Loading...
HomeMy WebLinkAbout6205_BLD6410_2025 PERMIT FEE WAIVER REQUEST Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 PER THE CURRENT FEE RESOLUTION Section 1. Fees and Charges—General. 1.1 Fees. Fees are intended to cover the normal, recurring costs associated with providing a given service. Fees are non-refundable. 1.2 Prices. In some instances, the City provides certain goods and merchandise for sale. Prices for these goods may be included in this resolution. 1.3 Payment Due. Fees are due at the time the action is requested (e.g., at time of application) or occurs (e.g., prior to a specific action). An applicant may pay all fees of a multi-phased project in advance; however, doing so does not vest applicable fees due. Fees due are those in effect at the time the specific action or phase of an action is requested or occurs. 1.4 Waivers. Upon petition by the applicant, the City Council may waive any of the fees, or portions thereof, for any non-profit organization or government agency. NOTE: State Surcharge Fees cannot be waived. Permit Number: Total Amount: $ Staff Requesting Fee Waiver: Staff Department: Staff Email: Staff Phone #: Reason for Waiver: Council Workshop Date: Council Approval Date: Signatory Authority: Print Name: CED STAFF USE ONLY FEE BREAKDOWN Plan Review Fee(s) $ Permit Fee(s) $ Processing Technology Fee $ State Surcharge Fee $ Other: $ Other: $ ACCEPTED BY DATE STAMP REV5.2021 Page 1 of 1 www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ® ICC-ES Evaluation Report Reissued May 2023 ESR-1388 Revised August 2023 This report is subject to renewal May 2024. DIVISION: 07 00 00—THERMAL AND MOISTURE 3.2 Membranes: PROTECTION 3.2.1 Flintlastic FR Cap 30 (Standard or CoolStar): Section: 07 52 00—Modified Bituminous Sheet Roofing Flintlastic FR Cap 30 is a 0.138-inch-thick (3.5 mm), granular-surfaced, reinforced, SBS modified bitumen REPORT HOLDER: roofing membrane manufactured from a glass fiber mat impregnated and covered with SBS modified bitumen. The CERTAINTEED LLC membrane is a Type I, Grade G, membrane complying with ASTM D6163 and intended for adhesive or hot EVALUATION SUBJECT: asphalt application. The membrane weighs approximately CERTAINTEED FLINTLASTIC MODIFIED BITUMEN 7.2 pounds per square yard (3.9 kg/m2). The membrane is also available as a CoolStar option, which utilizes bright ROOF COVERING SYSTEMS white granules. 1.0 EVALUATION SCOPE 3.2.2 Flintlastic FR-P (Standard or CoolStar): Flintlastic FR-P is a 0.17-inch-thick (4.3 mm), granular-surfaced, Compliance with the following codes: reinforced, SBS modified bitumen roofing membrane  2021, 2018, 2015, 2012 and 2009 International Building manufactured from a nonwoven polyester fabric Code® (IBC) impregnated and covered with SBS modified bitumen. The  2021, 2018, 2015, 2012 and 2009 International membrane is a Type I, Grade G, membrane complying Residential Code® (IRC) with ASTM D6164 and intended for adhesive or hot asphalt application. The membrane weighs approximately Properties evaluated: 8.4 pounds per square yard (4.6 kg/m2). The membrane is  Fire classification also available as a CoolStar option, which utilizes bright white granules.  Wind uplift resistance 3.2.3 Flintlastic Premium FR-P (Standard or  Physical properties CoolStar): Flintlastic Premium FR-P is a 0.17-inch-thick  Impact resistance (4.3 mm), mineral-surfaced, reinforced, SBS modified bitumen roofing membrane manufactured from a 2.0 USES nonwoven polyester fabric impregnated and covered with The CertainTeed Flintlastic modified bitumen roof covering SBS modified bitumen. The membrane is a Type II, membranes are used as roof coverings in Class A, B or C Grade G, membrane complying with ASTM D6164 and roof covering systems, described in this report, on new or intended for adhesive or hot asphalt application. The existing roofs. membrane weighs approximately 8.4 pounds per square yard (4.6 kg/m2). The membrane is also available as a 3.0 DESCRIPTION CoolStar option, which utilizes bright white granules. 3.1 General: 3.2.4 Flintlastic GTS (Standard or CoolStar): Flintlastic CertainTeed roofing membranes are atactic polypropylene GTS is a 0.176-inch-thick (4.5 mm), granular-surfaced, (APP) or styrene butadiene styrene (SBS) modified reinforced, SBS modified bitumen roofing membrane bitumen membranes complying with ASTM D6222, ASTM manufactured from a nonwoven polyester fabric D6162, ASTM D6163 or ASTM D6164, as applicable. Roof impregnated and covered with SBS modified bitumen. The covering systems utilizing CertainTeed roofing membranes membrane is a Type II, Grade G, membrane complying consist of single-ply membranes, base sheets and ply with ASTM D6164 and intended for torch application only. sheets, approved insulation, flashing, asphalts, adhesives, The membrane weighs approximately 9.9 pounds per coatings and mechanical fasteners that are installed to square yard (5.4 kg/m2). The membrane is also available produce an integrated roof system. as a CoolStar option, which utilizes bright white granules. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2023 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 28 ESR-1388 | Most Widely Accepted and Trusted Page 2 of 28 3.2.5 Flintlastic GMS (Standard or CoolStar): with ASTM D6163 and is intended for self-adhered Flintlastic GMS is a 0.17-inch-thick (4.3 mm), granular- application only. The membrane weighs approximately surfaced, reinforced, SBS modified bitumen roofing 7.3 pounds per square yard (4.0 kg/m2). The membrane is membrane manufactured from a nonwoven polyester fabric also available as a CoolStar option, which utilizes bright impregnated and covered with SBS modified bitumen. white granules. The membrane is a Type I, Grade G, membrane 3.2.12 Flintlastic SA Cap (Standard or CoolStar): complying with ASTM D6164 and intended for adhesive Flintlastic SA Cap is a 0.16-inch-thick (4.0 mm), granular- or hot asphalt application. The membrane weighs surfaced, reinforced, SBS modified bitumen roofing approximately 8.0 pounds per square yard (4.4 kg/m2). membrane manufactured from a non-woven polyester/fiber The membrane is also available as a CoolStar option, glass scrim combination mat, impregnated and coated with which utilizes bright white granules. a superior grade of modified bitumen compound. The 3.2.6 Flintlastic Premium GMS (Standard or CoolStar): membrane is a Type I, Grade G membrane complying with Flintlastic Premium GMS is a 0.17-inch-thick (4.3 mm), ASTM D6164 and is intended for self-adhered application granular-surfaced, reinforced, SBS modified bitumen only. The membrane weighs approximately 95 pounds per roofing membrane manufactured from a nonwoven roll. The membrane is also available as a CoolStar option, polyester fabric impregnated and covered with SBS which utilizes bright white granules. modified bitumen. The membrane is a Type II, Grade G, 3.2.13 Flintlastic FR Cap 30 T (Standard or CoolStar): membrane complying with ASTM D6164 and intended for Flintlastic FR Cap 30 T is a 0.15-inch-thick (3.8 mm), adhesive or hot asphalt application. The membrane weighs granular-surfaced, reinforced, SBS modified bitumen approximately 8.4 pounds per square yard (4.6 kg/m2). The roofing membrane manufactured from a glass fiber mat membrane is also available as a CoolStar option, which impregnated and covered with SBS modified bitumen. utilizes bright white granules. The membrane is a Type I, Grade G membrane complying 3.2.7 Flintlastic STA: Flintlastic STA is a 0.16-inch-thick with ASTM D6163 and is intended for torch application (4 mm), smooth-talc-surfaced, reinforced, APP modified only. The membrane weighs approximately 8.1 pounds per bitumen roofing membrane. Flintlastic STA is used as a square yard (4.4 kg/m2). The membrane is also available cap sheet or ply sheet and is manufactured from a as a CoolStar option, which utilizes bright white granules. nonwoven polyester fabric impregnated and covered with 3.3 Insulation: APP modified bitumen. The membrane is a Type I, Grade S, membrane complying with ASTM D6222 and Foam plastic insulation, where used, must have a intended for torch application only. The membrane weighs flame-spread index of not more than 75 when tested, at the approximately 7.4 pounds per square yard (4.0 kg/m2). maximum thickness intended for use, in accordance with UL 723 or ASTM E84. See Tables 1A, 1C and 2A through 3.2.8 Flintlastic STA Plus: Flintlastic STA Plus is a 2F for insulations permitted for use with specific roofing 0.18-inch-thick (4.5 mm), smooth-talc-surfaced, reinforced, systems. APP modified bitumen roofing membrane. The membrane is used as a cap sheet or ply sheet and is manufactured 3.4 Fasteners: from a nonwoven polyester fabric impregnated and Fasteners and plates used to mechanically fasten covered with APP modified bitumen. The membrane is a insulation and base sheets must be in accordance with Type I, Grade S, membrane complying with ASTM D6222 Table 3 unless otherwise noted. and intended for torch application only. The membrane weighs approximately 8.1 pounds per square yard 3.5 Adhesives: (4.4 kg/m2). See Table 2F, footnote 5, for adhesives and coverage 3.2.9 Flintlastic GTA (Standard or CoolStar): Flintlastic rates. GTA is a 0.16-inch-thick (4 mm), granular-surfaced, 3.6 Impact Resistance: reinforced, APP modified bitumen roofing membrane manufactured from a nonwoven polyester fabric The CertainTeed Flintlastic modified bitumen roof impregnated and covered with APP modified bitumen. The coverings described in this report meet the requirement membrane is a Type I, Grade G, membrane complying for impact resistance in accordance with Section 4.6 of with ASTM D6222 and intended for torch application only. FM 4470. The membrane weighs approximately 7.8 pounds per 4.0 INSTALLATION square yard (4.2 kg/m2). The membrane is also available 4.1 General: as a CoolStar option, which utilizes bright white granules. Installation of the CertainTeed Flintlastic membrane roof 3.2.10 Flintlastic GTA-FR (Standard or CoolStar): covering systems described in this report must comply Flintlastic GTA-FR is a 0.160-inch-thick (4.1 mm), with the applicable code, the manufacturer’s published granular-surfaced, reinforced, APP modified bitumen installation instructions and this report. The manufacturer’s roofing membrane manufactured from a nonwoven published installation instructions must be available at all polyester fabric impregnated and covered with APP times on the jobsite during installation. CertainTeed modified bitumen. The membrane is a Type I, Grade G, Flintlastic roofing membranes are components of roof membrane complying with ASTM D6222 and intended for covering systems that may be installed over new or torch application only. The membrane weighs 2 existing roofs as described in Tables 1A through 1D and approximately 8.6 pounds per square yard (4.7 kg/m ). 2A through 2F. The membrane is also available as a CoolStar option, which utilizes bright white granules. The roof slope must be a minimum of 1/4:12 (2 percent slope) and must not be more than maximum slope for the 3.2.11 Flintlastic SA Cap-FR (Standard or CoolStar): particular system as specified in Tables 1A through 1D. Flintlastic SA Cap FR is a 0.125-inch-thick (3.2 mm), granular-surfaced, reinforced, SBS modified bitumen Penetrations and terminations of the roof covering must roofing membrane manufactured from a glass fiber mat be flashed and made weathertight in accordance with the impregnated and covered with SBS modified bitumen. CertainTeed LLC’s published installation instructions and The membrane is a Type I, Grade G membrane complying the applicable code. ESR-1388 | Most Widely Accepted and Trusted Page 3 of 28 4.2 Fire Classification: 5.4 Foam plastic insulation, where used, must bear the label of an approved agency indicating that the foam 4.2.1 New Construction: Roof covering systems plastic has a flame-spread index of not more than 75 described in Tables 1A through 1D, when installed in when tested at the maximum thickness intended for accordance with this report, are Class A, B or C roof use in accordance with ASTM E84 or UL 723, subject coverings in accordance with ASTM E108 or UL 790. to the approval of the code official. Except for 4.2.2 Reroofing: Prior to installation of new roof applications where a thermal barrier is not required, coverings, inspection in accordance with 2021 IBC Section total thickness of foam plastic insulation must be 1512 [2018 IBC Section 1511 (2015, 2012 and 2009 IBC limited to the lesser of the maximum thickness Section 1510)] and 2018 IRC Section R908 [2015, 2012 allowed in Tables 1A, 1C and 2A through 2F or the and 2009 IRC Section R907], and approval from the code maximum thickness that limits the flame-spread index official having jurisdiction, are required. to not more than 75 when testing is in accordance Class A, B or C roof covering systems may be installed with ASTM E84 or UL 723, subject to the approval of over existing roof coverings without additional roof the code official. classification tests, provided the resulting classification is 5.5 Design wind uplift pressure on any roof area, the lower of the new and existing roofing classifications including edge and corner zones, must not exceed under the following conditions: the allowable wind uplift pressure for the roof covering  New uninsulated systems installed only over existing installed in that particular area. Refer to allowable uninsulated systems wind uplift pressure shown in Tables 2A through 2F.  New insulated systems installed over existing 5.6 Above-deck thermal insulation board must comply uninsulated systems only with the applicable standards listed in IBC Table 1508.2 and IRC Table R906.2. 4.3 Wind Uplift Resistance: 5.7 The allowable wind-uplift pressures shown in 4.3.1 New Construction: The CertainTeed Flintlastic Tables 2A through 2F are for the roof covering only. membrane roof covering systems described in this report The deck and framing to which the roof covering is have a maximum allowable wind uplift capacity as shown attached must be designed for the applicable in Tables 2A through 2F. Metal edge securement systems components, and cladding wind loads in accordance must be listed in accordance with the 2017 edition of with the applicable code. ANSI/SPRI/FM4435 ES-1, and designed and installed in accordance with 2021 IBC Section 1504.6 and 2021 IBC 5.8 Calculations demonstrating that the required wind Chapter 16 [2011 edition of ANSI/SPRI/FM4435 ES-1, and resistance is less than the allowable wind resistance designed and installed in accordance with 2018 and 2015 must be submitted to the code official. IBC Section 1504.5 and 2018 and 2015 IBC Chapter 16 5.9 When application is over existing roofs, (2003 edition of ANSI/SPRI ES-1, and designed and documentation of the wind-uplift resistance of the installed in accordance with 2012 and 2009 IBC Section composite roof construction must be submitted to 1504.5 and 2012 and 2009 IBC Chapter 16)]. the code official at the time of permit application. 4.3.2 Reroofing: Roof covering systems employing mechanical fasteners must be qualified, to the satisfaction 5.10 The membranes are manufactured in Little Rock, of the code official, on adequacy of fasteners penetrating Arkansas, under quality control programs with through existing roof coverings into structural substrates. inspections by ICC-ES. Since the composition and/or condition of any particular 6.0 EVIDENCE SUBMITTED underlying existing roofing material can vary widely, reroofing with adhered systems is outside the scope of this Data in accordance with the ICC-ES Acceptance Criteria report. for Membrane Roof-covering Systems (AC75), dated July 2010 (editorially revised April 2021). 