Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
7710 E Country Club Dr_BLD2839_2025
CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:7710 E.Country Club Dr Permit#:2839 Parcel#:00809200004300 Valuation: 00 OWNER APPLICANT CONTRACTOR Name:LUNDBERG DAVID R&SHARON R Name:CM Heating Name:CM Heating Inc Address:7710 E COUNTRY CLUB DR Address:1415 Broadway Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223-5958 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 LIC: EXP: MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address: 1415 Broadway Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone: LIC#:CMHEANM877DN EXP: 03/15/2021 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED, IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded C" ofArling nn N3It� ,/^/� 10/10/19 w�,�rJ i .�/�"�rJ .��(yJ /v`ll Kailana Moniz 10/10/19 Signature 47 Print Name Date Releae By Date CONDITIONS 3" Concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated;use of adhesive tapes are prohibited. Adhere to approved appliance. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/10/2019 Furnace $25.00 10/10/2019 Heat Pump $25.00 10/10/2019 Mechanical Permit Base Fee $25.00 10/10/2019 Processing/Technology Fee $25.00 Total Due: $100.00 Total Payment: $0 00 Balance Due: $100.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 2839 Permit Date: 10/10/19 Project Name: Lundberg Site Address: 7710 E. Country Club Dr Company Name: CM Heating Company Address: 1415 Broadway City, State,Zip: Everett,WA 98201 Contact: Kailana Moniz Phone: 425-259=0550 Email: kailana@cmheating.com Permit Type: Residential Mechanical Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Type of Construction: Occupancy Type: Proposed Use: Gas furnace change out w/HP Install MIC/Opportunity Zone: Permit Issued: Permit Expires: Type of Construction-DNU: Status-DNU: Status: IN PROCESS Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 7710 E COUNTRY CLUB LUNDBERG I I I Single Family 00809200004300 DR DAVID R& Residence- SHARON R Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM Heating Inc Debbie Bauers 425-259-0550 1415 Broadway MECHANICAL Labor& CMHEAMH877DN CONTRACTOR Industries Fees Fee Description Notes Amount Furnace 322.10.00.00 $25.00 Heat Pump 322.10.00.00 $25.00 Mechanical Permit Base Fee 322.10.00.00 $25.00 Processing/Technology Fee 341.43.00.02 $25.00 Total $100.00 Al RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:7710 EASTCOUNTRY CLUB DR Project Description:LIKE IN KIND GAS FURNACE CHANGE OUT WITH HEAT PUMP INSTALLATION Owner: DAVE LUNDBERG Address: 7710 EAST COUNTRY CLUB DR City:ARLINGTON StateWA Zip Code: 98223 Phone: 425-876-9532 Email:davidlundberg53@gmail.com Applicant: KAILANA MONIZ Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 Phone: 425-259-0550 Email: KAILANA@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:CM HEATING Address: 1415 BROADWAY City: EVERETr State WA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration: 05/03/21 Phone:425-259-0550 Email:KAILANA@CMHEATING.COM STAFF USE Y Received Permit #: �j�l� �� Accepted Date: OCT 08 2019 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL • A PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES [� Furnace (80+) Model #S8B1A040M3PSAA AFUE80 Heat Pump Model #4A6H5024H1000A AFUE HSPE10 ❑ AC Unit Model # SEER L-11 Freestanding Stove Uj Fire Place insert Lj Outdoor BBO ❑ Gas Piping U Solid-Fuel Appliance [ lI Other Gas Piping Information Not Applicable: 41 Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to Ue supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date 10/08/2019 Applicant Printed Name: KAILANA MONIZ I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 Amm?wo S*odard. SPLIT SYSTEM HEAT PUMP HEATING & AIR CONDITIONING 1 1/2 - 5 TON III III II III III I IIIIIIIIIII � IIIIIIIII III IIIIII __ I . Illlli'jljl"III III�IIII IIIIIIIIIIII ____. __ HERITAGES 15 MODELS 4A6H5 Received OCT 08 2019 A*sffew S*4Advd $I(AIIHG ♦ AI. CONOIIIONING Features and Benefits • DURATIONTM compressor • Liquid line filter/drier • Efficiency up to 17.0 SEER and • Spinnaker gray cabinet with high 9.0 HSPF contrast badge and cap • All aluminum SPINE FINTM coil • High pressure switch • WEATHERGUARDTM fasteners - Demand Defrust with Diaynustics • EASY-SESSTM cabinet, Service valve cover service access and refrigerant R-410A refrigerant connections with full coil S.E.E.T.design testing protection 100%line run test • DURABASETM base,fast Low ambient cooling to 20oF with complete drain,weatherproof AY28XO84 • COMFORT RTA° mode approved • Low ambient cooling to 55"F as • Glossy corrosion resistant finish shipped • Internal compressor high/low pressure&temperature protection • Extended warranties available • 018-036&061 ship with start kit • Compressor Sump Heat 0 2012-American Standard Heating&Air Conditioning 2 12-1256-16 ,9koffe."ShuA*rd I[wTINp ♦ w111 CONOI TIONINp Contents Features and Benefits 2 General Data 4 Product Specifications 4 A-weighted Sound Power Level [dB(A)] 4 Accessory Description and Usage 6 AHRI Standard Capacity Rating Conditions 6 Model Nomenclature 7 Electrical Data 8 Dimensions 15 Mechanical Specification Options 16 12-1256-16 3 ,9�cenew Shwdwd "[^TING a AIM CONDITIONING General Data Product Specifications Model No.O 4A6H5018G1 4A6H5024G1 4A6H5030G1 4A61-15036131 Electrical Data V/Ph/Hz® 208I230/1/60 208/230/1/60 208/230/1I60 208/230/1/60 Min Cir Ampacity 9 11 15 18 Max Fuse Size(Amps) 15 15 25 30 Compressors DURATION''" DUHAIION'm DURATION'^" DURATION'm RLAMPS-LRAMPS 6.4-38.6 8.3-58 11.3-68.2 13.2-63 Outdoor Fan FL Amps 0.70 0.74 0.74 1.00 Fan HP 1/8 1/8 1/5 1/5 Fan Dia(inches) 23 23 27.5 27.5 Coil Spine Fin TIA Spine Fin TM Spine Fin TM Spine Fin TM Rehigelalll R-410A 5/14-LBIOZ 7IO2-LBIOZ 8/02-LB/OZ 7/13-LB/OZ Line Size-(in.)O.D.Gas O 5/8 5/8 3/4 3/4 Line Size-(in.)O.D.Liquid® 3/8 3/8 3/8 3/8 Dimensions H x W x D(Crated) 34 x 30.1 x 33 38 x 30.1 x 33 38.4 x 35.1 x 38.7 37.9 x 35 x 37.9 Weight-Shipping 204 236 273 261 Weight-Net 176 208 239 227 Start Components YES YES YES YES Sound Enclosure YES YES YES YES Compressor Sump Heat YES YES YES YES Optional Accessories: Anti-short Cycle Timer TAYASCT501 A TAYASCT501 A TAYASCT501 A TAYASCT501 A Evaporator Defrost Control A/C AY28XO84 AY20XO84 AY20XO84 AY28XO84 Rtlhher Isolator Kit RAYISI T101 BAYISLT101 BAYISLT101 BAYISLT101 Hard Start Kit Scroll Extreme Condition Mounting Kit BAYECMT004 BAYECMT004 BAYECMT004 BAYECMT004 Snow Leg-Base&Cap 4"High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg-4"Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Refrigerant Lineset O TAYREFLN950 TAYREFLN950 TAYREFLN7* TAYREFLN7* 0 Certified in accordance with the Air source Unitary I leaf rump Equipment certification program which is based on AHRI Standard 2101240. ®Calculated in accordance with N.E.C.Only use HACK circuit breakers or fuses. O Standard line lengths-80'.Standard lilt-60'Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pubic 32-3312-01.(Idenotes latest revision) O For accessory description and usage,see page 5. O'=15,20,25,30,40 and 50 foot lineset available. A-weighted Sound Power Level[dB(A)] MODEL SOUND POWER A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB-[dB(A)] High Stage LEVEL[dB(A)] 63 125 250 500 1000 2000 4000 8000 4A6H5018G 75 52.3 57.8 62.4 67.2 69.4 67.2 59.6 52.5 4A6H5024G 75 50.3 55 58.6 65.3 69.5 64.5 58.6 50.8 4A6H5030G 75 48.8 55.4 60.1 66.4 67.4 63.9 60.2 53.5 4A6H5036G 75 54.5 55.1 58.3 67 69.8 65.9 59.7 49.1 4A6H5042G 75 55.1 52 59.3 64.9 67.2 63.5 60.4 47.6 4A6H5049E 75 43.7 51.2 54.5 61 61.5 57.1 51.3 40.7 4A6H5061 E 75 33.1 56.2 1 60.1 64.4 66 59.5 54.2 43.5 Note: Rated in accordance with AHRI Standard 270-2008. 4 12-1256-16 A*oi reaa ShWdud HEATING { AIR CONDITIONING General Data Product Specifications Model No.O 4A6H5042G1 4A6H5049E1 4A6H5061E1 Electrical DataWPh/Hz® 208/230/1/60 208/230/1/60 208/230/1/60 Min Cir Ampacity 23 28 36 Max Fuse Size(Amps) 40 50 60 Compressors DURATION'"' SCROLL DURATION'"" SCROLL DURATION TM SCROLL RL AMPS-LR AMPS 16.7-112 21.8-117 26.4-134 Outdoor Fan FL Amps 0.74 1.00 2.80 Fan HP 1/8 1/5 1/3 Fan Dia(inches) 26.6 27.6 27.6 Coil Spine Fin TM Spine Fin TM Spine Fin TM Refrigerant R-410A 9/14-LB/OZ 13/10-LB/OZ 13/12-LB/OZ Line Size-(in.)O.D.Gas O 3/4 7/8 1-1/8 Line Size-(in.)O.D.Liquid O 3/8 3/8 3/8 Dimensions H x W x D(Crated) 4205.108.7 51 x 35.1 x 38.7 51 x 35.1 x 38.7 Weight-Shipping 277 331 332 Weight-Net 243 294 295 Start Components NO NO YES Sound Enclosure YES NO NO Compressor Sump Heat YES YES YES Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control A/C AY28XO84 AY28XO84 AY28XO84 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Crankcase Heater BAYCCHT300A Hard Start Kit Scroll BAYKSKT263 BAYKSKT263 Extreme Condition Mounting Kit BAYECMT004 BAYECMT004 BAYECMT004 Snow Leg-Base&Cap 4"High BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg-4"Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Refrigerant Lineset© TAYREFLN7* TAYREFLN3* TAYREFLN3* D Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240. ®Calculated in accordance with N.E.C.Only use HACR circuit breakers or fuses. O Standard line lengths-60'.Standard lift-60'Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub#32-3312-0t.