HomeMy WebLinkAbout7605 Eaglefield Dr_BLD6398_2025 DH6VS Daikin Fit High-Efficiency, Communicating, 19.0 SEER2 & 8.8 HSPF2 Variable-Speed, 1½ to 5 Tons Inverter Drive Side Discharge R-32 Split System Heat Pump ■ Contents Nomenclature ........................................2 Product Specifications ...........................3 Expanded Cooling Data .........................4 Expanded Heating Data .......................18 Performance Data ...............................22 Sound Data Sound Power ....................................26 Quiet Mode ......................................27 Sound Pressure ................................28 AHRI Ratings (see note) .......................29 Dimensions ..........................................30 Wiring Diagrams ..................................32 Accessories ..........................................34 ■ Standard Features ■ Cabinet Features • Daikin variable-speed swing compressor • Heavy-gauge galvanized steel cabinet with • Quiet digitally commutated fan motor grille-style sound control side design • High-density compressor sound blanket • Custom Ivory white powder-paint finish • Compatible with Daikin One+ smart thermostat and • 500-hour salt-spray tested other Daikin communicating equipment • High corrosion (ZAM®), unpainted • Daikin control algorithmic logic steel bottom frame and legs • Intelligent Defrost Mode • Wire fan discharge grille • In communicating mode, only two low- • Top and side maintenance access voltage wires to outdoor unit required • When properly anchored, meets the 2023 Florida • Diagnostic indicator lights, seven-segment LED display, Building Code unit integrity requirements for and fault code storage hurricane-type winds (Anchor bracket kits available.) • Daikin Inside intelligence for diagnostics • Quiet-mode - provides enhanced acoustical comfort, COLD up to 3 different sound levels (as low as 45dBA) CLIMATE • Field-selectable boost mode increases compressor speed during unusually high loads • Field-installed bi-flow filter drier • Coil and ambient temperature sensors • Suction pressure transducer • Muffler on 1.5-3.0-ton models • Sweat connection service valves with easy access to gauge ports • Advanced water-shedding drain pan • Hot start technology * Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the • AHRI Certified; ETL Listed 12-Year Unit Replacement Limited Warranty and 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Additional requirements for annual maintenance are required for the Unit Replacement Limited Warranty. Online registration and some of the additional requirements are not required in California or Quebéc. The duration of warranty coverage in Texas and Florida differs in some cases. SS-DH6VS-R32 www.daikincomfort.com 08/24 Nomenclature D H 6 V S A 18 1 0 A A 1 2 3 4 5 6 7,8 9 10 11 12 Brand Minor Revision D Daikin A Major Revision Type A H - Heat Pump R-32 Variation SEER2 Electrical 16.0 - 16.9 = 6 1 – 208-230 V, 1 Phase, 60 Hz Compressor Tonnage Nominal V – Variable Speed 18 - 1½ tons 42- 3½ Tons 24 - 2 tons 48- 4 Tons Feature Set 30 - 2½ tons 60- 5 Tons S – Side Discharge Communicating 36 - 3 tons Sales Region A – All 2 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 3 Product Specifications DH6VSA DH6VSA DH6VSA DH6VSA DH6VSA DH6VSA DH6VSA 1810A* 2410A* 3010A* 3610A* 4210A* 4810A* 6010A* Capacities (AHRI Rated) Max. Cooling (BTU/h)-95F 17,100 23,200 28,400 34,200 41,000 45,500 53,500 Max. Heating (BTU/h)-47F 17,400 23,200 28,800 34,600 40,000 45,500 54,500 Max. Heating (BTU/h)-5F 13,000 14,200 17,000 20,000 27,400 28,000 33,000 Ambient Operation Range Cooling (°FDB(°CDB)) 0 to 115 (-17.8 to 46.1)2 Heating (°FDB(°CDB)) -10 to 70 (-23.3 to 21.1) Compressor Type Swing Swing Swing Swing Swing Swing Swing Condenser Fan Motor Horsepower 0.09 0.09 0.20 0.20 0.36 0.36 0.36 Refrigeration System Refrigerant Line Size¹ Liquid Line Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction Line Size (“O.D.) ¾" ¾" ⅞" ⅞" 1⅛" 1⅛" 1⅛" Refrigerant Connection Size Liquid Valve Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction Valve Size (“O.D.) ¾" ¾" ⅞" ⅞" ⅞" ⅞" ⅞" Front and Front and Front and Valve Connection Type Front Sealing Front Sealing Front Sealing Front Sealing Back Sealing Back Sealing Back Sealing Refrigerant Charge (oz.) 74 74 76 83 100 100 118 Expansion Device EEV EEV EEV EEV EEV EEV EEV Superheat at Service Valve Auto-control Auto-control Auto-control Auto-control Auto-control Auto-control Auto-control Subcooling at Service Valve 10±1°F 12±1°F 14±1°F 15±1°F 8±1°F 9±1°F 9±1°F Electrical Data Voltage / Phase (60 Hz) 208-230/1 208-230/1 208-230/1 208-230/1 208-230/1 208-230/1 208-230/1 Fan/Compressor Inverter Drive Input 8.1 13.3 17.6 17.6 25.4 25.4 30 Minimum Circuit Ampacity 2 12.8 16.8 22.4 22.4 31.8 31.8 37.5 Max. Overcurrent Protection 3 15 20 25 25 35 35 40 Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size ½" ½" ½" ½" ½" or ¾" ½" or ¾" ½" or ¾" Equipment Weight (lbs) 122 122 132 137 168 168 179 Ship Weight (lbs) 137 137 147 151 185 185 198 Energy Star® Certified COLD NO NO NO NO NO NO CLIMATE ¹ Tested and rated in accordance with AHRI Standard 210/240 ² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. Notes • Always check the S&R plate for electrical data on the unit being installed. • Installer will need to supply ⅞” to 1⅛” adapters for suction line connections. • Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. (See table below for allowable line set diameter) Energy Star Notes Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. The www.energystar.gov website provides up-to-date system combinations certified to meet ENERGY STAR requirements. Allowable line set diameter Outdoor Unit DH6VS*361*A* Unit Tons Liquid Suction D*96TC0403B/0603B Trim more than 10% ¼ 5⁄ D*97MC0603B settings are invalid. 16 ⅜ ⅝ ¾ ⅞ 1⅛ Indoor Unit D*80TC0603B/0803B Trimmed up CFM makes 1.5 x x x x*1 x MBVK12BP miss matching error. 2.0 x x x*1 x D*96SC0603BU 2.5 x x x*1 x 3.0 x x x*1 x Outdoor Unit DH6VS*601*A* Trim more than 5% 3.5 x x x D*96TC0804C settings are invalid. 4.0 x x x Indoor Unit D*97MC0804C Trimmed up CFM makes 5.0 x x x D*80TC0804C miss matching error. x Allowable combination *1:For marked combinations, if normal ambient operation temperature is less than 14°F, limit line set length to 50 ft. max. 2 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 3 Expanded Cooling Data — DH6VSA1810A* / DFVE24BP1300A* 71 14.90.4814 1.907.748616615.20.5513 1.917.848916815.50.5912 1.917.8491171 67 14.20.4914 1.897.748215314.40.5712 1.907.748415614.70.6011 1.917.8487158 14.20.6217 1.897.748215414.40.6916 1.907.748415614.80.7315 1.907.8487158 115°F 63 13.70.6316 1.897.748014613.90.7015 1.907.748214814.20.7414 1.917.8485150 13.70.7520 1.897.748014613.90.8319 1.907.748314814.30.8618 1.917.8485150kW = Total system power Amps = outdoor unit amps 59 13.40.7018 1.897.747914213.70.9917 1.907.748114414.00.9916 1.917.8484146 13.40.9922 1.897.747914213.70.9920 1.907.748214414.00.9919 1.917.8484147 71 16.10.4313 1.656.542916116.40.5012 1.666.643116316.70.5411 1.666.6434165 67 15.30.4413 1.646.542414815.60.5212 1.656.542715115.90.5611 1.656.6429153 15.30.5716 1.646.542414815.60.6515 1.656.542715115.90.6814 1.656.6430153 105°F 63 14.80.5816 1.646.542314115.10.6515 1.656.542514315.40.6914 1.656.6428145 14.80.7019 1.646.542314115.10.7818 1.656.542514315.40.8217 1.656.6428145 59 14.60.6517 1.646.542113714.80.7316 1.656.642413915.20.7615 1.666.6426142 14.61.0021 1.646.542213714.91.0020 1.656.642413915.21.0019 1.666.6427142 71 17.40.4114 1.435.737615717.70.4913 1.445.737915918.00.5212 1.455.7381161 67 16.60.4213 1.435.637114516.90.5012 1.435.737414717.20.5411 1.445.7376149 16.60.5517 1.425.637214516.90.6316 1.435.737414717.20.6615 1.445.7377149 95°F 63 16.10.5616 1.435.637013716.40.6315 1.445.737213916.70.6714 1.445.7375142 16.10.6920 1.435.637013716.40.7619 1.435.737213916.70.8018 1.445.7375142 59 15.80.6318 1.435.636913416.10.7117 1.445.737113616.40.7516 1.445.7374138 15.91.0022 1.435.636913416.11.0021 1.445.737113616.51.0020 1.445.7374138 71 18.60.3914 1.255.032815318.80.4713 1.265.033015519.20.5112 1.265.0333157 67 17.80.4114 1.244.932314118.00.4813 1.255.032614318.40.5212 1.255.0328145 17.80.5418 1.244.932414118.00.6116 1.255.032614318.40.6515 1.255.0328145Shaded area is ACCA (TVA) conditions Outdoor Ambient Temperature85°F Entering Indoor Wet Bulb Temperature63 17.20.5417 1.244.932213317.50.6216 1.255.032413517.80.6515 1.265.0327138 17.20.6721 1.244.932213317.50.7520 1.255.032413517.80.7819 1.255.0327138 59 17.00.6219 1.245.032113017.20.6918 1.255.032313217.60.7317 1.265.0325134 17.00.7523 1.244.932113017.30.8221 1.255.032313217.61.0120 1.265.0326134 71 19.40.3714 1.084.428414719.70.4513 1.094.428615020.00.4812 1.094.4289152 67 18.60.3814 1.074.427913518.90.4613 1.084.428213819.20.5012 1.094.4284140 18.60.5118 1.074.428013518.90.5917 1.084.428213819.20.6315 1.094.4284140 75°F 63 18.10.5217 1.074.427812818.30.5916 1.084.428013018.70.6315 1.094.4283133 18.10.6521 1.074.427812818.30.7220 1.084.428013018.70.7619 1.094.4283133 59 17.80.6019 1.084.427712518.10.6718 1.084.427912718.40.7117 1.094.4281129 17.80.7223 1.074.427712518.10.8022 1.084.427912718.40.8420 1.094.4282129 71 20.00.3715 0.933.924314120.30.4414 0.943.924514320.60.4812 0.954.0247146 67 19.10.3814 0.933.923812919.40.4613 0.933.924113119.80.4912 0.943.9243134 19.10.5118 0.933.923812919.40.5817 0.933.924113119.80.6216 0.943.9243134 65°F 63 18.60.5218 0.933.923712218.90.5916 0.943.923912419.20.6315 0.943.9241127 18.60.6422 0.933.923712218.90.7220 0.933.923912419.20.7619 0.943.9242127 59 17.80.6222 0.853.623412118.60.6718 0.943.923812119.00.7117 0.944.0240123 17.80.7626 0.853.623412118.60.8022 0.943.923812119.00.8321 0.943.9241123 MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR Airflow 520 610 700 520 610 700 70 75 IDB* IDB*: Entering Indoor Dry Bulb TemperatureHigh and low pressures are measured at the liquid and suction service valves. Airflow may vary depending on actual ambient conditions and system operation modes. 