5.0 CONDITIONS OF USE 7.0 IDENTIFICATION The CertainTeed Flintlastic membrane roof covering systems described in this report comply with, or are 7.1 The ICC-ES mark of conformity, electronic labeling, or suitable alternatives to what is specified in, those codes the evaluation report number (ICC-ES ESR-1388) listed in Section 1.0 of this report, subject to the following along with the name, registered trademark, or conditions: registered logo of the report holder must be included in the product label. 5.1 Installation must comply with the applicable code, the manufacturer’s published installation instructions and 7.2 In addition, each roll of CertainTeed Flintlastic roofing this report. If there are any conflicts between the membranes covered by this report is labeled with the manufacturer’s published installation instructions and CertainTeed LLC address, product name, and date this report, this report governs. code. 5.2 Foam plastic insulation must be separated from the 7.3 The report holder’s contact information is the interior of the building by an approved thermal barrier following: in accordance with IBC Section 2603.4.1.5 and IRC Section R316.5.2, except when specifically listed in CERTAINTEED LLC an ICC-ES evaluation report as outlined in Footnote 3 20 MOORES ROAD following Table 1D. MALVERN, PENNSYLVANIA 19355 (610) 651-5847 5.3 For all above-deck insulations except foam plastics, www.certainteed.com the roof covering assembly, including such insulation, must have passed testing in accordance with UL 1256 or FM 4450. ESR-1388 | Most Widely Accepted and Trusted Page 4 of 14 TABLE 1A—EXTERNAL ROOF FIRE CLASSIFICATIONS1,7 INSULATED NONCOMBUSTIBLE DECKS6 MAX. 2,3,8 ROOF COVER VAPOR BARRIER OR INSULATION / SYSTEM NO. CLASS ROOF ANCHOR SHEET4 THICKNESS 4 4 Base Sheet Ply Sheet Membrane Surfacing SLOPE Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTS or Flintlastic GTS Type G2 or G2 CoolStar (HW), or (Optional) Karnak No. 97 Perlite, glass fiber or wood Glasbase Base Flintlastic GMS, A-1 A 1:12 Type G2 or G2 Glasbase None Fibrated Aluminum at fiber / max. 7.2-inch Sheet (MA) or Flintlastic GMS 1 (MA) or (HM) 1 /2 gal/sq. (HM) CoolStar (HM) or Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar (HM) Type G2 or G2 (Optional) Flintlastic STA or Karnak No. 97 3 Perlite, glass fiber or wood Glasbase Base A-2 A /4:12 Type G2 or G2 Glasbase None Flintlastic STA Fibrated Aluminum at fiber / max. 7.2-inch Sheet (MA) or 1 Base Sheet (MA) or (HM) Plus (HW) 1 /2 gal/sq. (HM) Type G2 or G2 (Optional) Flintlastic STA or Karnak No. 97 Perlite, glass fiber or wood Glasbase Base A-3 B 1:12 Type G2 or G2 Glasbase None Flintlastic STA Fibrated Aluminum at fiber / max. 7.2-inch Sheet (MA) or 1 Base Sheet (MA) or (HM) Plus (HW) 1 /2 gal/sq. (HM) Tropical 120AF, Karnak No. 97 AF, Flintlastic STA or Henry No. 520, Flintlastic STA Polyisocyanurate, perlite, (Optional) One Grundy AlMB AF at 1 Type G1 or G2 Plus, Flintlastic 1 A-4 A /2:12 None glass fiber or wood fiber / or more Type 1 /2 gal/sq. or Monsey (MA) or (HM) GTA, or Flintlastic minimum 1 inch thick G1 or G2 (HM) Fibered Asphalt GTA CoolStar Emulsion or Henry (HW) No. 107 Emulsion at 3 gal/sq. Type G2 or G2 Polyisocyanurate, perlite, (Optional) One Flintlastic GTA-FR 1 GlasbaseBase A-5 A 1 /2:12 None glass fiber or wood fiber / or more Type or Flintlastic GTA- None Sheet (MA) or any thickness G1 or G2 (HM) FR CoolStar (HW) (HM) Flintlastic FR-P, Flintlastic FR-P (Optional) CoolStar, Flintlastic Poly Flintlastic SMS Base Premium FR-P, Sheet or Flintlastic 1.5-inch min. to 4 in. max. Glasbase Base Flintlastic Ultra Premium FR-P ENRGY 3, ACFoam II or Sheet or Poly SMS Base CoolStar or FlintBoard ISO followed by A-65 A 1/ 3 Flexiglas Base Sheet applied Flintlastic FR Cap 2:12 None min. /4-inch Fesco Board or Sheet or with Karnak No. 30 or Flintlastic FR None Permalite or min. 1/ 2-inch Flintlastic Base 81 Modified Cap 30 CoolStar DensDeck or DensDeck 20 (MA) Bitumen applied with Prime Adhesive Brush Karnak No. 81 Grade or Modified Bitumen FlintBond Brush Adhesive Brush at 11/ Grade or 2 gal/sq. FlintBond Brush at 11/ 2 gal/sq. Flintlastic FR Cap 1 Min. 4 inch Flintlastic Base 30 T or Flintlastic A-7 A 1 /2:12 None None None Polyisocyanurate 20 T (HW) FR Cap 30 T CoolStar (HW) (Optional) Polyisocyanurate, Flintlastic Flintlastic GTA-FR A-8 A ¾:12 None perlite, glass fiber or wood None UltraGlass SA or Flintlastic GTA- None fiber / any thickness (SA) FR CoolStar (HW) Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar (Optional) Polyisocyanurate, Flintlastic Ultra (HM) or Flintlastic A-9 A ½:12 None perlite, glass fiber / any None None Glass SA (SA) FR Cap 30 T or thickness Flintlastic FR Cap 30 T CoolStar (HW) For SI: 1 inch = 25.4 mm, 1 gal/sq. = 0.41 l/m2. ESR-1388 | Most Widely Accepted and Trusted Page 5 of 28 TABLE 1B—EXTERNAL ROOF FIRE CLASSIFICATIONS1,7 NONINSULATED NONCOMBUSTIBLE DECKS6 MAX. ROOF COVER SYSTEM CLASS ROOF NO. SLOPE Base Sheet4 Ply Sheet4 Membrane Surfacing Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTS or Flintlastic GTS CoolStar (HW) or Type G2 or G2 Glasbase Base Sheet Karnak No. 97 Fibrated B-1 A 1:12 None Flintlastic GMS, Flintlastic GMS 1 (MA) or (HM) Aluminum at 1 /2 gal/sq. CoolStar or Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, (HM) 3 Type G2 or G2 Glasbase Base Sheet Flintlastic STA or Flintlastic STA Karnak No. 97 Fibrated B-2 A /4:12 None 1 (MA) or (HM) Plus (HW) Aluminum at 1 /2 gal/sq. Type G2 or G2 Glasbase Base Sheet Flintlastic STA or Flintlastic STA Karnak No. 97 Fibrated B-3 B 1:12 None 1 (MA) or (HM) Plus (HW) Aluminum at 1 /2 gal/sq. (Optional) 1 Type G2 or G2 Glasbase Base Sheet Flintlastic GTA-FR or Flintlastic B-4 A 1 /2:12 One or more Type G1 None (MA) or (HM) GTA-FR CoolStar (HW) or G2 (HM) B-5 A 1/ 2:12 Flintlastic SA NailBase (MA) None Flintlastic SA P-Cap-FR (SA) None Flintlastic SA NailBase (MA) or Flintlastic 1 Flintlastic SA PlyBase Flintlastic SA Cap FR, Flintlastic SA B-6 A /2:12 SA PlyBase (SA to primed DensDeck or None (SA) Cap FR CoolStar (SA) DensDeck DuraGuard only) Flintlastic FR-P fully-adhered with 1 Flintlastic Ultra Glass B-7 B /2:12 None FlintBond Brush Grade Adhesive at None SA (SA) 1 1 /2 gal/sq. 1 Flintlastic Ultra Glass B-8 B /2:12 None Flintlastic FR-P (HM) None SA (MA) 1 Flintlastic SA Mid Ply Flintlastic SA Cap FR or Flintlastic B-9 A /4:12 None None (SA) SA Cap FR CoolStar (SA) (Optional) Flintlastic Flintlastic GTA-FR or Flintlastic B-10 A ¾:12 Flintlastic APP Base T (MA) or (HW) None APP Base T (HW) GTA-FR CoolStar (HW) (Optional) Flintlastic Flintlastic GTA or Flintlastic GTA B-11 B ¼:12 Flintlastic APP Base T (MA) or (HW) None APP Base T (HW) CoolStar (HW) For SI: 1 inch = 25.4 mm, 1 gal/sq. = 0.41 l/m2. TABLE 1C—EXTERNAL ROOF FIRE CLASSIFICATIONS1,7 INSULATED COMBUSTIBLE DECKS6 MAX. 2,3,8 ROOF COVER SYSTEM VAPOR BARRIER INSULATION / CLASS ROOF 4 NO. SLOPE OR ANCHOR SHEET THICKNESS Base Sheet4 Ply Sheet4 Membrane Surfacing Flintlastic STA or Flintlastic STA Plus, Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic Type G2 or G2 Type G2 or G2 Perlite or fiberglass / GTS or Flintlastic Flood coat and Glasbase Base C-1 A 1:12 Glasbase Base Sheet min. 1-inch, max. None GTS CoolStar (HW) gravel at 400 Sheet (MA) or (LL) or (MA) 1.5-inch or Flintlastic GMS, pounds per square (HM) Flintlastic GMS CoolStar or Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar (HM) Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTS or Flintlastic (Optional) Type G2 or G2 Perlite, glass fiber or Type G2 or G2 GTS CoolStar (HW) Karnak No. 97 1 Type G2 or G2 Glasbase Base C-2 A /4:12 wood fiber / max. Glasbase Base or Flintlastic GMS, Fibrated Aluminum Glasbase Base Sheet Sheet (MA) or 1 7.2-inch Sheet (LL) or (MA) Flintlastic GMS at 1 /2 gal/sq. (LL) or (MA) (HM) CoolStar or Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar (HM) ESR-1388 | Most Widely Accepted and Trusted Page 6 of 28 TABLE 1C—EXTERNAL ROOF FIRE CLASSIFICATIONS1,7 INSULATED COMBUSTIBLE DECKS6 (Continued) MAX. 2,3,8 ROOF COVER SYSTEM VAPOR BARRIER INSULATION / CLASS ROOF 4 NO. SLOPE OR ANCHOR SHEET THICKNESS Base Sheet4 Ply Sheet4 Membrane Surfacing Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTS or Flintlastic (Optional) Type G2 or G2 GTS CoolStar (HW) Karnak No. 97 1 Type G2 or G2 Perlite / min. Glasbase Base C-3 A /4:12 None or Flintlastic GMS, Fibrated Aluminum Glasbase Base Sheet 1.5-inch Sheet (MA) or 1 Flintlastic GMS at 1 /2 gal/sq. (LL) or (MA) (HM) CoolStar or Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar (HM) Polyisocyanurate, Type G2 or G2 Flintlastic FR Cap 30 1 perlite, glass fiber or Glasbase Base C-4 A /2:12 None None or Flintlastic FR Cap None wood fiber / any Sheet (MA) or 30 CoolStar (HM) thickness (HM) (Optional) One or more Type One or more G1, Type G2 or Flexiglas Base Flexiglas Base Flintlastic FR Cap 30 Sheet or Flintlastic Sheet or Flintlastic or Flintlastic FR Cap Base 20 adhered Base 20 or 30 CoolStar adhered 1 Perlite, glass fiber / any C-5 A /2:12 None with Henry 553 Flintlastic Poly with Henry 553 MBA None thickness MBA Gold SMS Base Sheet Gold Modified Modified Bitumen adhered with Bitumen Adhesive at Adhesive at 11/ 1 2 Henry 553 MBA 1 /2 gal/sq. gal/sq. Gold Modified Bitumen Adhesive at 11/ 2 gal/sq. Flintlastic SA Cap-FR 1 DensDeck / min. Flintlastic SA C-6 A /2:12 None 1 None or Flintlastic SA Cap- None /4-inch NailBase (MA) FR CoolStar (SA) Polyisocyanurate, Flintlastic SA Cap-FR perlite, glass fiber or Flintlastic SA Flintlastic SA Mid C-7 C 2:12 None or Flintlastic SA Cap- None wood fiber / any NailBase (MA) Ply (SA) FR CoolStar (SA) thickness Flintlastic SA Polyisocyanurate, NailBase (MA) or perlite, glass fiber or Flintlastic SA Flintlastic SA Cap FR, 1 wood fiber / any Flintlastic SA C-8 A /2:12 None PlyBase (SA to Flintlastic SA Cap-FR None thickness PlyBase (SA) primed DensDeck CoolStar (SA) DensDeck / min. 1 or DensDeck /4-inch DuraGuard only) Perlite, glass fiber or Flintlastic SA Cap FR Flintlastic SA C-9 C Unlimited None wood fiber / any None or Flintlastic SA Cap- None NailBase (MA) thickness FR CoolStar (SA) (Optional) Polyisocyanurate, Flintlastic SA Mid Flintlastic SA Cap FR perlite, glass fiber or Flintlastic SA C-10 C 2:12 None Ply (SA) or or Flintlastic SA Cap- None wood fiber / any NailBase (MA) Flintlastic SA FR CoolStar (SA) thickness PlyBase (SA) Flintboard ISO / min. 1.5 inch Flintlastic FR Cap 30 1 (presecured) Flintlastic Base 20 T or Flintlastic FR C-11 A 1 /2:12 None None None DensDeck /min. T (HW) Cap 30 T CoolStar 1/ (HW) 4-inch adhered in hot asphalt For SI: 1 inch = 25.4 mm, 1 gal/sq. = 0.41 l/m2. ESR-1388 | Most Widely Accepted and Trusted Page 7 of 28 TABLE 1D—EXTERNAL ROOF FIRE CLASSIFICATIONS1,7 NONINSULATED COMBUSTIBLE DECKS6 MAX. ROOF COVER SYSTEM CLASS ROOF NO. SLOPE Base Sheet4 Ply Sheet4 Membrane Surfacing Flintlastic FR-P, Flintlastic 1 or more layers Yosemite FR-P CoolStar, Flintlastic Firecade 2000 or Premium Long D-1 A 1/ Life Aluminum Roof Coating at 2:12 Venting Base Sheet (MA) or None Premium FR-P or Flintlastic 11/ (HM) Premium FR-P CoolStar 2 gal/sq. (HM) Flintlastic STA, Flintlastic STA Plus, Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTS or Flintlastic 1 Type G2 or G2 Glasbase Base Type G2 or G2 Glasbase Base GTS CoolStar (HW) or Karnak No. 97 Fibrated D-2 A /4:12 1 Sheet (LL)or (MA) Sheet (MA)or (HM) Flintlastic GMS, Flintlastic Aluminum at 1 /2 gal/sq. GMS CoolStar or Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar (HM) Flintlastic FR Cap 30 or 1 Type G2 or G2 Glasbase Base D-3 A /2:12 None Flintlastic FR Cap 30 None Sheet (MA) or (HM) CoolStar (HM) (Optional) One or more Flexiglas Base One or more Type G1, Type G2 Flintlastic FR Cap 30 or Sheet or Flintlastic Base 20 or Flexiglas Base Sheet or Flintlastic FR Cap 30 1 adhered with Henry 553 MBA Flintlastic Base 20 or Flintlastic CoolStar adhered with Henry D-4 A /2:12 None Gold Modified Bitumen Poly SMS Base Sheet adhered 553 MBA Gold Modified 1 with Henry 553 MBA Gold Bitumen Adhesive at 11/ Adhesive at 1 /2 gallons per 2 square Modified Bitumen Adhesive at gal/sq. 11/ 2 gal/sq. Flintlastic GTA, Flintlastic GTA CoolStar (HW) or (Optional) Flintlastic GMS, Flintlastic 1 Type G2 or G2 Glasbase Base D-5 B /2:12 One or more Type G2 or GMS CoolStar or Flintlastic None Sheet (MA) G2 Glasbase Base Sheet (HM) Premium GMS, Flintlastic Premium GMS CoolStar (HM) Flintlastic SA Cap-FR or 1 Type G2 Glasbase Base Sheet D-6 A /2:12 Flintlastic SA NailBase (MA) Flintlastic SA Cap-FR None (MA) CoolStar (SA) Flintlastic SA Cap-FR or D-7 C 2:12 Flintlastic SA NailBase (MA) Flintlastic SA Mid Ply (SA) Flintlastic SA Cap-FR None CoolStar (SA) Flintlastic SA Cap-FR or D-8 C Unlimited Flintlastic SA NailBase (MA) None Flintlastic SA Cap-FR None CoolStar (SA) (Optional) Flintlastic SA Cap-FR or D-9 C 2:12 Flintlastic SA NailBase (MA) Flintlastic SA Mid Ply (SA) or Flintlastic SA Cap-FR None Flintlastic SA PlyBase (SA) CoolStar (SA) Flintlastic SA NailBase or Flexiglas Base Sheet or Flintlastic GTA-FR or D-10 A 2:12 Flintlastic Base 20 or Yosemite Flintlastic Ultra Glass SA (SA) Flintlastic GTA-FR CoolStar None Venting Base Sheet or (HW) Glasbase Base Sheet (MA) Glasbase Base Sheet Base Flintlastic FR Cap 30, Sheet or Flintlastic SA NailBase Flintlastic FR Cap 30 D-11 A ½:12 or Flexiglas Base Sheet or Flintlastic Ultra Glass SA (SA) CoolStar (HM) or Flintlastic None Flintlastic Base 20 or Yosemite FR Cap 30 T, Flintlastic FR Venting Base Sheet (MA) Cap 30 T CoolStar (HW) For SI: 1 inch = 25.4 mm, 1 gal/sq. = 0.41 l/m2. Footnotes for Table 1A thru Table 1D, as applicable: 1Unless otherwise specified (see Footnote 5), vapor barriers, anchor sheets, insulation, adhesives, base sheets, ply sheets, membranes, and surface coatings must be UL classified for roofing systems. 2Foam plastic insulation thickness is limited to the lesser of the maximum thickness specified in this table or the maximum thickness stated on the label, that limits the flame spread index to not more than 75 when tested in accordance with ASTM E84. 3Foam plastic insulation may be installed over a steel deck without a thermal barrier when installed in accordance with an ICC-ES evaluation report recognizing direct application of a specific foam plastic insulation. Reference: 4Type G1 and Type G2 relate to any UL classified fiberglass reinforced ply or base sheet respectively, complying with UL 55A. 5Insulation, adhesives, base sheets, ply sheets and membranes in system A-6 must be FM – Approved for roofing systems. 