HomeMy WebLinkAbout102 E Divison St_BLD4834_2025
CITY OF ARLINGTON INSPECTION CARD
No building construction shall be commenced until permit holder
INSPECTION RECORD SHALL or his agent has posted this Inspection Record Card in a
REMAIN AT JOB SITE conspicuous place on the premises.
OWNER: CONTRACTOR:
JOB ADDRESS: LOT NUMBER TYPE GROUP
NATURE of WORK:
USE of BUILDING:
PERMIT No: DATE ISSUED:
INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB
DEPARTMENT INSPECTION DATE(S) PASS FAIL INITIALS
FOOTING
BUILDING FOUNDATION
(360) 403-3417 UNDERFLOOR
SHEARWALL
PLUMBING (groundwork)
ROUGH PLUMBING
GAS PIPING
ROUGH HEATING & VENTILATION
FRAMING
INSULATION
WALLBOARD (SHEAR/RATED WALLS)
CEILING GRID
STRUCTURAL SLAB
CROSS CONNECTION CONTROL IN PREMISE
(360) 403-3417 GRADING
TEMPORARY TECSP
ASBUILTS APPROVED
MAINTENANCE BOND
STORM DRAINAGE SYSTEM
PAVING, SIGNAGE & MARKINGS
LANDSCAPING
CONDITIONS
ONSITE UTILITIES WATER
ONSITE UTILITIES SEWER
Sewer OFFSITE UTILITIES WATER
(360) 403-3508 OFFSITE UTILITIES SEWER
SEWER PRETREATMENT
Water CROSS CONNECTION CONTROL PREMISE
(360) 403-3526 SIDE SEWER/ CLEANOUT/FINAL
WATER SERVICE INSTALLATION
WATER SERVICE FINAL
(360) 403-3417 HYDRO/FLUSH
UNDERGROUND**INCL FDC
FIRE ALARM /AUTOMATIC SPRINKLER
HOOD SUPPRESSION SYSTEM
FINAL FIRE WALK-THROUGH
(360) 403-3417 FINAL INSPECTION
ALL SIGNATURE BLOCKS MUST BE COMPLETE
Inspection Results by Permit Number
Permit Number: BLD-4834
New Commercial
102 Division St, Arlington, WA 00000
Inspection Step Inspection Type Inspection Description Inspector Date Result
Inspections 2nd Floor Rough Michael Kolakowski 08/17/2023 Passed
Plumbing
Inspections 3rd Floor Rough Michael Kolakowski 08/17/2023 Passed
Plumbing
Inspections 4th Floor Rough Michael Kolakowski 08/17/2023 Passed
Plumbing
Inspections 2nd Floor Rough Michael Kolakowski 08/16/2023 Failed - Not Ready
Frame
Inspections 3rd Floor Fire Stopping Michael Kolakowski 08/16/2023 Partial Pass
Inspections Rough Plumbing Michael Kolakowski 08/08/2023 Passed
Inspections Rough Plumbing Michael Kolakowski 08/08/2023 Partial Pass
Inspections Insulation Michael Kolakowski 08/04/2023 Partial Pass
Inspections Firestopping Michael Kolakowski 08/04/2023 Partial Pass
Inspections Other Michael Kolakowski 08/02/2023 Partial Pass
Inspections Insulation Michael Kolakowski 07/25/2023 Partial Pass
Inspections Rough Plumbing Michael Kolakowski 07/13/2023 Passed
Inspections 1st Floor Shear Wall Michael Kolakowski 06/13/2023 Passed
Inspections 2nd Floor Shear Wall Michael Kolakowski 06/13/2023 Passed
Inspections 3rd Floor Shear Wall Michael Kolakowski 06/13/2023 Passed
Inspections 4th Floor Shear Wall Michael Kolakowski 06/13/2023 Passed
Inspections 1st Floor Shear Wall Michael Kolakowski 06/13/2023 Passed
Inspections 2nd Floor Shear Wall Michael Kolakowski 06/07/2023 Partial Pass
Inspections 3rd Floor Shear Wall Michael Kolakowski 06/07/2023 Partial Pass
Inspections 4th Floor Shear Wall Michael Kolakowski 06/07/2023 Partial Pass
Inspections 1st Floor Shear Wall Michael Kolakowski 06/07/2023 Partial Pass
Inspections 1st Floor Shear Wall Michael Kolakowski 06/01/2023 Failed - Not Ready
Inspection Results by Permit Number
Permit Number: BLD-4834
New Commercial
102 Division St, Arlington, WA 00000
Inspections 1st Floor Shear Wall Michael Kolakowski 05/26/2023 Failed - Code Violation
Inspections 2nd Floor Shear Wall Michael Kolakowski 05/26/2023 Failed - Code Violation
Inspections 3rd Floor Shear Wall Michael Kolakowski 05/26/2023 Failed - Code Violation
Inspections 4th Floor Shear Wall Michael Kolakowski 05/26/2023 Failed - Code Violation
Inspections Slab Michael Kolakowski 02/02/2023 Partial Pass
Inspections Foundation Reinforcing Michael Kolakowski 02/01/2023 Passed
Inspections Foundation Michael Kolakowski 02/01/2023 Passed
Footings/Rebar
Inspections 1st Floor Insulation Michael Kolakowski 02/01/2023 Passed
Inspections 1st Floor Final Energy Michael Kolakowski 02/01/2023 Passed
Inspections Underground Plumbing Michael Kolakowski 01/23/2023 Passed
Inspections Foundation Reinforcing Michael Kolakowski 11/18/2022 Passed
Inspections Footings Michael Kolakowski 11/09/2022 Partial Pass
Inspections Footings Michael Kolakowski 11/07/2022 Partial Pass
Inspections 35
Total Inspections: 35
CITY OF ARLINGTON INSPECTION CARD
No building construction shall be commenced until permit holder
INSPECTION RECORD SHALL or his agent has posted this Inspection Record Card in a
REMAIN AT JOB SITE conspicuous place on the premises.
OWNER: CONTRACTOR:
JOB ADDRESS: LOT NUMBER TYPE GROUP
NATURE of WORK:
USE of BUILDING:
PERMIT No: DATE ISSUED:
INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB
DEPARTMENT INSPECTION DATE(S) PASS FAIL INITIALS
FOOTING
BUILDING FOUNDATION
(360) 403-3417 UNDERFLOOR
SHEARWALL
PLUMBING (groundwork)
ROUGH PLUMBING
GAS PIPING
ROUGH HEATING & VENTILATION
FRAMING
INSULATION
WALLBOARD (SHEAR/RATED WALLS)
CEILING GRID
STRUCTURAL SLAB
CROSS CONNECTION CONTROL IN PREMISE
(360) 403-3417 GRADING
TEMPORARY TECSP
ASBUILTS APPROVED
MAINTENANCE BOND
STORM DRAINAGE SYSTEM
PAVING, SIGNAGE & MARKINGS
LANDSCAPING
CONDITIONS
ONSITE UTILITIES WATER
ONSITE UTILITIES SEWER
Sewer OFFSITE UTILITIES WATER
(360) 403-3508 OFFSITE UTILITIES SEWER
SEWER PRETREATMENT
Water CROSS CONNECTION CONTROL PREMISE
(360) 403-3526 SIDE SEWER/ CLEANOUT/FINAL
WATER SERVICE INSTALLATION
WATER SERVICE FINAL
(360) 403-3417 HYDRO/FLUSH
UNDERGROUND**INCL FDC
FIRE ALARM /AUTOMATIC SPRINKLER
HOOD SUPPRESSION SYSTEM
FINAL FIRE WALK-THROUGH
(360) 403-3417 FINAL INSPECTION
ALL SIGNATURE BLOCKS MUST BE COMPLETE
APPLICATION STATUS
☒ Revisions Required – Hold
Lou Tyler
Sr. Plans Examiner
Phone: 206-503-5948
1621 114th Ave SE, Ste 219
Bellevue WA 98004
DATE: 8/18/22
ltyler@safebuilt.com
Safebuiltbellevue@safebuilt.com
IMPORTANT REVISION SUBMITTAL INFORMATION
To Whom It May Concern:
A review for City of Arlington regarding BLD 4834 / PAISLEY LOFTS indicates that additional
information is necessary or further clarifications that will be required prior to approval of your project.
Please review the comments listed below and make corrections to the drawings as necessary.
Instructions for submitting Revisions
• Identify revised/added information by circling, noting, or otherwise consistently marking changes
on the plans.
• Please respond in writing to each comment by marking the attached list or creating a response
letter. Remember to indicate which plan sheet, detail, specification, or calculation shows the
requested information. Please send revisions to the attention of the plans examiner with the
building permit application number noted.
• Submit your revisions to Lou Whitford at Safebuilt as identified at top OR physically drop off
corrections at the City of Arlington with a copy of this letter. Either option is acceptable.
PLEASE NOTE:
These comments do not include those of other reviewing departments. If other city departments require
review of the proposed project, please be advised that the SAFEbuilt review and approval of the proposed
project does not, by itself, constitute approval of the permit and issuance.
Further review and correction may be necessary as a result of submitting this additional information. If
you have questions concerning the review of this project of the information contained in this letter, you
may contact SAFEbuilt as shown above.
Sincerely,
Lou Tyler
Senior Plans Examiner
1 | P a g e
COMMENTS ARE AS FOLLOWS;
1. ARCH ARCHITECT
• Plans were unsigned. Please sign all sheets of the architectural
plans and re-submit.
1.WATER WATER INTRUSION SPECIFIC SHEET
2. INTRU-
SION Please provide the following per RCW;
RCW 64.55.020 requires that any person applying for a building permit for
construction of a multiunit residential building or rehabilitative construction shall
submit building enclosure design documents to the appropriate building
department prior to the start of construction or rehabilitative construction of the
building enclosure. Please also note that per this section that nothing in RCW
64.55.005 through 64.55.090 requires a building department to review, approve,
or disapprove enclosure design documents.
Per RCW 64.55.010 (11) Such documents shall be stamped: "Stamped" means
bearing the stamp and signature of the responsible licensed architect or engineer
on the title page, and on every sheet of the documents, drawings, or
specifications, including modifications to the documents, drawings, and
specifications that become part of change orders or addenda to alter those
documents, drawings, or specifications.
During construction and prior to final occupancy the following shall occur:
RCW 64.55.030
Inspection required.
All multiunit residential buildings shall have the building enclosure inspected by a
qualified inspector during the course of initial construction and during
rehabilitative construction.
Cont….
2 | P a g e
2.
RCW 64.55.040
Inspectors—Qualifications.
(1) A qualified building enclosure inspector:
(a) Must be the architect or engineer of record or another person with
substantial and verifiable training and experience in building enclosure design
and construction;
(b) Shall be free from improper interference or influence relating to the
inspections; and
(c) May not be an employee, officer, or director of, nor have any pecuniary
interest in, the declarant, developer, association, or any party providing services
or materials for the project, or any of their respective affiliates, except that the
qualified inspector may be the architect or engineer who approved the building
enclosure design documents or the architect or engineer of record. The qualified
inspector may, but is not required to, assist with the preparation of such design
documents.
(2) Nothing in this section alters requirements for licensure of any architect,
engineer, or other professional, or alters the jurisdiction, authority, or scope of
practice of architects, engineers, other professionals, or general contractors.
RCW 64.55.050
Scope of inspection—Definition.
(1) Any inspection required by this chapter shall include, at a minimum, the
following:
(a) Water penetration resistance testing of a representative sample of windows
and window installations. Such tests shall be conducted according to industry
standards. Where appropriate, tests shall be conducted with an induced air
pressure difference across the window and window installation. Additional
testing is not required if the same assembly has previously been tested in situ
within the previous two years in the project under construction by the builder, by
another member of the construction team such as an architect or engineer, or by
an independent testing laboratory; and
(b) An independent periodic review of the building enclosure during the course
of construction or rehabilitative construction to ascertain whether the multiunit
residential building has been constructed, or the rehabilitative construction has
been performed, in substantial compliance with the building enclosure design
documents.
(2) Subsection (1)(a) of this section shall not apply to rehabilitative construction if
the windows and adjacent cladding are not altered in the rehabilitative
construction.
(3) "Project" means one or more parcels of land in a single ownership, which are
under development pursuant to a single land use approval or building permit,
where window installation is performed by the owner with its own forces, or by
the same general contractor, or, if the owner is contracting directly with trade
contractors, is performed by the same trade contractor.
Cont…
3 | P a g e
3. RCW 64.55.060
Certification—Certificate of occupancy.
Upon completion of an inspection required by this chapter, the qualified
inspector shall prepare and submit to the appropriate building department a
signed letter certifying that the building enclosure has been inspected during the
course of construction or rehabilitative construction and that it has been
constructed or reconstructed in substantial compliance with the building
enclosure design documents, as updated pursuant to RCW 64.55.020. The
building department shall not issue a final certificate of occupancy or other
equivalent final acceptance until the letter required by this section has been
submitted. The building department is not charged with and has no responsibility
for determining whether the building enclosure inspection is adequate or
appropriate to satisfy the requirements of this chapter.
INCLUDE SPECIAL INSPECTIONS REQUIRED
FOR WATER INTRUSION
4 | P a g e
City of Arlington
APPLICATION STATUS
☠Revisions Required – Hold
☠Initial Review ☠2nd Review ☠3rd Review
☠Approved With Conditions ☒ APPROVED
APPLICANT: PAISLEY LOFTS
EMAIL: gv@grandviewinc.net
PHONE # 360-435-7171
PERMIT #: BLD 4834
FROM: Lou Tyler PROJECT: PAISLEY LOFTS
EMAIL: ltyler@safebuilt.com ADDRESS: 102 DIVISION STREET
PHONE # 206-503-5948
DATE: 9/9/22
OCCUPANCY GROUP: B/R-2
CODES REVIEWED: TYPE OF CONSTRUCTION: V-A
☠2018 IRC ☒ 2018 IBC ☒ 2018 IMC NUMBER OF STORIES: 4 STRY
☒ 2018 UPC ☒ 2018 IFGC ☒ 2018 WSEC
SAFEbuilt Inc. has reviewed the above project documents for conformance to the provisions of
the 2018 International Building Code, Uniform Plumbing Code, International Fuel Gas Code,
International Mechanical Code, and International Energy Conservation Code as adopted and
amended by the State of Washington and the City of Arlington.
The permit referenced above is recommended for release of the reviewed construction
documents for this project. All outstanding comments have been addressed in an adequate
fashion and no comments remain.
Please do not hesitate to contact me if any assistance is needed with this process.
Sincerely,
Lou Tyler
Senior Plans Examiner
SAFEbuilt
1621 114th Ave SE, Ste 219
Safebuiltbellevue@safebuilt.com
ltyler@safebuilt.com
206-503-5948
1 | P a g e
Permit #: 4834
Permit Date: 06/29/22
Permit Type: COMMERCIAL BUILDING
Project Name: Paisley Lofts
Applicant Name: Grandview North LLC
Applicant Address: PO Box 159
Applicant, City, State, Zip: Arlington, WA 98223
Contact: Scott Wammack
Phone: 360-435-7171
Email: gv@grandviewinc.net
Scope of Work: Mixed-use building - 46 residential units
Valuation: 5178129.60
Square Feet: 34096
Number of Stories: 4
Construction Type: VA
Occupancy Group: B; Business
ID Code:
Permit Issued: 10/26/2022
Permit Expires: 04/24/2023
Form Permit Type: COMMERCIAL BUILDING
Status: COMPLETE
Assigned To: Ameresia Lawlis
Property
Parcel # Address Legal Description Owner Name Owner Phone Zoning
GRANDVIEW
00529900900300 102 E DIVISION STREET 140 MIXED-USE
NORTH LLC
Contractors
Contractor Primary Contact Phone Address Contractor Type License License #
CONSTRUCTION Labor &
Absolute Plumbing Paul Hooley 360-610-6141 PO Box 1445 ABSOLP*799MB
CONTRACTOR Industries
CONSTRUCTION
Absolute Plumbing Paul Hooley 360-610-6141 PO Box 1445 COA 603 305 333
CONTRACTOR
CONSTRUCTION Labor and
GRANDVIEW INC. 360-435-7171 P O BOX 159 GRANDHL848M7
CONTRACTOR Industries
Plan Reviews
Date Review Type Description Assigned To Review Status
COMMERCIAL
07/01/2022 BUILDING Approved
BUILDING
COMMERCIAL
07/01/2022 See Note PLANNING Approved
BUILDING
COMMERCIAL
07/25/2022 SafeBuilt Approved
BUILDING
Fees
Fee Description Notes Amount
Building Permit Table 4-1 $29,573.00
Building Plan Review Table 4-2 $20,484.58
Processing/Technology $25.00
State Surcharge - Commercial Commercial Only $25.00
Park - Mini MF Multi-family $10,950.00
Park - Community MF Multi-family $68,862.00
Traffic Mitigation - SF Single Family $83,875.00
Updated review fee cost =
Building Plan Review Table 4-2 $74.94
$20,409.64
Total $213,869.52
Attached Letters
Date Letter Description
10/25/2022 Building Permit
Payments
Date Paid By Description Payment Type Accepted By Amount
XBP Conf:
07/01/2022 $20,484.58
123580225
XBP Conf:
10/26/2022 $193,384.94
130834774
Outstanding Balance $0.00
Notes
Date Note Created By:
06/14/2024 TCO issued Kristin Foster
03/06/2024 Send correspondence to James at Grandview hulk@grandviewinc.net Kristin Foster
10/25/2022 Emailed Lou/Safebuilt for permit for signature Raelynn Jones
46 dwelling units
First floor - Commercial
09/15/2022 Ameresia Lawlis
Second floor - 18 dwelling units
Third floor - 14 dwelling units
Fourth floor - 14 dwelling units
09/09/2022 Received approved plans from Safebuilt Raelynn Jones
08/31/2022 Received revisions. Routed to Safebuilt for review. Raelynn Jones
08/18/2022 Notice of Corrections required received from Safebuilt Ameresia Lawlis
07/25/2022 Sent to Safebuilt for review per KO Raelynn Jones
526 N Olympic Ave - Business facing Olympic
102 E Division Suite 101 - 102 - Businesses facing Division
07/01/2022 102 E Division Suite 201-218 - Residential Ameresia Lawlis
102 E Division Suite 301-314 - Residential
102 E Division Suite 401-414 - Residential
Plan review fee paid based off originally valuation. Plan review fee calculated to $19,222.45 for
a difference of $1,262.13
07/01/2022 Ameresia Lawlis
Application states Valuation of $5,200,000; IBC calculates valuation at $4,846,313.60 per sq ft
listed on Arch plans
Uploaded Files
Date File Name
10/26/2022 13251884-20221026_4834_Issued Permit.pdf
07/01/2022 12182109-4834_Application.pdf
07/01/2022 12180461-4834_Architectural Plans.pdf
07/01/2022 12180462-4834_Mechanical Plans.pdf
07/01/2022 12180457-4834_Plumbing Plans.pdf
07/01/2022 12180458-4834_Site Plan.pdf
07/01/2022 12180459-4834_Structural Calcs.pdf
07/01/2022 12180460-4834_Structural Plans.pdf
APPLICATION STATUS
☒ Revisions Required – Hold
Lou Tyler
Sr. Plans Examiner
Phone: 206-503-5948
1621 114th Ave SE, Ste 219
Bellevue WA 98004
DATE: 8/18/22
ltyler@safebuilt.com
Safebuiltbellevue@safebuilt.com
IMPORTANT REVISION SUBMITTAL INFORMATION
To Whom It May Concern:
A review for City of Arlington regarding BLD 4834 / PAISLEY LOFTS indicates that additional
information is necessary or further clarifications that will be required prior to approval of your project.
Please review the comments listed below and make corrections to the drawings as necessary.
Instructions for submitting Revisions
• Identify revised/added information by circling, noting, or otherwise consistently marking changes
on the plans.
• Please respond in writing to each comment by marking the attached list or creating a response
letter. Remember to indicate which plan sheet, detail, specification, or calculation shows the
requested information. Please send revisions to the attention of the plans examiner with the
building permit application number noted.
• Submit your revisions to Lou Whitford at Safebuilt as identified at top OR physically drop off
corrections at the City of Arlington with a copy of this letter. Either option is acceptable.
PLEASE NOTE:
These comments do not include those of other reviewing departments. If other city departments require
review of the proposed project, please be advised that the SAFEbuilt review and approval of the proposed
project does not, by itself, constitute approval of the permit and issuance.
Further review and correction may be necessary as a result of submitting this additional information. If
you have questions concerning the review of this project of the information contained in this letter, you
may contact SAFEbuilt as shown above.
Sincerely,
Lou Tyler
Senior Plans Examiner
1 | P a g e
COMMENTS ARE AS FOLLOWS;
1. ARCH ARCHITECT
• Plans were unsigned. Please sign all sheets of the architectural
plans and re-submit.
1.WATER WATER INTRUSION SPECIFIC SHEET
2. INTRU-
SION Please provide the following per RCW;
RCW 64.55.020 requires that any person applying for a building permit for
construction of a multiunit residential building or rehabilitative construction shall
submit building enclosure design documents to the appropriate building
department prior to the start of construction or rehabilitative construction of the
building enclosure. Please also note that per this section that nothing in RCW
64.55.005 through 64.55.090 requires a building department to review, approve,
or disapprove enclosure design documents.
Per RCW 64.55.010 (11) Such documents shall be stamped: "Stamped" means
bearing the stamp and signature of the responsible licensed architect or engineer
on the title page, and on every sheet of the documents, drawings, or
specifications, including modifications to the documents, drawings, and
specifications that become part of change orders or addenda to alter those
documents, drawings, or specifications.
During construction and prior to final occupancy the following shall occur:
RCW 64.55.030
Inspection required.
All multiunit residential buildings shall have the building enclosure inspected by a
qualified inspector during the course of initial construction and during
rehabilitative construction.
Cont….
2 | P a g e
2.
RCW 64.55.040
Inspectors—Qualifications.
(1) A qualified building enclosure inspector:
(a) Must be the architect or engineer of record or another person with
substantial and verifiable training and experience in building enclosure design
and construction;
(b) Shall be free from improper interference or influence relating to the
inspections; and
(c) May not be an employee, officer, or director of, nor have any pecuniary
interest in, the declarant, developer, association, or any party providing services
or materials for the project, or any of their respective affiliates, except that the
qualified inspector may be the architect or engineer who approved the building
enclosure design documents or the architect or engineer of record. The qualified
inspector may, but is not required to, assist with the preparation of such design
documents.
(2) Nothing in this section alters requirements for licensure of any architect,
engineer, or other professional, or alters the jurisdiction, authority, or scope of
practice of architects, engineers, other professionals, or general contractors.
RCW 64.55.050
Scope of inspection—Definition.
(1) Any inspection required by this chapter shall include, at a minimum, the
following:
(a) Water penetration resistance testing of a representative sample of windows
and window installations. Such tests shall be conducted according to industry
standards. Where appropriate, tests shall be conducted with an induced air
pressure difference across the window and window installation. Additional
testing is not required if the same assembly has previously been tested in situ
within the previous two years in the project under construction by the builder, by
another member of the construction team such as an architect or engineer, or by
an independent testing laboratory; and
(b) An independent periodic review of the building enclosure during the course
of construction or rehabilitative construction to ascertain whether the multiunit
residential building has been constructed, or the rehabilitative construction has
been performed, in substantial compliance with the building enclosure design
documents.
(2) Subsection (1)(a) of this section shall not apply to rehabilitative construction if
the windows and adjacent cladding are not altered in the rehabilitative
construction.
(3) "Project" means one or more parcels of land in a single ownership, which are
under development pursuant to a single land use approval or building permit,
where window installation is performed by the owner with its own forces, or by
the same general contractor, or, if the owner is contracting directly with trade
contractors, is performed by the same trade contractor.
Cont…
3 | P a g e
3. RCW 64.55.060
Certification—Certificate of occupancy.
Upon completion of an inspection required by this chapter, the qualified
inspector shall prepare and submit to the appropriate building department a
signed letter certifying that the building enclosure has been inspected during the
course of construction or rehabilitative construction and that it has been
constructed or reconstructed in substantial compliance with the building
enclosure design documents, as updated pursuant to RCW 64.55.020. The
building department shall not issue a final certificate of occupancy or other
equivalent final acceptance until the letter required by this section has been
submitted. The building department is not charged with and has no responsibility
for determining whether the building enclosure inspection is adequate or
appropriate to satisfy the requirements of this chapter.
INCLUDE SPECIAL INSPECTIONS REQUIRED
FOR WATER INTRUSION
4 | P a g e
LEGEND
GENERAL NOTES
PRE-CON MEETING
APPLICABLE CODES
DRAWING INDEX
INCLUDED IN SET SHEETS WITH REVISIONS
DWG DESCRIPTION
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M0.0
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ENERGY CODE
NOTES
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M0.1
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
WSEC C406 EFFICIENCY PACKAGES
ENERGY CODE NOTES
2018 WSEC SECTION C406: ADDITIONAL ENERGY EFFICIENCY CREDIT REQUIREMENTS
≥
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M0.2
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
WHOLE HOUSE VENTILATION
NOTES
CALCULATIONS
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M0.3
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
SCHEDULES
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M0.4
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M2.0
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M2.1
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M2.2
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M3.0
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M3.1
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M3.2
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M4.0
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M4.1
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M5.0
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M5.1
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M5.2
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
M5.3
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
LEGEND
GENERAL NOTES
PRE-CON MEETING
APPLICABLE CODES
DRAWING INDEX
INCLUDED IN SET SHEETS WITH REVISIONS
DWG DESCRIPTION
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P0.0
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
CALCULATIONS
COMMERCIAL WATER PIPE SIZING
RESIDENTIAL WATER PIPE SIZING
COPPER PIPING
COPPER & PEX PIPING
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P0.1
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
SCHEDULES
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P0.2
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
SCHEDULES
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P0.3
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
C C C C C C
C C
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P1.0
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P2.0
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P2.1
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P2.2
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P3.0
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P3.1
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P3.2
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P3.3
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P3.4
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P3.5
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P4.0
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P4.1
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
ROBISON
ENGINEERING, INC
19401 40TH AVE W., SUITE 302
LYNNWOOD, WA 98036
P4.2
206-364-3343 tel
REI PROJECT NO.: 962-009
CONTACT: MIKE NELSON
6/21/22
04/24/22 Page 1 of 113
Structural Calculations
Page(s) Contents
1/15/2020
04/24/2022
Notes, Disclaimers:
ï‚· Bradley Engineering, Inc. takes no responsibility for items not specifically addressed within this report set.
ï‚· This report is valid only for the specific project shown above and herein.
B R A D L E Y
ENGINEERING, INC.
811 Yew St.
Bellingham, WA 98229
Ph. (360) 752-5795
(
3
6
0
)
7
5
2
-
04/24/22 Page 2 of 113
REFERENCE CODES & STANDARDS
êž International Code, 2018
êž Washington State Building Code, SBC 2018
êž National Design Specification for Wood Construction, NDS 2018
êž Building Code Requirements for Structural Concrete, ACI 318-19
êž Minimum Design Loads for Buildings and Other Structures, ASCE 7-16
êž Steel Construction Manual, 15th Edition, AISC 2015
· North American Standard for Cold-Formed Steel Structural Framing, AISI 2015 Ed.
TABLE 1: LATERAL DESIGN CRITERIA
Design Parameter Value Source
Seismic Design Category IBC 1613
Risk Category IBC Table 1604.5
Wind Exposure Category IBC 1609.4.3
Basic Wind Speed IBC Figure 1609.3(1)
Design Wind Load ASCE 7-16 28.6-1
TABLE 2: VERTICAL DESIGN CRITERIA
Load Source Live Load Dead Load
Roof Diaphragm 20 psf 15 psf
Floor Diaphragm 40 psf 12 psf
Decks & Balconies 60 psf 10 psf
Ground Snow Load -
Roof Snow Load -
Exterior Wall - 12 psf
Interior Wall - 10 psf
Interior Partition - 8 psf
TABLE 3: DEFLECTION LIMITS
Structural Member Live Snow Live + Dead
Roof (plaster ceiling) L/360 L/360 L/240
Roof (non-plaster ceiling) L/240 L/240 L/180
Roof (not supporting ceiling) L/180 L/180 L/120
Floor Members L/360 - L/240
Horizontal Deflection (any case) - - L/200
Farm Buildings & Greenhouses - - L/180
Long Spans (>20 feet) - - L/480
Sliding Glass Doors - - L/600
04/24/22 Page 3 of 113
ASCE 7 Hazards Report
Address: Standard: ASCE/SEI 7-16 Elevation: 109.93 ft (NAVD 88)
105 E Division St Risk Category: II Latitude: 48.19893
Arlington, Washington
Soil Class: D - Default (see Longitude: -122.126721
98223
Section 11.4.3)
Wind
Results:
Wind Speed 98 Vmph 110 MPH USED IN ANALYSIS
10-year MRI 68 Vmph
25-year MRI 74 Vmph
50-year MRI 79 Vmph
100-year MRI 84 Vmph
Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2
Date Accessed: Fri Apr 22 2022
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds
correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability =
0.00143, MRI = 700 years).
Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2.
https://asce7hazardtool.online/ Page 1 of 3 Fri Apr 22 2022
04/24/22 Page 4 of 113
Seismic
Site Soil Class: D - Default (see Section 11.4.3)
Results:
SS : 1.033 SD1 : N/A
S1 : 0.369 TL : 6
Fa : 1.2 PGA : 0.439
Fv : N/A PGA M : 0.527
SMS : 1.239 FPGA : 1.2
SM1 : N/A Ie : 1
SDS : 0.826 Cv : 1.307
Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8.
Data Accessed: Fri Apr 22 2022
Date Source: USGS Seismic Design Maps
https://asce7hazardtool.online/ Page 2 of 3 Fri Apr 22 2022
04/24/22 Page 5 of 113
Snow
Results:
2
Ground Snow Load, p : 17 lb/ft 25 PSF USED IN ANALYSIS
g
Elevation: 109.9 ft
Data Source:
Date Accessed: Fri Apr 22 2022
Statutory requirements of the Authority Having Jurisdiction are not included.
The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is†and without warranties of
any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers;
or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from
reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability,
currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement,
affiliation, relationship, or sponsorship of such third-party content by or from ASCE.
ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent
professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such
professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard.
In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors,
employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential
damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by
law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE 7 Hazard Tool.
https://asce7hazardtool.online/ Page 3 of 3 Fri Apr 22 2022
Title Block Line 1 Project Title:
04/24/22 Page 6 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 24 APR 2022, 2:31PM
File: Paisley Loft Calcs.ec6
ASCE Seismic Base Shear Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Risk Category Calculations per ASCE 7-16
ASCE 7-16, Page 4, Table 1.5-1
Risk Category of Building or Other Structure : "II" : All Buildings and other structures except those listed as Category I, III, and IV
Seismic Importance Factor = 1 ASCE 7-16, Page 5, Table 1.5-2
USER DEFINED Ground Motion ASCE 7-16 11.4.2
Max. Ground Motions, 5% Damping :
S = 1.033 g, 0.2 sec response
S
S1 = 0.3690 g, 1.0 sec response
Conforms to ASCE 7 Section 12.8.1.3: Regular structure with period of 0.5 s or less, SDS limited to max of 0.7*SDS or 1.0 for calculation of Cs.
Site Class, Site Coeff. and Design Category
Site Classification "D" : Shear Wave Velocity 600 to 1,200 ft/sec = D (Based on Testing) ASCE 7-16 Table 20.3-1
Site Coefficients Fa & Fv Fa = 1.01 ASCE 7-16 Table 11.4-1 & 11.4-2
(using straight-line interpolation from table values) Fv = 1.97
Maximum Considered Earthquake Acceleration S = Fa * Ss = 1.047 ASCE 7-16 Eq. 11.4-1
MS
S = Fv * S1 = 0.727 ASCE 7-16 Eq. 11.4-2
M1
Design Spectral Acceleration S = S * 2/3 = 0.698 ASCE 7-16 Eq. 11.4-3
DS MS
S = S * 2/3D1 M1 = 0.484 ASCE 7-16 Eq. 11.4-4
Seismic Design Category = D ASCE 7-16 Table 11.6-1 & -2
Resisting System ASCE 7-16 Table 12.2-1
Basic Seismic Force Resisting System . . . Bearing Wall Systems
15.Light-frame (wood) walls sheathed w/wood structural panels rated for shear resistance.
Response Modification Coefficient " R " = 6.50 Building height Limits :
System Overstrength Factor " Wo " = 3.00 Category "A & B" Limit: No Limit
Category "C" Limit: No Limit
Deflection Amplification Factor " Cd " = 4.00
Category "D" Limit: Limit = 65
NOTE! See ASCE 7-16 for all applicable footnotes. Category "E" Limit: Limit = 65
Category "F" Limit: Limit = 65
Lateral Force Procedure ASCE 7-16 Section 12.8.2
Equivalent Lateral Force Procedure
The "Equivalent Lateral Force Procedure" is being used according to the provisions of ASCE 7-16 12.8
Determine Building Period Use ASCE 12.8-7
Structure Type for Building Period Calculation : All Other Structural Systems
" Ct " value = 0.020 " hn " : Height from base to highest level = 50.0 ft
" x " value = 0.75
" Ta " Approximate fundemental period using Eq. 12.8-7 : Ta = Ct * (hn ^ x) = 0.376 sec
"TL" : Long-period transition period per ASCE 7-16 Maps 22-14 -> 22-17 6.000 sec
= 0.376 sec
" Cs " Response Coefficient ASCE 7-16 Section 12.8.1.1
S : Short Period Design Spectral ResponseDS = 0.698 From Eq. 12.8-2, Preliminary Cs = 0.107
" R " : Response Modification Factor = 6.50 From Eq. 12.8-3 & 12.8-4 , Cs need not exceed = 0.198
" I " : Seismic Importance Factor = 1 From Eq. 12.8-5 & 12.8-6, Cs not be less than = 0.031
User has selected ASCE 12.8.1.3 : Regular structure, Cs : Seismic Response Coefficient = = 0.1073
Less than 5 Stories and with T <<= 0.5 sec, SO Ss <= 1.5 for Cs calculation
Title Block Line 1 Project Title:
04/24/22 Page 7 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 24 APR 2022, 2:31PM
File: Paisley Loft Calcs.ec6
ASCE Seismic Base Shear Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Seismic Base Shear ASCE 7-16 Section 12.8.1
Cs = 0.1073 from 12.8.1.1 W ( see Sum Wi below ) = 1,274.60 k
Seismic Base Shear V = Cs * W = 136.82 k
Vertical Distribution of Seismic Forces ASCE 7-16 Section 12.8.3
" k " : hx exponent based on Ta = 1.00
Table of building Weights by Floor Level...
Level # Wi : Weight Hi : Height (Wi * Hi^k) Cvx Fx=Cvx * V Sum Story Shear Sum Story Moment
4 210.00 47.00 9,870.00 0.2811 38.46 38.46 0.00
3 297.60 36.00 10,713.60 0.3051 41.75 80.20 423.05
2 380.00 25.00 9,500.00 0.2705 37.02 117.22 1,305.29
1 387.00 13.00 5,031.00 0.1433 19.60 136.82 2,711.95
Sum Wi = 1,274.60 k Sum Wi * Hi = 35,114.60 k-ft Total Base Shear = 136.82k
Base Moment = 4,490.7k-ft
Diaphragm Forces : Seismic Design Category "B" to "F" ASCE 7-16 12.10.1.1
Level # Wi Fi Sum Fi Sum Wi Fpx : Calcd Fpx : Min Fpx : Max Fpx Dsgn. Force
4 210.00 38.46 38.46 210.00 38.46 29.31 58.61 38.46 38.46
3 297.60 41.75 80.20 507.60 47.02 41.53 83.06 47.02 47.02
2 380.00 37.02 117.22 887.60 50.18 53.03 106.06 53.03 53.03
1 387.00 19.60 136.82 1,274.60 41.54 54.01 108.01 54.01 54.01
Wpx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Weight at level of diaphragm and other structure elements attached to it.
Fi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Design Lateral Force applied at the level.
Sum Fi . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Sum of "Lat. Force" of current level plus all levels above
MIN Req'd Force @ Level . . . . . . . . . .0.20 * S * I * Wpx
DS
MAX Req'd Force @ Level . . . . . . . . . .0.40 * S * I * WpxDS
Fpx : Design Force @ Level . . . . . . . . . .Wpx * SUM(x->n) Fi / SUM(x->n) wi, x = Current level, n = Top Level
04/24/22 Page 8 of 113
Lateral AnalysisÂ
Address: 105Â EASTÂ DIVISIONÂ ST Date: 4/22/2022
Arlington, WA S/W User: L. Schweigert
Wind Analysis â€Â Calculation of Wind Loads
Inputs Â
Wind Speed, V 110 mph
Height, H 50 feet Reference ASCE 7â€16, Simplified Directional Procedure  (Ch 26)
Roof Angle 1 degrees
Exposure Category B
Horizontal Pressure Zone A
ASD Load Comb. Factor, 0.6
Topographic Factor, Kzt 1
Risk Category II
Risk Category:
I Low risk to human life in event of failure
II Most small residential structuresÂ
III Substantial risk to human life in event of failureÂ
IV Crucial to human life
Horizontal Pressure Zone:
A End zone of wall
B End zone of roof
C Interior zone of wall
D Interior zone of roof
Exposure Category:
B Areas closely surrounded by obstructions
C Open terrain and scattered obstructions
D Flat unobstructed areas or close to large body of water
Calculate λ (ASCE 7â€16 Figure 27.3.1) Calculate Ps30 (ASCE 7â€10 Figure 28.6â€1, V = 110 mph)
Height (ft) Exposure B Exposure C Exposure D Roof Angle Zone A Zone B Zone C Zone D
0 1.00 1.21 1.47 0 19.2 â€10 12.7 â€5.9
15 1.00 1.21 1.47 5 19.2 â€10 12.7 â€5.9
20 1.00 1.29 1.55 10 21.6 â€9 14.4 â€5.2
25 1.00 1.35 1.61 15 24.1 â€8 16 â€4.6
30 1.00 1.40 1.66 20 26.6 â€7 17.7 â€3.9
35 1.05 1.45 1.70 25 24.1 3.9 17.4 4.0
40 1.09 1.49 1.74 30 21.6 14.8 17.2 11.8
45 1.12 1.53 1.78 60 21.6 14.8 17.2 11.8
50 1.16 1.56 1.81
55 1.19 1.59 1.84 Ps30AÂ =Â 19.20 psf
60 1.22 1.62 1.87
Use ASD Load Combination 7
 = 1.16
Calculate simplified design wind pressure Apply ASD Load Combination Factor
* Kzt * = 22.27 psf = 0.6 P * = 13.36 psf
Design wind pressure shall not be less than 16 psf. (2018 IBC 1609.6.3)
PÂ =Â 16.00 psf
04/24/22 Page 9 of 113
Seismic Analysis
Address: 105Â EASTÂ DIVISIONÂ ST Date: 4/22/2022
S/W User: L. Schweigert
Calculation of Seismic LoadsÂ
ASCE 7â€16 12.14.8 Simplified Lateral Force Analysis Procedure:
An equivalent lateral force analysis shall consist of the application of equivalent static lateral forces to a linear mathematical
model of the structure. The lateral forces applied in each direction shall sum to a total seismic base shear given by Section
12.14.8.1 and shall be distributed vertically in accordance with Section 12.14.8.2. For the purpose of analysis, the structure
Comparison of Wind and Seismic Forces
Direction North/South East/WestÂ
Wind tributary length, ft 168.5 60
Wind tributary height, ft 50 50 Therefore, Seismic loads govern lateral analysisÂ
Wind tributary area, sq ft 8425 3000 for North/South resisting walls.Â
Wind Pressure, psf 16.00 16.00
Design wind  load, lb 134800.00 48000.00 Furthermore, Seismic loads govern lateralÂ
Design seismic Load, lb 136820 136820.0 analysis for East/West resisting walls.Â
Governed by: Seismic Seismic
04/24/22 Page 10 of 113
Seismic Analysis â€Â Calculation of Shear Wall Loads
Wall Location: First Floor Grid A
Description:
Shear Wall Calculations
Shear Force, 38300 lb
0 lb Load resisted by prescriptive/interior walls
38300 lb Load resisted by shear walls
525 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 3
Shear Wall, 52 ft Case 1: Conventional O.K.    PLF < 240
21 ft Case 2: SW4 & HDU4's 240 < PLF < 490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF < 980
0 Case 4: SW5 & HDU8's 980 < PLF < 1020
0 Case 5: Other sheathing methods required 1020 < PLF < 2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
73 ft
requirements are not met portal framing methods can be used.
Pres. Wall,Â
Summary: First Floor Grid C walls are case 3, conventional sheathing does not adequately resist lateralÂ
loads SW8 and HDU4 hold downs required.
insert appropriate text from CASE sheet
Wall Location: First Floor Grid F
Description:
Shear Wall Calculations
Story Shear, 14625 lb #N/A
0 lb Load resisted by prescriptive/interior walls
14625 lb Load resisted by shear walls
672 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 3
Shear Wall, 5 ft Case 1: Conventional O.K.    PLF < 240
13.3 ft Case 2: SW4 & HDU4's 240 < PLF < 490
3.5 ft Case 3: SW5 or SW8 & HDU4's 490 < PLF < 980
0 Case 4: SW5 & HDU8's 980 < PLF < 1020
0 Case 5: Other sheathing methods required 1020 < PLF < 2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
21.8 ft
requirements are not met portal framing methods can be used.
Pres. Wall,Â
Summary: First Floor Grid F walls are case 3, conventional sheathing does not adequately resist lateralÂ
loads SW8 and HDU4 hold downs required.
insert appropriate text from CASE sheet
04/24/22 Page 11 of 113
Seismic Analysis â€Â Calculation of Shear Wall Loads
Wall Location: First Floor Grid G
Description:
Shear Wall Calculations
Shear Force, 17914 lb
0 lb Load resisted by prescriptive/interior walls
17914 lb Load resisted by shear walls
569 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 3
Shear Wall, 31.5 ft Case 1: Conventional O.K.    PLF <240
0 Case 2: SW4 & HDU4's 240 < PLF <490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF <980
0 Case 4: SW5 & HDU8's 980 < PLF <1020
0 Case 5: Other sheathing methods required 1020 < PLF <2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
31.5 ft
requirements are not met portal framing methods can be used.
Pres. Wall,Â
Summary: First Floor Grid G walls are case 3, conventional sheathing does not adequately resist lateralÂ
loads SW8 and HDU4 hold downs required.insert appropriate text from CASE sheet
Wall Location: First Floor Grid J
Description:
Shear Wall Calculations
Story Shear, 37984 lb #N/A
0 lb Load resisted by prescriptive/interior walls
37984 lb Load resisted by shear walls
584 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 3
Shear Wall, 26.5 ft Case 1: Conventional O.K.    PLF <240
19.5 ft Case 2: SW4 & HDU4's 240 < PLF <490
19 ft Case 3: SW5 or SW8 & HDU4's 490 < PLF <980
0 Case 4: SW5 & HDU8's 980 < PLF <1020
0 Case 5: Other sheathing methods required 1020 < PLF <2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
65 ft
requirements are not met portal framing methods can be used.
Pres. Wall, 0
Summary: First Floor Grid J walls are case 3, conventional sheathing does not adequately resist lateralÂ
loads SW8 and HDU4 hold downs required.
insert appropriate text from CASE sheet
04/24/22 Page 12 of 113
Seismic Analysis â€Â Calculation of Shear Wall Loads
Wall Location: First Floor Grid L
Description:
Shear Wall Calculations
Shear Force, 18321 lb
0 lb Load resisted by prescriptive/interior walls
18321 lb Load resisted by shear walls
964 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 3
Shear Wall, 4.75 ft Case 1: Conventional O.K.    PLF <240
4.75 ft Case 2: SW4 & HDU4's 240 < PLF <490
4.75 ft Case 3: SW5 or SW8 & HDU2's 490 < PLF <980
4.75 ft Case 4: SW5 & HDU8's 980 < PLF <1020
0 Case 5: Other sheathing methods required 1020 < PLF <2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
19 ft
requirements are not met portal framing methods can be used.
Pres. Wall,Â
Summary: First Floor Grid L walls are case 3, conventional sheathing does not adequately resist lateralÂ
loads SW8 and HDU4 hold downs required.
insert appropriate text from CASE sheet
Wall Location: First Floor Grid 1
Description:
Shear Wall Calculations
Story Shear, 43600 lb
0 lb Load resisted by prescriptive/interior walls
43600 lb Load resisted by shear walls
474 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 2
Shear Wall, 92 ft Case 1: Conventional O.K.    PLF <240
0 Case 2: SW4 & HDU4's 240 < PLF <490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF <980
0 Case 4: SW5 & HDU8's 980 < PLF <1020
0 Case 5: Other sheathing methods required 1020 < PLF <2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
92 ft
requirements are not met portal framing methods can be used.
Pres. Wall, 0
Summary: First Floor Grid 1 walls are case 2, conventional sheathing does not adequately resist lateralÂ
loads. GW3 shear walls required on intrerior wall and SW4 and HDU4 hold downs required at exterior
insert appropriate text from CASE sheet
04/24/22 Page 13 of 113
Seismic Analysis â€Â Calculation of Shear Wall Loads
Wall Location: First Floor Grid 3
Description:
Shear Wall Calculations
Shear Force, 43600 lb
3600 lb Load resisted by prescriptive/interior walls
40000 lb Load resisted by shear walls
784 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 3
Shear Wall, 50 ft Case 1: Conventional O.K.    PLF <240
13.5 ft Case 2: SW4 & HDU4's 240 < PLF <490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF <980
0 Case 4: SW5 & HDU8's 980 < PLF <1020
0 Case 5: Other sheathing methods required 1020 < PLF <2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
51 ft
requirements are not met portal framing methods can be used.
Pres. Wall, 15 ft ft
Summary: First Floor Grid 3 walls are case 2, conventional sheathing does not adequately resist lateralÂ
loads SW4 and HDU2 hold downs required.insert appropriate text from CASE sheet
Wall Location: First floor grid 4
Description:
Shear Wall Calculations
Story Shear, 43600 lb
0 lb Load resisted by prescriptive/interior walls
43600 lb Load resisted by shear walls
946 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 3
Shear Wall, 21.3 ft Case 1: Conventional O.K.    PLF <240
12.5 ft Case 2: SW4 & HDU4's 240 < PLF <490
8 ft Case 3: SW5 or SW8 & HDU4's 490 < PLF <980
4.25 ft Case 4: SW5 & HDU8's 980 < PLF <1020
0 Case 5: Other sheathing methods required 1020 < PLF <2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
46.1 ft
requirements are not met portal framing methods can be used.
Pres. Wall, 0
Summary: Second Floor Grid 4 walls are case 2, conventional sheathing does not adequately resist lateralÂ
loads SW4 and MST48 strap hold downs required.
insert appropriate text from CASE sheet
04/24/22 Page 14 of 113
Seismic Analysis â€Â Calculation of Shear Wall Loads
Wall Location: Second Floor Gridline 1
Description:
Shear Wall Calculations
Shear Force, 39000 lb
0 lb Load resisted by prescriptive/interior walls
39000 lb Load resisted by shear walls
453 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 2
Shear Wall, 28.8 ft Case 1: Conventional O.K.    PLF <240
57.3 ft Case 2: SW4 & HDU4's 240 < PLF <490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF <980
0 Case 4: SW5 & HDU8's 980 < PLF <1020
0 Case 5: Other sheathing methods required 1020 < PLF <2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
86 ft
requirements are not met portal framing methods can be used.
