Loading...
HomeMy WebLinkAbout17216 51st Ave Ne Ste 110_BLD6263_2025 COMMERCIAL MECHANICAL APPLICATION Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping and must be accompanied by ELECTRONIC CONSTRUCTION DRAWINGS and CUT SHEETS and/or information outlined in the MECHANICAL SUBMITTAL REQUIREMENTS, if applicable. Type of Permit:  New Installation  Addition  Alteration  Replaced  Gas Piping Type I and Type II Hood Systems required submittal of the Commercial Mechanical Addenda Property Address: Project Valuation: Lot #: Parcel ID No.: Preferred Contact:  Owner  Contractor Project Description: Owner Name: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Contractor Name: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured per IFGS, Section 415 • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 3  Not Applicable  CSST Brass Other Proposed Piping Material: Black Steel Galvanized Steel Proposed Piping Size: ½”  ⅝”  ¾”  1”  1½”  2” Inlet Pressure: Pressure Drop: Specific Gravity: I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulation of the State of Washington. Signature Print Name Date REV03.2022 Page 1 of 3 MECHANICAL PERMIT FEES (per unit) Type of Fixture No. of Units Cost per Unit Subtotal Additional Plan Review fees x $ 75.00 = $ Air Conditioning Unit ≤ 100 Btu/h x $ 15.00 = $ Air Conditioning Unit > 100 Btu/h x $ 25.00 = $ Air Conditioning Unit > 500 Btu/hp x $ 50.00 = $ Air Handling Units x $ 15.00 = $ Base Mechanical Fee $ 25.00 $ 25.00 Boiler <100Btu/h >3hp x $ 15.00 = $ Boiler >1 million Btu/h<50hp x $ 25.00 = $ Boiler >1.5 million Btu/h<50hp x $ 50.00 = $ Boiler >100Btu/h 3-15hp x $ 15.00 = $ Boiler >500Btu/h 15-30hp x $ 25.00 = $ Commercial Hoods -Type I x $ 25.00 = $ Commercial Hoods -Type II x $ 50.00 = $ Diffusers x $ 15.00 = $ Dryer Ducting x $ 15.00 = $ Ductwork (drawings required) x $ 25.00 = $ Evaporative Coolers x $ 15.00 = $ Exhaust/Ventilation Fans x $ 15.00 = $ Fireplace/Insert/Stove x $ 15.00 = $ Forced Air Heat ≤100 Btu/h x $ 15.00 = $ Forced Air Heat >100 Btu/h x $ 25.00 = $ Gas Clothes Dryer x $ 15.00 = $ Gas Fired Air Conditioning Unit ≤ 100 Btu/h x $ 15.00 = $ Gas Fired Air Conditioning Unit > 100 Btu/h x $ 25.00 = $ Gas Fired Air Conditioning Unit > 500 Btu/hp x $ 50.00 = $ Gas Piping ≤ 5 units x $ 15.00 = $ Gas Piping for each additional unit > 5 x $ 2.00 = $ Heat Exchangers x $ 15.00 = $ Heat Pump-Condensing Unit x $ 25.00 = $ Hot Water Heat Coils x $ 15.00 = $ Miscellaneous Appliance - regulated by $ 15.00 $ x = mechanical code, not otherwise specified Package Units ≤ 100 Btu / > 100 Btu x $ 25.00/$50.00 = $ Range/Cook top-Gas Fired x $ 15.00 = $ Refrigeration Unit ≤100Btu/h x $ 15.00 = $ Refrigeration Unit >100Btu/h x $ 25.00 = $ Refrigeration Unit >500Btu/h x $ 50.00 = $ Re-inspection fee (all) x $ 75.00 = $ Unit Heaters ≤ 100 Btu/h x $ 15.00 = $ Unit Heaters >100 Btu/h x $ 25.00 = $ Variable Air Volume Boxes (part of Air $ 10.00 $ x = Conditioning System) Wall Heaters - Gas Fired x $ 25.00 = $ Water Heater - Gas Fired x $ 25.00 = $ Permit Fee $ Table 4-8; Plan Review Fee $ Processing/Technology Fee $25.00 Total $ REV2.2024 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY  SCHEMATIC IS TO SCALE  SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated REV2.2024 Page 3 of 3 ABBREVIATIONS PLAN SYMBOLS GENERAL HVAC NOTES G A Ø DIAMETER N W CEILING SUPPLY DIFFUSER 1. COMPLETE INSTALLATION OF MECHANICAL SYSTEMS SHALL MEET APPLICABLE CODES PER 2018 IBC, 2018 EI , AFF ABOVE FINISHED FLOOR E AHU AIR HANDLING UNIT WASHINGTON STATE MECHANICAL CODE, & 2018 WASHINGTON STATE ENERGY CODE. L O BHP BRAKE HORSEPOWER CEILING RETURN GRILLE 2. VENTILATION BY MECHANICAL OR NATURAL MEANS SHALL BE NO GREATER THAN 150 PERCENT OF THE O RN BDD BACKDRAFT DAMPER MINIMUM OA REQUIRED PER WSEC C403.2.2. O BPD BY-PASS DAMPER O BTU/H BRITISH THERMAL UNIT PER HOUR CEILING EXHAUST GRILLE 3. All EQUIPMENT SPECIFIED THE SMALLEST SIZE THAT EXCEEDS THE CALCULATED LOADS PER WSEC area of work IS M C CONDENSATE DRAIN PIPING C CD CEILING DIFFUSER C403.3.1. CFM CUBIC FEET PER MINUTE FLEX DUCT AHU-1 (18K)TO ROOF. EF-2 TO NEAREST CONDENSATE 1 4. SYSTEM CONTROLS TO MEET ALL APPLICABLE SECTIONS UNDER SEC C403.4 OF 2018 WSEC. T DRAIN.. C& DB DECIBAL NOT IN SCOPE 2 S S S DH DUCT HEATER CEILING EXHAUST FAN 5. THERMOSTATS SHALL BE SET TO MAINTAIN A MINIMUM DEADBAND OF 5°F PER WSEC C403.4.1.2. 2 2 DOAS DEDICATED OUTDOOR AIR SYSTEM 6. CONTROLS TO BE EQUIPPED WITH AUTOMATIC TIME CLOCK CAPABLE OF STARTING AND STOPPING THE G 55 EER ENERGY EFFICIENCY RATIO 3 3 E 4 INLINE EXHAUST FAN MD MD N IAH-1 IAH-2 EG EXHAUST GRILLE SYSTEM WITH MANUAL OVERRIDE PER WSEC C403.4.2.2. (ON ROOF) (ON ROOF) I 1 ESP EXTERNAL STATIC PRESSURE MD MD EF-1 EF-4 7. ALL ECONOMIZERS PROVIDED SHALL MEET SEC C403.5 OF 2018 WSEC AND BE ABLE TO PROVIDE UP TO (ON ROOF) (ON ROOF) 84' 41'-8" EXH EXHAUST 41'-8" X EXHAUST FAN UP CF-1 CF-2 T O 100 PERCENT OSA FOR COOLING PER WSEC C403.5.3.1. FCU FAN COIL UNIT R 4 T B S S A 2 FD FIRE DAMPER 8. OUTDOOR AIR SUPPLY, EXHAUST OPENING, RELIEFS TO BE PROVIDED WITH CLASS 1 MOTORIZED DAMPER 2 . FPM FEET PER MINUTE ROUND DUCT UP E EF-2 (ON ROOF) FSD FIRE AND SMOKE DAMPER AND CLOSE DURING UNOCCUPIED EQUIPMENT OPERATION PER WSEC C403.7.8.1. IF GRAVITY DAMPER, IT MD MD .O EF-3 (ON ROOF) A A M1.0 M1.0 PH P GF GAS FURNACE SHALL HAVE AN AIR LEAKAGE RATE NOT GREATER THAN 20 CFM/FT^2. ROUND DUCT DOWN GRD GRILLE, REGISTER, DIFFUSER 2 2 9. SMOKE DETECTORS INSTALLED IN MAIN RETURN PER SEC 606 OF THE 2018 IMC. S S HP HORSEPOWER, HEAT PUMP HRU HEAT RECOVERY UNIT VAV FAN BOX 10. DUCTS TO BE SUPPORTED AT EACH CHANGE IN DIRECTION, VERTICAL AT 12'-0" MAX, HORIZONTAL AT 10'-0" HVAC HEATING VENTILATION & AIR CONDITIONING MAX WITH STRAP, OR 8'-0" MAX FROM TRAPEZE SUPPORT ID INSIDE DIMENSION BALANCE DAMPER (MANUAL) 11. DUCT INSULATION AND SEALING TO MEET REQUIREMENTS OF SEC C403.10.1 OF THE 2018 WSEC. IECC INTERNATIONAL ENERGY CONSERVATION CODE IFR INFRARED HEATER 12. ALL PIPING TO BE INSULATED ACCORDING TO SECTION C403.10.3 OF 2018 WSEC. IMC INTERNATIONAL MECHANICAL CODE GD GRAVITY DAMPER IN INCH 13. GAS PIPING TO BE INSTALLED IN ACCORDANCE WITH THE 2018 IFGC TABLE C404.6 WHEN APPLICABLE. ISP INTERNAL STATIC PRESSURE FSD FIRE SMOKE DAMPER 14. FLEXIBLE INSULATED DUCTS SHALL BE MAXIMUM 5'0" LONG AND STALL MEET INSTALLATION AND LB POUND LVR LOUVER MATERIAL REQUIREMENTS OF LOCAL CODES. MCA MINIMUM CIRCUIT AMPACITY M MOTORIZED DAMPER 15. 2018 SMC SECTION 603.4 METALLIC DUCTS. METALLIC DUCTS SHALL BE CONSTRUCTED AS SPECIFIED IN MAN/D MANUAL DAMPER THE SMACNA HVAC DUCT CONSTRUCTION STANDARDS—METAL AND FLEXIBLE. MECH MECHANICAL MIN MINIMUM ZONE DAMPER 16. 603.6.1 FLEXIBLE AIR DUCTS. FLEXIBLE AIR DUCTS, BOTH METALLIC AND NONMETALLIC, SHALL BE TESTED MOCP MAXIMUM OVERCURRENT PROTECTION MO/D MOTORIZED DAMPER IN ACCORDANCE WITH UL 181. SUCH DUCTS SHALL BE LISTED AND LABELED AS CLASS 0 OR CLASS 1 N SITE PLAN VICINITY MAP FIRE DAMPER ABOVE DIFFUSER N NC NOISE CRITERIA FLEXIBLE AIR DUCTS AND SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 304.1. NOM NOMINAL NO. NUMBER 17. ALL SUPPLY GRILLES TO HAVE MANUAL VOLUME DAMPERS FOR BALANCING OF SYSTEM UPON NTS NOT TO SCALE FIRE DAMPER ABOVE GRILLE COMPLETION. OA OUTSIDE AIR AIR VOLUME REFERENCE PROPERTY DETAILS SHEET INDEX OBD OPPOSED BLADE DAMPER T THERMOSTAT 18. HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF 408 IN 2018 WSEC HAVE BEEN ODD OUTSIDE DIMENSION OF DIAMETER SATISFIED, INCLUDING AS-BUILT DRAWINGS, SUBMITTALS, O&M MANUALS, BALANCE REPORT, AND ODU OUTDOOR UNIT 6" Ø - 0 TO 90 CFM TENANT: TENANT 48 M0.0 HVAC GENERAL NOTES S SENSOR COMMISSIONING REPORT. POC POINT OF CONNECTION 8" Ø - 90 TO 180 CFM PSI POUNDS PER SQUARE INCH 19. ALL HVAC EQUIPMENT TO BE LABELED FOR THE SPACE SERVED. M1.0 FIRST FLOOR MECHANICAL PLAN M GAS METER 10"Ø - 180 TO 350 CFM LAND OWNER: CITY OF ARLINGTON R REFRIGERATION LINES 20. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON SITE FOR INSPECTORS. M2.0 ROOF MECHANICAL PLAN RA RETURN AIR 12"Ø - 350 TO 550 CFM RCP REFLECTED CEILING PLAN SM 21. MEP DRAWINGS ARE NOT STRUCTURAL ENGINEERING DRAWINGS. WHERE STRUCTUREAL ENGINEERING IS RG RETURN GRILLE SMOKE DETECTOR REQUIRED, IT WILL BE BY OTHERS. 14"Ø - 550 TO 850 CFM PARCEL NO. 31052100400300 RPM REVOLUTIONS PER MINUTE RTU ROOFTOP UNIT 16"Ø - 850 TO 1350 CFM SD-# SUPPLY DIFFUSER SD SUPPLY DIFFUSER 18"Ø - 1350 TO 1750 CFM PROPERTY DESCRIPTION: SL SOUND LINED SP STATIC PRESSURE RG-# RETURN GRILLE SECTION 21 TOWNSHIP 31 RANGE 05 QUARTER SE LOT B CITY ARL BSP PLN#942 REC AFN SM/D SMOKE DAMPER P-TRAP DETAIL *USE ABOVE UNLESS OTHER SIZE IS 202206075002 BEING A PTN SE1/4 SE1/4 SD SEC LESS BLDGS ONLY ON 31052100400301 TG TRANSFER GRILLE TSTAT THERMOSTAT EF-# EXHAUST FAN INDICATED ON PLANS 3/4" CAP for cleanout TYP TYPICAL (DO NOT GLUE) VAV VARIABLE AIR VOLUME TG-# SITE AREA: 8.16 ACRES BUILDING AREA: 168,494 SF source elevation level TRANSFER GRILLE 3/4" CONDENSATE pipe VFD VARIABLE FREQUENCY DRIVE 3/4" OPEN PIPE ABOVE VTR VENT TO ROOF UNION TEE source elevation level USE CODE: 637 WAREHOUSING & STORAGE SERVICES WSEC WASHINGTON STATE ENERGY CODE - C - CONDENSATE LINE TO DRAIN ZD ZONE DAMPER 1" min. - R - REFRIDGERATION LINES SCOPE OF WORK: EQUIPMENT TEE 3" MIN. or 1. PROVIDE AND INSTALL 1 2 TR. WALL MOUNTED UNIT FOR EXISTING SERVER ROOM. mnfr req. 2. PROVIDE AND INSTALL 4 EXHAUST FANS AND 4 OUTDOOR AIR INTAKE HOODS. trap drain must be lower than source 3. PROVIDE AND INSTALL 2 CEILING FANS. 2" MIN. indoor UNIT SCHEDULE IDENTIFIER PERFORMANCE ELECTRICAL SPECIFICATIONS CAPACITY (BTU/H) design REFER SIZES SOUND DIMENSIONS TAG MAKE MODEL POWER SUPPLY MCA (A) WEIGHT NOTES cooling airflow (LIQUID/SUCTION) DBA ( W X H X D) AHU-1 carrier 40mahbq24xa3 24000 611 3/8 / 5/8 44 208/230-1-60 .625 44.88 X 14.57 X 10.83 43 .65 LBS 1. NONE OUTDOOR HEAT PUMP / CONDENSER SCHEDULE IDENTIFIER PERFORMANCE ELECTRICAL CAPACITY REFER SIZES SOUND POWER MCA / MOCP DIMENSIONS (IN) TAG MAKE MODEL REFER TYPE WEIGHT NOTES (BTU/H) (LIQUID/SUCTION) DBA SUPPLY (A) (W X H X D) HP-1 CARRIER 38MARBQ24AA3 24000 R-410A 3/8 / 5/8 62 208/230-1-60 25 / 35 37.24 X 31.89 X 16.14 134.48 LBS exhaust fan SCHEDULE IDENTIFIER PERFORMANCE ELECTRICAL specifications TENANT 48 2.017216 51ST AVENUE NE ARLINGTON, WA 98223 external INSTALL design SOUND POWER DIMENSIONS APPROX. TAG MAKE MODEL static MCA / MOPD NOTES LOCATION cfm (sones) SUPPLY (Ø X H) WEIGHT pressure ef-1,2,3,4 GREEN HECK GB-330-VG-50 ROOF 15000 .4 25 460/60/3 9/ 20 58.8 X 50.5 385 1,2 1. FAN opertaion TO BE CONTROLLED BY co/no SENSORS. 2. provide motorized damper. CEILING fan SCHEDULE IDENTIFIER PERFORMANCE ELECTRICAL specifications external INSTALL design SOUND POWER MOTOR SIZE DIMENSIONS APPROX. TAG MAKE MODEL static FLA (aMPS) INPUT POWER(w) STANDBY POWER NOTES LOCATION cfm (DBA) SUPPLY (W) (Ø IMPELLER) WEIGHT pressure Cf-1,2 GREEN HECK DS-3-24-70HV CEILING 89400 - 31 460/60/3 500 2.5 128 13 288 213 1 # INTAKE AIR HOOD SCHEDULE REVISIONS1. 2. 3. 4. 5. 6. 7. 8. IDENTIFIER PERFORMANCE DIMENSIONS SPECIFICATIONS INSTALL design static HOOD APPROX. TAG MAKE MODEL THROAT CURB CAP NOTES LOCATION cfm pressure (L X W X H) WEIGHT IAH- 1,2,3,4 GREEN HECK FGI ROOF 15000 .085 60 X 60 108 X 100 X29.5 66 X 66 394 1,2 11/04/202411/26/2024 1. PROVIDE GALVANIZED BIRDSCREEN-0.5 IN MESH TYPE. 2.provide motorized dampers. dampers to be interlocked with individual fans. K.S.B MECHANICAL PLANSSTART DATE:PRINT DATE:DRAWN BY: M0.0 SHEET G A N W EI , # MECHANICAL NOTES = E L O R 1. EXISTING EXHAUST FAN. SET FAN THERMOSTAT TO 90 DEG F. O N 2. CO/NO SENSORS TO BE INTERLOCKED WITH ROOF EXHAUST FANS. ISO O 3. 60" X 60 " INTAKE AIR HOOD ON ROOF. PROVIDE MOTORIZED DAMPER. C M 4. CF-1 AND CF-2 TO BE CONTROLLED BY SINGLE TOUCHSCREEN CONTROL. 5. Final loaction for installation to be verified on site. C& G 5 E 5 EF-2 N 4 (EXISTING) TO ROOF. I 1 AHU-1 (24K) X SERVER T 109 RA OB 1 T TO NEAREST . E CONDENSATE .O DRAIN. PH P NOT IN SCOPE 2 S S 2 MD MD EF-1 EF-4 (ON ROOF) (ON ROOF) 3 3 MD MD IAH-1 IAH-2 (ON ROOF) (ON ROOF) 2 4 S T S 2 5 5 CF-1 CF-2 2 S S 2 3 3 EXISTING. EF EF-2 MD MD ROOF (ON ROOF) TENANT 48 2.017216 51ST AVENUE NE ARLINGTON, WA 98223 MD MD IAH-3 IAH-4 (ON ROOF) (ON ROOF) EF-3 A A 40 X 40 (ON ROOF) M1.0 M1.0 SECURE DUCTWORK 50 X 25 2 TO WALL. S # 40 X 40 SCREENED OPENING. 24" ABOVE FFL. REVISIONS1. 2. 3. 4. 5. 6. 7. 8. DETAIL A (TYP.) 1st FLOOR MECHANICAL PLAN 11/04/202411/26/2024 SCALE:1/8" - 1-0' SCALE: 3/32" = 1-0' K.S.B N MECHANICAL PLANSSTART DATE:PRINT DATE:DRAWN BY: M1.0 SHEET G A N W EI , E # MECHANICAL NOTES = L O R O N 1. EXISTING EXHAUST FAN. SET FAN THERMOSTAT TO 90 DEG F. O O 2. CO/NO SENSORS TO BE INTERLOCKED WITH ROOF EXHAUST FANS. IS M 3. 60" X 60 " INTAKE AIR HOOD ON ROOF. PROVIDE MOTORIZED DAMPER. C 4. CF-1 AND CF-2 TO BE CONTROLLED BY SINGLE TOUCHSCREEN CONTROL. 5. Final loaction for installation to be verified on site. C& G 5 5 HP-1 EN 4 I 1 X 5 RT O A B . E .O PH P 5 5 EF-1 EF-4 IAH-1 IAH-2 5 5 5 5 IAH-3 IAH-4 TENANT 48 2.017216 51ST AVENUE NE ARLINGTON, WA 98223 5 5 EF-2 EF-3 # REVISIONS1. 2. 3. 4. 5. 6. 7. 