6Combustible wood decks must be minimum 15/ 7 3 32-inch-thick (11.9 mm) plywood, /16-inch-thick (11.1 mm) nonveneer APA rated oriented strand board or /4-inch-thick (19 mm) sheathing boards. Steel decks must be minimum No. 22 gage galvanized steel [0.030 inch (0.76 mm)]. Concrete decks must have a minimum compressive strength (fc) of 2500 psi. 7Abbreviations: (MA) Mechanically Fastened (HM) Hot Mopped with hot roofing asphalt conforming to ASTM D312, Type III or IV. (HW) Heat Welded (LL) Loose Laid (SA) Self-Adhered 8Polyisocyanurate insulation must comply with ASTM C1289, Type I or Type II. Perlite insulation must comply with ASTM C728. Wood fiberboard insulation must comply with ASTM C208. ESR-1388 | Most Widely Accepted and Trusted Page 8 of 28 TABLE 2A—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT MECHANICALLY ATTACHED BASE INSULATION, BONDED COVERBOARD INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE SYSTEM UPLIFT SUBSTRATE Attachment NO. Type Attach2 Type Base Ply Cap CAPACITY (psf) Method 4 1.5-inch min. to 4-inch max. Hot mopped Min. 22 ga. steel One to three plies applied FlintBoard ISO, 1 fastener 3 Mopped with with hot A-1 or min. 2,500 psi 2 Min. /4-inch FescoBoard in hot asphalt or heat 52.5 ACFoam-II, per 1.33 ft hot asphalt asphalt or concrete welded ENRGY 3, or heat welded Multi-Max FA-3 1.5-inch min. to 4-inch max. Hot mopped Min. 22 ga. steel 1 One to three plies applied FlintBoard ISO, 1 fastener Min. /2-inch HD Fiber Board Mopped with with hot A-2 or min. 2,500 psi 2 in hot asphalt or heat 67.5 ACFoam-II, per 1.33 ft Roof Insulation hot asphalt asphalt or concrete welded ENRGY 3, or heat welded Multi-Max FA-3 Min. 1/ 2-inch Armor Board HD, BP High Strength, ERS Redi-Deck, GAFTEMP HD, 2-inch min. to Hot mopped Roof Insulation Board, One to three plies applied 4-inch max. 1 fastener Mopped with with hot A-3 Min. 22 ga. steel 2 Structodek HD Fiberboard or in hot asphalt or heat 45.0 FlintBoard ISO or per 3.2 ft hot asphalt asphalt or FiberBase HD1/HD6 or min. welded ACFoam-II 3 heat welded /4-inch ConPerl, Fesco Board or EnergyGuard Perlite Flintlastic Adhered with GTA or Min. 1.5-inch Millennium Min. 22 ga. steel 1 fastener Min. 1.5-inch Firestone ISO Flintlastic Ultra Glass SA, Flintlastic A-4 Firestone ISO 95+ 2 One Step 37.5 Min. 33 ksi Steel per 1.33 ft 95+ GL self-adhered GTA GL Foamable 5 CoolStar, Adhesive heat welded Adhered with Millennium One Step Foamable Adhesive, Base: Black Diamond Base Flintlastic Min. 1.5-inch Millennium Sheet or Flintlastic Ultra GTA-FR or ACFoam-II, H- Min. 1.5-inch ACFoam-II, H- 1 fastener PG-1 Low Glass SA, self-adhered Flintlstic A-5 Min. 22 ga. steel Shield, FlintBoard 2 Shield, FlintBoard ISO or 45.0 per 1.45 ft Viscosity GTA-FR ISO or FlintBoardH FlintBoardH ISO Insulation Ply: Flintlastic APP Base T, CoolStar, ISO Adhesive, heat welded heat welded Insta-Stik, OlyBond 500 or OlyBond 500 Green5 Adhered with Millennium Flintlastic One Step GTA, Foamalbe Flintlastic Adhesive, Min. 1.5-inch GTA Millennium ACFoam-II, H- CoolStar, 1 fastener Min. ¼-inch SECUROCK PG-1 Low Flintlastic STA or Flintlastic A-6 Min. 22 ga. steel Shield, FlintBoard 2 Flintlastic 75.0 per 1.45 ft Gypsum-Fiber Roof Board Viscosity APP Base T, heat welded ISO or FlintBoardH GTA-FR or Insulation ISO Flintlastic Adhesive, GTA-FR Insta-Stik, CoolStar, OlyBond 500 heat welded or OlyBond 500 Green5 Adhered with Millennium One Step Foamable Adhesive, Base: Black Diamond Base Flintlastic Min. 1.5-inch Millennium Sheet or Flintlastic Ultra GTA-FR or ACFoam-II, H- Min. 1.5-inch ACFoam-II, H- Min. 15/32-inch 1 fastener PG-1 Low Glass SA, self-adhered Flintlastic A-7 Shield, FlintBoard 2 Shield, FlintBoard ISO or 67.5 plywood per 1.33 ft Viscosity GTA-FR ISO or FlintBoardH FlintBoardH ISO Insulation Ply: Flintlastic APP Base T, CoolStar, ISO Adhesive, heat welded heat welded Insta-Stik, OlyBond 500 or OlyBond 500 Green5 ESR-1388 | Most Widely Accepted and Trusted Page 9 of 28 TABLE 2A—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT MECHANICALLY ATTACHED BASE INSULATION, BONDED COVERBOARD (Continued) INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE SYSTEM UPLIFT SUBSTRATE Attachment NO. Type Attach2 Type Base Ply Cap CAPACITY (psf) Method 4 Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Thermal Barrier: Premium FR- Min. ¼-inch P, Flintlastic DensDeck, Base: Flintlastic Poly SMS Premium FR- Min. 1.5-inch ACFoam-III, H- Adhered with SECUROCK Base, Flintlastic Ultra Poly P CoolStar, Shield CG, FlintBoard ISO OlyBond 500 Gypsum-Fiber SMS or Flintlastic Base 20, Flintlastic FR Cold or FlintBoardH ISO Cold Adhesive, Min. 22 ga. steel Roof Board or adhered with Karnak No. 81 Cap 30 or 1 fastener applied in min. A-8 or min. 2,500 psi GlasRoc Roof 2 Modified Bitumen Adhesive Flintlastic FR 45.0 per 2 ft OR ¾-inch wide concrete Board, loose laid Brush Grade or FlintBond Cap 30 beads spaced followed by min. Brush at a rate of 1 gal/sq. CoolStar, Min. ¼-inch SECUROCK max. 12-inch 2.0-inch ACFoam- adhered with Gypsum-Fiber Roof Board o.c. II, H-Shield, Ply: None Karnak No. FlintBoard ISO or 81 Modified FlintBoardH ISO Bitumen Adhesive Brush Grade or FlintBond Brush at a rate of 1 gal/sq. Flintlastic FR Adhered with Cap 30, Millennium Flintlastic FR One Step Cap 30 Foamable CoolStar, Adhesive, Flintlastic Poly SMS Base, Min. 1.5-inch Flintlastic Millennium Flintlastic Ultra Poly SMS ACFoam-II, H- FR-P, 1 fastener Min. ¼-inch SECUROCK PG-1 Low Base or Flintlastic Base 20 A-9 Min. 22 ga. steel Shield, FlintBoard 2 Flintlastic 75.0 per 1.6 ft Gypsum-Fiber Roof Board Viscosity adhered with FlintBond ISO or FlintBoardH FR-P Insulation Brush, at a rate of 1.0-1.5 ISO CoolStar, Adhesive, gal/sq. adhered with Insta-Stik, FlintBond OlyBond 500 Brush, at a or Olybond 5 rate of 1.0- 500 Green 1.5 gal/sq. Adhered with Millennium Flintlastic One Step GTA, Foamalbe Flintlastic Adhesive, Min. 1.5-inch GTA Millennium ACFoam-II, H- CoolStar, Min. 15/32-inch 1 fastener Min. ¼-inch SECUROCK PG-1 Low Flintlastic STA or Flintlastic A-10 Shield, FlintBoard 2 Flintlastic 90.0 plywood per 1.33 ft Gypsum-Fiber Roof Board Viscosity APP Base T, heat welded ISO or FlintBoardH GTA-FR or Insulation ISO Flintlastic Adhesive, GTA-FR Insta-Stik, CoolStar, OlyBond 500 heat welded or OlyBond 500 Green5 ESR-1388 | Most Widely Accepted and Trusted Page 10 of 28 TABLE 2B—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT ALL INSULATION LAYERS MECHANICALLY ATTACHED THROUGH TOP INSULATION LAYER OR COVERBOARD INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE SYSTEM UPLIFT SUBSTRATE Attachment2 NO. Type Attach2 Type Method Base Ply Cap CAPACITY (psf) 4 Min. 22 ga. Min. 1/ steel, min. Min. 1.5-inch, 4-inch (Optional) 2,500 psi min. 2.0 pcf DensDeck primed 1 fastener Flintlastic SA Mid Flintlastic SA B-1 Loose laid 2 Self-Adhered 45.0 concrete or polyiso- with FlintPrime SA at per 1.33 ft Ply, self-adhered Mid Ply, self- min. 19/ cyanurate 0.3 gal/sq. adhered 32-inch plywood 1.5-inch min. to Black Diamond (Optional) Min. 22 ga. 4-inch max. 1 fastener per 2 Base Sheet or One or two Hot mopped steel or min. FlintBoard ISO, 1.33 ft B-2 None N/A Flintlastic Ultra plies applied in with hot 52.5 2,500 psi ACFoam-II, through top Glass SA, self- hot asphalt or asphalt concrete ENRGY 3 or layer adhered heat welded Multi-Max FA-3 1.5-inch min. to Black Diamond (Optional) Min. 22 ga. 4-inch max. 1 fastener per 2 Base Sheet or One or two steel or min. FlintBoard ISO, 1.33 ft B-3 None N/A Flintlastic Ultra plies applied in Heat welded 82.5 2,500 psi ACFoam-II, through top Glass SA, self- hot asphalt or concrete ENRGY 3 or layer adhered heat welded Multi-Max FA-3 Max. 3-inch- thick OC 1 Min. /2-inch Armor FOAMULAR Board HD, BP High 350 or max. Strength, ERS Redi- 4-inch-thick Hy- Deck, GAFTEMP Therm AP, HD, Roof Insulation FlintBoard ISO, Board, Structodek Min. 22 ga. ACFoam-II, One to three plies in hot asphalt Hot mopped HD Fiberboard or steel or min. PSI 25, H- 1 fastener full-mop or spot mopped in hot with hot B-4 Loose laid FiberBase HD1/HD6 2 45.0 2,500 psi Shield, 3 per 2 ft asphalt in 24-inch diameter spots asphalt or heat or min. /4-inch concrete FlintBoardH spaced 30-inch o.c. or heat welded welded ConPerl, Fesco ISO, H-Shield Board or P, H-Shield WF, EnergyGuard Perlite FlintBoardH ISO 1 or min. /4-inch WF, H-Shield DensDeck or NB or DensDeck Prime FlintBoardH ISO NB. 1.5-inch min. to 4-inch max. Hy- Yosemite Venting Min. 22 ga. Therm AP, Base Sheet spot Hot mopped steel or min. ENRGY 3 or Min. 1-inch Fesco 1 fastener mopped in hot with hot B-5 Loose laid 2 None 45.0 2,500 psi PSI-25 or min. Board per 1.6 ft asphalt in 24-inch asphalt or heat concrete 2-inch diameter spots welded FlintBoard ISO spaced 30-inch o.c or ACFoam-II Flintlastic FR- P, Flintlastic FR-P CoolStar, (Optional) Flintlastic Thermal Barrier: Premium FR- Min. 1.5-inch Min. ¼-inch P, Flintlastic ACFoam-III, H- Flintlastic Poly DensDeck, Premium FR-P Shield CG, SMS Base, SECUROCK CoolStar, FlintBoard ISO Cold Flintlastic Ultra Poly Gypsum-Fiber Flintlastic FR or FlintlasticH ISO SMS or Flintlastic Min. 22 ga. Roof Board or Cap 30 or Cold Base 20, adhered Steel or min. GlasRoc Roof 2 Flintlastic FR B-6 Loose laid 1 fastener per 2 ft with Karnak No. 81 None 45.0 2,500 psi Board, loose Cap 30 OR Modified Bitumen concrete laid followed by CoolStar, Adhesive Brush min. 1.5-inch adhered with Min. ¼-inch Grade or FlintBond ACFoam-II, H- Karnak No. 81 SECUROCK Brush at a rate of 1 Shield, Modified Gypsum-Fiber Roof gal/sq. FlintBoard ISO Bitumen Board or FlintBoardH Adhesive ISO Brush Grade or FlintBond Brush at a rate of 1 gal/sq. ESR-1388 | Most Widely Accepted and Trusted Page 11 of 28 TABLE 2B—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT ALL INSULATION LAYERS MECHANICALLY ATTACHED THROUGH TOP INSULATION LAYER OR COVERBOARD (Continued) INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE SYSTEM UPLIFT SUBSTRATE Attachment2 NO. Type Attach2 Type Method Base Ply Cap CAPACITY (psf) 4 Flintlastic FR- P, Flintlastic Thermal FR-P CoolStar, Barrier: Min. ¼- Flintlastic inch DensDeck, GMS, SECUROCK Flintlastic GMS Gypsum-Fiber CoolStar, Roof Board or Min. 22 ga. Flintlastic GlasRoc Roof Base: Flintlastic steel or min. 1 fastener per Premium FR- B-7 Board, loose 2 None N/A Ultra Glass SA, None 75.0 2,500 psi 1.45 ft P, Flintlastic laid followed by self-adhered concrete Premium FR-P min. 1.5-inch CoolStar, ACFoam-II, H- Flintlastic Shield, Premium GMS FlintBoard ISO or Flintlastic or FlintBoardH Premium GMS ISO CoolStar, hot asphalt Flintlastic GTA, Min. 1.5-inch Flintlastic GTA (Optional) ACFoam-II, H- Min. ¼-inch Flintlastic STA or CoolStar, Flintlastic STA Min. 22 ga. Shield, SECUROCK 2 Flintlastic APP Flintlastic GTA- B-8 Loose laid 1 fastener per 1.45 ft or Flintlastic 60.0 steel FlintBoard ISO Gypsum-Fiber Roof Base T, heat FR or APP Base T, or FlintBoardH Board welded Flintlastic GTA- heat welded ISO FR CoolStar, heat welded Flintlastic GTA, Min. 1.5-inch Flintlastic GTA (Optional) ACFoam-II, H- Min. ¼-inch Flintlastic STA or CoolStar, Flintlastic STA Min. 15/32-inch Shield, SECUROCK 2 Flintlastic APP Flintlastic GTA- B-9 Loose laid 1 fastener per 1.33 ft or Flintlastic 67.5 plywood FlintBoard ISO Gypsum-Fiber Roof Base T, heat FR or APP Base T, or FlintBoardH Board welded Flintlastic GTA- heat welded ISO FR CoolStar, heat welded Min. 1.5-inch Min. 1.5-inch Black Diamond Flintlastic GTA- ACFoam-II, H- ACFoam-II, H- Base Sheet or Flintlastic APP FR or Min. 22 ga. Shield, 2 B-10 Loose laid Shield, FlintBoard 1 fastener per 1.45 ft Flintlastic Ultra Base T, heat Flintlastic GTA- 75.0 steel FlintBoard ISO ISO or FlintBoardH Glass SA, self- welded FR CoolStar, or FlintBoardH ISO adhered heat welded ISO Min. 1.5-inch Min. 1.5-inch Black Diamond Flintlastic GTA- ACFoam-II, H- ACFoam-II, H- Base Sheet or Flintlastic APP FR or Min. 15/32-inch Shield, B-11 Loose laid Shield, FlintBoard 1 fastener per 1.33 ft2 Flintlastic Ultra Base T, heat Flintlastic GTA- 75.0 plywood FlintBoard ISO ISO or FlintBoardH Glass SA, self- welded FR CoolStar, or FlintBoardH ISO adhered heat welded ISO Flintlastic GTA, Min. 1.5-inch Flintlastic GTA (Optional) ACFoam-II, H- Min. ½-inch Flintlastic STA or CoolStar, Flintlastic STA Min. 22 ga. Shield, SECUROCK 2 Flintlastic APP Flintlastic GTA- B-12 Loose laid 1 fastener per 1 ft or Flintlastic 120.0 steel FlintBoard ISO Gypsum-Fiber Roof Base T, heat FR or APP Base T, or FlintBoardH Board welded Flintlastic GTA- heat welded ISO FR CoolStar, heat welded 1.5-inch min. to 4-inch max. Hy- 1 Yosemite Venting Min. /2-inch Min. 22 ga. Therm AP, Base Sheet spot Hot mopped Structodek, steel or min. ENRGY 3 or 1 fastener mopped in hot with hot B-13 Loose laid FiberBase HD1/HD6 2 None 45.0 2,500 psi PSI-25 or min. per 2 ft asphalt in 24-inch asphalt or heat or GP HD Roof concrete 2-inch diameter spots welded Fiberboard FlintBoard ISO spaced 30-inch o.c or ACFoam II (Optional) One or more layers 19 min. 1.5” Min. /32-inch Flintlastic SA Mid (Optional) ACFoam-II, Min. 1.5" ACFoam-II, plywood at max Ply or Flintlastic SA Flintlastic SA ENRGY 3, ENRGY 3, HShield, 24-inch spans 1 fastener PlyBase, self- Mid Ply or B-14 H-Shield, Loose laid Mult-Max 2 Self-Adhered 60.0 attach 6-inch per 1.45 ft adhered (Substrate Flintlastic SA FlintBoardH FA-3, FlintBoard ISO o.c. using 8d Primed with Flint- PlyBase, self- ISO, or FlintBoardH ISO ring shank nails Prime SA) adhered Mult-Max FA-3 or FlintBoard ISO ESR-1388 | Most Widely Accepted and Trusted Page 12 of 28 TABLE 2B—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT ALL INSULATION LAYERS MECHANICALLY ATTACHED THROUGH TOP INSULATION LAYER OR COVERBOARD (Continued) INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE SYSTEM UPLIFT SUBSTRATE Attachment2 NO. Type Attach2 Type Method Base Ply Cap CAPACITY (psf) 4 Min. 1.5-inch Owens-Corning FOAMULAR, Hy-Therm AP, Hy-Therm(a) AP, FlintBoard ISO, ACFoam- Min. 22 ga. II, ENRGY 3, 1 Min. /4-inch Flintlastic FR Cap 30 T or steel or min. PSI-25, H- 1 fastener Flintlastic Base 20 B-15 Loose laid DensDeck or None Flintlastic FR Cap 30 T 45.0 2,500 psi Shield, per 2 ft² T, heat welded DensDeck Prime CoolStar, heat welded concrete FlintBoardH ISO, H-Shield- P, H-Shield-WF, FlintBoardH ISO WF, H-Shield- NB or FlintBoardH ISO NB Tectum 1 Min 5/ Plank 8-inch Flintlastic FR Cap 30 T or (install per DensDeck or 1 fastener Flintlastic Base 20 B-16 None N/A None Flintlastic FR Cap 30 T 45.0 ESR-1112) or DensDeck per 4 ft² T, heat welded CoolStar, heat welded existing Prime substrate Min. 1/ 4-inch Flintlastic FR Cap 30 T or Existing DensDeck or 1 fastener Flintlastic Base 20 B-17 None N/A None Flintlastic FR Cap 30 T 45.0 substrate DensDeck per 2 ft² T, heat welded CoolStar, heat welded Prime 1 fastener per 1.33 ft2 and Glasbase Base Flintlastic FR-P or adhered with Sheet, adhered Min. 22 ga. Flintlastic FR-P CoolStar Min. 1.5-inch Min. ¼-inch Millennium with Millennium B-18 steel Min. 33 Loose laid None adhered with Millennium 30.0 FlintBoard ISO DensDeck Prime Hurricane Hurricane Force ksi Steel Hurricane Force Force Membrane Membrane Adhesive Membrane Adhesive Adhesive5 (Optional) Flintglas Ply Sheet Type IV, Flintglas Premium Min. 1.5-inch Ply Sheet Type ACFoam-II, Yosemite Venting VI, Flintlastic (Optional) One ENRGY 3, Multi- Base, hot-asphalt Min. 22 ga., 1 fastener Base 20, Hot mopped B-19 or more layers, Loose laid Max FA-3, H- 2 in 9-inch diameter 52.5 steel per 1.45 ft Flintlastic Poly with hot asphalt any combination Shield, FlintBoard spots in 24-inch SMS Base or ISO or grid pattern Flintlastic Ultra FlintBoardH ISO Poly SMS Base, hot-asphalt at a rate of 20-40 lbs/sq. 1 fastener per 1.33 ft2 Min. 1.5-inch ACFoam-II, Primed Flintlastic SA Cap Min. ¼- Flintlastic SA (Optional) Min. 22 ga. ENRGY 3, coverboard or Flintlastic SA B-20 inch Mid Ply, self- Flintlastic SA Mid 45.0 steel Multi-Max FA-3 surface with Cap CoolStar DensDeck adhered Ply, self-adhered or FlintBoard FlintPrime SA self-adhered ISO, loose-laid primer, applied at a rate of 0.3 gal/sq. Min. 1.5-inch Flintlastic SA ACFoam-II, Cap, Flintlastic ENRGY 3, H- Flintlastic SA (Optional) SA Cap CoolStar, Shield, Multi- PlyBase or Flintlastic SA Min. 19/32-inch 1 fastener Flintlastic SA Cap B-21 Max FA-3, None 2 Flintlastic SA PlyBase or 45.0 plywood per 2 ft FR or Flintlastic FlintBoard ISO Mid Ply, self- Flintlastic SA Mid SA Cap FR or FlintBoardH adhered Ply, self-adhered CoolStar, self- ISO primed with adhered FlintPrime SA ESR-1388 | Most Widely Accepted