Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
7220 201st St Ne_BLD1830_2025
INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight® Model 5820XL Addressable Fire Alarm Control System The IntelliKnight System is the easy way to make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 serial/parallel printer interface module (for printing system reports), and 5895XL intelligent power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol • Built in support for 127 SD devices, expandable to 508 SD devices using the SD protocol. • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator Model 5820XL • Central station reporting by point or by zone • 6 amp power supply and maximum • Built-in synchronization for appliances from AMSECO®, charging capacity of 35 amp hours (An Gentex®, Faraday, System Sensor, and Wheelock® additional cabinet enclosure is required for • Flexputâ„¢ I/O circuits batteries in excess of 18 amp hours) • Supports Class B (Style 4) and Class A (Style 6) configuration • Programmable date setting for Daylight for SLC, SBUS, and Flexput circuits Saving Time • 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Installation • Built-in annunciator with 80-character LCD display The 5820XL can be surface or flush • RS-485 bus provides communication to system accessories mounted • Built-in RS-232 and USB interface for programming via PC • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Compatibility • Improvements in SKSS software deliver five times faster The 5820XL signal line circuit (SLC) uploads/downloads supports multiple device types of the same • Two built-in Form C programmable relays rated at 2.5 amps protocol: at 27.4 VDC • SK (System Sensor) • Plex-1 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing •SD single button operation of the reset and silence functions You cannot mix SD and SK SLC devices on a FACP. INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights 5820XL features a 6 amp power supply required to start a new system. The and maximum battery charging built-in keypad and 5860 remote General Alarm (Red): Flashes when in capacity of 35 amp hours. An additional annunciator give on-site access to all alarm; solid when alarm silenced cabinet enclosure (PN RBB) is required programming. You can also program Supervisory (Yellow): Flashes when a for batteries in excess of 18 amp hours. remotely using the 5660 Silent Knight supervisory condition exists; solid when Flexput circuits on 5820XL control can Software Suite, which is Windows®- supervisory silenced be individually programmed to function based software. System Troubles (Yellow): Flashes as notification circuits, auxiliary power when a trouble condition exists; solid outputs, or initiation circuits that Built-In Digital Communicator when trouble silenced support both 2- and 4-wire smoke 5820XL features a built-in UL listed detectors. System Silenced (Yellow): On when an digital communicator for remote The 5820XL system operates on non- alarm, trouble or supervisory condition reporting of system activity and system twisted, unshielded cable when wired has been silenced but not yet cleared programming. The communicator has in compliance with standard wiring the ability to seize two telephone lines System Power (Green): Flashes for AC practices as called out in the National to report alarms and troubles to a failure; solid when power systems are Electric Code 760-51 specifications for monitoring facility. The communicator normal power-limited fire protective signalling supervises two phone lines and will cables. No special wiring is required. activate a trouble signal if a line failure System Application 5820XL provides 13 preset notification is sustained for more than 45 seconds. 5820XL has one built-in signalling line cadence patterns (including ANSI 3.41) Other communication features include: circuit (SLC) which supports multiple and four user programmable selections retry if communication fails, two phone devices dependent on protocol being for fire alarm notification. number capability, download phone used. Three additional loops can be Two programmable general purpose number capability and Touch-Tone or added using the 5815XL SLC Form C relay outputs are provided on rotary dialing. The communicator is expanders to increase overall capacity. 5820XL. compatible with SIA and Ademco Additionally, the IntelliKnight system Contact ID. The format is selectable by The 5820XL SLC loops support features a built-in walk test and auto- account number. multiple device types, including: programming. Its innovative, dead-front • Addressable photoelectric smoke cabinet design allows for flush or detector surface mounting. System maintenance • Addressable ionization smoke is easy to perform. detector User Interface • Addressable heat sensor The 5820XL built-in annunciator with • Addressable duct smoke detector 80 character LCD display and large • Contact module easy-to-use tactile touchpad can be used for system operation, • Relay output module programming and maintenance. It has • Addressable notification module five LEDs for alarm, supervisory, • Addressable beam detector (SK system trouble, system silenced and protocol only) system power. System operations include silencing alarms and troubles, • Addressable multi-criteria smoke Approvals resetting alarms and the display of detector (SK protocol only) NFPA 13, NFPA 15, NFPA 16, alarm troubles and memory. The NFPA 72: Central Station; Remote • Addressable multi modules (SK system's non-volatile event history Signalling; Local Protective Signalling protocol only) buffer stores 1000 events for viewing Systems; Auxiliary Protected Premises from the built-in or remote annunciator. The following advanced sensor Unit; & Water Deluge Releasing System operation can be initiated with capabilities are available with 5820XL: Service. Suitable for automatic, a mechanical firefighter's key or a valid manual, waterflow, sprinkler • Automatic drift compensation 4- to 7-digit operator's code. supervisory (DACT non-coded) • Maintenance alert Programming signalling services. • Built-in sensor test to comply with The IntelliKnight system offers several Other Approvals: UL Listed; NFPA 72 calibration testing options to simplify and speed up CSFM 7170-0559: 135; requirements ® programming. The JumpStart feature MEA429-92-E Vol. VI; FM Approved minimizes programming INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Specifications S-BUS Accessories Miscellaneous Accessories Electrical 5860/R Remote Fire Annunciator 5660 Silent Knight Software Suite Primary AC: Features the same 80 character backlit (SKSS) 120 VRMS at 50/60 Hz, 2.5A or LCD display keypad and firefighter's User-friendly Windows software for keyswitch as the 5820XL. 5860 is gray remote programming of 5820XLs using 240 VRMS at 50/60 Hz, 1.4A and 5860R is red. a PC. Upload and view panel account Total Accessory Load: 6A @ 27.4 VDC, 5815XL Signal Line Circuit Expander information, event history, and detector power-limited The SLC expander is used to add more status. Standby Current: 215 mA addressable devices to the IntelliKnight 5670 Silent Knight Software Suite Alarm Current: 385 mA system. 