8. ROOF MECHANICAL PLAN 11/04/202411/26/2024 SCALE: 3/32" = 1-0' K.S.B N MECHANICAL PLANSSTART DATE:PRINT DATE:DRAWN BY: M2.0 SHEET Outdoor Unit Single Zone Heat Pump Ductless System Outdoor Model: 38MARBQ24AA3 Submittal Data Job Data: Location: Buyer: Buyer P.O. #: Carrier #: Unit Number: Model Number: Performance Data Certified By: Date: STANDARD FEATURES • Variable Speed (Inverter) • Factory installed Base Pan Heater • Factory installed Crankcase Heater • Low Voltage Controls • Auto-Restart function • Condenser High Temp Protection • Modes: Cool, Heat, Dry, Fan, Auto • Quiet operation • Anti-corrosive fin coating LIMITED WARRANTY* • 10 year limited to original purchaser on compressor and parts upon timely registration, otherwise 5 years *For residential applications. See warranty for full details. NOTE: Images for illustration purposes only. Actual models may be slightly different. Size 24 Face Area Sq. Ft. 8.2 System Outdoor Model 38MARBQ24AA3 No. Rows 2 Outdoor Coil Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 Fins per inch 20 Electrical MCA A. 25 Circuits 4 MOCP - Fuse Rating A. 35 Type Rotary Inverter Operating Cooling Outdoor DB Min - Max °F(°C) -22~122 (-30~50) Model KTM240D43UKT Range Heating Outdoor DB Min - Max °F(°C) -22~86 (-30~30) Compressor Oil Type VG74 Total Piping Length ft (m) 164 (50) Oil Charge Fl. Oz. 21.0 Piping Piping Lift* ft (m) 82 (25) Rated Current RLA 14.8 Pipe Connection Size - Liquid in (mm) 3/8 (9.52) Unit Width in (mm) 37.24 (946) Pipe Connection Size - Suction in (mm) 5/8 (16) Unit Height in (mm) 31.89 (810) Refrigerant Type R410A Unit Depth in (mm) 16.14 (410) Outdoor Refrigerant Metering Device EEV Net Weight lbs (kg) 134.48 (61) Charge lbs (kg) 5.73 (2.6) Airflow CFM 2,235 * Condensing unit above or below indoor unit Sound Pressure dB(A) 62.0 For Compatibility See Product Data Copyright 2021 CAC/BDP ● Atlanta, GA. 30339 Edition Date: 03/2021 Catalog No: 38MARB-24-3-02SB SUBJECT TO CHANGE WITHOUT NOTICE Page 1 Replaces: 38MARB-24-3-01SB Performance Indoor Model 40MAHBQ24XA3 Energy Star YES Cooling Rated Capacity Btu/h 24,000 Cooling Cap. Range Min - Max Btu/h 6,850~27,000 SEER 21.5 EER 13 Heating Rated Capacity (47°F) Btu/h 29,000 Heating Rated Capacity (17°F) Btu/h 19,800 High WallHeating Maximum Capacity (17°F) Btu/h 24,480 Heating Maximum Capacity (5°F) Btu/h 25,400 Heating Cap. Range Min - Max Btu/h 8,600~31,000 HSPF 12.0 COP (47°F) W/W 3.40 COP (17°F) W/W 3.05 COP (5°F) W/W 1.75 Indoor Model 40MBCQ24---3 Energy Star NO Cooling Rated Capacity Btu/h 24,000 Cooling Cap. Range Min - Max Btu/h 8,000~25,000 SEER 20.0 EER 11 Heating Rated Capacity (47°F) Btu/h 24,000 Heating Rated Capacity (17°F) Btu/h 15,100 CassetteHeating Maximum Capacity (17°F) Btu/h 24,200 Heating Maximum Capacity (5°F) Btu/h 24,100 Heating Cap. Range Min - Max Btu/h 11,840~27,000 HSPF 11.6 COP (47°F) W/W 3.50 COP (17°F) W/W 2.70 COP (5°F) W/W 1.75 Indoor Model 40MBDQ24---3 Energy Star YES Cooling Rated Capacity Btu/h 24,000 Cooling Cap. Range Min - Max Btu/h 6,500~27,800 SEER 20.6 EER 12.5 Heating Rated Capacity (47°F) Btu/h 24,600 Heating Rated Capacity (17°F) Btu/h 16,500 Ducted Heating Maximum Capacity (17°F) Btu/h 26,500 Heating Maximum Capacity (5°F) Btu/h 24,600 Heating Cap. Range Min - Max Btu/h 12,200~32,200 HSPF 12.6 COP (47°F) W/W 3.66 COP (17°F) W/W 2.80 COP (5°F) W/W 2.01 Indoor Model 40MBFQ24---3 Energy Star NO Cooling Rated Capacity Btu/h 24,000 Cooling Cap. Range Min - Max Btu/h 9,000~26,800 SEER 20.2 EER 11.5 Heating Rated Capacity (47°F) Btu/h 24,600 Heating Rated Capacity (17°F) Btu/h 15,240 ConsoleHeating Maximum Capacity (17°F) Btu/h 26,661 Heating Maximum Capacity (5°F) Btu/h 24,100 Heating Cap. Range Min - Max Btu/h 12,500~30,500 HSPF 11.6 COP (47°F) W/W 3.52 COP (17°F) W/W 2.70 COP (5°F) W/W 1.76 Indoor Model 40MBAAQ24XA3 Energy Star YES Cooling Rated Capacity Btu/h 24000 Cooling Cap. Range Min - Max Btu/h 7,500~26,000 SEER 20 EER 13 Heating Rated Capacity (47°F) Btu/h 27000 Heating Rated Capacity (17°F) Btu/h 16500 Heating Maximum Capacity (17°F) Btu/h 25000 Air Handler Heating Maximum Capacity (5°F) Btu/h 22000 Heating Cap. Range Min - Max Btu/h 5,600~31,000 HSPF 12 COP (47°F) W/W 4 COP (17°F) W/W 3 COP (5°F) W/W 2 Copyright 2021 CAC/BDP ● Atlanta, GA. 30339 Edition Date: 03/2021 Catalog No: 38MARB-24-3-02SB SUBJECT TO CHANGE WITHOUT NOTICE Page 2 Replaces: 38MARB-24-3-01SB Construction View Outdoor Model: 38MARBQ24AA3 Copyright 2021 CAC/BDP ● Atlanta, GA. 30339 Edition Date: 03/2021 Catalog No: 38MARB-24-3-02SB SUBJECT TO CHANGE WITHOUT NOTICE Page 3 Replaces: 38MARB-24-3-01SB High Wall Heat Pump Ductless System Indoor Model: 40MAHBQ24XA3 Submittal Data Job Data: Location: Buyer: Buyer P.O. #: Carrier #: Unit Number: Model Number: Performance Data Certified By: Date: STANDARD FEATURES • Modes: Cool, Heat, Dry, Fan, Auto • Turbo Mode • Four fan speeds • Sleep Mode • Relative Humidity Sensor • Intelligent Eye (Occupancy Sensor) • ECO Mode • Up-Down Louver control (fixed or swing) • Follow Me (senses temperature at handheld remote) • Heating Setback (46° F Heating Mode) • Quiet indoor operation • Aluminum Golden Hydrophilic pre-coated fins CONTROLS: • Wireless Remote Controller included with indoor unit LIMITED WARRANTY* • 10 year limited to original purchaser on compressor and parts upon timely registration, otherwise 5 years *For residential applications. See warranty for full details. Size 24 Face Area Sq. Ft. 3.60 System Indoor Model 40MAHBQ24XA3 No. Rows 3 Indoor Coil Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 Fins per inch 20 Electrical Power Supply Indoor unit powered by outdoor unit Circuits 7 MCA A. 0.625 Unit Width in (mm) 44.88 (1140) Wireless Remote Controller (°F/°C Convertible) Standard Unit Height in (mm) 14.57 (370) Controls Wired Remote Controller (°F/°C Convertible) Optional Unit Depth in (mm) 10.83 (275) Operating Cooling Indoor DB Min -Max °F(°C) 63~90 (17~32) Net Weight lbs (kg) 43.65 (19.8) Range Heating Indoor DB Min -Max °F(°C) 32~86 (0~30) Number of Fan Speeds 4 Airflow (lowest to Pipe Connection Size - Liquid in (mm) 3/8 (9.52) CFM 319/414/611/719 highest) Piping Indoor Sound Pressure (lowest Pipe Connection Size - Suction in (mm) 5/8 (16) dB(A) 37/39/44/52 to highest) Air throw Data ft (m) 31.5 (9.6) Pint/h Moisture removal 5.5 (2.6) (L/h) Field Drain Pipe Size in (mm) 0.625 (16) O.D. Performance may vary based on the outdoor unit matched to. See compatible outdoor units pages for Performance Data. For Compatibility See Product Data Copyright 2021 Carrier Corporation ● 7310 W. Morris St. Indianapolis, IN 46231 Edition Date: 02/2021 Catalog No: SUB40MAHB-24-3-02 SUBJECT TO CHANGE WITHOUT NOTICE Page 1 Replaces: SUB40MAHB-24-3-01 Accessories KSACN0801AAA Wired Remote Control 7 Day Programmable KSACN0101AAA Wired Remote Control with Timer Function KSAIF0601AAA Wi-Fi™ Kit High Wall Mid-Tier KSAIC0301230 24V Interface Kit 230V Construction View Indoor Model: 40MAHBQ24XA3 Unit Width in (mm) 44.88 (1140) Unit Height in (mm) 14.57 (370) Unit Depth in (mm) 10.83 (275) Net Weight lbs (kg) 43.65 (19.8) Copyright 2021 Carrier Corporation ● 7310 W. Morris St. Indianapolis, IN 46231 Edition Date: 02/2021 Catalog No: SUB40MAHB-24-3-02 SUBJECT TO CHANGE WITHOUT NOTICE Page 2 Replaces: SUB40MAHB-24-3-01 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: HVLS Model: DS-3-24-70HV Model: DS-3-24-70HV High Volume, Low Speed Ceiling Fan 72.0 3.0 Dimensional Impeller Diameter (ft) 24 Impeller Diameter (in.) 288 Quantity 2 Weight w/o Acc's (lb) 90 Weight w/ Acc's (lb) 213 Installation Clearances Minimum Fan Spacing (ft) 72 Clearance to Wall (ft) 36 Blade Tip Clearance (ft) 3 Vertical Blade Clearance (ft) 3 Standby Blade Deflection (in.) 3.7 Performance Per Fan *Tested Direction of Operation Forward Actual Volume (CFM) 89,400 Coverage Area (ft2) 18,598 Max Coverage Area (ft2) 37,400 Avg. Air Speed (ft/min) 102 Max Avg. Air Speed (ft/min) 186 Fan RPM 30 Max Fan RPM 56 **CFEI at 40% Speed 2.88 **CFEI at 100% Speed 1.27 **Integrated Efficiency - (CFM/W) Total Sound Pressure (dBA) 31 Fan Operation Direction of Operation Forward or Reverse Capability Communication Protocol Modbus RTU Motor Size (W) 500 Notes: Voltage/Cycle/Phase 460/60/3 All dimensions shown are in units of in. (unless specified otherwise) Enclosure IP54 Dimensions shown may vary with fan speed. Consult installation manual for clearance requirements. Max Motor RPM 56 dBA – A weighted sound pressure level measured 5 ft off the ground at 20 ft from the center of the fan – dBA levels ***System FLA (Amps) 2.5 are not licensed by AMCA International **Standby Power (W) 13 *Cataloged performance data tested using forward direction of operation per 10 CFR Part 430. **Input Power (W) 128 **Based on 208/60/3 testing per 10 CFR 430 ***FLA is based on worst case system voltage and phase combination Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 2 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: HVLS Model: DS-3-24-70HV Model: DS-3-24-70HV High Volume, Low Speed Ceiling Fan Standard Construction Features: Heavy duty frame with protective finish - Extruded aluminum airfoils - High efficiency direct drive motor designed for either forward or reverse operation - Factory mounted and wired variable frequency drive - Factory installed plug and play wiring - Universal ceiling mount - Heavy duty safety restraint cable - Airfoil and fan hub retaining systems - AMCA certified for Circulating Fan Performance Selected Options & Accessories: 3 Blade, Extruded Aluminum Airfoil Kit Mill Finish, No Color Aluminum Winglet; Hi-Pro Polyester Finish, Flat Black (044) Color I-Beam Mounting Kit; Hi-Pro Polyester Finish, Flat Black (044) Color 6 ft Drop Length; Hi-Pro Polyester Finish, Flat Black (044) Color Hub Plate and Impeller Hub; Hi-Pro Polyester Finish, Flat Black (044) Color Hub Plate Decal with Greenheck Logo Power Wiring Pigtail, Internal, General, 3 ft of Flexible Power Cord from Unit, Unstripped Wire Plug-and-Play Network Communication Wiring Pigtail, Internal, Terminated with Shielded CAT-5e Splitter (RJ45 Ports) 1,000 ft Bulk Spool of Shielded, Twisted Pair (STP) CAT-5e Control Cable and 20 Shielded RJ45 Connectors Fire Alarm Wiring Pigtail, Internal, 6 ft from Unit, Terminated with Crimp Connector Low-Voltage (24VDC/VAC or 115VAC), Normally Closed Electromechanical Fire Alarm Relay Braided Galvanized Steel Safety Cable, 14 ft from Unit Braided Galvanized Steel Guy Wires, 20 ft from Unit Cable Clamp Hardware for Safety Cable and Guy Wires UL/cUL-507 Listed for Dry Locations Electrical Warranty: 1 Yr (Standard) Mechanical Warranty: 10 Yrs (Standard) Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 3 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: HVLS Model: DS-3-24-70HV Model: DS-3-24-70HV High Volume, Low Speed Ceiling Fan Fan Coverage Data Zone 1 Zone 2 Zone 3 Zone 4 375+ 230+ 105+ <105 Fan Recommended FPM Air FPM Air FPM Air FPM Air Speed Coverage Radius Speed Speed Speed Speed (RPM) Per Fan (ft) Radius Radius Radius Radius (ft) (ft) (ft) (ft) Selected 30 0 19 54 83 77 Maximum 56 22 47 68 87 110 Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 4 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: HVLS Model: DS-3-24-70HV Model: DS-3-24-70HV High Volume, Low Speed Ceiling Fan Fan Spacing & Clearances A - Clearance to Wall (ft) B - Fan Spacing (ft) C - Clearance to Floor (ft) Minimum 36 72 10 Additional Requirements 1. For NFPA 13 compliance in buildings equipped with sprinklers: -Fan must be centered approximately between four adjacent sprinklers -Vertical clearance from fan to sprinkler deflector must be a minimum of 3 ft (36 in.) -Fan must be interlocked to shut down immediately upon a waterflow alarm from the building's fire alarm system -Interlock with building's fire alarm system shall be in accordance with the requirements of NFPA 72 2. Avoid installing fan directly below a light source to prevent a strobing effect that can be caused by fan rotation Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 5 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: HVLS Model: DS-3-24-70HV Model: DS-3-24-70HV High Volume, Low Speed Ceiling Fan Mechanical Installation Requirements Selected Mounting Kit: I-Beam IMPORTANT: HVLS fans must be mounted to building structure as shown in one of the mounting details on this page. Other mounting methods are not acceptable unless approved by Structural Engineer of Record (SEOR). For complete installation instructions, refer to the installation, operation and maintenance manual (IOM). IMPORTANT: Failure to install the fan's safety retention cable and guy wires (if provided) will result in voiding of the fan warranty. Available Mounting Kits (Additional Charges May Apply): Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 6 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: HVLS Model: DS-3-24-70HV Model: DS-3-24-70HV High Volume, Low Speed Ceiling Fan Electrical Installation Requirements IMPORTANT: HVLS fans must be installed with the supplied CAT-5e communication cable or shielded, twisted pair (STP) CAT-5e (by others) that complies with the following specifications. Cable must be twisted pair, shielded 26 ga. CAT-5e cable with a drain wire and must be compliant with ISO 11801. Cable must use shielded RJ45 connectors with a soldered drain and wiring configuration must follow EIA/TIA T568B wiring pinout. Individual CAT-5e cable lengths must not exceed 200 ft. in order to prevent network communication issues. POWER WIRING SHIELDED TWISTED PAIR CAT-5e CONNECTION POWER SOURCE TO NEXT FAN (IF APPLICABLE) RED L3 BLACK L2 TO CONTROL WHITE L1 GREEN GROUND FIRE SYSTEM WIRING (IF APPLICABLE) DIP SWITCH BANK 3 ON SUPPLIED FIRE RELAY FIRE ALARM 1 2 3 4 5 6 7 8 CONTROL PANEL BLACK YELLOW (NC) RED (+) RED RED BLUE (COMMON) WHITE (-) WHITE DIP SWITCH BANK 2 ON 1 2 3 3 HALL CONNECTION NOTE: HALL CABLE PLUG HAS BUILT-IN ALIGNMENT TAB. MOTOR CABLE CONNECTION DO NOT FORCE THIS PLUG POWER 1 GROUND 2 POWER 1 GROUND 2 3 HALL CONNECTION NOTE: If networking multiple HVLS fans to run using a single control source, additional wiring and network modification may be required. Please refer to the fans's installation, operation and maintenance manual (IOM) Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 7 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: HVLS controls Model: HVLS-Controls HVLS Fan Controls Standard Construction Features: HVLS fan controls are designed for use with Greenheck's high volume, low speed (HVLS) ceiling fan products. Each control is configured for communication with one or multiple HVLS fans via the included RJ45 connector. Control Type: Std. Touchscreen Control Quantity: 1 Fans Per Control: 3 Installation Kit: N/A Control Enclosure: Touchscreen interface with IP40 Front enclosure Power Supply: Requires 24V power from fan via shielded, twisted pair (STP) CAT-5e cable Communications: Configured for Modbus RTU Communication with HVLS Fan(s) Included RJ45 Receptacle for Plug-and-Play Communication Wiring to HVLS Fans via Shielded CAT-5e Cable (CAT-5e Cable Provided with HVLS Fans) Fan Operation: Capable of Operating Up to 3 HVLS Fans with Any Combination of Models and Sizes Fans Operate Individually with Unique Speed Settings and Directions of Rotation TOP/BOTTOM 2.75 1.08 FRONT SIDE BACK 2.75 2.75 1.08 4.50 2.21 4.50 4.50 3.29 1.64 NOTE: CONTROL HOLE MOUNTING PATTERN FITS A STANDARD 2X4 JUNCTION BOX Notes: All dimensions shown are in units of in. Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 8 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: EF-1 thru 4 Model: GB-330-VG-50 Ø 58.80 Model: GB-330-VG-50 Belt Drive Centrifugal Roof Exhaust Fan 38.50 Dimensional 50.50 Quantity 4 1.75 Weight w/o Acc's (lb) 230 (12.00) Weight w/ Acc's (lb) 341 Weight w/ Acc's and Curb (lb) 385 Standard Curb Cap Size (in.) 46 x 46 46.00 SQ Optional Damper (in.) 40 x 40 Roof Opening (in.) 42.5 x 42.5 OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR, ADAPTER, AND/OR HINGE BASE. Performance Requested Volume (CFM) 15,000 Actual Volume (CFM) 15,000 Total External SP (in. wg) 0.4 Fan RPM 673 Operating Power (hp) 4.48 Elevation (ft) 433 Airstream Temp.(F) 70 Air Density (lb/ft3) 0.074 Drive Loss (%) 4.0 Tip Speed (ft/min) 6,344 Static Eff. (%) 22 Misc Fan Data Fan Eff. Index (FEI) 0.71 Outlet Velocity (ft/min) 2,389 Motor Motor Included Yes Size (hp) 5 Voltage/Cycle/Phase 460/60/3 Enclosure TEFC Motor RPM 1725 Efficiency Rating High Windings 1 NEC FLA* (Amps) 7.6 Min. Circuit Ampacity (MCA) 9 Notes: Max. Overcurrent Protection (MOP) 20 All dimensions shown are in units of in. *NEC FLA, MCA and MOP are for reference only – based on Short Circuit Current Rtg (SCCR) 5 kA tables 430.248 or 430.25 of National Electric Code 2020. Actual motor FLA may vary, for sizing thermal overload, consult factory. MCA and MOP values shown only account for the motor, not accessories (damper actuator, field supplied VFD, etc). Sound Power by Octave Band LwA - A weighted sound power level, based on ANSI S1.4 dBA - A weighted sound pressure level, based on 11.5 dB Sound attenuation per Octave band at 5 ft - dBA levels are not licensed Data 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones by AMCA International Sones - calculated using ANSI/AMCA 301 at 5 ft Inlet 89 94 86 83 79 76 69 64 86 74 25 Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 9 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: EF-1 thru 4 Model: GB-330-VG-50 Model: GB-330-VG-50 Belt Drive Centrifugal Roof Exhaust Fan Tags: EF-1 EF-2 EF-3 EF-4 Standard Construction Features: - Aluminum housing - Backward inclined aluminum wheel - Curb cap with prepunched mounting holes - Motor and drives isolated on shock mounts - Birdscreen - Ball bearing motors - Adjustable motor pulley - Adjustable motor plate - Fan shaft mounted in ball bearing pillow blocks - Bearings meet or exceed temperature rating of fan - Static resistant belts - Corrosion resistant fasteners - Sizes 141 and larger have internal Lifting lugs Selected Options & Accessories: High Efficient Motor - meets Greenheck High Efficiency Table Motor - Vari-Green EC motor Control - Dial for balancing Provided motor meets the motor efficiency requirements set forth in 2015 Washington St Energy Code Standard Curb Cap Size - 46 Square UL/cUL 705 Listed - "Power Ventilators" Switch, NEMA-1, Toggle, Junction Box Mounted & Wired in weather-protected motor compartment Birdscreen: Galvanized, nom. 84% Free Area Bearings with Grease Fittings, L10 life of 100,000 hrs (L50 avg. life 500,000 hrs) Conduit Chase Qty 1 Unit Warranty: 1 Yr (Standard) Not available to ship to California Damper Shipped Loose, VCD-23-PB-40X40, Not Coated, Nominal Size Damper Actuator (FSNF24), 24 VDC Actuated Selected Sub Marks See individual submittals for full details GPI-46-G12 The Vari-Green Motor included in this order can operate on any three phase voltage between 380V and 480V. Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 10 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: EF-1 thru 4 Model: GB-330-VG-50 Vari-Green Motor & Control Options An EC motor that uses AC input power and internally converts it to DC power. Potentiometer (dial) mounted on the motor enclosure adjusts the speed (RPM) down 80%. Vari-Green motors feature a soft-start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. Motor Configuration Input Voltage: 460 Speed Reference: Dial on Motor Permanent Dial: Yes Control Configuration Control Type: Dial on Motor Transformer: None Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 11 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: EF-1 thru 4 Model: GPI-46-G12 44.50 44.50 Model: GPI Roof Curb 12.00 Tags: EF-1 EF-2 EF-3 EF-4 48.50 48.50 Standard Construction Features: - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure - Constructed of either 18 ga galvanized steel or 0.064 in. aluminum - Straight Sided without a cant - 2 in. mounting flange - 3 lb density insulation - Height - Available from 12 in. to 42 in. as specified in 0.5 in. increments. Notes: - The maximum roof opening dimension should not be greater than the "Actual" top outside dimension minus 2 in.. - The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. - The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. - Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. General Sizing Undersizing Weight Shipped Tag Qty Model Method (in.) (lb) Assembled Union Label No 4 GPI-46 Nominal 1.5 44 Yes Preference Dimensions Nominal Nominal Actual Actual Actual Actual Hinge Hinge Curb Outside Outside Outside Outside Inside Inside Base Base Height Width Length Width Length Width Length Width* Length* (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) 12 46 46 44.5 44.5 41 41 45 45 *May not be applicable Accessories Security Insulation Insulation Material Bars Liner (in.) R Value Galvanized No No 1 R4.3 Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 12 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: Intake Hood Model: FGI Model: FGI Standard Construction Features: -Precision formed locked rib construction. -Available in aluminum or galvanized steel construction. -0.5 in. galvanized steel mesh birdscreens. -Heavy gauge galvanized steel support members. -Hood can be removed completely from the base or hinged open. -Units with a throat size exceeding 60 in. x 120 in. will have 12 in. galvanized bases as standard. -Recommended roof opening dimension is at least 2.5 in. larger than the damper size. Dimensions Throat Throat Hood Hood Hood Curb Cap Curb Cap Width Length Width Length Height Width Length Weight Ship ID# Tag Qty Model TW (in.) TL (in.) A (in.) B (in.) C (in.) (in.) (in.) (lb) Assembled 6-1 4 FGI-60x60 60 60 100 108 29.5 66 66 394 No Performance Throat Volume Throat AreaVelocity (ft/ ID# Tag Qty (CFM) SP (in. wg) (ft2) min) 6-1 4 15,000 0.085 25 600 Construction Installation Insect Base Birdscreen Unit ID# Type Screen Height (in.) Material Material 6-1 Non-Ducted No 5 Galvanized Galvanized Accessories Texas Department of Florida Insurance Hood Supply High Wind Product Miami-Dade Product Insulation Tie Down ID# Filters Rated Approval # NOA# Evaluation Curb Seal (in.) Points 6-1 No No N/A N/A N/A No None No Roof Curbs Height Width Length ID# Model (in.) (in.) (in.) 6-1 GPI 12 66 66 Dampers Width Length Blade Frame Actuator Actuator End Damper ID# Model (in.) (in.) Action Type Actuator Type Quantity Mounting Switch Mounting 6-1 VCD-23 60 60 Parallel Channel 24 VAC 1 Internal No Ship Separate Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 13 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: Intake Hood Model: FGI Standard Construction Features: Control Damper Model: VCD-23 - Model VCD-23 is a well built low leakage control damper for automatic control or manual balancing applications - Galvanized 16 ga channel frame - Galvanized blades with reinforcements - Side mounted steel linkage is concealed in the frame to prevent additional pressure drop - Axles are steel and 0.5 in. dia.- Synthetic axle bearings - Width and height furnished approximately 0.25 in. undersized - Field wiring is required to individual components Damper Configuration: ID #: Tag: Quantity: W (in.): H (in.): Act Qty: 6-1 4 60 60 1 Notes: All dimensions shown are in units of in. Width And height furnished approximately 0.25 in. undersize Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 14 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: Intake Hood Model: GPI Model: GPI Roof Curb Standard Construction Features: - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure - Constructed of either 18 ga galvanized steel or 0.064 in. aluminum - Straight Sided without a cant - 2 in. mounting flange - 3 lb density insulation - Height - Available from 12 in. to 42 in. as specified in 0.5 in. increments. Notes: - The maximum roof opening dimension should not be greater than the "Actual" top outside dimension minus 2 in.. - The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. - The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. - Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. General Sizing Undersizing Weight Shipped ID# Tag Qty Model Method (in.) (lb) Assembled Union Made 6-1 No 4 GPI-66-G12 Nominal 1.5 77 Yes Preference Dimensions Nominal Nominal Actual Actual Curb Outside Outside Outside Outside Height Width Length Width Length ID# (in.) (in.) (in.) (in.) (in.) 6-1 12 66 66 64.5 64.5 *May not be applicable Accessories Security Insulation Insulation ID# Material Bars Liner (in.) R Value 6-1 Galvanized No No 1 R4.3 Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 15 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Roof Curb Standard Construction Features: Model: GPI - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure - Constructed of either 18 ga galvanized steel or 0.064 in. aluminum - Straight Sided without a cant - 2 in. mounting flange - 3 lb density insulation - Height - Available from 12 in. to 42 in. as specified in 0.5 in. increments. Notes: - The maximum roof opening dimension should not be greater than the "Actual" top outside dimension minus 2 in.. - The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. - The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. - Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. Roof Curb Configuration: ID #: Tag: Qty: Curb Cap W x L: Actual W x L: Flange W: Flange L: Height: Step Hgt: Damper Tray W x L: 9 (Multiple) 4 46 x 46 44.5 x 44.5 48.5 48.5 12 N/A x 15 Intake Hood 1 66 x 66 64.5 x 64.5 68.5 68.5 12 N/A x Notes: All dimensions shown are in units of in. Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 16 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Control Damper Standard Construction Features: Model: VCD-23 - Model VCD-23 is a well built low leakage control damper for automatic control or manual balancing applications - Galvanized 16 ga channel frame - Galvanized blades with reinforcements - Side mounted steel linkage is concealed in the frame to prevent additional pressure drop - Axles are steel and 0.5 in. dia.