Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
517 N Macleod Ave_BLD6628_2025
RESIDENTIAL MECHANICAL APPLICATION Community and Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit: ï² New Installation ï² Addition/Alteration/Repair ï² Gas Piping Property Address: Project Valuation: Lot #: Parcel ID No.: Preferred Contact: ï² Owner ï² Contractor Project Description: Owner Name: Home No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Contractor Name: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information ï² Not Applicable ï² CSST ï² Brass ï² Other Proposed Piping Material: ï² Black Steel ï² Galvanized Steel _______________________________________ Proposed Piping Size: ï² Â½â€ ï² â…â€ ï² Â¾â€ ï² 1â€ ï² 1Â½â€ ï² 2†Distance from Meter to furthest Appliance: Total BTU’s of all Appliances: MECHANICAL PERMIT FEES (per unit) Type of Fixture No. of Units Cost per Unit Subtotal Model No. Additional Plan Review fees x $ 75.00 = Air Cond. Unit ≤100Btu/h x $ 15.00 = Air Cond. Unit >100Btu/h x $ 25.00 = Air Cond. Unit >500Btu/h x $ 50.00 = Air Handling Units x $ 15.00 = Base Mechanical Fee 1 x $ 25.00 = $ 25.00 Boiler <100Btu/h >3hp x $ 15.00 = Boiler >1 million Btu/h<50hp x $ 25.00 = REV03.2022 Page 1 of 2 MECHANICAL PERMIT FEES (per unit) Boiler >1.5 million Btu/h<50hp x $ 50.00 = Boiler >100Btu/h 3-15hp x $ 15.00 = Boiler >500Btu/h 15-30hp x $ 25.00 = Commercial Hoods -Type I x $ 25.00 = Commercial Hoods -Type II x $50.00 = Diffusers x $ 15.00 = Dryer Ducting x $ 15.00 = Ductwork (drawings required) x $ 25.00 = Evaporative Coolers x $ 15.00 = Exhaust/Ventilation Fans x $ 15.00 = Fireplace/Insert/Stove x $ 15.00 = Forced Air Heat ≤100 Btu/h x $ 15.00 = Forced Air Heat >100 Btu/h x $ 25.00 = Gas Clothes Dryer x $ 15.00 = Gas Fired AC ≤100 Btu/h x $ 15.00 = Gas Fired AC >100 Btu/h x $ 25.00 = Gas Fired AC > 500 Btu/h x $ 50.00 = Gas Piping ≤ 5 units x $ 15.00 = Gas Piping > 5 units (plus <5 units) x $ 2.00 = Heat Exchangers x $ 15.00 = Heat Pump-Condensing Unit x $ 25.00 = Hot Water Heat Coils x $ 15.00 = Miscellaneous Appliance - regulated by $ 15.00 x = mechanical code, not otherwise specified Pkg. Units ≤100btu x $ 25.00 = Pkg. Units >100btu x $50.00 = Range/Cook top-Gas Fired x $ 15.00 = Refrigeration Unit ≤100Btu/h x $ 15.00 = Refrigeration Unit >100Btu/h x $ 25.00 = Refrigeration. Unit >500Btu/h x $ 50.00 = Re-inspection fee x $ 75.00 = Residential Range Hood x $ 15.00 = Unit Heaters ≤ 100 Btu/h x $ 15.00 = Unit Heaters >100 Btu/h x $ 25.00 = VAV Boxes (Variable Air Volume, part of air $ 10.00 x = conditioning system) Wall Heaters - Gas Fired x $ 25.00 = Water Heater - Gas Fired x $ 25.00 = Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total REV2.2020 Page 2 of 2 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ï² SCHEMATIC IS TO SCALE ï² SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated I hereby certify that I am the Owner, Applicant, Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. A final inspection and approval shall be obtained when complete. Signature Print Name Date REV2.2020 Page 3 of 3 Revision A: • 3. SPECIFICATION has been corrected. OBD946 is void. OUTDOOR UNIT TECHNICAL & HFC No. OBD946 utilized REVISED EDITION-A SERVICE MANUAL R454B Models MUZ-FX06NLHZ - U1 MUZ-FX09NLHZ - U1 MUZ-FX12NLHZ - U1 MUZ-FX15NLHZ - U1 Indoor unit technical & service manual MSZ-FX•NL Series (OBD945) MUZ-FX18NLHZ - U1 Indoor unit service manual MSZ-FX•NL Series (OBH945) MUZ-FX24NLHZ - U1 Outdoor unit service manual MUZ-FX•NLZ/NLHZ Series (OBH946) CONTENTS • SERVICING PRECAUTIONS FOR UNITS USING REFRIGERANT R454B ····················· 3 1. TECHNICAL CHANGES ······························ 8 2. PART NAMES AND FUNCTIONS ·················· 9 3. SPECIFICATION ·······································10 4. OUTLINES AND DIMENSIONS ····················13 5. WIRING DIAGRAM ····································15 6. REFRIGERANT SYSTEM DIAGRAM ············16 7. DATA ·······················································18 8. ACTUATOR CONTROL ······························35 9. SERVICE FUNCTIONS ·······························36 10. TROUBLESHOOTING ································37 MUZ-FX06NLHZ 11. DISASSEMBLY INSTRUCTIONS ··················62 MUZ-FX09NLHZ 12. POSITION OF THE CENTER OF GRAVITY· ····73 13. NOISE CRITERION CURVES ·······················74 MUZ-FX12NLHZ 14. MAX. HEATING CAPACITY IN LOW AMBIENT TEMPERATURE ··············76 15. PERFORMANCE CHART ····························79 16. CAPACITY CORRECTION RATIO CURVE FOR PIPING LENGTH ································91 17. PART LOAD CAPACITY CHART ··················92 Use the specified refrigerant only Never use any refrigerant other than that specified. Doing so may cause a burst, an explosion, or fire when the unit is being used, serviced, or disposed of. Correct refrigerant is specified in the manuals and on the spec labels provided with our products. We will not be held responsible for mechanical failure, system malfunction, unit breakdown or accidents caused by failure to follow the instructions. <Preparation before the repair service> • Prepare the proper tools. • Prepare the proper protectors. • Provide adequate ventilation. • After stopping the operation of the air conditioner, turn off the power-supply breaker and pull the power plug. • Discharge the capacitor before the work involving the electric parts. <Precautions during the repair service> • Do not perform the work involving the electric parts with wet hands. • Do not pour water into the electric parts. • Do not touch the refrigerant. • Do not touch the hot or cold areas in the refrigeration cycle. • When the repair or the inspection of the circuit needs to be done without turning off the power, exercise great caution not to touch the live parts. WARNING • When the refrigerant circuit has a leak, do not execute pump down with the compressor. • When pumping down the refrigerant, stop the compressor before disconnecting the refrigerant pipes. The compressor may burst if air etc. get into it. • When opening or closing the valve below freezing temperatures, refrigerant may spurt out from the gap between the valve stem and the valve body, resulting in injuries. Revision A: • 3. SPECIFICATION has been corrected. OBD946_2 SERVICING PRECAUTIONS FOR UNITS USING REFRIGERANT R454B Servicing precautions for units using refrigerant R454B Refrigerant A2LSafety Group WARNING This unit uses a flammable refrigerant. If refrigerant leaks and comes in contact with fire or heating part, it will create harmful gas and there is risk of fire. Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The appliance should not be stored in a room with continuously operating ignition sources (for example: open flames, an operating gas appliance, or an operating electric heater). Do not pierce or burn. Be aware that refrigerants may not contain an odor. • Maintenance, service and repair operations shall be performed by authorized technician with required qualification. • Servicing shall be performed only by methods recommended by the manufacturer. • Refrigerant piping shall be protected from physical damage. • Field installed piping should be kept to a minimum. • Compliance with national gas regulations shall be observed. • All field joints shall be accessible for inspection prior to being covered or enclosed. WARNING • The mounting height of indoor unit shall be 5.9 ft (1.8 m) or more from the floor. Up to 7.5 ft (2.3 m) is recommended. • The unit shall be installed in rooms exceed the minimum room area (Amin) determined by total refrigerant amount (M). NOTE: For the corresponding table of the branch box system, refer to the multi-unit installation manual. SYSTEM WITHOUT BRANCH BOX M Amin M Amin [kg] [lbs, oz] [m2] [ft2] [kg] [lbs, oz] [m2] [ft2] 0.5 1 1 1.9 21 1.7 3 11 6.3 68 0.6 1 5 2.3 25 1.8 3 15 6.8 74 0.7 1 8 2.6 28 1.9 4 3 7.2 78 0.8 1 12 3.0 33 2.0 4 6 7.6 82 0.9 1 15 3.4 37 2.1 4 10 7.9 86 1.0 2 3 3.8 41 2.2 4 13 8.3 90 1.1 2 6 4.1 45 2.3 5 1 8.7 94 1.2 2 10 4.5 49 2.4 5 4 9.1 98 1.3 2 13 4.9 53 2.5 5 8 9.4 102 1.4 3 1 5.2 56 2.6 5 11 9.8 106 1.5 3 4 5.6 61 2.7 5 15 10.2 110 1.6 3 8 6.0 65 2.8 6 2 10.6 115 1. REFRIGERANT PIPE NITROGEN PRESSURE TEST METHOD (1) Connect the testing tools. • Make sure the stop valves are closed and do not open them. • Add pressure to the refrigerant lines through the service port of the stop valve for GAS. (2) Do not add pressure to the specified pressure all at once; add pressure little by little. 1. Pressurize to 0.5 MPa (73 psig, 5 kgf/cm2G), wait 5 minutes, and make sure the pressure does not decrease. 2. Pressurize to 1.5 MPa (218 psig, 15 kgf/cm2G), wait 5 minutes, and make sure the pressure does not decrease. 3. Pressurize to 4.15 MPa (601 psig, 41.5 kgf/cm2G) and measure the surrounding temperature and refrigerant pressure. (3) If the specified pressure holds for 24 Hours and does not decrease, the pipes have passed the test and there are no leaks. • If the surrounding temperature changes by 1°F (0.5°C), the pressure will change by about 1 psig (0.007 MPa). Make the necessary corrections. (4) If the pressure decreases in steps (2) or (3), there is a gas leak. Look for the source of the gas leak. OBD946_3 2. Additional refrigerant charge Additional refrigerant charge Refrigerant for the indoor units and the extended piping is not included in the outdoor unit when the unit is shipped from the factory. Therefore, charge each refrigerant piping system with additional refrigerant at the installation site. In addition, in order to carry out service, enter the size and length of each liquid pipe and additional refrigerant charge amounts in the spaces pro- vided on the “Refrigerant amount†plate on the outdoor unit. NOTE: • When the unit is stopped, charge the unit with the additional refrigerant through the liquid stop valve after the pipe exten- sions and indoor units have been vacuumized. • When the unit is operating, add refrigerant to the gas check valve using a safety charger. Do not add liquid refrigerant directly to the check valve. Refrigerant adjustment *1 Model MSZ-FX06/09/12NL MSZ-FX15/18/24NL Chargeless pipe length A 25 ft (7.5 m) 50 ft (15 m) Refrigerant adjustment B 0.22 oz/ft (20 g/m) Additional refrigerant Pipe length up to A : No need Pipe length exceeds A : B×(pipe length - A) *1 When installing multi units, refer to the installation manual of the multi outdoor unit for unit installation. 3. REFRIGERANT SENSOR INSTALLATION AND REPLACEMENT • For system with branch box, the refrigerant sensor shall be installed to the indoor unit before turning on the breaker. The refrigerant sensor is located inside the branch box package or can be ordered separately Parts Number MAC-100RS-E . • When the refrigerant sensor is installed in the indoor unit, the system may stop operation if refrigerant leaks are detected. • If the refrigerant sensor fails, replace the refrigerant sensor. • The refrigerant sensor shall only be replaced with manufacturer approved sensor. • If the refrigerant sensor error occurs even if the sensor is installed, check the cable connection for the sensor side and the main board side. (4) (5) Refrigerant sensor (2), (3) (5) Lead wire Fig. 1 Fig. 2 (1) Remove the panel right assembly. (2) Take out the lead wire. (Fig. 1) (3) Connect the lead wire to the refrigerant sensor. (Fig. 1) (4) Push the lead wire into the slit so that the refrigerant sensor does not press it. (5) Install the refrigerant sensor as shown in the figure. (Fig. 2) OBD946_4 4. Cautions for the unit using R454B refrigerant Basic work procedures are the same as those for conventional units using refrigerant R410A. However, pay careful attention to the following points. â– Information on servicing 1. Checks to the area Prior to beginning work on systems containing FLAMMABLE REFRIGERANTS, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the REFRIGERATING SYSTEM, 2 to 6 below shall be completed prior to con- ducting work on the system. 2. Work procedure Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapour being pres- ent while the work is being performed. 3. General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. 4. Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially toxic or flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with all applicable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe. 5. Presence of fire extinguisher If any hot work is to be conducted on the refrigerating equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area. 6. No ignition sources No person carrying out work in relation to a REFRIGERATING SYSTEM which involves exposing any pipe work shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equip- ment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking†signs shall be displayed. 7. Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely dis- perse any released refrigerant and preferably expel it externally into the atmosphere. 8. Checks to the refrigerating equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt, consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using FLAMMABLE REFRIGERANTS: • the actual REFRIGERANT CHARGE is in accordance with the room size within which the refrigerant containing parts are installed; • the ventilation machinery and outlets are operating adequately and are not obstructed; • marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected; • refrigerating pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded. 9. Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solu- tion shall be used. This shall be reported to the owner of the equipment so all parties are advised. Initial safety checks shall include: • that capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking; • that no live electrical components and wiring are exposed while charging, recovering or purging the system; • that there is continuity of earth bonding. OBD946_5 â– Repairs to sealed components Sealed electrical components shall be replaced. â– Repair to intrinsically safe components Intrinsically safe components must be replaced. â– Cabling Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans. â– Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used. The following leak detection methods are deemed acceptable for all refrigerant systems. Electronic leak detectors may be used to detect refrigerant leaks but, in the case of FLAMMABLE REFRIGERANTS, the sen- sitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed, and the appropriate percentage of gas (25 % maximum) is confirmed. Leak detection fluids are also suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak. â– Removal and evacuation When breaking into the refrigerant circuit to make repairs - or for any other purpose -conventional procedures shall be used. However, for flammable refrigerants it is important that best practice be followed, since flammability is a consideration. The following procedure shall be adhered to: • safely remove refrigerant following local and national regulations; • evacuate; • purge the circuit with inert gas; • evacuate; • continuously flush or purge with inert gas when using flame to open circuit; and • open the circuit. The refrigerant charge shall be recovered into the correct recovery cylinders if venting is not allowed by local and national codes. For appliances containing flammable refrigerants, the system shall be purged with oxygen-free nitrogen to render the appli- ance safe for flammable refrigerants. This process might need to be repeated several times. Compressed air or oxygen shall not be used for purging refrigerant systems. For appliances containing flammable refrigerants, refrigerants purging shall be achieved by breaking the vacuum in the sys- tem with oxygen-free nitrogen and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final oxygen-free nitrogen charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. The outlet for the vacuum pump shall not be close to any potential ignition sources, and ventilation shall be available. â– Charging procedures In addition to conventional charging procedures, the following requirements shall be followed. • Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them. • Cylinders shall be kept in an appropriate position according to the instructions. • Ensure that the REFRIGERATING SYSTEM is earthed prior to charging the system with refrigerant. • Label the system when charging is complete (if not already). • Extreme care shall be taken not to overfill the REFRIGERATING SYSTEM. Prior to recharging the system, it shall be pressure-tested with the appropriate purging gas. The system shall be leak-tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site. OBD946_6 â– Decommissioning Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of recovered refrigerant. It is essential that electrical power is available before the task is commenced. • Become familiar with the equipment and its operation. • Isolate system electrically. • Before attempting the procedure, ensure that: - mechanical handling equipment is available, if required, for handling refrigerant cylinders; - all personal protective equipment is available and being used correctly; - the recovery process is supervised at all times by a competent person; - recovery equipment and cylinders conform to the appropriate standards. • Pump down refrigerant system, if possible. • If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system. • Make sure that cylinder is situated on the scales before recovery takes place. • Start the recovery machine and operate in accordance with instructions. • Do not overfill cylinders (no more than 80 % volume liquid charge). • Do not exceed the maximum working pressure of the cylinder, even temporarily. • When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off. • Recovered refrigerant shall not be charged into another REFRIGERATING SYSTEM unless it has been cleaned and checked. â– Labelling Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. For appliances containing FLAMMABLE REFRIGERANTS, ensure that there are labels on the equipment stating the equipment contains FLAMMABLE REFRIGERANT. â– Recovery When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e., special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure-relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of the flammable refrigerant. If in doubt, the manufacturer should be consulted. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. The recovered refrigerant shall be processed according to local legislation in the correct recovery cylinder, and the relevant waste transfer note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that FLAMMABLE REFRIGERANT does not remain within the lubricant. The compressor body shall not be heated by an open flame or other ignition sources to accelerate this process. When oil is drained from a system, it shall be carried out safely. OBD946_7 1 TECHNICAL CHANGES MUZ-FX06NLHZ - U1 MUZ-FX09NLHZ - U1 MUZ-FX12NLHZ - U1 MUZ-FX15NLHZ - U1 MUZ-FX18NLHZ - U1 MUZ-FX24NLHZ - U1 1. New model OBD946_8 2 PART NAMES AND FUNCTIONS MUZ-FX06NLHZ MUZ-FX09NLHZ MUZ-FX12NLHZ Air inlet (Back and side) Piping Air outlet Drain hose Drain outlet MUZ-FX15NLHZ MUZ-FX18NLHZ MUZ-FX24NLHZ Air inlet (Back and side) Piping Air outlet Drain hose Drain outlet OBD946_9 3 SPECIFICATION Outdoor unit model MUZ-FX06NLHZ MUZ-FX09NLHZ MUZ-FX12NLHZ Capacity Cooling *1 Btu/h 6,000 (1,700 – 14,000) 9,000 (2,500 – 15,000) 12,000 (2,500 – 16,100) Rated (Minimum – Maximum) Heating 47 *1 Btu/h 9,000 (1,700 – 20,000) 12,000 (3,100 – 21,300) 13,200 (3,100 – 23,500) Capacity Heating 17 *2 Btu/h 6,000 (14,400) 7,700 (16,300) 9,300 (18,200) Rated (Maximum) Power consumption Cooling *1 W 280 (120 – 1,240) 490 (160 – 1,580) 780 (160 – 1,660) Rated (Minimum – Maximum) Heating 47 *1 W 540 (120 – 1,770) 710 (180 – 2,130) 920 (180 – 2,140) Power consumption Heating 17 *2 W 510 (1,570) 650 (2,000) 800 (2,140) Rated (Maximum) EER2 *1 [SEER2] *3 Cooling 21.45 [35.0] 18.35 [33.1] 15.40 [29.9] HSPF2 Region IV *4 Heating 13.0 13.3 12.4 COP Heating 4.88 4.95 4.20 Cooling % 76 88 94 Power factor Heating % 90 93 95 Power supply V, phase, Hz 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 Max. fuse size (time delay) A 15 15 15 Min. circuit ampacity A 12 14 14 Fan motor A 0.76 0.76 0.76 Model SRB092FQFMT SRB140FQHMT SRB140FQHMT R.L.A A 6.6 7.8 7.8 Compressor L.R.A A 8.2 9.8 9.8 fl oz. (L) Refrigeration oil 11.8 (0.35)/(RM68EH) 11.8 (0.35)/(RM68EH) 11.8 (0.35)/(RM68EH) (Model) Refrigerant control Linear expansion valve Linear expansion valve Linear expansion valve Cooling dB(A) 47 49 49 Sound level *1 Heating dB(A) 48 49 51 Airflow Cooling CFM 1,815 – 1,225 – 678 1,815 – 1,303 – 678 1,815 – 1,303 – 678 High – Med. – Low Heating CFM 1,321 – 1,225 – 678 1,321 – 1,321 – 678 1,321 – 1,321 – 678 Fan speed Cooling rpm 1,060 – 740 – 450 1,060 – 780 – 450 1,060 – 780 – 450 High – Med. – Low Heating rpm 790 – 740 – 450 790 – 790 – 450 790 – 790 – 450 Defrost method Reverse cycle Reverse cycle Reverse cycle W in. 31-1/2 31-1/2 31-1/2 Dimensions D in. 11-1/4 11-1/4 11-1/4 H in. 28-1/8 28-1/8 28-1/8 Weight lb. 85 89 89 External finish Munsell 3Y 7.8/1.1 Munsell 3Y 7.8/1.1 Munsell 3Y 7.8/1.1 Control voltage (by built-in transformer) V DC 12 – 24 12 – 24 12 – 24 Refrigerant piping Not supplied Not supplied Not supplied Refrigerant pipe size Liquid in. 1/4 1/4 1/4 (Min. wall thickness) Gas in. 3/8 3/8 3/8 Indoor Flared Flared Flared Connection method Outdoor Flared Flared Flared Height Between the indoor & ft. 40 40 40 difference outdoor units Piping length ft. 65 65 65 Refrigerant charge (R454B) 2 lbs. 10 oz 2 lbs. 12 oz 2 lbs. 12 oz NOTE: Test conditions are based on AHRI 210/240. *1: Rating conditions (Cooling) — Indoor: 80ËšFDB, 67ËšFWB, Outdoor: 95ËšFDB, (75ËšFWB) (Heating) — Indoor: 70ËšFDB, 60ËšFWB, Outdoor: 47ËšFDB, 43ËšFWB *2: Rating conditions (Heating) — Indoor: 70ËšFDB, 60ËšFWB, Outdoor: 17ËšFDB, 15ËšFWB *3: Test condition (Refer to page 12.) *4: Test condition (Refer to page 12.) OBD946_10 Outdoor unit model MUZ-FX15NLHZ MUZ-FX18NLHZ MUZ-FX24NLHZ Capacity Cooling *1 Btu/h 15,000 (3,700 – 19,100) 17,200 (3,700 – 21,500) 20,800 (2,500 – 26,500) Rated (Minimum – Maximum) Heating 47 *1 Btu/h 16,500 (5,150 – 28,400) 17,000 (5,150 – 30,200) 19,800 (5,500 – 36,200) Capacity Heating 17 *2 Btu/h 10,600 (26,500) 12,700 (28,200) 13,600 (29,200) Rated (Maximum) Power consumption Cooling *1 W 1,020 (260 – 2,200) 1,320 (260 – 2,360) 1,560 (260 – 3,370) Rated (Minimum – Maximum) Heating 47 *1 W 1,080 (280 – 2,630) 1,390 (280 – 2,890) 1,500 (320 – 3,590) Power consumption Heating 17 *2 W 1,010 (3,700) 1,240 (3,830) 1,320 (3,800) Rated (Maximum) EER2 *1 [SEER2] *3 Cooling 14.70 [25.9] 13.05 [25.5] 13.35 [23.5] HSPF2 Region IV *4 Heating 11.0 11.1 10.5 COP Heating 4.47 3.58 3.86 Cooling % 100 97 98 Power factor Heating % 97 99 100 Power supply V, phase, Hz 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 Max. fuse size (time delay) A 20 20 20 Min. circuit ampacity A 23 23 22 Fan motor A 0.76 0.76 0.76 Model SRB172FQHMT SRB172FQHMT SRB220FQYMT R.L.A A 13.6 13.6 13.1 Compressor L.R.A A 17 17 16.4 fl oz. (L) Refrigeration oil 14.5 (0.43)/(RM68EH) 14.5 (0.43)/(RM68EH) 15.6 (0.46)/(RM68EH) (Model) Refrigerant control Linear expansion valve Linear expansion valve Linear expansion valve Cooling dB(A) 51 52 55 Sound level *1 Heating dB(A) 55 55 55 Airflow Cooling CFM 2,204 – 1,773 – 978 2,204 – 1,773 – 978 2,204 – 2,204 – 1,391 High – Med. – Low Heating CFM 2,440 – 1,935 – 978 2,440 – 1,935 – 978 2,440 – 1,935 – 978 Fan speed Cooling rpm 900 – 740 – 450 900 – 740 – 450 900 – 900 – 600 High – Med. – Low Heating rpm 990 – 800 – 450 990 – 800 – 450 990 – 800 – 450 Defrost method Reverse cycle Reverse cycle Reverse cycle W in. 33-1/16 33-1/16 33-1/16 Dimensions D in. 13 13 13 H in. 34-5/8 34-5/8 34-5/8 Weight lb. 119 119 122 External finish Munsell 3Y 7.8/1.1 Munsell 3Y 7.8/1.1 Munsell 3Y 7.8/1.1 Control voltage (by built-in transformer) V DC 12 – 24 12 – 24 12 – 24 Refrigerant piping Not supplied Not supplied Not supplied Refrigerant pipe size Liquid in. 1/4 1/4 1/4 (Min. wall thickness) Gas in. 1/2 1/2 5/8 Indoor Flared Flared Flared Connection method Outdoor Flared Flared Flared Height Between the indoor & ft. 50 50 50 difference outdoor units Piping length ft. 100 100 100 Refrigerant charge (R454B) 3 lbs. 7 oz 3 lbs. 7 oz 3 lbs. 6 oz NOTE: Test conditions are based on AHRI 210/240. *1: Rating conditions (Cooling) — Indoor: 80ËšFDB, 67ËšFWB, Outdoor: 95ËšFDB, (75ËšFWB) (Heating) — Indoor: 70ËšFDB, 60ËšFWB, Outdoor: 47ËšFDB, 43ËšFWB *2: Rating conditions (Heating) — Indoor: 70ËšFDB, 60ËšFWB, Outdoor: 17ËšFDB, 15ËšFWB *3: Test condition (Refer to page 12.) *4: Test condition (Refer to page 12.) OBD946_11 Test condition *3, *4 AHRI Indoor air condition (°F) Outdoor air condition (°F) Mode Test 210/240 Dry bulb Wet bulb Dry bulb Wet bulb “A-Full†Cooling Steady State 80 67 95 75 at rated compressor speed “B-Full†Cooling Steady State 80 67 82 65 at rated compressor speed SEER “B-Low†Cooling Steady State 80 67 82 65 (Cooling) at minimum compressor speed “F-Low†Cooling Steady State 80 67 67 53.5 at minimum compressor speed “E-Int†Cooling Steady State 80 67 87 69 at intermediate compressor speed *5 “H1-Nom†Heating Steady State 70 60 47 43 at rated compressor speed “H3-Full†Heating 70 60 17 15 at rated compressor speed HSPF “H0-Low†Heating Steady State 70 60 62 56.5 (Heating) at minimum compressor speed “H1-Low†Heating Steady State 70 60 47 43 at minimum compressor speed “H2-Int†Heating 70 60 35 33 at intermediate compressor speed *5 *5: At intermediate compressor speed = (“Rated compressor speed†- “minimum compressor speedâ€) / 3 + “minimum compressor speedâ€. OPERATING RANGE (1) POWER SUPPLY Rated voltage Guaranteed voltage (V) 208/230 V Min. 187 208 230 Max. 253 Outdoor unit 1 phase 60 Hz (2) OPERATION Intake air temperature (°F) Mode Condition Outdoor DB WB Standard temperature 95 — Maximum temperature 115 — Cooling Minimum temperature 14 — Maximum humidity — Standard temperature 47 43 Heating Maximum temperature 75 65 Minimum temperature - 22 - 23.8 OBD946_12 4 OUTLINES AND DIMENSIONS MUZ-FX06NLHZ Unit: inch MUZ-FX09NLHZ MUZ-FX12NLHZ REFRIGERANT LIQUID REFRIGERANT PIPE FLARED 1/4ʺ PIPE JOINT GAS REFRIGERANT PIPE FLARED 3/8ʺ OBD946_13 MUZ-FX15NLHZ Unit: inch MUZ-FX18NLHZ MUZ-FX24NLHZ OBD946_14 5 WIRING DIAGRAM MUZ-FX06NLHZ MUZ-FX09NLHZ MUZ-FX12NLHZ MUZ-FX15NLHZ MUZ-FX18NLHZ MUZ-FX24NLHZ OBD946_15 6 REFRIGERANT SYSTEM DIAGRAM MUZ-FX06NLHZ Unit: Inch (mm) MUZ-FX09NLHZ MUZ-FX12NLHZ Refrigerant pipe 3/8 (ø9.52) 4-way valve (with heat insulator) Muffler Outdoor heat Stop valve exchanger Muffler Defrost temperature Discharge Capillary tube thermistor Outdoor thermistor Flared connection RT61 heat temperature O.D. 0.118 × RT68 I.D. 0.079 × 8-9/32 exchanger Muffler thermistor RT62 (ø3.0 × ø2.0 × 210) Service port Ambient Service port (high pressure) temperature (low pressure) thermistor RT65 Compressor Flared connection LEV Strainer Strainer R.V. coil Muffler #100 #100 heating ON cooling OFF Stop valve Capillary tube O.D. 0.157 × Refrigerant pipe 1/4 (ø6.35) I.D. 0.094 × 9-7/16 Refrigerant flow in cooling (with heat insulator) (ø4.0 × ø2.4 × 240) Refrigerant flow in heating MUZ-FX15NLHZ MUZ-FX18NLHZ MUZ-FX24NLHZ Service port (high pressure) Refrigerant pipe 1/2 (ø12.7) (FX15/18) 5/8 (ø15.88) (FX24) 4-way valve Muffler (with heat insulator) Muffler (FX15/18) Outdoor heat exchanger Stop valve Defrost temperature thermistor Outdoor Flared connection Discharge Capillary tube RT61 heat thermistor temperature RT68 Service port O.D. 0.118 × exchanger thermistor (low pressure) I.D. 0.079 × 9-7/16 RT62 (ø3.0 × ø2.0 × 240) Ambient (FX15/18) temperature I.D. 0.094 × 3-15/16 Muffler (ø4.0×ø2.4×100) thermistor RT65 (FX24) Compressor Flared connection LEV Strainer Strainer #100 Muffler #100 R.V. coil heating ON cooling OFF Stop valve Capillary tube O.D. 0.157 × Refrigerant pipe 1/4 (ø6.35) I.D. 0.094 × 3-15/16 Refrigerant flow in cooling (with heat insulator) (ø4.0×ø2.4×100) Refrigerant flow in heating OBD946_16 MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE Refrigerant piping: ft. Piping size O.D: in. Model Max. Length Max. Height difference Gas Liquid A B MUZ-FX06NLHZ MUZ-FX09NLHZ 65 40 3/8 1/4 MUZ-FX12NLHZ MUZ-FX15NLHZ 100 50 1/2 1/4 MUZ-FX18NLHZ MUZ-FX24NLHZ 100 50 5/8 1/4 Indoor unit Max. Height difference B Max. Length A Outdoor unit ADDITIONAL REFRIGERANT CHARGE (R454B: oz.) NOTE: Refrigerant piping exceeding 25 ft. requires additional refrigerant charge according to the calculation. Outdoor unit Refrigerant piping length (one way): ft. Model precharged 25 30 40 50 60 65 MUZ-FX06NLHZ 2 lbs. 10 oz MUZ-FX09NLHZ 0 1.1 3.3 5.5 7.7 8.8 2 lbs. 12 oz MUZ-FX12NLHZ Calculation: X oz. = 0.22 oz./ft. × (Refrigerant piping length (ft.) - 25) NOTE: Refrigerant piping exceeding 50 ft. requires additional refrigerant charge according to the calculation. Outdoor unit Refrigerant piping length (one way): ft. Model precharged 25 30 40 50 60 65 70 80 90 100 MUZ-FX15NLHZ 3 lbs. 7 oz MUZ-FX18NLHZ 0 0 0 0 2.2 3.3 4.4 6.6 8.8 11 MUZ-FX24NLHZ 3 lbs. 6 oz Calculation: X oz. = 0.22 oz./ft. × (Refrigerant piping length (ft.) - 50) OBD946_17 7 DATA MUZ-FX06NLHZ MUZ-FX09NLHZ MUZ-FX12NLHZ MUZ-FX15NLHZ MUZ-FX18NLHZ MUZ-FX24NLHZ 7-1. PERFORMANCE DATA 1) COOLING CAPACITY Indoor air Outdoor intake air DB temperature (ËšF) Model 75 85 95 IWB (ËšF) TC SHC SHF TPC TC SHC SHF TPC TC SHC SHF TPC 71 7.4 6.4 0.87 0.25 6.9 6.0 0.87 0.27 6.5 5.6 0.87 0.29 MUZ-FX06NLHZ 67 7.0 7.0 1.00 0.24 6.5 6.5 1.00 0.26 6.0 6.0 1.00 0.28 63 6.5 6.5 1.00 0.22 6.1 6.1 1.00 0.25 5.6 5.6 1.00 0.27 71 11.0 9.6 0.87 0.44 10.3 8.9 0.87 0.48 9.7 8.4 0.87 0.51 MUZ-FX09NLHZ 67 10.4 10.4 1.00 0.41 9.7 9.7 1.00 0.45 9.0 9.0 1.00 0.49 63 9.8 9.8 1.00 0.39 9.1 9.1 1.00 0.43 8.5 8.5 1.00 0.47 71 14.7 11.0 0.75 0.69 13.7 10.3 0.75 0.76 12.9 9.6 0.75 0.82 MUZ-FX12NLHZ 67 13.9 12.2 0.88 0.66 13.0 11.4 0.88 0.72 12.0 10.6 0.88 0.78 63 13.1 13.1 1.00 0.62 12.1 12.1 1.00 0.69 11.3 11.3 1.00 0.74 71 18.4 12.4 0.68 0.91 17.2 11.6 0.68 0.99 16.1 10.9 0.68 1.07 MUZ-FX15NLHZ 67 17.4 14.1 0.81 0.86 16.2 13.1 0.81 0.94 15.0 12.2 0.81 1.02 63 16.4 15.4 0.94 0.82 15.2 14.3 0.94 0.90 14.1 13.3 0.94 0.97 71 21.1 13.2 0.63 1.17 19.7 12.3 0.63 1.29 18.5 11.6 0.63 1.39 MUZ-FX18NLHZ 67 20.0 15.2 0.76 1.11 18.6 14.1 0.76 1.22 17.2 13.1 0.76 1.32 63 18.7 16.7 0.89 1.06 17.4 15.5 0.89 1.17 16.2 14.4 0.89 1.26 71 25.5 16.5 0.65 1.39 23.8 15.4 0.65 1.52 22.4 14.5 0.65 1.64 MUZ-FX24NLHZ 67 24.1 18.8 0.78 1.31 22.5 17.5 0.78 1.44 20.8 16.2 0.78 1.56 63 22.7 20.7 0.91 1.25 21.0 19.2 0.91 1.38 19.6 17.9 0.91 1.49 OBD946_18 Indoor air Outdoor intake air DB temperature (ËšF) Model 105 115 IWB (ËšF) TC SHC SHF TPC TC SHC SHF TPC 71 6.0 5.2 0.87 0.31 5.5 4.8 0.87 0.32 MUZ-FX06NLHZ 67 5.6 5.6 1.00 0.30 5.1 5.1 1.00 0.31 63 5.1 5.1 1.00 0.29 4.7 4.7 1.00 0.30 71 9.0 7.8 0.87 0.54 8.3 7.2 0.87 0.56 MUZ-FX09NLHZ 67 8.4 8.4 1.00 0.52 7.7 7.7 1.00 0.54 63 7.7 7.7 1.00 0.50 7.0 7.0 1.00 0.52 71 12.0 9.0 0.75 0.86 11.0 8.2 0.75 0.90 MUZ-FX12NLHZ 67 11.2 9.8 0.88 0.83 10.3 9.0 0.88 0.87 63 10.3 10.3 1.00 0.80 9.4 9.4 1.00 0.83 71 15.0 10.2 0.68 1.13 13.8 9.3 0.68 1.17 MUZ-FX15NLHZ 67 14.0 11.3 0.81 1.08 12.8 10.4 0.81 1.13 63 12.8 12.1 0.94 1.04 11.7 11.0 0.94 1.08 71 17.2 10.8 0.63 1.46 15.8 9.9 0.63 1.52 MUZ-FX18NLHZ 67 16.0 12.2 0.76 1.40 14.7 11.2 0.76 1.47 63 14.7 13.1 0.89 1.35 13.4 12.0 0.89 1.40 71 20.8 13.5 0.65 1.72 19.1 12.4 0.65 1.79 MUZ-FX24NLHZ 67 19.3 15.1 0.78 1.65 17.8 13.9 0.78 1.73 63 17.8 16.2 0.91 1.59 16.2 14.8 0.91 1.65 NOTE: 1. IWB : Intake air wet-bulb temperature TC : Total Capacity (×103 Btu/h) SHC : Sensible Heat Capacity (×103 Btu/h) SHF : Sensible Heat Factor TPC : Total Power Consumption (kW) 2. SHC is based on 80ËšF of indoor Intake air DB temperature. 