5820XL supports three (SKSS) Flexput Circuits: 5815XL’s. Each 5815XL can support 99 Powerful end-user facility management Six programmable circuits which can be SK detectors and 99 SK modules or software allows viewing of detector programmed individually as: 127 SD devices. status and event history via modem or Notification circuits: 3A @ 27.4 VDC 5895XL Intelligent Power Module direct connection. per circuit, power-limited Adds 6 amps of power, 6 Flexput I/O Plex-1 circuits and 2 Form C relay circuits to a Dead front cabinet door with clear Auxiliary power circuits: 3A @ 27.4VDC 5820XL system. window to limit access to the FACP. per circuit, power-limited 5496 Intelligent Power Module RBB Initiation Circuits: 100 mA @ 27.4VDC A 6 amp notification power expander Remote battery box accessory cabinet. per circuit, power limited that provides four power-limited notifi- Use if backup batteries are too large to Physical cation appliance circuit outputs. fit into FACP cabinet. Dimensions: Flush Mount Dimensions: 16†W x 10†H x 6†D 5880 LED/IO Module 14.5â€W x 24.75â€H x 3.9â€D Features 40 LED outputs, 8 normally (406 mm W x 254 mm H x 152 mm D) (36.8 W x 62.9 H x 9.8 D cm ) open dry contact inputs, and one piezo SD505-DTS-K output. Remote test switch. Used with Overall Dimensions: 5865-3 and 5865-4 SD505-DUCTR. Provides remote key 16.2â€W x 26.4â€H x 4.2â€D Remote LED Annunciator operated test function and annunciation (40.6 W x 67 H x 11.8 D cm) Features 30 programmable LED (15 of detector alarm. red and 15 yellow) outputs, and a piezo SD and SK Devices Weight: 28 lbs. (12.8 kg) sounder. The 5865-4 adds a silence See the specification sheets listed Color: Red and reset switch to the package. below for a complete listing of the SD Battery Charging Capacity: 7.0-35 AH 5883 Relay Board and SK devices. Features 10 general purpose Form C 53624 SD Devices Data Sheet Battery Size: 18 AH max allowed in relays. Used with 5880 module. 53623 SK Devices Data Sheet control panel cabinet. Larger capacity 5824 Serial/Parallel Printer batteries can be housed in RBB Interface Module accessory cabinet. Provides one parallel and one RS-232 serial port for connecting a printer to Telephone Requirements: the 5820XL. Use to print a real-time log of system events, detector status FCC Part 15 and Part 68 approved reports, and event history. Interfaces Type of Jack: RJ31X (two required) with building control system. This document is not intended to be used for installation purposes. We try to keep our Made in America product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472 PN 350210 Rev H2 Phone: (203) 484-7161, Fax: (203) 484-7118. www.silentknight.com. © 2012 Honeywell International Inc. IntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight INTELLIKNIGHT ACCESSORY Model 5895XL Intelligent Power Module The intelligent way to distribute power throughout your installation. With 6.0 amps of output power, six programmable Flexputâ„¢ I/O circuits, and two Form C relay contacts, the Model 5895XL Intelligent Power Module allows you to greatly enhance the capabilities of an IntelliKnight system, distributing power where needed throughout a facility. 5895XL modules connect via the RS-485 system bus. Up to eight 5895XL modules can be used per IntelliKnight system. Each 5895XL has its own optically isolated RS-485 bus to which other modules, such as 5860 remote annunciators and 5824 printer interface modules, can be connected. You can also connect 5815XL SLC expansion modules, adding flexibility and wiring distance. Each 5895XL supports its own backup batteries and monitors the AC power. Description 5895XL adds 6.0 amps of power, six Flexput I/O circuits, and two Form C relay circuits to an IntelliKnight installation. The 5895XL is optically isolated providing ground loop isolation and transient protection. The 5895XL conditions the RS-485 system bus allowing up to an additional 6,000 feet of wiring. Operation The green LED on the 5895XL board indicates communication with the IntelliKnight FACP. The Flexput circuits can be notification appliance circuits, continuous power, resettable power, door holder power or initiation circuits that can support both 2- and 4-wire smoke detectors. All Flexput circuits and relay outputs are individually mappable from the IntelliKnight 5820XL FACP. Model 5895XL Features • 6.0A output power Approvals • Flexput I/O circuits, 3A each, programmable as notification • NFPA 13, NFPA 15, NFPA 16, NFPA 70, circuits, auxiliary power circuits, or initiation circuits NFPA 72 and NFPA 101 • Supports Class A configuration for SBUS & Flexput circuits • UL 864; CSFM • Ground loop isolation • MEA 429-92-E, Vol. IX • 2 Form C programmable relays rated at 2.5A at 24 VDC • FM approved • Transient protection • OSHPD (CA) OSP-0065-10 • SBUS repeater conditions the RS-485 signal • Up to 6,000 feet wiring distance from 5895XL (same distance as main FACP) • Battery charging capacity 35 Ah • Large cabinet can house two 18 Ah batteries or RBB accessory cabinet can house battery sizes larger than 18 Ah • Room in FACP cabinet to mount two 5815XL SLC expander's • Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor®, and Wheelock® INTELLIKNIGHT ACCESSORY Model 5895XL Intelligent Power Module Engineering Specifications The contractor shall supply a power module compatible with the IntelliKnight Model 5820XL FACP. The power module must have 6.0 amps of output power, Flexput I/O circuits rated 3.0 amps each, and two Form C relay contacts rated at 2.5 amps at 24 VDC. The power module shall connect to the main FACP via an RS-485 system bus (SBUS). The power module shall contain an additional RS-485 bus that is completely compatible with all IntelliKnight add-on modules, including 5815XL SLC expander's, 5860 remote annunciators, 5824 serial/parallel printer interface modules. The power module RS-485 bus shall be optically isolated providing ground loop isolation and transient protection. The unit shall be an SBUS repeater that conditions the signal driving up to 6,000 feet of additional wiring. Electrical Specifications Overall Dimensions: 16-1/8â€W x 26-3/8â€H x 4-1/8â€D Primary AC: (40.6 W x 67 H x 11.8 D cm) 120 VRMS @ 60 Hz, 2.5A 240 VRMS @ 60 Hz, 1.4A Color: Red Total Accessory Load: Environmental 6A @ 24 VDC Operating Temperature: Current: 32ºF – 120ºF (0º – 49ºC Standby: 40 mA Humidity: 10% – 93% Alarm: 160 mA non-condensing Mechanical Specifications Ordering Information Flush or surface mount Dimensions: 5895XL Intelligent Power Module 14-1/2â€W x 24-3/4â€H x 3-7/8â€D Accessories (36.8 W x 62.9 H x 9.8 D cm ) SK-SCK Seismic Compliance Kit This document is not intended to be used for installation purposes. We try to Assembled in America keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to PN 350212 Rev F change without notice. For more information, contact Silent Knight 12 Clintonville © 2014 Honeywell International Inc. Road, Northford, CT 06472 Phone: (203) 484-7161, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com. INTELLIKNIGHT ACCESSORY 5860 Remote Annunciator Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility Now you can operate and program your IntelliKnight system from up to twelve locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel’s built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation. All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter’s key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description • Available in red or light gray Features include an 80-character • Support for simultaneous use of backlit LCD providing easy-to- multiple 5860s understand system messages. The • RS-485 interface to panel annunciator is ergonomically • Operation and appearance is designed with over-sized buttons identical to 5860 built-in for the most frequently used annunciator features, like Reset and Silence. • On-board piezo sounder audibly indicates alarms, troubles, and In addition to status messages supervisories displayed on the LCD, there are • Five status LEDs for alarm, five LEDs for alarm, supervisory, supervisory, trouble, silence