Loading...
HomeMy WebLinkAbout7722 E Country Club Dr_BLD2349_2025 NOTICE TO PERMITEE AND/OR OWNER {{{ ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY /APPROVED PERMIT#: r LOT#: DATE: JOBADDRESS: TYPE OF INSPECTION: '. � �4 r ". _l j( E.�}t ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK:MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 Cl CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY, FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE: BUILDING DEPT. o PLANNING DEPT. CITY OF ARLINGTON I CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:7722 E Country Club Dr Permit N-2349 Parcel p:00809200004100 Valuation:0,00 OWNER APPLICANT CONTRACTOR Name;POLLARD LLOYD W&DOROTHY C Name:CM Ileating Name;CM Heating Inc Address:7722 E COUNTRY CLUB DR Address:1415 Broadway Address: I415 Broadway City,State Zip:ARLINGTON,WA 98223 City,State Zip:Everett,WA 98204 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address: 1415 Broadway Address: City,Stale,Zip:Everett,WA 98201 City,Slate,Zip: Phone:425-259-0550 Phone: LIC M CMHEAMH877DN EXP: 03/15/2019 LIC k: EXP.- JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES; CONST.TYPE; DWELLING UNITS; OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OFTHE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED, IBCI 101IRCI 10. -SALFS TAX NOTICE:Sales tax relating to construction and construction materials in the City of Artington must be reported on your sales tax return form and coded City o riington U3101, D--We—RQA.L,--rr— I Cl lexm —�L(o m Si urc. Print Name Date eleas , By U Date CONDITIONS Adhere to approved appliance, Please call for final inspection. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED,THIS PERMIT COVERS WORK TO HE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 1/1W2019 Mechanical Fee(Enter Fixture Fee) $25.00 1/10/2019 Mechanical Permit Base Fee $25.00 1/10/2019 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit Information Date 1/10/2019 Permit Number 2349 Project Name CM Heating-7722 E Country Club Applicant Name CM Heating Applicant Address 1415 Broadway City,State,Zip Everett,WA 98204 Contact Phone 425-259-0550 Email debbie@cmheating.com Permit Type Residential Mechanical Site Address 7722 E Country Club Dr Valuation 0.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Residential Mechanical Number of Stories 0 Proposed Use SFR Gas Furnace replacement Assigned To Raelynn Jones Property Owner Parcel Address Legal Owner Phone Zoning 00809200004100 7722 COUNTRY CLUB POLLARD LLOYD W&DOROTHY 111 Single Family Residence- DR C Detached Contractors Contractor Name Primary Contact Phone Email =ontractor Type License License# CM Heating Inc jDebbie Bauers 25-259-0550 iebbie cmheatin .com IMECHANICAL CONTRACTOR Labor&Industries :;MHEAMH877DN Fees Fee Description Notes Amount Mechanical Fee Enter Fixture Fee 322.10.00.00 $25.00 Mechanical Permit Base Fee 322.10.00.00 $25.00 Processing/Technology Fee 341.43.00.02 $25.00 Total $7L Uploaded Files Upload File Date File Uploaded B 1/10/2019 9:54:01 AM IL349 Application.pdf I Jones, RaelynnC CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:7722 E Country Club Dr Permit#:2349 Parcel#:00809200004100 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:POLLARD LLOYD W&DOROTHY C Name:CM Heating Name:CM Heating Inc Address:7722 E COUNTRY CLUB DR Address:1415 Broadway Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223 City,State Zip:Everett,WA 98204 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address: 1415 Broadway Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone: LIC#:CMHEAMH877DN EXP: 03/15/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1 l0/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. q Signature Print Name Date eleas By Date CONDITIONS Adhere to approved appliance. Please call for final inspection. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 1/10/2019 Mechanical Fee(Enter Fixture Fee) $25.00 1/10/2019 Mechanical Permit Base Fee $25.00 1/10/2019 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:7722 EAST COUNTRY CLUB DR, ARLINGTON, WA 98223 Project Description:REPLACE GAS FURNACE-LIKE FOR LIKE Owner: WAYNE POLLARD Address: 7722 EAST COUNTRY CLUB R City:ARLINGTON StateYVA Zip Code: 98223 Phone: 425-760-8971 Email:waynecom@comcast.net Applicant: C.M. HEATING INC Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98204 Phone: 425-259-0550 Email: DEBBIE@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:C.M. HEATING INC Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration: 05/19 Phone:425-259-0550 Email:DEBBIE@CMHEATING.COM STAFF USE ONLY Received Permit#: 2' 49 Accepted by Date: JAN 0 9 2019 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION — Department of Community& Economic Development City of Arlington • 18204 59th Ave NE • Arlington,WA 98223 • Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #ADE1A060A9361A AFUE80% ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER IJ Freestanding Stove IJ Fire Place insert Lj Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: 16 Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Tr-)t�l RTI I'c of III Orrrliarr roc • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gds lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances aZ)� liY�s Applicant Signature: Date: 01/09/2019 Applicant Printed Name: Debbie Bauers I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 TDE1 A060A-SUB-1 B TAG: Downf low/Horizontal Induced Draft 5/8" Single Stage Gas Furnace 14-1/2' 28' TDE1 A060A9361 A ADE1 A060A9361 A 5/" SIDE PANEL 1/2' CUTOUT FOR 5"0 SIDE PANEL CUTOUT y HORIZONTAL FOR HORIZONTAL VENTING ' VENTING THROUGH THE CABINET 9.5/8' THROUGH ,- ` 7/8"DIA.HOLES THE CABINET� � ELECTRICAL 3-112 5" CONNECTION i ,I 3-3/8 i 40 7/8"HOLE 7" WITH PLUG FLU` _ 3/4` 31 2-1/8' OPENING4-0 ` j 29-1 ' 1-5/8"HOLE WITH PLUG -112"DIA.GAS ®� 20-1/4' CONNECTION (ALTERNATE) �'�' • ���� I 1-5/8"HOLE 3/4` 12 3/8" 3-15/16 I WITH PLUG 10^ 10.. 0 19" 8-1/4' 5-5/16" 1-5/8"HOLE WITH PLUG 3-3/4" 1-5/8"DIA.HOLE WITH PLUG GAS CONNECTION(ALT) 1-5/8"HOLE WITH PLUG FURNACE AIRFLOW(CFM)VS.STATIC PRESSURE(ins.w.g.) MODEL SPEEDTAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 4- HIGH-Black 1480 1429 1375 1318 1282 1100 1112 1029 959 TDE1A060A9361A 3- MED.-HIGH-Blue 1302 1276 1229 1188 1141 1088 1024 953 882 ADE1 A060A9361 A 2- MED.-LOW-Yellow 1115 1100 1070 1035 1000 965 918 859 790 1 - LOW- Red 956 947 918 888 859 824 788 741 682 CFM VS.TEMPERATURE RISE CFM (CUBIC FEET PER MINUTE) MODEL 800 900 1000 1 1100 1 1200 1 1300 1 1400 TDE1 A060A9361 A 56 49 44 40 37 34 32 ADE1 A060A9361 A ©2015 Ingersoll Rand $�A 1 Jl1 General Data o TYPE Downf low/Horizontal VENT COLLAR—Size(in.) 4 Round HEAT EXCHANGER Input BTUH 60,000 Type-Fired Alum.Steel Capacity BTUH(ICS) 0 48,000 -Unfired AFUE 80.0 Gauge(Fired) 20 Temp.rise(Min.-Max.)°F 30-fin ORIFICES—Main BLOWER DRIVE DIRECT Nat.Gas.Qty.—Drill Size 3—45 Diameter-Width(In.) 11 x 7 L.P.Gas Qty.—Drill Size 3—56 No.Used 1 G S E Redundant-Sin le Stage Speeds(No.) 4 PILOT SAFETY DEVICE CFM vs.in.w.g. See Fan Performance Type Hot Surface Ignition Motor HP 1/2 BURNERS—Type Multiport Inshot R.P.M. 1075 Number 3 Volts/Ph/Hz 115/1/60 POWER CONN.—V/Ph/Hz U 115/1/60 COMBUSTION FAN-Type Centrifugal Ampacity(In Amps) 11.2 Drive-No.Speeds Direct-1 Max.Overcurrent Protection(amps) 15 Motor HP-RPM 1/50-3180 PIPE CONN.SIZE(IN.) 1/2 Volts/Ph/Hz 115/l/60 DIMENSIONS H x W x D F.L.Amps 1.09 Crated(In.) 41-3/4 x 16-1/2 x 30-1/2 FILTER—Furnished? No Uncrated(In.) 40 x 14-1/2 x 28-1/2 Type Recommended High Velocity WEIGHT Hi Vel.(No.-Size-Thk.)Shipped 2-14 x 20-iin. Shipping(Lbs.)/Net(Lbs) 129/119 O Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3. O Ratings shown are ror elevations up to zuuu reel.For elevations above zuuu reet',Hatings should be reduced at the rate of 4%for each 1000 reel above sea level. O Based on U.S.Government Standard Tests. O The above wiring specifications are in accordance with National Electrical Code;however,installatiuns must uumply will luual uudus. Mechanical Specifications NATURAL GAS MODELS — Central BURNERS — Multi-port, in-shot burners STYLING — Heavy gauge steel and heating furnace designs arc certified by will give years of quiet and off iciont