4 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 5 Expanded Cooling Data — DH6VSA1810A* / DFVE24BP1300A* (cont.) 71 15.00.6017 1.907.748716615.30.6816 1.917.848916915.60.7115 1.927.8492171 15.30.7021 1.907.748816815.50.781661.917.849048715.90.8118 1.927.8493173 67 14.30.7421 1.897.748215414.50.8219 1.907.748515614.80.8518 1.917.8487158 14.50.8424 1.897.748315614.80.921541.907.748648215.10.9921 1.917.8489160 115°F 63 13.80.9923 1.897.748014614.00.9922 1.907.748314814.30.9921 1.917.8486151 14.00.9927 1.897.748214814.30.991461.907.848448014.60.9924 1.917.8487152kW = Total system power Amps = outdoor unit amps 59 13.50.9925 1.897.747914313.80.9924 1.907.748214514.10.9923 1.917.8484147 13.80.9928 1.907.748114414.10.991421.907.848347914.40.9926 1.917.8486149 71 16.20.5517 1.656.542916116.50.6316 1.666.643216316.80.6715 1.666.6434166 16.50.6520 1.656.643016316.70.731611.666.643342917.10.7718 1.666.6435168 67 15.40.6920 1.646.542514915.70.7719 1.656.542815116.00.8118 1.656.6430153 15.70.7923 1.646.542615116.00.871481.656.542942516.30.9121 1.666.6431155 105°F 63 14.90.8323 1.646.542314115.20.9022 1.656.542614415.51.0021 1.656.6428146 15.21.0026 1.646.542414315.51.001411.656.642742315.81.0024 1.666.6429148 59 14.71.0025 1.646.542213814.91.0023 1.656.642514015.31.0022 1.666.6427142 15.01.0028 1.646.542314015.21.001371.656.642642215.61.0026 1.666.6428144 71 17.50.5317 1.435.737615717.80.6116 1.445.737916018.10.6515 1.455.7381162 17.80.6321 1.445.737815918.10.711571.455.738037618.40.7519 1.455.7383164 67 16.70.6821 1.435.637214517.10.7520 1.435.737515017.30.7918 1.445.7377150 17.00.7824 1.435.637314717.30.851451.445.737637217.60.8922 1.445.7378152 95°F 63 16.20.8124 1.435.637013816.50.8823 1.445.737314016.80.9222 1.445.7375142 16.51.0027 1.435.637214016.71.001371.445.737437017.11.0025 1.445.7377144 59 15.91.0025 1.435.636913416.21.0024 1.445.737213616.51.0023 1.445.7374139 16.21.0029 1.435.637113616.51.001341.445.737336916.81.0026 1.455.7375140 71 18.70.5218 1.255.032815318.90.5917 1.265.033115519.30.6316 1.265.0333158 19.00.6221 1.255.032915519.20.691531.265.033232819.60.7319 1.275.0334160 Shaded area is AHRI conditions 67 17.90.6621 1.244.932414118.10.7320 1.255.032614318.50.7719 1.255.0329146 18.10.7625 1.244.932514318.40.841411.255.032832418.80.8722 1.265.0330148 Outdoor Ambient Temperature85°F Entering Indoor Wet Bulb Temperature63 17.30.7925 1.244.932213417.60.8723 1.255.032513617.90.9122 1.265.0327138 17.61.0128 1.245.032313617.91.011331.255.032632218.21.0126 1.265.0328140 59 17.11.0126 1.245.032113017.31.0125 1.255.032413217.71.0124 1.265.0326135 17.41.0130 1.245.032213217.61.011301.255.032532118.01.0127 1.265.0327136 71 19.50.5018 1.084.428414819.80.5717 1.094.428715020.10.6116 1.104.4289153 19.80.6022 1.084.428515020.10.671471.094.428828420.40.7119 1.104.5290155 67 18.70.6422 1.074.428013619.00.7120 1.084.428213819.30.7519 1.094.4285141 19.00.7425 1.074.428113819.30.811351.084.428428019.60.8523 1.094.4286142 75°F 63 18.20.7725 1.074.427812918.40.8524 1.084.428113118.80.8923 1.094.4283133 18.50.8728 1.084.427913118.70.951281.084.428227819.10.9926 1.094.4284135 59 17.91.0127 1.074.427712518.21.0125 1.084.428012718.51.0124 1.094.4282130 18.21.0130 1.084.427812718.51.011251.084.428127718.81.0128 1.094.4283132 71 20.10.4919 0.933.924314120.40.5717 0.944.024514420.70.6116 0.954.0248146 20.40.5922 0.943.924414320.70.671410.944.024724321.00.7120 0.954.0249148 67 19.20.6322 0.933.923913019.50.7121 0.933.924113219.90.7520 0.943.9244134 19.50.7426 0.933.924013219.80.811290.943.924223920.20.8523 0.943.9245136 65°F 63 18.70.7726 0.933.923712319.00.8524 0.943.924012519.30.8823 0.943.9242127 19.00.8729 0.933.923812519.30.951220.943.924123719.60.9927 0.944.0243129 59 18.40.8527 0.933.923611918.70.9226 0.943.923912119.11.0125 0.944.0241124 18.71.0131 0.933.923712119.01.011210.943.924023619.41.0128 0.944.0242126 MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR Airflow 520 610 700 520 610 700 80 85 IDB* IDB*: Entering Indoor Dry Bulb TemperatureHigh and low pressures are measured at the liquid and suction service valves.Airflow may vary depending on actual ambient conditions and system operation modes. 4 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 5 Expanded Cooling Data — DH6VSA2410A* / DFVE24BP1300A* 71 20.00.4714 2.9110.152116220.30.5513 2.9310.152416420.80.5812 2.9410.1526167 67 19.00.4914 2.9010.251615019.30.5613 2.9110.151915219.70.6012 2.9210.1522154 19.00.6117 2.9010.251615019.30.6816 2.9110.151915219.80.7215 2.9210.1522154 115°F 63 18.30.6217 2.9010.251414218.70.6916 2.9210.151714419.10.7315 2.9310.1520146 18.30.7420 2.9010.251414218.70.8219 2.9210.151714419.10.8518 2.9310.1520147 kW = Total system power Amps = outdoor unit amps 59 18.00.6919 2.9110.151313818.30.7617 2.9210.151614018.80.8016 2.9310.1518142 18.00.9922 2.9010.251313818.40.9921 2.9210.151614018.80.9920 2.9310.1519142 71 21.70.4214 2.5710.046215722.10.5012 2.5910.046515922.50.5411 2.6010.1467162 67 20.70.4413 2.569.945714521.00.5112 2.5710.046014721.40.5511 2.5810.0463150 20.70.5617 2.569.945714521.00.6416 2.5710.046014721.50.6715 2.5810.0463150 105°F 63 20.00.5716 2.5610.045513720.30.6415 2.5810.045813920.80.6814 2.5910.0461142 20.00.7020 2.569.945513820.30.7719 2.5810.045814020.80.8118 2.5910.0461142 59 19.70.6418 2.5710.045413320.00.7217 2.5810.045713520.40.7516 2.5910.0459137 19.70.7722 2.5610.045413320.01.0020 2.5810.045713520.51.0019 2.5910.0460137 71 23.60.4114 2.299.040715324.00.4813 2.309.041015524.40.5212 2.319.1413158 67 22.50.4214 2.278.940214122.90.4913 2.289.040514423.30.5312 2.299.0408146 22.50.5418 2.278.940314222.90.6216 2.289.040514423.30.6615 2.299.0408146 95°F 63 21.80.5517 2.278.940113422.20.6216 2.299.040313622.60.6615 2.309.0406138 21.80.6821 2.278.940113422.20.7520 2.299.040313622.60.7919 2.309.0406138 59 21.50.6319 2.288.939913021.80.7018 2.299.040213122.30.7416 2.309.1405134 21.50.7523 2.278.940013021.90.8221 2.299.040213222.31.0020 2.309.0405134 71 25.30.3915 2.037.935714925.70.4614 2.047.936015126.10.5013 2.058.0362154 67 24.20.4015 2.017.835213824.60.4813 2.037.935514025.00.5112 2.047.9358142 24.20.5318 2.017.835213824.60.6017 2.027.835514025.00.6416 2.047.9358142Shaded area is ACCA (TVA) conditions Outdoor Ambient Temperature85°F Entering Indoor Wet Bulb Temperature63 23.50.5318 2.027.835013023.80.6117 2.037.935313224.30.6515 2.047.9356134 23.50.6622 2.017.835113023.90.7320 2.037.935313224.30.7719 2.047.9356134 59 23.10.6120 2.027.834912623.50.6818 2.037.935212824.00.7217 2.047.9355130 23.10.7424 2.027.834912623.50.8122 2.037.935212824.00.8521 2.047.9355130 71 26.60.3615 1.796.831114427.00.4414 1.806.931414627.50.4813 1.817.0316149 67 25.50.3815 1.786.830613225.80.4513 1.796.830913526.30.4912 1.806.9311137 25.50.5119 1.776.830613325.90.5817 1.796.830913526.30.6216 1.806.9312137 75°F 63 24.70.5118 1.786.830412525.10.5917 1.796.930712725.60.6216 1.806.9310129 24.70.6422 1.786.830412525.10.7121 1.796.830712725.60.7520 1.806.9310129 59 24.40.5920 1.786.830312124.80.6619 1.796.930612325.20.7017 1.806.9308125 24.40.7124 1.786.830312124.80.7923 1.796.930612325.20.8321 1.806.9309125 71 27.50.3616 1.586.026713827.90.4414 1.596.127014028.40.4713 1.606.1273142 67 26.30.3715 1.566.026312626.70.4514 1.586.026512927.20.4913 1.596.1268131 26.30.5019 1.566.026312626.70.5818 1.586.026512927.20.6117 1.596.1268131 65°F 63 25.60.5119 1.576.026111926.00.5817 1.586.026312126.50.6216 1.596.1266124 25.60.6423 1.576.026111926.00.7121 1.586.026412126.50.7520 1.596.1266124 59 20.30.6322 1.094.424312023.20.6921 1.285.025112026.10.7018 1.596.1265119 20.30.7726 1.094.424412023.20.8325 1.285.025112026.10.8222 1.596.1265119 MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR Airflow 680 800 920 680 800 920 70 75 IDB* IDB*: Entering Indoor Dry Bulb TemperatureHigh and low pressures are measured at the liquid and suction service valves.Airflow may vary depending on actual ambient conditions and system operation modes. 6 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 7 Expanded Cooling Data — DH6VSA2410A* / DFVE24BP1300A* (cont.) 71 20.10.5918 2.9210.152216320.50.6717 2.9310.152416520.90.7016 2.9410.1527167 20.50.6921 2.9210.152316420.80.771622.9310.152652221.30.8019 2.9410.1528169 67 19.10.7321 2.9010.251715119.40.8120 2.9110.152015319.90.8419 2.9210.1522155 19.50.8324 2.9010.251815219.80.901502.9210.152151720.30.9422 2.9310.1524157 115°F 63 18.40.8624 2.9010.251514318.80.9423 2.9210.151814519.20.9922 2.9310.1520147 18.80.9927 2.9110.151614419.20.991422.9210.151951519.60.9925 2.9310.1522149 kW = Total system power Amps = outdoor unit amps 59 18.10.9926 2.9010.251413818.50.9925 2.9210.151714018.90.9924 2.9310.1519142 18.50.9929 2.9110.151514018.80.991382.9210.151851419.30.9927 2.9310.1520144 71 21.80.5517 2.5810.046215822.20.6216 2.5910.046516022.60.6615 2.6010.1468162 22.20.6521 2.5810.046415922.60.721572.5910.046746223.00.7618 2.6010.1469164 67 20.80.6921 2.569.945814621.10.7619 2.5710.046114821.60.8018 2.5810.0463150 21.20.7824 2.5610.045914821.50.861452.5810.046245822.00.8922 2.5910.0464152 105°F 63 20.10.8224 2.5610.045613820.50.8923 2.5810.045914020.90.9322 2.5910.0461142 20.51.0027 2.5710.045714020.81.001382.5810.046045621.31.0025 2.5910.0463144 59 19.81.0025 2.5610.045513420.11.0024 2.5810.045813620.61.0023 2.5910.0460138 20.21.0029 2.5710.045613520.51.001332.5810.045945521.01.0026 2.5910.0461139 71 23.70.5318 2.299.040815424.10.6017 2.309.141115624.50.6416 2.319.1413158 24.10.6322 2.299.040915624.50.701532.309.141240824.90.7419 2.319.1414160 67 22.60.6721 2.278.940314223.20.7420 2.279.240714623.50.7819 2.299.0408146 23.00.7725 2.278.940414423.40.841422.299.040740323.90.8823 2.309.0410148 95°F 63 21.90.8025 2.278.940113422.30.8723 2.299.040413622.80.9122 2.309.0407139 22.31.0028 2.289.040213622.71.001342.299.040540123.21.0026 2.309.1408140 59 21.61.0026 2.288.940013022.01.0025 2.299.040313222.41.0024 2.309.1405134 22.01.0030 2.289.040113222.41.001302.299.040440022.81.0027 2.309.1407136 71 25.40.5119 2.037.935815025.80.5818 2.047.936015226.30.6217 2.058.0363154 25.80.6122 2.037.935915226.20.681492.057.936135826.70.7220 2.068.0364156 Shaded area is AHRI conditions 67 24.30.6522 2.017.835313824.70.7221 2.037.935614025.20.7620 2.047.9358143 24.70.7526 2.027.835414025.10.821382.037.935735325.60.8623 2.047.9359144 Outdoor Ambient Temperature85°F Entering Indoor Wet Bulb Temperature63 23.60.7826 2.027.835113124.00.8624 2.037.935413324.40.8923 2.047.9356135 24.00.8829 2.027.835213224.40.961302.037.935535124.81.0127 2.047.9358137 59 23.31.0127 2.027.835012623.61.0126 2.037.935312824.11.0125 2.047.9355130 23.71.0131 2.027.835112824.01.011262.037.935435024.51.0129 2.057.9356132 71 26.70.4919 1.796.931114427.10.5618 1.806.931414727.60.6017 1.817.0317149 27.10.5923 1.796.931314627.50.661441.816.931531128.00.7020 1.827.0318151 67 25.60.6323 1.786.830713326.00.7021 1.796.830913526.50.7420 1.806.9312138 26.00.7326 1.786.830813526.40.801331.796.931130726.90.8424 1.806.9313139 75°F 63 24.90.7626 1.786.830512625.20.8425 1.796.930812825.70.8724 1.806.9310130 25.30.8630 1.786.830612725.70.941251.806.930930526.10.9727 1.816.9311132 59 24.50.8428 1.786.830412124.91.0127 1.796.930612325.41.0125 1.806.9309126 24.91.0131 1.786.830512325.31.011211.806.930830425.81.0129 1.816.9310127 71 27.60.4820 1.586.026813828.00.5618 1.596.127014028.50.6017 1.606.1273143 28.10.5823 1.586.026914028.40.661381.606.127226828.90.7021 1.616.1274145 67 26.50.6323 1.566.026312726.90.7022 1.586.026612927.40.7421 1.596.1269131 26.90.7327 1.576.026512927.30.801261.586.026726327.80.8425 1.596.1270133 65°F 63 25.70.7627 1.576.026112026.10.8325 1.586.026412226.60.8724 1.596.1267124 26.10.8631 1.576.026312126.50.931191.586.126526127.00.9728 1.596.1268126 59 21.90.8931 1.194.724712025.20.9530 1.425.525511926.20.9526 1.596.1266120 23.41.0135 1.275.025012026.21.011201.596.126424726.71.0130 1.606.1267122 MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR Airflow 680 800 920 680 800 920 80 85 IDB* IDB*: Entering Indoor Dry Bulb TemperatureHigh and low pressures are measured at the liquid and suction service valves.Airflow may vary depending on actual ambient conditions and system operation modes. 