Loading...
HomeMy WebLinkAbout8205 179th Pl Ne_BLD6647_2025 Submittal Split System Cooling 2.5 Ton 5A7A3030A1000A NNoottee:: “Graphics in this document are for representation only. Actual model may differ in appearance.” Septemebr 2024 55AA77AA33003300AA--SSUUBB--11AA--EENN Outline Drawing Model Base A B C D E F G H J K 730 829 756 127 76 197 60 508 5A7A3030A 3 3/4 5/16 (28-3/4) (32-5/8) (29-3/4) (5) (3) (7-3/4) (2-3/8) (20) SOUND POWER LEVEL A-Weighted Sound Full Octave Sound Power [dB] Model Power Level [dB(A)] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 5A7A3030A 73 79 69 67 70 70 64 59 53 Note:Rated in accordance with AHRI Standard 270-2008 *For reference only. 2 5A7A3030A-SUB-1A-EN Product Specifications OUTDOOR UNIT(a) (b) 5A7A3030A1000A (a) Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program, which is based on AHRI standard POWER CONNS. - V/PH/HZ(c) 208/230/1/60 210/240. MIN. BRCH. CIR. AMPACITY 16 (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR BR. CIR. PROT. RTG. - MAX. (AMPS) 25 circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on COMPRESSOR DURATION®- SCROLL this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit NO. USED - NO. STAGES 1 - 1 selection current. VOLTS/PH/HZ 208/230/1/60 (e) Use start components only when compressor is found to enter locked rotor condition and will not start or when lights dim at compressor R.L. AMPS(d)- L.R. AMPS 10.3 - 67.8 start. No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. FACTORY INSTALLED Optional kit shown. START COMPONENTS(e) NO (f) Standard Air - Dry Coil - Outdoor (g) This value approximate. For more precise value see unit nameplate. INSULATION/SOUND BLANKET NO (h) For standard, recommended linear length and lift applications, see the Subcool Charging Chart in IOM. For greater lengths and other COMPRESSOR HEAT NO applications, consult refrigerant piping software Pub. No. 32-3312-xx (xx denotes latest revision). OUTDOOR FAN PROPELLER (i) The outdoor condensing units are factory charged with the system DIA. (IN.) - NO. USED 23.02 - 1 charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil TYPE DRIVE - NO. SPEEDS DIRECT - 1 match. Always verify proper system charge via subcooling (TXV/EEV) or superheat (fixed orifice) per the unit nameplate. CFM @ 0.0 IN. W.G.(f) 2675 NO. MOTORS - HP 1 - 1/8 MOTOR SPEED R.P.M. 825 VOLTS/PH/HZ 208/230/1/60 F.L. AMPS 0.71 OUTDOOR COIL - TYPE SPINE FIN™ ROWS - F.P.I. 1 - 24 FACE AREA (SQ. FT.) 16.25 TUBE SIZE (IN.) 3/8 REFRIGERANT LBS. - R-454B (O.D. UNIT) (g) 3 LBS., 2 OZ FACTORY SUPPLIED YES VALVE CONNECTION SIZE - IN. O.D. 3/4 GAS VALVE CONNECTION SIZE - IN. O.D. 5/16 LIQ. LINE SIZE - IN. O.D. GAS(h) (i) 3/4 LINE SIZE - IN. O.D. LIQ. 5/16 CHARGING SPECIFICATIONS SUBCOOLING 10°F DIMENSIONS H X W X D CRATED (IN.) 34 x 30 x 33 WEIGHT SHIPPING (LBS.) 189 NET (LBS.) 161 5A7A3030A-SUB-1A-EN 3 Mechanical Specification Options General CCoommpprreessssoorr The outdoor condensing units are factory charged with The compressor features internal over temperature and the system charge required for the outdoor condensing pressure protection. Other features include: Centrifugal unit, ten (10) feet of tested connecting line, and the oil pump and low vibration and noise. smallest rated indoor evaporative coil match. This unit CCoonnddeennsseerr CCooiill is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are The outdoor coil provides low airflow resistance and matched with a wide selection of air handlers and efficient heat transfer. The coil is protected on all