Loading...
HomeMy WebLinkAbout7220 201st St Ne_BLD346_2025 COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 Phone (360) 403-3551 THIS APPLICATION TO BE USED FOR NEW COMMERCIAL STRUCTURES AND RESIDENTIAL DWELLINGS NOT REGULATED UNDER THE IRC. PLEASE FOLLOW THE SUBMITTAL REQUIREMENTS CHECKLIST TO MAKE SURE THAT ALL THE REQUIRED DOCUMENTS ARE SUBMITTED FOR REVIEW. Name of Project: Microgreen Polymers, Inc Project Address: 7220 201st NE Parcel ID# 007933000023 00 Project Valuation: 790000 Legal Description: Lots 23/24 in Jensen Business Park Owner: Jensen Business Parks, LLC Address: 20613 Old Burn Hill Road City: Arlington State: WA ZIP: 98223 Contact Person: Trevor Gaskin Phone: 425-923-0277 Cell Phone: Same E-mail: trevor@coastccg.com Address: 328 N. Olympic Ave. City: Arlington State: WA ZIP: 98223 Engineer: B&T Design and Engineering Phone: 425-557-0779 Cell Phone: Same E-mail: jim@bntengr.com Address: 250 E. Sunset Way City: Issaquah State: WA ZIP: 98027 License Number: 23915 Expiration: 0 General Contractor: Coast Construction Group Phone: 360-474-0600 Cell Phone: N/A Address: 328 N. Olympic Ave. E-mail: trevor@coastccg.com City: Arlington State: Was hing ton ZIP: 98223 License Number: COASTCG865CG Expiration: 0 Proposed Scope of Work Building Addition of 4948 SF; 1418 SF of Tenant Improvement and Occupancy: Project Name/Tenant: Microgreen Polymers, Inc. Site Address: 7220 201st NE Bldg/Suite/Unit IBC Construction Type: F1/B IBC Occupancy Type: F1/B Description of Use: Manufacturing/Commercial Building Square Footage: 32624 Number of Stories: 2 Square Footage Per Floor: 1st Floor - 30139, 2nd Floor - 2485 Will there be any installation, modification or removal of the following? (Check all that apply) Automatic fire extinguishing systems Compressed gas systems Fire alarm and detection systems Fire pumps Flammable and combustible liquids (tanks, piping etc…) Hazardous materials High piled/rack storage Industrial ovens/furnace Private fire hydrants Spraying or dipping operations Standpipe systems Temporary membrane structure, tents (>200sq ft) or canopies (>400 sq ft) Provide details on any of the above checked items: N/A Installation, changes, modifications or removal of any of the above may require additional submittals,information, or permits during the plan review or construction process. Statement of Special Inspection Name of Project: N/A Project Address: N/A Special Inspection Firm: N/A Address: N/A Contact Person: N/A Phone: N/A Special Inspection Firm Special Inspectors: The Special Inspection Firm Listed above will perform special inspection for the following types of work (separate forms must be submitted if more than one firm is to be employed). Reinforced Concrete Bolting in Concrete Pre-stressed Concrete Shotcrete Structural Masonry Structural Steel and Welding High-Strength Bolting Spray-Applied Fireproofing Smoke-Control Systems Other All individual inspectors to be employed on this project will be WABO certified for the type of inspection they are to perform. If inspection is for work that is not covered by the WABO categories, a detailed resume of the inspector and firm must be submitted. The resume must show the inspector and firm are qualified to perform the work and testing required by the project design and specifications. The work shall be inspected for conformance with the plans and specifications approved by the City. Revisions and addenda sheets will not be used for inspection unless approved by the City. The special inspector shall report to the City revisions that are not approved. A daily record will be maintained on site itemizing the inspections performed, for the review of all parties. Any nonconforming items shall be brought to the immediate attention of the contractor for resolution. A weekly shall be submitted to the City; detailing the inspections and testing performed, listing any nonconforming items and resolution of nonconforming items. Unresolved nonconforming items will be detailed on a discrepancy report and presented to the building department. A final report shall be submitted to the Building Division prior to the Certificate of Occupancy being issued. This report will indicate that inspection and testing was completed in conformance with the approved plans, specifications and approved revisions and addenda. Any unresolved discrepancies must be detailed in the final report. The special inspector and special inspection firm serve in the role as “deputy” City of Arlington inspectors and as such are responsible to the City of Arlington Building Division in the performance of the required work. Contractor: The contractor shall provide the special inspector or agency adequate notification of work requiring inspection. The City approved plans and specifications must be made available, at the job site for the use of the special inspector and the City Inspector. The contractor shall maintain all daily inspections reports, on site, for review. The special inspection functions are considered to be in addition to the normal inspections performed by the City and the contractor is responsible for contacting the City to schedule regular inspections. No concrete shall be poured or other work covered until approved by the City Inspector. Building Division: The Building Division shall review any revisions and addenda. Approved copies will be given to the contractor to maintain as part of the approved plan set. The City Inspector will monitor the special inspection functions for compliance with the agreement and the approved plans. The City Inspector shall be responsible for approving various stages of construction to be covered and work to proceed. Design Professionals: The architect and engineer will clearly indicate on the plans and specifications for the specific types of special inspection required, and shall include a schedule for inspection and testing. The architect and engineer will coordinate their revisions and addenda process in such a way as to insure all required City approvals are obtained, prior to work shown on the revisions being performed. Owner: The project owner, or the architect or engineer acting as the owners agent, shall employ the special inspector or agency. ENFORCEMENT: A failure of the special inspector or firm to perform in keeping the requirements of the IBC, the approved plans and this document may void this agreement and the Building Officials approval of the special inspector. In such case a new special inspector and/or firm would need to be proposed for approval. A failure of the design and/or construction parties to perform in accordance with this agreement may result in a STOP WORK notice being posted on the project, until nonconforming items have been resolved. ACKNOWLEDGEMENTS: The building permit does not include any mechanical, electrical, plumbing or fire sprinkler/alarm work. These permits are issued separately. Mechanical, electrical, plumbing, or fire sprinkler/ alarm permits require a separate permit application and may also require separate plan review. Please note that any tenant improvement work in a space that involves food handling or preparation requires Snohomish County Health District approval before the permit can be issued. You must provide the Permit Center a copy of the approval letter or the approved plans. Contact the Snohomish County Health District at (425) 339-5250 with any questions or for more information. An intake appointment is required for all large Tenant Improvement Building Permit Applications. To determine if your project requires an intake appointment, to schedule an appointment or to ensure that you have the most current information, please contact the City of Arlington Permit Center at (360) 403-3551 or by email to permitcenter@arlingtonwa.gov. I have read and agree to comply with the terms and conditions of this agreement. Please Attach Plans and Supporting Documents (PDF Only) Coast_Microgreen.pdf STAFF USE ONLY: Permit Number: Accepted Receipt # By: Date Received: Amount Received: By submission of this form, I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington. SITE PLAN INFORMATION PROJECT INFORMATION 348.25' 201ST STREET NE S87° 59' 12"E MICROGREEN Coast Construction Group " 0 '- 328 N Olympic Ave 0 PROJECT INFO 4 Arlington, WA 98223 27'-0" TAX ACCOUNT NUMBER: 00793300002300 / 00793300002400 p. 360-474-0600 WATER SERVICE: CITY OF ARLINGTON POLYMERS f. 360-474-1095 SEWER SERVICE: CITY OF ARLINGTON www.CoastCCG.com FIRE DISTRICT: CITY OF ARLINGTON PROJECT AREA: 2.5 ACRES 7220 201ST STREET NE SITE ADDRESS: 7220 201ST STREET NE, ARLINGTON, WA ZONING / COMP. PLAN: G.I. - GENERAL INDUSTRIAL ARLINGTON, WA 98223 PROPOSED LAND USE: G.I. - GENERAL INDUSTRIAL DATUM (VERT / HORIZ): NAVD 88 / NAD 83 ADA PROJECT LOCATION MAP DEVELOPER EXISTING BUILDING AREA COAST CONSTRUCTION GROUP TREVOR GASKIN 201ST STREET NE MICROGREEN POLYMERS E 328 OLYMPIC AVE " 59 ARLINGTON, WA 98223 '.5 ' 9 0 (425) 923-0277 2 °3 W 0 "9 N '. 5 5 ' 9 0 2 3 ° 0 PROPOSED NEW AREA S CONTACT / ENGINEER HALE MILLIGAN & ASSOCIATED LLC POLYMERS KELLI HALE, PE MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 307 OLYMPIC AVE, SUITE 209 ARLINGTON, WA 98223 (360) 474-4624 LEGAL DESCRIPTION SECTION 14 TOWNSHIP 31 RANGE 05 QUARTER NW PROJECT INFORMATION JENSEN BUSINESS PARK, PHASE 2 BLK 000 D-00 LOT 23 JENSEN BUSINESS PARK, PHASE 2 BLK 000 D-00 LOT 24 MICROGREEN POLYMERS SCALE: 1 IN = 30 FT 7220 201ST STREET NE ARLINGTON, WA 98223 348.25' N87° 59' 12"W SNOHOMISH COUNTY PARCEL# GENERAL NOTES CODE INFORMATION PROJECT CONTACTS SHEET INDEX 00793300002300 00793300002400 DESIGNER T-1 TITLE SHEET PROJECT NO.: ALL CONSTRUCTION FOR THIS PROJECT 1. CONTRACTOR SHALL VERIFY AND COORDINATE ALL DRAWINGS AND REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR SHALL COMPLY WITH THE FOLLOWING: COAST CONSTRUCTION GROUP X ____________ CLARIFICATION AND RESOLUTION PRIOR TO PERFORMING ANY WORK. DISCREPANCIES AMONG THE DRAWINGS OR BETWEEN THE 328 N OLYMPIC AVE PROPOSED CONSTRUCTION PAGES DRAWINGS AND THE SITE CONDITIONS DO NOT QUALIFY AS GROUNDS FOR COMPENSATION FROM THE OWNER, PROFESSIONALS FOR 2012 INTERNATIONAL BUILDING CODE ARLINGTON, WA 98223 DRAWN BY: ERRORS IN BUILD-OUT OR INSTALLATION. 2012 INTERNATIONAL MECHANICAL CODE O 360-474-0600 DS 2012 INTERNATIONAL FIRE CODE F 360-474-1095 A-1 BUILDING ELEVATIONS ____________ 2012 INTERNATIONAL FUEL GAS CODE 2. DO NOT SCALE THE DRAWING. 2012 UNIFORM PLUMBING CODE CONTACT: TREVOR GASKIN A-2 LOWER FLOOR PLAN CHECKED BY: NATIONAL ELECTRICAL CODE (NFPA 70) EMAIL: TREVOR@COASTCCG.COM A-3 UPPER FLOOR PLAN 3. ALL WORK SHALL CONFORM TO THE LATEST ADOPTED ISSUES OF ALL APPLICABLE CODES AND LOCAL REGULATIONS. 