6 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 7 Expanded Cooling Data — DH6VSA3010A* / DFVE36CP1300A* 71 24.50.5014 3.5414.052816224.90.5813 3.5514.153116425.40.6212 3.5714.1534167 67 23.20.5214 3.5213.952315023.60.5913 3.5414.052615224.20.6312 3.5514.0529155 23.20.6517 3.5213.952315023.60.7316 3.5314.052615224.20.7715 3.5514.0529155 115°F 63 22.40.6617 3.5213.952114322.80.7316 3.5414.052414523.30.7715 3.5514.1527147 22.40.7920 3.5213.952114322.80.8719 3.5414.052414523.40.9018 3.5514.0527147kW = Total system power Amps = outdoor unit amps 59 22.00.7318 3.5313.952014022.40.8117 3.5414.052314223.01.0116 3.5514.1526144 22.01.0122 3.5213.952014022.51.0121 3.5414.052314223.01.0120 3.5514.1526144 71 26.60.4514 3.1612.447215727.00.5212 3.1812.547515927.50.5611 3.1912.6477162 67 25.30.4613 3.1512.446714525.70.5412 3.1612.447014726.20.5811 3.1812.5472150 25.30.5917 3.1412.446714525.70.6715 3.1612.447014726.30.7114 3.1712.5473150 105°F 63 24.40.6016 3.1512.446513824.90.6815 3.1712.446814025.40.7214 3.1812.5471143 24.50.7320 3.1512.446513824.90.8119 3.1712.446814025.40.8518 3.1812.5471143 59 24.00.6818 3.1512.446413524.50.7617 3.1712.546713725.00.7916 3.1812.5469139 24.11.0121 3.1512.446413524.51.0120 3.1712.446713725.01.0119 3.1812.5470139 71 28.90.4214 2.8411.141915329.30.5013 2.8611.142215529.90.5412 2.8711.2425158 67 27.50.4414 2.8311.041414228.00.5112 2.8411.141714428.50.5511 2.8611.1420146 27.60.5717 2.8311.041514228.00.6416 2.8411.141714428.60.6815 2.8511.1420146 95°F 63 26.70.5717 2.8311.041213527.10.6516 2.8511.141513727.70.6915 2.8611.1418139 26.70.7121 2.8311.041313527.10.7819 2.8511.141513727.70.8218 2.8611.1418139 59 26.30.6519 2.8311.041113126.70.7317 2.8511.141413327.30.7716 2.8611.2417136 26.30.7822 2.8311.041113126.71.0021 2.8511.141413327.31.0020 2.8611.1417136 71 31.00.4015 2.569.837014931.40.4813 2.579.937315132.00.5212 2.5910.0376154 67 29.60.4114 2.549.836513830.10.4913 2.559.836814030.60.5312 2.579.9371142 29.60.5518 2.549.836613830.10.6217 2.559.836814030.60.6616 2.579.9371142Shaded area is ACCA (TVA) conditions Outdoor Ambient Temperature85°F Entering Indoor Wet Bulb Temperature63 28.70.5518 2.549.836413129.20.6316 2.569.936613329.70.6715 2.579.9369135 28.70.6821 2.549.836413129.20.7620 2.569.836713329.80.8019 2.579.9369135 59 28.30.6319 2.549.836212728.80.7118 2.569.936512929.30.7417 2.579.9368132 28.30.7623 2.549.836312728.80.8422 2.569.936513029.40.8721 2.579.9368132 71 32.60.3715 2.298.732514433.00.4514 2.308.732814633.60.4912 2.328.8331149 67 31.20.3914 2.278.632013331.60.4613 2.288.732313532.20.5012 2.308.7326137 31.20.5218 2.278.632013331.70.5917 2.288.732313532.20.6316 2.308.7326137 75°F 63 30.30.5218 2.278.631812630.70.6016 2.298.732112831.30.6415 2.308.7324130 30.30.6522 2.278.631812630.80.7320 2.298.732112831.30.7719 2.308.7324130 59 29.80.6020 2.278.631712330.30.6818 2.298.732012530.90.7217 2.308.8323127 29.90.7324 2.278.631712330.30.8122 2.298.732012530.90.8521 2.308.7323127 71 33.70.3715 2.047.628213834.20.4414 2.067.728514034.80.4813 2.077.7287142 67 32.20.3815 2.027.527712632.70.4613 2.047.628012933.30.4912 2.057.7282131 32.30.5119 2.027.527712732.70.5818 2.047.628012933.30.6216 2.057.7283131 65°F 63 31.30.5218 2.037.627512031.80.5917 2.047.627812232.40.6316 2.067.7280124 31.30.6422 2.037.527512031.80.7221 2.047.627812232.40.7620 2.067.7281124 59 31.00.6022 1.826.727411931.50.6821 1.846.827712132.00.7118 2.067.7279121 31.00.7327 1.826.727411931.50.8125 1.846.827712132.00.8322 2.067.7279121 MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR Airflow 860 1010 1160 860 1010 1160 70 75 IDB* IDB*: Entering Indoor Dry Bulb TemperatureHigh and low pressures are measured at the liquid and suction service valves.Airflow may vary depending on actual ambient conditions and system operation modes. 8 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 9 Expanded Cooling Data — DH6VSA3010A* / DFVE36CP1300A* (cont.) 71 24.60.63183.5414.052916325.00.7117 3.5514.153116525.50.7516 3.5714.1534167 25.10.7321 3.5414.053016425.50.811623.5614.153352926.00.8519 3.5714.1535169 67 23.40.78213.5213.952415123.80.8620 3.5314.052715324.30.8919 3.5514.0529155 23.80.8824 3.5213.952515324.20.961503.5414.052852424.81.0022 3.5514.1531157 115°F 63 22.60.92243.5213.952214423.01.0123 3.5414.052514623.51.0122 3.5514.1527148 23.01.0127 3.5314.052314523.41.011433.5414.052652224.01.0125 3.5614.1529150kW = Total system power Amps = outdoor unit amps 59 22.21.01253.5313.952114022.61.0124 3.5414.052414223.11.0123 3.5514.1526144 22.61.0129 3.5314.052214223.11.011403.5514.052552123.61.0126 3.5614.1528146 71 26.70.58173.1712.447215827.10.6516 3.1812.547516027.70.6915 3.1912.6478162 27.20.6820 3.1712.547415927.60.761573.1912.547747228.10.7918 3.2012.6479164 67 25.40.72203.1512.446814625.90.8019 3.1612.447014826.40.8418 3.1812.5473150 25.90.8224 3.1512.446914826.30.901453.1712.447246826.90.9421 3.1812.5475152 105°F 63 24.60.86233.1512.446613925.00.9422 3.1712.446914125.60.9821 3.1812.5471143 25.11.0127 3.1612.446714125.51.011383.1712.547046626.01.0124 3.1812.5473145 59 24.21.01253.1512.446513524.61.0124 3.1712.546713725.21.0123 3.1812.5470140 24.71.0128 3.1612.446613725.11.011353.1712.546946525.61.0126 3.1912.5471141 71 29.00.55182.8511.142015429.50.6317 2.8611.242315630.00.6716 2.8811.2425158 29.50.6521 2.8511.142115629.90.731532.8711.242442030.50.7719 2.8811.2427160 67 27.70.70212.8311.041514228.40.7720 2.8411.041514628.70.8119 2.8611.1421147 28.20.8025 2.8311.041614428.60.881422.8511.141941529.20.9122 2.8611.1422148 95°F 63 26.90.83242.8311.041313527.30.9123 2.8511.141613727.80.9522 2.8611.1419139 27.31.0028 2.8411.041413727.81.001352.8511.141741328.31.0025 2.8711.2420141 59 26.41.00262.8311.041213226.91.0025 2.8511.141513427.41.0024 2.8611.2417136 26.91.0029 2.8411.141313427.41.001312.8511.141641227.91.0027 2.8711.2419138 71 31.10.53192.569.837115031.60.6017 2.579.937415232.10.6416 2.5910.0376154 31.60.6322 2.569.937215132.10.711492.589.937537132.60.7520 2.5910.0378156 Shaded area is AHRI conditions 67 29.80.67222.549.836613830.20.7521 2.559.836914030.80.7920 2.579.9372143 30.30.7825 2.549.836714030.70.851382.569.937036631.30.8923 2.579.9373144 Outdoor Ambient Temperature85°F Entering Indoor Wet Bulb Temperature63 28.90.81252.549.836413129.40.8924 2.569.936713329.90.9223 2.579.9370136 29.40.9129 2.559.836613329.80.991312.569.936836430.41.0026 2.589.9371137 59 28.51.00272.549.836312828.91.0026 2.569.936613029.51.0025 2.579.9369132 29.01.0030 2.559.836413029.41.001272.579.936736330.01.0028 2.589.9370134 71 32.70.50192.298.732614433.20.5818 2.308.832814733.80.6116 2.328.8331149 33.20.6022 2.298.732714633.70.681442.318.833032634.30.7220 2.328.8332151 67 31.30.64222.278.632113331.80.7221 2.288.732413532.40.7620 2.308.7326138 31.90.7526 2.278.632213532.30.821332.298.732532132.90.8623 2.308.7328139 75°F 63 30.40.78262.278.631912630.90.8624 2.298.732212831.50.8923 2.308.7324131 31.00.8829 2.288.632012831.40.961262.298.732331932.00.9927 2.318.8326132 59 30.00.99272.278.631812330.50.9926 2.298.732112531.10.9925 2.308.8323127 30.50.9931 2.288.631912531.00.991232.308.732231831.60.9929 2.318.8325129 71 33.80.49192.047.628213834.30.5718 2.067.728514034.90.6117 2.077.8288143 34.40.5923 2.057.628414034.80.671382.067.728628235.40.7121 2.087.8289145 67 32.40.63232.027.527812732.90.7122 2.047.628012933.50.7520 2.057.7283132 32.90.7427 2.037.627912933.40.811272.047.628227834.00.8524 2.067.7284133 65°F 63 31.50.77262.037.627612032.00.8525 2.047.627812232.60.8824 2.067.7281125 32.00.8730 2.037.627712232.50.951202.057.628027633.10.9928 2.067.7282127 59 31.20.86311.826.727412031.50.9227 2.057.627711932.10.9626 2.067.7280122 31.70.9935 1.836.827612232.10.991192.057.727927432.70.9929 2.067.7281123 MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR Airflow 860 1010 1160 860 1010 1160 80 85 IDB* IDB*: Entering Indoor Dry Bulb TemperatureHigh and low pressures are measured at the liquid and suction service valves.Airflow may vary depending on actual ambient conditions and system operation modes. 8 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 9 Expanded Cooling Data — DH6VSA3610A* / DFVE36CP1300A* 71 29.60.5115 4.3917.052216930.10.5914 4.4117.052517130.80.6313 4.4317.1527174 67 28.10.5215 4.3716.951715728.60.6013 4.3916.952015929.20.6412 4.4117.0522161 28.10.6618 4.3716.951715728.60.7317 4.3916.952015929.30.7716 4.4017.0523161 115°F 63 27.10.6618 4.3816.951515027.60.7417 4.4017.051815228.30.7815 4.4117.0521154 27.10.8022 4.3716.951515027.70.8720 4.3917.051815228.30.9119 4.4117.0521154kW = Total system power Amps = outdoor unit amps 59 26.71.0020 4.3816.951414727.21.0018 4.4017.051714927.81.0017 4.4117.0519151 26.71.0023 4.3816.951414727.21.0022 4.4017.051714927.81.0021 4.4117.0520151 71 31.60.4413 4.3116.747516032.20.5212 4.3416.847716232.80.5611 4.3516.8480165 67 30.10.4612 4.2916.646914830.60.5311 4.3116.747215031.30.5710 4.3316.7475153 30.10.5916 4.2916.647014830.60.6615 4.3116.747315031.30.7014 4.3316.7475153 105°F 63 29.10.5915 4.2916.646814129.60.6714 4.3216.747014330.30.7113 4.3316.8473146 29.10.7319 4.2916.646814129.60.8018 4.3116.747114330.30.8417 4.3316.7473146 59 28.60.6717 4.3016.646613929.20.7516 4.3216.746914129.80.7915 4.3416.8472143 28.71.0020 4.3016.646713929.21.0019 4.3216.746914129.81.0018 4.3416.8472143 71 34.50.4213 3.8514.842815435.10.5012 3.8714.943115635.70.5411 3.8915.0434158 67 32.90.4413 3.8314.742314233.50.5112 3.8514.842614434.10.5511 3.8714.9428147 33.00.5717 3.8214.742314233.50.6415 3.8514.842614434.20.6814 3.8614.9429147 95°F 63 31.90.5716 3.8314.842113532.50.6515 3.8514.842413833.10.6914 3.8714.9426140 31.90.7120 3.8314.742113632.50.7818 3.8514.842413833.10.8217 3.8714.9427140 59 31.40.6518 3.8314.842013332.00.7316 3.8614.942213532.60.7715 3.8714.9425137 31.50.7821 3.8314.842013332.01.0020 3.8514.842313532.71.0019 3.8714.9425137 71 37.20.4014 3.4313.138414737.70.4813 3.4613.238714938.40.5212 3.4713.3389152 67 35.50.4214 3.4113.037813636.10.4912 3.4313.138113836.80.5311 3.4513.2384140 35.60.5517 3.4113.037913636.10.6316 3.4313.138213836.80.6715 3.4513.2384140Shaded area is ACCA (TVA) conditions Outdoor Ambient Temperature85°F Entering Indoor Wet Bulb Temperature63 34.50.5617 3.4213.137613035.00.6316 3.4413.137913235.70.6715 3.4613.2382134 34.50.6921 3.4113.037713035.10.7619 3.4413.138013235.70.8018 3.4513.2382134 59 34.00.6319 3.4213.137512734.50.7117 3.4413.237812935.20.7516 3.4613.2381131 34.00.7722 3.4213.137512734.60.8421 3.4413.137812935.20.8820 3.4613.2381131 71 39.20.3814 3.0511.534214039.80.4613 3.0711.634414240.50.5012 3.0911.7347145 67 37.60.3914 3.0311.433612938.10.4713 3.0511.533913138.80.5112 3.0711.6342133 37.60.5318 3.0211.433612938.10.6016 3.0511.533913138.80.6415 3.0611.6342133 75°F 63 36.50.5317 3.0311.433412337.00.6116 3.0511.533712537.70.6515 3.0711.6340127 36.50.6621 3.0311.433412337.10.7420 3.0511.533712537.80.7819 3.0711.6340127 59 36.00.6119 3.0311.533312036.50.6918 3.0611.633612237.20.7317 3.0711.6339125 36.00.7423 3.0311.433312036.50.8221 3.0511.533612237.20.8620 3.0711.6339125 71 40.70.3715 2.7010.130013241.30.4514 2.7310.230313442.00.4912 2.7410.2306136 67 39.00.3914 2.6810.029512139.60.4713 2.7010.029812340.30.5012 2.7210.1301126 39.00.5218 2.689.929512139.60.6017 2.7010.029812340.30.6416 2.7210.1301126 65°F 63 34.10.5520 1.997.228711937.50.6318 2.278.329311939.20.6415 2.7310.2299119 34.10.6924 1.987.228711937.50.7723 2.278.329311939.20.7819 2.7210.1299119 59 30.30.6521 1.756.328211932.50.7320 1.896.828712037.70.7519 2.298.4295119 30.30.8026 1.756.328211932.50.8724 1.886.828712037.70.8924 2.298.4295119 MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR Airflow 1070 1260 1450 1070 1260 1450 70 75 IDB* IDB*: Entering Indoor Dry Bulb TemperatureHigh and low pressures are measured at the liquid and suction service valves.Airflow may vary depending on actual ambient conditions and system operation modes. 