Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18333 Cedarbough Loop_BLD2333_2025 (3)
NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ _DO NOT OCCUPY gAPPROVED PERMIT#: '�_f s1 lj LOT#: DATE: ,._ JOB ADDRESS: TYPE OF INSPECTION: .,, �a ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK:MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. Cl CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE BUILDING'bEPT. Cl PLANNING DEPT CITY OF ARLINGTON �� CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 RUING PERMIT Address:18333 Cedarbough Loop Permit M:2333 Parcel th(X)738500405500 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:KUHL DAVID&LAURA Name:Cozy Heating,Inc. Name:COZY IIFATING Address: 18333 NORTH CEDARBOUGH LOOP Address:20221 67111 Avenue NE Address:20221 67th Avenue NE City,State"Zip:ARLINGTON,WA 98223 City,State Zip:Arlington,WA 98223 City,State Zip:ARLINGTON,WA 98223 Phone: Phone:3M)435J4%9 Phone:360.435-W04 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name,COZY HEATING Name: Address:20221 67th AvenueNF Address: City,State,Zip:ARLINGTON,WA 98223 City,State,Zip: Phone:360-435-4904 Phone: LIC d:COZYHl"122MM EXP: 12/22/2019 L1C/f: EXP: JOB DESCRIPTION II PERMIT TYPE: Residential Mechanical CODE YE-AR: 2015 ST0RIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WrrH CITY AND STATE LAWS REGULATING CONSTRUI.'TION AND IN DOING 71IE WORK AUTIIORIZFD'TI1ERERY; NO PERSON WILI.BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RFLATING'r0 WORKMI N'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT L'NTIL SIGNED BY THE BUILDING OFFICIAL OR HfS/IIER DEPUTY AND ALL FEES.ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCI'URF.UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI I0/IRC110. SALES TAX NOTICE:Sales tax relating to construction and corutruction materials in the City of A st r rted on your sales tax relum form and coded :it)-ufArlington I#3101. Signature Print Name /Date Released By Date CONDITIONS Approved as submitted. Inspection required. r11IS PERMIT AIM[ORIZS ONLY TIIE WORK NOTED.11[IS PERMIT COVERS WORK TO BF DONE ON PRIVATE PROPERTY ONLY ANY CONSTRUCTION ON TIIF PUBLIC DOMAIN(CURBS,SIDEWALKS,ORIVPWAYS,MARQUEES.ETC.)WILL REQUIRF SFPAKATE PERMISSION PERMIT FEES Date Description Fee Amount 1/212019 Furnace $25.00 1/2/2019 Mechanical Permit Base Fee $25.00 1/2/2019 Processing/Technology Fee $25.00 Total Due; $75.00 Total Payment: %00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)40-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning nr afternoon GITY OF ARLINGTON `\ 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 _ PHONE; (360) 403-3551 BUILDING PERMIT Address:18333 Cedarbough Loop Permit#:2333 Parcel#:00738500405500 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:KUHL DAVID&LAURA Name:Cozy Heating,Inc. Name:COZY HEATING Address: 18333 NORTH CEDARBOUGH LOOP Address:20221 67th Avenue NE Address:20221 67th Avenue NE City,State Zip:ARLINGTON,WA 98223 City,State Zip:Arlington,WA 98223 City,State Zip:ARLINGTON,WA 98223 Phone: Phone:360-435-4904 Phone:360-435-4904 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:COZY HEATING Name: Address:20221 67th Avenue NE Address: City,State,Zip:ARLINGTON,WA 98223 City,State,Zip: Phone:360-435-4904 Phone: LIC#:COZYHI*122MM EXP: 12/22/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of A n1strorted on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By Date CONDITIONS Approved as submitted. Inspection required. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 1/2/2019 Furnace $25.00 1/2/2019 Mechanical Permit Base Fee $25.00 1/2/2019 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit Information Date 1/2/2019 Permit Number 2333 Project Name Kuhl Applicant Name Cozy Heating,Inc. Applicant Address 20221 67th Avenue NE City,State,Zip Arlington,WA 98223 Contact Steven Maisch Phone 360-435-4904 Email info@cozyheatinginc.com Permit Type Residential Mechanical Site Address 18333 Cedarbough Loop Valuation 0.00 Status Ready to Issue Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use Replace Gas Furnace Assigned To Kristin Foster Property Parcel Address Le al Owner Owner Phone Zoning 00738500405500 118333 CEDARBOUGH LOOP IKUHL DAVID&LAURA 111 Single Family Residence-Detached Contractors Contractor Name Primary Contact �Pho:n:e:::E Email Contractor Type License License# COZY HEATING ✓ince Willett 060-435-4904 nfo coz heatin inc.com MECHANICAL CONTRACTOR -abor&Industries COZYH1*122MM Fees Fee Descri tion Notes Amount Furnace 322.10.00.00 $25.00 Mechanical Permit Base Fee 322.10.00.00 $25.00 Processing/Tech olo Fee 341.43.00.02 $25.00 Total $75.00 Uploaded Files Upload File Date File Uploaded B 1/2/2019 1:14:47 PM 2333 Applicauon.pdf Foster,Kristin 1/2/2019 1:14:47 PM 2333 Spgcs.pdf Foster,Kristin x 1/2/2019 1:13:54 PM 2333 Application.pdf Foster,Kristin x �. RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:18333 Cedarbough Loop Arlington, Wa 98223 Project Description:Replace 80% Nat. Gas Furnace with 95% Nat. Gas Furnace Owner: Laura Kuhl Address: 18333 Cedarbough Loop City:Arlington StateWa Zip Code: 98223 Phone: 360-722-4593 Email:laurabkuhl@aol.com Applicant: Cozy Heating, Inc. Address:20221 67th Ave NE City: Arlington Stated Zip Code: 98223 Phone: 360-435-4904 Email: smaisch.cozy@gmail.com CONTRACTOR INFORMATION Contractor Name:Cozy Heating, Inc. Address:20221 67th Ave NE City: Arlington StateWa Zip Code: 98223 License Number:CC COZYHI*122MM Expiration: 12/22/2019 Phone:360-435-4904 Email:info@cozyheatinginc.com STAFF USE ON ReCO9v Permit #: 2Z7�;� Accepted by: Date: 6/16 LP Page 1 of 2 Gt N. RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES i Furnace (80+) Model ##S9X2B060D3PS AFUE95% ❑! Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑? Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping U Solid-Fuel Appliance L+ Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: »�......� ... ...»> -J Date: 01/02/2019 Applicant Printed Name: Steven Maisch I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 Home Espafiol Contact SfARCH Safety&Health a Claims&Insurance a Workplace Rights c Trades&Licensing c A^ Washington State Department of " Labor & Industries COZY HEATING INC Owner or tradesperson 20221 67TH AVE NE ARLINGTON,WA 98223 Principals 360-435-4904 WILLETT,VINCE LEE,PRESIDENT SNOHOMISH County • WILLETT,CARINA ANN,VICE PRESIDENT • WILLETT,CAROL A,SECRETARY (End: 12/18/2013) • DOWREY,ROBIN B,TREASURER (End: 12/18/2013) Doing business as COZY HEATING INC WA UBI No. Business type 601 088 561 Corporation Governing persons VINCENT LEE WILLETT CARINAANN WILLETT, License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. COZYHI"122MM Effective—expiration 07/14/1988-12/22/2019 Bond TRAVELERS CAS&SURETY CO $12,000.00 Bond account no. 206085693 Received by L&I Effective date 12/18/2001 12122/2001 Expiration date Until Canceled Insurance Federated Mutual Ins Co $1,000,000.00 Policy no. 9290637 Received by L&I Effective date 04/09/2018 04/15/2017 Expiration date 04/15/2019 improve Insurance history Savirlys No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. This company has multiple workers'comp accounts. Active accounts L&I Account ID Account is current. 813,971-00 Doing business as COZY HEATING INC Estimated workers reported Quarter 3 of Year 2018"31 to 50 Workers" L&I account contact T5 I MELISSA VEST(360)902-5613-Email:VESM235@lni.wa.gov Track this contractor A Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. -- - liica5 It►IYashington" a . Submittal Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTU H Downflow Only S9X2B060D3PSAB >,M5 I Pe Received Note:Graphics in this document are for representation only.Actual model may IAN 02 ?018 differ in appearance. V TAG: t Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. July2018 S9X2B060D3-SUB-1 B-EN APIngerwIl Rand. Outline Drawings p Q v v• s e� t ? a = 3- _ a• N U f0 z C s L n }J U- C o cu v 3 N o m . ®❑O Jk Z i z a z xr�4 0¢ c n e _ 3 a a:i se ®�e eWW a�: a �Y =3 a2 MA 8� Product Specifications MODEL S9X2BO6OD3PSAB(a) MODEL S9X2BO6OD3PSAB(a) TYPE Downflow —Unfired 29-4C Stainless Steel RATINGS(b) Gauge(Fired) 20 1st Stage Input BTUH(ICS) 39,000 ORIFICES—Main 1st Stage Capacity BTUH 37,830 Nat.Gas Qty.