4824 Longhouse Trail NE Ste 104_BLD6498_2025
DESIGN CRITERIA DEVICE LEGEND DESIGNED PER IFC - 2021 INSTALLED PER NFPA 72 - 2019 SYMBOL TYPE MANUFACTURER MODEL NOTES MOUNTING COUNT INSTALLED PER NFPA 70 - 2023 Device & Wiring Notes: All device wiring to be Class B configuration and not to exceed maximum distances per wire gauge (16 AWG = 4900 Ft). All audible notification devices to be set to a three pulse temporal pattern. All audible and visual notification devices serving the same area are to be synchronized. SCOPE OF WORK COMMERCIAL ALARM & DETECTION WILL EXPAND EXISTING FIRE CABLE CODES ALARM SYSTEM BY INSTALLING NEW & RELOCATING EXISTING AUDIBLE AND VISIBLE DEVICES. THE EXISTING SYSTEM UTILIZES WIRELESS RADIO TRANSMISSION FOR REMOTE EMERGENCY CODE FUNCTION DESCRIPTION NECTYPE CABLE ROUTING DISPATCH OF FIRE ALARM EMERGENCIES. THIS IS ACCOMPLISHED THROUGH THE USE OF TWO-WAY RADIO SUBSCRIBER UNIT TRANSMITTING ON FREQUENCY 465.9875 MHZ LICENSED TO SECURITAS TECHNOLOGY WITH FCC. THIS UNIT COMMUNICATES TO CENTRAL STATION THROUGH A MINIMUM OF TWO GOOD PATHS WITH A NETCON OF 5 OR LESS. THESE PATHS CAN BE DOCUMENTED UPON REQUEST OR VERIFIED DURING FINAL INSPECTION. NOTES: RAMP UP TO CLOSET N: New device DANCE FLOOR E: Existing device 107 R: Relocate existing device 42" HIGH COMMERCIAL PONY WALL BIG STUDIO ALARM & DETECTION INC. 17199 BENNETT ROAD 106 MT VERNON, WA 98273 LICENSE # COMMEAI948LO 11'-2" RAMP UP TO AREA OF WORK PHONE: (360) 848-1533 DANCE FLOOR APPROVAL SIGNATURE: 42" HIGH PONY WALL E 75 EOL NAME: BERNIE STEBAR N3-9 CERTIFICATION NUMBER: NICET IV #116393 2C EXPIRATION DATE: 4/1/27 REVISIONS NO. DATE REASON FOR REVISION NAC 3 KEY PLAN 2C N N SCALE: NTS STORAGE CLOSET NAC 3 SMALL STUDIO 106 SHEET LIST 105 FLOOR PLAN FA-1 VICINITY MAP RESTROOM 11'-2" DEVICE LEGEND 103 CABLE CODES N 30 R SLC POINT LIST 9'-0" BATTERY CALCULATIONS FA-2 15 LOBBY RISER DIAGRAM NAC 3 N3-7 2C 100 N3-6 2C NAC 3 11'-2" RESTROOM CONTRACT INFORMATION NAC 3 102 BYK Construction 9'-0" PO BOX 619 4C Sedro Woolley, WA 98284 15 N RAMP UP TO PROJECT MANAGER: HALLWAY DANCE FLOOR 95 N Anna Holleman N3-8 PHONE: N3-5 101 (425) 610-5059 11'-2" EMAIL: annah@bykconstruction.com AUTHORITIES HAVING JURISDICTION: EXISTING TENANT City of Arlington and L&I N3-4 NO WORK JOB INFORMATION INNOVATIVE PAC AT OUTPOST E 15 BUILDING 5 4824 Longhouse Trail Lane, Suite 104 Arlington, WA 98284 VICINITY MAP DOCUMENT NAME N N FIRST FLOOR PLAN NN FA-1 SCALE: 3/16" = 1' SCALE: NTS DRAWN BY DATE CHECKED BY M. JENNINGS 05/14/2025 B. STEBAR PAGE NUMBER PAGE SIZE JOB NUMBER 1 OF 2 24 x 18 25-114 DESIGN CRITERIA DESIGNED PER IFC - 2021 INSTALLED PER NFPA 72 - 2019 INSTALLED PER NFPA 70 - 2023 Device & Wiring Notes: All device wiring to be Class B configuration and not to exceed maximum distances per wire gauge (16 AWG = 4900 Ft). All audible notification devices to be set to a three pulse temporal pattern. All audible and visual notification devices serving the same area are to be synchronized. SCOPE OF WORK COMMERCIAL ALARM & DETECTION WILL EXPAND EXISTING FIRE ALARM SYSTEM