3. Data shown are estimated value. Performance may vary depending on operating conditions. 2) COOLING CAPACITY CORRECTIONS Refrigerant piping length (one way: ft.) 25 (std.) 40 65 100 MUZ-FX06NLHZ 0.997 0.992 — MUZ-FX09NLHZ 0.993 0.981 — MUZ-FX12NLHZ 0.987 0.967 — 1.0 MUZ-FX15NLHZ 0.996 0.988 0.978 MUZ-FX18NLHZ 0.994 0.983 0.969 MUZ-FX24NLHZ 0.996 0.99 0.982 OBD946_19 3) HEATING CAPACITY CORRECTIONS Refrigerant piping length (one way: ft.) 25 (std.) 40 65 100 MUZ-FX06NLHZ MUZ-FX09NLHZ 1.0 0.997 0.993 — MUZ-FX12NLHZ MUZ-FX15NLHZ MUZ-FX18NLHZ 1.0 0.997 0.993 0.987 MUZ-FX24NLHZ 4) HEATING CAPACITY Indoor air Outdoor intake air WB temperature (ËšF) Model 5 15 25 35 43 45 55 IDB (ËšF) TC TPC TC TPC TC TPC TC TPC TC TPC TC TPC TC TPC 75 4.0 0.32 5.2 0.40 6.5 0.47 7.8 0.53 8.8 0.55 9.0 0.56 10.3 0.58 MUZ-FX06NLHZ 70 4.3 0.31 5.5 0.39 6.8 0.46 8.0 0.51 9.0 0.54 9.3 0.55 10.5 0.57 65 4.5 0.29 5.7 0.37 7.1 0.45 8.2 0.50 9.3 0.53 9.5 0.53 10.7 0.56 75 5.3 0.42 7.0 0.53 8.7 0.62 10.4 0.69 11.7 0.73 12.1 0.74 13.7 0.77 MUZ-FX09NLHZ 70 5.7 0.40 7.4 0.51 9.0 0.61 10.6 0.67 12.0 0.71 12.4 0.72 14.0 0.75 65 6.0 0.38 7.6 0.49 9.4 0.59 11.0 0.66 12.4 0.69 12.7 0.70 14.3 0.74 75 5.8 0.54 7.7 0.69 9.6 0.81 11.4 0.90 12.9 0.94 13.3 0.96 15.0 0.99 MUZ-FX12NLHZ 70 6.3 0.52 8.1 0.66 9.9 0.79 11.7 0.87 13.2 0.92 13.6 0.94 15.4 0.98 65 6.6 0.50 8.3 0.63 10.4 0.76 12.1 0.85 13.6 0.90 14.0 0.91 15.7 0.96 75 7.3 0.64 9.6 0.80 12.0 0.95 14.3 1.05 16.1 1.11 16.6 1.12 18.8 1.17 MUZ-FX15NLHZ 70 7.8 0.61 10.1 0.78 12.4 0.92 14.6 1.03 16.5 1.08 17.0 1.10 19.2 1.14 65 8.3 0.58 10.4 0.75 13.0 0.89 15.1 1.00 17.0 1.05 17.5 1.07 19.6 1.12 75 7.5 0.82 9.9 1.04 12.3 1.22 14.7 1.36 16.6 1.42 17.1 1.45 19.4 1.50 MUZ-FX18NLHZ 70 8.1 0.79 10.5 1.00 12.8 1.19 15.0 1.32 17.0 1.39 17.5 1.42 19.8 1.47 65 8.5 0.75 10.7 0.96 13.3 1.15 15.6 1.29 17.5 1.36 18.0 1.38 20.2 1.45 75 8.7 0.89 11.5 1.12 14.4 1.31 17.1 1.46 19.3 1.54 19.9 1.56 22.6 1.62 MUZ-FX24NLHZ 70 9.4 0.85 12.2 1.08 14.9 1.28 17.5 1.43 19.8 1.50 20.4 1.53 23.1 1.59 65 9.9 0.81 12.5 1.04 15.5 1.24 18.1 1.39 20.4 1.46 21.0 1.49 23.6 1.56 NOTE: 1. IDB : Intake air dry-bulb temperature TC : Total Capacity (x103 Btu/h) TPC : Total Power Consumption (kW) 2. Above data is for heating operation without any frost. 3. Data shown are estimated value. Performance may vary depending on operating conditions. How to operate with fixed operational frequency of the compressor. 1. Press the emergency operation switch on the front of the indoor unit, and select either EMERGENCY COOL mode or EMERGENCY HEAT mode before starting to operate the air conditioner. 2. The compressor starts with operational frequency. 3. The fan speed of the indoor unit is High. 4. This operation continues for 30 minutes. 5. In order to release this operation, press the emergency operation switch twice or once, or press any button on the remote controller. OBD946_20 7-2. PERFORMANCE CURVE Cooling (at Rated frequency) Cooling capacity (at Rated frequency) 1.5 Indoor intake air Wet-bulb 1.4 temperature( F) 1.3 1.2 79 1.1 75 difference (°F) 1.0 Capacity correction factors 72 0.9 68 Indoor air Wet-bulb temperature 64 14 23 32 41 50 59 68 77 86 95 104 113 Outdoor intake air DB temperature(°F) MUZ-FX06NLHZ MUZ-FX09NLHZ SHF at rating condition = 1.00 SHF at rating condition = 1.00 Airflow = 425 CFM Airflow = 535 CFM 0.35 0.6 71 67 71 67 0.5 63 0.30 63 0.4 (kW) (kW) 0.25 Indoor intake air WB temperature (°F) 0.3 Indoor intake air WB temperature (°F) 0.20 0.2 Total power consumption 65 75 85 95 105 115 Total power consumption 65 75 85 95 105 115 Outdoor intake air DB temperature (°F) Outdoor intake air DB temperature (°F) MUZ-FX12NLHZ MUZ-FX15NLHZ SHF at rating condition = 0.88 SHF at rating condition = 0.81 Airflow = 535 CFM Airflow = 590 CFM 1.0 1.7 71 67 1.4 0.8 63 71 1.1 67 0.6 63 (kW) (kW)0.8 0.4 Indoor intake air WB temperature (°F) Indoor intake air WB temperature (°F) 0.5 0.2 0.2 Total power consumption 65 75 85 95 105 115 Total power consumption 65 75 85 95 105 115 Outdoor intake air DB temperature (°F) Outdoor intake air DB temperature (°F) MUZ-FX18NLHZ MUZ-FX24NLHZ SHF at rating condition = 0.76 SHF at rating condition = 0.78 Airflow = 590 CFM Airflow = 720 CFM 1.7 71 2.2 67 71 63 1.7 67 1.2 63 1.2 (kW) (kW) 0.7 Indoor intake air WB temperature (°F) 0.7 Indoor intake air WB temperature (°F) 0.2 0.2 Total power consumption 65 75 85 95 105 115 Total power consumption 65 75 85 95 105 115 Outdoor intake air DB temperature (°F) Outdoor intake air DB temperature (°F) This value of frequency is not the same as the actual frequency in operating. Refer to 7-5 and 7-6 for the relationships between frequency and capacity. NOTE: Data shown are estimated value. Performance may vary depending on operating conditions. OBD946_21 Heating (at Rated frequency) Heating capacity (at Rated frequency) 1.3 59 68 1.2 79 1.1 1.0 0.9 0.8 0.7 Indoor intake air Dry-bulb temperature ( F) difference (°F) 0.6 0.5 Indoor air Dry-bulb temperatureCapacity correction factor 0.4 -4 5 14 23 32 41 50 59 Outdoor intake air WB temperature (°F) MUZ-FX06NLHZ MUZ-FX09NLHZ Airflow= 485 CFM Airflow= 485 CFM 0.7 0.8 75 70 75 65 0.6 70 65 0.6 0.5 (kW)0.4 (kW) 0.3 Indoor intake air DB temperature (°F) 0.2 Indoor intake air DB temperature (°F) Total power consumption 0.1 Total power consumption 0.1 -10 -5 5 15 25 35 45 55 65 -10 -0.5 5 15 25 35 45 55 65 Outdoor intake air WB temperature (°F) Outdoor intake air WB temperature (°F) MUZ-FX12NLHZ MUZ-FX15NLHZ Airflow= 485 CFM Airflow= 615 CFM 1.2 1.7 75 1.0 70 75 65 1.2 70 0.8 65 (kW)0.5 (kW) 0.7 0.3 Indoor intake air DB temperature (°F) Indoor intake air DB temperature (°F) Total power consumption 0.1 Total power consumption 0.2 -5 5 15 25 35 45 55 65 -10 -5 5 15 25 35 45 55 65 Outdoor intake air WB temperature (°F) Outdoor intake air WB temperature (°F) MUZ-FX18NLHZ MUZ-FX24NLHZ Airflow= 615 CFM Airflow= 745 CFM 1.7 1.7 75 75 70 70 65 65 1.2 1.2 (kW) Indoor intake air DB temperature (°F) (kW) 0.7 Indoor intake air DB temperature (°F) 0.7 Total power consumption 0.2 Total power consumption 0.2 -5 5 15 25 35 45 55 65 -5 5 15 25 35 45 55 65 Outdoor intake air WB temperature (°F) Outdoor intake air WB temperature (°F) This value of frequency is not the same as the actual frequency in operating. Refer to 7-5 and 7-6 for the relationships between frequency and capacity. NOTE: Data shown are estimated value. Performance may vary depending on operating conditions. OBD946_22 7-3. CONDENSING PRESSURE Cooling Data are based on the condition of indoor humidity 50 %. Air flow should be set to High speed. MUZ-FX06NLHZ (psig) 440 86 (psig) 80 240 75 400 70 Indoor DB temperature (°F) 220 86 360 200 80 75 180 320 70 160 280 Condensing pressure Suction pressure140 240 Indoor DB temperature (°F) 120 200 100 65 70 75 80 85 90 95 100 105 110 115 (°F) 65 70 75 80 85 90 95 100 105 110 115 (°F) Outdoor ambient temperature Outdoor ambient temperature MUZ-FX09NLHZ (psig) 480 (psig) 86 200 440 80 75 70 400 86 Indoor DB temperature (°F) 180 360 80 320 75 160 Condensing pressure280 Suction pressure 70 240 Indoor DB temperature (°F) 200 140 65 70 75 80 85 90 95 100 105 110 115 (°F) 65 70 75 80 85 90 95 100 105 110 115 (°F) Outdoor ambient temperature Outdoor ambient temperature MUZ-FX12NLHZ (psig) 600 (psig) 220 550 200 500 86 80 75 70 180 450 86 400 160 80 75 Indoor DB temperature (°F) 350 140 70 Condensing pressure300 Suction pressure120 Indoor DB temperature (°F) 250 100 200 80 65 70 75 80 85 90 95 100 105 110 115 (°F) 65 70 75 80 85 90 95 100 105 110 115 (°F) Outdoor ambient temperature Outdoor ambient temperature OBD946_23 MUZ-FX15NLHZ (psig) 500 (psig) 200 450 86 80 75 180 70 400 160 Indoor DB temperature (°F) 86 350 80 140 Indoor DB temperature (°F) 75 70 300 120 Condensing pressure Suction pressure 250 100 200 80 65 70 75 80 85 90 95 100 105 110 115 (°F) 65 70 75 80 85 90 95 100 105 110 115 (°F) Outdoor ambient temperature Outdoor ambient temperature MUZ-FX18NLHZ (psig) 500 (psig) 200 86 450 80 75 70 180 400 160 Indoor DB temperature (°F) 350 86 Indoor DB temperature (°F) 140 80 300 120 75 Condensing pressure Suction pressure 70 250 100 200 80 65 70 75 80 85 90 95 100 105 110 115 (°F) 65 70 75 80 85 90 95 100 105 110 115 (°F) Outdoor ambient temperature Outdoor ambient temperature MUZ-FX24NLHZ (psig) 500 (psig) 86 200 80 450 75 70 180 400 160 Indoor DB temperature (°F) 86 350 Indoor DB temperature (°F) 140 80 75 300 Suction pressure120 70 Condensing pressure 250 100 200 80 65 70 75 80 85 90 95 100 105 110 115 (°F) 65 70 75 80 85 90 95 100 105 110 115 (°F) Outdoor ambient temperature Outdoor ambient temperature NOTE: Data shown are estimated value. Performance may vary depending on operating conditions. OBD946_24 Heating Data are based on the condition of outdoor humidity 75%. Air flow should be set to High speed. Data are for heating operation without any frost. MUZ-FX06NLHZ (psig) 360 (psig) 200 75 75 70 70 65 320 160 65 280 120 Condensing pressure Suction pressure Indoor DB temperature (°F) 240 80 Indoor DB temperature (°F) 200 40 -5 5 15 25 35 45 55 65 75 (°F) -5 5 15 25 35 45 55 65 75 (°F) Outdoor ambient temperature Outdoor ambient temperature MUZ-FX09NLHZ (psig) 400 (psig) 200 75 75 360 70 70 65 160 65 320 120 280 Condensing pressure Suction pressure Indoor DB temperature (°F) 80 240 Indoor DB temperature (°F) 200 40 -5 5 15 25 35 45 55 65 75 (°F) -5 5 15 25 35 45 55 65 75 (°F) Outdoor ambient temperature Outdoor ambient temperature MUZ-FX12NLHZ (psig) 450 (psig) 200 75 400 75 70 65 70 160 350 Indoor DB temperature (°F) 65 120 300 Condensing pressure Suction pressure Indoor DB temperature (°F) 80 250 200 40 -5 5 15 25 35 45 55 65 75 (°F) -5 5 15 25 35 45 55 65 75 (°F) Outdoor ambient temperature Outdoor ambient temperature OBD946_25 MUZ-FX15NLHZ (psig) 490 (psig) 200 75 450 70 65 160 410 75 370 Indoor DB temperature (°F) 70 65 120 Indoor DB temperature (°F) 330 Condensing pressure Suction pressure 80 290 250 40 -5 5 15 25 35 45 55 65 75 (°F) -5 5 15 25 35 45 55 65 75 (°F) Outdoor ambient temperature Outdoor ambient temperature MUZ-FX18NLHZ (psig) 490 (psig) 200 450 75 70 75 65 410 Indoor DB temperature (°F) 70 160 65 370 120 330 Indoor DB temperature (°F) Condensing pressure Suction pressure 80 290 250 40 -5 5 15 25 35 45 55 65 75 (°F) -5 5 15 25 35 45 55 65 75 (°F) Outdoor ambient temperature Outdoor ambient temperature MUZ-FX24NLHZ (psig) 480 (psig) 200 440 75 70 75 70 65 65 400 160 360 Indoor DB temperature (°F) 120 320 Indoor DB temperature (°F) Condensing pressure280 Suction pressure 80 240 200 40 -5 5 15 25 35 45 55 65 75 (°F) -5 5 15 25 35 45 55 65 75 (°F) Outdoor ambient temperature Outdoor ambient temperature NOTE: 1. Press the emergency operation switch on the front of the indoor unit, and select either EMERGENCY COOL mode or EMERGENCY HEAT mode before starting to operate the air conditioner. 2. The compressor starts with operational frequency. 3. The fan speed of the indoor unit is High. 4. This operation continues for 30 minutes. 5. In order to release this operation, press the emergency operation switch twice or once, or press any button on the remote controller. 6. Data shown are estimated value. Performance may vary depending on operating conditions. OBD946_26 7-4. STANDARD OPERATION DATA Model MSZ-FX06NL Item Unit COOL HEAT Capacity Btu/h 6,000 9,000 SHF — 1.00 — TotalInput kW 0.28 0.54 Rated frequency Hz 28 53 Indoor unit MSZ-FX06NL Power supply V, phase, Hz 208/230, 1 , 60 Input kW 0.014 0.019 Fan motor current A 0.17/0.15 0.21/0.19 Outdoor unit MUZ-FX06NLHZ Power supply V, phase, Hz 208/230, 1, 60 Electrical circuitInput kW 0.266 0.521 Comp. current A 1.41/1.25 2.47/2.21 Fan motor current A 0.22/0.20 0.22/0.20 Condensing pressure psig 314 284 Suction pressure psig 170 106 Discharge temperature °F 135 135 Condensing temperature °F 103 39 Suction temperature °F 71 39 Comp. shell bottom temperature °F — Refrigerant circuitRef. pipe length ft. 25 Refrigerant charge (R454B) 2 lbs. 10 oz DB °F 80 70 Intake air temperature WB °F 67 60 DB °F 66 91 Discharge air temperature WB °F 65 — Indoor unitFan speed (High) rpm 820 900 Airflow (High) CFM 357 (wet) 477 DB °F 95 47 Intake air temperature WB °F — 43 Fan speed rpm 740 Outdoor unitAirflow CFM 1,225 OBD946_27 Model MSZ-FX09NL Item Unit COOL HEAT Capacity Btu/h 9,000 12,000 SHF — 1.00 — TotalInput kW 0.49 0.71 Rated frequency Hz 29.5 45 Indoor unit MSZ-FX09NL Power supply V, phase, Hz 208/230, 1, 60 Input kW 0.024 0.019 Fan motor current A 0.27/0.24 0.21/0.19 Outdoor unit MUZ-FX09NLHZ Power supply V, phase, Hz 208/230, 1, 60 Electrical circuitInput kW 0.466 0.691 Comp. current A 2.18/1.94 3.14/2.88 Fan motor current A 0.25/0.22 0.25/0.23 Condensing pressure psig 329 301 Suction pressure psig 155 103 Discharge temperature °F 140 137 Condensing temperature °F 106 37 Suction temperature °F 60 37 Comp. shell bottom temperature °F — Refrigerant circuitRef. pipe length ft. 25 Refrigerant charge (R454B) 2 lbs.12 oz DB °F 80 70 Intake air temperature WB °F 67 60 DB °F 64 96 Discharge air temperature WB °F 63 — Indoor unitFan speed (High) rpm 970 900 Airflow (High) CFM 447 (wet) 477 DB °F 95 47 Intake air temperature WB °F — 43 Fan speed rpm 780 790 Outdoor unitAirflow CFM 1,303 1,321 OBD946_28 Model MSZ-FX12NL Item Unit COOL HEAT Capacity Btu/h 12,000 13,200 SHF — 0.88 — TotalInput kW 0.78 0.92 Rated frequency Hz 44.5 54.5 Indoor unit MSZ-FX12NL Power supply V, phase, Hz 208/230, 1, 60 Input kW 0.024 0.019 Fan motor current A 0.27/0.24 0.21/0.19 Outdoor unit MUZ-FX12NLHZ Power supply V, phase, Hz 208/230, 1, 60 Electrical circuitInput kW 0.76 0.901 Comp. current A 3.48/3.14 4.14/3.78 Fan motor current A 0.25/0.22 0.25/0.23 Condensing pressure psig 349 324 Suction pressure psig 135 101 Discharge temperature °F 153 146 Condensing temperature °F 111 37 Suction temperature °F 52 36 Comp. shell bottom temperature °F — Refrigerant circuitRef. pipe length ft. 25 Refrigerant charge (R454B) 2 lbs. 12 oz DB °F 80 70 Intake air temperature WB °F 67 60 DB °F 60 101 Discharge air temperature WB °F 59 — Indoor unitFan speed (High) rpm 970 900 Airflow (High) CFM 447 (wet) 477 DB °F 95 47 Intake air temperature WB °F — 43 Fan speed rpm 780 790 Outdoor unitAirflow CFM 1,303 1,321 OBD946_29 Model MSZ-FX15NL Item Unit COOL HEAT Capacity Btu/h 15,000 16,500 SHF — 0.81 — TotalInput kW 1.02 1.08 Rated frequency Hz 47 48 Indoor unit MSZ-FX15NL Power supply V, phase, Hz 208/230, 1, 60 Input kW 0.033 0.036 Fan motor current A 0.34/0.31 0.36/0.33 Outdoor unit MUZ-FX15NLHZ Power supply V, phase, Hz 208/230, 1, 60 Electrical circuitInput kW 0.987 1.044 Comp. current A 3.8/3.41 4.06/3.68 Fan motor current A 0.76/0.68 0.86/0.78 Condensing pressure psig 339 331 Suction pressure psig 132 106 Discharge temperature °F 157 152 Condensing temperature °F 108 38 Suction temperature °F 56 39 Comp. shell bottom temperature °F — Refrigerant circuitRef. pipe length ft. 25 Refrigerant charge (R454B) 3 lbs.7 oz DB °F 80 70 Intake air temperature WB °F 67 60 DB °F 59 99 Discharge air temperature WB °F 58 — Indoor unitFan speed (High) rpm 1,060 1,090 Airflow (High) CFM 504 (wet) 614 DB °F 95 47 Intake air temperature WB °F — 43 Fan speed rpm 740 800 Outdoor unitAirflow CFM 1,773 1,935 OBD946_30 Model MSZ-FX18NL Item Unit COOL HEAT Capacity Btu/h 17,200 17,000 SHF — 0.76 — TotalInput kW 1.32 1.39 Rated frequency Hz 59 58 Indoor unit MSZ-FX18NL Power supply V, phase, Hz 208/230, 1, 60 Input kW 0.033 0.036 Fan motor current A 0.34/0.31 0.36/0.33 Outdoor unit MUZ-FX18NLHZ Power supply V, phase, Hz 208/230, 1, 60 Electrical circuitInput kW 1.287 1.354 Comp. current A 5.4/4.91 5.48/4.99 Fan motor current A 0.76/0.68 0.86/0.78 Condensing pressure psig 349 359 Suction pressure psig 120 104 Discharge temperature °F 162 159 Condensing temperature °F 110 37 Suction temperature °F 48 37 Comp. shell bottom temperature °F — Refrigerant circuitRef. pipe length ft. 25 Refrigerant charge (R454B) 3 lbs. 7 oz DB °F 80 70 Intake air temperature WB °F 67 60 DB °F 57 104 Discharge air temperature WB °F 56 — Indoor unitFan speed (High) rpm 1,060 1,090 Airflow (High) CFM 504 (wet) 614 DB °F 95 47 Intake air temperature WB °F — 43 Fan speed rpm 740 800 Outdoor unitAirflow CFM 1,773 1,935 OBD946_31 Model MSZ-FX24NL Item Unit COOL HEAT Capacity Btu/h 20,800 19,800 SHF — 0.78 — TotalInput kW 1.56 1.50 Rated frequency Hz 52.5 48.5 Indoor unit MSZ-FX24NL Power supply V, phase, Hz 208/230, 1, 60 Input kW 0.056 0.064 Fan motor current A 0.53/0.48 0.59/0.53 Outdoor unit MUZ-FX24NLHZ Power supply V, phase, Hz 208/230, 1, 60 Electrical circuitInput kW 1.504 1.437 Comp. current A 5.97/5.42 5.75/5.19 Fan motor current A 1.1/1 0.86/0.78 Condensing pressure psig 345 336 Suction pressure psig 124 101 Discharge temperature °F 161 157 Condensing temperature °F 110 37 Suction temperature °F 52 37 Comp. shell bottom temperature °F — Refrigerant circuitRef. pipe length ft. 25 Refrigerant charge (R454B) 3 lbs. 6 oz DB °F 80 70 Intake air temperature WB °F 67 60 DB °F 61 95 Discharge air temperature WB °F 60 — Indoor unitFan speed (High) rpm 1,230 1,270 Airflow (High) CFM 612 (wet) 749 DB °F 95 47 Intake air temperature WB °F V 43 Fan speed rpm 900 800 Outdoor unitAirflow CFM 2,204 1,935 OBD946_32 7-5. CAPACITY AND INPUT CORRECTION BY INVERTER OUTPUT FREQUENCY MUZ-FX06NLHZ Correction of Cooling capacity Correction of Cooling total input Correction of Heating capacity Correction of Heating total input 2.5 4.5 2.5 3.5 4.0 3.0 2.0 3.5 2.0 2.5 3.0 1.5 2.5 1.5 2.0 2.0 1.5 1.0 1.0 1.5 1.0 0.5 1.0 0.5 Input correction factors Input correction factors0.5 Capacity correction factors 0.5 Capacity correction factors 0.0 0.0 0.0 0.0 0 50 100(Hz) 0 50 100(Hz) 0 50 100 150 (Hz) 0 50 100 150 (Hz) The operational frequency of compressor The operational frequency of compressor The operational frequency of compressor The operational frequency of compressor MUZ-FX09NLHZ Correction of Cooling capacity Correction of Cooling total input Correction of Heating capacity Correction of Heating total input 2.0 3.5 2.5 3.5 3.0 3.0 2.0 1.5 2.5 2.5 1.5 2.0 2.0 1.0 1.5 1.5 1.0 1.0 1.0 0.5 0.5 Input correction factors0.5 Input correction factors0.5 Capacity correction factors Capacity correction factors 0.0 0.0 0.0 0.0 0 50 100 (Hz) 0 50 100(Hz) 0 50 100 150 (Hz) 0 50 100 150 (Hz) The operational frequency of compressor The operational frequency of compressor The operational frequency of compressor The operational frequency of compressor MUZ-FX12NLHZ Correction of Cooling capacity Correction of Cooling total input Correction of Heating capacity Correction of Heating total input 2.0 2.5 2.5 3.0 2.5 2.0 2.0 1.5 2.0 1.5 1.5 1.0 1.5 1.0 1.0 1.0 0.5 0.5 0.5 Input correction factors Input correction factors0.5 Capacity correction factors Capacity correction factors 0.0 0.0 0.0 0.0 0 50 100(Hz) 0 50 100(Hz) 0 50 100 150(Hz) 0 50 100 150(Hz) The operational frequency of compressor The operational frequency of compressor The operational frequency of compressor The operational frequency of compressor MUZ-FX15NLHZ Correction of Cooling capacity Correction of Cooling total input Correction of Heating capacity Correction of Heating total input 2.0 2.5 2.5 3.0 2.5 2.0 2.0 1.5 2.0 1.5 1.5 1.0 1.5 1.0 1.0 1.0 0.5 0.5 0.5 Input correction factors Input correction factors0.5 Capacity correction factors Capacity correction factors 0.0 0.0 0.0 0.0 0 50 100(Hz) 0 50 100(Hz) 0 50 100 150(Hz) 0 50 100 150(Hz) The operational frequency of compressor The operational frequency of compressor The operational frequency of compressor The operational frequency of compressor OBD946_33 MUZ-FX18NLHZ Correction of Cooling capacity Correction of Cooling total input Correction of Heating capacity Correction of Heating total input 2.0 2.0 2.5 3.0 2.5 1.6 2.0 1.5 2.0 1.2 1.5 1.0 1.5 0.8 1.0 1.0 0.5 0.4 0.5 Input correction factors Input correction factors0.5 Capacity correction factors Capacity correction factors 0.0 0.0 0.0 0.0 0 50 100(Hz) 0 50 100(Hz) 0 50 100 150(Hz) 0 50 100 150(Hz) The operational frequency of compressor The operational frequency of compressor The operational frequency of compressor The operational frequency of compressor MUZ-FX24NLHZ Correction of Cooling capacity Correction of Cooling total input Correction of Heating capacity Correction of Heating total input 2.0 2.5 2.5 3.0 2.5 2.0 2.0 1.5 2.0 1.5 1.5 1.0 1.5 1.0 1.0 1.0 0.5 0.5 0.5 Input correction factors Input correction factors0.5 Capacity correction factors Capacity correction factors 0.0 0.0 0.0 0.0 0 50 100(Hz) 0 50 100(Hz) 0 50 100 150(Hz) 0 50 100 150(Hz) The operational frequency of compressor The operational frequency of compressor The operational frequency of compressor The operational frequency of compressor NOTE: 1. Data shown are estimated value. Performance may vary depending on operating conditions. 2. Conditions are based on AHRI 210/240. Rating conditions (Cooling) — Indoor: 80ËšFDB, 67ËšFWB, Outdoor: 95ËšFDB, (75ËšFWB) (Heating) — Indoor: 70ËšFDB, 60ËšFWB, Outdoor: 47ËšFDB, 43ËšFWB 7-6. HOW TO OPERATE FIXED-FREQUENCY OPERATION (Test run operation) 1. Press the emergency operation switch to start COOL or HEAT mode (COOL: Press once, HEAT: Press twice). 2. Test run operation starts and continues to operate for 30 minutes. 3. Compressor operates at rated frequency in COOL mode or 58 Hz in HEAT mode. 4. Indoor fan operates at High speed. 5. After 30 minutes, test run operation finishes and EMERGENCY OPERATION starts (operation frequency of compressor varies). 6. To cancel test run operation (EMERGENCY OPERATION), press the emergency operation switch or any button on remote controller. OBD946_34 8 ACTUATOR CONTROL MUZ-FX06NLHZ MUZ-FX09NLHZ MUZ-FX12NLHZ MUZ-FX15NLHZ MUZ-FX18NLHZ MUZ-FX24NLHZ 8-1. OUTDOOR FAN MOTOR CONTROL The fan motor turns ON/OFF, interlocking with the compressor. [ON] The fan motor turns ON 5 seconds before the compressor starts up. [OFF] The fan motor turns OFF 15 seconds after the compressor has stopped running. 5 seconds 15 seconds ON Compressor OFF ON Outdoor fan motor OFF 8-2. R.V. COIL CONTROL Heating ................. ON Cooling ................. OFF Dry ..................... OFF NOTE: The 4-way valve reverses for 5 seconds right before startup of the compressor. <COOL> <HEAT> 5 seconds 5 seconds ON Compressor OFF ON R.V.coil OFF Outdoor fan ON motor OFF 8-3. RELATION BETWEEN MAIN SENSOR AND ACTUATOR Actuator Sensor Purpose Outdoor fan Indoor fan Defrost Compressor LEV R.V.coil motor motor heater Discharge temperature Protection â—‹ â—‹ thermistor Indoor coil temperature Cooling: Coil frost prevention â—‹ thermistor Heating: High pressure protection â—‹ â—‹ Defrost thermistor Heating: Defrosting â—‹ â—‹ â—‹ â—‹ â—‹ Fin temperature Protection â—‹ â—‹ thermistor Ambient temperature Cooling: Low ambient temperature operation â—‹ â—‹ â—‹ thermistor Heating: Defrosting (Heater) â—‹ Outdoor heat exchanger Cooling: Low ambient temperature operation â—‹ â—‹ â—‹ temperature thermistor Cooling: High pressure protection â—‹ â—‹ â—‹ OBD946_35 9 SERVICE FUNCTIONS MUZ-FX06NLHZ MUZ-FX09NLHZ MUZ-FX12NLHZ MUZ-FX15NLHZ MUZ-FX18NLHZ MUZ-FX24NLHZ 9-1. CHANGE IN DEFROST SETTING Changing defrost finish temperature <JS> To change the defrost finish temperature, cut/solder the JS wire of the outdoor inverter P.C. board (Refer to 10-6.1.). Defrost finish temperature MUZ-FX06NLHZ MUZ-FX15NLHZ Jumper MUZ-FX09NLHZ MUZ-FX18NLHZ MUZ-FX12NLHZ MUZ-FX24NLHZ Soldered 46.4°F (8°C) 50°F (10°C) (Initial setting) JS None 55.4°F (13°C) 59°F (15°C) (Cut) 9-2. PRE-HEAT CONTROL SETTING Prolonged low load operation, in which the thermostat is OFF for a long time, at low outside temperature [32°F (0°C) or less] may cause the following troubles. To prevent those troubles, activate the pre-heat control. 1) If moisture gets into the refrigerant cycle and freezes, it may interfere the startup of the compressor. 2) If liquid refrigerant collects in the compressor, a failure in the compressor may occur. The pre-heat control turns ON when the compressor temperature is 68°F (20°C) or below. When the pre-heat control turns ON, the compressor is energized. (About 70 W) Pre-heat control setting <JK> ON: To activate the pre-heat control, cut JK wire of the inverter P.C. board. OFF: To deactivate the pre-heat control, solder JK wire of the inverter P.C. board. (Refer to 10-6.1) Jumper Pre-heat control setting Deactivated Soldered JK (Initial setting) Cut Activated NOTE: When the inverter P.C. board is replaced, check the jumper wires, and cut/solder them if necessary. OBD946_36 10 TROUBLESHOOTING MUZ-FX06NLHZ MUZ-FX09NLHZ MUZ-FX12NLHZ MUZ-FX15NLHZ MUZ-FX18NLHZ MUZ-FX24NLHZ 10-1. CAUTIONS ON TROUBLESHOOTING 1. Before troubleshooting, check the following 1) Check the power supply voltage. 2) Check the indoor/outdoor connecting wire for miswiring. 2. Take care of the following during servicing 1) Before servicing the air conditioner, be sure to turn OFF the main unit first with the remote controller, then after confirm- ing the horizontal vane is closed, turn off the breaker and/or disconnect the power plug. 2) Be sure to turn OFF the power supply before removing the front panel, the cabinet, the top panel, and the electronic control P.C. board. 3) When removing the electrical parts, be careful of the residual voltage of smoothing capacitor. 4) When removing the electronic control P.C. board, hold the edge of the board with care NOT to apply stress on the components. 5) When connecting or disconnecting the connectors, hold the connector housing. DO NOT pull the lead wires. <Incorrect> <Correct> Lead wiring Connector housing 3. Troubleshooting procedure 1) Check if the OPERATION INDICATOR lamp on the indoor unit is blinking on and off to indicate an abnormality. To make sure, check how many times the OPERATION INDICATOR lamp is blinking on and off before starting service work. 2) Before servicing, verify that all connectors and terminals are connected properly. 