Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
7725 Kestrel Ct_BLD6559_2025
Submittal TRANE Link Variable Speed Heat Pumps 5TWV0X36A1000A Note: Graphics in this document are for representation only. Actual model may differ in appearance. TM The Diagnostics Mobile App is available by scanning a QR code above, the one located inside this unit or by searching for the Trane or American Standard Diagnostics App in your App Store®. This system must include a A/T HUI2360A200U thermostat and a TSYS2C60A2VVU system controller to operate and is Link communicating only. February 2025 TH03-PRQ001A-EN Outline Drawing ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. SERVICE PANEL LIQUID LINE SERVICE VALVE, “E†I.D. FEMALE BRAZED CONNECTION WITH 1/4†SAE FLARE PRESSURE TAP FITTING. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 (12â€) FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED GAS LINE SERVICE VALVE, “D†I.D. FEMALE BRAZED CONNECTION WITH 1/4†SAE FLARE PRESSURE TAP FITTING. ELECTRICAL SERVICE PANEL 25 (1) 22.2 (7/8) DIA. HOLE LOW VOLTAGE 28.6 (1-1/8) DIA. K.O. WITH 22.2 (7/8) DIA. HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPPLY LIQUID LINE SERVICE VALVE, “E†I.D. FEMALE BRAZE CONNECTION WITH 1/4†SAE FLARE PRESSURE TAP FITTINGS. GAS LINE 1/4 TURN BALL SERVICE K.O. FOR ALTERNATE VALVE, “D†I.D. FEMALE BRAZED CONNECTION ELECTRICAL ROUTING WITH 1/4†SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H J K 1307.0 946 870 143 92 210 79 994.1 5TWV0X36A 4 16-5/8 8-5/16 (51.4) (37-1/4) (34-1/4) (5-5/8) (3-5/8) (8-1/4) (3-1/8) (39.1) SOUND POWER LEVEL Full Octave Sound Power [dB] A-Weighted Sound Model Mode Speed Power Level [dB(A)] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Cool Min 53 63.6 51.2 52.5 51.5 48.2 43.4 34.7 38.3 Cool Max 69 82.2 70.3 68.3 65.6 65.5 58.3 53.3 48.9 5TWV0X36A Heat Min 55 63.8 52.9 55.9 53.4 49.1 44.4 40.4 42.1 Heat Max 74 79.0 77.8 75.0 71.8 69.9 63.3 59.5 53.7 Note:Rated in accordance with AHRI Standard 270–2008. 2 TH03-PRQ001A-EN Product Specifications Heat Pump Models (d) NA means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. OUTDOOR UNIT(a) (b) 5TWV0X36A (e) This value approximate. For more precise value see unit nameplate. (f) The maximum length of refrigerant lines from outdoor to indoor varies POWER CONNS. – V/PH/HZ(c) 208/230/1/60 depending on application. See Installer's Guide Table 4 for allowable applications. MIN. BRCH. CIR. AMPACITY 26 BR. CIR. PROT. RTG. – MAX. (AMPS) 40 Mechanical Specification COMPRESSOR SCROLL Options NO. USED – NO. SPEEDS 1-VARIABLE General MRC 18 This unit is designed to operate at outdoor ambient FACTORY INSTALLED temperatures from 55° F to 120° F in cooling. From — 0° F to 66° F in heating (heat pumps only). Only AHRI approved START COMPONENTS(d) NA indoor matches are approved for use with these models. INSULATION/SOUND BLANKET YES TRANE Link Air Conditioners COMPRESSOR HEAT YES This outdoor unit contains the TRANE Link Air Conditioners OUTDOOR FAN digital communication with Plug-n-Play set up. DIA. (IN.) – NO. USED 27.5-1 Casing TYPE DRIVE – NO. SPEEDS DIRECT-VARIABLE Unit casing is constructed of heavy gauge. G60 galvanized steel and painted with a weather-resistant powder paint on NO. MOTORS – HP 1-1/2 all louvered panels and prepaint on all other panels. MOTOR SPEED R.P.M. 200-1200 Corrosion and weatherproof CMBP-G30 DuraTuffâ„¢ base. VOLTS/PH/HZ 245-385/3/60 WeatherGuardâ„¢II Top Shields Unit. MOC 2.3 Refrigerant Controls OUTDOOR COIL – TYPE SPINE FIN Refrigeration system controls include condenser fan, compressor inverter drive and high and low pressure ROWS – F.P.I. 1-24 switches. A factory supplied, field installed filter is standard. FACE AREA (SQ. FT.) 30.8 Compressor