with most leading union manufacturers. Fully traceable and available Approved, and rated from 175 to 300 psi. with complete mill certifications, Catawissa’s oilfield hammer union product line includes the standard ball-and-cone design plus our unique Figure 300 Flat Face design, where space and pipe line separation are a consideration. The AnvilPressâ„¢ Technology for Copper Systems and Stainless Steel Systems includes couplings, elbows, tees, adapters, fitting reducers, caps, unions, and flanges for mechanical copper systems. They provide an economical and reliable piping connection that can be used for commercial, industrial, and residential markets. Fittings are available in sizes 1/2" to 4". Copper fittings can be easily identified with a visual inspection of the patented green indicator band extruded at each joint. 18 BUILDING CONNECTIONS THAT LAST The Gruvlok product line consists of couplings for grooved and plain-end fittings, butterfly valves and check valves; flanges; pump protection components; pipe grooving tools; as well as copper and stainless steel system components. We invented the concept of Flexible Fire Protectionâ„¢. FlexHead systems The Afcon seismic bracing line includes UL listed and FM approved connect sprinkler heads to sub-mains at least four times faster than hard structural attachments for concrete, wood or steel structural members pipe. Delivers even greater savings in retrofits. All our flexible sprinkler like bar joist or I-beams, swivel connections that accept from 1" to 2" pipe and connections are UL Listed and/or FM Approved. schedule 40 pipe. Afcon’s seismic system attachments are engineered for up to 12" IPS steel pipe, copper tubing or plastic pipe. The SprinkFLEX® product line includes a variety of hoses and brackets JB Smith is the leading manufacturer of oil country tubular fittings, swages offering a cost effective solution for the installation of fire sprinkler systems and bull plugs – all meeting API specifications. Offering tubing nipples, casing which result in a quick and easy way to connect the sprinkler heads to the nipples as well as a full line of traditional line pipe and oil country threads in branch lines. All hoses and brackets are UL and/or FM Approved. every schedule, JB Smith is the resource for all your oilfield needs. North Alabama Pipe Steel pipe nipples and steel pipe couplings are manufactured in accordance Founded in 1983, NAP is a manufacturer of fabrication equipment, including with the ASTM A733 Standard Specification for Welded and Seamless automatic welders, plasma cut-off equipment, hole cutting equipment, make-on Carbon Steel and Stainless Steel Pipe Nipples. Steel pipe couplings are machines and pipe threaders. NAP, innovators of pipe fabrication equipment. manufactured in accordance with the ASTM A865 Standard Specification for Threaded Couplings, Steel, Black or Zinc-Coated (Galvanized) Welded or Seamless, for Use in Steel Pipe Joints. API couplings are manufactured in accordance with the API Specification for line pipe. 19 CUSTOMER SERVICE CENTERS UNITED STATES Corporate Headquarters TEL: 800-301-2701 FAX: 708-534-5441 Plants EMAIL: customerservice@anvilintl.com Exeter, NH Regional Distribution Centers CANADA Simcoe, ON, Canada TEL: 800-661-8998 North Kingstown, RI FAX: 519-426-5509 EMAIL: canadacs@anvilintl.com Somerset, NJ Columbia, PA LATIN AMERICA Johnstown, PA TEL: +1-800-885-3000 Tinley Park, IL Waynesboro, PA FAX: +1-708-534-5441 Greencastle, PA EMAIL: latinoamerica@anvilintl.com INTERNATIONAL TEL: +31-53-572-5570 EMAIL: internationalsales@anvilintl.com Henderson, TN REGIONAL Ontario, CA Guntersville, AL DISTRIBUTION Irving, TX CENTERS UNITED STATES ILLINOIS 7979 W. 183rd Street, Unit D Tinley Park, IL 60484 Houston, TX Orlando, FL TEXAS 1401 Valley View Lane, Suite 150 Irving, TX 75061 PENNSYLVANIA 800 Malleable Road Columbia, PA 17512 CALIFORNIA 551 North Loop Drive Ontario, CA 91761 FLORIDA 236 Outlook Point Drive, Suite 100 Orlando, FL 32809 CANADA ONTARIO 390 Second Avenue, P.O. Box 40 Simcoe Ontario, Canada N3Y 4K9 20 Exeter, NH Simcoe, ON, Canada North Kingstown, RI Somerset, NJ Columbia, PA Johnstown, PA Tinley Park, IL Waynesboro, PA Greencastle, PA Henderson, TN Ontario, CA Guntersville, AL Irving, TX Houston, TX Orlando, FL ANVIL MAINTAINS CONTRACTS WITH A CORE FLEET OF