- Synthetic axle bearings - Width and height furnished approximately 0.25 in. undersized - Field wiring is required to individual components Damper Configuration: ID #: Tag: Quantity: W (in.): H (in.): Act Qty: Actuator Model: 9 (Multiple) 4 40 40 1 FSNF24 15 Intake Hood 1 60 60 Notes: All dimensions shown are in units of in. Width And height furnished approximately 0.25 in. undersize Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 17 of 17 PRECISE HEATING AND COOLING, LLC SUBMITTAL DOCUMENTS Project: TENANT 48 2.0 @ ARLINGTON 11-26-2024 HVAC UNITS Outdoor Unit – 38MARBQ24AA3 Indoor Unit – 40MAHBQ24XA3 CEILING FANS DS-3-24-70HV EXHAUST FANS GB-330-VG-50 OUTDOOR AIR INTAKE HOODS FGI 60 X 60 CO/NO SENSOR BELIMO Outdoor Unit Single Zone Heat Pump Ductless System Outdoor Model: 38MARBQ24AA3 Submittal Data Job Data: Location: Buyer: Buyer P.O. #: Carrier #: Unit Number: Model Number: Performance Data Certified By: Date: STANDARD FEATURES • Variable Speed (Inverter) • Factory installed Base Pan Heater • Factory installed Crankcase Heater • Low Voltage Controls • Auto-Restart function • Condenser High Temp Protection • Modes: Cool, Heat, Dry, Fan, Auto • Quiet operation • Anti-corrosive fin coating LIMITED WARRANTY* • 10 year limited to original purchaser on compressor and parts upon timely registration, otherwise 5 years *For residential applications. See warranty for full details. NOTE: Images for illustration purposes only. Actual models may be slightly different. Size 24 Face Area Sq. Ft. 8.2 System Outdoor Model 38MARBQ24AA3 No. Rows 2 Outdoor Coil Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 Fins per inch 20 Electrical MCA A. 25 Circuits 4 MOCP - Fuse Rating A. 35 Type Rotary Inverter Operating Cooling Outdoor DB Min - Max °F(°C) -22~122 (-30~50) Model KTM240D43UKT Range Heating Outdoor DB Min - Max °F(°C) -22~86 (-30~30) Compressor Oil Type VG74 Total Piping Length ft (m) 164 (50) Oil Charge Fl. Oz. 21.0 Piping Piping Lift* ft (m) 82 (25) Rated Current RLA 14.8 Pipe Connection Size - Liquid in (mm) 3/8 (9.52) Unit Width in (mm) 37.24 (946) Pipe Connection Size - Suction in (mm) 5/8 (16) Unit Height in (mm) 31.89 (810) Refrigerant Type R410A Unit Depth in (mm) 16.14 (410) Outdoor Refrigerant Metering Device EEV Net Weight lbs (kg) 134.48 (61) Charge lbs (kg) 5.73 (2.6) Airflow CFM 2,235 * Condensing unit above or below indoor unit Sound Pressure dB(A) 62.0 For Compatibility See Product Data Copyright 2021 CAC/BDP ● Atlanta, GA. 30339 Edition Date: 03/2021 Catalog No: 38MARB-24-3-02SB SUBJECT TO CHANGE WITHOUT NOTICE Page 1 Replaces: 38MARB-24-3-01SB Performance Indoor Model 40MAHBQ24XA3 Energy Star YES Cooling Rated Capacity Btu/h 24,000 Cooling Cap. Range Min - Max Btu/h 6,850~27,000 SEER 21.5 EER 13 Heating Rated Capacity (47°F) Btu/h 29,000 Heating Rated Capacity (17°F) Btu/h 19,800 High WallHeating Maximum Capacity (17°F) Btu/h 24,480 Heating Maximum Capacity (5°F) Btu/h 25,400 Heating Cap. Range Min - Max Btu/h 8,600~31,000 HSPF 12.0 COP (47°F) W/W 3.40 COP (17°F) W/W 3.05 COP (5°F) W/W 1.75 Indoor Model 40MBCQ24---3 Energy Star NO Cooling Rated Capacity Btu/h 24,000 Cooling Cap. Range Min - Max Btu/h 8,000~25,000 SEER 20.0 EER 11 Heating Rated Capacity (47°F) Btu/h 24,000 Heating Rated Capacity (17°F) Btu/h 15,100 CassetteHeating Maximum Capacity (17°F) Btu/h 24,200 Heating Maximum Capacity (5°F) Btu/h 24,100 Heating Cap. Range Min - Max Btu/h 11,840~27,000 HSPF 11.6 COP (47°F) W/W 3.50 COP (17°F) W/W 2.70 COP (5°F) W/W 1.75 Indoor Model 40MBDQ24---3 Energy Star YES Cooling Rated Capacity Btu/h 24,000 Cooling Cap. Range Min - Max Btu/h 6,500~27,800 SEER 20.6 EER 12.5 Heating Rated Capacity (47°F) Btu/h 24,600 Heating Rated Capacity (17°F) Btu/h 16,500 Ducted Heating Maximum Capacity (17°F) Btu/h 26,500 Heating Maximum Capacity (5°F) Btu/h 24,600 Heating Cap. Range Min - Max Btu/h 12,200~32,200 HSPF 12.6 COP (47°F) W/W 3.66 COP (17°F) W/W 2.80 COP (5°F) W/W 2.01 Indoor Model 40MBFQ24---3 Energy Star NO Cooling Rated Capacity Btu/h 24,000 Cooling Cap. Range Min - Max Btu/h 9,000~26,800 SEER 20.2 EER 11.5 Heating Rated Capacity (47°F) Btu/h 24,600 Heating Rated Capacity (17°F) Btu/h 15,240 ConsoleHeating Maximum Capacity (17°F) Btu/h 26,661 Heating Maximum Capacity (5°F) Btu/h 24,100 Heating Cap. Range Min - Max Btu/h 12,500~30,500 HSPF 11.6 COP (47°F) W/W 3.52 COP (17°F) W/W 2.70 COP (5°F) W/W 1.76 Indoor Model 40MBAAQ24XA3 Energy Star YES Cooling Rated Capacity Btu/h 24000 Cooling Cap. Range Min - Max Btu/h 7,500~26,000 SEER 20 EER 13 Heating Rated Capacity (47°F) Btu/h 27000 Heating Rated Capacity (17°F) Btu/h 16500 Heating Maximum Capacity (17°F) Btu/h 25000 Air Handler Heating Maximum Capacity (5°F) Btu/h 22000 Heating Cap. Range Min - Max Btu/h 5,600~31,000 HSPF 12 COP (47°F) W/W 4 COP (17°F) W/W 3 COP (5°F) W/W 2 Copyright 2021 CAC/BDP ● Atlanta, GA. 30339 Edition Date: 03/2021 Catalog No: 38MARB-24-3-02SB SUBJECT TO CHANGE WITHOUT NOTICE Page 2 Replaces: 38MARB-24-3-01SB Construction View Outdoor Model: 38MARBQ24AA3 Copyright 2021 CAC/BDP ● Atlanta, GA. 30339 Edition Date: 03/2021 Catalog No: 38MARB-24-3-02SB SUBJECT TO CHANGE WITHOUT NOTICE Page 3 Replaces: 38MARB-24-3-01SB High Wall Heat Pump Ductless System Indoor Model: 40MAHBQ24XA3 Submittal Data Job Data: Location: Buyer: Buyer P.O. #: Carrier #: Unit Number: Model Number: Performance Data Certified By: Date: STANDARD FEATURES • Modes: Cool, Heat, Dry, Fan, Auto • Turbo Mode • Four fan speeds • Sleep Mode • Relative Humidity Sensor • Intelligent Eye (Occupancy Sensor) • ECO Mode • Up-Down Louver control (fixed or swing) • Follow Me (senses temperature at handheld remote) • Heating Setback (46° F Heating Mode) • Quiet indoor operation • Aluminum Golden Hydrophilic pre-coated fins CONTROLS: • Wireless Remote Controller included with indoor unit LIMITED WARRANTY* • 10 year limited to original purchaser on compressor and parts upon timely registration, otherwise 5 years *For residential applications. See warranty for full details. Size 24 Face Area Sq. Ft. 3.60 System Indoor Model 40MAHBQ24XA3 No. Rows 3 Indoor Coil Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 Fins per inch 20 Electrical Power Supply Indoor unit powered by outdoor unit Circuits 7 MCA A. 0.625 Unit Width in (mm) 44.88 (1140) Wireless Remote Controller (°F/°C Convertible) Standard Unit Height in (mm) 14.57 (370) Controls Wired Remote Controller (°F/°C Convertible) Optional Unit Depth in (mm) 10.83 (275) Operating Cooling Indoor DB Min -Max °F(°C) 63~90 (17~32) Net Weight lbs (kg) 43.65 (19.8) Range Heating Indoor DB Min -Max °F(°C) 32~86 (0~30) Number of Fan Speeds 4 Airflow (lowest to Pipe Connection Size - Liquid in (mm) 3/8 (9.52) CFM 319/414/611/719 highest) Piping Indoor Sound Pressure (lowest Pipe Connection Size - Suction in (mm) 5/8 (16) dB(A) 37/39/44/52 to highest) Air throw Data ft (m) 31.5 (9.6) Pint/h Moisture removal 5.5 (2.6) (L/h) Field Drain Pipe Size in (mm) 0.625 (16) O.D. Performance may vary based on the outdoor unit matched to. See compatible outdoor units pages for Performance Data. For Compatibility See Product Data Copyright 2021 Carrier Corporation ● 7310 W. Morris St. Indianapolis, IN 46231 Edition Date: 02/2021 Catalog No: SUB40MAHB-24-3-02 SUBJECT TO CHANGE WITHOUT NOTICE Page 1 Replaces: SUB40MAHB-24-3-01 Accessories KSACN0801AAA Wired Remote Control 7 Day Programmable KSACN0101AAA Wired Remote Control with Timer Function KSAIF0601AAA Wi-Fi™ Kit High Wall Mid-Tier KSAIC0301230 24V Interface Kit 230V Construction View Indoor Model: 40MAHBQ24XA3 Unit Width in (mm) 44.88 (1140) Unit Height in (mm) 14.57 (370) Unit Depth in (mm) 10.83 (275) Net Weight lbs (kg) 43.65 (19.8) Copyright 2021 Carrier Corporation ● 7310 W. Morris St. Indianapolis, IN 46231 Edition Date: 02/2021 Catalog No: SUB40MAHB-24-3-02 SUBJECT TO CHANGE WITHOUT NOTICE Page 2 Replaces: SUB40MAHB-24-3-01 Printed Date: 01/16/2025 Job: Tenant 48 Warehouse Mark: HVLS (1) Model: DS-3-24-70HV Model: DS-3-24-70HV 42.0 High Volume, Low Speed Ceiling Fan 3.0 Dimensional Impeller Diameter (ft) 24 Impeller Diameter (in.) 288 Quantity 2 Weight w/o Acc's (lb) 90 Weight w/ Acc's (lb) 206 Installation Clearances Minimum Fan Spacing (ft) 72 Clearance to Wall (ft) 36 Blade Tip Clearance (ft) 3 Vertical Blade Clearance (ft) 3 Standby Blade Deflection (in.) 3.7 Performance Per Fan *Tested Direction of Operation Forward Actual Volume (CFM) 89,400 Coverage Area (ft2) 18,598 Max Coverage Area (ft2) 37,400 Avg. Air Speed (ft/min) 102 Max Avg. Air Speed (ft/min) 186 Fan RPM 30 Max Fan RPM 56 **CFEI at 40% Speed 2.88 **CFEI at 100% Speed 1.27 **Integrated Efficiency - (CFM/W) Total Sound Pressure (dBA) 31 Fan Operation Direction of Operation Forward or Reverse Capability Communication Protocol Modbus RTU Motor Size (W) 500 Notes: Voltage/Cycle/Phase 460/60/3 All dimensions shown are in units of in. (unless specified otherwise) Enclosure IP54 Dimensions shown may vary with fan speed. Consult installation manual for clearance requirements. Max Motor RPM 56 dBA – A weighted sound pressure level measured 5 ft off the ground at 20 ft from the center of the fan – dBA levels ***System FLA (Amps) 2.5 are not licensed by AMCA International **Standby Power (W) 13 *Cataloged performance data tested using forward direction of operation per 10 CFR Part 430. **Input Power (W) 128 **Based on 208/60/3 testing per 10 CFR 430 ***FLA is based on worst case system voltage and phase combination Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.46.1024 Generated by: matt@dorse.com Page 1 of 11 Printed Date: 01/16/2025 Job: Tenant 48 Warehouse Mark: HVLS (1) Model: DS-3-24-70HV Model: DS-3-24-70HV High Volume, Low Speed Ceiling Fan Standard Construction Features: Heavy duty frame with protective finish - Extruded aluminum airfoils - High efficiency direct drive motor designed for either forward or reverse operation - Factory mounted and wired variable frequency drive - Factory installed plug and play wiring - Universal ceiling mount - Heavy duty safety restraint cable - Airfoil and fan hub retaining systems - AMCA certified for Circulating Fan Performance Selected Options & Accessories: 3 Blade, Extruded Aluminum Airfoil Kit Mill Finish, No Color Aluminum Winglet; Hi-Pro Polyester Finish, Flat Black (044) Color I-Beam Mounting Kit; Hi-Pro Polyester Finish, Flat Black (044) Color 3.5 ft Drop Length; Hi-Pro Polyester Finish, Flat Black (044) Color Hub Plate and Impeller Hub; Hi-Pro Polyester Finish, Flat Black (044) Color Hub Plate Decal with Greenheck Logo Power Wiring Pigtail, Internal, General, 3 ft of Flexible Power Cord from Unit, Unstripped Wire Plug-and-Play Network Communication Wiring Pigtail, Internal, Terminated with Shielded CAT-5e Splitter (RJ45 Ports) 1,000 ft Bulk Spool of Shielded, Twisted Pair (STP) CAT-5e Control Cable and 20 Shielded RJ45 Connectors Fire Alarm Wiring Pigtail, Internal, 2.5 ft from Unit, Terminated with Crimp Connector Low-Voltage (24VDC/VAC or 115VAC), Normally Closed Electromechanical Fire Alarm Relay Braided Galvanized Steel Safety Cable, 16 ft from Unit Braided Galvanized Steel Guy Wires, 20 ft from Unit Cable Clamp Hardware for Safety Cable and Guy Wires UL/cUL-507 Listed for Dry Locations Electrical Warranty: 1 Yr (Standard) Mechanical Warranty: 10 Yrs (Standard) Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.46.1024 Generated by: matt@dorse.com Page 2 of 11 Printed Date: 01/16/2025 Job: Tenant 48 Warehouse Mark: HVLS (1) Model: DS-3-24-70HV Model: DS-3-24-70HV High Volume, Low Speed Ceiling Fan Fan Coverage Data Zone 1 Zone 2 Zone 3 Zone 4 375+ 230+ 105+ <105 Fan Recommended FPM Air FPM Air FPM Air FPM Air Speed Coverage Radius Speed Speed Speed Speed (RPM) Per Fan (ft) Radius Radius Radius Radius (ft) (ft) (ft) (ft) Selected 30 0 19 54 83 77 Maximum 56 22 47 68 87 110 Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.46.1024 Generated by: matt@dorse.com Page 3 of 11 Printed Date: 01/16/2025 Job: Tenant 48 Warehouse Mark: HVLS (1) Model: DS-3-24-70HV Model: DS-3-24-70HV High Volume, Low Speed Ceiling Fan Recommended Layout Space Length (ft) 0 100 200 Air Speed (ft/min) 50 500 375 Row ID 230 # 1 105 100 0 Space Width (ft) 150 Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.46.1024 Generated by: matt@dorse.com Page 4 of 11 X-Y Horizontal Total # of Fans Coordinates of Spacing Row ID in Row First Fan in Between Fans Row (ft, ft) (ft) 1 2 (54, 86) 107 Printed Date: 01/16/2025 Job: Tenant 48 Warehouse Mark: HVLS (1) Model: DS-3-24-70HV Model: DS-3-24-70HV High Volume, Low Speed Ceiling Fan Fan Spacing & Clearances A - Clearance to Wall (ft) B - Fan Spacing (ft) C - Clearance to Floor (ft) Minimum 36 72 10 Additional Requirements 1. For NFPA 13 compliance in buildings equipped with sprinklers: -Fan must be centered approximately between four adjacent sprinklers -Vertical clearance from fan to sprinkler deflector must be a minimum of 3 ft (36 in.) -Fan must be interlocked to shut down immediately upon a waterflow alarm from the building's fire alarm system -Interlock with building's fire alarm system shall be in accordance with the requirements of NFPA 72 2. Avoid installing fan directly below a light source to prevent a strobing effect that can be caused by fan rotation Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.46.1024 Generated by: matt@dorse.com Page 5 of 11 Printed Date: 01/16/2025 Job: Tenant 48 Warehouse Mark: HVLS (1) Model: DS-3-24-70HV Perceived Cooling Effect Feels 6°F Cooler Perceived Cooling Effect Based on ASHRAE 55-2017 Perceived Coverage Area Operative Relative Metabolic Avg. Air Speed Clothing Level Cooling Per Fan (ft2) Temp. (F) Humidity (%) Rate (ft/min) Effect (F) 0.57 Pants, Short 18,598 77 60 1.7 Walking 102 6 Sleeves Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.46.1024 Generated by: matt@dorse.com Page 6 of 11 Printed Date: 01/16/2025 Job: Tenant 48 Warehouse Mark: HVLS (1) Model: DS-3-24-70HV Payback Analysis Payback Inputs Electric Cost (USD/ Heating Cost (USD/ Operating Time Heat Source KwH) therm) 24 hours/day, 7 0.08 Gas 0.80 days/week Winter Destratification Energy Savings Estimated Heating Load Annual Energy Cost HVLS Energy Cost Net Energy Cost Without HVLS With HVLS Savings (USD) (USD) Savings (USD) 284,728.0 191,126.0 5,785 79 5,706 Summer Cooling Energy Savings Estimated Cooling Load Annual Energy Cost HVLS Energy Cost Net Energy Cost Without HVLS With HVLS Savings (USD) (USD) Savings (USD) 0.0 0.0 0 0 0 Equipment Cost Estimated HVLS Avoided A/C Equipment First Cost Equipment Cost Net First Cost (USD) (USD) (USD) 14,490 0 14,490 Payback Net Operating Payback Period Savings Per Year (Years) (USD) 5,706 2.5 Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.46.1024 Generated by: matt@dorse.com Page 7 of 11 Printed Date: 01/16/2025 Job: Tenant 48 Warehouse Mark: HVLS (1) Model: DS-3-24-70HV Model: DS-3-24-70HV Finish Selection Selected Frame Finish Finish Type Hi-Pro Polyester Mount Finish Color Flat Black (044) Downtube Finish Color Flat Black (044) Hub/Hub Plate Finish Color Flat Black (044) Winglet Finish Color Flat Black (044) Selected Airfoil Finish Finish Type Mill Finish Color None Available Finish Options (Additional Charges May Apply): Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.46.1024 Generated by: matt@dorse.com Page 8 of 11 Printed Date: 01/16/2025 Job: Tenant 48 Warehouse Mark: HVLS (1) Model: DS-3-24-70HV Model: DS-3-24-70HV High Volume, Low Speed Ceiling Fan Mechanical Installation Requirements Selected Mounting Kit: I-Beam IMPORTANT: HVLS fans must be mounted to building structure as shown in one of the mounting details on this page. Other mounting methods are not acceptable unless approved by Structural Engineer of Record (SEOR). For complete installation