2009 ICC/ANSI A117.1-09 ____________TG 2012 WASHINGTON STATE ENERGY CODE A-4 DOORS AND WINDOWS CONTRACTOR 4. ALL NEW WORK SHALL BE IN COMPLIANCE WITH FEDERAL, STATE, AND LOCAL REGULATIONS. COAST CONSTRUCTION GROUP A-5 LIGHTING AND CEILING 328 N OLYMPIC AVE A-6 HVAC AND VENTILATION REVISIONS: OCCUPANCY TYPE - F1 / B 5. ALL DIMENSIONS ARE INSIDE ROOM CLEAR DIMENSIONS, UNLESS NOTED OTHERWISE. CONSTRUCTION TYPE - VB ARLINGTON, WA 98223 A-7 PLUMBING AND FIXTURES 4/10/2014 SPRINKLERED - YES O 360-474-0600 FIRE ALARMED - YES A-8 FLOOR AND ROOF FRAMING 6. CONTRACTOR SHALL PROVIDE ALL NEEDED BLOCKING FOR ATTACHMENT OF WALL-HUNG ITEMS. F 360-474-1095 CONTACT: TREVOR GASKIN B-1 BUILDING SECTIONS 7. CONTRACTOR SHALL PROVIDE SEISMIC BRACING FOR CEILING SYSTEM & OTHER SUSPENDED FIXTURES AS NECESSARY. SQUARE FOOTAGE SUMMARY EMAIL: TREVOR@COASTCCG.COM B-2 LOADING RAMP AND STORM WATER C-1 GENERAL NOTES / ENERGY CODE 8. CONTRACTOR SHALL PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY THE FIRE DEPARTMENT. EXISTING MANUFACTURING AREA 27,500 ENGINEER EXISTING MAIN FLOOR OFFICE AREA 2,639 C-2 ACCESSIBLE NOTES AND DETAILS B&T DESIGN AND ENGINEERING EXISTING UPPER FLOOR OFFICE AREA 2,485 9. EXTERIOR SIGNAGE TO BE PROVIDED BY THE OWNER UNDER SEPARATE CONTRACT. P.O. BOX 595 TOTAL EXISTING FLOOR AREA 32,624 NEW SHIPPING AREA 4,948 ISSAQUAH, WA 98027 EXISTING BUILDING AND DEMO PAGES 10. CONTRACTOR SHALL COORDINATE WITH OWNER AND RECONCILE WITH PLANS TO DETERMINE SCOPE OF DEMO WORK. NEW MAIN FLOOR OFFICE AREA 709 O 425-557-0779 NEW UPPER OFFICE AREA 709 F 425-557-0765 TOTAL NEW FLOOR AREA 6,366 CONTACT: JIM TRUEBLOOD E-1 EXISITNG BUILDING ELEVATIONS ISSUED: TOTAL FLOOR AREA AFTER ADDITION 38,990 EMAIL: JIM@BNTENGR.COM E-2 EXISTING LOWER FLOOR E-3 EXISTING UPPER FLOOR OCCUPANCY LOAD TENANT MICROGREEN POLYMERS PER IBC TABLE 1004.1.2 STRUCTURAL AND ENGINEERING 7220 201ST STREET NE BUSINESS FACTOR = 100 ARLINGTON, WA 98223 INDUSTRIAL FACTOR = 100 TYPE F1 INDUSTRIAL AREA 32,448 / 100 = 324 O 360-435-7400 S1.1 FOUNDATION PLAN TYPE B BUSINESS AREA 6,542 / 100 = 65 F 360-435-0248 S1.2 SECOND FLOOR FRAMING PLAN CONTACT: TONY LASALATA S1.3 ROOF FRAMING PLAN EMAIL: TONY.LASALATA@MICROGREENINC.COM S2.1 STANDARD DETAILS AND NOTES OWNER S2.2 STANDARD DETAILS JENSEN BUSINESS PARK, LLC SHEET NUMBER / TITLE S3.1 FOUNDATION DETAILS 20613 OLD BURN HILL RD S4.1 FLOOR FRAMING DETAILS ARLINGTON, WA 98223 O 425-356-7082 S5.1 ROOF FRAMING DETAILS F 360-652-5161 T-1 CONTACT: DEAN JENSEN EMAIL: DAJEX54@MSN.CO Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com NEW TPO ROOF WITH SCUPPERS AND DOWNSPOUTS STANDING SEAM METAL ROOFING TO MATCH EXISTING WITH GUTTERS AND DOWNSPOUTS BUILDING OVERVIEW POLYMERS NTS MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 LOADING DOCK RAMP TO BE 48" LOWER THAN FINISHED FLOOR PROJECT INFORMATION MICROGREEN POLYMERS 7220 201ST STREET NE ARLINGTON, WA 98223 UPPER FLOOR CEILING HT CMU WALL HT SNOHOMISH COUNTY PARCEL# 00793300002300 00793300002400 20'-1" 19'-0" PROJECT NO.: X ____________ DRAWN BY: DS WEST ELEVATION ____________ SCALE: 1 IN = 10 FT CHECKED BY: TG ____________ REVISIONS: 4/10/2014 ISSUED: SOUTH ELEVATION SCALE: 1 IN = 10 FT SHEET NUMBER / TITLE NORTH ELEVATION EAST ELEVATION A-1 SCALE: 1 IN = 20 FT SCALE: 1 IN = 20 FT ELEVATIONS 25'-0" 250'-0" 24'-11" Coast Construction Group 3070 5040FX 328 N Olympic Ave A A Arlington, WA 98223 5'-8 1/2" 18'-0" EXISTING ROLLUP 5'-0" p. 360-474-0600 7'-6" f. 360-474-1095 3068 www.CoastCCG.com 6'-0" 6040FX 15'-6" 6" 7'-3" 6'-0" 3068 6040FX A 3068 36'-7" 4'-0" 49'-0" 6'-0" 6040FX 6" EXISTING - NO WORK IN THIS AREA 6'-0" 6040FX 3'-6" 5068 UP 5'-0" H REPLACE SINK AND EXISTING COUNTER 6'-0" 5040FX WALL LEGEND 6040FX 11'-4" A EXISTING 6" CONCRETE TILT UP TYPE WALL 2'-8" 3068 3068 2'-2" B 8" CMU BLOCK WALL POLYMERS 12'-0" 3068 C 7220 201ST STREET NE ARLINGTON, WA 98223 4040FX 2X6 AT 16" OC WOOD FRAMED EXTERIOR WALL WITH 5/8 GWB INT AND STUCCO EXT MICROGREEN 9'-6 1/2" D 2X6 AT 16" OC WOOD FRAMED INTERIOR WALL WITH 5/8 GWB BOTH SIDES 14'-0" 3070 4'-6 1/2" 14'-9" 4040FX 110'-0" 7'-2" 5'-1 1/2" 9'-4" E 2X4 AT 16" OC WOOD FRAMED INTERIOR WALL WITH 5/8 GWB BOTH SIDES EXISTING ROLLUP 4040FX UP 3068 4'-2" F 2X3 AT 16" OC WOOD FRAMED INTERIOR WALL WITH 5/8 GWB ONE SIDE 3068 5068 1'-9" G NEW WALL TO BE FRAMED IN EXISTING AREA 42'-0" 4'-9" H NEW OPENING / DOOR IN EXISTING WALL 7'-6 1/2" 6'-0" 6040FX 8040FX 3068 H 3068 D PROJECT INFORMATION 19'-3" MEN 3068 4'-9" G G MICROGREEN 9'-9" 3068 ADA POLYMERS 6'-0" 3068 6040FX 10'-3" G D G D 7220 201ST STREET NE 2'-4" 3068 4'-9" G 26'-8" ARLINGTON, WA 98223 ADA G 47'-0" 9'-8 1/2" 3068 G 5'-2" 14'-4" 16'-3" SNOHOMISH COUNTY 6'-0" 6040FX 11'-4 1/2" WOMEN 3068 G 38'-8" 10'-3" 3'-10" TOP OF EXISITING FINISHED FLOOR ELEVATION = 120 FT PARCEL# 3'-5" 11'-1 1/2" E 00793300002300 G 9'-0" 3068 3068 00793300002400 3'-8 1/2" G 6'-11 1/2" 6'-0" 9'-0" 15'-3" G G 7'-9 1/2" 6040FX 3068 SHIPPING G TEAM 9'-6" PROJECT NO.: 13'-0" ROOM G G OFFICE X 11'-0" 11'-3" 9'-2" ADA NEW 12 X 12 ROLLUP ____________ 7'-0" EXISTING ROLLUP H H 100'-6" EXISTING AREA F 10'-9 1/2" F 12 W X 12 H H 12 W X 12 H EXISTING AREA 3068 A 3068 5070 3070 A 3070 3070 A A DRAWN BY: NEW AREA F F F NEW AREA 74'-9" 75'-0" 4'-3" 3068 4'-6" 4'-6 1/2" 4'-6" 11'-5" 12'-0" 11'-0" 12'-0" 50'-0" DS KEEP WINDOW ____________ CLOSE OFF 3068 D D WINDOW 6'-0" 6040FX 41'-9 1/2" CHECKED BY: 14'-4 1/2" 15'-11" 9 W X 12 H 5040FX 9'-4 1/2" OFFICE ____________TG F 14'-0" 4'-6" E 5068 3068 E EXISTING AREA 8'-9" 4040FX NEW 9 X 12 ROLLUP 24'-10 13/16" 30'-0" C B 30'-0" 30'-0" D REVISIONS: TOP OF FINISHED FLOOR ELEVATION = 120 FT A5 10 ROLLUP 10 ROLLUP 10 ROLLUP10 H B 10 H 10 H 4/10/2014 D X 9 X X 9 X X 9 X W 12'-0" W W 6'-0" 5068 9 9 9 NEW AREA 6040FX 14'-8" 30'-0" EXISTING AREA 14'-10 1/2" TOP OF TRUCKK LOADING RAMPCANTILEVER TRUSSES AT THIS BEAM LINE 12'-0" 10'-0" F AT WALL ELEVATION TO BE 116 FT 5'-0" EXISTING AREA 10'-0" EXISTING ROLLUP B 5'-7 3/16" C 12'-0" ROOF BEAM 5040FX 3640FX 3070 6040FX 3070 3070 NEW AREA 2'-5" 9" 3'-0" 5'-0" 9'-0" 3'-6" 3'-0" 15'-0 1/2" 3'-0" 12'-0" NOTE: SEE DETAILS FOR OIL EXISTING COLUMN WATER SEPARATOR VAULT B TOP OF FINISHED FLOOR ELEVATION = 120 FT 25'-0" 66'-3 3/16" 62'-4 1/8" 15'-0" 60'-0" A 36'-0" B A5 E A5 B A5 12'-0" (1) EXISTING LOADIN RAMP (2) NEW LOADING RAMPS ROOF BEAM 30'-0" ISSUED: 15'-0" 12 X 14 ROLLUP B 12 W X 14 H 2'-0" 8'-2 11/16" 12'-0" 22'-2 11/16" F 16'-0" PROPOSED LOWER FLOOR A5 C SCALE: 1 IN = 10 FT A6 SHEET NUMBER / TITLE A-2 PROPOSED LOWER FLOOR 25'-0" 250'-0" Coast Construction Group 5040FX 5040FX 328 N Olympic Ave A A Arlington, WA 98223 5'-0" p. 360-474-0600 f. 360-474-1095 11'-0" www.CoastCCG.com 6'-0" 6040FX 3068 6" 9'-10 1/2" 14'-4 1/2" 6'-0" 6040FX NEW DESK A 10'-0 1/2" 3068 AND COUNTER 4'-0" 16'-4" 3068 D1 DN 6'-0" 6040FX 6040FX WALL LEGEND 9'-0" 6" 3'-7 1/2" A EXISTING 6" CONCRETE TILT UP TYPE WALL 3068 6'-0" 6040FX B 8" CMU BLOCK WALL 10'-0" G 3068 C 2X6 AT 16" OC WOOD FRAMED EXTERIOR WALL WITH 5/8 GWB INT AND STUCCO EXT 5'-0" G D 2X6 AT 16" OC WOOD FRAMED INTERIOR WALL WITH 5/8 GWB BOTH SIDES 10'-2" 17'-8 1/2" E 2X4 AT 16" OC WOOD FRAMED INTERIOR WALL WITH 5/8 GWB BOTH SIDES 6'-0" 6040FX 10'-9" F 2X3 AT 16" OC WOOD FRAMED INTERIOR WALL WITH 5/8 GWB ONE SIDE 3068 DN G NEW WALL TO BE FRAMED IN EXISTING AREA POLYMERS H NEW OPENING / DOOR IN EXISTING WALL 3068 MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 9'-6" 4'-0" 110'-0" 14'-0" OPEN TO BELOW 3068 3068 6'-6" 6'-0" 6040FX 10'-4" EXISTING RAILING PROJECT INFORMATION 6'-6" 4'-9" 3068 3068 MICROGREEN 10'-0" POLYMERS 6'-0" 10'-4" 3068 6040FX UP 11'-5" 7220 201ST STREET NE 4'-9" 5 STEPS UP TO ARLINGTON, WA 98223 3068 EXISTING STORAGE MEZZANINE 6'-0" SNOHOMISH COUNTY 6040FX 11'-10" 3068 EGRESS 4'-2" PARCEL# 00793300002300 3'-5" G REPLACE EXISTING 00793300002400 SINK AND CABINET 3068 5068 EXISTING STAIRS 48" WIDE 6'-0" 6040FX G 11'-0 1/2" 4'-0" 10'-5 1/2" EGRESS ROUTE PROJECT NO.: 12'-10" G G G X 7'-0" ____________ 9'-6" 3068STORAGE 5'-0" EXISTING AREA A H A DRAWN BY: NEW AREA F F 4'-3" 3068 3068 DS ____________ 6'-0" 13'-3" CHECKED BY: 6040FX 9'-6" 4'-0" 10'-5 1/2" ____________TG 4'-3" E 3068 5'-0" B REVISIONS: 5040FX C 4/10/2014 4'-0" 16'-0" F 5'-0" 5040FX 1'-6" C 5040FX 5040FX 3'-0" 5'-0" 9'-0" 5'-0" 3'-8" PROPOSED UPPER FLOOR SCALE: 1 IN = 10 FT ISSUED: SHEET NUMBER / TITLE A-3 PROPOSED UPPER FLOOR Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 100 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com 100 DN 300 B 100 UP 100 DN 100 100 100 100 POLYMERS 60 MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 100 UP 100 100 100 100 40 100 100 100 100 100 PROJECT INFORMATION 300 300 B MICROGREEN B POLYMERS 100 300 B 7220 201ST STREET NE 100 300 ARLINGTON, WA 98223 B SNOHOMISH COUNTY 100 300 PARCEL# 100 00793300002300 00793300002400 100 300 A EXISTING AREA PROJECT NO.: 500 500 B A NEW AREA X EXISTING AREA EXISTING 300 300 ____________ B B NEW AREA 200 600 600 A 100 100 100 10 DRAWN BY: 800 DS 10 300 ____________ B 60 CHECKED BY: 300 70 B TG ____________ 50 300 B 700 700 700 REVISIONS: 10 70 4/10/2014 70 70 20 30 10 400 400 400 C C C LOWER FLOOR UPPER FLOOR ISSUED: 900 SHEET NUMBER / TITLE A-4 DOORS AND WINDOWS Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com DN UP DN POLYMERS MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 UP PROJECT INFORMATION MICROGREEN POLYMERS 3 BULB RECESSED TROFFER FIXTURE 7220 201ST STREET NE 2 BULB TS FIXTURE ARLINGTON, WA 98223 6 BULB T5 FIXTURE EXTERIOR 54 WATT LED SNOHOMISH COUNTY WALL PACKS PARCEL# EXISTING LIGHTING TO 00793300002300 REMAIN IN THIS ROOM 00793300002400 PROJECT NO.: X ____________ EXISTING AREA DRAWN BY: NEW AREA DS ____________ CHECKED BY: TG ____________ EXISTING AREA / NO WORK IN THIS AREA REVISIONS: 4/10/2014 LOWER FLOOR UPPER FLOOR ISSUED: LIGHTING AND CEILING SCALE: 1 IN = 10 FT SHEET NUMBER / TITLE A-5 LIGHTING AND ELECTRIC Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com DN UP DN POLYMERS MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 UP PROJECT INFORMATION MICROGREEN POLYMERS 7220 201ST STREET NE ARLINGTON, WA 98223 SNOHOMISH COUNTY PARCEL# 00793300002300 00793300002400 PROJECT NO.: X ____________ DRAWN BY: R R R DS ____________ W R CHECKED BY: R W W W ____________TG EXISTING AREA / NO WORK IN THIS AREA REVISIONS: THERMOSTAT R THERMOSTAT W 4/10/2014 W R W W W OUTDOOR UNITS LOCATED LOWER FLOOR UPPER FLOOR ALONG THIS WALL W WARM AIR DIFFUSER EQUIPMENT (LOWER FLOOR): W WARM AIR DIFFUSER AMERICAN STANDARD 2-1/2 TON HEAT PUMP SYSTEM AIR HANDLER: TAM7A0B30H21, WITH 10 KW STRIP HEAT R RETURN AIR DIFFUSER HEAT PUMP: 4A6H3030 R RETURN AIR DIFFUSER ISSUED: EQUIPMENT (UPPER FLOOR): AMERICAN STANDARD 2 TON HEAT PUMP SYSTEM AIR HANDLER: TAM7A0B30H21, WITH 10 KW STRIP HEAT HEAT PUMP: 4A6H3024 HVAC AND VENTILATION SCALE: 1 IN = 10 FT SHEET NUMBER / TITLE A-6 HVAC AND VENTILATION Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com DN UP PLUMBING FIXTURES C A EXISTING / NO CHANGE DN B NEW SINK AND FAUCET POLYMERS MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 C REPLACE EXISTING SINK AND FAUCET UP D NEW WALL HUNG LAV, WATER CLOSET, URINAL, AND FLOOR DRAIN. ALL TO BE ADA COMPLIANT. A PROJECT INFORMATION A A MICROGREEN POLYMERS 7220 201ST STREET NE NOTE: ARLINGTON, WA 98223 3" DRAIN A RELOCATE EXISTING SERVICE LINES AS REQUIRED SNOHOMISH COUNTY C PARCEL# 00793300002300 CUT CONCRETE AND TIE INTO EXISTING WASTE LINE 00793300002400 H / W C / W C / W H / W 2" DRAIN PROJECT NO.: C / W C / W C / W H / W C / W C / W 2" DRAIN C / W H / W X C / W 2" DRAIN ____________ H / W H / W H / W H / W C / W H / W DRAWN BY: D DS ____________ C / W H / W CHECKED BY: TG C / W H / W ____________ EXISTING AREA / NO WORK IN THIS AREA B C / W H / W REVISIONS: C / W C / W 4/10/2014 H / W H / W H / W LOWER FLOOR UPPER FLOOR ISSUED: PLUMBING AND FIXTURES SCALE: 1 IN = 10 FT SHEET NUMBER / TITLE A-7 PLUMBING AND FIXTURES Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com 100'-6" E S3.1 EXISTING AREA NEW AREA SINGLE JOIST AT THIS SPAN 5'-2" CEILING FRAMING TO BE (2) 2X12 HF#2 AT 16" OC WITH 5/4 T&G SHEATING EXISTING AREA / NO WORK IN THIS AREA 30'-0" 4X12 DF#2 HEADER 4X12 DF#2 AT DOOR, WINDOW, 24'-2" AND HALLWAY 12'-0" 5'-7 3/16" E S3.1 19'-11" 22'-6 1/2" POLYMERS MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 