and trouble, silence, and AC power AC power conditions status. • Wiring lengths up to 6000 ft. from 5860 The annunciator is available in gray the FACP (depending on wire Environmental gauge and number of devices on Operating Temperature: 32ºF – to match virtually any decor and SBUS) 120ºF (0ºC – 49ºC) red for applications where the annunciator must stand out. The • UL listed, complies with NFPA 72 Humidity: 10% – 93% non- annunciator enclosure can be • CSFM approved condensing surface or flush mounted. A trim Electrical Specifications Compatibility ring kit is available for surface Operating Voltage: 24 VDC The 5860 is compatible with the mounting. Standby Current: 20 mA max following FACP’s: Features Alarm Current: 25 mA • 5820XL Addressable Fire Control • 80-character backlit LCD display Wiring Distance: 6,000 max. from Panel (4 lines with 20 characters on FACP (depending on wire gauge • 5820XL-EVS Fire Control Panel each line) with Emergency Voice System and number of devices on the • Tactile and audible feedback SBUS) • 5808 Addressable Fire Control • Accepts user codes or fire Panel fighter’s key Mechanical Specifications • 5700 Addressable Fire Control • Larger keypad buttons for system Physical 9.1†W x 7.4†H x 1.5†D Panel reset and silence (23.1 W x 18.8 H x 3.8 D cm) • Install up to twelve 5860s per Shipping Weight: 2.8 lbs (1.3 kg) 5820XL/EVS or 5808 system Color • Install up to eight 5860s per 5700 PN 350224 Rev G 5860R: Red system © 2014 Honeywell International Inc 5860: Gray INTELLIKNIGHT ACCESSORY 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to 12 remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter’s key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Listings Ordering Information NFPA 72; UL Listed; 5860R Remote Annunicator four line LCD CSFM 7170-0559: 135; annunciator with 20 characters per line. MEA 429-92-E Vol. IX; Red FM Approved 5860 Remote Annunciator four line LCD annunciator with 20 characters per line. Gray Accessories 5860TR Red Trim Ring for surface mounting 5860TG Gray Trim Ring for surface mounting This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com Assembled in America INTELLIKNIGHT ACCESSORY Analog/Addressable Devices with Hochiki (SD) Protocol SD Devices SD505-AIS An ionization smoke detector that SD devices are intelligent analog/addressable devices for use has a sampling chamber and with the following IntelliKnight addressable fire alarm control reference chamber for high stability panels (FACPs): 5820XL, 5808 and 5700. SD detectors, and for a variety of applications modules, and accessories communicate to the FACP over the where early warning of trouble from signaling line circuit loop (SLC loop) using a two wire connection. super-heated or flaming Shielded or twisted wire is not required. Up to 127 addressable combustibles is desired. Presence of SD devices can communicate with the FACP on a single SLC visible smoke or invisible gases loop. Any combination of addressable SD devices and SD greatly influences the current flow in SD505-AIS modules can be used on a single SLC loop. the sampling chamber, changing the (Base not included) The assortment of SD detectors, modules, and accessories that voltage ratio between the chambers. are compatible with IntelliKnight addressable FACPs are The difference is amplified inside the detector. When described below. For detailed information on SD devices, see reaching a critical level, the detector triggers an alarm. the device specification sheet. Detectors SD505-DUCT SD505-APS A addressable duct smoke detector that detects smoke A photoelectric smoke detector. SD505-APS and products of combustion present in air moving has an LED light source and silicon photo through an HVAC duct. This duct detector is housed in a diode receiving element. The detector heavy duty metal housing with a preinstalled SD505-APS features automatic drift compensation for photoelectric smoke detector. SD505-DUCT has an air contamination and a simple detector velocity rating from 300 feet per minute to 4,000 feet per calibration test procedure that can be run at minute. Order SD505-T2, SD505-T5, or SD505-T10 air the FACP or remotely using 5650/5651 sampling tubes separately. Silent Knight Software Suite. SD505-APS (Base not included) SD505-DUCTR SD505-AHS A duct smoke detector that detects smoke and products A fixed temperature heat detector that uses of combustion present in air moving an externally mounted thermistor with a through an HVAC duct. The SD505- specially designed cover that protects the DUCTR provides a fully thermistor while allowing maximum air flow. programmable Form C contact. This SD-505-AHS offers a programmable trip duct detector is housed in a heavy point temperature from 135ºF – 150ºF duty metal housing with a (57ºC – 65ºC). This detector is well suited preinstalled SD505-APS for environments where smoke detectors photoelectric smoke detector and SD505-AHS relay module. When smoke is cannot be used because of the presence of (Base not included) steam or cooking fumes, such as in a detected in a duct, the detector kitchen. communicates the condition to the SD505-DUCTR FACP. The built-in relay module then turns off fans, blowers, and other devices. SD505- DUCTR has an air velocity rating from 300 feet per minute to 4,000 feet per minute Order SD505-T2, SD505-T5, or SD505-T10 air sampling tubes separately. Optional SD505-DTS-2 remote test switch available. INTELLIKNIGHT ACCESSORY SD Devices Modules SD500-LED An LED driver module that connects to the SLC loop and is SD500-AIM capable of driving 80 LEDs. IntelliKnight FACPs support up to A dry contact input module that acts as an 40 SD500-LEDs per SLC loop. interface to contact devices, such as waterflow switches and pull stations. The SD500-AIM supports Class B supervised Accessories wiring.This module monitors for alarm SD500-PS/SD500-PSDA contact closures and open circuit wiring fault conditions. Mounts in a 4†square box. The SD500-PS is a single action pull station SD500-AIM requiring only one motion to activate the SD500-MIM station. The SD500-PSDA is a dual action A compact and light weight monitor module that acts as an pull station requiring two motions to activate interface to contact devices, such as waterflow switches and the station. Both pull stations feature a pull stations. The SD500-MIM supports Class B supervised rugged metal construction and mount in a wiring. This module mounts in a single gang box. single gang box. SD500-PS SD500-ARM SD505-DTS-2 A relay module that provides one relay with two Form C Aremote test switch for use with the contacts rated at 2.0A @ 30 VDC or 0.6A @ 120 VAC. The SD505-DUCTR that provides remote key operated test function SD500-ARM can control a wide variety of normally open or and annunciation of detector alarm. normally closed applications, including elevator recall, door SD505-6SB closing, fan operation, and auxiliary notification. A6†mounting base adds an audible output function to SD505- SD500-ANM APS, SD505-AIS, and SD505-AHS. The SD505-6SB can be A notification module that lets you add notification circuits used as a single station, multi-station, or as a system sounder. wherever they are needed on an FACP SLC loop. The SD505-6RB SD500-ANM provides supervised monitoring of wiring to load devices such as bells, horns, and strobes. You can supply A 6†mounting base with one Form C relay contact. The SD505- power to this module near the signaling appliance to reduce 6RB lets you control a wide variety of normally open and wire gauge requirements or supply power from a main power normally closed