instructions, refer to the installation, operation and maintenance manual (IOM). IMPORTANT: Failure to install the fan's safety retention cable and guy wires (if provided) will result in voiding of the fan warranty. Available Mounting Kits (Additional Charges May Apply): Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.46.1024 Generated by: matt@dorse.com Page 9 of 11 Printed Date: 01/16/2025 Job: Tenant 48 Warehouse Mark: HVLS (1) Model: DS-3-24-70HV Model: DS-3-24-70HV High Volume, Low Speed Ceiling Fan Electrical Installation Requirements IMPORTANT: HVLS fans must be installed with the supplied CAT-5e communication cable or shielded, twisted pair (STP) CAT-5e (by others) that complies with the following specifications. Cable must be twisted pair, shielded 26 ga. CAT-5e cable with a drain wire and must be compliant with ISO 11801. Cable must use shielded RJ45 connectors with a soldered drain and wiring configuration must follow EIA/TIA T568B wiring pinout. Individual CAT-5e cable lengths must not exceed 200 ft. in order to prevent network communication issues. POWER WIRING SHIELDED TWISTED PAIR CAT-5e CONNECTION POWER SOURCE TO NEXT FAN (IF APPLICABLE) RED L3 BLACK L2 TO CONTROL WHITE L1 GREEN GROUND FIRE SYSTEM WIRING (IF APPLICABLE) DIP SWITCH BANK 3 ON SUPPLIED FIRE RELAY FIRE ALARM 1 2 3 4 5 6 7 8 CONTROL PANEL BLACK YELLOW (NC) RED (+) RED RED BLUE (COMMON) WHITE (-) WHITE DIP SWITCH BANK 2 ON 1 2 3 3 HALL CONNECTION NOTE: HALL CABLE PLUG HAS BUILT-IN ALIGNMENT TAB. MOTOR CABLE CONNECTION DO NOT FORCE THIS PLUG POWER 1 GROUND 2 POWER 1 GROUND 2 3 HALL CONNECTION NOTE: If networking multiple HVLS fans to run using a single control source, additional wiring and network modification may be required. Please refer to the fans's installation, operation and maintenance manual (IOM) Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.46.1024 Generated by: matt@dorse.com Page 10 of 11 Printed Date: 01/16/2025 Job: Tenant 48 Warehouse Mark: HVLS (1) Model: DS-3-24-70HV Model: DS-3-24-70HV High Volume, Low Speed Ceiling Fan HVLS Fan Compliance Department of Energy (DOE) 10 CFR Part 430 Compliance DOE Min. CFEI at Calculated CFEI at DOE Min. CFEI at Calculated CFEI at DOE Min. Efficiency Calculated Efficiency Compliance 40% Speed 40% Speed 100% Speed 100% Speed (CFM/W) (CFM/W) 1.31 2.88 1.00 1.27 - - Yes ASHRAE 55-2017 Compliance Perceived Acceptable Calculated Operative Relative Metabolic Avg. Air Speed Thermal Clothing Level Cooling Effect Predicted Mean Predicted Mean Compliance Temp. (F) Humidity (%) Rate (ft/min) Sensation (F) Vote (PMV) Vote (PMV) 0.57 Pants, -0.5 ≤ PMV ≤ 77 60 1.7 Walking 102 6 0.2 Neutral Yes Short Sleeves 0.5 Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.46.1024 Generated by: matt@dorse.com Page 11 of 11 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: EF-1 thru 4 Model: GB-330-VG-50 Ø 58.80 Model: GB-330-VG-50 Belt Drive Centrifugal Roof Exhaust Fan 38.50 Dimensional 50.50 Quantity 4 1.75 Weight w/o Acc's (lb) 230 (12.00) Weight w/ Acc's (lb) 341 Weight w/ Acc's and Curb (lb) 385 Standard Curb Cap Size (in.) 46 x 46 46.00 SQ Optional Damper (in.) 40 x 40 Roof Opening (in.) 42.5 x 42.5 OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR, ADAPTER, AND/OR HINGE BASE. Performance Requested Volume (CFM) 15,000 Actual Volume (CFM) 15,000 Total External SP (in. wg) 0.4 Fan RPM 673 Operating Power (hp) 4.48 Elevation (ft) 433 Airstream Temp.(F) 70 Air Density (lb/ft3) 0.074 Drive Loss (%) 4.0 Tip Speed (ft/min) 6,344 Static Eff. (%) 22 Misc Fan Data Fan Eff. Index (FEI) 0.71 Outlet Velocity (ft/min) 2,389 Motor Motor Included Yes Size (hp) 5 Voltage/Cycle/Phase 460/60/3 Enclosure TEFC Motor RPM 1725 Efficiency Rating High Windings 1 NEC FLA* (Amps) 7.6 Min. Circuit Ampacity (MCA) 9 Notes: Max. Overcurrent Protection (MOP) 20 All dimensions shown are in units of in. *NEC FLA, MCA and MOP are for reference only – based on Short Circuit Current Rtg (SCCR) 5 kA tables 430.248 or 430.25 of National Electric Code 2020. Actual motor FLA may vary, for sizing thermal overload, consult factory. MCA and MOP values shown only account for the motor, not accessories (damper actuator, field supplied VFD, etc). Sound Power by Octave Band LwA - A weighted sound power level, based on ANSI S1.4 dBA - A weighted sound pressure level, based on 11.5 dB Sound attenuation per Octave band at 5 ft - dBA levels are not licensed Data 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones by AMCA International Sones - calculated using ANSI/AMCA 301 at 5 ft Inlet 89 94 86 83 79 76 69 64 86 74 25 Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 9 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: EF-1 thru 4 Model: GB-330-VG-50 Model: GB-330-VG-50 Belt Drive Centrifugal Roof Exhaust Fan Tags: EF-1 EF-2 EF-3 EF-4 Standard Construction Features: - Aluminum housing - Backward inclined aluminum wheel - Curb cap with prepunched mounting holes - Motor and drives isolated on shock mounts - Birdscreen - Ball bearing motors - Adjustable motor pulley - Adjustable motor plate - Fan shaft mounted in ball bearing pillow blocks - Bearings meet or exceed temperature rating of fan - Static resistant belts - Corrosion resistant fasteners - Sizes 141 and larger have internal Lifting lugs Selected Options & Accessories: High Efficient Motor - meets Greenheck High Efficiency Table Motor - Vari-Green EC motor Control - Dial for balancing Provided motor meets the motor efficiency requirements set forth in 2015 Washington St Energy Code Standard Curb Cap Size - 46 Square UL/cUL 705 Listed - "Power Ventilators" Switch, NEMA-1, Toggle, Junction Box Mounted & Wired in weather-protected motor compartment Birdscreen: Galvanized, nom. 84% Free Area Bearings with Grease Fittings, L10 life of 100,000 hrs (L50 avg. life 500,000 hrs) Conduit Chase Qty 1 Unit Warranty: 1 Yr (Standard) Not available to ship to California Damper Shipped Loose, VCD-23-PB-40X40, Not Coated, Nominal Size Damper Actuator (FSNF24), 24 VDC Actuated Selected Sub Marks See individual submittals for full details GPI-46-G12 The Vari-Green Motor included in this order can operate on any three phase voltage between 380V and 480V. Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 10 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: EF-1 thru 4 Model: GB-330-VG-50 Vari-Green Motor & Control Options An EC motor that uses AC input power and internally converts it to DC power. Potentiometer (dial) mounted on the motor enclosure adjusts the speed (RPM) down 80%. Vari-Green motors feature a soft-start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. Motor Configuration Input Voltage: 460 Speed Reference: Dial on Motor Permanent Dial: Yes Control Configuration Control Type: Dial on Motor Transformer: None Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 11 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: EF-1 thru 4 Model: GPI-46-G12 44.50 44.50 Model: GPI Roof Curb 12.00 Tags: EF-1 EF-2 EF-3 EF-4 48.50 48.50 Standard Construction Features: - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure - Constructed of either 18 ga galvanized steel or 0.064 in. aluminum - Straight Sided without a cant - 2 in. mounting flange - 3 lb density insulation - Height - Available from 12 in. to 42 in. as specified in 0.5 in. increments. Notes: - The maximum roof opening dimension should not be greater than the "Actual" top outside dimension minus 2 in.. - The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. - The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. - Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. General Sizing Undersizing Weight Shipped Tag Qty Model Method (in.) (lb) Assembled Union Label No 4 GPI-46 Nominal 1.5 44 Yes Preference Dimensions Nominal Nominal Actual Actual Actual Actual Hinge Hinge Curb Outside Outside Outside Outside Inside Inside Base Base Height Width Length Width Length Width Length Width* Length* (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) (in.) 12 46 46 44.5 44.5 41 41 45 45 *May not be applicable Accessories Security Insulation Insulation Material Bars Liner (in.) R Value Galvanized No No 1 R4.3 Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 12 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: Intake Hood Model: FGI Model: FGI Standard Construction Features: -Precision formed locked rib construction. -Available in aluminum or galvanized steel construction. -0.5 in. galvanized steel mesh birdscreens. -Heavy gauge galvanized steel support members. -Hood can be removed completely from the base or hinged open. -Units with a throat size exceeding 60 in. x 120 in. will have 12 in. galvanized bases as standard. -Recommended roof opening dimension is at least 2.5 in. larger than the damper size. Dimensions Throat Throat Hood Hood Hood Curb Cap Curb Cap Width Length Width Length Height Width Length Weight Ship ID# Tag Qty Model TW (in.) TL (in.) A (in.) B (in.) C (in.) (in.) (in.) (lb) Assembled 6-1 4 FGI-60x60 60 60 100 108 29.5 66 66 394 No Performance Throat Volume Throat AreaVelocity (ft/ ID# Tag Qty (CFM) SP (in. wg) (ft2) min) 6-1 4 15,000 0.085 25 600 Construction Installation Insect Base Birdscreen Unit ID# Type Screen Height (in.) Material Material 6-1 Non-Ducted No 5 Galvanized Galvanized Accessories Texas Department of Florida Insurance Hood Supply High Wind Product Miami-Dade Product Insulation Tie Down ID# Filters Rated Approval # NOA# Evaluation Curb Seal (in.) Points 6-1 No No N/A N/A N/A No None No Roof Curbs Height Width Length ID# Model (in.) (in.) (in.) 6-1 GPI 12 66 66 Dampers Width Length Blade Frame Actuator Actuator End Damper ID# Model (in.) (in.) Action Type Actuator Type Quantity Mounting Switch Mounting 6-1 VCD-23 60 60 Parallel Channel 24 VAC 1 Internal No Ship Separate Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 13 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: Intake Hood Model: FGI Standard Construction Features: Control Damper Model: VCD-23 - Model VCD-23 is a well built low leakage control damper for automatic control or manual balancing applications - Galvanized 16 ga channel frame - Galvanized blades with reinforcements - Side mounted steel linkage is concealed in the frame to prevent additional pressure drop - Axles are steel and 0.5 in. dia.- Synthetic axle bearings - Width and height furnished approximately 0.25 in. undersized - Field wiring is required to individual components Damper Configuration: ID #: Tag: Quantity: W (in.): H (in.): Act Qty: 6-1 4 60 60 1 Notes: All dimensions shown are in units of in. Width And height furnished approximately 0.25 in. undersize Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 14 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Mark: Intake Hood Model: GPI Model: GPI Roof Curb Standard Construction Features: - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure - Constructed of either 18 ga galvanized steel or 0.064 in. aluminum - Straight Sided without a cant - 2 in. mounting flange - 3 lb density insulation - Height - Available from 12 in. to 42 in. as specified in 0.5 in. increments. Notes: - The maximum roof opening dimension should not be greater than the "Actual" top outside dimension minus 2 in.. - The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. - The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. - Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. General Sizing Undersizing Weight Shipped ID# Tag Qty Model Method (in.) (lb) Assembled Union Made 6-1 No 4 GPI-66-G12 Nominal 1.5 77 Yes Preference Dimensions Nominal Nominal Actual Actual Curb Outside Outside Outside Outside Height Width Length Width Length ID# (in.) (in.) (in.) (in.) (in.) 6-1 12 66 66 64.5 64.5 *May not be applicable Accessories Security Insulation Insulation ID# Material Bars Liner (in.) R Value 6-1 Galvanized No No 1 R4.3 Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 15 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Roof Curb Standard Construction Features: Model: GPI - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure - Constructed of either 18 ga galvanized steel or 0.064 in. aluminum - Straight Sided without a cant - 2 in. mounting flange - 3 lb density insulation - Height - Available from 12 in. to 42 in. as specified in 0.5 in. increments. Notes: - The maximum roof opening dimension should not be greater than the "Actual" top outside dimension minus 2 in.. - The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. - The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. - Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. Roof Curb Configuration: ID #: Tag: Qty: Curb Cap W x L: Actual W x L: Flange W: Flange L: Height: Step Hgt: Damper Tray W x L: 9 (Multiple) 4 46 x 46 44.5 x 44.5 48.5 48.5 12 N/A x 15 Intake Hood 1 66 x 66 64.5 x 64.5 68.5 68.5 12 N/A x Notes: All dimensions shown are in units of in. Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 16 of 17 Printed Date: 07/26/2024 Job: Tenant 48 Warehouse Control Damper Standard Construction Features: Model: VCD-23 - Model VCD-23 is a well built low leakage control damper for automatic control or manual balancing applications - Galvanized 16 ga channel frame - Galvanized blades with reinforcements - Side mounted steel linkage is concealed in the frame to prevent additional pressure drop - Axles are steel and 0.5 in. dia.