10 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 11 Expanded Cooling Data — DH6VSA3610A* / DFVE36CP1300A* (cont.) 71 29.60.5115 4.3917.052216930.10.5914 4.4117.052517130.80.6313 4.4317.1527174 71 29.80.6419 4.3917.052216930.30.7218 4.4117.052517230.90.7617 4.4317.1528174 30.30.7422 4.4017.052417130.90.821694.4217.152752231.50.8620 4.4417.1529176 67 28.10.5215 4.3716.951715728.60.6013 4.3916.952015929.20.6412 4.4117.0522161 28.10.6618 4.3716.951715728.60.7317 4.3916.952015929.30.7716 4.4017.0523161 67 28.30.7922 4.3716.951815728.80.8621 4.3916.952115929.40.9020 4.4117.0523162 28.81.0026 4.3816.951915929.41.001574.4017.052251830.01.0023 4.4117.0525163 115°F 115°F 63 27.10.6618 4.3816.951515027.60.7417 4.4017.051815228.30.7815 4.4117.0521154 27.10.8022 4.3716.951515027.70.8720 4.3917.051815228.30.9119 4.4117.0521154kW = Total system power 63 27.31.0025 4.3816.951615027.81.0024 4.3917.051915228.51.0023 4.4117.0521154 27.91.0029 4.3816.951715228.41.001504.4017.052051629.01.0026 4.4217.1523156kW = Total system power Amps = outdoor unit amps Amps = outdoor unit amps 59 26.71.0020 4.3816.951414727.21.0018 4.4017.051714927.81.0017 4.4117.0519151 26.71.0023 4.3816.951414727.21.0022 4.4017.051714927.81.0021 4.4117.0520151 59 26.81.0027 4.3816.951514727.41.0026 4.4017.051714928.01.0025 4.4117.0520152 27.41.0030 4.3816.951614927.91.001474.4017.051951528.51.0028 4.4217.1521154 71 31.60.4413 4.3116.747516032.20.5212 4.3416.847716232.80.5611 4.3516.8480165 71 31.80.5716 4.3116.747516132.30.6515 4.3416.847816333.00.6914 4.3516.8481165 32.40.6719 4.3216.747616232.90.751604.3416.847947533.50.7917 4.3616.9482167 67 30.10.4612 4.2916.646914830.60.5311 4.3116.747215031.30.5710 4.3316.7475153 30.10.5916 4.2916.647014830.60.6615 4.3116.747315031.30.7014 4.3316.7475153 67 30.30.7219 4.2916.647014930.80.7918 4.3116.747315131.50.8317 4.3316.7476153 30.90.8222 4.2916.647215131.40.891484.3216.747447032.00.9320 4.3316.8477155 105°F 105°F 63 29.10.5915 4.2916.646814129.60.6714 4.3216.747014330.30.7113 4.3316.8473146 29.10.7319 4.2916.646814129.60.8018 4.3116.747114330.30.8417 4.3316.7473146 63 29.30.8522 4.2916.646814229.80.9321 4.3216.747114430.51.0020 4.3316.8474146 29.91.0025 4.3016.647014430.41.001414.3216.747246831.01.0023 4.3416.8475148 59 28.60.6717 4.3016.646613929.20.7516 4.3216.746914129.80.7915 4.3416.8472143 28.71.0020 4.3016.646713929.21.0019 4.3216.746914129.81.0018 4.3416.8472143 59 28.81.0024 4.3016.646713929.41.0023 4.3216.747014130.01.0022 4.3416.8473144 29.41.0027 4.3016.646814129.91.001394.3316.747146730.61.0025 4.3416.8474145 71 34.50.4213 3.8514.842815435.10.5012 3.8714.943115635.70.5411 3.8915.0434158 71 34.70.5517 3.8514.842815435.20.6316 3.8714.943115635.90.6715 3.8915.0434159 35.30.6520 3.8614.943015635.80.731543.8815.043342836.50.7718 3.9015.0435161 67 32.90.4413 3.8314.742314233.50.5112 3.8514.842614434.10.5511 3.8714.9428147 33.00.5717 3.8214.742314233.50.6415 3.8514.842614434.20.6814 3.8614.9429147 67 33.10.6920 3.8214.742314334.20.7719 3.8014.442614634.30.8118 3.8714.9429147 33.70.8023 3.8314.842514434.30.871423.8514.842842334.90.9121 3.8714.9430149 95°F 95°F 63 31.90.5716 3.8314.842113532.50.6515 3.8514.842413833.10.6914 3.8714.9426140 31.90.7120 3.8314.742113632.50.7818 3.8514.842413833.10.8217 3.8714.9427140 63 32.10.8323 3.8314.742213632.70.9122 3.8514.842413833.30.9521 3.8714.9427140 32.71.0026 3.8414.842313833.21.001363.8614.942642233.91.0024 3.8814.9428142 59 31.40.6518 3.8314.842013332.00.7316 3.8614.942213532.60.7715 3.8714.9425137 31.50.7821 3.8314.842013332.01.0020 3.8514.842313532.71.0019 3.8714.9425137 59 31.61.0025 3.8314.842013332.21.0024 3.8614.942313532.81.0023 3.8714.9426138 32.21.0028 3.8414.842213532.71.001333.8614.942542033.41.0026 3.8815.0427139 71 37.20.4014 3.4313.138414737.70.4813 3.4613.238714938.40.5212 3.4713.3389152 71 37.40.5318 3.4413.138414837.90.6117 3.4613.238715038.60.6516 3.4813.3390152 38.00.6321 3.4413.238515038.50.711473.4713.338838439.20.7519 3.4813.3391154 Shaded area is AHRI conditions 67 35.50.4214 3.4113.037813636.10.4912 3.4313.138113836.80.5311 3.4513.2384140 35.60.5517 3.4113.037913636.10.6316 3.4313.138213836.80.6715 3.4513.2384140Shaded area is ACCA (TVA) conditions 67 35.80.6821 3.4113.037913736.30.7520 3.4313.138213937.00.7919 3.4513.2385141 36.30.7824 3.4213.138013836.90.861363.4413.138337937.60.9022 3.4613.2386143 Outdoor Ambient Temperature85°F Outdoor Ambient Temperature85°F Entering Indoor Wet Bulb Temperature63 34.50.5617 3.4213.137613035.00.6316 3.4413.137913235.70.6715 3.4613.2382134 34.50.6921 3.4113.037713035.10.7619 3.4413.138013235.70.8018 3.4513.2382134 Entering Indoor Wet Bulb Temperature63 34.70.8224 3.4213.037713035.20.8923 3.4413.138013235.90.9322 3.4613.2383134 35.30.9228 3.4213.137813235.81.001303.4413.238137736.51.0125 3.4613.2384136 59 34.00.6319 3.4213.137512734.50.7117 3.4413.237812935.20.7516 3.4613.2381131 34.00.7722 3.4213.137512734.60.8421 3.4413.137812935.20.8820 3.4613.2381131 59 34.21.0126 3.4213.137612834.71.0125 3.4413.237913035.41.0124 3.4613.2382132 34.81.0129 3.4213.137712935.31.011273.4513.238037636.01.0127 3.4713.3383134 71 39.20.3814 3.0511.534214039.80.4613 3.0711.634414240.50.5012 3.0911.7347145 71 39.40.5118 3.0511.534214140.00.5817 3.0711.634514340.70.6216 3.0911.7348145 40.00.6122 3.0611.634314240.60.691403.0811.734634241.30.7319 3.1011.7349147 67 37.60.3914 3.0311.433612938.10.4713 3.0511.533913138.80.5112 3.0711.6342133 37.60.5318 3.0211.433612938.10.6016 3.0511.533913138.80.6415 3.0611.6342133 67 37.80.6522 3.0211.433713038.30.7320 3.0511.534013239.00.7719 3.0711.6343134 38.40.7625 3.0311.433813138.90.831293.0511.534133739.70.8723 3.0711.6344136 75°F 75°F 63 36.50.5317 3.0311.433412337.00.6116 3.0511.533712537.70.6515 3.0711.6340127 36.50.6621 3.0311.433412337.10.7420 3.0511.533712537.80.7819 3.0711.6340127 63 36.70.7925 3.0311.433512337.20.8723 3.0511.533812538.00.9122 3.0711.6341128 37.30.9028 3.0411.533612537.90.971233.0611.633933538.61.0126 3.0811.6342129 59 36.00.6119 3.0311.533312036.50.6918 3.0611.633612237.20.7317 3.0711.6339125 36.00.7423 3.0311.433312036.50.8221 3.0511.533612237.20.8620 3.0711.6339125 59 36.20.8726 3.0311.533412136.71.0125 3.0611.533712337.41.0124 3.0711.6340125 36.81.0130 3.0411.533512337.31.011203.0611.633833438.11.0128 3.0811.7341127 71 40.70.3715 2.7010.130013241.30.4514 2.7310.230313442.00.4912 2.7410.2306136 71 40.90.5019 2.7110.130113241.50.5818 2.7310.230413442.20.6216 2.7510.2307137 41.50.6122 2.7110.130213442.10.681322.7410.230530142.80.7220 2.7510.3308139 67 39.00.3914 2.6810.029512139.60.4713 2.7010.029812340.30.5012 2.7210.1301126 39.00.5218 2.689.929512139.60.6017 2.7010.029812340.30.6416 2.7210.1301126 67 39.20.6522 2.689.929612239.80.7321 2.7010.029912440.50.7720 2.7210.1302126 39.80.7526 2.6910.029712440.40.831212.7110.130029641.10.8723 2.7310.2303128 65°F 65°F 63 34.10.5520 1.997.228711937.50.6318 2.278.329311939.20.6415 2.7310.2299119 34.10.6924 1.987.228711937.50.7723 2.278.329311939.20.7819 2.7210.1299119 63 34.30.8328 1.987.228812037.70.9027 2.278.329412039.40.9023 2.7310.2300120 37.80.9333 2.268.229212039.30.971192.7110.129828840.01.0127 2.7310.2301122 59 30.30.6521 1.756.328211932.50.7320 1.896.828712037.70.7519 2.298.4295119 30.30.8026 1.756.328211932.50.8724 1.886.828712037.70.8924 2.298.4295119 59 30.50.9330 1.756.328312034.30.9929 2.007.328912037.91.0128 2.298.4296120 34.41.0134 1.997.228811937.81.011192.288.329428339.51.0128 2.7410.2300119 MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR Airflow Airflow 1070 1260 1450 1070 1260 1450 1070 1260 1450 1070 1260 1450 IDB* 70 75 IDB* 80 85 IDB*: Entering Indoor Dry Bulb TemperatureHigh and low pressures are measured at the liquid and suction service valves.Airflow may vary depending on actual ambient conditions and system operation modes. IDB*: Entering Indoor Dry Bulb TemperatureHigh and low pressures are measured at the liquid and suction service valves.Airflow may vary depending on actual ambient conditions and system operation modes. 10 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 11 Expanded Cooling Data — DH6VSA4210A* / DFVE48DP1300A* 71 32.80.4817 3.1211.052216433.40.5515 3.1311.052516634.10.5914 3.1411.0527169 67 31.10.4916 3.1011.051715231.70.5715 3.1211.152015432.40.6014 3.1311.1522157 31.20.6221 3.1011.051715231.70.6919 3.1111.152015432.40.7318 3.1311.1523157 115°F 63 30.00.6220 3.1111.151514430.60.7019 3.1211.151814631.30.7317 3.1311.1521148 30.10.7524 3.1011.151514430.60.8223 3.1211.151814631.30.8622 3.1311.1521148kW = Total system power Amps = outdoor unit amps 59 29.50.7022 3.1111.151413830.10.7720 3.1211.151714030.80.8119 3.1311.2519142 29.61.0026 3.1111.151413830.11.0025 3.1211.151714030.81.0024 3.1311.1520142 71 39.50.4215 5.0118.548515540.10.4914 5.0418.648815740.90.5313 5.0618.7491160 67 37.60.4315 4.9818.448014438.20.5113 5.0118.548314639.00.5412 5.0318.6486148 37.60.5619 4.9818.448114438.20.6317 5.0018.548314639.00.6716 5.0318.6486148 105°F 63 36.30.5618 4.9918.547813637.00.6417 5.0118.648113737.80.6716 5.0418.6484140 36.40.6922 4.9818.547913637.00.7621 5.0118.648113837.80.8020 5.0318.6484140 59 35.80.6420 4.9918.547713036.40.7119 5.0218.648013237.20.7517 5.0418.7483134 35.80.7624 4.9918.547713036.40.8323 5.0118.648013237.21.0021 5.0418.6483134 71 41.90.4015 4.5517.843015242.50.4714 4.5817.943315443.30.5113 4.6018.0436156 67 40.00.4115 4.5217.742514040.60.4914 4.5517.842814241.40.5212 4.5717.9431145 40.00.5419 4.5217.742514040.60.6118 4.5417.842814341.40.6516 4.5717.9431145 95°F 63 38.70.5418 4.5317.742313239.40.6217 4.5517.842613440.20.6516 4.5817.9429137 38.70.6722 4.5217.742313339.40.7421 4.5517.842613440.20.7820 4.5717.9429137 59 38.10.6220 4.5317.742212738.80.6919 4.5617.942512939.60.7318 4.5817.9428131 38.20.7424 4.5317.742212738.80.8123 4.5517.842512939.60.8522 4.5817.9428131 71 43.80.3816 4.1317.037914844.50.4614 4.1517.138215145.30.4913 4.1817.2385153 67 41.90.4015 4.0916.837413742.60.4714 4.1217.037713943.40.5113 4.1517.1380142 41.90.5219 4.0916.837413742.60.5918 4.1216.937713943.40.6317 4.1417.0380142Shaded area is ACCA (TVA) conditions Outdoor Ambient Temperature85°F Entering Indoor Wet Bulb Temperature63 40.70.5319 4.1016.937212941.30.6017 4.1317.037513142.10.6416 4.1517.1378133 40.70.6523 4.1016.937312941.30.7221 4.1317.037513142.10.7620 4.1517.1378133 59 40.10.6021 4.1116.937112440.70.6719 4.1317.037412641.50.7118 4.1617.1377128 40.10.7225 4.1016.937112440.80.8023 4.1317.037412641.60.8322 4.1517.1377128 71 45.00.3616 3.7216.033214445.70.4314 3.7516.133514646.50.4713 3.7716.2338148 67 43.10.3715 3.6915.832713343.80.4514 3.7215.933013544.60.4813 3.7416.0333137 43.10.5019 3.6915.832713343.80.5718 3.7115.933013544.60.6117 3.7416.0333137 75°F 63 41.90.5019 3.7015.832512542.50.5817 3.7216.032812743.30.6116 3.7516.1331129 41.90.6323 3.6915.832512542.50.7021 3.7216.032812743.30.7420 3.7416.1331129 59 41.30.5820 3.7015.932412041.90.6519 3.7316.032712242.70.6918 3.7516.1330124 41.30.7025 3.7015.832412041.90.7823 3.7216.032712242.80.8122 3.7516.1330124 71 45.50.3516 3.3414.928713846.20.4314 3.3715.029014047.00.4613 3.4015.1293143 67 43.60.3715 3.3114.728212744.20.4414 3.3414.928512945.00.4813 3.3715.0288131 43.60.4919 3.3114.728212744.30.5718 3.3414.828512945.10.6017 3.3615.0288132 65°F 63 42.30.5019 3.3214.728011943.00.5717 3.3514.928312143.80.6116 3.3715.0286124 42.40.6223 3.3214.728111943.00.7021 3.3514.928312143.80.7320 3.3715.0286124 59 33.50.5921 1.668.226111937.80.6520 1.999.427112042.90.6719 2.4210.9283120 33.50.7225 1.668.226111937.80.7824 1.999.427212042.90.8024 2.4110.9283120 MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR Airflow 1120 1320 1520 1120 1320 1520 70 75 IDB* IDB*: Entering Indoor Dry Bulb TemperatureHigh and low pressures are measured at the liquid and suction service valves.Airflow may vary depending on actual ambient conditions and system operation modes. 