25'-0" 66'-3 3/16" 50'-4 1/8" FLOOR AND STORAGE 30'-0" CEILING FRAMING SCALE: 1 IN = 10 FT PROJECT INFORMATION MICROGREEN POLYMERS 22'-2 11/16" 7220 201ST STREET NE ARLINGTON, WA 98223 SNOHOMISH COUNTY PARCEL# 00793300002300 00793300002400 PROJECT NO.: X ____________ DRAWN BY: DS ____________ 100'-6" CHECKED BY: EXISTING AREA NEW AREA TG ____________ REVISIONS: MANUFACTURED TRUSSES AT 24" OC 4/10/2014 WITH 3:12 ROOF PITCH EXISTING AREA / NO WORK IN THIS AREA 30'-0" 12'-0" CANTILEVER ROOF TRUSSES AT THIS LOCATION MANUFACTURED TRUSSES AT 24" OC WITH 4:12 ROOF PITCH 5'-7 3/16" 2X12 HF#2 RAFTERS AT 24" OC ISSUED: 25'-0" 66'-3 3/16" 50'-4 1/8" 30'-0" ROOF FRAMING SCALE: 1 IN = 10 FT 22'-2 11/16" FOR ADDITIONAL FRAMING AND SHEET NUMBER / TITLE STRUCTURAL INFORMATION REFER TO STRUCTURAL (S) PAGES A-8 FLOOR AND ROOF FRAMING PLAN Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com 3:12 ROOF PITCH PROVIDE 8 INCH GAP 8" TO WALL FOR EXISTING MANUFACTURED TRUSSES AT 24" OC (HIP ROOF) 12 INCH HEEL HEIGHT CONDUIT AT WALL AT TRUSS BEARING MAUNFACTURED HIPSET TRUSSES 5/8 GWB AT CEILING 25'-0" SOFFIT INTEGRATED INTO TRUSS DESIGN EXISTING 6" 33'-0" 48" CONCRETE TILT UP TYPE WALL 114 3/4" 30'-0" 114 3/4" 241" NEW CMU WALL 241" 2X6 AT 16" OC WOOD FRAMED WALL 36" 5/4" T&G FLOOR SHEATHING 5/4 T&G FLOOR SHEATHING CMU WALL MAUNUFACTURED FLOOR 22" 22" DEEP FLOOR TRUSSES AT 24" OC 22" TRUSSES AT 24" OC 19'-0" 2X6 AT 16" OC WOOD FRAMED WALL POLYMERS 5/8 GWB AT CEILING MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 EXISTING 6 INCH TILT UP WALL 48" 123 1/2" 123 1/2" 103" 103" NEW AREA EXISTING AREA 36" OUTSIDE WALL HEIGHT FOR 1 1/2" TOP CHORD BEARING FLOOR TRUSSES TOP OF 6" SLAB FLOOR ELEVATION = 120 TOP OF 6" CONCRETE SLAB FLOOR ELEVATION = 120 TOP OF 6" CONCRETE SLAB FLOOR ELEVAION = 120 8" PROJECT INFORMATION EXISTING FOOTING AND SLAB FLOOR CONCRETE FOOTING AND 8 INCH STEM WALL TO EXTEND 8 INCHES ABOVE SLAB MICROGREEN SECTION D POLYMERS SECTION A SECTION B SCALE: 1/4 IN = 1 FT SCALE: 1/4 IN = 1 FT SCALE: 1/4 IN = 1 FT 7220 201ST STREET NE ARLINGTON, WA 98223 SNOHOMISH COUNTY PARCEL# 00793300002300 00793300002400 PROJECT NO.: X ____________ DRAWN BY: DS ____________ CHECKED BY: TG ____________ 3:12 ROOF PITCH PROVIDE 8 INCH GAP REVISIONS: 8" TO WALL FOR EXISTING 12 INCH HEEL HEIGHT CONDUIT AT WALL 4/10/2014 AT TRUSS BEARING 2X12 HF#2 RAFTERS AT 24" OC WITH 1/4 IN TO 1 FT SLOPE SOFFIT INTEGRATED 6 3/4 X 24 24F GLB INTO TRUSS DESIGN EXISTING ROOF 33'-0" SUPPORT BEAM 15'-0" 15'-0" 30'-0" ISSUED: STORAGE DECK ABOVE OFFICES (LL=125) (2) 2X12 HF#2 AT 16" OC NEW CMU WALL 19'-0" 19'-0" EXISTING COLUMN 14'-8" 14'-8" EXISTING 6 INCH TILT UP WALL 10'-0" CMU WALL TOP OF 6" CONCRETE SLAB FLOOR ELEVATION = 120 8" SHEET NUMBER / TITLE CONCRETE FOOTING AND 8 INCH STEM WALL TO EXTEND 8 INCHES ABOVE SLAB SECTION F SECTION E SCALE 1/4 IN = 1 FT FOR ADDITIONAL FRAMING AND SCALE: 1/4 IN = 1 FT STRUCTURAL INFORMATION REFER B-1 TO STRUCTURAL (S) PAGES 201ST STREET NE 348.25' FLOOR ELEV 120 S87° 59' 12"E Coast Construction Group 328 N Olympic Ave " 0 '- Arlington, WA 98223 0 4 p. 360-474-0600 BOTTOM OF RAMP 27'-0" AND DRAIN ELEV = 116 f. 360-474-1095 SLOPE CONCRETE AS www.CoastCCG.com REQUIRED FOR DRAINAGE TO OIL/WATER SEPARATOR DRAIN 3 X 6 X 6 OIL / WATER SEPARATOR VAULT ADA VORTCLAREX VCL30 INSTALL PER MANUFACTURER SPECS 10 X 20 X 3 INFILTRATION TRENCH 9"E TOP OF INFILTRATION TRENCH ELEV 115.8 5.' 0' 5 BOTTOM OF TRENCH ELEV 112.8 29 ° 3 9"W N0 5.' 0' 5 29 ° 3 S0 POLYMERS MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 INFILTRATION TRENCH SOIL: FINE TO LOAMY SAND 75 SF OF INFILTRATION PER 100 SF PROJECT INFORMATION MICROGREEN SITE PLAN LOADING DOCK RAMP AREA = 2128 SF POLYMERS SCALE: 1 IN = 30 FT TRENCH AREA REQUIRED = 2128/1000 X 75 = 159.6 SF 7220 201ST STREET NE PROPOSED INFILTRATION TRENCH TO BE 200 SF ARLINGTON, WA 98223 PROPOSED TRENCH 10' X 20' X 3' 348.25' SNOHOMISH COUNTY N87° 59' 12"W PARCEL# 00793300002300 00793300002400 ELEVATIONS PROJECT NO.: TOP OF SHIPPING AREA FLOOR 120.0 X ____________ BOTTOM OF LOADING RAMP 116.0 BOTTOM OF SEPARATOR VAULT INSIDE 110.0 DRAWN BY: TOP OF LID SEPARATOR VAULT 116.5 DS ____________ BOTTOM OF INFILTRATION TRENCH 112.8 CHECKED BY: TOP OF INFILTRATION TRENCH 115.8 TG ____________ REVISIONS: TOP OF STEM WALL BEYOND DOORWAY 4/10/2014 CMU WALL 10'-0" TOP OF TRENCH ELEV 115.8 8" TOP OF SLAB FLOOR 1 FT CLEAN WASHED DRAIN ROCK 1'-0" ELEVATION = 120' THICKEN SLAB TO 8 INCHES AT EDGE WITH EMBEDDED ANGLE IRON CONTINUOUS FILTER 10" (2) 4 INCH PVC PERFORATED DRAIN PIPE FABRIC WITH MIN 4' LAP EACH DIRECTION 2'-0" 2 FT CLEAN WASHED ROCK BLUE GIANT EQUIPMENT BOTTOM OF TRENCH ELEV 112.8 DOCK LEVELER HU7008-30 2'-0" INSTALL PER MANUFACTURERS INFILTRATION TRENCH SECTION SPECIFICATIONS TOP OF RAMP AT WALL ELEVATION = 116' ISSUED: 8'-0" SLOPE TO GRADE APPROXIMATELY 2'-0" 44 INCHES UP IN 56 FEET LEVEL OUT 2 FT THEN SLOPE UP 6 INCHES TO VAULT TOP TOP OF SEPARATOR VAULT ACCESS GRATES ELEV 116.5 TOP OF OUTFALL ELEV 115.0 TOP OF INFILTRATION TRENCH ELEV 115.8 1'-6" TOP OF INLET DRAIN ELEV 115.0 INFILTRATION TRENCH SEPARATOR VAULT BOTTOM OF INFILTRATION TRENCH ELEV 112.8 SHEET NUMBER / TITLE BOTTOM OF SEPARATOR VAULT INSIDE ELEV 110 B-2 SECTION C SCALE: 1/2 IN = 1 FT LOADING RAMP AND STORM WATER MEANS OF EGRESS Lower Offices including existing and new: The occupancy load for the lower floor offices is 3348 square feet / 100 = 34 The required egress width of passageways and doors serving this area is 34 x 0.2 = 6.8" The passageways and doors providing egress for this area exceed the required width Coast Construction Group Upper Offices including existing and new: 328 N Olympic Ave the occupancy load for the upper floor offices is 3554 square feet / 100 = 36 Arlington, WA 98223 The required egress width of stairs serving this are is 36 x 0.3 = 10.8" p. 360-474-0600 The required egress width of doors serving this area is 36 x 0.2 = 7.2" The passageways, doors and stairs providing egress for this area exceed the required width f. 360-474-1095 www.CoastCCG.com New Shipping Area: The occupancy load for the new shipping area is 4948 square feet / 100 = 50 The required egress width of passageways and doors serving this area is 50 x 0.2 = 10" The passageways and doors providing egress for this area exceed the required width 1005.3.1 Stairways. The capacity, in inches (mm), of means of egress stairways shall be calculated by multiplying the occupant load served by such stairway by a means of egress capacity factor of 0.3 inch (7.6 mm) per occupant. Where stairways serve more than one story, only the occupant load of each story considered individually shall be used in calculating the required capacity of the stairways serving that story. 1005.3.2 Other egress components. The capacity, in inches (mm), of means of egress components other than stairways shall be calculated by multiplying the occupant load served by such component by a means of egress capacity factor of 0.2 inch (5.1 mm) per occupant. 1005.4 Continuity. The capacity of the means of egress required from any story of a building shall not be reduced along the path of egress travel until arrival at the public way. 1005.5. Distribution of egress capacity. Where more than one exit, or access to more than one exit, is required, the means of egress shall be configured such that the loss of any one exit, or access to one exit, shall not reduce the available capacity to less than 50 percent of the required capacity. 1006.2 Illumination level. The means of egress illumination level shall not be less than 1 footcandle (11 lux) at the walking surface. POLYMERS Exception: For auditoriums, theaters, concert or opera halls and similar assembly occupancies, the illumination at the walking MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 surface is permitted to be reduced during performances to not less than 0.2 footcandle (2.15 lux), provided that the required illumination is automatically restored upon activation of a premises’ fire alarm system where such system is provided. 1006.3 Emergency power for illumination. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate all of the following areas: 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or more means of egress. 2. Corridors, interior exit stairways and ramps and exit passageways in buildings required to have two or more exits. 3. Exterior egress components at other than their levels of exit discharge until exit discharge is accomplished for buildings required PROJECT INFORMATION to have two or more exits. 4. Interior exit discharge elements, as permitted in Section 1027.1, in buildings required to have two or more exits. MICROGREEN 5. Exterior landings as required by Section 1008.1.6 for exit discharge doorways in buildings required to have two or more exits. POLYMERS The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702. 7220 201ST STREET NE 1006.3.1 Illumination level under emergency power. Emergency lighting facilities shall be arranged to provide initial illumination that ARLINGTON, WA 98223 is at least an average of 1 footcandle (11 lux) and a minimum at any point of 0.1 footcandle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 footcandle (6 lux) average and a minimum at any point of SNOHOMISH COUNTY 0.06 footcandle (0.6 lux) at the end of the emergency lighting time duration. A maximum-to-minimum illumination uniformity ratio of PARCEL# 40 to 1 shall not be exceeded. 00793300002300 1007.3 Stairways. In order to be considered part of an accessible means of egress, a stairway between stories shall have a clear 00793300002400 width of 48 inches (1219 mm) minimum between handrails and shall either incorporate an area of refuge within an enlarged floor- level landing or shall be accessed from either an area of refuge complying with Section 1007.6 or a horizontal exit. Exit access PROJECT NO.: stairways that connect levels in the same story are not permitted as part of an accessible means of egress. X ____________ DEMOLITION GENERAL NOTES DRAWN BY: DS ____________ 1. DEMOLITION CONTRACTOR RESPONSIBLE FOR VERIFICATION OF ALL MATERIALS AND CONSTRUCTION OF ALL FLOOR, WALL, CEILING, AND ROOF ASSEMBLIES. CHECKED BY: TG 2. A SITE SURVEY HAS BEEN PERFORMED REGARDING EXISTING STRUCTURAL COMPONENTS. THE SITE ____________ SURVEY DETERMINED THAT WALLS DESIGNATED TO BE REMOVED ARE NON STRUCTURAL (NON BEARING AND NON SHEARWALL). REVISIONS: 4/10/2014 3. EXISTING CONSTRUCTION THAT IS TO REMAIN SHALL BE PROTECTED FROM DAMAGE AS REQUIRED DURING DEMOLITION OPERATIONS. ANY DAMAGE CAUSED BY THE DEMOLITION SHALL BE REPAIRED AT THE COST OF THE DEMOLITION CONTRACTOR. 4. DEMOLITION CONTRACTOR IS RESPONSIBLE TO MAINTAIN THE CONSTRUCTION FIRE ASSEMBLY RATING FOR ALL EXISTING RATED WALL ASSEMBLIES, ROOF ASSEMBLIES AND/OR SHAFTS. 5. EXISTING UTILITIES TO REMAIN IN SERVICE AND PROTECT THEM DURING SELECTIVE DEMOLITION. 6. CONDUCT DEMOLITION OPERATIONS AND REMOVE DEBRIS TO ENSURE MINIMAL INTERFERENCE WITH ROADS, STREETS, WALKS, AND OTHER ADJACENT OCCUPIED AND USED FACILITIES. ISSUED: 7. PROVIDE TEMPORARY WEATHER PROTECTION, AS REQUIRED, DURING SELECTIVE DEMOLITION AND CONSTRUCTION PROCESS TO ENSURE THAT NO WATER DAMAGE OCCURS TO STRUCTURE, EQUIPMENT, EXTERIOR, OR INTERIOR AREAS. 8. ANY EXISTING FINISHED SURFACES TO REMAIN THAT ARE AFFECTED BY SELECTIVE DEMOLITION SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES UNLESS CONCEALED BY NEW CONSTRUCTION. 