applications, including elevator recall, door supply and control it separately by the individual notification closing, fan operation, and auxiliary notification. Because this modules. The SD500-ANM supports Class B and Class A relay is addressable, the relay device can be located at any point on the SLC loop. wiring and all 16 notification patterns available on the FACP. SD505-6IB SD500-SDM A6†mounting base with a built-in isolator Atwo-wire interface module that allows an FACP to interface for SD505-APS, SD505-AIS, and SD505- with and monitor two-wire conventional devices. This means AHS detectors. When the SD505-6IB is you can retrofit an existing building and use existing connected to the SLC loop, a short, open, conventional devices, including two-wire smoke detectors and or ground fault occurring on the SLC loop devices with dry contacts, such as pull stations and heat is detected as a trouble but all SLC detectors. The SD500-SDM transmits the status condition devices continue to operate. SD505-6IB (normal, open, or alarm) of one full zone of two-wire devices fits under SD505-6AB detector base to the FACP. The SD500-SDM supports Class B and Class A (included). wiring SD505-6IB Isolator Base SD505-6AB SD500-LIM A6†mounting base is for use with SD505-APS, SD505-AIS, Aline isolator module that isolates a and SD505-AHS. short circuit wiring fault on an SLC loop. When a short occurs on the SLC SD505-4AB loop, it is detected as a trouble but all A4†mounting base is for use with SD505-APS, SD505-AIS, of the SLC devices protected by a and SD505-AHS. SD500-LIM will continue to operate. SD500-LIM This document is not intended to be used for installation purposes. We try to keep MADE IN AMERICA our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change PN 53624 Rev B2 without notice. For more information, contact Silent Knight 12 Clintonville Road, © 2010 Honeywell International Inc. Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com INTELLIKNIGHT ACCESSORY SD500-AIM & SD500-MIM Addressable Input Modules IntelliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description • DIP switch programmable for fast installation The SD500-AIM and SD500-MIM are addressable input modules for use with • Up to 2500 ft wiring distance from either input module to contact the Intelliknight fire alarm control panels (FACPs). The SD500-AIM • Use up to 14 gauge wire addressable input module mounts to a • UL listed 4"-square box. The SD500-MIM mini input module fits inside a single gang Electrical Specifications box. Both input modules are designed Standby Current: 0.55 mA to be used with pull stations, water flow Alarm Current: 23 mA max for one switches, and other applications device; 46 mA max for two devices; requiring dry contact alarm initiation 0.55 mA for each additional device devices. Line Resistance: 50ž max These modules are supervised, single input contact monitors. Using an EOL Mechanical Specifications resistor, they monitor for alarm contact SD500-AIM Physical Description closures and for open circuit wiring Dimensions: fault conditions. If a fault occurs in the 4.9" W x 4.9" H x 1" D wiring, the module alerts the FACP. (12.4 W x 12.4 H x 2.5 D cm) Each addressable input module is Weight: 3.6 oz (120.1 g) programmed with a unique signal line Color: Ivory cover plate circuit (SLC) loop address. SD500-MIM Physical Description Approvals Features Dimensions: NFPA 71 & NFPA 72 • Single contact monitor 1.5" W x 2.5" H x 0.7" D UL 864 (3.8 W x 6.4 H x 1.8 D cm) • SD500-AIM supports Class A (Style CSFM 7300-0559: 132 Weight: 1.6 oz (45.4 g) D) or Class B (Style B) contact MEA 429-92-E Vol. IX monitor wiring Environmental FM Approved for use with the 5820XL • SD500-MIM support for Class B Operating Temperature: (Style B) contact monitor wiring 32ºF – 120ºF (0ºC – 49ºC) • Attractive ivory cover plate with the SD500-AIM Humidity: 10% – 93% non-condensing • Small and lightweight size allows for flexible mounting options with the SD500-MIM INTELLIKNIGHT ACCESSORY SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate Compatible FACPs Ordering Information 5820XL SD500-AIM Input Module 5820XL-EVS Addressable input module with ivory cover plate. 5808 SD500-MIM Input Module 5700 Addressable mini input module. This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350231 Rev. F subject to change without notice. For more information, contact Silent Knight © 2013 Honeywell International Inc 12 Clintonville Road, Northford, CT 06472-1610.Phone: (800) 328-0103 Fax: (763) 493-6475 For Technical Support, Please call 800-446-6444. .www.silentknight.com INTELLIKNIGHT ACCESSORY SD500-PS and SD500-PSDA Addressable Pull-Station IntelliKnight's addressable pull stations combine fast response with pin-point location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500-PS & • Extremely easy to operate SD500-PSDA • Corrosion-resistant gold-plated contacts. Addressable Pull • Reflective label makes it easier Station to locate in low light The SD500-PS is a single action Operation addressable fire pull station, and The SD500-PS/PSDA single action the SD500--PSDA is a dual action pull stations are operated by a pull addressable fire pull station. The on the front pull cover of the SD500-PS/PSDA feature rugged station. A plunger switch, wired to metal construction A terminal strip a self contained addressable on back of the pull station allows module, is released as the pull interconnection of the pull station to station opens to initiate the alarm. the SLC of an IntelliKnight control Once operated, the cover hangs panel. The SD500-PS/PSDA is down and can be seen up to 100 designed for indoor use in non- feet away. The pull station is reset explosive environments. The by returning the front cover to the normally open initiating point normal upright position and contacts are gold-plated to avoid relocking the station with a reset risk of corrosion. The SD500- key. The reset keys are the same PS/PSDA has been tested by UL keys used on Silent Knight for compliance to the requirements enclosures. of the Americans with Disabilities The SD500-PS/PSDA includes a ACT (ADA). status LED which blinks, indicating SD500-PS Features that the addressable module is Ambient Temperature: 32°F to 120°F • UL Listed communicating with the loop. The (0°C to 49°C) status LED lights continuously Mounting: Single gang • CSFM listed during an alarm. A dip switch on box - • ADA compliant Optional Red Surface Mount Box PS-SMBB the addressable module is used to • Key reset (Same key as Silent set the unique address. Knight enclosures) Specifications • Surface mount back box Operating Voltage: 24VDC available Standby Current: .55mA • Terminals - accept up to 14 Alarm Current: .55mA gauge wire INTELLIKNIGHT ACCESSORY SD500-PS and SD500-PSDA Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. Wiring Mounting to Single Mounting to Optional Gang Electrical Box Surface Mount Box SD500-PSDA Installing SD500-LK Dimensions 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM# 350342, Rev. 09/03 FAX: 763-493-6475 Copyright © 2003 Silent Knight World Wide Web: http://www.silentknight.com INTELLIKNIGHT ACCESSORY Addressable Photoelectric Smoke Detector Detect smoldering fires quickly and get help fast with IntelliKnight® photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-PHOTO photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-PHOTO compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other IntelliKnight detector models, the SD505-PHOTO offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you’ve come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-PHOTO approximately