3) When the electronic control P.C. board seems to be defective, check for disconnection of the copper foil pattern and burnt or discolored components. 4) Refer to 10-2 and 10-3. OBD946_37 10-2. FAILURE MODE RECALL FUNCTION AND ERROR CODE DISPLAY MODE Outline of the function This air conditioner can memorize the failure which has occurred last time. Even though LED indication listed on the troubleshooting check table (10-3.) disappears, the memorized failure can be recalled. Also, error code can be checked on the display of remote controller while the left operation indicator lamp on the indoor unit is blinking. 1. Flow chart of failure mode recall function for the indoor/outdoor unit Operational procedure The cause of abnormality cannot be identified because the error code does not appear again. Setting up the failure mode recall function (Figure 1) Turn ON the power supply. <Preparation of the remote controller> While pressing Operation select button and TEMP button on the remote controller at the same time, press RESET button. First, release RESET button. Hold down the other 2 buttons for another 3 seconds. Make sure that the indicators on the LCD dis- play shown in Figure 1 have all appeared. (“00†is shown in the display.) Then release the buttons. Check of OPERATION INDICATOR lamp Check of error code on the display of remote controller An example of error code (00) Get close to the front of the indoor unit. Figure 1 Press OFF/ON (stop/operate) button of the remote controller with the remote controller headed towards the indoor unit. Did the indoor unit beep? Get closer to the indoor unit, then try again. No 1st Yes *1 Turn off the power of appliances such as fluorescent lamp and TV which might cause noise, then try again. 2nd (If the battery replacement indicator lights up, replace the batteries with new ones.) The indoor unit is normal, but the outdoor unit might be abnormal. How many beeps? There are some abnormalities that cannot be recalled with this way. 2 times Check if the outdoor unit is abnormal according to the outdoor unit failure mode 1 time recall function. (10-2.2.) The unit has an error. 00 E6 · · · · · · UP Press TEMP or to change an error code. Each press of TEMP changes the error code shown on the remote controller in ascending order (A to Z). (Figure 2) Each press of TEMP changes the error code in descending order (Z to A). Figure 2 Check the error code one by one to send the signal. How many beeps? The diagnosis has failed. Try again. No beeps 2 times 1 time The unit does not have the error corresponding to the error code shown on the remote controller. Continue checking. The unit has the error corresponding to the error code. Judgment of indoor/outdoor abnormality Is the error code in the table of The outdoor unit is abnormal. indoor unit failure mode recall Check the error code, and identify the abnormal point by referring to function? (Refer to indoor unit No the table of outdoor unit failure mode recall function. (10-2.4.) service manual.) Yes The indoor unit is abnormal. Check the error code, and identify the abnormal point by referring B (To next page) to the table of indoor unit failure mode recall function. (Refer to indoor unit service manual.) A (To next page) OBD946_38 A (From previous page) Press OFF/ON (stop/operate) button of the remote controller with the remote controller headed towards the indoor unit. *1. The indoor unit is normal, but the outdoor unit might be abnormal. Does the upper OPERATION INDICATOR lamp on There are some abnormalities that cannot be recalled with this way. the indoor unit blink at the interval of 0.5 seconds? No Check if the outdoor unit is abnormal according to the outdoor unit failure mode (OFF) recall function. (10-2-2.) Yes (Blinks) NOTE: It takes up to 1 minute to indicate the outdoor unit abnormality. Even if the OPERATION INDICATOR lamp is not blinking, keep checking Judgment of indoor/outdoor abnormality at least 1 minute or longer. Before blinking, does the upper OPERATION INDICATOR lamp stay ON for 3 seconds? Yes No The indoor unit is abnormal. The outdoor unit is abnormal. Check the blinking pattern, and identify the abnormal point by referring to the Check the blinking pattern, and identify the abnormal point by referring table of indoor unit failure mode recall function. (Refer to the indoor unit service to the table of outdoor unit failure mode recall function. (10-2-4.) manual.) Make sure to check at least 2 consecutive blinking cycles. *2 Make sure to check at least 2 consecutive blinking cycles. *3 B (From previous page) Releasing the failure mode recall function Release the failure mode recall function by the following procedures. Turn OFF the power supply and turn it ON again. Press RESET button of the remote controller. Repair the failure parts. Deleting the memorized abnormal condition After repairing the unit, recall the failure mode again according to “Setting up the failure mode recall function†mentioned above. Press OFF/ON (stop/operate) button of the remote controller with the remote controller headed towards the indoor unit. Press the emergency operation switch so that the memorized abnormal condition is deleted. Release the failure mode recall function according to “Releasing the failure mode recall function†mentioned above. NOTE: 1. Make sure to release the failure mode recall function after it is set up, otherwise the unit cannot operate properly. 2. If the abnormal condition is not deleted from the memory, the last abnormal condition is kept memorized. *1. Regardless of normal or abnormal condition, 2 short beeps are emitted once the signal is received. *2. Blinking pattern when the indoor unit is abnormal: Blinking at 0.5- Blinking at 0.5- 2.5-second OFF second interval 2.5-second OFF second interval ON OFF Repeated cycle Repeated cycle Repeated cycle *3. Blinking pattern when the outdoor unit is abnormal: Blinking at 0.5- Blinking at 0.5- 2.5-second OFF 3-second ON second interval 2.5-second OFF 3-second ON second interval ON OFF Repeated cycle Repeated cycle Repeated cycle OBD946_39 2. Flow chart of the outdoor unit failure mode recall function Operational procedure The outdoor unit might be abnormal. Check if the outdoor unit is abnormal according to the following procedures. Make sure that the remote controller is set to the failure mode recall function. Get close to the front of the indoor unit. With the remote controller headed towards the indoor unit, press button to set the indicator shown in Figure 1 to 25. *1 (Figure 1) Figure 1 Check of OPERATION INDICATOR lamp Check of error code on the display of remote controller “00†is shown in the display. (Figure 1) How many beeps? 2 times 1 time 00 E8 · · · · · · UP The outdoor unit has an error. Figure 2 Press TEMP or to change an error code. Each press of TEMP changes the error code shown on the remote controller in ascending order (A to Z). (Figure 2) Each press of TEMP changes the error code in descending order (Z to A). Check the error code one by one to send the signal. The diagnosis has failed. How many beeps? No beeps Try again. 2 times 1 time The unit does not have the error corresponding to the error code shown on the remote controller. Continue checking. The unit has the error corresponding to the error code. The outdoor unit is abnormal. Check the error code, and identify the abnormal point by referring A (To next page) to the table of outdoor unit failure mode recall function (10-2.4.). Does the left OPERATION INDICATOR lamp on the The outdoor unit is normal. indoor unit blink at the interval of 0.5 seconds? *2 No (OFF) Yes (Blinks) The outdoor unit is abnormal. Check the blinking pattern, and identify the abnormal point by referring to the table of outdoor unit failure mode recall function (10-2.4.). Make sure to check at least 2 consecutive blinking cycles. *2 A (To next page) OBD946_40 A (From previous page) Releasing the failure mode recall function Release the failure mode recall function by the following procedures. Turn OFF the power supply and turn it ON again. Press RESET button of the remote controller. Repair the failure parts. Deleting the memorized abnormal condition After repairing the unit, recall the failure mode again according to “Setting up the failure mode recall function†(10-2.1.). Press STOP/OPERATE (OFF/ON) button of the remote controller with the remote controller headed towards the indoor unit. Press EMERGENCY OPERATION switch so that the memorized abnormal condition is deleted. Release the failure mode recall function according to “Releasing the failure mode recall function†mentioned above. NOTE: 1. Make sure to release the failure mode recall function after it is set up, otherwise the unit cannot operate properly. 2. If the abnormal condition is not deleted from the memory, the last abnormal condition is kept memorized. *1. Regardless of normal or abnormal condition, 2 short beeps are emitted once the signal is received. *2. Blinking pattern when outdoor unit is abnormal: Blinking at 0.5- Blinking at 0.5- 2.5-second OFF 3-second ON second interval 2.5-second OFF 3-second ON second interval ON OFF Repeated cycle Repeated cycle Repeated cycle OBD946_41 3. Flow chart of error code display mode This explains how customers can check the error code on their own. This is included in OPERATING INSTRUCTIONS. Operational procedure The remote controller is powered OFF. Get close to the front of the indoor unit. Point the remote controller at the receiving section of the indoor unit, and keep pressing CHECK with a fine-tipped object until the beeps. (Figure 1) “00†is shown in the display. (Figure 2) Figure 1 Did the indoor unit beep? Get closer to the indoor unit, then try again. No 1st Yes Turn off the power of appliances such as fluorescent lamp and TV which might cause noise, then try again. 2nd (If the battery replacement indicator lights up, replace the batteries with new ones.) The indoor unit is normal, but the outdoor unit might be abnormal. There are some abnormalities that cannot be recalled with this way. How many beeps? 2 times Check if the outdoor unit is abnormal according to the outdoor unit failure mode recall function. (10-2.2.) 1 time The unit has an error. Press TEMP or to change an error code. Figure 2 Each press of TEMP changes the error code shown on the remote controller in ascending order (A to Z). (Figure 3) NOTE: Even though the air Each press of TEMP changes the error code in descending order (Z to A). conditioner operates normally, Check the error code one by one to send the signal. the memorized indication for the last error appears if it has not been deleted. How many beeps? The diagnosis has failed. Try again. No beeps 2 times 1 time 00 E6 · · · · · · UP The unit does not have the error corresponding to the error code shown on the remote Figure 3 controller. Continue checking. The unit has the error corresponding to the error code. Refer to the error code on the table of indoor unit failure mode recall function (refer to indoor unit service manual) or the table of outdoor unit failure mode recall function (10-2.4). OBD946_42 4. Table of outdoor unit failure mode recall function OPERATION Indoor/outdoor Outdoor unit INDICATOR Error Abnormal point LED indication unit failure Condition Remedy failure mode lamp code (Failure mode/protection) (Outdoor P.C. board) mode recall recall function (Indoor unit) function Not blink 00 None (Normal) — — — — — 1-time blink Indoor/outdoor • Refer to 10-5. “How Any signals from the inverter 2.5 seconds communication, to check miswiring E8 — P.C. board cannot be received OFF receiving error and serial signal normally for 3 minutes. errorâ€. Indoor/outdoor Although the inverter P.C. • Refer to 10-5. “How E9 communication, — board sends signal “0â€, signal to check miswiring â—‹ â—‹ receiving error “1†has been received and serial signal 30 consecutive times. errorâ€. Indoor/outdoor The start-up process of the • Replace the indoor EC communication, — outdoor unit does not complete electronic control P.C. start-up process abnormality for 4 minutes. board. 2-time blink Outdoor power system Overcurrent protection cut-out • Reconnect 2.5 seconds operates 3 consecutive times connectors. OFF within 1 minute after the • Refer to 10-5. “How UP — compressor gets started. to check inverter/ â—‹ â—‹ compressorâ€. • Check stop valve. 3-time blink Discharge temperature 1-time blink every Thermistor shorts or opens • Refer to 10-5. U3 2.5 seconds thermistor 2.5 seconds during compressor running. “Check of outdoor OFF Defrost thermistor thermistorsâ€. Defective outdoor Ambient temperature 2-time blink thermistors can be 2.5 seconds OFF identified by checking Fin temperature thermistor 3-time blink the blinking pattern of â—‹ â—‹ U4 2.5 seconds OFF LED. Outdoor heat exchanger — temperature thermistor P.C. board temperature 4-time blink • Replace the inverter thermistor 2.5 seconds OFF P.C. board. 4-time blink Overcurrent 11-time blink Large current flows into power • Reconnect 2.5 seconds 2.5 seconds OFF module (IC700). compressor connector. OFF • Refer to 10-5. “How — â—‹ to check inverter/ compressorâ€. UF • Check stop valve. Compressor synchronous 12-time blink Waveform of compressor • Reconnect — â—‹ abnormality 2.5 seconds OFF current is distorted. compressor connector. Compressor start-up failure Overcurrent cutoff within 10 • Refer to 10-5. “How 13-time blink to check inverter/ protection seconds after activating the — â—‹ 2.5 seconds OFF compressorâ€. compressor. 5-time blink Discharge temperature Temperature of discharge • Check refrigerant 2.5 seconds temperature thermistor circuit and refrigerant OFF exceeds 241°F (116°C), amount. compressor stops. • Refer to 10-5. U2 — — â—‹ Compressor can restart if “Check of LEVâ€. discharge temperature thermistor reads 212°F (100°C) or less 3 minutes later. 6-time blink High pressure Temperature of outdoor heat • Check refrigerant 2.5 seconds exchanger temperature circuit and refrigerant Ud — — â—‹ OFF thermistor exceeds 158°F amount. (70°C) in COOL mode. • Check stop valve. 7-time blink Fin temperature 7-time blink Temperature of fin temperature • Check around outdoor 2.5 seconds U5 2.5 seconds OFF thermistor on the inverter P.C. unit. OFF board exceeds 167 - 187°F (75 • Check outdoor unit air - 86°C), or temperature of P.C. passage. P.C. board temperature board temperature thermistor • Refer to 10-5. — â—‹ Ub on the inverter P.C. board “Check of outdoor fan exceeds 162 - 185°F (72 motorâ€. - 85°C). 8-time blink Outdoor fan motor Outdoor fan has stopped 3 • Refer to 10-5. 2.5 seconds times in a row within 30 “Check of outdoor fan OFF U8 — seconds after outdoor fan motorâ€. Refer to 10-5. — â—‹ start-up. “Check of inverter P.C. boardâ€. NOTE: Blinking patterns of this mode differ from the ones of TROUBLESHOOTING CHECK TABLE (10-3.). OBD946_43 NOTE: Blinking patterns of this mode differ from the ones of TROUBLESHOOTING CHECK TABLE (10-3.). OPERATION Indoor/outdoor Outdoor unit INDICATOR Error Abnormal point LED indication unit failure Condition Remedy failure mode lamp code (Failure mode/protection) (Outdoor P.C. board) mode recall recall function (Indoor unit) function 9-time blink Nonvolatile memory data 5-time blink Nonvolatile memory data • Replace the inverter 2.5 seconds FC 2.5 seconds OFF cannot be read properly. P.C. board. â—‹ â—‹ OFF Power module (IC700) 6-time blink The interface short circuit • Refer to 10-5. “How 2.5 seconds OFF occurs in the output of the to check inverter/ U6 power module (IC700). compressorâ€. — â—‹ The compressor winding shorts circuit. 10-time blink Discharge temperature Temperature of discharge • Refer to 10-5. 2.5 seconds temperature thermistor has “Check of LEVâ€. OFF U7 — been 122°F (50°C) or less for • Check refrigerant — â—‹ 20 minutes. circuit and refrigerant amount. 11-time blink Bus-bar voltage (DC) 8-time blink Bus-bar voltage of inverter • Refer to 10-5. “How UJ 2.5 seconds 2.5 seconds OFF cannot be detected normally. to check inverter/ OFF Each phase current of 9-time blink Each phase current of compressorâ€. — â—‹ UH compressor 2.5 seconds OFF compressor cannot be detected normally. 13-time blink Abnormal of wrong voltage When 100 V power supply is • Check power supply 2.5 seconds Fd power supply connected. — connected to 200 V model. voltage â—‹ â—‹ OFF 14-time blink Stop valve (Closed valve) 14-time blink • Closed valve is detected by • Check stop valve. 2.5 seconds 2.5 seconds OFF compressor current. • Refer to “TEST POINT OFF *1 • An abnormality of the indoor DIAGRAM AND thermistors is detected. VOLTAGE†on the service manual of UE indoor unit for the â—‹ â—‹ characteristics of the thermistors. (Do not start the operation again without repair to prevent hazards.) Pipe temperature 16-time blink • The indoor coil thermistor • Replace the inverter 2.5 seconds OFF detects an abnormal P.C. board. temperature. • Refer to “TEST POINT • An abnormality of the indoor DIAGRAM AND thermistors is detected. VOLTAGE†on the service manual of P8 indoor unit for the â—‹ â—‹ characteristics of the thermistors. (Do not start the operation again without repair to prevent hazards.) 16-time blink Outdoor refrigerant system 1-time blink • A closed valve and air • Check for a gas leak 2.5 seconds abnormality 2.5 seconds OFF trapped in the refrigerant in a connecting piping OFF *1 circuit are detected based on etc. the temperature sensed by • Check the stop valve. the indoor and outdoor • Refer to 10-5. thermistors and the current of “Check of outdoor the compressor. refrigerant circuitâ€. • An abnormality of the indoor • Refer to “TEST POINT PL thermistors is detected. DIAGRAM AND â—‹ â—‹ VOLTAGE†on the service manual of indoor unit for the characteristics of the thermistors. (Do not start the operation again without repair to prevent hazards.) *1 There is possibility that diesel explosion may occur due to the air mixed in the refrigerant circuit. First, ensure that there are no leakage points on the valves, flare connections, etc. that allow the air to flow into the refrigerant circuit, or no blockage points (e.g. clogged or closed valves) in the refrigerant circuit that cause an increase in pressure. If there is no abnormal point like above and the system operates cooling mode normally, the indoor thermistor might have a problem, resulting in false detection. Check both the indoor coil thermistor and the room temperature thermistor, and replace faulty thermistor(s), if any. NOTE: Do not start the operation again without repair to prevent hazards. OBD946_44 10-3. TROUBLESHOOTING CHECK TABLE Abnormal point/ No. Symptom LED indication Condition Remedy Condition Outdoor unit 1-time blink every Outdoor power Overcurrent protection cut-out operates 3 consecutive times • Reconnect connector of does not 2.5 seconds system within 1 minute after the compressor gets started. compressor. 1 operate. • Refer to 10-5. “How to check inverter/compressorâ€. • Check stop valve. Outdoor thermistors Discharge temperature thermistor, fin temperature thermistor, • Refer to 10-5. “Check of out- defrost thermistor, outdoor heat exchanger temperature door thermistorsâ€. thermistor or ambient temperature thermistor shorts or opens 2 during compressor running. P.C. board temperature thermistor shorts or opens during • Replace inverter P.C. board. compressor running. Outdoor control Nonvolatile memory data cannot be read properly. • Replace inverter P.C. board. system 3 (The left lamp of the OPERATION INDICATOR lamp on the indoor unit lights up or blinks 7-time.) 6-time blink Serial signal The communication fails between the indoor and outdoor unit • Refer to 10-5. “How to check 4 2.5 seconds OFF for 3 minutes. miswiring and serial signal errorâ€. 11-time blink Stop valve/ Closed valve is detected by compressor current. • Check stop valve. 5 2.5 seconds OFF Closed valve FX06/09/12 Outdoor unit Outdoor unit is defective. • Refer to 10-2.2. “Flow chart of the 6 14-time blink (Other abnormality) detailed outdoor unit failure mode 2.5 seconds OFF recall functionâ€. 16-time blink 4-way valve/ The 4-way valve does not work properly. • Refer to 10-5. “Check of R.V. 7 2.5 seconds OFF Pipe temperature The indoor coil thermistor detects an abnormal temperature. coilâ€. • Replace the inverter P.C. board. 17-time blink Outdoor refrigerant A closed valve and air trapped in the refrigerant circuit are • Check for a gas leak in a con- 2.5 seconds OFF system abnormality detected based on the temperature sensed by the indoor and necting piping etc. 8 outdoor thermistors and the current of the compressor. • Check the stop valve. • Refer to 10-5. “Check of out- door refrigerant circuitâ€. ‘Outdoor unit 2-time blink Overcurrent Large current flows into the power module (IC700). • Reconnect connector of stops and 2.5 seconds OFF protection compressor. 9 restarts 3 • Refer to 10-5. “How to check minutes later’ inverter/compressorâ€. is repeated. • Check stop valve. 3-time blink Discharge Temperature of discharge temperature thermistor exceeds • Check refrigerant circuit and 2.5 seconds OFF temperature 241°F (116°C), compressor stops. Compressor can restart if refrigerant amount. 10 overheat protection discharge temperature thermistor reads 212°F (100°C) or less • Refer to 10-5. “Check of LEVâ€. 3 minutes later. 4-time blink Fin temperature Temperature of the fin temperature thermistor on the heat sink • Check around outdoor unit. 2.5 seconds OFF /P.C. board exceeds 167 - 187°F (75 - 86°C) (FX06/09/12)/167 - 176°F • Check outdoor unit air passage. temperature (75 - 80°C) (FX15/18/24) or temperature of P.C. board tem- • Refer to 10-5. “Check of out- 11 thermistor overheat perature thermistor on the inverter P.C.board exceeds 162 - door fan motorâ€. protection 185°F (72 - 85°C) (FX06/09/12)/158 - 167°F (70 - 75°C) (FX15/18/24). 5-time blink High pressure Indoor coil thermistor exceeds 158°F (70°C) in HEAT mode. • Check refrigerant circuit and 12 2.5 seconds OFF protection Defrost thermistor exceeds 158°F (70°C) in COOL mode. refrigerant amount. • Check stop valve. 8-time blink Compressor The waveform of compressor current is distorted. • Reconnect connector of 2.5 seconds OFF synchronous compressor. 13 abnormality • Refer to 10-5. “How to check inverter/compressorâ€. 10-time blink Outdoor fan motor Outdoor fan has stopped 3 times in a row within 30 seconds • Refer to 10-5. “Check of out- 2.5 seconds OFF after outdoor fan startup. door fan motorâ€. 14 • Refer to 10-5. “Check of inverter P.C. boardâ€. 12-time blink Each phase current Each phase current of compressor cannot be detected • Refer to 10-5. “How to check 15 2.5 seconds OFF of compressor normally. inverter/compressorâ€. 13-time blink Bus-bar voltage Bus-bar voltage of inverter cannot be detected normally. • It occurs with following case. 2.5 seconds OFF (DC) • Instantaneous power voltage drop. (Short time power failure) (FX15/18/24) 16 • Refer to 10-5. “Check of power supplyâ€. (FX15/18/24) • Refer to 10-5. “How to check inverter/compressorâ€. OBD946_45 Abnormal point/ No. Symptom LED indication Condition Remedy Condition Outdoor unit 1-time blink Deceleration of the FX06/09/12 When the input current exceeds approximately The unit is normal, but check the operates. 2.5 seconds OFF operational 10A, compressor frequency lowers. following. frequency of the • Check if indoor filters are 17 compressor by the FX15/18/24 Current from power outlet is nearing breaker clogged. current protection capacity. • Check if refrigerant is short. control • Check if indoor/outdoor unit air circulation is short cycled. 3-time blink Deceleration of the Temperature of indoor coil thermistor exceeds 131°F (55°C) in 2.5 seconds OFF operational HEAT mode, compressor frequency lowers. frequency of the compressor by the high pressure protection 18 Deceleration of the Indoor coil thermistor reads 46°F (8°C) or less in COOL mode, operational compressor frequency lowers. frequency of the compressor by the overcooling prevention of the indoor heat exchanger 4-time blink Deceleration of the Temperature of discharge temperature thermistor exceeds • Check refrigerant circuit and 2.5 seconds OFF operational 232°F (111°C), compressor frequency lowers. refrigerant amount. frequency of the • Refer to 10-5. “Check of LEVâ€. 19 compressor by the • Refer to 10-5. “Check of out- discharge door thermistorsâ€. temperature protection FX06/09/12 Outside When the outside temperature thermistor shorts or opens, • Refer to 10-5. “Check of out- 5-time blink temperature protective operation without that thermistor is performed. door thermistorsâ€. 20 2.5 seconds OFF thermistor protection Outdoor unit 7-time blink Low discharge Temperature of discharge temperature thermistor has been • Refer to 10-5. “Check of LEVâ€. 21 operates. 2.5 seconds OFF temperature 122°F (50°C) or less for 20 minutes. • Check refrigerant circuit and protection refrigerant amount. 8-time blink FX06/09/12 The overcurrent flows into IGBT(Q821) or the bus-bar voltage This is not malfunction. PAM 2.5 seconds OFF PAM protection reaches 394 V or more, PAM stops and restarts. protection will be activated in the PAM: Pulse following cases: Amplitude 1 Instantaneous power voltage Modulation drop. (Short time power failure) 2 When the power supply voltage 22 is high. FX15/18/24 Zero cross signal cannot be detected. • It occurs with following cases. Zero cross 1 Instantaneous power voltage detecting circuit drop. (Short time power failure) 2 Distortion of primary voltage • Refer to 10-5. “Check of power supplyâ€. 9-time blink Inverter check The connector of compressor is disconnected, inverter check • Check if the connector of the 2.5 seconds OFF mode mode starts. compressor is correctly con- 23 nected. Refer to 10-5. “How to check inverter/compressorâ€. NOTE: 1. The location of LED is illustrated at the right figure. Refer to 10-6.1. 2. LED is lit during normal operation. Inverter P.C. board MUZ-FX06/09/12NLHZ The blinking frequency shows the number of times the LED blinks after every 2.5-second OFF. (Example) When the blinking frequency is “2â€. 0.5-second ON 0.5-second ON LED Blinking → ON 2.5-second OFF 2.5-second OFF OFF MUZ-FX15/18/24NLHZ Blinking→ LED OBD946_46 10-4. TROUBLESHOOTING CRITERION OF MAIN PARTS MUZ-FX06NLHZ MUZ-FX09NLHZ MUZ-FX12NLHZ MUZ-FX15NLHZ MUZ-FX18NLHZ MUZ-FX24NLHZ Part name Check method and criterion Figure Defrost thermistor (RT61) Measure the resistance with a multimeter. Fin temperature thermistor (RT64) Refer to 10-6. “Test point diagram and voltageâ€, 1. “Inverter P.C. boardâ€, for the chart of thermistor. Ambient temperature thermistor (RT65) Outdoor heat exchanger temperature thermistor (RT68) Discharge temperature Measure the resistance with a multimeter. Before measurement, hold the thermistor (RT62) thermistor with your hands to warm it up. Refer to 10-6. “Test point diagram and voltageâ€, 1. “Inverter P.C. boardâ€, for the chart of thermistor. Compressor Measure the resistance between terminals using a multimeter. [Temperature: 14 – 104°F (-10 – 40°C)] Normal (Ω) WHT RED BLK MUZ-FX09NLHZ MUZ-FX12NLHZ W MUZ-FX06NLHZ MUZ-FX24NLHZ MUZ-FX15NLHZ MUZ-FX18NLHZ V U U-V U-W 1.82 – 2.48 1.30 – 1.77 0.60 – 0.82 V-W Outdoor fan motor Measure the resistance between lead wires using a multimeter. [Temperature: 14 – 104°F (-10 – 40°C)] Normal (Ω) WHT RED BLK Color of lead MUZ-FX06NLHZ MUZ-FX15NLHZ wire MUZ-FX09NLHZ MUZ-FX18NLHZ W MUZ-FX12NLHZ MUZ-FX24NLHZ V RED – BLK U BLK – WHT 30 – 46 WHT – RED R. V. coil (21S4) Measure the resistance using a multimeter. [Temperature: 14 – 104°F (-10 – 40°C)] Normal (kΩ) 1.88 - 2.29 Expansion valve coil Measure the resistance using a multimeter. (LEV) [Temperature: 14 – 104°F (-10 – 40°C)] Color of lead wire Normal (Ω) BRN – ORN BRN – WHT 37 – 54 RED – BLU RED – YLW Defrost heater Measure the resistance using a multimeter. [Temperature: 14 – 104°F (-10 – 40°C)] Normal (Ω) MUZ-FX06NLHZ MUZ-FX15NLHZ MUZ-FX09NLHZ MUZ-FX18NLHZ MUZ-FX12NLHZ MUZ-FX24NLHZ 802 – 990 396 – 461 OBD946_47 10-5. TROUBLESHOOTING FLOW A How to check inverter/compressor Disconnect the connector between the compressor and the power module (IC700). Check the voltage between terminals. See 10-5. “Check of open phaseâ€. Are the voltages balanced? Replace the inverter P.C. board. No Yes Check the compressor. See 10-5. “Check of compressorâ€. B Check of open phase â— With the connector between the compressor and the power module (IC700) disconnected, activate the inverter and check if the inverter is normal by measuring the voltage balance between the terminals. Output voltage is 50 - 130 V. (The voltage may differ according to the multimeter.) << Operation method>> Start cooling or heating operation by pressing the emergency operation switch on the indoor unit. (TEST RUN OPERATION: Refer to 7-6.) <<Measurement point>> At 3 points *Measure AC voltage between the lead wires at 3 points. BLK (U)-WHT (V) BLK (U)-RED (W) WHT(V)-RED (W) NOTE: 1. Output voltage varies according to power supply voltage. 