Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17601 59th Ave Ne_BLD6329_2025
FIRE SPRINKLER PERMIT APPLICATION Community and Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 Type of Permit: ï² New Installation ï² System Modification ï² Phased Installation Property Address: Suite No.: Project Valuation: Lot #: Parcel ID No.: Preferred Contact: ï² Owner ï² Applicant ï²Contractor Project Description: Owner Name: Phone No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Applicant Name: Phone No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Contractor Name: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation ELECTRONIC FILES OF THE FOLLOW: ï² Complete and Scaled Plans ï² Hydraulic Calculations ï² Equipment Specifications for Each Fire Sprinkler Permit Application ï² Specification Sheets ï² Wiring Diagrams (Point to Point Wiring) ï² Electrical Plans, if applicable FIRE SPRINKLER SYSTEMS (105.7.1, 105.7.4, 105.7.11) ** DEVICES include separate individual portions of a Fire Sprinkler System such as: Sprinklers Heads, Risers, Valves, Pull Stations, and other such devices. (Each piece is one device) PLAN REVIEW FEES Less than $5,000.00 = $100.00 $5,000.00 & over – based on project valuation (Plan Review Fee is 65% of project valuation as calculated per Table 4-1) REV11.2020 Page 1 of 3 REINSPECTION / PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application – review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour (1 hour minimum) $75.00 Hydrostatic Pressure Test (1 test included per permit) $150.00 Cover Inspection (1 cover inspection included per permit) $75.00 Fire Pump (1 fire pump inspection per permit) inspection requires 2 hours $150.00 ï² TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 13/13R) Number of Devices** Device Fee Subtotal 1 to 2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $575.00 = $ > 300 $600.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices = $600.00 + $ = $ Hydraulically Designed Systems Yes ï² / No ï² Yes = Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ ï² NEW COMMERCIAL SYSTEM (NFPA 13/13R) Number of Devices** Device Fee Subtotal 1 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $600.00 = $ > 300 $625.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices = $625.00 + $ = $ Hydraulically Designed Systems Yes ï² / No ï² Yes = Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ ï² RESIDENTIAL (NFPA 13D) Number of Devices** Device Fee Subtotal 1 to 10 $175.00 = $ 11 to 25 $225.00 = $ 26 + $275.00 = $ * NFPA 13D SYSTEM INSTALLED (NOT REQUIRED) Permit Fee Reduced 50% = $ PERMIT FEE SUBTOTAL $ REV2022 Page 2 of 3 ï² HOOD SUPPRESSION SYSTEM Type of System No. of Units Cost per Unit Subtotal Pre-Engineered x $200.00 = $ Custom Engineered x $275.00 = $ PERMIT FEE SUBTOTAL $ ï² STANDPIPE SYSTEM Type of Standpipe No. of Units Cost per Unit Subtotal Class I – new or existing x $150.00 = $ Class II – new or existing x $150.00 = $ PERMIT FEE SUBTOTAL $ ï² FIRE PUMP Fire Pump x $300.00 each = $ PERMIT FEE SUBTOTAL $ ï² SPRAY BOOTHS (105.7) & INDUSTRIAL OVENS (105.7.7) NOTE: SEPARATE SPRINKLER PERMIT REQUIRED Type of Booth No. of Units Cost per Unit Subtotal Pre-Engineered w/documents x $150.00 = $ Site-built or used w/o documents x $250.00 = $ Industrial Oven x $250.00 = $ PERMIT FEE SUBTOTAL $ Plan review fee due at time of submittal TOTAL PERMIT FEE $ PLAN REVIEW FEE $ Processing/Technology Fee $25.00 TOTAL $ I hereby certify that I am the Owner, Applicant, Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. Signature Print Name Date REV2022 Page 3 of 3 RED HAWK FIRE PROTECTION, LLC 801 Valley Ave NW, Suite D Puyallup, WA 98371 (253) 840-9900 REDHAHF901QP MATERIAL SUBMITTALS FOR SNO PUD TI ARLINGTON, WA RHFP JOB NO. 60181 FIRE SPRINKLER SPEC SECTION ###### TABLE OF CONTENTS Material Notes: Any material with the comment "Or Equal" indicates cut sheet represents an exact or similar product to what will be installed. These products generally are generic in nature and due to vender availability, price changes, or other unknowns, a similar product my be selected. All products used will meet all NFPA 13, authority having jurisdiction, and project specifications requirements. Section 1 - Pipe & Fittings Description Make Model Comments Black Steel Sprinkler Pipe - Schedule 10 & 40 Bull Moose N/A Or Equal Threaded Fittings - Ductile Iron ASC - Anvil N/A Or Equal Mechanical Tee - Threaded & Grooved Victaulic Style 920 Flexible Sprinkler Drop - 48" & 72" Victaulic Style AH2 Includes AB2 Bracket Section 2 - Hangers & Attachments Description Make Model Comments All Thread Rod - Plated ASC - Anvil N/A Or Equal Loop/Ring Hanger - Standard Duty nVent - CADDY 115 Or Equal Section 3 - Fire Sprinklers Description Make Model Comments Standard Spray - Pendent, Recessed Reliable F1FR56 (5.6K) Reference Plans for Details Section 4 – Miscellaneous Description Make Model Comments Teflon Tape Argco PTFE Tape Industrial Pipe Dope Argco Tuf-Glide Thread Oil ASC - FPPI Threadfit Clear Oil SECTION 1 Pipe & Fittings SCHEDULE 10, 30, & 40 SPRINKLER PIPE SUBMITTAL DATA SHEET APPROVALS AND SPECIFICATIONS FINISHES AND COATINGS • ASTM A135, Grade A • Schedule 10, 30 & 40 Sprinkler Pipe receives an OD mill coating of water- • ASTM A795, Type E, Grade A based paint which has corrosion protection expected with a painted carbon • Pressure rated to 300 psi steel product, i.e. it would be expected to resist corrosion for an • Underwriters Laboratories— extended and indefinite period in a clean and dry environment and, United States of America as environmental conditions deteriorate, the corrosion protection • Underwriters Laboratories—Canada would also diminish. • Factory Mutual • Schedule 10, 30 & 40 Sprinkler Pipe (black) receives an ID mill coating of • NFPA-13 Eddy Guard II MIC preventative coating. EG2 has been tested at • NFPA-13R independent laboratories to resist bacterial growth and maintain minimal bacterial count after multiple flushes (25) of the pipe. • NFPA-14 • CIVIL DEFENSE APPROVAL— • Schedule 10, 30 & 40 Sprinkler Pipe when Hot Dip Galvanized by ASTM A123 United Arab Emirates and supplied by Bull Moose Tube is UL listed and FM approved. • Made in the United States of America PRODUCT IDENTIFICATION • UL, ULC & FM listed for roll-groove, plain-end and welded joints for wet, dry, • Every length of Bull Moose fire sprinkler pipe features large, easy-to- preaction and deluge sprinkler systems. read, continuous stenciling, clearly identifying the manufacturer, type • LEED v4 Certified of pipe, size, and length. Nominal Pipe Size (inches) 1 1-1/4" 1-1/2" 2" 2-1/2" 3" 4" 6" 8"†10" O.D. (in) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 10.750 I.D. (in) 1.097 1.422 1.682 2.157 2.635 3.260 4.260 6.357 8.249 10.374 Empty Weight (lb/ft) 1.41 1.81 2.09 2.64 3.53 4.34 5.62 9.29 16.94 21.23 Water Filled Weight (lb/ft) 1.800 2.518 3.053 4.223 5.893 7.957 11.796 23.038 40.086 57.874 Schedule 10 C.R.R.* 15.270 9.910 7.760 6.270 4.920 3.540 2.500 1.158 1.805 2.410 Pieces per Lift 91 61 61 37 30 19 19 10 7 7 O.D. (in)  1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 †I.D. (in) 1.049 1.380 1.610 2.067 2.469 3.068 4.026 6.065 8.071 Empty Weight (lb/ft) 1.68 2.27 2.72 3.66 5.8 7.58 10.8 18.99 24.72 Water Filled Weight (lb/ft)  2.055 2.918 3.602 5.114 7.875 10.783 16.316 31.498 50.240 Schedule 40 & 30 C.R.R.*  1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Pieces per Lift 70 51 44 30 30 19 19 10 7 *Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY SUBMITTAL INFORMATION Project Contractor Engineer Specification Reference Date System Type Locations Comments Schedule 10 - Black Schedule 10 - Hot Dip Galvanized Schedule 30 - Black Schedule 30 - Hot Dip Galvanized Schedule 40 - Black Schedule 40 - Hot Dip Galvanized 1819 Clarkson Road, Chesterfield, MO 63017 US: 800.325.4467 | Canada: 800.882.4666 | sales@BullMooseIndustries.com SPF Ductile Iron Threaded Fittings Fig. 3201 90Ëš Elbow Material Specifications Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. Note: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause For Listings/Approval Details and Limitations, visit damage to pipe threads which may cause leakage. Ductile our website at www.asc-es.com or contact an ASC iron fittings should be tightened approximately three turns Engineered Solutionsâ„¢ Sales Representative. beyond hand tight, but no more than four turns. Figure 3201 90Ëš Elbow Maximum Nominal Size Dimension A Approx Wt. Each A Working Pressure ï° In. (mm) psi (kPa) In. (mm) Lbs. (kg) 1 500 1.50 0.62 20 3450 38.10 0.68 1¼ 500 1.75 0.90 32 3450 44.45 0.41 A 1½ 500 1.94 1.20 40 3450 49.276 0.54 2 500 2.25 1.85 50 3450 57.15 0.84 ï° â€“ Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit asc-es.com or contact your local ASC Engineering SolutionsTM Representative. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/MI-1.15 page 1 PS-SUB-3201-v01 20220118 Ductile Iron Threaded Fittings Reducing 90Ëš Elbow Fig. 3201R Material Specifications • Dimensions: ASME B16.3 • Material: ASTM A536 Grade 65-45-12 • Finish: Black • Threads: NPT per ASME B1.20.1 • Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. Note: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile For Listings/Approval Details and Limitations, visit iron fittings should be tightened approximately three turns our website at www.asc-es.com or contact an ASC beyond hand tight, but no more than four turns. Engineered Solutionsâ„¢ Sales Representative. Fig. 3201R Reducing 90° Elbow Nominal Dimensions Approx Size Max. Working Pressure ï° Wt. Each 1 x 2 A B In. (mm) PSI (kPa) In. (mm) In. (mm) Lbs. (kg) 1 x ½ 500 1.26 1.36 0.44 25 x 15 3450 32.00 34.54 0.20 1 x ¾ 500 1.37 1.45 0.52 25 x 20 3450 34.79 36.83 0.24 B 1¼ x ½ 500 1.34 1.53 0.64 32 x 15 34550 34.03 38.86 0.29 2 1¼ x ¾ 500 1.45 1.62 0.72 32 x 20 3450 36.83 41.14 0.33 1¼ x 1 500 1.58 1.67 0.75 32 x 25 3450 40.13 42.41 0.34 A 1 1½ x ½ 500 1.41 1.66 0.64 40 x 15 3450 35.81 42.16 0.29 1 x 2 1½ x ¾ 500 1.52 1.75 0.77 40 x 20 3450 38.61 44.45 0.35 1½ x 1 500 1.65 1.80 0.92 40 x 25 3450 41.91 45.72 0.42 1½ x 1¼ 500 1.82 1.88 1.08 40 x 32 3450 46.22 47.75 0.49 2 x ½ 500 1.49 1.88 1.08 50 x 15 3450 37.84 47.75 0.49 2 x ¾ 500 1.60 1.97 1.24 50 x 20 3450 40.64 50.03 0.56 2 x 1 500 1.73 2.02 1.40 50 x 25 3450 43.94 51.30 0.64 2 x 1¼ 500 1.90 2.10 1.52 50 x 32 3450 48.26 53.34 0.70 2 x 1½ 500 2.02 2.16 1.65 50 x 40 3450 51.30 54.86 0.75 ï° â€“ Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit www.asc-es.com or contact your local ASC Engineered Solutionsâ„¢ Representative. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-11.21 page 1 PS-SUB-320IR-v01 20210106 SPF Ductile Iron Threaded Fittings 45Ëš Elbow Fig. 3202 Material Specifications Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. Note: Ductile iron fittings have higher tensile strength than For Listings/Approval Details and Limitations, visit that of steel pipe. Therefore, over tightening can cause our website at www.asc-es.com or contact an ASC damage to pipe threads which may cause leakage. Ductile Engineered Solutionsâ„¢ Sales Representative. iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. Figure 3202 45Ëš Elbow Maximum Nominal Size Dimension A Approx Wt. Each Working Pressure ï° A In. (mm) psi (kPa) In. (mm) Lbs. (kg) 1 500 1.12 0.46 25 3450 28.44 0.21 1¼ 500 1.29 0.73 32 3450 32.76 0.33 1½ 500 1.43 0.92 A 40 3450 36.32 0.42 2 500 1.68 1.50 50 3450 42.67 0.68 ï° â€“ Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit asc-es.com or contact your local ASC Engineering SolutionsTM Representative. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/MI-1.15 page 1 PS-SUB-3202-v01 20220118 SPF Ductile Iron Threaded Fittings Straight Tee Fig. 3205 Material Specifications Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. Note: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. For Listings/Approval Details and Limitations, visit our website at www.asc-es.com or contact an ASC Engineered Solutionsâ„¢ Sales Representative. Figure 3205 Straight Tee Maximum Nominal Size Dimension A Approx Wt. Each Working Pressure ï° In. (mm) psi (kPa) In. (mm) Lbs. (kg) 1 500 1.50 0.85 A 25 3450 38.10 0.39 1¼ 500 1.75 1.22 32 3450 44.45 0.55 1½ 500 1.94 1.55 40 3450 49.27 0.70 A A 2 500 2.25 2.45 50 3450 57.15 1.11 ï° â€“ Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit asc-es.com or contact your local ASC Engineering SolutionsTM Representative. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/MI-1.15 page 1 PS-SUB-3205-v01 20220118 SPF Ductile Iron Threaded Fittings Reducing Tee Fig. 3205R Material Specifications Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. Note: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron For Listings/Approval Details and Limitations, visit fittings should be tightened approximately three turns beyond hand tight, but no more our website at www.asc-es.com or contact an ASC than four turns. Engineered Solutionsâ„¢ Sales Representative. Figure 3205R Reducing Tee C 2 Nominal Maximum Dimensions Size Approx Wt. B Working Each 3 1 x 2 x 3 Pressure ï° A B C In. (mm) psi (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1 x ½ x 1 500 1.50 1.36 1.50 0.64 A 1 25 x 15 x 25 3450 38.10 34.54 38.10 0.29 1 x 2 x 3 1 x ¾ x 1 500 1.50 1.45 1.50 0.73 25 x 20 x 25 3450 38.10 36.83 38.10 0.33 1 x 1 x ½ 500 1.26 1.26 1.36 0.71 25 x 25 x 15 3450 32.00 32.00 34.54 0.32 Figure 3205R Reducing Tee 1 x 1 x ¾ 500 1.37 1.37 1.45 0.76 25 x 25 x 20 3450 34.80 34.80 36.83 0.34 Nominal Maximum Dimensions Size Approx 1 x 1 x 1¼* 500 1.67 1.67 1.58 0.98 Working Wt. Each 25 x 25 x 32 3450 42.41 42.41 40.13 0.44 1 x 2 x 3 Pressure ï° A B C 1 x 1 x 1½* 500 1.80 1.80 1.65 1.16 In. (mm) psi (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 25 x 25 x 40 3450 45.72 45.72 41.91 0.53 1¼ x 1¼ x ¾ 500 1.45 1.45 1.62 0.92 1¼ x 1 x ½* 500 1.34 1.26 1.53 0.82 32 x 32 x 20 3450 36.83 36.83 41.15 0.42 32 x 25 x 15 3450 34.04 32.00 38.86 0.37 1¼ x 1¼ x 1 500 1.58 1.58 1.67 0.95 1¼ x 1 x ¾ 500 1.45 1.37 1.62 0.90 32 x 32 x 25 3450 40.13 40.13 42.42 0.43 32 x 25 x 20 3450 36.83 34.80 41.15 0.41 1¼ x 1¼ x 1½* 500 1.88 1.88 1.82 1.45 1¼ x 1 x 1 500 1.58 1.50 1.67 1.00 32 x 32 x 40 3450 47.75 47.75 46.22 0.66 32 x 25 x 25 3450 40.13 38.10 42.42 0.45 1¼x 1 x 1¼ 500 1.75 1.67 1.75 1.08 32 x 25 x 32 3450 44.45 42.42 44.45 0.49 1¼ x 1 x 1½ 500 1.88 1.80 1.82 1.42 32 x 25 x 40 3450 47.75 45.72 46.22 0.64 1¼ x 1¼ x ½ 500 1.34 1.34 1.53 0.86 32 x 32 x 15 3450 34.04 34.04 38.86 0.39 ï° â€“ Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit asc-es.com or contact your local ASC Engineering SolutionsTM Representative. *Part supplied as "Bull Head Tee". PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/MI-1.15 page 1 PS-SUB-3205R-v01 20220202 SPF Ductile Iron Threaded Fittings Reducing Tee Fig. 3205R C 2 B 3 A 1 1 x 2 x 3 Figure 3205R Reducing Tee Figure 3205R Reducing Tee Nominal Nominal Size Maximum Dimensions Approx Wt. Size Maximum Dimensions Approx Wt. Working Working Each Each 1 x 2 x 3 Pressure ï° A B C 1 x 2 x 3 Pressure ï° A B C In. (mm) psi (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) In. (mm) psi (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1¼ x 1¼ x 2* 500 2.10 2.10 1.90 1.75 1½ x 1½ x 2* 500 2.16 2.16 2.02 1.98 32 x 32 x 50 3450 53.34 53.34 48.26 0.79 40 x 40 x 50 3450 54.86 54.86 51.30 0.90 1½ x 1 x ½ 500 1.41 1.34 1.66 0.95 2 x 1 x 2 500 2.25 2.02 2.25 2.15 40 x 25 x 15 3450 35.81 34.04 42.16 0.43 50 x 25 x 50 3450 57.15 51.31 57.15 0.98 1½ x 1 x ¾ 500 1.52 1.37 1.75 1.14 2 x 1¼ x 2 500 2.25 2.10 2.25 2.30 40 x 25 x 20 3450 38.61 34.80 44.45 0.52 50 x 32 x 50 3450 57.15 53.34 57.15 1.04 1½ x 1 x 1 500 1.65 1.50 1.80 1.17 2 x 1½ x ½ 500 1.49 1.41 1.88 1.50 40 x 25 x 25 3450 41.91 38.10 45.72 0.53 50 x 40 x 15 3450 37.85 35.81 47.75 0.68 1½ x 1 x 1¼ 500 1.82 1.67 1.88 1.34 2 x 1½ x ¾ 500 1.60 1.52 1.97 1.62 40 x 25 x 32 3450 46.23 42.42 47.75 0.61 50 x 40 x 20 3450 40.64 38.61 50.04 0.73 1½ x 1 x 1½ 500 1.94 1.80 1.94 1.45 2 x 1½ x 1 500 1.73 1.65 2.02 1.64 40 x 25 x 40 3450 49.28 45.72 49.28 0.66 50 x 40 x 25 3450 43.94 41.91 51.31 0.74 1½ x 1¼x ½ 500 1.41 1.34 1.66 1.05 2 x 1½ x 1¼ 500 1.90 1.82 2.10 1.80 40 x 32 x 15 3450 35.81 34.04 42.16 0.48 50 x 40 x 32 3450 48.26 46.23 53.34 0.82 1½ x 1¼ x ¾ 500 1.52 1.45 1.75 1.15 2 x 1½ x 1½ 500 2.02 1.94 2.16 2.00 40 x 32 x 20 3450 38.61 36.83 44.45 0.5 50 x 40 x 40 3450 51.31 49.28 54.86 0.91 1½ x 1¼ x 1 500 1.65 1.58 1.80 1.25 2 x 1½ x 2 500 2.25 2.16 2.25 2.35 40 x 32 x 25 3450 41.91 40.13 45.72 0.57 50 x 40 x 50 3450 57.15 54.86 57.15 1.07 1½ x 1¼ x 2* 500 2.16 2.10 2.02 1.90 2 x 2 x ½ 500 1.49 1.49 1.88 1.60 40 x 32 x 50 3450 54.86 53.34 51.30 0.86 50 x 50 x 15 3450 37.85 37.85 47.75 0.73 1½ x 1½ x ½ 500 1.41 1.41 1.16 1.15 2 x 2 x ¾ 500 1.60 1.60 1.97 1.68 40 x 40 x 15 3450 35.81 35.81 29.46 0.52 50 x 50 x 20 3450 40.64 40.64 50.04 0.76 1½ x 1½ x ¾ 500 1.52 1.52 1.75 1.24 2 x 2 x 1 500 1.73 1.73 2.02 1.85 40 x 40 x 20 3450 38.61 38.61 44.45 0.56 50 x 50 x 25 3450 43.94 43.94 51.31 0.84 1½ x 1½ x 1 500 1.65 1.65 1.80 1.30 2 x 2 x 1¼ 500 1.90 1.90 2.10 2.04 40 x 40 x 25 3450 41.91 41.91 45.72 0.59 50 x 50 x 32 3450 44.45 42.42 44.45 0.93 1½ x 1½ x 1¼ 500 1.82 1.82 1.88 1.48 2 x 2 x 1½ 500 2.02 2.02 2.16 2.18 40 x 40 x 32 3450 46.23 46.23 47.75 0.67 50 x 50 x 40 3450 44.45 42.42 44.45 0.99 ï° â€“ Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit asc-es.com or contact your local ASC Engineering SolutionsTM Representative. *Part supplied as "Bull Head Tee". SPF/MI-1.15 page 2 PS-SUB-3205R-v01 20220202 SPF Ductile Iron Threaded Fittings Cross Fig. 3207 Material Specifications Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. Note: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns For Listings/Approval Details and Limitations, visit beyond hand tight, but no more than four turns. our website at www.asc-es.com or contact an ASC Engineered Solutionsâ„¢ Sales Representative. Figure 3207 Cross Maximum A A Nominal Size Dimension A Approx Wt. Each Working Pressure ï° In. (mm) psi (kPa) In. (mm) Lbs. (kg) A 1 500 1.50 0.98 25 3450 38.10 0.44 1¼ 500 1.75 1.50 32 3450 44.45 068 A 1½ 500 1.94 1.90 40 3450 49.27 0.86 2 500 2.25 2.95 50 3450 57.15 1.34 ï° â€“ Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit asc-es.com or contact your local ASC Engineering SolutionsTM Representative. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/MI-1.15 page 1 PS-SUB-3207-v01 20220118 SPF Ductile Iron Threaded Fittings Reducing Coupling Fig. 3221R Material Specifications Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. Note: Ductile iron fittings have higher tensile strength than For Listings/Approval Details and Limitations, visit that of steel pipe. Therefore, over tightening can cause our website at www.asc-es.com or contact an ASC Engineered Solutionsâ„¢ Sales Representative. damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. Figure 3221R Reducing Coupling Maximum Nominal Size Dimension A Approx Wt. Each Working Pressure ï° In. (mm) psi (kPa) In. (mm) Lbs. (kg) 1 x ½ 500 1.69 0.39 A 25 x 15 3450 42.92 0.18 1 x ¾ 500 1.69 0.53 25 x 20 3450 42.92 0.24 1¼ x ¾ 500 2.06 0.64 32 x 20 3450 52.32 0.29 ï° â€“ Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit asc-es.com or contact your local ASC Engineering SolutionsTM Representative. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/MI-1.15 page 1 PS-SUB-3221R-v01 20220118 SPF Ductile Iron Threaded Fittings Bushings Fig. 3283 Material Specifications Dimensions: ASME B16.14 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. Note: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause For Listings/Approval Details and Limitations, visit damage to pipe threads which may cause leakage. Ductile our website at www.asc-es.com or contact an ASC iron fittings should be tightened approximately three turns Engineered Solutionsâ„¢ Sales Representative. beyond hand tight, but no more than four turns. Figure 3283 Bushings Nominal Size Maximum Dimensions C Approx Wt. Male (M) x Working Style Each F B Pressure ï° A B C Female (F) In. (mm) psi (kPa) In. (mm) In. (mm) In. (mm) - Lbs. (kg) A 1 x ½ 500 0.75 0.25 1.42 0.22 M Outside 25 x 15 3450 19.05 6.35 36.06 0.10 Inside Head 1 x ¾ 500 0.75 0.25 1.42 0.17 Outside 25 x 20 3450 19.05 6.35 36.06 0.08 1¼ x 1 500 0.80 0.28 1.76 0.28 Outside 32 x 25 3450 20.32 7.11 44.70 0.13 1½ x 1 500 0.83 0.31 2.00 0.45 C Outside 40 x 25 3450 21.08 7.874 50.80 0.20 F B 1½ x 1¼ 500 0.83 0.31 2.00 0.30 Outside 40 x 32 3450 21.08 7.874 50.80 0.14 A 2 x 1 500 0.88 0.41 1.95 0.67 50 x 25 3450 22.35 10.414 49.43 Inside 0.30 M 2 x 1¼ 500 0.88 0.34 2.48 Outside 0.73 Outside Head 50 x 32 3450 22.35 8.636 62.99 0.33 2 x 1½ 500 0.88 0.34 2.48 0.61 Outside 50 x 40 3450 22.35 8.636 62.99 0.28 ï° â€“ Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit asc-es.com or contact your local ASC Engineering SolutionsTM Representative. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/MI-1.15 page 1 PS-SUB-3283-v01 20220118 SPF Ductile Iron Threaded Fittings Coupling Fig. 3221 Material Specifications Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. Note: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. For Listings/Approval Details and Limitations, visit our website at www.asc-es.com or contact an ASC Engineered Solutionsâ„¢ Sales Representative. Figure 3221 Coupling Maximum Nominal Size Dimension A Approx Wt. Each Working Pressure ï° A In. (mm) psi (kPa) In. (mm) Lbs. (kg) 1 500 1.67 0.40 25 3450 42.42 0.18 1¼ 500 1.93 0.57 32 3450 49.02 0.26 1½ 500 2.15 0.75 40 3450 54.61 0.34 2 500 2.53 1.15 50 3450 64.26 0.52 ï° â€“ Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit asc-es.com or contact your local ASC Engineering SolutionsTM Representative. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/MI-1.15 page 1 PS-SUB-3221-v01 20220118 SPF Ductile Iron Threaded Fittings Cored Plug Fig. 3388 Material Specifications Dimensions: ASME B16.14 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. ï° Pressure - Temperature Ratings in accordance with ASME B16.3 Class 150 Note: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause For Listings/Approval Details and Limitations, visit damage to pipe threads which may cause leakage. Ductile our website at www.asc-es.com or contact an ASC iron fittings should be tightened approximately three turns Engineered Solutionsâ„¢ Sales Representative. beyond hand tight, but no more than four turns. Figure 3388 Cored Plug Maximum Approx. Nominal Size Dimension A Working Pressure ï° Wt. Each In. (mm) psi (kPa) In. (mm) Lbs. (kg) ½* 500 0.94 0.10 15 3450 23.87 0.05 ¾ 500 1.07 0.17 A 20 3450 27.17 0.08 1 500 1.25 0.28 25 3450 31.75 0.13 1¼ 500 1.36 0.44 32 3450 34.54 0.20 1½ 500 1.45 0.62 40 3450 36.83 0.28 2 500 1.56 0.91 50 3450 39.62 0.41 ï° â€“ Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit asc-es.com or contact your local ASC Engineering SolutionsTM Representative. *Part supplied as Solid Plug. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/MI-1.15 page 1 PS-SUB-3388-v01 20220124 SPF Ductile Iron Threaded Fittings Cap Fig. 3224 Material Specifications Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. Note: Ductile iron fittings have higher tensile strength than For Listings/Approval Details and Limitations, visit that of steel pipe. Therefore, over tightening can cause our website at www.asc-es.com or contact an ASC damage to pipe threads which may cause leakage. Ductile Engineered Solutionsâ„¢ Sales Representative. iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. Figure 3224 Cap Maximum Nominal Size Dimension A Approx Wt. Each Working Pressure ï° In. (mm) psi (kPa) In. (mm) Lbs. (kg) 1 500 1.16 0.32 25 3450 29.46 0.15 A 1¼ 500 1.28 0.43 32 3450 32.51 0.20 1½ 500 1.33 0.60 40 3450 33.78 0.27 2 500 1.45 0.91 50 3450 36.83 0.41 ï° â€“ Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit asc-es.com or contact your local ASC Engineering SolutionsTM Representative. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/MI-1.15 page 1 PS-SUB-3224-v01 20220118 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T Bolted Branch Outlets STYLES 920 AND 920N Victaulic Mechanical-T Outlet provides a direct branch connection at any location a hole can EN 10311 BS EN 10311 LPS 1219: Issue 3.1 be cut in pipe. The hole is cut oversize to receive a “holefinder†locating collar which secures CPR (EU) CPR (UK) Cert/LPCB Ref. 104-1a/11 the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. No. 305/2011 2019 No. 465 104-1a/26 Cross-type connections can be achieved by utilizing two upper housings of the same style and SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on STYLES 920 AND 920N STYLE 920 CROSS PVC plastic pipe. PATENTED Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap II® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. • Optional: Hot dipped galvanized Gasket: (Specify choice*) • Grade “E†EPDM EPDM (Green color code). Temperature range –30°F to +230°F/–34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade “T†nitrile Nitrile (Orange color code). Temperature range –20°F to +180°F/–29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are s ervices for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a l isting of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. __________________________ Submitted By ________________________ Spec Sect ____________ Para __________ Location ____________________________ Date ________________________________ Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2024 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_Q 11.02_1 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max. Work Approx. Size No. Pressure@ Dimensions Weight Each Run × Branch Hole V ‡ # V ‡ Female Nominal Size 920 Diameter T** Thd. Grv. W Y Z Thd. Grv. Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. Y Z mm 920N kPa -0.00 mm mm mm mm mm mm kg kg 2 1/2 (a) ¤ 500 1.50 2.00 2.53 1.61 5.35 2.75 3.1 × 920N — — 50 15 3450 38.1 51 64 41 136 70 1.5 V 3/4 (a) ¤ 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 920N — — 20 3450 38.1 50 64 41 136 70 1.5 1 (a) ¤ 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 920N — — W 25 3450 38.1 47 64 41 136 70 1.4 1 1/4 (a) †¤ 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 920N GROOVED OUTLET 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1 1/2 (a) †¤ 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 920N 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 2 1/2 1/2 (a) §¤ 500 1.50 2.21 2.74 1.82 5.64 2.75 3.0 Y Z × 920N — — 65 15 3450 38.1 56 70 46 143 70 1.4 3/4 (a) §¤ 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 920N — — V 20 3450 38.1 55 70 46 143 70 1.4 T 1 (a) §¤ 500 1.50 2.06 2.74 1.82 5.64 2.75 2.9 920N — — 25 3450 38.1 52 70 46 143 70 1.4 W 1 1/4 †(a) ¤ 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 920N 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 1 1/2 †(a) ¤ 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 FEMALE THREADED OUTLET 920N 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 1/2 (a) 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 76.1 × 920N — — 15 2065 38.1 56 70 57 164 81 1.8 • Provides a direct branch connection at 3/4 (a) 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 920N — — any location where a hole can be cut 20 2065 38.1 56 70 57 164 81 1.8 in the pipe 1 (a) 920N 300 1.50 2.07 2.75 — 2.25 6.46 3.18 3.8 — 25 2065 38.1 53 70 57 164 81 1.7 • A pressure responsive gasket provides 1 1/4 (a) ¤ 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 920N the seal 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 1/2 (a) ¤ 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 920N • Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 Mechanical-T cross assemblies 3 × 1/2 (a) ¤ 920N 500 1.50 2.52 3.05 — 2.28 6.15 2.75 3.4 — 80 15 3450 38.1 64 78 58 156 70 1.6 • Pressure rated up to 500 psi/3450 kPa 3/4 (a) ¤ 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 920N — — on steel pipe; also available for use 20 3450 38.1 63 78 58 156 70 1.6 with HDPE pipe 1 (a) 920N 500 1.50 2.38 3.06 — 2.28 6.15 2.75 3.3 — 25 3450 38.1 61 78 58 156 70 1.6 • Sizes from 2 × ½"/50 × 15 mm 1 1/4 (a) †¤ 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 through 8 × 4"/200 × 100 mm 32 (b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 1 1/2 (a) †¤ 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 920N 40 (b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2 (a) ¤ 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 920N 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 3 1/2 2 500 2.50 3.00 3.75 2.44 6.72 3.88 3.8 × 920N — — 90 50 3450 63.5 76 95 62 171 99 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG. 3 Style 920 and Style 920N housings cannot be ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). mated to one another †Available with grooved or female threaded outlet. Specify choice on order. to achieve cross connections. ‡ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT†clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ¤ LPCB approved for fire protection services Ø Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2024 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_2 REV_Q CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max. Work Approx. Size No. Pressure@ Dimensions Weight Each Run × Branch Hole V ‡ # V ‡ Female Nominal Size 920 Diameter T** Thd. Grv. W Y Z Thd. Grv. Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. Y Z mm 920N kPa -0.00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 2 4 1/2 (a) ¤ 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 V 100 × 15 920N 3450 38.1 77 90 — 68 178 70 1.8 — 3/4 (a) ¤ 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 920N — — 20 3450 38.1 76 90 68 178 70 1.8 W 1 (a) ¤ 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 920N — — 25 3450 38.1 73 90 68 178 70 1.8 GROOVED OUTLET 1 1/4 (a) †¤ 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 920N 32 (b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 1 1/2 (a) †¤ 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 920N 40 (b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 Y Z 2 (a) †¤ 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 920N 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 V 2 1/2 (a) †500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 920 T 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 500 2.75 2.88 4.00 2.69 7.34 4.63 6.4 76.1 mm 920 — — W 3450 69.9 73 102 68 186 118 2.9 3 (a) †500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 920 80 3450 88.9 84 114 105 68 196 130 3.8 2.9 FEMALE THREADED OUTLET 1 1/4 (a)¤ 500 1.75 3.08 3.78 2.63 7.64 3.05 5.0 108.0 × 920N — — 32 3450 44.5 78 96 67 194 78 2.3 1 1/2 (a)¤ 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 • Provides a direct branch connection at 920N — — 40 3450 50.8 83 102 67 194 83 2.3 any location where a hole can be cut 2 (a) 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 920N — — in the pipe 50 3450 63.5 83 102 67 194 102 1.9 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 76.1 mm 920 • A pressure responsive gasket provides 3450 69.9 73 102 102 67 194 109 3.6 3.5 the seal 3 (a) 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 920 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 • Request Publication 11.03 for 5 1 1/2 (a) †500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 × 920 Mechanical-T cross assemblies 125 40 3450 50.8 102 121 121 80 246 94 3.4 3.4 2 (a) †500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 920 • Pressure rated up to 500 psi/3450 kPa 50 3450 63.5 102 121 121 80 246 111 3.7 3.6 on steel pipe; also available for use 2 1/2 (a) †500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 920 with HDPE pipe 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 500 2.75 3.75 4.75 3.16 9.70 4.63 8.0 76.1 mm ¤ 920 — — • Sizes from 2 × ½"/50 × 15 mm 3450 69.9 95 121 80 246 118 3.6 through 8 × 4"/200 × 100 mm 3 (a) †920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 500 2.50 3.75 4.50 3.17 8.00 3.88 8.0 133.0 × 920N — — 50 3450 63.5 95 114 81 203 99 3.6 3 500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 920 — — 80 3450 88.9 97 127 76 240 135 3.6 TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be †Available with grooved or female threaded outlet. Specify choice on order. mated to one another ‡ Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT†clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ¤ LPCB approved for fire protection services Ø Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2024 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_Q 11.02_3 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max. Work Approx. Size No. Pressure@ Dimensions Weight Each Run × Branch Hole V ‡ # V ‡ Female Nominal Size 920 Diameter T** Thd. Grv. W Y Z Thd. Grv. Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. Y Z mm 920N kPa -0.00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 3 1 1/2 †500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 V 139.7 × 40 920N 3450 50.8 96 114 — 84 209 83 3.2 — 2 †500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 920N — — 50 3450 63.5 95 114 84 209 99 4.1 W 6 1 1/4 (a) 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 × 920N 150 32 (b) 3450 44.5 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 1 1/2 (a) †¤ 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 920N 40 (b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2 (a) †¤ 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 920N 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 Y Z 2 1/2 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 920 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 V 500 2.75 4.15 5.21 3.69 10.51 4.63 8.4 76.1 mm ¤ 920 — — T 3450 69.9 105 132 94 267 118 3.8 3 (a) †500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 920 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 W 4 (a) †¤ 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 920 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET 1 1/2 (a) 500 2.00 4.41 5.13 3.63 9.40 3.25 7.8 159.0 × 920N — — 40 3450 50.8 112 130 92 239 83 3.5 2 (a) 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 920N — — • Provides a direct branch connection at 50 3450 63.5 111 130 92 239 99 3.6 any location where a hole can be cut 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 76.1 mm 920 in the pipe 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 920 • A pressure responsive gasket provides 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 the seal 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 108.0 mm 920 — — 3450 114.3 113 137 92 239 155 4.5 • Request Publication 11.03 for 4 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 920 — — Mechanical-T cross assemblies 100 3450 114.3 96.80 146 92 239 159 8.2 TABLE CONTINUED ON PG. 5 • Pressure rated up to 500 psi/3450 kPa ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). on steel pipe; also available for use †Available with grooved or female threaded outlet. Specify choice on order. with HDPE pipe ‡ Center of run to end of fitting. • Sizes from 2 × ½"/50 × 15 mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 × 4"/200 × 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT†clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ¤ LPCB approved for fire protection services IMPORTANT NOTES: Ø Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2024 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_4 REV_Q CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max. Work Approx. Size No. Pressure@ Dimensions Weight Each Run × Branch Hole V ‡ # V ‡ Female Nominal Size 920 Diameter T** Thd. Grv. W Y Z Thd. Grv. Inches or psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. Y Z mm 920N kPa -0.00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 4 1 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 V 165.1 × 25 920N 3450 38.1 99 116 — 96 237 70 3.6 — 1 1/4 ¤ 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 920N — — 32 3450 44.5 113 130 96 237 83 3.8 W 1 1/2 (a) †¤ 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 920N 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 GROOVED OUTLET 2 (a) †500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 920N 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 76.1 mm 920 3450 69.9 110 130 132 92 267 118 3.9 3.4 Y Z 3 (a) †Ø 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 920 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 V 4 (a) †¤ 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 920 T 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 2 (a) †500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 × 920 200 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 W 2 1/2 (a) †500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 920 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET 500 2.75 5.25 6.25 4.81 12.42 4.56 11.6 76.1 mm ¤ 920 — — 3450 69.9 133 159 122 316 116 5.3 3 (a) †¤ 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 920 • Provides a direct branch connection at 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4 (a) †¤ 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 920 in the pipe 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). • A pressure responsive gasket provides †Available with grooved or female threaded outlet. Specify choice on order. the seal ‡ Center of run to end of fitting. • Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings.` (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT†clearly on order. • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. with HDPE pipe § Vds approved for fire protection services ¤ LPCB approved for fire protection services • Sizes from 2 × ½"/50 × 15 mm Ø Approved for use in China by Tianjin Approvals Company. through 8 × 4"/200 × 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2024 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_Q 11.02_5 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-T fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. 