service. "wraparound" cabinet construction is the American Gas Association for both All models can be converted lu L.P. gas used in the cabinet with baked-on enamel natural and L.P.gas.Limit setting and rating without changing burners. finish for strength and beauty.The heat ex- data were established and approved under INTEGRATED SYSTEM CONTROL— changer section of the cabinet is completely standard rating conditions using American Exclusively designed operational program lined with foil-faced fiberglass insulation. National Standards Institute standards. This results in quiet and efficient operation provides total control of furnace limit sen- due lu ills excellettl dc;uuslical altll iltsuldl- SAFE OPERATION—The Integrated Sys- sors,blowers,gas valve,flame control and ing qualities of fiberglass. tem Control has solid state devices,which includes self diagnostics for ease of service. continuously monitorforpresence of flame, FEATURES AND GENERAL OPERATION when the system is in the heating mode of AIR DELIVERY—The h suffmulticient dent direct — These High Efficiency Gas Furnaces operation. Dual solenoid combination gas range drive blower motor, with sufficient airflow employ a Hot Surface Ignition system,which valve and regulator provide extra safety. meets, will switcr most h from heating nd tocooierequire- eliminates the waste of a constantly burning meets, will switch from heating to cooling pilot. The integrated system control lights QUICK HEATING—Durable,cycle tested, speeds on demand from room thermostat. the main burners upon a demand for heat heavy gauge aluminized steel heat ex- The blower door safety switch will prevent from the room'thermostat. Complete front changer quickly transfers heat to provide or terminate furnace operation when the warm conditioned air to the structure. Low blower door is removed. (Fan relay and service access. energy power vent blower,toincreaseef- 35VA control transformer is standard). a. Low energy power venter. f iciency and provide discharge of gas fumes b. Vent proving differential switch. to the outside,allows rommen venting with hot water heater. Sinceingersoll Rand has a policy of continuous product and Library Unitary product data improvement,it reserves the right to change Product Section Furnaces specifications and design without notice. Product Furnace Technical Literature-Printed in U.S.A. Model TDE1 Literature Type Submittal Sequence Ingersoll Rand Date 05/15 Tylerr,,TX 620 Highway c US File No. TDE1 A060-SUB-1 B TX 75707 www.trane.com Intertek Supersedes TDE1A060-SUB-1A i N-Zhidex Help My L&I kAL' a' bor & Industries Safety&Health 0 Claims&Insurance 0 Workplace Rights 0 Trades&Licensing a Washington State Department of " Labor & Industries C M HEATING INC Owner or tradesperson 1415 BROADWAY EVERETT,WA 98201 Principals 425-259-6666 Garner,James N,PRESIDENT SNOHOMISH County ■ Umayam,John A,VICE PRESIDENT Umayam,Antonio(Tony)G,SECRETARY Umayam,Antonio(Tony)G,TREASURER ■ Garner,James N,AGENT Garner,Paul,PRESIDENT (End:06/29/2016) • Garner,Kathleen D,SECRETARY (End:06/29/2016) ■ Garner,Kathleen D,TREASURER (End:06/29/2016) Doing business as C M HEATING INC WA UBI No. Business type 601 114 652 Corporation Governing persons JAMES GARNER PAUL M GARNER; KATHLEEN GARNER; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. CMHEAMH877DN Effective—expiration 03/15/2013—03/15/2019 Designated administrator Active. Giacomi,John Meets current requirements. License type License no. Electrical Administrator GIACOJ"840MG Bond Contractors Bonding&Insurance Co $4,000.00 Bond account no. SC6810 Received by L&I Effective date 03/15/2013 02/28/2000 Expiration date Until Canceled ,Savings. No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 490,794-01 Doing business as CHIMNEY MASTERS Estimated workers reported Quarter 3 of Year 2018"51 to 75 Workers" L&I account contact T1/NICHOLE CAROW(360)902-5634-Email:CANI235@Inl.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was iespunsible fui. Inspection results date 03/16/2015 No violations Inspection no. 317935327 Location 1415 Broadway Everett,WA 98201 --- - Help us 1ca�s _ �\I`aahington�° improve