and Trusted Page 13 of 28 TABLE 2C—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT MECHANICALLY ATTACHED BASE SHEET OVER INSULATION INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE SYSTEM UPLIFT SUBSTRATE Attachment NO. Type Attach Type Method Base2 Ply Cap CAPACITY (psf) 4 Yosemite Venting Base Sheet, (Optional) FM Flexiglas Base Sheet Min. 22 ga. Approved min. or Flintlastic Base 20 (Optional) Min. 1.5-inch, 3 Hot mopped with steel or min. /4-inch perlite min. attached 6-inch o.c. Hot mopped with C-1 min. 2.0 pcf Loose laid 1 Loose laid hot asphalt or 67.5 2,500 psi /2-inch wood in a 4-inch lap and 6- hot asphalt or polyisocyanurate heat welded concrete fiberboard or min. inch o.c. in two, heat welded 1/ 4-inch DensDeck equally spaced, staggered center rows Flintlastic Poly SMS Base Sheet or (Optional) FM Flintlastic Ultra Poly Min. 22 ga. Approved Min. SMS Base Sheet (Optional) Min. 1.5-inch, 3 Hot mopped with steel or min. /4-inch perlite min. attached 12-inch Hot mopped with C-2 min. 2.0 pcf Loose laid 1 Loose laid hot asphalt or 120 2,500 psi /2-inch wood o.c. in a 4-inch lap hot asphalt or polyisocyanurate heat welded concrete fiberboard or min. and 12-inch o.c. in heat welded 1/ two, equally spaced, 4-inch DensDeck staggered center rows Flintlastic Ultra Poly SMS Base Sheet (Optional) FM attached 12-inch Min. 22 ga. Approved min. Min. 1.5-inch, 3 o.c. in the 4-inch steel or min. /4-inch perlite min. C-3 min. 2.0 pcf Loose laid 1 Loose laid heat welded lap with None Heat welded 60 2,500 psi /2-inch wood polyisocyanurate Tru-Fast #15 EHD concrete fiberboard or min. 1 and Tru-Fast 2.4” /4-inch DensDeck Barbed Metal Seam Plates Flintlastic SA Min. 22 ga. (Optional) FM NailBase attached Steel, min. Approved min. (Optional) Min. 1.5-inch, 3 12-inch o.c. in a 4- 2,500 psi /4-inch perlite min. Flintlastic SA C-4 min. 2.0 pcf Loose laid 1 Loose laid inch lap and 12-inch Self-Adhered 60 concrete or /2-inch wood Mid Ply, self- 19 polyisocyanurate o.c. in two, equally min. /32-inch fiberboard or min. adhered 1 spaced, staggered plywood /4-inch DensDeck center rows Min. 1/ 2-inch Armor Board HD, BP High Max. 3-inch-thick Strength, ERS OC FOAMULAR Redi-Deck, CertainTeed base 350 or max. 4-inch- GAFTEMP HD, sheet (except thick Hy-Therm AP, Roof Insulation Yosemite Venting FlintBoard ISO, Min. 22 ga. Board, Structodek Base Sheet) (Optional) ACFoam-II, PSI 25, Hot mopped with steel or min. HD Fiberboard or 3 attached 12-inch Hot mopped with C-5 H-Shield, Loose laid Presecured hot asphalt or 30.0 2,500 psi FiberBase o.c. in a 4-inch lap hot asphalt or FlintBoardH ISO, H- heat welded concrete HD1/HD6 or min. and 36-inch o.c. in heat welded Shield P, H-Shield 3 /4-inch ConPerl, two, equally spaced, WF, FlintBoardH Fesco Board or staggered center ISO WF, H-Shield EnergyGuard rows NB or FlintBoardH Perlite or min. ISO NB. 1 /4-inch DensDeck or DensDeck Prime Min. 1/ 2-inch Armor Board HD, BP High Max. 3-inch-thick Strength, ERS OC FOAMULAR Redi-Deck, CertainTeed base 350 or max. 4-inch- GAFTEMP HD, sheet (except thick Hy-Therm AP, Roof Insulation Yosemite Venting FlintBoard ISO, Min. 22 ga. Board, Structodek Base Sheet) (Optional) ACFoam-II, PSI 25, Hot mopped with steel or min. HD Fiberboard or 3 attached 12-inch Hot mopped with C-6 H-Shield, Loose laid Presecured hot asphalt or 45.0 2,500 psi FiberBase o.c. in a 4-inch lap hot asphalt or FlintBoardH ISO, H- heat welded concrete HD1/HD6 or min. and 24-inch o.c. in heat welded Shield P, H-Shield 3 /4-inch ConPerl, two, equally spaced, WF, FlintBoardH Fesco Board or staggered center ISO WF, H-Shield EnergyGuard rows NB or FlintBoardH Perlite or min. ISO NB. 1 /4-inch DensDeck or DensDeck Prime ESR-1388 | Most Widely Accepted and Trusted Page 14 of 28 TABLE 2C—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT MECHANICALLY ATTACHED BASE SHEET OVER INSULATION (Continued) INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE SYSTEM UPLIFT SUBSTRATE Attachment NO. Type Attach Type Method Base2 Ply Cap CAPACITY (psf) 4 Min. 1/ 2-inch Armor Flintlastic Poly SMS Max. 3-inch-thick OC Board HD, BP High Base Sheet or FOAMULAR 350 or Strength, ERS Redi- Flintlastic Ultra Poly max. 4-inch-thick Hy- Deck, GAFTEMP HD, SMS Base Sheet Therm AP, Roof Insulation Board, attached 12-inch Min. 22 ga. FlintBoard ISO, Structodek HD (Optional) o.c. in a 4-inch lap Hot mopped with steel or min. ACFoam-II, PSI 25, Fiberboard or 3 Hot mopped with C-7 Loose laid Presecured and 36-inch o.c. in hot asphalt or 45.0 2,500 psi H-Shield, FlintBoardH FiberBase HD1/HD6 hot asphalt or 3 two, equally spaced, heat welded concrete ISO, H-Shield P, H- or min. /4-inch heat welded staggered center Shield WF, ConPerl, Fesco Board rows or 18-inch o.c. FlintBoardH ISO WF, or EnergyGuard in a 4-inch lap and H-Shield NB or Perlite or min. 1 18-inch o.c. in one FlintBoardH ISO NB. /4-inch DensDeck or staggered center row DensDeck Prime Min. 1/ 2-inch Armor Max. 3-inch-thick OC Board HD, BP High Flintlastic Poly SMS FOAMULAR 350 or Strength, ERS Redi- Base Sheet or max. 4-inch-thick Hy- Deck, GAFTEMP HD, Flintlastic Ultra Poly Therm AP, Roof Insulation Board, SMS Base Sheet Min. 22 ga. FlintBoard ISO, Structodek HD attached with SFS (Optional) Hot mopped with steel or min. ACFoam-II, PSI 25, Fiberboard or 3 Intec 2 in. round Hot mopped with C-8 Loose laid Presecured hot asphalt or 45.0 2,500 psi H-Shield, FlintBoardH FiberBase HD1/HD6 metal plates and #12 hot asphalt or 3 heat welded concrete ISO, H-Shield P, H- or min. /4-inch or #14 fasteners heat welded Shield WF, ConPerl, Fesco Board spaced 12-inch o.c. FlintBoardH ISO WF, or EnergyGuard in a 4-inch wide, H-Shield NB or Perlite or min. heat-welded side 1/ FlintBoardH ISO NB. 4-inch DensDeck or lap. DensDeck Prime Min. 1/ 2-inch to max 1- inch Armor Board HD, BP High Strength, Flintlastic Poly SMS ERS Redi-Deck, Base Sheet or GAFTEMP HD, Roof Flintlastic Ultra Poly Insulation Board, SMS Base Sheet (Recover) Structodek HD attached with SFS (Optional) Min. 22 ga. Hot mopped with Fiberboard or 3 Intec 2 in. round Hot mopped with C-9 steel or min. None N/A Presecured hot asphalt or 45.0 3 FiberBase HD1/HD6 metal plates and #12 hot asphalt or /4-inch 3 heat welded or min. /4-inch to max. or #14 fasteners heat welded plywood 1-inch ConPerl, Fesco spaced 12-inch o.c. Board or EnergyGuard in a 4-inch wide, Perlite or min. heat-welded side 1/ 4-inch to max. lap. 1-inch DensDeck or DensDeck Prime Flintlastic FR-P, Flintlastic FR-P (Optional) CoolStar, Flintlastic Poly Flintlastic GlasbaseBase SMS Base Premium FR-P, Sheet, Flexiglas or Sheet or Flintlastic Flintlastic Base 20 3 Flintlastic Ultra Premium FR-P Min. /4-inch Fesco attached 6-inch o.c. Min. 22 ga. 1.5-inch min. to Poly SMS Base CoolStar, Board or EnergyGuard in a 4-inch lap and steel or min. 4-inch max. 3 Sheet applied in Flintlastic FR Cap C-10 Loose laid Perlite or min. Presecured 12-inch o.c. in two, 45.0 2,500 psi FlintBoard ISO or 1 Karnak No. 81 30 or Flintlastic /2-inch DensDeck or equally spaced, concrete ACFoam-II Modified FR Cap 30 DensDeck Prime staggered center Bitumen CoolStar, applied rows (excludes ITW Adhesive Brush in Karnak No. 81 Buildex fasteners & Grade or Modified Btiumen plates) FlintBond Brush Adhesive Brush at 1.5 gal/square Grade or FlintBond Brush at 1.5 gal/square ESR-1388 | Most Widely Accepted and Trusted Page 15 of 28 TABLE 2C—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT MECHANICALLY ATTACHED BASE SHEET OVER INSULATION (Continued) INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE SYSTEM UPLIFT SUBSTRATE Attachment NO. Type Attach Type Method Base2 Ply Cap CAPACITY (psf) 4 19 One or more layers Flintlastic SA Min. /32-inch min. 1.5-inch NailBase attached (Optional) plywood at ACFoam-II, 1 8-inches o.c. in a 3- Flintlastic SA max 24-inch Min. /4-inch ENRGY 3, HShield, 3 inch lap and 8- Mid Ply or C-11 spans attached Loose laid DensDeck or Presecured Self-Adhered 82.5 Mult-Max inches o.c. in two, Flintlastic SA 6-inches o.c. DensDeck Prime FA-3, FlintBoard equally spaced, PlyBase, self- using #8 wood ISO or FlintBoardH staggered center adhered screws ISO rows 35-inches o.c. Min. 1.5-inch Owens-Corning FOAMULAR, Hy- Therm AP, Hy- Therm(a) AP, Flintlastic Base 20 T FlintBoard ISO, attached 12-inches Flintlastic FR Cap Min. 22 ga. 1 ACFoam-II, Min. /4-inch o.c. in a 4-inch lap 30 T or Flintlastic steel or min. C-12 ENRGY 3, PSI-25, Loose laid DensDeck or Loose laid and 12-inches o.c. in None FR Cap 30 T 30.0 2,500 psi H-Shield, DensDeck Prime two, equally spaced, CoolStar, heat concrete FlintBoardH ISO, H- staggered center welded Shield-P, H-Shield- rows 35-inches o.c. WF, FlintBoardH ISO WF, H-Shield NB or FlintBoardH ISO NB. Min. 1.5-inch Owens-Corning FOAMULAR, Hy- Therm AP, Hy- Therm(a) AP, Flintlastic Base 20 T FlintBoard ISO, attached 12-inches Flintlastic FR Cap Min. 22 ga. 1 ACFoam-II, Min. /4-inch o.c. in a 4-inch lap 30 T or Flintlastic steel or min. C-13 ENRGY 3, PSI-25, Loose laid DensDeck or Loose laid and 12-inches o.c. in None FR Cap 30 T 45.0 2,500 psi H-Shield, DensDeck Prime two, equally spaced, CoolStar, heat concrete FlintBoardH ISO, H- staggered center welded Shield-P, H-Shield rows 24-inches o.c. WF, FlintBoardH ISO WF, H-Shield NB or FlintBoardH ISO NB. Flintlastic SA NailBase attached with OMG Heavy Flintlastic SA Min. 1.5-inch Duty fasteners with 3 Cap, Flintlastic ACFoam-II, in. Ribbed (Optional) SA Cap CoolStar, ENRGY 3, Multi- Min. 22 ga. Galvalume Plates Flintlastic SA Flintlastic SA Cap C-14 Max FA-3, H- Loose laid None N/A 52.5 steel spaced 12-inches Mid Ply, self- FR or Flintlastic Shield, ISO 95+ GL, o.c. in a 2-inch lap adhered SA Cap FR FlintBoard ISO or and 12-inches o.c. in CoolStar, self- FlintBoardH ISO two, equally spaced, adhered staggered center rows Flintlastic SA NailBase attached Min. 1.5-inch with approved base ACFoam-II, sheet fasteners and (Optional) Flintlastic SA Cap ENRGY 3, Multi- plates spaced 12- Min. 22 ga. Flintlastic SA or Flintlastic SA C-15 Max FA-3, H- Loose laid None N/A inches o.c. in a 4- 60.0 steel Mid Ply, self- Cap CoolStar, Shield, ISO 95+ GL, inch lap and 12- adhered self-adhered FlintBoard ISO or inches o.c. in two, FlintBoardH ISO equally spaced, staggered center rows Flintlastic SA NailBase attached with Trufast #12 DP, FlintFast #12 fasteners with Flintlastic SA Min. 1.5-inch Trufast 3” Recessed Cap, Flintlastic ACFoam-II, Metal Insulation and (Optional) SA Cap CoolStar, 19 ENRGY 3, Multi- FlintFast 3” Min. /32-inch Flintlastic SA Flintlastic SA Cap C-16 Max FA-3, H- Loose laid None N/A Insulation Plates 60.0 plywood Mid Ply, self- FR or Flintlastic Shield, ISO 95+ GL, spaced 6-inches o.c. adhered SA Cap FR FlintBoard ISO or in a 3-inch lap and 6- CoolStar, self- FlintBoardH ISO inches o.c. in five, adhered equally spaced, staggered center rows (plates primed with FlintPrime prior to cap installation) ESR-1388 | Most Widely Accepted and Trusted Page 16 of 28 TABLE 2D—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT MECHANICALLY ATTACHED ANCHOR SHEET FOLLOWED BY BONDED INSULATION SYSTEM SUBSTRATE ANCHOR INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE NO. SHEET Type Attach Type Attachment Base Ply Cap UPLIFT Method CAPACITY (psf) 4 D-1 Min. 19/ 3 32-inch Glasbase Base (Optional) Hot Min. /4-inch Hot asphalt One to three plies Hot 60 plywood Sheet, or One or more asphalt FescoBoard applied in hot asphalt asphalt Flintglas layers min. or min. 1/ 2- or heat welded or heat Premium Ply 1.5-inch, inch High welded Sheet Type VI min. 2.0 pcf Density attached with polyisocyanura Fiberboard 11 ga. annular te Roof ring shank Insulation nails & min. 15/ 8-inch dia. tin caps spaced 8-inch o.c. in the 4- inch lap and 8- inch o.c. in three, equally spaced, staggered center rows D-2 Min. 19/ Hot None N/A Black (Optional) Hot 52.5 32-inch Glasbase Base One or more plywood Sheet or layers min. asphalt Diamond One or asphalt Flintglas 1.5-inch Base two plies Premium Ply FlintBoard Sheet or in hot Sheet Type VI ISO, ACFoam- Flintlastic asphalt attached with II, ENRGY 3 or Ultra 11 ga. annular Multi-Max FA- Glass ring shank 3. Maximum SA, self- nails & min. thickness not adhered 15/ 8-inch dia. to exceed 4 tin caps inches. spaced 8-inch o.c. in the 4- inch lap and 8- inch o.c. in three, equally spaced, staggered center rows D-3 Same as System No. D-2, using Heat welded cap sheet Heat 60 welded D-4 Tectum 1 Glasbase Base (Optional) Hot Min. 3/ 60 4-inch Hot asphalt One to three plies Hot Plank Sheet, Flexiglas One or more asphalt FescoBoard applied in hot asphalt asphalt (install per Base Sheet, layers min. or min. 1/ 2- or heat welded or heat ESR-1112) or Flintlastic Base 1.5-inch inch High welded Existing 20 or All FlintBoard Density substrate Weather ISO, ACFoam- Fiberboard Empire Base II, ENRGY 3 or Roof attached with Multi-Max FA- Insulation Twin Loc-Nails 3. Maximum spaced 7-inch thickness not o.c. in the 4- to exceed 4 inch lap and 7- inches. inch o.c. in two, equally spaced, staggered center rows D-5 Tectum 1 Glasbase Base One or more Hot None N/A Black (Optional) Hot 52.5 Plank Sheet, Flexiglas layers min. asphalt Diamond One or asphalt (install per Base Sheet, 1.5-inch Base two plies ESR-1112) or Flintlastic Base FlintBoard Sheet or in hot Existing 20 or All ISO, ACFoam- Flintlastic asphalt substrate Weather II, ENRGY 3 or Ultra Empire Base Multi-Max FA- Glass attached with 3. Maximum SA, self- Twin Loc-Nails thickness not adhered spaced 7-inch to exceed 4 o.c. in the 4- inches. inch lap and 7- inch o.c. in two, equally spaced, staggered center rows D-6 Same as System No. D-5, using Heat welded cap sheet Heat 60 welded ESR-1388 | Most Widely Accepted and Trusted Page 17 of 28 TABLE 2D—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT MECHANICALLY ATTACHED ANCHOR SHEET FOLLOWED BY BONDED INSULATION (Continued) SYSTEM SUBSTRATE ANCHOR INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE NO. SHEET Type Atta Type Attachment Base Ply Cap UPLIFT ch Method CAPACITY (psf) 4 D-7 Existing Glasbase Base Hot Min. 3/ 60 (Optional) 4-inch Hot asphalt One to three plies Hot substrate Sheet, One or asph FescoBoard applied in hot asphalt asphalt Flexiglas Base alt or min. 1/ more 2- or heat welded or heat Sheet, layers min. inch High welded Flintlastic Base 1.5-inch Density 20 or All FlintBoard Fiberboard Weather ISO, Roof Empire Base ACFoam- Insulation attached with II, ENRGY Twin Loc-Nails 3 or Multi- spaced 9-inch Max FA-3. o.c. in the 4- Maximum inch lap and 9- thickness inch o.c. in two, not to equally spaced, exceed 4 staggered inches. center rows D-8 Existing Glasbase Base One or Hot None N/A Black (Optional) Hot 52.5 substrate Sheet, more asph Diamond One or asphalt Flexiglas Base layers min. alt Base two plies Sheet, 1.5-inch Sheet or in hot Flintlastic Base FlintBoard Flintlastic asphalt 20 or All ISO, Ultra Weather ACFoam- Glass SA, Empire Base II, ENRGY self- attached with 3 or Multi- adhered Twin Loc-Nails Max FA-3. spaced 9-inch Maximum o.c. in the 4- thickness inch lap and 9- not to inch o.c. in two, exceed 4 equally spaced, inches. staggered center rows D-9 Same as System No. D-8, using Heat welded cap sheet Heat 60 welded D-10 Tectum 1 Flintlastic Min. 1/ 45 4- Hot None N/A (Optional) (Optional) One ply Plank Base 20 T inch asphalt One ply One ply of of (install per fastened with DensDec of Flintastic Flintlasti ESR-1112) or ES Products k or Flintastic Base 20 c Base Existing Insuldek Loc- DensDec Base 20 T, heat 20 T, substrate Nails or Twin k Prime T, heat welded heat Loc-Nails welded welded (Optional provided the base sheet or