four furnace coils that are AHRI certified. The unit is certified sides by louvered panels. to UL 60335-2-40. Exterior is designed for outdoor LLooww AAmmbbiieenntt CCoooolliinngg application. As manufactured, this system has a cooling capacity to Casing 55°F. The addition of an evaporator defrost control Unit casing is constructed of heavy gauge, galvanized permits operation to 40°F. The addition of an steel and painted with a weather-resistant powder evaporator defrost control with TXV permits low paint finish. The corner panels are prepainted. All ambient cooling to 30°F. panels are subjected to our 1,000 hour salt spray test. The addition of the BAYLOAM107A low ambient kit Refrigerant Controls permits ambient cooling to 20°F. Refrigeration system controls include condenser fan, TThheerrmmoossttaattss – Cooling only and heat/cooling (manual compressor contactor and low and high pressure and automatic change over). Sub-base to match switches. A factory supplied, field installed liquid line thermostat and locking thermostat cover. drier is standard. 4 5A7A3030A-SUB-1A-EN About American Standard Heating and Air Conditioning American Standard has been creating comfortable and affordable living environments for more than a century. For more information, please visit www.americanstandardair.com. The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 5A7A3030A-SUB-1A-EN 20 Sep 2024 Supersedes (New) ©2024 American Standard Heating and Air Conditioning Permit #: 6647 Permit Date: 07/28/25 Permit Type: RESIDENTIAL MECHANICAL Project Name: DENNY MECH PERMIT Applicant Name: CM HEATING Applicant Address: 1500 INDUSTRY ST #200 Applicant, City, State, Zip: EVERETT Contact: SABRINA KENNARD Phone: 4252590550 Email: PERMITS@CMHEATING.COM Scope of Work: AC ADD Valuation: 15927.00 Square Feet: 2460 Number of Stories: 1 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 07/29/2025 Permit Expires: 01/28/2026 Form Permit Type: RESIDENTIAL MECHANICAL Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 910 SCOTT ERIC J & 01047900007300 8205 179TH PL NE UNDEVELOPED DEBORAH L (VACANT) LAND Contractors Contractor Primary Contact Phone Address Contractor Type License License # 1500 INDUSTRY CONSTRUCTION Plumbing CM HEATING INC 425-259-0550 CMHEAHL750LP ST STE 200 CONTRACTOR Contractor 1500 INDUSTRY CONSTRUCTION Construction CM HEATING INC 425-259-0550 CMHEAHL751W ST STE 200 CONTRACTOR Contractor 1500 INDUSTRY CONSTRUCTION CM HEATING INC 425-259-0550 UBI 605890285 ST STE 200 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C14. Available between 1pm and 08/08/2025 MECHANICAL 5pm. Tried to call back and 08/14/2025 08/14/2025 BUILDING Approved FINAL confirm, VM Box is full. Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Air Cond. Unit ≤ 100 BTU/h Enter # of units $15.00 Mechanical Base Permit Fee $25.00 Credit Card Service $4.20 Total $144.20 Attached Letters Date Letter Description 07/29/2025 Building Permit 07/28/2025 Web Form- Residential Mechanical Application Payments Date Paid By Description Payment Type Accepted By Amount XBP Conf: 07/28/2025 $140.00 238429155 07/28/2025 Matt Zivanov 238429155 Hannah Hardwick $4.20 Outstanding Balance $0.00 Notes Date Note Created By: 07/28/2025 emailed applicant for the site plan Hannah Hardwick Uploaded Files Date File Name 07/29/2025 27563678-2025_BLD6647_IssuedPermit.pdf 07/29/2025 27552420-20250729_BLD6647_Site Plan.pdf 07/28/2025 9756807999e89a1bf6ae3ba642688313__ast5a7a3030a100_spec.pdf 07/28/2025 6fd5208ab3cb25600e2853286a1876d6_denny_app.pdf