- Synthetic axle bearings - Width and height furnished approximately 0.25 in. undersized - Field wiring is required to individual components Damper Configuration: ID #: Tag: Quantity: W (in.): H (in.): Act Qty: Actuator Model: 9 (Multiple) 4 40 40 1 FSNF24 15 Intake Hood 1 60 60 Notes: All dimensions shown are in units of in. Width And height furnished approximately 0.25 in. undersize Z:\Matt\Greenheck CAPS\Jobs\Tenant 48 Warehouse.gfcj CAPS 4.44.1078 Generated by: matt@dorse.com Page 17 of 17 Technical data sheet 22G0214-5.. Gas monitor Belimo gas monitors are factory calibrated and can monitor up to two gases simultaneously. All monitors feature audible and visual alarms and CAN bus communication, allowing for standalone operation and networking of up to 32 devices. Select models feature relays and analog outputs to control ventilation directly, as well as BACnet MS/TP allowing for integration into a BMS. All gas monitors are wired via a daisy chain and are backed by a five-year warranty. Type Overview Type Measured values Number of relays Number of analog outputs Communication 22G0214-5A CO, NO₂ 1 2 CAN bus, BACnet MS/TP 22G0214-5B CO, NO₂ 2 0 CAN bus, BACnet MS/TP 22G0214-5C CO, NO₂ 0 0 CAN bus Technical data Electrical Data Nominal voltage AC/DC 24 V Nominal voltage note Please see the remarks section for nominal voltage details and nominal voltage range. Nominal voltage frequency 50/60 Hz Power consumption AC 5 VA Power consumption DC 1.7 W Cable entry 2 top, 2 bottom, 1 rear – 1/2" EMT Cable specification Power cable: 18...20 AWG Communication cable: 22...24 AWG twisted pair, shielded jacketed, low capacitance Please see the remarks section for more information about cable size and polarity. Fuse Thermal PTC, auto-reset Data bus communication Communication CAN bus BACnet MS/TP www.belimo.com 22G0214-5.. • en-us • 2024-05-09 • Subject to change 1 / 8 Technical data sheet 22G0214-5.. Functional Data Application Air Output signal active note Analog outputs: 2...10 V or 4...20 mA, user selectable with jumper Output signal relay note Relays: SPDT, 5A @ AC 125 V, non-inductive Please see Remarks section for relay rating. Mounting Please see installation notes section for mounting height recommendations. Max. altitude 6562 ft [2000 m] above sea level Max. altitude note Calibration verification is recommended above 2000 ft [610 m] Coverage area Radius: 15 m [50 ft] Area: 700 m² [7500 ft²] There can be no obstructions such as walls, elevators, stairs, shelving with solid fill, tool chests, etc. Otherwise the time weighted average (TWA) for the gas to reach the monitor will increase. Display LCD with backlight showing gas type, gas concentration, alarm level status Alarm Alarm level 1: Visual alarm (red LED) Alarm level 2: Visual alarm (red LED) Alarm level 3: Visual and audible alarm (flashing white strobe LED and horn) Horn: 80 dB @ 1 m [3.3ft] Warm-up time 5 minutes Measuring Data Measured values CO NO₂ Specification gas Sensing element technology Electro-chemical Measuring range CO: 0...250 ppm NO₂: 0...10 ppm Accuracy CO: ±3% FS from 0...75 ppm @ 23.5°C [74°F] NO₂: 0...6.5% FS from 0…2 ppm @ 23.5 °C [74°F] FS: Full scale of the measuring range Please see the remarks section for more information about the accuracy of CO and NO₂ sensors. Measurement repeatability <+3% CO equivalent <+2% NO₂ equivalent Long term stability CO: <5% per year NO₂: <2% per month Calibration Non-interactive zero and span Sensor modules are required to be calibrated annually. Typical response time <30 s (T90) Specification Temperature Measuring range -4...122°F [-20...50°C] Please see the remarks section for the application notice for temperature sensor www.belimo.com 22G0214-5.. • en-us • 2024-05-09 • Subject to change 2 / 8 Technical data sheet 22G0214-5.. Technical data Specification Temperature Accuracy temperature passive ±7°C @ 23.5°C [13°F @ 74°F] Please see the Remarks section under Application Notice for more information about temperature accuracy Safety Data Degree of protection IEC/EN IP44 Degree of protection NEMA/UL NEMA 2 Agency Listing cULus listed to UL2075, ULC-S588 cCSAus listed to C22.2 No. 61010-1-12, UL Std. No. 61010-1 (3rd Edition), harmonized under IEC/EN 61010-1 BTL listed No. BTL-30001 Pollution degree 2 Ambient humidity 15…90% RH continuous, 0…99% RH intermittent, non-condensing Ambient temperature -4...122°F [-20...50°C] Materials Housing UL94 5VA Remarks Nominal voltage details All Belimo gas monitors, communication modules, and relay units can be powered by AC/DC 24 V. Under CSA/UL 61010-1 all gas monitors and communication modules are rated to AC 24 V only. Under ULC-S588 and UL 2075, all vehicle emissions gas monitors (CO, NO₂, CO + NO₂) are rated to AC/DC 24 V. Nominal voltage range All Belimo gas monitors, communication modules, and relay units have a nominal voltage range of AC 17…28/DC 21…38 V (not UL or CSA-tested), AC/DC 20.4…26.4 V (UL-tested). Power cable size and polarity Terminal blocks can accommodate one 14...20 AWG wire, or two 18...20 AWG wires in the same terminal. Please take cable and transformer size into account to provide adequate voltage. Maintain the same polarity between devices at full power (AC/DC 24 V). Communication cable size and polarity CAN bus and BACnet MS/TP communication cables should be 22…24 AWG, twisted-pair, shield-jacketed, low-capacitance. Please consider the CAN bus baud rate (programmable setting No. 68) and BACnet the MS/TP baud rate (programmable setting No. 48) to provide working communications. For all communication wiring, maintain the same polarity and baud rate between all devices on the network. Relay rating All relays used in Belimo gas monitors, communication modules, and relay units are rated for: SPDT, 5 A @ AC 125 V, non-inductive (UL/CSA tested), and SPDT, 4 A @ DC 24 V, non-inductive (not UL/CSA tested). Application notice for temperature sensor All Belimo gas monitors and communication modules come with an internal temperature sensor. The purpose of this temperature sensor is to protect an enclosed parking garage from overheating or freezing, by activating relay 1. When using this feature, it is recommended to calibrate the temperature sensor to the ambient temperature (programmable setting No. 50), after the gas monitor has been powered for 24 hours. For freeze protection, it is recommended to set the temperature set point (programmable settings No. 55) at or over 40 °F [4°C]. Please note that this temperature sensor is located on the gas monitor printed circuit board (PCB). Therefore, it needs to be calibrated after 24 hours of normal operation to offset the heat generated by the PCB. It is not intended to be used as a room temperature sensor because of the limited accuracy and slow response time caused by its location on the PCB. This temperature sensor accuracy of ±13°F @ 74°F [7°C @ 23.5°C] has not been certified by UL. www.belimo.com 22G0214-5.. • en-us • 2024-05-09 • Subject to change 3 / 8 Technical data sheet 22G0214-5.. Remarks Accuracy for gas monitors CO and NO₂ sensor accuracies are not certified by UL. Both accuracies were internally tested and validated in an environmental chamber and compared to a high-accuracy reference device (analyzer). Application notice for gas sensors Intended applications include residential, light commercial, and light industrial. Non-intended applications include heavy commercial, heavy industrial, or hazardous locations. Vehicle emissions (CO, NO2): Enclosed parking garages, loading docks, automotive maintenance facilities, truck maintenance facilities, fire stations, ambulance bays, boiler rooms, warehouses Installation notes Mounting height recommendations CO mounting height recommendations in an enclosed parking garage are the same regardless of the types of vehicles being stored and the height of the parking garage. NO₂ mounting height recommendations in an enclosed parking garage are dependent on the types of vehicles being stored there and the ceiling height of the parking garage. If a parking garage ceiling is higher than 4.5 m [15 ft], then that is a good indicator that larger-sized vehicles such as trucks and heavy equipment will be stored there. Because a majority of larger vehicles have diesel engines, which release NO₂ as a byproduct, and have their exhaust released from above the vehicle, we recommend mounting NO₂ monitors at half of the ceiling height, and/or above the diesel exhaust, and mounting CO monitors to at 0.9...2.1 m [3...7 ft] from the floor. The ideal location for CO is 1.5 m [5 ft]. When the monitor is mounted at the correct height, it is less likely to be damaged by passing cars and trucks, and it is in a good location to be serviced. For these applications. we offer a high/low kit (A-22G-A14) that allows the installer to place the gas monitor at 0.9...2.1 m [3...7 ft] above the floor to monitor CO, and place the high/low kit at half of the ceiling height and above the diesel exhaust, for remote NO₂ monitoring. An RJ45 cable runs from the gas monitor to the high/low kit to connect the two. If a parking garage ceiling is lower than 4.5 m [15 ft], then that is a good indicator that larger- sized vehicles will not be stored there. In these applications we recommend that CO and NO₂ be monitored at 0.9...2.1 m [3...7 ft] from the floor. Again, the ideal location is 1.5 m[5 ft]. In these applications, we recommend monitoring CO and NO₂ at the same height. Accessories Replacement sensor modules Description Type Sensor module CO (Carbon Monoxide), 0...250 ppm, R-G02 Sensor module NO₂ (Nitrogen Dioxide), 0...10 ppm, R-G14 Electrical accessories Description Type Communication module, CAN bus, BACnet MS/TP, 1 relay, 2 analog C-22G-5A outputs Communication module, CAN bus, BACnet MS/TP, 2 relays C-22G-5B Communication module, CAN bus C-22G-5C Relay unit, CAN bus, 4 relays C-22G-50 High-low mounting kit A-22G-A14 External visual alarm A-22G-A15 External audible alarm A-22G-A16 Transformer, 50 VA A-22G-A50 Transformer, 100 VA A-22G-A100 Mechanical accessories Description Type Splash proof enclosure A-22G-A12 Duct mount enclosure A-22G-A13 Calibration kit, A-22G-A22 www.belimo.com 22G0214-5.. • en-us • 2024-05-09 • Subject to change 4 / 8 Technical data sheet 22G0214-5.. Wiring Diagram A Model Wiring B Model Wiring www.belimo.com 22G0214-5.. • en-us • 2024-05-09 • Subject to change 5 / 8 Technical data sheet 22G0214-5.. C Model Wiring 1 Analog outputs Down position: 2....10 V (factory setting) Up position: 4...20 mA 2 End of line (EOL) jumper: CAN bus Down position: Termination OFF (factory setting) Up position: Termination ON (first and last unit only should have this jumper in the up position) 3 End of line (EOL) jumper: MS/TP Down position: Termination OFF (factory setting) Up position: Termination ON (first and last unit only should have this jumper in the up position) 4 Relay output 5 Analog output 6 Shield connected at the first unit only, at others only looped through 7 Binary input to limit switch 8 Shield connected at the first unit only, at others only looped through 9 No connection to the ground www.belimo.com 22G0214-5.. • en-us • 2024-05-09 • Subject to change 6 / 8 Technical data sheet 22G0214-5.. Wiring CAN bus CAN bus Wiring Wiring Diagram Wiring RS485 BACnet MS/TP BACnet MS/ TP Wiring www.belimo.com 22G0214-5.. • en-us • 2024-05-09 • Subject to change 7 / 8 Technical data sheet 22G0214-5.. Dimensions Type Weight 22G0214-5A 0.99 lb [0.45 kg] 22G0214-5B 0.99 lb [0.45 kg] 22G0214-5C 0.99 lb [0.45 kg] Further documentation • Installation instructions • Operating instructions www.belimo.com 22G0214-5.. • en-us • 2024-05-09 • Subject to change 8 / 8 ABBREVIATIONS PLAN SYMBOLS GENERAL HVAC NOTES G A Ø DIAMETER N W CEILING SUPPLY DIFFUSER 1. COMPLETE INSTALLATION OF MECHANICAL SYSTEMS SHALL MEET APPLICABLE CODES PER 2018 IBC, 2018 EI , AFF ABOVE FINISHED FLOOR E AHU AIR HANDLING UNIT WASHINGTON STATE MECHANICAL CODE, & 2018 WASHINGTON STATE ENERGY CODE. L O BHP BRAKE HORSEPOWER CEILING RETURN GRILLE 2. VENTILATION BY MECHANICAL OR NATURAL MEANS SHALL BE NO GREATER THAN 150 PERCENT OF THE O RN BDD BACKDRAFT DAMPER MINIMUM OA REQUIRED PER WSEC C403.2.2. O BPD BY-PASS DAMPER O BTU/H BRITISH THERMAL UNIT PER HOUR CEILING EXHAUST GRILLE 3. All EQUIPMENT SPECIFIED THE SMALLEST SIZE THAT EXCEEDS THE CALCULATED LOADS PER WSEC area of work IS M C CONDENSATE DRAIN PIPING C CD CEILING DIFFUSER C403.3.1. CFM CUBIC FEET PER MINUTE FLEX DUCT AHU-1 (18K)TO ROOF. EF-2 TO NEAREST CONDENSATE 1 4. SYSTEM CONTROLS TO MEET ALL APPLICABLE SECTIONS UNDER SEC C403.4 OF 2018 WSEC. T DRAIN.. C& DB DECIBAL NOT IN SCOPE 2 S S S DH DUCT HEATER CEILING EXHAUST FAN 5. THERMOSTATS SHALL BE SET TO MAINTAIN A MINIMUM DEADBAND OF 5°F PER WSEC C403.4.1.2. 2 2 DOAS DEDICATED OUTDOOR AIR SYSTEM 6. CONTROLS TO BE EQUIPPED WITH AUTOMATIC TIME CLOCK CAPABLE OF STARTING AND STOPPING THE G 55 EER ENERGY EFFICIENCY RATIO 3 3 E 4 INLINE EXHAUST FAN MD MD N IAH-1 IAH-2 EG EXHAUST GRILLE SYSTEM WITH MANUAL OVERRIDE PER WSEC C403.4.2.2. (ON ROOF) (ON ROOF) I 1 ESP EXTERNAL STATIC PRESSURE MD MD EF-1 EF-4 7. ALL ECONOMIZERS PROVIDED SHALL MEET SEC C403.5 OF 2018 WSEC AND BE ABLE TO PROVIDE UP TO (ON ROOF) (ON ROOF) 84' 41'-8" EXH EXHAUST 41'-8" X EXHAUST FAN UP CF-1 CF-2 T O 100 PERCENT OSA FOR COOLING PER WSEC C403.5.3.1. FCU FAN COIL UNIT R 4 T B S S A 2 FD FIRE DAMPER 8. OUTDOOR AIR SUPPLY, EXHAUST OPENING, RELIEFS TO BE PROVIDED WITH CLASS 1 MOTORIZED DAMPER 2 . FPM FEET PER MINUTE ROUND DUCT UP E EF-2 (ON ROOF) FSD FIRE AND SMOKE DAMPER AND CLOSE DURING UNOCCUPIED EQUIPMENT OPERATION PER WSEC C403.7.8.1. IF GRAVITY DAMPER, IT MD MD .O EF-3 (ON ROOF) A A M1.0 M1.0 PH P GF GAS FURNACE SHALL HAVE AN AIR LEAKAGE RATE NOT GREATER THAN 20 CFM/FT^2. ROUND DUCT DOWN GRD GRILLE, REGISTER, DIFFUSER 2 2 9. SMOKE DETECTORS INSTALLED IN MAIN RETURN PER SEC 606 OF THE 2018 IMC. S S HP HORSEPOWER, HEAT PUMP HRU HEAT RECOVERY UNIT VAV FAN BOX 10. DUCTS TO BE SUPPORTED AT EACH CHANGE IN DIRECTION, VERTICAL AT 12'-0" MAX, HORIZONTAL AT 10'-0" HVAC HEATING VENTILATION & AIR CONDITIONING MAX WITH STRAP, OR 8'-0" MAX FROM TRAPEZE SUPPORT ID INSIDE DIMENSION BALANCE DAMPER (MANUAL) 11. DUCT INSULATION AND SEALING TO MEET REQUIREMENTS OF SEC C403.10.1 OF THE 2018 WSEC. IECC INTERNATIONAL ENERGY CONSERVATION CODE IFR INFRARED HEATER 12. ALL PIPING TO BE INSULATED ACCORDING TO SECTION C403.10.3 OF 2018 WSEC. IMC INTERNATIONAL MECHANICAL CODE GD GRAVITY DAMPER IN INCH 13. GAS PIPING TO BE INSTALLED IN ACCORDANCE WITH THE 2018 IFGC TABLE C404.6 WHEN APPLICABLE. ISP INTERNAL STATIC PRESSURE FSD FIRE SMOKE DAMPER 14. FLEXIBLE INSULATED DUCTS SHALL BE MAXIMUM 5'0" LONG AND STALL MEET INSTALLATION AND LB POUND LVR LOUVER MATERIAL REQUIREMENTS OF LOCAL CODES. MCA MINIMUM CIRCUIT AMPACITY M MOTORIZED DAMPER 15. 