CARRIERS TO PROVIDE EFFICIENTLY CONSISTENT DELIVERY SERVICES TO OUR CLIENTS. www.anvilintl.com ©2019 Anvil International. Anvil, Gruvlok, Merit, SPF Anvil, SlideLOK, FlexHead, SuperFlex, Afcon, Seisbrace, ANV_BRO_FP_190625 Anvil-Strut are registered trademarks of Anvil International, LLC. All Rights Reserved. Pipe Hangers TOLCOâ„¢ Fig. 200 - “Trimline†Adjustable Band Hanger TOLCOâ„¢ Fig. 200F - “Trimline†Adjustable Band Hanger with Felt Lining for Copper Tubing TOLCOâ„¢ Fig. 200C - “Trimline†Adjustable Band Hanger with Plastic Coated TOLCOâ„¢ Fig. 200S - “Trimline†Adjustable Band Hanger with Removable Nut (For sizes 1†thru 2â€) Size Range: Fig. 200 - 1/2†(15mm) thru 8†(200mm) pipe A Overall Height Material: Steel, Pre-Galvanized B Function: For fire sprinkler and other general piping purposes. Knurled Center of pipe to top of knurled hanger rod nut. swivel nut design permits hanger adjustment after installation. D Top of pipe to bottom of hanger rod nut. Features: • 1/ Fig. 2†(15mm) thru 2†(50mm) sizes have flared edges for ease of installation on all pipe types and protects CPVC plastic pipe from 200-1/2& 200-3/4 abrasion. Captured knurled nut design (flared top) on 1†thru 2†sizes D keep nut from separating with hanger. Hanger is easily installed around pipe. • 1/2†(15mm), 3/4†(20mm), and 21/2†(65mm) thru 8†(200mm)) Spring B tension on nut holds it securely in hanger before installation. Knurled nut is easily removed. A • For 1/2†(15mm) and 3/4†(20mm) sizes with non-captured knurl nuts order Fig. 200S Fig. Approvals: Underwriters Laboratories listed (1/2†(15mm) thru 8†(200mm)) 200-21/2to 200-8 in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Fig. Factory Mutual Engineering Approved (FM) (3/4†(20mm) thru 8†(200mm)). 200-1 to Conforms to Federal Specifications WW-H-171E & A-A-1192A, Type 10 200-2 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Part number and pipe size Pipe Hangers ** Note: For metric hanger rod sizes add the metric rod size to the figure number. Example: 200M8-11/2 or 200M10-11/2 Fig. 200C Fig. 200F Fig. 200 Fig. 200 & Fig. 200S 200C-11/2shown 200F-11/2shown shown with captured nut shown with 1†thru 2†sizes only non-captured nut Pipe Size Rod Size AB D Max. Rec. Load Approx. Wt./100 Part No.** in. (mm) in. mm** in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 200-1/2 1/2" (15) 3/8"-16 M8 or M10 31/8" (79.4) 25/8" (66.7) 111/32" (34.1) 400 (1.78) 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 M8 or M10 31/8" (79.4) 21/2" (63.5) 11/16" (27.0) 400 (1.78) 11 (5.0) 200-1 1" (25) 3/8"-16 M8 or M10 33/8" (85.7) 25/8" (66.7) 11/8" (28.6) 400 (1.78) 12 (5.5) 200-11/4 11/4" (32) 3/8"-16 M8 or M10 33/4" (94.0) 27/8" (73.0) 15/32" (29.3) 400 (1.78) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 M8 or M10 37/8" (98.4) 27/8" (73.0) 13/16" (30.2) 400 (1.78) 14 (6.4) 200-2 2" (50) 3/8"-16 M8 or M10 41/2" (114.3) 3" (76.3) 13/16" (30.2) 400 (1.78) 15 (6.9) 200-21/2 21/2" (65) 3/8"-16 M10 55/8" (142.9) 41/8" (104.7) 17/16" (36.5) 600 (2.67) 27 (12.3) 200-3 3" (75) 3/8"-16 M10 57/8" (149.1) 4" (101.6) 11/4" (31.7) 600 (2.67) 29 (13.3) 200-31/2 31/2" (90) 3/8"-16 M10 73/8" (187.3) 51/4" (133.3) 23/16" (55.6) 600 (2.67) 34 (15.6) 200-4 4" (100) 3/8"-16 M10 73/8" (187.3) 5" (127.0) 13/8" (34.9) 1000 (4.45) 35 (16.0) 200-5 5" (125) 1/2"-13 M12 91/8" (231.8) 61/4" (158.7) 311/32" (84.9) 1250 (5.56) 66 (30.2) 200-6 6" (150) 1/2"-13 M12 101/8" (257.2) 63/4" (171.4) 27/32" (56.3) 1250 (5.56) 73 (33.4) 200-8 8" (200) 1/2"-13 M12 131/8" (333.4) 83/4" (222.2) 37/32" (81.7) 1250 (5.56) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 23 Eaton Pipe Hangers TOLCOâ„¢ Fig. 1CBS - Clevis Bolt Spacer OPM Size Range: Size 1" (25mm) thru 20" (500mm) clevis hanger Material: Steel Function: Used as a spacer at a seismic brace location to keep clevis hanger from collapsing during seismic event. Pipe Size Approx. Wt./100 Approvals: Included in our Seismic Engineering Guidelines Part No. in. (mm) lbs. (kg) approved by the State of California Office of Statewide Health 1CBS-1 1†(25) 3.2 (1.4) Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer 1CBS-11/4 11/4†(32) 4.1 (1.8) to our Seismic Engineering Guidelines OPM-0052-13, for 21â„2†- 8†1CBS-11/2 11/2†(40) 4.8 (2.2) (B3100) only 1CBS-2 2†(50) 9.4 (4.2) Installation Note: Fig. 1CBS fits easily over the cross bolt 1CBS-21/2 21/2†(65) 11.4 (5.2) and attaches by pinching tabs down. 1CBS-3 3†(75) 13.9 (6.8) Finish: Pre-Galvanized. Contact customer service for alternative 1CBS-31/2 31/2†(90) 16.0 (7.2) finishes and materials. 