Pres. Wall,Â
Summary: Second Floor Grid 1 walls are case 2, conventional sheathing does not adequately resist lateralÂ
loads SW4 and MST48 strap hold downs required.insert appropriate text from CASE sheet
Wall Location: Second Floor Grid 4
Description:
Shear Wall Calculations
Story Shear, 39000 lb
0 lb Load resisted by prescriptive/interior walls
39000 lb Load resisted by shear walls
448 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 2
Shear Wall, 87 ft Case 1: Conventional O.K.    PLF <240
0 Case 2: SW4 & HDU4's 240 < PLF <490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF <980
0 Case 4: SW5 & HDU8's 980 < PLF <1020
0 Case 5: Other sheathing methods required 1020 < PLF <2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
87 ft
requirements are not met portal framing methods can be used.
Pres. Wall, 0
Summary: Second Floor Grid 4 walls are case 2, conventional sheathing does not adequately resist lateralÂ
loads SW4 and MST48 strap hold downs required.
insert appropriate text from CASE sheet
04/24/22 Page 15 of 113
Seismic Analysis â€Â Calculation of Shear Wall Loads
Wall Location: Second Floor Gridline 2
Description:
Shear Wall Calculations
Shear Force, 39000 lb
0 lb Load resisted by prescriptive/interior walls
39000 lb Load resisted by shear walls
143 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 1
Shear Wall, 273 ft Case 1: Conventional O.K.    PLF < 240
0 Case 2: SW4 & HDU4's 240 < PLF < 490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF < 980
0 Case 4: SW5 & HDU8's 980 < PLF < 1020
0 Case 5: Other sheathing methods required 1020 < PLF < 2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
273 ft
requirements are not met portal framing methods can be used.
Pres. Wall, 0
Summary: Second floor grid B walls are Case 1, adequately braced by conventional sheathing. No specialÂ
shearwalls or holdâ€downs required. The lateral resistance provided by conventional sheating is structurallyÂ
insert appropriate text from CASE sheet
adequate to resist the tributary lateral loads imposed on them without additional lateral resistance providedÂ
by shearwalls and holdâ€downs/strapâ€ties, etc.
Wall Location: Second Floor Grid A
Description:
Shear Wall Calculations
Story Shear, 13950 lb
0 lb Load resisted by prescriptive/interior walls
13950 lb Load resisted by shear walls
457 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 2
Shear Wall, 30.5 ft Case 1: Conventional O.K.    PLF < 240
0 Case 2: SW4 & HDU4's 240 < PLF < 490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF < 980
0 Case 4: SW5 & HDU8's 980 < PLF < 1020
0 Case 5: Other sheathing methods required 1020 < PLF < 2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
30.5 ft
requirements are not met portal framing methods can be used.
Pres. Wall, 0
Summary: Second Floor Grid A walls are case 2, conventional sheathing does not adequately resist lateralÂ
loads SW4 and MST48 strap hold downs required.insert appropriate text from CASE sheet
04/24/22 Page 16 of 113
Seismic Analysis â€Â Calculation of Shear Wall Loads
Wall Location: Second Floor Grid D
Description:
Shear Wall Calculations
Shear Force, 39000 lb
19680 lb Load resisted by prescriptive/interior walls
19320 lb Load resisted by shear walls
483 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 2
Shear Wall, 20 ft Case 1: Conventional O.K.    PLF < 240
20 ft Case 2: SW4 & HDU4's 240 < PLF < 490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF < 980
0 Case 4: SW5 & HDU8's 980 < PLF < 1020
0 Case 5: Other sheathing methods required 1020 < PLF < 2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
40 ft
requirements are not met portal framing methods can be used.
Pres. Wall, 82 ft ft
Summary: Second Floor Grid 1 walls are case 2, conventional sheathing does not adequately resist lateralÂ
loads SW4 and MST48 strap hold downs required.
insert appropriate text from CASE sheet
Wall Location: SECOND FLOOR GRID I
Description:
Shear Wall Calculations
Story Shear, 43252 lb
19680 lb Load resisted by prescriptive/interior walls
23572 lb Load resisted by shear walls
449 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 2
Shear Wall, 27.3 ft Case 1: Conventional O.K.    PLF < 240
25.3 ft Case 2: SW4 & HDU4's 240 < PLF < 490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF < 980
0 Case 4: SW5 & HDU8's 980 < PLF < 1020
0 Case 5: Other sheathing methods required 1020 < PLF < 2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
52.5 ft
requirements are not met portal framing methods can be used.
Pres. Wall, 82 ft ft
Summary: Second Floor Grid I walls are case 2, conventional sheathing does not adequately resist lateralÂ
loads SW4 and MST48 strap hold downs required.insert appropriate text from CASE sheet
04/24/22 Page 17 of 113
Seismic Analysis â€Â Calculation of Shear Wall Loads
Wall Location: Second Floor Grid L
Description:
Shear Wall Calculations
Shear Force, 14696 lb
0 lb Load resisted by prescriptive/interior walls
14696 lb Load resisted by shear walls
459 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 2
Shear Wall, 3.5 ft Case 1: Conventional O.K.    PLF < 240
12.5 ft Case 2: SW4 & HDU4's 240 < PLF < 490
12.5 ft Case 3: SW5 or SW8 & HDU4's 490 < PLF < 980
3.5 ft Case 4: SW5 & HDU8's 980 < PLF < 1020
0 Case 5: Other sheathing methods required 1020 < PLF < 2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
32 ft
requirements are not met portal framing methods can be used.
Pres. Wall, 0
Summary: Second Floor Grid L walls are case 2, conventional sheathing does not adequately resist lateralÂ
loads SW4 and MST48 strap hold downs required.
insert appropriate text from CASE sheet
Wall Location: Third Floor Grid 1
Description:
Shear Wall Calculations
Story Shear, 26730 lb
0 lb Load resisted by prescriptive/interior walls
26730 lb Load resisted by shear walls
473 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 2
Shear Wall, 56.5 ft Case 1: Conventional O.K.    PLF < 240
0 Case 2: SW4 & HDU4's 240 < PLF < 490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF < 980
0 Case 4: SW5 & HDU8's 980 < PLF < 1020
0 Case 5: Other sheathing methods required 1020 < PLF < 2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
56.5 ft
requirements are not met portal framing methods can be used.
Pres. Wall, 0
Summary: Third Floor Grid 1 walls are case 2, conventional sheathing does not adequately resist lateralÂ
loads SW4 and MST48 strap hold downs required.insert appropriate text from CASE sheet
04/24/22 Page 18 of 113
Seismic Analysis â€Â Calculation of Shear Wall Loads
Wall Location: Third Floor Grid 4
Description:
Shear Wall Calculations
Shear Force, 26730 lb
0 lb Load resisted by prescriptive/interior walls
26730 lb Load resisted by shear walls
374 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 2
Shear Wall, 71.5 ft Case 1: Conventional O.K.    PLF < 240
0 Case 2: SW4 & HDU4's 240 < PLF < 490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF < 980
0 Case 4: SW5 & HDU8's 980 < PLF < 1020
0 Case 5: Other sheathing methods required 1020 < PLF < 2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
71.5 ft
requirements are not met portal framing methods can be used.
Pres. Wall, 0
Summary: Second Floor Grid 4 walls are case 2, conventional sheathing does not adequately resist lateralÂ
loads SW4 and MST48 strap hold downs required.
insert appropriate text from CASE sheet
Wall Location: Third Floor Grid A
Description:
Shear Wall Calculations
Story Shear, 11682 lb
0 lb Load resisted by prescriptive/interior walls
11682 lb Load resisted by shear walls
477 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 2
Shear Wall, 24.5 ft Case 1: Conventional O.K.    PLF < 240
0 Case 2: SW4 & HDU4's 240 < PLF < 490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF < 980
0 Case 4: SW5 & HDU8's 980 < PLF < 1020
0 Case 5: Other sheathing methods required 1020 < PLF < 2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
24.5 ft
requirements are not met portal framing methods can be used.
Pres. Wall, 0
Summary: Third Floor Grid A walls are case 2, conventional sheathing does not adequately resist lateralÂ
loads SW4 and MST48 strap hold downs required.insert appropriate text from CASE sheet
04/24/22 Page 19 of 113
Seismic Analysis â€Â Calculation of Shear Wall Loads
Wall Location: Third Floor Grid D
Description:
Shear Wall Calculations
Shear Force, 32888 lb
0 lb Load resisted by prescriptive/interior walls
32888 lb Load resisted by shear walls
272 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 2
Shear Wall, 40 ft Case 1: Conventional O.K.    PLF < 240
81 ft Case 2: SW4 & HDU4's 240 < PLF < 490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF < 980
0 Case 4: SW5 & HDU8's 980 < PLF < 1020
0 Case 5: Other sheathing methods required 1020 < PLF < 2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
121 ft
requirements are not met portal framing methods can be used.
Pres. Wall, 0
Summary: Third Floor Grid D walls are case 2, conventional sheathing does not adequately resist lateralÂ
loads SW4 and MST48 strap hold downs required.
insert appropriate text from CASE sheet
Wall Location: Third Floor Grid J
Description:
Shear Wall Calculations
Story Shear, 26074 lb
0 lb Load resisted by prescriptive/interior walls
26074 lb Load resisted by shear walls
423 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 2
Shear Wall, 21 ft Case 1: Conventional O.K.    PLF < 240
16.3 ft Case 2: SW4 & HDU4's 240 < PLF < 490
4.33 ft Case 3: SW5 or SW8 & HDU4's 490 < PLF < 980
20 ft Case 4: SW5 & HDU8's 980 < PLF < 1020
0 Case 5: Other sheathing methods required 1020 < PLF < 2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted inÂ
accordance with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
61.7 ft
requirements are not met portal framing methods can be used.
Pres. Wall,Â
Summary: Third Floor Grid J walls are case 2, conventional sheathing does not adequately resist lateralÂ
loads SW4 and MST48 strap hold downs required.insert appropriate text from CASE sheet
04/24/22 Page 20 of 113
Seismic Analysis â€Â Calculation of Shear Wall Loads
Wall Location: Forth Floor Grid 1
Description:
Shear Wall Calculations
Shear Force, 12833 lb
0 lb Load resisted by prescriptive/interior walls
12833 lb Load resisted by shear walls
227 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 1
Shear Wall, 56.5 ft Case 1: Conventional O.K.    PLF < 240
0 Case 2: SW4 & HDU4's 240 < PLF < 490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF < 980
0 Case 4: SW5 & HDU8's 980 < PLF < 1020
0 Case 5: Other sheathing methods required 1020 < PLF < 2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted in accordanceÂ
with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
56.5 ft
requirements are not met portal framing methods can be used.
Pres. Wall, 0
Summary: Fourth floor grid 1 walls are Case 1, adequately braced by conventional sheathing. No specialÂ
shearwalls or holdâ€downs required. The lateral resistance provided by conventional sheating is structurallyÂ
insert appropriate text from CASE sheet
adequate to resist the tributary lateral loads imposed on them without additional lateral resistance providedÂ
by shearwalls and holdâ€downs/strapâ€ties, etc.
Wall Location: Fourh Floor Grid A
Description:
Shear Wall Calculations
Story Shear, 5704 lb
0 lb Load resisted by prescriptive/interior walls
5704 lb Load resisted by shear walls
233 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 1
Shear Wall, 24.5 ft Case 1: Conventional O.K.    PLF < 240
0 Case 2: SW4 & HDU4's 240 < PLF < 490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF < 980
0 Case 4: SW5 & HDU8's 980 < PLF < 1020
0 Case 5: Other sheathing methods required 1020 < PLF < 2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted in accordanceÂ
with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
24.5 ft
requirements are not met portal framing methods can be used.
Pres. Wall,Â
Summary: Fourth floor grid A walls are Case 1, adequately braced by conventional sheathing. No specialÂ
shearwalls or holdâ€downs required. The lateral resistance proviinsert appropriate text from CASE sheetded by conventional sheating is structurallyÂ
adequate to resist the tributary lateral loads imposed on them without additional lateral resistance providedÂ
by shearwalls and holdâ€downs/strapâ€ties, etc.
04/24/22 Page 21 of 113
Seismic Analysis â€Â Calculation of Shear Wall Loads
Wall Location: Forth Floor Grid D
Description:
Shear Wall Calculations
Shear Force, 15827 lb
0 lb Load resisted by prescriptive/interior walls
15827 lb Load resisted by shear walls
131 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 1
Shear Wall, 40 ft Case 1: Conventional O.K.    PLF < 240
81 ft Case 2: SW4 & HDU4's 240 < PLF < 490
0 Case 3: SW5 or SW8 & HDU4's 490 < PLF < 980
0 Case 4: SW5 & HDU8's 980 < PLF < 1020
0 Case 5: Other sheathing methods required 1020 < PLF < 2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted in accordanceÂ
with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
121 ft
requirements are not met portal framing methods can be used.
Pres. Wall, 0
Summary: Fourth floor grid D walls are Case 1, adequately braced by conventional sheathing. No specialÂ
shearwalls or holdâ€downs required. The lateral resistance provided by conventional sheating is structurallyÂ
insert appropriate text from CASE sheet
adequate to resist the tributary lateral loads imposed on them without additional lateral resistance providedÂ
by shearwalls and holdâ€downs/strapâ€ties, etc.
Wall Location: Fourh Floor Grid J
Description:
Shear Wall Calculations
Story Shear, 11977 lb
0 lb Load resisted by prescriptive/interior walls
11977 lb Load resisted by shear walls
194 plf Shear Wall Load (pounds per length foot)
Resisting Shear Wall (ft) Shear Wall Case 1
Shear Wall, 21 ft Case 1: Conventional O.K.    PLF < 240
16.3 ft Case 2: SW4 & HDU4's 240 < PLF < 490
4.33 ft Case 3: SW5 or SW8 & HDU4's 490 < PLF < 980
20 ft Case 4: SW5 & HDU8's 980 < PLF < 1020
0 Case 5: Other sheathing methods required 1020 < PLF < 2435
0 Case 6: Shear capacity for double sided wall exceeded 2435 < PLF
0
0 Note: Shear nominal capacities taken from SDPWS Table 4.3 and adjusted in accordanceÂ
with SPDWS Section 4.3.  Shear wall aspect ration shall not exceed 3.5:1. IfÂ
61.7 ft
requirements are not met portal framing methods can be used.
Pres. Wall,Â
Summary: Fourth floor grid J walls are Case 1, adequately braced by conventional sheathing. No specialÂ
shearwalls or holdâ€downs required. The lateral resistance proviinsert appropriate text from CASE sheetded by conventional sheating is structurallyÂ
adequate to resist the tributary lateral loads imposed on them without additional lateral resistance providedÂ
by shearwalls and holdâ€downs/strapâ€ties, etc.
04/24/22 Page 22 of 113
Seismic Analysis â€Â Calculation of Shear Wall Loads
Wall Location: Remaining Walls
Description:
Summary: Remaining walls are adequately braced by conventional sheathing (not necessarily prescriptive")Â
by inspection. No special shearwalls or holdâ€downs required. The lateral resistance provided byÂ
conventional sheating is structurally adequate to resist the tributary lateral loads imposed on them withoutÂ
additional lateral resistance provided by shearwalls and holdâ€downs/strapâ€ties, etc.
JOB SUMMARY REPORT
04/24/22 Paisley Lofts Page 23 of 113
Level
Member Name Results Current Solution Comments
Level 2 Joists over big office Passed 1 piece(s) 11 7/8" TJI® 360 @ 16" OC Web Stiffeners
Required
Level 2 Joists over west parking Passed 1 piece(s) 11 7/8" TJI® 560 @ 16" OC Cantilever
Reinforcement (PB1)
Required
Level 2 Joists over Small office Passed 1 piece(s) 11 7/8" TJI® 360 @ 16" OC Web Stiffeners
break rm Required
Level 2 Joists over Small office at Passed 1 piece(s) 11 7/8" TJI® 360 @ 16" OC Cantilever
cantilever Reinforcement (E3)
Required
Level 2 joists over west parking, Passed 1 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam® LVL @ 16" OC
north cant.
Level 3 Rooftop Deck Joists Passed 1 piece(s) 11 7/8" TJI® 360 @ 16" OC
Level 3 & 4 Floor Joists Passed 1 piece(s) 11 7/8" TJI® 210 @ 16" OC
Roof: Joist Passed 1 piece(s) 11 7/8" TJI® 210 @ 24" OC
Roof: Joist with line load Passed 1 piece(s) 11 7/8" TJI® 210 @ 24" OC
ForteWEB Software Operator Job Notes 4/24/2022 9:38:36 PM
UTC
Luke Schweigert
Bradley Engineering Inc. ForteWEB
v3.2
(360) 510-9514 File Name: Paisley
Lofts
luke@bradleyengineeringinc.com
Page
1 / 13
MEMBER REPORT PASSED
04/24/22 Page 24 of 113
Level, Level 2 Joists over big office
1 piece(s) 11 7/8" TJI® 360 @ 16" OC
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) System : Floor
Member Type : Joist
Member Reaction (lbs) 1425 @ 12' 11 1/2" 1425 (3.17") Passed (100%) 1.00 1.0 D + 1.0 L (All Spans)
Building Use : Residential
Shear (lbs) 1425 @ 12' 11 1/2" 1705 Passed (84%) 1.00 1.0 D + 1.0 L (All Spans)
Building Code : IBC
2015
Moment (Ft-lbs) 5241 @ 8' 9" 6180 Passed (85%) 1.00 1.0 D + 1.0 L (All Spans) Design Methodology
: ASD
Live Load Defl. (in) 0.233 @ 7' 15/16" 0.313 Passed (L/643) -- 1.0 D + 1.0 L (All Spans)
Total Load Defl. (in) 0.342 @ 7' 11/16" 0.625 Passed (L/439) -- 1.0 D + 1.0 L (All Spans)
TJ-Proâ„¢ Rating 56 40 Passed -- --
• Deflection criteria: LL (L/480) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge™ Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-Pro™ Rating include: None.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Hanger on steel 1.75" /
5.50" Hanger¹ 344 681 1025 See note ¹
1.75" ²
2 - Hanger on steel 3.17" /
5.50" Hanger¹ 469 995 1464 See note ¹
1.75" ²
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• ¹ See Connector grid below for additional information and/or requirements.
• ² Required Bearing Length / Required Bearing Length with Web Stiffeners
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu) 3' 10" o/c
Bottom Edge (Lu) 12' 6" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
•Maximum allowable bracing intervals based on applied load.
Connector: Simpson Strong-Tie
Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories
1 - Top Mount Hanger BA2.37/11.88 3.00" 6-PDPAT-62KP N/A 2-10dx1.5
2 - Top Mount Hanger HB2.31X H=11.813 4.00" 4-1/8 WELD N/A 10-10dx1.5 Web Stiffeners
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Dead Floor Live
Vertical Loads Location Spacing (0.90) (1.00) Comments
1 - Uniform (PSF) 0 to 13' 5" 16" 24.0 40.0 Default Load
2 - Point (PLF) 8' 9" 16" 288.0 720.0
ForteWEB Software Operator Job Notes 4/24/2022 9:38:36 PM
UTC
Luke Schweigert
Bradley Engineering Inc. ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
(360) 510-9514 File Name: Paisley
Lofts
luke@bradleyengineeringinc.com
Page
2 / 13
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims
any other warranties04/24/22 Page 25 of 113
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer
of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software.
Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation
reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator Job Notes 4/24/2022 9:38:36 PM
UTC
Luke Schweigert
Bradley Engineering Inc. ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
(360) 510-9514 File Name: Paisley
Lofts
luke@bradleyengineeringinc.com
Page
3 / 13
MEMBER REPORT PASSED
04/24/22 Page 26 of 113
Level, Level 2 Joists over west parking
1 piece(s) 11 7/8" TJI® 560 @ 16" OC
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) System : Floor
Member Type : Joist
Member Reaction (lbs) 2143 @ 21' 1/2" 3455 (5.25") Passed (62%) 1.00 1.0 D + 1.0 L (All Spans)
Building Use : Residential
Shear (lbs) 1043 @ 21' 4 1/2" 2050 Passed (51%) 1.00 1.0 D + 1.0 L (All Spans)
Building Code : IBC
2015
Moment (Ft-lbs) -3928 @ 21' 1/2" 7125 Passed (55%) 1.00 1.0 D + 1.0 L (All Spans) Design Methodology
: ASD
Live Load Defl. (in) 0.347 @ 10' 8 1/2" 0.517 Passed (L/714) -- 1.0 D + 1.0 L (Alt Spans)
Total Load Defl. (in) 0.290 @ 25' 7 1/2" 0.458 Passed (2L/380) -- 1.0 D + 1.0 L (Alt Spans)
TJ-Proâ„¢ Rating 44 40 Passed -- --
• Deflection criteria: LL (L/480) and TL (L/240).
• Overhang deflection criteria: LL (2L/480) and TL (2L/240).
• Moment capacity over cantilever support 2 has been reduced by 25% to lessen the effects of buckling.
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge™ Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-Pro™ Rating include: 5/8" Gypsum ceiling, bridging or blocking at max. 8' o.c., Pour Flooring Overlay.
• Permanent bracing at third points In the back span or a direct applied ceiling over the entire back span length is required at the Right end of the member. See literature
detail (PB1) For clarification.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Stud wall - DF 5.50" 4.25" 1.75" 203 571/-45 774/-45 1 1/4" Rim Board
2 - Plate on steel - DF 8.00" 8.00" 3.50" 1191 952 2143 Blocking
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu) 9' 11" o/c
Bottom Edge (Lu) 8' 11" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
•Maximum allowable bracing intervals based on applied load.
Dead Floor Live
Vertical Loads Location Spacing (0.90) (1.00) Comments
1 - Uniform (PSF) 0 to 25' 7 1/2" 16" 24.0 40.0 Default Load
2 - Point (PLF) 25' 6" 16" 430.0 80.0
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims
any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer
of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software.
Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation
reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator Job Notes 4/24/2022 9:38:36 PM
UTC
Luke Schweigert
Bradley Engineering Inc. ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
(360) 510-9514 File Name: Paisley
Lofts
luke@bradleyengineeringinc.com
Page
4 / 13
MEMBER REPORT PASSED
04/24/22 Page 27 of 113
Level, Level 2 Joists over Small office break rm
1 piece(s) 11 7/8" TJI® 360 @ 16" OC
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) System : Floor
Member Type : Joist
Member Reaction (lbs) 1663 @ 10' 2 1/2" 1865 (3.50") Passed (89%) 1.00 1.0 D + 1.0 L (All Spans)
Building Use : Residential
Shear (lbs) 1638 @ 10' 1 1/2" 1705 Passed (96%) 1.00 1.0 D + 1.0 L (All Spans)
Building Code : IBC
2015
Moment (Ft-lbs) 5515 @ 6' 6" 6180 Passed (89%) 1.00 1.0 D + 1.0 L (All Spans) Design Methodology
: ASD
Live Load Defl. (in) 0.132 @ 6' 6" 0.246 Passed (L/892) -- 1.0 D + 1.0 L (All Spans)
Total Load Defl. (in) 0.252 @ 6' 6" 0.492 Passed (L/468) -- 1.0 D + 1.0 L (All Spans)
TJ-Proâ„¢ Rating 67 40 Passed -- --
• Deflection criteria: LL (L/480) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge™ Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-Pro™ Rating include: 5/8" Gypsum ceiling, bridging or blocking at max. 8' o.c., Pour Flooring Overlay.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Roof Live Snow Total Accessories
1 - Stud wall - DF 5.50" 4.25" 2.18" 541 652 116 146 1455 1 1/4" Rim Board
2 - Stud wall - DF 3.50" 3.50" 2.67" 779 885 191 241 2096 Blocking, Web Stiffeners
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu) 3' 9" o/c
Bottom Edge (Lu) 10' 4" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
•Maximum allowable bracing intervals based on applied load.
Dead Floor Live Roof Live Snow
Vertical Loads Location Spacing (0.90) (1.00) (non-snow: 1.25) (1.15) Comments
1 - Uniform (PSF) 0 to 10' 5" 16" 24.0 40.0 - - Default Load
2 - Point (PLF) 6' 6" 16" 560.0 736.0 - -
3 - Point (PLF) 6' 6" 16" 180.0 - 230.0 290.0
• Web stiffeners required at location 6' 6" due to loads.
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims
any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer
of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software.
Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation
reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator Job Notes 4/24/2022 9:38:36 PM
UTC
Luke Schweigert
Bradley Engineering Inc. ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
(360) 510-9514 File Name: Paisley
Lofts
luke@bradleyengineeringinc.com
Page
5 / 13
MEMBER REPORT PASSED
04/24/22 Page 28 of 113
Level, Level 2 Joists over Small office at cantilever
1 piece(s) 11 7/8" TJI® 360 @ 16" OC
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) System : Floor
Member Type : Joist
Member Reaction (lbs) 485 @ 8" 1080 (1.75") Passed (45%) 1.00 1.0 D + 1.0 L (Alt Spans)
Building Use : Residential
Shear (lbs) 2221 @ 16' 4 1/2" 2700 Passed (82%) 1.00 1.0 D + 1.0 L (All Spans)
Building Code : IBC
2015
Moment (Ft-lbs) -4356 @ 16' 1 3/4" 6180 Passed (70%) 1.00 1.0 D + 1.0 L (All Spans) Design Methodology
: ASD
Live Load Defl. (in) 0.167 @ 8' 4 7/8" 0.387 Passed (L/999+) -- 1.0 D + 1.0 L (Alt Spans)
Total Load Defl. (in) 0.177 @ 18' 4 1/2" 0.223 Passed (2L/302) -- 1.0 D + 0.75 L + 0.75 S (Alt Spans)
TJ-Proâ„¢ Rating 53 40 Passed -- --
• Deflection criteria: LL (L/480) and TL (L/240).
• Overhang deflection criteria: LL (2L/480) and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge™ Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-Pro™ Rating include: 5/8" Gypsum ceiling, bridging or blocking at max. 8' o.c., Pour Flooring Overlay.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Roof Live Snow Total Accessories
1 - Hanger on steel 1.75" / 542/-
8.00" Hanger¹ 94 448/-70 -30 -38 See note ¹
1.75" ² 138
2 - Stud wall - DF Blocking, Cantilever
5.50" 5.50" 5.25" 1798 1384 264 332 3778
Reinforcement
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• Right end cantilever reinforcement: Apply to both sides of the joist per SPECIFIER'S GUIDE detail E3.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• ¹ See Connector grid below for additional information and/or requirements.
• ² Required Bearing Length / Required Bearing Length with Web Stiffeners
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu) 8' 2" o/c
Bottom Edge (Lu) 4' 4" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
•Maximum allowable bracing intervals based on applied load.
Connector: Simpson Strong-Tie
Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories
1 - Top Mount Hanger HB2.31X H=11.813 4.00" 4-1/8 WELD N/A 10-10dx1.5 Web Stiffeners
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Dead Floor Live Roof Live Snow
Vertical Loads Location Spacing (0.90) (1.00) (non-snow: 1.25) (1.15) Comments
1 - Uniform (PSF) 0 to 18' 4 1/2" 16" 24.0 40.0 - - Default Load
2 - Point (PLF) 18' 2" 16" 420.0 560.0 - -
3 - Point (PLF) 18' 2" 16" 132.0 - 175.0 220.0
4 - Point (PLF) 18' 2" 16" 426.0 - - -
ForteWEB Software Operator Job Notes 4/24/2022 9:38:36 PM
UTC
Luke Schweigert
Bradley Engineering Inc. ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
(360) 510-9514 File Name: Paisley
Lofts
luke@bradleyengineeringinc.com
Page
6 / 13
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims
any other warranties04/24/22 Page 29 of 113
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer
of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software.
Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation
reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator Job Notes 4/24/2022 9:38:36 PM
UTC
Luke Schweigert
Bradley Engineering Inc. ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
(360) 510-9514 File Name: Paisley
Lofts
luke@bradleyengineeringinc.com
Page
7 / 13
MEMBER REPORT PASSED
04/24/22 Page 30 of 113
Level, Level 2 joists over west parking, north cant.
1 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam® LVL @ 16" OC
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) System : Floor
Member Type : Joist
Member Reaction (lbs) 3144 @ 8' 5 1/4" 6016 (5.50") Passed (52%) -- 1.0 D + 1.0 L (All Spans)
Building Use : Residential
Shear (lbs) 2137 @ 9' 7 7/8" 3948 Passed (54%) 1.00 1.0 D + 1.0 L (All Spans)
Building Code : IBC
2015
Moment (Ft-lbs) -4442 @ 8' 5 1/4" 9281 Passed (48%) 1.00 1.0 D + 1.0 L (All Spans) Design Methodology
: ASD
Live Load Defl. (in) 0.050 @ 10' 8" 0.200 Passed (2L/999+) -- 1.0 D + 0.75 L + 0.75 S (Alt Spans)
Total Load Defl. (in) 0.126 @ 10' 8" 0.223 Passed (2L/426) -- 1.0 D + 0.75 L + 0.75 S (Alt Spans)
TJ-Proâ„¢ Rating 71 40 Passed -- --
• Deflection criteria: LL (L/480) and TL (L/240).
• Overhang deflection criteria: LL (2L/0.2") and TL (2L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A 4% increase in the moment capacity has been added to account for repetitive member usage.
• -390 lbs uplift at support located at 8". Strapping or other restraint may be required.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge™ Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-Pro™ Rating include: 5/8" Gypsum ceiling, bridging or blocking at max. 8' o.c., Pour Flooring Overlay.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Roof Live Snow Total Accessories
1 - Hanger on 11 7/8" DF beam 243/-
8.00" Hanger¹ 1.50" -211 243/-180 -62 -78 See note ¹
531
2 - Stud wall - DF 5.50" 5.50" 2.87" 1856 1288 295 371 3810 Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• ¹ See Connector grid below for additional information and/or requirements.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu) 10' o/c
Bottom Edge (Lu) 10' o/c
•Maximum allowable bracing intervals based on applied load.
Connector: Simpson Strong-Tie
Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories
1 - Face Mount Hanger U14 2.00" N/A 14-10dx1.5 6-10dx1.5
• Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Dead Floor Live Roof Live Snow
Vertical Loads Location (Side) Spacing (0.90) (1.00) (non-snow: 1.25) (1.15) Comments
1 - Uniform (PSF) 0 to 10' 8" 16" 24.0 40.0 - - Default Load
2 - Point (PLF) 10' 6" 16" 420.0 560.0 - -
3 - Point (PLF) 10' 6" 16" 132.0 - 175.0 220.0
4 - Point (PLF) 10' 6" 16" 426.0 - - -
ForteWEB Software Operator Job Notes 4/24/2022 9:38:36 PM
UTC
Luke Schweigert
Bradley Engineering Inc. ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
(360) 510-9514 File Name: Paisley
Lofts
luke@bradleyengineeringinc.com
Page
8 / 13
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims
any other warranties04/24/22 Page 31 of 113
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer
of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software.
Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation
reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator Job Notes 4/24/2022 9:38:36 PM
UTC
Luke Schweigert
Bradley Engineering Inc. ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
(360) 510-9514 File Name: Paisley
Lofts
luke@bradleyengineeringinc.com
Page
9 / 13
MEMBER REPORT PASSED
04/24/22 Page 32 of 113
Level, Level 3 Rooftop Deck Joists
1 piece(s) 11 7/8" TJI® 360 @ 16" OC
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) System : Floor
Member Type : Joist
Member Reaction (lbs) 992 @ 17' 10 1/2" 1202 (2.25") Passed (83%) 1.00 1.0 D + 1.0 L (All Spans)
Building Use : Residential
Shear (lbs) 971 @ 5 1/2" 1705 Passed (57%) 1.00 1.0 D + 1.0 L (All Spans)
Building Code : IBC
2015
Moment (Ft-lbs) 4287 @ 9' 1 1/2" 6180 Passed (69%) 1.00 1.0 D + 1.0 L (All Spans) Design Methodology
: ASD
Live Load Defl. (in) 0.395 @ 9' 1 1/2" 0.438 Passed (L/532) -- 1.0 D + 1.0 L (All Spans)
Total Load Defl. (in) 0.553 @ 9' 1 1/2" 0.875 Passed (L/380) -- 1.0 D + 1.0 L (All Spans)
TJ-Proâ„¢ Rating 50 40 Passed -- --
• Deflection criteria: LL (L/480) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge™ Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-Pro™ Rating include: 5/8" Gypsum ceiling.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Stud wall - DF 5.50" 4.25" 1.75" 292 730 1022 1 1/4" Rim Board
2 - Stud wall - DF 3.50" 2.25" 1.75" 287 717 1004 1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu) 4' 5" o/c
Bottom Edge (Lu) 17' 11" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
•Maximum allowable bracing intervals based on applied load.
Dead Floor Live
Vertical Load Location Spacing (0.90) (1.00) Comments
1 - Uniform (PSF) 0 to 18' 1" 16" 24.0 60.0 Default Load
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims
any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer
of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software.
Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation
reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator Job Notes 4/24/2022 9:38:36 PM
UTC
Luke Schweigert
Bradley Engineering Inc. ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
(360) 510-9514 File Name: Paisley
Lofts
luke@bradleyengineeringinc.com
Page
10 / 13
MEMBER REPORT PASSED
04/24/22 Page 33 of 113
Level, Level 3 & 4 Floor Joists
1 piece(s) 11 7/8" TJI® 210 @ 16" OC
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) System : Floor
Member Type : Joist
Member Reaction (lbs) 756 @ 17' 10 1/2" 1134 (2.25") Passed (67%) 1.00 1.0 D + 1.0 L (All Spans)
Building Use : Residential
Shear (lbs) 740 @ 5 1/2" 1655 Passed (45%) 1.00 1.0 D + 1.0 L (All Spans)
Building Code : IBC
2015
Moment (Ft-lbs) 3267 @ 9' 1 1/2" 3795 Passed (86%) 1.00 1.0 D + 1.0 L (All Spans) Design Methodology
: ASD
Live Load Defl. (in) 0.327 @ 9' 1 1/2" 0.438 Passed (L/642) -- 1.0 D + 1.0 L (All Spans)
Total Load Defl. (in) 0.524 @ 9' 1 1/2" 0.875 Passed (L/401) -- 1.0 D + 1.0 L (All Spans)
TJ-Proâ„¢ Rating 46 40 Passed -- --
• Deflection criteria: LL (L/480) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge™ Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-Pro™ Rating include: 5/8" Gypsum ceiling.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Stud wall - DF 5.50" 4.25" 1.75" 292 487 779 1 1/4" Rim Board
2 - Stud wall - DF 3.50" 2.25" 1.75" 287 478 765 1 1/4" Rim Board
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu) 3' 11" o/c
Bottom Edge (Lu) 17' 11" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
•Maximum allowable bracing intervals based on applied load.
Dead Floor Live
Vertical Load Location Spacing (0.90) (1.00) Comments
1 - Uniform (PSF) 0 to 18' 1" 16" 24.0 40.0 Default Load
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims
any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer
of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software.
Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation
reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator Job Notes 4/24/2022 9:38:36 PM
UTC
Luke Schweigert
Bradley Engineering Inc. ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
(360) 510-9514 File Name: Paisley
Lofts
luke@bradleyengineeringinc.com
Page
11 / 13
MEMBER REPORT PASSED
04/24/22 Page 34 of 113
Level, Roof: Joist
1 piece(s) 11 7/8" TJI® 210 @ 24" OC
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) System : Roof
Member Type : Joist
Member Reaction (lbs) 1632 @ 15' 3 1/4" 2467 (3.50") Passed (66%) 1.15 1.0 D + 1.0 S (All Spans)
Building Use : Residential
Shear (lbs) 783 @ 15' 5" 1903 Passed (41%) 1.15 1.0 D + 1.0 S (All Spans)
Building Code : IBC
2015
Moment (Ft-lbs) -2687 @ 15' 3 1/4" 4364 Passed (62%) 1.15 1.0 D + 1.0 S (All Spans) Design Methodology
: ASD
Live Load Defl. (in) 0.232 @ 24' 9 7/8" 0.586 Passed (L/907) -- 1.0 D + 1.0 S (Alt Spans) Member Pitch : 0.25/12
Total Load Defl. (in) 0.352 @ 24' 11 1/8" 0.878 Passed (L/598) -- 1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Roof Live Snow Total Accessories
1 - Stud wall - DF 5.50" 4.25" 1.75" 167 251 313 731 1 1/4" Rim Board
2 - Stud wall - DF 3.50" 3.50" 3.50" 612 816 1020 2448 None
3 - Stud wall - DF 5.50" 5.50" 1.75" 217 304 380 901 Blocking
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu) 5' 2" o/c
Bottom Edge (Lu) 4' 5" o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
•Maximum allowable bracing intervals based on applied load.
Dead Roof Live Snow
Vertical Load Location Spacing (0.90) (non-snow: 1.25) (1.15) Comments
1 - Uniform (PSF) 0 to 33' 2 1/2" 24" 15.0 20.0 25.0 Default Load
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims
any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer
of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software.
Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation
reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator Job Notes 4/24/2022 9:38:36 PM
UTC
Luke Schweigert
Bradley Engineering Inc. ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
(360) 510-9514 File Name: Paisley
Lofts
luke@bradleyengineeringinc.com
Page
12 / 13
MEMBER REPORT PASSED
04/24/22 Page 35 of 113
Level, Roof: Joist with line load
1 piece(s) 11 7/8" TJI® 210 @ 24" OC
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) System : Roof
Member Type : Joist
Member Reaction (lbs) 1853 @ 15' 3 1/4" 2467 (3.50") Passed (75%) 1.15 1.0 D + 1.0 S (All Spans)
Building Use : Residential
Shear (lbs) 951 @ 15' 5" 1903 Passed (50%) 1.15 1.0 D + 1.0 S (All Spans)
Building Code : IBC
2015
Moment (Ft-lbs) 3416 @ 26' 6" 4364 Passed (78%) 1.15 1.0 D + 1.0 S (Alt Spans) Design Methodology
: ASD
Live Load Defl. (in) 0.338 @ 24' 11 3/4" 0.586 Passed (L/623) -- 1.0 D + 1.0 S (Alt Spans) Member Pitch : 0.25/12
Total Load Defl. (in) 0.543 @ 25' 3/4" 0.878 Passed (L/388) -- 1.0 D + 1.0 S (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Roof Live Snow Total Accessories
1 - Stud wall - DF 5.50" 4.25" 1.75" 149 242 302 693 1 1/4" Rim Board
2 - Stud wall - DF 3.50" 3.50" 3.50" 710 914 1143 2767 None
3 - Stud wall - DF 5.50" 5.50" 1.75" 317 404 506 1227 Blocking
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu) 3' 11" o/c
Bottom Edge (Lu) 4' o/c
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
•Maximum allowable bracing intervals based on applied load.
Dead Roof Live Snow
Vertical Loads Location Spacing (0.90) (non-snow: 1.25) (1.15) Comments
1 - Uniform (PSF) 0 to 33' 2 1/2" 24" 15.0 20.0 25.0 Default Load
2 - Point (PLF) 26' 6" 24" 90.0 90.0 113.0
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims
any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer
of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software.
Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation
reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
ForteWEB Software Operator Job Notes 4/24/2022 9:38:36 PM
UTC
Luke Schweigert
Bradley Engineering Inc. ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
(360) 510-9514 File Name: Paisley
Lofts
luke@bradleyengineeringinc.com
Page
13 / 13
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 36 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 21 APR 2022, 3:52PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : R rafters at pop up roof with 8 ft overhang
Wood Beam Design : R rafters at pop up roof with 8 ft overhang
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 2x12, Sawn, Fully Braced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir-Larch Wood Grade : No.2
Fb - Tension 900 psi Fc - Prll 1350 psi Fv 180 psi Ebend- xx 1600ksi Density 31.21pcf
Fb - Compr 900 psi Fc - Perp 625 psi Ft 575 psi Eminbend - xx 580ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0150, Lr = 0.020, S = 0.0250 k/ft, Trib= 1.330 ft
Design Summary .
Max fb/Fb Ratio = 0.580: 1
fb : Actual : 690.04 psi at 9.500 ft inSpan # 2
Fb : Allowable : 1,190.25 psi
Load Comb : +D+S+H
Max fv/FvRatio = 0.193: 1
fv : Actual : 39.97 psi at 9.500 ft inSpan # 2
Fv : Allowable : 207.00 psi
Load Comb : +D+S+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.214in Total Downward 0.366 in
Left Support 0.08 0.10 0.12 Ratio 896 Ratio 524
Right Support 0.38 0.42 0.53
LC: S Only LC: +D+S+H
Transient Upward -0.019in Total Upward -0.033 in
Ratio 5896 Ratio 3448
LC: S Only LC: +D+S+H
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 37 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 22 APR 2022, 8:38AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : R End rafters at pop up roof with 8 ft overhang
Wood Beam Design : R End rafters at pop up roof with 8 ft overhang
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 2-1.75x11.25, Microllam LVL, Fully Braced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : iLevel Truss Joist Wood Grade : MicroLam LVL 2.0 E
Fb - Tension 2600 psi Fc - Prll 2510 psi Fv 285 psi Ebend- xx 2000ksi Density 42.01pcf
Fb - Compr 2600 psi Fc - Perp 750 psi Ft 1555 psi Eminbend - xx 1016.535ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0150, Lr = 0.020, S = 0.0250 k/ft, Trib= 1.0 ft
Point: D = 0.30, Lr = 0.60, S = 0.750 k @ 17.50 ft
Point: D = 0.30, Lr = 0.60, S = 0.750 k @ -2.0 ft
Design Summary .
Max fb/Fb Ratio = 0.525: 1
fb : Actual : 1,633.12 psi at 9.500 ft inSpan # 2
Fb : Allowable : 3,109.60 psi
Load Comb : +D+S+H
Max fv/FvRatio = 0.164: 1
fv : Actual : 53.91 psi at 9.500 ft inSpan # 2
Fv : Allowable : 327.75 psi
Load Comb : +D+S+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.676in Total Downward 0.983 in
Left Support 0.21 0.29 0.37 Ratio 284 Ratio 194
Right Support 0.91 1.30 1.62
LC: S Only LC: +D+S+H
Transient Upward -0.095in Total Upward -0.136 in
Ratio 1205 Ratio 840
LC: S Only LC: +D+S+H
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 38 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 14 APR 2022, 3:38PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : R-1 typical interior bearing wall beam
Wood Beam Design : R-1 typical interior bearing wall beam
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 3.5x11.875, GLB, Fully Unbraced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F-V4
Fb - Tension 2400 psi Fc - Prll 1650 psi Fv 265 psi Ebend- xx 1800ksi Density 31.21pcf
Fb - Compr 1850 psi Fc - Perp 650 psi Ft 1100 psi Eminbend - xx 950ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.020, Lr = 0.020, S = 0.0250 k/ft, Trib= 16.0 ft
Design Summary .
Max fb/Fb Ratio = 0.280: 1
fb : Actual : 747.76 psi at 3.750 ft inSpan # 1
Fb : Allowable : 2,666.08 psi
Load Comb : +D+S+H
Max fv/FvRatio = 0.240: 1
fv : Actual : 73.01 psi at 0.000 ft inSpan # 1
Fv : Allowable : 304.75 psi
Load Comb : +D+S+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.033in Total Downward 0.059 in
Left Support 1.23 1.20 1.50 Ratio 2763 Ratio 1516
Right Support 1.23 1.20 1.50
LC: S Only LC: +D+S+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 39 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 14 APR 2022, 3:40PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : R-2 typical level 4 window hdr window hdr
Wood Beam Design : R-2 typical level 4 window hdr window hdr
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 4x10, Sawn, Fully Unbraced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir-Larch Wood Grade : No.2
Fb - Tension 900 psi Fc - Prll 1350 psi Fv 180 psi Ebend- xx 1600ksi Density 31.21pcf
Fb - Compr 900 psi Fc - Perp 625 psi Ft 575 psi Eminbend - xx 580ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.020, Lr = 0.020, S = 0.0250 k/ft, Trib= 9.0 ft
Design Summary .
Max fb/Fb Ratio = 0.363: 1
fb : Actual : 445.77 psi at 3.000 ft inSpan # 1
Fb : Allowable : 1,227.30 psi
Load Comb : +D+S+H
Max fv/FvRatio = 0.207: 1
fv : Actual : 42.76 psi at 5.240 ft inSpan # 1
Fv : Allowable : 207.00 psi
Load Comb : +D+S+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.018in Total Downward 0.033 in
Left Support 0.56 0.54 0.68 Ratio 4031 Ratio 2201
Right Support 0.56 0.54 0.68
LC: S Only LC: +D+S+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 40 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 12 APR 2022, 3:38PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Central Beam over big office 2
Steel Beam Design : Central Beam over big office 2
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
STEEL Section : W16x45, Fully Braced
Using Load Resistance Factor Design with ASCE 7-16 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 14.0 ft
Unif Load: D = 0.0240, L = 0.060 k/ft, Trib= 14.0 ft
Unif Load: D = 0.0240, L = 0.040 k/ft, 0.0 to 12.50 ft, Trib= 7.50 ft
Unif Load: D = 0.020, Lr = 0.020, S = 0.0250 k/ft, 0.0 to 12.50 ft, Trib= 7.50 ft
Design Summary .
Max fb/Fb Ratio = 0.700: 1
Mu : Applied 215.950 k-ft at 10.320 ft inSpan # 1
Mn * Phi : Allow 308.625 k-ft
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max fv/FvRatio = 0.252: 1
Vu : Applied 41.927 k at 0.000 ft inSpan # 1
Vn * Phi : Allow 166.635 k
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 10.63 17.71 1.33 1.66 Transient Downward 0.452in Total Downward 0.715 in
Right Support 8.91 16.14 0.55 0.68 Ratio 570 360
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 41 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 21 APR 2022, 3:23PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 3, & 4 Typical exterior hdr
Wood Beam Design : Level 3, & 4 Typical exterior hdr
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 4x10, Sawn, Fully Unbraced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir-Larch Wood Grade : No.2
Fb - Tension 900.0 psi Fc - Prll 1,350.0 psi Fv 180.0 psi Ebend- xx 1,600.0ksi Density 31.210pcf
Fb - Compr 900.0 psi Fc - Perp 625.0 psi Ft 575.0 psi Eminbend - xx 580.0ksi
Applied Loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 9.0 ft
Design Summary .
Max fb/Fb Ratio = 0.583: 1
fb : Actual : 623.18 psi at 3.000 ft inSpan # 1
Fb : Allowable : 1,069.18 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.332: 1
fv : Actual : 59.78 psi at 5.240 ft inSpan # 1
Fv : Allowable : 180.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.029in Total Downward 0.046 in
Left Support 0.65 1.08 Ratio 2519 Ratio 1574
Right Support 0.65 1.08
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 42 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 21 APR 2022, 3:21PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 3, & 4 Typical interior bearing header
Wood Beam Design : Level 3, & 4 Typical interior bearing header
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 4x8, Sawn, Fully Unbraced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir-Larch Wood Grade : No.2
Fb - Tension 900 psi Fc - Prll 1350 psi Fv 180 psi Ebend- xx 1600ksi Density 31.21pcf
Fb - Compr 900 psi Fc - Perp 625 psi Ft 575 psi Eminbend - xx 580ksi
Applied Loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 11.0 ft
Design Summary .