every 15 seconds, indicating that the head is Analog / Addressable communicating with the loop. The Photoelectric Type Smoke LED lights continuously during the Detector alarm period. The SD505-PHOTO is particularly suited to detecting dense smoke Features typical of fires involving materials • Low profile, 2 inches, including such as soft furnishings, plastic, base foam or other similar materials • Simple and reliable addressing which tend to smolder and produce without mechanical switches large visible particles. SD505-PHOTO Smoke Detector • Automatic compensation for The detector features automatic sensor contamination compensation for contamination • Built-in fire test feature Ambient Temperature: 32ºF to and a simple detector calibration • Simple detector calibration 120ºF (0ºC to 49ºC) test procedure that can be run from testing through the control panel the panel or remotely (using the or remotely through a Mounting: 4†Square, 4†OCT, WindowsTM based downloading WindowsTM based computer Single gang mud ring software). software. Relative Humidity: 85% non- Operation • Vandal-resistance locking condensing features The SD505-PHOTO units made up Air Velocity: 0 - 300 FPM of an LED light source and a silicon • Field cleanable photo diode receiving element. In a • UL listed, meets NFPA 72 Ch 7 Compatible Bases: SD505-6AB normal standby condition, the requirements (Sold Separately) SD505-6IB receiving element receives no light • CSFM approved SD505-6RB from the pulsing light source. In the • MEA approved SD505-6SB event or fire, smoke enters the • FM Approved detector and light is reflected from Specifications the smoke particles to the receiving Operating Voltage: 24-41 VDC element. Current Consumption: The light received is converted into an electronic signal. Under normal Standby: .55 mA P/N 350225 Rev G conditions, the status LED blinks Alarm: .55 mA © 2015 Honeywell International Inc. INTELLIKNIGHT ACCESSORY Model SD505-PHOTO Addressable Photoelectric Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-PHOTO. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight’s IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-HEAT Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-PHOTO shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Model SD505-6AB Detector Base Model SD505-PHOTO Detector Head (front view) (front view) This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications SpectrAlert® Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. • Plug-in design with minimal intrusion into the back box With white and red plastic housings, wall and ceiling mounting • Tamper-resistant construction options, and plain and FIRE-printed devices, SpectrAlert Advance • Automatic selection of 12- or 24-volt operation at 15 and can meet virtually any application requirement. 15/75 candela Like the entire SpectrAlert Advance product line, ceiling-mount • Field-selectable candela settings on ceiling units: 15, 15/75, 30, strobes and horn strobes include a variety of features that increase 75, 95, 110, 115, 135, 150, 177, and 185 their application versatility while simplifying installation. All devices • Horn rated at 88+ dBA at 16 volts feature a plug-in design with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity To further simplify installation, SpectrAlert Advance utilizes a before device installation universal mounting plate so you can mount them to a wide array • Electrically Compatible with legacy SpectrAlert devices of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. • Compatible with MDL3 sync module • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Agency Listings 7125-1653:0186 (indoor strobes) 7125-1653:0188 (horn strobes, S4011 (chimes, horn strobes, horns) 3023572 MEA452-05-E chime strobes) S5512 (strobes) 7135-1653:0189 (horns, chimes) SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17â„8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuitâ„¢ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11â„16 × 4 11â„16 × 2 1â„8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter × 2.5" high (173 mm diameter × 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCR, SBBCW) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS10101 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 8–17.5 Volts 16–33 Volts Candela DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd) 8–17.5 Volts 16–33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd) 16–33 Volts 16–33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Strobe Tones and Sound Output Data Horn Strobe Output (dBA) 8–17.5 16–33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7†Coded High 82 82 88 88 93 92 101 101 8†Coded Medium 78 78 85 85 90 90 97 98 9†Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn strobes. AVDS10101 4.8" 1.85" 5.703" SpectrAlert Advance Dimensions 6.8" 6.922" 2.5" 4.7" 2.5" Dia. dia. 2.5" 5.6" Ceiling-mount horn strobes Ceiling back box surface mount back box SpectrAlert Advance Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2R 2-Wire Horn Strobe, Standard cd, Red SCR Strobe, Standard cd, Red PC2R-P 2-Wire Horn Strobe, Standard cd, Red, Plain SCRH Strobe, High cd, Red (no “FIREâ€) marking SCW Strobe, Standard cd, White PC2RH 2-Wire Horn Strobe, High cd, Red SCW-P Strobe, Standard cd, White, Plain (no “Fireâ€) marking PC2W 2-Wire Horn Strobe, Standard cd, White SCWH Strobe, High cd, White PC2W-P 2-Wire Horn Strobe, Standard cd, White, Plain Accessories (no “FIREâ€) marking SBBCR Surface Mount Back Box, Ceiling, Red PC2W-SP 2-Wire Horn Strobe, Standard cd, White, “Fuego†SBBCW Surface Mount Back Box, Ceiling, White marking PC2WH 2-Wire Horn Strobe, High cd, White PC2WH-P 2-Wire Horn Strobe, High cd, White, Plain (no “FIREâ€) marking PC2WH-SP 2-Wire Horn Strobe, High cd, White, “Fuego†PC4R 4-Wire Horn Strobe, Standard cd, Red PC4RH 4-Wire Horn Strobe, High cd, Red PC4W 4-Wire Horn Strobe, Standard cd, White Notes: All -P models have a plain housing (no “FIRE†marking on cover) All -SP models have “FUEGO†marking on cover “Standard cd†refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd†refers to strobes that include 135, 150, 177, and 185 candela settings. ©2015 System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit systemsensor.com Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product information, including the latest version of this data sheet. AVDS10102 • 03/15 Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. • Plug-in design with minimal intrusion into the back box With white and red plastic housings, wall and ceiling mounting • Tamper-resistant construction options, and plain and FIRE-printed devices, SpectrAlert Advance • Automatic selection of 12- or 24-volt operation at can meet virtually any application requirement. 