2. Measure the voltage by analog type multimeter. 3. During this check, LED of the inverter P.C. board blinks 9 times. (Refer to 10-6.1.) C Check of compressor Refer to 10-5. “Check of compressor windingâ€. Replace the compressor. No Is the compressor normal? Yes Refer to 10-5. “Check of compressor operation timeâ€. Refer to 10-5. “Check of compressor start failureâ€. No Does the compressor operate continuously? Yes OK OBD946_48 D Check of compressor winding â—Disconnect the connector between the compressor and the power module (IC700), and measure the resistance between the compressor terminals. <<Measurement point>> At 3 points *Measure the resistance between the lead wires at 3 points. BLK-WHT BLK-RED WHT-RED <<Judgement>> Refer to 10-4. 0 [Ω] ················Abnormal [short] Infinite [Ω] ·······Abnormal [open] NOTE: Be sure to zero the ohmmeter before measurement. E Check of compressor operation time <<Judgement>> â— Connect the compressor and activate the inverter. Then measure the time until the inverter stops due to overcurrent. 0 second Compressor starts <<Operation method>> 1 second Abnormal Start heating or cooling operation by pressing the emergency (IC700 failure) operation switch on the indoor unit. (TEST RUN OPERATION: 2 seconds (Compressor winding short) Refer to 7-6.) Abnormal <<Measurement>> (Compressor lock out) Measure the time from the start of compressor to the stop of (Starting defect) compressor due to overcurrent. Abnormal (Poor contact) 10 seconds (Inverter P.C. board defect) (Disconnected connector) Abnormal (Refrigerant circuit defect) (Closed valve) 10 minutes Normal F Check of compressor start failure Confirm that ~ is normal. •Electrical circuit check . Contact of the compressor connector . Output voltage of inverter P.C. board and balance of them (See 10-5. ) . Direct current voltage between DB61(+) and (-) (FX06/09/12)/IC700(P) and (N) (FX15/18/24) on the inverter P.C. board . Voltage between outdoor terminal block S1-S2 Does the compressor run for 10 seconds or Check the refrigerant circuit. more after it starts? Yes Check the stop valve. No After the compressor is heated with a drier, Replace the compressor. does the compressor start? *1 No *1 Yes Heat the compressor with a drier for about 20 minutes. Compressor start failure. Activate pre-heat control. Do not recover refrigerant (Refer to 9-2. “PRE-HEAT CONTROL SETTINGâ€) gas while heating. Heating part OBD946_49 G Check of outdoor thermistors Disconnect the connector of thermistor in the inverter P.C. board (see below table), and measure the resistance of thermistor. Replace the thermistor except RT64. Is the resistance of thermistor normal? When RT64 is abnormal, replace the inverter P.C. (Refer to 10-6.1.) No board. Yes Reconnect the connector of thermistor. Turn ON the power supply and press the emergency operation switch. Does the unit operate for 10 minutes or more Replace the inverter P.C. board. without showing thermistor abnormality? No Yes OK (Cause is poor contact.) MUZ-FX06/09/12 Thermistor Symbol Connector, Pin No. Board Defrost RT61 Between CN641 pin1 and pin2 Discharge temperature RT62 Between CN641 pin3 and pin4 Fin temperature RT64 Between CN642 pin1 and pin2 Inverter P.C. board Ambient temperature RT65 Between CN643 pin1 and pin2 Outdoor heat exchanger temperature RT68 Between CN644 pin1 and pin3 MUZ-FX15/18/24 Thermistor Symbol Connector, Pin No. Board Defrost RT61 Between CN671 pin1 and pin2 Discharge temperature RT62 Between CN671 pin3 and pin4 Fin temperature RT64 Between CN673 pin1 and pin2 Inverter P.C. board Ambient temperature RT65 Between CN672 pin1 and pin2 Outdoor heat exchanger temperature RT68 Between CN671 pin5 and pin6 OBD946_50 H Check of R.V. coil MUZ-FX06/09/12 * First of all, measure the resistance of R.V. coil to check if the coil is defective. Refer to 10-4. * In case CN721 is disconnected or R.V. coil is open, voltage is generated between the terminal pins of the connector although no signal is being transmitted to R.V. coil. Check if CN721 is connected. Unit operates in COOL mode even if it is set to HEAT mode. Disconnect connector between the compressor and the power module Is there 208/230 V AC between CN721 (IC700). and on the inverter P.C. board Replace the inverter Turn ON the power supply and press 3 minutes after the power supply is turned No P.C. board. the emergency operation switch ON? twice (HEAT mode). Yes Replace the 4-way valve. Unit operates in HEAT mode even if it is set to COOL mode. Disconnect connector between the compressor and the power module Is there 208/230 V AC between CN721 (IC700). and on the inverter P.C. board Replace the inverter Turn ON the power supply and 3 minutes after the power supply is turned Yes P.C. board. press the emergency operation ON? switch once (COOL mode). No Replace the 4-way valve. MUZ-FX15/18/24 * First of all, measure the resistance of R.V. coil to check if the coil is defective. Refer to 10-4. * In case CN602 is disconnected or R.V. coil is open, voltage is generated between the terminal pins of the connector although no signal is being transmitted to R.V. coil. Check if CN602 is connected. Unit operates in COOL mode even if it is set to HEAT mode. Disconnect connector between the compressor and the power module Is there 208/230 V AC between CN602 (IC700). and on the inverter P.C. board Replace the inverter Turn ON the power supply and press 3 minutes after the power supply is turned No P.C. board. the emergency operation switch ON? twice (HEAT mode). Yes Replace the 4-way valve. Unit operates in HEAT mode even if it is set to COOL mode. Disconnect connector between the compressor and the power module Is there 208/230 V AC between CN602 (IC700). and on the inverter P.C. board Replace the inverter Turn ON the power supply and 3 minutes after the power supply is turned Yes P.C. board. press the emergency operation ON? switch once (COOL mode). No Replace the 4-way valve. OBD946_51 I Check of outdoor fan motor Disconnect the connectors CN931 and CN932 from the inverter P.C. board. Check the connection between the connector CN931 and CN932. Is the resistance between each terminal of outdoor fan motor normal? Yes (Refer to 10-4.) Disconnect CN932 from the inverter P.C. board, and No turn on the power supply. Rotate the outdoor fan motor manually and measure the voltage of CN931. Between 1(+) and 5(-) Between 2(+) and 5(-) Between 3(+) and 5(-) (Fixed to either 5 or 0 V DC) Does the voltage between each terminal become No 5 and 0 V DC repeatedly? Yes Does the outdoor fan motor rotate smoothly? No Yes Replace the outdoor fan motor. Replace the inverter P.C. board. J Check of power supply Disconnect the connector between the compressor and the power module (IC700). Rectify indoor/outdoor Turn ON power supply and press the emergency operation switch. connecting wire. Yes Does the left lamp of the Is there voltage 208/230 V AC Replace the indoor OPERATION INDICATOR lamp on between the indoor terminal electronic control P.C. No No the indoor unit light up? block S1 and S2? board. Yes Is there bus-bar voltage 260 - 370 V DC between DB61 (+) and DB61 (–) Does LED on the inverter P.C. (FX06/09/12)/294 - 370 V DC Replace the inverter board light up or blink? between IC700 (P) and (N) Yes No P.C. board. (Refer to 10-6.1.) (FX15/18/24) on the inverter P.C. board? (Refer to 10-6.1.) Yes No If lights up, OK. Check the electric parts in main circuit. If blinks, refer to 10-3. MUZ-FX06/09/12 MUZ-FX15/18/24 260 - 370 V DC DB61 IC932 P 294 -370 V DC N Inverter P.C board Inverter P.C. board (Solder side) IC700 (Solder side) OBD946_52 K Check of LEV (Expansion valve) Turn ON the power supply. <Preparation of the remote controller> While pressing both Operation select button and TEMP button on the remote controller at the same time, press RESET button. First, release RESET button. Hold down the other 2 buttons for another 3 seconds. Make sure that the indicators on the LCD screen shown in the right figure are all displayed. Then release the buttons. An example of error code (00) Press OFF/ON (stop/operate) button of the remote con- troller (the set temperature is displayed) with the remote controller headed towards the indoor unit. *1 Expansion valve operates in full-opening direction. *1. Regardless of normal or abnormal condition, a short beep Do you hear the expansion valve “click, is emitted once the signal is received. click·······â€? OK Do you feel the expansion valve vibrate Yes when touching it ? No Is LEV coil properly fixed to Properly fix the LEV coil to the expansion valve. the expansion valve? No Yes Measure each voltage between connector pins of CN724 on the inverter P.C. board. 1. Pin (-) — Pin (+) Does the resistance of LEV 2. Pin (-) — Pin (+) Replace the inverter P.C. coil have the characteristics? 3. Pin (-) — Pin (+) Yes No board. (Refer to 10-4.) 4. Pin (-) — Pin (+) No Is there about 3 - 5 V DC between each? NOTE: Measure the voltage by an analog Replace the LEV coil. multimeter. Yes Replace the expansion valve. NOTE: After check of LEV, take the following steps. 1. Turn OFF the power supply and turn it ON again. 2. Press RESET button on the remote controller. OBD946_53 L Check of inverter P.C. board Check the outdoor fan motor. (Refer to 10-5. .) Is the fuse (F901) blown on the inverter P.C. board? Yes No Check the connection of the connectors (CN931, CN932) of the outdoor fan motor. If the connection is poor, make it correct. Operate the outdoor unit by starting EMERGENCY OPERATION. Check the LED indication on the Check the corresponding parts inverter P.C. board. following LED indication. No Does the LED blink 10 times? (Refer to 10-3.) Yes (10-time blink) Replace the inverter P.C. board. OBD946_54 M How to check miswiring and serial signal error Turn ON the power supply. Is there rated voltage in the power supply? Check the power supply. No Yes Is there rated voltage between outdoor terminal block S1 and S2? Check the wiring. No Yes Press the emergency operation switch once. Does the OPERATION INDICATOR lamp light up? <Confirmation of the power to the indoor No unit> Yes Is there any miswiring, poor contact, or wire Is serial signal error indicated 6 minutes disconnection of the Correct them. later? No Yes indoor/outdoor connect- Yes ing wire? No • Turn OFF inverter-controlled lighting equipment. • Turn OFF the power supply and then turn ON again. • Press the emergency operation switch. • Reinstall either the unit or the light away from each Is serial signal error indicated 6 minutes other. later? No • Attach a filter on remote control receiving section of the Yes indoor unit. *1. Miswiring may damage indoor electronic control P.C. Turn OFF the power supply. board during the operation. Check once more if the indoor/outdoor connecting Be sure to confirm the wiring is correct before the opera- wire is not miswiring. tion starts. Bridge the outdoor terminal block S2 and S3. *1 Turn ON the power supply. Is the bus-bar voltage of the inverter P.C. board normal? (Refer to “TEST POINT DIAGRAM AND VOLTAGE†in the outdoor service manual.) No Yes Does the LED on the inverter P.C. board repeat “3.6-second-OFF and Replace the inverter P.C. board. *2 0.8-second-ON quick blinkingâ€? *3 No (Lit or not Yes *2. Be careful of the residual voltage of smoothing lit) capacitor. *3. Be sure to check this within 3 minutes after Turn OFF the power supply. turning ON. After 3 minutes, LED blinks 6 Remove the bridge between outdoor terminal block S2 and S3. times. Even when the inverter P.C. board or the outdoor electronic control P.C. board is normal, LED blinks 6 times after 3 minutes. Replace the indoor electronic control P.C. board. (Except for outdoor unit of multi system type) OBD946_55 N Check of defrost heater Check the following points before checking electric continuity. 1. Does the resistance of ambient temperature thermistor have the characteristics? Refer to 10-6.1. 2. Is the resistance of defrost heater normal? Refer to 10-4. 3. Does the heater protector remain conducted (not open)? 4. Are both ambient temperature thermistor and circuit of defrost heater securely connected to connectors? In HEAT mode, for more than 5 minutes, let the ambient temperature thermistor continue to read 32°F (0°C) or below, and let the defrost thermistor continue to read 30°F (-1°C) or below. NOTE: In case both thermistors are more than the above temperature, cool them with cold water etc. Is there 208/230 V AC between CN601 and Not the problem of the inverter P.C. board. on the inverter P.C. board? Refer to 10-6.1. Yes No Replace the inverter P.C. board. O Check of outdoor refrigerant circuit The operation has stopped to prevent the diesel explosion Has the operation stopped during pump down? caused by air trapped in the refrigerant circuit. Close the stop Yes valve, and disconnect the power plug or turn the breaker OFF. No CAUTION : Do not start the operation again to prevent hazards. The unit occasionally stops when the stop valve is opened or Was the operation started with the stop valve closed during operation. Open the stop valve and start the closed, and was it opened during operation? Yes cooling operation again. No The refrigerant gas amount may be 60% or less than the normal amount. Identify where the gas is leaking from, and fix the leak. OBD946_56 P Check of compressor protector Disconnect the connector of compressor protector in the inverter P.C. board, and check the conduc- tion of compressor protector. Operate the unit Is the discharge temperature Is the compressor and re-confirm if thermistor normal? Refer to 10-5. protector conductive? Yes “Check of outdoor thermistorsâ€. Yes the abnormality occur. No No Take time until the temperature of the com- Replace the discharge pressor protector is lowered to ordinary temperature thermistor. temperature. Is the compressor protector conductive? Yes No Replace the compressor protector. OBD946_57 Q Electromagnetic noise enters into TV sets or radios Is the unit grounded? Ground the unit. No Yes Is the distance between the antennas Extend the distance between the antennas and and the indoor unit within 9.91 ft. (3m), the indoor unit, and/or the antennas and the out- or is the distance between the antennas Yes door unit. and the outdoor unit within 9.91 ft. (3m)? No Is the distance between the TV sets or radios and the indoor unit within 3.28 ft. Extend the distance between the TV sets and/or (1m), or is the distance between the TV radios and the indoor unit, or the TV sets or Yes sets or radios and the outdoor unit within radios and the outdoor unit. 9.91 ft. (3m)? No Are the antennas damaged? Is the coaxial cable damaged? Replace or repair the antenna. Is there any poor contact in the Yes Replace or repair the coaxial cable. antenna wiring? No Is the indoor/outdoor connecting wire Extend the distance between the indoor/outdoor of the air conditioner and the wiring of connecting wire of the air conditioner and the Yes the antennas close? wiring of the antennas. No Even if all of the above conditions are fulfilled, the electromagnetic noise may enter, depending on the electric field strength or the installation condition (combination of specific conditions such as antennas or wiring). Check the following before asking for service. 1. Devices affected by the electromagnetic noise TV sets, radios (FM/AM broadcast, shortwave) 2. Channel, frequency, broadcast station affected by the electromagnetic noise 3. Channel, frequency, broadcast station unaffected by the electromagnetic noise 4. Layout of: indoor/outdoor unit of the air conditioner, indoor/outdoor wiring, ground wire, antennas, wiring from antennas, receiver 5. Electric field intensity of the broadcast station affected by the electromagnetic noise 6. Presence or absence of amplifier such as booster 7. Operation condition of air conditioner when the electromagnetic noise enters in 1) Turn OFF the power supply once, and then turn ON the power supply. In this situation, check for the electromagnetic noise. 2) Within 3 minutes after turning ON the power supply, press OFF/ON (stop/operate) button on the remote controller for power ON, and check for the electromagnetic noise. 3) After a short time (3 minutes later after turning ON), the outdoor unit starts running. During operation, check for the electromagnetic noise. 4) Press OFF/ON (stop/operate) button on the remote controller for power OFF, when the outdoor unit stops but the indoor/outdoor communication still runs on. In this situation, check for the electromagnetic noise. OBD946_58 10-6. TEST POINT DIAGRAM AND VOLTAGE 1. Inverter P.C. board MUZ-FX06NLHZ MUZ-FX09NLHZ MUZ-FX12NLHZ Back side of unit Smoothing Smoothing Heater R.V.coil capacitor capacitor (CN722) (CN721) DB61 (C61) (C62) 208/230V AC 208/230 V AC 260 - 370 V DC (-) (+) Fuse (F62) Fuse (F801) Fuse (F701) 208/230 V AC 15 A 250 V T3.15AL250V T3.15AL250V Compressor protector (CN64) Output to drive Fuse (F61) compressor 25 A 250V (LDU, LDV, 208/230 LDW) V AC Fin Jumper wire temperature for changing thermistor/ defrost RT64 (CN642) setting (JS) Jumper wire for pre-heat Fuse (F901) control T3.15AL250V setting (JK) LED Expansion valve coil/LEV (CN724) Output to drive Signal of Ambient Outdoor heat Discharge temperature outdoor fan outdoor fan temperature exchanger thermistor/RT62 (CN641) motor (CN932) motor thermistor/ temperature Defrost thermistor/ Front side of unit (CN931) RT65 (CN643) thermistor/ RT61 (CN641) RT68 (CN644) Defrost thermistor(RT61) Ambient temperature thermistor(RT65) Outdoor heat exchanger temperature thermistor(RT68) Fin temperature thermistor(RT64) 100 200 90 180 80 Discharge temperature thermistor (RT62) 160 800 70 140 700 60 120 600 50 100 500 40 80 400 Resistance(kΩ)30 300 Resistance(kΩ)60 20 Resistance (kΩ)200 40 10 100 20 0 0 0 -4 14 32 50 68 86 104 32 50 68 86 104 122 140 158 176 194 212 230 248 32 50 68 86 104 122 140 158176 Temperature(°F) Temperature (°F) Temperature(°F) OBD946_59 MUZ-FX15NLHZ MUZ-FX18NLHZ MUZ-FX24NLHZ Smoothing Smoothing Smoothing Output to drive Capacitor Capacitor Capacitor Fuse (F880) outdoor fan motor Heater (CN601) Back side of unit (CB1) (CB2) (CB3) T3.15AL250V (CN932) 208/230 V AC Fuse (F601) T3.15AL250V 208/230 V AC Fuse (F62) R.V. coil/ 15 A 250 V 21S4 (CN602) Fuse (F901) 208/230 V AC T3.15AL250V LED Output to drive compressor Jumper wire (LDU, LDV, for pre-heat LDW) control setting (JK) IC700 (P) 294 - 370 V DC Fuse (F61) 25 A 250V IC700 (N) Jumper wire for changing Front side of unit Defrost thermistor Signal of Expansion valve defrost /RT61 (CN671) outdoor fan coil/LEV (CN724) setting (JS) motor (CN931) Compressor Discharge Outdoor heat Ambient Fin protector temperature exchanger temperature temperature (CN64) thermistor temperature thermistor thermistor /RT62 thermistor /RT65 /RT64 (CN671) /RT68 (CN672) (CN673) (CN671) Defrost thermistor(RT61) Ambient temperature thermistor(RT65) Outdoor heat exchanger temperature thermistor(RT68) Fin temperature thermistor(RT64) 100 200 90 180 80 Discharge temperature thermistor (RT62) 160 800 70 140 700 60 120 600 50 100 500 40 80 400 Resistance(kΩ)30 300 Resistance(kΩ)60 20 Resistance (kΩ)200 40 10 100 20 0 0 0 -4 14 32 50 68 86 104 32 50 68 86 104 122 140 158 176 194 212 230 248 32 50 68 86 104 122 140 158176 Temperature(°F) Temperature (°F) Temperature(°F) OBD946_60 2. Fuse P.C. board MUZ-FX15NLHZ MUZ-FX18NLHZ MUZ-FX24NLHZ FUSE (F66) T6.3AL250V FUSE (F65) T6.3AL250V OBD946_61 11 DISASSEMBLY INSTRUCTIONS <Detaching method of the terminal with locking mechanism> The terminal which has the locking mechanism can be detached as shown below. There are 2 types of the terminal with locking mechanism. The terminal without locking mechanism can be detached by pulling it out. Check the shape of the terminal before detaching. (1) Slide the sleeve and check if there is a locking lever or not. (2) The terminal with the connector shown below has the locking mechanism. Sleeve Slide the sleeve. Hold the sleeve, and Pull the terminal while pull out the terminal slowly. pushing the locking lever. Locking lever Connector 11-1. MUZ-FX06NLHZ MUZ-FX09NLHZ MUZ-FX12NLHZ : Indicates the visible parts in the photos/figures. NOTE: Turn OFF the power supply before disassembly. : Indicates the invisible parts in the photos/figures. OPERATING PROCEDURE PHOTOS/FIGURES 1. Removing the cabinet Photo 1 (1) Remove the screws of the service panel. (2) Remove the screws of the top panel. Screws of (3) Remove the screw of the valve cover. the top panel (4) Remove the service panel. (5) Remove the top panel. (6) Remove the valve cover. (7) Remove the screws fixing the conduit cover. (Photo 5) (8) Remove the conduit cover. (9) Remove the screw fixing the conduit plate. (Photo 6) (10) Remove the conduit plate. Screws of Screws of (11) Disconnect the power supply cord and indoor/outdoor the cabinet the cabinet connecting wire. (12) Remove the screws of the cabinet. Photo 2 Screws of the (13) Remove the cabinet. top panel (14) Remove the screws of the back panel. (15) Remove the back panel. NOTE: If the red labels have been removed during the operation, put them back in the original position Screws of after the operation. Red labels indicate the use of the cabinet flammable refrigerants. (Figure 1) Screws of the Photo 4 service panel Screw of the valve cover Photo 3 Figure 1 Screws of the back panel Direction to remove Hooks of the Red label service panel OBD946_62 OPERATING PROCEDURE PHOTOS/FIGURES Photo 5 Photo 6 Screws of the conduit cover Screw of the conduit plate (These screws are different shape from the other (This screw is different in shape from the other screws. Do not mix them with the other screws.) screws. Do not mix them with the other screws.) 2. Removing the inverter assembly and inverter P.C. Photo 7 board Screw of the heat sink (1) Remove the cabinet and panels (refer to section 1). support and the separator PB cover (2) Disconnect the lead wire to the reactor and the following connectors: <Inverter P.C. board> CN721 (R.V. coil) CN931, CN932 (Fan motor) CN641 (Defrost thermistor and discharge temperature thermistor) CN643 (Ambient temperature thermistor) CN644 (Outdoor heat exchanger temperature thermistor) CN724 (Expansion valve coil) CN722 (Defrost heater and heater protector) CN64 (Compressor protector) (3) Remove the compressor connector (CN61). (4) Remove the screws fixing the heat sink support and the separator. (5) Remove the inverter assembly. (6) Remove the screws of the ground wires. (7) Remove the heat sink support from the P.C. board sup- port. (Photo 9) (8) Remove the PB cover. Photo 8 (9) Remove the screw of the inverter P.C. board and Lead wires of the remove the inverter P.C. board from the P.C. board sup- defrost heater port. (Photo 10) OBD946_63 OPERATING PROCEDURE PHOTOS/FIGURES * Connection procedure when attaching the inverter Photo 11 Lead wires of the heat exchanger P.C. board (Photo 11) Lead wires of the temperature, the discharge tem- 1. Connect the lead wires of the heat exchanger tempera- ambient temperature perature and the defrost thermistor ture thermistor, the defrost thermistor and discharge thermistor temperature thermistor to the connector on the inverter P.C. board. Pull the lead wires toward you and put them Inverter P.C. Lead wires of the on the center hook on the P.C. board support. board support expansion valve coil 2. Connect the lead wires of the expansion valve coil to the connector on the inverter P.C. board. Pull the lead wires toward you and put them on the right hook on the P.C. board support. 3. Connect the lead wires of the ambient temperature thermistor to the connector on the inverter P.C. board. Pull the lead wires toward you and put them on the left hook on the P.C. board support so that the fan motor lead wires are bundled up as shown in Photo 11. 4. Hook the lead wires of the defrost heater and the heater protector. (Photo 8) Photo 9 (Inverter assembly) Heat sink Heat sink support P.C. board support Pass the lead wire of Connector of the compressor protector compressor protector through the top felt Inverter P.C. board hole. Fix the lead wires of the Screws of compressor protector and the ground wire the compressor. Photo 10 Catches of the inverter P.C.board Screw of the inverter P.C. board Catches of the inverter P.C.board OBD946_64 OPERATING PROCEDURE PHOTOS/FIGURES 3. Removing the discharge temperature thermistor, Photo 12 defrost thermistor, outdoor heat exchanger tem- Outdoor heat Ambient temperature perature thermistor and ambient temperature exchanger temperature thermistor thermistor thermistor (1) Remove the cabinet and panels (refer to section 1). (2) Disconnect the lead wire to the reactor and the following connectors: <Inverter P.C. board> CN641 (Defrost thermistor and discharge temperature thermistor) CN643 (Ambient temperature thermistor) CN644 (Outdoor heat exchanger temperature thermistor) (3) Pull out the discharge temperature thermistor from its holder. (Photo 14) (4) Pull out the defrost thermistor from its holder. (5) Pull out the outdoor heat exchanger temperature therm- istor from its holder. (6) Pull out the ambient temperature thermistor from its holder. Defrost thermistor 4. Removing outdoor fan motor Photo 13 Screws of the outdoor fan motor (1) Remove the cabinet and panels (refer to section 1). (2) Disconnect the following connectors: <Inverter P.C. board> CN931, CN932 (Fan motor) (3) Remove the propeller fan nut. (4) Remove the propeller fan. (5) Remove the screws fixing the fan motor. (6) Remove the fan motor. Propeller fan Propeller fan nut OBD946_65 OPERATING PROCEDURE PHOTOS/FIGURES 5. Removing R. V. coil Photo 14 (1) Remove the cabinet and panels (refer to section 1). Screw of (2) Disconnect the following connectors: the R.V. coil <Inverter P.C. board> CN721 (R.V. coil) Discharge (3) Remove the R.V. coil. temperature thermistor Compressor protector 6. Removing the compressor and 4-way valve (1) Remove the cabinet and panels (refer to section 1). (2) Remove the inverter assembly (refer to section 2). (3) Remove the screws fixing the reactor. (4) Remove the reactor. (5) Remove the soundproof felt. Photo 15 (6) Recover gas from the refrigerant circuit. Discharge pipe NOTE: Recover gas from the pipes until the pressure brazed part gauge shows 0 psig. (7) Detach the brazed part of the suction and the discharge pipe connected with compressor. (8) Remove the compressor nuts. (9) Remove the compressor. (10) Detach the brazed part of pipes connected with 4-way valve. NOTE: If the red labels have been removed during the operation, put them back in the original position after the operation. Red labels indicate the use of flammable refrigerants. (Figure 3) Figure 2 Attach the compressor protector to the protector holder with the Suction pipe Brazed parts of 4-way valve surface on which the brazed part model name is printed facing the area hatched in the figure. Figure 3 Red labels OBD946_66 11-2. MUZ-FX15NLHZ MUZ-FX18NLHZ MUZ-FX24NLHZ NOTE: Turn OFF the power supply before disassembly. OPERATING PROCEDURE PHOTOS/FIGURES 1. Removing the cabinet Photo 2 (1) Remove the screws of the service panel. (2) Remove the screws of the top panel. Screws of (3) Remove the screw of the valve cover. the top panel (4) Remove the service panel. (5) Remove the top panel. (6) Remove the valve cover. (7) Remove the screws fixing the conduit cover. (Photo 5) (8) Remove the conduit cover. (9) Remove the screw fixing the conduit plate. (Photo 6) (10) Remove the conduit plate. (11) Disconnect the power supply and indoor/outdoor con- necting wire. (12) Remove the screws of the cabinet. (13) Remove the cabinet. Screws of the (14) Remove the screws of the back panel. service panel (15) Remove the back panel. Screws of Screw of the the cabinet valve cover NOTE: If the red labels have been removed during the operation, put them back in the original position Photo 3 after the operation. Red labels indicate the use of flammable refrigerants. (Figure 1) Photo 1 Screws of the top panel Direction to remove Screws of Hooks of the the cabinet service panel Photo 4 Screws of the cabinet Figure 1 Screws of the back panel Red label OBD946_67 OPERATING PROCEDURE PHOTOS/FIGURES Photo 5 Screws of the conduit cover Photo 6 Screw of the conduit plate 2. Removing the inverter assembly, inverter P.C. Photo 7 board and fuse P.C. board 2-1. Removing the inverter assembly and inverter P.C. board (1) Remove the top panel, cabinet and service panel. (Refer to section 1.) (2) Disconnect the lead wire to the reactor and the following Screw of the P.C. connectors: board support and <Inverter P.C. board> the motor support CN602 (R.V. coil) CN931, CN932 (Fan motor) CN671 (Defrost thermistor, discharge temperature thermistor and outdoor heat exchanger temper- ature thermistor) CN672 (Ambient temperature thermistor) Screw of the heat CN724 (Expansion valve coil) sink support and CN601 (Defrost heater and heater protector) the separator CN64 (Compressor protector) (3) Remove the compressor connector (CN61). (4) Remove the screws fixing the heat sink support and the Photo 8 (Inverter assembly) separator. Screw of the (5) Remove the screws fixing the P.C. board support and Heat sink support ground wire P.C. board support the motor support. Heat sink (6) Remove the inverter assembly. (7) Remove the screws of the ground wires and the termi- nal block support. (8) Remove the screw of the heat sink support, and the heat sink support from the P.C. board support. Screw of Inverter P.C. board Screws of the the heat sink Fuse P.C. board ground wires and support the terminal block support OBD946_68 OPERATING PROCEDURE PHOTOS/FIGURES * Connection procedure when attaching the inverter Photo 11 P.C. board (Photo 8, 9, 10, 11, 12) Hook of the lead wires of the Hook of the lead 1. Attach the heat sink support to the P.C. board support. P.C. board (red and blue) and wires of the reactor 2. Hook the lead wires of the compressor, the reactor and reactor (white and red) (yellow and blue) the P.C. board to each hooks on the heat sink support as shown in Photo 11. 