—Drill Size 3-45 2nd Stage Input BTUH 60,000 LP Gas Qty.—Drill Size 3-56 2nd Stage Capacity BTUH(ICS)(c)(d) 58,200 GAS VALVE Redundant-Two Stage 1st Stage Temp.Rise(Min.-Max.) 25-55 PILOT SAFETY DEVICE 2nd Stage Temp.Rise(Min.-Max.) 35-65 Type 120 V SiNi Igniter AFUE(%) 95.0 BURNERS—Type Multiport Inshot BLOWER DRIVE DIRECT Number 3 Diameter—Width(In.) 11 X 8 POWER CONN.—V/Ph/Hz(h) 120/1/60 No.Used 1 Ampacity(In Amps) 9.3 Speeds(No.)(e) 5 Max.Overcurrent Protection(Amps) 15 CFM vs.in.w.g. See Fan Performance PIPE CONN.SIZE(in.) 1/2 Table Motor HP 1/2 DIMENSIONS H x W x D RPM 1075 Uncrated(In.) 34 x 17-1/2 x 28-3/4 Volts/Ph/Hz 120/1/60 Crated(In.) 35-1/2 x 19-1/2 x 30-7/8 FLA 6.8 WEIGHT COMBUSTION FAN—Type Centrifugal Shipping(Lbs.)/Net(Lbs.) 127/119 Drive—No.Speeds Direct 2 (a) Meets Energy Star (b) For U.S.applications,above input ratings(BTUH)are up to 2,000 Motor HP—RPM 3300/2600 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applications,above input ratings(BTUH)are Volts/Ph/Hz 120/1/60 up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. FLA 0.66 (_) Central Furnace heating designs are certified to ANSI Z21.47/CSA FILTER—Furnished? No 2.3. (d) Based on U.S.government standard tests. Type recommended High Velocity (e) 5 Speed constant torque ECM blower motor (f) Refer to the Vent Length Table in the Installer's Guide. Hi Vel.(No.-Size-Thk.) 2—14x20—1 in. (9) All S9X2 furnace models have a vent outlet diameter that equals 2 in. VENT PIPE DIAMETER—Min(in.) (h) The above wiring specifications are in accordance with National M(g) 2 Round Electrical Code;however,installations must comply with local codes. HEAT EXCHANGER Type—Fired 409 Stainless Steel S9X2B060133-SUB-1 B-EN 3 Heating and Cooling Airflow Tables Table 1. Downflow Cooling Table FURNACE AIRFLOW(CFM)VS.STATIC PRESSURE(insm.g) MODEL SPEEDTAP 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 5-HIGH 1462 1431 1400 1369 1335 1298 1256 1210 1165 4-MED-HIGH 1247 1205 1163 1121 1075 1026 977 927 876 S9X2B060D3PSAB 3-MEDIUM 1094 1047 1000 953 899 841 787 736 685 2-MED-LOW 941 880 819 758 690 629 571 505 443 1-LOW 825 769 704 634 567 499 426 368 316 Table 2. 2nd Stage Heating Table — Downflow CFM VS.2ND STAGE TEMPERATURE RISE CFM(CUDIC BEET PER MINUTE) MODEL 500 600 700 800 900 1 1000 1 1100 1200 1300 1400 1 1500 1 1600 1 1700 1 1800 1900 2000 2100 2200 2300 S9X2B060D3PSA6 63 1 58 1 52 1 48 1 44 1 41 1 37 Table 3. 1st Stage Heating Table— Downflow CFM VS.1ST STAGE TEMPERATURE RISE MODEL CFM(CUBIC FEET PER MINUTE) 400 1 500 1 600 1 700 1 800 1 900 1 1000 1 1100 1 1200 1300 1400 1 1500 1 1600 1 1700 1800 1900 1 2000 1 2100 S9X2B060D3PSAB 51 1 46 1 42 1 39 1 36 1 32 1 29 25 4 S9MBO60D3-SUB-1 B-EN l General Features NATURAL GAS MODELS ENERGY EFFICIENT OPERATION Central Heating furnace designs are certified by the Furnace is certified by the manufacturer to leak 1%or American Gas Association for both natural and L.P. less of nominal air conditioning CFM delivered when gas.Limit setting and rating data were established and pressurized to.5"water column with all inlets,outlets, approved under standard rating conditions using and drains sealed. American National Standards Institute standards. AIR DELIVERY SAFE OPERATION The variable speed blower motor has sufficient airflow The Integrated System Control is a solid state device for most heating and cooling requirements and will which continuously monitors for presence of flame switch from heating to cooling speeds on demand from when the system is in the heating mode of operation. room thermostat. Dual solenoid combination gas valve and regulator SECONDARY HEAT EXCHANGER provide additional safety. QUICK HEATING The S-Series furnace has a special type 29-4CTI stainless steel secondary heat exchanger to reclaim Durable,cycle tested,heavy gauge tubular stainless heat from flue gases which would normally be