BY INSTALLING NEW & RELOCATING EXISTING AUDIBLE AND VISIBLE DEVICES. THE EXISTING SYSTEM UTILIZES WIRELESS RADIO TRANSMISSION FOR REMOTE EMERGENCY DISPATCH OF FIRE ALARM EMERGENCIES. THIS IS ACCOMPLISHED THROUGH THE USE OF TWO-WAY RADIO SUBSCRIBER UNIT TRANSMITTING ON FREQUENCY 465.9875 MHZ LICENSED TO SECURITAS TECHNOLOGY WITH FCC. THIS UNIT COMMUNICATES TO CENTRAL STATION THROUGH A MINIMUM OF TWO GOOD PATHS WITH A NETCON OF 5 OR LESS. THESE PATHS CAN BE DOCUMENTED UPON REQUEST OR VERIFIED DURING FINAL INSPECTION. FACP BATTERY & VOLTAGE DROP CALCULATIONS BATTERIES USED: EXISTING (2) 12v-10AH (EXISTING) (EXISTING) AES RADIO COMMERCIAL ALARM & DETECTION INC. SILENT KNIGHT (7707P-88-ULP-M) 17199 BENNETT ROAD MT VERNON, WA 98273 LOCATED BY FACP LICENSE # COMMEAI948LO SK-6808 FACP PHONE: (360) 848-1533 APPROVAL SIGNATURE: J1 RESET SWITCH NAME: Wait-WA BERNIE STEBAR Accessory & Programmer Transmit-TX Recieve-RX Status-ALM CERTIFICATION NUMBER: Port NICET IV #116393 CIRCUIT (EXISTING) DEDICATED 120VAC NAC 4 UNUSED EXPIRATION DATE: J4, Antenna Cut/Trouble 4/1/27 Output NAC 3 7794A 2.0 IntelliPro Form C Relay, Fail Secure REVISIONS Contact Rating: 24vdc, 1a NO. DATE REASON FOR REVISION NAC 2 Resistive NAC 1 Transceiver FIRE ALARM RELAY PHONE LINES SUPERVISORY ALARM RELAY SHEET LIST Z1 G Z2 Z3 G Z4 Z5 G Z6 Z7 G Z8 TROUBLE RELAY FLOOR PLAN FA-1 16.5VAC +BAT- VICINITY MAP DEVICE LEGEND CABLE CODES NOTE: ALL 7707P SLC POINT LIST RELAYS resistors 2.2k Ohm 12V-12AH BATTERY CALCULATIONS FA-2 BATTERY RISER DIAGRAM CONTRACT INFORMATION PHONE LINES BYK Construction PO BOX 619 NOTIFICATION CIRCUITS Sedro Woolley, WA 98284 PROJECT MANAGER: Anna Holleman PHONE: NAC 3 15 75 15 15 15 15 30 95 75 (425) 610-5059 EXISTING EMAIL: N2-1 E N2-2 E N2-3 E N2-4 E N2-5 N N2-6 N N2-7 E N2-8 N N2-9 E (2) 12V-10AH annah@bykconstruction.com BATTERIES WP WP WP WP WP WP AUTHORITIES HAVING JURISDICTION: SLC LOOP 1 DEVICES: NAC 2 95 95 95 75 15 95 City of Arlington and L&I (97:s001-159, 97:m001-159) JOB INFORMATION N2-1 E N2-2 E N2-3 E N2-4 E N2-5 E N2-6 E NOTES: SEE POINT LISTING INNOVATIVE PAC AT OUTPOST WP WP WP WP WP WP BUILDING 5 75 95 95 95 95 95 N: New device 4824 Longhouse Trail Lane, Suite NAC 1 104 N1-1 E N1-2 E N1-3 E N1-4 E N1-5 E N1-6 E E: Existing device Arlington, WA 98284 DOCUMENT NAME FIRE ALARM RISER DETAIL FA-2 DRAWN BY DATE CHECKED BY SCALE: NTS M. JENNINGS 05/14/2025 B. STEBAR PAGE NUMBER PAGE SIZE JOB NUMBER 2 OF 2 24 x 18 25-114 FIRE ALARM PERMIT APPLICATION Community and Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 Type of Permit: ï² New Installation ï² System Modification ï² Phased Installation Property Address: Suite No.: Project Valuation: Lot #: Parcel ID No.: Preferred Contact: ï² Owner ï² Applicant ï²Contractor Project Description: Owner Name: Phone No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Applicant Name: Phone No.: Email Address: Cell No.: Mailing Address: City: State: Zip: Contractor Name: Phone No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation Submit electronic files of the follow: ï² Complete