15 and 15/75 candela Like the entire SpectrAlert Advance product line, wall-mount horns, • Field-selectable candela settings on wall units: 15, 15/75, strobes, and horn strobes include a variety of features that increase 30, 75, 95, 110, 115, 135, 150, 177, and 185 their application versatility while simplifying installation. All devices • Horn rated at 88+ dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. • Universal mounting plate for wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage, SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring, so installers can test wiring continuity before the device is installed. • Compatible with MDL3 sync module • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Agency Listings 7125-1653:186 (indoor strobes) 7125-1653:188 (horn strobes, S4011 (chimes, horn strobes, horns) 3023572 MEA452-05-E chime strobes) S5512 (strobes) 7135-1653:189 (horns, chimes) SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17â„8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuitâ„¢ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411â„16 × 411â„16 × 21â„8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6Ë L × 4.7Ë W × 2.5Ë D (142 mm L × 119 mm W × 64 mm D) Horn Dimensions 5.6Ë L × 4.7Ë W × 1.3Ë D (142 mm L × 119 mm W × 33 mm D) Wall-Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS) 5.7Ë L × 4.8Ë W × 0.35Ë D (145 mm L × 122 mm W × 9 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8–17.5 Volts 16–33 Volts 8–17.5 Volts 16–33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd) 8–17.5 Volts 16–33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd) 16–33 Volts 16–33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8–17.5 16–33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7†Coded High 82 82 88 88 93 92 101 101 8†Coded Medium 78 78 85 85 90 90 97 98 9†Coded Low 74 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn strobes. SpectrAlert Advance Dimensions 4.7Ë 2.5Ë 6.8Ë Dia. 2.5Ë 5.6Ë Wall-mount horn strobes SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Wall Strobes (cont.) P2R 2-Wire Horn Strobe, Standard cd, Red SRH Strobe, High cd, Red P2R-P 2-Wire Horn Strobe, Standard cd, Red, Plain SRH-P Strobe, High cd, Red, Plain P2R-SP 2-Wire Horn Strobe, Standard cd, Red, “FUEGO†SRH-SP Strobe, High cd, Red, “FUEGO†P2RH 2-Wire Horn Strobe, High cd, Red SW Strobe, Standard cd, White P2RH-P 2-Wire Horn Strobe, High cd, Red, Plain SW-P Strobe, Standard cd, White, Plain P2W 2-Wire Horn Strobe, Standard cd, White SWH Strobe, High cd, White P2W-P 2-Wire Horn Strobe, Standard cd, White, Plain SWH-P Strobe, High cd, White, Plain P2WH 2-Wire Horn Strobe, High cd, White Horns P2WH-P 2-Wire Horn Strobe, High cd, White, Plain HR Horn, Red P4R 4-Wire Horn Strobe, Standard cd, Red HW Horn, White P4R-P 4-Wire Horn Strobe, Standard cd, Red, Plain Accessories P4RH 4-Wire Horn Strobe, High cd, Red TR-HS Trim Ring, Wall, Red P4W 4-Wire Horn Strobe, Standard cd, White SBBR Indoor Surface Mount Back Box, Red Wall Strobes SBBW Indoor Surface Mount Back Box, White SR Strobe, Standard cd, Red SR-P Strobe, Standard cd, Red, Plain SR-SP Strobe, Standard cd, Red, “FUEGO†Notes: All -P models have a plain housing (no “FIRE†marking on cover) All -SP models have “FUEGO†marking on cover “Standard cd†refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd†refers to strobes that include 135, 150, 177, and 185 candela settings. 3825 Ohio Avenue • St. Charles, IL 60174 ©2014 System Sensor. Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. www.systemsensor.com AVDS10201 • 1/14 Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic • Weatherproof per NEMA 4X, IP56 housings, wall or ceiling mounting options, and plain or FIRE-printed • Listed to UL 1638 (strobe) and UL 464 (horn) devices, SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement, including indoor, outdoor, wet, and dry applications in legacy SpectrAlert products temperatures from −40°F to 151°F. • Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, Like the entire SpectrAlert Advance line, outdoor horns, strobes, 135, 150, 177, and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12- or 24-volt operation at 15 and that increase application flexibility and simplify installation. First, 15/75 candela field-selectable settings, including candela, automatic selection of • Rotary switch for horn tone and three volume selections 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. • Horn rated at 88+ dBA at 16 volts • Rated from –40°F to 151°F Next, SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications. This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without • Plug-in design with minimal intrusion into the back box mounting the devices and exposing them to potential construction • Tamper-resistant construction damage. Once the plates are mounted, all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- Agency Listings out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with ¾-inch top and bottom conduit entries and ¾-inch 7300-1653:187 (outdoor strobes) 7125-1653:188 (horn strobes, knock-outs at the back. A screw-in NPT plug with an O-ring gasket S4011 (chimes, horn strobes, horns) chime strobes) S3593 (outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189 (horns, chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuitâ„¢ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between −40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature –40°F to 151°F (–40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6Ë L × 4.7Ë W × 2.5Ë D (142 mm L × 119 mm W × 64 mm D) Horn Dimensions 5.6Ë L × 4.7Ë W × 1.3Ë D (142 mm L × 119 mm W × 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7Ë L × 5.1Ë W × 2.0Ë D (145 mm L × 130 mm W × 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8–17.5 Volts 16–33 Volts 8–17.5 Volts 16–33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd) 8–17.5 Volts 16–33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd) 16–33 Volts 16–33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output (dBA) candela ratings must be reduced in accordance with 8–17.5 16–33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output (cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at –40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 82 82 88 88 93 92 100 100 75 44 Temporal 95 70 5 Non- Medium 78 78 85 85 90 90 98 98 110 110 Temporal 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7†Coded High 82 82 88 88 93 92 101 101 177 177 8†Coded Medium 78 78 85 85 90 90 97 98 185 185 9†Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS01201 SpectrAlert Advance Diagrams 4.7Ë 2.5Ë 6.8Ë Dia. 2.5Ë 5.6Ë Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK*†2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*†2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*†2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*†2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RK†4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*†Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*†Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*†Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*†Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRK†Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: * Add “-P†to model number for plain housing (no “FIRE†marking on cover), e.g., P2RK-P. †Add “-R†to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. “Standard cd†refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd†refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. ©2012 System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit systemsensor.com Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product information, including the latest version of this data sheet. AVDS01201 • 3/12 Effective September 2016 Technical Data TD450055EN Supersedes June 2011 Wheelock MB Motor bells Description The Wheelock MB motor bells provide a specifically designed motor bell for fire and life safety alarm systems. The Wheelock MB bells include higher dBA, low current draw, built-in trimplate for semi-flush mounting, low frequency aluminum shells, and low RFI noise. The motor for MB bells is a durable, high-torque permanent magnet motor selected for its high performance and long life. These DC vibrating MB motor bells are offered in 6†and 10†shell sizes in both 12 and 24 VDC models. The RSSP Sync/Non-Sync retrofit plates are used in conjunction 10â€BELL with the MB motor bell when combination appliances are required. The RSSP retrofit plates are available with either multi-candela or single candela strobes and easily mount to a 4†square or Wheelock SBL-2 backbox. All RSSP strobe appliances meet or exceed the requirements of NFPA 72 (National Fire Alarm Code), ANSI 117.1 (American National Standard for Accessible and Usable Buildings and Facilities), ADA (Americans with Disabilities Act) and UL Standard 1971 (Signaling Devices for the Hearing Impaired). 