(tdenotes latest revision) ©For accessory description and usage,see page 5. ©'=15,20,25,30,40 and 50 foot lineset available. 12-1256-16 5 ANcuiw Shwdard ..(.TING \ _11I117I:1,1Nis General Data Accessory Description and Usage AHRI Standard Capacity Rating Conditions Anti-Short Cycle Timer—Solid state timing device that AHRI STANDARD 210/240 RATING CONDITIONS— prevents compressor recycling until 5 minutes have elapsed (A) Cooling 80GF DB,67°F WB air entering indoor coil, after satisfying call or power interruptions.Use in area with 95°F DB air entering outdoor coil. questionable power delivery,commercial applications,long AHRI STANDARD 270 RATING CONDITIONS—(Noise lineset,etc. rating numbers are determined with the unit in cooling opera- Evaporator Defrost Control—SPST Temperature actuated tion.)Standard Noise Rating number is at 95°F outdoor air. switch that cycles the condenser off as indoor coil reaches freeze-up conditions.Used for low ambient cooling to 30OF with TXV. Rubber IaVlatVla—5lalge IULjU l dVI1l1 Lj to IjVlate UU11- densing unit from transmitting energy into mounting frame or pad.Use un any application where sound transmission needs to be minimized. Hard Start kit—Start capacitor and relay to assist compres- sor motor startiip.I Isa in areas with marginal power supply, 0%RAW on long linesets,low ambient conditions,etc. Extreme Condition Mount Kit—Bracket kits to securely C us mount condensing unit to a frame or pad without removing 1,,.r,r any panels.Use in areas with high winds,or on Commercial ruuI[UPS,etc. Intertek 12-1256.16 74*w?,"SAwd"d NtArING a AIA CO-NDITIONING Model Nomenclature 4 A 6 H 5 0 3 6 G 1 0 0 0 A A Gas Furnaces AU D 2 0 0 8 0 A C V 3 2 AA Outdoor Units 71 Furnace Configuration Refrigerant Type AU=Upflown-fo"zonral 2=R-22 AD=Downflow/Horizontal 4=R-410A Typs American Standard E=80%Induced Draft Standard D=80%Induced Draft Premium Product Type C=90%Condensing Standard 6=Sphl Heat Pump X=90%Condensing Premium 7-Split Cooling H=95%Condensing Premium Product Family Number of Heating Stages Z=LeadershipTwo Stage 1=Single Stage - 9 2=Two Stage H-Heritage(heat pump) 3=Three Stage A=Allegiance(cooling) B=Basic Cabinet Width 5"Cabinet Width C=Light Commercial 11=17 5 Cabinet Width Family SEER C=21.0"Cabinet Width 0-10 3-13 6-16 D=24.5"Cabinet Width 1=11 4=14 8=18 Heating Inppu 2=12 5=15 9=19 080.80,000 MBTUH Split System Connections 1-6 Tons Major Design Change 0=Brazed Vbhsp e Nominal Capacity in 000s o1 BTUs 9.115 Vohs 160 Hertz/Natural Gas A.115 Volts/50 Hertz/Natural Gas Major Design Modifications C=115 Volts/Natural Gas with Communicating System Control Power Supply F=115 Volts/Natural Gas with Intograted Electronic Filter 1=200.230/U60 or 208-230/1/60 D=115 Vohs/Natural Gas with Communicating System Control and 3=200-230/3/60 Integrated Electronic Filter 4=460/3/60 Air Capacity for Cooling 36.3 Ton Standard PS C Motor Secondary Function H3=3 Ton High Efficiency Motor Minor Design Modifications — V3=3 Ton Variable Speed Motor Unit Paris Identifier Draft Inducer Speeds 1-Single Speed 2=Tyro Speed V=vanablo Speed Minor Design Change Service Digit-Not Ordarable- 4 T E E 3 F 3 6 A 1 0 0 0 A A Air Handlers- Residential Coils- 4 T X C B 0 o t C C A 14 _C__A_ Refrigerant Type Residential 4- 41 4=R-410A Refrigerant Type R4f OA Appllcetfon TE-Fully Camrerlible Product Family TG=Semi Convertible T-Premium TF=Front Return (Heat Pump or Convertible Coil) Coll Design Product Family X-Direct Expansion Evaporator Coil E-Leadership-Variable Speed Product Family P=Leadership C-Cased A Coil C=ReplaeementlRelail A-Uncased A Coil B=Basic F-Cased Horizontal Flat Coil Flow Control Coll W idth(Cosed/Uncased) 0-No Flow Control A-B-17.14.5 5"/13.3" "/16.3" 3=Nonbleed TXV C-21.0"/19.8" Feature Identifier D-24.5"/23.3" 0=Standard Unit H-10.5" F=Air-Titer^' Refrigerant Line Coupling Nominal Capacity In 1000's(BTUH) 0-Brazed Major Design Change Model Number Dlmin gwsbw Power Supply Major Design Change 1=Single Phase Efficiency C•Slandard Electrical Connection S-Hi Ftfiaeney(Derived fro, 0-PlgCircuit Tails RefrfgerantControl B=Circuit Breaker 3-TXV-Non-Blood D=Pull Disconnect Future Option-Facto Installed Heater Nominal KW Value Call CIr Itry Pt Factory H-Heat ump Minor Design Modifications AlrfIow Con�ilgurstlon Unit Parts Identifier A-UpIlm Only NOTE:There will be a phase-in of new model numbers for new U•UPIlow/Downflow P H•Hon rontal Only ax handlers over next 2 years. C•Convortiole• ypllow,Downflow,Lett or Right Airflow Minor Design Change Unit Parts Identifier -- 12-1256-16 7 r¢�renca� dud Ii[AIING ♦ AIR CON OIt10 NIHc Electrical Data Schematic Diagrams 4A6H5018 TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES i W r-----.