and Scaled Plans ï² Specification Sheets ï² Wiring Diagrams (Point to Point Wiring) ï² Electrical Plans, if applicable NOTE: All Central Station Monitoring must be UL or FM listed. FIRE ALARM SYSTEMS (105.7.3) ** DEVICES include separate individual portions of a Fire Alarm System such as: Initiating Devices, Notification Appliances, Flow Switch, Supervisory Switches, Magnetic Door Hold-Open Devices, Remote Annunciators, Pull Stations, Beam Detectors, and other such devices. (Each piece is one device) PLAN REVIEW FEES - shall be paid at time of application submittal Less than $5,000.00 = $200.00 $5,000.00 & over – based on project valuation (Plan Review Fee is 65% of project valuation per Fee Calculation Table 4-1) REV2022 Page 1 of 2 REINSPECTION / PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application – review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour (1 hour minimum) $75.00 ï² TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 72) Number of Devices** Device Fee Subtotal 1 to 2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ > 200 $500.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices = $500.00 + $ = $ FACP/ TRANSMITTER Modification $125.00 = $ PERMIT FEE SUBTOTAL $ ï² NEW COMMERCIAL SYSTEM (NFPA 72) Number of Devices** Device Fee Subtotal 1 to 100 $350.00 = $ 101 to 200 $475.00 = $ > 200 $500.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices = $500.00 + $ = $ FACP/ TRANSMITTER New $200.00 = $ PERMIT FEE SUBTOTAL $ PERMIT FEE TOTAL $ PLAN REVIEW FEE $ Processing/Technology Fee $25.00 TOTAL $ I hereby certify that I am the Owner, Applicant, Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. Signature Print Name Date REV2.2024 Page 2 of 2 CUT SHEET PACKET FOR Innovative PAC at Outpost Building 5 4824 Longhouse Trail Lane, Suite 104 Arlington, WA 98284 FIRE ALARM SYSTEM Prepared By: COMMERCIAL ALARM & DETECTION, INC. 17199 BENNETT ROAD MOUNT VERNON, WA 98273 360-848-1533 CONTACT: ERIC SIGMEN CUT SHEET PACKET Innovative PAC at Outpost Building 5 HORNSTROBES / STROBES L-Series and L-Series with LED Indoor Selectable Horns, Strobes and Horn Strobes System Sensor L-Series and L-Series with LED audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series and L-Series with LED • LED technology provides lower current draw platform offers the most versatile and easy-to-use line of horns, • Digital Voltage Meter (DVM) diagnostic test points for Horn strobes, and horn strobes in the industry with lower current draw and Strobes and Strobes modern aesthetics. LED lighting technology offers significantly lower • Common aesthetics across the L-Series platform current draw compared to older Xenon bulbs across a full candela • Standard and compact sizes range. This improves design flexibility for notification appliance • Tamper-resistant construction circuits (NACs) while also reducing power supply requirements allowing for simpler and lower cost installations. • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 Flexible design options meet virtually any application requirement: • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, wall or ceiling mount, standard or compact sizes, red or white color 115, 150, and 177 choices, bezel kits for alternate markings and languages, and LED • Rotary switches for candela, tone and volume selections color lenses for distinctive visual signaling. In addition, installers can • Mounting plate provides plug-in design for easier installation and easily adapt devices using field selectable candela, tone and volume shorting springs to check wiring continuity settings using rotary switches. • Electrically compatible with legacy SpectrAlert, SpectrAlert Advance and L-series devices The L-Series and L-Series with LED line is developed to simplify installation. All devices feature plug-in designs with minimal intrusion • Synchronization through use of UL approved power supplies that into the back box, making installations fast and foolproof while support System Sensor Sync protocol or System Sensor MDL3 Sync Module virtually eliminating costly and time-consuming ground faults. The universal mounting plate includes an onboard shorting spring, so • Horns, Strobes and Horn Strobes listed for wall or ceiling use installers can test wiring continuity before the device is installed. In addition, the System Sensor L-Series with LED notification appliances offer a new diagnostic test point feature that allows you Agency Listings to measure device voltage with a digital voltage meter (DVM) without removing the appliance from the wall or ceiling. The DVM test points are discreetly located on the face of the notification appliance which enable faster troubleshooting and end of line (EOL) voltage checks Horn Strobes Horns: Horns: 3057072 7300-1653:0525 while greatly reducing the risk of misplacing or damaging appliances and Strobes: S4011 S4011 FM23FPUS0195 7135-1653:0503 during troubleshooting. S5512, S4011 7135-1653:0526 AVDS916-01 • 10/03/2023 • Page 1 L-Series and L-Series with LED Specifications Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage, LED Strobes and Horn Strobes Regulated 24 VDC Nominal Voltage, Horns Regulated 12 VDC or regulated 24 DC/FWR Operating Voltage Range, LED Strobes and Horn Strobes 16 to 33 V (24 V nominal) Operating Voltage Range, Horns 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG UL/ULC Current Draw Data, Horn Tones, and Sound Output Data UL/ULC Maxmimum Strobe Current Draw (mA) UL/ULC Maxmimum Horn Current Draw (mA RMS) Candela 16–33 Volts 8–17.5 Volts 16–33 Volts Rating Wall Ceiling Sound Pattern dB DC DC FWR Candela 15 18 18 Temporal High 39 44 54 Range 30 22 22 Temporal Low 28 32 54 75 70 70 Non-Temporal High 43 47 54 95 75 75 Non-Temporal Low 29 32 54 110 85 — 3.1 KHz Temporal High 39 41 54 115 — 90 3.1 KHz Temporal Low 29 32 54 135 105 — 3.1 KHz Non-Temporal High 42 43 54 150 — 110 3.1 KHz Non-Temporal Low 28 29 54 177 — 115 Coded High 43 47 54 185 120 — 3.1 KHz Coded High 42 43 54 UL/ULC Maximum Horn Strobe Current Draw (mA) and Sound Output (dBA) Current Draw (mA RMS), Horn Strobe, Sound Candela Range (15-185 