2018 SMC SECTION 603.4 METALLIC DUCTS. METALLIC DUCTS SHALL BE CONSTRUCTED AS SPECIFIED IN MAN/D MANUAL DAMPER THE SMACNA HVAC DUCT CONSTRUCTION STANDARDS—METAL AND FLEXIBLE. MECH MECHANICAL MIN MINIMUM ZONE DAMPER 16. 603.6.1 FLEXIBLE AIR DUCTS. FLEXIBLE AIR DUCTS, BOTH METALLIC AND NONMETALLIC, SHALL BE TESTED MOCP MAXIMUM OVERCURRENT PROTECTION MO/D MOTORIZED DAMPER IN ACCORDANCE WITH UL 181. SUCH DUCTS SHALL BE LISTED AND LABELED AS CLASS 0 OR CLASS 1 N SITE PLAN VICINITY MAP FIRE DAMPER ABOVE DIFFUSER N NC NOISE CRITERIA FLEXIBLE AIR DUCTS AND SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 304.1. NOM NOMINAL NO. NUMBER 17. ALL SUPPLY GRILLES TO HAVE MANUAL VOLUME DAMPERS FOR BALANCING OF SYSTEM UPON NTS NOT TO SCALE FIRE DAMPER ABOVE GRILLE COMPLETION. OA OUTSIDE AIR AIR VOLUME REFERENCE PROPERTY DETAILS SHEET INDEX OBD OPPOSED BLADE DAMPER T THERMOSTAT 18. HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF 408 IN 2018 WSEC HAVE BEEN ODD OUTSIDE DIMENSION OF DIAMETER SATISFIED, INCLUDING AS-BUILT DRAWINGS, SUBMITTALS, O&M MANUALS, BALANCE REPORT, AND ODU OUTDOOR UNIT 6" Ø - 0 TO 90 CFM TENANT: TENANT 48 M0.0 HVAC GENERAL NOTES S SENSOR COMMISSIONING REPORT. POC POINT OF CONNECTION 8" Ø - 90 TO 180 CFM PSI POUNDS PER SQUARE INCH 19. ALL HVAC EQUIPMENT TO BE LABELED FOR THE SPACE SERVED. M1.0 FIRST FLOOR MECHANICAL PLAN M GAS METER 10"Ø - 180 TO 350 CFM LAND OWNER: CITY OF ARLINGTON R REFRIGERATION LINES 20. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON SITE FOR INSPECTORS. M2.0 ROOF MECHANICAL PLAN RA RETURN AIR 12"Ø - 350 TO 550 CFM RCP REFLECTED CEILING PLAN SM 21. MEP DRAWINGS ARE NOT STRUCTURAL ENGINEERING DRAWINGS. WHERE STRUCTUREAL ENGINEERING IS RG RETURN GRILLE SMOKE DETECTOR REQUIRED, IT WILL BE BY OTHERS. 14"Ø - 550 TO 850 CFM PARCEL NO. 31052100400300 RPM REVOLUTIONS PER MINUTE RTU ROOFTOP UNIT 16"Ø - 850 TO 1350 CFM SD-# SUPPLY DIFFUSER SD SUPPLY DIFFUSER 18"Ø - 1350 TO 1750 CFM PROPERTY DESCRIPTION: SL SOUND LINED SP STATIC PRESSURE RG-# RETURN GRILLE SECTION 21 TOWNSHIP 31 RANGE 05 QUARTER SE LOT B CITY ARL BSP PLN#942 REC AFN SM/D SMOKE DAMPER P-TRAP DETAIL *USE ABOVE UNLESS OTHER SIZE IS 202206075002 BEING A PTN SE1/4 SE1/4 SD SEC LESS BLDGS ONLY ON 31052100400301 TG TRANSFER GRILLE TSTAT THERMOSTAT EF-# EXHAUST FAN INDICATED ON PLANS 3/4" CAP for cleanout TYP TYPICAL (DO NOT GLUE) VAV VARIABLE AIR VOLUME TG-# SITE AREA: 8.16 ACRES BUILDING AREA: 168,494 SF source elevation level TRANSFER GRILLE 3/4" CONDENSATE pipe VFD VARIABLE FREQUENCY DRIVE 3/4" OPEN PIPE ABOVE VTR VENT TO ROOF UNION TEE source elevation level USE CODE: 637 WAREHOUSING & STORAGE SERVICES WSEC WASHINGTON STATE ENERGY CODE - C - CONDENSATE LINE TO DRAIN ZD ZONE DAMPER 1" min. - R - REFRIDGERATION LINES SCOPE OF WORK: EQUIPMENT TEE 3" MIN. or 1. PROVIDE AND INSTALL 1 2 TR. WALL MOUNTED UNIT FOR EXISTING SERVER ROOM. mnfr req. 2. PROVIDE AND INSTALL 4 EXHAUST FANS AND 4 OUTDOOR AIR INTAKE HOODS. trap drain must be lower than source 3. PROVIDE AND INSTALL 2 CEILING FANS. 2" MIN. indoor UNIT SCHEDULE IDENTIFIER PERFORMANCE ELECTRICAL SPECIFICATIONS CAPACITY (BTU/H) design REFER SIZES SOUND DIMENSIONS TAG MAKE MODEL POWER SUPPLY MCA (A) WEIGHT NOTES cooling airflow (LIQUID/SUCTION) DBA ( W X H X D) AHU-1 carrier 40mahbq24xa3 24000 611 3/8 / 5/8 44 208/230-1-60 .625 44.88 X 14.57 X 10.83 43 .65 LBS 1 1. power for indoor unit (ahu-1) is fed from outdoor unit (hp-1). OUTDOOR HEAT PUMP / CONDENSER SCHEDULE IDENTIFIER PERFORMANCE ELECTRICAL CAPACITY REFER SIZES SOUND POWER MCA / MOCP DIMENSIONS (IN) TAG MAKE MODEL REFER TYPE WEIGHT NOTES (BTU/H) (LIQUID/SUCTION) DBA SUPPLY (A) (W X H X D) HP-1 CARRIER 38MARBQ24AA3 24000 R-410A 3/8 / 5/8 62 208/230-1-60 25 / 35 37.24 X 31.89 X 16.14 134.48 LBS exhaust fan SCHEDULE IDENTIFIER PERFORMANCE ELECTRICAL specifications TENANT 48 2.017216 51ST AVENUE NE ARLINGTON, WA 98223 external INSTALL design SOUND POWER DIMENSIONS APPROX. TAG MAKE MODEL static MCA / MOPD NOTES LOCATION cfm (sones) SUPPLY (Ø X H) WEIGHT pressure ef-1,2,3,4 GREEN HECK GB-330-VG-50 ROOF 15000 .4 25 460/60/3 9/ 20 58.8 X 50.5 385 1,2 1. FAN opertaion TO BE CONTROLLED BY co/no SENSORS. 2. provide motorized damper. CEILING fan SCHEDULE IDENTIFIER PERFORMANCE ELECTRICAL specifications external INSTALL design SOUND POWER MOTOR SIZE DIMENSIONS APPROX. TAG MAKE MODEL static FLA (aMPS) INPUT POWER(w) STANDBY POWER NOTES LOCATION cfm (DBA) SUPPLY (W) (Ø IMPELLER) WEIGHT pressure Cf-1,2 GREEN HECK DS-3-24-70HV CEILING 89400 - 31 460/60/3 500 2.5 128 13 288 213 1 # INTAKE AIR HOOD SCHEDULE REVISIONS1. 12/17/2024 - EF-1,4 & CF-1,2 LOCATIONS CHANGED 2. 01/15/2025 CF-1 & CF-2 LOCATIONS CHANGED3. 4. 5. 6. 7. 8. IDENTIFIER PERFORMANCE DIMENSIONS SPECIFICATIONS INSTALL design static HOOD APPROX. TAG MAKE MODEL THROAT CURB CAP NOTES LOCATION cfm pressure (L X W X H) WEIGHT IAH- 1,2,3,4 GREEN HECK FGI ROOF 15000 .085 60 X 60 108 X 100 X29.5 66 X 66 394 1,2 11/04/20241/15/2025 1. PROVIDE GALVANIZED BIRDSCREEN-0.5 IN MESH TYPE. 2.provide motorized dampers. dampers to be interlocked with individual fans. K.S.B MECHANICAL PLANSSTART DATE:PRINT DATE:DRAWN BY: M0.0 SHEET G A N W EI , # MECHANICAL NOTES = E L O R 1. EXISTING EXHAUST FAN. SET FAN THERMOSTAT TO 90 DEG F. O N 2. CO/NO SENSORS TO BE INTERLOCKED WITH ROOF EXHAUST FANS. ISO O 3. 60" X 60 " INTAKE AIR HOOD ON ROOF. PROVIDE MOTORIZED DAMPER. C M 4. CF-1 AND CF-2 TO BE CONTROLLED BY SINGLE TOUCHSCREEN CONTROL. 5. Final loaction for installation to be verified on site. C& G 5 9'-9" E 54 EF-2 N (EXISTING) TO ROOF. I 1 AHU-1 (24K) X SERVER T 109 RA OB 1 T TO NEAREST . E CONDENSATE .O DRAIN. PH P NOT IN SCOPE S S 2 2 3 3 MD MD IAH-1 IAH-2 (ON ROOF) (ON ROOF) 2 4 S T EF-1 EF-4 (ON ROOF) (ON ROOF) MOUNTED ON EXISTING MD 5 MD I BEAM CF-1 42.0 288 3.0 5 CF-2 DETAIL B (TYP.) EXISTING I BEAM B B M1.0 M1.0 SCALE:1/8" - 1-0' 2 S S S 2 2 3 3 EXISTING. EF MD MD ROOF TENANT 48 2.017216 51ST AVENUE NE ARLINGTON, WA 98223 EF-2 (ON ROOF) IAH-3 IAH-4 MD MD (ON ROOF) (ON ROOF) 40 X 40 EF-3 A A (ON ROOF) M1.0 M1.0 SECURE DUCTWORK 50 X 25 2 TO WALL. S # 40 X 40 SCREENED OPENING. 24" ABOVE FFL. REVISIONS1. 12/17/2024 - EF-1,4 & CF-1,2 LOCATIONS CHANGED 2. 01/15/2025 CF-1 & CF-2 LOCATIONS CHANGED3. 4. 5. 6. 7. 8. DETAIL A (TYP.) 1st FLOOR MECHANICAL PLAN 11/04/20241/16/2025 SCALE:1/8" - 1-0' SCALE: 3/32" = 1-0' K.S.B N MECHANICAL PLANSSTART DATE:PRINT DATE:DRAWN BY: M1.0 SHEET G A N W EI , E # MECHANICAL NOTES = L O R O N 1. EXISTING EXHAUST FAN. SET FAN THERMOSTAT TO 90 DEG F. O O 2. CO/NO SENSORS TO BE INTERLOCKED WITH ROOF EXHAUST FANS. IS M 3. 60" X 60 " INTAKE AIR HOOD ON ROOF. PROVIDE MOTORIZED DAMPER. C 4. CF-1 AND CF-2 TO BE CONTROLLED BY SINGLE TOUCHSCREEN CONTROL. 5. Final loaction for installation to be verified on site. C& G 5 5 HP-1 EN 4 I 1 X 5 RT O A B . E .O PH P IAH-1 IAH-2 5 5 5 5 EF-1 EF-4 5 5 IAH-3 IAH-4 TENANT 48 2.017216 51ST AVENUE NE ARLINGTON, WA 98223 5 5 EF-2 EF-3 # REVISIONS1. 12/17/2024 - EF-1,4 & CF-1,2 LOCATIONS CHANGED 2. 01/15/2025 CF-1 & CF-2 LOCATIONS CHANGED3. 4. 5. 6. 7. 8. ROOF MECHANICAL PLAN 11/04/20241/15/2025 SCALE: 3/32" = 1-0' K.S.B N MECHANICAL PLANSSTART DATE:PRINT DATE:DRAWN BY: M2.0 SHEET G E N E R A L N O T E S CODE: INTERNATIONAL BUILDING CODE, 2021 EDITION BUILDING RISK CATEGORY = II LIVE LOADS: UNIFORM LOADS: LOCATION LIVE LOAD REDUCIBLE ROOF 25 PSF (SNOW) NO WIND DESIGN INFORMATION: WIND LOADS ON THE MAIN WIND-FORCE RESISTING SYSTEM (MWFRS) WAS DETERMINED Digitally signed USING THE ENVELOPE PROCEDURE. WIND SPEED Vult = 98 MPH Vasd = 76 MPH EXPOSURE “C” by Carson SEISMIC DESIGN INFORMATION: Thompson SS = 1.06 SDS = 0.760 S1 = 0.378 SD1 = 0.479 Date: 2024.12.18 IE = 1.0 SITE SOIL CLASS = D, SEISMIC DESIGN CATEGORY = D 14:28:34 -08'00' STRUCTURAL STEEL: ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 (Fy = 36,000 psi) OR ASTM A992 GRADE 50 (Fy = 50,000 psi). APPLY PRIMER COATS PER ARCHITECTURAL SPECIFICATIONS. WELDS NOT SPECIFIED SHALL BE 3/16" CONTINUOUS FILLET MINIMUM. ALL WELDS TO BE IN ACCORDANCE WITH AWS D1.1 AND D1.8, AND BY WABO CERTIFIED WELDERS. USE FRESH E70XX LOW HYDROGEN ELECTRODES. ALL STRUCTURAL WELDS SHOULD BE CONSIDERED PART OF THE SEISMIC FORCE RESISTING SYSTEM AND SHALL BE MADE WITH FILLER METAL PRODUCING WELDS WITH A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20 FT-LBS AT 0 DEGREES-F AS DETERMINED BY THE APPLICABLE AWS A5 CLASSIFICATION TEST METHOD. SHUTLER CONSULTING ENGINEERS Inc. SPECIAL INSPECTIONS: SPECIAL INSPECTIONS PER IBC SECTION 1705. A COPY OF ALL INSPECTION REPORTS AND TEST RESULTS FOR ALL REQUIRED INSPECTIONS SHALL BE SUBMITTED TO THE BUILDING (425) 450-4075 DEPARTMENT, SHUTLER CONSULTING ENGINEERS, THE OWNER AND THE ARCHITECT BY THE TESTING AGENCY FOR REVIEW. THE TESTING AGENCY SHALL BE AN INDEPENDENT TESTING Bellevue, Washington 98005 AGENCY APPROVED BY THE BUILDING DEPARTMENT. 12503 Bel-Red Road, Suite 100 SPECIAL CONDITIONS: 2024 THE DRAWINGS INDICATE THE STRUCTURE IN ITS FINAL CONDITION. DURING C CONSTRUCTION THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING, BRACING, AND All rights reserved. No part of this document may be reproduced, in any form or by any means, without permission in writing from Shutler Consulting Engineers, Inc. GUYING IN ACCORDANCE WITH SOUND PRACTICE AND ALL NATIONAL, STATE, AND LOCAL CODES. CONTRACTOR TO COORDINATE ALL TRADES AND VERIFY DIMENSIONS IN FIELD. MECHANICAL, FIRE PROTECTION AND ELECTRICAL SYSTEMS: IT SHALL BE THE GENERAL CONTRACTOR AND/OR SUB-CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL NECESSARY ENGINEERING AND CONSTRUCTION DOCUMENTS FOR THEIR SCOPE OF WORK. THIS SHALL INCLUDE THE DESIGN OF THEIR SYSTEM AND ANY REVIEW AND MODIFICATIONS OF THE BASIC STRUCTURAL SYSTEM SHOWN ON THESE CONSTRUCTION DOCUMENTS AS WELL AS ANY ADDITIONAL STRUCTURAL SUPPORT REQUIRED BY THEIR SYSTEM. PERMIT SET DATE DESCRIPTION 12-18-2024 HVAC 17216 51ST AVE NE TENANT 48 2.0 ARLINGTON, WASHINGTON 98223 GENERAL NOTES, PLAN & SECTIONS ENGINEER: CT CHECKED BY: JH DATE: 12-16-2024 JOB No.: 24-01.111 SHEET No.: S1.0 1 OF 1 K:\24\24-01 Miscellaneous\111 Tenant 48 2.0 - HVAC\0DWG\SHT-S1-0\SHT-S1-0.dwg, Model, 12/18/2024 2:28:05 PM, Carson, 1:1 ABBREVIATIONS PLAN SYMBOLS GENERAL HVAC NOTES G A Ø DIAMETER N W CEILING SUPPLY DIFFUSER 1. COMPLETE INSTALLATION OF MECHANICAL SYSTEMS SHALL MEET APPLICABLE CODES PER 2018 IBC, 2018 EI , AFF ABOVE FINISHED FLOOR E AHU AIR HANDLING UNIT WASHINGTON STATE MECHANICAL CODE, & 2018 WASHINGTON STATE ENERGY CODE. L O BHP BRAKE HORSEPOWER CEILING RETURN GRILLE 2. VENTILATION BY MECHANICAL OR NATURAL MEANS SHALL BE NO GREATER THAN 150 PERCENT OF THE O RN BDD BACKDRAFT DAMPER MINIMUM OA REQUIRED PER WSEC C403.2.2. O BPD BY-PASS DAMPER O BTU/H BRITISH THERMAL UNIT PER HOUR CEILING EXHAUST GRILLE 3. All EQUIPMENT SPECIFIED THE SMALLEST SIZE THAT EXCEEDS THE CALCULATED LOADS PER WSEC area of work IS M C CONDENSATE DRAIN PIPING C CD CEILING DIFFUSER C403.3.1. CFM CUBIC FEET PER MINUTE FLEX DUCT AHU-1 (18K)TO ROOF. EF-2 TO NEAREST CONDENSATE 1 4. SYSTEM CONTROLS TO MEET ALL APPLICABLE SECTIONS UNDER SEC C403.4 OF 2018 WSEC. T DRAIN.. C& DB DECIBAL NOT IN SCOPE 2 S S S DH DUCT HEATER CEILING EXHAUST FAN 5. THERMOSTATS SHALL BE SET TO MAINTAIN A MINIMUM DEADBAND OF 5°F PER WSEC C403.4.1.2. 2 2 DOAS DEDICATED OUTDOOR AIR SYSTEM 6. CONTROLS TO BE EQUIPPED WITH AUTOMATIC TIME CLOCK CAPABLE OF STARTING AND STOPPING THE G 55 EER ENERGY EFFICIENCY RATIO 3 3 E 4 INLINE EXHAUST FAN MD MD N IAH-1 IAH-2 EG EXHAUST GRILLE SYSTEM WITH MANUAL OVERRIDE PER WSEC C403.4.2.2. (ON ROOF) (ON ROOF) I 1 ESP EXTERNAL STATIC PRESSURE MD MD EF-1 EF-4 7. ALL ECONOMIZERS PROVIDED SHALL MEET SEC C403.5 OF 2018 WSEC AND BE ABLE TO PROVIDE UP TO (ON ROOF) (ON ROOF) 84' 41'-8" EXH EXHAUST 41'-8" X EXHAUST FAN UP CF-1 CF-2 T O 100 PERCENT OSA FOR COOLING PER WSEC C403.5.3.1. FCU FAN COIL UNIT R 4 T B S S A 2 FD FIRE DAMPER 8. OUTDOOR AIR SUPPLY, EXHAUST OPENING, RELIEFS TO BE PROVIDED WITH CLASS 1 MOTORIZED DAMPER 2 . FPM FEET PER MINUTE ROUND DUCT UP E EF-2 (ON ROOF) FSD FIRE AND SMOKE DAMPER AND CLOSE DURING UNOCCUPIED EQUIPMENT OPERATION PER WSEC C403.7.8.1. IF GRAVITY DAMPER, IT MD MD .O EF-3 (ON ROOF) A A M1.0 M1.0 PH P GF GAS FURNACE SHALL HAVE AN AIR LEAKAGE RATE NOT GREATER THAN 20 CFM/FT^2. ROUND DUCT DOWN GRD GRILLE, REGISTER, DIFFUSER 2 2 9. SMOKE DETECTORS INSTALLED IN MAIN RETURN PER SEC 606 OF THE 2018 IMC. S S HP HORSEPOWER, HEAT PUMP HRU HEAT RECOVERY UNIT VAV FAN BOX 10. DUCTS TO BE SUPPORTED AT EACH CHANGE IN DIRECTION, VERTICAL AT 12'-0" MAX, HORIZONTAL AT 10'-0" HVAC HEATING VENTILATION & AIR CONDITIONING MAX WITH STRAP, OR 8'-0" MAX FROM TRAPEZE SUPPORT ID INSIDE DIMENSION BALANCE DAMPER (MANUAL) 11. DUCT INSULATION AND SEALING TO MEET REQUIREMENTS OF SEC C403.10.1 OF THE 2018 WSEC. IECC INTERNATIONAL ENERGY CONSERVATION CODE IFR INFRARED HEATER 12. ALL PIPING TO BE INSULATED ACCORDING TO SECTION C403.10.3 OF 2018 WSEC. IMC INTERNATIONAL MECHANICAL CODE GD GRAVITY DAMPER IN INCH 13. GAS PIPING TO BE INSTALLED IN ACCORDANCE WITH THE 2018 IFGC TABLE C404.6 WHEN APPLICABLE. ISP INTERNAL STATIC PRESSURE FSD FIRE SMOKE DAMPER 14. FLEXIBLE INSULATED DUCTS SHALL BE MAXIMUM 5'0" LONG AND STALL MEET INSTALLATION AND LB POUND LVR LOUVER MATERIAL REQUIREMENTS OF LOCAL CODES. MCA MINIMUM CIRCUIT AMPACITY M MOTORIZED DAMPER 15. 