9. ALL EXISTING CABINETRY, COUNTERTOPS, SHELVES, ETC. IN AREAS OF DEMOLITION SHALL BE REMOVED, INCLUDING THAT NOT SHOWN SPECIFICALLY SHOWN ON DRAWINGS. 10. CUT AND PATCH FLOOR AS REQUIRED FOR ALL NEW PLUMBING. CAP ABANDONED MECHANICAL BELOW PATCH OF FLOOR SLAB. SHEET NUMBER / TITLE 11. VERIFY ALL MODIFICATIONS OF PLUMBING WITH PLUMBING DRAWINGS. 12. THOROUGHLY CLEAN BUILDING UPON COMPLETION OF SELECTIVE DEMOLITION. C-1 13. TOTAL SCOPE OF DEMOLITION MAY NOT BE COVERED ON THIS SHEET, REVIEW ALL SHEETS IN THE GENERAL NOTES / ENERGY CODE CONSTRUCTION DOCUMENTS TO DETERMINE TOTAL SCOPE OF DEMOLITION. ACCESSIBILITY ACCESSIBLE ROUTES 302.1 General. Floor surfaces shall be stable, firm, and 402.2 Components. Accessible routes shall consist of slip resistant, and shall comply with Section 302. one or more of the following components: Walking surfaces Coast Construction Group Changes in level in floor surfaces shall comply with with a slope not steeper than 1 :20, doors and 328 N Olympic Ave Section 303. doorways, ramps, curb ramps excluding the flared sides, elevators, and platform lifts. All components of an Arlington, WA 98223 302.2 Carpet. Carpet or carpet tile shall be securely accessible route shall comply with the applicable portions p. 360-474-0600 attached and shall have a firm cushion, pad, or backing of this standard. f. 360-474-1095 or no cushion or pad. Carpet or carpet tile shall have a www.CoastCCG.com level loop, textured loop, level cut pile, or level cut/uncut 403.5 Clear Width. The clear width of an accessible pile texture. The pile shall be 1/2 inch (13 mm) maximum route shall be 36 inches (915 mm) minimum. in height. Exposed edges of carpet shall be fastened to the floor and shall have trim along the entire length of 404.2.2 Clear Width. Doorways shall have a clear the exposed edge. Carpet edge trim shall comply with opening width of 32 inches (815 mm) minimum. Section 303. Clear opening width of doorways with swinging doors shall be measured between the face of door and 302.3 Openings. Openings in floor surfaces shall be of stop, with the door open 90 degrees. Openings more a size that does not permit the passage of a 1/2 inch (13 than 24 inches (610 mm) in depth at doors and doorways mm) diameter sphere, except as allowed in Sections without doors shall provide a clear opening 407.4.3, 408.4.3, 409.4.3, 410.4, and 805.10. Elongated width of 36 inches (915 mm) minimum. There shall openings shall be placed so that the long dimension be no projections into the clear opening width lower is perpendicular to the predominant direction of than 34 inches (865 mm) above the floor. Projections travel. into the clear opening width between 34 inches (865 mm) and 80 inches (2030 mm) above the floor shall 303.1 General. Changes in level in floor surfaces shall not exceed 4 inches (100 mm). comply with Section 303. EXCEPTIONS: 303.2 Vertical. Changes in level of 1/4 inch (6.4 mm) 1. Door closers and door stops shall be permitted maximum in height shall be permitted to be vertical. to be 78 inches (1980 mm) minimum 303.3 Beveled. Changes in level greater than 1/4 inch above the floor. (6.4 mm) in height and not more than 1/2 inch (13 mm) 2. In alterations, a projection of 5/s inch (16 maximum in height shall be beveled with a slope not mm) maximum into the required clear opening POLYMERS steeper than 1 :2. width shall be permitted for the latch side MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 303.4 Ramps. Changes in level greater than 1/2 inch (13 stop. mm) in height shall be ramped and shall comply with Section 405 or 406. 404.2.6 Door Hardware. Handles, pulls, latches, locks, and other operable parts on accessible doors 304.2 Floor Surface. Floor surfaces of a turning space shall have a shape that is easy to grasp with one shall comply with Section 302. Changes in level are not hand and does not require tight grasping, pinching, permitted within the turning space. or twisting of the wrist to operate. Operable parts of EXCEPTION: Slopes not steeper than 1 :48 shall be such hardware shall be 34 inches (865 mm) minimum permitted. and 48 inches (1220 mm) maximum above the 304.3 Size. Turning spaces shall comply with Section floor. Where sliding doors are in the fully open position, PROJECT INFORMATION 304.3.1 or 304.3.2. operating hardware shall be exposed and usable from both sides. MICROGREEN 304.3.1 Circular Space. The turning space shall EXCEPTION: Locks used only for security purposes be a circular space with a 60-inch (1525 mm) minimum and not used for normal operation shall not POLYMERS diameter. The turning space shall be permitted be required to comply with Section 404.2.6. to include knee and toe clearance complying 7220 201ST STREET NE with Section 306. ARLINGTON, WA 98223 304.3.2 T-Shaped Space. The turning space shall be a T-shaped space within a 60-inch (1525 mm) SNOHOMISH COUNTY minimum square, with arms and base 36 inches GENERAL SITE AND BUILDING ELEMENTS PARCEL# (915 mm) minimum in width. Each arm of the T 00793300002300 shall be clear of obstructions 12 inches (305 mm) 502.2 Vehicle Space Size. Car parking spaces shall be 00793300002400 minimum in each direction, and the base shall be 96 inches (2440 mm) minimum in width. Van parking clear of obstructions 24 inches (610 mm) minimum. spaces shall be 132 inches (3350 mm) minimum in The turning space shall be permitted to width. PROJECT NO.: include knee and toe clearance complying with EXCEPTION: Van parking spaces shall be permitted X Section 306 only at the end of either the base or to be 96 inches (2440 mm) minimum in width where ____________ one arm. the adjacent access aisle is 96 inches (2440 mm) minimum in width. DRAWN BY: 305.2 Floor Surfaces. Floor surfaces of a clear floor DS space shall comply with Section 302. Changes in level 502.3 Vehicle Space Marking. Car and van parking ____________ are not permitted within the clear floor space. spaces shall be marked to define the width. Where parking spaces are marked with lines, the width measurements CHECKED BY: 306.2.1 General. Space beneath an element of parking spaces and adjacent access TG between the floor and 9 inches (230 mm) above aisles shall be made from the centerline of the markings. ____________ the floor shall be considered toe clearance and shall comply with Section 306.2. 502.4.1 Location. Access aisles shall adjoin an accessible route. Two parking spaces shall be permitted REVISIONS: 306.3.1 General. Space beneath an element to share a common access aisle. Access 4/10/2014 between 9 inches (230 mm) and 27 inches (685 aisles shall not overlap with the vehicular way. Parking mm) above the floor shall be considered knee spaces shall be permitted to have access aisles clearance and shall comply with Section 306.3. placed on either side of the car or van parking space. Van parking spaces that are angled shall have access aisles located on the passenger side of the parking space. 502.4.2 Width. Access aisles serving car and van parking spaces shall be 60 inches (1525 mm) minimum in width. 502.4.3 Length. Access aisles shall extend the full length of the parking spaces they serve. ISSUED: SHEET NUMBER / TITLE C-2 ACCESSIBLE NOTES AND DETAILS Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com POLYMERS MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 OVERVIEW SCALE: NTS PROJECT INFORMATION MICROGREEN POLYMERS 7220 201ST STREET NE ARLINGTON, WA 98223 SNOHOMISH COUNTY PARCEL# 00793300002300 00793300002400 PROJECT NO.: X ____________ DRAWN BY: DS ____________ CHECKED BY: TG ____________ REVISIONS: 4/10/2014 WEST ELEVATION SCALE: 1 IN = 10 FT ISSUED: SHEET NUMBER / TITLE SOUTH ELEVATION SCALE: 1 IN = 10 FT E-1 EXISTING BUILDING ELEVATIONS 25'-0" 250'-0" 24'-11" Coast Construction Group 328 N Olympic Ave 5040FX Arlington, WA 98223 5'-8 1/2" 18'-0" EXISTING ROLLUP p. 360-474-0600 5'-0" 7'-6" f. 360-474-1095 www.CoastCCG.com 6'-0" 6040FX 15'-6" 6" 7'-3" 6'-0" 6040FX 36'-7" 4'-0" 49'-0" 6'-0" 6040FX 6" 6'-0" 6040FX B UP 5'-0" C 6'-0" 5040FX EXISTING AND DEMOLITION 6040FX 11'-4" A EXISITNG WALL TO BE REMOVED 2'-8" 2'-2" B EXISTING CABINETRY AND / OR PLUMBING TO BE REMOVED POLYMERS 12'-0" 4040FX C REMOVE WALL SECTION FOR NEW OPENING MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 9'-6 1/2" D REMOVE BOTTOM STEPS AND LANDING FOR NEW BOTTOM STAIR SECTION 4'-6 1/2" 14'-9" 4040FX 110'-0" 14'-0" 7'-2" 5'-1 1/2" 9'-4" EXISTING ROLLUP UPD 4040FX 4'-2" C 1'-9" 42'-0" 4'-9" 7'-6 1/2" 6'-0" 6040FX PROJECT INFORMATION 19'-3" MEN 4'-9" MICROGREEN ADA POLYMERS 6'-0" 6040FX EXISITING PRINT ROOM 7220 201ST STREET NE 2'-4" 4'-9" 26'-8" ARLINGTON, WA 98223 ADA 19'-9 1/2" 16'-3" SNOHOMISH COUNTY 6'-0" 11'-4 1/2" 6040FX WOMEN 38'-8" PARCEL# 11'-1 1/2" 00793300002300 3'-5" 00793300002400 6'-0" 6040FX A 9'-6" PROJECT NO.: A EXISITNG 11'-3" X PRINT 9'-2" ____________ 7'-0" A EXISTING ROLLUP STORAGE 100'-6" B DRAWN BY: 5040FX 5040FX 5040FX 5040FX 5040FX 40'-9" 75'-0" DS 12'-0" 50'-0" ____________ 49'-8" X 16'-0" EXISTING SHED BUILDING TO BE REMOVED CHECKED BY: 15'-11" EXISTING LOWER FLOOR TG 25'-1" ____________ AND DEMOLITION PLAN SCALE: 1 IN = 10 FT 30'-0" REVISIONS: 4/10/2014 EXISTING TRUCK RAMP TO REMAIN AT THIS 10'-0" LOCATION WITH PARTIAL DEMOLITION AND REBUILD 10'-0" EXISTING COLUMN ISSUED: SHEET NUMBER / TITLE E-2 EXISTING LOWER FLOOR PLAN 25'-0" 250'-0" Coast Construction Group 328 N Olympic Ave 5040FX 5040FX Arlington, WA 98223 5'-0" p. 360-474-0600 f. 360-474-1095 11'-0" www.CoastCCG.com 6'-0" 6040FX 6" 9'-10 1/2" 14'-4 1/2" 6'-0" 6040FX 4'-0" 16'-4" DN 19'-0 1/2" 6'-0" 6040FX 10'-2" 6040FX 6" 6'-0" 6040FX 5'-0" 17'-8 1/2" 6'-0" 6040FX 10'-9" EXISTING AND DEMOLITION DN A EXISITNG WALL TO BE REMOVED B EXISTING CABINETRY AND / OR PLUMBING TO BE REMOVED POLYMERS MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 C REMOVE WALL SECTION FOR NEW OPENING 9'-6" 4'-0" D REMOVE BOTTOM STEPS AND LANDING FOR NEW BOTTOM STAIR SECTION 110'-0" 14'-0" OPEN TO BELOW D 6'-6" 6'-0" 6040FX 10'-4" EXISTING RAILING PROJECT INFORMATION 6'-6" 4'-9" MICROGREEN 10'-0" POLYMERS 6'-0" 6040FX 10'-4" UP 9'-6" 7220 201ST STREET NE 11'-5" 4'-9" 5 STEPS UP TO ARLINGTON, WA 98223 EXISTING STORAGE MEZZANINE SNOHOMISH COUNTY 6'-0" 10'-4" 6040FX EGRESS 4'-2" PARCEL# B A A 00793300002300 3'-5" 00793300002400 EXISTING STAIRS 48" WIDE 6'-0" 6040FX 16'-4" EGRESS ROUTE PROJECT NO.: 14'-4" X EXISTING CONFERENCE ROOM ____________ 7'-0" DRAWN BY: 5040FX 5040FX DS ____________ EXISTING UPPER FLOOR AND DEMOLITION PLAN CHECKED BY: SCALE: 1 IN = 10 FT TG ____________ REVISIONS: 4/10/2014 ISSUED: SHEET NUMBER / TITLE E-3 EXISTING UPPER FLOOR PLAN SITE PLAN INFORMATION PROJECT INFORMATION 348.25' 201ST STREET NE S87° 59' 12"E MICROGREEN Coast Construction Group " 0 '- 328 N Olympic Ave 0 PROJECT INFO 4 Arlington, WA 98223 27'-0" TAX ACCOUNT NUMBER: 00793300002300 / 00793300002400 p. 360-474-0600 WATER SERVICE: CITY OF ARLINGTON POLYMERS f. 360-474-1095 SEWER SERVICE: CITY OF ARLINGTON www.CoastCCG.com FIRE DISTRICT: CITY OF ARLINGTON PROJECT AREA: 2.5 ACRES 7220 201ST STREET NE SITE ADDRESS: 7220 201ST STREET NE, ARLINGTON, WA ZONING / COMP. PLAN: G.I. - GENERAL INDUSTRIAL ARLINGTON, WA 98223 PROPOSED LAND USE: G.I. - GENERAL INDUSTRIAL DATUM (VERT / HORIZ): NAVD 88 / NAD 83 ADA PROJECT LOCATION MAP DEVELOPER EXISTING BUILDING AREA COAST CONSTRUCTION GROUP TREVOR GASKIN 201ST STREET NE MICROGREEN POLYMERS E 328 OLYMPIC AVE " 59 ARLINGTON, WA 98223 '.5 ' 9 0 (425) 923-0277 2 °3 W 0 "9 N '. 