cd) Output (dBA) 16-33 Volts 16-33V Switch Volume 15cd 30cd 75cd 95cd 110cd 115cd 135cd 150cd 177cd 185cd DC Pos. Sound Pattern Setting WALL CEILING WALL CEILING CEILING WALL 1 Temporal 3 High 35 38 87 92 94 120 189 189 190 190 87 2 Temporal 3 Low 35 38 87 92 94 120 135 135 145 145 79 3 Non-Temporal High 50 52 87 92 94 120 127 127 135 135 87 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 79 5 3.1KHz Temporal 3 High 35 38 87 89 91 115 155 155 165 165 86 6 3.1KHz Temporal 3 Low 35 38 87 89 91 115 128 130 135 135 80 7 3.1KHz Non-Temporal High 40 42 87 89 91 115 125 125 135 135 86 8 3.1KHz Non-Temporal Low 35 38 87 89 91 115 120 120 130 130 80 AVDS916-01 • 10/03/2023 • Page 2 L-Series with LED Dimensions: Wall-Mounted Equipment 2.07" 3.46" (53 mm) 3.57" 1.55" 3.46" 88 mm 1.25" 88 mm 1.25" 32 mm (9.1 cm) (3.9 cm) (31.8 mm) 5.38" 5.27" 5.27" (13.7 cm) 133.9 mm 133.9 mm A0617-00 A0547-00 A0557-00 Compact Strobe, Horn Strobe Compact Horn Compact Surface Mount Back Box for Wall for Walls (SBBGRL, SBBGWL) 2.07" 4.7" 4.7" (53 mm) 1.25" 119 mm 1.25" 119 mm 4.82" 32 mm 1.85" (31.8 mm) (12.24 cm) (4.69 cm) 5.67" 5.67" 144 mm 5.78" 144 mm (14.68 cm) A0613-00 A0549-00 A0554-01 Strobes, Horn Strobes Horn Surface Mount Back Box for Walls for Walls ( SBBRL/SBBWL) L-Series with LED Dimensions: Ceiling-Mounted Equipment 6.92" diam. 2.5" 2.07" (175.77 mm) (64 mm) (52.6 mm) 6.83" diam. 1.25" (173.5 mm) (31.8 mm) A0608-00 A0546-00 Strobes and Horn Strobes Surface Mount Back Box for Ceilings for Ceilings (SBBCRL, SBCWL) AVDS916-01 • 10/03/2023 • Page 3 L-Series with LED: Ordering Information Model Description Model Description L-Series with LED Horn Strobes LED Lenses P2RLED 2-Wire, Horn Strobe, Wall, Red LENS-A3 Lens LED Amber Wall/Ceiling P2RLED-B 2-Wire, Horn Strobe, Wall, Red, Bilingual LENS-B3 Lens LED Blue Wall/Ceiling P2WLED 2-Wire, Horn Strobe, Wall, White LENS-G3 Lens LED Green Wall/Ceiling P2WLED-B 2-Wire, Horn Strobe, Wall, White, Bilingual LENS-R3 Lens LED Red Wall/Ceiling P2GRLED 2-Wire, Compact Horn Strobe, Wall, Red Accessories P2GRLED-B 2-Wire, Compact Horn Strobe, Wall, Red, Bilingual TR-2 Universal Wall Trim Ring Red P2GWLED 2-Wire, Compact Horn Strobe, Wall, White TR-2W Universal Wall Trim Ring White P2GWLED-B 2-Wire, Compact Horn Strobe, Wall, White, SBBRL Wall Surface Mount Back Box, Red Bilingual SBBWL Wall Surface Mount Back Box, White P2RLED-P 2-Wire, Horn Strobe, Wall, Red, Plain SBBGRL Compact Wall Surface Mount Back Box, Red P2WLED-P 2-Wire, Horn Strobe, Wall, White, Plain SBBGWL Compact Wall Surface Mount Back Box, White P2RLED-SP 2-Wire, Horn Strobe, Wall, Red, FUEGO TRC-2 Universal Ceiling Trim Ring, Red P2WLED-SP 2-Wire, Horn Strobe, Wall, White, FUEGO TRC-2W Universal Ceiling Trim Ring, White PC2RLED 2-Wire, Horn Strobe, Ceiling, Red SBBCRL Ceiling Surface Mount Back Box, Red PC2RLED-B 2-Wire, Horn Strobe, Ceiling, Red, Bilingual SBBCWL Ceiling Surface Mount Back Box, White PC2WLED 2-Wire, Horn Strobe, Ceiling, White Bezels†PC2WLED-B 2-Wire, Horn Strobe, Ceiling, White, Bilingual BZR Wall Red Bezel Kit