3. Connect the lead wires of the expansion valve coil to the connector on the inverter P.C. board. Pull the lead wires of the expansion valve coil toward you and put them on the left hook on the P.C. board support as shown in Photo 12. 4. Hook the lead wires of the compressor, fuse P.C. board, discharge temperature thermistor, defrost thermistor and expansion valve coil to each hook and tighten the wires with the fastener as shown in Photo 12. 5. Hook the lead wires of the defrost heater and the heater protector. (Photo 9) Photo 9 Hook of the lead Inverter P.C. board Hooks of the lead wires wires of the of the compressor defrost heater and the heater Photo 12 protector. Lead wires of the Hooks of the lead expansion valve coil wire of the R.V. coil Inverter P.C. board support Hook of the lead wires of the compressor, discharge temperature thermistor, defrost thermistor and the compressor protector Photo 10 Fastener Hook of the lead wires of the reactor Lead wires of the expansion valve coil Screws of the Hook of the lead wires terminal block of the compressor, the support discharge temperature thermistor and the Hook of the lead wire of expansion compressor protector valve coil and defrost thermistor Screws of the ground wires and the terminal block support OBD946_69 OPERATING PROCEDURE PHOTOS/FIGURES 2-2. Removing the fuse P.C. board Photo 13 Support Fuse P.C. board (1) Remove the top panel, cabinet and service panel. (Refer to section 1.) (2) Disconnect the lead wire to the reactor and the inverter P.C. board connectors. (Refer to section 2-1. (2)) (3) Remove the compressor connector (CN61). (4) Remove the screws fixing the heat sink support and the separator. (5) Remove the screws fixing the P.C. board support and the motor support. CN65 CN66 (6) Remove the fixing screws of the terminal block support and the back panel. (7) Remove the inverter assembly. (8) Remove the following disconnected connectors: <Fuse P.C. board> CN65, CN66 (Terminal block) (9) Remove the fuse P.C. board from the supports. Pinch the stopper of the support, and push it into the hole to remove the fuse P.C. board. 3. Removing the discharge temperature thermistor, Photo 14 Outdoor heat exchanger defrost thermistor, outdoor heat exchanger tem- temperature thermistor perature thermistor and ambient temperature thermistor (1) Remove the cabinet and panels. (Refer to section 1.) (2) Disconnect the lead wire to the reactor and the following Ambient connectors: temperature <Inverter P.C. board> thermistor CN671 (Defrost thermistor, discharge temperature thermistor and outdoor heat exchanger temper- ature thermistor) CN672 (Ambient temperature thermistor) (3) Pull out the discharge temperature thermistor from its holder. (Photo 16) (4) Pull out the defrost thermistor from its holder. (5) Pull out the outdoor heat exchanger temperature therm- istor from its holder. (Photo 14) (6) Pull out the ambient temperature thermistor from its Defrost thermistor holder. OBD946_70 OPERATING PROCEDURE PHOTOS/FIGURES 4. Removing outdoor fan motor Photo 15 (1) Remove the top panel, cabinet and service panel. Propeller fan nut (Refer to section 1.) (2) Disconnect the following connectors: <Inverter P.C. board> Propeller fan CN931, CN932 (Fan motor) (3) Remove the propeller fan nut. (4) Remove the propeller fan. (5) Remove the screws fixing the fan motor. (6) Remove the fan motor. Screws of the outdoor fan motor 5. Removing R. V. coil Photo 16 Brazed part of Discharge temperature (1) Remove the cabinet and panels. (Refer to section 1.) the discharge pipe thermistor (2) Disconnect the following connectors: <Inverter P.C. board> CN602 (R.V. coil) (3) Remove the R.V. coil. Screw of the R.V. coil Compressor Brazed part of protector the suction pipe OBD946_71 OPERATING PROCEDURE PHOTOS/FIGURES 6. Removing the compressor and 4-way valve Photo 17 (1) Remove the cabinet and panels. (Refer to section 1.) (2) Remove the inverter assembly. (Refer to section 2.) (3) Remove the screws fixing the reactor. (4) Remove the reactor. (5) Remove the soundproof felt. (6) Recover gas from the refrigerant circuit. NOTE: Recover gas from the pipes until the pressure gauge shows 0 psig. (7) Detach the brazed part of the suction and the discharge Brazed parts of pipe connected with compressor. (Photo 16) 4-way valve (8) Remove the compressor nuts. (9) Remove the compressor. (10) Detach the brazed parts of 4-way valve and pipe. NOTE: If the red labels have been removed during the operation, put them back in the original position after the operation. Red labels indicate the use of flammable refrigerants. (Figure 2) Figure 2 Red labels Figure 3 Attach the compressor protector to the protector holder with the surface on which the model name is printed facing the area hatched in the figure. OBD946_72 12 POSITION OF THE CENTER OF GRAVITY Unit: inch (mm) Model name A B C a b c MUZ-FX06NLHZ 11-1/16 5-9/16 13-3/8 31-1/2 11-1/4 28-1/8 MUZ-FX09NLHZ c (280) (140) (340) (800) (285) (714) MUZ-FX12NLHZ C MUZ-FX15NLHZ 13 5-29/32 15-11/32 33-1/16 13 34-5/8 MUZ-FX18NLHZ (330) (150) (390) (840) (330) (880) MUZ-FX24NLHZ A B a b OBD946_73 13 NOISE CRITERION CURVES MUZ-FX06NLHZ NOTCH SPL(dB(A)) LINE MUZ-FX09NLHZ NOTCH SPL(dB(A)) LINE COOLING 47 COOLING 49 HEATING 48 HEATING 49 90 90 bar)80 bar)80 µ µ 70 70 NC-70 NC-70 60 60 NC-60 NC-60 50 50 NC-50 NC-50 40 40 NC-40 NC-40 30 30 NC-30 NC-30 20 APPROXIMATE 20 APPROXIMATE OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 THRESHOLD OF OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 THRESHOLD OF HEARING FOR NC-20 HEARING FOR NC-20 CONTINUOUS CONTINUOUS 10 NOISE 10 NOISE 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz BAND CENTER FREQUENCIES, Hz MUZ-FX12NLHZ NOTCH SPL(dB(A)) LINE MUZ-FX15NLHZ NOTCH SPL(dB(A)) LINE COOLING 49 COOLING 51 HEATING 51 HEATING 55 90 90 bar)80 bar)80 µ µ 70 70 NC-70 NC-70 60 60 NC-60 NC-60 50 50 NC-50 NC-50 40 40 NC-40 NC-40 30 30 NC-30 NC-30 20 APPROXIMATE 20 APPROXIMATE OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 THRESHOLD OF OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 THRESHOLD OF HEARING FOR NC-20 HEARING FOR NC-20 CONTINUOUS CONTINUOUS 10 NOISE 10 NOISE 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz BAND CENTER FREQUENCIES, Hz RIGHT SIDE VIEW OUTDOOR UNIT 39-3/8 inch (1m) MICROPHONE OBD946_74 MUZ-FX18NLHZ NOTCH SPL(dB(A)) LINE MUZ-FX24NLHZ NOTCH SPL(dB(A)) LINE COOLING 52 COOLING 55 HEATING 55 HEATING 55 90 90 bar)80 bar)80 µ µ 70 70 NC-70 NC-70 60 60 NC-60 NC-60 50 50 NC-50 NC-50 40 40 NC-40 NC-40 30 30 NC-30 NC-30 20 APPROXIMATE 20 APPROXIMATE OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 THRESHOLD OF OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 THRESHOLD OF HEARING FOR NC-20 HEARING FOR NC-20 CONTINUOUS CONTINUOUS 10 NOISE 10 NOISE 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz BAND CENTER FREQUENCIES, Hz RIGHT SIDE VIEW OUTDOOR UNIT 39-3/8 inch (1m) MICROPHONE OBD946_75 14 MAX. HEATING CAPACITY IN LOW AMBIENT TEMPERATURE MUZ-FX06NLHZ 120% 100% 80% 60% 40% % Heating Capacity 20% 0% -10 -5 15 35 55 75 Outdoor Temperature Degrees (°F) HEATING CAPACITY Outdoor Temperature Degrees (°F) -10.0 75.0 % Heating Capacity 100% 100% MUZ-FX09NLHZ 120% 100% 80% 60% 40% % Heating Capacity 20% 0% -10 -5 15 35 55 75 Outdoor Temperature Degrees (°F) HEATING CAPACITY Outdoor Temperature Degrees (°F) -10.0 75.0 % Heating Capacity 100% 100% OBD946_76 MUZ-FX12NLHZ 120% 100% 80% 60% 40% % Heating Capacity 20% 0% -10 -5 15 35 55 75 Outdoor Temperature Degrees (°F) HEATING CAPACITY Outdoor Temperature Degrees (°F) -10.0 75.0 % Heating Capacity 100% 100% MUZ-FX15NLHZ 120% 100% 80% 60% 40% % Heating Capacity 20% 0% -10 -5 15 35 55 75 Outdoor Temperature Degrees (°F) HEATING CAPACITY Outdoor Temperature Degrees (°F) -10.0 75.0 % Heating Capacity 100% 100% OBD946_77 MUZ-FX18NLHZ 120% 100% 80% 60% 40% % Heating Capacity 20% 0% -10 -5 15 35 55 75 Outdoor Temperature Degrees (°F) HEATING CAPACITY Outdoor Temperature Degrees (°F) -10.0 75.0 % Heating Capacity 100% 100% MUZ-FX24NLHZ 120% 100% 80% 60% 40% % Heating Capacity 20% 0% -10 -5 15 35 55 75 Outdoor Temperature Degrees (°F) HEATING CAPACITY Outdoor Temperature Degrees (°F) -10.0 75.0 % Heating Capacity 100% 100% OBD946_78 15 PERFORMANCE CHART 15-1. INVERTER COOLING CAPACITY MUZ-FX06NLHZ CAPACITY (Btu/h): 6000 INPUT (W): 280 SHF: 1.00 OUTDOOR DB (°F) INDOOR INDOOR 70 77 81 86 DB (°F) WB (°F) CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. 70 64 7050 5781 0.82 224 6750 5535 0.82 235 6480 5314 0.82 246 6240 5117 0.82 258 70 68 7350 5145 0.70 235 7050 4935 0.70 249 6840 4788 0.70 255 6600 4620 0.70 266 72 64 7050 6063 0.86 224 6750 5805 0.86 235 6480 5573 0.86 246 6240 5366 0.86 258 72 68 7350 5439 0.74 235 7050 5217 0.74 249 6840 5062 0.74 255 6600 4884 0.74 266 72 72 7650 4743 0.62 244 7380 4576 0.62 259 7200 4464 0.62 266 6900 4278 0.62 277 73 64 7050 6345 0.90 224 6750 6075 0.90 235 6480 5832 0.90 246 6240 5616 0.90 258 73 68 7350 5733 0.78 235 7050 5499 0.78 249 6840 5335 0.78 255 6600 5148 0.78 266 73 72 7650 5049 0.66 244 7380 4871 0.66 259 7200 4752 0.66 266 6900 4554 0.66 277 75 64 7050 6627 0.94 224 6750 6345 0.94 235 6480 6091 0.94 246 6240 5866 0.94 258 75 68 7350 6027 0.82 235 7050 5781 0.82 249 6840 5609 0.82 255 6600 5412 0.82 266 75 72 7650 5355 0.70 244 7380 5166 0.70 259 7200 5040 0.70 266 6900 4830 0.70 277 75 75 8040 4663 0.58 255 7740 4489 0.58 269 7560 4385 0.58 277 7320 4246 0.58 291 77 64 7050 6909 0.98 224 6750 6615 0.98 235 6480 6350 0.98 246 6240 6115 0.98 258 77 68 7350 6321 0.86 235 7050 6063 0.86 249 6840 5882 0.86 255 6600 5676 0.86 266 77 72 7650 5661 0.74 244 7380 5461 0.74 259 7200 5328 0.74 266 6900 5106 0.74 277 77 75 8040 4985 0.62 255 7740 4799 0.62 269 7560 4687 0.62 277 7320 4538 0.62 291 79 64 7050 7050 1.00 224 6750 6750 1.00 235 6480 6480 1.00 246 6240 6240 1.00 258 79 68 7350 6615 0.90 235 7050 6345 0.90 249 6840 6156 0.90 255 6600 5940 0.90 266 79 72 7650 5967 0.78 244 7380 5756 0.78 259 7200 5616 0.78 266 6900 5382 0.78 277 79 75 8040 5306 0.66 255 7740 5108 0.66 269 7560 4990 0.66 277 7320 4831 0.66 291 79 79 8280 4471 0.54 269 8040 4342 0.54 283 7920 4277 0.54 291 7680 4147 0.54 300 81 64 7050 7050 1.00 224 6750 6750 1.00 235 6480 6480 1.00 246 6240 6240 1.00 258 81 68 7350 6909 0.94 235 7050 6627 0.94 249 6840 6430 0.94 255 6600 6204 0.94 266 81 72 7650 6273 0.82 244 7380 6052 0.82 259 7200 5904 0.82 266 6900 5658 0.82 277 81 75 8040 5628 0.70 255 7740 5418 0.70 269 7560 5292 0.70 277 7320 5124 0.70 291 81 79 8280 4802 0.58 269 8040 4663 0.58 283 7920 4594 0.58 291 7680 4454 0.58 300 82 64 7050 7050 1.00 224 6750 6750 1.00 235 6480 6480 1.00 246 6240 6240 1.00 258 82 68 7350 7203 0.98 235 7050 6909 0.98 249 6840 6703 0.98 255 6600 6468 0.98 266 82 72 7650 6579 0.86 244 7380 6347 0.86 259 7200 6192 0.86 266 6900 5934 0.86 277 82 75 8040 5950 0.74 255 7740 5728 0.74 269 7560 5594 0.74 277 7320 5417 0.74 291 82 79 8280 5134 0.62 269 8040 4985 0.62 283 7920 4910 0.62 291 7680 4762 0.62 300 84 64 7050 7050 1.00 224 6750 6750 1.00 235 6480 6480 1.00 246 6240 6240 1.00 258 84 68 7350 7350 1.00 235 7050 7050 1.00 249 6840 6840 1.00 255 6600 6600 1.00 266 84 72 7650 6885 0.90 244 7380 6642 0.90 259 7200 6480 0.90 266 6900 6210 0.90 277 84 75 8040 6271 0.78 255 7740 6037 0.78 269 7560 5897 0.78 277 7320 5710 0.78 291 84 79 8280 5465 0.66 269 8040 5306 0.66 283 7920 5227 0.66 291 7680 5069 0.66 300 86 64 7050 7050 1.00 224 6750 6750 1.00 235 6480 6480 1.00 246 6240 6240 1.00 258 86 68 7350 7350 1.00 235 7050 7050 1.00 249 6840 6840 1.00 255 6600 6600 1.00 266 86 72 7650 7191 0.94 244 7380 6937 0.94 259 7200 6768 0.94 266 6900 6486 0.94 277 86 75 8040 6593 0.82 255 7740 6347 0.82 269 7560 6199 0.82 277 7320 6002 0.82 291 86 79 8280 5796 0.70 269 8040 5628 0.70 283 7920 5544 0.70 291 7680 5376 0.70 300 88 64 7050 7050 1.00 224 6750 6750 1.00 235 6480 6480 1.00 246 6240 6240 1.00 258 88 68 7350 7350 1.00 235 7050 7050 1.00 249 6840 6840 1.00 255 6600 6600 1.00 266 88 72 7650 7497 0.98 244 7380 7232 0.98 259 7200 7056 0.98 266 6900 6762 0.98 277 88 75 8040 6914 0.86 255 7740 6656 0.86 269 7560 6502 0.86 277 7320 6295 0.86 291 88 79 8280 6127 0.74 269 8040 5950 0.74 283 7920 5861 0.74 291 7680 5683 0.74 300 90 64 7050 7050 1.00 224 6750 6750 1.00 235 6480 6480 1.00 246 6240 6240 1.00 258 90 68 7350 7350 1.00 235 7050 7050 1.00 249 6840 6840 1.00 255 6600 6600 1.00 266 90 72 7650 7650 1.00 244 7380 7380 1.00 259 7200 7200 1.00 266 6900 6900 1.00 277 90 75 8040 7236 0.90 255 7740 6966 0.90 269 7560 6804 0.90 277 7320 6588 0.90 291 90 79 8280 6458 0.78 269 8040 6271 0.78 283 7920 6178 0.78 291 7680 5990 0.78 300 NOTE CA: Capacity (Btu/h) SHF: Sensible heat factor DB: Dry-bulb temperature SHC: Sensible heat capacity (Btu/h) P.C. : Power consumption (W) WB: Wet-bulb temperature OBD946_79 MUZ-FX06NLHZ CAPACITY (Btu/h): 6000 INPUT (W): 280 SHF: 1.00 OUTDOOR DB (°F) INDOOR INDOOR 95 104 115 DB (°F) WB (°F) CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. 70 64 5880 4822 0.82 274 5400 4428 0.82 291 4980 4084 0.82 302 70 68 6180 4326 0.70 286 5760 4032 0.70 300 5340 3738 0.70 316 72 64 5880 5057 0.86 274 5400 4644 0.86 291 4980 4283 0.86 302 72 68 6180 4573 0.74 286 5760 4262 0.74 300 5340 3952 0.74 316 72 72 6540 4055 0.62 297 6120 3794 0.62 314 5700 3534 0.62 325 73 64 5880 5292 0.90 274 5400 4860 0.90 291 4980 4482 0.90 302 73 68 6180 4820 0.78 286 5760 4493 0.78 300 5340 4165 0.78 316 73 72 6540 4316 0.66 297 6120 4039 0.66 314 5700 3762 0.66 325 75 64 5880 5527 0.94 274 5400 5076 0.94 291 4980 4681 0.94 302 75 68 6180 5068 0.82 286 5760 4723 0.82 300 5340 4379 0.82 316 75 72 6540 4578 0.70 297 6120 4284 0.70 314 5700 3990 0.70 325 75 75 6900 4002 0.58 308 6480 3758 0.58 322 6120 3550 0.58 336 77 64 5880 5762 0.98 274 5400 5292 0.98 291 4980 4880 0.98 302 77 68 6180 5315 0.86 286 5760 4954 0.86 300 5340 4592 0.86 316 77 72 6540 4840 0.74 297 6120 4529 0.74 314 5700 4218 0.74 325 77 75 6900 4278 0.62 308 6480 4018 0.62 322 6120 3794 0.62 336 79 64 5880 5880 1.00 274 5400 5400 1.00 291 4980 4980 1.00 302 79 68 6180 5562 0.90 286 5760 5184 0.90 300 5340 4806 0.90 316 79 72 6540 5101 0.78 297 6120 4774 0.78 314 5700 4446 0.78 325 79 75 6900 4554 0.66 308 6480 4277 0.66 322 6120 4039 0.66 336 79 79 7260 3920 0.54 319 6840 3694 0.54 333 6420 3467 0.54 347 81 64 5880 5880 1.00 274 5400 5400 1.00 291 4980 4980 1.00 302 81 68 6180 5809 0.94 286 5760 5414 0.94 300 5340 5020 0.94 316 81 72 6540 5363 0.82 297 6120 5018 0.82 314 5700 4674 0.82 325 81 75 6900 4830 0.70 308 6480 4536 0.70 322 6120 4284 0.70 336 81 79 7260 4211 0.58 319 6840 3967 0.58 333 6420 3724 0.58 347 82 64 5880 5880 1.00 274 5400 5400 1.00 291 4980 4980 1.00 302 82 68 6180 6056 0.98 286 5760 5645 0.98 300 5340 5233 0.98 316 82 72 6540 5624 0.86 297 6120 5263 0.86 314 5700 4902 0.86 325 82 75 6900 5106 0.74 308 6480 4795 0.74 322 6120 4529 0.74 336 82 79 7260 4501 0.62 319 6840 4241 0.62 333 6420 3980 0.62 347 84 64 5880 5880 1.00 274 5400 5400 1.00 291 4980 4980 1.00 302 84 68 6180 6180 1.00 286 5760 5760 1.00 300 5340 5340 1.00 316 84 72 6540 5886 0.90 297 6120 5508 0.90 314 5700 5130 0.90 325 84 75 6900 5382 0.78 308 6480 5054 0.78 322 6120 4774 0.78 336 84 79 7260 4792 0.66 319 6840 4514 0.66 333 6420 4237 0.66 347 86 64 5880 5880 1.00 274 5400 5400 1.00 291 4980 4980 1.00 302 86 68 6180 6180 1.00 286 5760 5760 1.00 300 5340 5340 1.00 316 86 72 6540 6148 0.94 297 6120 5753 0.94 314 5700 5358 0.94 325 86 75 6900 5658 0.82 308 6480 5314 0.82 322 6120 5018 0.82 336 86 79 7260 5082 0.70 319 6840 4788 0.70 333 6420 4494 0.70 347 88 64 5880 5880 1.00 274 5400 5400 1.00 291 4980 4980 1.00 302 88 68 6180 6180 1.00 286 5760 5760 1.00 300 5340 5340 1.00 316 88 72 6540 6409 0.98 297 6120 5998 0.98 314 5700 5586 0.98 325 88 75 6900 5934 0.86 308 6480 5573 0.86 322 6120 5263 0.86 336 88 79 7260 5372 0.74 319 6840 5062 0.74 333 6420 4751 0.74 347 90 64 5880 5880 1.00 274 5400 5400 1.00 291 4980 4980 1.00 302 90 68 6180 6180 1.00 286 5760 5760 1.00 300 5340 5340 1.00 316 90 72 6540 6540 1.00 297 6120 6120 1.00 314 5700 5700 1.00 325 90 75 6900 6210 0.90 308 6480 5832 0.90 322 6120 5508 0.90 336 90 79 7260 5663 0.78 319 6840 5335 0.78 333 6420 5008 0.78 347 NOTE CA: Capacity (Btu/h) SHF: Sensible heat factor DB: Dry-bulb temperature SHC: Sensible heat capacity (Btu/h) P.C. : Power consumption (W) WB: Wet-bulb temperature OBD946_80 MUZ-FX09NLHZ CAPACITY (Btu/h): 9000 INPUT (W): 490 SHF: 1.00 OUTDOOR DB (°F) INDOOR INDOOR 70 77 81 86 DB (°F) WB (°F) CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. 70 64 10575 8672 0.82 392 10125 8303 0.82 412 9720 7970 0.82 431 9360 7675 0.82 451 70 68 11025 7718 0.70 412 10575 7403 0.70 436 10260 7182 0.70 446 9900 6930 0.70 466 72 64 10575 9095 0.86 392 10125 8708 0.86 412 9720 8359 0.86 431 9360 8050 0.86 451 72 68 11025 8159 0.74 412 10575 7826 0.74 436 10260 7592 0.74 446 9900 7326 0.74 466 72 72 11475 7115 0.62 426 11070 6863 0.62 453 10800 6696 0.62 466 10350 6417 0.62 485 73 64 10575 9518 0.90 392 10125 9113 0.90 412 9720 8748 0.90 431 9360 8424 0.90 451 73 68 11025 8600 0.78 412 10575 8249 0.78 436 10260 8003 0.78 446 9900 7722 0.78 466 73 72 11475 7574 0.66 426 11070 7306 0.66 453 10800 7128 0.66 466 10350 6831 0.66 485 75 64 10575 9941 0.94 392 10125 9518 0.94 412 9720 9137 0.94 431 9360 8798 0.94 451 75 68 11025 9041 0.82 412 10575 8672 0.82 436 10260 8413 0.82 446 9900 8118 0.82 466 75 72 11475 8033 0.70 426 11070 7749 0.70 453 10800 7560 0.70 466 10350 7245 0.70 485 75 75 12060 6995 0.58 446 11610 6734 0.58 470 11340 6577 0.58 485 10980 6368 0.58 510 77 64 10575 10364 0.98 392 10125 9923 0.98 412 9720 9526 0.98 431 9360 9173 0.98 451 77 68 11025 9482 0.86 412 10575 9095 0.86 436 10260 8824 0.86 446 9900 8514 0.86 466 77 72 11475 8492 0.74 426 11070 8192 0.74 453 10800 7992 0.74 466 10350 7659 0.74 485 77 75 12060 7477 0.62 446 11610 7198 0.62 470 11340 7031 0.62 485 10980 6808 0.62 510 79 64 10575 10575 1.00 392 10125 10125 1.00 412 9720 9720 1.00 431 9360 9360 1.00 451 79 68 11025 9923 0.90 412 10575 9518 0.90 436 10260 9234 0.90 446 9900 8910 0.90 466 79 72 11475 8951 0.78 426 11070 8635 0.78 453 10800 8424 0.78 466 10350 8073 0.78 485 79 75 12060 7960 0.66 446 11610 7663 0.66 470 11340 7484 0.66 485 10980 7247 0.66 510 79 79 12420 6707 0.54 470 12060 6512 0.54 495 11880 6415 0.54 510 11520 6221 0.54 524 81 64 10575 10575 1.00 392 10125 10125 1.00 412 9720 9720 1.00 431 9360 9360 1.00 451 81 68 11025 10364 0.94 412 10575 9941 0.94 436 10260 9644 0.94 446 9900 9306 0.94 466 81 72 11475 9410 0.82 426 11070 9077 0.82 453 10800 8856 0.82 466 10350 8487 0.82 485 81 75 12060 8442 0.70 446 11610 8127 0.70 470 11340 7938 0.70 485 10980 7686 0.70 510 81 79 12420 7204 0.58 470 12060 6995 0.58 495 11880 6890 0.58 510 11520 6682 0.58 524 82 64 10575 10575 1.00 392 10125 10125 1.00 412 9720 9720 1.00 431 9360 9360 1.00 451 82 68 11025 10805 0.98 412 10575 10364 0.98 436 10260 10055 0.98 446 9900 9702 0.98 466 82 72 11475 9869 0.86 426 11070 9520 0.86 453 10800 9288 0.86 466 10350 8901 0.86 485 82 75 12060 8924 0.74 446 11610 8591 0.74 470 11340 8392 0.74 485 10980 8125 0.74 510 82 79 12420 7700 0.62 470 12060 7477 0.62 495 11880 7366 0.62 510 11520 7142 0.62 524 84 64 10575 10575 1.00 392 10125 10125 1.00 412 9720 9720 1.00 431 9360 9360 1.00 451 84 68 11025 11025 1.00 412 10575 10575 1.00 436 10260 10260 1.00 446 9900 9900 1.00 466 84 72 11475 10328 0.90 426 11070 9963 0.90 453 10800 9720 0.90 466 10350 9315 0.90 485 84 75 12060 9407 0.78 446 11610 9056 0.78 470 11340 8845 0.78 485 10980 8564 0.78 510 84 79 12420 8197 0.66 470 12060 7960 0.66 495 11880 7841 0.66 510 11520 7603 0.66 524 86 64 10575 10575 1.00 392 10125 10125 1.00 412 9720 9720 1.00 431 9360 9360 1.00 451 86 68 11025 11025 1.00 412 10575 10575 1.00 436 10260 10260 1.00 446 9900 9900 1.00 466 86 72 11475 10787 0.94 426 11070 10406 0.94 453 10800 10152 0.94 466 10350 9729 0.94 485 86 75 12060 9889 0.82 446 11610 9520 0.82 470 11340 9299 0.82 485 10980 9004 0.82 510 86 79 12420 8694 0.70 470 12060 8442 0.70 495 11880 8316 0.70 510 11520 8064 0.70 524 88 64 10575 10575 1.00 392 10125 10125 1.00 412 9720 9720 1.00 431 9360 9360 1.00 451 88 68 11025 11025 1.00 412 10575 10575 1.00 436 10260 10260 1.00 446 9900 9900 1.00 466 88 72 11475 11246 0.98 426 11070 10849 0.98 453 10800 10584 0.98 466 10350 10143 0.98 485 88 75 12060 10372 0.86 446 11610 9985 0.86 470 11340 9752 0.86 485 10980 9443 0.86 510 88 79 12420 9191 0.74 470 12060 8924 0.74 495 11880 8791 0.74 510 11520 8525 0.74 524 90 64 10575 10575 1.00 392 10125 10125 1.00 412 9720 9720 1.00 431 9360 9360 1.00 451 90 68 11025 11025 1.00 412 10575 10575 1.00 436 10260 10260 1.00 446 9900 9900 1.00 466 90 72 11475 11475 1.00 426 11070 11070 1.00 453 10800 10800 1.00 466 10350 10350 1.00 485 90 75 12060 10854 0.90 446 11610 10449 0.90 470 11340 10206 0.90 485 10980 9882 0.90 510 90 79 12420 9688 0.78 470 12060 9407 0.78 495 11880 9266 0.78 510 11520 8986 0.78 524 NOTE CA: Capacity (Btu/h) SHF: Sensible heat factor DB: Dry-bulb temperature SHC: Sensible heat capacity (Btu/h) P.C. : Power consumption (W) WB: Wet-bulb temperature OBD946_81 MUZ-FX09NLHZ CAPACITY (Btu/h): 9000 INPUT (W): 490 SHF: 1.00 OUTDOOR DB (°F) INDOOR INDOOR 95 104 115 DB (°F) WB (°F) CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. 70 64 8820 7232 0.82 480 8100 6642 0.82 510 7470 6125 0.82 529 70 68 9270 6489 0.70 500 8640 6048 0.70 524 8010 5607 0.70 554 72 64 8820 7585 0.86 480 8100 6966 0.86 510 7470 6424 0.86 529 72 68 9270 6860 0.74 500 8640 6394 0.74 524 8010 5927 0.74 554 72 72 9810 6082 0.62 519 9180 5692 0.62 549 8550 5301 0.62 568 73 64 8820 7938 0.90 480 8100 7290 0.90 510 7470 6723 0.90 529 73 68 9270 7231 0.78 500 8640 6739 0.78 524 8010 6248 0.78 554 73 72 9810 6475 0.66 519 9180 6059 0.66 549 8550 5643 0.66 568 75 64 8820 8291 0.94 480 8100 7614 0.94 510 7470 7022 0.94 529 75 68 9270 7601 0.82 500 8640 7085 0.82 524 8010 6568 0.82 554 75 72 9810 6867 0.70 519 9180 6426 0.70 549 8550 5985 0.70 568 75 75 10350 6003 0.58 539 9720 5638 0.58 564 9180 5324 0.58 588 77 64 8820 8644 0.98 480 8100 7938 0.98 510 7470 7321 0.98 529 77 68 9270 7972 0.86 500 8640 7430 0.86 524 8010 6889 0.86 554 77 72 9810 7259 0.74 519 9180 6793 0.74 549 8550 6327 0.74 568 77 75 10350 6417 0.62 539 9720 6026 0.62 564 9180 5692 0.62 588 79 64 8820 8820 1.00 480 8100 8100 1.00 510 7470 7470 1.00 529 79 68 9270 8343 0.90 500 8640 7776 0.90 524 8010 7209 0.90 554 79 72 9810 7652 0.78 519 9180 7160 0.78 549 8550 6669 0.78 568 79 75 10350 6831 0.66 539 9720 6415 0.66 564 9180 6059 0.66 588 79 79 10890 5881 0.54 559 10260 5540 0.54 583 9630 5200 0.54 608 81 64 8820 8820 1.00 480 8100 8100 1.00 510 7470 7470 1.00 529 81 68 9270 8714 0.94 500 8640 8122 0.94 524 8010 7529 0.94 554 81 72 9810 8044 0.82 519 9180 7528 0.82 549 8550 7011 0.82 568 81 75 10350 7245 0.70 539 9720 6804 0.70 564 9180 6426 0.70 588 81 79 10890 6316 0.58 559 10260 5951 0.58 583 9630 5585 0.58 608 82 64 8820 8820 1.00 480 8100 8100 1.00 510 7470 7470 1.00 529 82 68 9270 9085 0.98 500 8640 8467 0.98 524 8010 7850 0.98 554 82 72 9810 8437 0.86 519 9180 7895 0.86 549 8550 7353 0.86 568 82 75 10350 7659 0.74 539 9720 7193 0.74 564 9180 6793 0.74 588 82 79 10890 6752 0.62 559 10260 6361 0.62 583 9630 5971 0.62 608 84 64 8820 8820 1.00 480 8100 8100 1.00 510 7470 7470 1.00 529 84 68 9270 9270 1.00 500 8640 8640 1.00 524 8010 8010 1.00 554 84 72 9810 8829 0.90 519 9180 8262 0.90 549 8550 7695 0.90 568 84 75 10350 8073 0.78 539 9720 7582 0.78 564 9180 7160 0.78 588 84 79 10890 7187 0.66 559 10260 6772 0.66 583 9630 6356 0.66 608 86 64 8820 8820 1.00 480 8100 8100 1.00 510 7470 7470 1.00 529 86 68 9270 9270 1.00 500 8640 8640 1.00 524 8010 8010 1.00 554 86 72 9810 9221 0.94 519 9180 8629 0.94 549 8550 8037 0.94 568 86 75 10350 8487 0.82 539 9720 7970 0.82 564 9180 7528 0.82 588 86 79 10890 7623 0.70 559 10260 7182 0.70 583 9630 6741 0.70 608 88 64 8820 8820 1.00 480 8100 8100 1.00 510 7470 7470 1.00 529 88 68 9270 9270 1.00 500 8640 8640 1.00 524 8010 8010 1.00 554 88 72 9810 9614 0.98 519 9180 8996 0.98 549 8550 8379 0.98 568 88 75 10350 8901 0.86 539 9720 8359 0.86 564 9180 7895 0.86 588 88 79 10890 8059 0.74 559 10260 7592 0.74 583 9630 7126 0.74 608 90 64 8820 8820 1.00 480 8100 8100 1.00 510 7470 7470 1.00 529 90 68 9270 9270 1.00 500 8640 8640 1.00 524 8010 8010 1.00 554 90 72 9810 9810 1.00 519 9180 9180 1.00 549 8550 8550 1.00 568 90 75 10350 9315 0.90 539 9720 8748 0.90 564 9180 8262 0.90 588 90 79 10890 8494 0.78 559 10260 8003 0.78 583 9630 7511 0.78 608 NOTE CA: Capacity (Btu/h) SHF: Sensible heat factor DB: Dry-bulb temperature SHC: Sensible heat capacity (Btu/h) P.C. : Power consumption (W) WB: Wet-bulb temperature OBD946_82 MUZ-FX12NLHZ CAPACITY (Btu/h): 12000 INPUT (W): 780 SHF: 0.88 OUTDOOR DB (°F) INDOOR INDOOR 70 77 81 86 DB (°F) WB (°F) CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. 