� L----- CA COOLING AWI IC IPATOR LPCO LOW PA[SSURE COIDUT SN, SUMP HTR BO!IO S[e1 OD ,BOOR F .ICI11 c,,,N•Ac•D cis iu uv♦ura oDA DUIDOOR AMnuPATOR W 3 TDR 1 .- TDL CN NIA[CONNECTOR Orr OUt DOOR fA1 IXEANOSTAT BR/RD W4 p.BLACK+^/�/�/`��BLACR PURPLE INN'PURPLEIWH CPR COp1R[SSOA OOS OUI DOOR I(pPEAA1 URE SENSOR cq pp1[N APA111 T ppp1 IN[RMD i T C$ m ES S1AR !MU CA AC I TOA S R[S ANCC XEA HITCH CSR CAPACITOR SYIICHIMG A[l At SC SWI ICHOY[$VALVE SOLENOID 'MS I CSR I CSR MS 2m Drt D(flou co$110L SIR SISILM-01.0ff'SNITCH �No y Yf cr 8q I 2 (T�BAIBL r INDOOR FAN RELAY IDL 01111111E LINE IHEANOSTAT AD OR NA X(AIIMG A11111PATOR IN$ IRA.SIORMIR CAPAC I TOR xtlo HIGH Pq[SSURE CUTOUT$W. i$ H[A1I1G C00 IMG THERMOSTAT IOL INI(NNAL OVERLOAD PROTECTOR TSH II(ArIMG In[AMOS TAI (1 BROWN �—( — OR C Avel FOR TIME DEL AI Ail Ar FAN . C N CPR IOU \pL tU0.tLI AO J Q WARNING Q CAUTION BLACK HAZARDOUS VOLTAGE! USE CO►P[R CONDUCTORS ONLY! SKBL DISCONNECT ALL ELECTRIC POWER OMIT TERMINALS ARE NOT DESIGNED NZ ^� INCLUDING REMOTE DISCONNECT$ TO ACCEPT OTHER TYPE$Or DFC LED LLL���N—rL CBS B[FOAC 1[AYICI MG CONDUCTORS. GR CS W.C. CON rl FAILURE TO DISCONNECTPOWER FAILURE TO DO O MAY RI BEFORE SERY ICING CAN CAC S CAUSE CADS[ DAMAGE TO THE EOUIPN[NT! Bq SEVERE PERSONAL INJURY OR DEATH! I ! OW ODS-B �COLOR OF WIRE 8 �1 TI I(' TO r I T L r0 BK/BL BLACK WIRE WITH BLUE MARKER O— F'�'}t'� �`F �•' -COLOR Oi MARKER J LL 1 1 I ON BLACK OR ORANGE YL YELLOW SC 0 BL BLUE RO RED OR GREEN o BL-0jV6OR OR-0- - -1 BR BROWN Wx WHITE PR PURPLE TTHCAL TYPIC AI LPCO I F AIR XAMOLEN I—THERMOSIAT HPCID L� a NOTES r(LION r- -I -I- I IF ODT-B IS NOT USED. ADD JUMPER BETWEEN N2 a 13 WXINO —' AT AIR HANDLER. gEAT[R I IF USED,OUT•0 MUST BE MOUNTED REMOTE OF CONTROL { - LOMS16LSi I I ' BON IN AM APPROVED WEATHER PROOF INC LOSURE. MJ ^t Oq ! ! 2 .T OD*-A !c NOT:ER,ADD JUMPER BETWEEN W! !W2 LrL-L9 0 A , I LJ� A7 AIR HANDLER. v 3 LON VOLTAGE (24 V I FIELD WIRING MUST BE 18 ANG LAINRO MOLE$ ODTB 1,REIgtfL'I, I I I' �I III FOR CANADIAN INSTALLATIONS .fez o-z—e1 z N2 I r r� I POUR INSTALLATIONS CANADIENNES A BM—�—k I I I 'A TI N NOT SUITABLE FOR USE ON YSTC M� CxCCC DING I,OV TO GROUND. (OPTIONAL ATTENTIONS NE DE PLU NT 1 AUx o—z—eN z I I I ( INSTALLATIONS DE PLUS DE I50 V A A BA It - LA TERRE 21 qD YI-�-O TO POWER SUPPLY PER LOCAL CODES J Printed from D156994PO2 6 12-1256-16 jfl* eaf S*ffdvd i*LATING A AIA CONDITIONING Electrical Data Schematic Diagrams 4A6H5024 TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES n ------ CA COOLING ANTICIPATOR LPCO LOW PRESSURE CUTOUT SW CBS COIL BOTTOM SENSOR MS COMPRESSOR MOTOR CONTACTOR 1 SUMP NTR CF FAN CAPACITOR ODA OUTDOOR ANTICIPATOR 3 TDR I ••—-- TDL CN WIRE CONNECTOR 0" OUTDOOR FAM THE RM051A1 BRIRD C>•BLACK+�/�/�/�♦�BLACK��PURPL E INN�PURPLEIWH CPR COMPRESSOR ODS OUTDOOR TEMPERATURE SENSOR n CH RUN CAPACITOR DDT OUTDOOR THERMOSTAT e C$ C5 STARTING CAPACITOR RNS RES ISIAMCE HEAT SWITCH CSR CAPACITOR SWITCHING RELAY SC SWI7CNOYEA YALYE SOLENOID �M$-) C$R•I C$A MS-2"' DFC DEFROST CONTROL SC SYSTEM'0p•OFF'SWITCH 1 p I F INDOOR FAN RELAY TDL DISCHARGE LINE THERMOSTAT �RD OKI 2 S eAlel NA NEATI NG ANTICIPATOR TNS TRANSFORMER HPCO HIGH PRESSURE CUTOUT SW. TS HEAl:NG-COOLING THERMOSTAT T CAPAC IT_OR la INTERNAL OVERLOAD PROTECTOR TSH HEATING THERMOSTAT I > C TOR TIME DELAY RELAY A O IROWK OA exfel FA C H N =CPIOL FA- POWPI( AO ..J WARNING A CAUTION BLACK HAZARDOUS VOL IAGE! USE COPPER CONDUCTORS ONLY! eAIR DISCONNECT ALL ELECTRIC POKER UNIT IERNINALS ARE NOT DESIGNED —'' —'' INCLUDING REMOTE DISCONNECTS 10 ACCEPT OTHER TYPES OF �FC LED AZ "_ CBS BEFORE SERVICING, CONDUCTORS Gp N.C. COM YL FAILURE TO DISCONNECT POWER FAILURE TO DO SO MAY CAUSE xl BEFORE SERVICING CAN CAUSE DAMAGE TO THE EOOIPMENT! eA SEVERE PERSONAL INJURY OR DEATH! ex ODS-B COLOR OF WIRE • R TI 0 T• t A YO BK/BL OL A C K WIRE WITH BLUE MARKER '� L COLOR OF MARKER ON BLACK OR ORANGE YL YELLOW & 7E SC 0 e a BL BLUE RD RED GR GREEN Bl-Q��—OR OA-0- - , BR BROWN WH WHITE PR PURPLE TYIICAL TTPICAI LPCO I I— All RINDLER� I—THERMOSTAT N PCO I�-s_--- -O NDIE5: -I- � � i[IIOW _ _�_...