Max fb/Fb Ratio = 0.362: 1
fb : Actual : 421.90 psi at 1.750 ft inSpan # 1
Fb : Allowable : 1,164.56 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.267: 1
fv : Actual : 48.07 psi at 2.905 ft inSpan # 1
Fv : Allowable : 180.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.008in Total Downward 0.013 in
Left Support 0.46 0.77 Ratio 5000 Ratio 3125
Right Support 0.46 0.77
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 43 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 1:13PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 3&4 Typical Floor beam at bearing line
Wood Beam Design : Level 3&4 Typical Floor beam at bearing line
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 3.5x11.875, GLB, Fully Unbraced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F-V4
Fb - Tension 2,400.0 psi Fc - Prll 1,650.0 psi Fv 265.0 psi Ebend- xx 1,800.0ksi Density 31.210pcf
Fb - Compr 1,850.0 psi Fc - Perp 650.0 psi Ft 1,100.0 psi Eminbend - xx 950.0ksi
Applied Loads
Unif Load: D = 0.0240 k/ft, Trib= 16.0 ft
Design Summary .
Max fb/Fb Ratio = 0.187: 1
fb : Actual : 393.88 psi at 3.750 ft inSpan # 1
Fb : Allowable : 2,108.78 psi
Load Comb : +D+H
Max fv/FvRatio = 0.161: 1
fv : Actual : 38.46 psi at 0.000 ft inSpan # 1
Fv : Allowable : 238.50 psi
Load Comb : +D+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.000in Total Downward 0.031 in
Left Support 1.44 Ratio 9999 Ratio 2878
Right Support 1.44
LC: LC: +D+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 44 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 14 APR 2022, 5:30PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 3 bearing line beam below roof deck
Wood Beam Design : Level 3 bearing line beam below roof deck
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 3.5x11.875, GLB, Fully Unbraced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F-V4
Fb - Tension 2,400.0 psi Fc - Prll 1,650.0 psi Fv 265.0 psi Ebend- xx 1,800.0ksi Density 31.210pcf
Fb - Compr 1,850.0 psi Fc - Perp 650.0 psi Ft 1,100.0 psi Eminbend - xx 950.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.060 k/ft, Trib= 16.0 ft
Design Summary .
Max fb/Fb Ratio = 0.621: 1
fb : Actual : 1,447.66 psi at 3.830 ft inSpan # 1
Fb : Allowable : 2,332.17 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.527: 1
fv : Actual : 139.64 psi at 0.000 ft inSpan # 1
Fv : Allowable : 265.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.085in Total Downward 0.120 in
Left Support 1.51 3.68 Ratio 1080 Ratio 766
Right Support 1.51 3.68
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 45 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 15 APR 2022, 8:58AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 3, Notch Beam at transition to rooftop deck
Wood Beam Design : Level 3, Notch Beam at transition to rooftop deck
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 5.5x9.5, GLB, Fully Unbraced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F-V4
Fb - Tension 2400 psi Fc - Prll 1650 psi Fv 265 psi Ebend- xx 1800ksi Density 31.21pcf
Fb - Compr 1850 psi Fc - Perp 650 psi Ft 1100 psi Eminbend - xx 950ksi
Applied Loads
Unif Load: D = 0.0240, L = 0.060 k/ft, Trib= 11.0 ft
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 7.50 ft
Unif Load: D = 0.020, Lr = 0.020, S = 0.0250 k/ft, Trib= 7.50 ft
Point: D = 2.50, L = 0.40 k @ 4.0 ft
Design Summary .
Max fb/Fb Ratio = 0.444: 1
fb : Actual : 1,061.76 psi at 3.063 ft inSpan # 1
Fb : Allowable : 2,388.85 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.549: 1
fv : Actual : 145.41 psi at 4.463 ft inSpan # 1
Fv : Allowable : 265.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.025in Total Downward 0.052 in
Left Support 2.15 2.62 0.39 0.49 Ratio 2492 Ratio 1211
Right Support 3.46 2.82 0.39 0.49
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 46 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 15 APR 2022, 8:51AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 3, Unit 216 bearing beam with offset point load
Wood Beam Design : Level 3, Unit 216 bearing beam with offset point load
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 3.5x11.875, GLB, Fully Unbraced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F-V4
Fb - Tension 2400 psi Fc - Prll 1650 psi Fv 265 psi Ebend- xx 1800ksi Density 31.21pcf
Fb - Compr 1850 psi Fc - Perp 650 psi Ft 1100 psi Eminbend - xx 950ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.060 k/ft, Trib= 15.0 ft
Point: D = 5.0, L = 0.80 k @ 0.50 ft
Design Summary .
Max fb/Fb Ratio = 0.652: 1
fb : Actual : 1,521.77 psi at 3.450 ft inSpan # 1
Fb : Allowable : 2,333.84 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.532: 1
fv : Actual : 141.05 psi at 6.525 ft inSpan # 1
Fv : Allowable : 265.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.076in Total Downward 0.123 in
Left Support 6.05 4.12 Ratio 1183 Ratio 728
Right Support 1.72 3.43
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 47 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 15 APR 2022, 8:43AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 3 rim joist between main floor and roof deck
Wood Beam Design : Level 3 rim joist between main floor and roof deck
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 2-1.75x11.87, Microllam LVL, Fully Braced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : iLevel Truss Joist Wood Grade : MicroLam LVL 2.0 E
Fb - Tension 2600 psi Fc - Prll 2510 psi Fv 285 psi Ebend- xx 2000ksi Density 42.01pcf
Fb - Compr 2600 psi Fc - Perp 750 psi Ft 1555 psi Eminbend - xx 1016.535ksi
Applied Loads
Unif Load: D = 0.0120 k/ft, Trib= 24.0 ft
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 1.330 ft
Design Summary .
Max fb/Fb Ratio = 0.629: 1
fb : Actual : 1,634.63 psi at 7.750 ft inSpan # 1
Fb : Allowable : 2,600.00 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.320: 1
fv : Actual : 91.14 psi at 14.518 ft inSpan # 1
Fv : Allowable : 285.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.071in Total Downward 0.499 in
Left Support 2.48 0.41 Ratio 2615 Ratio 372
Right Support 2.48 0.41
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 48 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 1:11PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 3 9 ft second floor window hdr
Wood Beam Design : Level 3 9 ft second floor window hdr
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 3.5x9, GLB, Fully Unbraced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F-V4
Fb - Tension 2,400.0 psi Fc - Prll 1,650.0 psi Fv 265.0 psi Ebend- xx 1,800.0ksi Density 31.210pcf
Fb - Compr 1,850.0 psi Fc - Perp 650.0 psi Ft 1,100.0 psi Eminbend - xx 950.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.060 k/ft, Trib= 8.0 ft
Design Summary .
Max fb/Fb Ratio = 0.743: 1
fb : Actual : 1,745.56 psi at 4.500 ft inSpan # 1
Fb : Allowable : 2,347.94 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.461: 1
fv : Actual : 122.19 psi at 8.280 ft inSpan # 1
Fv : Allowable : 265.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.186in Total Downward 0.263 in
Left Support 0.89 2.16 Ratio 580 Ratio 410
Right Support 0.89 2.16
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 49 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 1:18PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 backspan beam over west parking for north cant.
Wood Beam Design : Level 2 backspan beam over west parking for north cant.
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 5.5x11.875, GLB, Fully Unbraced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F-V4
Fb - Tension 2400 psi Fc - Prll 1650 psi Fv 265 psi Ebend- xx 1800ksi Density 31.21pcf
Fb - Compr 1850 psi Fc - Perp 650 psi Ft 1100 psi Eminbend - xx 950ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 3.50 ft
Design Summary .
Max fb/Fb Ratio = 0.448: 1
fb : Actual : 1,044.55 psi at 9.758 ft inSpan # 1
Fb : Allowable : 2,334.13 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.219: 1
fv : Actual : 58.03 psi at 20.330 ft inSpan # 1
Fv : Allowable : 265.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.352in Total Downward 0.598 in
Left Support 0.95 1.36 Ratio 693 Ratio 407
Right Support 1.46 2.08
LC: L Only LC: +D+L+H
Transient Upward -0.208in Total Upward -0.354 in
Ratio 490 Ratio 288
LC: L Only LC: +D+L+H
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 50 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 3:52PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 beam over bike racks
Steel Beam Design : Level 2 beam over bike racks
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
STEEL Section : W12x40, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-16 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 11.50 ft
Point: D = 10.670, Lr = 3.140, L = 9.420, S = 5.980 k @ 2.0 ft
Point: D = 4.940, Lr = 1.0, L = 4.160, S = 1.30 k @ 2.0 ft
Design Summary .
Max fb/Fb Ratio = 0.541: 1
Mu : Applied 98.180 k-ft at 4.258 ft inSpan # 1
Mn * Phi : Allow 181.638 k-ft
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max fv/FvRatio = 0.464: 1
Vu : Applied 48.818 k at 0.000 ft inSpan # 1
Vn * Phi : Allow 105.315 k
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 16.59 16.05 3.67 6.45 Transient Downward 0.211in Total Downward 0.402 in
Right Support 4.55 5.58 0.47 0.83 Ratio 997 522
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 51 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 12:53PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 Beam over west bath by elevator
Wood Beam Design : Level 2 Beam over west bath by elevator
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 3.5x11.875, GLB, Fully Braced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F-V4
Fb - Tension 2,400.0 psi Fc - Prll 1,650.0 psi Fv 265.0 psi Ebend- xx 1,800.0ksi Density 31.210pcf
Fb - Compr 1,850.0 psi Fc - Perp 650.0 psi Ft 1,100.0 psi Eminbend - xx 950.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 7.50 ft
Unif Load: D = 0.0240, L = 0.0320 k/ft, Trib= 21.0 ft
Unif Load: D = 0.0150, Lr = 0.020, S = 0.0250 k/ft, Trib= 10.50 ft
Design Summary .
Max fb/Fb Ratio = 0.886: 1
fb : Actual : 2,126.95 psi at 4.000 ft inSpan # 1
Fb : Allowable : 2,400.00 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.993: 1
fv : Actual : 263.10 psi at 0.000 ft inSpan # 1
Fv : Allowable : 265.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.102in Total Downward 0.192 in
Left Support 3.40 3.89 0.84 1.05 Ratio 937 Ratio 499
Right Support 3.40 3.89 0.84 1.05
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 52 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 5:51PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 Beam by west stairs
Wood Beam Design : Level 2 Beam by west stairs
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 5.5x11.875, GLB, Fully Braced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F-V4
Fb - Tension 2,400.0 psi Fc - Prll 1,650.0 psi Fv 265.0 psi Ebend- xx 1,800.0ksi Density 31.210pcf
Fb - Compr 1,850.0 psi Fc - Perp 650.0 psi Ft 1,100.0 psi Eminbend - xx 950.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 7.50 ft
Unif Load: D = 0.0240, L = 0.0320 k/ft, Trib= 21.0 ft
Unif Load: D = 0.0150, Lr = 0.020, S = 0.0250 k/ft, Trib= 10.50 ft
Design Summary .
Max fb/Fb Ratio = 0.825: 1
fb : Actual : 1,979.07 psi at 4.830 ft inSpan # 1
Fb : Allowable : 2,400.00 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.765: 1
fv : Actual : 202.74 psi at 0.000 ft inSpan # 1
Fv : Allowable : 265.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.139in Total Downward 0.261 in
Left Support 4.13 4.69 1.01 1.27 Ratio 836 Ratio 444
Right Support 4.13 4.69 1.01 1.27
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 53 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 22 APR 2022, 11:28AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 big office north east hdr
Wood Beam Design : Level 2 big office north east hdr
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 5.5x15, GLB, Fully Braced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F-V4
Fb - Tension 2,400.0 psi Fc - Prll 1,650.0 psi Fv 265.0 psi Ebend- xx 1,800.0ksi Density 31.210pcf
Fb - Compr 1,850.0 psi Fc - Perp 650.0 psi Ft 1,100.0 psi Eminbend - xx 950.0ksi
Applied Loads
Beam self weight calculated and added to loads
Point: D = 2.20, L = 3.120 k @ 4.660 ft
Point: D = 1.80, L = 4.60 k @ 4.660 ft
Design Summary .
Max fb/Fb Ratio = 0.815: 1
fb : Actual : 1,956.16 psi at 4.680 ft inSpan # 1
Fb : Allowable : 2,400.00 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.498: 1
fv : Actual : 131.89 psi at 0.000 ft inSpan # 1
Fv : Allowable : 265.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.162in Total Downward 0.249 in
Left Support 2.55 4.72 Ratio 887 Ratio 577
Right Support 1.66 3.00
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 54 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 5:40PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 header big office south east hdr
Wood Beam Design : Level 2 header big office south east hdr
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 5.5x9, GLB, Fully Unbraced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F-V4
Fb - Tension 2,400.0 psi Fc - Prll 1,650.0 psi Fv 265.0 psi Ebend- xx 1,800.0ksi Density 31.210pcf
Fb - Compr 1,850.0 psi Fc - Perp 650.0 psi Ft 1,100.0 psi Eminbend - xx 950.0ksi
Applied Loads
Beam self weight calculated and added to loads
Point: D = 5.0, L = 9.940 k @ 0.50 ft
Design Summary .
Max fb/Fb Ratio = 0.488: 1
fb : Actual : 1,160.13 psi at 0.520 ft inSpan # 1
Fb : Allowable : 2,376.63 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.078: 1
fv : Actual : 20.58 psi at 11.280 ft inSpan # 1
Fv : Allowable : 265.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.133in Total Downward 0.208 in
Left Support 4.86 9.53 Ratio 1085 Ratio 693
Right Support 0.27 0.41
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 55 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 22 APR 2022, 11:07AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 header big office main entry header
Steel Beam Design : Level 2 header big office main entry
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
STEEL Section : W14x26, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-16 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0ksi
Applied Loads
Beam self weight calculated and added to loads
Point: D = 7.60, L = 15.0 k @ 3.0 ft
Design Summary .
Max fb/Fb Ratio = 0.677: 1
Mu : Applied 74.941 k-ft at 3.000 ft inSpan # 1
Mn * Phi : Allow 110.759 k-ft
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.235: 1
Vu : Applied 25.027 k at 0.000 ft inSpan # 1
Vn * Phi : Allow 106.335 k
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 5.86 11.25 Transient Downward 0.092in Total Downward 0.141 in
Right Support 2.06 3.75 Ratio 1559 1022
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 56 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 22 APR 2022, 10:35AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 typical big office window hdr
Wood Beam Design : Level 2 typical big office window hdr
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 3.5x9, GLB, Fully Unbraced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F-V4
Fb - Tension 2,400.0 psi Fc - Prll 1,650.0 psi Fv 265.0 psi Ebend- xx 1,800.0ksi Density 31.210pcf
Fb - Compr 1,850.0 psi Fc - Perp 650.0 psi Ft 1,100.0 psi Eminbend - xx 950.0ksi
Applied Loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 8.0 ft
Design Summary .
Max fb/Fb Ratio = 0.561: 1
fb : Actual : 1,316.57 psi at 4.500 ft inSpan # 1
Fb : Allowable : 2,347.94 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.348: 1
fv : Actual : 92.16 psi at 8.280 ft inSpan # 1
Fv : Allowable : 265.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.124in Total Downward 0.199 in
Left Support 0.86 1.44 Ratio 870 Ratio 543
Right Support 0.86 1.44
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 57 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 5:17PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 Central Beam over big office
Steel Beam Design : Level 2 Central Beam over big office
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
STEEL Section : W16x50, Fully Braced
Using Load Resistance Factor Design with ASCE 7-16 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 14.0 ft
Unif Load: D = 0.0240, L = 0.060 k/ft, Trib= 14.0 ft
Design Summary .
Max fb/Fb Ratio = 0.512: 1
Mu : Applied 176.664 k-ft at 10.665 ft inSpan # 1
Mn * Phi : Allow 345.000 k-ft
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.178: 1
Vu : Applied 33.130 k at 0.000 ft inSpan # 1
Vn * Phi : Allow 185.820 k
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 7.70 14.93 Transient Downward 0.343in Total Downward 0.520 in
Right Support 7.70 14.93 Ratio 746 492
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 58 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 5:52PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 Side Beam over big office
Steel Beam Design : Level 2 Side Beam over big office
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
STEEL Section : W16x50, Fully Braced
Using Load Resistance Factor Design with ASCE 7-16 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 15.0 ft
Unif Load: D = 0.0240, L = 0.060 k/ft, Trib= 15.0 ft
Design Summary .
Max fb/Fb Ratio = 0.531: 1
Mu : Applied 183.236 k-ft at 10.500 ft inSpan # 1
Mn * Phi : Allow 345.000 k-ft
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.188: 1
Vu : Applied 34.902 k at 21.000 ft inSpan # 1
Vn * Phi : Allow 185.820 k
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 8.09 15.75 Transient Downward 0.345in Total Downward 0.523 in
Right Support 8.09 15.75 Ratio 729 482
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 59 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 11:44AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 north entry between office space 103 and 102
Wood Beam Design : Level 2 north entry between office space 103 and 102
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 5.5x12, GLB, Fully Braced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F-V4
Fb - Tension 2,400.0 psi Fc - Prll 1,650.0 psi Fv 265.0 psi Ebend- xx 1,800.0ksi Density 31.210pcf
Fb - Compr 1,850.0 psi Fc - Perp 650.0 psi Ft 1,100.0 psi Eminbend - xx 950.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 10.0 ft
Unif Load: D = 0.0240, L = 0.0320 k/ft, Trib= 18.0 ft
Unif Load: D = 0.0150, Lr = 0.020, S = 0.0250 k/ft, Trib= 9.0 ft
Point: D = 5.80, Lr = 1.120, L = 6.070, S = 1.40 k @ 2.0 ft
Design Summary .
Max fb/Fb Ratio = 0.983: 1
fb : Actual : 2,358.09 psi at 2.007 ft inSpan # 1
Fb : Allowable : 2,400.00 psi
Load Comb : +D+L+H
Max fv/FvRatio = 1.116: 1
fv : Actual : 295.63 psi at 0.000 ft inSpan # 1
Fv : Allowable : 265.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.078in Total Downward 0.148 in
Left Support 7.02 7.75 1.43 1.79 Ratio 1078 Ratio 567
Right Support 4.53 5.15 0.95 1.19
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 60 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 11:35AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 office/lounge 103 window hdr
Wood Beam Design : Level 2 office/lounge 103 window hdr
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 5.5x13.5, GLB, Fully Braced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F-V4
Fb - Tension 2400 psi Fc - Prll 1650 psi Fv 265 psi Ebend- xx 1800ksi Density 31.21pcf
Fb - Compr 1850 psi Fc - Perp 650 psi Ft 1100 psi Eminbend - xx 950ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 10.0 ft
Unif Load: D = 0.0240, L = 0.0320 k/ft, Trib= 18.0 ft
Unif Load: D = 0.0150, Lr = 0.020, S = 0.0250 k/ft, Trib= 9.0 ft
Point: D = 5.80, Lr = 1.120, L = 6.070, S = 1.40 k @ 2.0 ft
Design Summary .
Max fb/Fb Ratio = 0.958: 1
fb : Actual : 2,299.94 psi at 3.030 ft inSpan # 1
Fb : Allowable : 2,400.00 psi
Load Comb : +D+L+H
Max fv/FvRatio = 1.169: 1
fv : Actual : 309.72 psi at 0.000 ft inSpan # 1
Fv : Allowable : 265.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.121in Total Downward 0.228 in
Left Support 8.22 9.11 1.68 2.10 Ratio 893 Ratio 472
Right Support 4.99 5.74 1.06 1.32
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 61 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 22 APR 2022, 11:29AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 small office north window hdr
Steel Beam Design : Level 2 small office north window hdr
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
STEEL Section : W14x26, Fully Unbraced
Using Load Resistance Factor Design with ASCE 7-16 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 10.0 ft
Unif Load: D = 0.0240, L = 0.0320 k/ft, Trib= 18.0 ft
Unif Load: D = 0.0150, Lr = 0.020, S = 0.0250 k/ft, Trib= 9.0 ft
Point: D = 5.80, Lr = 1.120, L = 6.070, S = 1.40 k @ 2.0 ft
Design Summary .
Max fb/Fb Ratio = 0.737: 1
Mu : Applied 67.066 k-ft at 4.920 ft inSpan # 1
Mn * Phi : Allow 90.969 k-ft
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max fv/FvRatio = 0.287: 1
Vu : Applied 30.519 k at 0.000 ft inSpan # 1
Vn * Phi : Allow 106.335 k
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 9.83 10.91 2.01 2.52 Transient Downward 0.090in Total Downward 0.170 in
Right Support 5.96 6.87 1.27 1.58 Ratio 1593 846
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 62 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 14 APR 2022, 10:20AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 beam supporting office beams
Steel Beam Design : Level 2 beam supporting office beams
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
STEEL Section : W12x53, Defined Brace Locations, 1st at 4.750 ft, 2nd at ft, 3rd at ft
Using Load Resistance Factor Design with ASCE 7-16 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 1.330 ft
Point: D = 20.20, Lr = 4.60, L = 22.670, S = 5.750 k @ 5.0 ft
Design Summary .
Max fb/Fb Ratio = 0.843: 1
Mu : Applied 246.310 k-ft at 4.988 ft inSpan # 1
Mn * Phi : Allow 292.125 k-ft
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max fv/FvRatio = 0.398: 1
Vu : Applied 49.844 k at 0.000 ft inSpan # 1
Vn * Phi : Allow 125.235 k
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 16.14 17.69 3.48 4.35 Transient Downward 0.410in Total Downward 0.788 in
Right Support 5.80 6.07 1.12 1.40 Ratio 599 312
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 63 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 1:08PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 Beam over small office
Steel Beam Design : Level 2 Beam over small office
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
STEEL Section : W12x53, Fully Braced
Using Load Resistance Factor Design with ASCE 7-16 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0ksi
Applied Loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 11.50 ft
Unif Load: D = 0.0240, L = 0.0320 k/ft, 0.0 to 7.250 ft, Trib= 26.0 ft
Unif Load: D = 0.0240, Lr = 0.020, S = 0.0250 k/ft, 0.0 to 7.250 ft, Trib= 13.0 ft
Point: D = 2.340, L = 3.90 k @ 7.250 ft
Point: D = 0.7320, Lr = 0.9750, S = 1.220 k @ 7.250 ft
Design Summary .
Max fb/Fb Ratio = 0.359: 1
Mu : Applied 104.983 k-ft at 7.250 ft inSpan # 1
Mn * Phi : Allow 292.125 k-ft
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max fv/FvRatio = 0.222: 1
Vu : Applied 27.835 k at 0.000 ft inSpan # 1
Vn * Phi : Allow 125.235 k
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 8.80 10.04 1.93 2.42 Transient Downward 0.118in Total Downward 0.215 in
Right Support 5.19 6.79 0.93 1.16 Ratio 1524 835
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 64 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 1:08PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 Beam 2 over small office
Steel Beam Design : Level 2 Beam 2 over small office
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
STEEL Section : W12x53, Fully Braced
Using Load Resistance Factor Design with ASCE 7-16 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 10.0 ft
Unif Load: D = 0.0240, L = 0.0320 k/ft, Trib= 26.0 ft
Unif Load: D = 0.0150, Lr = 0.020, S = 0.0250 k/ft, Trib= 13.0 ft
Design Summary .
Max fb/Fb Ratio = 0.624: 1
Mu : Applied 182.184 k-ft at 10.250 ft inSpan # 1
Mn * Phi : Allow 292.125 k-ft
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max fv/FvRatio = 0.284: 1
Vu : Applied 35.548 k at 0.000 ft inSpan # 1
Vn * Phi : Allow 125.235 k
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 11.40 12.63 2.67 3.33 Transient Downward 0.399in Total Downward 0.760 in
Right Support 11.40 12.63 2.67 3.33 Ratio 616 323
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 65 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 1:07PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 beam over south parking below wall line
Steel Beam Design : Level 2 beam over south parking below wall line
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
STEEL Section : W18x65, Fully Braced
Using Allowable Strength Design with ASCE 7-16 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.030 k/ft, Trib= 12.0 ft
Unif Load: D = 0.0240, L = 0.030 k/ft, Trib= 16.0 ft
Unif Load: D = 0.0240, L = 0.030 k/ft, Trib= 16.0 ft
Unif Load: D = 0.020, Lr = 0.020, S = 0.0250 k/ft, Trib= 16.0 ft
Design Summary .
Max fb/Fb Ratio = 0.676: 1
Mu : Applied 224.418 k-ft at 12.750 ft inSpan # 1
Mn / Omega : Allow 331.836 k-ft
Load Comb : +D+L+H
Max fv/FvRatio = 0.213: 1
Vu : Applied 35.203 k at 0.000 ft inSpan # 1
Vn / Omega : Allow 165.60 k
Load Comb : +D+L+H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 18.37 16.83 4.08 5.10 Transient Downward 0.407in Total Downward 0.851 in
Right Support 18.37 16.83 4.08 5.10 Ratio 752 359
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 66 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 1:05PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 edge beam over south parking below wall line
Steel Beam Design : Level 2 Edge beam over south parking below wall line
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
STEEL Section : W18x65, Fully Braced
Using Load Resistance Factor Design with ASCE 7-16 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.030 k/ft, Trib= 9.750 ft
Unif Load: D = 0.0240, L = 0.030 k/ft, Trib= 9.750 ft
Unif Load: D = 0.0240, L = 0.030 k/ft, Trib= 9.750 ft
Unif Load: D = 0.020, Lr = 0.020, S = 0.0250 k/ft, Trib= 9.750 ft
Design Summary .
Max fb/Fb Ratio = 0.437: 1
Mu : Applied 217.856 k-ft at 12.750 ft inSpan # 1
Mn * Phi : Allow 498.750 k-ft
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max fv/FvRatio = 0.138: 1
Vu : Applied 34.174 k at 0.000 ft inSpan # 1
Vn * Phi : Allow 248.40 k
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 12.27 11.19 2.49 3.11 Transient Downward 0.270in Total Downward 0.567 in
Right Support 12.27 11.19 2.49 3.11 Ratio 1131 539
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 67 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 11:57AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 interor bearing wall header smal offive 102
Wood Beam Design : Level 2 interor bearing wall header smal offive 102
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 4x10, Sawn, Fully Braced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir-Larch Wood Grade : No.2
Fb - Tension 900.0 psi Fc - Prll 1,350.0 psi Fv 180.0 psi Ebend- xx 1,600.0ksi Density 31.210pcf
Fb - Compr 900.0 psi Fc - Perp 625.0 psi Ft 575.0 psi Eminbend - xx 580.0ksi
Applied Loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 7.50 ft
Unif Load: D = 0.0240, L = 0.0320 k/ft, Trib= 23.0 ft
Unif Load: D = 0.0150, Lr = 0.020, S = 0.0250 k/ft, Trib= 4.50 ft
Design Summary .
Max fb/Fb Ratio = 0.460: 1
fb : Actual : 496.46 psi at 1.500 ft inSpan # 1
Fb : Allowable : 1,080.00 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.345: 1
fv : Actual : 62.08 psi at 2.230 ft inSpan # 1
Fv : Allowable : 180.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.005in Total Downward 0.009 in
Left Support 1.20 1.55 0.14 0.17 Ratio 7004 Ratio 3953
Right Support 1.20 1.55 0.14 0.17
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 68 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 11:51AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 South wall window header near elevator
Wood Beam Design : Level 2 South wall window header near elevator
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 6x10, Sawn, Fully Braced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : Douglas Fir-Larch Wood Grade : No.2
Fb - Tension 900 psi Fc - Prll 1350 psi Fv 180 psi Ebend- xx 1600ksi Density 31.21pcf
Fb - Compr 900 psi Fc - Perp 625 psi Ft 575 psi Eminbend - xx 580ksi
Applied Loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 7.50 ft
Design Summary .
Max fb/Fb Ratio = 0.783: 1
fb : Actual : 704.95 psi at 4.500 ft inSpan # 1
Fb : Allowable : 900.00 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.285: 1
fv : Actual : 51.26 psi at 0.000 ft inSpan # 1
Fv : Allowable : 180.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.071in Total Downward 0.113 in
Left Support 0.81 1.35 Ratio 1525 Ratio 953
Right Support 0.81 1.35
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 69 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 14 APR 2022, 2:44PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 header Break Room
Wood Beam Design : Level 2 Header Break Room
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 5.5x12, GLB, Fully Braced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F-V4
Fb - Tension 2400 psi Fc - Prll 1650 psi Fv 265 psi Ebend- xx 1800ksi Density 31.21pcf
Fb - Compr 1850 psi Fc - Perp 650 psi Ft 1100 psi Eminbend - xx 950ksi
Applied Loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 9.0 ft
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 9.0 ft
Unif Load: D = 0.0150, Lr = 0.020, S = 0.0250 k/ft, Trib= 4.50 ft
Design Summary .
Max fb/Fb Ratio = 0.831: 1
fb : Actual : 1,995.55 psi at 6.000 ft inSpan # 1
Fb : Allowable : 2,400.00 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.527: 1
fv : Actual : 139.69 psi at 11.040 ft inSpan # 1
Fv : Allowable : 265.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.237in Total Downward 0.401 in
Left Support 3.00 4.32 0.54 0.68 Ratio 607 Ratio 358
Right Support 3.00 4.32 0.54 0.68
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 70 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 1:03PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 beam under bearing line over west parking
Steel Beam Design : Level 2 beam under bearing line over west parking
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
STEEL Section : W12x53, Fully Braced
Using Load Resistance Factor Design with ASCE 7-16 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0ksi
Applied Loads
Unif Load: D = 0.0240, L = 0.030 k/ft, Trib= 16.0 ft
Unif Load: D = 0.0240, L = 0.030 k/ft, Trib= 16.0 ft
Unif Load: D = 0.020, Lr = 0.020, S = 0.0250 k/ft, Trib= 16.0 ft
Design Summary .
Max fb/Fb Ratio = 0.501: 1
Mu : Applied 146.338 k-ft at 9.840 ft inSpan # 1
Mn * Phi : Allow 292.125 k-ft
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max fv/FvRatio = 0.260: 1
Vu : Applied 32.516 k at 20.500 ft inSpan # 1
Vn * Phi : Allow 125.235 k
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 10.67 9.42 3.14 3.92 Transient Downward 0.280in Total Downward 0.615 in
Right Support 16.26 14.34 4.78 5.98 Ratio 878 400
LC: L Only LC: +D+0.750L+0.750S+H
Transient Upward -0.165in Total Upward -0.361 in
Ratio 618 Ratio 282
LC: L Only LC: +D+0.750L+0.750S+H
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 71 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 14 APR 2022, 8:42AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 main beam 2 over west parking
Steel Beam Design : Level 2 Main Beam 2 over West Parking
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
STEEL Section : W18x86, Fully Braced
Using Load Resistance Factor Design with ASCE 7-16 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 15.50 ft
Unif Load: D = 0.0120 k/ft, Trib= 35.50 ft
Point: D = 12.20, Lr = 3.650, L = 10.80, S = 4.50 k @ 3.750 ft
Point: D = 12.20, Lr = 3.650, L = 10.80, S = 4.50 k @ 12.750 ft
Design Summary .
Max fb/Fb Ratio = 0.725: 1
Mu : Applied 505.997 k-ft at 12.787 ft inSpan # 1
Mn * Phi : Allow 697.500 k-ft
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max fv/FvRatio = 0.290: 1
Vu : Applied 76.943 k at 0.000 ft inSpan # 1
Vn * Phi : Allow 264.960 k
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 29.59 23.92 5.15 6.35 Transient Downward 0.462in Total Downward 1.041 in
Right Support 19.57 15.04 2.15 2.65 Ratio 727 322
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 72 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 14 APR 2022, 9:02AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 beam over steel beam at double cant. west parking
Wood Beam Design : Level 2 beam over steel beam at double cant. west parking
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 5.25x11.875, Parallam PSL, Fully Unbraced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : iLevel Truss Joist Wood Grade : MicroLam LVL 2.0 E
Fb - Tension 2600 psi Fc - Prll 2510 psi Fv 285 psi Ebend- xx 2000ksi Density 42.01pcf
Fb - Compr 2600 psi Fc - Perp 750 psi Ft 1555 psi Eminbend - xx 1016.535ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 1.30 ft
Point: D = 5.660, Lr = 1.80, L = 5.20, S = 2.250 k @ 11.750 ft
Design Summary .
Max fb/Fb Ratio = 0.726: 1
fb : Actual : 1,863.32 psi at 10.000 ft inSpan # 1
Fb : Allowable : 2,565.99 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.923: 1
fv : Actual : 263.15 psi at 10.000 ft inSpan # 1
Fv : Allowable : 285.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.070in Total Downward 0.152 in
Left Support -0.75 -0.66 -0.31 -0.39 Ratio 602 Ratio 274
Right Support 6.99 6.47 2.11 2.64
LC: L Only LC: +D+0.750L+0.750S+H
Transient Upward -0.062in Total Upward -0.138 in
Ratio 1932 Ratio 871
LC: L Only LC: +D+0.750L+0.750S+H
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 73 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 14 APR 2022, 9:16AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 Floor Beam edge cant. over west parking
Wood Beam Design : Level 2 Floor Beam edge cant. over west parking
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 3.5x11.875, Parallam PSL, Fully Braced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : iLevel Truss Joist Wood Grade : MicroLam LVL 2.0 E
Fb - Tension 2600 psi Fc - Prll 2510 psi Fv 285 psi Ebend- xx 2000ksi Density 42.01pcf
Fb - Compr 2600 psi Fc - Perp 750 psi Ft 1555 psi Eminbend - xx 1016.535ksi
Applied Loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 17.50 ft
Unif Load: D = 0.0150, Lr = 0.020, S = 0.0250 k/ft, Trib= 8.750 ft
Design Summary .
Max fb/Fb Ratio = 0.658: 1
fb : Actual : 1,711.15 psi at 10.000 ft inSpan # 1
Fb : Allowable : 2,600.00 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.941: 1
fv : Actual : 268.12 psi at 10.000 ft inSpan # 1
Fv : Allowable : 285.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.091in Total Downward 0.162 in
Left Support 2.24 2.84 0.71 0.89 Ratio 1323 Ratio 740
Right Support 5.66 7.19 1.80 2.25
LC: L Only LC: +D+L+H
Transient Upward -0.009in Total Upward -0.017 in
Ratio 9999 Ratio 6278
LC: L Only LC: +D+L+H
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 74 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 1:04PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 main beam over west parking
Steel Beam Design : Level 2 Main Beam over West Parking
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
STEEL Section : W18x86, Fully Braced
Using Load Resistance Factor Design with ASCE 7-16 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 15.50 ft
Unif Load: D = 0.0120 k/ft, Trib= 35.50 ft
Point: D = 16.260, Lr = 4.870, L = 14.340, S = 5.980 k @ 10.50 ft
Design Summary .
Max fb/Fb Ratio = 0.697: 1
Mu : Applied 486.378 k-ft at 10.547 ft inSpan # 1
Mn * Phi : Allow 697.500 k-ft
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max fv/FvRatio = 0.216: 1
Vu : Applied 57.143 k at 0.000 ft inSpan # 1
Vn * Phi : Allow 264.960 k
Load Comb : +1.20D+1.60L+0.50S+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 22.54 17.64 3.04 3.74 Transient Downward 0.430in Total Downward 0.974 in
Right Support 18.47 14.06 1.83 2.24 Ratio 781 344
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 75 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 22 APR 2022, 11:04AM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 Header between vestibule and big office
Steel Beam Design : Level 2 Header between vestibule and big office
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
STEEL Section : W14x26, Fully Braced
Using Load Resistance Factor Design with ASCE 7-16 Load Combinations, Major Axis Bending Fy = 50.0 ksi E = 29,000.0ksi
Applied Loads
Point: D = 7.70, L = 15.0 k @ 3.50 ft
Point: D = 4.40, L = 5.20 k @ 3.50 ft
Design Summary .
Max fb/Fb Ratio = 0.652: 1
Mu : Applied 98.364 k-ft at 3.500 ft inSpan # 1
Mn * Phi : Allow 150.750 k-ft
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max fv/FvRatio = 0.264: 1
Vu : Applied 28.104 k at 0.000 ft inSpan # 1
Vn * Phi : Allow 106.335 k
Load Comb : +1.20D+0.50Lr+1.60L+1.60H
Max Reactions (k) D L Lr S W E H Max Deflections
Left Support 7.26 12.12 Transient Downward 0.065in Total Downward 0.105 in
Right Support 4.84 8.08 Ratio 1606 1004
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22You can change this area Engineer: Page 76 of 113
using the "Settings" menu item Project ID:
and then using the "Printing & Project Descr:
Title Block" selection.
Title Block Line 6 Printed: 15 APR 2022, 1:35PM
File: Paisley Loft Calcs.ec6
Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
Description : Level 2 Beam over Vestibule
Wood Beam Design : Level 2 Beam over Vestibule
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size : 5.5x11.875, GLB, Fully Unbraced
Using Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Species : DF/DF Wood Grade : 24F-V4
Fb - Tension 2,400.0 psi Fc - Prll 1,650.0 psi Fv 265.0 psi Ebend- xx 1,800.0ksi Density 31.210pcf
Fb - Compr 1,850.0 psi Fc - Perp 650.0 psi Ft 1,100.0 psi Eminbend - xx 950.0ksi
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 5.0 ft
Unif Load: D = 0.0240, L = 0.040 k/ft, Trib= 22.0 ft
Unif Load: D = 0.020, Lr = 0.020, S = 0.0250 k/ft, Trib= 11.0 ft
Design Summary .
Max fb/Fb Ratio = 0.912: 1
fb : Actual : 2,164.49 psi at 4.875 ft inSpan # 1
Fb : Allowable : 2,373.07 psi
Load Comb : +D+L+H
Max fv/FvRatio = 0.663: 1
fv : Actual : 175.75 psi at 8.775 ft inSpan # 1
Fv : Allowable : 265.00 psi
Load Comb : +D+L+H Max Deflections
Max Reactions (k) D L Lr S W E H Transient Downward 0.160in Total Downward 0.290 in
Left Support 4.30 5.27 1.07 1.34 Ratio 732 Ratio 402
Right Support 4.30 5.27 1.07 1.34
LC: L Only LC: +D+L+H
Transient Upward 0.000in Total Upward 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
Title Block Line 1 Project Title:
04/24/22 Page 77 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 6:08PM
File: Paisley Loft Calcs.ec6
Wood Column Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: P Level 1 trimmer stud small office north window hdr
.
Code References
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Analysis Method : Allowable Stress Design Wood Section Name 4-2x6
End Fixities Top & Bottom Pinned Wood Grading/Manuf. Graded Lumber
Overall Column Height 10 ft Wood Member Type Sawn
( Used for non-slender calculations )
Exact Width 6.0 in Allow Stress Modification Factors
Wood Species Douglas Fir-Larch
Exact Depth 5.50 in Cf or Cv for Bending 1.30
Wood Grade No.2
Area 33.0 in^2 Cf or Cv for Compression 1.10
Fb + 900.0psi Fv 180.0 psi Ix 83.188 in^4 Cf or Cv for Tension 1.30
Fb - 900.0psi Ft 575.0 psi Iy 99.0 in^4 Cm : Wet Use Factor 1.0
Fc - Prll 1,350.0psi Density 31.210 pcf
Ct : Temperature Factor 1.0
Fc - Perp 625.0psi
Cfu : Flat Use Factor 1.0
E : Modulus of Elasticity . . . x-x Bending y-y Bending Axial
Kf : Built-up columns 1.0 NDS 15.3.2
Basic 1,600.0 1,600.0 1,600.0ksi Use Cr : Repetitive ? No
Minimum 580.0 580.0 Brace condition for deflection (buckling) along columns :
X-X (width) axis : Fully braced against buckling ABOUT Y-Y Axis
Y-Y (depth) axis : Unbraced Length for buckling ABOUT X-X Axis = 10 ft, K = 1.0
.
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Column self weight included : 71.523 lbs * Dead Load Factor
AXIAL LOADS . . .
Axial Load at 10.0 ft, D = 9.930, Lr = 2.010, L = 10.910, S = 2.520 k
.
DESIGN SUMMARY
Bending & Shear Check Results
PASS Max. Axial+Bending Stress Ratio = 0.7839 : 1 Maximum SERVICE Lateral Load Reactions . .
Load Combination +D+L Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k
Governing NDS Forumla Comp Only, fc/Fc' Top along X-X 0.0 k Bottom along X-X 0.0 k
Location of max.above base 0.0 ft
Maximum SERVICE Load Lateral Deflections . . .
At maximum location values are . . .
Along Y-Y 0.0 in at 0.0 ft above base
Applied Axial 20.912k
for load combination : n/a
Applied Mx 0.0 k-ft
Along X-X 0.0 in at 0.0 ft above base
Applied My 0.0 k-ft
Fc : Allowable 808.37 psi for load combination : n/a
Other Factors used to calculate allowable stresses . . .
PASS Maximum Shear Stress Ratio = 0.0 : 1 Bending Compression Tension
Load Combination +0.60D
Location of max.above base 10.0 ft
Applied Design Shear 0.0 psi
Allowable Shear 288.0 psi
.
Load Combination Results
Maximum Axial + Bending Stress Ratios Maximum Shear Ratios
Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location
D Only 0.900 0.585 0.3878 PASS 0.0ft 0.0 PASS 10.0 ft
+D+L 1.000 0.544 0.7839 PASS 0.0ft 0.0 PASS 10.0 ft
+D+Lr 1.250 0.461 0.4255 PASS 0.0ft 0.0 PASS 10.0 ft
+D+S 1.150 0.491 0.4521 PASS 0.0ft 0.0 PASS 10.0 ft
+D+0.750Lr+0.750L 1.250 0.461 0.6976 PASS 0.0ft 0.0 PASS 10.0 ft
+D+0.750L+0.750S 1.150 0.491 0.7248 PASS 0.0ft 0.0 PASS 10.0 ft
+0.60D 1.600 0.376 0.2035 PASS 0.0ft 0.0 PASS 10.0 ft
.
Title Block Line 1 Project Title:
04/24/22 Page 78 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 6:08PM
File: Paisley Loft Calcs.ec6
Wood Column Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: P Level 1 trimmer stud small office north window hdr
Maximum Reactions Note: Only non-zero reactions are listed.
X-X Axis Reaction k Y-Y Axis Reaction Axial Reaction My - End Moments k-ft Mx - End Moments
Load Combination @ Base @ Top @ Base @ Top @ Base @ Base @ Top @ Base @ Top
D Only 10.002
+D+L 20.912
+D+Lr 12.012
+D+S 12.522
+D+0.750Lr+0.750L 19.692
+D+0.750L+0.750S 20.074
+0.60D 6.001
Lr Only 2.010
L Only 10.910
S Only 2.520
.
Maximum Deflections for Load Combinations
Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance
D Only 0.0000 in 0.000 ft 0.0000 in 0.000 ft
+D+L 0.0000 in 0.000 ft 0.0000 in 0.000 ft
+D+Lr 0.0000 in 0.000 ft 0.0000 in 0.000 ft
+D+S 0.0000 in 0.000 ft 0.0000 in 0.000 ft
+D+0.750Lr+0.750L 0.0000 in 0.000 ft 0.0000 in 0.000 ft
+D+0.750L+0.750S 0.0000 in 0.000 ft 0.0000 in 0.000 ft
+0.60D 0.0000 in 0.000 ft 0.0000 in 0.000 ft
Lr Only 0.0000 in 0.000 ft 0.0000 in 0.000 ft
L Only 0.0000 in 0.000 ft 0.0000 in 0.000 ft
S Only 0.0000 in 0.000 ft 0.0000 in 0.000 ft
.
Sketches
Title Block Line 1 Project Title:
04/24/22 Page 79 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 5:20PM
File: Paisley Loft Calcs.ec6
Wood Column Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: P Level 1 trimmer stud at big office entry hdr
.
Code References
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Analysis Method : Allowable Stress Design Wood Section Name 3-2x6
End Fixities Top & Bottom Pinned Wood Grading/Manuf. Graded Lumber
Overall Column Height 10 ft Wood Member Type Sawn
( Used for non-slender calculations )
Exact Width 4.50 in Allow Stress Modification Factors
Wood Species Douglas Fir-Larch
Exact Depth 5.50 in Cf or Cv for Bending 1.30
Wood Grade No.2
Area 24.750 in^2 Cf or Cv for Compression 1.10
Fb + 900psi Fv 180 psi Ix 62.391 in^4 Cf or Cv for Tension 1.30
Fb - 900psi Ft 575 psi Iy 41.766 in^4 Cm : Wet Use Factor 1.0
Fc - Prll 1350psi Density 31.21 pcf
Ct : Temperature Factor 1.0
Fc - Perp 625psi
Cfu : Flat Use Factor 1.0
E : Modulus of Elasticity . . . x-x Bending y-y Bending Axial
Kf : Built-up columns 1.0 NDS 15.3.2
Basic 1600 1600 1600ksi Use Cr : Repetitive ? No
Minimum 580 580 Brace condition for deflection (buckling) along columns :
X-X (width) axis : Fully braced against buckling ABOUT Y-Y Axis
Y-Y (depth) axis : Unbraced Length for buckling ABOUT X-X Axis = 10 ft, K = 1.0
.
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Column self weight included : 53.642 lbs * Dead Load Factor
AXIAL LOADS . . .
Axial Load at 10.0 ft, D = 3.750, L = 11.250 k
.
DESIGN SUMMARY
Bending & Shear Check Results
PASS Max. Axial+Bending Stress Ratio = 0.7524 : 1 Maximum SERVICE Lateral Load Reactions . .
Load Combination +D+L Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k
Governing NDS Forumla Comp Only, fc/Fc' Top along X-X 0.0 k Bottom along X-X 0.0 k
Location of max.above base 0.0 ft
Maximum SERVICE Load Lateral Deflections . . .
At maximum location values are . . .
Along Y-Y 0.0 in at 0.0 ft above base
Applied Axial 15.054k
for load combination : n/a
Applied Mx 0.0 k-ft
Along X-X 0.0 in at 0.0 ft above base
Applied My 0.0 k-ft
Fc : Allowable 808.37 psi for load combination : n/a
Other Factors used to calculate allowable stresses . . .
PASS Maximum Shear Stress Ratio = 0.0 : 1 Bending Compression Tension
Load Combination +0.60D
Location of max.above base 10.0 ft
Applied Design Shear 0.0 psi
Allowable Shear 288.0 psi
.
Load Combination Results
Maximum Axial + Bending Stress Ratios Maximum Shear Ratios
Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location
D Only 0.900 0.585 0.1967 PASS 0.0ft 0.0 PASS 10.0 ft
+D+L 1.000 0.544 0.7524 PASS 0.0ft 0.0 PASS 10.0 ft
+D+0.750L 1.250 0.461 0.5782 PASS 0.0ft 0.0 PASS 10.0 ft
+0.60D 1.600 0.376 0.1032 PASS 0.0ft 0.0 PASS 10.0 ft
.
Maximum Reactions Note: Only non-zero reactions are listed.
X-X Axis Reaction k Y-Y Axis Reaction Axial Reaction My - End Moments k-ft Mx - End Moments
Load Combination @ Base @ Top @ Base @ Top @ Base @ Base @ Top @ Base @ Top
D Only 3.804
+D+L 15.054
+D+0.750L 12.241
Title Block Line 1 Project Title:
04/24/22 Page 80 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 5:20PM
File: Paisley Loft Calcs.ec6
Wood Column Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: P Level 1 trimmer stud at big office entry hdr
Maximum Reactions Note: Only non-zero reactions are listed.
X-X Axis Reaction k Y-Y Axis Reaction Axial Reaction My - End Moments k-ft Mx - End Moments
Load Combination @ Base @ Top @ Base @ Top @ Base @ Base @ Top @ Base @ Top
+0.60D 2.282
L Only 11.250
.