2 CV and Kv Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for CV /Kv Values: ∆P = Q2 Where: Where:Where: 1 C 2 Q = Flow (GPM) Q = Flow (mQ = Fl3/hr)ow (m3/hr) v ∆P = Pressure Drop (psi) ∆P = Pressure Drop (Bar) ∆P = Pressure Drop (Bar) Q = C x ∆P C = Flow Coefficient v v Kv = Flow CoefficientK = Flow Coefficient v Exaggerated for clarity Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe (per UL 213, Sec. 16) OUTLET SIZE (C = 120)ŧ FT CV/KV Values NOMINAL ACTUAL DIAMETER O.D. In/mm In/mm GROOVED THREADED GROOVED THREADED 1/2 0.840 11 - 2 - 15 21.3 9.4 3/4 1.050 16 - 4 - 20 26.7 13.7 1 1.315 21 25 33.7 3** 8 - 1.8 1 1/4 1.660 50 48 5 1/2 6 32 42.7 42.9 41.1 1 1/2 1.900 53 53 11 11 40 48.3 45.4 45.4 2 2.375 112 104 9 10 1/2 50 60.3 96 89.1 2 1/2 2.875 119 150 20 12 1/2 65 73.0 102 128.5 3.000 161 76.1 mm 16* - - 76.1 138.1 3 3.500 249 237 14 15 1/2 80 88.9 213.4 203.1 4 4.500 421 401 20 22 100 114.3 360.8 343.6 ŧ Hazen-Williams coefficient of friction is 120. * Pipe with a wall thickness of 0.165in./4.2mm. ** 1" FireLockâ„¢ Innovative Groove System (IGS) outlet www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2024 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_6 REV_Q CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Approval Agency Run Size Outlet Size Pipe Rated Working Pressures – psi/kPa Actual Nominal Outside Vds Size Diameter Inches/mm Inches/mm Inches/mm Schedule UL ULC FM LPCB (Style 920) (Style 920N) 21/2 - 6 2.875 - 6.625 400 400 400 290 232 362 All 10, 40 65 - 150 73.0 - 168.3 2755 2755 2755 1999 1599 2496 21/2 - 4 2.875 - 4.500 300 300 300 290 232 362 All DF 65 - 100 73.0 - 114.3 2065 2065 2065 1999 1599 2496 21/2 - 4 2.875 - 4.500 300 300 300 290 232 362 All SF 65 - 100 73.0 - 114.3 2065 2065 2065 1999 1599 2496 6 6.625 300 300 250 290 232 362 3, 4 10 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 300 300 300 290 232 362 3,4 30, 40 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 400 145 21/2 10, 40 — — — — 200 219.1 2755 1000 8 8.625 300 250 145 3,4 10 — — — 200 219.1 2065 1724 1000 8 8.625 300 300 145 3,4 30, 40 — — — 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4 - 8"/100 - 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4"/100 mm, 5"/125 mm, 6"/150 mm and 8"/200 mm diameter pipe. The Style 931 comes with a 2 ½"/65 mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2024 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_Q 11.02_7 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the I-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV Q UPDATED 08/2024 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2024 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_8 Victaulic® VicFlexâ„¢ Sprinkler Fittings Series AH2 and AH2-CC Braided Flexible Hoses 10.85 Series AH2 Series AH2-CC 1.0 PRODUCT DESCRIPTION Available Sizes by Component Series AH2 1"/DN25 ID Braided Hose: 31, 36, 48, 60, 72"/790, 915, 1220, 1525, 1830 mm. Note: length includes adapter nipple and 5.75"/140 mm straight reducer. Series AH2-CC 1"/DN25 ID Braided Hose: 31, 36, 48, 60, 72"/790, 915, 1220, 1525, 1830 mm. Note: length includes captured coupling and 5.75"/140 mm straight reducer. Connections • From Branchline • ¾"/20mm BSPT female thread (VdS only) • 1 ¼"/32mm BSPT female thread (LPCB only) • 1"/25mm NPT or BSPT female Thread • 1"/25mm Grooved IGS (refer to Submittal 10.54 for additional IGS connections) • No. 116 CPVC Adapter (1"/25mm Female CPVC Socket x 1"/25mm Grooved IGS) • No. 142 Welded Outlet • Style 922 Outlet-T • Style 920N Mechanical-T Outlet • No. 65 Grooved End of Run Fitting • Hose Inlet • 1"/25mm Grooved IGS • 1"/25mm NPT or BSPT male thread • ¾"/20mm BSPT male thread (VdS only) • 1 ¼"/32mm BSPT male thread (LPCB only) ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. victaulic.com 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. 1 victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) • Sprinkler Reducer • Sprinkler Connection: 1/2" and ¾"/15mm and 20mm NPT or BSPT female thread • Straight Lengths: 5.75", 9", 13"/140mm, 230mm, 330mm • 90Ëš Elbows • Standard Short • Low Profile Short • Standard Long • Low Profile Long (Short elbows typically used with concealed sprinklers. Long elbows typically used with recessed pendent sprinklers) Brackets • Style AB2 for suspended and hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style AB3 for surface mount applications, wood, metal and block walls, or ceilings • Style AB4 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment • Style AB5 for hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment • Style AB7 for suspended and hard-lid ceilings • Style AB7 Adjustable for suspended and hard-lid ceilings • Style AB10 for Armstrong® TechZoneâ„¢ ceilings • Style AB11 for lay-in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 90° low profile elbows) • Style AB12 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to 4"/100mm. • Style ABBA bracket for suspended, exposed, and hard-lid ceilings • Style ABMM bracket for surface mount and stand off-mount applications, wood, metal and block walls, or ceilings and hard-lid ceilings • Strut channel and pipe clamp, not supplied by Victaulic Maximum Working Temperature • 225°F/107°C • 150°F/65°C (No. 116 CPVC Adapter) Maximum Working Pressure • 200 psi/1375 kPa (FM Approval) • 175 psi/1206 kPa (cULus Listed) • 1600 kPa/232 psi (VdS/LPCB Approved) • 1.4 MPa (CCCf Approved) • 175 psi/1206 kPa (No. 116 CPVC Adapter) Minimum Bend Radius • 7"/178 mm (FM/CCCf Approval) • 2"/51 mm (cULus Listed) • 3"/76.2 mm (VdS/LPCB Approved) 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 2 victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) Maximum Allowable Sprinkler K-Factors • FM (1/2"/15 mm reducer) K5.6/8,1 (S.I.), (¾"/20 mm reducer) K14.0/20,2 (S.I.) • cULus (1/2"/15 mm reducer) K8.0/11,5 (S.I.), (¾"/20 mm reducer) K14.0/20,2 (S.I.) • VdS/LPCB (1/2"/15 mm reducer) K5.6/8,1 (S.I.), (¾"/20 mm reducer) K8.0/11,5 (S.I.) 2.0 CERTIFICATION/LISTINGS LPS 1261: Issue 1.2 Cert/LPCB Ref. 104l/01 104l/04 NOTE • The VicFlex Series AH2 Hose has been tested and evaluated by Spears® for acceptable use with Spears® CPVC Products and is therefore covered under the Spears® FlameGuard® Installer Protection Plan. 3.0 SPECIFICATIONS – MATERIAL Series AH2: Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Nut and Nipple: Carbon Steel, Zinc-Plated Reducer (½"/15 mm or ¾"/20 mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated Series AH2-CC: Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Coupling Retainer Ring: Polyethelene Nut: Carbon Steel, Zinc-Plated Reducer (½"/15 mm or ¾"/20 mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: • Orange enamel (North America, Asia Pacific). • Red enamel (Europe). • Hot dipped galvanized. Gasket:1 Grade “E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type III Finish No. 116 Adapter Fitting: CPVC and Brass Seal: Victaulic EPDM 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 3 victaulic.com 4.0 DIMENSIONS Product Details - Series AH2 Braided Hose Item Description 2 1 Flexible Hose 5 1 6 8 7 3 4 9 2 Isolation Ring 3 Gasket 4 Nut 5 Adapter Nipple A 6 Braid B 7 Collar/Weld Fitting 8 Sleeve 9 Reducer Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31 25.3 31 790 641 790 36 31.3 36 915 794 915 48 42.3 48 1219 1073 1220 60 54.3 60 1525 1378 1525 72 66.3 72 1830 1683 1830 Series AH2-CC Braided Hose Item Description 1 Flexible Hose 5 2 Isolation Ring 6 8 2 3 4 3 Gasket 1 7 9 4 Nut 5 Captured Coupling 6 Braid 7 Collar/Weld Fitting A 8 Sleeve B 9 Reducer Hose Length A B inches inches inches mm mm mm 31 24.5 29.8 790 622 757 36 29.5 34.8 915 749 884 48 41.5 46.8 1219 1054 1189 60 53.5 58.8 1525 1359 1494 72 65.5 70.8 1830 1664 1798 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 4 victaulic.com 4.0 DIMENSIONS (CONTINUED) Standard Reducer – – – – – – – – – –4– –3– –2– –1 5.75"/140 mm straight reducer Optional Reducers 2.62"/ 66.5 mm 2.62"/ 66.5 mm 7.25"/ 184.2 mm 5.50"/ 6.57"/ 139.7 mm 166.9 mm 5.00"/ 127.0 mm 9.0"/229 mm straight reducer 4.83"/ 3.25"/ 122.7 mm 82.6 mm 13.0"/330 mm straight reducer Short 90° elbow reducer Long 90° elbow reducer NOTE • The Short 90° elbow reducer is typically used with concealed sprinklers while the longer 90° elbow is typically used in the installation of recessed pendent sprinklers. • FM/VdS Approved only. Low Profile 5.25"/ 4.59"/ 133 mm 3.50"/ 3.63"/ 116 mm 2.84"/ 89 mm 92 mm 1.88"/ 72 mm 48 mm 1.4"/ 1.4"/ 36 mm 36 mm Short 90° elbow reducer Long 90° elbow reducer NOTE • Style AB11: When low profiles elbows are with the Style AB11 bracket, the Low Profile Short Elbow is typically used with concealed sprinklers while the Low Profile Long Elbow is typically used in the installation of recessed pendent sprinklers. No. 116 CPVC Adapter E to E NOTES • E to E is 3.0"/76.0 mm • The No. 116 CPVC Adapter has 2 ft. (0.6 m) EQL of 1" Schedule 40 pipe. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 5 victaulic.com 4.1 DIMENSIONS VicFlex Brackets Style AB2 3 • Suspended Ceilings • Hard-Lid Ceilings 2 Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 1 2 Patented Vertically Adjustable Center Bracket 3 End Bracket NOTE 3 • Both sizes FM/VdS/LPCB Approved, cULus listed Style AB3 • Surface Mount Applications • FM/LPCB Approved Style AB4 • Hard-Lid Ceilings with Hat furring 1 channel grid system 2 3 Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 3 End Bracket for Hat Furring Channel NOTE • Both sizes FM/VdS/LPCB Approved, cULus listed. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 6 victaulic.com 4.2 DIMENSIONS VicFlex Brackets Style AB5 3 • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 2 2 Patented Vertically Adjustable Center Bracket 3 End Bracket 1 NOTE • Both sizes FM/VdS/LPCB Approved, cULus listed. 3 Style AB7 3 • Suspended Ceilings • Hard-Lid Ceilings Item Description 2 1 24"/610 mm or 48"/1219 mm Square Bar 2 Patented 1-Bee2® Center Bracket 1 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved. 3 Style AB7 Adjustable 3 • Suspended Ceilings • Hard-Lid Ceilings 2 Item Description 1 1 700 mm or 1400 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket (adjustable) NOTE 3 • Both sizes FM/VdS/LPCB Approved. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 7 victaulic.com 4.3 DIMENSIONS VicFlex Brackets Style AB10 • Suspended ceilings 3 2 • Armstrong® TechZoneâ„¢ 1 3 Item Description 1 6"/152 mm Square Bar 2 Patented 1-Bee2® Center Bracket 3 End Bracket NOTE • FM/VdS/LPCB Approved, cULus listed. 3 Style AB11 • Suspended ceilings • Hard-Lid ceilings 2 Item Description 1 24"/610 mm or 48"/1219 mm Square Bar 1 2 Patented 1-Bee2® Center Bracket 3 End Bracket 3 NOTE • FM/VdS Approved, cULus listed. Style AB12 2 • Suspended ceilings • Hard-Lid ceilings Item Description 1 Style AB12 Bracket Body 1 2 #2 Square Drive Set Screw NOTE • FM/VdS Approved. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 8 victaulic.com 4.3 DIMENSIONS (CONTINUED) VicFlex Brackets Style ABBA 1 • Floor-above mount 3 • Cantilever mount • Temporary mount in exposed ceilings 2 Item Description 1 Style ABBA Mounting Plate 2 Style ABBA Square Bar Cap Screw, Serated Flange, M6 x 1 x 20, 3 T25 Torx Drive Recessed 5 4 Style ABMM Bracket Body 4 Cap Screw, Serated Flange, M6 x 1 x 15.24, 5 T25 Torx Drive Recessed NOTE • FM Approved. Style ABMM 2 • Surface mount • Stand-off mount Item Description 1 1 Style ABMM Bracket Body Cap Screw, Serated Flange, M6 x 1 x 15.24, 2 T25 Torx Drive Recessed NOTE • FM Approved. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 9 victaulic.com 4.4 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket R See Table L Bracket Assembly Style AB2 4.3"/ 23â„8"/60.33 mm 111 mm 2"/50.80 mm 5/8"/15.9 mm Typical ceiling tile 1.7"/43 mm Typical ceiling grid Finished surface 24"/610 mm or 48"/1219 mm See note on Center V2707 ¾"/19 MM MAX. RECESS V2707 MAX. EXTENSION Hose Clearance Chart Straight Reducer Long Elbow Short Elbow V2707 V3802 V2707 V3802 ¾" ½" ¾" ½" V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess ¾" Max Recess ½" Max Recess ¾" Max Recess ½" Max Recess inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm "R" Minimum 2.0 3.0 7.0 – Bend Radius 50 80 175 "A" Minimum Required 8.6 10.1 9.6 11.1 13.6 15.1 5.8 5.8 Installation 218 269 244 281 345 383 147 147 Space NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 10 victaulic.com 4.5 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket R See chart A See Chart Bracket Assembly #10 Screw Style AB2 211â„16"/68 mm 1.8"/45 mm max. hole 23â„8"/60 mm min. hole 2" × 4" Stud 3½"/ 89 mm Finished 5/8"/16 mm Typical 16"/406 mm C/C ceiling Typical drywall V38 ½"/13 mm MAX. RECESS V38 MAX. EXTENSION Hose Clearance Chart Straight Reducer V2707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 ¾" | 20 mm ½" | 13 mm ¾" | 20 mm ¾" | 20 mm ½" | 13 mm ¾" | 20 mm ¾" | 20 mm ½" | 13 mm ¾" | 20 mm Max Recess" Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm "R" Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 "A" Minimum Required 6.2 7.6 6.1 7.2 8.6 7.1 11.2 12.6 11.1 Installation 158 193 155 183 218 180 285 320 282 Space Hose Clearance Chart Long Elbow Short Elbow V2707 V2709 V3802 ¾" | 20 mm ¾" | 20 mm ½" | 13 mm Max Recess Sidewall Max Recess inches inches inches mm mm mm "R" Minimum – Bend Radius "A" Minimum Required 3.3 3.6 3.3 Installation 84 91 84 Space NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 11 victaulic.com 4.6 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB4 Bracket R See chart A See Chart Bracket assembly Style AB4 4.1"/ 23â„8"/60 mm Typical Hat 104 mm max. hole Channel 2"/51 mm #10 Screw grid min. hole 7â„8"/23 mm Finished ceiling 5â„8"/16 mm Typical drywall Typical 16"/406 mm C/C V27 ¾"/19 mm MAX. RECESS V27 MAX. EXTENSION Hose Clearance Chart Straight Reducer Long Elbow Short Elbow V2707 V3802 V2707 V3802 ¾" ½" ¾" ½" V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess ¾" Max Recess ½" Max Recess ¾" Max Recess ½" Max Recess inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm "R" Minimum 2.0 2.0 3.0 3.0 7.0 7.0 – Bend Radius 50 50 80 80 175 175 "A" Minimum Required 8.8 10.2 9.8 11.2 13.8 15.2 8.0 5.9 Installation 224 259 249 285 351 386 203 150 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 12 victaulic.com 4.7 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB5 Bracket R See chart A See chart Bracket assembly Style AB5 2.3"/ 57 mm 23â„8"/60 mm 2" × 4" max. hole metal stud 2"/51 mm 35â„8"/ min. hole 92 mm Finished 5/8"/16 mm ceiling Typ. Drywall Typical 16"/406 mm C/C V27 ¾"/19 mm MAX. RECESS V27 MAX. EXTENSION Hose Clearance Chart Straight Reducer "V2707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 ¾" | 20 mm ½" | 13 mm ¾" | 20 mm ¾" | 20 mm ½" | 13 mm ¾" | 20 mm ¾" | 20 mm ½" | 13 mm ¾" | 20 mm Max