Loading...
HomeMy WebLinkAbout20404 67th Ave Ne Ste B_BLD6682_2025 Job Name: Tag# Submittal Data Sheet FTX18AXVJU / RX18AXVJU 1.5-Ton Wall Mounted Heat Pump System Efficiency Cooling Heating SEER 18.5 HSPF 9.0 EER 12.5 COP 3.60 Performance Cooling (Btu/hr) Rated (Min/Max) 18,000 (5,500 / 20,000) Sensible @ AHRI 14,480 Moisture Removal gal/h 0.41 Standard Operating Range 50°F – 115°F Extended Operating Range* -4°F – 115°F Rated Cooling Conditions: Indoor: 80°F DB/67°F WB Outdoor: 95°F DB/75°F WB *With field settings and wind baffle Complete warranty details available from your local dealer or at Heating (Btu/hr) www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of 1:@ 47° Rated (Min/Max) 21,600 (5,500 / 24,000) installation. Online registration is not required in California or Quebec. 2: @ 17° Rated 12,700 If product is installed in a commercial application, limited warranty Operating Range 5°F – 65°F period is 5 years. 1: Rated Heating Conditions: Indoor: 70°F DB/60°F WB Outdoor: 47°F DB/43°F WB Indoor Specifications 2: Rated Heating Conditions: Indoor: 70°F DB/60°F WB Outdoor: 17°F DB/15°F WB Cooling Heating H M H M Electrical Airflow Rate (cfm) 716 605 716 605 208/60/1 230/60/1 L SL L SL System MCA 16.4 16.4 467 395 467 395 System MFA 20.0 20.0 Sound (dBA) 49 / 44 / 38 / 33 49 / 42 / 37 / 33 Compressor RLA 16.0 16.0 H / M / L / SL Outdoor fan motor FLA .99 .99 Dimensions (H × W × D) (in) 11-11/16 × 39-1/2 × 11-1/3 Outdoor fan motor W 128 128 Weight (Lbs) 31 Indoor fan motor FLA .50 .50 Outdoor Specifications Indoor fan motor W 35 35 MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A) Compressor Hermetically Sealed Swing Type RLA: Rated load amps (A) W: Fan motor rated output (W) Refrigerant R-410A Factory Charge (Lbs) 3.20 Piping Liquid (in) 1/4 Refrigerant Oil PVE (FVC50K) Gas (in) 1/2 Cooling Heating Airflow Rate (cfm) Drain (in) 3/4 H 2,005 H 1,905 Max. Interunit Piping Length (ft) 98.4 Sound Pressure Level (dBA) 54 Max. Interunit Height Difference (ft) 65.625 Dimensions (H × W × D) (in) 27-13/32 × 36-5/8 × 13-13/16 Chargeless (ft) 32.8 Weight (Lbs) 101 Additional Charge of Refrigerant (oz/ft) .21 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: January 2022 Page 1 of 4 FTX18AXVJU Dimensional Data Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: January 2022 Page 2 of 4 RX18AXVJU Dimensional Data Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: January 2022 Page 3 of 4 Optional Accessories Indoor Unit Included Part Number Description BRP072A43 Wireless Interface Adaptor AZAI6WSCDKB DKN Residential Cloud Wi-Fi Adaptor for Single- and Multi-Zone System (S21) AZAI6WSPDKC DKN Plus Interface BRC51D61 Wired Remote Controller Kit (32.8ft cable included) BRC944B2 Wired Remote Controller BRCW901A08 Wired Remote Controller Cable – 25ft BRCW901A03 Wired Remote Controller Cable – 10ft DACA-CP1-1 Inline Condensate Pump (Fits inside all Daikin wall & floor mount units) DACA-CP4-1 External Condensate Pump Outdoor Unit Included Part Number Description DACA-WB-1 Powder-Coated Wall-Mounted Bracket KPW063B4E Air Adjustment Grille KEH063A4EA Daikin BML Drain Pan Heater Large (incl. RX_AXVJU) Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: January 2022 Page 4 of 4 From: Sabrina Kennard To: Shared-VM-CED Cc: permits@cmheating.com Subject: 6682 Date: Thursday, September 11, 2025 12:56:23 PM Attachments: image001.png image002.png image003.png image004.png image005.png This message is from an External Sender This message came from outside the City of Arlington Hello! Customer has decided to cancel the project so permit is no longer needed. Can we please get the process of cancelling the permit and a refund going? Thank you. Regards, Sabrina Kennard Permit Coordinator 425-259-0550 CM Heating Sabrina.kennard@cmheating.com www.cmheating.com 1500 Industry St Suite #200, Everett, WA 98203 Permit #: 6682 Permit Date: 08/19/25 Permit Type: COMMERCIAL MECHANICAL Project Name: Crowther Applicant Name: CM Heating Applicant Address: 1500 Industry St #200 Applicant, City, State, Zip: Everett, Wa, 98203 Contact: Sabrina Kennard Phone: 4252590550 Email: permits@cmheating.com Scope of Work: Adding single zone ductless heat pump Valuation: 7600.00 Square Feet: 0 Number of Stories: 0 Construction Type: VB Occupancy Group: B; Business ID Code: Permit Issued: 08/21/2025 Permit Expires: 02/20/2026 Form Permit Type: COMMERCIAL MECHANICAL Status: VOID/WITHDRAWN Assigned To: Hannah Hardwick Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 20404 67th Avenue NE STE 31051000404400 STC Properties, LLC 638 Mini-Warehouse B Contractors Contractor Primary Contact Phone Address Contractor Type License License # 1500 INDUSTRY CONSTRUCTION Plumbing CM HEATING INC 425-259-0550 CMHEAHL750LP ST STE 200 CONTRACTOR Contractor 1500 INDUSTRY CONSTRUCTION Construction CM HEATING INC 425-259-0550 CMHEAHL751W ST STE 200 CONTRACTOR Contractor 1500 INDUSTRY CONSTRUCTION CM HEATING INC 425-259-0550 UBI 605890285 ST STE 200 CONTRACTOR Plan Reviews Date Review Type Description Assigned To Review Status COMMERCIAL 08/19/2025 BUILDING In Review MECHANICAL Fees Fee Description Notes Amount Mechanical Commercial Plan Review Table 4-1 $143.21 Credit Card Service $4.30 Heat Pump/Heat Exchangers $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Credit Card Service $2.25 Total $224.76 Attached Letters Date Letter Description 08/21/2025 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 08/19/2025 Matt Zivanov 240548082 Hannah Hardwick $4.30 XBP Conf: 08/19/2025 $143.21 240548082 08/21/2025 Matt Zivanov 240820128 Hannah Hardwick $2.25 XBP Conf: 08/21/2025 $75.00 240820128 Outstanding Balance $0.00 Notes Date Note Created By: 08/20/2025 emailed applicant additional questions Kevin had. Hannah Hardwick Uploaded Files Date File Name 09/11/2025 28228394-Cancellation.pdf 08/21/2025 27933073-2025_BLD6682_Issued Permit.pdf 08/20/2025 27910200-20250820_BLD6682_Additional Information.pdf 08/19/2025 27878366-20250819_BLD6682_Specs.pdf 08/19/2025 27878367-20250819_BLD6682_Site Plan.pdf 08/19/2025 27878368-20250819_BLD6682_App.pdf