6â€BELL The RSSP retrofit plates may be synchronized when installed with the Wheelock Series DSM, Sync Modules or Wheelock Power Supplies with Wheelock patented sync protocol. Wheelock synchronized strobes offer an easy way to comply with ADA requirements concerning photo-sensitive epilepsy. RSSP REMOTE PLATE Technical Data TD450055EN Wheelock MB Effective September 2016 Features & benefits Drawings • Meets OSHA 29 Part 1910.165 2.37 • High sound output with low current draw ø10.0 • Low frequency aluminum shells for better audibility through walls, doors and other structures • 6†and 10†shell sizes in 12 or 24 VDC models • Integral RFI suppression to minimize included noise on the NAC circuit • Mounting options for surface, semi-flush, outdoor, and concealed conduit installation • Built-in trimplate makes semi-flush mounting simpler and less expensive • Screw terminals permit fast in-out field wiring of #12 to #18 AWG wire Figurt 1. MB-G10 frNno and sidt vitws • Polarized for DC supervision of NAC circuits • Operates on filtered or unfiltered DC 2.37 ø6.0 • For combined audible (bell) and visual signaling, convenient retrofit plate assemblies are available with Multi-Candela or Single candela strobes (Refer to Fire Alarm Products Catalog for Series RSSP Sync/Non-Sync Strobes specifications and technical information) NNote: All CAUTIONS and WARNINGS are identified by the symbol . All warnings are printed in bold capital letters. WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION Figurt 2. MB-G6 frNno and sidt vitws INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Approvals & compliances • Approvals include: UL Standard 464, Factory Mutual (FM), California State Fire Marshal (CSFM), New York (MEA) and Chicago (BFP) • Meets OSHA 29 Part 1910.165 Tablt 1. SptcificaoiNns and Nrdtring infNrmaoiNne: MB mNdtls Input Voltage Average RMS Model Number Order Code Shell Size (VDC) Current UL Max a dBA @ 10 ft. Mounting Options MB-G6-12-R 3942 6†12 0.060 0.090 MB-G6-12-S 4221 6†12 0.060 0.090 MB-G6-24-R 3941 6†24 0.030 0.040 MB-G6-24-S 4222 6†24 0.030 0.040 92 D, E, J, K, N, O, P, R, S MB-G10-12-R 3944 10†12 0.060 0.090 MB-G10-12-S 4223 10†12 0.060 0.090 MB-G10-24-R 3943 10†24 0.030 0.040 MB-G10-24-S 4224 10†24 0.030 0.040 a RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. NNotse: 1. Typical dBA at 10 feet is measured in an anechoic chamber. NNotse: 2. For bells all 12 VDC models are UL rated for 9.0 to 15.6 VDC and all 24 VDC models for 18.0 to 31.0 VDC. 2 EATON www.eaton.com Wheelock MB Technical Data TD450055EN Effective September 2016 Tablt 2. SptcificaoiNns and Nrdtring infNrmaoiNne: RSSP mNdtls Nominal Voltage Strobe Average Current Model Number Order Code (VDC) Candela (AMPS) at Listed VDC UL Max a Mounting Options b RSSP-24MCW-FR 9402 24 15/30/75/110 0.041/0.063/0.109/0.140 0.060/0.092/0.165/0.220 D, E, Z RSSP-241575W-FR 7793 24 15 (75 on-axis) 0.060 0.090 D, E, Z RSSP-121575W-FR 7798 12 15 (75 on-axis) 0.152 0.255 D, E, Z a RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. b Refer to data sheet TD450028EN for mounting options. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters’ Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and engineers specifications The alarm appliances shall be Wheelock MB vibrating motor bells or approved equal. They shall be UL Standard 464 Listed for Fire Protective Service. Shells shall be aluminum in 6†or 10†diameter. Sound output at 10 feet shall be 92 dBA. The bells shall incorporate a permanent magnet motor and suppression circuitry to minimize RFI. They shall include a built-in trimplate for semi-flush mounting to a standard 4†square backbox or surface mounting to Wheelock’s indoor BB backbox or outdoor WBB backbox. For bell strobe applications, retrofit plates Wheelock RSSP with multi-candela or single candela strobes shall be used. All bell models shall be polarized for line supervision and shall have screw terminals for in/out field wiring of #12 to #18 AWG wire. Operating voltage shall be nominal 24 VDC or 12 VDC. Finish on all models shall be textured enamel. NNote:Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock, Inc., dba Eaton, standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3-YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07740 www.eaton.com/massnotification © 2016 Eaton All Rights Reserved Eaton is a registered trademark. Printed in USA Publication No. TD450055EN All other trademarks are property September 2016 of their respective owners. Data Sheet NP SERIES - NP 12-12 Reliability is your Security Utilizing the latest advance design Oxygen Recombination Technology, Yuasa have applied their 80 years experience in the lead acid battery field to produce the optimum design of Sealed Lead Acid batteries. FEATURES ï‚·ï€ Superb recovery from deep discharge. ï‚·ï€ Electrolyte suspension system. ï‚·ï€ Gas Recombination. ï‚·ï€ Multipurpose: Float or Cyclic use. ï‚·ï€ Usable in any orientation. Terminals ï‚·ï€ Superior energy density. NP batteries are manufactured using a range of terminals which vary in size and type. Please refer to details as shown. ï‚·ï€ Lead calcium grids for extended life. ï‚·ï€ Manufactured World wide. Operation in any Orientation ï‚·ï€ Application specific designs. The combination of sealed construction and Yuasa’s unique electrolyte suspension system allows operation in any Technical Features orientation, with no loss of performance or fear of electrolyte Sealed Construction leakage. Yuasa’s unique construction and sealing technique Valve Regulated Design ensures no electrolyte leakage from case or terminals. The batteries are equipped with a simple, safe, low pressure Electrolyte Suspension System venting system which releases excess gas and automatically All NP batteries utilize Yuasa’s unique electrolyte suspension reseals should there be a build up of gas within the battery due system incorporating a microfine glass mat to retain the to severe overcharge. Note. On no account should the battery be maximum amount of electrolyte in the cells. The electrolyte is charged in a sealed container. retained in the separator material and there is no free General electrolyte to escape from the cells. No gels or other contaminants are added. Specifications Control of Gas Generation Nominal Capacity (Ah) NP12-12 The design of Yuasa’s NP batteries incorporates the very latest oxygen recombination technology to effectively control the 20hr to 1.75vpc 30ºC 12 generation of gas during normal use. 10hr to 1.75vpc 20ºC 11.1 Low Maintenance Operation 5hr to 1 .70vpc 20ºC 10 Due to the perfectly sealed construction and the 1 hr to 1 .60vpc 20ºC 7.2 recombination of gasses within the cell, the battery is almost Voltage 12 maintenance free. Energy Density (Wh.L.20hr) 1 04 Terminals Layout Specific Energy (Wh.kg.20hr) 36 Int. Resistance (m.Ohms) 1 6 Maximum discharge (A) 75 Short Circuit current (A) 360 Dimensions (mm) Length 151 Width 98 Height overall 97.5 Weight (Kg) 4.05 Terminal D Layout 4 Terminal Torque Nm - www.yuasabatteries.com NP Data Sheet NP SERIES - NP 12-12 Lead Calcium Grids Long shelf Life The heavy duty lead calcium alloy grids provide an extra