Recess" Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm "R" Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 "A" Minimum Required 6.0 7.7 6.1 7.0 8.7 7.1 11.0 12.7 11.1 Installation 158 196 155 178 221 180 279 323 282 Space Hose Clearance Chart Low-Profile Long Elbow Long Elbow Short Elbow V2707 V3802 V2709 V3802 V3802 ¾" | 20 mm ½" | 13 mm ¾" | 20 mm ½" | 13 mm ½" | 13 mm Max Recess Max Recess Sidewall Max Recess Max Recess inches inches inches inches inches mm mm mm mm mm "R" Minimum – Bend Radius "A" Minimum Required 3.5 4.9 3.6 2.9 3.3 Installation 89 124 91 74 84 Space NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 13 victaulic.com 4.8 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) 23â„8"/60 mm 211â„16"/68 mm Bracket max. hole max. hole Assembly 2"/51 mm 23â„8"/60 mm A Style AB11 min. hole min. hole See Chart 3.0"/ 76 mm 1.7"/43 mm Finished Typical 5/8"/15.9 mm ceiling face ceiling grid Typical ceiling tile See Note 24"/610 mm or V27 V38 48"/1219 mm on center Pendent Hose Clearance Chart Low-Profile Low-Profile Long Elbow Short Elbow V2707 V3802 ¾" | 20 mm ½" | 13 mm Max Recess" Max Recess inches inches mm mm "A" Minimum Required 4.0 3.9 Installation 102 99 Space NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 14 victaulic.com 4.9 DIMENSIONS Clearances Style AB12 and ABBA Bracket Suspended Ceiling Grid with Recessed Sprinkler with Suspended Ceiling Grid with Recessed Sprinkler and Low Profile Short Elbow Straight 5.75"/140 mm Reducer Unfinished Ceiling Face 11â„8 inch/ 29 mm R Nominal length 14"/355.6 mm "A" Unfinished See Table 11â„8 inch/ Ceiling Face 29 mm 1â„8 inch/ 3 mm 1â„8 inch/ "A" 3 mm See Table "B" See Table "B" See Table Finished Face of Finished Face of 5/8-inch/16-mm 5/8-inch/16-mm Typical Ceiling Typical Ceiling V2707 ½"/12.7 mm MAX. RECESS V2707 ¾"/19 mm MAX. RECESS Low Profile Low Profile Standard Standard Standard Dimension Short Elbow Long Elbow Short Elbow Long Elbow Straight Reducer ¾"/19 mm ¾"/19 mm ¾"/19 mm ¾"/19 mm ¾"/19 mm Recessed* Concealed Recessed Concealed Recessed Concealed Recessed Concealed Recessed Concealed inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm Minimum Required 4.0 5.5 5.6 7.2 5.9 7.5 7.7 9.3 15.0 16.6 A Installation Space 101.6 139.7 142.2 182.9 149.9 190.5 195.6 236.2 381.0 421.6 Distance from Top of 0.5 2.0 1.5 1.5 1.5 1.5 3.0 3.0 3.0 3.0 B Typical Ceiling Tile to 12.7 50.8 38.1 38.1 38.1 38.1 76.2 76.2 76.2 76.2 Bottom of Gate * Adjustability will be limited Style ABMM Bracket Stand-off Dimensions 2.22"/ 56 mm 2.94"/ 3.93"/ 75 mm 0.28"/ 100 mm 3.94"/ 7 mm 100 mm 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 15 victaulic.com 4.10 DIMENSIONS Clearances Style AB3 and ABMM Bracket Surface Mount Application with Recessed Sprinkler R C 3¾"/ 95.3 mm B A 23â„8"/60 mm max. hole 2"/51 mm min. hole Hose Clearances inches inches inches inches inches inches inches inches inches inches Dimension mm mm mm mm mm mm mm mm mm mm Wall Thickness 2 4 6 8 10 2 4 6 8 10 "A" 50 100 150 200 250 50 100 150 200 250 Outlet Length 5.75 9 13 5.75 9 13 9 13 13 13 5.75 9 13 5.75 9 13 9 13 13 13 "B" 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 Hose Clearance 11.6 14.8 18.8 9.6 12.8 16.8 10.8 14.8 12.8 10.8 12.6 15.8 19.8 10.6 13.8 17.8 11.8 15.8 13.8 11.8 "C" 294 376 478 243 325 427 275 376 325 275 319 402 503 268 351 452 300 402 351 300 Bend Radius 7 8 "R" 175 200 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 16 victaulic.com 4.11 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with Style 922 threaded outlet Series AH2-CC Braided Hose with Style 922 grooved outlet R See chart R See chart A A See chart See chart Style 922 Threaded Style 922 Mechanical Tee Grooved Outlet Mechanical Tee Outlet 2"/50 mm 2"/50 mm Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm Minimum 3 4 5 6 7 Minimum 3 4 5 6 7 R R Bend Radius 80 100 125 150 175 Bend Radius 80 100 125 150 175 9.4 10.4 11.4 12.4 13.4 7.7 8.7 9.7 10.7 11.7 A Min. A Min. 238 263 289 314 339 197 222 247 273 298 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 17 victaulic.com 4.12 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with female threaded outlet Series AH2-CC Braided Hose with grooved outlet R See chart R See chart A A See chart See chart Female Threaded Weld Outlet No. 142 Grooved Weld Outlet 2"/50 mm 2"/50 mm Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm Minimum 3 4 5 6 7 Minimum 3 4 5 6 7 R R Bend Radius 80 100 125 150 175 Bend Radius 80 100 125 150 175 9.4 10.4 11.4 12.4 13.41 8.1 9.1 10.1 11.1 12.1 A Min. A Min. 239 264 290 315 341 205 231 256 281 307 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 18 victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses with Straight 5.75"/140 mm Reducers Style AB2, AB4, AB5 and AB10 Brackets Hose Reducer UL Equivalent Length of Length Nominal Outlet Size 1"/33.7mm Sch. 40 pipe inches inches feet mm Type DN meters Max Bends 31 1/2 15.0 Straight 3 790 DN15 4.6 31 1/2 16.0 Straight 4 790 DN15 4.9 31 3/4 19.0 Straight 3 790 DN20 5.8 31 3/4 20.0 Straight 4 790 DN20 6.1 36 1/2 18.0 Straight 3 915 DN15 5.5 36 1/2 21.0 Straight 5 915 DN15 6.4 36 3/4 21.0 Straight 3 915 DN20 6.4 36 3/4 23.0 Straight 5 915 DN20 7.0 48 1/2 21.0 Straight 3 1220 DN15 6.4 48 1/2 32.0 Straight 8 1220 DN15 9.8 48 3/4 26.0 Straight 3 1220 DN20 7.9 48 3/4 37.0 Straight 8 1220 DN20 11.3 60 1/2 27.0 Straight 3 1525 DN15 8.2 60 1/2 46.0 Straight 10 1525 DN15 14.0 60 3/4 27.0 Straight 3 1525 DN20 8.2 60 3/4 46.0 Straight 10 1525 DN20 14.0 72 1/2 31.0 Straight 3 1830 DN15 9.4 72 1/2 55.0 Straight 12 1830 DN15 16.8 72 3/4 30.0 Straight 3 1830 DN20 9.1 72 3/4 60.0 Straight 12 1830 DN20 18.3 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 19 victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hose with 90° Low Profile Elbows Style AB11 VicFlex Bracket Hose Reducer UL Equivalent Length of Length Nominal Outlet Size 1"/33.7mm Sch. 40 pipe inches inches feet mm Type DN meters Max Bends 31 1/2 18.0 LP Elbow 3 790 DN15 5.5 31 1/2 24.0 LP Elbow 4 790 DN15 7.3 31 3/4 21.0 LP Elbow 3 790 DN20 6.4 31 3/4 24.0 LP Elbow 4 790 DN20 7.3 36 1/2 19.0 LP Elbow 3 915 DN15 5.8 36 1/2 26.0 LP Elbow 5 915 DN15 7.9 36 3/4 23.0 LP Elbow 3 915 DN20 7.0 36 3/4 28.0 LP Elbow 5 915 DN20 8.5 48 1/2 23.0 LP Elbow 3 1220 DN15 7.0 48 1/2 43.0 LP Elbow 8 1220 DN15 13.1 48 3/4 30.0 LP Elbow 3 1220 DN20 9.1 48 3/4 42.0 LP Elbow 8 1220 DN20 12.8 60 1/2 28.0 LP Elbow 3 1525 DN15 8.5 60 1/2 49.0 LP Elbow 10 1525 DN15 14.9 60 3/4 31.0 LP Elbow 3 1525 DN20 9.4 60 3/4 50.0 LP Elbow 10 1525 DN20 15.2 72 1/2 31.0 LP Elbow 3 1830 DN15 9.4 72 1/2 65.0 LP Elbow 12 1830 DN15 19.8 72 3/4 36.0 LP Elbow 3 1830 DN20 11.0 72 3/4 63.0 LP Elbow 12 1830 DN20 19.2 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 20 victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2"/51 mm center line bend radius Nominal Outlet 1 2 3 4 5 6 7 8 9 10 11 12 Length Size Bend Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends inches inches feet feet feet feet feet feet feet feet feet feet feet feet mm DN meters meters meters meters meters meters meters meters meters meters meters meters 31 1/2 11.0 13.0 15.0 16.0 – – – – – – – – 790 DN15 3.4 4.0 4.6 4.9 31 3/4 12.0 14.0 19.0 20.0 – – – – – – – – 790 DN20 3.7 4.3 5.8 6.1 36 1/2 14.0 16.0 18.0 19.0 21.0 – – – – – – – 915 DN15 4.3 4.9 5.5 5.8 6.4 36 3/4 17.0 19.0 21.0 22.0 23.0 – – – – – – – 915 DN20 5.2 5.8 6.4 6.7 7.0 48 1/2 18.0 19.0 21.0 23.0 25.0 27.0 30.0 32.0 – – – – 1220 DN15 5.5 5.8 6.4 7.0 7.6 8.2 9.1 9.8 48 3/4 21.0 24.0 26.0 28.0 31.0 33.0 35.0 37.0 – – – – 1220 DN20 6.4 7.3 7.9 8.5 9.4 10.1 10.7 11.3 60 1/2 21.0 24.0 27.0 30.0 32.0 35.0 37.0 40.0 43.0 46.0 – – 1525 DN15 6.4 7.3 8.2 9.1 9.8 10.7 11.3 12.2 13.1 14.0 60 3/4 23.0 25.0 27.0 29.0 32.0 34.0 37.0 40.0 43.0 46.0 – – 1525 DN20 7.0 7.6 8.2 8.8 9.8 10.4 11.3 12.2 13.1 14.0 72 1/2 27.0 29.0 31.0 34.0 37.0 40.0 43.0 46.0 48.0 50.0 52.0 55.0 1830 DN15 8.2 8.8 9.4 10.4 11.3 12.2 13.1 14.0 14.6 15.2 15.8 16.8 72 3/4 26.0 28.0 30.0 33.0 37.0 40.0 44.0 48.0 51.0 54.0 57.0 60.0 1830 DN20 7.9 8.5 9.1 10.1 11.3 12.2 13.4 14.6 15.5 16.5 17.4 18.3 NOTES • Values for use with 5.75"/140 mm straight reducers. • The values in this table are provided by the manufacturer for reference only. For friction loss data in accordance with the UL Certification, please refer to pages 19 and 20 of this publication. How to use this Design Guide: • For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends. In this case, the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. • It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 21 victaulic.com 5.1 PERFORMANCE – FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of Length of of 90° Bends Stainless Steel Outlet 1"/33.7 mm at 7"/178 mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters 1/2 13.8 15 4.2 31 5.6 Straight 2 790 8.1 1/2 23.5 15 7.1 90Ëš Elbow 1/2 16.6 15 5.1 36 5.6 Straight 2 915 8.1 1/2 25.6 15 7.8 90Ëš Elbow 1/2 23.4 15 7.1 48 5.6 Straight 3 1220 8.1 1/2 30.7 15 9.3 90Ëš Elbow 1/2 30.2 15 9.2 60 5.6 Straight 4 1525 8.1 1/2 35.9 15 10.9 90Ëš Elbow 1/2 37.0 15 11.3 72 5.6 Straight 4 1830 8.1 1/2 41.1 15 12.5 90Ëš Elbow 3/4 16.8 20 5.1 31 8.0 Straight 2 790 11.5 3/4 16.8 20 5.1 90Ëš Elbow 3/4 20 20 6.0 36 8.0 Straight 2 915 11.5 3/4 19.7 20 6.0 90Ëš Elbow 3/4 27.8 20 8.4 48 8.0 Straight 3 1220 11.5 3/4 26.6 20 8.1 90Ëš Elbow FM NOTES • The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 22 victaulic.com 5.1 PERFORMANCE – FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of Length of of 90° Bends Stainless Steel Outlet 1"/33.7 mm at 7"/178 mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters 3/4 35.7 20 10.9 60 8.0 Straight 4 1525 11.5 3/4 33.6 20 10.2 90Ëš Elbow 3/4 43.5 20 13.2 72 8.0 Straight 4 1830 11.5 3/4 40.6 20 12.2 90Ëš Elbow 3/4 16.5 20 5.0 31 11.2 Straight 2 790 16.1 3/4 17.8 20 5.4 90Ëš Elbow 3/4 19.5 20 5.9 36 11.2 Straight 2 915 16.1 3/4 20.7 20 6.3 90Ëš Elbow 3/4 26.7 20 8.1 48 11.2 Straight 3 1220 16.1 3/4 27.9 20 8.5 90Ëš Elbow 3/4 33.9 20 10.3 60 11.2 Straight 4 1525 16.1 3/4 35 20 10.7 90Ëš Elbow 3/4 41.3 20 12.5 72 11.2 Straight 4 1830 16.1 3/4 42.2 20 12.8 90Ëš Elbow 3/4 14.9 20 4.5 31 14.0 Straight 2 790 20.2 3/4 15.5 20 4.72 90Ëš Elbow FM NOTES • The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 23 victaulic.com 5.1 PERFORMANCE – FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of Length of of 90° Bends Stainless Steel Outlet 1"/33.7 mm at 7"/178 mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters 3/4 19.4 20 5.9 36 14.0 Straight 2 915 20.2 3/4 19.6 20 5.9 90Ëš Elbow 3/4 30.3 20 9.2 48 14.0 Straight 3 1220 20.2 3/4 29.5 20 8.9 90Ëš Elbow 3/4 33.9 20 10.3 60 14.0 Straight 4 1525 20.2 3/4 34.1 20 10.4 90Ëš Elbow 3/4 37.5 20 11.4 72 14.0 Straight 4 1830 20.2 3/4 38.6 20 11.7 90Ëš Elbow FM NOTES • The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 24 victaulic.com 5.2 PERFORMANCE – FRICTION LOSS DATA Series AH2 Braided Hose with 90° Low Profile Elbows Style AB5, AB11, AB12, ABBA and ABMM VicFlex Bracket Maximum Equivalent Number Length of Length of of 90° Bends Stainless Steel Outlet 1"/33.7mm at 7"/178mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches Imperial inches feet mm S.I. mm meters 31 5.6 1/2 13.7 2 790 8.1 15 4.2 36 5.6 1/2 17.0 2 915 8.1 15 5.2 48 5.6 1/2 25.0 3 1220 8.1 15 7.6 60 5.6 1/2 33.0 4 1525 8.1 15 10.1 72 5.6 1/2 41.1 4 1830 8.1 15 12.5 31 8.0 3/4 13.6 2 790 11.5 20 4.14 36 8.0 3/4 16.9 2 915 11.5 20 5.2 48 8.0 3/4 27.8 3 1220 11.5 20 8.5 60 8.0 3/4 32.6 4 1525 11.5 20 9.9 72 8.0 3/4 40.6 4 1830 11.5 20 12.4 31 11.2 3/4 13.7 2 790 16.1 20 4.2 36 11.2 3/4 17.0 2 915 16.1 20 5.2 48 11.2 3/4 24.9 3 1220 16.1 20 7.6 60 11.2 3/4 32.9 4 1525 16.1 20 10.0 72 11.2 3/4 40.9 4 1830 16.1 20 12.5 31 14.0 3/4 13.5 2 790 20.2 20 4.1 36 14.0 3/4 16.8 2 915 20.2 20 5.1 48 14.0 3/4 24.7 3 1220 20.2 20 7.5 60 14.0 3/4 32.7 4 1525 20.2 20 9.9 72 14.0 3/4 40.7 4 1830 20.2 20 12.4 FM NOTES • The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 25 victaulic.com 5.3 PERFORMANCE – FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hose Style AB2, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB11 and AB12 Brackets Equivalent Length of Length of steel pipe according to Stainless Steel Outlet EN 10255 DN 25 Maximum Number Flexible Hose Size (33,7 x 3,25) of 90º Bends at mm DN meters 3"/76.2 mm Bend inches inches feet Radius DN15 790 1/2 5.5 3 31 DN20 18.0 3/4 DN15 915 1/2 6.4 3 36 DN20 21.0 3/4 DN15 1220 1/2 8.5 3 48 DN20 27.9 3/4 DN15 1525 1/2 10.7 4 60 DN20 35.1 3/4 DN15 1830 1/2 12.8 4 72 DN20 42.0 3/4 VdS Ceiling Manufacturers List AB2, AB7, AB10 ,AB11 AB4 AB5, AB8 1. AMF No specific approval 1. Hilti 2. Armstrong 2. Knauf 3. Chicago Metallic 3. Lafarge 4. Dipling 4. Lindner 5. Durlum 5. Rigips 6. Geipel 7. Gema-Armstrong 8. Hilti 9. Knauf 10. Lafarge 11. Linder 12. Odenwald 13. Richter 14. Rigips 15. Rockfon Pagos 16. Suckow & Fischer 17. USG Donn 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 26 victaulic.com 5.3 PERFORMANCE – FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hose Series AH2 Braided Hose Style AB2, AB3, AB4, AB5, AB7, AB8, Style AB2, AB3, AB4, AB5, AB7, AB8, AB10 LPS 1261: Issue 1.2 and AB10 Brackets and AB12 Brackets Cert/LPCB Ref. 104l/01 104l/04 Length of Equivalent Length Maximum Stainless of steel pipe Number of Equivalent Length of Steel according to 90º Bends at Length of 1"/33.7 mm Sch. 40 Pipe Flexible Outlet EN 10255 DN 25 3"/76.2 mm Flexible Hose Size (33,7 x 3,25) Bend Radius Hose Straight Configuration Bend Configuration mm mm inches meters mm meters meters inches type feet inches feet feet 15 mm 1/2 790 Straight 1.8 790 0.87 2.70 2 31 20 mm 6.0 31 2.9 8.9 3/4 Straight 15 mm 1/2 915 Straight 3.6 915 1.00 2.80 3 36 20 mm 11.9 36 3.3 9.2 3/4 Straight 15 mm 1/2 1220 Straight 4.3 1220 2.23 4.66 3 48 20 mm 14.0 48 7.3 15.3 3/4 Straight 15 mm 1/2 1525 Straight 4.1 1525 2.90 6.5 3 60 20 mm 13.6 60 9.5 21.3 3/4 Straight 15 mm 1/2 1830 Straight 5.5 1830 3.31 7.16 3 72 20 mm 18.1 72 10.9 23.5 3/4 Straight CCCF NOTE • Friction loss data is in accordance with GB5135.16 tested at a flow rate of 114 liters per minute (30 gallons per minute). 