Maximum Deflections for Load Combinations
Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance
D Only 0.0000 in 0.000 ft 0.0000 in 0.000 ft
+D+L 0.0000 in 0.000 ft 0.0000 in 0.000 ft
+D+0.750L 0.0000 in 0.000 ft 0.0000 in 0.000 ft
+0.60D 0.0000 in 0.000 ft 0.0000 in 0.000 ft
L Only 0.0000 in 0.000 ft 0.0000 in 0.000 ft
.
Sketches
Title Block Line 1 Project Title:
04/24/22 Page 81 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 14 APR 2022, 9:47AM
File: Paisley Loft Calcs.ec6
Steel Column Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: P Level 1 West Parking Side Column
.
Code References
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Steel Section Name : HSS5x5x1/2 Overall Column Height 12.50 ft
Analysis Method : Load Resistance Factor Top & Bottom Fixity Top & Bottom Pinned
Steel Stress Grade Brace condition for deflection (buckling) along columns :
ft
Fy : Steel Yield 46.0 ksi X-X (width) axis :
E : Elastic Bending Modulus 29,000.0 ksi Unbraced Length for buckling ABOUT Y-Y Axis = 12.50 ft, K = 1.0
Y-Y (depth) axis :
Unbraced Length for buckling ABOUT X-X Axis = 12.50 ft, K = 1.0
.
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Column self weight included : 355.375 lbs * Dead Load Factor
AXIAL LOADS . . .
Axial Load at 12.50 ft, Xecc = 1.0 in, Yecc = 1.250 in, D = 25.230, LR = 3.950, L = 22.240, S = 4.90 k
BENDING LOADS . . .
Lat. Point Load at 2.250 ft creating Mx-x, L = 6.0 k
.
DESIGN SUMMARY
Bending & Shear Check Results
PASS Max. Axial+Bending Stress Ratio = 0.6755 : 1 Maximum Load Reactions . .
Load Combination +1.20D+1.60L+0.50S Top along X-X 0.3165 k
Location of max.above base 2.265 ft Bottom along X-X 0.3165 k
At maximum location values are . . . Top along Y-Y 1.476 k
Pu 68.736 k Bottom along Y-Y 4.735 k
(see tab for all)
0.9 * Pn 206.579 k
Mu-x 16.397 k-ft Maximum Load Deflections . . .
0.9 * Mn-x : 45.195 k-ft Along Y-Y 0.2509 in at 5.117ft above base
for load combination :L Only
Mu-y -1.032 k-ft
0.9 * Mn-y : 45.195 k-ft Along X-X -0.09166 in at 7.299ft above base
for load combination :+D+L
PASS Maximum Shear Stress Ratio = 0.1053 : 1
Load Combination +1.20D+0.50Lr+1.60L
Location of max.above base 0.0 ft
At maximum location values are . . .
Vu : Applied 7.307 k
Vn * Phi : Allowable 69.40 k
.
Load Combination Results
Maximum Axial + Bending Stress Ratios Maximum Shear Ratios
Load Combination Stress Ratio Status Location Cbx Cby KxLx/Rx KyLy/Ry Stress Ratio Status Location
+1.40D 0.232 PASS 12.42 ft 1.68 1.66 82.42 82.42 0.004 PASS 0.00 ft
+1.20D+0.50Lr+1.60L 0.673 PASS 2.27 ft 1.68 1.66 82.42 82.42 0.105 PASS 0.00 ft
+1.20D+1.60L+0.50S 0.676 PASS 2.27 ft 1.68 1.66 82.42 82.42 0.105 PASS 0.00 ft
+1.20D+1.60Lr+L 0.501 PASS 12.42 ft 1.68 1.66 82.42 82.42 0.064 PASS 0.00 ft
+1.20D+1.60Lr 0.240 PASS 12.42 ft 1.68 1.66 82.42 82.42 0.004 PASS 0.00 ft
+1.20D+L+1.60S 0.514 PASS 12.42 ft 1.68 1.66 82.42 82.42 0.064 PASS 0.00 ft
+1.20D+1.60S 0.250 PASS 12.42 ft 1.68 1.66 82.42 82.42 0.005 PASS 0.00 ft
+1.20D+0.50Lr+L 0.479 PASS 2.27 ft 1.68 1.66 82.42 82.42 0.064 PASS 0.00 ft
+1.20D+L+0.50S 0.481 PASS 2.27 ft 1.68 1.66 82.42 82.42 0.064 PASS 0.00 ft
+0.90D 0.149 PASS 12.42 ft 1.68 1.66 82.42 82.42 0.003 PASS 0.00 ft
+1.20D+L+0.20S 0.474 PASS 2.27 ft 1.68 1.66 82.42 82.42 0.064 PASS 0.00 ft
.
Maximum Reactions Note: Only non-zero reactions are listed.
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
D Only 25.585 0.168 0.168 -0.210 0.210
+D+L 47.825 0.316 0.316 4.524 1.476
Title Block Line 1 Project Title:
04/24/22 Page 82 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 14 APR 2022, 9:47AM
File: Paisley Loft Calcs.ec6
Steel Column Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: P Level 1 West Parking Side Column
Maximum Reactions Note: Only non-zero reactions are listed.
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
+D+Lr 29.535 0.195 0.195 -0.243 0.243
+D+S 30.485 0.201 0.201 -0.251 0.251
+D+0.750Lr+0.750L 45.228 0.299 0.299 3.316 1.184
+D+0.750L+0.750S 45.940 0.304 0.304 3.310 1.190
+0.60D 15.351 0.101 0.101 -0.126 0.126
Lr Only 3.950 0.026 0.026 -0.033 0.033
L Only 22.240 0.148 0.148 4.735 1.265
S Only 4.900 0.033 0.033 -0.041 0.041
Extreme Reactions
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Item Extreme Value @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
Axial @ Base Maximum 47.825 0.316 0.316 4.524 1.476
" Minimum 3.950 0.026 0.026 -0.033 0.033
Reaction, X-X Axis Base Maximum 47.825 0.316 0.316 4.524 1.476
" Minimum 3.950 0.026 0.026 -0.033 0.033
Reaction, Y-Y Axis Base Maximum 22.240 0.148 0.148 4.735 1.265
" Minimum 30.485 0.201 0.201 -0.251 0.251
Reaction, X-X Axis Top Maximum 47.825 0.316 0.316 4.524 1.476
" Minimum 3.950 0.026 0.026 -0.033 0.033
Reaction, Y-Y Axis Top Maximum 47.825 0.316 0.316 4.524 1.476
" Minimum 4.900 0.033 0.033 -0.041 0.041
Moment, X-X Axis Base Maximum 25.585 0.168 -0.210 0.210
" Minimum 25.585 0.168 -0.210 0.210
Moment, Y-Y Axis Base Maximum 25.585 0.168 0.168 -0.210 0.210
" Minimum 25.585 0.168 0.168 -0.210 0.210
Moment, X-X Axis Top Maximum 25.585 0.168 0.168 -0.210 0.210
" Minimum 25.585 0.168 0.168 -0.210 0.210
Moment, Y-Y Axis Top Maximum 25.585 0.168 0.168 -0.210 0.210
" Minimum 25.585 0.168 0.168 -0.210 0.210
.
Maximum Deflections for Load Combinations
Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance
D Only -0.0487 in 7.299 ft -0.061 in 7.299 ft
+D+L -0.0917 in 7.299 ft 0.199 in 4.698 ft
+D+Lr -0.0563 in 7.299 ft -0.070 in 7.299 ft
+D+S -0.0582 in 7.299 ft -0.073 in 7.299 ft
+D+0.750Lr+0.750L -0.0866 in 7.299 ft 0.131 in 4.446 ft
+D+0.750L+0.750S -0.0880 in 7.299 ft 0.129 in 4.446 ft
+0.60D -0.0292 in 7.299 ft -0.037 in 7.299 ft
Lr Only -0.0076 in 7.299 ft -0.010 in 7.299 ft
L Only -0.0429 in 7.299 ft 0.251 in 5.117 ft
S Only -0.0095 in 7.299 ft -0.012 in 7.299 ft
.
Steel Section Properties : HSS5x5x1/2
Title Block Line 1 Project Title:
04/24/22 Page 83 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 14 APR 2022, 9:47AM
File: Paisley Loft Calcs.ec6
Steel Column Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: P Level 1 West Parking Side Column
Steel Section Properties : HSS5x5x1/2
Depth = 5.000 in I xx = 26.00 in^4 J = 44.600 in^4
Design Thick = 0.465 in S xx = 10.40 in^3
Width = 5.000 in R xx = 1.820 in
Wall Thick = 0.500 in Zx = 13.100 in^3
Area = 7.880 in^2 I yy = 26.000 in^4 C = 18.700 in^3
Weight = 28.430 plf S yy = 10.400 in^3
R yy = 1.820 in
Ycg = 0.000 in
Sketches
Title Block Line 1 Project Title:
04/24/22 Page 84 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 4:44PM
File: Paisley Loft Calcs.ec6
Steel Column Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: P Level 1 column supporting beam over small office
.
Code References
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Steel Section Name : HSS5x5x1/4 Overall Column Height 12 ft
Analysis Method : Load Resistance Factor Top & Bottom Fixity Top & Bottom Pinned
Steel Stress Grade Brace condition for deflection (buckling) along columns :
ft
Fy : Steel Yield 46.0 ksi X-X (width) axis :
E : Elastic Bending Modulus 29,000.0 ksi Unbraced Length for buckling ABOUT Y-Y Axis = 12 ft, K = 1.0
Y-Y (depth) axis :
Unbraced Length for buckling ABOUT X-X Axis = 12 ft, K = 1.0
.
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Column self weight included : 187.440 lbs * Dead Load Factor
AXIAL LOADS . . .
Axial Load at 12.0 ft, Xecc = 2.0 in, Yecc = 2.0 in, D = 8.80, LR = 1.930, L = 10.940, S = 2.420 k
.
DESIGN SUMMARY
Bending & Shear Check Results
PASS Max. Axial+Bending Stress Ratio = 0.5691 : 1 Maximum Load Reactions . .
Load Combination +1.20D+1.60L+0.50S Top along X-X 0.2742 k
Location of max.above base 11.919 ft Bottom along X-X 0.2742 k
At maximum location values are . . . Top along Y-Y 0.2742 k
Pu 29.499 k Bottom along Y-Y 0.2742 k
(see tab for all)
0.9 * Pn 122.416 k
Mu-x -4.846 k-ft Maximum Load Deflections . . .
0.9 * Mn-x : 26.255 k-ft Along Y-Y -0.1142 in at 7.007ft above base
for load combination :+D+L
Mu-y -4.846 k-ft
0.9 * Mn-y : 26.255 k-ft Along X-X -0.1142 in at 7.007ft above base
for load combination :+D+L
PASS Maximum Shear Stress Ratio = 0.00980 : 1
Load Combination +1.20D+1.60L+0.50S
Location of max.above base 0.0 ft
At maximum location values are . . .
Vu : Applied 0.4066 k
Vn * Phi : Allowable 41.488 k
.
Load Combination Results
Maximum Axial + Bending Stress Ratios Maximum Shear Ratios
Load Combination Stress Ratio Status Location Cbx Cby KxLx/Rx KyLy/Ry Stress Ratio Status Location
+1.40D 0.207 PASS 11.92 ft 1.66 1.66 74.61 74.61 0.004 PASS 0.00 ft
+1.20D+0.50Lr+1.60L 0.564 PASS 11.92 ft 1.66 1.66 74.61 74.61 0.010 PASS 0.00 ft
+1.20D+1.60L+0.50S 0.569 PASS 11.92 ft 1.66 1.66 74.61 74.61 0.010 PASS 0.00 ft
+1.20D+1.60Lr+L 0.478 PASS 11.92 ft 1.66 1.66 74.61 74.61 0.008 PASS 0.00 ft
+1.20D+1.60Lr 0.229 PASS 11.92 ft 1.66 1.66 74.61 74.61 0.005 PASS 0.00 ft
+1.20D+L+1.60S 0.494 PASS 11.92 ft 1.66 1.66 74.61 74.61 0.008 PASS 0.00 ft
+1.20D+1.60S 0.242 PASS 11.92 ft 1.66 1.66 74.61 74.61 0.005 PASS 0.00 ft
+1.20D+0.50Lr+L 0.376 PASS 11.92 ft 1.66 1.66 74.61 74.61 0.008 PASS 0.00 ft
+1.20D+L+0.50S 0.380 PASS 11.92 ft 1.66 1.66 74.61 74.61 0.008 PASS 0.00 ft
+0.90D 0.133 PASS 11.92 ft 1.66 1.66 74.61 74.61 0.003 PASS 0.00 ft
+1.20D+L+0.20S 0.368 PASS 11.92 ft 1.66 1.66 74.61 74.61 0.007 PASS 0.00 ft
.
Maximum Reactions Note: Only non-zero reactions are listed.
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
D Only 8.987 0.122 0.122 -0.122 0.122
+D+L 19.927 0.274 0.274 -0.274 0.274
+D+Lr 10.917 0.149 0.149 -0.149 0.149
+D+S 11.407 0.156 0.156 -0.156 0.156
Title Block Line 1 Project Title:
04/24/22 Page 85 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 4:44PM
File: Paisley Loft Calcs.ec6
Steel Column Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: P Level 1 column supporting beam over small office
Maximum Reactions Note: Only non-zero reactions are listed.
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
+D+0.750Lr+0.750L 18.640 0.256 0.256 -0.256 0.256
+D+0.750L+0.750S 19.007 0.261 0.261 -0.261 0.261
+0.60D 5.392 0.073 0.073 -0.073 0.073
Lr Only 1.930 0.027 0.027 -0.027 0.027
L Only 10.940 0.152 0.152 -0.152 0.152
S Only 2.420 0.034 0.034 -0.034 0.034
Extreme Reactions
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Item Extreme Value @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
Axial @ Base Maximum 19.927 0.274 0.274 -0.274 0.274
" Minimum 1.930 0.027 0.027 -0.027 0.027
Reaction, X-X Axis Base Maximum 19.927 0.274 0.274 -0.274 0.274
" Minimum 1.930 0.027 0.027 -0.027 0.027
Reaction, Y-Y Axis Base Maximum 1.930 0.027 0.027 -0.027 0.027
" Minimum 19.927 0.274 0.274 -0.274 0.274
Reaction, X-X Axis Top Maximum 19.927 0.274 0.274 -0.274 0.274
" Minimum 1.930 0.027 0.027 -0.027 0.027
Reaction, Y-Y Axis Top Maximum 19.927 0.274 0.274 -0.274 0.274
" Minimum 1.930 0.027 0.027 -0.027 0.027
Moment, X-X Axis Base Maximum 8.987 0.122 -0.122 0.122
" Minimum 8.987 0.122 -0.122 0.122
Moment, Y-Y Axis Base Maximum 8.987 0.122 0.122 -0.122 0.122
" Minimum 8.987 0.122 0.122 -0.122 0.122
Moment, X-X Axis Top Maximum 8.987 0.122 0.122 -0.122 0.122
" Minimum 8.987 0.122 0.122 -0.122 0.122
Moment, Y-Y Axis Top Maximum 8.987 0.122 0.122 -0.122 0.122
" Minimum 8.987 0.122 0.122 -0.122 0.122
.
Maximum Deflections for Load Combinations
Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance
D Only -0.0509 in 7.007 ft -0.051 in 7.007 ft
+D+L -0.1142 in 7.007 ft -0.114 in 7.007 ft
+D+Lr -0.0621 in 7.007 ft -0.062 in 7.007 ft
+D+S -0.0649 in 7.007 ft -0.065 in 7.007 ft
+D+0.750Lr+0.750L -0.1067 in 7.007 ft -0.107 in 7.007 ft
+D+0.750L+0.750S -0.1088 in 7.007 ft -0.109 in 7.007 ft
+0.60D -0.0305 in 7.007 ft -0.031 in 7.007 ft
Lr Only -0.0112 in 7.007 ft -0.011 in 7.007 ft
L Only -0.0633 in 7.007 ft -0.063 in 7.007 ft
S Only -0.0140 in 7.007 ft -0.014 in 7.007 ft
.
Steel Section Properties : HSS5x5x1/4
Depth = 5.000 in I xx = 16.00 in^4 J = 25.800 in^4
Design Thick = 0.233 in S xx = 6.41 in^3
Width = 5.000 in R xx = 1.930 in
Wall Thick = 0.250 in Zx = 7.610 in^3
Area = 4.300 in^2 I yy = 16.000 in^4 C = 10.500 in^3
Weight = 15.620 plf S yy = 6.410 in^3
R yy = 1.930 in
Ycg = 0.000 in
Title Block Line 1 Project Title:
04/24/22 Page 86 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 4:44PM
File: Paisley Loft Calcs.ec6
Steel Column Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: P Level 1 column supporting beam over small office
Sketches
Title Block Line 1 Project Title:
04/24/22 Page 87 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 14 APR 2022, 9:47AM
File: Paisley Loft Calcs.ec6
Steel Column Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: P Level 1 West Parking Central Column
.
Code References
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Steel Section Name : HSS6x6x5/8 Overall Column Height 12.50 ft
Analysis Method : Load Resistance Factor Top & Bottom Fixity Top & Bottom Pinned
Steel Stress Grade Brace condition for deflection (buckling) along columns :
ft
Fy : Steel Yield 46.0 ksi X-X (width) axis :
E : Elastic Bending Modulus 29,000.0 ksi Unbraced Length for buckling ABOUT Y-Y Axis = 12.50 ft, K = 1.0
Y-Y (depth) axis :
Unbraced Length for buckling ABOUT X-X Axis = 12.50 ft, K = 1.0
.
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Column self weight included : 528.75 lbs * Dead Load Factor
AXIAL LOADS . . .
Axial Load at 12.50 ft, Xecc = 2.0 in, Yecc = 2.0 in, D = 52.20, LR = 8.190, L = 41.560, S = 10.10 k
BENDING LOADS . . .
Lat. Point Load at 2.250 ft creating Mx-x, L = 6.0 k
.
DESIGN SUMMARY
Bending & Shear Check Results
PASS Max. Axial+Bending Stress Ratio = 0.8756 : 1 Maximum Load Reactions . .
Load Combination +1.20D+1.60L+0.50S Top along X-X 1.250 k
Location of max.above base 12.416 ft Bottom along X-X 1.250 k
At maximum location values are . . . Top along Y-Y 2.330 k
Pu 134.821 k Bottom along Y-Y 4.366 k
(see tab for all)
0.9 * Pn 351.234 k
Mu-x -22.069 k-ft Maximum Load Deflections . . .
0.9 * Mn-x : 80.040 k-ft Along Y-Y -0.1133 in at 7.299ft above base
for load combination :+D+S
Mu-y -22.214 k-ft
0.9 * Mn-y : 80.040 k-ft Along X-X -0.1705 in at 7.299ft above base
for load combination :+D+L
PASS Maximum Shear Stress Ratio = 0.05953 : 1
Load Combination +1.20D+0.50Lr+1.60L
Location of max.above base 0.0 ft
At maximum location values are . . .
Vu : Applied 6.096 k
Vn * Phi : Allowable 102.395 k
.
Load Combination Results
Maximum Axial + Bending Stress Ratios Maximum Shear Ratios
Load Combination Stress Ratio Status Location Cbx Cby KxLx/Rx KyLy/Ry Stress Ratio Status Location
+1.40D 0.479 PASS 12.42 ft 1.85 1.66 69.12 69.12 0.010 PASS 0.00 ft
+1.20D+0.50Lr+1.60L 0.869 PASS 12.42 ft 1.85 1.66 69.12 69.12 0.060 PASS 0.00 ft
+1.20D+1.60L+0.50S 0.876 PASS 12.42 ft 1.85 1.66 69.12 69.12 0.059 PASS 0.00 ft
+1.20D+1.60Lr+L 0.766 PASS 12.42 ft 1.85 1.66 69.12 69.12 0.033 PASS 0.00 ft
+1.20D+1.60Lr 0.496 PASS 12.42 ft 1.85 1.66 69.12 69.12 0.010 PASS 0.00 ft
+1.20D+L+1.60S 0.786 PASS 12.42 ft 1.85 1.66 69.12 69.12 0.032 PASS 0.00 ft
+1.20D+1.60S 0.516 PASS 12.42 ft 1.85 1.66 69.12 69.12 0.010 PASS 0.00 ft
+1.20D+0.50Lr+L 0.707 PASS 12.42 ft 1.85 1.66 69.12 69.12 0.034 PASS 0.00 ft
+1.20D+L+0.50S 0.714 PASS 12.42 ft 1.85 1.66 69.12 69.12 0.034 PASS 0.00 ft
+0.90D 0.262 PASS 12.42 ft 1.85 1.66 69.12 69.12 0.006 PASS 0.00 ft
+1.20D+L+0.20S 0.694 PASS 12.42 ft 1.85 1.66 69.12 69.12 0.034 PASS 0.00 ft
.
Maximum Reactions Note: Only non-zero reactions are listed.
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
D Only 52.729 0.696 0.696 -0.696 0.696
+D+L 94.289 1.250 1.250 3.670 2.330
Title Block Line 1 Project Title:
04/24/22 Page 88 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 14 APR 2022, 9:47AM
File: Paisley Loft Calcs.ec6
Steel Column Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: P Level 1 West Parking Central Column
Maximum Reactions Note: Only non-zero reactions are listed.
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
+D+Lr 60.919 0.805 0.805 -0.805 0.805
+D+S 62.829 0.831 0.831 -0.831 0.831
+D+0.750Lr+0.750L 90.041 1.194 1.194 2.497 2.004
+D+0.750L+0.750S 91.474 1.213 1.213 2.477 2.023
+0.60D 31.637 0.418 0.418 -0.418 0.418
Lr Only 8.190 0.109 0.109 -0.109 0.109
L Only 41.560 0.554 0.554 4.366 1.634
S Only 10.100 0.135 0.135 -0.135 0.135
Extreme Reactions
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Item Extreme Value @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
Axial @ Base Maximum 94.289 1.250 1.250 3.670 2.330
" Minimum 8.190 0.109 0.109 -0.109 0.109
Reaction, X-X Axis Base Maximum 94.289 1.250 1.250 3.670 2.330
" Minimum 8.190 0.109 0.109 -0.109 0.109
Reaction, Y-Y Axis Base Maximum 41.560 0.554 0.554 4.366 1.634
" Minimum 62.829 0.831 0.831 -0.831 0.831
Reaction, X-X Axis Top Maximum 94.289 1.250 1.250 3.670 2.330
" Minimum 8.190 0.109 0.109 -0.109 0.109
Reaction, Y-Y Axis Top Maximum 94.289 1.250 1.250 3.670 2.330
" Minimum 8.190 0.109 0.109 -0.109 0.109
Moment, X-X Axis Base Maximum 52.729 0.696 -0.696 0.696
" Minimum 52.729 0.696 -0.696 0.696
Moment, Y-Y Axis Base Maximum 52.729 0.696 0.696 -0.696 0.696
" Minimum 52.729 0.696 0.696 -0.696 0.696
Moment, X-X Axis Top Maximum 52.729 0.696 0.696 -0.696 0.696
" Minimum 52.729 0.696 0.696 -0.696 0.696
Moment, Y-Y Axis Top Maximum 52.729 0.696 0.696 -0.696 0.696
" Minimum 52.729 0.696 0.696 -0.696 0.696
.
Maximum Deflections for Load Combinations
Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance
D Only -0.0950 in 7.299 ft -0.095 in 7.299 ft
+D+L -0.1705 in 7.299 ft -0.058 in 9.396 ft
+D+Lr -0.1098 in 7.299 ft -0.110 in 7.299 ft
+D+S -0.1133 in 7.299 ft -0.113 in 7.299 ft
+D+0.750Lr+0.750L -0.1628 in 7.299 ft -0.075 in 8.809 ft
+D+0.750L+0.750S -0.1654 in 7.299 ft -0.077 in 8.809 ft
+0.60D -0.0570 in 7.299 ft -0.057 in 7.299 ft
Lr Only -0.0149 in 7.299 ft -0.015 in 7.299 ft
L Only -0.0756 in 7.299 ft 0.076 in 4.279 ft
S Only -0.0184 in 7.299 ft -0.018 in 7.299 ft
.
Steel Section Properties : HSS6x6x5/8
Title Block Line 1 Project Title:
04/24/22 Page 89 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 14 APR 2022, 9:47AM
File: Paisley Loft Calcs.ec6
Steel Column Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: P Level 1 West Parking Central Column
Steel Section Properties : HSS6x6x5/8
Depth = 6.000 in I xx = 55.20 in^4 J = 94.900 in^4
Design Thick = 0.581 in S xx = 18.40 in^3
Width = 6.000 in R xx = 2.170 in
Wall Thick = 0.624 in Zx = 23.200 in^3
Area = 11.700 in^2 I yy = 55.200 in^4 C = 33.400 in^3
Weight = 42.300 plf S yy = 18.400 in^3
R yy = 2.170 in
Ycg = 0.000 in
Sketches
Title Block Line 1 Project Title:
04/24/22 Page 90 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 5:24PM
File: Paisley Loft Calcs.ec6
Steel Column Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: P Level 1 column in Big office
.
Code References
Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Steel Section Name : HSS5x5x1/4 Overall Column Height 12 ft
Analysis Method : Load Resistance Factor Top & Bottom Fixity Top & Bottom Pinned
Steel Stress Grade Brace condition for deflection (buckling) along columns :
ft
Fy : Steel Yield 46.0 ksi X-X (width) axis :
E : Elastic Bending Modulus 29,000.0 ksi Unbraced Length for buckling ABOUT Y-Y Axis = 12 ft, K = 1.0
Y-Y (depth) axis :
Unbraced Length for buckling ABOUT X-X Axis = 12 ft, K = 1.0
.
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Column self weight included : 187.440 lbs * Dead Load Factor
AXIAL LOADS . . .
Axial Load at 12.0 ft, D = 15.0, L = 30.0 k
.
DESIGN SUMMARY
Bending & Shear Check Results
PASS Max. Axial+Bending Stress Ratio = 0.5410 : 1 Maximum Load Reactions . .
Load Combination +1.20D+1.60L Top along X-X 0.0 k
Location of max.above base 0.0 ft Bottom along X-X 0.0 k
At maximum location values are . . . Top along Y-Y 0.0 k
Pu 66.225 k Bottom along Y-Y 0.0 k
(see tab for all)
0.9 * Pn 122.416 k
Mu-x 0.0 k-ft Maximum Load Deflections . . .
0.9 * Mn-x : 26.255 k-ft Along Y-Y 0.0 in at 0.0ft above base
for load combination :
Mu-y 0.0 k-ft
0.9 * Mn-y : 26.255 k-ft Along X-X 0.0 in at 0.0ft above base
for load combination :
PASS Maximum Shear Stress Ratio = 0.0 : 1
Load Combination 0.0
Location of max.above base 0.0 ft
At maximum location values are . . .
Vu : Applied 0.0 k
Vn * Phi : Allowable 0.0 k
.
Load Combination Results
Maximum Axial + Bending Stress Ratios Maximum Shear Ratios
Load Combination Stress Ratio Status Location Cbx Cby KxLx/Rx KyLy/Ry Stress Ratio Status Location
+1.40D 0.174 PASS 0.00 ft 1.00 1.00 74.61 74.61 0.000 PASS 0.00 ft
+1.20D+1.60L 0.541 PASS 0.00 ft 1.00 1.00 74.61 74.61 0.000 PASS 0.00 ft
+1.20D+L 0.394 PASS 0.00 ft 1.00 1.00 74.61 74.61 0.000 PASS 0.00 ft
+1.20D 0.149 PASS 0.00 ft 1.00 1.00 74.61 74.61 0.000 PASS 0.00 ft
+0.90D 0.112 PASS 0.00 ft 1.00 1.00 74.61 74.61 0.000 PASS 0.00 ft
.
Maximum Reactions Note: Only non-zero reactions are listed.
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
D Only 15.187
+D+L 45.187
+D+0.750L 37.687
+0.60D 9.112
L Only 30.000
Extreme Reactions
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Item Extreme Value @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
Axial @ Base Maximum 45.187
Title Block Line 1 Project Title:
04/24/22 Page 91 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 5:24PM
File: Paisley Loft Calcs.ec6
Steel Column Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: P Level 1 column in Big office
Extreme Reactions
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
Item Extreme Value @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
" Minimum 9.112
Reaction, X-X Axis Base Maximum 15.187
" Minimum 15.187
Reaction, Y-Y Axis Base Maximum 15.187
" Minimum 15.187
Reaction, X-X Axis Top Maximum 15.187
" Minimum 15.187
Reaction, Y-Y Axis Top Maximum 15.187
" Minimum 15.187
Moment, X-X Axis Base Maximum 15.187
" Minimum 15.187
Moment, Y-Y Axis Base Maximum 15.187
" Minimum 15.187
Moment, X-X Axis Top Maximum 15.187
" Minimum 15.187
Moment, Y-Y Axis Top Maximum 15.187
" Minimum 15.187
.
Maximum Deflections for Load Combinations
Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance
D Only 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+L 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+0.750L 0.0000 in 0.000 ft 0.000 in 0.000 ft
+0.60D 0.0000 in 0.000 ft 0.000 in 0.000 ft
L Only 0.0000 in 0.000 ft 0.000 in 0.000 ft
.
Steel Section Properties : HSS5x5x1/4
Depth = 5.000 in I xx = 16.00 in^4 J = 25.800 in^4
Design Thick = 0.233 in S xx = 6.41 in^3
Width = 5.000 in R xx = 1.930 in
Wall Thick = 0.250 in Zx = 7.610 in^3
Area = 4.300 in^2 I yy = 16.000 in^4 C = 10.500 in^3
Weight = 15.620 plf S yy = 6.410 in^3
R yy = 1.930 in
Ycg = 0.000 in
Title Block Line 1 Project Title:
04/24/22 Page 92 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 13 APR 2022, 5:24PM
File: Paisley Loft Calcs.ec6
Steel Column Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: P Level 1 column in Big office
Sketches
Title Block Line 1 Project Title:
04/24/22 Page 93 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 15 APR 2022, 12:20PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level 1 Center West parking footing
Code References
Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Material Properties Soil Design Values
f'c : Concrete 28 day strength = 3.0 ksi Allowable Soil Bearing = 1.50 ksf
fy : Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = No
Ec : Concrete Elastic Modulus = 3,122.0 ksi Soil Passive Resistance (for Sliding) = 250.0 pcf
Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. = 0.30
Values Flexure = 0.90
Shear = 0.750 Increases based on footing Depth
Analysis Settings Footing base depth below soil surface = 1.50 ft
Min Steel % Bending Reinf. = Allow press. increase per foot of depth = 1.0 ksf
Min Allow % Temp Reinf. = 0.00180 when footing base is below = 1.0 ft
Min. Overturning Safety Factor = 1.0 : 1
Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension
Add Ftg Wt for Soil Pressure : Yes Allowable pressure increase per foot of depth
Use ftg wt for stability, moments & shears : Yes = ksf
when max. length or width is greater than
Add Pedestal Wt for Soil Pressure : No
= ft
Use Pedestal wt for stability, mom & shear : No
Dimensions
Width parallel to X-X Axis = 8.0 ft
Length parallel to Z-Z Axis = 8.0 ft
Footing Thickness = 18 in
Pedestal dimensions...
px : parallel to X-X Axis = 0.0 in
pz : parallel to Z-Z Axis = 0.0 in
=
Height 0.0 in
Rebar Centerline to Edge of Concrete...
at Bottom of footing = 3.0 in
Reinforcing
Bars parallel to X-X Axis
Number of Bars = 12
Reinforcing Bar Size = # 5
Bars parallel to Z-Z Axis
Number of Bars = 12
Reinforcing Bar Size = # 5
Bandwidth Distribution Check (ACI 15.4.4.2)
Direction Requiring Closer Separation
n/a
# Bars required within zone n/a
# Bars required on each side of zone n/a
Applied Loads
D Lr L S W E H
P : Column Load = 52.80 8.20 41.560 10.10 k
OB : Overburden = ksf
M-xx = k-ft
M-zz = k-ft
V-x = k
V-z = k
Title Block Line 1 Project Title:
04/24/22 Page 94 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 15 APR 2022, 12:20PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level 1 Center West parking footing
DESIGN SUMMARY Design OK
Min. Ratio Item Applied Capacity Governing Load Combination
PASS 0.8460 Soil Bearing 1.692 ksf 2.0 ksf +D+L about Z-Z axis
PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding
PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding
PASS n/a Uplift 0.0 k 0.0 k No Uplift
PASS 0.5541 Z Flexure (+X) 16.863 k-ft/ft 30.434 k-ft/ft +1.20D+1.60L+0.50S
PASS 0.5541 Z Flexure (-X) 16.863 k-ft/ft 30.434 k-ft/ft +1.20D+1.60L+0.50S
PASS 0.5541 X Flexure (+Z) 16.863 k-ft/ft 30.434 k-ft/ft +1.20D+1.60L+0.50S
PASS 0.5541 X Flexure (-Z) 16.863 k-ft/ft 30.434 k-ft/ft +1.20D+1.60L+0.50S
PASS 0.3877 1-way Shear (+X) 31.853 psi 82.158 psi +1.20D+1.60L+0.50S
PASS 0.3877 1-way Shear (-X) 31.853 psi 82.158 psi +1.20D+1.60L+0.50S
PASS 0.3877 1-way Shear (+Z) 31.853 psi 82.158 psi +1.20D+1.60L+0.50S
PASS 0.3877 1-way Shear (-Z) 31.853 psi 82.158 psi +1.20D+1.60L+0.50S
PASS 0.8889 2-way Punching 146.058 psi 164.317 psi +1.20D+1.60L+0.50S
Detailed Results
Soil Bearing
Rotation Axis & Xecc Zecc Actual Soil Bearing Stress @ Location Actual / Allow
Load Combination... Gross Allowable (in) Bottom, -Z Top, +Z Left, -X Right, +X Ratio
X-X, D Only 2.0 n/a 0.0 1.043 1.043 n/a n/a 0.522
X-X, +D+L 2.0 n/a 0.0 1.692 1.692 n/a n/a 0.846
X-X, +D+Lr 2.0 n/a 0.0 1.171 1.171 n/a n/a 0.586
X-X, +D+S 2.0 n/a 0.0 1.20 1.20 n/a n/a 0.600
X-X, +D+0.750Lr+0.750L 2.0 n/a 0.0 1.626 1.626 n/a n/a 0.813
X-X, +D+0.750L+0.750S 2.0 n/a 0.0 1.648 1.648 n/a n/a 0.824
X-X, +0.60D 2.0 n/a 0.0 0.6255 0.6255 n/a n/a 0.313
Z-Z, D Only 2.0 0.0 n/a n/a n/a 1.043 1.043 0.522
Z-Z, +D+L 2.0 0.0 n/a n/a n/a 1.692 1.692 0.846
Z-Z, +D+Lr 2.0 0.0 n/a n/a n/a 1.171 1.171 0.586
Z-Z, +D+S 2.0 0.0 n/a n/a n/a 1.20 1.20 0.600
Z-Z, +D+0.750Lr+0.750L 2.0 0.0 n/a n/a n/a 1.626 1.626 0.813
Z-Z, +D+0.750L+0.750S 2.0 0.0 n/a n/a n/a 1.648 1.648 0.824
Z-Z, +0.60D 2.0 0.0 n/a n/a n/a 0.6255 0.6255 0.313
Overturning Stability
Rotation Axis &
Load Combination... Overturning Moment Resisting Moment Stability Ratio Status
Footing Has NO Overturning
All units k
Sliding Stability
Force Application Axis
Load Combination... Sliding Force Resisting Force Stability Ratio Status
Footing Has NO Sliding
Footing Flexure
Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status
k-ft Surface in^2 in^2 in^2 k-ft
X-X, +1.40D 9.240 +Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.40D 9.240 -Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+0.50Lr+1.60L 16.745 +Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+0.50Lr+1.60L 16.745 -Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+1.60L+0.50S 16.863 +Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+1.60L+0.50S 16.863 -Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+1.60Lr+L 14.755 +Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+1.60Lr+L 14.755 -Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+1.60Lr 9.560 +Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+1.60Lr 9.560 -Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Title Block Line 1 Project Title:
04/24/22 Page 95 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 15 APR 2022, 12:20PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level 1 Center West parking footing
Footing Flexure
Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status
k-ft Surface in^2 in^2 in^2 k-ft
X-X, +1.20D+L+1.60S 15.135 +Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+L+1.60S 15.135 -Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+1.60S 9.940 +Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+1.60S 9.940 -Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+0.50Lr+L 13.628 +Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+0.50Lr+L 13.628 -Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+L+0.50S 13.746 +Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+L+0.50S 13.746 -Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +0.90D 5.940 +Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +0.90D 5.940 -Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+L+0.20S 13.368 +Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
X-X, +1.20D+L+0.20S 13.368 -Z Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.40D 9.240 -X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.40D 9.240 +X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+0.50Lr+1.60L 16.745 -X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+0.50Lr+1.60L 16.745 +X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+1.60L+0.50S 16.863 -X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+1.60L+0.50S 16.863 +X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+1.60Lr+L 14.755 -X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+1.60Lr+L 14.755 +X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+1.60Lr 9.560 -X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+1.60Lr 9.560 +X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+L+1.60S 15.135 -X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+L+1.60S 15.135 +X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+1.60S 9.940 -X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+1.60S 9.940 +X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+0.50Lr+L 13.628 -X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+0.50Lr+L 13.628 +X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+L+0.50S 13.746 -X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+L+0.50S 13.746 +X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +0.90D 5.940 -X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +0.90D 5.940 +X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+L+0.20S 13.368 -X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
Z-Z, +1.20D+L+0.20S 13.368 +X Bottom 0.3888 Min Temp % 0.4650 30.434 OK
One Way Shear
Load Combination... Vu @ -X Vu @ +X Vu @ -Z Vu @ +Z Vu:Max Phi Vn Vu / Phi*Vn Status
+1.40D 17.45psi 17.45psi 17.45 psi 17.45 psi 17.45psi 82.16 psi 0.21 OK
+1.20D+0.50Lr+1.60L 31.63psi 31.63psi 31.63 psi 31.63 psi 31.63psi 82.16 psi 0.39 OK
+1.20D+1.60L+0.50S 31.85psi 31.85psi 31.85 psi 31.85 psi 31.85psi 82.16 psi 0.39 OK
+1.20D+1.60Lr+L 27.87psi 27.87psi 27.87 psi 27.87 psi 27.87psi 82.16 psi 0.34 OK
+1.20D+1.60Lr 18.06psi 18.06psi 18.06 psi 18.06 psi 18.06psi 82.16 psi 0.22 OK
+1.20D+L+1.60S 28.59psi 28.59psi 28.59 psi 28.59 psi 28.59psi 82.16 psi 0.35 OK
+1.20D+1.60S 18.78psi 18.78psi 18.78 psi 18.78 psi 18.78psi 82.16 psi 0.23 OK
+1.20D+0.50Lr+L 25.74psi 25.74psi 25.74 psi 25.74 psi 25.74psi 82.16 psi 0.31 OK
+1.20D+L+0.50S 25.97psi 25.97psi 25.97 psi 25.97 psi 25.97psi 82.16 psi 0.32 OK
+0.90D 11.22psi 11.22psi 11.22 psi 11.22 psi 11.22psi 82.16 psi 0.14 OK
+1.20D+L+0.20S 25.25psi 25.25psi 25.25 psi 25.25 psi 25.25psi 82.16 psi 0.31 OK
Two-Way "Punching" Shear All units k
Load Combination... Vu Phi*Vn Vu / Phi*Vn Status
+1.40D 80.03 psi 164.32psi 0.4871 OK
+1.20D+0.50Lr+1.60L 145.03 psi 164.32psi 0.8826 OK
+1.20D+1.60L+0.50S 146.06 psi 164.32psi 0.8889 OK
+1.20D+1.60Lr+L 127.80 psi 164.32psi 0.7778 OK
+1.20D+1.60Lr 82.80 psi 164.32psi 0.5039 OK
+1.20D+L+1.60S 131.09 psi 164.32psi 0.7978 OK
+1.20D+1.60S 86.09 psi 164.32psi 0.5239 OK
+1.20D+0.50Lr+L 118.03 psi 164.32psi 0.7183 OK
+1.20D+L+0.50S 119.06 psi 164.32psi 0.7246 OK
+0.90D 51.45 psi 164.32psi 0.3131 OK
+1.20D+L+0.20S 115.78 psi 164.32psi 0.7046 OK
Title Block Line 1 Project Title:
04/24/22 Page 96 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 20 APR 2022, 1:42PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level 1 Edge West parking footing
Code References
Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Material Properties Soil Design Values
f'c : Concrete 28 day strength = 3.0 ksi Allowable Soil Bearing = 1.50 ksf
fy : Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = No
Ec : Concrete Elastic Modulus = 3,122.0 ksi Soil Passive Resistance (for Sliding) = 250.0 pcf
Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. = 0.30
Values Flexure = 0.90
Shear = 0.750 Increases based on footing Depth
Analysis Settings Footing base depth below soil surface = 1.50 ft
Min Steel % Bending Reinf. = Allow press. increase per foot of depth = 1.0 ksf
Min Allow % Temp Reinf. = 0.00180 when footing base is below = 1.0 ft
Min. Overturning Safety Factor = 1.0 : 1
Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension
Add Ftg Wt for Soil Pressure : Yes Allowable pressure increase per foot of depth
Use ftg wt for stability, moments & shears : Yes = ksf
when max. length or width is greater than
Add Pedestal Wt for Soil Pressure : No
= ft
Use Pedestal wt for stability, mom & shear : No
Dimensions
Width parallel to X-X Axis = 6.0 ft
Length parallel to Z-Z Axis = 6.0 ft
Footing Thickness = 16.0 in
Pedestal dimensions...
px : parallel to X-X Axis = in
pz : parallel to Z-Z Axis = in
=
Height in
Rebar Centerline to Edge of Concrete...
at Bottom of footing = 3.0 in
Reinforcing
Bars parallel to X-X Axis
Number of Bars = 8.0
Reinforcing Bar Size = # 5
Bars parallel to Z-Z Axis
Number of Bars = 8.0
Reinforcing Bar Size = # 5
Bandwidth Distribution Check (ACI 15.4.4.2)
Direction Requiring Closer Separation
n/a
# Bars required within zone n/a
# Bars required on each side of zone n/a
Applied Loads
D Lr L S W E H
P : Column Load = 25.50 8.20 22.240 5.0 k
OB : Overburden = ksf
M-xx = k-ft
M-zz = k-ft
V-x = k
V-z = k
Title Block Line 1 Project Title:
04/24/22 Page 97 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 20 APR 2022, 1:42PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level 1 Edge West parking footing
DESIGN SUMMARY Design OK
Min. Ratio Item Applied Capacity Governing Load Combination
PASS 0.7770 Soil Bearing 1.554 ksf 2.0 ksf +D+0.750Lr+0.750L about Z-Z axis
PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding
PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding
PASS n/a Uplift 0.0 k 0.0 k No Uplift
PASS 0.3750 Z Flexure (+X) 8.786 k-ft/ft 23.426 k-ft/ft +1.20D+0.50Lr+1.60L
PASS 0.3750 Z Flexure (-X) 8.786 k-ft/ft 23.426 k-ft/ft +1.20D+0.50Lr+1.60L
PASS 0.3750 X Flexure (+Z) 8.786 k-ft/ft 23.426 k-ft/ft +1.20D+0.50Lr+1.60L
PASS 0.3750 X Flexure (-Z) 8.786 k-ft/ft 23.426 k-ft/ft +1.20D+0.50Lr+1.60L
PASS 0.2925 1-way Shear (+X) 24.029 psi 82.158 psi +1.20D+0.50Lr+1.60L
PASS 0.2925 1-way Shear (-X) 24.029 psi 82.158 psi +1.20D+0.50Lr+1.60L
PASS 0.2925 1-way Shear (+Z) 24.029 psi 82.158 psi +1.20D+0.50Lr+1.60L
PASS 0.2925 1-way Shear (-Z) 24.029 psi 82.158 psi +1.20D+0.50Lr+1.60L
PASS 0.6122 2-way Punching 100.602 psi 164.317 psi +1.20D+0.50Lr+1.60L
Detailed Results
Soil Bearing
Rotation Axis & Xecc Zecc Actual Soil Bearing Stress @ Location Actual / Allow
Load Combination... Gross Allowable (in) Bottom, -Z Top, +Z Left, -X Right, +X Ratio
X-X, D Only 2.0 n/a 0.0 0.920 0.920 n/a n/a 0.460
X-X, +D+L 2.0 n/a 0.0 1.538 1.538 n/a n/a 0.769
X-X, +D+Lr 2.0 n/a 0.0 1.148 1.148 n/a n/a 0.574
X-X, +D+S 2.0 n/a 0.0 1.059 1.059 n/a n/a 0.530
X-X, +D+0.750Lr+0.750L 2.0 n/a 0.0 1.554 1.554 n/a n/a 0.777
X-X, +D+0.750L+0.750S 2.0 n/a 0.0 1.488 1.488 n/a n/a 0.744
X-X, +0.60D 2.0 n/a 0.0 0.5520 0.5520 n/a n/a 0.276
Z-Z, D Only 2.0 0.0 n/a n/a n/a 0.920 0.920 0.460
Z-Z, +D+L 2.0 0.0 n/a n/a n/a 1.538 1.538 0.769
Z-Z, +D+Lr 2.0 0.0 n/a n/a n/a 1.148 1.148 0.574
Z-Z, +D+S 2.0 0.0 n/a n/a n/a 1.059 1.059 0.530
Z-Z, +D+0.750Lr+0.750L 2.0 0.0 n/a n/a n/a 1.554 1.554 0.777
Z-Z, +D+0.750L+0.750S 2.0 0.0 n/a n/a n/a 1.488 1.488 0.744
Z-Z, +0.60D 2.0 0.0 n/a n/a n/a 0.5520 0.5520 0.276
Overturning Stability
Rotation Axis &
Load Combination... Overturning Moment Resisting Moment Stability Ratio Status
Footing Has NO Overturning
All units k
Sliding Stability
Force Application Axis
Load Combination... Sliding Force Resisting Force Stability Ratio Status
Footing Has NO Sliding
Footing Flexure
Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status
k-ft Surface in^2 in^2 in^2 k-ft
X-X, +1.40D 4.463 +Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.40D 4.463 -Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+0.50Lr+1.60L 8.786 +Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+0.50Lr+1.60L 8.786 -Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+1.60L+0.50S 8.586 +Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+1.60L+0.50S 8.586 -Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+1.60Lr+L 8.245 +Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+1.60Lr+L 8.245 -Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+1.60Lr 5.465 +Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+1.60Lr 5.465 -Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Title Block Line 1 Project Title:
04/24/22 Page 98 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 20 APR 2022, 1:42PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level 1 Edge West parking footing
Footing Flexure
Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status
k-ft Surface in^2 in^2 in^2 k-ft
X-X, +1.20D+L+1.60S 7.605 +Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+L+1.60S 7.605 -Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+1.60S 4.825 +Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+1.60S 4.825 -Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+0.50Lr+L 7.118 +Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+0.50Lr+L 7.118 -Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+L+0.50S 6.918 +Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+L+0.50S 6.918 -Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +0.90D 2.869 +Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +0.90D 2.869 -Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+L+0.20S 6.730 +Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
X-X, +1.20D+L+0.20S 6.730 -Z Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.40D 4.463 -X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.40D 4.463 +X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+0.50Lr+1.60L 8.786 -X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+0.50Lr+1.60L 8.786 +X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+1.60L+0.50S 8.586 -X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+1.60L+0.50S 8.586 +X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+1.60Lr+L 8.245 -X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+1.60Lr+L 8.245 +X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+1.60Lr 5.465 -X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+1.60Lr 5.465 +X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+L+1.60S 7.605 -X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+L+1.60S 7.605 +X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+1.60S 4.825 -X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+1.60S 4.825 +X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+0.50Lr+L 7.118 -X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+0.50Lr+L 7.118 +X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+L+0.50S 6.918 -X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+L+0.50S 6.918 +X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +0.90D 2.869 -X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +0.90D 2.869 +X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+L+0.20S 6.730 -X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
Z-Z, +1.20D+L+0.20S 6.730 +X Bottom 0.3456 Min Temp % 0.4133 23.426 OK
One Way Shear
Load Combination... Vu @ -X Vu @ +X Vu @ -Z Vu @ +Z Vu:Max Phi Vn Vu / Phi*Vn Status
+1.40D 12.21psi 12.21psi 12.21 psi 12.21 psi 12.21psi 82.16 psi 0.15 OK
+1.20D+0.50Lr+1.60L 24.03psi 24.03psi 24.03 psi 24.03 psi 24.03psi 82.16 psi 0.29 OK
+1.20D+1.60L+0.50S 23.48psi 23.48psi 23.48 psi 23.48 psi 23.48psi 82.16 psi 0.29 OK
+1.20D+1.60Lr+L 22.55psi 22.55psi 22.55 psi 22.55 psi 22.55psi 82.16 psi 0.27 OK
+1.20D+1.60Lr 14.95psi 14.95psi 14.95 psi 14.95 psi 14.95psi 82.16 psi 0.18 OK
+1.20D+L+1.60S 20.80psi 20.80psi 20.80 psi 20.80 psi 20.80psi 82.16 psi 0.25 OK
+1.20D+1.60S 13.20psi 13.20psi 13.20 psi 13.20 psi 13.20psi 82.16 psi 0.16 OK
+1.20D+0.50Lr+L 19.47psi 19.47psi 19.47 psi 19.47 psi 19.47psi 82.16 psi 0.24 OK
+1.20D+L+0.50S 18.92psi 18.92psi 18.92 psi 18.92 psi 18.92psi 82.16 psi 0.23 OK
+0.90D 7.85psi 7.85psi 7.85 psi 7.85 psi 7.85psi 82.16 psi 0.10 OK
+1.20D+L+0.20S 18.41psi 18.41psi 18.41 psi 18.41 psi 18.41psi 82.16 psi 0.22 OK
Two-Way "Punching" Shear All units k
Load Combination... Vu Phi*Vn Vu / Phi*Vn Status
+1.40D 51.10 psi 164.32psi 0.311 OK
+1.20D+0.50Lr+1.60L 100.60 psi 164.32psi 0.6122 OK
+1.20D+1.60L+0.50S 98.31 psi 164.32psi 0.5983 OK
+1.20D+1.60Lr+L 94.41 psi 164.32psi 0.5746 OK
+1.20D+1.60Lr 62.58 psi 164.32psi 0.3808 OK
+1.20D+L+1.60S 87.08 psi 164.32psi 0.53 OK
+1.20D+1.60S 55.25 psi 164.32psi 0.3362 OK
+1.20D+0.50Lr+L 81.50 psi 164.32psi 0.496 OK
+1.20D+L+0.50S 79.21 psi 164.32psi 0.4821 OK
+0.90D 32.85 psi 164.32psi 0.1999 OK
+1.20D+L+0.20S 77.06 psi 164.32psi 0.469 OK
Title Block Line 1 Project Title:
04/24/22 Page 99 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 4:59PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level central Footing in big office
Code References
Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Material Properties Soil Design Values
f'c : Concrete 28 day strength = 3.0 ksi Allowable Soil Bearing = 1.50 ksf
fy : Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = No
Ec : Concrete Elastic Modulus = 3,122.0 ksi Soil Passive Resistance (for Sliding) = 250.0 pcf
Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. = 0.30
Values Flexure = 0.90
Shear = 0.750 Increases based on footing Depth
Analysis Settings Footing base depth below soil surface = 1.50 ft
Min Steel % Bending Reinf. = Allow press. increase per foot of depth = 1.0 ksf
Min Allow % Temp Reinf. = 0.00180 when footing base is below = 1.0 ft
Min. Overturning Safety Factor = 1.0 : 1
Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension
Add Ftg Wt for Soil Pressure : Yes Allowable pressure increase per foot of depth
Use ftg wt for stability, moments & shears : Yes = ksf
when max. length or width is greater than
Add Pedestal Wt for Soil Pressure : No
= ft
Use Pedestal wt for stability, mom & shear : No
Dimensions
Width parallel to X-X Axis = 6.0 ft
Length parallel to Z-Z Axis = 6.0 ft
Footing Thickness = 14.0 in
Pedestal dimensions...