TUBE SIZE (IN.) 3/8 Inverter driven compressor with variable output capacities. Noise enclosure minimizes sound levels. Compressor REFRIGERANT R-454B protections reduce operating speed and current draw to LBS. – R-454B (O.D. UNIT)(e) 9 LB-8 OZ maintain operation while protecting the compressor. FACTORY SUPPLIED YES Condenser Coil RATED LINE SIZE – IN. O.D. GAS(f) 5/8 The Spine Finâ„¢ outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected RATED LINE SIZE — IN. O.D. LIQ. 5/16 on all four sides by louvered panels. CHARGING SPECIFICATIONS SeaCoast Shield. SUBCOOLING 8° Low Ambient Cooling DIMENSIONS As manufactured, this system has built in freeze protection CRATED (IN.) 55 x 35 x 38 that will allow cooling operation below 55°F but will reduce capacity or shut down completely to prevent operation WEIGHT under adverse conditions. SHIPPING (LBS.) 248 Comfort Control NET (LBS.) 222 This system must include a A/T HUI2360A200U thermostat (a) Certified in accordance with the Air-Source Unitary Air-conditioner Equipment and a TSYS2C60A2VVU system controller to operate and certification program, which is based on AHRI standard 210/240. is Link communicating only. (b) Rated in accordance with AHRI standard 270/275. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. TH03-PRQ001A-EN 3 Trane - by Trane Technologies (NYSE: TT), a global innovator - creates comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane.com or tranetechnologies.com. The AHRI Certified mark indicates Trane U.S. Inc. participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org. Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. TH03-PRQ001A-EN 12 Feb 2025 Supersedes (New) ©2025 Trane Permit #: 6559 Permit Date: 06/16/25 Permit Type: RESIDENTIAL MECHANICAL Project Name: Mechanical - Al Mattus Applicant Name: Lifetime Heating & Cooling Applicant Address: 2801 Bickford Ave, Suite 103 - PMB 148 Applicant, City, State, Zip: Snohomish Contact: Renee Visitacion Phone: 4255534328 Email: reneev@lifetimeheating.com Scope of Work: Lifetime to install heat pump on left side of home 8ft from property line Valuation: 17155.60 Square Feet: 2 Number of Stories: 1980 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 06/16/2025 Permit Expires: 12/15/2025 Form Permit Type: RESIDENTIAL MECHANICAL Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel # Address Legal Description Owner Name Owner Phone Zoning MATTUS ALFREDO & 100 SINGLE FAMILY 00809200002600 7725 KESTREL CRT CECILIA RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License # Lifetime Heating & Air 2801 Bickford Avenue, CONSTRUCTION Valura Brashears 425-553-4328 COA 604 054 968 Conditioning Suite 103 CONTRACTOR Lifetime Heating & Air 2801 Bickford Avenue, CONSTRUCTION Valura Brashears 425-553-4328 Labor and Industries LIFETHA820L8 Conditioning Suite 103 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status R15. MECHANICAL 08/07/2025 08/08/2025 08/08/2025 BUILDING Approved FINAL Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Heat Pump - Condensing Unit Enter # of units $25.00 Mechanical Base Permit Fee $25.00 Credit Card Service $4.50 Total $154.50 Attached Letters Date Letter Description 06/16/2025 Building Permit 06/16/2025 Web Form- Residential Mechanical Application Payments Date Paid By Description Payment Type Accepted By Amount 06/16/2025 Darrick Philp 234372337 Hannah Hardwick $4.50 06/16/2025 XBP Conf: 234372337 $150.00 Outstanding Balance $0.00 Uploaded Files Date File Name 06/16/2025 26907310-2025_BLD6559_IssuedPermit.pdf 06/16/2025 3aac02536e94cfa825d6634c9c8a5c78_thp_5twv0x36a1000a_submittal.pdf 06/16/2025 84da70437a2399f08125f13a86fe12c5_site_plan_mattus.pdf 06/16/2025 a03ad8303d8e677c1739ce6906909fe0_al_mattus.pdf