© I. IF ODT-B IS NOT USED. ADD JUMPER BETWEEN W2 R 53 _ AT AIR HANDLER WHIND pfATCR IF USED ODT-B MUST BE MOUNTED REMOTE OF CONTROL - - COMTROISI I I I 2 BOAODT.ANI 5PNOTYUSED.AADDRJUMPER BETWEENRE. WI R W2 M rT•i0A 8 -- A ,. ;__ At AIR HANDLER. Yl-•LO 4r. 3- LOW VOLTAGE 124 V M FIELD WIRING MUST BE 18 AVG MIN INDTE3 ODT•B IOP�IO%At1j b I I ' — : FOR CANADIAN INSTALLATIONS 192 ro� titNOi x ©----r—r-0 I POUR INSTALLATIONS CANADIENNES x ,,,�-x E I I W : NOT SUITABLE FOR USE ON SA EXCEEDING 15OV-TO-GROUND. ODT-A IOPTIONALI ON: NE CONVIENT PAS AUX r•O��A-6II x I I I I ATIONS DE PLUS DE 150 V A � xE. e _I _-- el—�— as F A 11 70 POWER SUPPLY�C . PER LOCAL CODES ••J L_ Printed from DI56994PO2 12-1256-16 9 A*ikeav SAwd"d I!LATING A AIM CONDITIONING Electrical Data Schematic Diagrams 4A6H5030 TO POSER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES 1 r L------ CA COOLING ANTICIPATOR LPCO LON PRESSURE CUTOUT SS 1 ili SUMP '.IT' CBS COIL BOTTON SENSOR MS COMPRESSOR MOTOR CONTACTOR _ L` Cr FAN CAPACITOR ODA OUTDOOR ANTICIPATOR TDL CN TIRE CONNECTOR OFT OUTDOOR FAN THEAMDSTAT BR/R0o-BLACK�M�/�S►�BLACK PURPLE/SN PURPLE/Sp CPA COMPRESSOR ODS OUTDOOR TEMPERATURE SENSOR o CR RUM CAPACITOR DDT OUTDOOR TIICRMOSTAT CS •"TING CAPACITOR RNS RESISTANCE NEAT SWITCH CSR CAPACITOR SNITCHING RELAY SC SWITCHOYER VALV[SOLENOID N_S I CSR•I CSR NS-Z'a DFC DEFROST CONTROL SN SfSTCM'Oq-OFf'StI1CX Q--I RD /R I t Bq/BL F INDOOR FAN RE LAY TDL DISCHARGE LINE THERMOSTAT NA HEATING ANTICIPATOR TNS TRANSFORMER CAPACIi-10 a _ . XPCO SIGN PRESSURE CUTOUT ST. IS HHEIAITINNG-COOLL INNG THERMOSTAT .. .. ' IOL INTERNAL OVERLOAD PAOIECTON TSB NAEIDYtITiiERMi�iAT /0 D Boon w BultFAN 1 R CPR10L .C^ M1.OT R L►nuI r I J Q SARMIMG Q CAUTION $LAC* HA2ARDOU5 VOLTAGE! USE COPPER CONDUCTORS ONLY! BN/Bl DISCONNECT ALL ELECTRIC POKR UNIT TERMINALS ARE NOT DESIGNED /^'� INCLUDING REMOTE DISCONNECTS TO ACCEPT OTHER TYPES Of F LED u TL �+CBS BCfORC SERVICING CONDUCTORS GR 17 M.C. COM YL FAILURE TO DISCONNECT POSER I FAILURE 10 DO 50 MAY CAUSE 1I BEFORE SERVICING CAN CAUSE ORNAGE TO THE EOUIPMENT! xl Rx SEVERE PERSONAL CAN OR DEATHb CO!" of WIRE 0 TI Y ro —1— ES65L OL ACM WIRE WITH BLUE MARKER -Q- L COLOR OF MARKER = BK BLACK OR ORANGE YL YELLOW SC 0 a BL BLUE RD RED GR GREEN BL 00-0- - -, " A " BR BROWN NN WHITE PR PURPLE I 7TT►ICA( TIP I(Al LPCO I AIA HANDLER THE RHOS1Al n T NOTES: $ VLLLON Y- ----re I, If ODT-B 15 NOT USED,ADD JUMPER BETTE EN W2 1 N3 AT AIR HANDLER. NN/RD 'p[gTlq IF USED,ODT-B MUST BE MOUNTED REMOTE OF CONTROL - I I I I 10' IN AM APPROVED RATHER PROOF ENCLOSURE t COXTAq S F OOT-A IS NOT USED. ADO JUMPER BETWEEN■I R W2 T B A 1 e. AT AIR HANDLER. • 1 I--- ----:--- 6�_� L 3. LOS VOLTAGE IN Y F FIELD MIRING MUST BE IB ASG MIN. r 112 oDT•B-IOIIIOIIAIII l i l —� G I FOR CANADIAN INSTALLATIONS O T (R[MDT[1 I ova x—BN— x xt I I 0 -0 POUR INSTALLATIONS CANADIENNES L q F' Bq -' I N: NOT S I NG 1 E FOR USE ON SYS FXC.iFDINC, 150Y TO-f.ReONq ODT-A IOPn ONALT T TI NE CDNVIENT PAS AU% rO�C>—x—Bx x I I I I LA TERRA,IONS DE PLUS DE 150 V A x F' DR x R0� 1W5R iA Yl-i-o TO POSER SS CODES — PER LOCAL COUFS „�� T _.J � _ _. J Printed from D156994PO2 10 12-1256-16 AwWwo Silmdud uEATING A Ala CONDITIONING. Electrical Data Schematic Diagrams (SEE LEGEND) 4A6H5036 10 POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES 1 J I-AA----- CA COOLING ANTICIPATOR LPCO LON PRESSURE CUTOUT SS p CBS COIL BOTTOM SENSOR MS COMPRESSOR MOTOR CONTACTOR SUMP HTR_ CF FAN CAPACITOR ODA OUTDOOR ANTICIPATOR j TOR I ••—•• TDL CN WIRE CONNECTOR Oii OUTDOOR FAN IREFUND TAI BRIRD�o—BLACK+*��P-BLACK�PWNRE/NM PURPLEIVH CPR COMPRESSOR 00DS OUTDOOR TEMPERATURE SENSOR c ` CR RUN CAPACITOR DDT OUTDOOR THERMOSTAT J CS is CS STARTING CAPACITOR FINS RE IS7ANCE H[AT SNITCH CS R CAPAC ROR$NI TCHI MG RELAY SC S211CHOYER VALVE SOLENOID ISMS-I CSR•I CSR M$'2 m DFC DEFROST CONTROL SM S1S7EN'0:.OFF'SNITCH 1 ` " F INDOOR FAN RELAY iDl DISCHARGE LIIE THERMOSTAT b iI�ID�,ylw.ea eNleL 2 HA HEATING ANTICIPATOR INS TAANSFOAMER T RD CAPACITOR OII ., NPCO HIGH PRESSURE CUTOUT SN, IS HEATING-COOLING THERMOSTAT IO. INTERNAL OVERLOAD PpOTEC70R ISH HEATING THERMOSTAT I ' < TOR TIME DELAY RELAY /0.p BROWN aN eN/eL FAN 1 C N 1 CPR IOL r MTR� �« v0vu Ro J Q NARKING Q CAUTION BLACK HAZARDOUS VOLTAGE! USE COPPER CONDUCTORS ONLY! BR/Bl DISCONNECT ALL ELECTRIC POWER UNIT TERMINALS ARE NOT DESIGNED /� INCLUDING REMOTE DISCONNECTS TO ACCEPT OTHER TYPES OF DF TO DIC LED N2 YL CBS BEFORE SERVICING. CONDUCTORS. OR M.C. COK FAILURE TO DISCONNECT POSER FAILURE TO DO SO MAT CAUSE KI BEFORE SERVICING CAN CAUSE DAMAGE TO THE EOU IPMENT! IBK SEVERE PERSONAL INJURY OR DEATH! COLOR OF MIRE TI r TO T t K YO BADDS•8 B /F BL BLACK MIRE NI TH BLUE WARNER n '�" � � L COLOR OF OF WARNER ON BLACK OR ORANGE YL YELLOW BL BLUE RD RED OR GREEN OL . $ -O�O--•. ON' r , T.I; TYPICAL ---II BR BROWN WH WHITE PR PURPLE L PCO I I— AIR MANGLER F THERMOSTAT I HPCO -___----_� E NO X�I � YELLOW IT -I - -I -I-v ES I I., IF pp-B T IS NOT USED, ADD JUMPER BETWEEN 52!N3 Maq T AT AIR HANDLER. WXIRD •NEATER IF USED ODT-B MUST BE MOUNTED REMOTE OF CONTROL - COIIIROIf I I I I B01 IN AN APPROVED WEATHER PROOF ENCLOSURE. N rT IeR B 1 2, AT OD xANDLHOT USED.ADD JUMPER BE iSEEN NI 1 N2 ' I 1--- Y- -® E. YL�O S, LON VOLTAGE 12K V T FIELD SIRING MUST BE IB AWG MIN et R�lll 44-o IZES ODT-B E�F�,1, y 1 -. J FOR CANADIAN INSTALLATIONS o—x-111 12 J I ©— r r-0 I POUR INSTALLATIONS CANADIENNES L et _x 1 T : NOT SUITA6lE FOR USE ON ST M EXCEEDING 150V-TO-GROUND. 