ply sheet is installed as the cap sheet) D-11 Min. 19/ Min. 1.5” Min. 1 None Self- 52.5 32-inch All Weather Insta- /4-inch Insta-Stick, One or Plywood at Empire, ACFoam- Stick, DensDeck, OlyBond two layers adhered max 24-inch Flexiglas II, OlyBo DensDeck 500, self- spans attach Base Sheet, ENRGY nd Prime OlyBond adhered 6-inches o.c. Flintlastic 3, 500, Green, (substrate using 8d ring Poly SMS HShield, OlyBo Pliodeck, primed shank nails Base Sheet or Mult- nd ICP with Flint- Flintlastic Max FA- Green, Adhesive Prime Ultra Poly 3, Pliode CR-20 SA) SMS Base FlintBoar ck, or Sheet d ISO or ICP Millennium attached with FlintBoar Adhesi One Step nails & dH ISO ve CR- Foamable tin caps 20 or Adhesive, spaced 8- Millenn 6” o.c. inches o.c. at ium the 3-inch lap One and 8-inches Step o.c. in three, Foama equally ble spaced center Adhesi rows ve, 4” o.c. ESR-1388 | Most Widely Accepted and Trusted Page 18 of 28 TABLE 2D—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT MECHANICALLY ATTACHED ANCHOR SHEET FOLLOWED BY BONDED INSULATION (Continued) SYSTEM SUBSTRATE ANCHOR INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE NO. SHEET Type Attach Type Attachment Base Ply Cap UPLIFT Method CAPACITY (psf) 4 D-12 Min. 19/ 1 32-inch All Weather Min. Insta- Min. /4- Insta-Stick, One or None Self- 60.0 Plywood at Empire, 1.5” Stick, inch OlyBond two layers adhered max 24-inch Flexiglas Base ACFoa OlyBond SECUROC 500, self- spans attach Sheet, m-II, 500, K Gypsum- OlyBond adhered 6-inches o.c. Flintlastic Poly ENRGY OlyBond Fiber Roof Green, (substrate using 8d ring SMS Base 3, Green, Board Pliodeck, primed shank nails Sheet or HShield, Pliodeck ICP with Flint- Flintlastic Ultra Mult- , ICP Adhesive Prime Poly SMS Base Max FA- Adhesiv CR-20 SA) Sheet attached 3, e CR-20 or with nails & FlintBoa or Millennium tin caps spaced rd ISO Millenniu One Step 8-inches o.c. at or m One Foamable the 3-inch lap FlintBoa Step Adhesive, and 8-inches rdH ISO Foamabl 6” o.c. o.c. in three, e equally Adhesiv spaced center e, 4- rows inches o.c. D-13 Min. 19/ None Self- 60.0 32-inch All Weather Min. Insta- None N/A One or Plywood at Empire, 1.5” Stick, two layers adhered max 24-inch Flexiglas Base ACFoa OlyBond Self- spans attach Sheet, m-II, 500, Adhered 6-inches o.c. Flintlastic Poly ENRGY OlyBond (Substrat using 8d ring SMS Base 3, Green, e Primed shank nails Sheet or HShield, Pliodeck with Flint- Flintlastic Ultra Mult- , ICP Prime Poly SMS Base Max FA- Adhesiv SA) Sheet attached 3, e CR-20 with nails & FlintBoa or tin caps spaced rd ISO Millenniu 8-inches o.c. at or m One the 3-inch lap FlintBoa Step and 8-inches rdH ISO Foamabl o.c. in three, e equally Adhesiv spaced center e, 4- rows inches o.c. D-14 Lightweight Yosemite Min. Hot None N/A Yosemite (Optional) Hot 52.5 Cellular Venting Base 1.5-inch asphalt Venting Flintglas mopped Concrete, Sheet attached ACFoa Base Ply Sheet with hot min. 350 psi to the deck m-IV Sheet Type IV, asphalt over using FM-90 spot- Flintglas structural fasteners mopped Premium steel, min. 22 spaced 7-inch with 9- Ply Sheet ga., steel o.c. in the 4- inch wide Type VI, deck inch lap and 7- ribbons of Flintlastic inch o.c. in two ASTM Base 20, equally spaced, D312, Flintlastic staggered rows Type IV Poly SMS in the center of hot Base or the sheet asphalt Flintlastic spaced18 Ultra Poly x18-inch SMS grid Base, hot- asphalt at a rate of 20-40 lbs/sq. D-15 Lightweight Yosemite Min. Hot None N/A Yosemite (Optional) Hot 60.0 Cellular Venting Base 1.5-inch asphalt Venting Flintglas mopped Concrete, Sheet, ACFoa Base Ply Sheet with hot min. 300 psi Flintlastic Poly m-II, Sheet Type IV, asphalt over SMS Base ACFoa strip- Flintglas structural Sheet or m-IV or mopped Premium steel, min. 22 Flintlastic Ultra FlintBoa with 9- Ply Sheet ga., steel Poly SMS Base rd ISO inch wide Type VI, deck Sheet attached ribbons of Flintlastic to the deck ASTM Base 20, using Twin Loc- D312, Flintlastic Nails spaced 9- Type IV Poly SMS inch o.c. in the hot Base or 4-inch lap and asphalt Flintlastic 9-inch o.c. in spaced Ultra Poly two equally 18-inch SMS spaced, o.c. Base, hot- staggered rows asphalt at in the center of a rate of the sheet 20-40 lbs/sq. ESR-1388 | Most Widely Accepted and Trusted Page 19 of 28 TABLE 2E—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT MECHANICALLY ATTACHED BASE SHEET, NONINSULATED ROOF COVER1 ALLOWABLE SYSTEM UPLIFT SUBSTRATE NO. Base Ply Cap CAPACITY (psf) 4 Yosemite Venting Base Sheet, Glasbase Base Sheet or Flintglas 19 Premium Ply Sheet Type VI attached with 11 ga. annular ring (Optional) Min. /32-inch 5 E-1 shank nails & min. 1 /8-inch dia. tin caps spaced 8-inch o.c. in the 4- One or two plies in hot Hot asphalt or heat welded 60.0 plywood inch lap and 8-inch o.c. in three, equally spaced, staggered center asphalt rows Min. 7/ 16-inch OSB, min. 15 Yosemite Venting Base Sheet, Glasbase Base Sheet or All /32-inch (Optional) Weather Empire Base attached with National Nail Cap Nails E-2 plywood or One or two plies in hot Hot asphalt or heat welded 45.0 spaced 6-inch o.c. in the 3-inch lap and 6-inch o.c. in three, equally min. 1-inch asphalt spaced, staggered center rows dimensional lumber Min. 15/ 32-inch OSB, min. 19 Yosemite Venting Base Sheet, Glasbase Base Sheet or All /32-inch (Optional) Weather Empire Base attached with National Nail Cap Nails E-3 plywood or One or two plies in hot Hot asphalt or heat welded 45.0 spaced 6-inch o.c. in the 3-inch lap and 6-inch o.c. in two, equally min. 1-inch asphalt spaced, staggered center rows dimensional lumber Min. 15/ 32-inch OSB, min. 19 Yosemite Venting Base Sheet, Glasbase Base Sheet or All /32-inch (Optional) Weather Empire Base attached with National Nail Cap Nails E-4 plywood or One or two plies in hot Hot asphalt or heat welded 52.5 spaced 6-inch o.c. in the 3-inch lap and 6-inch o.c. in three, equally min. 1-inch asphalt spaced, staggered center rows dimensional lumber Min. 19/ 32-inch OSB, min. 19 Yosemite Venting Base Sheet, Glasbase Base Sheet or All /32-inch (Optional) Weather Empire Base attached with National Nail Cap Nails E-5 plywood or One or two plies in hot Hot asphalt or heat welded 30.0 spaced 9-inch o.c. in the 3-inch lap and 9-inch o.c. in two, equally min. 1-inch asphalt spaced, staggered center rows dimensional lumber Min. 19/ 32-inch OSB, min. 19 Yosemite Venting Base Sheet, Glasbase Base Sheet or All /32-inch (Optional) Weather Empire Base attached with National Nail Cap Nails E-6 plywood or One or two plies in hot Hot asphalt or heat welded 75.0 spaced 6-inch o.c. in the 3-inch lap and 6-inch o.c. in three, equally min. 1-inch asphalt spaced, staggered center rows dimensional lumber Yosemite Venting Base Sheet, Glasbase Base Sheet or All Min. 1-inch (Optional) Weather Empire Base attached with National Nail Cap Nails E-7 dimensional One or two plies in hot Hot asphalt or heat welded 52.5 spaced 6-inch o.c. in the 3-inch lap and 9-inch o.c. in two, equally lumber asphalt spaced, staggered center rows Flintlastic SA Cap, Flintlastic 19 Flintlastic SA NailBase attached with 11 ga. annular ring shank (Optional) Min. /32-inch 5 SA Cap CoolStar or Flintlastic E-8 nails and 1 /8” tin caps spaced 8-inch o.c. in the 3-inch lap and 8- Flintlastic SA Mid Ply, self- 60.0 plywood SA Cap-FR, Flintlastic SA Cap- inch o.c. in three, equally spaced, staggered center rows adhered FR CoolStar self-adhered Tectum 1 Plank Yosemite Venting Base Sheet, Glasbase Base Sheet, Flexiglas (Optional) (install per Base Sheet, Flintlastic Base 20 or All Weather Empire Base E-9 One or two plies in hot Hot asphalt or heat welded 67.5 ESR-1112) attached with Twin Loc-Nails spaced 7-inch o.c. in the 4-inch lap asphalt or existing and 7-inch o.c. in two, equally spaced, staggered center rows substrate Tectum 1 Plank Flintlastic SA NailBase attached with Twin Loc-Nails spaced 7-inch (Optional) (install per E-10 o.c. in the 4-inch lap and 7-inch o.c. in two, equally spaced, Flintlastic SA Mid Ply, self- Self-Adhered 60.0 ESR-1112) staggered center rows adhered or existing substrate Yosemite Venting Base Sheet, Glasbase Base Sheet, Flexiglas (Optional) Existing Base Sheet, Flintlastic Base 20 or All Weather Empire Base E-11 One or two plies in hot Hot asphalt or heat welded 60.0 substrate attached with Twin Loc-Nails spaced 9-inch o.c. in the 4-inch lap asphalt and 9-inch o.c. in two, equally spaced, staggered center rows Yosemite Venting Base Sheet, Glasbase Base Sheet attached with 19 Flintlastic FR Cap 30 T or Min. /32-inch OMG 3” Galvalume Steel Plates with OMG #12 Standard screws Flintlastic Ultra Glass SA, E-12 Flintlastic FR Cap 30 T 67.5 plywood spaced 7-inch o.c. at the 4-inch wide laps and 7-inch o.c. in two self-adhered CoolStar, heat welded equally spaced staggered center rows. Yosemite Venting Base Sheet, Glasbase Base Sheet attached with 19 Black Diamond Base Sheet Flintlastic FR Cap 30 T or Min. /32-inch OMG 3” Round Metal Plates with OMG #12 Fasteners spaced 7- 105.0 E-13 or Flintlastic Ultra Glass SA, Flintlastic FR Cap 30 T plywood inch o.c. at the 4-inch wide laps and 7-inch o.c. in three equally self-adhered CoolStar, heat welded spaced staggered center rows ESR-1388 | Most Widely Accepted and Trusted Page 20 of 28 TABLE 2E—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT MECHANICALLY ATTACHED BASE SHEET, NONINSULATED (Continued) ROOF COVER1 ALLOWABLE SYSTEM UPLIFT SUBSTRATE NO. Base Ply Cap CAPACITY (psf) 4 Yosemite Venting Base Sheet, Glasbase Base Sheet attached with 19 Black Diamond Base Sheet Flintlastic FR Cap 30 T or Min. /32-inch FBC HVHZ Nails and Tin Caps spaced 6-inch o.c. at the 3-inch 82.5 E-14 or Flintlastic Ultra Glass SA, Flintlastic FR Cap 30 T plywood wide laps and 6-inch o.c. in four equally spaced staggered center self-adhered CoolStar, heat welded rows Min. 22 ga. Flintlastic SA Cap, Flintlastic steel form Flintlastic SA NailBase attached with ES Products FM-90 spaced Flintlastic SA PlyBase, self- SA Cap CoolStar or Flintlastic 45.0 E-15 covered with 3-inch lap and 7.5-inch o.c. at two field rows equally spaced adhered SA Cap-FR or Flintlastic SA light weight between the rows Cap-FR CoolStar, self-adhered concrete Flintlastic FR Cap 30, Min. 2,500 psi Flintlastic FR Cap 30 CoolStar, concrete Glasbase Base Sheet attached with ES Products FM-90 spaced Flintlastic FR-P or Flintlastic 60.0 E-16 covered with 7-inch o.c. at 4-inch lap and 7-inch o.c. in two equally spaced None FR-P CoolStar adhered with light weigth staggered center rows Millennium Hurricane Force concrete Membrane Adhesive Flintlastic FR Cap 30, Min. 22 ga. Flintlastic FR Cap 30 CoolStar, steel form Flintlastic Base 20 attached with ES Products FM-90 spaced 7-inch Flintlastic FR-P or Flintlastic 45.0 E-17 covered with o.c. at 4-inch lap and 7-inch o.c. at two equally spaced staggered None FR-P CoolStar adhered with light weight center rows Millennium Hurricane Force concrete Membrane Adhesive Flintlastic FR Cap 30, Min. 22 ga. Flintlastic FR Cap 30 CoolStar, steel form Glasbase Base Sheet attached with ES Products FM-90 spaced Flintlastic FR-P or Flintlastic E-18 covered with 7-inch o.c. at 4-inch lap and 7-inch o.c. at two equally spaced None 52.5 FR-P CoolStar adhered with light weight staggered center rows Millennium Hurricane Force concrete Membrane Adhesive Glasbase Base Sheet, Yosemite Venting Base, Flexiglas Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or (SBS Cap) Hot asphalt or heat Flintlastic Poly SMS Base attached with Simplex MAXX Cap Min. 15/32-inch welded E-19 fasteners spaced 9-inch o.c. at 2-inch lap and 18-inch o.c. at two None 45.0 plywood equally spaced staggered center rows Flintlastic APP Base T (APP Cap) Heat welded Glasbase Base Sheet, Yosemite Venting Base, Flexiglas Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or (SBS Cap) Hot asphalt or heat Min. 15/32-inch Flintlastic Poly SMS Base attached with Simplex MAXX Cap E-20 None welded 52.5 plywood fasteners spaced 9-inch o.c. at 2-inch lap and 12-inch o.c. at two equally spaced staggered center rows Flintlastic APP Base T (APP Cap) Heat welded Glasbase Base Sheet, Yosemite Venting Base, Flexiglas Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or (SBS Cap) Hot asphalt or heat Min. 15/32-inch Flintlastic Poly SMS Base attached with Simplex MAXX Cap E-21 None welded 90.0 plywood fasteners spaced 6-inch o.c. at 2-inch lap and 6-inch o.c. at two equally spaced staggered center rows Flintlastic APP Base T (APP Cap) Heat welded Glasbase Base Sheet, Yosemite Venting Base, Flexiglas Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or (SBS Cap) Hot asphalt or heat Min. 15/32-inch Flintlastic Poly SMS Base attached with Simplex MAXX Cap E-22 None welded 105.0 plywood fasteners spaced 6-inch o.c. at 2-inch lap and 6-inch o.c. at three equally spaced staggered center rows Flintlastic APP Base T (APP Cap) Heat welded ESR-1388 | Most Widely Accepted and Trusted Page 21 of 28 TABLE 2F—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT ALL LAYERS BONDED, INSULATED OR NONINSULATED INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE SYSTEM VAPOR UPLIFT SUBSTRATE NO. BARRIER Type Attach5 Type Attach5 Base Ply Cap CAPACITY (psf) 4 (Optional) One or more Min. 2,500 psi (Optional) layers 1 Min. /2-inch concrete Two plies FlintBoard DuraBoard or One to three plies applied in hot Hot asphalt or F-1 primed with D2178, type ISO or Hot asphalt Hot asphalt 412 min. ¾-inch asphalt heat welded ASTM D41 IV or VI in ACFoam-II FescoBoard primer hot asphalt not to exceed 4 inches in thickness. One or more layers FlintBoard Min. 2,500 psi 1 ISO, Min. /4-inch concrete ACFoam-II, Hot asphalt or DensDeck Hot asphalt or Flintlastic SA (Optional) primed with F-2 None ENRGY 3 or ICP Adhesive primed with ICP Adhesive Mid Ply, self- Flintlastic SA Mid Self-Adhered 192.5 ASTM D41 Multi-Max FA- CR-20 FlintPrime SA CR-20 adhered Ply, self-adhered primer or 3 not to at 0.3 gal/sq. unprimed exceed 4 inches in thickness. One or more Min. 2,500 psi layers 1 Min. /4-inch concrete FlintBoard DensDeck Flintlastic SA (Optional) primed with ISO or Insta-Stik or F-3 None primed with Insta-Stik Mid Ply, self- Flintlastic SA Mid Self-Adhered 120 ASTM D41 ACFoam-II Spray-N-Grip FlintPrime SA adhered Ply, self-adhered primer or not to exceed at 0.3 gal/sq. unprimed 4 inches in thickness Min. 2,500 psi One or more 1 Min. /4-inch concrete layers DensDeck Flintlastic SA (Optional) primed with ENRGY 3 not Insta-Stik or F-4 None primed with Insta-Stik Mid Ply, self- Flintlastic SA Mid Self-Adhered 112.5 ASTM D41 to exceed 4 Spray-N-Grip FlintPrime SA adhered Ply, self-adhered primer or inches in at 0.3 gal/sq. unprimed thickness Min. 2,500 psi One or more 1 Min. /4-inch concrete layers Multi- DensDeck Flintlastic SA (Optional) primed with Max FA-3 not Insta-Stik or F-5 None primed with Insta-Stik Mid Ply, self- Flintlastic SA Mid Self-Adhered 67.5 ASTM D41 to exceed 4 Spray-N-Grip FlintPrime SA adhered Ply, self-adhered primer or inches in at 0.3 gal/sq. unprimed thickness One or more layers FlintBoard Min. 1/ ISO, Millennium 4-inch ACFoam-II, DensDeck Millennium Flintlastic SA (Optional) Min. 2,500 psi Pourable F-6 None ENRGY 3 or primed with Pourable Foam Mid Ply, self- Flintlastic SA Mid Self-Adhered 135 concrete Foam Multi-Max FA- FlintPrime SA Adhesive adhered Ply, self-adhered Adhesive 3 not to at 0.3 gal/sq. exceed 4 inches in thickness One or more layers FlintBoard Min. 1/ ISO, Millennium 4-inch ACFoam-II, DensDeck Millennium One- Flintlastic SA (Optional) Min. 2,500 psi One-Step F-7 None ENRGY 3 or primed with Step Foamable Mid Ply, self- Flintlastic SA Mid Self-Adhered 