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 27 victaulic.com 6.0 NOTIFICATIONS WARNING • Read and understand all instructions before attempting to install any Victaulic products. • Always verify that the piping system has been completely depres- surized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. • These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain im- portant information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. WARNING • It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. • The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. • It is the responsibility of the owner of a building or their authorized agent to provide the sprinkler system installer with any knowledge that the water supply might be contaminated with or conducive to the development of micro- biologically influenced corrosion (MIC), including as required by NFPA 13. Failure to identify adverse water quality issues may affect the VicFlex product and void the manufacturer’s warranty. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. Victaulic VicFlex Series AH2 and AH2-CC Flexible Sprinkler Fittings may be painted provided the paint is compatible with stainless steel and zinc-plated carbon steel or ductile iron. Care should be taken to ensure the sprinkler and associated escutcheon or coverplate are not painted. Victaulic VicFlex Series AH2 and AH2-CC penetrating through non-fire rated gypsum wall (drywall) will function as designed, provided the components are installed in accordance with the respective installation instructions referenced in this document. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 28 victaulic.com 7.0 REFERENCE MATERIALS – CHARACTERISTICS VicFlex Maximum Load Values Series AH2 Hose with 24" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m lb N lb/linear ft N/linear m 2.6 31/790 5.2 23 2.6 38 0.8 3 36/915 5.5 25 2.8 40 0.9 4 48/1220 6.3 28 3.1 46 1.2 5 60/1525 7.0 31 3.5 51 1.5 6 72/1830 7.7 34 3.9 57 1.8 Series AH2 Hose with 48" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m lb N lb/linear ft N/linear m 2.6 31/790 6.1 27 1.5 22 0.8 3 36/915 6.4 29 1.6 23 0.9 4 48/1220 7.2 32 1.8 26 1.2 5 60/1525 7.9 35 2.0 29 1.5 6 72/1830 8.7 39 2.2 32 1.8 Total Load is defined as the sum of the weights of the following: • water-filled flexible sprinkler hose with threaded end fittings, including a typical fire sprinkler • bracket assembly (any applicable Victaulic bracket model of the relevant associated size) ASTM C 635: Suspension System Load-Carrying Capabilities (excerpted) Actual Length Min. Allowable Uniform Load Suspension System ft/m lb/linear ft N/linear m Light 5.0 75.7 Direct Hung Intermediate 12.0 181.0 Heavy 16.0 241.7 SUMMARY: All direct-hung suspension system duty classifications per ASTM C 635 are able to withstand the maximum water-filled weight of the VicFlex sprinkler hose and bracket. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 29 victaulic.com 7.0 REFERENCE MATERIALS – CHARACTERISTICS (CONTINUED) Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends 2X 2X Minimum Minimum Minimum bend radius bend radius bend radius OR Minimum OR bend radius 90° Minimum bend radius Minimum Minimum bend radius bend radius Minimum bend radius Minimum bend radius NOTE For out-of-plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. I-VicFlex-AB1-AB2 I-VicFlex-AB3 I-VicFlex-AB4 I-VicFlex-AB5 I-VicFlex-AB7 I-VicFlex-AB12 I-VicFlex-ABBA I-VicFlex-ABMM I-RES User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products for a particular end-use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations. instructions. Nothing in this or any other document, nor any verbal recommendation, Installation advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to I-VICFLEX-AB1-AB2-AB10, I-VICFLEX-AB4, or waive any provision of Victaulic Company's standard conditions of sale, installation I-VICFLEX-AB7, or I-VICFLEX-AB8 for the product you are installing. Handbooks are guide, or this disclaimer. included with each shipment of Victaulic products for complete installation and assembly Intellectual Property Rights data, and are available in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recommendation for the use of such Trademarks material, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right. The terms “Patented†or “Patent Pending†refer to design or utility patents Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 10.85 5839 Rev AL Updated 02/2022 © 2022 Victaulic Company. All rights reserved. victaulic.com 30 SECTION 2 Hangers & Attachments Pipe Hangers & Supports Continuous Threaded Rod Fig. 146 (Formerly Afcon Fig. 650) Size Range: ½" through 1¾" stocked in six, ten, and twelve foot lengths. Other even foot lengths can be furnished to order. Material: Carbon steel or Stainless Steel Gr 304 Threads: National Coarse (USS), rod threaded complete length. Finish: Plain or Zinc Plated (Hot-Dip Galvanized optional) Maximum Temperature: Zinc Plated 450ËšF, Stainless Steel 650° F Approvals: Complies with MSS SP-58. Ordering: Specify rod diameter and length, figure number,name and finish. Length Note: The acceptability of galvanized coatings at temperatures above 450°F is at the discretion of the end user. A Fig. 146: Dimensions (in) • Loads (lbs) • Weight (lbs) Max Load Rod Size A Threads per Inch Weight per Ft. 650Ëš F 1â„ 4 20 240 0.12 3â„ 8 16 730 0.30 1â„ 2 13 1,350 0.53 5â„ 8 11 2,160 0.84 3â„ 4 10 3,230 1.20 7â„ 8 9 4,480 1.70 1 8 5,900 2.30 11â„ 4 7 9,500 3.60 11â„ 2 6 13,800 5.10 PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SS-1.18 page 1 SS-SUB-146-v01 20220427 115 STANDARD DUTY LOOP HANGER The 115 Standard Duty Loop Hanger is ideal for suspending stationary, non-insulated pipe lines, including CPVC pipes, in fire sprinkler systems. A knurled insert nut helps simplify vertical adjustments and flared edges on the base (1/2" to 4" sizes) help protect pipes from coming into contact with any sharp edges of the hanger. CERTIFICATIONS FEATURES Flared edges help prevent any sharp surfaces from coming into contact with the pipe (1/2" to 4" sizes) Retained insert nut helps ensure the loop hanger and insert nut stay together Recommended for the suspension of stationary non-insulated pipe lines Manufactured to use the minimum rod size permitted by NFPA® for fire sprinkler piping Conforms with Federal Specification WW-H-171 (Type 10), Manufacturers Standardization Society (MSS) SP-58 (Type 10) SPECIFICATIONS Finish: Pregalvanized Material: Steel Table 1/2 Outer Catalog Rod Size Pipe Size Diameter A B C Number (RS) (OD) 1150050EG 1/2" 0.84" 3/8" 2 13/16" 1 1/8" 1" 1150075EG 3/4" 1.05" 3/8" 3" 1 3/16" 15/16" 1150100EG 1" 1.31" 3/8" 3 1/4" 1 3/8" 15/16" 1150125EG 1 1/4" 1.66" 3/8" 3 9/16" 1 1/2" 15/16" Outer Catalog Pipe Size Diameter Rod Size(RS) A B C Number (OD) 1150150EG 1 1/2" 1.9" 3/8" 3 13/16" 1 5/8" 15/16" 1150200EG 2" 2 3/8" 3/8" 4 1/4" 1 7/8" 15/16" 1150250EG 2 1/2" 2 7/8" 3/8" 5 15/16" 3 7/16" 2" 1150300EG 3" 3 1/2" 3/8" 6 9/16" 3 1/2" 1 15/16" 1150350EG 3 1/2" 4" 3/8" 7 1/16" 3 3/4" 1 15/16" 1150400EG 4" 4 1/2" 3/8" 7 9/16" 4" 1 15/16" 1150500EG 5" 5 9/16" 1/2" 9 13/16" 4 3/4" 2 1/4" 1150600EG 6" 6 5/8" 1/2" 11 5/16" 6 5/16" 3 5/16" 1150800EG 8" 8 5/8" 1/2" 12 7/8" 6 7/8" 2 7/8" Table 2/2 Catalog Number Static Load (F) Certifications 1150050EG 300lb cUL, UL cUL, FM Approved, Pipe Hanger 1150075EG 300lb Components, UL cUL, FM Approved, Pipe Hanger 1150100EG 300lb Components, UL cUL, FM Approved, Pipe Hanger 1150125EG 300lb Components, UL cUL, FM Approved, Pipe Hanger 1150150EG 300lb Components, UL cUL, FM Approved, Pipe Hanger 1150200EG 300lb Components, UL cUL, FM Approved, Pipe Hanger 1150250EG 525lb Components, UL cUL, FM Approved, Pipe Hanger 1150300EG 525lb Components, UL cUL, FM Approved, Pipe Hanger 1150350EG 585lb Components, UL cUL, FM Approved, Pipe Hanger 1150400EG 650lb Components, UL cUL, FM Approved, Pipe Hanger 1150500EG 1000lb Components, UL cUL, FM Approved, Pipe Hanger 1150600EG 1000lb Components, UL cUL, FM Approved, Pipe Hanger 1150800EG 1000lb Components, UL 2 DIAGRAMS WARNING nVent products shall be installed and used only as indicated in nVent's product instruction sheets and training materials. Instruction sheets are available at www.nvent.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. North America Europe Europe APAC +1.800.753.9221 Netherlands: Germany: Shanghai: Option 1 – Customer Care +31 800-0200135 800 1890272 + 86 21 2412 1618/19 Option 2 – Technical Support France: Other Countries: Sydney: +33 800 901 793 +31 13 5835404 +61 2 9751 8500 Our powerful portfolio of brands: nVent.com CADDY ERICO HOFFMAN RAYCHEM SCHROFF TRACER 3 © 2024 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice. SECTION 3 Fire Sprinklers Bulletin 074 October 2022 F1FR56 Series Quick Response Sprinklers K-factor 5.6 (80) Features • Standard coverage quick-response sprinklers • Upright, pendent, horizontal sidewall, and vertical sidewall deflectors • Low profile, compact design • Available in a wide variety of finishes Product Description Model F1FR56 Pendent Model F1FR56 Upright Reliable Model F1FR56 series sprinklers are quick-response standard spray automatic fire sprinklers utilizing a sensitive 3.0 mm glass bulb thermal element. Pendent and horizontal sidewall sprinklers may be installed exposed or surface mounted using escutcheons such as the Reliable Models B, C, or HB (reference Technical Bulletin 204). When installed recessed or concealed, the Model F1FR56 series sprinklers are specifically listed with and may only be installed with listed Reliable escutcheons and cover plates. Refer to the Model F1FR56 Vertical Sidewall Model F1FR56 technical information on the following pages for specific listings Horizontal Sidewall for recessed and concealed installations and refer to Figures 5 and 6 for dimensional information. Note: Not all versions of the product are shown. When fitted with an approved water shield, these sprinklers may considered intermediate sprinklers for use in racks, below grated walkways, and other areas where intermediate level sprinklers are required. Note: This bulletin may contain information on New and Legacy sprinklers that reflects a dimensional change only. Sprinkler Iden- Table A provides a summary of the approvals and availability of tification Number (SIN), application, performance, and listings/ specific Model F1FR series sprinkler configurations. Additional approval are not otherwise affected. Sprinklers with New frames technical information for each sprinkler model is provided on the will include the suffix “N†in the order. following pages. F1FR Series Sprinklers Summary Table A Sprinkler Sprinkler K-Factor gpm/psi1/2 Orientation Listings & Approvals Max. Working Pressure Identification Model (lpm/bar1/2) psi (bar) Number (SIN) Upright cULus, FM, LPCB, VdS, 175 (12) RA1425 Intermediate Upright EC, WM 250 (17) (cULus only) cULus, FM, LPCB, VdS, 175 (12) Pendent RA1414 EC, WM 250 (17) (cULus only) 175 (12) F1FR56 5.6 (80) Concealed Pendent cULus, VdS, EC, WM RA1414 250 (17) (cULus only) 175 (12) Horizontal Sidewall cULus, FM RA1435 250 (17) (cULus only) Vertical Sidewall cULus, FM, LPCB 175 (12) RA1485 www.reliablesprinkler.com Model F1FR56 Upright Sprinkler SIN RA1425 Technical Specifications Guards & Shields (New Frames) Style: Upright, Intermediate Upright Factory Water Shield (cULus, FM) Threads: 1/2†NPT or ISO 7-R1/2 F-1 Guard (cULus, FM) Nominal K-Factor: 5.6 (80 metric) F-3 Guard with Shield (cULus, FM) Max. Working Pressure: 175 psi (12 bar) Guards and Shields (Legacy Frames) 250 psi (17 bar) (cULus only) Factory Water Shield C-1 Guard (FM) Material Specifications C-3 Guard with Shield (cULus, FM) Thermal Sensor: 3 mm Glass Bulb D-1 Guard (cULus) Sprinkler Frame: Brass Alloy D-3 Guard with Shield (cULus) Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Sprinkler Wrench Load Screw: Copper Alloy Model W2 Deflector: Brass Alloy Model J (New frame with guard installed) Model JD (Legacy frame with guard Sprinkler Finishes installed) (See Table B) Listings and Approvals Sensitivity cULus Listed Quick response FM Approved LPCB Temperature Ratings VdS 135°F (57°C) EC 155°F (68°C) WM 175°F (79°C) 200°F (93°C) 286°F (141°C) Model F1FR56 Upright Sprinkler Components and Dimensions Figure 1 3 1/4" [83mm] 1 3/8" [33mm] Load Screw Deflector Glass Bulb (3 mm) F1FR_HALF_UPR_INT 2 1/4" [58mm] Wrench Flat Cap/Seal Assembly Threads Shown with Optional Factory Installed Water Shield ( Intermediate Upright) Bulletin 074 Page 2 of 9 October 2022 www.reliablesprinkler.com Model F1FR56 Pendent Sprinkler SIN RA1414 Technical Specifications Recessed Escutcheons Style: Model F1 (cULus, LPCB, VdS, CE, WM) Pendent Model F2 (cULus, FM, LPCB, VdS, CE, Recessed Pendent WM) Concealed Pendent Model FP (cULus, VdS, CE, WM) Threads: 1/2†NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Cover Plate Max. Working Pressure: Model CCP (cULus, VdS(2), CE(2)) 175 psi (12 bar) 250 psi (17 bar) (cULus only) Guards & Shields (New Frames)(3) F-1 Guard (FM) Material Specifications F-5 Guard/Shield Kit (FM) Thermal Sensor: 3 mm Glass Bulb F-7 Guard (cULus) Sprinkler Frame: Brass Alloy F-8 Guard/Shield Kit (cULus) Cap: Bronze Alloy S-1 Shield (cULus, FM) Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Guards & Shields (Legacy Frames)(3) Deflector: Brass Alloy C-1 Guard (FM) C-5 Guard/Shield Kit (FM) Sprinkler Finishes D-1 Guard (cULus, FM) (See Table B) D-4 Guard/Shield Kit (FM) Sensitivity D-5 Guard/Shield Kit (cULus, FM) Quick response S-1 Shield (cULus, FM) Temperature Ratings(1) Sprinkler Wrenches 135°F (57°C) Model W2 (pendent) 155°F (68°C) Model W4 (recessed or concealed) 175°F (79°C) Model J (New frame with guard installed) 200°F (93°C) Model JD (Legacy frame with guard 286°F (141°C) installed) Listings and Approvals(4) cULus Listed FM Approved LPCB VdS EC WM Notes: 1. 