px : parallel to X-X Axis = in
pz : parallel to Z-Z Axis = in
=
Height in
Rebar Centerline to Edge of Concrete...
at Bottom of footing = 3.0 in
Reinforcing
Bars parallel to X-X Axis
Number of Bars = 8
Reinforcing Bar Size = # 5
Bars parallel to Z-Z Axis
Number of Bars = 8
Reinforcing Bar Size = # 5
Bandwidth Distribution Check (ACI 15.4.4.2)
Direction Requiring Closer Separation
n/a
# Bars required within zone n/a
# Bars required on each side of zone n/a
Applied Loads
D Lr L S W E H
P : Column Load = 15 0.0 30.0 0.0 k
OB : Overburden = ksf
M-xx = k-ft
M-zz = k-ft
V-x = k
V-z = k
Title Block Line 1 Project Title:
04/24/22 Page 100 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 4:59PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level central Footing in big office
DESIGN SUMMARY Design OK
Min. Ratio Item Applied Capacity Governing Load Combination
PASS 0.7280 Soil Bearing 1.456 ksf 2.0 ksf +D+L about Z-Z axis
PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding
PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding
PASS n/a Uplift 0.0 k 0.0 k No Uplift
PASS 0.4186 Z Flexure (+X) 8.250 k-ft/ft 19.706 k-ft/ft +1.20D+1.60L
PASS 0.4186 Z Flexure (-X) 8.250 k-ft/ft 19.706 k-ft/ft +1.20D+1.60L
PASS 0.4186 X Flexure (+Z) 8.250 k-ft/ft 19.706 k-ft/ft +1.20D+1.60L
PASS 0.4186 X Flexure (-Z) 8.250 k-ft/ft 19.706 k-ft/ft +1.20D+1.60L
PASS 0.3550 1-way Shear (+X) 29.167 psi 82.158 psi +1.20D+1.60L
PASS 0.3550 1-way Shear (-X) 29.167 psi 82.158 psi +1.20D+1.60L
PASS 0.3550 1-way Shear (+Z) 29.167 psi 82.158 psi +1.20D+1.60L
PASS 0.3550 1-way Shear (-Z) 29.167 psi 82.158 psi +1.20D+1.60L
PASS 0.8086 2-way Punching 132.873 psi 164.317 psi +1.20D+1.60L
Detailed Results
Soil Bearing
Rotation Axis & Xecc Zecc Actual Soil Bearing Stress @ Location Actual / Allow
Load Combination... Gross Allowable (in) Bottom, -Z Top, +Z Left, -X Right, +X Ratio
X-X, D Only 2.0 n/a 0.0 0.6225 0.6225 n/a n/a 0.311
X-X, +D+L 2.0 n/a 0.0 1.456 1.456 n/a n/a 0.728
X-X, +D+0.750L 2.0 n/a 0.0 1.248 1.248 n/a n/a 0.624
X-X, +0.60D 2.0 n/a 0.0 0.3735 0.3735 n/a n/a 0.187
Z-Z, D Only 2.0 0.0 n/a n/a n/a 0.6225 0.6225 0.311
Z-Z, +D+L 2.0 0.0 n/a n/a n/a 1.456 1.456 0.728
Z-Z, +D+0.750L 2.0 0.0 n/a n/a n/a 1.248 1.248 0.624
Z-Z, +0.60D 2.0 0.0 n/a n/a n/a 0.3735 0.3735 0.187
Overturning Stability
Rotation Axis &
Load Combination... Overturning Moment Resisting Moment Stability Ratio Status
Footing Has NO Overturning
All units k
Sliding Stability
Force Application Axis
Load Combination... Sliding Force Resisting Force Stability Ratio Status
Footing Has NO Sliding
Footing Flexure
Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status
k-ft Surface in^2 in^2 in^2 k-ft
X-X, +1.40D 2.625 +Z Bottom 0.3024 Min Temp % 0.4133 19.706 OK
X-X, +1.40D 2.625 -Z Bottom 0.3024 Min Temp % 0.4133 19.706 OK
X-X, +1.20D+1.60L 8.250 +Z Bottom 0.3024 Min Temp % 0.4133 19.706 OK
X-X, +1.20D+1.60L 8.250 -Z Bottom 0.3024 Min Temp % 0.4133 19.706 OK
X-X, +1.20D+L 6.0 +Z Bottom 0.3024 Min Temp % 0.4133 19.706 OK
X-X, +1.20D+L 6.0 -Z Bottom 0.3024 Min Temp % 0.4133 19.706 OK
X-X, +1.20D 2.250 +Z Bottom 0.3024 Min Temp % 0.4133 19.706 OK
X-X, +1.20D 2.250 -Z Bottom 0.3024 Min Temp % 0.4133 19.706 OK
X-X, +0.90D 1.688 +Z Bottom 0.3024 Min Temp % 0.4133 19.706 OK
X-X, +0.90D 1.688 -Z Bottom 0.3024 Min Temp % 0.4133 19.706 OK
Z-Z, +1.40D 2.625 -X Bottom 0.3024 Min Temp % 0.4133 19.706 OK
Z-Z, +1.40D 2.625 +X Bottom 0.3024 Min Temp % 0.4133 19.706 OK
Z-Z, +1.20D+1.60L 8.250 -X Bottom 0.3024 Min Temp % 0.4133 19.706 OK
Z-Z, +1.20D+1.60L 8.250 +X Bottom 0.3024 Min Temp % 0.4133 19.706 OK
Z-Z, +1.20D+L 6.0 -X Bottom 0.3024 Min Temp % 0.4133 19.706 OK
Z-Z, +1.20D+L 6.0 +X Bottom 0.3024 Min Temp % 0.4133 19.706 OK
Title Block Line 1 Project Title:
04/24/22 Page 101 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 4:59PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level central Footing in big office
Footing Flexure
Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status
k-ft Surface in^2 in^2 in^2 k-ft
Z-Z, +1.20D 2.250 -X Bottom 0.3024 Min Temp % 0.4133 19.706 OK
Z-Z, +1.20D 2.250 +X Bottom 0.3024 Min Temp % 0.4133 19.706 OK
Z-Z, +0.90D 1.688 -X Bottom 0.3024 Min Temp % 0.4133 19.706 OK
Z-Z, +0.90D 1.688 +X Bottom 0.3024 Min Temp % 0.4133 19.706 OK
One Way Shear
Load Combination... Vu @ -X Vu @ +X Vu @ -Z Vu @ +Z Vu:Max Phi Vn Vu / Phi*Vn Status
+1.40D 9.28psi 9.28psi 9.28 psi 9.28 psi 9.28psi 82.16 psi 0.11 OK
+1.20D+1.60L 29.17psi 29.17psi 29.17 psi 29.17 psi 29.17psi 82.16 psi 0.36 OK
+1.20D+L 21.21psi 21.21psi 21.21 psi 21.21 psi 21.21psi 82.16 psi 0.26 OK
+1.20D 7.96psi 7.96psi 7.96 psi 7.96 psi 7.96psi 82.16 psi 0.10 OK
+0.90D 5.97psi 5.97psi 5.97 psi 5.97 psi 5.97psi 82.16 psi 0.07 OK
Two-Way "Punching" Shear All units k
Load Combination... Vu Phi*Vn Vu / Phi*Vn Status
+1.40D 42.28 psi 164.32psi 0.2573 OK
+1.20D+1.60L 132.87 psi 164.32psi 0.8086 OK
+1.20D+L 96.64 psi 164.32psi 0.5881 OK
+1.20D 36.24 psi 164.32psi 0.2205 OK
+0.90D 27.18 psi 164.32psi 0.1654 OK
Title Block Line 1 Project Title:
04/24/22 Page 102 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 4:52PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level Footing in small office
Code References
Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Material Properties Soil Design Values
f'c : Concrete 28 day strength = 3.0 ksi Allowable Soil Bearing = 1.50 ksf
fy : Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = No
Ec : Concrete Elastic Modulus = 3,122.0 ksi Soil Passive Resistance (for Sliding) = 250.0 pcf
Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. = 0.30
Values Flexure = 0.90
Shear = 0.750 Increases based on footing Depth
Analysis Settings Footing base depth below soil surface = 1.50 ft
Min Steel % Bending Reinf. = Allow press. increase per foot of depth = 1.0 ksf
Min Allow % Temp Reinf. = 0.00180 when footing base is below = 1.0 ft
Min. Overturning Safety Factor = 1.0 : 1
Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension
Add Ftg Wt for Soil Pressure : Yes Allowable pressure increase per foot of depth
Use ftg wt for stability, moments & shears : Yes = ksf
when max. length or width is greater than
Add Pedestal Wt for Soil Pressure : No
= ft
Use Pedestal wt for stability, mom & shear : No
Dimensions
Width parallel to X-X Axis = 5.0 ft
Length parallel to Z-Z Axis = 5.0 ft
Footing Thickness = 12.0 in
Pedestal dimensions...
px : parallel to X-X Axis = 0 in
pz : parallel to Z-Z Axis = 0.0 in
=
Height 0.0 in
Rebar Centerline to Edge of Concrete...
at Bottom of footing = 3.0 in
Reinforcing
Bars parallel to X-X Axis
Number of Bars = 6
Reinforcing Bar Size = # 5
Bars parallel to Z-Z Axis
Number of Bars = 6
Reinforcing Bar Size = # 5
Bandwidth Distribution Check (ACI 15.4.4.2)
Direction Requiring Closer Separation
n/a
# Bars required within zone n/a
# Bars required on each side of zone n/a
Applied Loads
D Lr L S W E H
P : Column Load = 16.4 3.480 17.70 4.350 k
OB : Overburden = ksf
M-xx = k-ft
M-zz = k-ft
V-x = k
V-z = k
Title Block Line 1 Project Title:
04/24/22 Page 103 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 4:52PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level Footing in small office
DESIGN SUMMARY Design OK
Min. Ratio Item Applied Capacity Governing Load Combination
PASS 0.7820 Soil Bearing 1.564 ksf 2.0 ksf +D+L about Z-Z axis
PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding
PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding
PASS n/a Uplift 0.0 k 0.0 k No Uplift
PASS 0.4339 Z Flexure (+X) 6.272 k-ft/ft 14.455 k-ft/ft +1.20D+1.60L+0.50S
PASS 0.4339 Z Flexure (-X) 6.272 k-ft/ft 14.455 k-ft/ft +1.20D+1.60L+0.50S
PASS 0.4339 X Flexure (+Z) 6.272 k-ft/ft 14.455 k-ft/ft +1.20D+1.60L+0.50S
PASS 0.4339 X Flexure (-Z) 6.272 k-ft/ft 14.455 k-ft/ft +1.20D+1.60L+0.50S
PASS 0.3958 1-way Shear (+X) 32.521 psi 82.158 psi +1.20D+1.60L+0.50S
PASS 0.3958 1-way Shear (-X) 32.521 psi 82.158 psi +1.20D+1.60L+0.50S
PASS 0.3958 1-way Shear (+Z) 32.521 psi 82.158 psi +1.20D+1.60L+0.50S
PASS 0.3958 1-way Shear (-Z) 32.521 psi 82.158 psi +1.20D+1.60L+0.50S
PASS 0.9212 2-way Punching 151.377 psi 164.317 psi +1.20D+1.60L+0.50S
Detailed Results
Soil Bearing
Rotation Axis & Xecc Zecc Actual Soil Bearing Stress @ Location Actual / Allow
Load Combination... Gross Allowable (in) Bottom, -Z Top, +Z Left, -X Right, +X Ratio
X-X, D Only 2.0 n/a 0.0 0.8560 0.8560 n/a n/a 0.428
X-X, +D+L 2.0 n/a 0.0 1.564 1.564 n/a n/a 0.782
X-X, +D+Lr 2.0 n/a 0.0 0.9952 0.9952 n/a n/a 0.498
X-X, +D+S 2.0 n/a 0.0 1.030 1.030 n/a n/a 0.515
X-X, +D+0.750Lr+0.750L 2.0 n/a 0.0 1.491 1.491 n/a n/a 0.746
X-X, +D+0.750L+0.750S 2.0 n/a 0.0 1.518 1.518 n/a n/a 0.759
X-X, +0.60D 2.0 n/a 0.0 0.5136 0.5136 n/a n/a 0.257
Z-Z, D Only 2.0 0.0 n/a n/a n/a 0.8560 0.8560 0.428
Z-Z, +D+L 2.0 0.0 n/a n/a n/a 1.564 1.564 0.782
Z-Z, +D+Lr 2.0 0.0 n/a n/a n/a 0.9952 0.9952 0.498
Z-Z, +D+S 2.0 0.0 n/a n/a n/a 1.030 1.030 0.515
Z-Z, +D+0.750Lr+0.750L 2.0 0.0 n/a n/a n/a 1.491 1.491 0.746
Z-Z, +D+0.750L+0.750S 2.0 0.0 n/a n/a n/a 1.518 1.518 0.759
Z-Z, +0.60D 2.0 0.0 n/a n/a n/a 0.5136 0.5136 0.257
Overturning Stability
Rotation Axis &
Load Combination... Overturning Moment Resisting Moment Stability Ratio Status
Footing Has NO Overturning
All units k
Sliding Stability
Force Application Axis
Load Combination... Sliding Force Resisting Force Stability Ratio Status
Footing Has NO Sliding
Footing Flexure
Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status
k-ft Surface in^2 in^2 in^2 k-ft
X-X, +1.40D 2.870 +Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.40D 2.870 -Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+0.50Lr+1.60L 6.218 +Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+0.50Lr+1.60L 6.218 -Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+1.60L+0.50S 6.272 +Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+1.60L+0.50S 6.272 -Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+1.60Lr+L 5.369 +Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+1.60Lr+L 5.369 -Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+1.60Lr 3.156 +Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+1.60Lr 3.156 -Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Title Block Line 1 Project Title:
04/24/22 Page 104 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 19 APR 2022, 4:52PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level Footing in small office
Footing Flexure
Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status
k-ft Surface in^2 in^2 in^2 k-ft
X-X, +1.20D+L+1.60S 5.543 +Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+L+1.60S 5.543 -Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+1.60S 3.330 +Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+1.60S 3.330 -Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+0.50Lr+L 4.890 +Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+0.50Lr+L 4.890 -Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+L+0.50S 4.944 +Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+L+0.50S 4.944 -Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +0.90D 1.845 +Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +0.90D 1.845 -Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+L+0.20S 4.781 +Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
X-X, +1.20D+L+0.20S 4.781 -Z Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.40D 2.870 -X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.40D 2.870 +X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+0.50Lr+1.60L 6.218 -X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+0.50Lr+1.60L 6.218 +X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+1.60L+0.50S 6.272 -X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+1.60L+0.50S 6.272 +X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+1.60Lr+L 5.369 -X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+1.60Lr+L 5.369 +X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+1.60Lr 3.156 -X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+1.60Lr 3.156 +X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+L+1.60S 5.543 -X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+L+1.60S 5.543 +X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+1.60S 3.330 -X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+1.60S 3.330 +X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+0.50Lr+L 4.890 -X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+0.50Lr+L 4.890 +X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+L+0.50S 4.944 -X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+L+0.50S 4.944 +X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +0.90D 1.845 -X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +0.90D 1.845 +X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+L+0.20S 4.781 -X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
Z-Z, +1.20D+L+0.20S 4.781 +X Bottom 0.2592 Min Temp % 0.3720 14.455 OK
One Way Shear
Load Combination... Vu @ -X Vu @ +X Vu @ -Z Vu @ +Z Vu:Max Phi Vn Vu / Phi*Vn Status
+1.40D 14.88psi 14.88psi 14.88 psi 14.88 psi 14.88psi 82.16 psi 0.18 OK
+1.20D+0.50Lr+1.60L 32.24psi 32.24psi 32.24 psi 32.24 psi 32.24psi 82.16 psi 0.39 OK
+1.20D+1.60L+0.50S 32.52psi 32.52psi 32.52 psi 32.52 psi 32.52psi 82.16 psi 0.40 OK
+1.20D+1.60Lr+L 27.84psi 27.84psi 27.84 psi 27.84 psi 27.84psi 82.16 psi 0.34 OK
+1.20D+1.60Lr 16.36psi 16.36psi 16.36 psi 16.36 psi 16.36psi 82.16 psi 0.20 OK
+1.20D+L+1.60S 28.74psi 28.74psi 28.74 psi 28.74 psi 28.74psi 82.16 psi 0.35 OK
+1.20D+1.60S 17.27psi 17.27psi 17.27 psi 17.27 psi 17.27psi 82.16 psi 0.21 OK
+1.20D+0.50Lr+L 25.36psi 25.36psi 25.36 psi 25.36 psi 25.36psi 82.16 psi 0.31 OK
+1.20D+L+0.50S 25.64psi 25.64psi 25.64 psi 25.64 psi 25.64psi 82.16 psi 0.31 OK
+0.90D 9.57psi 9.57psi 9.57 psi 9.57 psi 9.57psi 82.16 psi 0.12 OK
+1.20D+L+0.20S 24.79psi 24.79psi 24.79 psi 24.79 psi 24.79psi 82.16 psi 0.30 OK
Two-Way "Punching" Shear All units k
Load Combination... Vu Phi*Vn Vu / Phi*Vn Status
+1.40D 69.27 psi 164.32psi 0.4216 OK
+1.20D+0.50Lr+1.60L 150.06 psi 164.32psi 0.9133 OK
+1.20D+1.60L+0.50S 151.38 psi 164.32psi 0.9212 OK
+1.20D+1.60Lr+L 129.57 psi 164.32psi 0.7886 OK
+1.20D+1.60Lr 76.17 psi 164.32psi 0.4636 OK
+1.20D+L+1.60S 133.77 psi 164.32psi 0.8141 OK
+1.20D+1.60S 80.37 psi 164.32psi 0.4891 OK
+1.20D+0.50Lr+L 118.02 psi 164.32psi 0.7183 OK
+1.20D+L+0.50S 119.34 psi 164.32psi 0.7263 OK
+0.90D 44.53 psi 164.32psi 0.271 OK
+1.20D+L+0.20S 115.40 psi 164.32psi 0.7023 OK
Title Block Line 1 Project Title:
04/24/22 Page 105 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 15 APR 2022, 1:02PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level 1 Edge South Parking Footing
Code References
Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Material Properties Soil Design Values
f'c : Concrete 28 day strength = 3.0 ksi Allowable Soil Bearing = 1.50 ksf
fy : Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = No
Ec : Concrete Elastic Modulus = 3,122.0 ksi Soil Passive Resistance (for Sliding) = 250.0 pcf
Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. = 0.30
Values Flexure = 0.90
Shear = 0.750 Increases based on footing Depth
Analysis Settings Footing base depth below soil surface = 1.50 ft
Min Steel % Bending Reinf. = Allow press. increase per foot of depth = 1.0 ksf
Min Allow % Temp Reinf. = 0.00180 when footing base is below = 1.0 ft
Min. Overturning Safety Factor = 1.0 : 1
Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension
Add Ftg Wt for Soil Pressure : Yes Allowable pressure increase per foot of depth
Use ftg wt for stability, moments & shears : Yes = ksf
when max. length or width is greater than
Add Pedestal Wt for Soil Pressure : No
= ft
Use Pedestal wt for stability, mom & shear : No
Dimensions
Width parallel to X-X Axis = 5.0 ft
Length parallel to Z-Z Axis = 5.0 ft
Footing Thickness = 10.0 in
Pedestal dimensions...
px : parallel to X-X Axis = 8.0 in
pz : parallel to Z-Z Axis = 16.0 in
=
Height 12.0 in
Rebar Centerline to Edge of Concrete...
at Bottom of footing = 3.0 in
Reinforcing
Bars parallel to X-X Axis
Number of Bars = 7
Reinforcing Bar Size = # 5
Bars parallel to Z-Z Axis
Number of Bars = 7
Reinforcing Bar Size = # 5
Bandwidth Distribution Check (ACI 15.4.4.2)
Direction Requiring Closer Separation
n/a
# Bars required within zone n/a
# Bars required on each side of zone n/a
Applied Loads
D Lr L S W E H
P : Column Load = 18.0 4.10 16.0 5.0 k
OB : Overburden = ksf
M-xx = k-ft
M-zz = k-ft
V-x = k
V-z = k
Title Block Line 1 Project Title:
04/24/22 Page 106 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 15 APR 2022, 1:02PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level 1 Edge South Parking Footing
DESIGN SUMMARY Design OK
Min. Ratio Item Applied Capacity Governing Load Combination
PASS 0.7760 Soil Bearing 1.552 ksf 2.0 ksf +D+L about Z-Z axis
PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding
PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding
PASS n/a Uplift 0.0 k 0.0 k No Uplift
PASS 0.3628 Z Flexure (+X) 4.659 k-ft/ft 12.840 k-ft/ft +1.20D+1.60L+0.50S
PASS 0.3628 Z Flexure (-X) 4.659 k-ft/ft 12.840 k-ft/ft +1.20D+1.60L+0.50S
PASS 0.2598 X Flexure (+Z) 3.335 k-ft/ft 12.840 k-ft/ft +1.20D+1.60L+0.50S
PASS 0.2598 X Flexure (-Z) 3.335 k-ft/ft 12.840 k-ft/ft +1.20D+1.60L+0.50S
PASS 0.4602 1-way Shear (+X) 37.807 psi 82.158 psi +1.20D+1.60L+0.50S
PASS 0.4602 1-way Shear (-X) 37.807 psi 82.158 psi +1.20D+1.60L+0.50S
PASS 0.3595 1-way Shear (+Z) 29.537 psi 82.158 psi +1.20D+1.60L+0.50S
PASS 0.3595 1-way Shear (-Z) 29.537 psi 82.158 psi +1.20D+1.60L+0.50S
PASS 0.5137 2-way Punching 84.413 psi 164.317 psi +1.20D+1.60L+0.50S
Detailed Results
Soil Bearing
Rotation Axis & Xecc Zecc Actual Soil Bearing Stress @ Location Actual / Allow
Load Combination... Gross Allowable (in) Bottom, -Z Top, +Z Left, -X Right, +X Ratio
X-X, D Only 2.0 n/a 0.0 0.9116 0.9116 n/a n/a 0.456
X-X, +D+L 2.0 n/a 0.0 1.552 1.552 n/a n/a 0.776
X-X, +D+Lr 2.0 n/a 0.0 1.076 1.076 n/a n/a 0.538
X-X, +D+S 2.0 n/a 0.0 1.112 1.112 n/a n/a 0.556
X-X, +D+0.750Lr+0.750L 2.0 n/a 0.0 1.515 1.515 n/a n/a 0.758
X-X, +D+0.750L+0.750S 2.0 n/a 0.0 1.542 1.542 n/a n/a 0.771
X-X, +0.60D 2.0 n/a 0.0 0.5469 0.5469 n/a n/a 0.274
Z-Z, D Only 2.0 0.0 n/a n/a n/a 0.9116 0.9116 0.456
Z-Z, +D+L 2.0 0.0 n/a n/a n/a 1.552 1.552 0.776
Z-Z, +D+Lr 2.0 0.0 n/a n/a n/a 1.076 1.076 0.538
Z-Z, +D+S 2.0 0.0 n/a n/a n/a 1.112 1.112 0.556
Z-Z, +D+0.750Lr+0.750L 2.0 0.0 n/a n/a n/a 1.515 1.515 0.758
Z-Z, +D+0.750L+0.750S 2.0 0.0 n/a n/a n/a 1.542 1.542 0.771
Z-Z, +0.60D 2.0 0.0 n/a n/a n/a 0.5469 0.5469 0.274
Overturning Stability
Rotation Axis &
Load Combination... Overturning Moment Resisting Moment Stability Ratio Status
Footing Has NO Overturning
All units k
Sliding Stability
Force Application Axis
Load Combination... Sliding Force Resisting Force Stability Ratio Status
Footing Has NO Sliding
Footing Flexure
Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status
k-ft Surface in^2 in^2 in^2 k-ft
X-X, +1.40D 1.688 +Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.40D 1.688 -Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+0.50Lr+1.60L 3.305 +Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+0.50Lr+1.60L 3.305 -Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+1.60L+0.50S 3.335 +Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+1.60L+0.50S 3.335 -Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+1.60Lr+L 2.963 +Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+1.60Lr+L 2.963 -Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+1.60Lr 1.888 +Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+1.60Lr 1.888 -Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Title Block Line 1 Project Title:
04/24/22 Page 107 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 15 APR 2022, 1:02PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level 1 Edge South Parking Footing
Footing Flexure
Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status
k-ft Surface in^2 in^2 in^2 k-ft
X-X, +1.20D+L+1.60S 3.060 +Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+L+1.60S 3.060 -Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+1.60S 1.984 +Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+1.60S 1.984 -Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+0.50Lr+L 2.660 +Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+0.50Lr+L 2.660 -Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+L+0.50S 2.690 +Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+L+0.50S 2.690 -Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +0.90D 1.085 +Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +0.90D 1.085 -Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+L+0.20S 2.589 +Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
X-X, +1.20D+L+0.20S 2.589 -Z Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.40D 2.357 -X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.40D 2.357 +X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+0.50Lr+1.60L 4.616 -X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+0.50Lr+1.60L 4.616 +X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+1.60L+0.50S 4.659 -X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+1.60L+0.50S 4.659 +X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+1.60Lr+L 4.139 -X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+1.60Lr+L 4.139 +X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+1.60Lr 2.636 -X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+1.60Lr 2.636 +X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+L+1.60S 4.274 -X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+L+1.60S 4.274 +X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+1.60S 2.772 -X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+1.60S 2.772 +X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+0.50Lr+L 3.715 -X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+0.50Lr+L 3.715 +X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+L+0.50S 3.757 -X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+L+0.50S 3.757 +X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +0.90D 1.515 -X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +0.90D 1.515 +X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+L+0.20S 3.617 -X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
Z-Z, +1.20D+L+0.20S 3.617 +X Bottom 0.2160 Min Temp % 0.4340 12.840 OK
One Way Shear
Load Combination... Vu @ -X Vu @ +X Vu @ -Z Vu @ +Z Vu:Max Phi Vn Vu / Phi*Vn Status
+1.40D 19.13psi 19.13psi 14.95 psi 14.95 psi 19.13psi 82.16 psi 0.23 OK
+1.20D+0.50Lr+1.60L 37.46psi 37.46psi 29.27 psi 29.27 psi 37.46psi 82.16 psi 0.46 OK
+1.20D+1.60L+0.50S 37.81psi 37.81psi 29.54 psi 29.54 psi 37.81psi 82.16 psi 0.46 OK
+1.20D+1.60Lr+L 33.59psi 33.59psi 26.24 psi 26.24 psi 33.59psi 82.16 psi 0.41 OK
+1.20D+1.60Lr 21.40psi 21.40psi 16.72 psi 16.72 psi 21.40psi 82.16 psi 0.26 OK
+1.20D+L+1.60S 34.68psi 34.68psi 27.10 psi 27.10 psi 34.68psi 82.16 psi 0.42 OK
+1.20D+1.60S 22.49psi 22.49psi 17.57 psi 17.57 psi 22.49psi 82.16 psi 0.27 OK
+1.20D+0.50Lr+L 30.15psi 30.15psi 23.56 psi 23.56 psi 30.15psi 82.16 psi 0.37 OK
+1.20D+L+0.50S 30.49psi 30.49psi 23.82 psi 23.82 psi 30.49psi 82.16 psi 0.37 OK
+0.90D 12.30psi 12.30psi 9.61 psi 9.61 psi 12.30psi 82.16 psi 0.15 OK
+1.20D+L+0.20S 29.35psi 29.35psi 22.93 psi 22.93 psi 29.35psi 82.16 psi 0.36 OK
Two-Way "Punching" Shear All units k
Load Combination... Vu Phi*Vn Vu / Phi*Vn Status
+1.40D 42.71 psi 164.32psi 0.2599 OK
+1.20D+0.50Lr+1.60L 83.65 psi 164.32psi 0.5091 OK
+1.20D+1.60L+0.50S 84.41 psi 164.32psi 0.5137 OK
+1.20D+1.60Lr+L 74.99 psi 164.32psi 0.4564 OK
+1.20D+1.60Lr 47.77 psi 164.32psi 0.2907 OK
+1.20D+L+1.60S 77.44 psi 164.32psi 0.4713 OK
+1.20D+1.60S 50.22 psi 164.32psi 0.3056 OK
+1.20D+0.50Lr+L 67.32 psi 164.32psi 0.4097 OK
+1.20D+L+0.50S 68.08 psi 164.32psi 0.4143 OK
+0.90D 27.46 psi 164.32psi 0.1671 OK
+1.20D+L+0.20S 65.53 psi 164.32psi 0.3988 OK
Title Block Line 1 Project Title:
04/24/22 Page 108 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 15 APR 2022, 12:36PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level 1 South Parking Footing
Code References
Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Material Properties Soil Design Values
f'c : Concrete 28 day strength = 3.0 ksi Allowable Soil Bearing = 1.50 ksf
fy : Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = No
Ec : Concrete Elastic Modulus = 3,122.0 ksi Soil Passive Resistance (for Sliding) = 250.0 pcf
Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. = 0.30
Values Flexure = 0.90
Shear = 0.750 Increases based on footing Depth
Analysis Settings Footing base depth below soil surface = 1.50 ft
Min Steel % Bending Reinf. = Allow press. increase per foot of depth = 1.0 ksf
Min Allow % Temp Reinf. = 0.00180 when footing base is below = 1.0 ft
Min. Overturning Safety Factor = 1.0 : 1
Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension
Add Ftg Wt for Soil Pressure : Yes Allowable pressure increase per foot of depth
Use ftg wt for stability, moments & shears : Yes = ksf
when max. length or width is greater than
Add Pedestal Wt for Soil Pressure : No
= ft
Use Pedestal wt for stability, mom & shear : No
Dimensions
Width parallel to X-X Axis = 7.0 ft
Length parallel to Z-Z Axis = 7.0 ft
Footing Thickness = 18.0 in
Pedestal dimensions...
px : parallel to X-X Axis = in
pz : parallel to Z-Z Axis = 0.0 in
=
Height 0.0 in
Rebar Centerline to Edge of Concrete...
at Bottom of footing = 3.0 in
Reinforcing
Bars parallel to X-X Axis
Number of Bars = 10
Reinforcing Bar Size = # 5
Bars parallel to Z-Z Axis
Number of Bars = 10
Reinforcing Bar Size = # 5
Bandwidth Distribution Check (ACI 15.4.4.2)
Direction Requiring Closer Separation
n/a
# Bars required within zone n/a
# Bars required on each side of zone n/a
Applied Loads
D Lr L S W E H
P : Column Load = 36.7 8.20 33.660 10.0 k
OB : Overburden = ksf
M-xx = k-ft
M-zz = k-ft
V-x = k
V-z = k
Title Block Line 1 Project Title:
04/24/22 Page 109 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 15 APR 2022, 12:36PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level 1 South Parking Footing
DESIGN SUMMARY Design OK
Min. Ratio Item Applied Capacity Governing Load Combination
PASS 0.8265 Soil Bearing 1.653 ksf 2.0 ksf +D+L about Z-Z axis
PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding
PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding
PASS n/a Uplift 0.0 k 0.0 k No Uplift
PASS 0.2735 Z Flexure (+X) 7.940 k-ft/ft 29.028 k-ft/ft +1.20D+1.60L+0.50S
PASS 0.2735 Z Flexure (-X) 7.940 k-ft/ft 29.028 k-ft/ft +1.20D+1.60L+0.50S
PASS 0.4431 X Flexure (+Z) 12.862 k-ft/ft 29.028 k-ft/ft +1.20D+1.60L+0.50S
PASS 0.4431 X Flexure (-Z) 12.862 k-ft/ft 29.028 k-ft/ft +1.20D+1.60L+0.50S
PASS 0.2087 1-way Shear (+X) 17.149 psi 82.158 psi +1.20D+1.60L+0.50S
PASS 0.2087 1-way Shear (-X) 17.149 psi 82.158 psi +1.20D+1.60L+0.50S
PASS 0.3181 1-way Shear (+Z) 26.132 psi 82.158 psi +1.20D+1.60L+0.50S
PASS 0.3181 1-way Shear (-Z) 26.132 psi 82.158 psi +1.20D+1.60L+0.50S
PASS 0.4036 2-way Punching 66.311 psi 164.317 psi +1.20D+1.60L+0.50S
Detailed Results
Soil Bearing
Rotation Axis & Xecc Zecc Actual Soil Bearing Stress @ Location Actual / Allow
Load Combination... Gross Allowable (in) Bottom, -Z Top, +Z Left, -X Right, +X Ratio
X-X, D Only 2.0 n/a 0.0 0.9665 0.9665 n/a n/a 0.483
X-X, +D+L 2.0 n/a 0.0 1.653 1.653 n/a n/a 0.827
X-X, +D+Lr 2.0 n/a 0.0 1.134 1.134 n/a n/a 0.567
X-X, +D+S 2.0 n/a 0.0 1.171 1.171 n/a n/a 0.586
X-X, +D+0.750Lr+0.750L 2.0 n/a 0.0 1.607 1.607 n/a n/a 0.804
X-X, +D+0.750L+0.750S 2.0 n/a 0.0 1.635 1.635 n/a n/a 0.818
X-X, +0.60D 2.0 n/a 0.0 0.5799 0.5799 n/a n/a 0.290
Z-Z, D Only 2.0 0.0 n/a n/a n/a 0.9665 0.9665 0.483
Z-Z, +D+L 2.0 0.0 n/a n/a n/a 1.653 1.653 0.827
Z-Z, +D+Lr 2.0 0.0 n/a n/a n/a 1.134 1.134 0.567
Z-Z, +D+S 2.0 0.0 n/a n/a n/a 1.171 1.171 0.586
Z-Z, +D+0.750Lr+0.750L 2.0 0.0 n/a n/a n/a 1.607 1.607 0.804
Z-Z, +D+0.750L+0.750S 2.0 0.0 n/a n/a n/a 1.635 1.635 0.818
Z-Z, +0.60D 2.0 0.0 n/a n/a n/a 0.5799 0.5799 0.290
Overturning Stability
Rotation Axis &
Load Combination... Overturning Moment Resisting Moment Stability Ratio Status
Footing Has NO Overturning
All units k
Sliding Stability
Force Application Axis
Load Combination... Sliding Force Resisting Force Stability Ratio Status
Footing Has NO Sliding
Footing Flexure
Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status
k-ft Surface in^2 in^2 in^2 k-ft
X-X, +1.40D 6.423 +Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.40D 6.423 -Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+0.50Lr+1.60L 12.750 +Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+0.50Lr+1.60L 12.750 -Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+1.60L+0.50S 12.862 +Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+1.60L+0.50S 12.862 -Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+1.60Lr+L 11.353 +Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+1.60Lr+L 11.353 -Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+1.60Lr 7.145 +Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+1.60Lr 7.145 -Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Title Block Line 1 Project Title:
04/24/22 Page 110 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 15 APR 2022, 12:36PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level 1 South Parking Footing
Footing Flexure
Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status
k-ft Surface in^2 in^2 in^2 k-ft
X-X, +1.20D+L+1.60S 11.713 +Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+L+1.60S 11.713 -Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+1.60S 7.505 +Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+1.60S 7.505 -Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+0.50Lr+L 10.225 +Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+0.50Lr+L 10.225 -Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+L+0.50S 10.338 +Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+L+0.50S 10.338 -Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +0.90D 4.129 +Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +0.90D 4.129 -Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+L+0.20S 9.963 +Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
X-X, +1.20D+L+0.20S 9.963 -Z Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.40D 3.965 -X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.40D 3.965 +X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+0.50Lr+1.60L 7.870 -X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+0.50Lr+1.60L 7.870 +X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+1.60L+0.50S 7.940 -X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+1.60L+0.50S 7.940 +X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+1.60Lr+L 7.008 -X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+1.60Lr+L 7.008 +X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+1.60Lr 4.411 -X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+1.60Lr 4.411 +X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+L+1.60S 7.230 -X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+L+1.60S 7.230 +X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+1.60S 4.633 -X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+1.60S 4.633 +X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+0.50Lr+L 6.312 -X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+0.50Lr+L 6.312 +X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+L+0.50S 6.381 -X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+L+0.50S 6.381 +X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +0.90D 2.549 -X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +0.90D 2.549 +X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+L+0.20S 6.150 -X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
Z-Z, +1.20D+L+0.20S 6.150 +X Bottom 0.3888 Min Temp % 0.4429 29.028 OK
One Way Shear
Load Combination... Vu @ -X Vu @ +X Vu @ -Z Vu @ +Z Vu:Max Phi Vn Vu / Phi*Vn Status
+1.40D 8.56psi 8.56psi 13.05 psi 13.05 psi 13.05psi 82.16 psi 0.16 OK
+1.20D+0.50Lr+1.60L 17.00psi 17.00psi 25.90 psi 25.90 psi 25.90psi 82.16 psi 0.32 OK
+1.20D+1.60L+0.50S 17.15psi 17.15psi 26.13 psi 26.13 psi 26.13psi 82.16 psi 0.32 OK
+1.20D+1.60Lr+L 15.14psi 15.14psi 23.07 psi 23.07 psi 23.07psi 82.16 psi 0.28 OK
+1.20D+1.60Lr 9.53psi 9.53psi 14.52 psi 14.52 psi 14.52psi 82.16 psi 0.18 OK
+1.20D+L+1.60S 15.62psi 15.62psi 23.80 psi 23.80 psi 23.80psi 82.16 psi 0.29 OK
+1.20D+1.60S 10.01psi 10.01psi 15.25 psi 15.25 psi 15.25psi 82.16 psi 0.19 OK
+1.20D+0.50Lr+L 13.63psi 13.63psi 20.78 psi 20.78 psi 20.78psi 82.16 psi 0.25 OK
+1.20D+L+0.50S 13.78psi 13.78psi 21.00 psi 21.00 psi 21.00psi 82.16 psi 0.26 OK
+0.90D 5.51psi 5.51psi 8.39 psi 8.39 psi 8.39psi 82.16 psi 0.10 OK
+1.20D+L+0.20S 13.28psi 13.28psi 20.24 psi 20.24 psi 20.24psi 82.16 psi 0.25 OK
Two-Way "Punching" Shear All units k
Load Combination... Vu Phi*Vn Vu / Phi*Vn Status
+1.40D 33.11 psi 164.32psi 0.2015 OK
+1.20D+0.50Lr+1.60L 65.73 psi 164.32psi 0.4 OK
+1.20D+1.60L+0.50S 66.31 psi 164.32psi 0.4036 OK
+1.20D+1.60Lr+L 58.53 psi 164.32psi 0.3562 OK
+1.20D+1.60Lr 36.84 psi 164.32psi 0.2242 OK
+1.20D+L+1.60S 60.38 psi 164.32psi 0.3675 OK
+1.20D+1.60S 38.69 psi 164.32psi 0.2355 OK
+1.20D+0.50Lr+L 52.72 psi 164.32psi 0.3208 OK
+1.20D+L+0.50S 53.30 psi 164.32psi 0.3243 OK
+0.90D 21.29 psi 164.32psi 0.1295 OK
+1.20D+L+0.20S 51.36 psi 164.32psi 0.3126 OK
Title Block Line 1 Project Title:
04/24/22 Page 111 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 20 APR 2022, 1:45PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level Side Footing in big office
Code References
Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Material Properties Soil Design Values
f'c : Concrete 28 day strength = 3.0 ksi Allowable Soil Bearing = 1.50 ksf
fy : Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = No
Ec : Concrete Elastic Modulus = 3,122.0 ksi Soil Passive Resistance (for Sliding) = 250.0 pcf
Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. = 0.30
Values Flexure = 0.90
Shear = 0.750 Increases based on footing Depth
Analysis Settings Footing base depth below soil surface = 1.50 ft
Min Steel % Bending Reinf. = Allow press. increase per foot of depth = 1.0 ksf
Min Allow % Temp Reinf. = 0.00180 when footing base is below = 1.0 ft
Min. Overturning Safety Factor = 1.0 : 1
Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension
Add Ftg Wt for Soil Pressure : Yes Allowable pressure increase per foot of depth
Use ftg wt for stability, moments & shears : Yes = ksf
when max. length or width is greater than
Add Pedestal Wt for Soil Pressure : No
= ft
Use Pedestal wt for stability, mom & shear : No
Dimensions
Width parallel to X-X Axis = 5.0 ft
Length parallel to Z-Z Axis = 5.0 ft
Footing Thickness = 14.0 in
Pedestal dimensions...
px : parallel to X-X Axis = in
pz : parallel to Z-Z Axis = in
=
Height in
Rebar Centerline to Edge of Concrete...
at Bottom of footing = 3.0 in
Reinforcing
Bars parallel to X-X Axis
Number of Bars = 7
Reinforcing Bar Size = # 5
Bars parallel to Z-Z Axis
Number of Bars = 7
Reinforcing Bar Size = # 5
Bandwidth Distribution Check (ACI 15.4.4.2)
Direction Requiring Closer Separation
n/a
# Bars required within zone n/a
# Bars required on each side of zone n/a
Applied Loads
D Lr L S W E H
P : Column Load = 13.0 25.0 k
OB : Overburden = ksf
M-xx = k-ft
M-zz = k-ft
V-x = k
V-z = k
Title Block Line 1 Project Title:
04/24/22 Page 112 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 20 APR 2022, 1:45PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level Side Footing in big office
DESIGN SUMMARY Design OK
Min. Ratio Item Applied Capacity Governing Load Combination
PASS 0.8630 Soil Bearing 1.726 ksf 2.0 ksf +D+L about Z-Z axis
PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning
PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding
PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding
PASS n/a Uplift 0.0 k 0.0 k No Uplift
PASS 0.3365 Z Flexure (+X) 6.950 k-ft/ft 20.652 k-ft/ft +1.20D+1.60L
PASS 0.3365 Z Flexure (-X) 6.950 k-ft/ft 20.652 k-ft/ft +1.20D+1.60L
PASS 0.3365 X Flexure (+Z) 6.950 k-ft/ft 20.652 k-ft/ft +1.20D+1.60L
PASS 0.3365 X Flexure (-Z) 6.950 k-ft/ft 20.652 k-ft/ft +1.20D+1.60L
PASS 0.3281 1-way Shear (+X) 26.958 psi 82.158 psi +1.20D+1.60L
PASS 0.3281 1-way Shear (-X) 26.958 psi 82.158 psi +1.20D+1.60L
PASS 0.3281 1-way Shear (+Z) 26.958 psi 82.158 psi +1.20D+1.60L
PASS 0.3281 1-way Shear (-Z) 26.958 psi 82.158 psi +1.20D+1.60L
PASS 0.6765 2-way Punching 111.154 psi 164.317 psi +1.20D+1.60L
Detailed Results
Soil Bearing
Rotation Axis & Xecc Zecc Actual Soil Bearing Stress @ Location Actual / Allow
Load Combination... Gross Allowable (in) Bottom, -Z Top, +Z Left, -X Right, +X Ratio
X-X, D Only 2.0 n/a 0.0 0.7258 0.7258 n/a n/a 0.363
X-X, +D+L 2.0 n/a 0.0 1.726 1.726 n/a n/a 0.863
X-X, +D+0.750L 2.0 n/a 0.0 1.476 1.476 n/a n/a 0.738
X-X, +0.60D 2.0 n/a 0.0 0.4355 0.4355 n/a n/a 0.218
Z-Z, D Only 2.0 0.0 n/a n/a n/a 0.7258 0.7258 0.363
Z-Z, +D+L 2.0 0.0 n/a n/a n/a 1.726 1.726 0.863
Z-Z, +D+0.750L 2.0 0.0 n/a n/a n/a 1.476 1.476 0.738
Z-Z, +0.60D 2.0 0.0 n/a n/a n/a 0.4355 0.4355 0.218
Overturning Stability
Rotation Axis &
Load Combination... Overturning Moment Resisting Moment Stability Ratio Status
Footing Has NO Overturning
All units k
Sliding Stability
Force Application Axis
Load Combination... Sliding Force Resisting Force Stability Ratio Status
Footing Has NO Sliding
Footing Flexure
Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status
k-ft Surface in^2 in^2 in^2 k-ft
X-X, +1.40D 2.275 +Z Bottom 0.3024 Min Temp % 0.4340 20.652 OK
X-X, +1.40D 2.275 -Z Bottom 0.3024 Min Temp % 0.4340 20.652 OK
X-X, +1.20D+1.60L 6.950 +Z Bottom 0.3024 Min Temp % 0.4340 20.652 OK
X-X, +1.20D+1.60L 6.950 -Z Bottom 0.3024 Min Temp % 0.4340 20.652 OK
X-X, +1.20D+L 5.075 +Z Bottom 0.3024 Min Temp % 0.4340 20.652 OK
X-X, +1.20D+L 5.075 -Z Bottom 0.3024 Min Temp % 0.4340 20.652 OK
X-X, +1.20D 1.950 +Z Bottom 0.3024 Min Temp % 0.4340 20.652 OK
X-X, +1.20D 1.950 -Z Bottom 0.3024 Min Temp % 0.4340 20.652 OK
X-X, +0.90D 1.463 +Z Bottom 0.3024 Min Temp % 0.4340 20.652 OK
X-X, +0.90D 1.463 -Z Bottom 0.3024 Min Temp % 0.4340 20.652 OK
Z-Z, +1.40D 2.275 -X Bottom 0.3024 Min Temp % 0.4340 20.652 OK
Z-Z, +1.40D 2.275 +X Bottom 0.3024 Min Temp % 0.4340 20.652 OK
Z-Z, +1.20D+1.60L 6.950 -X Bottom 0.3024 Min Temp % 0.4340 20.652 OK
Z-Z, +1.20D+1.60L 6.950 +X Bottom 0.3024 Min Temp % 0.4340 20.652 OK
Z-Z, +1.20D+L 5.075 -X Bottom 0.3024 Min Temp % 0.4340 20.652 OK
Z-Z, +1.20D+L 5.075 +X Bottom 0.3024 Min Temp % 0.4340 20.652 OK
Title Block Line 1 Project Title:
04/24/22 Page 113 of 113
You can change this area Engineer:
using the "Settings" menu item Project ID:
Project Descr:
and then using the "Printing &
Title Block" selection.