70 64 14100 9870 0.70 624 13500 9450 0.70 655 12960 9072 0.70 686 12480 8736 0.70 718 70 68 14700 8526 0.58 655 14100 8178 0.58 694 13680 7934 0.58 710 13200 7656 0.58 741 72 64 14100 10434 0.74 624 13500 9990 0.74 655 12960 9590 0.74 686 12480 9235 0.74 718 72 68 14700 9114 0.62 655 14100 8742 0.62 694 13680 8482 0.62 710 13200 8184 0.62 741 72 72 15300 7650 0.50 679 14760 7380 0.50 722 14400 7200 0.50 741 13800 6900 0.50 772 73 64 14100 10998 0.78 624 13500 10530 0.78 655 12960 10109 0.78 686 12480 9734 0.78 718 73 68 14700 9702 0.66 655 14100 9306 0.66 694 13680 9029 0.66 710 13200 8712 0.66 741 73 72 15300 8262 0.54 679 14760 7970 0.54 722 14400 7776 0.54 741 13800 7452 0.54 772 75 64 14100 11562 0.82 624 13500 11070 0.82 655 12960 10627 0.82 686 12480 10234 0.82 718 75 68 14700 10290 0.70 655 14100 9870 0.70 694 13680 9576 0.70 710 13200 9240 0.70 741 75 72 15300 8874 0.58 679 14760 8561 0.58 722 14400 8352 0.58 741 13800 8004 0.58 772 75 75 16080 7397 0.46 710 15480 7121 0.46 749 15120 6955 0.46 772 14640 6734 0.46 811 77 64 14100 12126 0.86 624 13500 11610 0.86 655 12960 11146 0.86 686 12480 10733 0.86 718 77 68 14700 10878 0.74 655 14100 10434 0.74 694 13680 10123 0.74 710 13200 9768 0.74 741 77 72 15300 9486 0.62 679 14760 9151 0.62 722 14400 8928 0.62 741 13800 8556 0.62 772 77 75 16080 8040 0.50 710 15480 7740 0.50 749 15120 7560 0.50 772 14640 7320 0.50 811 79 64 14100 12690 0.90 624 13500 12150 0.90 655 12960 11664 0.90 686 12480 11232 0.90 718 79 68 14700 11466 0.78 655 14100 10998 0.78 694 13680 10670 0.78 710 13200 10296 0.78 741 79 72 15300 10098 0.66 679 14760 9742 0.66 722 14400 9504 0.66 741 13800 9108 0.66 772 79 75 16080 8683 0.54 710 15480 8359 0.54 749 15120 8165 0.54 772 14640 7906 0.54 811 79 79 16560 6955 0.42 749 16080 6754 0.42 788 15840 6653 0.42 811 15360 6451 0.42 835 81 64 14100 13254 0.94 624 13500 12690 0.94 655 12960 12182 0.94 686 12480 11731 0.94 718 81 68 14700 12054 0.82 655 14100 11562 0.82 694 13680 11218 0.82 710 13200 10824 0.82 741 81 72 15300 10710 0.70 679 14760 10332 0.70 722 14400 10080 0.70 741 13800 9660 0.70 772 81 75 16080 9326 0.58 710 15480 8978 0.58 749 15120 8770 0.58 772 14640 8491 0.58 811 81 79 16560 7618 0.46 749 16080 7397 0.46 788 15840 7286 0.46 811 15360 7066 0.46 835 82 64 14100 13818 0.98 624 13500 13230 0.98 655 12960 12701 0.98 686 12480 12230 0.98 718 82 68 14700 12642 0.86 655 14100 12126 0.86 694 13680 11765 0.86 710 13200 11352 0.86 741 82 72 15300 11322 0.74 679 14760 10922 0.74 722 14400 10656 0.74 741 13800 10212 0.74 772 82 75 16080 9970 0.62 710 15480 9598 0.62 749 15120 9374 0.62 772 14640 9077 0.62 811 82 79 16560 8280 0.50 749 16080 8040 0.50 788 15840 7920 0.50 811 15360 7680 0.50 835 84 64 14100 14100 1.00 624 13500 13500 1.00 655 12960 12960 1.00 686 12480 12480 1.00 718 84 68 14700 13230 0.90 655 14100 12690 0.90 694 13680 12312 0.90 710 13200 11880 0.90 741 84 72 15300 11934 0.78 679 14760 11513 0.78 722 14400 11232 0.78 741 13800 10764 0.78 772 84 75 16080 10613 0.66 710 15480 10217 0.66 749 15120 9979 0.66 772 14640 9662 0.66 811 84 79 16560 8942 0.54 749 16080 8683 0.54 788 15840 8554 0.54 811 15360 8294 0.54 835 86 64 14100 14100 1.00 624 13500 13500 1.00 655 12960 12960 1.00 686 12480 12480 1.00 718 86 68 14700 13818 0.94 655 14100 13254 0.94 694 13680 12859 0.94 710 13200 12408 0.94 741 86 72 15300 12546 0.82 679 14760 12103 0.82 722 14400 11808 0.82 741 13800 11316 0.82 772 86 75 16080 11256 0.70 710 15480 10836 0.70 749 15120 10584 0.70 772 14640 10248 0.70 811 86 79 16560 9605 0.58 749 16080 9326 0.58 788 15840 9187 0.58 811 15360 8909 0.58 835 88 64 14100 14100 1.00 624 13500 13500 1.00 655 12960 12960 1.00 686 12480 12480 1.00 718 88 68 14700 14406 0.98 655 14100 13818 0.98 694 13680 13406 0.98 710 13200 12936 0.98 741 88 72 15300 13158 0.86 679 14760 12694 0.86 722 14400 12384 0.86 741 13800 11868 0.86 772 88 75 16080 11899 0.74 710 15480 11455 0.74 749 15120 11189 0.74 772 14640 10834 0.74 811 88 79 16560 10267 0.62 749 16080 9970 0.62 788 15840 9821 0.62 811 15360 9523 0.62 835 90 64 14100 14100 1.00 624 13500 13500 1.00 655 12960 12960 1.00 686 12480 12480 1.00 718 90 68 14700 14700 1.00 655 14100 14100 1.00 694 13680 13680 1.00 710 13200 13200 1.00 741 90 72 15300 13770 0.90 679 14760 13284 0.90 722 14400 12960 0.90 741 13800 12420 0.90 772 90 75 16080 12542 0.78 710 15480 12074 0.78 749 15120 11794 0.78 772 14640 11419 0.78 811 90 79 16560 10930 0.66 749 16080 10613 0.66 788 15840 10454 0.66 811 15360 10138 0.66 835 NOTE CA: Capacity (Btu/h) SHF: Sensible heat factor DB: Dry-bulb temperature SHC: Sensible heat capacity (Btu/h) P.C. : Power consumption (W) WB: Wet-bulb temperature OBD946_83 MUZ-FX12NLHZ CAPACITY (Btu/h): 12000 INPUT (W): 780 SHF: 0.88 OUTDOOR DB (°F) INDOOR INDOOR 95 104 115 DB (°F) WB (°F) CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. 70 64 11760 8232 0.70 764 10800 7560 0.70 811 9960 6972 0.70 842 70 68 12360 7169 0.58 796 11520 6682 0.58 835 10680 6194 0.58 881 72 64 11760 8702 0.74 764 10800 7992 0.74 811 9960 7370 0.74 842 72 68 12360 7663 0.62 796 11520 7142 0.62 835 10680 6622 0.62 881 72 72 13080 6540 0.50 827 12240 6120 0.50 874 11400 5700 0.50 905 73 64 11760 9173 0.78 764 10800 8424 0.78 811 9960 7769 0.78 842 73 68 12360 8158 0.66 796 11520 7603 0.66 835 10680 7049 0.66 881 73 72 13080 7063 0.54 827 12240 6610 0.54 874 11400 6156 0.54 905 75 64 11760 9643 0.82 764 10800 8856 0.82 811 9960 8167 0.82 842 75 68 12360 8652 0.70 796 11520 8064 0.70 835 10680 7476 0.70 881 75 72 13080 7586 0.58 827 12240 7099 0.58 874 11400 6612 0.58 905 75 75 13800 6348 0.46 858 12960 5962 0.46 897 12240 5630 0.46 936 77 64 11760 10114 0.86 764 10800 9288 0.86 811 9960 8566 0.86 842 77 68 12360 9146 0.74 796 11520 8525 0.74 835 10680 7903 0.74 881 77 72 13080 8110 0.62 827 12240 7589 0.62 874 11400 7068 0.62 905 77 75 13800 6900 0.50 858 12960 6480 0.50 897 12240 6120 0.50 936 79 64 11760 10584 0.90 764 10800 9720 0.90 811 9960 8964 0.90 842 79 68 12360 9641 0.78 796 11520 8986 0.78 835 10680 8330 0.78 881 79 72 13080 8633 0.66 827 12240 8078 0.66 874 11400 7524 0.66 905 79 75 13800 7452 0.54 858 12960 6998 0.54 897 12240 6610 0.54 936 79 79 14520 6098 0.42 889 13680 5746 0.42 928 12840 5393 0.42 967 81 64 11760 11054 0.94 764 10800 10152 0.94 811 9960 9362 0.94 842 81 68 12360 10135 0.82 796 11520 9446 0.82 835 10680 8758 0.82 881 81 72 13080 9156 0.70 827 12240 8568 0.70 874 11400 7980 0.70 905 81 75 13800 8004 0.58 858 12960 7517 0.58 897 12240 7099 0.58 936 81 79 14520 6679 0.46 889 13680 6293 0.46 928 12840 5906 0.46 967 82 64 11760 11525 0.98 764 10800 10584 0.98 811 9960 9761 0.98 842 82 68 12360 10630 0.86 796 11520 9907 0.86 835 10680 9185 0.86 881 82 72 13080 9679 0.74 827 12240 9058 0.74 874 11400 8436 0.74 905 82 75 13800 8556 0.62 858 12960 8035 0.62 897 12240 7589 0.62 936 82 79 14520 7260 0.50 889 13680 6840 0.50 928 12840 6420 0.50 967 84 64 11760 11760 1.00 764 10800 10800 1.00 811 9960 9960 1.00 842 84 68 12360 11124 0.90 796 11520 10368 0.90 835 10680 9612 0.90 881 84 72 13080 10202 0.78 827 12240 9547 0.78 874 11400 8892 0.78 905 84 75 13800 9108 0.66 858 12960 8554 0.66 897 12240 8078 0.66 936 84 79 14520 7841 0.54 889 13680 7387 0.54 928 12840 6934 0.54 967 86 64 11760 11760 1.00 764 10800 10800 1.00 811 9960 9960 1.00 842 86 68 12360 11618 0.94 796 11520 10829 0.94 835 10680 10039 0.94 881 86 72 13080 10726 0.82 827 12240 10037 0.82 874 11400 9348 0.82 905 86 75 13800 9660 0.70 858 12960 9072 0.70 897 12240 8568 0.70 936 86 79 14520 8422 0.58 889 13680 7934 0.58 928 12840 7447 0.58 967 88 64 11760 11760 1.00 764 10800 10800 1.00 811 9960 9960 1.00 842 88 68 12360 12113 0.98 796 11520 11290 0.98 835 10680 10466 0.98 881 88 72 13080 11249 0.86 827 12240 10526 0.86 874 11400 9804 0.86 905 88 75 13800 10212 0.74 858 12960 9590 0.74 897 12240 9058 0.74 936 88 79 14520 9002 0.62 889 13680 8482 0.62 928 12840 7961 0.62 967 90 64 11760 11760 1.00 764 10800 10800 1.00 811 9960 9960 1.00 842 90 68 12360 12360 1.00 796 11520 11520 1.00 835 10680 10680 1.00 881 90 72 13080 11772 0.90 827 12240 11016 0.90 874 11400 10260 0.90 905 90 75 13800 10764 0.78 858 12960 10109 0.78 897 12240 9547 0.78 936 90 79 14520 9583 0.66 889 13680 9029 0.66 928 12840 8474 0.66 967 NOTE CA: Capacity (Btu/h) SHF: Sensible heat factor DB: Dry-bulb temperature SHC: Sensible heat capacity (Btu/h) P.C. : Power consumption (W) WB: Wet-bulb temperature OBD946_84 MUZ-FX15NLHZ CAPACITY (Btu/h): 15000 INPUT (W): 1020 SHF: 0.81 OUTDOOR DB (°F) INDOOR INDOOR 70 77 81 86 DB (°F) WB (°F) CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. 70 64 17625 11104 0.63 816 16875 10631 0.63 857 16200 10206 0.63 898 15600 9828 0.63 938 70 68 18375 9371 0.51 857 17625 8989 0.51 908 17100 8721 0.51 928 16500 8415 0.51 969 72 64 17625 11809 0.67 816 16875 11306 0.67 857 16200 10854 0.67 898 15600 10452 0.67 938 72 68 18375 10106 0.55 857 17625 9694 0.55 908 17100 9405 0.55 928 16500 9075 0.55 969 72 72 19125 8224 0.43 887 18450 7934 0.43 944 18000 7740 0.43 969 17250 7418 0.43 1010 73 64 17625 12514 0.71 816 16875 11981 0.71 857 16200 11502 0.71 898 15600 11076 0.71 938 73 68 18375 10841 0.59 857 17625 10399 0.59 908 17100 10089 0.59 928 16500 9735 0.59 969 73 72 19125 8989 0.47 887 18450 8672 0.47 944 18000 8460 0.47 969 17250 8108 0.47 1010 75 64 17625 13219 0.75 816 16875 12656 0.75 857 16200 12150 0.75 898 15600 11700 0.75 938 75 68 18375 11576 0.63 857 17625 11104 0.63 908 17100 10773 0.63 928 16500 10395 0.63 969 75 72 19125 9754 0.51 887 18450 9410 0.51 944 18000 9180 0.51 969 17250 8798 0.51 1010 75 75 20100 7839 0.39 928 19350 7547 0.39 979 18900 7371 0.39 1010 18300 7137 0.39 1061 77 64 17625 13924 0.79 816 16875 13331 0.79 857 16200 12798 0.79 898 15600 12324 0.79 938 77 68 18375 12311 0.67 857 17625 11809 0.67 908 17100 11457 0.67 928 16500 11055 0.67 969 77 72 19125 10519 0.55 887 18450 10148 0.55 944 18000 9900 0.55 969 17250 9488 0.55 1010 77 75 20100 8643 0.43 928 19350 8321 0.43 979 18900 8127 0.43 1010 18300 7869 0.43 1061 79 64 17625 14629 0.83 816 16875 14006 0.83 857 16200 13446 0.83 898 15600 12948 0.83 938 79 68 18375 13046 0.71 857 17625 12514 0.71 908 17100 12141 0.71 928 16500 11715 0.71 969 79 72 19125 11284 0.59 887 18450 10886 0.59 944 18000 10620 0.59 969 17250 10178 0.59 1010 79 75 20100 9447 0.47 928 19350 9095 0.47 979 18900 8883 0.47 1010 18300 8601 0.47 1061 79 79 20700 7245 0.35 979 20100 7035 0.35 1030 19800 6930 0.35 1061 19200 6720 0.35 1091 81 64 17625 15334 0.87 816 16875 14681 0.87 857 16200 14094 0.87 898 15600 13572 0.87 938 81 68 18375 13781 0.75 857 17625 13219 0.75 908 17100 12825 0.75 928 16500 12375 0.75 969 81 72 19125 12049 0.63 887 18450 11624 0.63 944 18000 11340 0.63 969 17250 10868 0.63 1010 81 75 20100 10251 0.51 928 19350 9869 0.51 979 18900 9639 0.51 1010 18300 9333 0.51 1061 81 79 20700 8073 0.39 979 20100 7839 0.39 1030 19800 7722 0.39 1061 19200 7488 0.39 1091 82 64 17625 16039 0.91 816 16875 15356 0.91 857 16200 14742 0.91 898 15600 14196 0.91 938 82 68 18375 14516 0.79 857 17625 13924 0.79 908 17100 13509 0.79 928 16500 13035 0.79 969 82 72 19125 12814 0.67 887 18450 12362 0.67 944 18000 12060 0.67 969 17250 11558 0.67 1010 82 75 20100 11055 0.55 928 19350 10643 0.55 979 18900 10395 0.55 1010 18300 10065 0.55 1061 82 79 20700 8901 0.43 979 20100 8643 0.43 1030 19800 8514 0.43 1061 19200 8256 0.43 1091 84 64 17625 16744 0.95 816 16875 16031 0.95 857 16200 15390 0.95 898 15600 14820 0.95 938 84 68 18375 15251 0.83 857 17625 14629 0.83 908 17100 14193 0.83 928 16500 13695 0.83 969 84 72 19125 13579 0.71 887 18450 13100 0.71 944 18000 12780 0.71 969 17250 12248 0.71 1010 84 75 20100 11859 0.59 928 19350 11417 0.59 979 18900 11151 0.59 1010 18300 10797 0.59 1061 84 79 20700 9729 0.47 979 20100 9447 0.47 1030 19800 9306 0.47 1061 19200 9024 0.47 1091 86 64 17625 17449 0.99 816 16875 16706 0.99 857 16200 16038 0.99 898 15600 15444 0.99 938 86 68 18375 15986 0.87 857 17625 15334 0.87 908 17100 14877 0.87 928 16500 14355 0.87 969 86 72 19125 14344 0.75 887 18450 13838 0.75 944 18000 13500 0.75 969 17250 12938 0.75 1010 86 75 20100 12663 0.63 928 19350 12191 0.63 979 18900 11907 0.63 1010 18300 11529 0.63 1061 86 79 20700 10557 0.51 979 20100 10251 0.51 1030 19800 10098 0.51 1061 19200 9792 0.51 1091 88 64 17625 17625 1.00 816 16875 16875 1.00 857 16200 16200 1.00 898 15600 15600 1.00 938 88 68 18375 16721 0.91 857 17625 16039 0.91 908 17100 15561 0.91 928 16500 15015 0.91 969 88 72 19125 15109 0.79 887 18450 14576 0.79 944 18000 14220 0.79 969 17250 13628 0.79 1010 88 75 20100 13467 0.67 928 19350 12965 0.67 979 18900 12663 0.67 1010 18300 12261 0.67 1061 88 79 20700 11385 0.55 979 20100 11055 0.55 1030 19800 10890 0.55 1061 19200 10560 0.55 1091 90 64 17625 17625 1.00 816 16875 16875 1.00 857 16200 16200 1.00 898 15600 15600 1.00 938 90 68 18375 17456 0.95 857 17625 16744 0.95 908 17100 16245 0.95 928 16500 15675 0.95 969 90 72 19125 15874 0.83 887 18450 15314 0.83 944 18000 14940 0.83 969 17250 14318 0.83 1010 90 75 20100 14271 0.71 928 19350 13739 0.71 979 18900 13419 0.71 1010 18300 12993 0.71 1061 90 79 20700 12213 0.59 979 20100 11859 0.59 1030 19800 11682 0.59 1061 19200 11328 0.59 1091 NOTE CA: Capacity (Btu/h) SHF: Sensible heat factor DB: Dry-bulb temperature SHC: Sensible heat capacity (Btu/h) P.C. : Power consumption (W) WB: Wet-bulb temperature OBD946_85 MUZ-FX15NLHZ CAPACITY (Btu/h): 15000 INPUT (W): 1020 SHF: 0.81 OUTDOOR DB (°F) INDOOR INDOOR 95 104 115 DB (°F) WB (°F) CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. 70 64 14700 9261 0.63 1000 13500 8505 0.63 1061 12450 7844 0.63 1102 70 68 15450 7880 0.51 1040 14400 7344 0.51 1091 13350 6809 0.51 1153 72 64 14700 9849 0.67 1000 13500 9045 0.67 1061 12450 8342 0.67 1102 72 68 15450 8498 0.55 1040 14400 7920 0.55 1091 13350 7343 0.55 1153 72 72 16350 7031 0.43 1081 15300 6579 0.43 1142 14250 6128 0.43 1183 73 64 14700 10437 0.71 1000 13500 9585 0.71 1061 12450 8840 0.71 1102 73 68 15450 9116 0.59 1040 14400 8496 0.59 1091 13350 7877 0.59 1153 73 72 16350 7685 0.47 1081 15300 7191 0.47 1142 14250 6698 0.47 1183 75 64 14700 11025 0.75 1000 13500 10125 0.75 1061 12450 9338 0.75 1102 75 68 15450 9734 0.63 1040 14400 9072 0.63 1091 13350 8411 0.63 1153 75 72 16350 8339 0.51 1081 15300 7803 0.51 1142 14250 7268 0.51 1183 75 75 17250 6728 0.39 1122 16200 6318 0.39 1173 15300 5967 0.39 1224 77 64 14700 11613 0.79 1000 13500 10665 0.79 1061 12450 9836 0.79 1102 77 68 15450 10352 0.67 1040 14400 9648 0.67 1091 13350 8945 0.67 1153 77 72 16350 8993 0.55 1081 15300 8415 0.55 1142 14250 7838 0.55 1183 77 75 17250 7418 0.43 1122 16200 6966 0.43 1173 15300 6579 0.43 1224 79 64 14700 12201 0.83 1000 13500 11205 0.83 1061 12450 10334 0.83 1102 79 68 15450 10970 0.71 1040 14400 10224 0.71 1091 13350 9479 0.71 1153 79 72 16350 9647 0.59 1081 15300 9027 0.59 1142 14250 8408 0.59 1183 79 75 17250 8108 0.47 1122 16200 7614 0.47 1173 15300 7191 0.47 1224 79 79 18150 6353 0.35 1163 17100 5985 0.35 1214 16050 5618 0.35 1265 81 64 14700 12789 0.87 1000 13500 11745 0.87 1061 12450 10832 0.87 1102 81 68 15450 11588 0.75 1040 14400 10800 0.75 1091 13350 10013 0.75 1153 81 72 16350 10301 0.63 1081 15300 9639 0.63 1142 14250 8978 0.63 1183 81 75 17250 8798 0.51 1122 16200 8262 0.51 1173 15300 7803 0.51 1224 81 79 18150 7079 0.39 1163 17100 6669 0.39 1214 16050 6260 0.39 1265 82 64 14700 13377 0.91 1000 13500 12285 0.91 1061 12450 11330 0.91 1102 82 68 15450 12206 0.79 1040 14400 11376 0.79 1091 13350 10547 0.79 1153 82 72 16350 10955 0.67 1081 15300 10251 0.67 1142 14250 9548 0.67 1183 82 75 17250 9488 0.55 1122 16200 8910 0.55 1173 15300 8415 0.55 1224 82 79 18150 7805 0.43 1163 17100 7353 0.43 1214 16050 6902 0.43 1265 84 64 14700 13965 0.95 1000 13500 12825 0.95 1061 12450 11828 0.95 1102 84 68 15450 12824 0.83 1040 14400 11952 0.83 1091 13350 11081 0.83 1153 84 72 16350 11609 0.71 1081 15300 10863 0.71 1142 14250 10118 0.71 1183 84 75 17250 10178 0.59 1122 16200 9558 0.59 1173 15300 9027 0.59 1224 84 79 18150 8531 0.47 1163 17100 8037 0.47 1214 16050 7544 0.47 1265 86 64 14700 14553 0.99 1000 13500 13365 0.99 1061 12450 12326 0.99 1102 86 68 15450 13442 0.87 1040 14400 12528 0.87 1091 13350 11615 0.87 1153 86 72 16350 12263 0.75 1081 15300 11475 0.75 1142 14250 10688 0.75 1183 86 75 17250 10868 0.63 1122 16200 10206 0.63 1173 15300 9639 0.63 1224 86 79 18150 9257 0.51 1163 17100 8721 0.51 1214 16050 8186 0.51 1265 88 64 14700 14700 1.00 1000 13500 13500 1.00 1061 12450 12450 1.00 1102 88 68 15450 14060 0.91 1040 14400 13104 0.91 1091 13350 12149 0.91 1153 88 72 16350 12917 0.79 1081 15300 12087 0.79 1142 14250 11258 0.79 1183 88 75 17250 11558 0.67 1122 16200 10854 0.67 1173 15300 10251 0.67 1224 88 79 18150 9983 0.55 1163 17100 9405 0.55 1214 16050 8828 0.55 1265 90 64 14700 14700 1.00 1000 13500 13500 1.00 1061 12450 12450 1.00 1102 90 68 15450 14678 0.95 1040 14400 13680 0.95 1091 13350 12683 0.95 1153 90 72 16350 13571 0.83 1081 15300 12699 0.83 1142 14250 11828 0.83 1183 90 75 17250 12248 0.71 1122 16200 11502 0.71 1173 15300 10863 0.71 1224 90 79 18150 10709 0.59 1163 17100 10089 0.59 1214 16050 9470 0.59 1265 NOTE CA: Capacity (Btu/h) SHF: Sensible heat factor DB: Dry-bulb temperature SHC: Sensible heat capacity (Btu/h) P.C. : Power consumption (W) WB: Wet-bulb temperature OBD946_86 MUZ-FX18NLHZ CAPACITY (Btu/h): 17200 INPUT (W): 1320 SHF: 0.76 OUTDOOR DB (°F) INDOOR INDOOR 70 77 81 86 DB (°F) WB (°F) CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. 70 64 20210 11722 0.58 1056 19350 11223 0.58 1109 18576 10774 0.58 1162 17888 10375 0.58 1214 70 68 21070 9692 0.46 1109 20210 9297 0.46 1175 19608 9020 0.46 1201 18920 8703 0.46 1254 72 64 20210 12530 0.62 1056 19350 11997 0.62 1109 18576 11517 0.62 1162 17888 11091 0.62 1214 72 68 21070 10535 0.50 1109 20210 10105 0.50 1175 19608 9804 0.50 1201 18920 9460 0.50 1254 72 72 21930 8333 0.38 1148 21156 8039 0.38 1221 20640 7843 0.38 1254 19780 7516 0.38 1307 73 64 20210 13339 0.66 1056 19350 12771 0.66 1109 18576 12260 0.66 1162 17888 11806 0.66 1214 73 68 21070 11378 0.54 1109 20210 10913 0.54 1175 19608 10588 0.54 1201 18920 10217 0.54 1254 73 72 21930 9211 0.42 1148 21156 8886 0.42 1221 20640 8669 0.42 1254 19780 8308 0.42 1307 75 64 20210 14147 0.70 1056 19350 13545 0.70 1109 18576 13003 0.70 1162 17888 12522 0.70 1214 75 68 21070 12221 0.58 1109 20210 11722 0.58 1175 19608 11373 0.58 1201 18920 10974 0.58 1254 75 72 21930 10088 0.46 1148 21156 9732 0.46 1221 20640 9494 0.46 1254 19780 9099 0.46 1307 75 75 23048 7836 0.34 1201 22188 7544 0.34 1267 21672 7368 0.34 1307 20984 7135 0.34 1373 77 64 20210 14955 0.74 1056 19350 14319 0.74 1109 18576 13746 0.74 1162 17888 13237 0.74 1214 77 68 21070 13063 0.62 1109 20210 12530 0.62 1175 19608 12157 0.62 1201 18920 11730 0.62 1254 77 72 21930 10965 0.50 1148 21156 10578 0.50 1221 20640 10320 0.50 1254 19780 9890 0.50 1307 77 75 23048 8758 0.38 1201 22188 8431 0.38 1267 21672 8235 0.38 1307 20984 7974 0.38 1373 79 64 20210 15764 0.78 1056 19350 15093 0.78 1109 18576 14489 0.78 1162 17888 13953 0.78 1214 79 68 21070 13906 0.66 1109 20210 13339 0.66 1175 19608 12941 0.66 1201 18920 12487 0.66 1254 79 72 21930 11842 0.54 1148 21156 11424 0.54 1221 20640 11146 0.54 1254 19780 10681 0.54 1307 79 75 23048 9680 0.42 1201 22188 9319 0.42 1267 21672 9102 0.42 1307 20984 8813 0.42 1373 79 79 23736 7121 0.30 1267 23048 6914 0.30 1333 22704 6811 0.30 1373 22016 6605 0.30 1412 81 64 20210 16572 0.82 1056 19350 15867 0.82 1109 18576 15232 0.82 1162 17888 14668 0.82 1214 81 68 21070 14749 0.70 1109 20210 14147 0.70 1175 19608 13726 0.70 1201 18920 13244 0.70 1254 81 72 21930 12719 0.58 1148 21156 12270 0.58 1221 20640 11971 0.58 1254 19780 11472 0.58 1307 81 75 23048 10602 0.46 1201 22188 10206 0.46 1267 21672 9969 0.46 1307 20984 9653 0.46 1373 81 79 23736 8070 0.34 1267 23048 7836 0.34 1333 22704 7719 0.34 1373 22016 7485 0.34 1412 82 64 20210 17381 0.86 1056 19350 16641 0.86 1109 18576 15975 0.86 1162 17888 15384 0.86 1214 82 68 21070 15592 0.74 1109 20210 14955 0.74 1175 19608 14510 0.74 1201 18920 14001 0.74 1254 82 72 21930 13597 0.62 1148 21156 13117 0.62 1221 20640 12797 0.62 1254 19780 12264 0.62 1307 82 75 23048 11524 0.50 1201 22188 11094 0.50 1267 21672 10836 0.50 1307 20984 10492 0.50 1373 82 79 23736 9020 0.38 1267 23048 8758 0.38 1333 22704 8628 0.38 1373 22016 8366 0.38 1412 84 64 20210 18189 0.90 1056 19350 17415 0.90 1109 18576 16718 0.90 1162 17888 16099 0.90 1214 84 68 21070 16435 0.78 1109 20210 15764 0.78 1175 19608 15294 0.78 1201 18920 14758 0.78 1254 84 72 21930 14474 0.66 1148 21156 13963 0.66 1221 20640 13622 0.66 1254 19780 13055 0.66 1307 84 75 23048 12446 0.54 1201 22188 11982 0.54 1267 21672 11703 0.54 1307 20984 11331 0.54 1373 84 79 23736 9969 0.42 1267 23048 9680 0.42 1333 22704 9536 0.42 1373 22016 9247 0.42 1412 86 64 20210 18997 0.94 1056 19350 18189 0.94 1109 18576 17461 0.94 1162 17888 16815 0.94 1214 86 68 21070 17277 0.82 1109 20210 16572 0.82 1175 19608 16079 0.82 1201 18920 15514 0.82 1254 86 72 21930 15351 0.70 1148 21156 14809 0.70 1221 20640 14448 0.70 1254 19780 13846 0.70 1307 86 75 23048 13368 0.58 1201 22188 12869 0.58 1267 21672 12570 0.58 1307 20984 12171 0.58 1373 86 79 23736 10919 0.46 1267 23048 10602 0.46 1333 22704 10444 0.46 1373 22016 10127 0.46 1412 88 64 20210 19806 0.98 1056 19350 18963 0.98 1109 18576 18204 0.98 1162 17888 17530 0.98 1214 88 68 21070 18120 0.86 1109 20210 17381 0.86 1175 19608 16863 0.86 1201 18920 16271 0.86 1254 88 72 21930 16228 0.74 1148 21156 15655 0.74 1221 20640 15274 0.74 1254 19780 14637 0.74 1307 88 75 23048 14290 0.62 1201 22188 13757 0.62 1267 21672 13437 0.62 1307 20984 13010 0.62 1373 88 79 23736 11868 0.50 1267 23048 11524 0.50 1333 22704 11352 0.50 1373 22016 11008 0.50 1412 90 64 20210 20210 1.00 1056 19350 19350 1.00 1109 18576 18576 1.00 1162 17888 17888 1.00 1214 90 68 21070 18963 0.90 1109 20210 18189 0.90 1175 19608 17647 0.90 1201 18920 17028 0.90 1254 90 72 21930 17105 0.78 1148 21156 16502 0.78 1221 20640 16099 0.78 1254 19780 15428 0.78 1307 90 75 23048 15212 0.66 1201 22188 14644 0.66 1267 21672 14304 0.66 1307 20984 13849 0.66 1373 90 79 23736 12817 0.54 1267 23048 12446 0.54 1333 22704 12260 0.54 1373 22016 11889 0.54 1412 NOTE CA: Capacity (Btu/h) SHF: Sensible heat factor DB: Dry-bulb temperature SHC: Sensible heat capacity (Btu/h) P.C. : Power consumption (W) WB: Wet-bulb temperature OBD946_87 MUZ-FX18NLHZ CAPACITY (Btu/h): 17200 INPUT (W): 1320 SHF: 0.76 OUTDOOR DB (°F) INDOOR INDOOR 95 104 115 DB (°F) WB (°F) CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. 70 64 16856 9776 0.58 1294 15480 8978 0.58 1373 14276 8280 0.58 1426 70 68 17716 8149 0.46 1346 16512 7596 0.46 1412 15308 7042 0.46 1492 72 64 16856 10451 0.62 1294 15480 9598 0.62 1373 14276 8851 0.62 1426 72 68 17716 8858 0.50 1346 16512 8256 0.50 1412 15308 7654 0.50 1492 72 72 18748 7124 0.38 1399 17544 6667 0.38 1478 16340 6209 0.38 1531 73 64 16856 11125 0.66 1294 15480 10217 0.66 1373 14276 9422 0.66 1426 73 68 17716 9567 0.54 1346 16512 8916 0.54 1412 15308 8266 0.54 1492 73 72 18748 7874 0.42 1399 17544 7368 0.42 1478 16340 6863 0.42 1531 75 64 16856 11799 0.70 1294 15480 10836 0.70 1373 14276 9993 0.70 1426 75 68 17716 10275 0.58 1346 16512 9577 0.58 1412 15308 8879 0.58 1492 75 72 18748 8624 0.46 1399 17544 8070 0.46 1478 16340 7516 0.46 1531 75 75 19780 6725 0.34 1452 18576 6316 0.34 1518 17544 5965 0.34 1584 77 64 16856 12473 0.74 1294 15480 11455 0.74 1373 14276 10564 0.74 1426 77 68 17716 10984 0.62 1346 16512 10237 0.62 1412 15308 9491 0.62 1492 77 72 18748 9374 0.50 1399 17544 8772 0.50 1478 16340 8170 0.50 1531 77 75 19780 7516 0.38 1452 18576 7059 0.38 1518 17544 6667 0.38 1584 79 64 16856 13148 0.78 1294 15480 12074 0.78 1373 14276 11135 0.78 1426 79 68 17716 11693 0.66 1346 16512 10898 0.66 1412 15308 10103 0.66 1492 79 72 18748 10124 0.54 1399 17544 9474 0.54 1478 16340 8824 0.54 1531 79 75 19780 8308 0.42 1452 18576 7802 0.42 1518 17544 7368 0.42 1584 79 79 20812 6244 0.30 1505 19608 5882 0.30 1571 18404 5521 0.30 1637 81 64 16856 13822 0.82 1294 15480 12694 0.82 1373 14276 11706 0.82 1426 81 68 17716 12401 0.70 1346 16512 11558 0.70 1412 15308 10716 0.70 1492 81 72 18748 10874 0.58 1399 17544 10176 0.58 1478 16340 9477 0.58 1531 81 75 19780 9099 0.46 1452 18576 8545 0.46 1518 17544 8070 0.46 1584 81 79 20812 7076 0.34 1505 19608 6667 0.34 1571 18404 6257 0.34 1637 82 64 16856 14496 0.86 1294 15480 13313 0.86 1373 14276 12277 0.86 1426 82 68 17716 13110 0.74 1346 16512 12219 0.74 1412 15308 11328 0.74 1492 82 72 18748 11624 0.62 1399 17544 10877 0.62 1478 16340 10131 0.62 1531 82 75 19780 9890 0.50 1452 18576 9288 0.50 1518 17544 8772 0.50 1584 82 79 20812 7909 0.38 1505 19608 7451 0.38 1571 18404 6994 0.38 1637 84 64 16856 15170 0.90 1294 15480 13932 0.90 1373 14276 12848 0.90 1426 84 68 17716 13818 0.78 1346 16512 12879 0.78 1412 15308 11940 0.78 1492 84 72 18748 12374 0.66 1399 17544 11579 0.66 1478 16340 10784 0.66 1531 84 75 19780 10681 0.54 1452 18576 10031 0.54 1518 17544 9474 0.54 1584 84 79 20812 8741 0.42 1505 19608 8235 0.42 1571 18404 7730 0.42 1637 86 64 16856 15845 0.94 1294 15480 14551 0.94 1373 14276 13419 0.94 1426 86 68 17716 14527 0.82 1346 16512 13540 0.82 1412 15308 12553 0.82 1492 86 72 18748 13124 0.70 1399 17544 12281 0.70 1478 16340 11438 0.70 1531 86 75 19780 11472 0.58 1452 18576 10774 0.58 1518 17544 10176 0.58 1584 86 79 20812 9574 0.46 1505 19608 9020 0.46 1571 18404 8466 0.46 1637 88 64 16856 16519 0.98 1294 15480 15170 0.98 1373 14276 13990 0.98 1426 88 68 17716 15236 0.86 1346 16512 14200 0.86 1412 15308 13165 0.86 1492 88 72 18748 13874 0.74 1399 17544 12983 0.74 1478 16340 12092 0.74 1531 88 75 19780 12264 0.62 1452 18576 11517 0.62 1518 17544 10877 0.62 1584 88 79 20812 10406 0.50 1505 19608 9804 0.50 1571 18404 9202 0.50 1637 90 64 16856 16856 1.00 1294 15480 15480 1.00 1373 14276 14276 1.00 1426 90 68 17716 15944 0.90 1346 16512 14861 0.90 1412 15308 13777 0.90 1492 90 72 18748 14623 0.78 1399 17544 13684 0.78 1478 16340 12745 0.78 1531 90 75 19780 13055 0.66 1452 18576 12260 0.66 1518 17544 11579 0.66 1584 90 79 20812 11238 0.54 1505 19608 10588 0.54 1571 18404 9938 0.54 1637 NOTE CA: Capacity (Btu/h) SHF: Sensible heat factor DB: Dry-bulb temperature SHC: Sensible heat capacity (Btu/h) P.C. : Power consumption (W) WB: Wet-bulb temperature OBD946_88 MUZ-FX24NLHZ CAPACITY (Btu/h): 20800 INPUT (W): 1560 SHF: 0.78 OUTDOOR DB (°F) INDOOR INDOOR 70 77 81 86 DB (°F) WB (°F) CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. 70 64 24440 14664 0.60 1248 23400 14040 0.60 1310 22464 13478 0.60 1373 21632 12979 0.60 1435 70 68 25480 12230 0.48 1310 24440 11731 0.48 1388 23712 11382 0.48 1420 22880 10982 0.48 1482 72 64 24440 15642 0.64 1248 23400 14976 0.64 1310 22464 14377 0.64 1373 21632 13844 0.64 1435 72 68 25480 13250 0.52 1310 24440 12709 0.52 1388 23712 12330 0.52 1420 22880 11898 0.52 1482 72 72 26520 10608 0.40 1357 25584 10234 0.40 1443 24960 9984 0.40 1482 23920 9568 0.40 1544 73 64 24440 16619 0.68 1248 23400 15912 0.68 1310 22464 15276 0.68 1373 21632 14710 0.68 1435 73 68 25480 14269 0.56 1310 24440 13686 0.56 1388 23712 13279 0.56 1420 22880 12813 0.56 1482 73 72 26520 11669 0.44 1357 25584 11257 0.44 1443 24960 10982 0.44 1482 23920 10525 0.44 1544 75 64 24440 17597 0.72 1248 23400 16848 0.72 1310 22464 16174 0.72 1373 21632 15575 0.72 1435 75 68 25480 15288 0.60 1310 24440 14664 0.60 1388 23712 14227 0.60 1420 22880 13728 0.60 1482 75 72 26520 12730 0.48 1357 25584 12280 0.48 1443 24960 11981 0.48 1482 23920 11482 0.48 1544 75 75 27872 10034 0.36 1420 26832 9660 0.36 1498 26208 9435 0.36 1544 25376 9135 0.36 1622 77 64 24440 18574 0.76 1248 23400 17784 0.76 1310 22464 17073 0.76 1373 21632 16440 0.76 1435 77 68 25480 16307 0.64 1310 24440 15642 0.64 1388 23712 15176 0.64 1420 22880 14643 0.64 1482 77 72 26520 13790 0.52 1357 25584 13304 0.52 1443 24960 12979 0.52 1482 23920 12438 0.52 1544 77 75 27872 11149 0.40 1420 26832 10733 0.40 1498 26208 10483 0.40 1544 25376 10150 0.40 1622 79 64 24440 19552 0.80 1248 23400 18720 0.80 1310 22464 17971 0.80 1373 21632 17306 0.80 1435 79 68 25480 17326 0.68 1310 24440 16619 0.68 1388 23712 16124 0.68 1420 22880 15558 0.68 1482 79 72 26520 14851 0.56 1357 25584 14327 0.56 1443 24960 13978 0.56 1482 23920 13395 0.56 1544 79 75 27872 12264 0.44 1420 26832 11806 0.44 1498 26208 11532 0.44 1544 25376 11165 0.44 1622 79 79 28704 9185 0.32 1498 27872 8919 0.32 1576 27456 8786 0.32 1622 26624 8520 0.32 1669 81 64 24440 20530 0.84 1248 23400 19656 0.84 1310 22464 18870 0.84 1373 21632 18171 0.84 1435 81 68 25480 18346 0.72 1310 24440 17597 0.72 1388 23712 17073 0.72 1420 22880 16474 0.72 1482 81 72 26520 15912 0.60 1357 25584 15350 0.60 1443 24960 14976 0.60 1482 23920 14352 0.60 1544 81 75 27872 13379 0.48 1420 26832 12879 0.48 1498 26208 12580 0.48 1544 25376 12180 0.48 1622 81 79 28704 10333 0.36 1498 27872 10034 0.36 1576 27456 9884 0.36 1622 26624 9585 0.36 1669 82 64 24440 21507 0.88 1248 23400 20592 0.88 1310 22464 19768 0.88 1373 21632 19036 0.88 1435 82 68 25480 19365 0.76 1310 24440 18574 0.76 1388 23712 18021 0.76 1420 22880 17389 0.76 1482 82 72 26520 16973 0.64 1357 25584 16374 0.64 1443 24960 15974 0.64 1482 23920 15309 0.64 1544 82 75 27872 14493 0.52 1420 26832 13953 0.52 1498 26208 13628 0.52 1544 25376 13196 0.52 1622 82 79 28704 11482 0.40 1498 27872 11149 0.40 1576 27456 10982 0.40 1622 26624 10650 0.40 1669 84 64 24440 22485 0.92 1248 23400 21528 0.92 1310 22464 20667 0.92 1373 21632 19901 0.92 1435 84 68 25480 20384 0.80 1310 24440 19552 0.80 1388 23712 18970 0.80 1420 22880 18304 0.80 1482 84 72 26520 18034 0.68 1357 25584 17397 0.68 1443 24960 16973 0.68 1482 23920 16266 0.68 1544 84 75 27872 15608 0.56 1420 26832 15026 0.56 1498 26208 14676 0.56 1544 25376 14211 0.56 1622 84 79 28704 12630 0.44 1498 27872 12264 0.44 1576 27456 12081 0.44 1622 26624 11715 0.44 1669 86 64 24440 23462 0.96 1248 23400 22464 0.96 1310 22464 21565 0.96 1373 21632 20767 0.96 1435 86 68 25480 21403 0.84 1310 24440 20530 0.84 1388 23712 19918 0.84 1420 22880 19219 0.84 1482 86 72 26520 19094 0.72 1357 25584 18420 0.72 1443 24960 17971 0.72 1482 23920 17222 0.72 1544 86 75 27872 16723 0.60 1420 26832 16099 0.60 1498 26208 15725 0.60 1544 25376 15226 0.60 1622 86 79 28704 13778 0.48 1498 27872 13379 0.48 1576 27456 13179 0.48 1622 26624 12780 0.48 1669 88 64 24440 24440 1.00 1248 23400 23400 1.00 1310 22464 22464 1.00 1373 21632 21632 1.00 1435 88 68 25480 22422 0.88 1310 24440 21507 0.88 1388 23712 20867 0.88 1420 22880 20134 0.88 1482 88 72 26520 20155 0.76 1357 25584 19444 0.76 1443 24960 18970 0.76 1482 23920 18179 0.76 1544 88 75 27872 17838 0.64 1420 26832 17172 0.64 1498 26208 16773 0.64 1544 25376 16241 0.64 1622 88 79 28704 14926 0.52 1498 27872 14493 0.52 1576 27456 14277 0.52 1622 26624 13844 0.52 1669 90 64 24440 24440 1.00 1248 23400 23400 1.00 1310 22464 22464 1.00 1373 21632 21632 1.00 1435 90 68 25480 23442 0.92 1310 24440 22485 0.92 1388 23712 21815 0.92 1420 22880 21050 0.92 1482 90 72 26520 21216 0.80 1357 25584 20467 0.80 1443 24960 19968 0.80 1482 23920 19136 0.80 1544 90 75 27872 18953 0.68 1420 26832 18246 0.68 1498 26208 17821 0.68 1544 