5 5 ' 9 0 2 3 ° 0 PROPOSED NEW AREA S CONTACT / ENGINEER HALE MILLIGAN & ASSOCIATED LLC POLYMERS KELLI HALE, PE MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 307 OLYMPIC AVE, SUITE 209 ARLINGTON, WA 98223 (360) 474-4624 LEGAL DESCRIPTION SECTION 14 TOWNSHIP 31 RANGE 05 QUARTER NW PROJECT INFORMATION JENSEN BUSINESS PARK, PHASE 2 BLK 000 D-00 LOT 23 JENSEN BUSINESS PARK, PHASE 2 BLK 000 D-00 LOT 24 MICROGREEN POLYMERS SCALE: 1 IN = 30 FT 7220 201ST STREET NE ARLINGTON, WA 98223 348.25' N87° 59' 12"W SNOHOMISH COUNTY PARCEL# GENERAL NOTES CODE INFORMATION PROJECT CONTACTS SHEET INDEX 00793300002300 00793300002400 DESIGNER T-1 TITLE SHEET PROJECT NO.: ALL CONSTRUCTION FOR THIS PROJECT 1. CONTRACTOR SHALL VERIFY AND COORDINATE ALL DRAWINGS AND REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR SHALL COMPLY WITH THE FOLLOWING: COAST CONSTRUCTION GROUP X ____________ CLARIFICATION AND RESOLUTION PRIOR TO PERFORMING ANY WORK. DISCREPANCIES AMONG THE DRAWINGS OR BETWEEN THE 328 N OLYMPIC AVE PROPOSED CONSTRUCTION PAGES DRAWINGS AND THE SITE CONDITIONS DO NOT QUALIFY AS GROUNDS FOR COMPENSATION FROM THE OWNER, PROFESSIONALS FOR 2012 INTERNATIONAL BUILDING CODE ARLINGTON, WA 98223 DRAWN BY: ERRORS IN BUILD-OUT OR INSTALLATION. 2012 INTERNATIONAL MECHANICAL CODE O 360-474-0600 DS 2012 INTERNATIONAL FIRE CODE F 360-474-1095 A-1 BUILDING ELEVATIONS ____________ 2012 INTERNATIONAL FUEL GAS CODE 2. DO NOT SCALE THE DRAWING. 2012 UNIFORM PLUMBING CODE CONTACT: TREVOR GASKIN A-2 LOWER FLOOR PLAN CHECKED BY: NATIONAL ELECTRICAL CODE (NFPA 70) EMAIL: TREVOR@COASTCCG.COM A-3 UPPER FLOOR PLAN 3. ALL WORK SHALL CONFORM TO THE LATEST ADOPTED ISSUES OF ALL APPLICABLE CODES AND LOCAL REGULATIONS. 2009 ICC/ANSI A117.1-09 ____________TG 2012 WASHINGTON STATE ENERGY CODE A-4 DOORS AND WINDOWS CONTRACTOR 4. ALL NEW WORK SHALL BE IN COMPLIANCE WITH FEDERAL, STATE, AND LOCAL REGULATIONS. COAST CONSTRUCTION GROUP A-5 LIGHTING AND CEILING 328 N OLYMPIC AVE A-6 HVAC AND VENTILATION REVISIONS: OCCUPANCY TYPE - F1 / B 5. ALL DIMENSIONS ARE INSIDE ROOM CLEAR DIMENSIONS, UNLESS NOTED OTHERWISE. CONSTRUCTION TYPE - VB ARLINGTON, WA 98223 A-7 PLUMBING AND FIXTURES 4/10/2014 SPRINKLERED - YES O 360-474-0600 FIRE ALARMED - YES A-8 FLOOR AND ROOF FRAMING 6. CONTRACTOR SHALL PROVIDE ALL NEEDED BLOCKING FOR ATTACHMENT OF WALL-HUNG ITEMS. F 360-474-1095 CONTACT: TREVOR GASKIN B-1 BUILDING SECTIONS 7. CONTRACTOR SHALL PROVIDE SEISMIC BRACING FOR CEILING SYSTEM & OTHER SUSPENDED FIXTURES AS NECESSARY. SQUARE FOOTAGE SUMMARY EMAIL: TREVOR@COASTCCG.COM B-2 LOADING RAMP AND STORM WATER C-1 GENERAL NOTES / ENERGY CODE 8. CONTRACTOR SHALL PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY THE FIRE DEPARTMENT. EXISTING MANUFACTURING AREA 27,500 ENGINEER EXISTING MAIN FLOOR OFFICE AREA 2,639 C-2 ACCESSIBLE NOTES AND DETAILS B&T DESIGN AND ENGINEERING EXISTING UPPER FLOOR OFFICE AREA 2,485 9. EXTERIOR SIGNAGE TO BE PROVIDED BY THE OWNER UNDER SEPARATE CONTRACT. P.O. BOX 595 TOTAL EXISTING FLOOR AREA 32,624 NEW SHIPPING AREA 4,948 ISSAQUAH, WA 98027 EXISTING BUILDING AND DEMO PAGES 10. CONTRACTOR SHALL COORDINATE WITH OWNER AND RECONCILE WITH PLANS TO DETERMINE SCOPE OF DEMO WORK. NEW MAIN FLOOR OFFICE AREA 709 O 425-557-0779 NEW UPPER OFFICE AREA 709 F 425-557-0765 TOTAL NEW FLOOR AREA 6,366 CONTACT: JIM TRUEBLOOD E-1 EXISITNG BUILDING ELEVATIONS ISSUED: TOTAL FLOOR AREA AFTER ADDITION 38,990 EMAIL: JIM@BNTENGR.COM E-2 EXISTING LOWER FLOOR E-3 EXISTING UPPER FLOOR OCCUPANCY LOAD TENANT MICROGREEN POLYMERS PER IBC TABLE 1004.1.2 STRUCTURAL AND ENGINEERING 7220 201ST STREET NE BUSINESS FACTOR = 100 ARLINGTON, WA 98223 INDUSTRIAL FACTOR = 100 TYPE F1 INDUSTRIAL AREA 32,448 / 100 = 324 O 360-435-7400 S1.1 FOUNDATION PLAN TYPE B BUSINESS AREA 6,542 / 100 = 65 F 360-435-0248 S1.2 SECOND FLOOR FRAMING PLAN CONTACT: TONY LASALATA S1.3 ROOF FRAMING PLAN EMAIL: TONY.LASALATA@MICROGREENINC.COM S2.1 STANDARD DETAILS AND NOTES OWNER S2.2 STANDARD DETAILS JENSEN BUSINESS PARK, LLC SHEET NUMBER / TITLE S3.1 FOUNDATION DETAILS 20613 OLD BURN HILL RD S4.1 FLOOR FRAMING DETAILS ARLINGTON, WA 98223 O 425-356-7082 S5.1 ROOF FRAMING DETAILS F 360-652-5161 T-1 CONTACT: DEAN JENSEN EMAIL: DAJEX54@MSN.CO Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com NEW TPO ROOF WITH SCUPPERS AND DOWNSPOUTS STANDING SEAM METAL ROOFING TO MATCH EXISTING WITH GUTTERS AND DOWNSPOUTS BUILDING OVERVIEW POLYMERS NTS MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 LOADING DOCK RAMP TO BE 48" LOWER THAN FINISHED FLOOR PROJECT INFORMATION MICROGREEN POLYMERS 7220 201ST STREET NE ARLINGTON, WA 98223 UPPER FLOOR CEILING HT CMU WALL HT SNOHOMISH COUNTY PARCEL# 00793300002300 00793300002400 20'-1" 19'-0" PROJECT NO.: X ____________ DRAWN BY: DS WEST ELEVATION ____________ SCALE: 1 IN = 10 FT CHECKED BY: TG ____________ REVISIONS: 4/10/2014 ISSUED: SOUTH ELEVATION SCALE: 1 IN = 10 FT SHEET NUMBER / TITLE NORTH ELEVATION EAST ELEVATION A-1 SCALE: 1 IN = 20 FT SCALE: 1 IN = 20 FT ELEVATIONS 25'-0" 250'-0" 24'-11" Coast Construction Group 3070 5040FX 328 N Olympic Ave A A Arlington, WA 98223 5'-8 1/2" 18'-0" EXISTING ROLLUP 5'-0" p. 360-474-0600 7'-6" f. 360-474-1095 3068 www.CoastCCG.com 6'-0" 6040FX 15'-6" 6" 7'-3" 6'-0" 3068 6040FX A 3068 36'-7" 4'-0" 49'-0" 6'-0" 6040FX 6" EXISTING - NO WORK IN THIS AREA 6'-0" 6040FX 3'-6" 5068 UP 5'-0" H REPLACE SINK AND EXISTING COUNTER 6'-0" 5040FX WALL LEGEND 6040FX 11'-4" A EXISTING 6" CONCRETE TILT UP TYPE WALL 2'-8" 3068 3068 2'-2" B 8" CMU BLOCK WALL POLYMERS 12'-0" 3068 C 7220 201ST STREET NE ARLINGTON, WA 98223 4040FX 2X6 AT 16" OC WOOD FRAMED EXTERIOR WALL WITH 5/8 GWB INT AND STUCCO EXT MICROGREEN 9'-6 1/2" D 2X6 AT 16" OC WOOD FRAMED INTERIOR WALL WITH 5/8 GWB BOTH SIDES 14'-0" 3070 4'-6 1/2" 14'-9" 4040FX 110'-0" 7'-2" 5'-1 1/2" 9'-4" E 2X4 AT 16" OC WOOD FRAMED INTERIOR WALL WITH 5/8 GWB BOTH SIDES EXISTING ROLLUP 4040FX UP 3068 4'-2" F 2X3 AT 16" OC WOOD FRAMED INTERIOR WALL WITH 5/8 GWB ONE SIDE 3068 5068 1'-9" G NEW WALL TO BE FRAMED IN EXISTING AREA 42'-0" 4'-9" H NEW OPENING / DOOR IN EXISTING WALL 7'-6 1/2" 6'-0" 6040FX 8040FX 3068 H 3068 D PROJECT INFORMATION 19'-3" MEN 3068 4'-9" G G MICROGREEN 9'-9" 3068 ADA POLYMERS 6'-0" 3068 6040FX 10'-3" G D G D 7220 201ST STREET NE 2'-4" 3068 4'-9" G 26'-8" ARLINGTON, WA 98223 ADA G 47'-0" 9'-8 1/2" 3068 G 5'-2" 14'-4" 16'-3" SNOHOMISH COUNTY 6'-0" 6040FX 11'-4 1/2" WOMEN 3068 G 38'-8" 10'-3" 3'-10" TOP OF EXISITING FINISHED FLOOR ELEVATION = 120 FT PARCEL# 3'-5" 11'-1 1/2" E 00793300002300 G 9'-0" 3068 3068 00793300002400 3'-8 1/2" G 6'-11 1/2" 6'-0" 9'-0" 15'-3" G G 7'-9 1/2" 6040FX 3068 SHIPPING G TEAM 9'-6" PROJECT NO.: 13'-0" ROOM G G OFFICE X 11'-0" 11'-3" 9'-2" ADA NEW 12 X 12 ROLLUP ____________ 7'-0" EXISTING ROLLUP H H 100'-6" EXISTING AREA F 10'-9 1/2" F 12 W X 12 H H 12 W X 12 H EXISTING AREA 3068 A 3068 5070 3070 A 3070 3070 A A DRAWN BY: NEW AREA F F F NEW AREA 74'-9" 75'-0" 4'-3" 3068 4'-6" 4'-6 1/2" 4'-6" 11'-5" 12'-0" 11'-0" 12'-0" 50'-0" DS KEEP WINDOW ____________ CLOSE OFF 3068 D D WINDOW 6'-0" 6040FX 41'-9 1/2" CHECKED BY: 14'-4 1/2" 15'-11" 9 W X 12 H 5040FX 9'-4 1/2" OFFICE ____________TG F 14'-0" 4'-6" E 5068 3068 E EXISTING AREA 8'-9" 4040FX NEW 9 X 12 ROLLUP 24'-10 13/16" 30'-0" C B 30'-0" 30'-0" D REVISIONS: TOP OF FINISHED FLOOR ELEVATION = 120 FT A5 10 ROLLUP 10 ROLLUP 10 ROLLUP10 H B 10 H 10 H 4/10/2014 D X 9 X X 9 X X 9 X W 12'-0" W W 6'-0" 5068 9 9 9 NEW AREA 6040FX 14'-8" 30'-0" EXISTING AREA 14'-10 1/2" TOP OF TRUCKK LOADING RAMPCANTILEVER TRUSSES AT THIS BEAM LINE 12'-0" 10'-0" F AT WALL ELEVATION TO BE 116 FT 5'-0" EXISTING AREA 10'-0" EXISTING ROLLUP B 5'-7 3/16" C 12'-0" ROOF BEAM 5040FX 3640FX 3070 6040FX 3070 3070 NEW AREA 2'-5" 9" 3'-0" 5'-0" 9'-0" 3'-6" 3'-0" 15'-0 1/2" 3'-0" 12'-0" NOTE: SEE DETAILS FOR OIL EXISTING COLUMN WATER SEPARATOR VAULT B TOP OF FINISHED FLOOR ELEVATION = 120 FT 25'-0" 66'-3 3/16" 62'-4 1/8" 15'-0" 60'-0" A 36'-0" B A5 E A5 B A5 12'-0" (1) EXISTING LOADIN RAMP (2) NEW LOADING RAMPS ROOF BEAM 30'-0" ISSUED: 15'-0" 12 X 14 ROLLUP B 12 W X 14 H 2'-0" 8'-2 11/16" 12'-0" 22'-2 11/16" F 16'-0" PROPOSED LOWER FLOOR A5 C SCALE: 1 IN = 10 FT A6 SHEET NUMBER / TITLE A-2 PROPOSED LOWER FLOOR 25'-0" 250'-0" Coast Construction Group 5040FX 5040FX 328 N Olympic Ave A A Arlington, WA 98223 5'-0" p. 360-474-0600 f. 360-474-1095 11'-0" www.CoastCCG.com 6'-0" 6040FX 3068 6" 9'-10 1/2" 14'-4 1/2" 6'-0" 6040FX NEW DESK A 10'-0 1/2" 3068 AND COUNTER 4'-0" 16'-4" 3068 D1 DN 6'-0" 6040FX 6040FX WALL LEGEND 9'-0" 6" 3'-7 1/2" A EXISTING 6" CONCRETE TILT UP TYPE WALL 3068 6'-0" 6040FX B 8" CMU BLOCK WALL 10'-0" G 3068 C 2X6 AT 16" OC WOOD FRAMED EXTERIOR WALL WITH 5/8 GWB INT AND STUCCO EXT 5'-0" G D 2X6 AT 16" OC WOOD FRAMED INTERIOR WALL WITH 5/8 GWB BOTH SIDES 10'-2" 17'-8 1/2" E 2X4 AT 16" OC WOOD FRAMED INTERIOR WALL WITH 5/8 GWB BOTH SIDES 6'-0" 6040FX 10'-9" F 2X3 AT 16" OC WOOD FRAMED INTERIOR WALL WITH 5/8 GWB ONE SIDE 3068 DN G NEW WALL TO BE FRAMED IN EXISTING AREA POLYMERS H NEW OPENING / DOOR IN EXISTING WALL 3068 MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 9'-6" 4'-0" 110'-0" 14'-0" OPEN TO BELOW 3068 3068 6'-6" 6'-0" 6040FX 10'-4" EXISTING RAILING PROJECT INFORMATION 6'-6" 4'-9" 3068 3068 MICROGREEN 10'-0" POLYMERS 6'-0" 10'-4" 3068 6040FX UP 11'-5" 7220 201ST STREET NE 4'-9" 5 STEPS UP TO ARLINGTON, WA 98223 3068 EXISTING STORAGE MEZZANINE 6'-0" SNOHOMISH COUNTY 6040FX 11'-10" 3068 EGRESS 4'-2" PARCEL# 00793300002300 3'-5" G REPLACE EXISTING 00793300002400 SINK AND CABINET 3068 5068 EXISTING STAIRS 48" WIDE 6'-0" 6040FX G 11'-0 1/2" 4'-0" 10'-5 1/2" EGRESS ROUTE PROJECT NO.: 12'-10" G G G X 7'-0" ____________ 9'-6" 3068STORAGE 5'-0" EXISTING AREA A H A DRAWN BY: NEW AREA F F 4'-3" 3068 3068 DS ____________ 6'-0" 13'-3" CHECKED BY: 6040FX 9'-6" 4'-0" 10'-5 1/2" ____________TG 4'-3" E 3068 5'-0" B REVISIONS: 5040FX C 4/10/2014 4'-0" 16'-0" F 5'-0" 5040FX 1'-6" C 5040FX 5040FX 3'-0" 5'-0" 9'-0" 5'-0" 3'-8" PROPOSED UPPER FLOOR SCALE: 1 IN = 10 FT ISSUED: SHEET NUMBER / TITLE A-3 PROPOSED UPPER FLOOR Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 100 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com 100 DN 300 B 100 UP 100 DN 100 100 100 100 POLYMERS 60 MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 100 UP 100 100 100 100 40 100 100 100 100 100 PROJECT INFORMATION 300 300 B MICROGREEN B POLYMERS 100 300 B 7220 201ST STREET NE 100 300 ARLINGTON, WA 98223 B SNOHOMISH COUNTY 100 300 PARCEL# 100 00793300002300 00793300002400 100 300 A EXISTING AREA PROJECT NO.: 500 500 B A NEW AREA X EXISTING AREA EXISTING 300 300 ____________ B B NEW AREA 200 600 600 A 100 100 100 10 DRAWN BY: 800 DS 10 300 ____________ B 60 CHECKED BY: 300 70 B TG ____________ 50 300 B 700 700 700 REVISIONS: 10 70 4/10/2014 70 70 20 30 10 400 400 400 C C C LOWER FLOOR UPPER FLOOR ISSUED: 900 SHEET NUMBER / TITLE A-4 DOORS AND WINDOWS Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com DN UP DN POLYMERS MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 UP PROJECT INFORMATION MICROGREEN POLYMERS 3 BULB RECESSED TROFFER FIXTURE 7220 201ST STREET NE 2 BULB TS FIXTURE ARLINGTON, WA 98223 6 BULB T5 FIXTURE EXTERIOR 54 WATT LED SNOHOMISH COUNTY WALL PACKS PARCEL# EXISTING LIGHTING TO 00793300002300 REMAIN IN THIS ROOM 00793300002400 PROJECT NO.: X ____________ EXISTING AREA DRAWN BY: NEW AREA DS ____________ CHECKED BY: TG ____________ EXISTING AREA / NO WORK IN THIS AREA REVISIONS: 4/10/2014 LOWER FLOOR UPPER FLOOR ISSUED: LIGHTING AND CEILING SCALE: 1 IN = 10 FT SHEET NUMBER / TITLE A-5 