1CBS-4 4†(100) 18.0 (8.1) Order By: Figure number and finish. 1CBS-5 5†(125) 27.3 (12.4) 1CBS-6 6†(150) 32.5 (14.7) 1CBS-8 8†(200) 42.5 (19.2) 1CBS-10 10†(250) 72.7 (32.9) 1CBS-12 12†(300) 86.3 (39.1) 1CBS-14 14†(350) 157.6 (71.5) 1CBS-16 16†(400) 183.7 (83.3) 1CBS-18 18†(450) 224.6 (101.9) 1CBS-20 20†(500) 254.0 (115.2) Pipe Hangers TOLCOâ„¢ Fig. 25 - Surge Restrainer Size Range: — One size fits 3â„4" (20mm) thru 2" (40mm) pipe. Material: — Pre-Galvanized Steel Function: — Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2016 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: — Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3â„4" (20mm) thru 2" (40mm). Patent #5,344,108 Approx. Wt./100 Part No. lbs. (kg) 25 4.8 (2.2) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton Revised 8/8/2014 22 B-Line series Fire Protection Solutions Fire Sprinkler Pipe Schedule 10 and Schedule 40 Submittal Data Sheet FM Approved and Fully Listed Sprinkler Pipe Finishes and Coatings Wheatland Tube’s Schedule 10 and Schedule All Wheatland black steel fire sprinkler pipe 40 steel fire sprinkler pipe is FM Approved receives a proprietary mill coating to ensure a and UL® and C-UL Listed. clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This Approvals and Specifications coating allows the pipe to be easily painted, Schedule 10 and Schedule 40 meet or exceed without special preparation. Schedule 10 and the following standards: Schedule 40 can be ordered in black or hot-dip galvanized, to meet FM / UL requirements for dry • ASTM A135, Type E, Grade A systems that meet the zinc coating specifications (Schedule 10, 1–8 NPS) of ASTM A795 or A53. • ASTM A795, Type E, Grade A (Schedule 40, 1–2 NPS) Product Marking • ASTM A53, Type E, Grade B Each length of Wheatland fire sprinkler (Schedule 40, 2–8 NPS) pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size • ASTM A53, Type F, Grade A and length. Bar coding is acceptable as a (Schedule 40, 1–4 NPS) supplementary identification method. • NFPA® 13 and NFPA 14 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. SUBMITTAL INFORMATION PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: BLACK HOT-DIP GALVANIZED 700 South Dock Street info@wheatland.com Sharon, PA 16146 wheatland.com P 800.257.8182 Follow us on Twitter: F 724.346.7260 @WheatlandTube Fire Sprinkler Pipe Schedule 10 and Schedule 40 Submittal Data Sheet SCHEDULE 10 WEIGHTS AND DIMENSIONS WT. / FT. WT. / LIFT WT. / LIFT WT. / LIFT NPS NOMINAL OD NOMINAL ID NOMINAL WALL WT. / FT. H O FILLED PCS. / LIFT 21' 24' 25' UL 2 in. mm in. mm in. mm lbs. lbs. lbs. lbs. lbs. CRR* 1 1.315 33.4 1.097 27.9 0.109 2.77 1.405 1.814 70 2065 2360 2459 11.4 1 1/4 1.660 42.2 1.442 36.6 0.109 2.77 1.807 2.514 61 2315 2645 2756 7.3 1 1/2 1.900 48.3 1.682 42.7 0.109 2.77 2.087 3.049 61 2673 3055 3183 5.8 2 2.375 60.3 2.157 54.8 0.109 2.77 2.640 4.222 37 2051 2344 2442 4.7 2 1/2 2.875 73.0 2.635 66.9 0.120 3.05 3.354 5.895 30 2226 2544 2651 3.5 3 3.500 88.9 3.260 82.8 0.120 3.05 4.336 7.949 19 1730 1977 2060 2.6 4 4.500 114.3 4.260 108.2 0.120 3.05 5.619 11.789 19 2242 2562 2669 1.6 5 5.563 141.3 5.295 134.5 0.134 3.40 7.780 17.309 13 2124 2427 2529 1.5 6 6.625 168.3 6.357 161.5 0.134 3.40 9.298 23.038 10 1953 2232 2325 1.0 8 8.625 219.1 8.249 209.5 0.188 4.78 16.960 40.086 7 2493 2849 2968 2.1 SCHEDULE 40 WEIGHTS AND DIMENSIONS WT. / FT. WT. / LIFT WT. / LIFT WT. / LIFT NPS NOMINAL OD NOMINAL ID NOMINAL WALL WT. / FT. H O FILLED PCS. / LIFT 21' 24' 25' UL 2 in. mm in. mm in. mm lbs. lbs. lbs. lbs. lbs. CRR* 1 1.315 33.4 1.049 26.6 0.133 3.38 1.68 2.055 70 2470 2822 2940 1.000 1 1/4 1.660 42.2 1.380 35.1 0.140 3.56 2.27 2.922 51 2431 2778 2894 1.000 1 1/2 1.900 48.3 1.610 40.9 0.145 3.68 2.72 3.602 44 2513 2872 2992 1.000 2 2.375 60.3 2.067 52.5 0.154 3.91 3.66 5.109 24 1845 2108 2196 1.000 2 1/2 2.875 73.0 2.469 62.7 0.203 5.16 5.80 7.871 20 2436 2784 2900 1.000 3 3.500 88.9 3.068 77.9 0.216 5.49 7.58 10.783 13 2069 2365 2464 1.000 3 1/2 4.000 101.6 3.548 90.1 0.226 5.74 9.12 13.400 10 1915 2189 2280 1.000 4 4.500 114.3 4.026 102.3 0.237 6.02 10.80 16.311 10 2268 2592 2700 