lost. steel primary heat exchanger quickly transfers heat STYLING to provide warm conditioned airto the structure.Low energy power vent blower,to increase efficiency and Heavy gauge steel and "wrap-around"cabinet provide a positive discharge of gas fumes to the construction is used in the cabinet with baked-on outside. enamel finish for strength and beauty.Every BURNERS orientation has at least two venting options.There are no knockouts on cabinet. Multipart Inshot burners will give years of quiet and FEATURES AND GENERAL OPERATION efficient service.All models can be converted to L.P. gas with LP conversion kit. The S-Series furnace utilizes a Silicon Nitride Hot INTEGRATED SYSTEM CONTROL Surface Ignition system,which eliminates the waste of a constant burning pilot.The integrated system control Exclusively designed operational program provides lights the main burners upon a demand for heat from total control of furnace limit sensors,blowers,gas the room thermostat.Complete front service access. valve,flame control and includes self diagnostics for a.Low energy power venter ease of service.Also contains dry contacts for EAC and HUM. b.Vent proving pressure switches. S9X2B060D3-SUB-1 B-EN 5 Features and Benefits UP TO 96.0%AFUE ON S9X2 FURNACE MODELS Last six errors stored Meets utility rebates Dry contact EAC and HUM connections Lowers utility bills All Molex connections;no spade terminals ELECTRICALLY EFFICIENT Low voltage labeled above and below Efficient airflow design reduces electrical energy use Rain shield over IFC keeps condensate off the control 34INCH TALL TUBULAR STAINLESS STEEL PRIMARY HEAT Lighter,easier to move and fit into tight spaces like EXCHANGER short basements or tight closets 29-4C STAINLESS STEEL SECONDARY HEAT EXCHANGER Works great with larger,high-efficiency coils Stainless steel is a more durable,corrosive-resistant No knockouts material than aluminumized steel 3—WAY MULTI-POISE/DEDICATED DOWNFLOW Integrated rail system for easy access if required 11 SKU's— Upflow/Horizontal Left/Horizontal Right Reduces or eliminates need for baffles 5 SKU's — Downf low VORTICA II BLOWER,DESIGNED EXCLUSIVELY Added application flexibility and reduction in FOR THE S-SERIES FURNACE specification errors Improved airflow efficiency AIRFLOW Durable,easy to clean,two piece housing At least 400 CFM/ton at 0.5 in.H2O external static Single piece belly band/motor arm assembly pressure;setup airflow options down to 290 CFM/ton Blower deck has full-length rails for easy removal and REGULATORY replacement,regardless of poise All models are airtight;1%or less air leakage as per THREE—WAY MULTI-POISE(UPFLOW, ASHRAE 193 HORIZONTAL LEFT AND RIGHT)PLUS DEDICATED Open vestibule design provides a full 34" high open DOWNFLOW vestibule Easier to specify DIMENSIONS Shipped ready to install(no conversion kits required) Widths are industry standard: 17.5",21",and 24.5" Every model has at least two venting options Depth remains approximately 28" When in horizontal,trap extends only about 2" Cabinet will be compatible with industry standard coils, Barbed fitting on trap at hose connection and on as well as,other accessories cabinet transition for hose has barbed fitting and INTEGRATED FURNACE CONTROL clamps at both ends for leak resistance. Setup/Status/Diagnostics/Digital Display Vent table improvements including longer vent No dip switches lengths;2"pipe can be used up to 100K 6 S9X2B060D3-SUB-1 B-EN (fFARDllngersoll Rand Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Car®, Ingersoll Rand®, Thermo King®and Trane®—work together to enhance the quality and comfort of air in homes and buildings;transport and protect food and perishables;and increase industrial productivity and efficiency.We are a global business committed to a world of sustainable progress and enduring results. CUPIngersoll Rand THERMO KING CE TAWE' ingersollrand.com Eta us Intertek Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. S9X2B060D3-SUB-IB-EN 12Jul201e Supersedes S9X2B060D3-SUB-IA-EN (April 2017) ©2016Ingersoll Rand