12 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 13 Expanded Cooling Data — DH6VSA4210A* / DFVE48DP1300A* (cont.) 71 33.00.6021 3.1211.052216533.60.6720 3.1311.052516734.30.7119 3.1411.0528169 33.60.7025 3.1211.052416734.20.771643.1411.052652234.90.8122 3.1511.0529171 67 31.30.7425 3.1011.051815331.90.8123 3.1211.152015532.60.8522 3.1311.1523157 32.00.8429 3.1111.151915532.50.911523.1211.152251833.21.0026 3.1311.1524159 115°F 63 30.30.8728 3.1111.151614430.81.0027 3.1211.151914631.51.0026 3.1311.1521149 30.91.0032 3.1111.151714631.41.001443.1211.152051632.11.0030 3.1411.2523150kW = Total system power Amps = outdoor unit amps 59 29.71.0030 3.1111.151513930.31.0029 3.1211.151714131.01.0028 3.1311.2520143 30.41.0034 3.1111.151614130.91.001383.1311.151951531.61.0032 3.1411.2521145 71 39.70.5419 5.0118.648615640.40.6118 5.0418.748915841.20.6517 5.0618.7492160 40.40.6423 5.0218.648715741.10.711555.0518.749048641.90.7520 5.0718.8493162 67 37.80.6823 4.9818.448114438.50.7521 5.0118.548414639.30.7920 5.0318.6487148 38.50.7826 4.9918.548214639.20.851445.0118.648548140.00.8824 5.0418.6488150 105°F 63 36.60.8126 4.9918.547913637.20.8825 5.0118.648213838.00.9224 5.0318.6485140 37.31.0030 4.9918.548013837.91.001365.0218.648347938.71.0027 5.0418.7486142 59 36.01.0028 4.9918.547813136.61.0027 5.0218.648113337.41.0026 5.0418.7484135 36.71.0032 5.0018.547913237.31.001305.0218.648247838.11.0029 5.0518.7485136 71 42.10.5220 4.5517.843115242.70.5918 4.5817.943415543.50.6317 4.6018.0437157 42.80.6223 4.5617.943215443.40.691524.5918.043543144.20.7321 4.6118.1438159 67 40.20.6623 4.5217.742614141.00.7322 4.5618.842914541.60.7721 4.5717.9432145 40.90.7627 4.5317.742714341.50.831404.5517.843042642.30.8724 4.5817.9433147 95°F 63 39.00.7927 4.5317.742413339.60.8625 4.5517.842713540.40.9024 4.5817.9430137 39.70.8930 4.5317.842513540.31.001334.5617.942842441.11.0028 4.5818.0431139 59 38.41.0028 4.5317.742312839.01.0027 4.5617.942613039.81.0026 4.5817.9428132 39.11.0032 4.5417.842412939.71.001274.5617.942742340.51.0030 4.5918.0430133 71 44.10.5020 4.1317.038014944.70.5818 4.1617.138315145.50.6117 4.1817.2386154 44.80.6024 4.1417.038115145.40.671484.1617.138438046.20.7121 4.1917.2387155 Shaded area is AHRI conditions 67 42.20.6423 4.0916.837513842.80.7122 4.1217.037814043.60.7521 4.1417.1381142 42.90.7427 4.1016.937613943.50.811374.1317.037937544.30.8525 4.1517.1382144 Outdoor Ambient Temperature85°F Entering Indoor Wet Bulb Temperature63 40.90.7727 4.1016.937313041.60.8526 4.1317.037613242.40.8824 4.1517.1379134 41.60.8731 4.1116.937413142.30.941294.1417.037737343.11.0028 4.1617.1380136 59 40.31.0029 4.1116.937212441.01.0027 4.1317.037512641.81.0026 4.1617.1377129 41.01.0032 4.1116.937312641.71.001244.1417.037637242.51.0030 4.1617.1379130 71 45.30.4820 3.7216.033314445.90.5518 3.7516.133614746.70.5917 3.7716.2338149 46.00.5823 3.7316.033414646.60.651443.7616.133733347.40.6921 3.7816.2340151 67 43.40.6223 3.6915.832813344.00.6922 3.7215.933113544.80.7321 3.7416.0333138 44.10.7227 3.7015.832913544.70.791333.7216.033232845.50.8324 3.7516.1335139 75°F 63 42.10.7527 3.7015.832612542.80.8225 3.7216.032912743.60.8624 3.7516.1332130 42.80.8530 3.7015.932712743.50.921253.7316.033032644.30.9628 3.7516.1333131 59 41.50.8229 3.7015.932512042.20.9027 3.7316.032812243.01.0126 3.7516.1330124 42.21.0132 3.7115.932612242.91.011203.7416.032932543.71.0130 3.7616.1332126 71 45.70.4820 3.3514.928813846.40.5518 3.3815.029114147.20.5917 3.4015.1294143 46.40.5723 3.3614.928914047.10.651383.3815.129228847.90.6821 3.4115.2295145 67 43.80.6123 3.3114.728312744.50.6922 3.3414.828613045.30.7221 3.3615.0289132 44.50.7127 3.3214.728412945.20.791273.3514.928728346.00.8225 3.3715.0290134 65°F 63 42.60.7527 3.3214.728112043.20.8226 3.3514.928412244.00.8624 3.3715.0287124 43.30.8431 3.3314.828212243.90.921193.3614.928528144.70.9528 3.3815.0288126 59 34.90.8430 1.768.626411938.00.9029 1.999.427212043.40.9326 3.3815.0285119 38.11.0134 1.989.327112043.01.011192.4010.928226444.11.0130 3.3815.1287121 MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR Airflow 1120 1320 1520 1120 1320 1520 80 85 IDB* IDB*: Entering Indoor Dry Bulb TemperatureHigh and low pressures are measured at the liquid and suction service valves.Airflow may vary depending on actual ambient conditions and system operation modes. 12 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 13 Expanded Cooling Data — DH6VSA4810A* / DFVE48DP1300A* 71 33.00.4817 3.3413.752115833.60.5515 3.3613.852416034.30.5914 3.3713.8527162 67 31.30.4916 3.3213.651614731.90.5715 3.3413.751914932.60.6014 3.3513.8522151 31.40.6220 3.3213.651614731.90.6919 3.3413.751914932.60.7318 3.3513.8522151 115°F 63 30.20.6220 3.3313.751413830.80.7018 3.3413.751714031.50.7317 3.3613.8520142 30.30.7524 3.3313.751513830.80.8222 3.3413.751714031.50.8621 3.3513.8520142kW = Total system power Amps = outdoor unit amps 59 29.70.7021 3.3313.751313230.30.7720 3.3413.751613331.00.8119 3.3613.8519136 29.70.8226 3.3313.751313230.31.0124 3.3413.751613331.01.0123 3.3613.8519136 71 43.00.4215 5.4621.749214743.70.5014 5.4821.849414944.50.5313 5.5121.9497152 67 40.90.4415 5.4221.648613741.60.5113 5.4521.748913942.50.5512 5.4821.7492141 40.90.5619 5.4221.648713741.60.6318 5.4521.749013942.50.6716 5.4721.7492141 105°F 63 39.50.5718 5.4321.648412940.20.6417 5.4621.748713141.10.6816 5.4821.8490133 39.60.6922 5.4321.648512940.30.7721 5.4621.748813141.10.8020 5.4821.8490133 59 38.90.6420 5.4321.648312339.60.7119 5.4621.748612440.50.7518 5.4921.8489126 38.90.7724 5.4321.648312339.60.8423 5.4621.748612440.50.8822 5.4821.8489126 71 46.40.4016 4.9920.143914747.20.4715 5.0220.244214948.10.5113 5.0420.3445151 67 44.30.4115 4.9620.043413645.00.4914 4.9920.143713845.90.5213 5.0120.2440140 44.30.5420 4.9520.043413645.10.6118 4.9820.143713846.00.6517 5.0120.2440140 95°F 63 42.90.5419 4.9620.043212843.70.6218 4.9920.143513044.50.6516 5.0220.2438132 43.00.6723 4.9620.043212843.70.7422 4.9920.143513044.60.7821 5.0220.2438132 59 42.30.6221 4.9720.043112143.00.6920 5.0020.143412343.90.7318 5.0220.2437125 42.30.7425 4.9720.043112243.00.8124 4.9920.143412343.90.8523 5.0220.2437125 71 49.60.3817 4.5518.439014550.30.4515 4.5818.639314751.20.4914 4.6118.7396150 67 47.40.3916 4.5218.338513448.10.4615 4.5518.438813649.00.5013 4.5818.5391139 47.40.5220 4.5218.338513448.10.5919 4.5518.438813649.10.6218 4.5718.5391139Shaded area is ACCA (TVA) conditions Outdoor Ambient Temperature85°F Entering Indoor Wet Bulb Temperature63 46.00.5220 4.5318.338312646.70.5918 4.5618.438612847.60.6317 4.5818.6389130 46.00.6524 4.5318.338312646.70.7223 4.5618.438612847.60.7521 4.5818.5389130 59 45.30.5922 4.5318.338212046.00.6720 4.5618.538512247.00.7019 4.5918.6388124 45.30.7226 4.5318.338212046.10.7925 4.5618.538512247.00.8323 4.5818.6388124 71 51.90.3517 4.1316.634514252.60.4215 4.1616.834814553.50.4614 4.1916.9350147 67 49.60.3716 4.1016.533913250.40.4415 4.1316.634213451.30.4713 4.1516.7345136 49.70.4921 4.0916.533913250.40.5619 4.1216.634213451.30.6018 4.1516.7345136 75°F 63 48.20.4920 4.1016.533712349.00.5718 4.1416.634012649.90.6017 4.1616.8343128 48.20.6224 4.1016.533712449.00.6923 4.1316.634012649.90.7322 4.1616.7343128 59 48.30.5523 3.3813.634312048.30.6420 4.1416.733911949.20.6819 4.1716.8342122 48.30.6728 3.3713.534312048.30.7625 4.1416.733911949.20.8024 4.1616.8342122 71 53.40.3417 3.7414.930013854.10.4216 3.7715.130314155.10.4514 3.7915.2306143 67 51.10.3617 3.7014.829512851.90.4315 3.7314.929813052.80.4714 3.7615.0301132 51.10.4821 3.7014.729512851.90.5520 3.7314.929813052.80.5918 3.7515.0301132 65°F 63 49.60.4920 3.7114.829312050.40.5619 3.7414.929612251.30.5918 3.7715.1299124 49.70.6125 3.7014.829312050.40.6823 3.7414.929612251.40.7222 3.7615.0299124 59 41.80.5623 2.249.628011947.30.6122 2.7311.229311951.40.6421 3.1112.5304120 41.90.6828 2.249.628112047.30.7327 2.7311.229311951.50.7626 3.1012.5304120 MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR Airflow 1170 1380 1590 1170 1380 1590 70 75 IDB* IDB*: Entering Indoor Dry Bulb TemperatureHigh and low pressures are measured at the liquid and suction service valves.Airflow may vary depending on actual ambient conditions and system operation modes. 14 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 15 Expanded Cooling Data — DH6VSA4810A* / DFVE48DP1300A* (cont.) 71 33.20.6021 3.3413.752215833.80.6719 3.3613.852416034.50.7118 3.3713.8527163 33.80.7024 3.3513.752316034.40.771583.3613.852652235.10.8122 3.3713.9528165 67 31.50.7424 3.3213.651714732.10.8123 3.3413.752014932.80.8522 3.3513.8522151 32.20.8428 3.3313.751814932.70.911473.3413.752151733.40.9525 3.3613.8524153 115°F 63 30.40.8728 3.3313.751513931.00.9526 3.3413.751814131.70.9825 3.3613.8521143 31.11.0132 3.3313.751614031.61.011383.3513.751951532.31.0129 3.3613.8522144kW = Total system power Amps = outdoor unit amps 59 29.91.0130 3.3313.751413230.51.0128 3.3413.751713431.21.0127 3.3613.8519136 30.51.0133 3.3313.751513431.11.011323.3513.851851431.81.0131 3.3613.8521138 71 43.20.5420 5.4621.749214843.90.6218 5.4921.849515044.80.6517 5.5121.9498152 44.00.6423 5.4721.749315044.70.721475.5021.849649245.50.7521 5.5221.9499154 67 41.10.6823 5.4221.648713741.80.7622 5.4521.749013942.70.7921 5.4821.7493141 41.90.7827 5.4321.648813942.60.851375.4621.749148743.50.8924 5.4821.8494143 105°F 63 39.80.8127 5.4321.648512940.50.8925 5.4621.748813141.40.9224 5.4821.8491133 40.60.9130 5.4421.648613141.30.981295.4721.748948542.11.0128 5.4921.8492135 59 39.21.0129 5.4321.648412339.91.0127 5.4621.748712540.71.0126 5.4921.8490127 39.91.0132 5.4421.648512540.61.011235.4721.748848441.51.0130 5.5021.8491128 71 46.70.5220 4.9920.144014747.40.5919 5.0220.244314948.30.6318 5.0520.3446151 47.50.6224 5.0020.244114948.20.691475.0320.344444049.10.7321 5.0520.4447153 67 44.60.6624 4.9620.043513645.50.7323 5.0020.443714046.20.7721 5.0120.2441140 45.40.7528 4.9620.043613846.10.831364.9920.143943547.00.8625 5.0220.2442142 95°F 63 43.20.7928 4.9620.043312843.90.8626 4.9920.143613044.80.9025 5.0220.2439132 44.00.8931 4.9720.143413044.70.961285.0020.243743345.60.9929 5.0320.3440134 59 42.60.8629 4.9720.043212243.31.0028 5.0020.143412444.21.0027 5.0220.2437126 43.31.0033 4.9820.143312444.01.001225.0120.243643244.91.0031 5.0320.3439127 71 49.80.5021 4.5618.439114650.50.5720 4.5918.639414851.40.6118 