1.000 5 5.563 141.3 5.047 158.2 0.258 6.55 14.63 23.262 7 2151 2458 2560 1.000 6 6.625 168.3 6.065 154.1 0.280 7.11 18.99 31.498 5 1994 2279 2374 1.000 8** 8.625 219.1 7.981 202.7 0.322 8.18 28.58 50.240 5 3001 3430 3573 1.000 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). ** 8 NPS Schedule 40 is FM Approved but not UL Listed. WFS-081619 700 South Dock Street info@wheatland.com Sharon, PA 16146 wheatland.com P 800.257.8182 Follow us on Twitter: F 724.346.7260 @WheatlandTube DUCTILE IRON THREADED FITTINGS FIG. 3201 90Ëš Elbow A A For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3201 - 90° ELBOW MATERIAL SPECIFICATIONS Maximum Nominal Size Working Pressure Dimension A Approx. Wt. Each Dimensions: ASME B16.3 s In. (mm) PSI (kPa) In. (mm) Lbs. (kg) Material: ASTM A536 Grade 65-45-12 1 500 1.50 0.62 Finish: Black 20 3450 38.10 0.28 11â„4 500 1.75 0.90 Threads: NPT per ASME B1.20.1 32 3450 44.45 0.41 Agency Approvals: All ductile iron threaded fittings are 11â„ 2 500 1.94 1.20 UL/ULC Listed and FM Approved. 40 3450 49.276 0.54 2 500 2.25 1.85 50 3450 57.15 0.84 NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or leakage. Ductile iron fittings should be tightened approximately three turns beyond contact your local Anvil Representative. hand tight, but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: q Approved Address: q Approved as noted Contractor: q Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS FIG. 3202 45Ëš Elbow A A For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3202 - 45° ELBOW MATERIAL SPECIFICATIONS Maximum Nominal Size Working Pressure Dimension A Approx. Wt. Each Dimensions: ASME B16.3 s In. (mm) PSI (kPa) In. (mm) Lbs. (kg) Material: ASTM A536 Grade 65-45-12 1 500 1.12 0.46 Finish: Black 25 3450 28.44 0.21 11â„4 500 1.29 0.73 Threads: NPT per ASME B1.20.1 32 3450 32.76 0.33 Agency Approvals: All ductile iron threaded fittings are 11â„ 2 500 1.43 0.92 UL/ULC Listed and FM Approved. 40 3450 36.32 0.42 2 500 1.68 1.50 50 3450 42.67 0.68 NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or leakage. Ductile iron fittings should be tightened approximately three turns beyond contact your local Anvil Representative. hand tight, but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: q Approved Address: q Approved as noted Contractor: q Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS FIG. 3201R Reducing 90Ëš Elbow B 2 A 1 For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or 1 x 2 contact an Anvil® Sales Representative. FIGURE 3201R - REDUCING 90° ELBOW MATERIAL SPECIFICATIONS Nominal Size Max. Working Dimensions Approx. 1 x 2 Pressures A B Wt. Each Dimensions: ASME B16.3 In. (mm) PSI (kPa) In. (mm) In. (mm) Lbs. (kg) Material: ASTM A536 Grade 65-45-12 1 x 1â„ 2 500 1.26 1.36 0.44 Finish: Black 25 x 15 3450 32.00 34.54 0.20 1 x 3â„ Threads: NPT per ASME B1.20.1 4 500 1.37 1.45 0.52 25 x 20 3450 34.79 36.83 0.24 Agency Approvals: All ductile iron threaded fittings are 11â„ 1 4 x â„2 500 1.34 1.53 0.64 UL/ULC Listed and FM Approved. 32 x 15 34550 34.03 38.86 0.29 11â„ 3 4 x â„4 500 1.45 1.62 0.72 32 x 20 3450 36.83 41.14 0.33 NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause 11â„ 4 x 1 500 1.58 1.67 0.75 leakage. Ductile iron fittings should be tightened approximately three turns beyond 32 x 25 3450 40.13 42.41 0.34 hand tight, but no more than four turns. 11â„ 2 x 1 500 1.65 1.80 0.92 40 x 25 3450 41.91 45.72 0.42 11â„ 1 2 x 1â„4 500 1.82 1.88 1.08 40 x 32 3450 46.22 47.75 0.49 2 x 1â„ 2 500 1.49 1.88 1.08 50 x 15 3450 37.84 47.75 0.49 2 x 3â„ 4 500 1.60 1.97 1.24 50 x 20 3450 40.64 50.03 0.56 2 x 1 500 1.73 2.02 1.40 50 x 25 3450 43.94 51.30 0.64 2 x 11â„ 4 500 1.90 2.10 1.52 50 x 32 3450 48.26 53.34 0.70 2 x 11â„ 2 500 2.02 2.16 1.65 50 x 40 3450 51.30 54.86 0.75 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project: q Approved Address: q Approved as noted Contractor: q Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS FIG. 3205R Reducing Tee C 2 B 3 A 1 For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or 1 x 2 x 3 contact an Anvil® Sales Representative. FIGURE 3205R - REDUCING TEE MATERIAL SPECIFICATIONS Nominal Size Max. Dimensions Working Approx. Dimensions: ASME B16.3 Wt. Each 1 x 2 x 3 Pressures A B C Material: ASTM A536 Grade 65-45-12 In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) Finish: Black 1 x 1â„ 2 x 1 500 1.50 1.36 1.50 0.64 Threads: NPT per ASME B1.20.1 25 x 15 x 25 3450 38.10 34.54 38.10 0.29 1 x 3â„ 4 x 1 500 1.50 1.45 1.50 0.73 Agency Approvals: All ductile iron threaded fittings are 25 x 20 x 25 3450 38.10 36.83 38.10 0.33 UL/ULC Listed and FM Approved. 