001-A TOPTIONALI T NE CONVIENT PAS AUX Q—x—BK x I I I I ILASTIONS DE PLUS DE 150 V A x eK x _I _-- x .�TN� 24V -�-o 10 PONEA SUPPLY J E � : PEA LOCAL CODES 1.--C� � ..J L_ .. J Printed from D156994PO2 12-1256-16 11 i xu n w�Sitw6rd M14TING a Aix CONDITIONING Electrical Data Schematic Diagrams (SEE LEGEND) 4A6H5042 TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES CA COOL IYG ANTICIPATION n CIS "O R DOIIOM 5[YSOA Cr FAY(APAFi(OR 1 Co 9191 CONNECTOR r L CPR COMPRESSOR ' SUMP HTA CR RUY CA06"AFR 1 S TOR I TDL C5 III% 4A tAPACIiGq BR/RD�-{ -a OL AR WMI�BLACK�—PUAPL EYWR�PORPLE/WM CSC (APAOS ST'O UY6 Y((Ar r DFC C{"I0 (0Y1ROL IT INWO4 FAY AFIAt �. �$-—- —•-�StE StRTICt FACTS rot OPtIOMAL°�° HA e, T,RG 'MS'I =' CSR-t CSR _srur NIT ACC[SSOW+ MS-2 MICO NJ PRESSOR[ culGul v BRnO-•lF�^rots�8OJ81� IOC iOqINT AYel OVERLOAD COD PROTECTOR I ^yi )i LPCO IOW PRESSLLAE CUIOUt SV RD S MS COMPRESSOR IM)70A COr IA(tOR 7 CAPACITOR •' - ODA GU TOOOR ANI Ic IPAt OR C Or i OU(DOOR It.THERMOSut D�l BROWII�Q-� W OM/DL ODS OU IDOOA 1(M/(RA7UA[ 5(001 FAN1 �1 OD OU 1000A IN(R1g51A1 IATR C H W CPR IOC : Ax5 r(Sl SierCt x[A1 Sn 7[A • PNNPI[ RO 6G to IC40rta retrl SOFTwo J $N SPS7(Y'Or 01f• SR I1C4 TDL DISOIAAL( 1101 lu(RMOSIAT T. iRAY i(OIY(R BLACK /II/Bl T$ P(AIIYG COOFIYO NIRMOSIAT ISM PF AIIYG tHE AMO51 A7 -— NI TDR % 01LA1 A(LAT DFC LED +t— M� tCBS GR KI N.C. CON TL_"J AI Q WARNING Q CAU710N 8M HAZARDOUS VOLTAGE! USE COPPER CONDUCTORS ONLY! DISCONNECT ALL ELECTRIC POWER UNIT TERMINALS ARE NOT DESIGNED ons-A INCLUDING REMOTE DISCONNECTS TO ACCEPT OTHER TYPES Or it I '--�--+ OCFOAC SERVICING CON Due TOR '•0~••� FAILURE 70 DISCONNECT POWER FAILURE TO DO 50 MAY CAUSE B[FORE SERVICING CAN CAUSE DAMAGE TO THE EQUIPMENT! u SEVERE PERSONAL INJURE OA DEATIII SC 0 i 81 0---M M-0—Ir ', TT►ICAI —1 FT, ZI.1AT COLOR OF WIRE I T I AIR MANOL EC LPCO 000 I _ 0 ——-_ _ 0 B /[E BL BLACK HIRE PITH BLUE HARMER HPCO I 8—COLOR OF MIN R BK BLACK OR ORANGE YL YELLOW -- —,---Q BL BLUE RD RED GR GREEN •W�AT[M OR BROWN WH WHITE PR PURPLE -- -- -CONTACT SI—I— I— M 7L-�—CA Q R—L J[ I I}— I ——�, — NOTES: I 1' )�— rTES DDT- IOP110MAt1 1 1, IT ODT-B IS N01 USED,ADD JUMPER BETWEEN 12 A W3 er �162o-REWia[IA A� I= J I n — Al AIR HANDLER. ll IF USED,007.8 MUST BE MOUNTED REM07E OF CONTROL 2 BOE. CODI-AMISPN07VUSED.WEATHER JUM PROOF BETWEENR11 C 92 AT L"" "" BM I • 3 HANDER LOW WAVOL 7AGEL 12R V 1 FIELD WIRING MUST BE 18 AVG MIN. ODY-AI IOPT IOMALI RLo---I--- B I I I POUACIINSTALLATNADIAN IIONSLCANADIIENNES YSTINS EXOCEEDIING 150V-ITABLEOTO GROU D. 2,IT ' I NE CONVI ENT PAS AU TO POWER SUPPl1 �* IN AL A IONS DE PLUS DE 150 V A PER LOCAL CODES—, J J LA TERRE. Printed from D156131 PO4 12 12-1256-16 Awo ew Shwt6 d HE.1IMG A AIK CONpItIp H1H6 Electrical Data Schematic Diagrams 4TWX5049E TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES `---MM-WAM CA COOLING ANTICIPATOR LPCO LOW PRESSURE CUTOUT$W. SUMP HTR CBS COIL SOFT PACOM SENSOR MS COMPRESSOR MOTOR CRNIACIOR R 3 TDR 1 TOl CC CAN CAPACITOR ODA OUTDOOR AMT IC IPAT011 BR/WED CW WIRE CONNECTOR OF7 OUTDOOR FAN I EANOSTAI c MO;O�BL ACN INy.M/VHM�eIKNM��NPUA/IUWM PUAPL(/WM CPC ITR COMPRESSON ODS OUTDOOR TEMPERATURE SENSOR Mri rt$ —�f([S(0.v C(FACTS FOR OPf IOWAL 4 CS SIAITI UN �NG CAPAICITOR WENS DDT RES1IST�AANCEEHEATTAT SWITCH i M$-I 'j .S1AAi All ACCESSORY M$-2 a CSR CAPACITOR SNITCHING RELAY SC SWITCHOVER VALVE SOLENOID . 11 C$R-I C$R Dr[ DCFROSr CONTROL SM SYSTEM'ON-OFF'SWITCH RD�t eA I 1 f—eNPeL—t L-•a1 T INDOOAR RELAY FOIL DISCHARGE LIME THERMOSTAT u NA NCATINR FG ANTICIPATO11 TNS TRANSFORMER ''., APCO NIGH PRESSURE CUTOUT SW 15 HEATING-COOLIAG THERMOSTAT IOL INTERNAL OVERLOAD PROTECTOR ISH HEATING THERMOSTAT /IcD�BADAM�Q �00 r C eA/el TDR TIME DELAY RELAY I�/�� FAN CF CR R CPR 10L T �M!T R,iPUR►L(LR NDM�RD J ilk THERMALLY PROTECTED ©WARN LNG 0 CAUTION I NTCRNALLY BLACR Mill HAZARDOUS VOL El USE COPPER CONDUCTORS ONLY! I DISCONNECT ALL ELECTRIC POWER UN17 TERMINALS ARE NOT DESIGNED DFC "R INCLUDING REMOTE G DISCONNECTS TO ACCEPT OTHER TYPES OF LED Tl CBS BEFORE SERVICING. CONDUCTORS. GR K3 N C. CON > YL FAILURE TO DISCONNECT POWER FAILURE TO DO SO NAY CAUSE RI BEFORE SERYIC ING CAN CAUSE DAMAGE TO THE COOIPNENI! eR SEVERE PERSONAL INJURY OR DEATH! • R 71 T I II TO r --}eR 00$-B 8 SC 0 COLOR OF NI RE Ol-..