4.6118.7397150 50.60.6025 4.5718.539214851.30.671454.6018.639539152.20.7022 4.6218.7398152 Shaded area is AHRI conditions 67 47.70.6425 4.5218.338613548.40.7123 4.5518.438913749.30.7422 4.5818.5392139 48.50.7329 4.5318.338713749.20.801344.5618.439038650.10.8426 4.5818.6393141 Outdoor Ambient Temperature85°F Entering Indoor Wet Bulb Temperature63 46.30.7628 4.5318.338412747.00.8427 4.5618.438712947.90.8726 4.5818.5390131 47.00.8632 4.5418.438512847.80.931264.5718.538838448.70.9730 4.5918.6391133 59 45.60.8430 4.5318.338312146.30.9129 4.5618.538612247.20.9928 4.5918.6388125 46.40.9934 4.5418.438412247.10.991204.5718.538738348.00.9932 4.6018.6390126 71 52.10.4721 4.1316.634514352.90.5420 4.1616.834814553.80.5818 4.1916.9351148 52.90.5725 4.1416.734614553.70.641424.1716.834934554.60.6822 4.2016.9352150 67 49.90.6125 4.0916.534013250.70.6824 4.1316.634313451.60.7222 4.1516.7346137 50.70.7029 4.1016.534113451.50.781324.1416.734434052.40.8126 4.1616.8347138 75°F 63 48.50.7429 4.1016.533812449.20.8127 4.1416.634112650.20.8426 4.1616.8344128 49.30.8333 4.1116.533912650.00.911244.1416.734233851.00.9430 4.1716.8345130 59 48.50.7833 3.3813.634312048.60.8829 4.1416.734012049.50.9228 4.1616.8343122 48.60.9935 4.1216.633812049.40.991204.1516.734134350.30.9932 4.1716.8344124 71 53.60.4622 3.7414.930113954.40.5320 3.7715.130414155.30.5719 3.8015.2307144 54.50.5626 3.7515.030214155.20.631383.7815.130530156.20.6723 3.8115.2308146 67 51.40.6026 3.7014.829612852.20.6724 3.7314.929913053.10.7123 3.7615.0302133 52.20.6930 3.7114.829713053.00.771283.7414.930029653.90.8027 3.7715.1303135 65°F 63 49.90.7329 3.7114.829412050.70.8028 3.7414.929712251.60.8327 3.7715.1300125 50.80.8233 3.7214.829512251.50.891203.7515.029829452.50.9331 3.7815.1301126 59 42.10.8033 2.249.628112048.50.8532 2.8311.529611951.70.8731 3.1112.5304121 48.50.9838 2.8211.429511951.60.981203.0912.430328151.80.9833 3.7815.1300120 MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR Airflow 1170 1380 1590 1170 1380 1590 80 85 IDB* IDB*: Entering Indoor Dry Bulb TemperatureHigh and low pressures are measured at the liquid and suction service valves.Airflow may vary depending on actual ambient conditions and system operation modes. 14 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 15 Expanded Cooling Data — DH6VSA6010A* / DFVE60DP1300A* 71 37.00.4816 5.1120.552616237.60.5615 5.1320.652916438.40.6014 5.1520.7532166 67 35.10.5016 5.0820.452115035.70.5714 5.1120.552415236.50.6113 5.1320.6527155 35.10.6220 5.0820.452215035.70.7019 5.1120.552515236.50.7417 5.1220.6527155 115°F 63 33.80.6319 5.0920.552014134.50.7118 5.1120.652214335.30.7417 5.1320.6525145 33.90.7623 5.0920.552014134.50.8322 5.1120.652314335.30.8721 5.1320.6525145kW = Total system power Amps = outdoor unit amps 59 33.30.7121 5.0920.551813333.90.7820 5.1220.652113534.70.8219 5.1420.7524137 33.30.8325 5.0920.551913333.91.0024 5.1120.652113534.71.0023 5.1320.6524137 71 46.60.4216 5.8923.749215247.40.4914 5.9223.849515448.30.5313 5.9523.9498156 67 44.30.4315 5.8623.548714145.10.5114 5.8923.748914346.00.5413 5.9123.8492145 44.40.5620 5.8523.548714145.10.6318 5.8923.649014346.10.6717 5.9123.7493145 105°F 63 42.90.5619 5.8723.648513243.60.6418 5.9023.748713444.60.6716 5.9223.8490136 42.90.6923 5.8623.548513243.70.7622 5.8923.748813444.60.8021 5.9223.8491136 59 42.20.6421 5.8723.648312443.00.7119 5.9023.748612643.90.7518 5.9323.8489128 42.20.7625 5.8723.648412443.00.8424 5.9023.748612643.90.8723 5.9223.8489128 71 54.50.3915 6.0024.145214855.30.4614 6.0324.345515056.40.5013 6.0624.4458152 67 52.00.4115 5.9623.944613752.80.4814 5.9924.145013953.90.5112 6.0224.2452141 52.00.5319 5.9523.944713752.90.6018 5.9924.145013953.90.6317 6.0224.2453141 95°F 63 50.40.5318 5.9724.044412851.20.6117 6.0024.144713052.30.6416 6.0324.3450132 50.40.6622 5.9624.044512851.20.7321 6.0024.144813052.30.7620 6.0324.3451132 59 49.60.6120 5.9724.044312150.40.6819 6.0124.244612251.50.7118 6.0424.3449125 49.60.7324 5.9724.044312150.50.8023 6.0024.144612251.50.8322 6.0324.3449125 71 57.90.3716 5.3321.339914458.80.4515 5.3721.540214659.80.4813 5.4021.6405148 67 55.40.3916 5.2921.139413356.20.4614 5.3321.339713557.30.4913 5.3621.4400137 55.40.5120 5.2921.139413356.20.5818 5.3221.339713557.30.6217 5.3521.4400137Shaded area is ACCA (TVA) conditions Outdoor Ambient Temperature85°F Entering Indoor Wet Bulb Temperature63 53.70.5219 5.3021.239212454.60.5918 5.3421.339512655.60.6217 5.3721.5398128 53.70.6423 5.3021.239212454.60.7122 5.3321.339512655.70.7421 5.3621.5398128 59 47.40.6022 4.0916.237111951.40.6721 4.5618.138011954.90.6918 5.3721.5396121 47.50.7227 4.0916.237111951.40.7925 4.5518.138111954.90.8223 5.3721.5397121 71 60.30.3516 4.7118.735013961.20.4215 4.7518.935314162.30.4613 4.7819.0356143 67 57.80.3616 4.6718.634512858.60.4314 4.7118.734813059.70.4713 4.7418.8351132 57.80.4920 4.6718.534512858.70.5618 4.7118.734813059.70.5917 4.7318.8351132 75°F 63 56.10.4919 4.6818.634312057.00.5618 4.7218.834612258.00.6017 4.7518.9349124 56.10.6123 4.6818.634312057.00.6822 4.7218.734612258.10.7221 4.7418.9349124 59 39.70.6021 2.6210.630811943.70.6620 2.9511.831511949.00.6919 3.4213.6326120 39.80.7326 2.6210.630811943.70.7925 2.9511.831512049.00.8224 3.4113.6326120 71 61.90.3416 4.1616.430413362.70.4215 4.1916.630713563.80.4514 4.2216.7310137 67 59.20.3616 4.1216.329812260.10.4314 4.1516.430112461.20.4613 4.1816.5304127 59.30.4820 4.1116.229912260.20.5519 4.1516.430212461.20.5918 4.1816.5305127 65°F 63 42.90.5120 2.459.926912047.60.5819 2.8011.227712053.30.6018 3.2612.9287120 42.90.6425 2.459.926912047.60.7123 2.7911.227712053.40.7322 3.2512.9287120 59 29.10.6720 1.606.525212132.00.7319 1.737.025612138.50.7219 2.108.5266119 29.10.8124 1.606.525212132.00.8723 1.737.025712138.50.8623 2.108.5266120 MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR Airflow 1390 1640 1890 1390 1640 1890 70 75 IDB* IDB*: Entering Indoor Dry Bulb TemperatureHigh and low pressures are measured at the liquid and suction service valves.Airflow may vary depending on actual ambient conditions and system operation modes. 16 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 17 Expanded Cooling Data — DH6VSA6010A* / DFVE60DP1300A* (cont.) 71 37.20.6120 5.1120.652716237.80.6819 5.1420.753016438.60.7218 5.1520.7532167 37.90.7124 5.1220.652816438.50.781625.1420.753152739.30.8222 5.1620.8534169 67 35.30.7524 5.0820.452215135.90.8223 5.1120.552515336.70.8622 5.1320.6528155 36.00.8528 5.0920.552315236.60.921505.1120.652652237.40.9625 5.1320.6529157 115°F 63 34.10.8827 5.0920.552014134.70.9626 5.1120.652314335.51.0025 5.1320.6526145 34.81.0031 5.1020.552214335.41.001415.1220.652452036.21.0029 5.1420.7527147kW = Total system power Amps = outdoor unit amps 59 33.51.0029 5.0920.551913334.11.0028 5.1220.652213534.91.0027 5.1420.7525137 34.21.0033 5.1020.552013534.81.001335.1220.652351935.61.0030 5.1420.7526139 71 46.90.5420 5.8923.749215247.60.6119 5.9223.849515548.60.6518 5.9523.9498157 47.70.6424 5.9023.749415448.40.711525.9323.949749249.40.7521 5.9624.0499159 67 44.60.6824 5.8623.548714145.40.7523 5.8923.749014346.30.7921 5.9123.8493146 45.50.7828 5.8723.648914346.20.851415.9023.749248747.20.8925 5.9223.8494147 105°F 63 43.20.8128 5.8623.648513243.90.8826 5.9023.748813444.90.9225 5.9223.8491137 44.00.9131 5.8723.648713444.71.001325.9123.749048545.71.0029 5.9323.8492138 59 42.51.0030 5.8723.648412543.21.0028 5.9023.748712744.21.0027 5.9223.8490129 43.31.0033 5.8823.648512644.11.001245.9123.748848445.01.0031 5.9323.9491130 71 54.80.5120 6.0024.145214855.60.5818 6.0324.345515056.60.6217 6.0624.4458153 55.70.6123 6.0124.245415056.50.681486.0524.345745257.60.7121 6.0724.5460154 67 52.30.6523 5.9623.944713753.50.7222 5.9424.044714154.20.7521 6.0224.2453142 53.20.7427 5.9724.044913954.00.811376.0024.145244755.10.8524 6.0324.3455143 95°F 63 50.70.7727 5.9724.044512851.50.8525 6.0024.144813052.60.8824 6.0324.3451133 51.60.8730 5.9824.044713052.40.941286.0124.245044553.50.9828 6.0424.3453134 59 49.90.8528 5.9724.044412150.81.0027 6.0124.244712351.81.0026 6.0324.3450125 50.81.0032 5.9824.044512351.71.001216.0224.244844452.71.0030 6.0524.3451127 71 58.20.4920 5.3321.340014459.00.5619 5.3721.540314660.10.6018 5.4021.6406149 59.10.5924 5.3421.440114660.00.661445.3821.540440061.00.7021 5.4121.7407150 Shaded area is AHRI conditions 67 55.70.6324 5.2921.139513356.50.7022 5.3321.339813557.60.7321 5.3621.4401138 56.60.7228 5.3021.239613557.50.791335.3421.339939558.50.8325 5.3721.5402139 Outdoor Ambient Temperature85°F Entering Indoor Wet Bulb Temperature63 54.00.7627 5.3021.239312554.90.8326 5.3421.339612755.90.8625 5.3721.5399129 55.00.8531 5.3121.239412655.80.921245.3521.439739356.90.9629 5.3821.5400131 59 47.70.8431 4.0916.237212054.10.9028 5.3421.439411955.20.9327 5.3721.5397122 54.21.0033 5.3221.339311955.01.001195.3521.439637256.11.0030 5.3821.5399123 71 60.60.4720 4.7218.735113961.50.5419 4.7518.935414162.60.5818 4.7819.0357144 61.60.5624 4.7318.835214162.40.641394.7618.935535163.50.6722 4.7919.1358146 67 58.10.6024 4.6718.634612959.00.6823 4.7118.734913160.00.7121 4.7418.8352133 59.00.7028 4.6818.634713059.90.771284.7218.835034661.00.8125 4.7518.9353135 75°F 63 56.40.7328 4.6818.634412057.30.8026 4.7218.834712258.40.8425 4.7518.9350124 57.40.8331 4.6918.634512258.20.901204.7318.834834459.30.9329 4.7618.9351126 59 40.00.8530 2.6210.630912043.90.9229 2.9511.831612051.60.9329 3.6714.6331119 44.01.0034 2.9311.831412049.21.001193.4013.532530955.91.0033 4.0716.1338119 71 62.20.4621 4.1616.430413363.00.5319 4.2016.630713564.10.5718 4.2316.7310138 63.10.5625 4.1716.530613564.00.631334.2116.630930465.10.6722 4.2416.8312140 67 59.60.6025 4.1216.329912360.40.6723 4.1516.430212561.50.7122 4.1816.5305127 60.50.6928 4.1316.330112461.40.771224.1616.530429962.50.8026 4.1916.6306129 65°F 63 45.00.7629 2.6010.427211950.30.8228 3.0112.028111957.20.8527 3.6014.2293119 50.40.8534 2.9911.928011953.50.911203.2412.828627260.80.9330 4.2016.6304120 59 31.70.9229 1.727.025411934.00.9828 1.837.525912040.10.9728 2.198.9268119 34.01.0033 1.827.425811938.61.001212.098.526525444.81.0032 2.5010.0275119 MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR MBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PRMBhS/T∆TkWAmpsHi PRLo PR Airflow 1390 1640 1890 1390 1640 1890 80 85 IDB* IDB*: Entering Indoor Dry Bulb TemperatureHigh and low pressures are measured at the liquid and suction service valves.Airflow may vary depending on actual ambient conditions and system operation modes. 