margin The extremely low self discharge rate allows the battery to be of performance and life in both cyclic and float applications and stored for extended periods up to one year at normal ambient give unparalleled recovery from deep discharge. temperatures with no permanent loss of capacity. Long Cycle Service Life Operating Temperature Range Depending upon the average depth of discharge, over a The batteries can be used over a broad temperature range thousand discharge/charge cycles can be expected. permitting considerable flexibility in system design and location. Float Service Life Charge – 15°C to 50°C The expected service life is five years in float standby Discharge – 20°C to 60°C applications. Storage – 20°C to 50°C (fully charged battery) Separators The use of the special separator material provides a very efficient insulation between plates preventing inter-plate short circuits and prohibiting the shedding of active materials. Distributed by Yuasa Battery Inc. 2901 Montrose Ave Laureldale, PA 19605 www.yuasabatteries.com Registered number 1548820 Cat. No. NP 12-12 March 09 architect + engineer TO FACP NAC #4 B C FPLR 16/2 D E F G H 75cd WP 1 SOLUTIONS EXIT EXIT EXISTING SPRINKLER ROOM DRYING DRYING DRYING DRYING MATCHLINE SEE SHEET FA 1.1 Est. 1994 15cd TO FACP NAC #1 EXISTING FPLR 16/2 30cd 30cd 30cd 30cd ELECTRICAL ROOM 30cd 30cd TO FACP NAC #3 FPLR 16/2 SECURITY EXISTING BREAK ROOM 2 15cd project no. | #02022018 STORAGE 30cd NAC #1 AREA 30cd EOLR owner 15cd CONTROLLED HALL EXISTING OFFICE 15cd 15cd 15cd 30cd 30cd PACKAGING 3 NAC #3 30cd 30cd EOLR CONTROLLED HALL 15cd EXISTING OFFICE TO FACP NAC #2 FPLR 16/2 4 CONTROLLED HALL DAVINCI, LLC. TO FACP S-BUS GROW ROOM GROW ROOM GROW ROOM FPLR 18/4 #3 #4 #5 NAC #4 15cd EOLR 15cd project info 15cd 7220 201st STREET N.E. 15cd ARLINGOTN, WA. 98223 30cd 30cd 30cd fire alarm TEMPORARY GROW ROOM MODELNUMBERTRADENAMEPRODUCTMATERIALTRADENAMEPRODUCTMATERIAL MODELNUMBERTRADENAMEPRODUCTMATERIALTRADENAMEPRODUCTMATERIAL MODELNUMBERTRADENAMEPRODUCTMATERIAL MODELNUMBERTRADENAMEPRODUCTMATERIAL MODELNUMBERTRADENAMEPRODUCTMATERIAL MODELNUMBERTRADENAMEPRODUCTMATERIAL MODELNUMBERTRADENAMEPRODUCTMATERIAL MODELNUMBERTRADENAMEPRODUCTMATERIALTRADENAMEPRODUCTMATERIAL MODELNUMBERTRADENAMEPRODUCTMATERIALTRADENAMEPRODUCTMATERIAL 15cd 15cd issue dates 5 FINISHED GOODS submission: date SHIPPING PERMIT / BID 02.02.2018 security 15cd 15cd 75cd 75cd 75cd EXISTING revisions: OFFICE GROW ROOM GROW ROOM POTTING # description date #1 #2 ROOM NAC #2 EOLR 30cd 15cd 30cd 30cd 30cd EXISTING STORAGE equipment EXIT EXIT EXIT EXIT 6 EXISTING STORAGE mechanical B C D E F SLC LOOP EXIT FPLR 18/2 7 designed by: CB checked by: BB seal architectural G H structural sheet info landscape FIRE ALARM FIRST FLOOR MATCHLINE SEE SHEET FA 1.1 TENANT IMPROVEMENT FIRST FLOOR - FIRE ALARM FLOOR PLAN FAFA1.0 civil 5/13/2016 9:37:40 AM architect + engineer I J K L M SOLUTIONS MATCHLINE SEE SHEET FA 1.0 Est. 1994 30cd 30cd 30cd 30cd SECURITY TO FCPS NAC #1 FPLR 16/2 project no. | #02022018 STORAGE AREA owner EXIT NAC #1 EOLR 30cd 30cd 30cd 30cd DAVINCI, LLC. GROW ROOM GROW ROOM #6 #7 project info 7220 201st STREET N.E. ARLINGOTN, WA. 98223 30cd 30cd 30cd 30cd fire alarm 15cd BULK CHEMICAL AND issue dates WATER STORAGE submission: date PERMIT / BID 02.02.2018 security NAC #3 EOLR NAC #2 EOLR revisions: CLONING MOTHERS 30cd ROOM ROOM 30cd # description date 30cd 30cd equipment SLC LOOP TO FCPS NAC #3 FPLR 18/2 FPLR 16/2 15cd HASH EXISTING SOIL AND POTTING ROOM STORAGE SUPPLIES / RECEIVING TO FCPS NAC #2 mechanical FPLR 16/2 30cd 30cd 95cd designed by: CB checked by: BB seal architectural HASH ROOM 30cd EXIT 8 structural I J K L M sheet info landscape FIRE ALARM FIRST FLOOR MATCHLINE SEE SHEET FA 1.0 TENANT IMPROVEMENT FIRST FLOOR - FIRE ALARM FLOOR PLAN FAFA1.1 civil 5/13/2016 9:37:40 AM ✔ ✔ 7220 201st Street NE Arlington WA 98223 00793300002300 1 15000 25000.00 Jeff Hubbard 212-390-1235 7220 201st Street NE Arlington WA 98223 Jeff Hubbard 212-390-1235 212-390-1235 jeff@constellationcannabis.com 7220 201st Street NE Arlington WA 98223 Champion Security Solutions 206-919-6552 PO Box 12729 Mill Creek WA 98082 CHAMPSS841P1 10/21/2018 Daniel Keenan dan.k@cfsprosnw.com Champion Security Solutions 206-919-6552 PO Box 12729 Mill Creek WA 98082 CHAMPSS841P1 10/21/2018 02/05/2018 Amanda Becker CITY OF ARLINGTON INSPECTION CARD No building construction shall be commenced until permit holder INSPECTION RECORD SHALL or his agent has posted this Inspection Record Card in a REMAIN AT JOB SITE conspicuous place on the premises. OWNER: CONTRACTOR: JOB ADDRESS: LOT NUMBER TYPE GROUP NATURE of WORK: USE of BUILDING: PERMIT No: DATE ISSUED: INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB DEPARTMENT INSPECTION DATE(S) PASS FAIL INITIALS FOOTING BUILDING FOUNDATION (360) 403-3417 UNDERFLOOR SHEARWALL PLUMBING (groundwork) ROUGH PLUMBING GAS PIPING ROUGH HEATING & VENTILATION FRAMING INSULATION WALLBOARD (SHEAR/RATED WALLS) CEILING GRID STRUCTURAL SLAB CROSS CONNECTION CONTROL IN PREMISE PUBLIC WORKS GRADING (360) 403-3457 TEMPORARY TECSP ASBUILTS APPROVED MAINTENANCE BOND STORM DRAINAGE SYSTEM PAVING, SIGNAGE & MARKINGS LANDSCAPING PLANNING CONDITIONS ONSITE UTILITIES WATER ONSITE UTILITIES SEWER Sewer OFFSITE UTILITIES WATER (360) 403-3508 OFFSITE UTILITIES SEWER SEWER PRETREATMENT Water CROSS CONNECTION CONTROL PREMISE (360) 403-3526 SIDE SEWER/ CLEANOUT/FINAL WATER SERVICE INSTALLATION WATER SERVICE FINAL FIRE DEPARTMENT (360) 403-3526 HYDRO/FLUSH (360) 403-3607 UNDERGROUND**INCL FDC (360) 403-3607 FIRE ALARM /AUTOMATIC SPRINKLER (360) 403-3417 HOOD SUPPRESSION SYSTEM (360) 403-3607 FINAL FIRE WALK-THROUGH (360) 403-3417 FINAL INSPECTION ALL SIGNATURE BLOCKS MUST BE COMPLETE Permit #: 1830 Permit Date: 02/08/18 Permit Type: FIRE ALARM Project Name: Streadfast Star Applicant Name: Champion Security Solutions Applicant Address: P.O. Box 12729 Applicant, City, State, Zip: Mill Creek, WA 98082 Contact: Dan Keenan Phone: 206-919-6552 Email: dan.k@cfsprosnw.com Scope of Work: I-502 Valuation: 25000.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 03/06/2018 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Launa Black Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 282 Plastics & STEADFAST STAR 00793300002300 7220 201ST ST NE Synthetic Resins, LLC Rubber, Ex. Glass Contractors Contractor Primary Contact Phone Address Contractor Type License License # Champion Security CONSTRUCTION Dan Keenan 206-919-6552 P.O. Box 12729 Labor & Industries CHAMPSS841P1 Solutions CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status FA00. FIRE ALARM 03/27/2018 03/27/2018 BUILDING Completed FINAL Plan Reviews Date Review Type Description Assigned To Review Status 02/08/2018 FIRE ALARM BUILDING Fees Fee Description Notes Amount Fire Alarm Plan Review Fee $100.00 Fire System Plan Review Table 4-1 $563.68 Processing/Technology $25.00 Total $688.68 Attached Letters Date Letter Description 03/03/2018 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount Champion Security 03/03/2018 68802237 cc $688.68 Solutions Outstanding Balance $0.00 Notes Date Note Created By: Amanda from Champion will be sending a letter from the owner that they will be performing 02/20/2018 Kristin Foster the work. Uploaded Files Date File Name 04/30/2018 3423363-7220 201st Street NE.docx 03/06/2018 3133337-1830_Issued Permit.pdf 02/21/2018 3093641-External - Fire Permit -- 7220 201st St NE Arlington WA 98223.msg 02/08/2018 3024340-Fire Alarm Cut Sheets.pdf 02/08/2018 3024337-Fire Alarm Specs_.2018.pdf 02/08/2018 3024335-Fire_Alarm_Permit_Application_D1a2KXINDGu77k.pdf