2018 SMC SECTION 603.4 METALLIC DUCTS. METALLIC DUCTS SHALL BE CONSTRUCTED AS SPECIFIED IN MAN/D MANUAL DAMPER THE SMACNA HVAC DUCT CONSTRUCTION STANDARDS—METAL AND FLEXIBLE. MECH MECHANICAL MIN MINIMUM ZONE DAMPER 16. 603.6.1 FLEXIBLE AIR DUCTS. FLEXIBLE AIR DUCTS, BOTH METALLIC AND NONMETALLIC, SHALL BE TESTED MOCP MAXIMUM OVERCURRENT PROTECTION MO/D MOTORIZED DAMPER IN ACCORDANCE WITH UL 181. SUCH DUCTS SHALL BE LISTED AND LABELED AS CLASS 0 OR CLASS 1 N SITE PLAN VICINITY MAP FIRE DAMPER ABOVE DIFFUSER N NC NOISE CRITERIA FLEXIBLE AIR DUCTS AND SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 304.1. NOM NOMINAL NO. NUMBER 17. ALL SUPPLY GRILLES TO HAVE MANUAL VOLUME DAMPERS FOR BALANCING OF SYSTEM UPON NTS NOT TO SCALE FIRE DAMPER ABOVE GRILLE COMPLETION. OA OUTSIDE AIR AIR VOLUME REFERENCE PROPERTY DETAILS SHEET INDEX OBD OPPOSED BLADE DAMPER T THERMOSTAT 18. HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF 408 IN 2018 WSEC HAVE BEEN ODD OUTSIDE DIMENSION OF DIAMETER SATISFIED, INCLUDING AS-BUILT DRAWINGS, SUBMITTALS, O&M MANUALS, BALANCE REPORT, AND ODU OUTDOOR UNIT 6" Ø - 0 TO 90 CFM TENANT: TENANT 48 M0.0 HVAC GENERAL NOTES S SENSOR COMMISSIONING REPORT. POC POINT OF CONNECTION 8" Ø - 90 TO 180 CFM PSI POUNDS PER SQUARE INCH 19. ALL HVAC EQUIPMENT TO BE LABELED FOR THE SPACE SERVED. M1.0 FIRST FLOOR MECHANICAL PLAN M GAS METER 10"Ø - 180 TO 350 CFM LAND OWNER: CITY OF ARLINGTON R REFRIGERATION LINES 20. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON SITE FOR INSPECTORS. M2.0 ROOF MECHANICAL PLAN RA RETURN AIR 12"Ø - 350 TO 550 CFM RCP REFLECTED CEILING PLAN SM 21. MEP DRAWINGS ARE NOT STRUCTURAL ENGINEERING DRAWINGS. WHERE STRUCTUREAL ENGINEERING IS RG RETURN GRILLE SMOKE DETECTOR REQUIRED, IT WILL BE BY OTHERS. 14"Ø - 550 TO 850 CFM PARCEL NO. 31052100400300 RPM REVOLUTIONS PER MINUTE RTU ROOFTOP UNIT 16"Ø - 850 TO 1350 CFM SD-# SUPPLY DIFFUSER SD SUPPLY DIFFUSER 18"Ø - 1350 TO 1750 CFM PROPERTY DESCRIPTION: SL SOUND LINED SP STATIC PRESSURE RG-# RETURN GRILLE SECTION 21 TOWNSHIP 31 RANGE 05 QUARTER SE LOT B CITY ARL BSP PLN#942 REC AFN SM/D SMOKE DAMPER P-TRAP DETAIL *USE ABOVE UNLESS OTHER SIZE IS 202206075002 BEING A PTN SE1/4 SE1/4 SD SEC LESS BLDGS ONLY ON 31052100400301 TG TRANSFER GRILLE TSTAT THERMOSTAT EF-# EXHAUST FAN INDICATED ON PLANS 3/4" CAP for cleanout TYP TYPICAL (DO NOT GLUE) VAV VARIABLE AIR VOLUME TG-# SITE AREA: 8.16 ACRES BUILDING AREA: 168,494 SF source elevation level TRANSFER GRILLE 3/4" CONDENSATE pipe VFD VARIABLE FREQUENCY DRIVE 3/4" OPEN PIPE ABOVE VTR VENT TO ROOF UNION TEE source elevation level USE CODE: 637 WAREHOUSING & STORAGE SERVICES WSEC WASHINGTON STATE ENERGY CODE - C - CONDENSATE LINE TO DRAIN ZD ZONE DAMPER 1" min. - R - REFRIDGERATION LINES SCOPE OF WORK: EQUIPMENT TEE 3" MIN. or 1. PROVIDE AND INSTALL 1 2 TR. WALL MOUNTED UNIT FOR EXISTING SERVER ROOM. mnfr req. 2. PROVIDE AND INSTALL 4 EXHAUST FANS AND 4 OUTDOOR AIR INTAKE HOODS. trap drain must be lower than source 3. PROVIDE AND INSTALL 2 CEILING FANS. 2" MIN. indoor UNIT SCHEDULE IDENTIFIER PERFORMANCE ELECTRICAL SPECIFICATIONS CAPACITY (BTU/H) design REFER SIZES SOUND DIMENSIONS TAG MAKE MODEL POWER SUPPLY MCA (A) WEIGHT NOTES cooling airflow (LIQUID/SUCTION) DBA ( W X H X D) AHU-1 carrier 40mahbq24xa3 24000 611 3/8 / 5/8 44 208/230-1-60 .625 44.88 X 14.57 X 10.83 43 .65 LBS 1 1. power for indoor unit (ahu-1) is fed from outdoor unit (hp-1). OUTDOOR HEAT PUMP / CONDENSER SCHEDULE IDENTIFIER PERFORMANCE ELECTRICAL CAPACITY REFER SIZES SOUND POWER MCA / MOCP DIMENSIONS (IN) TAG MAKE MODEL REFER TYPE WEIGHT NOTES (BTU/H) (LIQUID/SUCTION) DBA SUPPLY (A) (W X H X D) HP-1 CARRIER 38MARBQ24AA3 24000 R-410A 3/8 / 5/8 62 208/230-1-60 25 / 35 37.24 X 31.89 X 16.14 134.48 LBS exhaust fan SCHEDULE IDENTIFIER PERFORMANCE ELECTRICAL specifications TENANT 48 2.017216 51ST AVENUE NE ARLINGTON, WA 98223 external INSTALL design SOUND POWER DIMENSIONS APPROX. TAG MAKE MODEL static MCA / MOPD NOTES LOCATION cfm (sones) SUPPLY (Ø X H) WEIGHT pressure ef-1,2,3,4 GREEN HECK GB-330-VG-50 ROOF 15000 .4 25 460/60/3 9/ 20 58.8 X 50.5 385 1,2 1. FAN opertaion TO BE CONTROLLED BY co/no SENSORS. 2. provide motorized damper. CEILING fan SCHEDULE IDENTIFIER PERFORMANCE ELECTRICAL specifications external INSTALL design SOUND POWER MOTOR SIZE DIMENSIONS APPROX. TAG MAKE MODEL static FLA (aMPS) INPUT POWER(w) STANDBY POWER NOTES LOCATION cfm (DBA) SUPPLY (W) (Ø IMPELLER) WEIGHT pressure Cf-1,2 GREEN HECK DS-3-24-70HV CEILING 89400 - 31 460/60/3 500 2.5 128 13 288 213 1 # INTAKE AIR HOOD SCHEDULE REVISIONS1. 01/15/2025 - EF-1,4 & CF-1,2 LOCATIONS CHANGED 2. 3. 4. 5. 6. 7. 8. IDENTIFIER PERFORMANCE DIMENSIONS SPECIFICATIONS INSTALL design static HOOD APPROX. TAG MAKE MODEL THROAT CURB CAP NOTES LOCATION cfm pressure (L X W X H) WEIGHT IAH- 1,2,3,4 GREEN HECK FGI ROOF 15000 .085 60 X 60 108 X 100 X29.5 66 X 66 394 1,2 11/04/20241/27/2025 1. PROVIDE GALVANIZED BIRDSCREEN-0.5 IN MESH TYPE. 2.provide motorized dampers. dampers to be interlocked with individual fans. K.S.B MECHANICAL PLANSSTART DATE:PRINT DATE:DRAWN BY: M0.0 SHEET G A N W EI , # MECHANICAL NOTES = E L O R 1. EXISTING EXHAUST FAN. SET FAN THERMOSTAT TO 90 DEG F. O N 2. CO/NO SENSORS TO BE INTERLOCKED WITH ROOF EXHAUST FANS. ISO O 3. 60" X 60 " INTAKE AIR HOOD ON ROOF. PROVIDE MOTORIZED DAMPER. C M 4. CF-1 AND CF-2 TO BE CONTROLLED BY SINGLE TOUCHSCREEN CONTROL. 5. Final loaction for installation to be verified on site. C& G 5 9'-9" E 54 EF-2 N (EXISTING) TO ROOF. I 1 AHU-1 (24K) X SERVER T 109 RA OB 1 T TO NEAREST . E CONDENSATE .O DRAIN. PH P NOT IN SCOPE S S 2 2 3 3 MD MD IAH-1 IAH-2 (ON ROOF) (ON ROOF) 2 4 S T 1 1 1 EF-1 EF-4 (ON ROOF) 1 (ON ROOF) MOUNTED ON EXISTING MD 5 MD I BEAM CF-1 42.0 288 3.0 5 CF-2 DETAIL B (TYP.) EXISTING I BEAM B B M1.0 M1.0 SCALE:1/8" - 1-0' 2 S S S 2 2 3 3 EXISTING. EF MD MD ROOF TENANT 48 2.017216 51ST AVENUE NE ARLINGTON, WA 98223 EF-2 (ON ROOF) IAH-3 IAH-4 MD MD (ON ROOF) (ON ROOF) 40 X 40 EF-3 A A (ON ROOF) M1.0 M1.0 SECURE DUCTWORK 50 X 25 2 TO WALL. S # 40 X 40 SCREENED OPENING. 24" ABOVE FFL. REVISIONS1. 01/15/2025 - EF-1,4 & CF-1,2 LOCATIONS CHANGED 2. 3. 4. 5. 6. 7. 8. DETAIL A (TYP.) 1st FLOOR MECHANICAL PLAN 11/04/20241/27/2025 SCALE:1/8" - 1-0' SCALE: 3/32" = 1-0' K.S.B N MECHANICAL PLANSSTART DATE:PRINT DATE:DRAWN BY: M1.0 SHEET G A N W EI , E # MECHANICAL NOTES = L O R O N 1. EXISTING EXHAUST FAN. SET FAN THERMOSTAT TO 90 DEG F. O O 2. CO/NO SENSORS TO BE INTERLOCKED WITH ROOF EXHAUST FANS. IS M 3. 60" X 60 " INTAKE AIR HOOD ON ROOF. PROVIDE MOTORIZED DAMPER. C 4. CF-1 AND CF-2 TO BE CONTROLLED BY SINGLE TOUCHSCREEN CONTROL. 5. Final loaction for installation to be verified on site. C& G 5 5 HP-1 EN 4 I 1 X 5 RT O A B . E .O PH P IAH-1 IAH-2 5 5 1 1 5 5 EF-1 EF-4 5 5 IAH-3 IAH-4 TENANT 48 2.017216 51ST AVENUE NE ARLINGTON, WA 98223 5 5 EF-2 EF-3 # REVISIONS1. 01/15/2025 - EF-1,4 & CF-1,2 LOCATIONS CHANGED 2. 3. 4. 5. 6. 7. 8. ROOF MECHANICAL PLAN 11/04/20241/27/2025 SCALE: 3/32" = 1-0' K.S.B N MECHANICAL PLANSSTART DATE:PRINT DATE:DRAWN BY: M2.0 SHEET CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 17216 51ST AVE NE STE 110 Permit #: 6263 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 31052100400100 DATE OF ISSUANCE. Scope of Work: Provide & install (4) exhaust fans, (4) intake air hoods, (2) ceiling Valuation: 150000.00 fans ,(1) heat pump and ductworks. OWNER APPLICANT CONTRACTOR SMARTCAP ARLINGTON AIRPORT PRECISE HEATING & COOLING LLC Precise Heating & Cooling, LLC INDUSTRIAL PA 8201 164TH AVE NE STE 110 PO BOX 1455 PO Box 1455 REDMOND, WA 98052 MONROE, WA, 98272 Monroe, WA 98272 425-319-3428 206-861-2525 LIC: 603 122 887 EXP: 06/30/2025 LIC: PRECIHC891L9 EXP: 06/29/2025 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC #: EXP: LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2021 STORIES: 1 CONST. TYPE: lllB DWELLING UNITS: 0 OCC GROUP: S-1; Storage Mod Hazard BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 01/30/2025 Applicant Signature Date Building Official Date CONDITIONS ADHERE TO THE APPROVED PLANS. APPROVED JOB COPY SHALL BE ONSITE FOR INSPECTIONS. CALL FOR INSPECTIONS. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 01/31/2025 Web Only - Mechanical Commercial Plan Review $1,246.86 01/31/2025 Credit Card Service $37.41 01/31/2025 Diffusers $15.00 01/31/2025 Ductwork/Dryer Duct $25.00 01/31/2025 Exhaust/Vents/Vent Fans $90.00 01/31/2025 Heat Pump - Condensing Unit $25.00 01/31/2025 Mechanical Misc. $60.00 01/31/2025 Processing/Technology $25.00 01/31/2025 Credit Card Service $7.20 Total Due: $1,531.47 Total Payment: $1,531.47 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail G A N W EI , # MECHANICAL NOTES = E L O R 1. EXISTING EXHAUST FAN. SET FAN THERMOSTAT TO 90 DEG F. O N 2. CO/NO SENSORS TO BE INTERLOCKED WITH ROOF EXHAUST FANS. ISO O 3. 60" X 60 " INTAKE AIR HOOD ON ROOF. PROVIDE MOTORIZED DAMPER. C M 4. CF-1 AND CF-2 TO BE CONTROLLED BY SINGLE TOUCHSCREEN CONTROL. 5. Final loaction for installation to be verified on site. C& G 5 9'-9" E 54 EF-2 N (EXISTING) TO ROOF. I 1 AHU-1 (24K) X SERVER T 109 RA OB 1 T TO NEAREST . E CONDENSATE .O DRAIN. PH P NOT IN SCOPE S S 2 2 3 3 MD MD IAH-1 IAH-2 (ON ROOF) (ON ROOF) 2 4 S T 1 1 1 EF-1 EF-4 (ON ROOF) 1 (ON ROOF) MOUNTED ON EXISTING MD 5 MD I BEAM CF-1 42.0 288 3.0 5 CF-2 DETAIL B (TYP.) EXISTING I BEAM B B M1.0 M1.0 SCALE:1/8" - 1-0' 2 S S S 2 2 3 3 EXISTING. EF MD MD ROOF TENANT 48 2.017216 51ST AVENUE NE ARLINGTON, WA 98223 EF-2 (ON ROOF) IAH-3 IAH-4 MD MD (ON ROOF) (ON ROOF) 40 X 40 EF-3 A A (ON ROOF) M1.0 M1.0 SECURE DUCTWORK 50 X 25 2 TO WALL. S # 40 X 40 SCREENED OPENING. 24" ABOVE FFL. REVISIONS1. 01/15/2025 - EF-1,4 & CF-1,2 LOCATIONS CHANGED 2. 3. 4. 5. 6. 7. 8. DETAIL A (TYP.) 1st FLOOR MECHANICAL PLAN 11/04/20241/27/2025 SCALE:1/8" - 1-0' SCALE: 3/32" = 1-0' K.S.B N MECHANICAL PLANSSTART DATE:PRINT DATE:DRAWN BY: M1.0 SHEET G A N W EI , E # MECHANICAL NOTES = L O R O N 1. EXISTING EXHAUST FAN. SET FAN THERMOSTAT TO 90 DEG F. O O 2. CO/NO SENSORS TO BE INTERLOCKED WITH ROOF EXHAUST FANS. IS M 3. 60" X 60 " INTAKE AIR HOOD ON ROOF. PROVIDE MOTORIZED DAMPER. C 4. CF-1 AND CF-2 TO BE CONTROLLED BY SINGLE TOUCHSCREEN CONTROL. 5. Final loaction for installation to be verified on site. C& G 5 5 HP-1 EN 4 I 1 X 5 RT O A B . E .O PH P IAH-1 IAH-2 5 5 1 1 5 5 EF-1 EF-4 5 5 IAH-3 IAH-4 TENANT 48 2.017216 51ST AVENUE NE ARLINGTON, WA 98223 5 5 EF-2 EF-3 # REVISIONS1. 01/15/2025 - EF-1,4 & CF-1,2 LOCATIONS CHANGED 2. 3. 4. 5. 6. 7. 8. ROOF MECHANICAL PLAN 11/04/20241/27/2025 SCALE: 3/32" = 1-0' K.S.B N MECHANICAL PLANSSTART DATE:PRINT DATE:DRAWN BY: M2.0 SHEET Permit #: 6263 Permit Date: 12/10/24 Permit Type: COMMERCIAL MECHANICAL Project Name: TENANT 48 2.0 Applicant Name: PRECISE HEATING & COOLING LLC Applicant Address: PO BOX 1455 Applicant, City, State, MONROE, WA, 98272 Zip: Contact: KANVIR BHOGAL Phone: 425-319-3428 Email: permits@precise-hvac.com Scope of Work: Provide & install (4) exhaust fans, (4) intake air hoods, (2) ceiling fans ,(1) heat pump and ductworks. Valuation: 150000.00 Square Feet: 35537 Number of Stories: 1 Construction Type: lllB Occupancy Group: S-1; Storage Mod Hazard ID Code: CIC Permit Issued: 01/31/2025 Permit Expires: 06/30/2025 Form Permit Type: COMMERCIAL MECHANICAL Status: COMPLETE Assigned To: Kristin Foster Property Parcel # Address Legal Description Owner Name Owner Phone Zoning SMARTCAP 17216 51ST AVE NE STE ARLINGTON 090 MASTER 31052100400100 110 AIRPORT ADDRESS INDUSTRIAL PA Contractors Contractor Primary Contact Phone Address Contractor Type License License # Precise Heating & CONSTRUCTION Jeffrey Heck 206-861-2525 PO Box 1455 COA 603 122 887 Cooling, LLC CONTRACTOR Precise Heating & CONSTRUCTION Jeffrey Heck 206-861-2525 PO Box 1455 L&I PRECIHC891L9 Cooling, LLC CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C14. Not 05/08/2025 MECHANICAL 05/09/2025 05/09/2025 BUILDING Completed FINAL Plan Reviews Date Review Type Description Assigned To Review Status COMMERCIAL 12/11/2024 BUILDING Approved MECHANICAL Fees Fee Description Notes Amount Enter 1 if permit is for commercial Web Only - Mechanical Commercial Plan mechanical $1,246.86 Review (Table 4-1) Credit Card Service $37.41 Diffusers Enter # of units $15.00 Ductwork/Dryer Duct $25.00 Exhaust/Vents/Vent Fans $90.00 Heat Pump - Condensing Unit Enter # of units $25.00 Mechanical Misc. Not otherwise specified $60.00 Processing/Technology $25.00 Credit Card Service $7.20 Total $1,531.47 Attached Letters Date Letter Description 01/30/2025 Building Permit 12/11/2024 Building Permit 12/10/2024 Web Form - Building Application Payments Date Paid By Description Payment Type Accepted By Amount XBP Conf: 12/10/2024 $1,246.86 217268579 12/10/2024 Kanir Bhogal 217268579 Hannah Hardwick $37.41 XBP Conf: 01/23/2025 $240.00 221149543 01/23/2025 Kanvir Bhogal 221149543 $7.20 Outstanding Balance $0.00 Notes Date Note Created By: 01/27/2025 Emailed requesting that the revisions be clouded. Kristin Foster 01/21/2025 Received revised plans. Kristin Foster Uploaded Files Date File Name 01/31/2025 24064763-20250131_BLD6263_ApprovedPlans.pdf 01/31/2025 24060610-20250130_BLD6263_IssuedPermit.pdf 01/27/2025 23983985-20250121_BLD6263_Plans.pdf 01/27/2025 23983986-20250121_BLD6263_Structural.pdf 01/27/2025 23983987-20250121_BLD6263.pdf 12/11/2024 23466130-20241210_BLD6263_Application.pdf 12/11/2024 23466131-20241210_BLD6263_PlansandSpecs.pdf