1 x 1 x 1â„ 2 500 1.26 1.26 1.36 0.71 25 x 25 x 15 3450 32.00 32.00 34.54 0.32 1 x 1 x 3â„4 500 1.37 1.37 1.45 0.76 NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause 25 x 25 x 20 3450 34.80 34.80 36.83 0.34 leakage. Ductile iron fittings should be tightened approximately three turns beyond 1 x 1 x 11â„ 4* 500 1.67 1.67 1.58 0.98 hand tight, but no more than four turns. 25 x 25 x 32 3450 42.41 42.41 40.13 0.44 1 x 1 x 11â„ 2* 500 1.80 1.80 1.65 1.16 25 x 25 x 40 3450 45.72 45.72 41.91 0.53 FIGURE 3205R - REDUCING TEE 11â„ 1 4 x 1 x â„2* 500 1.34 1.26 1.53 0.82 32 x 25 x 15 3450 34.04 32.00 38.86 0.37 Nominal Size Max. Dimensions Approx. 11â„4 x 1 x 3â„4 500 1.45 1.37 1.62 0.90 Working Wt. Each 32 x 25 x 20 3450 36.83 34.80 41.15 0.41 1 x 2 x 3 Pressures A B C 11â„ 4 x 1 x 1 500 1.58 1.50 1.67 1.00 In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 32 x 25 x 25 3450 40.13 38.10 42.42 0.45 1 1 11â„ 1 3 1â„4 x 1 x 1â„4 500 1.75 1.67 1.75 1.08 4 x 1â„4 x â„4 500 1.45 1.45 1.62 0.92 32 x 25 x 32 3450 44.45 42.42 44.45 0.49 32 x 32 x 20 3450 36.83 36.83 41.15 0.42 1 1 11â„ 1 1â„4 x 1 x 1â„2 500 1.88 1.80 1.82 1.42 4 x 1â„4 x 1 500 1.58 1.58 1.67 0.95 32 x 25 x 40 3450 47.75 45.72 46.22 0.64 32 x 32 x 25 3450 40.13 40.13 42.42 0.43 11â„ 1 1 11â„4 x 11â„4 x 11â„2* 500 1.88 1.88 1.82 1.45 4 x 1â„4 x â„2 500 1.34 1.34 1.53 0.86 32 x 32 x 15 3450 34.04 34.04 38.86 0.39 32 x 32 x 40 3450 47.75 47.75 46.22 0.66 s Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as "Bull Head Tee". PROJECT INFORMATION APPROVAL STAMP Project: q Approved Address: q Approved as noted Contractor: q Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS FIG. 3205R Reducing Tee C 2 B 3 A 1 1 x 2 x 3 FIGURE 3205R - REDUCING TEE FIGURE 3205R - REDUCING TEE Nominal Size Max. Dimensions Nominal Size Max. Dimensions Approx. Approx. Working Working Wt. Each Wt. Each 1 x 2 x 3 Pressures A B C 1 x 2 x 3 Pressures A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1 1 11â„ 1 1â„4 x 1â„4 x 2* 500 2.10 2.10 1.90 1.75 2 x 1â„2 x 2* 500 2.16 2.16 2.02 1.98 32 x 32 x 50 3450 53.34 53.34 48.26 0.79 40 x 40 x 50 3450 54.86 54.86 51.30 0.90 11â„ 1 2 x 1 x 2 500 2.25 2.02 2.25 2.15 2 x 1 x â„2 500 1.41 1.34 1.66 0.95 40 x 25 x 15 3450 35.81 34.04 42.16 0.43 50 x 25 x 50 3450 57.15 51.31 57.15 0.98 1 3 2 x 11â„ 1â„2 x 1 x â„4 500 1.52 1.37 1.75 1.14 4 x 2 500 2.25 2.10 2.25 2.30 40 x 25 x 20 3450 38.61 34.80 44.45 0.52 50 x 32 x 50 3450 57.15 53.34 57.15 1.04 1 2 x 11â„ 1 1â„2 x 1 x 1 500 1.65 1.50 1.80 1.17 2 x â„2 500 1.49 1.41 1.88 1.50 40 x 25 x 25 3450 41.91 38.10 45.72 0.53 50 x 40 x 15 3450 37.85 35.81 47.75 0.68 1 1 2 x 11â„ 3 1â„2 x 1 x 1â„4 500 1.82 1.67 1.88 1.34 2 x â„4 500 1.60 1.52 1.97 1.62 40 x 25 x 32 3450 46.23 42.42 47.75 0.61 50 x 40 x 20 3450 40.64 38.61 50.04 0.73 1 1 2 x 11â„ 1â„2 x 1 x 1â„2 500 1.94 1.80 1.94 1.45 2 x 1 500 1.73 1.65 2.02 1.64 40 x 25 x 40 3450 49.28 45.72 49.28 0.66 50 x 40 x 25 3450 43.94 41.91 51.31 0.74 1 1 1 2 x 11â„ 1 1â„2 x1â„4 x â„2 500 1.41 1.34 1.66 1.05 2 x 1â„4 500 1.90 1.82 2.10 1.80 40 x 32 x 15 3450 35.81 34.04 42.16 0.48 50 x 40 x 32 3450 48.26 46.23 53.34 0.82 1 1 3 2 x 11â„ 1 1â„2 x1â„4 x â„4 500 1.52 1.45 1.75 1.15 2 x 1â„2 500 2.02 1.94 2.16 2.00 40 x 32 x 20 3450 38.61 36.83 44.45 0.5 50 x 40 x 40 3450 51.31 49.28 54.86 0.91 1 1 2 x 11â„ 1â„2 x 1â„4 x 1 500 1.65 1.58 1.80 1.25 2 x 2 500 2.25 2.16 2.25 2.35 40 x 32 x 25 3450 41.91 40.13 45.72 0.57 50 x 40 x 50 3450 57.15 54.86 57.15 1.07 1 1 2 x 2 x 1â„ 1â„2 x 1â„4 x 2* 500 2.16 2.10 2.02 1.90 2 500 1.49 1.49 1.88 1.60 40 x 32 x 50 3450 54.86 53.34 51.30 0.86 50 x 50 x 15 3450 37.85 37.85 47.75 0.73 1 1 1 2 x 2 x 3â„ 1â„2 x 1â„2 x â„2 500 1.41 1.41 1.16 1.15 4 500 1.60 1.60 1.97 1.68 40 x 40 x 15 3450 35.81 35.81 29.46 0.52 50 x 50 x 20 3450 40.64 40.64 50.04 0.76 11â„ 1 3 2 x 2 x 1 500 1.73 1.73 2.02 1.85 2 x 1â„2 x â„4 500 1.52 1.52 1.75 1.24 40 x 40 x 20 3450 38.61 38.61 44.45 0.56 50 x 50 x 25 3450 43.94 43.94 51.31 0.84 1 1 2 x 2 x 11â„ 1â„2 x 1â„2 x 1 500 1.65 1.65 1.80 1.30 4 500 