16 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 17 Expanded Heating Data — Normal Heating Mode DH6VSA1810A* + DFVE24BP1300A* OUTDOOR AMBIENT TEMPERATURE 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 22.2 20.9 19.5 18.2 17.4 16.8 15.3 20.0 18.6 17.5 16.7 16.3 15.7 14.4 13.0 11.6 10.3 8.9 T/R 32 31 29 27 26 26 23 34 31 29 28 27 26 24 22 19 17 15 KW 1.79 1.74 1.68 1.63 1.59 1.57 1.52 2.28 2.20 2.12 2.05 2.00 1.97 1.89 1.82 1.74 1.66 1.58 AMPS 6.8 6.6 6.3 6.1 6.0 5.9 5.6 8.9 8.6 8.3 7.9 7.7 7.6 7.3 6.9 6.6 6.3 5.9 COP 3.64 3.52 3.41 3.29 3.20 3.13 2.95 2.57 2.47 2.41 2.39 2.39 2.34 2.23 2.10 1.96 1.81 1.64 DH6VSA2410A* + DFVE24BP1300A* OUTDOOR AMBIENT TEMPERATURE 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 29.5 27.7 26.0 24.3 23.2 22.4 20.4 22.8 21.0 19.7 18.7 18.2 17.6 15.9 14.2 12.5 10.8 9.2 T/R 33 31 30 28 27 26 24 25 23 22 21 20 19 17 16 14 12 10 KW 2.27 2.21 2.15 2.10 2.06 2.04 1.98 2.37 2.31 2.24 2.17 2.14 2.11 2.04 1.98 1.91 1.85 1.78 AMPS 8.6 8.3 8.1 7.8 7.7 7.6 7.3 9.0 8.8 8.5 8.2 8.0 7.9 7.6 7.3 7.0 6.8 6.5 COP 3.81 3.68 3.54 3.40 3.30 3.22 3.03 2.82 2.67 2.58 2.53 2.50 2.44 2.28 2.10 1.92 1.72 1.51 DH6VSA3010A* + DFVE36CP1300A* OUTDOOR AMBIENT TEMPERATURE 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 36.7 34.5 32.3 30.2 28.8 27.8 25.3 26.4 24.5 23.0 22.0 21.4 20.7 18.8 17.0 15.2 13.3 11.5 T/R 32 31 29 27 26 26 23 26 24 22 21 21 20 18 16 15 13 11 KW 2.83 2.75 2.68 2.60 2.56 2.53 2.45 2.85 2.77 2.69 2.61 2.56 2.53 2.45 2.37 2.29 2.21 2.13 AMPS 10.7 10.4 10.0 9.7 9.5 9.4 9.1 10.8 10.4 10.1 9.7 9.5 9.4 9.1 8.7 8.4 8.0 7.7 COP 3.80 3.67 3.54 3.40 3.30 3.22 3.02 2.71 2.59 2.51 2.47 2.45 2.40 2.25 2.10 1.94 1.76 1.58 DH6VSA3610A* + DFVE36CP1300A* OUTDOOR AMBIENT TEMPERATURE 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 43.6 41.1 38.6 36.2 34.6 33.4 30.7 32.8 30.1 28.1 26.7 26.0 25.0 22.5 20.0 17.5 15.0 12.6 T/R 31 29 28 26 25 25 23 22 20 19 18 18 17 15 14 12 10 9 KW 3.34 3.27 3.19 3.12 3.07 3.04 2.97 3.47 3.38 3.29 3.20 3.15 3.11 3.02 2.93 2.84 2.75 2.66 AMPS 12.5 12.2 11.9 11.6 11.4 11.2 10.9 13.1 12.7 12.3 11.9 11.7 11.5 11.1 10.7 10.3 10.0 9.6 COP 3.82 3.69 3.55 3.40 3.30 3.22 3.03 2.77 2.61 2.51 2.45 2.42 2.35 2.18 2.00 1.81 1.60 1.38 Calculations are based on nominal CFM and 70 °F indoor dry bulb. Amps = Outdoor unit amps (comp.+fan) Note: Shaded area is AHRI Rating Conditions at 47°F outdoor ambient temperature KW= Total system power 18 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 19 Expanded Heating Data — Normal Heating Mode DH6VSA4210A* + DFVE48DP1300A* OUTDOOR AMBIENT TEMPERATURE 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 47.0 45.1 43.2 41.3 40.0 39.0 37.2 41.9 39.2 36.9 35.4 34.5 33.4 30.6 27.8 25.0 22.2 19.4 T/R 32 31 30 29 28 28 26 33 31 29 28 27 26 24 22 20 17 15 KW 3.29 3.36 3.43 3.51 3.55 3.58 3.65 4.72 4.65 4.58 4.51 4.46 4.43 4.36 4.29 4.22 4.14 4.07 AMPS 13.0 13.3 13.6 14.0 14.2 14.3 14.6 18.3 17.8 17.2 16.6 16.3 16.1 15.5 17.4 14.4 13.8 13.2 COP 4.19 3.93 3.68 3.45 3.30 3.20 2.99 2.60 2.47 2.36 2.30 2.27 2.21 2.06 1.90 1.74 1.57 1.40 DH6VSA4810A* + DFVE48DP1300A* OUTDOOR AMBIENT TEMPERATURE 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 55.1 52.4 49.8 47.2 45.5 44.2 41.7 42.3 39.5 37.2 35.6 34.8 33.7 30.8 28.0 25.2 22.3 19.5 T/R 36 34 33 31 31 30 28 29 26 25 24 23 23 21 19 17 15 13 KW 4.02 4.02 4.03 4.04 4.04 4.04 4.05 4.51 4.44 4.37 4.30 4.26 4.24 4.17 4.10 4.03 3.96 3.89 AMPS 16.0 16.0 16.1 16.1 16.1 16.1 16.1 18.2 17.9 17.6 17.3 17.1 17.0 16.7 16.4 16.1 15.8 15.5 COP 4.02 3.82 3.62 3.43 3.30 3.21 3.02 2.75 2.60 2.49 2.43 2.39 2.33 2.17 2.00 1.83 1.65 1.47 DH6VSA6010A* + DFVE60DP1300A* OUTDOOR AMBIENT TEMPERATURE 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 69.0 64.9 60.9 57.0 54.5 52.7 48.2 53.3 49.0 45.9 43.7 42.5 40.9 37.0 33.0 29.0 25.1 21.1 T/R 37 36 34 32 31 30 27 29 27 25 24 23 22 20 18 16 14 12 KW 5.30 5.17 5.04 4.92 4.84 4.79 4.66 6.11 5.89 5.68 5.47 5.34 5.26 5.05 4.84 4.62 4.41 4.20 AMPS 20.4 19.9 19.3 18.8 18.4 18.2 17.7 23.9 23.0 22.1 21.2 20.6 20.3 19.3 18.4 17.5 16.6 15.7 COP 3.82 3.68 3.54 3.40 3.30 3.22 3.03 2.56 2.44 2.37 2.34 2.33 2.28 2.15 2.00 1.84 1.67 1.48 Calculations are based on nominal CFM and 70 °F indoor dry bulb. Amps = Outdoor unit amps (comp.+fan) Note: Shaded area is AHRI Rating Conditions at 47°F outdoor ambient temperature KW= Total system power 18 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 19 Expanded Heating Data — Heating Boost Mode DH6VSA1810A* + DFVE24BP1300A* OUTDOOR AMBIENT TEMPERATURE 65 60 55 50 47 45 40 35 or lower MBh 33.8 31.9 30.1 28.2 27.0 26.2 24.2 T/R 49 47 45 42 41 40 37 KW 2.81 2.73 2.65 2.57 2.52 2.49 2.41 Same as normal heating mode AMPS 11.2 10.9 10.5 10.2 10.0 9.9 9.5 COP 3.53 3.43 3.33 3.22 3.14 3.08 2.94 DH6VSA2410A* + DFVE24BP1300A* OUTDOOR AMBIENT TEMPERATURE 65 60 55 50 47 45 40 35 or lower MBh 34.0 32.1 30.1 28.2 27.0 26.1 23.9 T/R 38 36 34 32 31 30 28 KW 2.58 2.52 2.45 2.39 2.36 2.33 2.27 Same as normal heating mode AMPS 9.9 9.7 9.4 9.1 9.0 8.9 8.6 COP 3.87 3.74 3.60 3.45 3.35 3.28 3.08 DH6VSA3010A* + DFVE36CP1300A* OUTDOOR AMBIENT TEMPERATURE 65 60 55 50 47 45 40 35 or lower MBh 43.0 40.6 38.2 35.9 34.3 33.2 30.6 T/R 38 36 34 33 31 31 28 KW 3.28 3.20 3.12 3.04 3.00 2.96 2.89 Same as normal heating mode AMPS 12.6 12.3 12.0 11.6 11.4 11.3 10.9 COP 3.85 3.72 3.59 3.45 3.36 3.29 3.11 DH6VSA3610A* + DFVE36CP1300A* OUTDOOR AMBIENT TEMPERATURE 65 60 55 50 47 45 40 35 or lower MBh 48.0 45.1 42.4 39.6 37.9 36.6 33.4 T/R 34 32 31 29 28 27 25 KW 3.32 3.25 3.17 3.10 3.05 3.02 2.95 Same as normal heating mode AMPS 12.4 12.1 11.8 11.5 11.3 11.1 10.8 COP 4.23 4.08 3.91 3.75 3.63 3.54 3.32 Calculations are based on nominal CFM and 70 °F indoor dry bulb. Amps = Outdoor unit amps (comp.+fan) Note: Shaded area is AHRI Rating Conditions at 47°F outdoor ambient temperature KW= Total system power 20 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 21 Expanded Heating Data — Heating Boost Mode DH6VSA4210A* + DFVE48DP1300A* OUTDOOR AMBIENT TEMPERATURE 65 60 55 50 47 45 40 35 or lower MBh 63.9 60.4 57.0 53.6 51.4 49.7 46.0 T/R 48 46 44 41 40 39 36 KW 5.16 5.09 5.01 4.94 4.90 4.87 4.80 Same as normal heating mode AMPS 21.7 21.2 20.6 20.0 19.7 19.5 18.9 COP 3.63 3.48 3.33 3.18 3.07 2.99 2.81 DH6VSA4810A* + DFVE48DP1300A* OUTDOOR AMBIENT TEMPERATURE 65 60 55 50 47 45 40 35 or lower MBh 64.5 60.9 57.4 54.0 51.8 50.1 46.4 T/R 42 40 38 36 35 34 31 KW 4.93 4.86 4.79 4.72 4.68 4.65 4.58 Same as normal heating mode AMPS 20.0 19.7 19.4 19.1 18.9 18.8 18.5 COP 3.83 3.67 3.52 3.35 3.24 3.16 2.97 DH6VSA6010A* + DFVE60DP1300A* OUTDOOR AMBIENT TEMPERATURE 65 60 55 50 47 45 40 35 or lower MBh 81.1 76.4 71.7 67.2 64.2 62.0 56.8 T/R 44 42 40 38 36 35 32 KW 6.30 6.12 5.94 5.76 5.65 5.58 5.40 Same as normal heating mode AMPS 24.8 24.0 23.2 22.4 22.0 21.7 20.9 COP 3.77 3.66 3.54 3.42 3.33 3.26 3.09 Calculations are based on nominal CFM and 70 °F indoor dry bulb. Amps = Outdoor unit amps (comp.+fan) Note: Shaded area is AHRI Rating Conditions at 47°F outdoor ambient temperature KW= Total system power 20 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 21 Performance Data for Standard Operating Mode DH6VSA1810A* / DFVE24BP1300A* DH6VSA1810A* / DFVE24BP1300A* Design Subcooling @ AHRI 95°F Conditions 9-11°F Design Subcooling @ AHRI 95°F Conditions 9-11°F at 100% Demand in boost mode Outdoor Total Sensible Latent Total Outdoor Total Sensible Latent Total Temp °F BTU/h BTU/h BTU/h Watts Temp °F BTU/h BTU/h BTU/h Watts 75° 19,000 13,500 5,500 1,080 75° 20,500 14,800 5,700 1,100 80° 18,600 13,400 5,200 1,200 80° 20,000 14,600 5,400 1,200 85° 18,100 13,200 4,900 1,250 85° 19,500 14,400 5,100 1,300 90° 17,600 13,000 4,600 1,300 90° 18,900 14,200 4,700 1,400 95° 17,100 12,800 4,300 1,430 95° 18,300 13,900 4,400 1,450 100° 16,400 12,500 3,900 1,500 100° 17,600 13,600 4,000 1,600 105° 15,700 12,100 3,600 1,650 105° 16,900 13,200 3,700 1,700 110° 15,100 12,000 3,100 1,800 110° 16,300 13,100 3,200 1,800 115° 14,500 11,900 2,600 1,900 115° 15,700 13,000 2,700 1,950 TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB 95° 16,400 12,500 3,900 1,430 95° 17,600 13,600 4,000 1,450 DH6VSA2410A* / DFVE24BP1300A* DH6VSA2410A* / DFVE24BP1300A* Design Subcooling @ AHRI 95°F Conditions 11-13°F Design Subcooling @ AHRI 95°F Conditions 11-13°F at 100% Demand in boost mode Outdoor Total Sensible Latent Total Outdoor Total Sensible Latent Total Temp °F BTU/h BTU/h BTU/h Watts Temp °F BTU/h BTU/h BTU/h Watts 75° 26,000 18,200 7,800 1,790 75° 28,300 20,100 8,200 1,900 80° 25,400 18,000 7,400 1,900 80° 27,600 19,900 7,700 2,000 85° 24,700 17,800 6,900 2,030 85° 26,900 19,600 7,300 2,150 90° 24,000 17,500 6,500 2,200 90° 26,000 19,200 6,800 2,300 95° 23,200 17,200 6,000 2,270 95° 25,100 18,800 6,300 2,400 100° 22,200 16,600 5,600 2,400 100° 24,100 18,300 5,800 2,600 105° 21,100 16,000 5,100 2,570 105° 23,000 17,700 5,300 2,700 110° 20,300 15,900 4,400 2,700 110° 22,100 17,600 4,500 2,900 115° 19,400 15,700 3,700 2,910 115° 21,200 17,400 3,800 3,100 TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB 95° 22,200 16,700 5,500 2,290 95° 24,200 18,400 5,800 2,400 22 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 23 Performance Data for Standard Operating Mode (cont.) DH6VSA3010A* / DFVE36CP1300A* DH6VSA3010A* / DFVE36CP1300A* Design Subcooling @ AHRI 95°F Conditions 13-15°F Design Subcooling @ AHRI 95°F Conditions 13-15°F at 100% Demand in boost mode Outdoor Total Sensible Latent Total Outdoor Total Sensible Latent Total Temp °F BTU/h BTU/h BTU/h Watts Temp °F BTU/h BTU/h BTU/h Watts 75° 31,800 22,900 8,900 2,280 75° 34,700 24,600 10,100 2,350 80° 31,000 22,800 8,200 2,400 80° 33,900 24,500 9,400 2,500 85° 30,200 22,700 7,500 2,550 85° 33,000 24,400 8,600 2,600 90° 29,300 22,300 7,000 2,700 90° 31,900 23,900 8,000 2,800 95° 28,400 21,900 6,500 2,840 95° 30,700 23,300 7,400 2,900 100° 27,200 21,300 5,900 3,000 100° 29,500 22,800 6,700 3,100 105° 25,900 20,700 5,200 3,160 105° 28,200 22,300 5,900 3,250 110° 24,900 20,600 4,300 3,300 110° 27,100 22,100 5,000 3,400 115° 23,800 20,500 3,300 3,530 115° 26,000 21,800 4,200 3,600 TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB 95° 27,100 21,100 6,000 2,850 95° 29,600 22,800 6,800 2,900 DH6VSA3610A* / DFVE36CP1300A* DH6VSA3610A* / DFVE36CP1300A* Design Subcooling @ AHRI 95°F Conditions 14-16°F Design Subcooling @ AHRI 95°F Conditions 14-16°F at 100% Demand in boost mode Outdoor Total Sensible Latent Total Outdoor Total Sensible Latent Total Temp °F BTU/h BTU/h BTU/h Watts Temp °F BTU/h BTU/h BTU/h Watts 75° 38,300 28,000 10,300 3,050 75° 41,200 30,100 11,100 3,100 80° 37,300 27,600 9,700 3,200 80° 40,100 29,700 10,400 3,300 85° 36,300 27,200 9,100 3,430 85° 39,000 29,300 9,700 3,450 90° 35,300 26,800 8,500 3,600 90° 37,600 28,600 9,000 3,700 95° 34,200 26,300 7,900 3,800 95° 36,200 27,900 8,300 3,900 100° 32,500 25,300 7,200 4,100 100° 34,700 27,000 7,700 4,100 105° 30,800 24,300 6,500 4,310 105° 33,100 26,100 7,000 4,350 110° 29,800 24,600 5,200 4,400 110° 31,000 25,500 5,500 4,400 115° 28,800 24,800 4,000 4,390 115° 28,800 24,800 4,000 4,400 TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB 95° 32,500 25,400 7,100 3,850 95° 34,900 27,200 7,700 3,900 22 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 23 Performance Data for Standard Operating Mode (cont.) DH6VSA4210A* / DFVE48DP1300A* DH6VSA4210A* / DFVE48DP1300A* Design Subcooling @ AHRI 95°F Conditions 7-9°F Design Subcooling @ AHRI 95°F Conditions 7-9°F at 100% Demand in boost mode Outdoor Total Sensible Latent Total Outdoor Total Sensible Latent Total Temp °F BTU/h BTU/h BTU/h Watts Temp °F BTU/h BTU/h BTU/h Watts 75° 44,000 30,400 13,600 3,720 75° 47,600 31,900 15,700 3,100 80° 43,400 30,400 13,000 3,900 80° 47,000 31,900 15,100 3,300 85° 42,800 30,400 12,400 4,120 85° 46,300 31,900 14,400 3,450 90° 41,900 30,200 11,700 4,300 90° 45,300 31,700 13,600 3,600 95° 41,000 29,900 11,100 4,560 95° 44,200 31,400 12,800 3,800 100° 39,800 29,400 10,400 4,800 100° 42,900 30,900 12,000 