-.zo OR 0"-0-r-�-'-1 ATT IA NAL TYPICAL BIKKV BLACK Atx WIRE WITH BLUE MARKER 6I 1 I I— Alt YAWOL[A� I—TN(NMOSIAi `COLOR OF HARMER HPCO LPCO I L-- __ -•-__QD BK BLACK OR ORANGE YL YELLOM BL BLUE RD RED GR GRC EN BR BROWN WN WHITE PR PURPLE --�-TNEWT! M nipF I I I NOTES:A 1-7-[WNIRaf----4) }II s 1 1F ODT MAN NOT USED.ADD JUMPER BETWEEN R 1 W3 -�I -�-@ I Al AIR MANDLER. Rp I 1 I IF USED,O)T•B MUST BE MOOTED REMOTE OF CONTROL NpT[S OD1•B LO►f IONALF, ( —" 001 IN AM APPROVED RATHER PROOF EMCLOSUR[. 1A2 IN(ADI[1 - /1 _ 2. IF ODT•A IS NOT USED.ADD JUMPER BETWEEN WI 1 Wt AT All j o—x_u 3. LOU VOL TAG Zi v..FIELD WIRING MUST BE 18 AVG N1M. OUL IOPT IONALI o—x—u x x u x TDR relay cycles sump heat off dur- .vacf IL(` �i P`IAg9f��9LR delays 00091RN39A @A9UR @i1N I NT91S C801savIrmseed.1FOR USE ON IOUs rPYI I SYSTEMS EXCEEDING 15OV-TO-GROUND. ND --1---- R -i-i-O Air r. TO POWER SUPPNJ - IN ALLA IONS DE PLUS DE ISO V A PEA LOCAL COD[5 T _j LA TE WERE. PRINTED FROM D157471 P03 12-1256-16 13 Awo eav Shwdard HEATING A AIR CONDITIONING Electrical Data Schematic Diagrams (SEE LEGEND) 4TWR5061 E TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES ---r RR CA COOLING ANTICIPATOR LPCO LON PRESSURE CUTOUT SW, W SUMP NTR CBS COIL BOTTgI SENSOR HIS COMPRESSOR MOTOR CONTACTOR Cf FAR EAPA[ITON ODA OIIIDOON AMIICIPATON ED` CN MIN[CONNECTOR Or, OUTDOOR FAN THERMOSTAT tlNINUHiT tlLACW�•!�/�/�/`��nl AtA�t�rUNrlVNrl•••�—T—>�rl'Vll lYtl CPN COMPRESSOR OOS OUTDOOR 1ENP[RAIUR[SENSOR CA RUR CAPACITOR DDT OU1000R IHERN05TA1 I r'(S `;' CS 51AR11M0 CAPACITOR INS RESISTANCE HEAT SWITCH M$ I T I SIANI Lit MS-2 o CSR CAPACITOR SNITCHING RELAY SC SIII TCHOYER VALVE SOLENOID C SR I ($A IBArxi ttSJ DFC BEFRO51 CONTROL SN SYSTEM ON-Orr•SNITCH �RD� IN r� -BHIIt- — f� F II DOOR FAM RELAY TDL DISCHARGE LINE THERMOSTAT NO IORi t HA HEATING AY7IC IPATOR TIS IRANSFOIIMER xPCO NIGH PRESSURE CUTOUT SN. T$ xFATI"GIGGLING THERMOSTAT • N IOL INTERNAL OYCNLOAD PROTEC70R TEN HEATING INCRMDf1A1 D`T BROWN ON BNIe! ION LIME DELAY RELAY S��MTR 1FAN1 C NI'DC� R CPR mVARNING l m c5u110x PUIOI[ NO HAZARDOUS VOLTAGE! USE COPPER CONDUCTORS ONLY! *IH[RNAL I PROT[CTED DI SCONM[CT All[L[C1R IC POWER UNIT TERMINALS ARE NOT DESIGNED INIERNALN St ACN BN/Bl IMCLUD ING REMOTE DISCONNECTS TO ACCEPT OTHER TYPES OF FOR[�FC � FAILURE STO DISCO. CONDFAILURE LED OO��(( tt��))----{}�-- FAILURE TO DISCONNECT PoNER FAILURE TO DO°D MAT CAUSE CBS BEFORE SERVICING CAN CAUSE DAMAGE 10 THE EOUI PM[N11 GR N7 N-C. CON �)T Ytt I SEVERE PERSONAL INJURY OR DEATH! I eR L t COLOR OT MIRE OL BL ACR NI RE MI TN BLUE MARNCR (( j 11ei UUJ'B L COLOR OF MARM[R n ^� ?� 1 �n{--. n�n.`�� .. BN BLACK OR ORANGE YL YELLOW +17 L J BL BLUE RO RED GR GREEN d BR BROWN NH WHITE PR PURPLE Sc o - It ON OR-0 TTPICAt TYP.CA. NOTES: �i I F AIR NANOLEI-I I—THIIMOSIAT -1 1, IF ODT-B IS NOT USED,ADD JUMPER BETWEEN 112 A NJ HPCO SPED 0000 E`— -- AT AIR HANDLER. I — —Q IT USED,ODT-B MUST BE NOUNIED REMOTE OF CONTROL e01 IN AN APPROVED WEATHER PROOF ENCLOSURE t IF ODT.A IS NOT USED.ADD JUMPER BETWEEN NI I 12 I AT AIR HANDLER LOW VOL TAO[ TEA Y.1 YIELD■IRINO MOST e[ 18 AN NIN. � HUIEW . M �I._AR e .. ^ - --�- coxnoul I I I FOR CANADIAN INSTALLATIONS a I POUR INJIALLAI IUNJ (,ANAUILNNLJ TI NOT SUITABLE FOR USE ON ISTEM EXCEEDING 150V•70 GROUND. INCT[S ODl-B (OPTIONAL$, ! I — ' ATTENTION: NE CONVIENT PAS AUX .IBi , —o-x-8A--R F2 III a f r-0 I LASTERRE INSTALLATIONS OE PLUS OE 150 V A C I I ..—..eN.�::j—S OD1-A .IQPT IQNALI TDR relay cycles sump heat off dur- ing compressor operation and delays BLS------S energizing the sump heat for 30 mins Nafter"Y"call is removed. -�-a-o TO POWER SUPPLY PER LOCAL CODES _ •J L— — J Printed From D157472PO2 14 12-1256-16 AficwN w SAw6fd of Ai1HG . n10. CO,10liIOMI,.G Dimensions 4A61-15 Outline Drawing Note:All dimensions are in MM(Inches). B C ELECTRICAL AND RIFR IGFRA■i S[A"C1 COHPONENI PANEL — CLEARANCES PER PRCYAILIRG CDOCS ILE TOP DISCHARGE AREA SHOULD BE UNAf STRICTED FOR AT LEAST 1524 IS FEET) ASDYC UNIT UNIT SNOULD BE PLACED SO ROOF lip RUNOFF TA 1 ER DNS NOT POUR DIRECTLT ON UNIT, K AND SHOULD BE AT LEAST 305 112'1 FROM WALL AN ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER IWO SIDES UNRESTRICTED ft((I■iClt SIAYi([IMCL 151i1 FIM 2 *F.1E1'1U1 ll■1 SERWICI 22 2(I'll Loo x0.t •E•1 D FEMALE to.VOL rrl:t co.