LIGHTING AND ELECTRIC Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com DN UP DN POLYMERS MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 UP PROJECT INFORMATION MICROGREEN POLYMERS 7220 201ST STREET NE ARLINGTON, WA 98223 SNOHOMISH COUNTY PARCEL# 00793300002300 00793300002400 PROJECT NO.: X ____________ DRAWN BY: R R R DS ____________ W R CHECKED BY: R W W W ____________TG EXISTING AREA / NO WORK IN THIS AREA REVISIONS: THERMOSTAT R THERMOSTAT W 4/10/2014 W R W W W OUTDOOR UNITS LOCATED LOWER FLOOR UPPER FLOOR ALONG THIS WALL W WARM AIR DIFFUSER EQUIPMENT (LOWER FLOOR): W WARM AIR DIFFUSER AMERICAN STANDARD 2-1/2 TON HEAT PUMP SYSTEM AIR HANDLER: TAM7A0B30H21, WITH 10 KW STRIP HEAT R RETURN AIR DIFFUSER HEAT PUMP: 4A6H3030 R RETURN AIR DIFFUSER ISSUED: EQUIPMENT (UPPER FLOOR): AMERICAN STANDARD 2 TON HEAT PUMP SYSTEM AIR HANDLER: TAM7A0B30H21, WITH 10 KW STRIP HEAT HEAT PUMP: 4A6H3024 HVAC AND VENTILATION SCALE: 1 IN = 10 FT SHEET NUMBER / TITLE A-6 HVAC AND VENTILATION Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com DN UP PLUMBING FIXTURES C A EXISTING / NO CHANGE DN B NEW SINK AND FAUCET POLYMERS MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 C REPLACE EXISTING SINK AND FAUCET UP D NEW WALL HUNG LAV, WATER CLOSET, URINAL, AND FLOOR DRAIN. ALL TO BE ADA COMPLIANT. A PROJECT INFORMATION A A MICROGREEN POLYMERS 7220 201ST STREET NE NOTE: ARLINGTON, WA 98223 3" DRAIN A RELOCATE EXISTING SERVICE LINES AS REQUIRED SNOHOMISH COUNTY C PARCEL# 00793300002300 CUT CONCRETE AND TIE INTO EXISTING WASTE LINE 00793300002400 H / W C / W C / W H / W 2" DRAIN PROJECT NO.: C / W C / W C / W H / W C / W C / W 2" DRAIN C / W H / W X C / W 2" DRAIN ____________ H / W H / W H / W H / W C / W H / W DRAWN BY: D DS ____________ C / W H / W CHECKED BY: TG C / W H / W ____________ EXISTING AREA / NO WORK IN THIS AREA B C / W H / W REVISIONS: C / W C / W 4/10/2014 H / W H / W H / W LOWER FLOOR UPPER FLOOR ISSUED: PLUMBING AND FIXTURES SCALE: 1 IN = 10 FT SHEET NUMBER / TITLE A-7 PLUMBING AND FIXTURES Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com 100'-6" E S3.1 EXISTING AREA NEW AREA SINGLE JOIST AT THIS SPAN 5'-2" CEILING FRAMING TO BE (2) 2X12 HF#2 AT 16" OC WITH 5/4 T&G SHEATING EXISTING AREA / NO WORK IN THIS AREA 30'-0" 4X12 DF#2 HEADER 4X12 DF#2 AT DOOR, WINDOW, 24'-2" AND HALLWAY 12'-0" 5'-7 3/16" E S3.1 19'-11" 22'-6 1/2" POLYMERS MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 25'-0" 66'-3 3/16" 50'-4 1/8" FLOOR AND STORAGE 30'-0" CEILING FRAMING SCALE: 1 IN = 10 FT PROJECT INFORMATION MICROGREEN POLYMERS 22'-2 11/16" 7220 201ST STREET NE ARLINGTON, WA 98223 SNOHOMISH COUNTY PARCEL# 00793300002300 00793300002400 PROJECT NO.: X ____________ DRAWN BY: DS ____________ 100'-6" CHECKED BY: EXISTING AREA NEW AREA TG ____________ REVISIONS: MANUFACTURED TRUSSES AT 24" OC 4/10/2014 WITH 3:12 ROOF PITCH EXISTING AREA / NO WORK IN THIS AREA 30'-0" 12'-0" CANTILEVER ROOF TRUSSES AT THIS LOCATION MANUFACTURED TRUSSES AT 24" OC WITH 4:12 ROOF PITCH 5'-7 3/16" 2X12 HF#2 RAFTERS AT 24" OC ISSUED: 25'-0" 66'-3 3/16" 50'-4 1/8" 30'-0" ROOF FRAMING SCALE: 1 IN = 10 FT 22'-2 11/16" FOR ADDITIONAL FRAMING AND SHEET NUMBER / TITLE STRUCTURAL INFORMATION REFER TO STRUCTURAL (S) PAGES A-8 FLOOR AND ROOF FRAMING PLAN Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com 3:12 ROOF PITCH PROVIDE 8 INCH GAP 8" TO WALL FOR EXISTING MANUFACTURED TRUSSES AT 24" OC (HIP ROOF) 12 INCH HEEL HEIGHT CONDUIT AT WALL AT TRUSS BEARING MAUNFACTURED HIPSET TRUSSES 5/8 GWB AT CEILING 25'-0" SOFFIT INTEGRATED INTO TRUSS DESIGN EXISTING 6" 33'-0" 48" CONCRETE TILT UP TYPE WALL 114 3/4" 30'-0" 114 3/4" 241" NEW CMU WALL 241" 2X6 AT 16" OC WOOD FRAMED WALL 36" 5/4" T&G FLOOR SHEATHING 5/4 T&G FLOOR SHEATHING CMU WALL MAUNUFACTURED FLOOR 22" 22" DEEP FLOOR TRUSSES AT 24" OC 22" TRUSSES AT 24" OC 19'-0" 2X6 AT 16" OC WOOD FRAMED WALL POLYMERS 5/8 GWB AT CEILING MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 EXISTING 6 INCH TILT UP WALL 48" 123 1/2" 123 1/2" 103" 103" NEW AREA EXISTING AREA 36" OUTSIDE WALL HEIGHT FOR 1 1/2" TOP CHORD BEARING FLOOR TRUSSES TOP OF 6" SLAB FLOOR ELEVATION = 120 TOP OF 6" CONCRETE SLAB FLOOR ELEVATION = 120 TOP OF 6" CONCRETE SLAB FLOOR ELEVAION = 120 8" PROJECT INFORMATION EXISTING FOOTING AND SLAB FLOOR CONCRETE FOOTING AND 8 INCH STEM WALL TO EXTEND 8 INCHES ABOVE SLAB MICROGREEN SECTION D POLYMERS SECTION A SECTION B SCALE: 1/4 IN = 1 FT SCALE: 1/4 IN = 1 FT SCALE: 1/4 IN = 1 FT 7220 201ST STREET NE ARLINGTON, WA 98223 SNOHOMISH COUNTY PARCEL# 00793300002300 00793300002400 PROJECT NO.: X ____________ DRAWN BY: DS ____________ CHECKED BY: TG ____________ 3:12 ROOF PITCH PROVIDE 8 INCH GAP REVISIONS: 8" TO WALL FOR EXISTING 12 INCH HEEL HEIGHT CONDUIT AT WALL 4/10/2014 AT TRUSS BEARING 2X12 HF#2 RAFTERS AT 24" OC WITH 1/4 IN TO 1 FT SLOPE SOFFIT INTEGRATED 6 3/4 X 24 24F GLB INTO TRUSS DESIGN EXISTING ROOF 33'-0" SUPPORT BEAM 15'-0" 15'-0" 30'-0" ISSUED: STORAGE DECK ABOVE OFFICES (LL=125) (2) 2X12 HF#2 AT 16" OC NEW CMU WALL 19'-0" 19'-0" EXISTING COLUMN 14'-8" 14'-8" EXISTING 6 INCH TILT UP WALL 10'-0" CMU WALL TOP OF 6" CONCRETE SLAB FLOOR ELEVATION = 120 8" SHEET NUMBER / TITLE CONCRETE FOOTING AND 8 INCH STEM WALL TO EXTEND 8 INCHES ABOVE SLAB SECTION F SECTION E SCALE 1/4 IN = 1 FT FOR ADDITIONAL FRAMING AND SCALE: 1/4 IN = 1 FT STRUCTURAL INFORMATION REFER B-1 TO STRUCTURAL (S) PAGES 201ST STREET NE 348.25' FLOOR ELEV 120 S87° 59' 12"E Coast Construction Group 328 N Olympic Ave " 0 '- Arlington, WA 98223 0 4 p. 360-474-0600 BOTTOM OF RAMP 27'-0" AND DRAIN ELEV = 116 f. 360-474-1095 SLOPE CONCRETE AS www.CoastCCG.com REQUIRED FOR DRAINAGE TO OIL/WATER SEPARATOR DRAIN 3 X 6 X 6 OIL / WATER SEPARATOR VAULT ADA VORTCLAREX VCL30 INSTALL PER MANUFACTURER SPECS 10 X 20 X 3 INFILTRATION TRENCH 9"E TOP OF INFILTRATION TRENCH ELEV 115.8 5.' 0' 5 BOTTOM OF TRENCH ELEV 112.8 29 ° 3 9"W N0 5.' 0' 5 29 ° 3 S0 POLYMERS MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 INFILTRATION TRENCH SOIL: FINE TO LOAMY SAND 75 SF OF INFILTRATION PER 100 SF PROJECT INFORMATION MICROGREEN SITE PLAN LOADING DOCK RAMP AREA = 2128 SF POLYMERS SCALE: 1 IN = 30 FT TRENCH AREA REQUIRED = 2128/1000 X 75 = 159.6 SF 7220 201ST STREET NE PROPOSED INFILTRATION TRENCH TO BE 200 SF ARLINGTON, WA 98223 PROPOSED TRENCH 10' X 20' X 3' 348.25' SNOHOMISH COUNTY N87° 59' 12"W PARCEL# 00793300002300 00793300002400 ELEVATIONS PROJECT NO.: TOP OF SHIPPING AREA FLOOR 120.0 X ____________ BOTTOM OF LOADING RAMP 116.0 BOTTOM OF SEPARATOR VAULT INSIDE 110.0 DRAWN BY: TOP OF LID SEPARATOR VAULT 116.5 DS ____________ BOTTOM OF INFILTRATION TRENCH 112.8 CHECKED BY: TOP OF INFILTRATION TRENCH 115.8 TG ____________ REVISIONS: TOP OF STEM WALL BEYOND DOORWAY 4/10/2014 CMU WALL 10'-0" TOP OF TRENCH ELEV 115.8 8" TOP OF SLAB FLOOR 1 FT CLEAN WASHED DRAIN ROCK 1'-0" ELEVATION = 120' THICKEN SLAB TO 8 INCHES AT EDGE WITH EMBEDDED ANGLE IRON CONTINUOUS FILTER 10" (2) 4 INCH PVC PERFORATED DRAIN PIPE FABRIC WITH MIN 4' LAP EACH DIRECTION 2'-0" 2 FT CLEAN WASHED ROCK BLUE GIANT EQUIPMENT BOTTOM OF TRENCH ELEV 112.8 DOCK LEVELER HU7008-30 2'-0" INSTALL PER MANUFACTURERS INFILTRATION TRENCH SECTION SPECIFICATIONS TOP OF RAMP AT WALL ELEVATION = 116' ISSUED: 8'-0" SLOPE TO GRADE APPROXIMATELY 2'-0" 44 INCHES UP IN 56 FEET LEVEL OUT 2 FT THEN SLOPE UP 6 INCHES TO VAULT TOP TOP OF SEPARATOR VAULT ACCESS GRATES ELEV 116.5 TOP OF OUTFALL ELEV 115.0 TOP OF INFILTRATION TRENCH ELEV 115.8 1'-6" TOP OF INLET DRAIN ELEV 115.0 INFILTRATION TRENCH SEPARATOR VAULT BOTTOM OF INFILTRATION TRENCH ELEV 112.8 SHEET NUMBER / TITLE BOTTOM OF SEPARATOR VAULT INSIDE ELEV 110 B-2 SECTION C SCALE: 1/2 IN = 1 FT LOADING RAMP AND STORM WATER MEANS OF EGRESS Lower Offices including existing and new: The occupancy load for the lower floor offices is 3348 square feet / 100 = 34 The required egress width of passageways and doors serving this area is 34 x 0.2 = 6.8" The passageways and doors providing egress for this area exceed the required width Coast Construction Group Upper Offices including existing and new: 328 N Olympic Ave the occupancy load for the upper floor offices is 3554 square feet / 100 = 36 Arlington, WA 98223 The required egress width of stairs serving this are is 36 x 0.3 = 10.8" p. 360-474-0600 The required egress width of doors serving this area is 36 x 0.2 = 7.2" The passageways, doors and stairs providing egress for this area exceed the required width f. 360-474-1095 www.CoastCCG.com New Shipping Area: The occupancy load for the new shipping area is 4948 square feet / 100 = 50 The required egress width of passageways and doors serving this area is 50 x 0.2 = 10" The passageways and doors providing egress for this area exceed the required width 1005.3.1 Stairways. The capacity, in inches (mm), of means of egress stairways shall be calculated by multiplying the occupant load served by such stairway by a means of egress capacity factor of 0.3 inch (7.6 mm) per occupant. Where stairways serve more than one story, only the occupant load of each story considered individually shall be used in calculating the required capacity of the stairways serving that story. 1005.3.2 Other egress components. The capacity, in inches (mm), of means of egress components other than stairways shall be calculated by multiplying the occupant load served by such component by a means of egress capacity factor of 0.2 inch (5.1 mm) per occupant. 1005.4 Continuity. The capacity of the means of egress required from any story of a building shall not be reduced along the path of egress travel until arrival at the public way. 1005.5. Distribution of egress capacity. Where more than one exit, or access to more than one exit, is required, the means of egress shall be configured such that the loss of any one exit, or access to one exit, shall not reduce the available capacity to less than 50 percent of the required capacity. 1006.2 Illumination level. The means of egress illumination level shall not be less than 1 footcandle (11 lux) at the walking surface. POLYMERS Exception: For auditoriums, theaters, concert or opera halls and similar assembly occupancies, the illumination at the walking MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 surface is permitted to be reduced during performances to not less than 0.2 footcandle (2.15 lux), provided that the required illumination is automatically restored upon activation of a premises’ fire alarm system where such system is provided. 1006.3 Emergency power for illumination. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate all of the following areas: 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or more means of egress. 2. Corridors, interior exit stairways and ramps and exit passageways in buildings required to have two or more exits. 3. Exterior egress components at other than their levels of exit discharge until exit discharge is accomplished for buildings required PROJECT INFORMATION to have two or more exits. 4. Interior exit discharge elements, as permitted in Section 1027.1, in buildings required to have two or more exits. MICROGREEN 5. Exterior landings as required by Section 1008.1.6 for exit discharge doorways in buildings required to have two or more exits. POLYMERS The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702. 