25376 17256 0.68 1622 90 79 28704 16074 0.56 1498 27872 15608 0.56 1576 27456 15375 0.56 1622 26624 14909 0.56 1669 NOTE CA: Capacity (Btu/h) SHF: Sensible heat factor DB: Dry-bulb temperature SHC: Sensible heat capacity (Btu/h) P.C. : Power consumption (W) WB: Wet-bulb temperature OBD946_89 MUZ-FX24NLHZ CAPACITY (Btu/h): 20800 INPUT (W): 1560 SHF: 0.78 OUTDOOR DB (°F) INDOOR INDOOR 95 104 115 DB (°F) WB (°F) CA SHC SHF P.C. CA SHC SHF P.C. CA SHC SHF P.C. 70 64 20384 12230 0.60 1529 18720 11232 0.60 1622 17264 10358 0.60 1685 70 68 21424 10284 0.48 1591 19968 9585 0.48 1669 18512 8886 0.48 1763 72 64 20384 13046 0.64 1529 18720 11981 0.64 1622 17264 11049 0.64 1685 72 68 21424 11140 0.52 1591 19968 10383 0.52 1669 18512 9626 0.52 1763 72 72 22672 9069 0.40 1654 21216 8486 0.40 1747 19760 7904 0.40 1810 73 64 20384 13861 0.68 1529 18720 12730 0.68 1622 17264 11740 0.68 1685 73 68 21424 11997 0.56 1591 19968 11182 0.56 1669 18512 10367 0.56 1763 73 72 22672 9976 0.44 1654 21216 9335 0.44 1747 19760 8694 0.44 1810 75 64 20384 14676 0.72 1529 18720 13478 0.72 1622 17264 12430 0.72 1685 75 68 21424 12854 0.60 1591 19968 11981 0.60 1669 18512 11107 0.60 1763 75 72 22672 10883 0.48 1654 21216 10184 0.48 1747 19760 9485 0.48 1810 75 75 23920 8611 0.36 1716 22464 8087 0.36 1794 21216 7638 0.36 1872 77 64 20384 15492 0.76 1529 18720 14227 0.76 1622 17264 13121 0.76 1685 77 68 21424 13711 0.64 1591 19968 12780 0.64 1669 18512 11848 0.64 1763 77 72 22672 11789 0.52 1654 21216 11032 0.52 1747 19760 10275 0.52 1810 77 75 23920 9568 0.40 1716 22464 8986 0.40 1794 21216 8486 0.40 1872 79 64 20384 16307 0.80 1529 18720 14976 0.80 1622 17264 13811 0.80 1685 79 68 21424 14568 0.68 1591 19968 13578 0.68 1669 18512 12588 0.68 1763 79 72 22672 12696 0.56 1654 21216 11881 0.56 1747 19760 11066 0.56 1810 79 75 23920 10525 0.44 1716 22464 9884 0.44 1794 21216 9335 0.44 1872 79 79 25168 8054 0.32 1778 23712 7588 0.32 1856 22256 7122 0.32 1934 81 64 20384 17123 0.84 1529 18720 15725 0.84 1622 17264 14502 0.84 1685 81 68 21424 15425 0.72 1591 19968 14377 0.72 1669 18512 13329 0.72 1763 81 72 22672 13603 0.60 1654 21216 12730 0.60 1747 19760 11856 0.60 1810 81 75 23920 11482 0.48 1716 22464 10783 0.48 1794 21216 10184 0.48 1872 81 79 25168 9060 0.36 1778 23712 8536 0.36 1856 22256 8012 0.36 1934 82 64 20384 17938 0.88 1529 18720 16474 0.88 1622 17264 15192 0.88 1685 82 68 21424 16282 0.76 1591 19968 15176 0.76 1669 18512 14069 0.76 1763 82 72 22672 14510 0.64 1654 21216 13578 0.64 1747 19760 12646 0.64 1810 82 75 23920 12438 0.52 1716 22464 11681 0.52 1794 21216 11032 0.52 1872 82 79 25168 10067 0.40 1778 23712 9485 0.40 1856 22256 8902 0.40 1934 84 64 20384 18753 0.92 1529 18720 17222 0.92 1622 17264 15883 0.92 1685 84 68 21424 17139 0.80 1591 19968 15974 0.80 1669 18512 14810 0.80 1763 84 72 22672 15417 0.68 1654 21216 14427 0.68 1747 19760 13437 0.68 1810 84 75 23920 13395 0.56 1716 22464 12580 0.56 1794 21216 11881 0.56 1872 84 79 25168 11074 0.44 1778 23712 10433 0.44 1856 22256 9793 0.44 1934 86 64 20384 19569 0.96 1529 18720 17971 0.96 1622 17264 16573 0.96 1685 86 68 21424 17996 0.84 1591 19968 16773 0.84 1669 18512 15550 0.84 1763 86 72 22672 16324 0.72 1654 21216 15276 0.72 1747 19760 14227 0.72 1810 86 75 23920 14352 0.60 1716 22464 13478 0.60 1794 21216 12730 0.60 1872 86 79 25168 12081 0.48 1778 23712 11382 0.48 1856 22256 10683 0.48 1934 88 64 20384 20384 1.00 1529 18720 18720 1.00 1622 17264 17264 1.00 1685 88 68 21424 18853 0.88 1591 19968 17572 0.88 1669 18512 16291 0.88 1763 88 72 22672 17231 0.76 1654 21216 16124 0.76 1747 19760 15018 0.76 1810 88 75 23920 15309 0.64 1716 22464 14377 0.64 1794 21216 13578 0.64 1872 88 79 25168 13087 0.52 1778 23712 12330 0.52 1856 22256 11573 0.52 1934 90 64 20384 20384 1.00 1529 18720 18720 1.00 1622 17264 17264 1.00 1685 90 68 21424 19710 0.92 1591 19968 18371 0.92 1669 18512 17031 0.92 1763 90 72 22672 18138 0.80 1654 21216 16973 0.80 1747 19760 15808 0.80 1810 90 75 23920 16266 0.68 1716 22464 15276 0.68 1794 21216 14427 0.68 1872 90 79 25168 14094 0.56 1778 23712 13279 0.56 1856 22256 12463 0.56 1934 NOTE CA: Capacity (Btu/h) SHF: Sensible heat factor DB: Dry-bulb temperature SHC: Sensible heat capacity (Btu/h) P.C. : Power consumption (W) WB: Wet-bulb temperature OBD946_90 16 CAPACITY CORRECTION RATIO CURVE FOR PIPING LENGTH Correction ratio of capacity according to the length of piping (cooling) Indoor unit 06 class Indoor unit 100% 24 class Indoor unit 99% 15 class 98% Indoor unit 97% 18 class 96% Indoor unit %) 09 class ( 95% Indoor unit 94% 30 class 93% Indoor unit 36 class 92% Indoor unit 91% 12 class tio of capacity 90% Ra 89% 88% 87% 86% 85% 0 16.4 32.8 49.2 65.6 82.0 98.4 114.8 (ft.) 5 10 15 20 25 30 35 (m) Actual length of refrigerant piping Correction ratio of capacity according to the length of piping (heating) 100% 99% %)98% ( 97% tio of capacity Ra 96% 95% 0 16.4 32.8 49.2 65.6 82.0 98.4 114.8 (ft.) 5 10 15 20 25 30 35 (m) Actual length of refrigerant piping The length intended for the capacity calculation, which counts the length of refrigerant piping and the number of bends, is called actual length. Length of refrigerant piping (ft.) + ( Number of bends × 0.984 ft. ) = Actual length of refrigerant piping (ft.) [Length of refrigerant piping (m) + ( Number of bends × 0.3 m ) = Actual length of refrigerant piping (m)] OBD946_91 17 PART LOAD CAPACITY CHART MUZ-FX06NLHZ Rated Q(Btu/h): 6000 1) COOLING W: 280 Indoor W.B. 71°F / 21.7°C 67°F / 19.4°C 63°F / 17.2°C Outdoor D.B. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. (°F) (°C) 115 46.1 Q(Btu/h) 12640 5520 9470 6430 3250 1530 11970 5130 8970 6090 3080 1450 11250 4680 8420 5720 2890 1360 W 1460 320 1090 720 350 140 1380 310 1020 680 320 130 1310 300 980 650 310 130 110 43.3 Q(Btu/h) 13200 5760 9890 6710 3400 1600 12500 5360 9370 6360 3220 1520 11750 4910 8800 5980 3020 1430 W 1430 320 1060 710 350 140 1350 310 1000 670 320 130 1290 300 960 640 310 130 105 40.6 Q(Btu/h) 13750 6000 10310 6990 3530 1670 13020 5580 9760 6620 3350 1580 12230 5130 9170 6220 3140 1480 W 1390 310 1040 690 340 140 1310 300 980 650 310 130 1250 290 940 620 300 130 100 37.8 Q(Btu/h) 14270 6230 10700 7250 3670 1730 13510 5790 10130 6870 3480 1640 12690 5390 9510 6450 3260 1540 W 1350 300 1010 670 330 140 1280 290 950 630 300 130 1220 280 910 610 290 130 95 35.0 Q(Btu/h) 14780 6450 11080 7520 3800 1790 14000 6000 10490 7120 3600 1700 13160 5640 9850 6690 3380 1600 W 1310 290 980 650 310 130 1240 280 920 610 290 120 1180 270 880 590 280 120 90 32.2 Q(Btu/h) 15380 6660 11520 7820 3960 1870 14560 6240 10910 7410 3750 1770 13680 5850 10250 6960 3520 1660 W 1270 280 950 620 300 130 1200 270 890 590 280 120 1140 260 860 570 270 120 85 29.4 Q(Btu/h) 15970 6870 11960 8120 4100 1940 15120 6480 11330 7690 3890 1840 14210 6060 10640 7220 3650 1730 W 1220 270 910 590 290 120 1150 260 850 560 270 110 1090 250 820 540 260 110 80 26.7 Q(Btu/h) 16560 7110 12410 8420 4260 2020 15680 6720 11750 7980 4040 1910 14730 6300 11040 7500 3790 1790 W 1160 260 860 570 280 120 1100 250 810 540 260 110 1050 240 780 520 250 110 75 23.9 Q(Btu/h) 17150 7350 12850 8720 4410 2080 16240 6960 12170 8260 4180 1970 15260 6540 11430 7760 3920 1850 W 1100 250 820 540 260 110 1040 240 770 510 240 100 990 220 740 490 230 100 70 21.1 Q(Btu/h) 17740 7600 13290 9020 4560 2150 16800 7200 12590 8540 4320 2040 15790 6770 11820 8020 4050 1920 W 1050 230 780 520 250 110 990 220 730 490 230 100 940 200 700 470 220 100 65 18.3 Q(Btu/h) 15150 6490 11320 7660 3820 1750 14350 6150 10720 7250 3620 1660 13490 5780 10060 6810 3390 1560 W 950 210 720 480 240 110 891 200 670 450 220 100 850 180 640 430 210 100 60 15.6 Q(Btu/h) 15150 6490 11320 7660 3820 1750 14350 6150 10720 7250 3620 1660 13490 5780 10060 6810 3390 1560 W 950 210 720 480 240 110 891 200 670 450 220 100 850 180 640 430 210 100 55 12.8 Q(Btu/h) 15150 6490 11320 7660 3820 1750 14350 6150 10720 7250 3620 1660 13490 5780 10060 6810 3390 1560 W 950 210 720 480 240 110 891 200 670 450 220 100 850 180 640 430 210 100 50 10.0 Q(Btu/h) 15150 6490 11320 7660 3820 1750 14350 6150 10720 7250 3620 1660 13490 5780 10060 6810 3390 1560 W 950 210 720 480 240 110 891 200 670 450 220 100 850 180 640 430 210 100 45 7.2 Q(Btu/h) 15150 6490 11320 7660 3820 1750 14350 6150 10720 7250 3620 1660 13490 5780 10060 6810 3390 1560 W 950 210 720 480 240 110 891 200 670 450 220 100 850 180 640 430 210 100 40 4.4 Q(Btu/h) 15150 6490 11320 7660 3820 1750 14350 6150 10720 7250 3620 1660 13490 5780 10060 6810 3390 1560 W 950 210 720 480 240 110 891 200 670 450 220 100 850 180 640 430 210 100 35 1.7 Q(Btu/h) 15150 6490 11320 7660 3820 1750 14350 6150 10720 7250 3620 1660 13490 5780 10060 6810 3390 1560 W 950 210 720 480 240 110 891 200 670 450 220 100 850 180 640 430 210 100 30 -1.1 Q(Btu/h) 15150 6490 11320 7660 3820 1750 14350 6150 10720 7250 3620 1660 13490 5780 10060 6810 3390 1560 W 950 210 720 480 240 110 891 200 670 450 220 100 850 180 640 430 210 100 25 -3.9 Q(Btu/h) 15150 6490 11320 7660 3820 1750 14350 6150 10720 7250 3620 1660 13490 5780 10060 6810 3390 1560 W 950 210 720 480 240 110 891 200 670 450 220 100 850 180 640 430 210 100 20 -6.7 Q(Btu/h) 15150 6490 11320 7660 3820 1750 14350 6150 10720 7250 3620 1660 13490 5780 10060 6810 3390 1560 W 950 210 720 480 240 110 891 200 670 450 220 100 850 180 640 430 210 100 15 -9.4 Q(Btu/h) 15150 6490 11320 7660 3820 1750 14350 6150 10720 7250 3620 1660 13490 5780 10060 6810 3390 1560 W 950 210 720 480 240 110 891 200 670 450 220 100 850 180 640 430 210 100 * It may not reach the above capacities in low ambient temperatures. OBD946_92 MUZ-FX06NLHZ Rated Q(Btu/h): 9000 2) HEATING W: 540 Indoor D.B. 78.8°F / 26.0°C 70°F / 21.1°C 59°F / 15.0°C Outdoor W.B. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. (°F) (°C) 65 18.3 Q(Btu/h) 24980 11240 18720 12550 6170 2260 26000 11700 19480 13060 6420 2350 27020 12160 20240 13570 6670 2440 W 2010 610 1510 1010 500 180 1910 580 1430 960 470 170 1810 550 1350 910 440 160 60 15.6 Q(Btu/h) 23630 10640 17690 11870 5840 2140 24650 11100 18460 12380 6090 2230 25670 11560 19230 12890 6340 2320 W 2000 610 1500 1000 500 180 1900 580 1420 950 470 170 1800 550 1340 900 440 160 55 12.8 Q(Btu/h) 22260 10020 16670 11180 5500 2020 23300 10490 17450 11700 5760 2110 24340 10960 18230 12220 6020 2200 W 1980 600 1490 990 500 180 1880 570 1410 940 470 170 1780 540 1330 890 440 160 50 10.0 Q(Btu/h) 20890 9400 15650 10490 5160 1890 21950 9880 16440 11020 5420 1990 23010 10360 17230 11550 5680 2090 W 1950 590 1460 990 500 180 1850 560 1390 940 470 170 1750 530 1320 890 440 160 45 7.2 Q(Btu/h) 19530 8790 14630 9810 4830 1770 20600 9270 15430 10340 5090 1870 21670 9750 16230 10870 5350 1970 W 1910 580 1420 950 460 170 1810 550 1350 900 440 160 1710 520 1280 850 420 150 43 6.1 Q(Btu/h) 18940 8520 14180 9510 4670 1610 20000 9000 14970 10040 4930 1700 21060 9480 15760 10570 5190 1790 W 1860 570 1390 940 450 130 1770 540 1320 890 430 120 1680 510 1250 840 410 110 40 4.4 Q(Btu/h) 17810 8140 13340 8950 4400 1620 18850 8620 14120 9470 4660 1710 19890 9100 14900 9990 4920 1800 W 1820 560 1360 910 440 160 1730 530 1290 860 420 150 1640 500 1220 810 400 140 35 1.7 Q(Btu/h) 16660 7500 12480 8370 4110 1510 17700 7970 13260 8890 4370 1600 18740 8440 14040 9410 4630 1690 W 1770 540 1330 880 430 160 1680 510 1260 840 410 150 1590 480 1190 800 390 140 30 -1.1 Q(Btu/h) 15990 6900 11980 8040 3950 1440 17050 7360 12780 8570 4210 1540 18110 7820 13580 9100 4470 1640 W 1750 520 1320 880 430 160 1660 490 1250 840 410 150 1570 460 1180 800 390 140 25 -3.9 Q(Btu/h) 15300 6300 11460 7680 3780 1390 16400 6750 12280 8230 4050 1490 17500 7200 13100 8780 4320 1590 W 1730 480 1300 870 430 160 1640 460 1230 830 410 150 1550 440 1160 790 390 140 20 -6.7 Q(Btu/h) 14280 5700 10700 7180 3530 1300 15400 6150 11540 7740 3810 1400 16520 6600 12380 8300 4090 1500 W 1700 450 1260 840 410 150 1610 430 1200 800 390 140 1520 410 1140 760 370 130 15 -9.4 Q(Btu/h) 13230 5090 9910 6650 3270 1200 14400 5540 10790 7240 3560 1310 15570 5990 11670 7830 3850 1420 W 1650 410 1230 830 410 150 1570 390 1170 790 390 140 1490 370 1110 750 370 130 10 -12.2 Q(Btu/h) 12250 4450 9170 6150 3030 1110 13500 4910 10110 6780 3340 1220 14750 5370 11050 7410 3650 1330 W 1640 370 1230 830 410 150 1560 350 1170 790 390 140 1480 330 1110 750 370 130 5 -15.0 Q(Btu/h) 11220 3810 8410 5640 2770 1020 12600 4280 9440 6330 3110 1140 13980 4750 10470 7020 3450 1260 W 1630 330 1220 820 410 150 1550 310 1160 780 390 140 1470 290 1100 740 370 130 0 -17.8 Q(Btu/h) 9900 3790 7410 4970 2440 890 11400 4370 8540 5720 2810 1030 12900 4950 9670 6470 3180 1170 W 1570 500 1180 790 390 150 1490 470 1120 750 370 140 1410 440 1060 710 350 130 -5 -20.6 Q(Btu/h) 8540 3730 6400 4290 2110 770 10200 4450 7640 5120 2520 920 11860 5170 8880 5950 2930 1070 W 1510 650 1130 760 380 140 1430 620 1070 720 360 130 1350 590 1010 680 340 120 -10 -23.3 Q(Btu/h) 7180 3130 5380 3600 1770 650 9000 3930 6740 4520 2220 810 10820 4730 8100 5440 2670 970 W 1440 630 1070 730 360 130 1370 600 1020 690 340 120 1300 570 970 650 320 110 * Above data is for heating operation without any frost. OBD946_93 MUZ-FX09NLHZ Rated Q(Btu/h): 9000 1) COOLING W: 490 Indoor W.B. 71°F / 21.7°C 67°F / 19.4°C 63°F / 17.2°C Outdoor D.B. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. (°F) (°C) 115 46.1 Q(Btu/h) 13550 8280 10350 6970 3770 2260 12830 7700 9800 6600 3570 2140 12060 7020 9210 6190 3360 2010 W 1860 560 1390 880 420 190 1750 540 1310 830 390 180 1660 520 1240 790 380 180 110 43.3 Q(Btu/h) 14140 8640 10810 7270 3940 2360 13390 8040 10230 6890 3730 2240 12580 7360 9610 6470 3510 2110 W 1810 550 1360 870 410 190 1710 530 1280 820 380 180 1620 510 1220 780 370 180 105 40.6 Q(Btu/h) 14740 9000 11260 7580 4110 2460 13950 8370 10660 7180 3890 2330 13110 7700 10020 6740 3660 2190 W 1770 540 1330 850 400 180 1670 520 1250 800 370 170 1580 500 1190 760 360 170 100 37.8 Q(Btu/h) 15300 9340 11680 7870 4260 2550 14480 8690 11060 7450 4040 2420 13610 8080 10390 6990 3800 2280 W 1730 530 1290 830 380 180 1630 510 1220 780 360 170 1540 490 1160 740 350 170 95 35.0 Q(Btu/h) 15840 9680 12110 8150 4410 2640 15000 9000 11460 7720 4180 2500 14090 8460 10770 7250 3930 2350 W 1680 510 1250 800 370 170 1580 490 1180 750 350 160 1500 470 1120 710 340 160 90 32.2 Q(Btu/h) 16480 10000 12590 8480 4590 2740 15600 9360 11920 8030 4350 2600 14660 8780 11200 7540 4090 2450 W 1610 500 1210 770 360 170 1520 470 1140 720 340 160 1440 450 1080 690 330 160 85 29.4 Q(Btu/h) 17110 10310 13080 8810 4760 2850 16200 9720 12380 8340 4510 2700 15220 9090 11630 7830 4240 2540 W 1550 480 1160 730 340 160 1460 450 1090 690 320 150 1380 430 1030 660 310 150 80 26.7 Q(Btu/h) 17750 10670 13560 9130 4940 2950 16800 10080 12840 8650 4680 2800 15790 9450 12070 8120 4400 2640 W 1480 460 1100 700 330 150 1400 430 1040 660 310 140 1330 410 990 630 300 140 75 23.9 Q(Btu/h) 18380 11030 14040 9460 5120 3060 17400 10440 13290 8960 4850 2900 16350 9810 12490 8410 4560 2730 W 1410 440 1050 670 310 140 1330 410 990 630 290 130 1260 390 940 600 280 130 70 21.1 Q(Btu/h) 19010 11410 14530 9780 5300 3170 18000 10800 13750 9260 5020 3000 16910 10150 12920 8690 4720 2820 W 1340 420 1000 640 300 140 1260 390 940 600 280 130 1190 370 890 570 270 130 65 18.3 Q(Btu/h) 16240 9750 12290 8110 4160 2290 15380 9230 11630 7680 3940 2170 14450 8670 10930 7210 3700 2040 W 1620 510 1220 810 420 240 1524 470 1150 760 390 220 1440 450 1090 720 380 220 60 15.6 Q(Btu/h) 16240 9750 12290 8110 4160 2290 15380 9230 11630 7680 3940 2170 14450 8670 10930 7210 3700 2040 W 1620 510 1220 810 420 240 1524 470 1150 760 390 220 1440 450 1090 720 380 220 55 12.8 Q(Btu/h) 16240 9750 12290 8110 4160 2290 15380 9230 11630 7680 3940 2170 14450 8670 10930 7210 3700 2040 W 1620 510 1220 810 420 240 1524 470 1150 760 390 220 1440 450 1090 720 380 220 50 10.0 Q(Btu/h) 16240 9750 12290 8110 4160 2290 15380 9230 11630 7680 3940 2170 14450 8670 10930 7210 3700 2040 W 1620 510 1220 810 420 240 1524 470 1150 760 390 220 1440 450 1090 720 380 220 45 7.2 Q(Btu/h) 16240 9750 12290 8110 4160 2290 15380 9230 11630 7680 3940 2170 14450 8670 10930 7210 3700 2040 W 1620 510 1220 810 420 240 1524 470 1150 760 390 220 1440 450 1090 720 380 220 40 4.4 Q(Btu/h) 16240 9750 12290 8110 4160 2290 15380 9230 11630 7680 3940 2170 14450 8670 10930 7210 3700 2040 W 1620 510 1220 810 420 240 1524 470 1150 760 390 220 1440 450 1090 720 380 220 35 1.7 Q(Btu/h) 16240 9750 12290 8110 4160 2290 15380 9230 11630 7680 3940 2170 14450 8670 10930 7210 3700 2040 W 1620 510 1220 810 420 240 1524 470 1150 760 390 220 1440 450 1090 720 380 220 30 -1.1 Q(Btu/h) 16240 9750 12290 8110 4160 2290 15380 9230 11630 7680 3940 2170 14450 8670 10930 7210 3700 2040 W 1620 510 1220 810 420 240 1524 470 1150 760 390 220 1440 450 1090 720 380 220 25 -3.9 Q(Btu/h) 16240 9750 12290 8110 4160 2290 15380 9230 11630 7680 3940 2170 14450 8670 10930 7210 3700 2040 W 1620 510 1220 810 420 240 1524 470 1150 760 390 220 1440 450 1090 720 380 220 20 -6.7 Q(Btu/h) 16240 9750 12290 8110 4160 2290 15380 9230 11630 7680 3940 2170 14450 8670 10930 7210 3700 2040 W 1620 510 1220 810 420 240 1524 470 1150 760 390 220 1440 450 1090 720 380 220 15 -9.4 Q(Btu/h) 16240 9750 12290 8110 4160 2290 15380 9230 11630 7680 3940 2170 14450 8670 10930 7210 3700 2040 W 1620 510 1220 810 420 240 1524 470 1150 760 390 220 1440 450 1090 720 380 220 * It may not reach the above capacities in low ambient temperatures. OBD946_94 MUZ-FX09NLHZ Rated Q(Btu/h): 12000 2) HEATING W: 710 Indoor D.B. 78.8°F / 26.0°C 70°F / 21.1°C 59°F / 15.0°C Outdoor W.B. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. (°F) (°C) 65 18.3 Q(Btu/h) 26610 14990 20090 13300 6780 3260 27690 15600 20910 13840 7060 3390 28770 16210 21730 14380 7340 3520 W 2420 810 1830 1210 620 290 2300 770 1740 1150 590 280 2180 730 1650 1090 560 270 60 15.6 Q(Btu/h) 25160 14180 19000 12580 6410 3080 26250 14790 19820 13120 6690 3210 27340 15400 20640 13660 6970 3340 W 2400 800 1820 1210 620 290 2280 760 1730 1150 590 280 2160 720 1640 1090 560 270 55 12.8 Q(Btu/h) 23700 13360 17900 11860 6050 2900 24810 13980 18740 12410 6330 3040 25920 14600 19580 12960 6610 3180 W 2380 790 1800 1190 610 290 2260 750 1710 1130 580 280 2140 710 1620 1070 550 270 50 10.0 Q(Btu/h) 22250 12540 16800 11130 5670 2720 23380 13170 17650 11690 5960 2860 24510 13800 18500 12250 6250 3000 W 2340 780 1760 1160 590 280 2220 740 1670 1100 560 270 2100 700 1580 1040 530 260 45 7.2 Q(Btu/h) 20810 11720 15700 10390 5300 2540 21940 12360 16560 10960 5590 2680 23070 13000 17420 11530 5880 2820 W 2290 760 1730 1150 590 280 2170 720 1640 1090 560 270 2050 680 1550 1030 530 260 43 6.1 Q(Btu/h) 20170 11360 15240 10090 5150 2940 21300 12000 16090 10660 5440 3100 22430 12640 16940 11230 5730 3260 W 2240 750 1690 1120 570 190 2130 710 1600 1060 540 180 2020 670 1510 1000 510 170 40 4.4 Q(Btu/h) 19650 10860 14840 9840 5020 2410 20800 11490 15710 10410 5310 2550 21950 12120 16580 10980 5600 2690 W 2230 740 1680 1110 570 270 2120 700 1590 1050 540 260 2010 660 1500 990 510 250 35 1.7 Q(Btu/h) 18730 10000 14150 9370 4780 2300 19900 10620 15030 9950 5080 2440 21070 11240 15910 10530 5380 2580 W 2200 710 1660 1110 570 270 2090 670 1580 1050 540 260 1980 630 1500 990 510 250 30 -1.1 Q(Btu/h) 17820 9200 13450 8900 4540 2180 19000 9810 14340 9490 4840 2320 20180 10420 15230 10080 5140 2460 W 2180 670 1650 1100 560 260 2070 640 1570 1040 530 250 1960 610 1490 980 500 240 25 -3.9 Q(Btu/h) 16890 8400 12750 8440 4310 2070 18100 9000 13660 9040 4620 2220 19310 9600 14570 9640 4930 2370 W 2160 640 1630 1090 560 260 2050 610 1550 1030 530 250 1940 580 1470 970 500 240 20 -6.7 Q(Btu/h) 15950 7590 12040 7970 4060 1950 17200 8190 12990 8600 4380 2100 18450 8790 13940 9230 4700 2250 W 2130 590 1600 1050 540 250 2020 560 1520 1000 510 240 1910 530 1440 950 480 230 15 -9.4 Q(Btu/h) 14980 6780 11310 7490 3820 1840 16300 7380 12310 8150 4160 2000 17620 7980 13310 8810 4500 2160 W 2110 540 1600 1050 540 250 2000 510 1520 1000 510 240 1890 480 1440 950 480 230 10 -12.2 Q(Btu/h) 14060 5930 10620 7040 3590 1720 15500 6540 11710 7760 3960 1900 16940 7150 12800 8480 4330 2080 W 2090 480 1580 1050 540 250 1980 460 1500 1000 510 240 1870 440 1420 950 480 230 5 -15.0 Q(Btu/h) 13090 5080 9890 6550 3340 1600 14700 5700 11100 7350 3750 1800 16310 6320 12310 8150 4160 2000 W 2050 420 1550 1020 520 250 1950 400 1470 970 490 240 1850 380 1390 920 460 230 0 -17.8 Q(Btu/h) 11980 5040 9040 5990 3060 1470 13800 5810 10420 6900 3520 1690 15620 6580 11800 7810 3980 1910 W 1980 650 1500 990 510 240 1880 620 1420 940 480 230 1780 590 1340 890 450 220 -5 -20.6 Q(Btu/h) 10810 4960 8150 5390 2760 1320 12900 5920 9730 6440 3290 1580 14990 6880 11310 7490 3820 1840 W 1910 870 1440 960 480 230 1810 830 1370 910 460 220 1710 790 1300 860 440 210 -10 -23.3 Q(Btu/h) 9570 4390 7230 4790 2440 1170 12000 5510 9070 6000 3060 1470 14430 6630 10910 7210 3680 1770 W 1840 840 1390 920 460 220 1750 800 1320 870 440 210 1660 760 1250 820 420 200 * Above data is for heating operation without any frost. OBD946_95 MUZ-FX12NLHZ Rated Q(Btu/h): 12000 1) COOLING W: 780 Indoor W.B. 71°F / 21.7°C 67°F / 19.4°C 63°F / 17.2°C Outdoor D.B. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. (°F) (°C) 115 46.1 Q(Btu/h) 14540 11040 11030 7520 3840 2260 13770 10260 10440 7120 3630 2140 12940 9360 9810 6690 3410 2010 W 1960 900 1450 940 420 190 1840 870 1370 890 390 180 1760 830 1300 850 380 180 110 43.3 Q(Btu/h) 15170 11520 11520 7860 4010 2360 14370 10710 10900 7440 3790 2240 13500 9810 10250 6990 3560 2110 W 1920 880 1420 920 410 190 1800 850 1340 870 380 180 1720 820 1270 830 370 180 105 40.6 Q(Btu/h) 15800 12000 12000 8180 4170 2460 14970 11160 11360 7750 3950 2330 14060 10260 10680 7280 3710 2190 W 1870 860 1380 900 400 180 1760 830 1300 850 370 170 1680 800 1240 810 360 170 100 37.8 Q(Btu/h) 16410 12450 12460 8490 4330 2550 15540 11580 11790 8040 4100 2420 14600 10770 11080 7560 3850 2280 W 1820 840 1340 880 380 180 1710 810 1270 830 360 170 1640 770 1210 790 350 170 95 35.0 Q(Btu/h) 17000 12900 12900 8800 4490 2640 16100 12000 12210 8330 4250 2500 15130 11280 11480 7830 3990 2350 W 1770 820 1300 850 370 170 1660 780 1230 800 350 160 1590 740 1170 760 340 160 90 32.2 Q(Btu/h) 17680 13320 13420 9150 4670 2740 16750 12480 12700 8670 4420 2600 15740 11700 11940 8150 4150 2450 W 1700 790 1260 820 360 170 1600 750 1190 770 340 160 1530 720 1130 740 330 160 85 29.4 Q(Btu/h) 18360 13740 13940 9500 4850 2850 17390 12960 13190 9000 4590 2700 16340 12120 12400 8460 4310 2540 W 1640 760 1210 780 340 160 1540 720 1140 740 320 150 1470 690 1080 710 310 150 80 26.7 Q(Btu/h) 19040 14220 14450 9850 5030 2950 18040 13440 13680 9330 4760 2800 16950 12600 12860 8770 4470 2640 W 1570 730 1150 750 330 150 1470 690 1090 710 310 140 1410 660 1040 680 300 140 75 23.9 Q(Btu/h) 19720 14700 14960 10200 5210 3060 18680 13920 14160 9660 4930 2900 17550 13080 13310 9080 4630 2730 W 1480 690 1090 710 310 140 1390 660 1030 670 290 130 1330 620 980 640 280 130 70 21.1 Q(Btu/h) 20400 15210 15480 10560 5390 3170 19320 14400 14650 10000 5100 3000 18150 13530 13770 9400 4790 2820 W 1410 650 1040 680 300 140 1320 620 980 640 280 130 1260 580 930 610 270 130 65 18.3 Q(Btu/h) 17420 12990 13130 8820 4310 2370 16500 12300 12430 8350 4080 2240 15500 11560 11680 7850 3830 2110 W 1630 750 1210 820 410 230 1524 720 1140 770 380 210 1450 670 1080 730 370 210 60 15.6 Q(Btu/h) 17420 12990 13130 8820 4310 2370 16500 12300 12430 8350 4080 2240 15500 11560 11680 7850 3830 2110 W 1630 750 1210 820 410 230 1524 720 1140 770 380 210 1450 670 1080 730 370 210 55 12.8 Q(Btu/h) 17420 12990 13130 8820 4310 2370 16500 12300 12430 8350 4080 2240 15500 11560 11680 7850 3830 2110 W 1630 750 1210 820 410 230 1524 720 1140 770 380 210 1450 670 1080 730 370 210 50 10.0 Q(Btu/h) 17420 12990 13130 8820 4310 2370 16500 12300 12430 8350 4080 2240 15500 11560 11680 7850 3830 2110 W 1630 750 1210 820 410 230 1524 720 1140 770 380 210 1450 670 1080 730 370 210 45 7.2 Q(Btu/h) 17420 12990 13130 8820 4310 2370 16500 12300 12430 8350 4080 2240 15500 11560 11680 7850 3830 2110 W 1630 750 1210 820 410 230 1524 720 1140 770 380 210 1450 670 1080 730 370 210 40 4.4 Q(Btu/h) 17420 12990 13130 8820 4310 2370 16500 12300 12430 8350 4080 2240 15500 11560 11680 7850 3830 2110 W 1630 750 1210 820 410 230 1524 720 1140 770 380 210 1450 670 1080 730 370 210 35 1.7 Q(Btu/h) 17420 12990 13130 8820 4310 2370 16500 12300 12430 8350 4080 2240 15500 11560 11680 7850 3830 2110 W 1630 750 1210 820 410 230 1524 720 1140 770 380 210 1450 670 1080 730 370 210 30 -1.1 Q(Btu/h) 17420 12990 13130 8820 4310 2370 16500 12300 12430 8350 4080 2240 15500 11560 11680 7850 3830 2110 W 1630 750 1210 820 410 230 1524 720 1140 770 380 210 1450 670 1080 730 370 210 25 -3.9 Q(Btu/h) 17420 12990 13130 8820 4310 2370 16500 12300 12430 8350 4080 2240 15500 11560 11680 7850 3830 2110 W 1630 750 1210 820 410 230 1524 720 1140 770 380 210 1450 670 1080 730 370 210 20 -6.7 Q(Btu/h) 17420 12990 13130 8820 4310 2370 16500 12300 12430 8350 4080 2240 15500 11560 11680 7850 3830 2110 W 1630 750 1210 820 410 230 1524 720 1140 770 380 210 1450 670 1080 730 370 210 15 -9.4 Q(Btu/h) 17420 12990 13130 8820 4310 2370 16500 12300 12430 8350 4080 2240 15500 11560 11680 7850 3830 2110 W 1630 750 1210 820 410 230 1524 720 1140 770 380 210 1450 670 1080 730 370 210 * It may not reach the above capacities in low ambient temperatures. OBD946_96 MUZ-FX12NLHZ Rated Q(Btu/h): 13200 2) HEATING W: 920 Indoor D.B. 78.8°F / 26.0°C 70°F / 21.1°C 59°F / 15.0°C Outdoor W.B. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. (°F) (°C) 65 18.3 Q(Btu/h) 29350 16490 22090 14820 7260 3350 30550 17160 22990 15420 7560 3490 31750 17830 23890 16020 7860 3630 W 2430 1040 1830 1230 610 280 2310 990 1740 1170 580 270 2190 940 1650 1110 550 260 60 15.6 Q(Btu/h) 27770 15600 20900 14010 6870 3170 28970 16270 21800 14620 7170 3310 30170 16940 22700 15230 7470 3450 W 2410 1040 1810 1210 590 270 2290 990 1720 1150 560 260 2170 940 1630 1090 530 250 55 12.8 Q(Btu/h) 26160 14690 19680 13200 6480 2990 27380 15380 20600 13820 6780 3130 28600 16070 21520 14440 7080 3270 W 2390 1030 1790 1200 590 270 2270 980 1700 1140 560 260 2150 930 1610 1080 530 250 50 10.0 Q(Btu/h) 24560 13790 18470 12390 6080 2810 25800 14490 19410 13020 6390 2950 27040 15190 20350 13650 6700 3090 W 2350 1010 1770 1190 590 270 2230 960 1680 1130 560 260 2110 910 1590 1070 530 250 45 7.2 Q(Btu/h) 22960 12900 17270 11590 5680 2620 24210 13600 18210 12220 5990 2760 25460 14300 19150 12850 6300 2900 W 2300 990 1730 1160 570 260 2180 940 1640 1100 540 250 2060 890 1550 1040 510 240 43 6.1 Q(Btu/h) 22250 12500 16740 11230 5510 2940 23500 13200 17680 11860 5820 3100 24750 13900 18620 12490 6130 3260 W 2250 970 1710 1150 560 190 2140 920 1620 1090 530 180 2030 870 1530 1030 500 170 40 4.4 Q(Btu/h) 21640 11940 16280 10920 5360 2480 22900 12640 17230 11560 5670 2620 24160 13340 18180 12200 5980 2760 W 2250 960 1710 1150 560 250 2140 910 1620 1090 530 240 2030 860 1530 1030 500 230 35 1.7 Q(Btu/h) 20710 11000 15580 10450 5130 2370 22000 11680 16550 11100 5450 2520 23290 12360 17520 11750 5770 2670 W 2250 920 1710 1150 560 250 2140 870 1620 1090 530 240 2030 820 1530 1030 500 230 30 -1.1 Q(Btu/h) 19690 10120 14810 9940 4880 2250 21000 10790 15800 10600 5200 2400 22310 11460 16790 11260 5520 2550 W 2250 870 1710 1150 560 250 2140 830 1620 1090 530 240 2030 790 1530 1030 500 230 25 -3.9 Q(Btu/h) 18760 9240 14110 9470 4650 2150 20100 9900 15120 10150 4980 2300 21440 10560 16130 10830 5310 2450 W 2250 830 1710 1150 560 250 2140 790 1620 1090 530 240 2030 750 1530 1030 500 230 20 -6.7 Q(Btu/h) 17710 8350 13320 8940 4390 2020 19100 9010 14370 9640 4730 2180 20490 9670 15420 10340 5070 2340 W 2250 770 1710 1150 560 250 2140 730 1620 1090 530 240 2030 690 1530 1030 500 230 15 -9.4 Q(Btu/h) 16720 7460 12580 8440 4140 1910 18200 8120 13690 9190 4510 2080 19680 8780 14800 9940 4880 2250 W 2250 700 1710 1150 560 250 2140 660 1620 1090 530 240 2030 620 1530 1030 500 230 10 -12.2 Q(Btu/h) 15600 6530 11740 7870 3860 1790 17200 7200 12940 8680 4260 1970 18800 7870 14140 9490 4660 2150 W 2250 620 1710 1150 560 250 2140 590 1620 1090 530 240 2030 560 1530 1030 500 230 5 -15.0 Q(Btu/h) 14430 5580 10860 7290 3570 1650 16200 6270 12190 8180 4010 1850 17970 6960 13520 9070 4450 2050 W 2250 550 1710 1150 560 250 2140 520 1620 1090 530 240 2030 490 1530 1030 500 230 0 -17.8 Q(Btu/h) 13190 5920 9930 6660 3260 1510 15200 6820 11440 7670 3760 1740 17210 7720 12950 8680 4260 1970 W 2210 820 1660 1120 550 250 2100 780 1580 1060 520 240 1990 740 1500 1000 490 230 -5 -20.6 Q(Btu/h) 11890 6170 8950 6010 2950 1360 14200 7370 10680 7170 3520 1620 16510 8570 12410 8330 4090 1880 W 2110 1100 1580 1060 530 240 2000 1040 1500 1010 500 230 1890 980 1420 960 470 220 -10 -23.3 Q(Btu/h) 10530 5460 7920 5310 2610 1200 13200 6850 9930 6660 3270 1510 15870 8240 11940 8010 3930 1820 W 2020 1050 1530 1030 510 230 1920 1000 1450 980 480 220 1820 950 1370 930 450 210 * Above data is for heating operation without any frost. OBD946_97 MUZ-FX15NLHZ Rated Q(Btu/h): 15000 1) COOLING W: 1020 Indoor W.B. 71°F / 21.7°C 67°F / 19.4°C 63°F / 17.2°C Outdoor D.B. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. (°F) (°C) 115 46.1 Q(Btu/h) 17240 13800 13220 9010 4990 3340 16330 12830 12520 8530 4720 3160 15340 11700 11770 8010 4440 2970 W 2590 1170 1930 1240 580 300 2440 1130 1820 1170 540 290 2320 1080 1730 1120 510 280 110 43.3 Q(Btu/h) 18000 14400 13800 9410 5210 3480 17050 13390 13070 8910 4930 3300 16020 12270 12280 8370 4640 3100 W 2530 1150 1880 1200 570 300 2390 1110 1780 1140 530 290 2270 1060 1690 1090 500 280 105 40.6 Q(Btu/h) 18750 15000 14380 9800 5420 3630 17760 13950 13620 9280 5130 3440 16690 12830 12800 8720 4830 3230 W 2470 1130 1840 1170 560 290 2330 1080 1740 1110 520 280 2220 1040 1650 1060 490 270 100 37.8 Q(Btu/h) 19460 15570 14920 10170 5630 3770 18430 14480 14130 9630 5330 3570 17320 13470 13280 9050 5010 3350 W 2400 1100 1790 1140 550 280 2270 1050 1690 1080 510 270 2160 1010 1600 1030 490 260 95 35.0 Q(Btu/h) 20170 16130 15460 10540 5830 3910 19100 15000 14640 9980 5520 3700 17950 14100 13760 9380 5190 3480 W 2330 1070 1740 1110 530 270 2200 1020 1640 1050 490 260 2090 970 1560 1000 470 250 90 32.2 Q(Btu/h) 20980 16660 16080 10960 6060 4070 19870 15600 15230 10380 5740 3850 18670 14630 14320 9750 5400 3620 W 2250 1030 1670 1070 500 260 2120 980 1580 1010 470 250 2020 940 1500 960 450 240 85 29.4 Q(Btu/h) 21780 17180 16690 11390 6300 4220 20630 16200 15810 10780 5960 4000 19380 15150 14860 10130 5610 3760 W 2160 990 1610 1030 480 250 2040 940 1520 970 450 240 1940 900 1440 930 430 230 80 26.7 Q(Btu/h) 22600 17780 17320 11810 6530 4380 21400 16800 16400 11180 6180 4150 20110 15750 15410 10500 5810 3900 W 2070 950 1530 980 460 240 1950 900 1450 930 430 230 1860 860 1380 890 410 220 75 23.9 Q(Btu/h) 23400 18380 17930 12230 6760 4530 22160 17400 16980 11580 6400 4290 20820 16350 15960 10880 6020 4030 W 1960 910 1460 930 440 230 1850 860 1380 880 410 220 1760 820 1310 840 390 210 70 21.1 Q(Btu/h) 24200 19010 18550 12650 6990 4690 22920 18000 17570 11980 6620 4440 21530 16910 16510 11260 6230 4170 W 1850 860 1390 890 420 220 1750 810 1310 840 390 210 1660 770 1240 800 370 200 65 18.3 Q(Btu/h) 20670 16240 15610 10330 5280 3210 19580 15380 14790 9780 5000 3040 18390 14450 13900 9190 4710 2860 W 3060 1420 2320 1540 800 470 2898 1340 2190 1450 740 450 2750 1270 2070 1380 700 430 60 15.6 Q(Btu/h) 20670 16240 15610 10330 5280 3210 19580 15380 14790 9780 5000 3040 18390 14450 13900 9190 4710 2860 W 3060 1420 2320 1540 800 470 2898 1340 2190 1450 740 450 2750 1270 2070 1380 700 430 55 12.8 Q(Btu/h) 20670 16240 15610 10330 5280 3210 19580 15380 14790 9780 5000 3040 18390 14450 13900 9190 4710 2860 W 3060 1420 2320 1540 800 470 2898 1340 2190 1450 740 450 2750 1270 2070 1380 700 430 50 10.0 Q(Btu/h) 20670 16240 15610 10330 5280 3210 19580 15380 14790 9780 5000 3040 18390 14450 13900 9190 4710 2860 W 3060 1420 2320 1540 800 470 2898 1340 2190 1450 740 450 2750 1270 2070 1380 700 430 45 7.2 Q(Btu/h) 20670 16240 15610 10330 5280 3210 19580 15380 14790 9780 5000 3040 18390 14450 13900 9190 4710 2860 W 3060 1420 2320 1540 800 470 2898 1340 2190 1450 740 450 2750 1270 2070 1380 700 430 40 4.4 Q(Btu/h) 20670 16240 15610 10330 5280 3210 19580 15380 14790 9780 5000 3040 18390 14450 13900 9190 4710 2860 W 3060 1420 2320 1540 800 470 2898 1340 2190 1450 740 450 2750 1270 2070 1380 700 430 35 1.7 Q(Btu/h) 20670 16240 15610 10330 5280 3210 19580 15380 14790 9780 5000 3040 18390 14450 13900 9190 4710 2860 W 3060 1420 2320 1540 800 470 2898 1340 2190 1450 740 450 2750 1270 2070 1380 700 430 30 -1.1 Q(Btu/h) 20670 16240 15610 10330 5280 3210 19580 15380 14790 9780 5000 3040 18390 14450 13900 9190 4710 2860 W 3060 1420 2320 1540 800 470 2898 1340 2190 1450 740 450 2750 1270 2070 1380 700 430 25 -3.9 Q(Btu/h) 20670 16240 15610 10330 5280 3210 19580 15380 14790 9780 5000 3040 18390 14450 13900 9190 4710 2860 W 3060 1420 2320 1540 800 470 2898 1340 2190 1450 740 450 2750 1270 2070 1380 700 430 20 -6.7 Q(Btu/h) 20670 16240 15610 10330 5280 3210 19580 15380 14790 9780 5000 3040 18390 14450 13900 9190 4710 2860 W 3060 1420 2320 1540 800 470 2898 1340 2190 1450 740 450 2750 1270 2070 1380 700 430 15 -9.4 Q(Btu/h) 20670 16240 15610 10330 5280 3210 19580 15380 14790 9780 5000 3040 18390 14450 13900 9190 4710 2860 W 3060 1420 2320 1540 800 470 2898 1340 2190 1450 740 450 2750 1270 2070 1380 700 430 * It may not reach the above capacities in low ambient temperatures. OBD946_98 MUZ-FX15NLHZ Rated Q(Btu/h): 16500 2) HEATING W: 1080 Indoor D.B. 78.8°F / 26.0°C 70°F / 21.1°C 59°F / 15.0°C Outdoor W.B. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. (°F) (°C) 65 18.3 Q(Btu/h) 35470 20610 26510 17940 8960 5840 36920 21450 27590 18670 9330 6080 38370 22290 28670 19400 9700 6320 W 2990 1230 2230 1510 760 500 2840 1170 2120 1430 720 470 2690 1110 2010 1350 680 440 60 15.6 Q(Btu/h) 33560 19500 25080 16980 8490 5540 35010 20340 26170 17710 8860 5780 36460 21180 27260 18440 9230 6020 W 2970 1220 2220 1510 760 500 2820 1160 2110 1430 720 470 2670 1100 2000 1350 680 440 55 12.8 Q(Btu/h) 31610 18360 23630 15980 7990 5210 33090 19220 24730 16730 8360 5450 34570 20080 25830 17480 8730 5690 W 2940 1200 2190 1490 740 480 2790 1140 2080 1410 700 460 2640 1080 1970 1330 660 440 50 10.0 Q(Btu/h) 29670 17240 22180 15010 7500 4890 31170 18110 23300 15770 7880 5140 32670 18980 24420 16530 8260 5390 W 2890 1180 2160 1460 740 480 2740 1120 2050 1390 700 460 2590 1060 1940 1320 660 440 45 7.2 Q(Btu/h) 27740 16120 20730 14030 7010 4570 29250 17000 21860 14790 7390 4820 30760 17880 22990 15550 7770 5070 W 2820 1160 2110 1420 720 460 2680 1100 2000 1350 680 440 2540 1040 1890 1280 640 420 43 6.1 Q(Btu/h) 26890 15620 20090 13590 6790 4880 28400 16500 21220 14350 7170 5150 29910 17380 22350 15110 7550 5420 W 2770 1140 2080 1400 700 290 2630 1080 1970 1330 660 280 2490 1020 1860 1260 620 270 40 4.4 Q(Btu/h) 26640 14930 19910 13460 6730 4380 28200 15800 21070 14250 7120 4640 29760 16670 22230 15040 7510 4900 W 2890 1130 2160 1460 740 480 2740 1070 2050 1390 700 460 2590 1010 1940 1320 660 440 35 1.7 Q(Btu/h) 26260 13740 19630 13270 6640 4330 27900 14600 20850 14100 7050 4600 29540 15460 22070 14930 7460 4870 W 3100 1090 2320 1570 790 520 2940 1030 2200 1490 750 490 2780 970 2080 1410 710 460 30 -1.1 Q(Btu/h) 25790 12650 19270 13030 6520 4250 27500 13490 20550 13900 6950 4530 29210 14330 21830 14770 7380 4810 W 3300 1030 2470 1660 830 550 3130 980 2340 1580 790 520 2960 930 2210 1500 750 490 25 -3.9 Q(Btu/h) 25380 11550 18970 12830 6410 4180 27200 12380 20330 13750 6870 4480 29020 13210 21690 14670 7330 4780 W 3500 970 2610 1770 880 580 3320 920 2480 1680 840 550 3140 870 2350 1590 800 520 20 -6.7 Q(Btu/h) 24850 10450 18570 12560 6280 4100 26800 11270 20030 13550 6770 4420 28750 12090 21490 14540 7260 4740 W 3700 900 2760 1860 940 610 3510 850 2620 1770 890 580 3320 800 2480 1680 840 550 15 -9.4 Q(Btu/h) 24350 9330 18190 12300 6160 4020 26500 10150 19800 13390 6700 4370 28650 10970 21410 14480 7240 4720 W 3900 820 2910 1970 980 640 3700 780 2760 1870 930 610 3500 740 2610 1770 880 580 10 -12.2 Q(Btu/h) 22090 8160 16500 11160 5580 3640 24350 9000 18190 12300 6150 4010 26610 9840 19880 13440 6720 4380 W 3540 740 2650 1800 910 590 3360 700 2520 1710 860 560 3180 660 2390 1620 810 530 5 -15.0 Q(Btu/h) 19770 6980 14770 9990 5000 3260 22200 7840 16580 11220 5610 3660 24630 8700 18390 12450 6220 4060 W 3180 640 2370 1600 800 530 3020 610 2250 1520 760 500 2860 580 2130 1440 720 470 0 -17.8 Q(Btu/h) 17620 7620 13160 8900 4440 2900 20300 8780 15160 10250 5120 3340 22980 9940 17160 11600 5800 3780 W 3060 1100 2280 1540 770 510 2900 1040 2160 1460 730 480 2740 980 2040 1380 690 450 -5 -20.6 Q(Btu/h) 15410 8130 11520 7790 3890 2540 18400 9710 13750 9300 4650 3030 21390 11290 15980 10810 5410 3520 W 2920 1540 2190 1490 740 480 2770 1460 2080 1410 700 460 2620 1380 1970 1330 660 440 -10 -23.3 Q(Btu/h) 13160 6940 9830 6650 3330 2170 16500 8700 12330 8340 4170 2720 19840 10460 14830 10030 5010 3270 W 2790 1470 2090 1410 710 460 2650 1400 1980 1340 670 440 2510 1330 1870 1270 630 420 * Above data is for heating operation without any frost. OBD946_99 MUZ-FX18NLHZ Rated Q(Btu/h): 17200 1) COOLING W: 1320 Indoor W.B. 71°F / 21.7°C 67°F / 19.4°C 63°F / 17.2°C Outdoor D.B. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. (°F) (°C) 115 46.1 Q(Btu/h) 19410 15820 14650 10080 5330 3340 18380 14710 13880 9550 5040 3160 17270 13420 13040 8980 4740 2970 W 2780 1520 2050 1340 610 300 2620 1470 1930 1270 580 290 2500 1400 1840 1200 550 280 110 43.3 Q(Btu/h) 20270 16510 15300 10520 5570 3480 19190 15360 14490 9970 5270 3300 18040 14070 13610 9370 4950 3100 W 2720 1490 2010 1300 600 300 2560 1440 1890 1240 570 290 2440 1380 1800 1180 540 280 105 40.6 Q(Btu/h) 21120 17200 15930 10970 5800 3630 20000 16000 15090 10390 5490 3440 18800 14710 14180 9760 5160 3230 W 2650 1460 1950 1270 580 290 2500 1400 1840 1210 550 280 2390 1350 1750 1150 530 270 100 37.8 Q(Btu/h) 21910 17850 16530 11380 6030 3770 20750 16600 15660 10780 5700 3570 19500 15440 14710 10130 5360 3350 W 2580 1430 1900 1240 560 280 2430 1360 1790 1180 540 270 2320 1310 1700 1120 520 260 95 35.0 Q(Btu/h) 22710 18490 17140 11790 6240 3910 21500 17200 16230 11170 5900 3700 20210 16170 15250 10500 5550 3480 W 2500 1390 1850 1200 540 270 2360 1320 1740 1140 520 260 2250 1260 1660 1080 500 250 90 32.2 Q(Btu/h) 23620 19090 17820 12270 6490 4070 22360 17890 16880 11620 6140 3850 21020 16770 15860 10920 5770 3620 W 2410 1340 1780 1160 520 260 2270 1270 1680 1100 500 250 2170 1220 1600 1040 480 240 85 29.4 Q(Btu/h) 24520 19690 18510 12730 6730 4220 23220 18580 17530 12060 6370 4000 21820 17370 16470 11330 5990 3760 W 2310 1290 1710 1100 500 250 2180 1220 1610 1050 480 240 2080 1170 1530 1000 460 230 80 26.7 Q(Btu/h) 25430 20380 19190 13210 6990 4380 24080 19270 18180 12510 6610 4150 22630 18060 17080 11760 6210 3900 W 2210 1230 1630 1060 480 240 2080 1170 1540 1010 460 230 1990 1120 1470 960 440 220 75 23.9 Q(Btu/h) 26340 21070 19880 13680 7230 4530 24940 19950 18830 12960 6840 4290 23440 18750 17690 12180 6430 4030 W 2100 1170 1550 1010 460 230 1980 1110 1460 960 440 220 1890 1060 1390 910 420 210 70 21.1 Q(Btu/h) 27250 21800 20570 14140 7480 4690 25800 20640 19480 13400 7080 4440 24250 19400 18300 12590 6660 4170 W 1990 1110 1480 960 430 220 1880 1050 1390 910 410 210 1790 1000 1320 860 390 200 65 18.3 Q(Btu/h) 23280 18620 17390 11740 5870 3420 22040 17630 16470 11130 5560 3240 20720 16570 15470 10460 5230 3040 W 3070 1710 2300 1550 780 450 2898 1620 2160 1470 740 430 2760 1540 2050 1390 700 410 60 15.6 Q(Btu/h) 23280 18620 17390 11740 5870 3420 22040 17630 16470 11130 5560 3240 20720 16570 15470 10460 5230 3040 W 3070 1710 2300 1550 780 450 2898 1620 2160 1470 740 430 2760 1540 2050 1390 700 410 55 12.8 Q(Btu/h) 23280 18620 17390 11740 5870 3420 22040 17630 16470 11130 5560 3240 20720 16570 15470 10460 5230 3040 W 3070 1710 2300 1550 780 450 2898 1620 2160 1470 740 430 2760 1540 2050 1390 700 410 50 10.0 Q(Btu/h) 23280 18620 17390 11740 5870 3420 22040 17630 16470 11130 5560 3240 20720 16570 15470 10460 5230 3040 W 3070 1710 2300 1550 780 450 2898 1620 2160 1470 740 430 2760 1540 2050 1390 700 410 45 7.2 Q(Btu/h) 23280 18620 17390 11740 5870 3420 22040 17630 16470 11130 5560 3240 20720 16570 15470 10460 5230 3040 W 3070 1710 2300 1550 780 450 2898 1620 2160 1470 740 430 2760 1540 2050 1390 700 410 40 4.4 Q(Btu/h) 23280 18620 17390 11740 5870 3420 22040 17630 16470 11130 5560 3240 20720 16570 15470 10460 5230 3040 W 3070 1710 2300 1550 780 450 2898 1620 2160 1470 740 430 2760 1540 2050 1390 700 410 35 1.7 Q(Btu/h) 23280 18620 17390 11740 5870 3420 22040 17630 16470 11130 5560 3240 20720 16570 15470 10460 5230 3040 W 3070 1710 2300 1550 780 450 2898 1620 2160 1470 740 430 2760 1540 2050 1390 700 410 30 -1.1 Q(Btu/h) 23280 18620 17390 11740 5870 3420 22040 17630 16470 11130 5560 3240 20720 16570 15470 10460 5230 3040 W 3070 1710 2300 1550 780 450 2898 1620 2160 1470 740 430 2760 1540 2050 1390 700 410 25 -3.9 Q(Btu/h) 23280 18620 17390 11740 5870 3420 22040 17630 16470 11130 5560 3240 20720 16570 15470 10460 5230 3040 W 3070 1710 2300 1550 780 450 2898 1620 2160 1470 740 430 2760 1540 2050 1390 700 410 20 -6.7 Q(Btu/h) 23280 18620 17390 11740 5870 3420 22040 17630 16470 11130 5560 3240 20720 16570 15470 10460 5230 3040 W 3070 1710 2300 1550 780 450 2898 1620 2160 1470 740 430 2760 1540 2050 1390 700 410 15 -9.4 Q(Btu/h) 23280 18620 17390 11740 5870 3420 22040 17630 16470 11130 5560 3240 20720 16570 15470 10460 5230 3040 W 3070 1710 2300 1550 780 450 2898 1620 2160 1470 740 430 2760 1540 2050 1390 700 410 * It may not reach the above capacities in low ambient temperatures. OBD946_100 MUZ-FX18NLHZ Rated Q(Btu/h): 17000 2) HEATING W: 1390 Indoor D.B. 78.8°F / 26.0°C 70°F / 21.1°C 59°F / 15.0°C Outdoor W.B. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. (°F) (°C) 65 18.3 Q(Btu/h) 37720 21240 28190 19050 9530 5960 39260 22100 29340 19830 9920 6200 40800 22960 30490 20610 10310 6440 W 3290 1580 2450 1650 820 520 3120 1500 2330 1570 780 490 2950 1420 2210 1490 740 460 60 15.6 Q(Btu/h) 35680 20090 26660 18020 9010 5640 37220 20960 27810 18800 9400 5880 38760 21830 28960 19580 9790 6120 W 3260 1570 2430 1640 820 520 3090 1490 2310 1560 780 490 2920 1410 2190 1480 740 460 55 12.8 Q(Btu/h) 33610 18930 25130 16990 8490 5310 35180 19810 26300 17780 8890 5560 36750 20690 27470 18570 9290 5810 W 3220 1550 2410 1630 820 520 3060 1470 2290 1550 780 490 2900 1390 2170 1470 740 460 50 10.0 Q(Btu/h) 31550 17760 23590 15940 7970 4980 33150 18660 24780 16750 8370 5230 34750 19560 25970 17560 8770 5480 W 3170 1530 2360 1600 800 510 3010 1450 2240 1520 760 480 2850 1370 2120 1440 720 450 45 7.2 Q(Btu/h) 29500 16600 22050 14910 7450 4660 31110 17510 23250 15720 7860 4910 32720 18420 24450 16530 8270 5160 W 3110 1500 2320 1570 790 500 2950 1420 2200 1490 750 470 2790 1340 2080 1410 710 440 43 6.1 Q(Btu/h) 28600 16100 21370 14450 7220 4880 30200 17000 22570 15260 7630 5150 31800 17900 23770 16070 8040 5420 W 3040 1460 2290 1550 770 290 2890 1390 2170 1470 730 280 2740 1320 2050 1390 690 270 40 4.4 Q(Btu/h) 28350 15380 21180 14320 7160 4480 30000 16280 22420 15160 7580 4740 31650 17180 23660 16000 8000 5000 W 3150 1440 2350 1590 800 510 2990 1370 2230 1510 760 480 2830 1300 2110 1430 720 450 35 1.7 Q(Btu/h) 27870 14170 20820 14080 7040 4410 29600 15050 22120 14960 7480 4680 31330 15930 23420 15840 7920 4950 W 3330 1390 2490 1680 840 530 3160 1320 2360 1590 800 500 2990 1250 2230 1500 760 470 30 -1.1 Q(Btu/h) 27470 13030 20530 13880 6940 4340 29300 13900 21900 14800 7400 4630 31130 14770 23270 15720 7860 4920 W 3510 1330 2620 1770 880 560 3330 1260 2490 1680 840 530 3150 1190 2360 1590 800 500 25 -3.9 Q(Btu/h) 26980 11900 20160 13630 6820 4260 28910 12750 21610 14610 7310 4570 30840 13600 23060 15590 7800 4880 W 3680 1250 2750 1860 930 580 3490 1190 2610 1770 880 550 3300 1130 2470 1680 830 520 20 -6.7 Q(Btu/h) 26480 10760 19780 13380 6680 4180 28560 11610 21340 14430 7210 4510 30640 12460 22900 15480 7740 4840 W 3860 1160 2890 1950 970 610 3660 1100 2740 1850 920 580 3460 1040 2590 1750 870 550 15 -9.4 Q(Btu/h) 25910 9610 19370 13090 6540 4090 28200 10460 21080 14250 7120 4450 30490 11310 22790 15410 7700 4810 W 4040 1050 3020 2040 1020 640 3830 1000 2870 1940 970 610 3630 950 2720 1840 920 580 10 -12.2 Q(Btu/h) 23490 8410 17560 11870 5930 3710 25900 9270 19360 13090 6540 4090 28310 10130 21160 14310 7150 4470 W 3780 950 2820 1910 950 590 3590 900 2680 1810 900 560 3400 850 2540 1710 850 530 5 -15.0 Q(Btu/h) 21020 7200 15710 10620 5310 3320 23600 8080 17640 11920 5960 3730 26180 8960 19570 13220 6610 4140 W 3530 830 2630 1780 900 560 3350 790 2500 1690 850 530 3170 750 2370 1600 800 500 0 -17.8 Q(Btu/h) 18750 8680 14010 9470 4740 2960 21600 10000 16140 10910 5460 3410 24450 11320 18270 12350 6180 3860 W 3340 1380 2500 1690 840 530 3170 1310 2370 1600 800 500 3000 1240 2240 1510 760 470 -5 -20.6 Q(Btu/h) 16330 9980 12200 8250 4130 2580 19500 11910 14570 9850 4930 3080 22670 13840 16940 11450 5730 3580 W 3150 1930 2350 1590 800 510 2990 1830 2230 1510 760 480 2830 1730 2110 1430 720 450 -10 -23.3 Q(Btu/h) 13960 8520 10430 7050 3530 2200 17500 10680 13080 8840 4420 2760 21040 12840 15730 10630 5310 3320 W 2960 1810 2200 1490 750 460 2810 1720 2090 1410 710 440 2660 1630 1980 1330 670 420 * Above data is for heating operation without any frost. OBD946_101 MUZ-FX24NLHZ Rated Q(Btu/h): 20800 1) COOLING W: 1560 Indoor W.B. 71°F / 21.7°C 67°F / 19.4°C 63°F / 17.2°C Outdoor D.B. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. (°F) (°C) 115 46.1 Q(Btu/h) 23930 19140 17730 11800 5610 2260 22660 17780 16790 11170 5310 2140 21300 16220 15780 10500 4990 2010 W 3960 1790 2920 1920 870 300 3740 1730 2750 1810 820 290 3570 1650 2620 1720 780 280 110 43.3 Q(Btu/h) 24980 19970 18520 12320 5870 2360 23660 18560 17530 11670 5550 2240 22240 17000 16480 10970 5220 2110 W 3880 1760 2860 1870 850 300 3660 1690 2690 1770 800 290 3490 1620 2560 1680 760 280 105 40.6 Q(Btu/h) 26030 20800 19300 12840 6110 2460 24650 19340 18270 12160 5780 2330 23170 17780 17170 11430 5430 2190 W 3780 1720 2790 1830 830 290 3570 1650 2630 1730 780 280 3410 1590 2500 1640 740 270 100 37.8 Q(Btu/h) 27010 21580 20030 13330 6340 2550 25580 20070 18960 12620 6000 2420 24040 18670 17820 11860 5640 2280 W 3680 1680 2720 1780 810 280 3470 1610 2560 1680 760 270 3310 1540 2440 1590 720 260 95 35.0 Q(Btu/h) 27980 22360 20740 13800 6560 2640 26500 20800 19640 13070 6210 2500 24910 19550 18460 12290 5840 2350 W 3570 1640 2640 1730 790 270 3370 1560 2480 1630 740 260 3220 1490 2360 1550 700 250 90 32.2 Q(Btu/h) 29100 23090 21580 14360 6830 2740 27560 21630 20430 13600 6460 2600 25900 20280 19200 12780 6070 2450 W 3450 1580 2540 1660 760 260 3250 1500 2390 1570 710 250 3100 1440 2280 1490 680 240 85 29.4 Q(Btu/h) 30220 23820 22400 14910 7090 2850 28620 22460 21210 14120 6710 2700 26900 21010 19930 13270 6310 2540 W 3310 1520 2430 1600 720 250 3120 1440 2290 1510 680 240 2980 1380 2180 1430 650 230 80 26.7 Q(Btu/h) 31340 24650 23240 15460 7360 2950 29680 23300 22000 14640 6960 2800 27890 21840 20680 13760 6540 2640 W 3160 1460 2330 1520 690 240 2980 1380 2190 1440 650 230 2840 1320 2080 1370 620 220 75 23.9 Q(Btu/h) 32460 25480 24060 16010 7610 3060 30740 24130 22780 15160 7200 2900 28890 22670 21410 14250 6770 2730 W 3000 1390 2210 1450 660 230 2830 1310 2080 1370 620 220 2700 1250 1980 1300 590 210 70 21.1 Q(Btu/h) 33580 26360 24890 16560 7870 3170 31800 24960 23570 15680 7450 3000 29890 23450 22150 14740 7010 2820 W 2850 1320 2100 1380 630 220 2690 1240 1980 1300 590 210 2570 1180 1880 1230 560 200 65 18.3 Q(Btu/h) 28680 22520 21440 14500 7260 3330 27160 21320 20300 13730 6870 3150 25530 20030 19080 12910 6460 2960 W 2940 1360 2200 1500 750 340 2774 1280 2070 1410 700 320 2650 1220 1970 1330 660 300 60 15.6 Q(Btu/h) 28680 22520 21440 14500 7260 3330 27160 21320 20300 13730 6870 3150 25530 20030 19080 12910 6460 2960 W 2940 1360 2200 1500 750 340 2774 1280 2070 1410 700 320 2650 1220 1970 1330 660 300 55 12.8 Q(Btu/h) 28680 22520 21440 14500 7260 3330 27160 21320 20300 13730 6870 3150 25530 20030 19080 12910 6460 2960 W 2940 1360 2200 1500 750 340 2774 1280 2070 1410 700 320 2650 1220 1970 1330 660 300 50 10.0 Q(Btu/h) 28680 22520 21440 14500 7260 3330 27160 21320 20300 13730 6870 3150 25530 20030 19080 12910 6460 2960 W 2940 1360 2200 1500 750 340 2774 1280 2070 1410 700 320 2650 1220 1970 1330 660 300 45 7.2 Q(Btu/h) 28680 22520 21440 14500 7260 3330 27160 21320 20300 13730 6870 3150 25530 20030 19080 12910 6460 2960 W 2940 1360 2200 1500 750 340 2774 1280 2070 1410 700 320 2650 1220 1970 1330 660 300 40 4.4 Q(Btu/h) 28680 22520 21440 14500 7260 3330 27160 21320 20300 13730 6870 3150 25530 20030 19080 12910 6460 2960 W 2940 1360 2200 1500 750 340 2774 1280 2070 1410 700 320 2650 1220 1970 1330 660 300 35 1.7 Q(Btu/h) 28680 22520 21440 14500 7260 3330 27160 21320 20300 13730 6870 3150 25530 20030 19080 12910 6460 2960 W 2940 1360 2200 1500 750 340 2774 1280 2070 1410 700 320 2650 1220 1970 1330 660 300 30 -1.1 Q(Btu/h) 28680 22520 21440 14500 7260 3330 27160 21320 20300 13730 6870 3150 25530 20030 19080 12910 6460 2960 W 2940 1360 2200 1500 750 340 2774 1280 2070 1410 700 320 2650 1220 1970 1330 660 300 25 -3.9 Q(Btu/h) 28680 22520 21440 14500 7260 3330 27160 21320 20300 13730 6870 3150 25530 20030 19080 12910 6460 2960 W 2940 1360 2200 1500 750 340 2774 1280 2070 1410 700 320 2650 1220 1970 1330 660 300 20 -6.7 Q(Btu/h) 28680 22520 21440 14500 7260 3330 27160 21320 20300 13730 6870 3150 25530 20030 19080 12910 6460 2960 W 2940 1360 2200 1500 750 340 2774 1280 2070 1410 700 320 2650 1220 1970 1330 660 300 15 -9.4 Q(Btu/h) 28680 22520 21440 14500 7260 3330 27160 21320 20300 13730 6870 3150 25530 20030 19080 12910 6460 2960 W 2940 1360 2200 1500 750 340 2774 1280 2070 1410 700 320 2650 1220 1970 1330 660 300 * It may not reach the above capacities in low ambient temperatures. OBD946_102 MUZ-FX24NLHZ Rated Q(Btu/h): 19800 2) HEATING W: 1500 Indoor D.B. 78.8°F / 26.0°C 70°F / 21.1°C 59°F / 15.0°C Outdoor W.B. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. Max. Rated 75% 50% 25% Min. (°F) (°C) 65 18.3 Q(Btu/h) 45220 24730 33920 22620 11310 6690 47060 25740 35300 23540 11770 6960 48900 26750 36680 24460 12230 7230 W 4090 1710 3060 2030 1020 600 3880 1620 2900 1930 970 570 3670 1530 2740 1830 920 540 60 15.6 Q(Btu/h) 42770 23400 32080 21390 10700 6320 44620 24410 33470 22320 11160 6590 46470 25420 34860 23250 11620 6860 W 4060 1700 3040 2030 1020 600 3850 1610 2890 1930 970 570 3640 1520 2740 1830 920 540 55 12.8 Q(Btu/h) 40290 22040 30220 20150 10080 5950 42170 23070 31630 21090 10550 6230 44050 24100 33040 22030 11020 6510 W 4010 1680 3010 2010 1010 600 3810 1590 2860 1910 960 570 3610 1500 2710 1810 910 540 50 10.0 Q(Btu/h) 37820 20680 28360 18910 9460 5590 39730 21730 29800 19870 9940 5870 41640 22780 31240 20830 10420 6150 W 3940 1640 2960 1980 990 590 3740 1560 2810 1880 940 560 3540 1480 2660 1780 890 530 45 7.2 Q(Btu/h) 35360 19340 26520 17690 8850 5230 37290 20390 27970 18650 9330 5510 39220 21440 29420 19610 9810 5790 W 3860 1610 2900 1930 970 570 3660 1530 2750 1830 920 540 3460 1450 2600 1730 870 510 43 6.1 Q(Btu/h) 34280 18750 25710 17140 8570 5210 36200 19800 27150 18100 9050 5500 38120 20850 28590 19060 9530 5790 W 3780 1580 2830 1890 940 340 3590 1500 2690 1790 890 320 3400 1420 2550 1690 840 300 40 4.4 Q(Btu/h) 33540 17910 25160 16770 8390 4960 35500 18960 26630 17750 8880 5250 37460 20010 28100 18730 9370 5540 W 3800 1560 2860 1910 960 570 3610 1480 2710 1810 910 540 3420 1400 2570 1710 860 510 35 1.7 Q(Btu/h) 32200 16490 24150 16100 8050 4750 34200 17520 25650 17100 8550 5050 36200 18550 27150 18100 9050 5350 W 3850 1510 2890 1930 970 570 3650 1430 2740 1830 920 540 3450 1350 2590 1730 870 510 30 -1.1 Q(Btu/h) 30940 15180 23210 15470 7740 4580 33000 16190 24750 16500 8250 4880 35060 17200 26290 17530 8760 5180 W 3890 1430 2910 1940 970 570 3690 1360 2760 1840 920 540 3490 1290 2610 1740 870 510 25 -3.9 Q(Btu/h) 29580 13860 22190 14800 7400 4380 31700 14850 23780 15860 7930 4690 33820 15840 25370 16920 8460 5000 W 3930 1350 2950 1970 990 590 3730 1280 2800 1870 940 560 3530 1210 2650 1770 890 530 20 -6.7 Q(Btu/h) 28230 12530 21180 14120 7060 4170 30450 13520 22850 15230 7610 4500 32670 14510 24520 16340 8160 4830 W 3970 1240 2970 1980 990 590 3770 1180 2820 1880 940 560 3570 1120 2670 1780 890 530 15 -9.4 Q(Btu/h) 26830 11190 20110 13410 6710 3960 29200 12180 21890 14590 7300 4310 31570 13170 23670 15770 7890 4660 W 4000 1140 3000 2000 1000 590 3800 1080 2850 1900 950 560 3600 1020 2700 1800 900 530 10 -12.2 Q(Btu/h) 25310 9800 18980 12660 6330 3740 27900 10800 20930 13960 6980 4120 30490 11800 22880 15260 7630 4500 W 4000 1020 3000 2000 1000 590 3800 970 2850 1900 950 560 3600 920 2700 1800 900 530 5 -15.0 Q(Btu/h) 23690 8380 17770 11850 5920 3500 26600 9410 19950 13300 6650 3930 29510 10440 22130 14750 7380 4360 W 3990 900 2990 1990 990 590 3790 850 2840 1890 940 560 3590 800 2690 1790 890 530 0 -17.8 Q(Btu/h) 21090 9370 15820 10550 5270 3120 24300 10800 18230 12150 6070 3590 27510 12230 20640 13750 6870 4060 W 3850 1460 2890 1930 970 570 3650 1390 2740 1830 920 540 3450 1320 2590 1730 870 510 -5 -20.6 Q(Btu/h) 18510 10200 13890 9260 4630 2740 22100 12180 16580 11050 5530 3270 25690 14160 19270 12840 6430 3800 W 3690 2030 2760 1830 920 540 3500 1930 2620 1740 870 510 3310 1830 2480 1650 820 480 -10 -23.3 Q(Btu/h) 15790 8700 11840 7900 3950 2340 19800 10910 14850 9900 4950 2930 23810 13120 17860 11900 5950 3520 W 3540 1950 2670 1780 880 530 3360 1850 2530 1690 840 500 3180 1750 2390 1600 800 470 * Above data is for heating operation without any frost. OBD946_103 HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN © Copyright 2024 MITSUBISHI ELECTRIC CORPORATION Issued: Nov. 2024. No. OBD946 REVISED EDITION-A Published Nov. 2024. No. OBD946 Made in Japan Specifications are subject to change without notice. CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 517 N MACLEOD AVENUE Permit #: 6628 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 00529901101501 DATE OF ISSUANCE. Scope of Work: 3/4 TON MINI SPLIT DUCTLESS INSTALL WITH 1 INDOOR Valuation: 6850.00 ZONE. OWNER APPLICANT CONTRACTOR NELSON ROBERT A & DEBORA K BLUE FLAME HEATING, AIR & BLUE FLAME HEATING AND AIR ELECTRIC 517 N MACLEOD 7116 220th Street Southwest 7116 220 ST SW ARLINGTON , WA 98223 Mountlake Terrace, WA, 98043 Mountlake Terrace, WA 98043 7472591791 425-771-7139 LIC: 601 837 949 EXP: 12/31/2025 LIC: BLUEFFH825RM EXP: 12/31/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC #: EXP: LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2021 STORIES: 2 CONST. TYPE: VB DWELLING UNITS: OCC GROUP: R-3; Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 8/20/2025 08/19/2025 Applicant Signature Date Building Official Date CONDITIONS Provide a 3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated, and the use of adhesive tapes are prohibited. Adhere to the approved equipment. Call for inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 08/19/2025 Processing/Technology $25.00 08/19/2025 Inspection $75.00 08/19/2025 Heat Pump - Condensing Unit $25.00 08/19/2025 Mechanical Base $25.00 08/19/2025 Credit Card Service $4.50 Total Due: $154.50 Total Payment: $154.50 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail Permit #: 6628 Permit Date: 07/17/25 Permit Type: RESIDENTIAL MECHANICAL Project Name: NELSON Applicant Name: BLUE FLAME HEATING, AIR & ELECTRIC Applicant Address: 7116 220th Street Southwest Applicant, City, State, Zip: Mountlake Terrace, WA, 98043 Contact: Jai Walker Phone: 7472591791 Email: jwalker@ipermitusa.com Scope of Work: 3/4 TON MINI SPLIT DUCTLESS INSTALL WITH 1 INDOOR ZONE. Valuation: 6850.00 Square Feet: 2394 Number of Stories: 2 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 08/20/2025 Permit Expires: 02/16/2026 Form Permit Type: RESIDENTIAL MECHANICAL Status: COMPLETE Assigned To: Kristin Foster Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 100 SINGLE 517 N MACLEOD NELSON ROBERT 00529901101501 FAMILY AVENUE A & DEBORA K RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License # BLUE FLAME RODNEY CONSTRUCTION 425-771-7139 7116 220 ST SW COA 601 837 949 HEATING AND AIR WALKER CONTRACTOR BLUE FLAME RODNEY CONSTRUCTION Labor & 425-771-7139 7116 220 ST SW BLUEFFH825RM HEATING AND AIR WALKER CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status R15. 08/29/2025 MECHANICAL 09/02/2025 09/02/2025 BUILDING Approved FINAL Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Heat Pump - Condensing Unit Enter # of units $25.00 Mechanical Base Permit Fee $25.00 Credit Card Service $4.50 Total $154.50 Attached Letters Date Letter Description 08/19/2025 Building Permit 07/17/2025 Web Form- Residential Mechanical Application Payments Date Paid By Description Payment Type Accepted By Amount XBP Conf: 07/17/2025 $150.00 237373139 07/17/2025 Jai Walker 237373139 $4.50 Outstanding Balance $0.00 Notes Date Note Created By: Emailed for an updated aerial view showing the distance from the outdoor unit to the property 07/17/2025 Kristin Foster line. Uploaded Files Date File Name 08/20/2025 27901384-20250820_BLD6628_IssuedPermit.pdf 08/19/2025 27889865-20250819_BLD6628_Site Plan.pdf 07/17/2025 09da3355443e54dd4fb55ff596f52c83_2025_0322_pm.pdf 07/17/2025 582fe6d9b2375f5a8b5706746ec099c1_mitsubishielectrictrane_muzfx06nlhz_service_manual.pdf 07/17/2025 c9b3732998c5fed336dfae1de99e89d9_12641972-residential_mechanical.pdf