Title Block Line 6 Printed: 20 APR 2022, 1:45PM
File: Paisley Loft Calcs.ec6
General Footing Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
Lic. # : KW-06004654 BRADLEY ENGINEERING
DESCRIPTION: F Level Side Footing in big office
Footing Flexure
Flexure Axis & Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status
k-ft Surface in^2 in^2 in^2 k-ft
Z-Z, +1.20D 1.950 -X Bottom 0.3024 Min Temp % 0.4340 20.652 OK
Z-Z, +1.20D 1.950 +X Bottom 0.3024 Min Temp % 0.4340 20.652 OK
Z-Z, +0.90D 1.463 -X Bottom 0.3024 Min Temp % 0.4340 20.652 OK
Z-Z, +0.90D 1.463 +X Bottom 0.3024 Min Temp % 0.4340 20.652 OK
One Way Shear
Load Combination... Vu @ -X Vu @ +X Vu @ -Z Vu @ +Z Vu:Max Phi Vn Vu / Phi*Vn Status
+1.40D 8.82psi 8.82psi 8.82 psi 8.82 psi 8.82psi 82.16 psi 0.11 OK
+1.20D+1.60L 26.96psi 26.96psi 26.96 psi 26.96 psi 26.96psi 82.16 psi 0.33 OK
+1.20D+L 19.69psi 19.69psi 19.69 psi 19.69 psi 19.69psi 82.16 psi 0.24 OK
+1.20D 7.56psi 7.56psi 7.56 psi 7.56 psi 7.56psi 82.16 psi 0.09 OK
+0.90D 5.67psi 5.67psi 5.67 psi 5.67 psi 5.67psi 82.16 psi 0.07 OK
Two-Way "Punching" Shear All units k
Load Combination... Vu Phi*Vn Vu / Phi*Vn Status
+1.40D 36.39 psi 164.32psi 0.2214 OK
+1.20D+1.60L 111.15 psi 164.32psi 0.6765 OK
+1.20D+L 81.17 psi 164.32psi 0.494 OK
+1.20D 31.19 psi 164.32psi 0.1898 OK
+0.90D 23.39 psi 164.32psi 0.1423 OK
1/15/2020
04/24/2022
164'-2"
29'-8"
9'-7" 25'-8"
10' 26'-3" 6'
3' 7'-2" 46'-4"
HSS5X5X1
" COLUMN
2
1 ON 16"X8"X1
HSS5X5X 2" COLUMN 1 PLATE ATTACHED
STEM4" BASE 1
1
ON 16"X8"X1 " BASE
HDU4 HOLD DOWN
HDU4 HOLD DOWN HDU4 HOLD DOWN
HDU4 HOLD DOWN
HDU4 HOLD DOWN
PLATE ATTACHED STEM2 S2 WALL PER
DETAIL '5' S2 S2
S2
PER DETAIL '31' S8
PER DETAIL '31' S8 PER DETAIL '31' S8
PER DETAIL '31' S8
PER DETAIL '31' S8
HDU4 HOLD DOWN
WALL PER DETAIL '5' S2
PER DETAIL '31' S8
1'-6"
1'-6"
1'-6" 1'-6"
WIDEN FOOTING
6'X6'X16" FOOTING W/ 5'X5'X10"W/
(7) #5 3
(10) #5 BARS EACH WAY BARS EACH WAY
S2
2
HDU4 HOLD DOWN
S2
PER DETAIL '31' S8
3
S2
17'-10"
2
1
S2
S2
HSS5X5X1 " ON 12"X12"X1 "
HSS5X5X1 " ON 12"X12"X1 "
HDU4 HOLD DOWN
BASE PLATE ATTACHED TO4 2
BASE PLATE ATTACHED TO4 2 21'-6"
PER DETAIL '31'
S8
FOOTING PER DETAIL '4' S2
FOOTING PER DETAIL '4' S2
5'X5'X12" FOOTING W/
WIDEN FOOTING
(7) #5 BARS EACH
5'X5'X10"W/ (7) #5
WIDEN FOOTING
WAY SEE DETAIL '4' S2
BARS EACH WAY 4'X4'X10" FOOTING W/
28'-6" 5'X5'X10"W/
(7) #5 9'-5"
HSS5X5X1 " ON 12"X12"X1 "
(5) #5 BARS EACH
BARS EACH
WAY 4 2
BASE PLATE ATTACHED TO
HSS5X5X1 " COLUMN WAY SEE DETAIL '4' S2
5'X5'X14" FOOTING W/ 5'X5'X14"
FOOTING W/
4
FOOTING PER DETAIL '4' S2
ON 16"X8"X12" BASE 5'X5'X12" FOOTING W/
(7) #5 BARS EACH (7)
#5 BARS EACH
8'
30'
HSS5X5X1
PLATE ATTACHED STEM (7) #5 BARS EACH
WAY SEE DETAIL '4' S2 WAY SEE DETAIL
'4' S2
4" COLUMN
HSS5X5X1 " ON 12"X12"X1 "
ON 16"X8"X1 " BASE
WALL PER DETAIL '5' S2 2 WAY SEE DETAIL '4' S2 4 2
PLATE ATTACHED STEM2
" BASE
S2 BASE PLATE ATTACHED TO
2
FOOTING PER DETAIL '4' S2
WALL PER DETAIL '5' S2
" COLUMN1
4'X4'X10" FOOTING W/
HDU4 HOLD DOWNPER DETAIL '31' S8
4
(5) #5 BARS EACH WAY
HDU4 HOLD DOWN ELEVATOR PIT 8'-4" 1
PER DETAIL '31' S81:12 SLOPE DN
2
3'X3'X10" FOOTING
S2
ON 16"X8"X W/ (4) #4 BARS
HSS5X5X
6
EACH WAY
3
PLATE ATTACHED STEMWALL PER DETAIL '5' S2
1
1
S2
S2
HSS5X5X 4" ON
12"X12"X 2"
BASE PLATE ATTACHED
TO
FOOTING PER DETAIL
'4' S2
7
SLAB ON GRADE: 4" CONCRETE SLAB
3
16'-8" S2
OVER 6 MIL POLY VAPOR BARRIER,
HSS6X6X5 " ON 14"X14"X5 "
S2
OVER 4" COMPACTED GRANULAR FILL, OVER
BASE PLATE ATTACHED TO8 8
2
COMPACTED NATIVE SOILS OR STRUCTURAL FILL
FOOTING PER DETAIL '6' S2
3'X3'X10" FOOTING S2
4'X4'X10" FOOTING W/
13' 56'
58' 1'
W/ (4) #4 BARS
(5) #5 BARS EACH WAY
6'X6'X14" FOOTING W/
EACH WAY
(8) #5 BARS EACH
WAY SEE DETAIL '4' S2
6" HDU4 HOLD DOWN
3'-6"
HDU4 HOLD DOWN
3'
PER DETAIL '31' S8 HDU4 HOLD DOWN PER
PER DETAIL '31' S8
DETAIL '31' S8
8'X8'X18" FOOTING W/
6.3% SLOPE DN 1
(12) #5 BARS EACH
5'X5'X14"
FOOTING W/
S2
WAY SEE DETAIL '6' S2 HSS5X5X1 " COLUMN
HDU4 HOLD HDU4 HOLD DOWN HDU4 HOLD DOWN
(7)
#5 BARS EACH
2
DOWN PER
2 WAY SEE DETAIL
'4' S2
ON 16"X8"X1 " BASE
PER DETAIL '31' S8 1 PER DETAIL '31' S8
2
DETAIL '31' S8 1
S2
HDU4 HOLD DOWNPER DETAIL '31' S8
PLATE ATTACHED STEM
5'-62" S2
WALL PER DETAIL '5' S2
41'-10"
8' 36'-8"
HSS6X6X5 " ON 14"X14"X5 " HSS6X6X5 " ON 14"X14"X5 "
WIDEN FOOTING
8 8 8 8
BASE PLATE ATTACHED TO BASE PLATE ATTACHED TO
5'X5'X10"W/ (7) #5
WIDEN FOOTING
5 5
FOOTING PER DETAIL '6' S2 FOOTING PER DETAIL '6' S2
BARS EACH WAY
HSS5X5X14" ON 12"X12"X12"
HSS6X6X 8" ON 14"X14"X 8" 6
5'X5'X10"W/ (7) #5
BASE PLATE ATTACHED TO
HSS5X5X1 " COLUMN
BASE PLATE ATTACHED TO
S2
2
FOOTING PER DETAIL '4' S2
BARS EACH WAY
FOOTING PER DETAIL '6' S2
ON 16"X8"X12" BASE
PLATE ATTACHED STEM 5'X5'X14" FOOTING W/ HSS5X5X1 " ON 12"X12"X1 "
4 2
28'-6"
24'-6"
WALL PER DETAIL '5' S2 (7) #5 BARS EACH BASE PLATE ATTACHED TO
7'X7'X18" FOOTING W/ 7'X7'X18" FOOTING W/
7'X7'X18" FOOTING W/
WAY SEE DETAIL '4' S2 FOOTING PER DETAIL '4' S2
(10) #5 BARS EACH (10) #5 BARS EACH
(10) #5 BARS EACH
21'-6"
WAY SEE DETAIL '6' S2 WAY SEE DETAIL '6' S2
WAY SEE DETAIL '6' S2
23'-6"
1
1
S2
15'-5 "
2
1
S2
HSS5X5X1 " COLUMN
2
ON 16"X8"X1 " BASE
2
PLATE ATTACHED STEM
WALL PER DETAIL '5' S2
HSS5X5X12" COLUMN
HDU4 HOLD DOWNPER DETAIL '31' S8
HSS6X6X5 " ON 14"X14"X5 "
HSS6X6X5 " ON 14"X14"X5 " HSS6X6X5 " ON 14"X14"X5 "
8 8
8 8 8 8
ON 16"X8"X1 " BASE
WIDEN FOOTING
BASE PLATE ATTACHED TO
BASE PLATE ATTACHED TO BASE PLATE ATTACHED TO
PLATE ATTACHED STEM2
5'X5'X10"W/ (7) #5
FOOTING PER DETAIL '6' S2
FOOTING PER DETAIL '6' S2 FOOTING PER DETAIL '6' S2
WALL PER DETAIL '5' S2
BARS EACH WAY
6
S2
6
HDU4 HOLD DOWN
S2
HDU4 HOLD DOWN
PER DETAIL '31' S8
WIDEN FOOTING HSS5"X5"X12" 1
PER DETAIL '31' S8
HDU4
HOLD DOWN
1
5'X5'X10"W/ (7) #5 COLUMN S2
HSS5X5X 2" COLUMN PER
DETAIL '31' S8 7'X7'X18" FOOTING W/ 7'X7'X18" FOOTING W/
7'X7'X18" FOOTING W/
BARS EACH WAY
ON 16"X8"X1 " BASE 1
2
(10) #5 BARS EACH (10) #5 BARS EACH
(10) #5 BARS EACH
6'X6'X16" FOOTING W/ PLATE ATTACHED STEM S2
WAY SEE DETAIL '6' S2 WAY SEE DETAIL '6' S2
1' WAY SEE DETAIL '6' S2 1'
WALL PER DETAIL '5' S2
(8) #5 BARS EACH WAY
21'-8"
17' 24'
24' 25'
9'-2" 40'-4"
164'-2"
FOUNDATION
PLAN
SCALE: 3/16"
= 1' - 0"
FOUNDATION
DIMENSIONS: REFER TO THE ARCH DRAWINGS PROVIDED BY GLENN
WELLS ARCHITECT FOR FOUNDATION DIMENSIONS. THE DIMENSIONS ON STRUCTURAL
DRAWINGS
S1 ARE FOR ANALYSIS AND REFERENCE PURPOSES ONLY. BUILDER IS
RESPONSIBLE
FOR VERIFYING ALL DIMENSIONS AND INFORMATION WITH THE OWNER
PRIOR
TO CONSTRUCTION. OWNER AND/OR CONTRACTOR TO NOTIFY THE ENGINEER
DATE VER.
OF
ANY ERRORS OR OMISSIONS. THE ENGINEER OF RECORD IS NOT RESPONSIBLE FOR STRUCTURAL
DRAWINGS & DETAILS BRADLEY ENGINEERING
Engineering 4/24/2022 1
VERSION DATE REVISIONS
ACCURACY OF DIMENSIONS.
WWW.BRADLEYENGINEERINGINC.COM
ENGINEERED BY
1 4/24/2022 ORIGINAL PLANS
DAVID BRADLEY, P.E.
L. SCHWEIGERT
11
PAISLEY
LOFTS 811 YEW STREET // BELLINGHAM, WA 98229
Bradley CHECKED BY
(360) 752-5795
D. BRADLEY
of
105
E. DIVISON STREET DAVID@BRADLEYENGINEERINGINC.COM
APPROVED BY
D. BRADLEY
ARLINGTON,
WA FOR QUESTIONS & CHANGES PERTAINING TO THIS
PROJECT, CALL ATLUKE
(360) 510-9514 SCALE SIZE
S1
DRAWING TO BE PRINTED ON 24"X36" IN ORDER TO BE SCALE
OR EMAIL luke@bradleyengineeringinc.com
AS NOTED
D
2X6 STUDS @ 16" O.C.
1/15/2020
SHEATHING AND NAILING
5/8" DIAMETER X 10" LONG ANCHOR
PER SHEAR WALL PLANS
BOLTS @ 48" O.C. WITH 7" MINIMUM
EMBEDMENT INTO STEM WALL
1" MIN AIR GAP
(2) #4 CONTINUOUS REBAR WITHIN BRICK WALL TIE
3" FROM TOP OF STEM WALL AS REQUIRED
SHEATHING PER PLAN
04/24/2022
2X6 STUDS @ 16" O.C.
4" CONCRETE SLAB OVER 6
5/8" DIAMETER X 10" LONG GALV. 5/8" DIAMETER X 10"
MIL VAPOR BARRIER OVER FLASHING ON TOP OF BASE
ANCHOR BOLTS @ 48" O.C. (OK TO LONG ANCHOR BOLTS (2) #4 CONT. AT TOP
RIGID FOAM INSULATION COURSE WEEP HOLES @ 48" O.C.
5 @ 48" O.C. WITH 7" OF STEM WALL
USE SIMPSON 8" X10" TITEN SCREW MINIMUM EMBEDMENT
5 1
BRICK OR CMU DOWN
ANCHOR BOLTS OR EQUIVALENT) 4" CONC. SLAB
(4) 8"X8" TITEN HD SCREWS OR (4) HSS5"X5"X 4" STEEL COLUMN
2X STUD WALL
INTO STEM WALL
5/8" THREADED ROD EPOXIED WITH 12"
TO FOOTING, FILL
TYP. AT BEARING AND SHEAR WALLS
12"X12"X1 11"
BEARING
/
SIMPSON SET-3G OR EQUIVALENT, 2" BASE PLATE. WELD 2
BEHIND W/ MORTAR
WITH MINIMUM 8" EMBEDMENT HSS TO PLATE W/ 14" CONT. 1
SHEAR WALL
4" CONCRETE SLAB 12" VERIFY
12"
FILLET WELD ON ALL SIDES
PER PLAN
WITH ARCH.
4" CONC. SLAB
4" COMPACTED
4" CONC. SLAB PLANS
#5 REBAR EACH WAY. BASE PLATE SHOWN ON FOOTING
4" DIAMETER
GRANULAR FILL #4 VERTICAL BARS 24" O.C.
NUMBER OF BARS STRUCTURALLY OKAY TO PLACE
#4 VERTICAL REBAR AT 12" O.C.,
ALTERNATE HOOK DIRECTION TIGHT LINE
ALTERNATE HOOK
REQUIRED PER PLAN BASE PLATE ON SLAB (TYP.) 12" 9"
DIRECTION IN FOOTING
3
18" MIN
Ø "
#4 HORIZONTAL REBAR AT 12" O.C. 12"
#4 HORIZONTAL BARS 18"
4
4" DIAMETER
O.C. ALTERNATE HOOK
1
PERFORATED
DIRECTION IN FOOTING
DEPTH 3" CONC. COVER 12"
8" DRAIN PIPE
PER FROM BOTTOM
8"
1" THICK A36
24" (3) #5 REBAR CONTINUOUS,
PLAN OF FOOTING 2
3" FROM BASE OF FOOTING
STEEL PLATE
#4 TIE BARS 24" O.C. (3) #4 CONTINUOUS REBAR
8" 8" 8" AT BASE OF FOOTING
FOOTINGS TO BEAR ON COMPACTED (2) #4 CONT. 5" 8" 5"
WIDTH PER PLAN BASE PLATE
NATIVE SOILS OR STRUCTURAL FILL (TYP.) REBAR 18"
1 1/2" = 1'- 0"
1 TYPICAL FOUNDATION DETAIL 2 THICKENED FOOTING
DETAIL 3 FOUNDATION DETAIL
4 INTERIOR FOOTING & BASE PLATE DETAIL
SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0"
BEARING/SHEAR WALL SCALE: 3/4" = 1'-0"
SCALE: 3/4" = 1'-0"
HSS 6"X6"X5" STEEL COLUMN SIMPSON PAB7-24 OR (4) 7" GALV.
8 8
14"
F1554 THREADED ROD WITH 18"
2"
14" X14" X 5" BASE PLATE WELDED MIN. EMBEDMENT INTO CONCRETE.
8
5X5 HSS COLUMN PER PLAN SET
TO HSS W/ 5" CONT. FILLET WELD WASHER AND NUT ASSEMBLY
2"
8
#4 V-BARS @ 12" O.C.
IN WALL. ATTACH WOOD STUD
SIMILAR TO PAB ANCHOR BLOT
LEVELING NUT ASSEMBLY (OPTIONAL)
TO HSS PER TYPICAL DETAIL
(2) 3/4" GALV. THREADED ROD
(3) #4 REBAR HOOPS SPACED
GROUT WITH Fc' = 8,000 PSI,
#4 T-BARS @ 12" O.C.
EPOXIED WITH SIMPSON SET-3G 16"X8"X5/8" STEEL BASE
3" O.C. IN TOP 12" OF PLINTH
INSTALLED AFTER LEVELING NUT 14"
10"
OR EQUIVALENT 12" MIN. PLATE USE MID-WALL OR
AND 12" O.C. THROUGHOUT
EMBEDMENT DEPTH. SEE BASE END WALL PLATE AS 8" 8"
IS ADJUSTED IN FINAL POSITION Ø15"
5" 3" 5"
3" 16
PLATE FOR BOLT SPACING REQUIRED PER PLAN
1
1
V-BARS @ WALL CL
1 "
1 " (8) #5 VERTICAL HOOKS
Ø13" 2 Ø13"
2
16 16
CONC. SLAB 1' HOOK INTO FOOTING
WELD HSS TO BASE 1
2"
1 5 " THICK A36 2" 7" 5 " THICK A36
PLATE W/ 4" CONT. FILLET 8 8
WELD ON ALL SIDES STEEL PLATE STEEL PLATE
10"
5/8" THICK A36 REBAR LAP =
1
STEEL PLATE 48*BAR DIAMETER
TYPICAL 8" CONCRETE 14" 11" 14"
2" 11" #5 REBAR EACH WAY.
STEM WALL SEE
NUMBER OF BARS BASE
PLATE
DETAIL '1' OR '3' S2
REQUIRED PER PLAN
7"
DEPTH
1 1/2" = 1'- 0" MAIN SLAB 8"
PER 3" CONC. COVER
BARS STOP 2"
4"
1
1 PLAN FROM BOTTOM
FROM EDGE
1 "
1 "
2
2 OF FOOTING
OF SLUMP PIT
BASE PLATE (MID-WALL) BASE PLATE (END WALL)
18"
1 1/2" = 1'- 0" 1 1/2" = 1'- 0"
WIDTH PER PLAN
12"
3"
HSS6X6X5 " COLUMN AND FOOTING
5 HSS5X5 COLUMN TO STEM WALL
6 8
10"
SCALE: 3/4" = 1'-0"
SCALE: 3/4" = 1'-0"
#5 BARS @ 8" O.C. EACH WAY
10" 8"
(2) #4 L BARS AT EACH SIDE OF PIT
1ST POUR 2ND POUR
SLAB COMPOSED OF
SLUMP PIT AS REQUIRED
TWO SEPARATE POURS
LINE OF SLAB BEYOND PIT 6" THICK CONCRETE BASE
ANCHOR BOLTS
AND WALL FOR PIT.
1. Ø5/8"X10" LONG @ 48" O.C. MAX.
2. MIN. 2 PER SILL. 0.145 DIA. PAF
7 ELEVATOR PIT FOUNDATION
1-3/4" 3. WITHIN 12" FROM SILL END. @ 12" O.C.
MIN. EMBED PER MFR.
SCALE: 3/4" = 1' - 0"
4" COMPACTED
RECOMMENDATIONS
UNDISTURBED NATIVE SOIL OR
5" DIA. WELDED
COMPACTED FILL MATERIAL COLD JOINT GRANULAR FILL
8 THREADED
STUD @ 48" O.C. STEEL COLUMN
PER PLAN
1" SAW CUT OR USE GROOVER
8
TOOL TO CREATE CONCRETE JOINT
SIMPSON TB
SCREWS @ 12" O.C. 2X STUD
SLAB TO BE POURED MONOLITHICALLY.
(FOR STEEL LESS
D (1 )D SAW CUT METHOD TO BE PERFORMED
4
THAN 5" THICK)
4 TO 12 HOURS AFTER POUR.
REQUIRED AT 16
ALL LOCATIONS
NOTE: THREE OPTIONS FOR CONNECTING WALL
STUD TO STEEL ARE PROVIDED ABOVE. ANY
OF THE THREE CONNECTIONS CAN BE USED
30 TYPICAL WALL STUD
UNDISTURBED NATIVE SOIL OR SAW CUT OR 4" COMPACTED
COMPACTED FILL MATERIAL GRANULAR FILL
GROOVE JOINT
ANCHOR BOLTS TO SILL PLATE TO STEEL COLUMN
CONCRETE SLAB NOTES: SUB-GRADE PREPARATION:
SCALE: 1" = 1' - 0"
·EITHER OF THE ABOVE TWO JOINT OPTIONS ARE ADEQUATE SLAB TO BEAR ON UNDISTURBED NATIVE SOILS AND/OR STRUCTURAL
·SPACE JOINTS @ 12' O.C. MAX. EACH WAY FILL (SEE STANDARD STRUCTURAL SPECIFICATIONS FOR MORE
·TYPICAL SLAB 4" CONCRETE SLAB OVER 6 MIL POLY VAPOR INFORMATION) COMPACTED IN LIFTS OF ONE FOOT OR LESS TO 95%
BARRIER OVER 4" COMPACTED GRANULAR FILL OF A MODIFIED PROCTOR PER ASTM D1557. SOILS SHALL BE FIRM AND
UNYIELDING. ALL ORGANIC AND DELETERIOUS MATERIAL BENEATH
THE SLABS TO BE REMOVED AND REPLACED WITH 4" MINIMUM
COMPACTED GRANULAR FILL TO 95% RELATIVE COMPACTION.
TYPICAL CONCRETE SLAB JOINTS
SCALE: 1" = 1'-0"
DATE
VER.
STRUCTURAL DRAWINGS & DETAILS
BRADLEY ENGINEERING Engineering 4/24/2022
1 VERSION DATE REVISIONS
WWW.BRADLEYENGINEERINGINC.COM
ENGINEERED
BY
1 4/24/2022 ORIGINAL PLANS
DAVID BRADLEY, P.E. L.
SCHWEIGERT 11
PAISLEY LOFTS
811 YEW STREET // BELLINGHAM, WA 98229 Bradley CHECKED
BY
(360) 752-5795 D.
BRADLEY of
105 E. DIVISON STREET
DAVID@BRADLEYENGINEERINGINC.COM
APPROVED
BY
D.
BRADLEY
ARLINGTON, WA
FOR QUESTIONS & CHANGES PERTAINING TO THIS
PROJECT, CALL ATLUKE (360) 510-9514 SCALE
SIZE S2
DRAWING
TO BE PRINTED ON 24"X36" IN ORDER TO BE SCALE
OR EMAIL luke@bradleyengineeringinc.com AS
NOTED D
1/15/2020
04/24/2022
4 FT LONG 3 " PLY CANTILEVER
4 FT LONG 3 " PLY CANTILEVER
4 FT LONG 3 " PLY CANTILEVER
UPSIDE DOWN 4
4
4
HGUS5.50/12 REINFORCEMENT ATTACHED TO
REINFORCEMENT ATTACHED TO
REINFORCEMENT ATTACHED TO
HANGER EACH SIDE OF I-JOIST AT 2 FT
EACH SIDE OF I-JOIST AT 2 FT
EACH SIDE OF I-JOIST AT 2 FT
CANTILEVER SEE DETAIL '12' S4 (TYP.)
CANTILEVER SEE DETAIL '12' S4 (TYP.)
CANTILEVER SEE DETAIL '12' S4 (TYP.) (2) TRIMMER
~15 FT LONG 31 " X 117 " LVL HELD UP
2 8
(1) KING STUD
(2) TRIMMER
(2) TRIMMER (2) TRIMMER (2) KING STUD (2) TRIMMER
(2) TRIMMER
134" X 1178" LVL RIM
(1) KING STUD (2) KING STUD (2) KING STUD
(2) KING STUD
W14X26 HDR
SCREWED TO END HU11 HANGER
OF 31 " X 117 " LVL
2 8
W/ (6) 4" #10 13
1 1
312"X9" GLB OR 6X10 DF #1 HDR 31 "X9" GLB OR 6X10 DF #1 HDR 312"X9" GLB OR 6X10
DF #1 HDR
SCREWS 4"X11
5 2" X 13 2" GLB HDR
2
BLOCK BETWEEN JOSITS AT BEAR ON
6X6 DF
HSS5"X5"X1 "
4
7 CANTILVER ATTACH BLOCKING TO 1 POST
IN WALL
1 HSS5"X5"X1 " CONNECT TO 1
(3) TRIMMER
8" LVL'S 16" O.C.
(2) TRIMMER (2) TRIMMER
5 2" X 12" GLB HDR 4 5 2" X 12" GLB HDR
1 7
" LVLHSS5"X5"X1 " WALL PLATE W/ A35 16" O.C. (TYP.)
(2) KING STUDS (2) KING STUDS
CONNECT TO HEADER PER
1 2" X 11 8" LVL OR LSL
(2) KING
8 2
IUS LEDGER TO WALL
7 COLUMN
312" X 1178" GLB TOP OF BEAM
(2) TRIMMER HEADER PER DETAIL '29' S4
STUDS
DETAIL '29' S4
HANGERS STUDS W/ (3) 1 " X 41 "
FLUSH W/ TOP OF LANDING JOISTS
(2) KING STUDS
4 2
" X 11
(TYP.) SDS SCREWS 16" O.C.
4
HU612 15 " X 3" LAG SCREWS
HU11 HANGER OF BEAM TO POST W/12
LANDING JOISTS:
31 " X 117 " GLB
HANGER
117 "
TJI 210 2 8
SCREW BOTTOM FLANG(2)
JOISTS @ 16"
O.C.8
IUS HANGERS WALL ON TOP OF
(TYP.) BEAM UP TO SECOND
1 8
1 7
HSS5"X5"X 4"
5 2" X 11 8" GLB SET 8 FT
31 " X 117 " GLB FLOOR JOISTS
BACK FROM NORTH WALL 2X PLATE ON STEEL BEAM
LANDING JOISTS: 2 8
DOWN CONNECTION S4 BA2.37/11.88
ATTACHED W/ 5 " THREADED
TO BEAM PER TOP
FLANGE
8
117 " TJI 210
8
HANGER
(TYP.) " X 3" LAG SCREWS
STUDS WELDED 48" O.C.
JOISTS @ 16" O.C.
DETAIL '14' S4 W16X50 STEEL BEAM
W16X50 STEEL BEAM 12
W12X40
STEEL BEAM
" X 15" GLB HDR2
DOWN FRAME STAIRS W/ 2X12 WHERE BEARING
WALL SITS
DOWN
15
11
24'-1 "
W18X86
STRINGERS @ 12" O.C. OVER TOP
OF BEAM ATTACH 8
16 SCREW BOTTOM FLANG OFBEAM TO POST OR HEADERW/ (2)
WHERE BEARING WALL SITS STEEL BEAM STEEL
BEAM
HSS5"X5"X14"
WALL PER
DETAIL '10' S4 (TYP.) S4
STEEL BEAM OVER TOP OF BEAM ATTACH CONNECT. PER CANTILEVERS
W12X53 STEEL BEAM
CONNECTION
WALL PER DETAIL '10' S4 (TYP.) DETAIL '11' S4
W12X53 STEEL BEAM
31 " X 117 " GLB
TO BEAM PER
OVER ~1'
TO CATCH
W12X53 STEEL BEAM W12X53 STEEL BEAM
2 8
POINT
LOAD FROM
DETAIL '14' S4
11 BEAM ABOVE
(3) TRIMMER
S4 ~26'8" LONG W12X53 STEEL BEAM 1
1
16 HSS5"X5"X1
" BLOCK BETWEEN
(2) KING
HELD UP IN LINE W/ FLOOR JOISTS HSS5"X5"X 2"
DOWN HSS5"X5"X 4"
HSS5"X5"X14" S4
4
CONNECTION
UP CONNECTION BA2.37/11.88
CONNECTION CONNECTION
UP JOISTS BELOW OFFSET
STUDS
TO BEAM PER
TO BEAM PER TOP FLANGE
TO BEAM PER WEB STIFFENERS REQUIRED TO BEAM
PER BLOCK BETWEEN BEARING WALL (TYP.)
BLOCK BETWEEN JOISTS OVER DETAIL '13' S4
BEARING WALL 1 7 DETAIL '13' S4 HANGER (TYP.)
DETAIL '14' S4 TO BE ATTACHED TO JOISTS HSS5"X5"X1 DETAIL
'13' S4 JOISTS BELOW OFFSET
BEAM ATTACH BLOCKING TO 2X
3 2" X 11 8" GLB
4"
OVER THIS BEARING WALL LINE CONNECTION
HSS5"X5"X1 " BEARING WALL (TYP.)
HSS5"X5"X14"
PLATE ON BEAM W/ A35 ANGLE,
TO BEAM PER
CONNECT TO4
CONNECT TO
SEE DETAIL '9' S4 (TYP.)
WHERE BEARING WALL SITS
WHERE BEARING WALL SITS
DETAIL '13' S4 4X10 DF HDR
HEADER PER OVER TOP OF BEAM ATTACH
HEADER PER
OVER TOP OF BEAM ATTACH GLB NOTCHED
INTO
BEARING WALL
DETAIL '29' S4
DETAIL '29' S4
STEEL
BEAM SIMILAR
BLOCK BETWEEN 4X10 DF HDR BEARING WALL
WALL PER DETAIL '10' S4 (TYP.)
WALL PER DETAIL '10' S4 (TYP.)
TO DETAIL
'16 S4 31 " X 117
" GLB HELD UP JOISTS BELOW OFFSET
2
8
BEARING WALL (TYP.)
W16X50 STEEL BEAM
W16X50 STEEL BEAM
4X10 DF HDR
11
W12X53 STEEL BEAM HELD UP 1
7 1 7 312" X 1178" GLB HELD UP BEARING WALL
51 " X 117 " 17 W14X26 HEADER
S4 5 2" X 11
8" GLB HELD UP 5 2" X 11 8" GLB HELD UP
2 8 HSS5"X5"X14"
IN LINE W/ FLOOR JOISTS
WEB STIFFENERS REQUIRED
GLB HELD UP
FLOOR SYSTEM
S4 HSS5"X5"X1 " CONNECTION
BA2.37/11.88
TO BE ATTACHED TO JOISTS
4
5
11 7" TJI 360 JOISTS @ 16" O.C. WITH
CONNECT TO TO BEAM PER
TOP FLANGE " LVL OR DOUBLE
HSS6"X6"X 8"
8
OVER THIS BEARING WALL LINE
HEADER PER DETAIL '14' S4
8
CONNECT TO BEAM
3/4" T&G SHEATHING GLUED AND
4X10 DF HDR DETAIL '29' S4
HANGER (TYP.) 7
PER DETAIL '15' S4
NAILED TO JOISTS & 11 " GYPCRETE.
2
4X10 DF HDR
" X 11
51 " X 12" GLB HDR
4
" GYPCRETE.
2
3
2
1 JOIST BELOW WALL ABOVE
1
15
W14X26 STEEL HEADER
S4
(3) TRIMMER (3) TRIMMER
4X10 DF HDR
4X10 DF HDR 31 "X9" GLB OR 6X10 DF #1 HDR
(2) KING STUDS (2) KING STUDS
2
FLOOR SYSTEM
" LVL RIM JOIST
1
8
HSS5"X5"X 4"
7
(2) TRIMMER (2) TRIMMER
CONNECT TO
7" TJI 560 JOISTS @ 16" O.C. WITH8
(2) KING STUDS (2) KING STUDS
8
BA2.37/11.88 HEADER PER
" X 11 3/4" T&G SHEATHING GLUED AND
HSS6"X6"X5 "
HSS6"X6"X5 " HSS6"X6"X5 "
TOP FLANGE
4 11 NAILED TO JOISTS & 1
8
8 BLOCKING AND ATTACHMENT OF JOIST 8
S4
DETAIL '29' S4
31 ALONG WEST ELEVATIONCANTILEVERED WALL (TYP.) WHERE BEARING WALL SITS
CONNECTION
CONNECTION CONNECTION
HANGER (TYP.)
OVER TOP OF BEAM ATTACH
TO BEAM PER
TO BEAM PER TO BEAM PER DETAIL '9' S4 (TYP.) TO BEAM PER
(3) TRIMMER
W16X50 STEEL BEAM
(2) KING
WALL PER DETAIL '10' S4 (TYP.)
W18X65 STEEL BEAM DETAIL '14' S4 W18X65 STEEL BEAM
DETAIL '14' S4 W18X65 STEEL BEAM DETAIL '14' S4 W18X65 STEEL BEAM
STUDS
11
W12X53 STEEL BEAM HELD UP
BEARING WALL HSS5"X5"X1
HSS5"X5"X1
S4 HSS5"X5"X1
"
HSS5"X5"X1 " 4"
4"
IN LINE W/ FLOOR JOISTS
2
ATTACH 2X8 NAILER TO BEAM
2 CONNECTION
CONNECTION
CONNECTION
5
CONNECTION
W/ 8" THREADED STUD 48" O.C.
TO BEAM PER
TO BEAM PER
TO BEAM
PER
TO BEAM PER
SEE DETAIL '9' S4 (TYP.)
DETAIL '13' S4
DETAIL '14' S4
DETAIL
'13' S4
DETAIL '13' S4
RIM JOIST OVER THIS
BLOCK FLOOR DIAPHRAGM IN
BEARING / SHEAR WALL
HATCHED REGION AND
ATTACHED TO TOP
ATTACH SHEATHING PER
PLATE W/ A35 16" O.C.
BLOCKED FLOOR DIAPHRAGM
" X 3" LAG SCREWS
2
DETAIL '34' ON THIS SHEET
" X 9" GLB HDR1
2
W18X86 STEEL BEAM
15 SCREW BOTTOM FLANGOF BEAM TO HDR W/ (2)
BLOCK BETWEEN JOISTS OVER
(2) TRIMMER
BEAM ATTACH BLOCKING TO 2X
(2) KING
BLOCK FLOOR DIAPHRAGM IN
PLATE ON BEAM W/ A35 ANGLE,
STUDS
HATCHED REGION AND
1 HSS6"X6"X5 "
HSS6"X6"X5 " HSS6"X6"X5 "
SEE DETAIL '9' S4 (TYP.) HSS5"X5"X
2" 8
8 8
ATTACH SHEATHING PER CONNECTION
CONNECTION CONNECTION
CONNECTION
BLOCKED FLOOR DIAPHRAGM TO BEAM
PER TO BEAM PER
TO BEAM PER TO BEAM PER
DETAIL '34' ON THIS SHEET RIM JOIST OVER THIS DETAIL
'13' S4 W18X65 STEEL BEAM DETAIL '14' S4 W18X65 STEEL BEAM
DETAIL '14' S4 W18X65 STEEL BEAM DETAIL '14' S4 W18X65 STEEL BEAM
312"X9" GLB OR 6X10 DF #1 HDR
312"X9" GLB OR 6X10 DF #1 HDR
BEARING / SHEAR WALL
ATTACHED TO TOP
PLATE W/ A35 16" O.C.
(2) TRIMMER (2)
TRIMMER (2) TRIMMER
(2) KING STUD (2)
KING STUD (2) KING STUD
3
3
HSS5"X5"X1 " 1 7
4 FT LONG 4" PLY CANTILEVER
4 FT LONG 4" PLY CANTILEVER
2 ~15 FT LONG 3 2" X 11 8" LVL RIM JOIST
4 FT LONG 3 " PLY CANTILEVER
HSS5"X5"X1 "
CONNECTION
4 REINFORCEMENT ATTACHED TO 9
REINFORCEMENT ATTACHED TO
9 2
TO BEAM PER
REINFORCEMENT ATTACHED TO EACH SIDE OF I-JOIST AT 2 FT
EACH SIDE OF I-JOIST AT 2 FT
CONNECTION
DETAIL '13' S4
EACH SIDE OF I-JOIST AT 2 FT CANTILEVER SEE DETAIL '12' S4 (TYP.) S4
CANTILEVER SEE DETAIL '12' S4 (TYP.)
S4 TO BEAM PER
CANTILEVER SEE DETAIL '12' S4 (TYP.)
DETAIL '13' S4
SECOND FLOOR
FRAMING PLAN
SCALE: 3/16"
= 1' - 0"
8D NAILS @ 12" O.C. IN THE FIELD
NOTES:
DIAPHRAGM 4'X8'
· INTERIOR LOAD BEARING AND EXTERIOR WALL HEADERS TO BE
BOUNDARY CONTINUOUS
3" CD/OSB PANEL
JOINT 4X10 DF #2 UNLESS NOTED OTHERWISE. IN LIEU OF EXTERIOR LOAD
4
BEARING HEADERS OKAY TO ATTACH JOISTS TO STRUCTURAL RIM
PER DETAIL '23' S6 (TYP. FOR OPENINGS 6 FT OR LESS)
· INTERIOR BEARING WALL
R 2X4 BLOCKING CUT AND
· BEARING FROM ABOVE
8D NAILS @4" O.C. AT
FITTED BETWEEN JOISTS
DIAPHRAGM BOUNDARY
AT PANEL EDGES. 10D
RING
AND SUPPORTED EDGES.
SHANK NAILS @ 6" O.C.
SEE
R SECTION R - R.
2X BLOCKING
Engineering DATE VER.
VERSION DATE REVISIONS
(OR LAID FLAT) STRUCTURAL
DRAWINGS & DETAILS BRADLEY ENGINEERING
4/24/2022 1
WWW.BRADLEYENGINEERINGINC.COM
ENGINEERED BY
1 4/24/2022 ORIGINAL PLANS
FLOOR JOISTS @ 16" O.C. (TYP.) SEC. R - R
DAVID BRADLEY, P.E.
L. SCHWEIGERT
11
PAISLEY
LOFTS 811 YEW STREET // BELLINGHAM, WA 98229
Bradley CHECKED BY
34 BLOCKED FLOOR DIAPHRAGM
(360) 752-5795
D. BRADLEY
of
105
E. DIVISON STREET DAVID@BRADLEYENGINEERINGINC.COM
APPROVED BY
SCALE: 1/4" = 1'-0"
D. BRADLEY
ARLINGTON,
WA FOR QUESTIONS & CHANGES PERTAINING TO THIS
PROJECT, CALL ATLUKE
(360) 510-9514 SCALE SIZE
S3
DRAWING TO BE PRINTED ON 24"X36" IN ORDER TO BE SCALE
OR EMAIL luke@bradleyengineeringinc.com
AS NOTED
D
1
1 "
4
1 1" GYPCRETE OVER
2 2X6 STUDS @ 16" O.C.
34" SHEATHING
WALL NOT SHOWN OVER BEAM. WHERE
1/15/2020
21"
1/4" THICK A36
117 " TJI 360
WALL SITS OVER BEAM ATTACH WALL PLATE 2
8
STEEL PLATE
JOISTS @ 16" O.C.
TO STEEL BEAM PER DETAIL '10' S4 (TYP.)
1
10" 2 "
2X6 STUDS 2
5
SHEATHING TO BLOCKING
1 1" GYPCRETE OVER 3 " SHEATHING
Ø "
CANTILEVER REINFORCEMENT
@ 16" O.C. 2 4
16
CONNECT SUBFLOOR TO BEAM WITH
W/ 8d NAILS 4" O.C.
21"
HANG JOISTS OFF TOP FLANGE WITH SIMPSON PDPAT-100 KP
REQUIRED WHERE NOTED ON
ATTACH SUB-FLOOR SHEATHING TO 2
SIMPSON ITS2.06/11.88 HANGERS FASTENED
PLANS. SEE DETAIL '12' S4 FOR
STEEL BEAM W/ SIMPSON PDPAT-100 KP
04/24/2022
POWDER-DRIVEN TOP-HAT PIN AT 6" O.C.
1 1 " SDS
TO TOP FLANGE WITH QTY (4) SIMPSON
REQUIREMENTS (TYP.)
4" 4 2 POWDER DRIVEN TOP-HAT PIN AT 6" O.C.
SCREW 16" O.C. 11" 2" 3" 6" 3"
2"
PDPAT-62 KP POWDER-DRIVEN TOP-HAT PIN 1-1/2" GYPCRETE (TYP.)
W12X53 STEEL BEAM HELD 4
BLOCKING TO 2X8 RIM TO TOP AND BOTTOM
INTO RIM JOIST 16"
UP BELOW BEARING WALL
PLATE W/ A35 (TYP.) FLANGE OF CANT. JOIST
3/4" SUBFLOOR, GLUED AND NAILED
1
134" X 1178" LVL END PLATE
W/ 3 2" #10 SCREW (TYP.)
WITH 8d AT 6" O.C. ALONG EDGES,
RIM JOIST
SIMPSON BA2.37/11.88
1 1/2" = 1'- 0"
12" O.C. IN THE FIELD
OR EQUIVALENT
BLOCK BWTWEEN JOISTS
8" diameter maximum hole for 117 " -
5
4'-0" length of 8
TOP FLANGE HANGER
8" THREADED STUD WELDED AT CANTILEVER (TYP.)
1
3 16" deep blocking panels; 6" diameter
11-7/8" TJI 210 @ 16" O.C. OR
TO STEEL BEAM W/ 4" CONT.
4" reinforcement 1
FILLET WELD. ATTACH 2X SCREW BOTTOM FLANGE OF
on both sides maximum for blocking panels 9 2"
EQUIVALENT 11-7/8" DEEP I-JOIST
PLATE W/ WASHER & NUT 1
16"X10"X14" STEEL PLATE WELDED TO
deep or shorter than 12" long.
WITH 2-1/16" FLANGE WIDTH MIN
I-JOIST TO 2X8 PLATE W/ (2) 2 4'
WEB OF STEEL BEAM W/ 3 " FILLET WELD
W-FLANGE BEAM PER PLAN
W18X65 STEEL BEAM #10 SCREWS ON EACH SIDE
16 BOLT STEEL BEAMS
Do not cut flanges.
EACH SIDE, SCREW STEEL PLATE TO RIM
TOGETHER W/ (4) 5 "
JOIST W/ (16) 1 " X 2" SDS SCREWS 8
4 A325 THRU BOLTS
11 1
OPTION 1 - SIMPSON ITS WITH POWDER ACTUATED FASTENERS
W18X86 STEEL BEAM
8" TJ® Rim Board or 1 4"
9 I-JOISTS BEARING ON STEEL BEAM
TimberStrand® LSL. Nail with
10d (0.131" x 3") nails, one each
SCALE: 3/4" = 1'-0"
at top and bottom flange. U.N.O
CONNECT SUBFLOOR TO BEAM WITH
AT CANTILEVER
SHOP OR FIELD WELD SIMSPON BA OR SIMPSON PDPAT-100 KP
11 STEEL BEAM DETAIL AT CANTILEVER
Attach reinforcement
HB HANGER TO TOP FLANGE OF STEEL POWDER-DRIVEN TOP-HAT PIN AT 6" O.C.
BEAM WITH 2" LONG FILLET WELD TO
2X6 BEARING OR
SCALE: 3/4" = 1'-0"
to joist flange with
1-1/2" GYPCRETE (TYP.)