192.5 concrete Foamable Multi-Max FA- FlintPrime SA Adhesive adhered Ply, self-adhered Adhesive 3 not to at 0.3 gal/sq. exceed 4 inches in thickness (Optional) One or more Min. 1/ layers 4-inch FlintBoard DensDeck Flintlastic SA (Optional) Min. 2,500 psi F-8 None ISO or OlyBond 500 primed with OlyBond 500 Mid Ply, self- Flintlastic SA Mid Self-Adhered 150 concrete ACFoam-II FlintPrime SA adhered Ply, self-adhered not to exceed at 0.3 gal/sq. 4 inches in thickness (Optional) One or more Min. 1/ Min. 2,500 psi layers 4-inch concrete FlintBoard DensDeck Flintlastic SA (Optional) F-9 primed with None ISO or OlyBond 500 primed with OlyBond 500 Mid Ply, self- Flintlastic SA Mid Self-Adhered 120 ASTM D41 ACFoam-II FlintPrime SA adhered Ply, self-adhered primer not to exceed at 0.3 gal/sq. 4 inches in thickness ESR-1388 | Most Widely Accepted and Trusted Page 22 of 28 TABLE 2F—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT ALL LAYERS BONDED, INSULATED OR NONINSULATED (Continued) INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE SYSTEM VAPOR UPLIFT SUBSTRATE NO. BARRIER Type Attach5 Type Attach5 Base Ply Cap CAPACITY (psf) 4 Min. 2,500 psi (Optional) concrete primed Flintlastic SA Mid Flintlastic SA F-10 with ASTM D41 None None N/A None N/A Self-Adhered 550 Ply, self-adhered Mid Ply, self- primer or adhered FlintPrime SA Flintlastic FR Min. 2,500 psi Cap 30 T or concrete primed Flintlastic Base Flintlastic FR F-11 with ASTM D41 None None N/A None N/A 20 T, heat- None 450.0 Cap 30 T primer or welded CoolStar, heat- unprimed welded Flintlastic FR Min. 2,500 psi 1 Min. /4-inch Cap 30 T or concrete primed Min. 1.5-inch Hot mopped Flintlastic Base DensDeck or Hot mopped Flintlastic FR F-12 with ASTM D41 None FlintBoard with hot 20 T, heat- None 480.0 DensDeck with hot asphalt Cap 30 T primer or ISO asphalt welded Prime CoolStar, heat- unprimed welded Min. 19/ 32” plywood at max 24-inch spans Flintlastic SA Mid attach 6-inches Ply or Flintlastic F-13 None None N/A None N/A None Self-adhered 127.5 o.c. using #8 PlyBase, self- wood screws adhered primed with FlintPrime SA Glasbase Base Sheet, All (Optional) Min. 1.5-inch Weather/Empire Min. ¼-inch Flintglas Ply 297.5 Min. 2,500 psi min. Insta-Stik, Insta-Stik, Base Sheet, F-14 None DensDeck Sheet Type IV, Hot Asphalt concrete FlintBoard 12-inch o.c. 12-inch o.c. Flexiglas Base Prime Mopped with ISO Sheet or hot asphalt Flintlastic Base 20, hot asphalt Flintlastic FR F-15 Pliodeck, Pliodek, 12-inch Black Diamond Cap 30 T or 117.5 Min. 1.5-inch 12-inch o.c. Min. ¼-inch o.c. Base Sheet or Flintlastic FR Min. 2,500 psi min. SECUROCK None Flintlastic Ultra None Cap 30 T concrete FlintBoard Gypsum-Fiber ISO Pliodeck, 6- Roof Board Pliodek, 6-inch Glass SA, self- CoolStar, F-16 adhered torched- 217.5 inch o.c. o.c. applied Min. ½-inch Primed min. Structodek F-17 2,500 psi High Density 437.5 concrete Fiberboard or Glasbase Base Fesco Board Sheet, All (Optional) Weather/Empire Flintglas Ply None Hot asphalt None N/A Base Sheet, sheet Type IV, Hot Asphalt Min. ¼-inch Flexiglas Base Mopped with DensDeck, Sheet or hot asphalt DensDeck Flintlastic Base Primed min. Prime, 20, hot asphalt F-18 2,500 psi DensDeck 537.5 concrete DuraGuard or SECUROCK Gypsum-Fiber Roof Board Glasbase Base Sheet, All (Optional) Min. ½-inch Weather/Empire Primed min. Flintglas Ply Structodek Insta-Stik, Base Sheet, 195.0 F-19 2,500 psi None None N/A Sheet Type IV, Hot Asphalt High Density 12-inch o.c. Flexiglas Base concrete Mopped with Fiberboard Sheet or hot asphalt Flintlastic Base 20, hot asphalt Flintlastic FR Cap 30 T or Primed min. Min. 1.5-inch Min. ¼-inch Flintlastic Base Flintlastic FR Insta-Stik, Insta-Stik, 12- F-20 2,500 psi None FlintBoard DensDeck 20 T, torched- None Cap 30 T 302.5 12 inch o.c. inch o.c. concrete ISO Prime applied CoolStar, torched- applied ESR-1388 | Most Widely Accepted and Trusted Page 23 of 28 TABLE 2F—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT ALL LAYERS BONDED, INSULATED OR NONINSULATED (Continued) INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE SYSTEM VAPOR UPLIFT SUBSTRATE NO. BARRIER Type Attach5 Type Attach5 Base Ply Cap CAPACITY (psf) 4 Min. 22 ga. steel covered 60.0 F-21 with light weight Flintlastic FR Cap 30, concrete Glasbase Base Flintlastic FR Cap 30 Sheet adhered CoolStar, Flintlastic Min. 1.5-inch OMG with Millennium None None N/A FR-P or Flintlastic FR- H-Shield CG OlyBond 500 Hurricane None Min. 22 ga. P CoolStar adhered Force steel fastened with Millennium Membrane with Flintfast Hurricane Force Adhesive #14 fasteners Membrane Adhesive F-22 and 3" Round 67.5 Plates at 1:8 ft2 covered with light weight concrete Flintlastic FR Cap 30 Unprimed min. Min. 1.5-inch Insta-Stik Min. 1.5-inch Insta-Stik Flintlastic Ultra or Flintlastic FR Cap F-23 2,500 psi None Multi-Max FA- Roofing Firestone ISO Roofing Glass SA, self- None 135.0 30 CoolStar, Mopped concrete 3 Adhesive 95+ GL Adhesive adhered with hot asphalt (Optional) Flintglas Ply Sheet Type IV, Flintglas Min. 1.5-inch Yosemite Premium Ply ACFoam-II, Venting Base Sheet Type ENRGY 3, Sheet spot- VI, Flintlastic Multi-Max FA- mopped with 9- Base 20, Min. 2,500 psi 3, H-Shield, inch wide Hot mopped F-24 None Hot asphalt None N/A Flintlastic 37.5 concrete ISO 95+ GL, ribbons of with hot asphalt Poly SMS FlintBoard ASTM D312, Base or ISO or Type IV hot Flintlastic FlintBoardH asphalt spaced Ultra Poly ISO 24x24-inch grid SMS Base, hot-asphalt at a rate of 20- 40 lbs/sq. (Optional) Flintlastic Poly SMS Flintlastic FR-P, Base Sheet, Flintlastic FR-P Min. 0.5-inch Flintlastic CoolStar, Flintlastic Flintlastic Base ACFoam-II, H- Ultra Poly Premium FR-P, OlyBond 500 Min. ¼-inch OlyBond 500 20 adhered Primed min. Flintlastic Shield, SMS Base Flintlastic Premium Adhesive or SECUROCK Adhesive or using F-25 2,500 psi SA PlyBase, FlintBoard Sheet or FR-P CoolStar, 75.0 OlyBond 500 Gypsum-Fiber OlyBond 500 FlintBond concrete self-adhered ISO or Flintlastic Flintlastic FR Cap 30 Green Roof Board Green Brush at 1.0 FlintBoardH Base 20 or Flintlastic FR Cap gal/sq. ISO adhered 30 CoolStar adhered using using FlintBond Brush FlintBond at 1.0 gal/sq. Brush at 1.0 gal/sq. F-26 Same as System No. F-25, using Flintlastic Poly SMS Base Sheet and Flintlastic Ultra Poly SMS Base Sheet as the base sheet layer 82.5 Flintlastic FR-P, Flintlastic FR-P (Optional) Min. 0.5-inch Min. 1.5-inch CoolStar, Flintlastic Flintlastic Base Flintlastic ACFoam-II, H- ACFoam-III, H- Premium FR-P, OlyBond 500 OlyBond 500 20 adhered Base 20 Shield, Shield CG, Flintlastic Premium Min. 2,500 psi Adhesive or Adhesive or using adhered F-27 None FlintBoard FlintBoard ISO FR-P CoolStar, 75.0 concrete OlyBond 500 OlyBond 500 FlintBond using ISO or Cold or Flintlastic FR Cap 30 Green Green Brush at 1.0 FlintBond FlintBoardH FlintBoardH or Flintlastic FR Cap gal/sq. Brush at 1.0 ISO ISO Cold 30 CoolStar adhered gal/sq. using FlintBond Brush at 1.0 gal/sq. F-28 Same as System No. F-27, using Flintlastic Poly SMS Base Sheet and Flintlastic Ultra Poly SMS Base Sheet as the base sheet layer 82.5 ESR-1388 | Most Widely Accepted and Trusted Page 24 of 28 TABLE 2F—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT ALL LAYERS BONDED, INSULATED OR NONINSULATED (Continued) INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE SYSTEM VAPOR UPLIFT SUBSTRATE NO. BARRIER Type Attach5 Type Attach5 Base Ply Cap CAPACITY (psf) 4 Flintlastic FR-P, Min. 0.5- (Optional) Flintlastic FR-P inch Min. 1.5-inch Flintlastic Poly CoolStar, Flintlastic Flintlastic Base ACFoam- ACFoam-III, H- SMS Base Sheet, Premium FR-P, OlyBond 500 OlyBond 500 20 adhered Primed min. Flintlastic SA II, H- Shield CG, Flintlastic Ultra Poly Flintlastic Premium Adhesive or Adhesive or using F-29 2,500 psi PlyBase, self- Shield, FlintBoard ISO SMS Base Sheet or FR-P CoolStar, 75.0 OlyBond 500 OlyBond 500 FlintBond concrete adhered FlintBoard Cold or Flintlastic Base 20 Flintlastic FR Cap 30 Green Green Brush at 1.0 ISO or FlintBoardH ISO adhered using or Flintlastic FR Cap gal/sq. FlintBoard Cold FlintBond Brush at 30 CoolStar adhered H ISO 1.0 gal/sq. using FlintBond Brush at 1.0 gal/sq. F-30 Same as System No. F-29, using Flintlastic Poly SMS Base Sheet and Flintlastic Ultra Poly SMS Base Sheet as the base sheet layer 82.5 Flintlastic FR-P, Min. 0.5- (Optional) Flintlastic FR-P inch Flintlastic Poly CoolStar, Flintlastic Flintlastic Base ACFoam- SMS Base Sheet, Premium FR-P, OlyBond 500 Min. ¼-inch OlyBond 500 20 adhered II, H- Flintlastic Ultra Poly Flintlastic Premium Min. 2,500 psi Adhesive or SECUROCK Adhesive or using F-31 None Shield, SMS Base Sheet or FR-P CoolStar, 75.0 concrete OlyBond 500 Gypsum-Fiber OlyBond 500 FlintBond FlintBoard Flintlastic Base 20 Flintlastic FR Cap 30 Green Roof Board Green Brush at 1.0 ISO or adhered using or Flintlastic FR Cap gal/sq. FlintBoard FlintBond Brush at 30 CoolStar adhered H ISO 1.0 gal/sq. using FlintBond Brush at 1.0 gal/sq. F-32 Same as System No. F-31, using Flintlastic Poly SMS Base Sheet and Flintlastic Ultra Poly SMS Base Sheet as the base sheet layer 105.0 Yosemite (Optional) Flintglas Venting Base Ply Sheet Type IV, Min. 1.5- Sheet spot- Flintglas Premium inch mopped with 9- Ply Sheet Type VI, ACFoam- inch wide Flintlastic Base 20, Min. 2,500 psi II, Hot mopped F-33 None Hot asphalt None N/A ribbons of Flintlastic Poly 52.5 concrete ACFoam- with hot asphalt ASTM D312, SMS Base or IV or Type IV hot Flintlastic Ultra Poly FlintBoard asphalt SMS Base, hot- ISO spaced18x18- asphalt at a rate of inch grid 20-40 lbs/sq. (Optional) Flintglas Yosemite Ply Sheet Type IV, Venting Base Flintglas Premium Sheet strip- Ply Sheet Type VI, Min. 1.5- mopped with 9- Flintlastic Base 20, Min. 2,500 psi inch inch wide Hot mopped F-34 None Hot asphalt None N/A Flintlastic Poly 60.0 concrete ACFoam- ribbons of with hot asphalt SMS Base or IV ASTM D312, Flintlastic Ultra Poly Type IV hot SMS Base, hot- asphalt spaced asphalt at a rate of 18-inch o.c. 20-40 lbs/sq. Flintlastic SA NailBase fastened with 11 ga. annular ring shank nails and 1- 5/8” tin caps Flintlastic SA Cap or Min. 19/ spaced 8-inch Flintlastic SA Mid Flintlastic SA Cap F-35 32-inch None None N/A None N/A 60.0 plywood o.c. in a 3-inch Ply, self-adhered CoolStar, self- lap and 8-inch adhered o.c. in three, equally spaced, staggered rows in the center of the sheet Min. 1.5- inch Min. ¼-inch ACFoam- DensDeck II, ENRGY 3, Multi- Primed Flintlastic SA Cap or Primed min. Max FA-3, Hot asphalt or Hot asphalt or Flintlastic SA (Optional) coverboard Flintlastic SA Cap F-36 2,500 psi None H-Shield, ICP Adhesive ICP Adhesive Mid Ply, self- Flintlastic SA Mid 192.5 surface with CoolStar, self- concrete ISO 95+ CR-20 CR-20 adhered Ply, self-adhered FlintPrime SA adhered GL, primer, applied FlintBoard at a rate of 0.25 ISO or gal/sq. FlintBoard H ISO ESR-1388 | Most Widely Accepted and Trusted Page 25 of 28 TABLE 2F—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT ALL LAYERS BONDED, INSULATED OR NONINSULATED (Continued) INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE SYSTEM VAPOR UPLIFT SUBSTRATE NO. BARRIER Type Attach5 Type Attach5 Base Ply Cap CAPACITY (psf) 4 Millennium Millennium One Step One Step Foamable Foamable Flintlastic GTA, Min. 1.5-inch Adhesive, Adhesive, Flintlastic GTA ACFoam-II, H- Millennium Millennium Min. ¼-inch Flintlastic STA Flintlastic STA or CoolStar, Shield, PG-1 Low PG-1 Low Min. 2,500 psi SECUROCK or Flintlastic Flintlastic APP Flintlastic GTA- F-37 None FlintBoard Viscosity Viscosity 252.5 concrete Gypsum-Fiber APP Base T, Base T, heat FR or Flintlastic ISO or Insulation Insulation Roof Board heat welded welded GTA-FR FlintBoardH Adhesive, Adhesive, CoolStar, heat ISO Insta-Stik, Insta-Stik, welded OlyBond 500 OlyBond 500 or OlyBond or OlyBond 500 Green 500 Green Flintlastic GTA, Flintlastic GTA Flintlastic STA Flintlastic STA or CoolStar, Primed min. or Flintlastic Flintlastic APP Flintlastic GTA- F-38 2,500 psi None None N/A None N/A 420.0 APP Base T, Base T, heat FR or Flintlastic concrete heat welded welded GTA-FR CoolStar, heat welded (Optional) Flintglas Yosemite Ply Sheet Type IV, Venting Base Flintglas Premium Sheet strip- Min. 1.5-inch Ply Sheet Type VI, mopped with 9- ACFoam-II, Flintlastic Base 20, Min. 2,500 psi inch wide Hot mopped F-39 None ACFoam-IV or Hot asphalt None N/A Flintlastic Poly 75.0 concrete ribbons of with hot asphalt FlintBoard SMS Base or ASTM D312, ISO Flintlastic Ultra Poly Type IV hot SMS Base, hot- asphalt spaced asphalt at a rate of 18-inch o.c. 20-40 lbs/sq. Yosemite (Optional) Flintglas Venting Base Ply Sheet Type IV, Sheet spot- Flintglas Premium mopped with 9- Ply Sheet Type VI, inch wide Flintlastic Base 20, Min. 2,500 psi Min. 1.5-inch Hot mopped F-40 None Hot asphalt None N/A ribbons of Flintlastic Poly 90.0 concrete ACFoam-IV with hot asphalt ASTM D312, SMS Base or Type IV hot Flintlastic Ultra Poly asphalt SMS Base, hot- spaced18x18- asphalt at a rate of inch grid 20-40 lbs/sq. (Optional) Flintglas Yosemite Ply Sheet Type IV, Venting Base Flintglas Premium Sheet strip- Ply Sheet Type VI, mopped with 9- Flintlastic Base 20, Min. 2,500 psi Min. 1.5-inch inch wide Hot mopped F-41 None Hot asphalt None N/A Flintlastic Poly 112.5 concrete ACFoam-IV ribbons of with hot asphalt SMS Base or ASTM D312, Flintlastic Ultra Poly Type IV hot SMS Base, hot- asphalt spaced asphalt at a rate of 18-inch o.c. 20-40 lbs/sq. Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar, Flintlastic GTS, Flintlastic GTS Black Diamond CoolStar, Primed min. Base Sheet or Flintlastic GTA, F-42 2,500 psi None None N/A None N/A Flintlastic Ultra None 150.0 Flintlastic GTA concrete Glass SA, self- CoolStar, adhered Flintlastic GTA- FR or Flintlastic GTA-FR CoolStar, heat welded Hot mopped with hot asphalt ESR-1388 | Most Widely Accepted and Trusted Page 26 of 28 TABLE 2F—WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT ALL LAYERS BONDED, INSULATED OR NONINSULATED (Continued) INSULATION6 COVERBOARD6 ROOF COVER1 ALLOWABLE SYSTEM VAPOR UPLIFT SUBSTRATE NO. BARRIER Type Attach5 Type Attach5 Base Ply Cap CAPACITY (psf) 4 Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar, Flintlastic GTS, Min. 1.5-inch Flintlastic GTS ACFoam-II, Black Diamond CoolStar, Flintlastic Primed min. H-Shield, Hot Base Sheet or GTA, Flintlastic GTA F-43 2,500 psi None FlintBoard asphalt None N/A Flintlastic Ultra None CoolStar, Flintlastic 375.0 concrete ISO or Glass SA, self- GTA-FR or Flintlastic FlintBoardH adhered GTA-FR CoolStar, ISO heat welded Hot mopped with hot asphalt Min. ¼-inch Flintlastic Ultra (Optional) Flintlastic Flintlastic GMS or Primed min. SECUROCK Poly SMS Base Hot Ultra Poly SMS Base Flintlastic GMS F-44 2,500 psi None None N/A Gypsum- or Flintlastic 487.5 asphalt or Flintlastic Base 20 CoolStar hot mopped concrete Fiber Roof Base 20 T, heat T, heat welded with hot asphalt Board welded For SI: 1 inch = 25.4mm, 1 psf = 47.88 Pa, 1 gal/sq. = 0.41 l/m2, 1 psi = 6.89 kPa. Footnotes for Table 2A thru Table 2F, as applicable: 1Unless otherwise noted, base sheets, ply sheets and cap sheets are as follows:  Base: Hot Asphalt Applied: Glasbase Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Flintglas Ply Sheet Type IV. Heat Welded: Flintlastic Base 20 T or Flintlastic Ultra Poly SMS. Self-Adhered: Black Diamond Base Sheet, Flintlastic Ultra Glass SA, Flintlastic SA Mid Ply, Flintlastic SA PlyBase. Mechanically Fastened: Flintlastic SA NailBase, Flexiglas Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintglas Premium Ply Sheet Type VI, Yosemite Venting Base Sheet or Channel Vent.  