286°F (141°C) temperature rated sprinkler not listed for recessed or concealed use. 2. VdS and CE approval for CCP concealed use is for 155°C (68°C) sprinkler ONLY. 3. Not suitable for recessed or concealed pendent installations. 4. When used surface mounted or exposed. See Recessed Escutcheon and Cover Plate section for specific approvals when installed recessed or concealed. Model F1FR56 Pendent Sprinkler Components and Dimensions Figure 2 3 1/4" [83mm] Threads F1FR_HALF_PEND_INT Wrench Flat 2 1/4" [57mm] Cap/Seal Assembly Glass Bulb (3 mm) Deflector Load Screw 1" [25mm] Shown with Optional S-1 Water Shield (Ordered Separately) Note: Please refer to Figure 8 for recessed and concealed installation. Bulletin 074 Page 3 of 9 October 2022 www.reliablesprinkler.com Model F1FR56 Horizontal Sidewall Sprinkler SIN RA1435 (2) Technical Specifications Recessed Escutcheons Style: Model F1 (cULus) Horizontal Sidewall Model F2 (cULus, FM) Recessed Horizontal Sidewall Model FP (cULus) Threads: 1/2†NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Guards & Shields (New Frames)(3) F-4 Guard (FM) Max. Working Pressure: F-7 Guard (cULus) 175 psi (12 bar) 250 psi (17 bar) (cULus only) Guards & Shields (Legacy Frames)(3) Material Specifications C1 Guard (FM) Thermal Sensor: 3 mm Glass Bulb D1 Guard (cULus) Sprinkler Frame: Brass Alloy Sprinkler Wrenches Cap: Bronze Alloy Model W2 (non-recessed) Sealing Washer: Nickel with PTFE Model W4 (recessed) Load Screw: Copper Alloy Model J (New frame with guard installed) Deflector: Brass Alloy Model JD (Legacy frame with guard installed) Sprinkler Finishes (See Table B) Listings and Approvals cULus Listed(4) Sensitivity Quick response FM Approved(5) Temperature Ratings (1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Notes: 1. 286°F (141°C) temperature rated sprinkler not listed for recessed use. 2. FM approved recessed installation when used with Model F2 escutcheon ONLY. 3. Not suitable for recessed horizontal sidewall installations. 4. cULus Listed for Light and Ordinary Hazard when installed exposed or surface mounted. Listed for Light Hazard ONLY when installed recessed. 5. FM Approved for Light Hazard ONLY. Model F1FR56 Horizontal Sidewall Sprinkler Components and Dimensions Figure 3 1 1/8" [28mm] Deflector Load Screw Frame Glass Bulb 2 3/4" [70mm] (3 mm) F1FR_HALF_HSW Wrench Flat Cap/Seal Assembly Threads Note: Please refer to Figure 9 for recessed installation. Bulletin 074 Page 4 of 9 October 2022 www.reliablesprinkler.com Model F1FR56 Vertical Sidewall Sprinkler SIN RA1485 Technical Specifications Guards & Shields (New Frames) Style: F-2 Guard (FM) Upright Vertical Sidewall Guards & Shields (Legacy Frames) Pendent Vertical Sidewall C1 Guard (FM) Threads: 1/2†NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Sprinkler Wrenches Max. Working Pressure: 175 psi (12 bar) Model W2 Model J (New frame with guard installed) Material Specifications Model JD (Legacy frame with guard Thermal Sensor: 3 mm Glass Bulb installed) Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Listings and Approvals(1) cULus Listed Load Screw: Copper Alloy FM Approved Deflector: Brass Alloy (2) LPCB Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Notes: 1. Listed and approved for Light Hazard ONLY. 2. LPCB approved for use in pendent position ONLY. Model F1FR56 Vertical Sprinkler Components and Dimensions Figure 4 Deflector Load Screw 1 1/2" [38mm] Frame Glass Bulb (3 mm) F1FR_HALF_VSW 2 1/4" [57mm] Wrench Flat Cap/Seal Assembly Threads Bulletin 074 Page 5 of 9 October 2022 www.reliablesprinkler.com Recessed and Concealed Installation: Pendent Sprinklers Figure 5 2-1/4" 2-1/4" (57 mm) Dia. (57 mm) Dia. Hole in Ceiling Hole in Ceiling 1-15/16" 1-15/16" (49 mm) Dia. (49 mm) Dia. Reducing Reducing Fitting Fitting Face of Fitting Face of Fitting to Face of Ceiling to Face of Ceiling 1-1/8" (29 mm) at 7/8" (22 mm) at Max. Recess Max. Recess 3/8" (10 mm) at 3/8" (10 mm) at Min. Recess Min. Recess 1-3/4" 1-3/4" (44 mm) 1" (44 mm) 1-1/4" (25 mm) (32 mm) Minimum Maximum Minimum Maximum Recess 2-7/8" (72 mm) Dia. Recess Recess 2-7/8" (72 mm) Dia. Recess Models F1 & F1FR Pendent Sprinkler Models F1 & F1FR Pendent Sprinkler with Model F1 Recessed Escutcheon with Model F2 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment 1/2" (13mm) Nominal Adjustment F1_REC_PEND_CCP 2-1/2" 2-1/2" (64 mm) Dia. (64 mm) Dia. Hole in Ceiling Hole in Ceiling 2-5/16" 2-5/16" (59 mm) Dia. (59 mm) Dia. Reducing Reducing Fitting Fitting Face of Fitting Face of Fitting to Face of Ceiling to Face of Ceiling Vented Cup Vented Cup 1-1/2" (38 mm) at 1-1/2" (38 mm) at Max. Recess Max. Recess 1" (25 mm) at 1" (25 mm) at Min. Recess Min. Recess 1" 1" (25 mm) 1/2" (25 mm) 1/2" (12 mm) (12 mm) Minimum Minimum 3-3/16" (78 mm) Dia. Recess Maximum Recess Maximum Recess 3-5/16" (84 mm) Dia. Recess Models F1 & F1FR Pendent Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Model F1FR56 CCP Conical Concealed Sprinkler 1/2" (13mm) Nominal Adjustment Note: Model FP recessed assemblies may not be used where the (Nominal Cover Plate Projection is 1" (25 mm)) pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model FP cup Note: Model CCP concealed assemblies may not be used where are unobstructed following installation. the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model CCP cup are unobstructed following installation. FP Escutcheon F1 Escutcheon CCP Cover Plate (F2 Similar) Bulletin 074 Page 6 of 9 October 2022 www.reliablesprinkler.com Recessed Installation: Horizontal Sidewall Sprinklers Figure 6 1/2" (12 mm) Reducing +/- 3/8" (10 mm) 1-3/8" (35 mm) Maximum Recess Fitting Face of fitting to face of wall 4" - 12" (102 mm - 305 mm) Deflector to ceiling 2-1/4" 1-15/16" 2-7/8" (57 mm) (49 mm) (73 mm) Dia. Dia. Dia. Hole 9/16" [14mm] F1 Recessed escutcheon 3/4" (19 mm) Adjustment 2 1/8" (54 mm) Minimum Recess Model F1FR Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment F1FR_REC_HSW 3/8" (16 mm) Reducing +/- 1/4" (6 mm) 1-5/8" (42 mm) Maximum Recess Fitting Face of fitting to face of wall 4" - 12" (102 mm - 305 mm) Deflector to ceiling 2-1/4" 1-15/16" 2-7/8" (57 mm) (49 mm) (73 mm) Dia. DIA. Dia. Hole 9/16" [14mm] F2 Recessed escutcheon 1/2" (13 mm) Adjustment 2-1/8" (54 mm) Minimum Recess Model F1FR Horizontal Sidewall Sprinkler with Model F2 Recessed Escutcheon 1/2" (13mm) Nominal Adjustment 1-1/4" (32 mm) Reducing +/- 1/4" (6 mm) 7/8" (22 mm) Maximum Recess Fitting Face of fitting to face of wall 4" - 12" (102 mm - 305 mm) Deflector to ceiling 2-5/8" 2-5/16" 3-1/4" (67 mm) (58 mm) (83 mm) Dia Dia. Dia. Hole. 9/16" [14mm] Vented Cup 1-3/8" (35 mm) Minimum Recess Model F1FR Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Note: Model FP recessed assemblies may not be used where the pressure in the space behind the sprinkler is positive with respect to the space in the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. Bulletin 074 Page 7 of 9 October 2022 www.reliablesprinkler.com Wrenches Model W2 (upright, pendent) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed, similar but with zinc finish) Model W4 (recessed, concealed pendent) Finishes(1) Table B Standard Finishes Special Application Finishes F1, F2 and FP(2) CCP Cover F1, F2 and FP(2) Sprinkler Sprinkler CCP Cover Plate(2) Escutcheons Plate(2) Escutcheons Bronze Brass Chrome Electroless Nickel PTFE(3)(4) Bright Brass Bright Brass Chrome Chrome White Paint Bright Brass(5) Satin Chrome Satin Chrome White Polyester(3) White Polyester Satin Chrome Custom Color Polyester Custom Color Paint Custom Color Polyester(3) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Model FP escutcheons and Model CCP sprinklers utilize a galvanized steel cup with a finished trim ring or cover plate. 3. cULus Listed as corrosion resistant. 4. FM Approved as corrosion resistant. 5. For 200°F (93°C) maximum temperature rated sprinklers only. Installation Maintenance Model F1FR Series sprinklers must be installed in accordance with Reliable Model F1FR series sprinklers should be inspected and NFPA13 and the requirements of all applicable authorities having the sprinkler system maintained in accordance with NFPA 25, as jurisdiction. Model F1FR Series sprinklers must be installed with well as the requirements of any Authorities Having Jurisdiction. the Reliable sprinkler installation wrench identified in this Bulletin. Prior to installation, sprinklers should remain in the original Any other wrench may damage the sprinkler. The Models W2 and cartons and packaging until used. This will minimize the potential W4 wrenches have two sets of jaws. Use the smallest set of jaws for damage to sprinklers that could cause improper operation or that fit on the wrench flats of the sprinkler. A leak tight sprinkler non-operation. joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 Do not clean sprinklers with soap and water, ammonia liquid or N.m). Do not tighten sprinklers over the maximum recommended any other cleaning fluids. Remove dust by gentle vacuuming installation torque. Exceeding the maximum recommended without touching the sprinkler. installation torque may cause leakage or impairment of the sprinkler. Replace any sprinkler which has been painted (other than factory applied). A stock of spare sprinklers should be maintained to Glass bulb sprinklers have orange bulb protectors or protective allow quick replacement of damaged or operated sprinklers. caps to minimize bulb damage during shipping, handling and Failure to properly maintain sprinklers may result in inadvertent installation. Reliable sprinkler installation wrenches are designed operation or non-operation during a fire event. to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Bulletin 074 Page 8 of 9 October 2022 www.reliablesprinkler.com Guarantee For the guarantee, terms, and conditions, visit www. reliablesprinkler.com. Ordering Information Specify the following when ordering: Model • F1FR56 Deflector/Orientation • Upright • Intermediate Upright • Pendent • CCP Concealed Pendent • Horizontal Sidewall • Vertical Sidewall Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table B Recessed Escutcheon(1)(2) • F1 • F2 • FP Escutcheon Finish • See Table B CCP Cover Plate Temperature Rating • 135°F (57°C) [For use with 135°F (57°C) and 155°F (68°C) sprinklers.] • 165°F (74°C) [For use with 175°F (79°C) and 200°F (93°C) sprinklers.] CCP Cover Plate Finish • See Table B Sprinkler Wrench • Model W2 • Model W4 (recessed, concealed) • Model J (New frame with guard installed) • Model JD (Legacy frame with guard installed) Notes: 1. 286°F (141°C) sprinklers are not listed to be used recessed or concealed. 2. For FM, recessed sprinklers must use the Model F2 escutcheon. P/N 9999970623 Bulletin 074 Page 9 of 9 October 2022 www.reliablesprinkler.com SECTION 4 Miscellaneous data sheet PTFE THREAD SEAL TAPE (INDUSTRIAL) Meets MIL Spec T-27730A •For all industrial applications. •Made from 100% virgin PTFE. •No pigments, no additives. •Exceeds MILSpec T-27730A. •Temperature range of -450F to +550F. •VOC’s (Volatile Organic Compounds): Minimal. 