5/8" DIA. THREADED STUD
BELOW BEARING WALL
8d (0.131" x 212") nails at 6"
EACH SIDE OF EACH TOP FLANGE
SHEAR WALL PER PLAN
2'-0"
3/4" SUBFLOOR, GLUED AND NAILED
@ 48" O.C. WELDED TO
Face grain on-center. When reinforcing
2X6 BOTTOM PLATE TOP OF STEEL BEAM WITH
maximum both sides, stagger nails.
SIMPSON BA2.37/11.88 OR SIMILAR WITH 8d AT 6" O.C. ALONG EDGES,
1/4" FILLET AROUND
horizontal
WELDABLE TOP FLANGE HANGER. 12" O.C. IN THE FIELD
2X6 P.T. PLATE
USE OSB OR PLY FILLER AS NEEDED
1-1/2" GYPCRETE (TYP.)
12 TYPICAL CANTILEVER
TO FILL JOIST HANGER SEAT 11-7/8" TJI 360 @ 16" O.C.
OR EQUIVALENT
3/4" SUBFLOOR, GLUED AND NAILED
SIMPSON JOIST HANGERS WITH 8d AT 6" O.C. ALONG EDGES,
REINFORCEMENT
W-FLANGE BEAM PER PLAN
PER DETAIL '8' S4 12" O.C. IN THE FIELD
SCALE: N.T.S.
11-7/8" I-JOISTS PER PLAN
OPTION 2 - SIMPSON BA HANGER WITH 2" FILLET WELDS
W-FLANGE BEAM PER PLAN
5"
1
2 "
2
8 I-JOISTS HUNG FROM W-FLANGE
10 STEEL BEAM HELD UP FLUSH WITH
WHERE JOISTS ARE HUNG FROM BEAM ATTACHED
HANGERS TO TOP FLANGE PER DETAIL '8' S4 11"
2
SCALE: 3/4" = 1'-0"
SCALE: 3/4" = 1'-0"
WHERE WALL PLATE SITS ON STEEL Ø13"
TYPICAL
BEARING/SHEAR WALL ABOVE
BEAM ATTACH PER DETAIL '10' S4 (TYP.) 16
10"
21" 5" 21" 11"
1 STANDARD COPING REQUIRED 6" 9"
2 2 2
2" TOP AND BOTTOM FLANGE
13
Ø "
16
11"
7"
BLOCK BETWEEN JOIST AT CANTILEVER 1
2
1 1 1"
5 " THICK A36 32"
1
12" 4" 12" 12
8
2" THICK A36
3 " SUB-FLOORING GLUED AND NAILED STEEL PLATE
(3) 3" DIA. GROUP A (A325)
4
4
11
" GYPCRETE
STEEL PLATE
Ø13"
2 TO BLOCKING W/ 10d NAILS 4" O.C.
BOLTS W/ STD HOLES
16
3"
51"
SHEAR PLATE DETAIL
5
2
WHERE JOISTS ARE HUNG FROM BEAM ATTACHED 8" THICK A36
HSS6"X6"X5 "
1 1/2" = 1'- 0"
WHERE WALL PLATE SITS
STEEL PLATE
8
WHERE JOISTS ARE HUNG ON STEEL BEAM ATTACH 7"
HANGERS TO TOP FLANGE PER DETAIL '8' S4
COLUMN WELD 21"
PER DETAIL '10' S4 (TYP.) 11" 4" 11" 11"
WHERE WALL PLATE SITS ON STEEL 1
SCREW BOTTOM FLANGE OF TO PLATE W/ 1 "
W12X53 STEEL 9"X5"X3" SHEAR PLATE WELDED
FROM BEAM ATTACHED 2 2 2
4 "
2
8
BEAM ATTACH PER DETAIL '10' S4 (TYP.) HSS COLUMN 2 BLOCKING
TO 2X I-JOIST TO 2X PLATE W/ (2) 2 1'
BEAM 1
HANGERS TO TOP
4 CONT. FILLET 1
TO W12X53" W/ 4" FILLET WELD
FLANGE PER DETAIL '8' S4 13
PER PLAN WELD PLATE W/ A35
(TYP.) #10 SCREWS ON EACH SIDE 52"
Ø "
18"
ON EACH SIDE
16
TO PLATE W/ 3 "
8
5 3"
CONT. FILLET 1
W-BEAM PER PLAN 8" THICK A36 BEAM
JOINT WHERE 42"
STEEL PLATE OCCURS
TO BE AT MID
GUSSET TO 1
16 SHEAR CONNECTION DETAIL
3 "
12"
POINT OF COLUMN 1
PLATE & HSS 2
GUSSET TO 41"
16"X8"X 2" SPLICE PLATE GUSSET TO 2X12 PLATE
RIPPED TO 58" THREADED STUD 48" O.C. 1
SCALE: 1" = 1'-0"
(4) 34" A325 THRU 2
CENTERED AT BEAM JOINT 3"
W/ 2" CONT.
PLATE & HSS 3
PLATE & HSS WIDTH OF STEEL
BEAM WELDED TO TOP FLANGE OF 11"
BOLTS (2) EACH (4) 4"
A325 THRU AND ATTACHED W/ (8) 3 "
FILLET WELD 2
3
4 W/ 3 " CONT.
BEAM W/ 1 " CONT. FILLET
SIDE OF BEAM W/ 8" CONT. BOLTS (2)
EACH A325 THRU BOLTS 8 11" BEAM JOINT
WHERE 4
FILLET WELD SIDE
OF BEAM FILLET WELD 2 OCCURS TO
BE AT MID WELD. BOLT 2X PLATE TO
3"
POINT
OF COLUMN STUD W/ WASHER AND NUT. TOP PLATE (MID-SPAN)
HSS COLUMN
1 W-BEAM PER
PLAN
1 1 1/2" = 1'- 0"
PER PLAN WELD 2"
TOP PLATE (MID-SPAN) (4) 3 " A325
THRU 16"X8"X 2" SPLICE PLATE CENTERED
1 1/2" = 1'- 0" 4
AT BEAM JOINT AND ATTACHED W/
TO PLATE W/ 3 "
BOLTS (2)
EACH
4"X4"X12" GUSSET PLATE 8
16"
(8) 3 " A325 THRU BOLTS 16"
CONT. FILLET 4"X4"X1
" GUSSET PLATE 1 1 1 1 SIDE OF BEAM
4 1 1 1 1
WITH 45° ANGLED WELD
2 12" 42" 4" 42" 12"
12" 42" 4" 42" 12"
WITH
45° ANGLED WELD
TO COLUMN CAP & HSS TOP PLATE (END)
5 11"
11"
3 TO
COLUMN CAP & HSS 18"X7"X 8" STEEL 2
2
W/ 8" CONT. FILLET 1 1/2" = 1'- 0"
W/ 3 " CONT. FILLET PLATE WELDED TO
WELD ON BOTH SIDES
8 W18X86 STEEL BEAM
5
WELD ON BOTH SIDES HSS W/ 3 " CONT.
12"X7"X 8" STEEL
8 13
13
HSS COLUMN PER PLAN PLATE WELDED TO
FILLET WELD Ø " 5" 8" 6"X6"X12" GUSSET
PLATE Ø " 5" 8"
HSS
COLUMN PER PLAN 16
16
HSS W/ 38" CONT.
WITH 45° ANGLED
WELD
WALL PLATE SITS ON STEEL BEAM JOISTS ARE HUNG FROM BEAM
21"X10"X5 " STEEL
FILLET WELD
TO COLUMN CAP
& HSS 8
ATTACH PER DETAIL '10' S4 (TYP.)
1
1
ATTACHED HANGERS TO TOP
12" W/ 3 "
CONT. FILLET PLATE WELDED TO 12"
NOTCH GLB ~2"
8
1
FLANGE PER DETAIL '8' S4
1" THICK A36 STEEL PLATE WELD ON BOTH
SIDES HSS W/ 2" CONT. 1" THICK A36 STEEL PLATE
2
FILLET WELD 2
HSS6"X6"X5
" COLUMN
SPLICE PLATE DETAIL
8 SPLICE PLATE DETAIL
1 1/2" = 1'- 0"
1 1/2" = 1'- 0"
(2) 5 " THRU BOLTS
8
13 STEEL BEAM TO HSS COLUMN
14 STEEL BEAM TO HSS COLUMN 15 FLOOR
CONNECTION & STEEL BEAM TO HSS
1
CUT 2" SLIT DOWN MIDDLE
SCALE: 1" = 1'-0" AT BEAM END
SCALE: 1" = 1'-0" AT MID-SPAN SCALE:
1" = 1'-0" AT WEST PARKING MID COLUMN
OF GLB TO SLIP OVER WEB
OF STEEL BEAM
51 " X 117 " GLB
2 8
TOP PLATE OF
WALL BREAKS AT ATTACH STEEL BEAMS
TOGETHER W/ (4) 1 "
STEEL BEAM WEB 2
THRU BOLTS.
BLOCKING BETWEEN
PLATE AND STEEL W14X26 HEADER
51 "
1 2 1 1
BEAM FLANGE HELD UP BELOW
5 1 " 21" 1 " 12"
STEEL BEAM
2X6 PLATE TO STEEL W/ 8" 2 2 2
THREADED STUD WELDED
WITH 1 " FILLET 48" O.C. 11
4 Ø "
16
3
4 "
1 " THICK A36 4 9"
17
WOOD TO STEEL BEAM DETAIL
2
STEEL PLATE
SCALE: 1" = 1'-0"
W-BEAM PER PLAN
3
HSS COLUMN 24"
5 PER PLAN WELD
(2) 8" A325 THRU 1
TO PLATE W/ 1 "
BOLTS (1) EACH 4" 4
SIDE OF BEAM CONT. FILLET
TOP PLATE (HEADERS)
1 1/2" = 1'- 0"
9"X51 "X1 " STEEL PLATE
2 2 51 "
WELDED TO HSS W/ 1 " 2 1
4 23" 23" 12"
CONT. FILLET WELD 4 4
ATTACH WALL STUD 11
TO HEADER PER Ø "
16
DETAIL '30' S2 (TYP.) 3"
HSS COLUMN PER PLAN
11"
3
1 3 "
2" THICK A36 4
STEEL PLATE
3
HSS COLUMN 24"
11"X51 "X1 " STEEL
2 2 PER PLAN WELD
PLATE WELDED TO 1 1"
1 TO PLATE W/ 4" 4
HSS W/ 4" CONT.
CONT. FILLET
FILLET WELD
ATTACH TO CONC. W/ BOTTOM PLATE (HEADERS)
(2) 5 " X 6" TITEN HD 1 1/2" = 1'- 0"
DATE VER.
SCREW ANCHORS8
STRUCTURAL DRAWINGS & DETAILS
BRADLEY ENGINEERING
Engineering VERSION DATE REVISIONS
4/24/2022 1
WWW.BRADLEYENGINEERINGINC.COM
29 STEEL HEADER TO HSS COLUMN
ENGINEERED BY
1 4/24/2022 ORIGINAL PLANS
DAVID BRADLEY, P.E.
L. SCHWEIGERT
11
SCALE: 1" = 1'-0"
PAISLEY LOFTS
811 YEW STREET // BELLINGHAM, WA 98229 Bradley
CHECKED BY
(360) 752-5795
D. BRADLEY
of
105 E. DIVISON STREET
DAVID@BRADLEYENGINEERINGINC.COM
APPROVED BY
D. BRADLEY
ARLINGTON, WA
FOR QUESTIONS & CHANGES PERTAINING TO THIS
PROJECT, CALL ATLUKE (360) 510-9514
SCALE SIZE
S4
DRAWING TO BE PRINTED ON 24"X36" IN ORDER TO BE SCALE
OR EMAIL luke@bradleyengineeringinc.com
AS NOTED D
2X6 STUDS @ 16" O.C.
1-1/2" GYPCRETE
PARAPET HEIGHT
3/4" SUB-FLOOR, GLUED AND 10d NAILS AT 6" O.C., STUDS PER PLAN
1/15/2020
PARAPET WALL HEIGHT
PER ARCH
NAILED WITH 8d AT 6" O.C. ALONG ALTERNATING SIDES TO
1-1/2" GYPCRETE
PER ARCH. DRAWINGS
EDGES, 12" O.C. IN THE FIELD CONNECT 2X6 PLATES
3/4" SUB-FLOOR,
GLUED AND
BALLOON FRAME WALL STUDS
SHEATHING
1/4"X4-1/2" SDS NAILED WITH 8d AT
6" O.C. ALONG
16' O.C. AT ROOF TOP DECK
AND NAILING
SCREWS @ 16" O.C. EDGES, 12" O.C.
IN THE FIELD
NOTCH GLB DOWN 2" AT
2X6 STUDS 16" O.C. SHEATHING
PER SHEAR
ROOF TOP DECK TRANSITION
SLEEPER 16" O.C. TO SLOPE
117 " TJI 210 JOIST @ 16" O.C.
04/24/2022
PER SHEAR WALL PLANS
WALL PLANS
8
DECK TO DRAIN. SHEATHING
11 " GYPCRETE OVER SLEEPER OVER DECKING SLOPED
ON SHEET S5
2
AND WATERPROOF MEMBRANE
3 " SHEATHING TO DRAIN AND WATERPROOF
4
REQUIRED OVER SLEEPERS
BOTTOM FLANGE OF
7 MEMBRANE REQUIRED
11 8" JOISTS PER PLAN
SIMPSON IUS HANGER I-JOIST TO BEARING
117 " TJI 360
3
8
WALL W/ (2) 10d NAILS
4" SHEATHING
JOISTS 16" O.C.
ROOF DECK 2X6 CRIPPLE WALL.
11 " X 117 " LVL OR LSL LEDGER
2 8
CONNECTION PER STUDS 16" O.C.
SCREWED TO EACH STUD WITH
117 " TJI JOISTS
PER PLAN
JOIST TO BEAM W/ IUS HANGER
DETAIL 'X' S5
(3) 1/4"X4-1/2" SIMPSON SDS ATTACH BLOCKING 8
10d NAILS 4" O.C. AROUND
PERIMETER OF DECK DIAPHRAGM
SCREWS TO TOP PLATE W/
VOID SPACE
(2) 16d NAILS ON
EACH SIDE DOUBLE TOP PLATE
(TYP.)
LVL RIM AT INTERIOR AND ROOFTOP
DECK. SCREW LVLS TOGETHER W/ (3)
7
13 " X 117 " LVL TO WALL
31 " SDS SCREWS 24" O.C. LVL'S TO BE
11 8" TJI 360 JOISTS 16" O.C.
4 8
2
STUDS W/ (2) 41 " SDS
CONTINUOUS TO BEARING POINTS BEAR ON
IUS2.37/11.88 HANGER
2 117 " TJI 210 LANDING
SCREWS 16" O.C. 8
2" BLOCK ON LOWERED PLATE (3) STUDS
JOISTS 16" O.C. 21
STAIR LEDGER DETAIL 22 INTERIOR BEARING
13 7 " LVL SCREWED TO
HEIGHT AT ROOFTOP DECK
4" X 11 8
SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0"
WALL STUDS W/ (4) 1 1 "
4" X 4 2
SDS SCREWS 16" O.C.
31 " X 117 " LANDING BEAMS
2 8
HANG JOISTS FROM BEAM
18 FLOOR FRAMING AT DECK DROP
19 FLOOR FRAMING AT DECK DROP
W/ IUS HANGERS
SCALE: 3/4" = 1'-0"
SCALE: 3/4" = 1'-0"
20 THIRD FLOOR LANDING FRAMING
SCALE: 1/2" = 1'-0"
19
20
S5
S5 BALLOON
FRAME STUD WALL AT ROOFTOP DECK UP
PARAPET FOR PARAPET. SEE DETAIL '19' S5 (TYP.)
1 WHERE WALL PLATE SITS 1 1
3 2"X9" GLB OR 6X10 DF #1 HDR ON STEEL BEAM ATTACH3 2"X9" GLB OR 6X10 DF #1 HDR 3 2"X9" GLB
OR 6X10 DF #1 HDR
PER DETAIL '10' S4 (TYP.)
LANDING JOISTS: 117 "
8
TJI 210 JOISTS @ 16" O.C.
31" X 117 " GLB
2 8
IUS HANGERS 11 " X 117 " LVL OR LSL LEDGER TO
(TYP.) 2 8
POCKET BEAM INTO WALL
WALL STUDS W/ (3) 1 " X 41 " SDS
4 2
OR HANG W/ HUCQ412
31" X 117 " GLB SCREWS 16" O.C. SEE DETAIL '21 S5
2 8
IUS HANGERS
LANDING JOISTS: 117 "
TJI 210 JOISTS @ 16" O.C.8
(TYP.)
DOWN
DOWN POCKET BEAM INTO WALL
OR HANG W/ HUCQ412
FRAME STAIRS W/ 2X12
13 " X 117 " LVL TO
STRINGERS @ 12" O.C.
4 8
31 "X117 " GLB HELD UP 31 "X117
" GLB HELD UP 31 "X117 " GLB HELD UP
31 "X117 " GLB HELD UP 31 "X117 " GLB HELD UP 31 "X117 " GLB HELD UP
WALL STUDS W/ (3) 31 "
2 8 BEARING WALL 2
8 2 8
2 8 2 8 BEARING WALL 2 8
2
SDS SCREWS 16" O.C.
DOWN UP
31 "X117 " GLB HELD UP
IUS2.06/11.88 BLOCKING AT INTERIOR
BEARING WALL
IUS2.06/11.88
2 8
DOWN
BLOCKING AT INTERIOR
HANGER (TYP.) BEARING WALL PER
UP
BEARING WALL PER HANGER (TYP.)
DETAIL '22' S5 (TYP.)
DETAIL '22' S5 (TYP.)
BEARING WALL
31 "X117 " GLB HELD UP BEARING WALL
2 8
31" X 117 " GLB
2 8
APPROXIMATE ROOF
DRAIN LOCATION
BLOCKING AT INTERIOR
BEARING WALL PER
IUS2.06/11.88
51 " X 117 " GLB HELD UP
DETAIL '22' S5 (TYP.)
HANGER (TYP.)
2 8 BEARING WALL
4X8 DF HDR
4X8 DF HDR BEARING WALL
18
312"X1178" GLB HELD UP BEARING WALL 312"X1178" GLB HELD
UP 4X8 DF HDR 312"X1178" GLB HELD UP BEARING WALL
312"X1178" GLB HELD UP 312"X1178" GLB HELD UP BEARING WALL 312"X1178" GLB HELD UP
4X8 DF HDR ROOF / DECK SYSTEM
S5 11 7" TJI 360 JOISTS @ 16" O.C. WITH 3/4"
8
T&G SHEATHING GLUED AND NAILED.
ADD SLEEPERS, SHEATHING, AND
3
WATERPROOF MEMBRANE OVER TOP
21'-114"
OF SUB FLOOR AND SLOPE TO DRAIN.
NOTE: FRAME PLATE HEIGHT
OF ALL
INTERIOR WALLS 2" LOWER
THAN
FLOOR SYSTEM
TYPICAL SECOND FLOOR
WALLS
11 7" TJI 210 JOISTS @ 16" O.C. WITH 3/4" T&G SHEATHING
8
GLUED AND NAILED TO JOISTS & 11 " GYPCRETE.
2
BALLOON FRAME STUD WALL AT ROOFTOP DECK UPPARAPET FOR PARAPET. SEE DETAIL '19' S5 (TYP.)
BLOCKING AT INTERIOR
BLOCKING AT INTERIOR
BEARING WALL PER IUS2.06/11.88
IUS2.06/11.88
BEARING WALL PER IUS2.06/11.88
DETAIL '22' S5 (TYP.) HANGER
(TYP.) HANGER (TYP.)
DETAIL '22' S5 (TYP.) HANGER (TYP.)
312"X1178" GLB HELD UP BEARING WALL 312"X1178"
GLB HELD UP 312"X1178" GLB HELD UP BEARING WALL 312"X1178" GLB HELD UP 312"X1178"
GLB HELD UP BEARING WALL 312"X1178" GLB HELD UP 312"X1178" GLB HELD UP
BEARING WALL 312"X1178" GLB HELD UP 31 "X117 " GLB HELD UP BEARING WALL
312"X1178" GLB HELD UP
2 8
BLOCKING AT INTERIOR
BEARING WALL PER
DETAIL '22' S5 (TYP.)
13 " LVL RIM AT DECK AND
4
AT INTERIOR FLOOR
SCREW LVL'S TOGETHER
W/ (3) 31 " SDS SCREWS
2
24" O.C. SEE DETAIL '18' S5
31 "X9" GLB OR 6X10 DF #1 HDR
31 "X9" GLB OR 6X10 DF #1 HDR
2
2
BALLOON FRAME STUD WALL AT ROOFTOP DECK UP
PARAPET FOR PARAPET. SEE DETAIL '19' S5 (TYP.)
19
S5
THIRD FLOOR
FRAMING PLAN
SCALE: 3/16"
= 1' - 0"
NOTES:
DATE VER.
· INTERIOR LOAD BEARING AND EXTERIOR WALL HEADERS TO BE
STRUCTURAL
DRAWINGS & DETAILS BRADLEY ENGINEERING
Engineering 4/24/2022 1
VERSION DATE REVISIONS
4X10 DF #2 UNLESS NOTED OTHERWISE. IN LIEU OF EXTERIOR LOAD
WWW.BRADLEYENGINEERINGINC.COM
ENGINEERED BY
BEARING HEADERS OKAY TO ATTACH JOISTS TO STRUCTURAL RIM
1 4/24/2022 ORIGINAL PLANS
DAVID BRADLEY, P.E.
L. SCHWEIGERT
11
PER DETAIL '23' S6 (TYP. FOR OPENINGS 6 FT OR LESS)
PAISLEY
LOFTS 811 YEW STREET // BELLINGHAM, WA 98229
Bradley CHECKED BY
· INTERIOR BEARING WALL
(360) 752-5795
D. BRADLEY
of
· BEARING FROM ABOVE
105
E. DIVISON STREET DAVID@BRADLEYENGINEERINGINC.COM
APPROVED BY
D. BRADLEY
ARLINGTON,
WA FOR QUESTIONS & CHANGES PERTAINING TO THIS
PROJECT, CALL ATLUKE
(360) 510-9514 SCALE SIZE
S5
DRAWING TO BE PRINTED ON 24"X36" IN ORDER TO BE SCALE
OR EMAIL luke@bradleyengineeringinc.com
AS NOTED
D
7
STUDS PER PLAN STUDS PER PLAN
STUDS PER PLAN
16"
PLY OR OSB
SHEATHING 16d NAILS @ 12" O.C. 16d NAILS @ 12" O.C.
16d NAILS @ 12" O.C.
1/15/2020
7" PLY OR OSB 7" PLY OR OSB
3 CS16,
30" LONG 3/4" SUB-FLOOR 16 3/4" SUB-FLOOR 16
3/4" SUB-FLOOR
1 4" LVL LAID FLAT AGAINST MAIN RIM JOISTS AND @ 5' O.C.
AND AT SHEATHING SHEATHING ENDS
NAILED IN PLACE W/ (3) 10d NAILS @ 16" O.C. EXTEND ALL
CORNERS 1-1/2" GYPCRETE 1-1/2" GYPCRETE AT MIDDLE OF
1-1/2" GYPCRETE
LVL 6" BEYOND OPENING ON EACH SIDE (TYP.)
2X P.T. PLATE
BOTTOM PLATE
EDGE
NAIL PER
EDGE NAIL A
NOTE
BELOW
PER NOTE STRIP OF OSB OR PLY
04/24/2022
2X P.T. PLATE BELOW SHEATHING OVER RIM
SHEATHING A 11-7/8" TJI 210 @ 16" O.C.
11-7/8" TJI 210 @ 16" O.C.
AND FASTENED TO
SPLICE
STANDARD 1-1/4"
BOTTOM PLATE OF
END OF FULL
RIM BEYOND
UPPER WALL AND TOP
STUDS PER PLAN
LENGTH A
PLATE OF LOWER WALL
16d NAILS @ 12" O.C.
EDGE
NAIL PER 11-7/8" TJI 210 @ 16" O.C. SHEATHING
NOTE
BELOW
EDGE NAIL PER 1-1/2" GYPCRETE
DOUBLE TOP PLATE
7
NOTE BELOW
7
DOUBLE TOP PLATE 7" PLY OR OSB DOUBLE TOP PLATE 16" PLY OR OSB
3/4" SUB-FLOOR
11 8" TJI JOISTS @ 16" O.C.
16 SHEATHING ENDS
HUNG FROM LVL WITH IUS 7"
PLY OR OSB SHEATHING
16
AT MIDDLE OF
DOUBLE TOP PLATE
HANGERS @ WINDOW
SHEATHING
TOP PLATE
OPENINGS
11-7/8" TJI 210 @ 16" O.C.
NO HEADER REQUIRED
A SHEATHING JOINT TO BE LOCATED 2" OR MORE A SHEATHING SPLICE IN MIDDLE OF
AT STRUCTURAL RIM 6' MAX WINDOW OPENING
FROM TOP OR BOTTOM EDGE OF RIM JOIST. BOTTOM AND TOP PLATE AS SHOWN
BOARD LOCATIONS SINGLE JACK STUD AND
OPTION A OPTION B OPTION C
SINGLE KING STUD @ EA.
NOTES:
SIDE
STANDARD CRIPPLE
(1) BOTH OF THE OPTIONS SHOWN ABOVE ARE STRUCTURALLY ACCEPTABLE.
SHEATHING CONNECTION
WALL FRAMING W/
(2) IF THE FULL LENGTH SHEATHING EXTENDS OVER THE RIM (NO SHEATHING JOINTS EXISTS IN THE VICINITY OF RIM
PER DETAIL '24' LEFT
STUDS @ 16" O.C.
JOIST, DOUBLE TOP PLATE, AND SOLE PLATE) THEN NEITHER OF THE CONNECTION OPTIONS ARE REQUIRED.
(OPTION 'A', 'B', OR 'C' OK)
(3) SIMILAR CONSTRUCTION WHERE JOISTS RUN THE OPPOSITE DIRECTION SHOWN
SILL
EDGE NAILING:
DOUBLE TOP PLATE
· NON-SHEARWALL (PRESCRIPTIVE/CONVENTIONAL) 8d NAILS @ 6" O.C.
· SHEARWALLS, SEE SHEARWALL TABLE.
23 STRUCTURAL RIM BOARD DETAIL
24 TYPICAL FLOOR TO FLOOR CONNECTION
25 FLOOR CONNECTION WITH
SCALE: 3/4" = 1'-0"
SCALE: 3/4" = 1'-0"
SCALE: 3/4" = 1'-0" JOISTS PARALLEL
BLOCK BETWEEN
112" X 1178" LVL OR LSL LEDGER TO
CANTILEVER JOISTS
WALL STUDS W/ (3) 14" X 412" SDS
OVER WALL
SCREWS 16" O.C. SEE DETAIL '21' S5
LANDING JOISTS: 117 "
8
TJI 210 JOISTS @ 16" O.C.
IUS HANGERS
11 " X 117 " LVL OR LSL LEDGER TO
2 8
POCKET BEAM INTO WALL OR
(TYP.)
WALL STUDS W/ (3) 1 " X 41 " SDS
31" X 117 " GLB
SCREWS 16" O.C. SEE DETAIL '21' S54 2
2 8 HANG W/ HUCQ412
31" X 117 "
GLB
2 8
LANDING JOISTS: 117 "
TJI 210 JOISTS @ 16" O.C.8
IUS HANGERS (TYP.)
DOWN
POCKET BEAM INTO WALL
DOWN
DOWN
OR HANG W/ HUCQ412
FRAME STAIRS W/ 2X12
FRAME STAIRS W/ 2X12
STRINGERS @ 12" O.C.
STRINGERS @ 12" O.C.
31 "X117 " GLB HELD UP 31 "X117 " GLB HELD UP
31 "X117 " GLB HELD UP 31 "X117 " GLB HELD UP 31 "X117 " GLB HELD UP
31 "X117 " GLB HELD UP
2 8 BEARING WALL 2 8
2 8 2 8 2 8
BEARING WALL 2 8
UP
BEARING WALL
IUS2.06/11.88
IUS2.06/11.88 BLOCKING AT INTERIOR
DOWN
BLOCKING AT INTERIOR
BEARING WALL PER HU412
HANGER (TYP.) 31" X 117 " GLB IUS HANGERS
HANGER (TYP.)
BEARING WALL PER 2 8
DETAIL '22' S5 (TYP.)
DETAIL '22' S5 (TYP.) (TYP.)
31" X 117 " GLB
2 8
31" X 117 " GLB
2 8
BLOCKING AT INTERIOR
" GLB8
BEARING WALL PER IUS2.06/11.88
7
DETAIL '22' S5 (TYP.) HANGER (TYP.)
4X8 DF HDR
" X 11
132
312"X1178" GLB HELD UP BEARING WALL 312"X1178" GLB HELD UP 4X8
DF HDR 312"X1178" GLB HELD UP BEARING WALL 312"X1178" GLB HELD UP 312"X1178" GLB HELD UP BEARING
WALL 312"X1178" GLB HELD UP 4X8 DF HDR
FLOOR SYSTEM
11 7" TJI 210 JOISTS @ 16" O.C. WITH 3/4" T&G SHEATHING
8
GLUED AND NAILED TO JOISTS & 11
2" GYPCRETE.
BLOCKING AT INTERIOR
BLOCKING AT INTERIOR
BEARING WALL PER IUS2.06/11.88
IUS2.06/11.88
BEARING WALL PER IUS2.06/11.88
DETAIL '22' S5 (TYP.) HANGER (TYP.)
HANGER (TYP.)
DETAIL '22' S5 (TYP.) HANGER (TYP.)
312"X1178" GLB HELD UP BEARING WALL 312"X1178" GLB HELD UP 312"X1178" GLB HELD
UP BEARING WALL 312"X1178" GLB HELD UP 312"X1178" GLB HELD UP BEARING WALL
312"X1178" GLB HELD UP 312"X1178" GLB HELD UP BEARING WALL 312"X1178" GLB HELD UP
BLOCKING AT INTERIOR
BEARING WALL PER
DETAIL '22' S5 (TYP.)
THIRD FLOOR FRAMING PLAN
SCALE: 3/16" = 1' - 0"
NOTES:
· INTERIOR LOAD BEARING AND EXTERIOR WALL HEADERS TO BE
DATE
VER.
4X10 DF #2 UNLESS NOTED OTHERWISE. IN LIEU OF EXTERIOR LOAD
STRUCTURAL DRAWINGS & DETAILS
BRADLEY ENGINEERING Engineering 4/24/2022
1 VERSION DATE REVISIONS
WWW.BRADLEYENGINEERINGINC.COM
BEARING HEADERS OKAY TO ATTACH JOISTS TO STRUCTURAL RIM
ENGINEERED
BY
1 4/24/2022 ORIGINAL PLANS
PER DETAIL '23' S6 (TYP. FOR OPENINGS 6 FT OR LESS)
DAVID BRADLEY, P.E. L.
SCHWEIGERT 11
· INTERIOR BEARING WALL
PAISLEY LOFTS
811 YEW STREET // BELLINGHAM, WA 98229 Bradley CHECKED
BY
· BEARING FROM ABOVE
(360) 752-5795 D.
BRADLEY of
105 E. DIVISON STREET
DAVID@BRADLEYENGINEERINGINC.COM
APPROVED
BY
D.
BRADLEY
ARLINGTON, WA
FOR QUESTIONS & CHANGES PERTAINING TO THIS
PROJECT, CALL ATLUKE (360) 510-9514 SCALE
SIZE S6
DRAWING
TO BE PRINTED ON 24"X36" IN ORDER TO BE SCALE
OR EMAIL luke@bradleyengineeringinc.com AS
NOTED D
7/16" OSB OR 15/32" PLY
8d AT ON BOTH SIDES
11-7/8" SOLID BLOCKING AT
6" O.C.
8' O.C. IN FIRST TWO BAYS (2) ROWS OF 1/4"X3-1/2" SDS
(OK TO USE 11-7/8" TJI 210 ) SCREWS AT 12" O.C.
1/15/2020
TAPERED RIGID
INSULATION OR INSTALL 2X6 BLOCKING BETWEEN
HUS412 SUB-FASCIA TO EACH RAFTER
(2) 13 " X 111 " LVL OR 31 " X 111 " LVL OVER EDGE OF WALL
HUS412
4 4 2 4
SLEEPERS PER ARCH RAFTERS FOR PARAPET
HANGER W/ (3) 16d NAILS (TYP.) HANGER
ATTACHMENT. CONNECT BLOCKING
1/2" CD SHEATHING NAILED WITH (3) 16d TOE NAILS EACH END
HUS412 ATTACHED TO
HUS412 ATTACHED TO
WITH 8d AT 6" O.C. ALONG
(2) 2X12 OR 13 " X 111 " SUB-FASCIA
3
3
EDGES, 12" O.C. IN THE FIELD. BREAK SHEATHING OVER MIDDLE OF
4 4
DOUBLE 2X12 OR 1 4" X
DOUBLE 2X12 OR 1 4" X
RIM JOIST. NAIL WITH 8d AT 6" O.C.
111 " SUB-FASCIA
1
11-7/8" TJI 210 @ 24" O.C.
4
11 4" SUB-FASCIA
04/24/2022
OR EQUIVALENT 1-1/2" X11-7/8" RIM JOIST
LVL, LSL, PSL... OK (TYP.)
CONNECT TJI RAFTER TO EXTERIOR
WALL DOUBLE TOP PLATE WITH 7/16" OSB OR 15/32" PLY NAILED
8' MAXIMUM CANTILEVER
1/4"X3-1/2" SDS SCREWS AT 12" O.C. WITH 8d AT 6" O.C. ALONG EDGES,
" LVL4 "4
12" O.C. IN THE FIELD (TYP.)
LUS210 HANGER1 1
H1 HURRICANTE TIEREQUIRED
ONEXTERIOR SIDE OFEACH RAFTER (TYP.)
JOISTS PARALLEL
" X 11" X 112 2X12 DF
4 1
TO EXTERIOR WALL
3 #2RAFTERS 16" O.C.
MSTC28 TO STRAP
"
4
(2) 1OR 3LVL END RAFTER 1
EDGE RAFTER TO
" LVL4
WALL STUD
1 " X 11
MSTC28 TO STRAP
2
1
EDGE RAFTER TO (2) STUDS BEHIND
7/16" OSB OR 15/32" PLY
" X 114
MST48 STRAP (TYP.)
3 OR 3
WALL STUD
8d AT 6" O.C.
ON BOTH SIDES
TIE RAFTER TO (2) 2X12 OR 13 " X 111 " SUB-FASCIA
LUS210 HANGERTIE RAFTER TO
MSTC 28 STRAP TOWALL STUD BELOW 4 4 (2) 1 LVL
END RAFTER MSTC 28 STRAP TOWALL STUD BELOW
TAPERED RIGID
INSULATION OR (2) ROWS OF 1/4"X3-1/2" SDS
SLEEPER AS REQUIRED SCREWS AT 24" O.C. (1) INTO
MSTC28 TO STRAP
RIM JOIST (1) INTO RAFTER
WALL STUD TO MAIN
1/2" CD SHEATHING NAILED
HUS412 SUB-FASCIA TO H1 HURRICANTE TIE HUS412
ROOF BEAM BELOW WALL PLATE TO RAFTER
WITH 8d AT 6" O.C. ALONG
HANGER EACH RAFTER REQUIRED ON HANGER
W/ (2) 14" X 312" SDS
EDGES, 12" O.C. IN THE FIELD. BREAK SHEATHING OVER MIDDLE OF
W/ (3) 16d NAILS EXTERIOR SIDE OF
SCREWS 24" O.C. (TYP.)
RIM JOIST. NAIL WITH 8d AT 6" O.C.
(TYP.) EACH RAFTER (TYP.)
11-7/8" TJI 210 @ 24" O.C.
OR EQUIVALENT 1-1/2" X11-7/8" RIM JOIST
LVL, LSL, PSL... OK (TYP.)
NORTH POP UP ROOF FRAMING PLAN
CONNECT EACH TJI RAFTER TO
7/16" OSB OR 15/32" PLY NAILED
EXTERIOR WALL DOUBLE TOP PLATE
WITH (2) #10X4" WOOD SCREWS INTO WITH 8d AT 6" O.C. ALONG EDGES,
SCALE: 3/16" = 1' - 0" OVER FRAMED ON MAIN ROOF
MST48 WALL TO
12" O.C. IN THE FIELD (TYP.)
THE FLANGE (ONE ON EACH SIDE)
WALL STRAP TIE
JOISTS PERPENDICULAR
27
S7 312" X 1178" GLB BELOW EDGE
TO EXTERIOR WALL
OF POP UP WALL IN LINE
WITH MAIN ROOF RAFTERS
26 ROOF PARAPET FRAMING DETAIL
LINE OF NORTH POP UP ROOF ABOVE. SEE
ROOF FRAMING PLAN ON THIS SHEET
SCALE: 3/4" = 1'-0"
27 ROOF POP UP DETAIL
MST48 WALL TO WALL
MST48 WALL TO WALL SCALE: 3/4" = 1'-0"
STRAP TIE ATTACHING
STRAP TIE ATTACHING
POP UP ROOF WALL
POP UP ROOF WALL
TO 4TH FLOOR WALL
TO 4TH FLOOR WALL
MSTC 28 STRAP TO
TIE RAFTER TO WALL
STUD BELOW
MSTC 28 STRAP TO TIE SCREW WALL PLATE DOWN TO RAFTER
MSTC 28 STRAP TO TIE
11 " X 117 " LVL OR LSL LEDGER TO
LUS210 HANGER
W/ (2) 1 " X 31 " SDS SCREWS 24" O.C.
2 8
WALL STUDS DOWN 4 2
WALL STUDS DOWN
WALL STUDS W/ (3) 1 " X 41 " SDS
TO BEAM BELOW
TO BEAM BELOW
SCREWS 16" O.C. 4 2
BEARING WALL
LANDING JOISTS: 117 " TJI 210 HUS412
HUS412
8
(2) 13 " X 111 " LVL OR 31 "
JOISTS @ 16" O.C. HANGER
4 4 2 HANGER
X 111 " LVL END RAFTER
4
1 7 POCKET BEAM INTO WALL OR
32" X 11 8" GLB
SUB-FASCIA TO
1 7
HANG W/ HUCQ412
3 2" X 11 8" GLB
EACH RAFTER
31 " X 117 " GLB
BELOW EDGE OF
SUB-FASCIA TO
W/ (3) 16d NAILS
2 8
" SUB-FASCIA
BELOW EDGE OF
POP UP ROOF
EACH RAFTER 4
(TYP.)
IUS HANGERS (TYP.) 1
POP UP ROOF
W/ (3) 16d NAILS
DOWN
(TYP.)
" X 11
DOWN 4
3
" SUB-FASCIA
FRAME STAIRS W/ 2X12
14
STRINGERS @ 12" O.C.
312"X1178" GLB HELD UP BEARING WALL 312"X1178"
GLB HELD UP BEARING WALL 312"X1178" GLB HELD UP
312"X1178" GLB HELD UP 312"X1178" GLB HELD UP BEARING WALL 312"X1178" GLB HELD UP
" X 11
2X12 DF 4
3
31 "X117 " GLB HELD UP
2 8 (2) 2X12 OR 1
BLOCKING BETWEEN
BLOCKING BETWEEN
BLOCKING BETWEEN
#2RAFTERS 16" O.C.
RAFTERS OVER RAFTER TO BEARING
RAFTERS OVER
RAFTERS OVER
BEARING WALL (TYP.) WALL W/ (2) 10d
BEARING WALL
(TYP.) BEARING WALL (TYP.)
NAILS (TYP.)
H1 HURRICANTE TIE
(2) 2X12 OR 1
REQUIRED ON
BLOCKING BETWEEN
117 " TJI 210 EXTERIOR SIDE OF
H1 HURRICANTE TIE
RAFTERS OVER
JOISTS @ 16" O.C.8 EACH RAFTER (TYP.)
REQUIRED ON
":1'-0" BLOCKING BETWEEN
":1'-0" RAFTER TO BEARING
BEARING WALL (TYP.) ":1'-0"
EXTERIOR SIDE OF
14 RAFTERS OVER
14 WALL W/ (2) 10d
14
HUS412
EACH RAFTER (TYP.)
HANGER (2) 13 " X 111 " LVL OR
31 "
BEARING WALL (TYP.)
NAILS (TYP.)
4 4
2
X 111 " LVL END RAFTER
HUS412
4X8 DF HDR
4
HANGER
312"X1178" GLB HELD UP BEARING WALL 312"X1178" GLB HELD
UP 4X8 DF HDR 312"X1178" GLB HELD UP 312"X1178" GLB HELD UP BEARING WALL
312"X1178" GLB HELD UP 312"X1178" GLB HELD UP BEARING WALL 312"X1178" GLB HELD UP
4X8 DF HDR
RAFTER TO BEARING
28
28
LUS210 HANGER
WALL W/ (2) 10d
S7
S7
NAILS (TYP.)
117 " TJI 210 RAFTERS 24" O.C.
":1'-0"
":1'-0" 8
":1'-0"
MSTC 28 STRAP TO
4
4
4
1
1
1
TIE RAFTER TO WALL
STUD BELOW
EAST STAIRWELL ROOF FRAMING
SCALE: 3/16" = 1' - 0"
RAFTER TO BEARING
BLOCKING BETWEEN
BLOCKING BETWEEN
WALL W/ (2) 10d
BLOCKING BETWEEN CUT TOP FLANGE OF
RIDGE ALIGNED WITH
RAFTERS OVER
RAFTERS OVER
RAFTERS OVER
BEARING WALL (TYP.)
BEARING WALL (TYP.)
NAILS (TYP.)
BEARING WALL (TYP.) I-JOIST OVE BEARING
EDGE OF BEARING
TO MATCH ROOF SLOPE
WALL BELOW
312"X1178" GLB HELD UP BEARING WALL 312"X1178"
GLB HELD UP 312"X1178" GLB HELD UP BEARING WALL 312"X1178" GLB HELD UP 312"X1178"
GLB HELD UP BEARING WALL 312"X1178" GLB HELD UP 312"X1178" GLB HELD UP
BEARING WALL 312"X1178" GLB HELD UP 1 ":1'-0"
1
4
4":1'-0"
RAFTER TO BEARING
RAFTER TO BEARING
WALL W/ (2) 10d
WALL W/ (2) 10d
NAILS (TYP.)
NAILS (TYP.)
312" X 1178" GLB
31 " X 117 " GLB
LAP RAFTERS OVER
BELOW EDGE OF
BELOW EDGE OF2 8
BLOCK BETWEEN RAFTERS
BEARING WALL
POP UP ROOF
POP UP ROOF
MSTC 28 STRAP TO TIE
MSTC 28 STRAP TO TIE
117 " TJI 210 RAFTERS 24" O.C.
WALL STUDS DOWN
WALL STUDS DOWN
ATTACH BLOCKING TO
8
TO BEAM BELOW
TO BEAM BELOW
TOP PLATE W/ (2) 16d
SCREW BOTTOM FLANGE OF
NAILS ON EACH SIDE
EACH I-JOIST TO 2X8 PLATE
W/ (2) 31 " #10 SCREWS
2X6 STUDS 16" O.C.
2
MST48 WALL TO WALL
MST48 WALL TO WALL
STRAP TIE ATTACHING
STRAP TIE ATTACHING
28 RAFTERS AT RIDGE DETAIL
POP UP ROOF WALL
POP UP ROOF WALL
TO 4TH FLOOR WALL
TO 4TH FLOOR WALL
SCALE: 3/4" = 1'-0"
ROOF FRAMING PLAN
LINE OF SOUTH POP UP ROOF ABOVE. SEE 'NORTH POP
UP
ROOF FRAMING PLAN' ON THIS SHEET. THIS SOUTH POP
UP
SCALE: 3/16" = 1' - 0"
ROOF SHALL BE FRAMED EXACTLY THE SAME AS NORTH ROOF.
27
NOTES:
S7
DATE VER.
· INTERIOR LOAD BEARING AND EXTERIOR WALL HEADERS TO BE
STRUCTURAL
DRAWINGS & DETAILS BRADLEY ENGINEERING
Engineering 4/24/2022 1
VERSION DATE REVISIONS
4X10 DF #2 UNLESS NOTED OTHERWISE. IN LIEU OF EXTERIOR LOAD
WWW.BRADLEYENGINEERINGINC.COM
ENGINEERED BY
1 4/24/2022 ORIGINAL PLANS
BEARING HEADERS OKAY TO ATTACH JOISTS TO STRUCTURAL RIM
DAVID BRADLEY, P.E.
L. SCHWEIGERT
11
PER DETAIL '23' S6 (TYP. FOR OPENINGS 6 FT OR LESS)
PAISLEY
LOFTS 811 YEW STREET // BELLINGHAM, WA 98229
Bradley CHECKED BY
· INTERIOR BEARING WALL
(360) 752-5795
D. BRADLEY
of
105
E. DIVISON STREET DAVID@BRADLEYENGINEERINGINC.COM
· BEARING FROM ABOVE
APPROVED BY
D. BRADLEY
ARLINGTON,
WA FOR QUESTIONS & CHANGES PERTAINING TO THIS
PROJECT, CALL ATLUKE
(360) 510-9514 SCALE SIZE
S7
DRAWING TO BE PRINTED ON 24"X36" IN ORDER TO BE SCALE
OR EMAIL luke@bradleyengineeringinc.com
AS NOTED
D
SHEAR WALL TABLE
UP TO
SHEATHING ON EDGE NAILING /
LATERAL RESISTANCE (PLF) HDU4
PANEL EDGES BLOCKED
ADJOINING PANEL EDGE
ADJOINING PANEL EDGE
1/15/2020
WALL ONE OR BOTH NAIL SIZE FIELD NAILING LOAD
TRANSFER
SHEATHING OR UNBLOCKED 2
FASTEN TO POST WITH
SIDES OF WALL DISTANCE (MAX)
3 WIND SEISMIC OKAY TO USE
SIMPSON CNW
(10) 1/4"X2-1/2" SDS FOR HDU4
7 " OSB OR 15 "
COUPLER TO
PW 16 32 ONE UNBLOCKED 8d 6" / 12" O.C.
NO 300 240 EXTEND ROD.
PLY 1
7 " OSB OR 15 "
SW0 16 32 ONE BLOCKED 8d 3" / 12" O.C.
YES 685 490
3" MIN WOOD THICKNESS ADJOINING PANEL EDGE ADJOINING PANEL EDGE
04/24/2022
PLY 1 4
7 " OSB OR 15 "
SIMPSON HDU5 OR HDU2 PER PLAN NOTE: STAGGER PANEL EDGE ON EITHER SIDE OF NOTE: MINIMUM
3X STUD IN WALL AT ADJOINING
16 32
SW4 ONE BLOCKED 8d 3" / 12" O.C.
YES 685 490
WALL TO PREVENT SPLITTING OF 2X WALL STUD SHEATHING
MEMBERS TO PREVENT SPLITTING
PLY 1
(2) 3" WASHER AND
P.T. SILL PLATE
7 " OSB OR 15 "
NUT ON BOTTOM
A. ADJOINING PANEL EDGES STAGGERED B. ADJOINING PANEL EDGES
NOT STAGGERED
SW8 16 32 BOTH BLOCKED 8d 3" / 12" O.C.
YES 1370 980 OF THREADED ROD.
PLY 1
AS SHOWN.