Ply: Hot Asphalt Applied: All Weather/Empire Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Flintglas Ply Sheet Type IV, Flintglas Premium Ply Sheet Type VI. Heat Welded: Flintlastic Base 20 T or Flintlastic Ultra Poly SMS. Self-Adhered: Black Diamond Base Sheet, Flintlastic Ultra Glass SA, Flintlastic SA Mid Ply, Flintlastic SA PlyBase.  Cap: Hot Asphalt Applied: Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic Cap 30, Flintlastic Cap 30 CoolStar. Heat Welded: Flintlastic STA, Flintlastic STA Plus, Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA FR, Flintlastic GTA FR CoolStar, Flintlastic GTS, Flintlastic GTS CoolStar, Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar, Flintlastic GTA, Flintlastic GTA CoolStar, Self-Adhered: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic SA Cap-FR, Flintlastic SA Cap-FR CoolStar. 2 Unless otherwise noted, fasteners and plates must be as noted in Table 3. 3Preliminary securement consists of four fasteners per board for boards having any dimension greater than 4 ft and two fasteners per board for boards having a maximum dimension of 4 ft. 4For mechanically fastened insulation, coverboards or base sheets the uplift capacity shall meet or exceed Zone 1 roof cladding design pressure requirements, and the fastener density shall be increased at edge strips and end zones, as defined in ASCE 7. For bonded assemblies, the uplift capacity shall meet or exceed the critical roof cladding design pressure requirements (Zone 2 or 3). 5Bonded polyisocyanurate insulation boards must have a maximum 4 x 4 ft dimension. Insulation Adhesive Application Rates are as follows. Consult adhesive manufacturers published installation instructions for further details.  Hot asphalt at 25-30 lbs/square.  Dow Chemical, Insta-Stik applied in 3/ 4 to 1 inch diameter beads spaced max. 12" o.c.  Adco Millennium Pourable Foam Adhesive applied in 3/ 4 inch wide strips spaced max. 12" o.c.  Adco Millennium One Step Foamable Adhesive applied in 3/ 4 inch diameter beads spaced max. 12" o.c.  Adco Millennium Hurricane Force Adhesive applied in ½ to 3/ 4 inch wide beads spaced max. 12" o.c. (for use with membranes)  Karnak No. 81 Modified Bitumen Adhesive Brush Grade applied in full coverage to approximately 1½ gallons per square. (for use with membranes)  CertainTeed FlintBond Brush Grade adhesive applied in full coverage to approximately 1½ gallons per square. (for use with membranes)  OMG OlyBond 500 applied in 3/ 4 inch diameter beads spaced max. 12" o.c.  ICP Adhesives & Sealants, Inc. CR-20 spray applied in continuous 3 inch wide ribbons spaced max. 12" o.c.  Ashland Pliodeck applied at a rate of 300 to 400 ft² per gallon in 3/ 8 to ½ inch diameter beads spaced max. 12" o.c.  Henry Company #903 Adhesive applied at a rate 1.5 gallons per 100 ft² (for use with membranes) 6Polyisocyanurate insulation must comply with ASTM C1289, Type I or Type II. Perlite insulation must comply with ASTM C728. Wood Fiberboard insulation must comply with ASTM C208. ESR-1388 | Most Widely Accepted and Trusted Page 27 of 28 TABLE 3—INSULATION AND BASE SHEET FASTENERS AND PLATES DECK TYPE ATTACHING FASTENER PLATE SFS Intec Dekfast 12, 14 or #15 Dekfast Galvalume Steel 3" Round or Dekfast Galvalume Steel Hex OMG Standard or Heavy Duty OMG 3" Galvalume Steel Plate or OMG 3 in. Ribbed Galvalume Plate OMG #12 or #14 Roofgrip OMG AccuTrac Plate, AccuTrac Flat Bottom or Flat Bottom Metal Plate Insulation, Cover Altenloh Trufast SIP TP Fastener, Trufast #12 DP Wood or Steel Board or Altenloh Trufast 3" Metal Insulation Plate, FlintFast 3” Insulation Plate Fastener, FlintFast #12, Trufast #14 HD Fastener Base Sheet Altenloh Trufast #12 DPH Fastener Altenloh Trufast 3" Recessed Metal Insulation Plate CertainTeed FlintFast #12 or #14 CertainTeed FlintFast 3" Insulation Plate or FlintFast 3" Round Plates National Nail Cap Nails None SFS Intec Dekfast 14 or DekSpike Dekfast Galvalume Steel 3" Round or Dekfast Galvalume Steel Hex OMG Heavy Duty or CD-10 OMG 3" Galvalume Steel Plate or OMG 3 in. Ribbed Galvalume Plate Insulation, Cover OMG #14 Roofgrip OMG AccuTrac Plate, AccuTrac Flat Bottom or Flat Bottom Metal Plate Concrete Board or Base Sheet Altenloh Trufast #14 HD Fastener Altenloh Trufast 3" Metal Insulation Plate Altenloh Trufast #12 DPH Fastener Altenloh Trufast 3" Metal Insulation Plate CertainTeed FlintFast #14 CertainTeed FlintFast 3" Insulation Plate Concrete or steel Base Sheet Altenloh Tru-Fast #15 EHD Altenloh Tru-Fast 2.4" Barbed Metal Seam Plates Concrete or steel Base Sheet Altenloh FM-90 Basesheet Fastener Plate incorporated with the FM-90 Basesheet Fastener Tectum I Plank (install per Altenloh Trufast Insuldek Loc-Nails or Twin Loc- Base Sheet None ESR-1112) or Nails existing substrate Steel Insulation SFS Intec Dekfast 12 Dekfast Galvalume Steel Hex Plates Steel Cover Board CertainTeed FlintFast #12 CertainTeed FlintFast 3” Insulation Plates ICC-ES Evaluation Report ESR-1388 CBC and CRC Supplement Reissued May 2023 Revised August 2023 This report is subject to renewal May 2024. www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 52 00—Modified Bituminous Sheet Roofing REPORT HOLDER: CERTAINTEED LLC EVALUATION SUBJECT: CERTAINTEED FLINTASTIC MODIFIED BITUMEN ROOF COVERING SYSTEMS 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that CertainTeed Flintastic Modified Bitumen Roof Covering Systems, described in ICC-ES evaluation report ESR-1388, have also been evaluated for compliance with the codes noted below. Applicable code editions:  2022 California Building Code (CBC) For evaluation of applicable chapters adopted by the California Office of Statewide Health Planning and Development (OSHPD) AKA: California Department of Health Care Access and Information (HCAI) and the Division of State Architect (DSA), see Sections 2.1.1 and 2.1.2 below.  2022 California Residential Code (CRC) 2.0 CONCLUSIONS 2.1 CBC: The CertainTeed Flintastic Modified Bitumen Roof Covering Systems, described in Sections 2.0 through 7.0 of the evaluation report ESR-1388, comply with CBC Chapters 15 provided the design and installation are in accordance with the 2021 International Building Code® (IBC) provisions noted in the evaluation and the additional requirements of CBC Chapter 15, as applicable. 2.1.1 OSHPD: The applicable OSHPD Sections and Chapters of the CBC are beyond the scope of this supplement. 2.1.2 DSA: The applicable DSA Sections and Chapters of the CBC are beyond the scope of this supplement. 2.2 CRC: The CertainTeed Flintastic Modified Bitumen Roof Covering Systems, described in Sections 2.0 through 7.0 of the evaluation report ESR-1388, comply with CRC Chapter 9, provided the design and installation are in accordance with the 2021 International Residential Code® (IRC) provisions noted in the evaluation report and the additional requirements of CRC Chapter 9, as applicable. This supplement expires concurrently with the evaluation report, reissued May 2023 and revised August 2023. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2023 ICC Evaluation Service, LLC. All rights reserved. Page 28 of 28 SAFETY DATA SHEET 1. Identification Product identifier Flintlastic GTA Other means of identification Product Identifier CT-10116-2 Recommended use Weatherproofing Recommended restrictions None known. Manufacturer/Importer/Supplier/Distributor information Manufacturer Company name CertainTeed Corporation Address 20 Moores Road Malvern, PA 19355 United States Telephone +1 610-893-6000 E-mail www.certainteed.com Emergency phone number 3E Global Incident Response 1 760 476 3962 1 866 519 4752 (Toll Free) Access Code: 336250 2. Hazard(s) identification Physical hazards Not classified. Health hazards Not classified. Environmental hazards Not classified. OSHA defined hazards Not classified. Label elements Hazard symbol None. Signal word None. Hazard statement The product does not meet the criteria for classification. Precautionary statement Prevention Observe good industrial hygiene practices. Response Wash hands after handling. Storage Store away from incompatible materials. Disposal Dispose of waste and residues in accordance with local authority requirements. Hazard(s) not otherwise None known. classified (HNOC) Supplemental information Processing and/or heating of this product might generate fumes that are potentially irritating to the respiratory system and the eye. 3. Composition/information on ingredients Mixtures Chemical name Common name and synonyms CAS number % Asphalt 8052-42-4 15 - 40 Ground Calcium Carbonate 1317-65-3 10 - 30 Polypropylene 9003-07-0 5 - 10 1-Propene polymer with ethene 9010-79-1 1 - 5 Carbon black 1333-86-4 0.1 - 1 Quartz (Impurity) 14808-60-7 0.1 - 1 Material name: Flintlastic GTA SDS US 6765 Version #: 01 Issue date: 10-28-2024 1 / 7 Composition comments The exact concentrations of the above listed chemicals are being withheld as a trade secret. All concentrations are in percent by weight. Non-classification as a carcinogen is based on the non-respirable form of the product. 4. First-aid measures Inhalation Respiration of particles is unlikely during normal use. Move to fresh air. Call a physician if symptoms develop or persist. Skin contact Wash off with soap and water. Get medical attention if irritation develops and persists. Eye contact Unlikely route of exposure. Rinse with water. Get medical attention if irritation develops and persists. Ingestion Unlikely route of exposure. Rinse mouth. Drink plenty of water. Get medical attention if symptoms occur. Most important Exposure to fume during installation may produce coughing. symptoms/effects, acute and delayed Indication of immediate Treat symptomatically. medical attention and special treatment needed General information Ensure that medical personnel are aware of the material(s) involved, and take precautions to protect themselves. 5. Fire-fighting measures Suitable extinguishing media Foam. Dry powder. Carbon dioxide (CO2). Unsuitable extinguishing Do not use water jet as an extinguisher, as this will spread the fire. media Specific hazards arising from During fire, gases hazardous to health may be formed. the chemical Special protective equipment Self-contained breathing apparatus and full protective clothing must be worn in case of fire. and precautions for firefighters Fire fighting Not applicable. equipment/instructions Specific methods Use standard firefighting procedures and consider the hazards of other involved materials. General fire hazards No unusual fire or explosion hazards noted. 6. Accidental release measures Personal precautions, Ensure adequate ventilation. Keep unnecessary personnel away. For personal protection, see protective equipment and section 8 of the SDS. emergency procedures Methods and materials for Pick up mechanically; Send for recovery or disposal in suitable receptacles. For waste disposal, containment and cleaning up see section 13 of the SDS. Environmental precautions Avoid release to the environment. 7. Handling and storage Precautions for safe handling Provide adequate ventilation. Observe good industrial hygiene practices. Conditions for safe storage, Store away from incompatible materials (see Section 10 of the SDS). including any incompatibilities 8. Exposure controls/personal protection Occupational exposure limits The following constituents are the only constituents of the product which have a PEL, TLV or other recommended exposure limit. At this time, the other constituents have no known exposure limits. US. OSHA Table Z-1 Permissible Exposure Limits (PEL) for Air Contaminants (29 CFR 1910.1000) Components Type Value Form Carbon black (CAS PEL 3.5 mg/m3 1333-86-4) Ground Calcium Carbonate PEL 5 mg/m3 Respirable fraction. (CAS 1317-65-3) 15 mg/m3 Total dust. Material name: Flintlastic GTA SDS US 6765 Version #: 01 Issue date: 10-28-2024 2 / 7 US. OSHA Table Z-1 Permissible Exposure Limits (PEL) for Air Contaminants (29 CFR 1910.1000) Components Type Value Form Quartz (Impurity) (CAS PEL 0.05 mg/m3 Respirable dust. 14808-60-7) US. OSHA Table Z-3 Permissible Exposure Limits (PEL) for Mineral Dusts (29 CFR 1910.1000) Components Type Value Form Carbon black (CAS TWA 5 mg/m3 Respirable fraction. 1333-86-4) 15 mg/m3 Total dust. 50 mppcf Total dust. 15 mppcf Respirable fraction. Ground Calcium Carbonate TWA 5 mg/m3 Respirable fraction. (CAS 1317-65-3) 15 mg/m3 Total dust. 50 mppcf Total dust. 15 mppcf Respirable fraction. Quartz (Impurity) (CAS TWA 0.1 mg/m3 Respirable. 14808-60-7) 2.4 mppcf Respirable. US. ACGIH Threshold Limit Values (TLV) Components Type Value Form Asphalt (CAS 8052-42-4) TWA 0.5 mg/m3 Inhalable fume. Carbon black (CAS TWA 3 mg/m3 Inhalable fraction. 1333-86-4) Quartz (Impurity) (CAS TWA 0.025 mg/m3 Respirable fraction. 14808-60-7) NIOSH. Immediately Dangerous to Life or Health (IDLH) Values, as amended Components Type Value Carbon black (CAS IDLH 1750 mg/m3 1333-86-4) Quartz (Impurity) (CAS IDLH 50 mg/m3 14808-60-7) US. NIOSH: Pocket Guide to Chemical Hazards Recommended Exposure Limits (REL) Components Type Value Form Asphalt (CAS 8052-42-4) Ceiling 5 mg/m3 Fume. Carbon black (CAS TWA 0.1 mg/m3 1333-86-4) Ground Calcium Carbonate TWA 5 mg/m3 Respirable. (CAS 1317-65-3) 10 mg/m3 Total Quartz (Impurity) (CAS TWA 0.05 mg/m3 Respirable dust. 14808-60-7) Biological limit values ACGIH Biological Exposure Indices (BEI) Components Value Determinant Specimen Sampling Time Asphalt (CAS 8052-42-4) 2.5 µg/l 1-Hydroxypyre Urine * ne, with hydrolysis (1-HP) * - For sampling details, please see the source document. Appropriate engineering Good general ventilation should be used. Ventilation rates should be matched to conditions. If controls applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Individual protection measures, such as personal protective equipment Eye/face protection Wear safety glasses with side shields (or goggles). Material name: Flintlastic GTA SDS US 6765 Version #: 01 Issue date: 10-28-2024 3 / 7 Skin protection Hand protection Wear protective gloves. Other Normal work clothing (long sleeved shirts and long pants) is recommended. Respiratory protection When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. Thermal hazards Wear appropriate thermal protective clothing, when necessary. General hygiene Always observe good personal hygiene measures, such as washing after handling the material considerations and before eating, drinking, and/or smoking. Routinely wash work clothing and protective equipment to remove contaminants. 9. Physical and chemical properties Appearance Physical state Solid. Form Solid. Color Black. Odor Petroleum-like. Odor threshold Not available. pH Not available. Melting point/freezing point Not available. Initial boiling point and boiling Not available. range Flash point Not available. Evaporation rate Not available. Flammability (solid, gas) Not available. Upper/lower flammability or explosive limits Explosive limit - lower (%) Not available. Explosive limit - upper (%) Not available. Vapor pressure Not available. Vapor density Not available. Relative density Not available. Solubility(ies) Solubility (water) Insoluble Partition coefficient Not available. (n-octanol/water) Auto-ignition temperature Not available. Decomposition temperature Not available. Viscosity Not available. Other information Explosive properties Not explosive. Oxidizing properties Not oxidizing. 