1.5% or less •May be used on all applicationsincluding water, oil, chemical, medical, and food processing where non-contamination standards are high. 60-10-260 1/2†x 260†STANDARD 0.4 DENSITY INDUSTRIAL GRADE 60-10-262 1/2†x 520†STANDARD 0.4 DENSITY INDUSTRIAL GRADE 60-10-264 1/2†x 1296†STANDARD 0.4 DENSITY INDUSTRIAL GRADE 60-10-262 3/4†x 260†STANDARD 0.4 DENSITY INDUSTRIAL GRADE 60-10-267 3/4†x 520†STANDARD 0.4 DENSITY INDUSTRIAL GRADE 60-10-269 3/4†x 1296†STANDARD 0.4 DENSITY INDUSTRIAL GRADE 60-10-270 1†x 260†STANDARD 0.4 DENSITY INDUSTRIAL GRADE 60-10-271 1†x 520†STANDARD 0.4 DENSITY INDUSTRIAL GRADE 60-10-272 1†x 1296†STANDARD 0.4 DENSITY INDUSTRIAL GRADE The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM TUF-GLIDE Thread Sealant with PTFE Tuf-Glide® is the #1 selling PTFE paste in the fire sprinkler industry. It has replaced it’s competitors as the pipefitters choice. APPLICATIONS: Tuf-Glide may be used on steel, aluminum, brass, copper, iron, reinforced fiberglass, CPVC, PVC and ABS threaded connections. Not for use with Stainless Steel Pipe. Tuf-Glide thread sealant is a non hardening, safe to use sealant containing PTFE for sealing and protecting threaded connections. Its low coefficient of friction allows tight makeup with low torque and breaks out easily without damaging threads. Tuf-Glide contains no lead or other harmful metals and is perfectly safe for use on potable water lines. Contains no silicone. NOT FOR USE ON OXYGEN LINES. Tuf-Glide is recommended for threaded pipe carrying: Acids, Dilute Helium Gases Air Hydraulic OIl Ammonia Inert Gases FBCâ„¢ System Compatible indicates that this product has been Aliphatic Solvents Kerosene tested, and is monitored on an ongoing basis, to Brine LP Gases assure its chemical compatibility with FlowGuard Gold®, CO2 Mineral Oils BlazeMaster® and Corzan® piping systems and products made Caustic, Dilute Natural Gas with TempRite® Technology.†Cold Tar Naphtha Nitrogen, Gaseous “The FBC System Compatible Logo, FBCâ„¢, FlowGuard Gold®, Cutting Oils Petroleum Solvents BlazeMaster®, Corzan®, and TempRite® are trademarks of Lubrizol Advanced Materials, Inc. or its affiliates. Fatty Acids Steam Heating Oils Vegetable Oils Freon Water Service Rating: -35° F (-37° C) to 500° F (260° C) Tuf-Glide is listed under the Uniform Plumbing Code (IAPMO), Pressures: to 10,000 psi for liquids, 2,000 psi for gases File No. 1282. Shelf Life: Indefinite Conforms to Federal Specification TT-S-1732 and the require- V.O.C. Content: None ments Fluid Type: Synthetic of British Standard 6920: Parts 1 & 2. Color/Appearance: White Grainy Paste TFW is recommended for Plumbing, HVAC, Industrial Piping, Dropping Point: (ASTM D-566) Not Applicable Chemical Processing Plants, Manufacturing Plants, Gas Specific Gravity: 1.20 Utilities and Fire Sprinkler Piping. Meets U.S. Federal Density (lb/gal): 10.0 Specification TT-S-1732. Oil Separation: <5.0 WT. % LOSS @ 212°F (100°C) VOC Content: Zero Grams per Liter Flash Point: (ASTM D-92) >350°F (177°C) ITEM # DESCRIPTION Nonvolatile Content: 100% 1010005 1/2 PINT with BRUSHTOP Viscosity, Brookfield (ASTM D-2196) 1010006 1 PINT with BRUSHTOP #7 Spindle, 5 rpm @ 77°F (25°C) 160,000-260,000 cps 1010007 1 QUART FLAT TOP Brushable To: 0°F (-18°C) 1010008 1 QUART with BRUSHTOP Copper Strip Corrosion: 1A 1010009 1 GALLON PAIL (ASTM D-4048) 1010010 5 GALLON PAIL 1010011 55 GALLON DRUM System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com Updated 4/15/2024 TUF-GLIDE Thread Sealant with PTFE California Proposition 65 requirements are that any material produced after October 31st be labeled with the statement below. The only product considered hazardous in ARGCO TUF-GLIDE is Titanium dioxide which is still food grade allowable. Additionally titanium dioxide is only a respirable cancer substance when in a submicron size. Since it is encapsulated in a paste and greater than 1 micron particle size for the largest percentage it is debatable it even needs to be reported as there is no exposure mode. WARNING: This product can expose you to Titanium dioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov. Below is the formula chemical list for ARGCO TUFGLIDE with CAS Numbers. INGREDIENT CAS # Polybutenes 9003-29-6 Calcium sulfonate 61789-86-4 Potassium aluminum silicate 12001-26-2 Kaolin Clay 1332-58-7 Polyethylene 9002-88-4 Talc 14807-96-6 PTFE 9002-84-0 Titanium dioxide (1.2%) 13463-67-7 Organophyllic clay 68953-58-2 TUF-GLIDE DOES NOT INCLUDE ASBESTOS System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com Updated 4/15/2024 Fire Sprinkler Accessories ThreadFit® CLEAR Thread Cutting Oil Fig. 03-16A Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote Caution: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See SDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don’t pollute. Conserve our resources-Please recycle this container. Description See Safety Data Sheet for additional safety and ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light disposal information at www.fppi.com colored cutting oil for all types of ferrous metal. It’s special combination of anti-wear and This product is registered with CHEMTREC, anti-weld additives provides all the necessary lubricity and cooling modern pipe threading a 24-hour emergency hotline. They may be reached at 1 800 424-9300. operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear’s low smoke/ low odor formulation makes it ideal for use in high speed threading applications. Features FBCâ„¢ System Compatible Spears® Compatible indicates • Heavy Duty Cutting Oil • Improved Surface Finish indicates that this product has that ThreadFit® CLEAR Thread • Excellent Tool Life • Low Odor been tested, and is monitored Cutting Oil has been tested by on an ongoing basis, to assure Spears® Manufacturing to be • Chlorine Free • Low Smoke its chemical compatibility with compatible with Flameguard® • All types of ferrous metal or pipe FlowGuard Gold®, BlazeMaster® pipe and futtings. and Corzan® pipe fittings. FBCâ„¢, Installation FlowGuard Gold®, BlazeMaster® and Corzan® are licensed trademarks of The Lubrizol ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according Corporation or its affiliates. to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-04.22 page 1 FP-SUB-03-16A-v01 20220413 SPRINKLER LEGEND INSTALLER NOTES SYMBOL LEGEND SCOPE OF WORK 01 - ALL ARM OVERS 1'-0" OR LONGER REQUIRE HANGER. Symbol MANU. SIN MODEL K-FACTOR TYPE THREAD RESP FINISH TEMP NOTE QTY X RED HAWK FIRE PROTECTION, LLC. (RHFP) TO ADD AND RELOCATE Reliable RA1414 F1FR56 5.6 Pendent ½ Quick Chrome 155°F 4 02 - ALL NEW SPRINKLERS REQUIRED TO BE CENTERED OR QUARTER EXISTING SPRINKLER PIPING WITH LABEL SPRINKLERS AS REQUIRED FOR NEW WALLS AND CEILINGS AS REQUIRED Total = 4 POINTED IN CEILING TILE FOR PROPOSED TENANT IMPROVEMENT. X NEW WET STEEL SPRINKLER PIPE WITH LABEL 03 - ALL FLEX DROPS TO BE 48" UNO X-X SPRINKLER CHANGES WILL NOT REQUIRE MODIFICATIONS TO EXISTING MAINS. 04 - BRANCHLINE RESTAINTS TO BE INSTALLED AT LAST HANGER AND PIPE HANGER EVERY 41'-0 TENANT IMPROVEMENT DOES NOT CHANGE EXISTING SYSTEMS DESIGN HAZARD CLASSIFICATION. GROOVED RIGID COUPLING 05 - TYPICAL HANGER TO BE HILTI HDI-P OR HILTI KH-EZ-I. SPRINKLER MODIFICATIONS TO MATCH EXISTING SPRINKLER SYSTEMS PIPE 06 - BRACE'S TO BE INSTALLED PER PLAN WITHIN 2-0 OF SHOWN LOCATION. SIZING, AND SPRINKLER K-FACTOR. DESIGN CRITERIA ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED BY OTHERS AT A MINIMUM 40°F TO PREVENT FREEZING. PER NFPA 13 (2019), CITY OF ARLINGTON, AND PROJECT SPECIFICATION EXCLUSIONS PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT NICET Stamp OFFICE WET SYSTEM ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATER LIGHT HAZARD FLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES DESIGN DENSITY: .10 GPM / 1500 SQ. FT. CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES Travis Clifton Kinne 0835-1021-C Level 3 ALL UNDERGROUND WORK INCLUDING BUT NOT LIMITED TO: BACKFILL, Red Hawk Fire Protection, LLC SELECT FILL, BREAKING PATCHING, SAW CUTTING, LAWN REPAIR, REDHAHF901QP LANDSCAPING, TREE REMOVAL, STERILIZATION, DEVELOPMENT FEES AND CITY CONNECTION. 01/23/2025 RELOCATING OF ANY SPRINKLER COMPONENTS FOR OTHER TRADES. Approvals Required CITY OF ARLINGTON OWNER / ARCHITECT GENERAL NOTES 01 - SPRINKLER SYSTEM DESIGN PER NFPA #13 (2019), AND AUTHORITY Revisions HAVING JURISDICTION (CITY OF ARLINGTON). 02 - ALL MATERIALS SHALL BE NEW AND UL AND/OR FM APPROVED. 03 - FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH NFPA #13 AND AUTHORITY HAVING JURISDICTION. 04 - IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGH OUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE, AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. 05 - FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF. 06 - ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING, OR PATCHING TO BE BY OTHERS. 07 - 1" - 1¼" PIPE TO BE THREADED SCHD 40 STEEL WITH THREADED DUCTILE IRON FITTINGS UNO. 08 - ALL PENDENT HEADS TO BE CENTERED IN ONE DIRECTION OF CEILING TILES. UNLESS SPACING DOES NOT ALLOW. 09 - ALL FLEXIBLE DROP FITTINGS TO BE 72" UNO. 10 - ALL FLEXIBLE FITTINGS TO BE INSTALLED PER MANUFACTURES LISTINGS NOT TO EXCEED MAXIMUM ALLOWED BENDS AND BEND RADIUS. 11 - TYPICAL STEEL HANGER TO BE RING HANGER ATTACHED WITH HILTI HDI-P TZ UNO. 12 - VICINITY MAP13 - 14 - 15 - 16 - Contract With: FABER CONSTRUCTION SITE 6951 HANNEGAN ROAD LYNDEN, WA 98264 PM: ADOLFO FLORINDO Phone: 360-354-0335 Email: adolfo@faberconstruction.com Contract Name: E F G H J K SNOPUD PWC-NCCO 1 1 17601 59TH AVE NE ARLINGTON, WA 98223 Drawing Title FIRE SPRINKLER PLAN - LEVEL 1 TI 2 2 1½0-6 Key Plan 1½ 11-1½ OFFICE/CONF ROOM 119 CONF ROOM 115 10-0 10-0 AREA OF WORK 1½ X 1 MT 1½ 1½ CREW ROOM 1½ 121 1½ 10-0 2-11½ 1½ 1½ OPEN OFFICE FLEX/ ADMIN/FOREMEN/ 1½ 1½ 1½ X 1 MT 3 SERVICEMEN 1½ 3 118 AREA NOT IN SCOPE 10-0 AREA NOT IN SCOPE 1½ 6-2½ 1½0-6 1½ 5-4½ OFFICE/CONF ROOM 116 10-0 1½ Date: January 22, 2025 1½ 6-7½ 1½ Job Number: 60181 1½ Designer: AUSTIN WORKING 4 1½ 1½ 1½1-0 1½ 4 1½ 4-2 1½ 1½ 1½ ENTRY VEST Building Permit: 1½ 2-9 122 DN P 1-2½ 9-0 9-0 10-0 DN 1½ 1½ 1½ 1½ 1½ 1½ Drawing No. 1½ 4-4 1½ 7-7½ 2-0 3-6 2-10 4-6½ 0-6 6-11½ FIRE SPRINKLER PLAN - LEVEL 1 TI FP 1 OF 1 0 2' 4' 8' 16' SCALE: 1/8"=1'-0" E F G H J K CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 17601 59TH AVE NE Permit #: 6329 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 31052200400200 DATE OF ISSUANCE. Scope of Work: To add/relocate 4 sprinklers to accommodate newly added walls and Valuation: 4980.00 lights. OWNER APPLICANT CONTRACTOR PUBLIC UTILITY DISTRICT NO 1 Red Hawk Fire Protection, LLC Red Hawk Fire Protection, LLC PO BOX 1107 801 Valley Ave NW, Suite D 801 Valley Ave NE EVERETT, WA 98206 Puyallup, WA 98371 Puyallup, WA 98371 2538409900 253-840-9900 LIC: 603 058 495 EXP: 10/31/2025 LIC: REDHAHF901QP EXP: 11/17/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC #: EXP: LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE SPRINKLER CODE YEAR: 2021 STORIES: 1 CONST. TYPE: lB DWELLING UNITS: OCC GROUP: B; Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 02/24/2025 Applicant Signature Date Building Official Date CONDITIONS ADHERE TO THE APPROVED PLANS. APPROVED JOB COPY SHALL BE ONSITE FOR INSPECTIONS. CALL FOR INSPECTIONS. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 04/21/2025 Web Only - Fire System Plan Review $200.00 04/21/2025 Credit Card Service $6.00 04/21/2025 Fire Sprinkler System $125.00 04/21/2025 Processing/Technology $25.00 04/21/2025 Credit Card Service $4.50 Total Due: $360.50 Total Payment: $360.50 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail Permit #: 6329 Permit Date: 01/24/25 Permit Type: FIRE SPRINKLER Project Name: Snohomish County PUD Office Applicant Name: Red Hawk Fire Protection, LLC Applicant Address: 801 Valley Ave NW, Suite D Applicant, City, State, Zip: Puyallup, WA 98371 Contact: Austin Working Phone: 2538409900 Email: insp-permit@redhawkfp.com Scope of Work: To add/relocate 4 sprinklers to accommodate newly added walls and lights. Valuation: 4980.00 Square Feet: 500 Number of Stories: 1 Construction Type: lB Occupancy Group: B; Business ID Code: CIC Permit Issued: 04/21/2025 Permit Expires: 10/20/2025 Form Permit Type: FIRE SPRINKLER Status: COMPLETE Assigned To: Kristin Foster Property Parcel # Address Legal Description Owner Name Owner Phone Zoning PUBLIC UTILITY 184 31052200400200 17601 59TH AVE NE DISTRICT NO 1 GOVERNMENT Contractors Contractor Primary Contact Phone Address Contractor Type License License # Red Hawk Fire 801 Valley Ave CONSTRUCTION Jacob Day 253-840-9900 COA 603 058 495 Protection, LLC NE CONTRACTOR Red Hawk Fire 801 Valley Ave CONSTRUCTION Labor and Jacob Day 253-840-9900 REDHAHF901QP Protection, LLC NE CONTRACTOR Industries Plan Reviews Date Review Type Description Assigned To Review Status 01/27/2025 Fire Suppression BUILDING Approved Fees Fee Description Notes Amount Enter 1 if permit is for: fire alarm, or fire Web Only - Fire System Plan Review $200.00 sprinkler Credit Card Service $6.00 Fire Sprinkler System Commercial NFPA 13/13R $125.00 Processing/Technology $25.00 Credit Card Service $4.50 Total $360.50 Attached Letters Date Letter Description 02/24/2025 Building Permit 01/24/2025 Web Form - Building Application Payments Date Paid By Description Payment Type Accepted By Amount XBP Conf: 01/24/2025 $200.00 221245486 01/24/2025 Matt Rapozo 221245486 Hannah Hardwick $6.00 XBP Conf: 02/24/2025 $150.00 224066322 02/24/2025 Travis Kinne 224066322 $4.50 Outstanding Balance $0.00 Uploaded Files Date File Name 04/21/2025 25552844-20250421_BLD6329_IssuedPermit.pdf 01/27/2025 23985008-20250124_BLD6329_EquipmentSpecs.pdf 01/27/2025 23985009-20250124_BLD6329_Plans.pdf 01/27/2025 23985010-20250124_BLD6329_Application.pdf