SIMPSON SSTB20 OR
1 5d cooler or
5/8" ROD ALTERNATIVE
IW 2" GWB BOTH UNBLOCKED 7" / 7" O.C.
NO 200 200
wallboard nail
PER DETAIL AT LEFT DETAIL FOR ADJOINING PANEL EDGES WHERE STRUCTURAL
1 #6 Type S or W
GW3 2" GWB BOTH BLOCKED 4" / 16" O.C.
NO 320 320
1-1/4" Screws
PANELS ARE APPLIED TO BOTH FACES OF THE WALL
1 PLY = CDX, C-C, OR C-D PLYWOOD. OSB OF SIMILAR THICKNESS AND SPAN RATING MAY BE SUBSTITUTED FOR PLYWOOD.
5/8" ROD ALTERNATIVE TO SSTB20
2 NAILS SHALL BE COMMON OR GALVANIZED BOX, UNLESS NOTED OTHERWISE.
3 FOR WALLS DESIGNED TO HAVE LOADS TRANSFERRED AROUND THE WINDOW OPENINGS, DOUBLE STUDS MUST BE PLACED
ON EITHER SIDE OF EACH WINDOW WITH EDGE NAILING ALONG BOTH STUDS.
31 SIMPSON HDU5 HOLD DOWN DETAIL
REVISIONS
4 NO HOLD-DOWNS ARE REQUIRED FOR THIS SHEAR WALL
SCALE: N.T.S.
TYPICAL
ORIGINAL PLANS
NOTES:
(1) UNLESS NOTED OTHERWISE, ALL EXTERIOR WALLS SHALL BE
A B C D
E F G H
I J K
L
CONSTRUCTED IN ACCORDANCE WITH PW (PRESCRIPTIVE WALL).
(2) ALL CONNECTIONS NOT SHOWN ABOVE, SHALL CONFORM TO
HDU4 HOLD HDU4 HOLD
HDU4 HOLD HDU4 HOLD HDU4 HOLD
HDU4 HOLD HDU4 HOLD
IBC TABLE 2304.9.1.
DOWN PER DOWN PER
DOWN PER DOWN PER DOWN PER
DOWN PER DOWN PER
DETAIL '31' S8 DETAIL '31' S8
DETAIL '31' S8 DETAIL '31' S8 DETAIL '31' S8
DETAIL '31' S8 DETAIL '31' S8
1
DATE
SW8
SW4 SW4 SW4 SW4
SW0 SW0 SW4
4/24/2022
SHEAR WALL LEGEND
SW4
SW8
SW8
PER SHEAR WALL TABLE, S8
HDU4 HOLD
1
SW8
EXTERIOR WALLS ARE PW, PRESCRIPTIVE WALL,
DOWN PER
UNLESS NOTED OTHERWISE. 7/16" OSB OR 15/32"
DETAIL '31' S8
VERSION
PW = PLY ON ONE SIDE OF WALL, UNBLOCKED, 8d
HDU4 HOLD
SW4 SW4
NAILS AT 6" O.C. ALONG EDGES, 12" O.C. IN THE
DOWN PER
DETAIL '31' S8 SW8
1 D
FIELD. NO HOLD DOWNS REQUIRED.
VER. SIZE
SW4
7/16" OSB OR 15/32" PLY ON ONE SIDE OF WALL,
SW4 = BLOCKED, 8d NAILS AT 3" O.C. ALONG EDGES, 12"
O.C. IN THE FIELD. HOLD DOWNS ARE REQUIRED.
SW8
HDU4 HOLDDOWN PERDETAIL '31' S8
HDU4 HOLD
SW8
7/16" OSB OR 15/32" PLY ON ONE SIDE OF WALL,
DOWN PER
SW8
SW0 =
DETAIL '31' S8
BLOCKED, 8d NAILS AT 3" O.C. ALONG EDGES, 12"
4/24/2022L. SCHWEIGERTD. BRADLEYD. BRADLEYAS NOTED
O.C. IN THE FIELD. NO HOLD DOWNS REQUIRED.
DATE ENGINEERED BYCHECKED BYAPPROVED BYSCALE
2 SW8
7/16" OSB OR 15/32" PLY ON BOTH SIDES OF WALL,
SW8 = BLOCKED, 8d NAILS AT 3" O.C. ALONG EDGES, 12"
O.C. IN THE FIELD. HOLD DOWNS ARE REQUIRED.
3
SW8 SW8
HDU4 HOLD
SW8 SW8
SW8 SW4 HDU4 HOLD HDU4 HOLD DOWN
DOWN PER
DOWN PER PER DETAIL '31' S8
DETAIL '31' S8
DETAIL '31' S8
HDU4 HOLD
HDU4 HOLD
HDU4 HOLDDOWN PERDETAIL '31' S8
DOWN PER
SW8 DOWN PER
DETAIL '31' S8
SW8
DETAIL '31' S8
SW0
Engineering
SW8
SW0
(12) 10d NAILS MIN
END
Bradley
CONNECT MST48 TO LENGTH
DOUBLE STUDS
SW8 HDU4 HOLDDOWN PERDETAIL '31' S8
SW8 SW8 SW8
4
SW8
HDU4 HOLD
3/4" SUBFLOOR CLEAR
DOWN PER
HDU4 HOLD HDU4 HOLD
SPAN
DETAIL '31' S8
DOWN PER DOWN PER
DETAIL '31' S8 DETAIL '31' S8
RIM JOIST
NO NAILS REQUIRED
FIRST FLOOR SHEAR WALL & HOLD DOWN PLAN
AT RIM JOIST
SCALE: 1/8" = 1' - 0"
END
DOUBLE TOP PLATE LENGTH
A B C D
E F G H
I J K
L
(360) 510-9514
MSTC48B3 PER
(12) 10d NAILS MIN
MSTC48B3 PER MSTC48B3 PER MSTC48B3 PER
MSTC48B3 PER MSTC48B3 PER
MSTC48B3 PER DETAIL '33' S8 DETAIL '33' S8 DETAIL '33' S8
DETAIL '33' S8 DETAIL '33' S8 DETAIL '33' S8
DETAIL '33' S8
MST48 PER MST48 PER
SW4 SW4 SW4 SW4
SW0 SW0 SW4 SW4 SW0
SW4 DETAIL '32' S8 DETAIL '32' S8
1 SW0 SW0
SW0 SW0
SW4 SW0 SW0 SW4
MST48 PER
· STRAP TO BE INSTALLED DIRECTLY ON TOP OF SHEATHING
DETAIL '32' S8 LUKE
SW4
SW4
32 MST48 FLOOR TO FLOOR STRAP-TIE
luke@bradleyengineeringinc.com
N.T.S.
MST48 PER DETAIL '32' S8 PLACE
STRAP ON INSIDE OR OUTSIDE OF
STAIR WELL WALL, WHICHEVER
SIDE SHEATHING IS APPLIED
SW4 SW4
BRADLEY ENGINEERINGWWW.BRADLEYENGINEERINGINC.COMDAVID BRADLEY, P.E.811 YEW STREET // BELLINGHAM, WA 98229(360)
752-5795DAVID@BRADLEYENGINEERINGINC.COMFOR QUESTIONS & CHANGES PERTAINING TO THISPROJECT, CALL ATOR EMAIL
MSTC48B3 PER
DETAIL '33' S8 SW4 SW4
SW4
10d NAILS
MST48 PER
SW4 DETAIL '32' S8
CONNECT MSTC48B3 TO
DOUBLE STUDS
MSTC48B3 PER SW4
DETAIL '33' S8
2
3/4" SUBFLOOR
MST48 PER DETAIL
'32' S8 PLACE UNLESS NOTED OTHERWISE INTERIOR WALLS HAVE MST48 PER DETAIL '32' S8 PLACE
STRAP ON INSIDE
OR OUTSIDE OF 1/2" GWB ON BOTH SIDES WITH NO SPECIAL NAILING STRAP ON INSIDE OR OUTSIDE
OF
RIM JOIST
STAIR WELL
WALL, WHICHEVER REQUIRED. ADDITIONAL LAYERS OF SHEETROCK OK STAIR WELL WALL, WHICHEVER
SIDE SHEATHING
IS APPLIED PER ARCH. FOR FIRE CODE REASONS SIDE SHEATHING IS APPLIED
PRE BENT STRAP WRAPS
3
AROUND BEAM OR RIM JOIST
MSTC48B3 PER
RIM JOIST OR BEAM
DETAIL '33' S8 SW4
· STRAP TO BE INSTALLED DIRECTLY ON TOP OF
SHEATHING. SHEATHING NOT SHOWN FOR CLARITY
MST48 PER
SW4 DETAIL '32' S8
MSTC48B3 PER
33 MSTC48B3 STRAP-TIE
DETAIL '33' S8 SW4
N.T.S.
SW4 MST48 PER
SW4
SW4 SW4 SW4
SW4 SW0 SW4
DETAIL '32' S8
4 SW4
SW4 SW4 SW4
SW4 SW0 SW4 SW4
SW0 SW4
MSTC48B3 PER
MST48 PER
MST48 PER
MST48 PER MST48 PER
DETAIL '33' S8
MSTC48B3 PER DETAIL '32' S8
DETAIL '32' S8
DETAIL '32' S8 DETAIL '32' S8
MSTC48B3 PER
MSTC48B3 PER MSTC48B3 PER MSTC48B3
PER MSTC48B3 PER
DETAIL '33' S8
DETAIL '33' S8
DETAIL '33' S8 DETAIL '33' S8 DETAIL '33'
S8 DETAIL '33' S8
STRUCTURAL DRAWINGS & DETAILSPAISLEY LOFTS105 E. DIVISION STREETARLINGTON, WA
SECOND FLOOR SHEAR WALL & HOLD DOWN PLAN
SCALE: 1/8" = 1' - 0"
S8 of 11
DRAWING TO BE PRINTED ON 24"X36" IN ORDER TO BE SCALE
1/15/2020
04/24/2022
A B C D
E F G H
I J
MST48 PER
SHEATHING BOARD SPLICE LINES
MST48 PER MST48 PER MST48 PER
MST48 PER MST48 PER
MSTC48B3 PER DETAIL '32' S8 DETAIL '32' S8 DETAIL '32' S8
DETAIL '32' S8 DETAIL '32' S8 DETAIL '32' S8
DETAIL '33' S8
SW4 SW0 SW4 SW4
SW0 SW0 SW4 SW4 SW0
SW4
24" LONG CS16 STRAP TYING TWO
1
SHEATHING BOARDS TOGETHER,
SW0 SW0
SW0 SW0
12" OF COVERAGE ON EACH
SW4
BOARD, TO BE PLACED ABOVE
AND BELOW ALL OPENINGS
SW0
MST48 PER DETAIL '32' S8 PLACE
SHEATHING SPLICE THAT
STRAP ON INSIDE OR OUTSIDE OF
REVISIONS
LANDS ON EDGE OF ALL
STAIR WELL WALL, WHICHEVER
ORIGINAL PLANS
OPENINGS REQUIRES CS16
SIDE SHEATHING IS APPLIED
STRAP ABOVE AND BELOW
OPENING(S)
SW4 MST48 PER
DETAIL '32' S8
SW4
SW4
SW0
WINDOW OR DOOR
SW4
OPENING PER PLAN
DATE
SW4
4/24/2022
MST48 PER
DETAIL '32' S8
USE CS16 STRAPS AT EVERY
2
SHEATHING BOARD SPLICE THAT
MST48 PER DETAIL
'32' S8 PLACE UNLESS NOTED OTHERWISE INTERIOR WALLS HAVE MST48 PER DETAIL '32' S8 PLACE
SW0 SW0
1
LANDS ABOVE OR BELOW ALL
STRAP ON INSIDE
OR OUTSIDE OF 1/2" GWB ON BOTH SIDES WITH NO SPECIAL NAILING STRAP ON INSIDE OR OUTSIDE
OF
OPENINGS, INCLUDING ON EDGE
STAIR WELL
WALL, WHICHEVER REQUIRED. ADDITIONAL LAYERS OF SHEETROCK OK STAIR WELL WALL, WHICHEVER
OF OPENINGS (DEMONSTRATED
SIDE SHEATHING
IS APPLIED PER ARCH. FOR FIRE CODE REASONS SIDE SHEATHING IS APPLIED
MSTC48B3 PER
VERSION
DETAIL '33' S8
AT THE LEFT SPLICE)
3
MST48 PER
1 D
VER. SIZE
DETAIL '32' S8 SW4
CS16 LATERAL STRAPPING NOTES:
· MST48 VERTICAL STRAPS TO BE INSTALLED ON TOP OF CS16
LATERAL STRAPS
SW4
· ANY OPENING IN THE EXTERIOR WALL SHEATHING REQUIRES
LATERAL STRAPPING AT PLY BREAKS PER THIS DETAIL
35 CS16 LATERAL STRAPPING DETAIL
SW0
4/24/2022L. SCHWEIGERTD. BRADLEYD. BRADLEYAS NOTED
SCALE: N.T.S.
DATE ENGINEERED BYCHECKED BYAPPROVED BYSCALE
REQUIRED AT ALL OPENINGS
MSTC48B3 PER
DETAIL '33' S8
MSTC48B3 PER
SW4
SW4 SW4 SW4
DETAIL '33' S8
4
SW4
SW4
SW4 SW0 SW4
SW4 SW0 SW4 SW4
SW0 SW4
MSTC48 PER
MST48 PER
MST48 PER
DETAIL '32' S8
MST48 PER DETAIL '32' S8
DETAIL '32' S8
MST48 PER
MST48 PER MST48 PER MST48 PER
MST48 PER
Engineering
DETAIL '32' S8
DETAIL '32' S8
DETAIL '32' S8 DETAIL '32' S8 DETAIL '32'
S8 DETAIL '32' S8
THIRD FLOOR SHEAR WALL & HOLD DOWN PLAN
SCALE: 1/8" = 1' - 0"
Bradley
A B C D
E F G H
I J
PW PW PW PW
PW PW PW PW PW
PW
(360) 510-9514
1
PW PW
PW PW
PW
PW
LUKE
luke@bradleyengineeringinc.com
PW
PW
BRADLEY ENGINEERINGWWW.BRADLEYENGINEERINGINC.COMDAVID BRADLEY, P.E.811 YEW STREET // BELLINGHAM, WA 98229(360)
752-5795DAVID@BRADLEYENGINEERINGINC.COMFOR QUESTIONS & CHANGES PERTAINING TO THISPROJECT, CALL ATOR EMAIL
PW
2
PW PW
UNLESS NOTED OTHERWISE INTERIOR WALLS HAVE
1/2" GWB ON BOTH SIDES WITH NO SPECIAL NAILING
REQUIRED. ADDITIONAL LAYERS OF SHEETROCK OK
PER ARCH. FOR FIRE CODE REASONS
3
PW
PW
PW
PW
PW PW PW
PW
4 PW
PW PW PW
PW PW PW PW
PW PW
STRUCTURAL DRAWINGS & DETAILSPAISLEY LOFTS105 E. DIVISION STREETARLINGTON, WA
FOURTH FLOOR SHEAR WALL & HOLD DOWN PLAN
SCALE: 1/8" = 1' - 0"
S9 of 11
DRAWING TO BE PRINTED ON 24"X36" IN ORDER TO BE SCALE
1/15/2020
04/24/2022
REVISIONS
ORIGINAL PLANS
DATE
4/24/2022
1
VERSION
1 D
VER. SIZE
4/24/2022L. SCHWEIGERTD. BRADLEYD. BRADLEYAS NOTED
DATE ENGINEERED BYCHECKED BYAPPROVED BYSCALE
Engineering
Bradley
(360) 510-9514
LUKE
luke@bradleyengineeringinc.com
THE ARCHITECTURAL DRAWINGS ON THIS SHEET
ARE THE BASIS FOR STRUCTURAL
ANALYSIS AND DESIGN. THE DRAWINGS WERE PROVIDED
BY GLENN C. WELLS, A.I.A. AND
RECEIVED ON 4/11/2022. THESE DRAWINGS HAVE BEEN
SCALED DOWN TO 1/16" = 1'-0" U.N.O.
BRADLEY ENGINEERINGWWW.BRADLEYENGINEERINGINC.COMDAVID BRADLEY, P.E.811 YEW STREET
// BELLINGHAM, WA 98229(360) 752-5795DAVID@BRADLEYENGINEERINGINC.COMFOR QUESTIONS & CHANGES PERTAINING TO THISPROJECT, CALL ATOR EMAIL
SCALE TO FIT ON THIS SHEET. USE A PDF VIEWER
TO ZOOM IN TO READ TEXT. CONTACT
THE ENGINEER OF RECORD IF THE FINAL ARCHITECTURAL
DRAWINGS VARY FROM THE
DRAWINGS SHOWN. ENGINEER SHALL BE NOTIFIED
OF ALL STRUCTURAL CHANGES.
THE INFORMATION ON THIS PAGE IS NOT A PART
OF THE STRUCTURAL REQUIREMENTS.
STRUCTURAL DRAWINGS & DETAILSPAISLEY LOFTS105 E. DIVISION STREETARLINGTON, WA
S10 of 11
DRAWING TO BE PRINTED ON 24"X36" IN ORDER TO BE SCALE
ABBREVIATIONS (Used throughout structural drawings)
STANDARD STRUCTURAL SPECIFICATIONS - 2018 IBC
(E) Existing C.S. Clear Span INT. Interior STD Standard
1/15/2020
(N) New DBL Double MAX Maximum STR'L Structural
INTRODUCTION FOUNDATION
A.B. Anchor Bolt EOR Engineer of Record MANUF. Manufacturer S.S. Select Structural
WOOD FRAMING
The Standard Structural Specifications are guidelines and structural requirements for construction of typical
ARCH Architectural ELEV. Elevation MIN Minimum T.O. Top Of
commercial, multi-family, and industrial (i.e. all non-residential) structures. The intent of this document is to · Design Soil Bearing Pressure
= 1,500 psf Default Wood Types: Unless noted otherwise, the material for a structural member is
as shown:
BLDG Building EXT. Exterior N/A Not Applicable TJI Trus Joist, I Series
provide general structural requirements for the project. Builder, contractor, and other parties involved are · Frost Zone Depth = 18
inches · Beams, Posts, & Sawn Joists............. Douglas Fir #2 (D.F.2)
BLKG Blocking FDN Foundation O.C. On Center TPL Triple
04/24/2022
required to read this document and are responsible for meeting the requirements specified within. Contact the
· Studs & Plates ................................... Hem/Fir (H.F.) or Douglas
Fir (D.F.)
engineer of record with any questions or concerns. · Unless noted otherwise,
concrete is designed with 2,500 psi strength and does not require special inspection.
BM Beam FTG Footing Opp. Opposite TYP. Typical
· Mud Sill (i.e. Sill Plate) ....................... Pressure Treated (P.T.)
The specified concrete
strength (3,000 psi) is greater than design strength (2,500 psi)
BTM Bottom GALV. Galvanized PLY Plywood U.N.O. Unless Noted Otherwise
· Blocking ............................................. Any solid 2X or rim
joist material
Code: Cast-in-place concrete
sizing, placing, and testing shall conform to ACI 318-19 and ACI 301-16
C C Channel (Steel) GA. Gauge P.T. Pressure Treated V.B. Vapor Barrier
DESIGN CRITERIA
· Rim Joists .......................................... Douglas Fir #2 (D.F.2)
for solid sawn, manufactured rim for I-joists
Geotechnical Report: Bradley
Engineering strongly recommends that a geotechnical report be performed by a
· Glued-Laminated (dry-use) ................ D.F. 24F-V4 (GLB)
CL Center Line HDR Header REINF. Reinforced VERT. Vertical
DESIGN PARAMETER VALUE SOURCE qualified geotechnical engineer
for all land based construction projects.
· Exposed Structural Members ............ Pressure Treated (P.T.)
CMU Conc. Masonry Unit HORIZ. Horizontal REQ'D Required W/ With
Seismic Design Category 'D' IBC 1613 Earthwork: Call before you
dig! Call '811'. Locate and protect underground conduit, plumbing, and other utilities where · Glued-Laminated (wet-use) ............... Treat with Hi-Clear II by Permapost
Products Co. in Hillsboro, OR CONC. Concrete HSS Hollow Structural Section SIM. Similar W/O Without
new work is performed. Footings
shall bear on undisturbed native soils and/or stuctural fill compacted in lifts of one
Risk Category 'II' IBC Table 1604.5 foot or less to 95% of a modified
proctor per ASTM D1557. Soils shall be firm and unyielding. All organic and Moisture Content: The max moisture content shall be 19% at the time of installation of
connectors, nails, and bolts CONT. Continuous INSUL. Insulation SPECS Specifications WF Wide Flange (Steel)
Wind Exposure Category 'B' IBC 1609.4.3 deleterious material beneath
the footings, foundations, and slabs to be removed and replaced with 4" min. crushed for framing members.
LATERALBasic Wind Speed (3-second gust) 110 MPH IBC Figure 1609.3(1) rock compacted to 95% relative
compaction. Pressure Treated Lumber: All members in contact with earth/concrete or exposed to the
elements shall be pressure WOOD FRAMING CONNECTORS
treated or preservative treated (P.T.). Colorless end sealer shall be applied
immediately to the ends of members
Design Wind Load 16.00 PSF ASCE 7-16 28.6-1 Structural Fill: Structural
fill consists of clean, well-graded sandy gravel, gravelly sand, or other approved naturally
REVISIONS
after fabrication and field trimming. Glulam beams (GLB's) which are exposed to
the elements shall be treated with
occurring granular material
(e.g. pit run) with at least 30 percent retained on the No. 4 sieve, or a well-graded crushed
Manufacturer: Simpson Strong-Tie construction connectors are specified, however, any nationally recognized brand
ORIGINAL PLANS
LOAD SOURCE LIVE LOAD DEAD LOAD
Hi-Clear II by Permapost Products Co located in Hillsboro, OR.
(e.g. Silver, KC, etc) may be used if they are equivalent in their ability to carry all applied loads in all orientations.
rock. In wet weather conditions,
fill should have less than 5% fines. Soils with an over-optimum moisture content
Blocking: Provide 2X or engineered lumber full depth solid blocking between joists
and rafters at beam and bearing
Roofs 20 psf 15 psf should be scarified (i.e.
turn over the soil) and dried during periods of dry weather or replaced with drier structural fill.
wall locations. Blocking is required at all bearing locations. Trusses, structural
composite lumber, glued-laminated Installation: All prefabricated items shall be installed in strict accordance with the manufacturer's recommendations
Floors 40 psf 12 psf Surface Drainage: Finished
grades are to be at least 6" below top of stem wall. Lots shall be graded to drain surface members, and I-joists shall be supported laterally as required by the manufacturer's
recommendations. and requirements (locations, exposure, end and edge distances, fasteners, etc.).
Decks & Balconies 60 psf 10 psf water away from foundation
walls. The grade shall fall a minimum of 6 inches within 10 feet. If 6 inches of fall is not Bearing: For beams bearing on perpendicular walls or columns, Use a minimum 3"
bearing length unless noted Simpson Connectors: Unless noted otherwise on the structural drawings and details, the following Simpson
possible, grade shall be sloped
min 2 percent away from the building.
Ground Snow Load 25 psf -
otherwise. Use enough studs to match or exceed beam width unless noted otherwise.
Strong-Tie construction connectors shall be used:
DATE
VERTICALExterior Wall - 12 psf Footings: All footings shall
conform to accompanying structural details. Specified footing dimensions are minimums Headers: Unless noted otherwise, headers to be 4x10 D.F.2, (2) 2x10 D.F.2, or 6x8
D.F.1
· Post Caps: CBTZ, PCZ/EPCZ, BC/BCS, CC, CCQ, ECC, ECCQ
4/24/2022
Interior Wall - 10 psf unless noted otherwise. Bottom
of footings to be below frost zone (18"). Glued Laminated Members: Glulam beams (GLB) shall be Douglas Fir-Larch, 24F-V4, dry
use only
· Post Bases: CPTZ, CBSQ, PB/PBS, ABA/ABU/ABW
Footing Drains: Providing
adequate drainage to retaining and basement walls is imperative. Footing drains shall be Engineered Lumber: Install per the relevant manufacturer's installation guides
for each type:
Vertical loads come from 2015 IBC Table 1607.1, Minimum Uniformly Distributed Live Loads provided at the base of all
footings and retaining walls which will have earth placed against them. Washed drain rock
· Joist Hangers: LUS/LU/U/HU/HUC, JB, HUTF/HUSTF (top-flange)
· Wood I-Joists: Used extensively in floor and roof framing (Trus Joist TJI's
typically specified)
must extend to within one
foot of finished grade. Footing drains shall be 4†perforated pipe routed down gradient to · Laminated Veneer Lumber (LVL): Minimum modulus of elasticity E = 2.0x10^6
psi · I-Joist Hangers: IUS/MIU, ITS/MIT/HIT (top-flange)
1
daylight, unless otherwise
specified.
DEFLECTION LIMITS
· Parallel Strand Lumber (PSL): Minimum modulus of elasticity E = 2.0x10^6 psi
· Beam Hangers: HU/HUC/HUCQ/HGUS, LEG/MEG/EG (top-flange)
VERSION
Concrete: Mix and 28 day strength
unless noted otherwise: · Laminated Strand Lumber (LSL): Minimum modulus of elasticity E = 2.0x10^6 psi
· Rafter Hangers: LSU/LSSR/LSSJ, LRUZ
STRUCTURAL MEMBER LIVE SNOW LIVE+DEAD · Concrete compressive
strength, f'c = 3,000 psi Multi-ply LVL's: Where multi-ply LVL beams are specified on the structural drawings,
provide LVL connection per ·
Truss and Rafter Connection: H1, H2.5A, or SDWC15600 at each heel to double plate
1 D
Roof (with sheetrock ceiling) L/360 L/360 L/240 · Required f'c shall be
evaluated at 28 days (56 days OK for fly ash or slag) International Beams' Technical Bulletin TB-LVL-2
VER. SIZE
· Holdowns: HDU/DTT with SSTB, STHD14, STHD14RJ Floor-to-floor Strap-Ties: HDU2, MST48
Wood Structural Panels: American Plywood Association (APA) rated sheathing is
required for all wood structural
Roof (without sheetrock ceiling) L/240 L/240 L/180 · Concrete exposed to
weather shall have air entrainment of 6% (+/-1.5%)
Fastener Requirements: The number and size of fasteners connecting wood members shall not be less than that
panels. Unless noted otherwise, the wood panel for each situation is:
· Maximum water / cement
ratio = 0.45
set forth in IBC Table 2304.10.1.
Roof (not supporting ceiling) L/180 L/180 L/120
· Roof Sheathing: 1/2" CDX (plywood with moisture resistant glue - highly recommended),
CD (plywood), or
· 25% max fly ash... 50%
max slag 7/16" OSB (oriented strand board), with ply clips or T&G (tongue and groove).
Nail with 10d nails at 6" O.C. Exposure: Any hardware or fasteners exposed to the elements shall be heavy duty galvanized or stainless steel.
Floor Members L/360 - L/240
Lifts: Lifts shall be poured
within 60 minutes of the previous lift along edges, 12" O.C. in the field, no blocking required
Horizontal Deflection (any case) L/240 - - Temperature: Pour concrete
at outdoor temperatures of 40 degrees and above. · Prescriptive Exterior Wall Sheathing: 7/16" OSB or 15/32" CD ply, 8d nails
at 6" O.C. along edges, 12" O.C. in INSPECTIONS
4/24/2022L. SCHWEIGERTD. BRADLEYD. BRADLEYAS NOTED
the field, no blocking required. All exterior walls to be sheathed per prescriptive
requirements noted above
Farm Buildings & Greenhouses - - L/180 Reinforced Concrete: Place
all reinforcing per plans, details, and applicable code requirements. Lap all continuous
DATE ENGINEERED BYCHECKED BYAPPROVED BYSCALE
bars 48 X bar diameter minimum.
For a typical continuous #4 bar (diameter = 0.5") the rebar lap is equal to 48 X 0.5" unless explicitly noted as a shearwall
Inspections: Construction or work for which a building permit is required is subject to inspection by the building
The above maximum deflection limits are required by 2015 IBC Table 1604.3. Higher deflection = 24" minimum. Reinforcing
bars, bolts, anchors, etc shall be securely tied in position prior to concrete placement. · Prescriptive Interior Wall Sheathing: 1/2" Drywall (Gypsum Wall Board - GWB),
screwed with 1-1/4" Type W or official. Such construction shall remain exposed and accessible for inspection purposes until approved (IBC 110).
values may be used at the engineer's discretion to improve structural performance Reinforcing steel shall be
free of rust and coatings. S screws at 7" O.C. along edges, 7" O.C. in the field
Statement of Special Inspection:
Anchor Bolts: Provide 5/8"
diameter x 10" long wet-set or expansion anchor bolts @ 4' O.C. and within 6-12" of · Floor Sheathing: 3/4" CD or OSB, nailed with 8d nails at 6" O.C. along edges,
12" O.C. in the field. glued with
REFERENCE CODES & STANDARDS corners with 3"x3"x0.229"
square washers. 7" minimum anchor bolt embedment required. construction adhesive prior to nailing, no blocking required (unless noted
otherwise) 1. Special inspections and structural testing shall be provided by an independent agency employed by the
Owner for the items identified in this statement of the approved construction dosuments and specifications, unless
Adhesive Anchors: Unless noted
otherwise, epoxy anchors in concrete with Simpson SET-XP or Hilti HIT-HY 200-R or Stairs: Refer to IBC 1011 for stairway requirements.
· International Building Code, IBC 2018
waived by the Building Official (IBC Chapter 17).
equivalent epoxy, installed
per manufacturer's guidelines. For extreme temperature applications, when long-term Studs at Opening: Min (1) jack and (1) king stud required at each end of an opening
unless otherwise noted.
· Washington State Building Code, SBC 2018 temperature exceeds 110°F
or is less than 0°F, use Simpson Set-3G.
Exterior Stud Walls: Use 2x6 studs @ 16" O.C. unless noted otherwise. 2x6 exterior
stud walls are typically 2. Special inspections, statements of special inspections, responsibilities of Contractors, submittals to the
· National Design Specification for Wood Construction, NDS 2018 Waterproofing: Waterproof
all basement walls and slabs on grade. It is highly recommended to use asphalt desirable for insulation/energy code reasons (i.e. not structural reasons).
Building Official, and structural observations shall meet the requirements of IBC 1704.
· Wood Frame Construction Manual, WFCM 2018 waterproofing sealer or Eucon
Vandex AM-10 crystalline admixture. These waterproofing agents shall be installed per Interior Walls: Minimum 2x4 studs @ 16" O.C., unless required for plumbing/utility
reasons
· Building Code Requirements for Structural Concrete, ACI 318-19, the manufacturer's recommendations.
At cold-joints, water-stops are highly recommended.
3. The names and credentials of the Special Inspector(s) shall be submitted to the Building Official. The Special
Engineering
Wood Stud Holes & Notching: For wood studs 12' and less, it is permissible to
cut notches and holes per the
· Minimum Design Loads for Buildings And Other Structures, ASCE 7-16
following requirements. Notch/hole size shall not exceed the following max percentage
of stud width: Inspector shall be certified under the WABO Special Inspection Certification Program. The inspector shall
demonstrate competency per IBC 1704.2.1.
· Steel Construction Manual, 15th Edition, AISC 2015 SLAB ON GRADE
· Bearing walls: Hole - 40% of total stud width, Notch - 25% of total stud
width
· Non-bearing walls: Hole - 60% of total stud width, Notch - 40% of total stud
width 4. Duties of the Special Inspector:
Control Joints: Control joints
(expansion, cold, or saw-cut) at 8'-12' O.C. required to mitigate shrinkage cracking.
GENERAL REQUIREMENTS
· In all cases, hole edges must be at least 5/8" from edge of the stud
Rebar or woven wire mesh (if
installed) shall break at all control joints. Saw-cut joints within 12 hours of pour.
a. The Special Inspector shall review all work listed for conformance with the approved construction plans and
· OK to drill up to 1" diameter hole for studs up to 16' tall. Hole to be
5/8" from edge of stud.
Codes: All materials and work shall adhere to the minimum requirements of the Reference Codes & Standards Slabs on Grade: Unless noted
otherwise, garage slab shall be 4" concrete slab with fiber mesh or #3 rebar at 24" O.C.
the 2015 IBC.
listed above. Contractor shall be responsible to comply with OSHA, State Labor, and Industry Standards. each way or 6x6xW1.4 woven
wire mesh, over 10 mil poly vapor barrier over 4" compacted crushed rock.
Bradley
Contractor assumes full responsibility of construction methods used, safety provisions employed, and the W1.4
DECKS & BALCONIES
b. The Special Inspector shall furnish special inspection reports to the EOR, Contractor, Owner and Building
Reinforcing: Reinforcing bars
or woven wire mesh shall be as noted on plans and shall be placed 1-1/2" above the
Official on a weekly basis or as required by the Building Official. All items not in compliance shall be brought to
finished condition of the structure.
bottom of the slab.
Railings: Unless noted otherwise and detailed, guardrails to meet IBC 1015. Guardrails
shall be 48" high min with the attention of the Contractor for correction, and if uncorrected, to the EOR and the Building Official.
Construction Personnel: Only competent personnel familiar with construction and safety practices relevant to the Curing: Use water or membrane
cure immediately after initial set for a minimum of 7 days. For water cure, hose it max opening size so that a 4" sphere cannot pass through. Guardrails shall be designed
to withstand a 200 lb point
project should be employed to assemble and construct the work. down and keep it wet. For
membrane curing, wet the concrete then cover with an impermeable membrane (e.g. load applied in any direction and at any location on the top rail and shall be
designed to withstand a uniform load of c. Once corrections have been made by the Contractor, the Special Inspector shall submit a final signed report
Construction Methods and Project Safety: The project drawings and specifications represent the finished visqueen) or liquid membrane
curing compound. Provide shade for concrete during curing. 50 lb/ft applied horizontally to the top rail. Contractor/owner/inspector to physically
verify (e.g. push & pull on top to the Building Official stating that the work requiring special inspection was, to the best of the Special Inspector's
structure and do not indicate methods, procedures, or sequence of construction. The builder must take Drainage: Garage slabs, porch
slabs, and other concrete surfaces that are required to drain shall be sloped between rail) that the guardrails meet the IBC loading requirements mentioned above.
knowledge, in conformance with the construction documents and the provisions of the 2015 IBC.
necessary precautions to maintain and ensure the integrity of the structure during construction. Bradley 1/8" and 1/4" per 1'.
Waterproofing: Bradley Engineering is not responsible for adequacy of waterproof
membranes on decks which 5. Duties and responsibilities of the Contractor:
Engineering, Inc. will not enforce safety measures or regulations, nor will the owner or designer. Therefore, the
cover living space.
Concrete Topping: Concrete
topping can not be installed on floors unless specifically detailed on the structural
a. The Contractor shall submit a written statement of responsibility to the Owner and the Building Official prior
contractor shall design, construct, and maintain all safety devices and follow all pertinent regulations.
drawings. The concrete topping
shall be installed per manufacturer's specifications.
to the commencement of work. In accordance with IBC 1704.4, the statement of responsibility shall
Temporary Support: The builder must provide adequate temporary support to all walls, roofs, beams, and floors Non-Bearing Interior Wall
to Slab Connection: Interior walls shall be connected to concrete slab with minimum STAIRWAYS
acknowledge the special inspection requirements contained within this “Statement of Special Inspectionsâ€.
during construction. Design of these supports are not included unless specifically shown. Contractor is 1/2"x5-1/2" long anchor bolts
@ 6' O.C.. Wet-set, epoxied, expansion, or screwed (i.e. Simpson Titen HD) anchor
Stairs: Refer to IBC 1011 for stairway requirements.
responsible for the adequacy of all temporary support systems. bolts are acceptable. If interior
wall is not specifically denoted as a shear wall, it is acceptable to use 3/8"x5" Titen
b. The Contractor shall notify the responsible Special Inspector that work is ready for inspection at least one
(360) 510-9514
screws @ 48" O.C. (i.e. Simpson
THD375000H or equivalent) Handrails: Unless noted otherwise and detailed, handrails to meet requirements of IBC
1014. working day (24 hours minimum) before such inspection is required.
Specifications: All notes, call-outs, and details included within this design package are required unless
specifically noted otherwise.
c. All work requiring special inspection shall remain accessible and exposed until it has been observed by the
ROOFS
Verification: Verify all dimensions, elevations, and site conditions before starting work.
Special Inspector.
CRAWL SPACE
Errors: The contractor is responsible to check the plans and site conditions and to notify the
Manufactured Trusses: Unless stick framing is specified on structural drawings,
wood trusses are to be engineered
LUKE
6. Please see the 'Special Inspection Schedule' below for the types and extents of special inspections and tests
architect/designer/engineer/owner of any errors or omissions prior to the start of construction. Vapor Barrier: Cover entire
crawl space with class I vapor retardant (i.e. poly vapor barrier - 6 mil required, 10 mil by a truss manufacturer. If truss layout is not provided by truss manufacturer,
the engineer assumes that trusses all
directly related to the structural engineering aspects of this project. Special inspections and tests shall meet the
highly recommended). Extend
6" up foundation walls minimum. bear on exterior walls and do not bear on interior walls. Trusses and
truss connections/hard-ware to be in
Conflicts: Notes and details on the structural drawings take precedence over the Standard Structural
accordance with truss manufacturer's requirements. Do not modify or
cut trusses without approval of truss applicable requirements of IBC 1705. Architectural special inspections (e.g. Water Intrusion Per RCW 64.55) have
luke@bradleyengineeringinc.com
Specifications and typical details. Written dimensions take precedence over scaled drawing dimensions. Access: Provide min 18"x24"
crawlspace access per IBC 1208.1.
not been included in the following table and are not under the purview of the engineer of record.
manufacturer.
Structural notes and details on the structural drawings take precedence over the architectural drawings. Foundation Ventilation: Ventilation
per IBC 1202.4. Minimum 1 square foot of ventilation per 150 square feet of crawl
space. Space vents evenly
to provide cross ventilation. Cover with 1/8" corrosion resistant mesh screen. Girder Trusses: Truss manufacturer to be responsible for placement of girder trusses.
Install girder truss LGT tie
Changes: Written approval from the engineer of record is required for any structural changes to the provided
down or SDWC15600 screws to secure girder trusses as detailed on structural
drawings. Number of studs SPECIAL INSPECTION SCHEDULE - STRUCTURAL ONLY
drawings. Changes may be made 'in the field' with consent of Bradley Engineering. Please provide a red-lined
supporting girder truss to match plies of girder (e.g. 3-ply girder truss to bear
on minimum 3 studs).
drawing or sketch of desired change(s) to provide context and applicable information prior to contacting
Material Structural Component Req'd? Code Reference Notes
BRADLEY ENGINEERINGWWW.BRADLEYENGINEERINGINC.COMDAVID BRADLEY, P.E.811 YEW STREET // BELLINGHAM, WA 98229(360) 752-5795DAVID@BRADLEYENGINEERINGINC.COMFOR QUESTIONS & CHANGES
PERTAINING TO THISPROJECT, CALL ATOR EMAIL
engineer. Please contact the engineer who performed the engineering for your project as noted on this drawing. ALLOWABLE
HOLES - I-Joists & I-Rafters Lateral Bracing: Contractor to install lateral bracing in roof as specified by truss
manufacturer. (Y/N)
The engineering for this project was completed by Luke Schweigert whose phone number is (360) 510-9514.
Headers: Unless noted otherwise, all bearing wall headers to be 4X10 or 6X8 D.F.2
min Structural Steel N IBC 1705.2.1 Inspect per AISC 360
Minimum distance
from hole to support. See Table A below Up to 1-1/2" hole may be cut anywhere
Cold formed steel deck N IBC 1705.2.2 Inspect per SDI QA/QC
Substitutions: If connector or lumber product substitutions are desired, contractor shall provide manufacturer's
out-side of hatched zone. For holes larger Over-framing: Unless noted otherwise over-framing to be 2X6 @ 24" O.C. Overframing
to be bear directly on top Steel Open web steel joists and girders N IBC 1705.2.3 Inspect per Table 1705.2.3
evaluation reports of proposed substitutions to the engineer/owner for approval.
No holes in than 1-1/2" diameter, refer to Table A of truss below. See rafter span chart below for max spans. Manufactured truss
overframing is acceptable.
flange of I-Joist
Verify truss bracing and attachment
Cold formed steel trusses > 60' span N IBC 1705.2.4
Member Size: The member dimensions (e.g. depth and width of beams, columns, etc.) specified in these
Access: Attic access shall be provided per IBC 12.09.2. The rough framed opening
size shall not be less than per truss submittal package
drawings are structural minimums. It is acceptable to increase the size above what is specified.
22"X30" and shall be located in a hallway or other readily accessible location.
Concrete Concrete Y IBC 1705.3 Inspect per Table 1705.3
6"
6"
Masonry Masonry N IBC 1705.4 Inspect per TMS602 / ACI530.1
Similar work: Where construction details are not shown or noted for any part of the project, the area shall be
Inspect sheathing, fasteners, fastener
constructed in the same manner as similar work shown on the drawings. 6"
L1 2 x D1 D1 Closely grouped round L2 2 x L2 D2 6" 6"
High-load diaphragms N IBC 1705.5.1
No holes
in minimum holes are allowable if the minimum
spacing, etc. per structural drawings
Modification of Structural Members: Cuts, notches, and holes bored in trusses, structural composite lumber, hatched
zones group meets requirements
Wood Verify truss bracing and attachment
glue-laminated members, or I-joists are prohibited except where permitted by the manufacturer's
for round or square holes
Wood trusses > 60' span N IBC 1705.5.2
per truss submittal package
recommendations or as shown on this page. (See ALLOWABLE HOLES) Table
A - Minimum Hole Distance From Support
Existing soil conditions and fill
TJI Rating ** ROUND HOLE SIZE RECTANGULAR HOLE SIZE
Soils material and placement Y IBC 1705.6 Inspect per Table 1705.6
Scope of Work: The scope of work of Bradley Engineering, Inc. is limited to the structural engineering and JOIST
analysis pertaining to the subject structure. Bradley Engineering, Inc. takes no responsibility for items not DEPTH
(Flange Width) 2" 3" 4" 2" 3" 4" ALLOWABLE HOLES - Solid or Eng. Lumber
Inspect per Table 1705.7, geotech.
Driven Deep
Driven deep foundations N IBC 1705.7
specifically addressed in the drawings, calculations, or call-outs.
210 (2-1/16") 1'-0" 1'-6" 2'-0" 1'-0" 1'-6" 2'-6"
Foundations report and constr. documents
117 "
8
360 (2-5/16") 1'-6" 2'-0" 3'-0" 1'-6" 2'-6" 3'-6"
Cast-in-place Inspect per Table 1705.8, geotech.
Completion of Work: Submittal of these structural drawings to the client completes the present scope of work
210 (2-1/16") 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 2'-0" No holes in 8X diameter of the
Ok to completely Cast-in-place deep foundation N IBC 1705.8
14"
Deep Foundation report and constr. documents
and budget of Bradley Engineering, Inc. Other consultation, design, calculations, sketches, inspection, etc. after
360 (2-5/16") 1'-0" 1'-0" 1'-6" 1'-0" 1'-6" 2'-6" hatched areas largest hole (min) Allowable remove
this area
submittal of this report shall be billed on an hourly basis. 16"
210 (2-1/16") 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" L/8 8X Ø hole zone
L/8 Helical Pile Helical Pile Foundation N IBC 1705.9 Inspect per Table 1705.9, geotech.
360 (2-5/16") 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-6"
Foundation report and constr. documents
D/4
Fabricated Items Fabricated Items N IBC 1705.10 Inspect per Section 1704.2.5
DO NOT,
under any circumstances, cut or notch joist flanges (don't even think about it) D/2
D/2
Leave
1 " of web (minimum) at top and bottom of hole (i.e. do not cut within 1/8" of flange ) D D/2
Structural Wood Y IBC 1705.11.1 Inspect per Section 1705.11.1
STRUCTURAL STEEL 8
Wind Resistance Cold-formed light-frame steel N IBC 1705.11.2 Inspect per Section 1705.11.2
Round
or rectangular holes allowed according to Table A
Grade: Unless noted otherwise, the grade of steel members is as follows:
D/4
1-1/2"
max hole size in cantilever
Structural steel N IBC 1705.12.1 Inspect steel per AISC 341
· Wide flange (W).................................................. ASTM A992 Steel Fy = 50 ksi Fu = 65 ksi Ok to
cut web in a similar fashion for any manufacturer's I-Joists. For Table A, Use Flange Width instead of TJI Rating L/4 L/2
L/4
May want
to refer to joist manufacturer's specifications and requirements
L
Inspect sheathing, fasteners, fastener
· HSS Tube (HSS)................................................. ASTM A500, Grade B or better. Fy = 46 ksi Fu = 58 ksi
Hole Size: The hole diameter should not exceed
2" Structural wood Y IBC 1705.12.2 spacing, hold-downs, etc. per
· Channels, plates, angles..................................... ASTM A36, Fy = 36 ksi Fu = 58 ksi.
or 1/10 the beam depth, whichever is smaller.
approved construction documents
· Bolts ................................................................... ASTM A325 or better
JOIST CONVERSION CHART
Cold-formed light-frame steel N IBC 1705.12.3 Inspect per Section 1705.12.3
· These guidelines are applicable to glued-laminated, solid sawn,
and engineered Inspector to verify accordance with
· Anchor bolts ....................................................... ASTM F1554 or better Trus Joist Pacific
Woodtech Boise Cascade Roseburg Red Built LP
Seismic Resistance Designated seismic systems N IBC 1705.12.4
lumber (beams, headers, joists, rafters, etc)
ASCE 7 Section 13.2.2
· #4 Rebar & Smaller ............................................ Grade 40 (Fy = 40 ksi or better) THICKER TJI 210
PWI 47 BCI 6000 RFPI 40 Red-I 45 LPI 530 · Uniform loads only, no point loads
Architectural components N IBC 1705.12.5 Inspect per Section 1705.12.5
· #5 Rebar & Larger .............................................. Grade 60 (Fy = 60 ksi or better) FLANGE TJI 360
PWI 70 BCI 60 RFPI 70 LPI 36 · Round holes only
Plumbing, mechanical, and
N IBC 1705.12.6 Inspect per Section 1705.12.6
WIDTH
PWI 77 RFPI 700 Red-I 65 · No holes in cantilevers
electrical components
Connections: Unless noted otherwise, steel to steel connections to be 1/4" continuous fillet weld. All structural
GENERAL STRUTURAL REQUIREMENTSPAISLEY LOFTS105 E. DIVISION STREETARLINGTON, WA
steel to be fabricated in accordance with the AISC manual of steel construction, latest edition. TJI 560
PWI 90 BCI 90 RFPI 90 Red-I 90 LPI 56 · DO NOT cut, notch, or drill holes in headers or beams except as
indicated in sketch Storage racks N IBC 1705.12.7 Inspect per Section 1705.12.7
Seismic isolation systems N IBC 1705.12.8 Inspect per Section 1705.12.8
Welding: Steel welding to be done using E70 electrodes, and conform to AWS D1.1, latest edition. OK to substitute the
joists specified on drawings (TJI's) with joists listed in this table. Match the original
Cold formed steel moment frames N IBC 1705.12.9 Inspect per Section 1705.12.9
Washers: Provide standard washers under all nuts and anchor bolts depth and spacing.
OK to use thicker flange width than specified (e.g. use TJI 360 instead of TJI 210)
S11 of 11
DRAWING TO BE PRINTED ON 24"X36" IN ORDER TO BE SCALE