1.90 1.90 2.10 2.04 40 x 40 x 25 3450 41.91 41.91 45.72 0.59 50 x 50 x 32 3450 44.45 42.42 44.45 0.93 1 1 1 2 x 2 x 11â„ 1â„2 x 1â„2 x 1â„4 500 1.82 1.82 1.88 1.48 2 500 2.02 2.02 2.16 2.18 40 x 40 x 32 3450 46.23 46.23 47.75 0.67 50 x 50 x 40 3450 44.45 42.42 44.45 0.99 s Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as "Bull Head Tee". SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS FIG. 3205 Straight Tee A For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A A FIGURE 3205 - STRAIGHT TEE MATERIAL SPECIFICATIONS Maximum Nominal Size Working Pressure Dimension A Approx. Wt. Each Dimensions: ASME B16.3 s In. (mm) PSI (kPa) In. (mm) Lbs. (kg) Material: ASTM A536 Grade 65-45-12 1 500 1.50 0.85 Finish: Black 25 3450 38.10 0.39 11â„4 500 1.75 1.22 Threads: NPT per ASME B1.20.1 32 3450 44.45 0.55 Agency Approvals: All ductile iron threaded fittings are 11â„ 2 500 1.94 1.55 UL/ULC Listed and FM Approved. 40 3450 49.27 0.70 2 500 2.25 2.45 50 3450 57.15 1.11 NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or leakage. Ductile iron fittings should be tightened approximately three turns beyond contact your local Anvil Representative. hand tight, but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: q Approved Address: q Approved as noted Contractor: q Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS FIG. 3221 Coupling A For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3221 - COUPLING MATERIAL SPECIFICATIONS Maximum Nominal Size Working Pressure Dimension A Approx. Wt. Each Dimensions: ASME B16.3 s In. (mm) PSI (kPa) In. (mm) Lbs. (kg) Material: ASTM A536 Grade 65-45-12 1 500 1.67 0.40 Finish: Black 25 3450 42.42 0.18 11â„4 500 1.93 0.57 Threads: NPT per ASME B1.20.1 32 3450 49.02 0.26 Agency Approvals: All ductile iron threaded fittings are 11â„ 2 500 2.15 0.75 UL/ULC Listed and FM Approved. 40 3450 54.61 0.34 2 500 2.53 1.15 50 3450 64.26 0.52 NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or leakage. Ductile iron fittings should be tightened approximately three turns beyond contact your local Anvil Representative. hand tight, but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: q Approved Address: q Approved as noted Contractor: q Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS FIG. 3221R Reducing Coupling A For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3221R - REDUCING COUPLING MATERIAL SPECIFICATIONS Maximum Nominal Size Working Pressure Dimension A Approx. Wt. Each Dimensions: ASME B16.3 s In. (mm) PSI (kPa) In. (mm) Lbs. (kg) Material: ASTM A536 Grade 65-45-12 1 x 1â„ 2 500 1.69 0.39 Finish: Black 25 x 15 3450 42.92 0.18 1 x 3â„4 500 1.69 0.53 Threads: NPT per ASME B1.20.1 25 x 20 3450 42.92 0.24 Agency Approvals: All ductile iron threaded fittings are 11â„ 3 4 x â„4 500 2.06 0.64 UL/ULC Listed and FM Approved. 32 x 20 3450 52.32 0.29 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. contact your local Anvil Representative. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: q Approved Address: q Approved as noted Contractor: q Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-5.19 DUCTILE IRON THREADED FITTINGS C FIG. 3283 F B Bushings A M Inside Head C C F B F B A A For Listings/Approval Details and Limitations, M M visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. Inside Head Outside Head FIGURE 3283 - BUSHINGS MATERIAL SPECIFICATIONS Nominal SizeC Max. Working Dimensions Approx. Male (M) x Female (F)F Pressure A B C Style Wt. Each Dimensions: ASME B16.14 s B In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) Material: ASTM A536 Grade 65-45-12 A 1 x 1â„ M 2 500 0.75 0.25 1.42 Outside 0.22 Finish: Black 25 x 15 3450 19.05 6.35 36.06 0.10 1 x 3â„ Threads: NPT per ASME B1.20.1 Outside Head4 500 0.75 0.25 1.42 Outside 0.17 25 x 20 3450 19.05 6.35 36.06 0.08 Agency Approvals: All ductile iron threaded fittings are 11â„ 4 x 1 500 0.80 0.28 1.76 Outside 0.28 UL/ULC Listed and FM Approved. 32 x 25 3450 20.32 7.11 44.70 0.13 11â„ 2 x 1 500 0.83 0.31 2.00 Outside 0.45 40 x 25 3450 21.08 7.874 50.80 0.20 NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause 11â„ 1 2 x 1â„4 500 0.83 0.31 2.00 Outside 0.30 leakage. Ductile iron fittings should be tightened approximately three turns beyond 40 x 32 3450 21.08 7.874 50.80 0.14 hand tight, but no more than four turns. 