10. Stability and reactivity Reactivity The product is stable and non-reactive under normal conditions of use, storage and transport. Chemical stability Material is stable under normal conditions. Possibility of hazardous No dangerous reaction known under conditions of normal use. reactions Conditions to avoid Contact with incompatible materials. Incompatible materials Acids. Fluorine. Hazardous decomposition No hazardous decomposition products are known. products 11. Toxicological information Information on likely routes of exposure Inhalation None known. Material name: Flintlastic GTA SDS US 6765 Version #: 01 Issue date: 10-28-2024 4 / 7 Skin contact No adverse effects due to skin contact are expected. Eye contact None known. Ingestion Expected to be a low ingestion hazard. Symptoms related to the Processing or heating may cause respiratory irritation and/or coughing. physical, chemical and toxicological characteristics Information on toxicological effects Acute toxicity Not known. Components Species Test Results Asphalt (CAS 8052-42-4) Acute Dermal LD50 Rabbit > 2000 mg/kg Oral LD50 Rat > 5000 mg/kg Carbon black (CAS 1333-86-4) Acute Oral LD50 Rat > 8000 mg/kg Skin corrosion/irritation Due to partial or complete lack of data the classification is not possible. Serious eye damage/eye Due to partial or complete lack of data the classification is not possible. irritation Respiratory or skin sensitization Respiratory sensitization Due to partial or complete lack of data the classification is not possible. Skin sensitization Due to partial or complete lack of data the classification is not possible. Germ cell mutagenicity Due to partial or complete lack of data the classification is not possible. Carcinogenicity Reference to chemical component(s) listed are based on unbound respirable particles and are not generally applicable to product as supplied. IARC Monographs. Overall Evaluation of Carcinogenicity Asphalt (CAS 8052-42-4) 2B Possibly carcinogenic to humans. Carbon black (CAS 1333-86-4) 2B Possibly carcinogenic to humans. Polypropylene (CAS 9003-07-0) 3 Not classifiable as to carcinogenicity to humans. Quartz (Impurity) (CAS 14808-60-7) 1 Carcinogenic to humans. OSHA Specifically Regulated Substances (29 CFR 1910.1001-1053) Quartz (Impurity) (CAS 14808-60-7) Cancer US. National Toxicology Program (NTP) Report on Carcinogens Asphalt (CAS 8052-42-4) Known To Be Human Carcinogen. Carbon black (CAS 1333-86-4) Known To Be Human Carcinogen. Quartz (Impurity) (CAS 14808-60-7) Known To Be Human Carcinogen. Reproductive toxicity Due to partial or complete lack of data the classification is not possible. Specific target organ toxicity - Due to partial or complete lack of data the classification is not possible. single exposure Specific target organ toxicity - Due to partial or complete lack of data the classification is not possible. repeated exposure Aspiration hazard Due to partial or complete lack of data the classification is not possible. Chronic effects Prolonged inhalation may be harmful. Prolonged exposure may cause chronic effects. 12. Ecological information Ecotoxicity The product is not classified as environmentally hazardous. However, this does not exclude the possibility that large or frequent spills can have a harmful or damaging effect on the environment. Persistence and degradability No data is available on the degradability of any ingredients in the mixture. Bioaccumulative potential No data available. Mobility in soil No data available. Material name: Flintlastic GTA SDS US 6765 Version #: 01 Issue date: 10-28-2024 5 / 7 Other adverse effects No other adverse environmental effects (e.g. ozone depletion, photochemical ozone creation potential, endocrine disruption, global warming potential) are expected from this component. 13. Disposal considerations Disposal instructions Collect and reclaim or dispose in sealed containers at licensed waste disposal site. Local disposal regulations Dispose in accordance with all applicable regulations. Hazardous waste code The waste code should be assigned in discussion between the user, the producer and the waste disposal company. Waste from residues / unused Dispose of in accordance with local regulations. Empty containers or liners may retain some products product residues. This material and its container must be disposed of in a safe manner (see: Disposal instructions). Contaminated packaging Since emptied containers may retain product residue, follow label warnings even after container is emptied. Empty containers should be taken to an approved waste handling site for recycling or disposal. 14. Transport information DOT Not regulated as dangerous goods. IATA Not regulated as dangerous goods. IMDG Not regulated as dangerous goods. Transport in bulk according to Not applicable. Annex II of MARPOL 73/78 and the IBC Code 15. Regulatory information US federal regulations This product is not known to be a "Hazardous Chemical" as defined by the OSHA Hazard Communication Standard, 29 CFR 1910.1200. Toxic Substances Control Act (TSCA) All components of the mixture on the TSCA 8(b) inventory are designated “active”. TSCA Section 12(b) Export Notification (40 CFR 707, Subpt. D) Not regulated. CERCLA Hazardous Substance List (40 CFR 302.4) Not listed. SARA 304 Emergency release notification Not regulated. OSHA Specifically Regulated Substances (29 CFR 1910.1001-1053) Quartz (Impurity) (CAS 14808-60-7) Cancer lung effects immune system effects kidney effects Superfund Amendments and Reauthorization Act of 1986 (SARA) SARA 302 Extremely hazardous substance Not listed. SARA 311/312 Hazardous No chemical SARA 313 (TRI reporting) Not regulated. Other federal regulations Clean Air Act (CAA) Section 112 Hazardous Air Pollutants (HAPs) List Asphalt (CAS 8052-42-4) Clean Air Act (CAA) Section 112(r) Accidental Release Prevention (40 CFR 68.130) Not regulated. Safe Drinking Water Act Not regulated. (SDWA) Material name: Flintlastic GTA SDS US 6765 Version #: 01 Issue date: 10-28-2024 6 / 7 US state regulations California Proposition 65 WARNING: This product can expose you to chemicals including Asphalt, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov. California Proposition 65 - CRT: Listed date/Carcinogenic substance Asphalt (CAS 8052-42-4) Listed: January 1, 1990 Carbon black (CAS 1333-86-4) Listed: February 21, 2003 Quartz (Impurity) (CAS 14808-60-7) Listed: October 1, 1988 International Inventories Country(s) or region Inventory name On inventory (yes/no)* Australia Australian Inventory of Industrial Chemicals (AICIS) Yes Canada Domestic Substances List (DSL) No Canada Non-Domestic Substances List (NDSL) Yes China Inventory of Existing Chemical Substances in China (IECSC) Yes Europe European Inventory of Existing Commercial Chemical No Substances (EINECS) Europe European List of Notified Chemical Substances (ELINCS) No Japan Inventory of Existing and New Chemical Substances (ENCS) Yes Korea Existing Chemicals List (ECL) Yes New Zealand New Zealand Inventory Yes Philippines Philippine Inventory of Chemicals and Chemical Substances Yes (PICCS) Taiwan Taiwan Chemical Substance Inventory (TCSI) Yes United States & Puerto Rico Toxic Substances Control Act (TSCA) Inventory Yes *A "Yes" indicates that all components of this product comply with the inventory requirements administered by the governing country(s) A "No" indicates that one or more components of the product are not listed or exempt from listing on the inventory administered by the governing country(s). 16. Other information, including date of preparation or last revision Issue date 10-28-2024 Version # 01 Disclaimer CertainTeed Corporation cannot anticipate all conditions under which this information and its product, or the products of other manufacturers in combination with its product, may be used. It is the user’s responsibility to ensure safe conditions for handling, storage and disposal of the product, and to assume liability for loss, injury, damage or expense due to improper use. The information in the sheet was written based on the best knowledge and experience currently available. Material name: Flintlastic GTA SDS US 6765 Version #: 01 Issue date: 10-28-2024 7 / 7 Permit #: 6410 Permit Date: 03/14/25 Permit Type: COMMERCIAL RE-ROOF Project Name: City of Arlington Applicant Name: S&S Roofing, LLC Applicant Address: 104 S West Ave Applicant, City, State, Zip: Arlington, WA 98223 Contact: Jami King Phone: 360-386-9903 Email: jamisandsroofing@hotmail.com Scope of Work: Remove existing roofing and install Certainteed granulated torchdown system Valuation: 63500.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: CIC Permit Issued: 05/05/2025 Permit Expires: 10/31/2025 Form Permit Type: COMMERCIAL RE-ROOF Status: COMPLETE Assigned To: Kristin Foster Property Parcel # Address Legal Description Owner Name Owner Phone Zoning CITY OF 184 31051500401203 6205 188TH PL NE ARLINGTON GOVERNMENT AIRPORT Contractors Contractor Primary Contact Phone Address Contractor Type License License # 104 S West CONSTRUCTION S&S Roofing LLC jamisandroofing@hotmail.com 3603869903 COA 602 934 849 Ave CONTRACTOR 104 S West CONSTRUCTION Construction S&S Roofing LLC jamisandroofing@hotmail.com 3603869903 SSROOSR918MM Ave CONTRACTOR Contractor Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status R00.1 RE-ROOF 08/29/2025 09/03/2025 09/02/2025 BUILDING Approved FINAL Plan Reviews Date Review Type Description Assigned To Review Status Approved with 03/14/2025 COMMERCIAL RE-ROOF BUILDING Conditions Fees Fee Description Notes Amount Processing/Technology ($25.00) State Surcharge - Commercial Commercial Only $25.00 Re-Roof Commercial Table 4.1 ($1,110.48) Re-Roof Commercial Plan Review Plan Review ($100.00) Processing/Technology $25.00 State Surcharge - Commercial Commercial Only ($25.00) Re-Roof Commercial Table 4.1 $1,110.48 Re-Roof Commercial Plan Review Plan Review $100.00 Total $0.00 Attached Letters Date Letter Description 05/05/2025 Building Permit Notes Date Note Created By: 08/29/2025 sent expiration notice Hannah Hardwick 05/02/2025 Permit Fees were waived by City Council. Kristin Foster Uploaded Files Date File Name 05/05/2025 25771474-20250505_BLD6410_IssuedPermit.pdf 03/14/2025 24909693-20250311_BLD6410_Application.pdf TECHNICAL DATA SHEET Flintlastic® GTA APP-modified bitumen polyester cap sheet with mineral surface PRODUCT INFORMATION Flintlastic® GTA is designed for use as a cap membrane in systems over various types of substrates for both new construction and reroofing installations. It is suitable for most low sloped roof decks and may be used for roof system flashings. Limitations: Flintlastic GTA is intended for torch application only and should not be exposed to adhesives or solvent based materials. Additional specifications and precautions are contained in the CertainTeed Commercial Roof Systems Specifications. Product Composition and Features: Flintlastic GTA products are manufactured on state-of-the-art dedicated KEY PRODUCT DETAILS roofing lines that were exclusively designed for the production of modified bitumen roofing membranes. Roll Dimensions: 39-3/8" X 32'10" This 157 mil membrane is manufactured with a resilient Nominal Coverage: One square polyester reinforcement, offering exceptional durability Approximate Weight: 103 Ibs. per roll and resistance to weathering. Flintlastic modified bitumen roofing systems must be Top Surface: Mineral granules applied in accordance with installation procedures Back Surface: Torchable polyethylene film contained in the CertainTeed Commercial Roof Systems Specifications. The following information is intended Packaging: 25 rolls per pallet for general information purposes only and is not Non-oxidized (flux) asphalt, all-inclusive. blended with various Preparation: Substrates to receive a roof system must Compound: thermoplastic atactic be firmly attached, smooth, dry, clean and free of sharp polypropylene polymers and projections and depressions. Substrates requiring priming co-polymers. must be primed with asphalt primer such as FlintPrime® High performance, stress- and be allowed to completely dry. Substrates must provide Reinforcement: resistant polyester mat. positive drainage. Roof must be tapered to drains. Installation: Install one ply of Glasbase™ or other not less than 3' apart. Side and end laps should be inspected CertainTeed approved alternate base sheet lapping 2" on to ensure a minimum 3/8" flow of modified compound has sides and 4" on ends. Attach base sheet as specified in been achieved. the CertainTeed Commercial Roof Systems Specifications. Apply base sheet in such a manner as to provide and APPLICATION METHOD maintain a minimum 6" offset between side and end laps of base ply and Flintlastic finishing membrane. Over the base ply, install one ply of Flintlastic GTA lapping 3" on sides and 6" on ends, with end laps diagonally staggered CODES AND APPROVALS Torch ASTM TEXAS DEPARTMENT INTERNATIONAL OF INSURANCE Underwriters Florida Building Code Meets or exceeds (RC-47) Laboratories for use in Statewide (FL 2533 and Product code ID ASTM D6222, various Class A, B and C FL 16709) 0668-0008 Grade G, Type I roof assemblies PRODUCT INFORMATION (CONT'D) Precautions: Cold weather applications require special Maintenance: CertainTeed recommends regular roof handling to prevent damage to the rolls and ensure maintenance and inspection to determine the condition satisfactory installation. Do not apply roofing systems over of drains, flashings and other similar items, and to prolong improperly prepared substrates or substrates that contain the life expectancy of the roof system. moisture. Follow all safety recommendations relating to the use and maintenance of liquid propane gas torches and equipment. Refer to the CertainTeed Commercial Roof Systems Specifications for additional safety information. PHYSICAL PROPERTIES Test Description Test Method Results* Solar Reflectance Index (SRI) Initial/Aged: ASTM E1980 27/28 Softening Point: ASTM D36 310°F Tensile Strength: ASTM D5147 @ 73.4 +/- 3.6°F MD/XD 100/60 lbs./in. @ 0 +/- 3.6°F MD/XD 130/80 lbs./in. Elongation: ASTM D5147 @ 73.4 +/- 3.6°F MD/XD 45%/55% @ 0 +/- 3.6°F MD/XD 30%/20% Dimensional Stability: ASTM D5147 MD/XD 0.5%/0.3% Low Temperature Flex: ASTM D5147 Pass @ 8°F Compound Stability: ASTM D5147 250°F Thickness: ASTM D5147 4.0 mm (157 mils) Tear Strength: ASTM D5147 @ 73.4 +/- 3.6°F MD/XD 130/90 lbs. *NOTE: Published results are nominal production values confirmed by independent laboratory testing. STORAGE AND HANDLING and Silver Star Contractors are eligible to apply for NDL warranties on specific roof projects. For more information, Rolls should be stored upright, off the ground and see CertainTeed Commercial Roof Systems Specifications completely protected from the weather. Manual or contact Commercial Roofing Technical Services. For detailed installation instructions and precautions, refer to the TECHNICAL ASSISTANCE AND SERVICES CertainTeed Commercial Roof Systems CertainTeed provides technical assistance in the design, Specifications Manual or contact selection, specification and application guidelines of Commercial Roofing Technical Services. CertainTeed’s Commercial Roof Systems. Architectural and field representatives are available for consultation within WARRANTIES each region. CertainTeed offers Limited (product only) and No Dollar For more information, contact CertainTeed Commercial Limit (NDL, product and workmanship) warranties. Roofing Technical Services at 800-396-8134 x2. Warranty type and duration is dependent on roof system configuration and contractor selection. CertainTeed Gold CertainTeed CEILINGS • GYPSUM • INSUL ATION • ROOFING • SIdING • TRIM 20 Moores Road, Malvern, PA 19355 Professional: 800-233-8990 Consumer: 800-782-8777 certainteed.com ©07/24 CertainTeed, Code No. 01-11-4294-NA-EN