7220 201ST STREET NE 1006.3.1 Illumination level under emergency power. Emergency lighting facilities shall be arranged to provide initial illumination that ARLINGTON, WA 98223 is at least an average of 1 footcandle (11 lux) and a minimum at any point of 0.1 footcandle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 footcandle (6 lux) average and a minimum at any point of SNOHOMISH COUNTY 0.06 footcandle (0.6 lux) at the end of the emergency lighting time duration. A maximum-to-minimum illumination uniformity ratio of PARCEL# 40 to 1 shall not be exceeded. 00793300002300 1007.3 Stairways. In order to be considered part of an accessible means of egress, a stairway between stories shall have a clear 00793300002400 width of 48 inches (1219 mm) minimum between handrails and shall either incorporate an area of refuge within an enlarged floor- level landing or shall be accessed from either an area of refuge complying with Section 1007.6 or a horizontal exit. Exit access PROJECT NO.: stairways that connect levels in the same story are not permitted as part of an accessible means of egress. X ____________ DEMOLITION GENERAL NOTES DRAWN BY: DS ____________ 1. DEMOLITION CONTRACTOR RESPONSIBLE FOR VERIFICATION OF ALL MATERIALS AND CONSTRUCTION OF ALL FLOOR, WALL, CEILING, AND ROOF ASSEMBLIES. CHECKED BY: TG 2. A SITE SURVEY HAS BEEN PERFORMED REGARDING EXISTING STRUCTURAL COMPONENTS. THE SITE ____________ SURVEY DETERMINED THAT WALLS DESIGNATED TO BE REMOVED ARE NON STRUCTURAL (NON BEARING AND NON SHEARWALL). REVISIONS: 4/10/2014 3. EXISTING CONSTRUCTION THAT IS TO REMAIN SHALL BE PROTECTED FROM DAMAGE AS REQUIRED DURING DEMOLITION OPERATIONS. ANY DAMAGE CAUSED BY THE DEMOLITION SHALL BE REPAIRED AT THE COST OF THE DEMOLITION CONTRACTOR. 4. DEMOLITION CONTRACTOR IS RESPONSIBLE TO MAINTAIN THE CONSTRUCTION FIRE ASSEMBLY RATING FOR ALL EXISTING RATED WALL ASSEMBLIES, ROOF ASSEMBLIES AND/OR SHAFTS. 5. EXISTING UTILITIES TO REMAIN IN SERVICE AND PROTECT THEM DURING SELECTIVE DEMOLITION. 6. CONDUCT DEMOLITION OPERATIONS AND REMOVE DEBRIS TO ENSURE MINIMAL INTERFERENCE WITH ROADS, STREETS, WALKS, AND OTHER ADJACENT OCCUPIED AND USED FACILITIES. ISSUED: 7. PROVIDE TEMPORARY WEATHER PROTECTION, AS REQUIRED, DURING SELECTIVE DEMOLITION AND CONSTRUCTION PROCESS TO ENSURE THAT NO WATER DAMAGE OCCURS TO STRUCTURE, EQUIPMENT, EXTERIOR, OR INTERIOR AREAS. 8. ANY EXISTING FINISHED SURFACES TO REMAIN THAT ARE AFFECTED BY SELECTIVE DEMOLITION SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES UNLESS CONCEALED BY NEW CONSTRUCTION. 9. ALL EXISTING CABINETRY, COUNTERTOPS, SHELVES, ETC. IN AREAS OF DEMOLITION SHALL BE REMOVED, INCLUDING THAT NOT SHOWN SPECIFICALLY SHOWN ON DRAWINGS. 10. CUT AND PATCH FLOOR AS REQUIRED FOR ALL NEW PLUMBING. CAP ABANDONED MECHANICAL BELOW PATCH OF FLOOR SLAB. SHEET NUMBER / TITLE 11. VERIFY ALL MODIFICATIONS OF PLUMBING WITH PLUMBING DRAWINGS. 12. THOROUGHLY CLEAN BUILDING UPON COMPLETION OF SELECTIVE DEMOLITION. C-1 13. TOTAL SCOPE OF DEMOLITION MAY NOT BE COVERED ON THIS SHEET, REVIEW ALL SHEETS IN THE GENERAL NOTES / ENERGY CODE CONSTRUCTION DOCUMENTS TO DETERMINE TOTAL SCOPE OF DEMOLITION. ACCESSIBILITY ACCESSIBLE ROUTES 302.1 General. Floor surfaces shall be stable, firm, and 402.2 Components. Accessible routes shall consist of slip resistant, and shall comply with Section 302. one or more of the following components: Walking surfaces Coast Construction Group Changes in level in floor surfaces shall comply with with a slope not steeper than 1 :20, doors and 328 N Olympic Ave Section 303. doorways, ramps, curb ramps excluding the flared sides, elevators, and platform lifts. All components of an Arlington, WA 98223 302.2 Carpet. Carpet or carpet tile shall be securely accessible route shall comply with the applicable portions p. 360-474-0600 attached and shall have a firm cushion, pad, or backing of this standard. f. 360-474-1095 or no cushion or pad. Carpet or carpet tile shall have a www.CoastCCG.com level loop, textured loop, level cut pile, or level cut/uncut 403.5 Clear Width. The clear width of an accessible pile texture. The pile shall be 1/2 inch (13 mm) maximum route shall be 36 inches (915 mm) minimum. in height. Exposed edges of carpet shall be fastened to the floor and shall have trim along the entire length of 404.2.2 Clear Width. Doorways shall have a clear the exposed edge. Carpet edge trim shall comply with opening width of 32 inches (815 mm) minimum. Section 303. Clear opening width of doorways with swinging doors shall be measured between the face of door and 302.3 Openings. Openings in floor surfaces shall be of stop, with the door open 90 degrees. Openings more a size that does not permit the passage of a 1/2 inch (13 than 24 inches (610 mm) in depth at doors and doorways mm) diameter sphere, except as allowed in Sections without doors shall provide a clear opening 407.4.3, 408.4.3, 409.4.3, 410.4, and 805.10. Elongated width of 36 inches (915 mm) minimum. There shall openings shall be placed so that the long dimension be no projections into the clear opening width lower is perpendicular to the predominant direction of than 34 inches (865 mm) above the floor. Projections travel. into the clear opening width between 34 inches (865 mm) and 80 inches (2030 mm) above the floor shall 303.1 General. Changes in level in floor surfaces shall not exceed 4 inches (100 mm). comply with Section 303. EXCEPTIONS: 303.2 Vertical. Changes in level of 1/4 inch (6.4 mm) 1. Door closers and door stops shall be permitted maximum in height shall be permitted to be vertical. to be 78 inches (1980 mm) minimum 303.3 Beveled. Changes in level greater than 1/4 inch above the floor. (6.4 mm) in height and not more than 1/2 inch (13 mm) 2. In alterations, a projection of 5/s inch (16 maximum in height shall be beveled with a slope not mm) maximum into the required clear opening POLYMERS steeper than 1 :2. width shall be permitted for the latch side MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 303.4 Ramps. Changes in level greater than 1/2 inch (13 stop. mm) in height shall be ramped and shall comply with Section 405 or 406. 404.2.6 Door Hardware. Handles, pulls, latches, locks, and other operable parts on accessible doors 304.2 Floor Surface. Floor surfaces of a turning space shall have a shape that is easy to grasp with one shall comply with Section 302. Changes in level are not hand and does not require tight grasping, pinching, permitted within the turning space. or twisting of the wrist to operate. Operable parts of EXCEPTION: Slopes not steeper than 1 :48 shall be such hardware shall be 34 inches (865 mm) minimum permitted. and 48 inches (1220 mm) maximum above the 304.3 Size. Turning spaces shall comply with Section floor. Where sliding doors are in the fully open position, PROJECT INFORMATION 304.3.1 or 304.3.2. operating hardware shall be exposed and usable from both sides. MICROGREEN 304.3.1 Circular Space. The turning space shall EXCEPTION: Locks used only for security purposes be a circular space with a 60-inch (1525 mm) minimum and not used for normal operation shall not POLYMERS diameter. The turning space shall be permitted be required to comply with Section 404.2.6. to include knee and toe clearance complying 7220 201ST STREET NE with Section 306. ARLINGTON, WA 98223 304.3.2 T-Shaped Space. The turning space shall be a T-shaped space within a 60-inch (1525 mm) SNOHOMISH COUNTY minimum square, with arms and base 36 inches GENERAL SITE AND BUILDING ELEMENTS PARCEL# (915 mm) minimum in width. Each arm of the T 00793300002300 shall be clear of obstructions 12 inches (305 mm) 502.2 Vehicle Space Size. Car parking spaces shall be 00793300002400 minimum in each direction, and the base shall be 96 inches (2440 mm) minimum in width. Van parking clear of obstructions 24 inches (610 mm) minimum. spaces shall be 132 inches (3350 mm) minimum in The turning space shall be permitted to width. PROJECT NO.: include knee and toe clearance complying with EXCEPTION: Van parking spaces shall be permitted X Section 306 only at the end of either the base or to be 96 inches (2440 mm) minimum in width where ____________ one arm. the adjacent access aisle is 96 inches (2440 mm) minimum in width. DRAWN BY: 305.2 Floor Surfaces. Floor surfaces of a clear floor DS space shall comply with Section 302. Changes in level 502.3 Vehicle Space Marking. Car and van parking ____________ are not permitted within the clear floor space. spaces shall be marked to define the width. Where parking spaces are marked with lines, the width measurements CHECKED BY: 306.2.1 General. Space beneath an element of parking spaces and adjacent access TG between the floor and 9 inches (230 mm) above aisles shall be made from the centerline of the markings. ____________ the floor shall be considered toe clearance and shall comply with Section 306.2. 502.4.1 Location. Access aisles shall adjoin an accessible route. Two parking spaces shall be permitted REVISIONS: 306.3.1 General. Space beneath an element to share a common access aisle. Access 4/10/2014 between 9 inches (230 mm) and 27 inches (685 aisles shall not overlap with the vehicular way. Parking mm) above the floor shall be considered knee spaces shall be permitted to have access aisles clearance and shall comply with Section 306.3. placed on either side of the car or van parking space. Van parking spaces that are angled shall have access aisles located on the passenger side of the parking space. 502.4.2 Width. Access aisles serving car and van parking spaces shall be 60 inches (1525 mm) minimum in width. 502.4.3 Length. Access aisles shall extend the full length of the parking spaces they serve. ISSUED: SHEET NUMBER / TITLE C-2 ACCESSIBLE NOTES AND DETAILS Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com POLYMERS MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 OVERVIEW SCALE: NTS PROJECT INFORMATION MICROGREEN POLYMERS 7220 201ST STREET NE ARLINGTON, WA 98223 SNOHOMISH COUNTY PARCEL# 00793300002300 00793300002400 PROJECT NO.: X ____________ DRAWN BY: DS ____________ CHECKED BY: TG ____________ REVISIONS: 4/10/2014 WEST ELEVATION SCALE: 1 IN = 10 FT ISSUED: SHEET NUMBER / TITLE SOUTH ELEVATION SCALE: 1 IN = 10 FT E-1 EXISTING BUILDING ELEVATIONS 25'-0" 250'-0" 24'-11" Coast Construction Group 328 N Olympic Ave 5040FX Arlington, WA 98223 5'-8 1/2" 18'-0" EXISTING ROLLUP p. 360-474-0600 5'-0" 7'-6" f. 360-474-1095 www.CoastCCG.com 6'-0" 6040FX 15'-6" 6" 7'-3" 6'-0" 6040FX 36'-7" 4'-0" 49'-0" 6'-0" 6040FX 6" 6'-0" 6040FX B UP 5'-0" C 6'-0" 5040FX EXISTING AND DEMOLITION 6040FX 11'-4" A EXISITNG WALL TO BE REMOVED 2'-8" 2'-2" B EXISTING CABINETRY AND / OR PLUMBING TO BE REMOVED POLYMERS 12'-0" 4040FX C REMOVE WALL SECTION FOR NEW OPENING MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 9'-6 1/2" D REMOVE BOTTOM STEPS AND LANDING FOR NEW BOTTOM STAIR SECTION 4'-6 1/2" 14'-9" 4040FX 110'-0" 14'-0" 7'-2" 5'-1 1/2" 9'-4" EXISTING ROLLUP UPD 4040FX 4'-2" C 1'-9" 42'-0" 4'-9" 7'-6 1/2" 6'-0" 6040FX PROJECT INFORMATION 19'-3" MEN 4'-9" MICROGREEN ADA POLYMERS 6'-0" 6040FX EXISITING PRINT ROOM 7220 201ST STREET NE 2'-4" 4'-9" 26'-8" ARLINGTON, WA 98223 ADA 19'-9 1/2" 16'-3" SNOHOMISH COUNTY 6'-0" 11'-4 1/2" 6040FX WOMEN 38'-8" PARCEL# 11'-1 1/2" 00793300002300 3'-5" 00793300002400 6'-0" 6040FX A 9'-6" PROJECT NO.: A EXISITNG 11'-3" X PRINT 9'-2" ____________ 7'-0" A EXISTING ROLLUP STORAGE 100'-6" B DRAWN BY: 5040FX 5040FX 5040FX 5040FX 5040FX 40'-9" 75'-0" DS 12'-0" 50'-0" ____________ 49'-8" X 16'-0" EXISTING SHED BUILDING TO BE REMOVED CHECKED BY: 15'-11" EXISTING LOWER FLOOR TG 25'-1" ____________ AND DEMOLITION PLAN