■tcnOR IA'SAE FLARE 1W.N" "N1 Do' N0. E rV FIRING AI rN r2 7 11/U 0IA xotl IN L0■ua DON 0o110N FOR Itlt F■IC.I COCA u It I10U10 LINE STRIKE vuvl,•E•I 0 IE■u[ Durt cONNt[na an vA•[AE CLANt H nunGs. FLi F'1 N 0 FOR ALTERNATE ELECTRICAL ROUTING D' I D FIHAI[ A10HAI lA1 11 LI1 NG I 0 IIHARI Wu2f0 CpN[CIION.110 1/1 SA[ FlM[Iq[S[C■()AI FIi IINL MODELS BASE A B c D E F G H J K 4A6H5018G 4 730(28-3/4) 829(32-5/8) 756(29.3/4) 5/8 3/6 143(5-5/8) 92(3-5/8) 210(8-1/4) 79(3.1/8) 508(20) 4A6H5024G 3 832(32-3/4) 829(32-5/8) 756(29-3/4) 5/8 3/8 143(5-5/8) 92(3-5/8) 210(8-1/4) 79(3-1/8) 508(20) 4A6H5030G 4 841(33-1/8) 946(37-1/4) 870(34-1/4) 3/4 3/B 152(6) 98(3-7/8) 219(8-5/8) 86(3-3/8) 506(20) 4A6H5036G 4 841(33-1/8) 946(37-1/4) 870(34-1/4) 3/4 3/8 152(6) 98(3-7/8) 219(8-5/8) 86(3-3/8) 508(20) 4A6H5042G 4 943(37 1/8) 946(37-1/4) 870(34-1/4) 3/4 3/8 143(5-5/8) 98(3-7/8) 219(8-5/8) 86(3-3/8) 508(20) 4A6H5049E 4 1147(45 1/8) 946(37-1/4) 870(34-1/4) 7/8 3/8 152(6) 98(3-7/8) 219(8.5/8) 86(3-3/8) 508(20) 4A6H5061E 4 1147(451/8) 946(37-1/4) 870(34-1/4) 1-1/8 3/8 152(6) 98(3-7/8) 219(8-5/8) 86(3-3/8) 508(20) From Dwg.DI52862 12-1256-16 15 Mechanical Specification Options General Condenser Coil The 4A6H5 is fully charged from the The outdoor coil provides low airflow factory for up to 15 feet of piping.This resistance and efficient heat transfer. unit is designed to operate at outdoor The coil is protected on all four sides by ambient temperatures as high as 115°F. louvered panels. Cooling capacities are matched with Low Ambient Cooling a wide selertion of air handlers and As nidnuraclured, this unit has a cooling furnace coils that are AHRI certified.The capability to 55°F.The addition of an unit is certified to UL 1995.Exterior is evaporator defrost control with TXV designed for outdoor application. permits low ambient cooling to 20'F. Casing Accessories Unit casing is constructed of heavy I hermostats—Cooling only and gauge,G90 galvanized steel and heat/cooling(manual and automatic painted with a weather-resistant powder changeover).Sub-base to match paint on all louvers,panels,prepaint thermostat and locking thermostat cover. on all other panels.Corrosion and weatherproof CMBP-G30 DuraTuffT"^ base. Refrigerant Controls Refrigeration system controls include condenser fan and compressor contactor. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Compressor The DURATIONT"'compressor features internal over temperature and pressure protection and total dipped hermetic motor.Other features include:centrifugal ail pump and low vihration and noise COTED us Z Intertek A*a ear S*4fdwd HEATING & AIR CONDITIONING 08/14 American Standard Heating&Air Conditioning www.americanstandardaircom American Standard Heating&Air Conditioning has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. Search L&I - Safety&Health 6 Claims&Insurance Workplace Rights Trades Washington State Department of " Labor & Industries C M HEATING INC Owner or tradesperson 1415 BROADWAY Principals EVERETT,WA 98201 Garner,James N,PRESIDENT 425-259-6666 SNOHOMISH County Umayam,John A,VICE PRESIDENT ■ Umayam,Antonio(Tony)G,SECRETARY Umayam,Antonio(Tony)G,TREASURER Garner,James N,AGENT Garner,Paul,PRESIDENT (End:06/29/2016) Garner,Kathleen D,SECRETARY (End:06/29/2016) Garner,Kathleen D,TREASURER (End:06/2912016) Doing business as C M HEATING INC WA UBI No. Business type 601 114 652 Corporation Governing persons JAMES GARNER PAUL M GARNER; KATHLEEN GARNER; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Electrical Contractor Active Meets current requirements. License specialties GENERAL License no. CMHEAMH877DN Effective—expiration 03115/2013—03/15/2021 Designated administrator Active Glacomi,John Meets current requirements. License type License no. Electrical Administrator GIACOJ"840MG Bond Contractors Bonding&Insurance Co $4,000.00 Bond account no. SC6810 Help us improve Received by L&I Effective date 03115/2013 02/28/2000 Expiration date Until Canceled Savings ... ................. No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Certifications&;Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent ................... Not allowed to have apprentices. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 490,794-01 Doing business as CHIMNEY MASTERS Estimated workers reported Quarter 2 of Year 2019"31 to 50 Workers" L&I account contact T3/NICHOLE CAROW(360)902-5634-Email:CAN1235@lni.wa.gov Public Works Requirements Verify the contractor is eligible to perform work on public works projects. Required Training—Effective July 1,2019 Needs to complete training. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 03/16/2015 No violations Inspection no. 317935327 Location 1415 Broadway Everett,WA 98201 ilV IA ,, In :•i,,. Help us improve