4,000 105° 38,500 28,900 9,600 5,010 105° 41,600 30,400 11,200 4,150 110° 35,200 27,400 7,800 4,100 110° 36,800 28,100 8,700 3,700 115° 31,900 25,800 6,100 3,120 115° 31,900 25,800 6,100 3,150 TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB 95° 39,400 29,200 10,200 4,550 95° 42,600 30,700 11,900 3,800 DH6VSA4810A* / DFVE48DP1300A* DH6VSA4810A* / DFVE48DP1300A* Design Subcooling @ AHRI 95°F Conditions 8-10°F Design Subcooling @ AHRI 95°F Conditions 8-10°F at 100% Demand in boost mode Outdoor Total Sensible Latent Total Outdoor Total Sensible Latent Total Temp °F BTU/h BTU/h BTU/h Watts Temp °F BTU/h BTU/h BTU/h Watts 75° 50,700 34,500 16,200 4,130 75° 56,000 35,800 20,200 4,100 80° 49,600 34,500 15,100 4,300 80° 54,800 35,600 19,200 4,300 85° 48,400 34,400 14,000 4,550 85° 53,500 35,300 18,200 4,500 90° 47,000 33,800 13,200 4,800 90° 51,800 35,000 16,800 4,700 95° 45,500 33,200 12,300 5,000 95° 50,100 34,600 15,500 4,950 100° 43,700 32,500 11,200 5,200 100° 48,200 33,800 14,400 5,200 105° 41,800 31,800 10,000 5,450 105° 46,300 32,900 13,400 5,400 110° 37,000 28,900 8,100 4,400 110° 39,200 29,500 9,700 4,400 115° 32,100 26,000 6,100 3,340 115° 32,100 26,000 6,100 3,350 TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB 95° 43,700 32,300 11,400 4,990 95° 48,300 33,300 15,000 4,950 24 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 25 Performance Data for Standard Operating Mode (cont.) DH6VSA6010A* / DFVE60DP1300A* DH6VSA6010A* / DFVE60DP1300A* Design Subcooling @ AHRI 95°F Conditions 8-10°F Design Subcooling @ AHRI 95°F Conditions 8-10°F at 100% Demand in boost mode Outdoor Total Sensible Latent Total Outdoor Total Sensible Latent Total Temp °F BTU/h BTU/h BTU/h Watts Temp °F BTU/h BTU/h BTU/h Watts 75° 59,000 40,100 18,900 4,710 75° 65,000 42,300 22,700 5,950 80° 57,800 39,900 17,900 5,000 80° 63,700 42,000 21,700 6,350 85° 56,500 39,600 16,900 5,330 85° 62,300 41,700 20,600 6,700 90° 55,000 39,100 15,900 5,600 90° 59,900 41,000 18,900 6,950 95° 53,500 38,500 15,000 5,940 95° 57,500 40,300 17,200 7,300 100° 49,500 36,300 13,200 5,900 100° 51,500 37,200 14,300 6,550 105° 45,400 34,100 11,300 5,890 105° 45,400 34,000 11,400 5,900 110° 40,700 31,800 8,900 5,500 110° 40,700 31,800 8,900 5,550 115° 35,900 29,400 6,500 5,110 115° 35,900 29,500 6,400 5,150 TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB TVA Conditions @ 95° OD DB, 75° ID, 63° ID WB 95° 51,200 37,400 13,800 6,000 95° 55,400 39,300 16,100 7,300 24 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 25 Sound Data - Sound Power Normal mode - Cooling Sound Power Level1 Octave Band Spectrum Frequency (Hz) Analysis (dB) Total Unit Tonnage Sound Rating (dBA) 125 250 500 1000 2000 4000 8000 1.5-ton 61 47.7 53.0 56.9 54.8 48.4 41.2 36.5 2-ton 64 47.8 57.9 60.7 55.8 48.9 43.4 39.1 2.5-ton 66 56.9 57.4 62.0 60.2 54.2 47.4 40.3 3-ton 68 55.9 59.6 63.9 61.0 56.5 53.4 45.4 3.5-ton 70 59.7 63.9 64.6 65.2 60.3 53.8 47.5 4-ton 72 63.5 64.9 65.6 65.4 60.4 55.8 48.8 5-ton 71 61.2 64.7 65.3 65.6 61.3 57.2 48.9 1 Compliant with AHRI 270. 2 Compliant with AHRI 220. Normal mode - Heating Sound Power Level1 Octave Band Spectrum Frequency (Hz) Analysis (dB) Total Unit Tonnage Sound Rating (dBA) 125 250 500 1000 2000 4000 8000 1.5-ton 61 48.4 52.3 57.3 54.9 48.7 44.8 40.4 2-ton 63 49.7 55.7 58.6 56.3 50.8 48.6 40.1 2.5-ton 70 56.2 61.4 65.5 64.5 58.4 52.0 44.6 3-ton 71 57.9 62.7 65.6 65.3 59.5 57.6 47.9 3.5-ton 71 60.7 61.3 64.8 66.1 61.5 56.0 50.3 4-ton 71 58.8 62.3 66.0 66.4 61.8 56.8 50.6 5-ton 72 61.0 64.2 66.6 66.7 62.2 57.0 51.3 1 Compliant with AHRI 270. 2 Compliant with AHRI 220. 26 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 27 Sound Data - Quiet mode Quiet mode_Cooling Sound suppression Sound Power Level Sound Pressure Level Tonnage level (dBA)1 (dBA)2 LV.1 63 46 1.5-ton LV.2 60 43 LV.3 57 40 LV.1 64 47 2-ton LV.2 61 44 LV.3 58 41 LV.1 65 51 2.5-ton LV.2 62 48 LV.3 59 45 LV.1 65 51 3-ton LV.2 62 48 LV.3 59 45 LV.1 67 55 3.5-ton LV.2 62 50 LV.3 57 45 LV.1 67 55 4-ton LV.2 62 50 LV.3 57 45 LV.1 68 55 5-ton LV.2 63 50 LV.3 58 45 1 Quiet Mode Sound Power and Sound Pressure levels determined at a distance of 3 [ft]. Quiet mode_Heating Sound suppression Sound Power Level Sound Pressure Level Tonnage level (dBA)1 (dBA)2 LV.1 65 48 1.5-ton LV.2 62 45 LV.3 59 42 LV.1 66 49 2-ton LV.2 63 46 LV.3 60 43 LV.1 67 53 2.5-ton LV.2 64 50 LV.3 59 45 LV.1 67 53 3-ton LV.2 64 50 LV.3 59 45 LV.1 67 55 3.5-ton LV.2 62 50 LV.3 57 45 LV.1 67 55 4-ton LV.2 62 50 LV.3 57 45 LV.1 68 55 5-ton LV.2 63 50 LV.3 58 45 1 Quiet Mode Sound Power and Sound Pressure levels determined at a distance of 3 [ft]. 26 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 27 Sound Data - Sound Pressure Sound Level Distance Measurement Outdoor Unit Reflective Surface 3’ ft. (Back wall) 15’ ft. 9’ ft. 7’ ft. 5’ ft. Sound Pressure (dBA) Cooling Mode1 Distance From Property Line Tonnage Reflective Surface Qty. 3' 5' 7' 9' 15' 0 53 49 46 44 39 1.5 Ton 1 56 52 49 47 42 2 59 55 52 50 45 0 56 52 49 47 42 2.0 Ton 1 59 55 52 50 45 2 62 58 55 53 48 0 59 54 52 49 45 2.5 Ton 1 62 57 55 52 48 2 65 60 58 55 51 0 60 56 53 51 46 3.0 Ton 1 63 59 56 54 49 2 66 62 59 57 52 0 63 59 56 54 49 3.5 Ton 1 66 62 59 57 52 2 69 65 62 60 55 0 64 60 57 55 50 4.0 Ton 1 67 63 60 58 53 2 70 66 63 61 56 0 64 60 57 55 50 5.0 Ton 1 67 63 60 58 53 2 70 66 63 61 56 1 Compliant with AHRI 275 utilizing standard mode, total sound levels Sound Pressure (dBA) Heating Mode1 Distance From Property Line Tonnage Reflective Surface Qty. 3' 5' 7' 9' 15' 0 54 49 46 44 40 1.5 Ton 1 57 52 49 47 43 2 60 55 52 50 46 0 55 51 48 46 41 2.0 Ton 1 58 54 51 49 44 2 61 57 54 52 47 0 62 58 55 53 48 2.5 Ton 1 65 61 58 56 51 2 68 64 61 59 54 0 63 59 56 54 49 3.0 Ton 1 66 62 59 57 52 2 69 65 62 60 55 0 63 59 56 54 49 3.5 Ton 1 66 62 59 57 52 2 69 65 62 60 55 0 64 60 57 54 50 4.0 Ton 1 67 63 60 57 53 2 70 66 63 60 56 0 65 61 58 55 51 5.0 Ton 1 68 64 61 58 54 2 71 67 64 61 57 1 Compliant with AHRI 275 utilizing standard mode, total sound levels 28 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 29 AHRI All AHRI system ratings are accessible in the Unitary Matchup Tool via Daikin City or in the Daikin System Configurator tool via PartnerLink. 28 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 29 Dimensions Dimensions Model W" D" H" DH6VSA1810A* 36⅝ 13¾ 27⅜ DH6VSA2410A* 36⅝ 13¾ 27⅜ DH6VSA3010A* 36⅝ 13¾ 27⅜ DH6VSA3610A* 36⅝ 13¾ 27⅜ 30 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 31 Dimensions Dimensions Model W" D" H" DH6VSA4210A* 37 12⅝ 39 DH6VSA4810A* 37 12⅝ 39 DH6VSA6010A* 37 12⅝ 39 30 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 31 Wiring Diagram — DH6VSA1810/2410/3010/3610A* ⚡ Disconnect all power before servicing or installing this unit. Multiple power High Voltage:sources may be present. Failure to do so may cause property damage, personal injury, or death. Warning ⚠ Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 32 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 33 Wiring Diagram — DH6VSA4210/4810/6010A* ⚡ Disconnect all power before servicing or installing this unit. Multiple power High Voltage:sources may be present. Failure to do so may cause property damage, personal injury, or death. Warning ⚠ Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 32 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 33 Accessories DH6VSA DH6VSA DH6VSA DH6VSA DH6VSA DH6VSA DH6VSA Model Description 1810A* 2410A* 3010A* 3610A* 4210A* 4810A* 6010A* KPW5G112 Wind Baffle X X X X X X X KPS00501 ¹ Snow Guard Front X X X X KPS00502 ¹ Snow Guard Rear X X X X KPS00503 ¹ Snow Guard Side X X X X KPS00504 ¹ Snow Guards - Complete Set X X X X KPS00601 ¹ Snow Guard Front X X X KPS00602 ¹ Snow Guard Rear X X X KPS00603 ¹ Snow Guard Side X X X KPS00604 ¹ Snow Guards - Complete Set X X X 130-DK-006 Hail Guard X X X X 130-DK-008 Hail Guard X X X KEH3P573598 Drain Pan Heater X X X X KEH3P573567 Drain Pan Heater X X X DACA-WB-3 Powder Coated Wall-Mounted Bracket X X X X X X X DSEN-HAQA Daikin One Home Air Monitor X X X X X X X DQ-P-16-100 Daikin One Powered Ventilator X X X X X X X ¹ Product is manufactured at time of order. Lead time will be associated with purchase. 34 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 35 Notes Quiet mode - Heating Tonnage Sound suppression level Sound Power Level (dBA)1 Sound Pressure Level (dBA)2 LV.1 65 48 1.5-ton LV.2 62 45 LV.3 59 42 LV.1 66 49 2-ton LV.2 63 46 LV.3 60 43 LV.1 67 53 2.5-ton LV.2 64 50 LV.3 59 45 LV.1 67 53 3-ton LV.2 64 50 LV.3 59 45 LV.1 67 55 3.5-ton LV.2 62 50 LV.3 57 45 LV.1 67 55 4-ton LV.2 62 50 LV.3 57 45 LV.1 68 55 5-ton LV.2 63 50 LV.3 58 45 1Compliant with ISO3744. 2Compliant with JIS B 8616 : 2006. 34 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com 35 Notes Our continuing commitment to quality products may mean a change in specifications without notice. ©2024 • Houston, Texas • Printed in the USA. 36 www.daikincomfort.com SS-DH6VS-R32 SS-DH6VS-R32 www.daikincomfort.com PB Permit #: 6398 Permit Date: 03/04/25 Permit Type: RESIDENTIAL MECHANICAL Project Name: LEATHERMAN MECH PERMIT Applicant Name: CM HEATING Applicant Address: 1500 INDUSTRY ST Applicant, City, State, Zip: EVERETT Contact: SABRINA KENNARD Phone: 4252590550 Email: PERMITS@CMHEATING.COM Scope of Work: GAS FURNACE SWAP WITH HEAT PUMP ADD Valuation: 17279.00 Square Feet: 1412 Number of Stories: 1 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 03/06/2025 Permit Expires: 09/05/2025 Form Permit Type: RESIDENTIAL MECHANICAL Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 100 SINGLE ROBB RONALD J 00832900006500 7605 EAGLEFIELD DR FAMILY & LAURA L RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License # 1500 INDUSTRY CONSTRUCTION Plumbing CM HEATING INC 425-259-0550 CMHEAHL750LP ST STE 200 CONTRACTOR Contractor 1500 INDUSTRY CONSTRUCTION Construction CM HEATING INC 425-259-0550 CMHEAHL751W ST STE 200 CONTRACTOR Contractor 1500 INDUSTRY CONSTRUCTION CM HEATING INC 425-259-0550 UBI 605890285 ST STE 200 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status R00. HEAT PUMP / 09/03/2025 09/04/2025 09/05/2025 BUILDING Approved AC UNIT FINAL R08. Please check the proposed 03/04/2025 MECHANICAL Heat Pump location. Setback 03/05/2025 03/05/2025 BUILDING Approved ROUGH-IN concern. Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Forced Air Heat ≤ 100 BTU/h Enter # of units $15.00 Heat Pump - Condensing Unit Enter # of units $25.00 Mechanical Base Permit Fee $25.00 Credit Card Service $4.95 Total $169.95 Attached Letters Date Letter Description 03/05/2025 Building Permit 03/04/2025 Web Form- Residential Mechanical Application Payments Date Paid By Description Payment Type Accepted By Amount 03/04/2025 Douglas Perera 224864349 Hannah Hardwick $4.95 XBP Conf: 03/04/2025 $165.00 224864349 Outstanding Balance $0.00 Notes Date Note Created By: 08/28/2025 sent expiration notice Hannah Hardwick 07/25/2025 sent expiration notice Hannah Hardwick Uploaded Files Date File Name 03/06/2025 24802572-2025_BLD6398_IssuedPermit.pdf 03/04/2025 fa171f6de5367e6d813706f79adf0389_leatherman_site_plan.pdf 03/04/2025 ce774cd14d32aae1fd49d485d58f9189_leatherman_app.pdf 03/04/2025 e9ad438de8d0fdfeb00c4dc4d01cd2e1_ss-dh6vs-r32_1_.pdf