2 x 1 500 0.88 0.41 1.95 Inside 0.67 50 x 25 3450 22.35 10.414 49.53 0.30 2 x 11â„ 4 500 0.88 0.34 2.48 Outside 0.73 50 x 32 3450 22.35 8.636 62.99 0.33 2 x 11â„ 2 500 0.88 0.34 2.48 Outside 0.61 50 x 40 3450 22.35 8.636 62.99 0.28 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project: q Approved Address: q Approved as noted Contractor: q Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS FIG. 3224 Cap A For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3224 - CAP MATERIAL SPECIFICATIONS Maximum Nominal Size Working Pressure Dimension A Approx. Wt. Each Dimensions: ASME B16.3 s In. (mm) PSI (kPa) In. (mm) Lbs. (kg) Material: ASTM A536 Grade 65-45-12 1 500 1.16 0.32 Finish: Black 25 3450 29.46 0.15 11â„4 500 1.28 0.43 Threads: NPT per ASME B1.20.1 32 3450 32.51 0.20 Agency Approvals: All ductile iron threaded fittings are 11â„ 2 500 1.33 0.60 UL/ULC Listed and FM Approved. 40 3450 33.78 0.27 2 500 1.45 0.91 50 3450 36.83 0.41 NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or leakage. Ductile iron fittings should be tightened approximately three turns beyond contact your local Anvil Representative. hand tight, but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: q Approved Address: q Approved as noted Contractor: q Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS FIG. 3388 Cored Plug A For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3388 - CORED PLUG MATERIAL SPECIFICATIONS Maximum Nominal Size Working Pressure Dimension A Approx. Wt. Each Dimensions: ASME B16.14 s In. (mm) PSI (kPa) In. (mm) Lbs. (kg) Material: ASTM A536 Grade 65-45-12 1â„ 2* 500 0.94 0.10 Finish: Black 15 3450 23.87 0.05 3â„4 500 1.07 0.17 Threads: NPT per ASME B1.20.1 20 3450 27.17 0.08 Agency Approvals: All ductile iron threaded fittings are 1 500 1.25 0.28 UL/ULC Listed and FM Approved. 25 3450 31.75 0.13 11â„ 4 500 1.36 0.44 s Pressure - Temperature Ratings in accordance with ASME B16.3 Class 150 32 3450 34.54 0.20 11â„ 2 500 1.45 0.62 NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. 40 3450 36.83 0.28 Therefore, over tightening can cause damage to pipe threads which may cause 2 500 1.56 0.91 leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. 50 3450 39.62 0.41 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as Solid Plug. PROJECT INFORMATION APPROVAL STAMP Project: q Approved Address: q Approved as noted Contractor: q Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-5.16 Permit #: 6703 Permit Date: 09/08/25 Permit Type: FIRE SPRINKLER Project Name: CASCADE VALLEY HOSP CT SCANNER Applicant Name: Columbia Fire LLC Applicant Address: 111 S Findlay St Applicant, City, State, Seattle Zip: Contact: James Ku Phone: 2062328569 Email: james.ku@columbiafire.net Scope of Work: MODIFY THE EXISTING FIRE SPRINKLER SYSTEM TO ACCOMMODATE THE NEW WALL. Valuation: 3552.00 Square Feet: 488 Number of Stories: 1 Construction Type: lA Occupancy Group: I-2; Institutional ID Code: Permit Issued: Permit Expires: Form Permit Type: FIRE SPRINKLER Status: VOID/WITHDRAWN Assigned To: Hannah Hardwick Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 330 S STILLAGUAMISH PUBLIC HOSPITAL 651 Medical & Other 31051100102900 AVE DISTRICT #3 Health Services Plan Reviews Date Review Type Description Assigned To Review Status No Comment 09/08/2025 FIRE SPRINKLER BUILDING Received No Comment 09/08/2025 FIRE SPRINKLER FIRE Received Fees Fee Description Notes Amount Enter 1 if permit is for: fire alarm, or fire Web Only - Fire System Plan Review $200.00 sprinkler Credit Card Service $6.00 Total $206.00 Attached Letters Date Letter Description 09/08/2025 Web Form - Building Application Payments Date Paid By Description Payment Type Accepted By Amount 09/08/2025 Mike Moffett 242376134 Hannah Hardwick $6.00 XBP Conf: 09/08/2025 $200.00 242376134 Outstanding Balance $0.00 Uploaded Files Date File Name 09/25/2025 28446437-Permit Withdrawal Request.pdf 09/08/2025 5ee8c7898288271d709db935ad42dd1a_12645013-fire_sprinkler.pdf 09/08/2025 54b827e1a4c1d96a676a5281121fe26d_cascade_valley_hosp_ct_scanner_-_material_submittal.pdf 09/08/2025 5c9d363959201b861fa0ff376f20bbf3_stamped_cascade_valley_hosp_ct_scanner_-_fp_24x36.pdf From: Luke Thompson To: Hannah Hardwick Cc: LaNay Hendrick Subject: RE: Permit #6703 - Cascade Valley Hospital Fire Protection Date: Thursday, September 25, 2025 8:54:35 AM