L-Series with LED Strobes BZW Wall White Bezel Kit SRLED Strobe, Wall, Red BZGR Compact Wall Red Bezel Kit SRLED-B Strobe, Wall, Red, Bilingual BZGW Compact Wall White Bezel Kit SWLED Strobe, Wall, White BZRC Horn Strobe Ceiling Red Bezel Kit SWLED-B Strobe, Wall, White, Bilingual BZWC Horn Strobe Ceiling White Bezel Kit SGRLED Strobe, Compact, Wall, Red SGRLED-B Strobe, Compact, Wall, Red, Bilingual Notes for L-Series With LED Horn Strobes and Strobes: SGWLED Strobe, Compact, Wall, White All -P models have a plain housing (no “FIRE†marking on cover). All -SP models have “FUEGO†marking on cover. SGWLED-B Strobe, Compact, Wall, White, Bilingual All -ALERT models have “ALERT†marking on cover. SRLED-P Strobe, Wall, Red, Plain All -B models have “FIRE/FEU†marking on cover for use in Canadian SWLED-P Strobe, Wall, White, Plain applications. Amber lenses are not for use in Canadian applications SRLED-SP Strobe, Wall, Red, FUEGO SWLED-CLR- Strobe, Wall, White, ALERT Notes for L-Series Horns: ALERT *Horn-only models are listed for wall or ceiling use. SWLED-ALERT Strobe, Wall, White, ALERT, Amber Lens SCRLED Strobe, Ceiling, Red Notes for Bezels: †Each bezel pack ships in a package of 5. SCRLED-B Strobe, Ceiling, Red, Bilingual Add one of the following extensions for print/language options: -F (FIRE), -AL SCRLED-P Strobe, Ceiling, White, Plain (ALERT), -EV (EVAC), -AG (AGENT), -P (Plain), -FR (FEU), -PG (FOGO), -SP SCWLED Strobe, Ceiling, White (FUEGO), -SPE (FUEGO/FIRE). SCWLED-B Strobe, Ceiling, White, Bilingual SCWLED-P Strobe, Ceiling, White, Plain SCWLED-CLR- Strobe, Ceiling, White, ALERT ALERT L-Series Horns HRL* Horn, Red HRLA* Horn, Red, Plain, ULC HWL* Horn, White HWLA* Horn, White, Plain, ULC HGRL* Compact Horn, Red HGRLA* Compact Horn, Red, Plain, ULC HGWL* Compact Horn, White HGWLA* Compact Horn, White, Plain, ULC 3825 Ohio Avenue • St. Charles, IL 60174 USA System Sensor® is a registered trademark of Honeywell International, Inc. Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com 3333 Unity Drive, Mississauga, ON L5L 3S6 Canada ©2023 System Sensor. Phone: 800-SENSOR2 • Fax: 905-812-0771 Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. www.systemsensor.ca AVDS916-01 • 10/03/2023 CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 4824 LONGHOUSE TRAIL LANE NE STE 104 Permit #: 6498 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 31052800100900 DATE OF ISSUANCE. Scope of Work: Expand existing fire alarm system by installing new and relocating Valuation: 4337.00 existing audible and visible devices OWNER APPLICANT CONTRACTOR ARLINGTON 51ST ST LLC Commercial Alarm & Detection, Inc Commercial Alarm & Detection PO BOX 619 17199 Bennett Rd 17199 Bennett Rd SEDRO WOOLLEY, WA 98284 Mount Vernon, WA 98273 Mount Vernon, WA 98273 360-848-1533 3606612630 LIC: COMMEAI948LO EXP: 11/19/2026 LIC: 602 389 969 EXP: 05/31/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC #: EXP: LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE ALARM CODE YEAR: 2021 STORIES: 1 CONST. TYPE: VA DWELLING UNITS: OCC GROUP: B; Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 07/09/2025 Applicant Signature Date Building Official Date CONDITIONS Adhere to the approved plans. Inspection is required. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 07/09/2025 Web Only - Fire System Plan Review $200.00 07/09/2025 Credit Card Service $6.00 07/09/2025 Fire Alarm System Permit $125.00 07/09/2025 Processing/Technology $25.00 07/09/2025 Credit Card Service $4.50 Total Due: $360.50 Total Payment: $360.50 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail Permit #: 6498 Permit Date: 05/14/25 Permit Type: FIRE ALARM Project Name: Innovative PAC at the Outpost Bldg-5 Applicant Name: Commercial Alarm & Detection, Inc Applicant Address: 17199 Bennett Rd Applicant, City, State, Zip: Mount Vernon, WA 98273 Contact: Milo Jennings Phone: 360-848-1533 Email: milo@cfirepro.com Scope of Work: Expand existing fire alarm system by installing new and relocating existing audible and visible devices Valuation: 4337.00 Square Feet: 220 Number of Stories: 1 Construction Type: VA Occupancy Group: B; Business ID Code: Permit Issued: 07/09/2025 Permit Expires: 01/05/2026 Form Permit Type: FIRE ALARM Status: COMPLETE Assigned To: Kristin Foster Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 4824 LONGHOUSE TRAIL LANE ARLINGTON 51ST ST 126 MULTI-FAMILY 31052800100900 BSP NE STE 104 LLC MKT Contractors Contractor Primary Contact Phone Address Contractor Type License License # CONSTRUCTION Commercial Alarm & Detection Eric Sigmen 3606612630 17199 Bennett Rd Labor & Industries COMMEAI948LO CONTRACTOR CONSTRUCTION Commercial Alarm & Detection Eric Sigmen 3606612630 17199 Bennett Rd COA 602 389 969 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status FA00. FIRE ALARM 08/04/2025 Scheduled for 8:30am 08/06/2025 08/06/2025 BUILDING Approved FINAL FA00. FIRE ALARM 08/04/2025 Final OK 08/06/2025 08/06/2025 FIRE Approved FINAL Plan Reviews Date Review Type Description Assigned To Review Status 05/15/2025 FIRE ALARM BUILDING Approved Fees Fee Description Notes Amount Web Only - Fire System Plan Review Enter 1 if permit is for: fire alarm, or fire sprinkler $200.00 Credit Card Service $6.00 Fire Alarm System Permit NFPA 72 - 105.7.3 $125.00 Processing/Technology $25.00 Credit Card Service $4.50 Total $360.50 Attached Letters Date Letter Description 07/09/2025 Building Permit 05/14/2025 Web Form - Building Application Payments Date Paid By Description Payment Type Accepted By Amount 05/14/2025 Alex Skorick 231363051 Hannah Hardwick $6.00 05/14/2025 XBP Conf: 231363051 $200.00 07/03/2025 Alex Skorick 236087842 $4.50 07/03/2025 XBP Conf: 236087842 $150.00 Outstanding Balance $0.00 Notes Date Note Created By: 05/15/2025 Emailed for the application and equipment specs Kristin Foster Uploaded Files Date File Name 07/09/2025 27244467-20250514_BLD6498_ApprovedPlans.pdf 07/09/2025 27244463-20250709_BLD6498_IssuedPermit.pdf 05/15/2025 25972924-20250514_BLD6498_Plans.pdf 05/15/2025 25972923-20250515_BLD6498_Cutsheets.pdf 05/15/2025 25972921-20250515_BLD6498_App.pdf