SCALE: 1 IN = 10 FT 30'-0" REVISIONS: 4/10/2014 EXISTING TRUCK RAMP TO REMAIN AT THIS 10'-0" LOCATION WITH PARTIAL DEMOLITION AND REBUILD 10'-0" EXISTING COLUMN ISSUED: SHEET NUMBER / TITLE E-2 EXISTING LOWER FLOOR PLAN 25'-0" 250'-0" Coast Construction Group 328 N Olympic Ave 5040FX 5040FX Arlington, WA 98223 5'-0" p. 360-474-0600 f. 360-474-1095 11'-0" www.CoastCCG.com 6'-0" 6040FX 6" 9'-10 1/2" 14'-4 1/2" 6'-0" 6040FX 4'-0" 16'-4" DN 19'-0 1/2" 6'-0" 6040FX 10'-2" 6040FX 6" 6'-0" 6040FX 5'-0" 17'-8 1/2" 6'-0" 6040FX 10'-9" EXISTING AND DEMOLITION DN A EXISITNG WALL TO BE REMOVED B EXISTING CABINETRY AND / OR PLUMBING TO BE REMOVED POLYMERS MICROGREEN 7220 201ST STREET NE ARLINGTON, WA 98223 C REMOVE WALL SECTION FOR NEW OPENING 9'-6" 4'-0" D REMOVE BOTTOM STEPS AND LANDING FOR NEW BOTTOM STAIR SECTION 110'-0" 14'-0" OPEN TO BELOW D 6'-6" 6'-0" 6040FX 10'-4" EXISTING RAILING PROJECT INFORMATION 6'-6" 4'-9" MICROGREEN 10'-0" POLYMERS 6'-0" 6040FX 10'-4" UP 9'-6" 7220 201ST STREET NE 11'-5" 4'-9" 5 STEPS UP TO ARLINGTON, WA 98223 EXISTING STORAGE MEZZANINE SNOHOMISH COUNTY 6'-0" 10'-4" 6040FX EGRESS 4'-2" PARCEL# B A A 00793300002300 3'-5" 00793300002400 EXISTING STAIRS 48" WIDE 6'-0" 6040FX 16'-4" EGRESS ROUTE PROJECT NO.: 14'-4" X EXISTING CONFERENCE ROOM ____________ 7'-0" DRAWN BY: 5040FX 5040FX DS ____________ EXISTING UPPER FLOOR AND DEMOLITION PLAN CHECKED BY: SCALE: 1 IN = 10 FT TG ____________ REVISIONS: 4/10/2014 ISSUED: SHEET NUMBER / TITLE E-3 EXISTING UPPER FLOOR PLAN FIRE SPRINKLER PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 Phone (360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY THREE (3) SETS OF COMPLETE AND SCALED PLANS, THREE (3) SETS OF HYDRALIC CALCULATIONS, THREE (3) SETS OF EQUIPMENT SPECIFICATIONS FOR EACH FIRE SPRINKLER PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS (POINT TO POINT WIRING), AND ALL OTHER INFORMATION ON ALL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION. Type of Permit: New Fire Sprinkler Fire Sprinkler Add/Alt Underground Fire Line Project Address: 19405 68th Drive NE Parcel ID# 007033000023 00 Project Valuation: $2,000.00 Number of Heads: 14 Building Area (Sq Ft): 32624 Owner: Wayne Williams Address: 12221 63rd Ave NE City: Arlington State: WA ZIP: 98223 Contact Person: Wayne Williams Phone: 425-583-4775 Cell Phone: 425-583-4775 Fax Number: E-mail: shelley@umifireprotection.com Contractor Information Contractor: Unlimited Mechanical, Inc. Phone: 425-583-4775 Address: 19221 63rd Ave NE #2 - Arlington, WA. 98223 License Number: UNLIMMI093M6 Expiration: 05/14/2014 Please Attach Plans and Supporting Documents (PDF Only) Microgreen - TI.pdf STAFF USE ONLY: Permit Number: Accepted Receipt # By: Date Received: Amount Received: By submission of this form, I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington. Permit #: 346 Permit Date: 04/15/14 Permit Type: COMMERCIAL ADDITION Project Name: Microgreen Polymers, Inc Applicant Name: Coast Construction Group Applicant Address: 328 N Olympic Ave Applicant, City, State, Zip: Arlington, WA 98223 Contact: Trevor Gaskin Phone: 360-474-0600 Email: trevor@coastccg.com Scope of Work: Manufacturing / Commercial Addition Valuation: 790000.00 Square Feet: 4948 Number of Stories: 2 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: 10/25/2014 Form Permit Type: Status: EXPIRED Assigned To: Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 282 Plastics & JENSEN BUSINESS 00793300002300 7220 201ST ST NE Synthetic Resins, PARKS LLC Rubber, Ex. Glass Contractors Contractor Primary Contact Phone Address Contractor Type License License # COAST TREVOR 328 N OLYMPIC CONSTRUCTION Labor & CONSTRUCTION 360-474-0600 COASTCG865CG GASKIN AVE CONTRACTOR Industries GROUP COAST TREVOR 328 N OLYMPIC CONSTRUCTION CONSTRUCTION 360-474-0600 UBI 602 626 922 GASKIN AVE CONTRACTOR GROUP B & T Design and Jim 425-557-0779 250 E Sunset Way AIA/PE Engineering Plan Reviews Date Review Type Description Assigned To Review Status COMMERCIAL 04/15/2014 Ok to issue with review comments z.Christopher Young ADDITION COMMERCIAL 04/15/2014 Marc Hayes ADDITION COMMERCIAL 04/15/2014 z.Tom Cooper ADDITION COMMERCIAL 04/15/2014 ADDITION Fees Fee Description Notes Amount Building Permit Table 4-1 $6,047.98 State Surcharge - 1st DU Residential - 1st Unit $4.50 Building Plan Review Table 4-2 $3,931.19 Total $9,983.67 Attached Letters Date Letter Description 04/15/2014 Building Permit Notes Date Note Created By: 02/10/2016 Permit never issued per LU50-11-23REV0 Kristin Foster 04/15/2014 Large plans are in the review room. Amy Rusko Uploaded Files Date File Name 04/15/2014 BLD 346 Application.pdf 04/15/2014 BLD 346 Plans 1.pdf 04/15/2014 BLD 346 Plans 2.pdf SCOPE OF WORK PROJECT INFORMATION Coast Construction Group MICROGREEN POLYMERS 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 7220 201ST STREET NE f. 360-474-1095 PROPOSED WORK INCLUDES: www.CoastCCG.com ARLINGTON, WA 98223 ENCLOSING OPEN AREA WITH NEW WOOD FRAMED WALLS INCLUDING ONE 20 X 14 INSULATED ROLL UP DOOR ADDING INTERIOR WALLS PROJECT LOCATION MAP 201ST STREET NE ADDING WOOD FRAMED LOFT / STORAGE MICROGREEN BUILDING ON SITE FABRICATION OF STEEL STAIRS AND RAILING FOR LOFT ALL CONSTRUCTION TO BE COMPLETED ON EXISTING 6" CONCRETE SLAB FLOOR EXISTING BUILDING 7220 201ST STREET NE ARLINGTON, WA 98223 PROPOSED WORK INCLUDES THIS AREA ONLY MICROGREEN POLYMERS PROJECT INFORMATION MICROGREEN POLYMERS 7220 201ST STREET NE ARLINGTON, WA 98223 74TH AVE NE PARCEL: 00793300002300 00793300002400 GENERAL NOTES CODE INFORMATION PROJECT CONTACTS SHEET INDEX DESIGNER: COAST CONSTRUCTION GROUP PROJECT NO: 1. CONTRACTOR SHALL VERIFY AND COORDINATE ALL DRAWINGS AND REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR ALL CONSTRUCTION FOR THIS PROJECT 328 N OLYMPIC AVE X CLARIFICATION AND RESOLUTION PRIOR TO PERFORMING ANY WORK. DISCREPANCIES AMONG THE DRAWINGS OR BETWEEN THE SHALL COMPLY WITH THE FOLLOWING: ARLINGTON, WA 98223 COVER COVER PAGE DRAWINGS AND THE SITE CONDITIONS DO NOT QUALIFY AS GROUNDS FOR COMPENSATION FROM THE OWNER, PROFESSIONALS FOR O 360-474-0600 A1 ELEVATIONS DRAWN BY: ERRORS IN BUILD-OUT OR INSTALLATION. F 360-474-1095 A2 FLOOR PLAN AND FLOOR FRAMING DS 2012 INTERNATIONAL BUILDING CODE CONTACT: TREVOR GASKIN A3 CROSS SECTIONS 2. DO NOT SCALE THE DRAWING. 2012 INTERNATIONAL MECHANICAL CODE EMAIL: TREVOR@COASTCCG.COM CHECKED BY: 2012 INTERNATIONAL FIRE CODE TG 3. ALL WORK SHALL CONFORM TO THE LATEST ADOPTED ISSUES OF ALL APPLICABLE CODES AND LOCAL REGULATIONS. 2012 INTERNATIONAL FUEL GAS CODE CONTRACTOR: 2012 UNIFORM PLUMBING CODE COAST CONSTRUCTION GROUP 4. ALL NEW WORK SHALL BE IN COMPLIANCE WITH FEDERAL, STATE, AND LOCAL REGULATIONS. NATIONAL ELECTRICAL CODE (NFPA 70) 328 N OLYMPIC AVE 2009 ICC/ANSI A117.1-09 ARLINGTON, WA 98223 REVISIONS 5. ALL DIMENSIONS ARE INSIDE ROOM CLEAR DIMENSIONS, UNLESS NOTED OTHERWISE. 2012 WASHINGTON STATE ENERGY CODE O 360-474-0600 F 360-474-1095 2/17/2014 6. CONTRACTOR SHALL PROVIDE ALL NEEDED BLOCKING FOR ATTACHMENT OF WALL-HUNG ITEMS. CONTACT: TREVOR GASKIN OCCUPANCY TYPE - F1 / B EMAIL: TREVOR@COASTCCG.COM 7. CONTRACTOR SHALL PROVIDE SEISMIC BRACING FOR CEILING SYSTEM & OTHER SUSPENDED FIXTURES AS NECESSARY. CONSTRUCTION TYPE - VB SPRINKLERED - YES TENANT: 8. CONTRACTOR SHALL PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY THE FIRE DEPARTMENT. FIRE ALARMED - YES MICROGREEN POLYMERS 7220 201ST STREET NE 9. EXTERIOR SIGNAGE TO BE PROVIDED BY THE OWNER UNDER SEPARATE CONTRACT. SQUARE FOOTAGE SUMMARY ARLINGTON, WA 98223 O 360-435-7400 10. THIS BUILDING ONLY HAS 120/240 100A WIRE ELECTRICAL SERVICE. EXISTING MANUFACTURING AREA 27,500 F 360-435-0248 EXISTING MAIN FLOOR OFFICE AREA 2,639 CONTACT: TONY LASALATA 11. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH MEDICAL SUPPLIER FOR INFORMATION FOR BIDDING EXISTING UPPER FLOOR OFFICE AREA 2,485 EMAIL: TONY.LASALATA@MICROGREENINC.COM ISSUED: AND INSTALLATION OF ITEMS SUPPLIED IN THE PACKAGE. TOTAL EXISTING FLOOR AREA 32,624 OWNER: 12. DEMO WORK MAY NOT BE SHOWN IN PLANS. CONTRACTOR SHALL COORDINATE WITH OWNER AND RECONCILE WITH PLANS TO JENSEN BUSINESS PARK, LLC DETERMINE SCOPE OF DEMO WORK. 20613 OLD BURN HILL RD ARLINGTON, WA 98223 O 425-356-7082 F 360-652-5161 CONTACT: DEAN JENSEN EMAIL: DAJEX54@MSN.COM SHEET NUMBER / TITLE COVER Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com EXISTING ROOF TO REMAIN UNCHANGED LP T1-11 SIDING NEW 20 X 14 INSULATED ROLL UP DOOR 7220 201ST STREET NE ARLINGTON, WA 98223 MICROGREEN POLYMERS PROJECT INFORMATION MICROGREEN POLYMERS SOUTH ELEVATION 7220 201ST STREET NE SCALE: 1 /4 iN = 1 FT ARLINGTON, WA 98223 PARCEL: 00793300002300 00793300002400 PROJECT NO: X DRAWN BY: DS CHECKED BY: TG REVISIONS 2/17/2014 EXISTING 6" TILT UP CONCRETE WALL ISSUED: LP T1-11 SIDING EAST ELEVATION SCALE: 1/4 IN = 1 FT SHEET NUMBER / TITLE A1 A A3 Coast Construction Group 328 N Olympic Ave 25' 50' Arlington, WA 98223 EXISTING 6" TILT UP 6'-0" CONCRETE WALL p. 360-474-0600 75' f. 360-474-1095 www.CoastCCG.com NEW 2X4 WALL 7'-0" EXISTING 2X4 WOOD 9'-4" TOP PLATE HT FRAMED WALL 7080 ROLLUP DOOR 6X12 DF#2 HEADER NEW 2X4 WALL STEEL STAIRS AND RAILING TO BE 9'-4" TOP PLATE HT FABRICATED ON SITE MAX RISE 7" MAX RUN 11" 6X6 COLUMN 3070 WITH AB AND AC CONNECTORS 4040 FIXED WINDOW 10' EXISTING STEEL COLUMNS TO UPPER ROOF BEAM TO REMAIN UNCHANGED 3070 HALF LITE 10' 7220 201ST STREET NE ARLINGTON, WA 98223 EXISTING STEEL COLUMNS TO UPPER ROOF BEAM TO REMAIN UNCHANGED 3070 MICROGREEN POLYMERS 6X12 DF#2 HEADER 20 X 14 ROLLUP DOOR PROJECT INFORMATION EXISTING STEEL COLUMNS TO UPPER FLOOR PLAN ROOF BEAM TO REMAIN UNCHANGED SCALE: 1/4 IN = 1 FT MICROGREEN POLYMERS 7220 201ST STREET NE 25' 4 1/2" 3' 24' 3 1/2" 20' 2' 6" ARLINGTON, WA 98223 PARCEL: 100' 00793300002300 00793300002400 NEW EXTERIOR WALL FRAMED UNDER EXISTING BEAM TO BE 2X6 STUDS AT 16" OC WITH PT BOTTOM PLATE AND 5/8 X 7 EXPANSION ANCORS AT 48" OC. 1/2" CDX PLYWOOD ON INTERIOR FACE AND LP T1-11 SHEATHING ON EXTERIOR FACE BOTH FACES NAILED WITH 10D AT 6" OC EDGES AND 12" OC FIELD BLOCK ALL PANEL EDGES PROJECT NO: X DRAWN BY: DS 2X12 LEDGER WITH CHECKED BY: 5/8 X 7 EXPANSION BOLTS TG STAGGERED AT 12" OC INTO EXISTING CONCRETE WALL B A3 REVISIONS 2/17/2014 SOLID BLOCKING OVER BEAM DOUBLE2X12 RIM JOIST TYPICAL FLOOR JOISTS TO BE DBL 2X12 HF#2 AT 16" OC DOUBLE JOISTS TO BE JOINED 2X12 HF#2 FLOOR JOISTS AT 16" OC WITH 10D STAGGERED AT 16" OC AT THIS AREA ONLY ISSUED: SHEET NUMBER / TITLE FLOOR FRAMING PLAN SCALE: 1/4 IN = 1 FT A2 Coast Construction Group 328 N Olympic Ave Arlington, WA 98223 p. 360-474-0600 f. 360-474-1095 www.CoastCCG.com EXISTING ROOF TRUSSES TO REMAIN UNCHANGED EXISTING 6" TILT UP CONCRETE WALL EXISTING BEAM SUPPORTING ROOF SOLID BLOCKING OVER BEAM 8' 7 1/2" NEW 2X6 WALL FRAMED UNDER BEAM DBL 2X12 HF#2 AT 16" OC 7220 201ST STREET NE ARLINGTON, WA 98223 7080 ROLUP DOOR 9'-4" MICROGREEN POLYMERS 5 1/8 X 16 1/2 24F GLB PROJECT INFORMATION MICROGREEN POLYMERS SECTION A EXISTING CONCRETE SLAB 7220 201ST STREET NE ARLINGTON, WA 98223 SCALE: 1/4 IN = 1 FT PARCEL: 00793300002300 00793300002400 PROJECT NO: X DRAWN BY: DS EXISTING ROOF TRUSSES CHECKED BY: TG EXISTING BEAM SUPPORTING ROOF CEILING PROVIDED BY EXISTING TRUSSES REVISIONS 2/17/2014 STEEL STAIRS AND RAILING TO BE FABRICATED ON SITE MAX RISE 7" MAX RUN 11" 5/4" SUBFLOOR SHEATHING EXISTING 2X4 WOOD FRAMED WALL ISSUED: 5 1/8 X 16 1/2 24F GLB 6X6 COLUMN WITH AB AND AC CONNECTORS SECTION B SCALE: 1/4 IN = 1 FT SHEET NUMBER / TITLE A3