Attachments: image004.png image005.png image006.png image007.png image008.png image009.png image010.png image011.png This message is from an External Sender This message came from outside the City of Arlington Good morning Hannah, It has been determined that the work associated with this permit was not required. Could you please proceed with cancelling the permit application so we can formally close out this item. Thank you, Luke Thompson Project Manager 111 Findlay St, Seattle, WA 98108 M: 206.519.8676 | O: 206.232.8569 www.columbiafire.net From: Hannah Hardwick <hhardwick@arlingtonwa.gov> Sent: Tuesday, September 23, 2025 9:35 AM To: Luke Thompson <Luke.Thompson@columbiafire.net> Cc: LaNay Hendrick <lhendrick@arlingtonwa.gov> Subject: RE: Permit #6703 - Cascade Valley Hospital Fire Protection CAUTION: This email originated from an untrusted source. Do not click links or open attachments unless you recognize the sender and know the contents are safe. Hello Luke, We do not have an expedited review process. Reviews may take less time depending on schedule and workload, but our Building Official is the reviewer and the inspector. Sincerely, Hannah Hardwick Community & Economic Development, Fire Permit Technician II 18204 59th Ave NE, Arlington, WA 98223 O: 360.403.3549 hhardwick@arlingtonwa.gov | www.arlingtonwa.gov Note: Emails and attachments sent to and from the City of Arlington are public records and may be subject to disclosure pursuant to the Public Records Act. From: Luke Thompson <Luke.Thompson@columbiafire.net> Sent: Tuesday, September 23, 2025 9:28 AM To: Hannah Hardwick <hhardwick@arlingtonwa.gov> Cc: LaNay Hendrick <lhendrick@arlingtonwa.gov> Subject: Re: Permit #6703 - Cascade Valley Hospital Fire Protection This message is from an External Sender This message came from outside the City of Arlington Hello Hannah, Thank you for your response. I understand that permit reviews typically take 4–6 weeks and that over-the-counter options are not available for this type of application. Given the time-sensitive nature of our project, I wanted to ask if there’s any possibility of expediting the review process—perhaps by paying an additional fee or through a priority review option. If such a pathway exists, we’d be very interested in pursuing it to help meet our project’s closeout deadline. I appreciate your time and any guidance you can provide. Best regards Luke Thompson Project Manager 111 Findlay St, Seattle, WA 98108 M: 206.519.8676 | O: 206.232.8569 www.columbiafire.net From: Hannah Hardwick <hhardwick@arlingtonwa.gov> Sent: Tuesday, September 23, 2025 9:21 AM To: Luke Thompson <Luke.Thompson@columbiafire.net> Cc: LaNay Hendrick <lhendrick@arlingtonwa.gov> Subject: RE: Permit #6703 - Cascade Valley Hospital Fire Protection CAUTION: This email originated from an untrusted source. Do not click links or open attachments unless you recognize the sender and know the contents are safe. Hello, The permit application is under review. Reviews typically take about 4-6 weeks to complete depending on the reviewers availability and workloads. Sincerely, Hannah Hardwick Community & Economic Development, Fire Permit Technician II 18204 59th Ave NE, Arlington, WA 98223 O: 360.403.3549 hhardwick@arlingtonwa.gov | www.arlingtonwa.gov Note: Emails and attachments sent to and from the City of Arlington are public records and may be subject to disclosure pursuant to the Public Records Act. From: Luke Thompson <Luke.Thompson@columbiafire.net> Sent: Tuesday, September 23, 2025 8:48 AM To: Shared-VM-CED <Teams-VM-CED@arlingtonwa.gov> Subject: Permit #6703 - Cascade Valley Hospital Fire Protection This message is from an External Sender This message came from outside the City of Arlington Good morning, I hope you're well. I’m reaching out to request an update on the status of permit application #6703. This project is operating on an accelerated schedule, with a target closeout by the end of the month. Our scope of work involves relocating a single sprinkler head to accommodate a revised room layout. Would it be possible to expedite the review of this permit to help ensure we stay on track without delays? Thank you in advance for your support. Best regards, Luke Thompson Luke Thompson Project Manager 111 Findlay St, Seattle, WA 98108 M: 206.519.8676 | O: 206.232.8569 www.columbiafire.net